Upload
duongnhan
View
235
Download
4
Embed Size (px)
Citation preview
T4000 Core Router Interface Module Reference
Modified: 2017-05-02
Copyright © 2017, Juniper Networks, Inc.
Juniper Networks, Inc.1133 InnovationWaySunnyvale, California 94089USA408-745-2000www.juniper.net
Copyright © 2017, Juniper Networks, Inc. All rights reserved.
Juniper Networks, Junos, Steel-Belted Radius, NetScreen, and ScreenOS are registered trademarks of Juniper Networks, Inc. in the UnitedStates and other countries. The Juniper Networks Logo, the Junos logo, and JunosE are trademarks of Juniper Networks, Inc. All othertrademarks, service marks, registered trademarks, or registered service marks are the property of their respective owners.
Juniper Networks assumes no responsibility for any inaccuracies in this document. Juniper Networks reserves the right to change, modify,transfer, or otherwise revise this publication without notice.
T4000 Core Router Interface Module ReferenceCopyright © 2017, Juniper Networks, Inc.All rights reserved.
The information in this document is current as of the date on the title page.
YEAR 2000 NOTICE
Juniper Networks hardware and software products are Year 2000 compliant. Junos OS has no known time-related limitations through theyear 2038. However, the NTP application is known to have some difficulty in the year 2036.
ENDUSER LICENSE AGREEMENT
The Juniper Networks product that is the subject of this technical documentation consists of (or is intended for use with) Juniper Networkssoftware. Use of such software is subject to the terms and conditions of the End User License Agreement (“EULA”) posted athttp://www.juniper.net/support/eula.html. By downloading, installing or using such software, you agree to the terms and conditions ofthat EULA.
Copyright © 2017, Juniper Networks, Inc.ii
Table of Contents
About the Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xix
Documentation and Release Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xix
Supported Platforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xix
Documentation Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xix
Documentation Feedback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxi
Requesting Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxii
Self-Help Online Tools and Resources . . . . . . . . . . . . . . . . . . . . . . . . . . xxii
Opening a Case with JTAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxii
Part 1 Overview
Chapter 1 T4000 Interface Modules Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
T4000 PICs Supported . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
ATM IQ PICs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Channelized PICs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Gigabit Ethernet PICs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
10-Gigabit Ethernet PICs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
40-Gigabit Ethernet PICs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
100-Gigabit Ethernet PICs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Services PICs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
SONET/SDH PICs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
T4000 End-of-Life PICs Supported . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
T4000 PIC/FPC Compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
PIC/FPC Compatibility (Type 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
PIC/FPC Compatibility (Type 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
PIC/FPC Compatibility (Type 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
PIC/FPC Compatibility (Type 4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
PIC/FPC Compatibility (Type 5) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Chapter 2 Network Interface Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
SupportedNetwork InterfaceStandards byTransceiver for ACXSeries,MSeries,
MX Series, and T Series Routers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Fast Ethernet and Gigabit Ethernet Bidirectional SFP Optical Interface
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Fast Ethernet 100BASE-BX Bidirectional SFP Optical Interface
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Gigabit Ethernet 1000BASE-BX Bidirectional SFP (U 13/14 and D 14/13)
Optical Interface Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Gigabit Ethernet 1000BASE-BX Bidirectional SFP (U 13/15 and D 15/13)
Optical Interface Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
iiiCopyright © 2017, Juniper Networks, Inc.
Gigabit Ethernet 1000BASE-BX Bidirectional SFP (40 U 13/15 and D 15/13)
Optical Interface Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Gigabit Ethernet 1000BASE Optical Interface Specifications . . . . . . . . . . . . . . . . 30
Gigabit Ethernet 1000BASE-SX Optical Interface Specifications . . . . . . . . . . 31
Gigabit Ethernet 1000BASE-LX Optical Interface Specifications . . . . . . . . . . 31
Gigabit Ethernet 1000BASE-LX10 Optical Interface Specifications . . . . . . . . 32
Gigabit Ethernet 1000BASE-EX Optical Interface Specifications . . . . . . . . . 32
Gigabit Ethernet 1000BASE-LH Optical Interface Specifications . . . . . . . . . 33
Gigabit Ethernet 1000BASE-T Copper Interface Specifications . . . . . . . . . . . . . . 34
10-Gigabit Ethernet 10GBASE Optical Interface Specifications . . . . . . . . . . . . . . . 34
10GBASE-LRM Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
10GBASE-S Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
10GBASE-L Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
10GBASE-E Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
10GBASE-Z Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
10-Gigabit Ethernet DWDM OTN Optical Interface Specifications . . . . . . . . . . . . 39
10-Gigabit Ethernet DWDMOTNOptical Interface Specifications . . . . . . . . . 39
10-Gigabit Ethernet DWDMOTN SupportedWavelengths . . . . . . . . . . . . . . . 42
PC-1XGE-DWDM-OTNOptical Signal-to-Noise Ratio (OSNR)
Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
10-Gigabit Ethernet DWDM Transceiver Wavelengths . . . . . . . . . . . . . . . . . . . . . . 44
40-Gigabit Ethernet 40GBASE-R Optical Interface Specifications . . . . . . . . . . . 46
40GBASE-SR4 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
40GBASE-LX4 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
40GBASE-LR4 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
40GBASE-ER4 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
100-Gigabit Ethernet 100GBASE-R Optical Interface Specifications . . . . . . . . . . 49
100GBASE-SR10 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
100GBASE-SR4 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
100GBASE-LR4 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
100GBASE-ER4 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Juniper Networks Specifications for CFP-100GBASE-ZR . . . . . . . . . . . . . . . . 52
SONET/SDH OC3/STM1 Optical Interface Specifications . . . . . . . . . . . . . . . . . . . 53
SONET/SDH OC3/STM1 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
SONET/SDH OC3/STM1 Intermediate Reach (IR-1) Specifications . . . . . . . . 54
SONET/SDH OC3/STM1 Long Reach (LR-1) Specifications . . . . . . . . . . . . . . 54
SONET/SDH OC12/STM4 Optical Interface Specifications . . . . . . . . . . . . . . . . . . 55
SONET/SDH OC12/STM4 Short Reach (SR-1) Specifications . . . . . . . . . . . . 55
SONET/SDH OC12/STM4 Intermediate Reach (IR-1) Specifications . . . . . . . 56
SONET/SDH OC12/STM4 Long Reach (LR-1) Specifications . . . . . . . . . . . . . 56
SONET/SDH OC12/STM4 Long Reach (LR-2) Specifications . . . . . . . . . . . . . 57
SONET/SDH OC48/STM16 Optical Interface Specifications . . . . . . . . . . . . . . . . . 57
SONET/SDH OC48/STM16 Short Reach (SR-1) Specifications . . . . . . . . . . . 58
SONET/SDH OC48/STM16 Intermediate Reach (IR-1) Specifications . . . . . 58
SONET/SDH OC48/STM16 Long Reach (LR-1) Specifications . . . . . . . . . . . 59
SONET/SDH OC48/STM16 Long Reach (LR-2) Specifications . . . . . . . . . . . 59
SONET/SDH OC192/STM64 Optical Interface Specifications . . . . . . . . . . . . . . . 60
SONET/SDH OC192/STM64 Very Short Reach (VSR) . . . . . . . . . . . . . . . . . . 60
SONET/SDH OC192/STM64 Short Reach (SR-1) . . . . . . . . . . . . . . . . . . . . . . 61
Copyright © 2017, Juniper Networks, Inc.iv
T4000 Core Router Interface Module Reference
SONET/SDH OC192/STM64 Short Reach (SR-2) . . . . . . . . . . . . . . . . . . . . . . 61
SONET/SDH OC192/STM64 Intermediate Reach (IR-2) . . . . . . . . . . . . . . . . 62
SONET/SDH OC192/STM64 Long reach (LR-1) . . . . . . . . . . . . . . . . . . . . . . . 62
SONET/SDH OC192/STM64 Long reach (LR-2) . . . . . . . . . . . . . . . . . . . . . . . 63
SONET/SDH OC768/STM256 Optical Interface Specifications . . . . . . . . . . . . . . 63
Part 2 PIC Descriptions
Chapter 3 ATM2 IQ PIC Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
ATM2 OC12/STM4 IQ PIC (T4000 Router) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Software Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Hardware Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Software Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Cables and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Alarms, Errors, and Events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Chapter 4 Channelized PIC Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Channelized DS3 IQ PIC (T4000 Router) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Software Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Hardware Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Software Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Cables and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Alarms, Errors, and Events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Instrumentation (counters) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Channelized STM1 IQ PIC (T4000 Router) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Channelized OC3 IQ PIC (T4000 Router) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
Chapter 5 Channelized Enhanced IQ (IQE) PIC Descriptions . . . . . . . . . . . . . . . . . . . . . 81
Channelized DS3/E3 Enhanced IQ (IQE) PIC (T4000 Router) . . . . . . . . . . . . . . . 82
Channelized E1/T1 Enhanced IQ (IQE) PIC (T4000 Router) . . . . . . . . . . . . . . . . . 85
Channelized OC3/STM1 Enhanced IQ (IQE) PIC with SFP (T4000 Router) . . . . 88
Channelized OC12/STM4 Enhanced IQ (IQE) PICs with SFP (T4000 Router) . . . 92
Software Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
Hardware Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
Software Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
Cables and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
Alarms, Errors, and Events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
Instrumentation (counters) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
Channelized OC48/STM16 Enhanced IQ (IQE) PIC with SFP (T4000 Router) . . 99
Software Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
Hardware Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
Software Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Cables and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
Alarms, Errors, and Events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
Instrumentation (counters) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
vCopyright © 2017, Juniper Networks, Inc.
Table of Contents
PICsSupported in theFourthSlotofT640-FPC2-EandT640-FPC2-E2with
Type 2 IQE PICs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
Chapter 6 DS3 and E3 PIC Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
DS3/E3 Enhanced IQ (IQE) PIC (T4000 Router) . . . . . . . . . . . . . . . . . . . . . . . . . 107
Chapter 7 Fast Ethernet PIC Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
Fast Ethernet PIC (T4000 Router) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
Chapter 8 Gigabit Ethernet PIC Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
Gigabit Ethernet PICs with SFP (T4000 Router) . . . . . . . . . . . . . . . . . . . . . . . . . . 113
Software Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
Hardware Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
Software Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
Cables and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116
Gigabit Ethernet IQ PIC with SFP (T4000 Router) . . . . . . . . . . . . . . . . . . . . . . . . 116
Software Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
Hardware Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
Software Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
Cables and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
Gigabit Ethernet IQ PIC with SFP LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118
Gigabit Ethernet IQ2 PICs with SFP (T4000 Router) . . . . . . . . . . . . . . . . . . . . . . 119
Software Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
Hardware Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
Software Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
Cables and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
Gigabit Ethernet Enhanced IQ2 (IQ2E) PIC with SFP (T4000 Router) . . . . . . . . 122
Software Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
Hardware Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
Software Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
Cables and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124
LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124
Chapter 9 10-Gigabit Ethernet PIC Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127
10-Gigabit Ethernet PIC with XENPAK (T4000 Router) . . . . . . . . . . . . . . . . . . . . 127
Software Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128
Hardware Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128
Software Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128
Cables and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128
LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129
10-Gigabit Ethernet IQ2 PIC with XFP (T4000 Router) . . . . . . . . . . . . . . . . . . . . 130
Software Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130
Hardware Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130
Software Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131
Cables and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131
LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132
Copyright © 2017, Juniper Networks, Inc.vi
T4000 Core Router Interface Module Reference
10-Gigabit Ethernet IQ2E PIC with XFP (T4000 Router) . . . . . . . . . . . . . . . . . . . 133
Software Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
Hardware Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
Software Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134
Cables and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135
LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135
10-Gigabit Ethernet LAN/WAN PIC with SFP+ (T4000 Router) . . . . . . . . . . . . . 136
Software Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136
Hardware Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136
Software Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137
Cables and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139
Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139
10-Gigabit Ethernet LAN/WAN PIC with Oversubscription and SFP+ (T4000
Router) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140
Software Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140
Hardware Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141
Software Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141
Cables and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145
Alarms, Errors, and Events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146
10-Gigabit Ethernet LAN/WAN PIC with XFP (T4000 Router) . . . . . . . . . . . . . . 147
Software Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147
Hardware Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147
Software Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148
Cables and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148
LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149
Alarms, Errors, and Events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149
Chapter 10 40-Gigabit Ethernet PIC Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151
40-Gigabit Ethernet PIC with CFP (T4000 Router) . . . . . . . . . . . . . . . . . . . . . . . 151
Software Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151
Hardware Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152
Software Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152
Cables and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153
LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153
Alarms, Errors, and Events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153
Chapter 11 100-Gigabit Ethernet PIC Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155
100-Gigabit Ethernet PIC with CFP (T4000 Router) . . . . . . . . . . . . . . . . . . . . . . 155
Software Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155
Hardware Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156
Software Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156
Cables and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159
LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160
Alarms, Errors, and Events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161
viiCopyright © 2017, Juniper Networks, Inc.
Table of Contents
Chapter 12 Services PIC Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163
MultiServices PICs (T4000 Router) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163
Software Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 164
Hardware Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 164
Software Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165
LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 166
Tunnel Services PICs (T4000 Router) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167
Software Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167
Hardware Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167
Software Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167
LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168
Chapter 13 SONET/SDH PIC Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169
SONET/SDH OC3/STM1 (Multi-Rate) PICs with SFP (T4000 Router) . . . . . . . . 169
Software Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170
Hardware Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170
Software Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170
Cables and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171
LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 172
Alarms, Errors, and Events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 172
SONET/SDH OC12/STM4 (Multi-Rate) PICs with SFP (T4000 Router) . . . . . . . 174
Software Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 174
Hardware Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 174
Software Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175
Cables and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 176
LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 176
Alarms, Errors, and Events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177
SONET/SDH OC48c/STM16 PIC with SFP (T4000 Router) . . . . . . . . . . . . . . . . 178
Software Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178
Hardware Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179
Software Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179
Cables and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179
LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180
Alarms, Errors, and Events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180
SONET/SDHOC48/STM16 Enhanced IQ (IQE) PIC with SFP (T4000
Router) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182
Software Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182
Hardware Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182
Software Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183
Cables and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183
LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 184
Alarms, Errors, and Events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 184
SONET/SDH OC48/STM16 (Multi-Rate) PIC with SFP (T4000 Router) . . . . . . 186
Software Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 186
Hardware Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 186
Software Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187
Cables and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187
LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 188
Alarms, Errors, and Events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 188
Copyright © 2017, Juniper Networks, Inc.viii
T4000 Core Router Interface Module Reference
SONET/SDH OC192/STM64 PICs with XFP (T4000 Router) . . . . . . . . . . . . . . . 190
Software Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191
Hardware Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191
Software Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191
Cables and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192
LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192
Alarms, Errors, and Events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193
SONET/SDH OC768c/STM256 PIC (T4000 Router) . . . . . . . . . . . . . . . . . . . . . . 195
Software Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195
Hardware Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195
Software Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 196
Cables and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 196
LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197
Alarms, Errors, and Events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197
Chapter 14 End-of-Life PIC Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 199
10-Gigabit Ethernet DWDMOTN EOL PIC (T4000 Router) . . . . . . . . . . . . . . . . . 199
Software Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 199
Hardware Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200
Software Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200
Cables and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200
LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201
SONET/SDH OC12c/STM4 EOL PIC (T4000 Router) . . . . . . . . . . . . . . . . . . . . . 201
Software Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201
Hardware Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202
Software Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202
Cables and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202
LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203
Alarms, Errors, and Events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203
SONET/SDH OC48c/STM16 EOL PICs (T4000 Router) . . . . . . . . . . . . . . . . . . . 205
Software Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205
Hardware Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205
Software Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 206
Cables and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 206
LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 207
Alarms, Errors, and Events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 207
SONET/SDH OC48c/STM16 EOL PIC with SFP (T4000 Router) . . . . . . . . . . . . 209
Software Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 209
Hardware Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 209
Software Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210
Cables and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210
LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211
Alarms, Errors, and Events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211
SONET/SDH OC192/STM64 EOL PIC (T4000 Router) . . . . . . . . . . . . . . . . . . . . 212
Software Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213
Hardware Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213
Software Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213
Cables and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 214
LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 214
ixCopyright © 2017, Juniper Networks, Inc.
Table of Contents
Alarms, Errors, and Events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 214
Copyright © 2017, Juniper Networks, Inc.x
T4000 Core Router Interface Module Reference
List of Figures
Part 2 PIC Descriptions
Chapter 3 ATM2 IQ PIC Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Figure 1: 2-Port ATM2 OC12/STM4 IQ PIC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Chapter 5 Channelized Enhanced IQ (IQE) PIC Descriptions . . . . . . . . . . . . . . . . . . . . . 81
Figure 2: 1-Port IQE PIC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Figure 3: 4-Port IQE PIC (Type 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Figure 4: 4-Port IQE PIC (Type 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Chapter 8 Gigabit Ethernet PIC Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
Figure 5: 2-Port Gigabit Ethernet PIC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
Figure 6: 4-Port Gigabit Ethernet PIC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
Figure 7: 2-Port Gigabit Ethernet IQ PIC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116
Figure 8: 4-Port Gigabit Ethernet IQ2 PIC (Type 1) . . . . . . . . . . . . . . . . . . . . . . . . . 119
Figure 9: 8-Port Gigabit Ethernet IQ2 PIC (Type 2) . . . . . . . . . . . . . . . . . . . . . . . . 119
Figure 10: 8-Port Gigabit Ethernet IQ2E PIC (Type 3) . . . . . . . . . . . . . . . . . . . . . . 122
Chapter 9 10-Gigabit Ethernet PIC Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127
Figure 11: 10-Port Type 4 PIC with Oversubscription . . . . . . . . . . . . . . . . . . . . . . . 140
Figure 12: 24-Port Type 5 PIC with Oversubscription . . . . . . . . . . . . . . . . . . . . . . 140
Chapter 11 100-Gigabit Ethernet PIC Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155
Figure 13: Type 5 100-Gigabit Ethernet PIC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155
Chapter 12 Services PIC Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163
Figure 14: MultiServices 400 PIC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163
Figure 15: MultiServices 500 PIC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 164
Chapter 13 SONET/SDH PIC Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169
Figure 16: SONET/SDH OC3/STM1 (Multi-Rate) PIC (Type 1) . . . . . . . . . . . . . . . 169
Figure 17: SONET/SDH OC3/STM1 (Multi-Rate) PIC (Type 2) . . . . . . . . . . . . . . . 169
Figure 18: 1-Port SONET/SDH OC12/STM4 (Multi-Rate) PIC . . . . . . . . . . . . . . . . 174
Figure 19: 4-Port SONET/SDH OC12/STM4 (Multi-Rate) PIC . . . . . . . . . . . . . . . . 174
Figure 20: 1-Port SONET/SDH OC192/STM64 PIC . . . . . . . . . . . . . . . . . . . . . . . . 190
Figure 21: 4-Port SONET/SDH OC192/STM64 PIC . . . . . . . . . . . . . . . . . . . . . . . . 190
Chapter 14 End-of-Life PIC Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 199
Figure 22: 4-Port SONET/SDH OC12c/STM4 PIC . . . . . . . . . . . . . . . . . . . . . . . . . 201
Figure 23: 1-Port SONET/SDH OC48c/STM16 PIC . . . . . . . . . . . . . . . . . . . . . . . . 205
Figure 24: 4-Port SONET/SDH OC48c/STM16 PIC . . . . . . . . . . . . . . . . . . . . . . . 205
xiCopyright © 2017, Juniper Networks, Inc.
Copyright © 2017, Juniper Networks, Inc.xii
T4000 Core Router Interface Module Reference
List of Tables
About the Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xix
Table 1: Notice Icons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xx
Table 2: Text and Syntax Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xx
Part 1 Overview
Chapter 1 T4000 Interface Modules Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Table 3: ATM IQ PICs Supported in the T4000 Router . . . . . . . . . . . . . . . . . . . . . . . 3
Table 4: Channelized PICs Supported in the T4000 Router . . . . . . . . . . . . . . . . . . 4
Table 5: Gigabit Ethernet PICs Supported in the T4000 Router . . . . . . . . . . . . . . . 4
Table 6: 10-Gigabit Ethernet PICs Supported in the T4000 Router . . . . . . . . . . . . 5
Table 7: 40-Gigabit Ethernet PICs Supported in the T4000 Router . . . . . . . . . . . . 5
Table 8: 100-Gigabit Ethernet PICs Supported in the T4000 Router . . . . . . . . . . . 6
Table 9: Services PICs Supported in the T4000 Router . . . . . . . . . . . . . . . . . . . . . . 6
Table 10: SONET/SDH PICs Supported in the T4000 Router . . . . . . . . . . . . . . . . . 6
Table 11: End-of-Life PICs Supported in the T4000 Router . . . . . . . . . . . . . . . . . . . 8
Table 12: T4000 PIC/FPC Compatibility Type 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Table 13: T4000 PIC/FPC Compatibility Type 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Table 14: T4000 PIC/FPC Compatibility Type 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Table 15: T4000 PIC/FPC Compatibility Type 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Table 16: T4000 PIC/FPC Compatibility Type 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Chapter 2 Network Interface Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Table 17: Supported Ethernet Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Table 18: Supported SONET Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Table 19: Fast Ethernet 100BASE-BX Bidirectional SFP Optical Interface
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Table20:Gigabit Ethernet 1000BASE-BXBidirectionalSFP(U 13/14andD 14/13)
Optical Interface Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Table21:Gigabit Ethernet 1000BASE-BXBidirectionalSFP(U 13/15andD 15/13)
Optical Interface Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Table 22: Gigabit Ethernet 1000BASE-BX Bidirectional SFP (40 U 13/15 and D
15/13) Optical Interface Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Table 23: Gigabit Ethernet 1000BASE-SX Optical Interface Specifications . . . . . . 31
Table 24: Gigabit Ethernet 1000BASE-LX Optical Interface Specifications . . . . . . 31
Table 25: Gigabit Ethernet 1000BASE-LX10 Optical Interface Specifications . . . 32
Table 26: Gigabit Ethernet 1000BASE-EX Optical Interface Specifications . . . . . 33
Table 27: Gigabit Ethernet 1000BASE-LH Optical Interface Specifications . . . . . 33
Table 28: 1000BASE-T Copper Interface Specifications . . . . . . . . . . . . . . . . . . . . 34
Table 29: 10GBASE-LRM Optical Interface Specifications . . . . . . . . . . . . . . . . . . . 35
xiiiCopyright © 2017, Juniper Networks, Inc.
Table 30: 10GBASE-S (10GBASE-SR and 10GBASE-SW) Optical Interface
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Table 31: 10GBASE-L (10GBASE-LR and 10GBASE-LW) Optical Interface
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Table 32: 10GBASE-E (10GBASE-ER and 10GBASE-EW) Optical Interface
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Table 33: 10GBASE-Z (10GBASE-ZR and 10GBASE-ZW) Optical Interface
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Table 34: 10-Gigabit Ethernet DWDM OTN Optical Interface Specifications . . . . 40
Table 35: 10-Gigabit Ethernet DWDM OTN Supported Wavelengths . . . . . . . . . . 43
Table 36: PC-1XGE-DWDM-OTNOptical Signal-to-Noise Ratio (OSNR)
Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Table37:ProgrammableWavelengthsSupportedby 10-GigabitEthernetDWDM
Transceivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Table 38: 40GBASE-SR4 Optical Interface Specifications . . . . . . . . . . . . . . . . . . 46
Table 39: 40GBASE-LX4 Optical Interface Specifications . . . . . . . . . . . . . . . . . . . 47
Table 40: 40GBASE-LR4 Optical Interface Specifications . . . . . . . . . . . . . . . . . . 48
Table 41: 40GBASE-ER4 Optical Interface Specifications . . . . . . . . . . . . . . . . . . . 49
Table 42: 100GBASE-SR10 Optical Interface Specifications . . . . . . . . . . . . . . . . . 50
Table 43: 100GBASE-SR4 Optical Interface Specifications . . . . . . . . . . . . . . . . . 50
Table 44: 100GBASE-LR4 Optical Interface Specifications . . . . . . . . . . . . . . . . . . 51
Table 45: 100GBASE-ER4 Optical Interface Specifications . . . . . . . . . . . . . . . . . . 51
Table 46: Juniper Networks Optical Interface Specifications for
CFP-100GBASE-ZR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Table 47: SONET/SDHOC3/STM1 Multimode Optical Interface
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Table 48: SONET/SDHOC3/STM1 Intermediate Reach Optical Interface
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Table 49: SONET/SDHOC3/STM1 Long Reach -1 Optical Interface
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Table 50: SONET/SDHOC12/STM4 Short Reach (SR-1) Optical Interface
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Table 51: SONET/SDHOC12/STM4 Intermediate Reach (IR-1) Optical Interface
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Table 52: SONET/SDHOC12/STM4 Long Reach (LR-1) Optical Interface
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Table 53: SONET/SDHOC12/STM4 Long Reach (LR-2) Optical Interface
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Table 54: SONET/SDHOC48/STM16 Short Reach (SR-1) Optical Interface
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Table55:SONET/SDHOC48/STM16 IntermediateReach(IR-1)Optical Interface
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Table 56: SONET/SDHOC48/STM16 Long Reach (LR-1) Optical Interface
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Table 57: SONET/SDHOC48/STM16 Long Reach (LR-2) Optical Interface
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Table 58: SONET/SDHOC192/STM64 Very Short Reach (VSR 1) Optical
Interface Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Copyright © 2017, Juniper Networks, Inc.xiv
T4000 Core Router Interface Module Reference
Table 59: SONET/SDHOC192/STM64 Short Reach (SR-1) Optical Interface
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Table 60: SONET/SDHOC192/STM64 Short Reach (SR-2) Optical Interface
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Table 61: SONET/SDHOC192/STM64 Intermediate Reach (IR-2) Optical
Interface Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Table 62: SONET/SDHOC192/STM64 Long Reach (LR-1) Optical Interface
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Table 63: SONET/SDHOC192/STM64 Long Reach (LR-2) Optical Interface
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Table 64: SONET/SDHOC768/STM256 Short Reach (SR-1) Optical Interface
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Part 2 PIC Descriptions
Chapter 3 ATM2 IQ PIC Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Table 65: Software Features Supported . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Table 66: ATM2 OC12/STM4 IQ PIC LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Chapter 4 Channelized PIC Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Table 67: Software Features Supported . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Table 68: Channelized DS3 IQ PIC LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Chapter 5 Channelized Enhanced IQ (IQE) PIC Descriptions . . . . . . . . . . . . . . . . . . . . . 81
Table 69: Software Features Supported . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
Table 70: Channelized OC12/STM4 Enhanced IQ (IQE) PICs with SFP LEDs . . . . 96
Table 71: Software Features Supported . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Table 72: Channelized OC48/STM16 Enhanced IQ (IQE) PIC with SFP LEDs . . . 102
Table 73: PICs Supported in Fourth Slot of T640-FPC2-E and T640-FPC2-E2
with Type 2 IQE PICs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
Chapter 8 Gigabit Ethernet PIC Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
Table 74: Software Features Supported . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
Table 75: Gigabit Ethernet PICs with SFP LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . 116
Table 76: Software Features Supported . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
Table 77: LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118
Table 78: Software Features Supported . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
Table 79: Gigabit Ethernet IQ2 PICs with SFP LEDs . . . . . . . . . . . . . . . . . . . . . . . . 121
Table 80: Software Features Supported . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
Table 81: Gigabit Ethernet Enhanced IQ2 (IQ2E) PIC with SFP LEDs . . . . . . . . . . 124
Chapter 9 10-Gigabit Ethernet PIC Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127
Table 82: Software Features Supported . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128
Table 83: 10-Gigabit Ethernet PIC with XENPAK LEDs . . . . . . . . . . . . . . . . . . . . . 129
Table 84: Software Features Supported . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131
Table 85: 10-Gigabit Ethernet IQ2 PIC with XFP LEDs . . . . . . . . . . . . . . . . . . . . . . 132
Table 86: Software Features Supported . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134
Table 87: 10-Gigabit Ethernet IQ2E PIC with XFP LEDs . . . . . . . . . . . . . . . . . . . . . 135
Table 88: Software Features Supported . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137
Table 89: 10-Gigabit Ethernet LAN/WAN PIC with SFP+ LEDs . . . . . . . . . . . . . . 139
xvCopyright © 2017, Juniper Networks, Inc.
List of Tables
Table 90: Software Features Supported on 10-Port Type 4 PIC with Over
subscription . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141
Table 91: Software Features Supported on 24-Port Type 5 PIC with
Oversubscription . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142
Table 92: 10-Gigabit Ethernet LAN/WAN PIC with Oversubscription and SFP+
LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145
Table 93: Software Features Supported . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148
Table 94: 10-Gigabit Ethernet LAN/WAN PIC with XFP LEDs . . . . . . . . . . . . . . . 149
Chapter 10 40-Gigabit Ethernet PIC Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151
Table 95: Software Features Supported . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152
Table 96: 40-Gigabit Ethernet PIC with CFP LEDs . . . . . . . . . . . . . . . . . . . . . . . . 153
Chapter 11 100-Gigabit Ethernet PIC Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155
Table 97: Software Features Supported on Type 5 PIC . . . . . . . . . . . . . . . . . . . . 156
Table 98: Software Features Supported on Type 4 PIC . . . . . . . . . . . . . . . . . . . . 158
Table 99: Type 5 LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160
Table 100: Type 4 PIC LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160
Chapter 12 Services PIC Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163
Table 101: MultiServices PICs Software Features Supported on the T4000
Router . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165
Table 102: MultiServices PIC LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 166
Table 103: Tunnel Services PIC LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168
Chapter 13 SONET/SDH PIC Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169
Table 104: Software Features Supported . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170
Table 105: SONET/SDH OC3/STM1 (Multi-Rate) PIC with SFP LEDs . . . . . . . . . . 172
Table 106: Software Features Supported . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175
Table 107: SONET/SDH OC12/STM4 (Multi-Rate) PICs with SFP LEDs . . . . . . . . 176
Table 108: Software Features Supported . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179
Table 109: SONET/SDH OC48c/STM16 PIC with SFP LEDs . . . . . . . . . . . . . . . . 180
Table 110: Software Features Supported . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183
Table 111: SONET/SDH OC48/STM16 Enhanced IQ (IQE) PIC with SFP LEDs . . . 184
Table 112: Software Features Supported . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187
Table 113: SONET/SDH OC48/STM16 (Multi-Rate) PIC with SFP LEDs . . . . . . . 188
Table 114: Software Features Supported . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191
Table 115: 1-Port SONET/SDH OC192/STM64 PIC LEDs . . . . . . . . . . . . . . . . . . . . 192
Table 116: 4-Port SONET/SDH OC192/STM64 PIC LEDs . . . . . . . . . . . . . . . . . . . 193
Table 117: Software Features Supported . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 196
Table 118: SONET/SDH OC768c/STM256 PIC LEDs . . . . . . . . . . . . . . . . . . . . . . . 197
Chapter 14 End-of-Life PIC Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 199
Table 119: Software Features Supported . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200
Table 120: 10-Gigabit Ethernet DWDM OTN EOL PIC LEDs . . . . . . . . . . . . . . . . . 201
Table 121: Software Features Supported . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202
Table 122: SONET/SDH OC12c/STM4 EOL PIC LEDs . . . . . . . . . . . . . . . . . . . . . . 203
Table 123: Software Features Supported . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 206
Table 124: SONET/SDH OC48c/STM16 EOL PICs LEDs . . . . . . . . . . . . . . . . . . . . 207
Table 125: Software Features Supported . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210
Table 126: SONET/SDH OC48c/STM16 EOL PIC with SFP LEDs . . . . . . . . . . . . . . 211
Copyright © 2017, Juniper Networks, Inc.xvi
T4000 Core Router Interface Module Reference
Table 127: Software Features Supported . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213
Table 128: SONET/SDH OC192/STM64 EOL PIC LEDs . . . . . . . . . . . . . . . . . . . . . 214
xviiCopyright © 2017, Juniper Networks, Inc.
List of Tables
Copyright © 2017, Juniper Networks, Inc.xviii
T4000 Core Router Interface Module Reference
About the Documentation
• Documentation and Release Notes on page xix
• Supported Platforms on page xix
• Documentation Conventions on page xix
• Documentation Feedback on page xxi
• Requesting Technical Support on page xxii
Documentation and Release Notes
To obtain the most current version of all Juniper Networks®technical documentation,
see the product documentation page on the Juniper Networks website at
http://www.juniper.net/techpubs/.
If the information in the latest release notes differs from the information in the
documentation, follow the product Release Notes.
Juniper Networks Books publishes books by Juniper Networks engineers and subject
matter experts. These books go beyond the technical documentation to explore the
nuances of network architecture, deployment, and administration. The current list can
be viewed at http://www.juniper.net/books.
Supported Platforms
For the features described in this document, the following platforms are supported:
• T4000
Documentation Conventions
Table 1 on page xx defines notice icons used in this guide.
xixCopyright © 2017, Juniper Networks, Inc.
Table 1: Notice Icons
DescriptionMeaningIcon
Indicates important features or instructions.Informational note
Indicates a situation that might result in loss of data or hardware damage.Caution
Alerts you to the risk of personal injury or death.Warning
Alerts you to the risk of personal injury from a laser.Laser warning
Indicates helpful information.Tip
Alerts you to a recommended use or implementation.Best practice
Table 2 on page xx defines the text and syntax conventions used in this guide.
Table 2: Text and Syntax Conventions
ExamplesDescriptionConvention
To enter configuration mode, type theconfigure command:
user@host> configure
Represents text that you type.Bold text like this
user@host> show chassis alarms
No alarms currently active
Represents output that appears on theterminal screen.
Fixed-width text like this
• A policy term is a named structurethat defines match conditions andactions.
• Junos OS CLI User Guide
• RFC 1997,BGPCommunities Attribute
• Introduces or emphasizes importantnew terms.
• Identifies guide names.
• Identifies RFC and Internet draft titles.
Italic text like this
Configure themachine’s domain name:
[edit]root@# set system domain-namedomain-name
Represents variables (options for whichyou substitute a value) in commands orconfiguration statements.
Italic text like this
Copyright © 2017, Juniper Networks, Inc.xx
T4000 Core Router Interface Module Reference
Table 2: Text and Syntax Conventions (continued)
ExamplesDescriptionConvention
• To configure a stub area, include thestub statement at the [edit protocolsospf area area-id] hierarchy level.
• Theconsoleport is labeledCONSOLE.
Represents names of configurationstatements, commands, files, anddirectories; configurationhierarchy levels;or labels on routing platformcomponents.
Text like this
stub <default-metricmetric>;Encloses optional keywords or variables.< > (angle brackets)
broadcast | multicast
(string1 | string2 | string3)
Indicates a choice between themutuallyexclusive keywords or variables on eitherside of the symbol. The set of choices isoften enclosed in parentheses for clarity.
| (pipe symbol)
rsvp { # Required for dynamicMPLS onlyIndicates a comment specified on thesame lineas theconfiguration statementto which it applies.
# (pound sign)
community namemembers [community-ids ]
Encloses a variable for which you cansubstitute one or more values.
[ ] (square brackets)
[edit]routing-options {static {route default {nexthop address;retain;
}}
}
Identifies a level in the configurationhierarchy.
Indention and braces ( { } )
Identifies a leaf statement at aconfiguration hierarchy level.
; (semicolon)
GUI Conventions
• In the Logical Interfaces box, selectAll Interfaces.
• To cancel the configuration, clickCancel.
Representsgraphicaluser interface(GUI)items you click or select.
Bold text like this
In the configuration editor hierarchy,select Protocols>Ospf.
Separates levels in a hierarchy of menuselections.
> (bold right angle bracket)
Documentation Feedback
We encourage you to provide feedback, comments, and suggestions so that we can
improve the documentation. You can provide feedback by using either of the following
methods:
• Online feedback rating system—On any page of the Juniper Networks TechLibrary site
athttp://www.juniper.net/techpubs/index.html, simply click the stars to rate thecontent,
and use the pop-up form to provide us with information about your experience.
Alternately, you can use the online feedback form at
http://www.juniper.net/techpubs/feedback/.
xxiCopyright © 2017, Juniper Networks, Inc.
About the Documentation
• E-mail—Sendyourcommentsto [email protected]. Includethedocument
or topic name, URL or page number, and software version (if applicable).
Requesting Technical Support
Technical product support is available through the JuniperNetworksTechnicalAssistance
Center (JTAC). If you are a customer with an active J-Care or Partner Support Service
support contract, or are covered under warranty, and need post-sales technical support,
you can access our tools and resources online or open a case with JTAC.
• JTAC policies—For a complete understanding of our JTAC procedures and policies,
review the JTAC User Guide located at
http://www.juniper.net/us/en/local/pdf/resource-guides/7100059-en.pdf.
• Product warranties—For product warranty information, visit
http://www.juniper.net/support/warranty/.
• JTAC hours of operation—The JTAC centers have resources available 24 hours a day,
7 days a week, 365 days a year.
Self-Help Online Tools and Resources
For quick and easy problem resolution, Juniper Networks has designed an online
self-service portal called the Customer Support Center (CSC) that provides youwith the
following features:
• Find CSC offerings: http://www.juniper.net/customers/support/
• Search for known bugs: http://www2.juniper.net/kb/
• Find product documentation: http://www.juniper.net/techpubs/
• Find solutions and answer questions using our Knowledge Base: http://kb.juniper.net/
• Download the latest versions of software and review release notes:
http://www.juniper.net/customers/csc/software/
• Search technical bulletins for relevant hardware and software notifications:
http://kb.juniper.net/InfoCenter/
• Join and participate in the Juniper Networks Community Forum:
http://www.juniper.net/company/communities/
• Open a case online in the CSC Case Management tool: http://www.juniper.net/cm/
Toverify serviceentitlementbyproduct serial number, useourSerialNumberEntitlement
(SNE) Tool: https://tools.juniper.net/SerialNumberEntitlementSearch/
Opening a Casewith JTAC
You can open a case with JTAC on theWeb or by telephone.
• Use the Case Management tool in the CSC at http://www.juniper.net/cm/.
• Call 1-888-314-JTAC (1-888-314-5822 toll-free in the USA, Canada, and Mexico).
Copyright © 2017, Juniper Networks, Inc.xxii
T4000 Core Router Interface Module Reference
For international or direct-dial options in countries without toll-free numbers, see
http://www.juniper.net/support/requesting-support.html.
xxiiiCopyright © 2017, Juniper Networks, Inc.
About the Documentation
Copyright © 2017, Juniper Networks, Inc.xxiv
T4000 Core Router Interface Module Reference
PART 1
Overview
• T4000 Interface Modules Support on page 3
• Network Interface Specifications on page 17
1Copyright © 2017, Juniper Networks, Inc.
Copyright © 2017, Juniper Networks, Inc.2
T4000 Core Router Interface Module Reference
CHAPTER 1
T4000 Interface Modules Support
• T4000 PICs Supported on page 3
• T4000 End-of-Life PICs Supported on page 7
• T4000 PIC/FPC Compatibility on page 8
T4000 PICs Supported
Table 3 on page 3 through Table 10 on page 6 list the PICs supported by the T4000
routerbyPIC family. TheFirst JunosOSReleaseSupport column indicates the first release
the PIC was supported on the T4000 router.
• ATM IQ PICs on page 3
• Channelized PICs on page 3
• Gigabit Ethernet PICs on page 4
• 10-Gigabit Ethernet PICs on page 4
• 40-Gigabit Ethernet PICs on page 5
• 100-Gigabit Ethernet PICs on page 5
• Services PICs on page 6
• SONET/SDH PICs on page 6
ATM IQ PICs
Table 3 on page 3 lists the ATM IQ PICs supported by the T4000 router.
Table 3: ATM IQ PICs Supported in the T4000 Router
First Junos OSReleaseSupportConnectorsModel NumberPortsPIC Family and Type
12.2R2Optical: SCPB-2OC12-ATM2-SMIR2“ATM2 OC12/STM4 IQ PIC(T4000 Router)” on page 67
Channelized PICs
Table 4 on page 4 lists the Channelized PICs supported by the T4000 router.
3Copyright © 2017, Juniper Networks, Inc.
Table 4: Channelized PICs Supported in the T4000 Router
First Junos OSReleaseSupportConnectorsModel NumberPortsPIC Family and Type
12.1R2CoaxialPB-4CHDS3-QPP4“Channelized DS3 IQ PIC(T4000 Router)” on page 73
12.1.R2CoaxialPB-4CHDS3-E3-IQE-BNC4“Channelized DS3/E3Enhanced IQ (IQE) PIC(T4000 Router)” on page 82
12.2R1Optical: LCPB-4CHOC12-STM4-IQE-SFP4“Channelized OC12/STM4Enhanced IQ (IQE) PICs withSFP (T4000 Router)” onpage 92
13.2Optical: LCPC-4CHOC12-STM4-IQE-SFP4
12.2R1Optical: LCPB-1CHOC48-STM16-IQE-SFP1“Channelized OC48/STM16Enhanced IQ (IQE) PIC withSFP (T4000 Router)” onpage 99
Gigabit Ethernet PICs
Table 5 on page 4 lists the Gigabit Ethernet PICs supported by the T4000 router.
Table 5: Gigabit Ethernet PICs Supported in the T4000 Router
First Junos OSReleaseSupportConnectorsModel NumberPortsPIC Family and Type
12.2R2Optical: LCPB-2GE-SFP2“Gigabit Ethernet PICs withSFP (T4000 Router)” onpage 113 12.2R2Optical: LCPB-4GE-SFP4
12.1R2Optical: LCPC-10GE-SFP10
12.2R2Optical: LCPB-2GE-SFP-QPP2“Gigabit Ethernet IQ PIC withSFP (T4000 Router)” onpage 116
12.1R2Optical: LCPC-8GE-TYPE3-SFP-IQ28“Gigabit Ethernet IQ2 PICswith SFP (T4000Router)” onpage 119 12.2R2Optical: LCPB-8GE-TYPE2-SFP-IQ28
12.1R2Optical: LCPC-8GE-TYPE3-SFP-IQ2E8“Gigabit Ethernet EnhancedIQ2 (IQ2E) PIC with SFP(T4000 Router)” on page 122
10-Gigabit Ethernet PICs
Table 6 on page 5 lists the 10-Gigabit Ethernet PICs supported by the T4000 router.
Copyright © 2017, Juniper Networks, Inc.4
T4000 Core Router Interface Module Reference
Table 6: 10-Gigabit Ethernet PICs Supported in the T4000 Router
First Junos OSReleaseSupportConnectorsModel NumberPortsPIC Family and Type
12.2R2Optical: SCPC-1XGE-XENPAK1“10-Gigabit Ethernet PIC withXENPAK (T4000 Router)” onpage 127
12.1R2Optical: LCPC-1XGE-TYPE3-XFP-IQ21“10-Gigabit Ethernet IQ2 PICwith XFP (T4000Router)” onpage 130
12.1R2Optical: LCPC-1XGE-TYPE3-XFP-IQ2E1“10-Gigabit Ethernet IQ2E PICwith XFP (T4000Router)” onpage 133
12.1Optical: LCPF-12XGE-SFPP12“10-Gigabit EthernetLAN/WAN PIC with SFP+(T4000Router)” on page 136
12.1R2Optical: LCPD-5-10XGE-SFPP10“10-Gigabit EthernetLAN/WAN PIC withOversubscription and SFP+(T4000Router)” on page 140
12.2Optical: LCPF-24XGE-SFPP24
12.1R2Optical: LCPD-4XGE-XFP4“10-Gigabit EthernetLAN/WAN PIC with XFP(T4000 Router)” on page 147
40-Gigabit Ethernet PICs
Table 7 on page 5 lists the 40-Gigabit Ethernet PICs supported by the T4000 router.
Table 7: 40-Gigabit Ethernet PICs Supported in the T4000 Router
First Junos OSReleaseSupportConnectorsModel NumberPortsPIC Family and Type
13.2Optical: SCPD-1XLE-CFP4“40-Gigabit Ethernet PICwithCFP (T4000 Router)” onpage 151
100-Gigabit Ethernet PICs
Table 8 on page 6 lists the 100-Gigabit Ethernet PICs supported by the T4000 router.
5Copyright © 2017, Juniper Networks, Inc.
Chapter 1: T4000 Interface Modules Support
Table 8: 100-Gigabit Ethernet PICs Supported in the T4000 Router
First Junos OSReleaseSupportConnectorsModel NumberPortsPIC Family and Type
12.1Optical: SC, LC, or24-fiber MPO
PF-1CGE-CFP1“100-GigabitEthernetPICwithCFP (T4000 Router)” onpage 155 depending on the
transceiver. See thePIC description formore information.
12.1R2Optical: SC, LC, or24-fiber MPO
PD-1CE-CFP-FPC4 (PIC and FPC)
NOTE: This PIC is available onlypackaged in an assembly with theT1600-FPC4-ES FPC.
1
depending on thetransceiver. See thePIC description formore information.
Services PICs
Table 9 on page 6 lists the services PICs supported by the T4000 router.
Table 9: Services PICs Supported in the T4000 Router
First Junos OSReleaseSupportConnectorsModel NumberPortsPIC Family and Type
12.2NonePB-MS-400-20“MultiServices PICs (T4000Router)” on page 163
12.1R2NonePB-MS-500-30
12.1R2NonePC-TUNNEL0“TunnelServicesPICs (T4000Router)” on page 167
12.2R2NonePB-TUNNEL0
SONET/SDH PICs
Table 10 on page 6 lists the SONET/SDH PICs supported by the T4000 router.
Table 10: SONET/SDH PICs Supported in the T4000 Router
First Junos OSReleaseSupportConnectorsModel NumberPortsPIC Family and Type
12.2R2Optical: LCPB-4OC3-1OC12-SON2-SFP4“SONET/SDHOC3/STM1(Multi-Rate) PICs with SFP(T4000Router)” on page 169
12.2R2Optical: LCPB-4OC3-4OC12-SON-SFP4“SONET/SDHOC12/STM4(Multi-Rate) PICs with SFP(T4000 Router)” on page 174
Copyright © 2017, Juniper Networks, Inc.6
T4000 Core Router Interface Module Reference
Table 10: SONET/SDH PICs Supported in the T4000 Router (continued)
First Junos OSReleaseSupportConnectorsModel NumberPortsPIC Family and Type
12.1R2Optical: LCPC-4OC48-SON-SFP4“SONET/SDHOC48c/STM16PICwithSFP(T4000Router)”on page 178
12.2R2Optical: SCPB-1OC48-SON-SMSR1
13.2Opticl: LCPC-4OC48-STM16-IQE-SFP4“SONET/SDHOC48/STM16Enhanced IQ (IQE) PIC withSFP (T4000 Router)” onpage 182
12.2R2Optical: LCPB-1OC48-SON-B-SFP1“SONET/SDHOC48/STM16(Multi-Rate) PIC with SFP(T4000Router)” on page 186
12.1R2Optical: LCPC-1OC192-SON-XFP1“SONET/SDHOC192/STM64PICs with XFP (T4000Router)” on page 190 12.1Optical: LCPD-4OC192-SON-XFP4
12.1Optical: SCPD-1OC768-SON-SR1“SONET/SDHOC768c/STM256PIC(T4000Router)” on page 195
RelatedDocumentation
T4000 PIC Description•
• T4000 End-of-Life PICs Supported on page 7
• T4000 PIC/FPC Compatibility on page 8
T4000 End-of-Life PICs Supported
Table 11 on page 8 lists the end-of-life PICs supported by the T4000 router. The PICs
are listed alphabetically by PIC family.
NOTE: End-of-life (EOL) indicates that the product has been removed fromthe price list and is no longer available for purchase. End-of-support (EOS)indicates that no new support contracts are available on these products andthe last contract will expire on the EOS date associated with each product.
7Copyright © 2017, Juniper Networks, Inc.
Chapter 1: T4000 Interface Modules Support
Table 11: End-of-Life PICs Supported in the T4000 Router
First Junos OSReleaseSupportConnectorsModel NumberPortsPIC Family and Type
12.1R2Optical: SCPC-1XGE-DWDM-OTN1“10-Gigabit Ethernet DWDMOTN EOL PIC(T4000 Router)” on page 199
12.2R2Optical: SCPB-4OC12-SON-MM
PB-4OC12-SON-SMIR
4“SONET/SDHOC12c/STM4 EOL PIC(T4000 Router)” on page 201
12.1R2Optical: SCPC-4OC48-SON-SMSR4“SONET/SDHOC48c/STM16 EOL PICs(T4000 Router)” on page 205
12.2R2Optical: SCPB-1OC48-SON-SMSR1
12.2R2Optical: LCPB-1OC48-SON-SFP1“SONET/SDHOC48c/STM16EOLPICwithSFP (T4000 Router)” on page 209
12.1R2Optical: SCPC-1OC192-SON-SR21“SONET/SDHOC192/STM64 EOL PIC(T4000 Router)” on page 212
RelatedDocumentation
T4000 PIC Description•
• T4000 PICs Supported on page 3
• T4000 PIC/FPC Compatibility on page 8
T4000 PIC/FPC Compatibility
The PIC/FPC compatibility matrixes list the current PICs for the T4000 router. For
example, JunosOSRelease 12.1 is the first release inwhich the T1600-FPC4-ES supports
the OC192/STM64, 4-port PIC in the T4000 router.
• PIC/FPC Compatibility (Type 1) on page 8
• PIC/FPC Compatibility (Type 2) on page 10
• PIC/FPC Compatibility (Type 3) on page 11
• PIC/FPC Compatibility (Type 4) on page 14
• PIC/FPC Compatibility (Type 5) on page 14
PIC/FPC Compatibility (Type 1)
Table 12 on page 9 provides a PIC/FPC compatibility matrix for the current Type 2 PICs
for the T4000 router and Type 2 FPCs.
Copyright © 2017, Juniper Networks, Inc.8
T4000 Core Router Interface Module Reference
Table 12: T4000 PIC/FPC Compatibility Type 1
T640-FPC1-ESPICModel NumberType 1 PIC
Channelized IQ PICs
12.1R2PB-4CHDS3-QPP“Channelized DS3 IQ PIC (T4000Router)” on page 73
12.1.R2PB-1CHOC3-SMIR-QPP“Channelized OC3 IQ PIC (T4000Router)” on page 78
12.1.R2PB-1CHSTM1-SMIR-QPP“ChannelizedSTM1 IQPIC (T4000Router)” on page 76
Channelized IQE PICs
12.1.R2PB-4CHDS3-E3-IQE-BNC“ChannelizedDS3/E3Enhanced IQ(IQE) PIC (T4000 Router)” onpage 82
12.1.R2PB-1OCHE1-T1-IQE-RJ48“Channelized E1/T1 Enhanced IQ(IQE) PIC (T4000 Router)” onpage 85
12.1.R2PB-2CHOC3-STM1-IQE-SFP“ChannelizedOC3/STM1EnhancedIQ (IQE) PIC with SFP (T4000Router)” on page 88
12.1.R2PB-1CHOC12-STM4-IQE-SFP“Channelized OC12/STM4Enhanced IQ (IQE) PICs with SFP(T4000 Router)” on page 92
DS3 and E3 PICs
12.1.R2PB-4DS3-E3-IQE-BNC“DS3/E3 Enhanced IQ (IQE) PIC(T4000 Router)” on page 107
Fast Ethernet and Gigabit Ethernet PICs
12.1.R2PB-4FE-TX“Fast Ethernet PIC (T4000Router)” on page 111
12.1.R2PB-1GE-SFPGigabit Ethernet PICs with SFP(T4000 Router)
Gigabit Ethernet IQ2 PICs
12.1.R2PB-4GE-TYPE1-SFP-IQ2“Gigabit Ethernet IQ2 PICs withSFP (T4000 Router)” on page 119
Gigabit Ethernet IQ2E PICs
12.1.R2PB-4GE-TYPE1-SFP-IQ2E“Gigabit Ethernet Enhanced IQ2(IQ2E) PIC with SFP (T4000Router)” on page 122
Services PICs
9Copyright © 2017, Juniper Networks, Inc.
Chapter 1: T4000 Interface Modules Support
Table 12: T4000 PIC/FPC Compatibility Type 1 (continued)
T640-FPC1-ESPICModel NumberType 1 PIC
12.1.R2PB-TUNNEL1“Tunnel Services PICs (T4000Router)” on page 167
SONET/SDH PICs
12.1.R2PB-4OC3-1OC12-SON-SFP“SONET/SDHOC3/STM1(Multi-Rate) PICs with SFP(T4000 Router)” on page 169
12.1.R2PB-1OC12-SON-SFP“SONET/SDHOC12/STM4(Multi-Rate) PICs with SFP(T4000 Router)” on page 174
PIC/FPC Compatibility (Type 2)
Table 13 on page 10 provides a PIC/FPC compatibility matrix for the current Type 2 PICs
for the T4000 router and Type 2 FPCs.
Table 13: T4000 PIC/FPC Compatibility Type 2
T640-FPC2-ESPICModel NumberType 2 PIC
ATMPICs
12.2.R1PB-2OC12-ATM2-SMIR“ATM2OC12/STM4IQPIC(T4000Router)” on page 67
Channelized IQ PICs
12.2R2PB-4CHOC12-STM4-IQE-SFP“Channelized OC12/STM4Enhanced IQ (IQE) PICs with SFP(T4000 Router)” on page 92
12.2R2PB-1CHOC48-STM16-IQE-SFP“Channelized OC48/STM16Enhanced IQ (IQE) PIC with SFP(T4000 Router)” on page 99
Gigabit Ethernet PICs
12.2R2PB-2GE-SFP“Gigabit Ethernet PICs with SFP(T4000 Router)” on page 113
12.2R2PB-4GE-SFP
Copyright © 2017, Juniper Networks, Inc.10
T4000 Core Router Interface Module Reference
Table 13: T4000 PIC/FPC Compatibility Type 2 (continued)
T640-FPC2-ESPICModel NumberType 2 PIC
12.2R2PB-2GE-SFP-QPP“Gigabit Ethernet IQ PIC with SFP(T4000 Router)” on page 116
12.2R2PB-8GE-TYPE2-SFP-IQ2“Gigabit Ethernet IQ2 PICs withSFP (T4000 Router)” on page 119
Services PICs
12.2PB-MS-400-2“MultiServices PICs (T4000Router)” on page 163
12.2R2PB-TUNNEL“Tunnel Services PICs (T4000Router)” on page 167
SONET/SDH PICs
12.2R2PB-4OC3-1OC12-SON2-SFP“SONET/SDHOC3/STM1(Multi-Rate) PICs with SFP(T4000 Router)” on page 169
12.2R2PB-4OC12-SON-MM
PB-4OC12-SON-SMIR
“SONET/SDHOC12c/STM4 EOLPIC (T4000 Router)” on page 201
12.2R2PB-4OC3-4OC12-SON-SFP“SONET/SDHOC12/STM4(Multi-Rate) PICs with SFP(T4000 Router)” on page 174
12.1R2PC-4OC48-SON-SMSR“SONET/SDHOC48c/STM16 EOLPICs(T4000Router)”onpage205
12.2R2PB-1OC48-SON-SMSR
12.2R2PB-1OC48-SON-SFP“SONET/SDHOC48c/STM16 EOLPIC with SFP (T4000 Router)” onpage 209
12.2R2PB-1OC48-SON-B-SFP“SONET/SDHOC48/STM16(Multi-Rate)PICwithSFP(T4000Router)” on page 186
PIC/FPC Compatibility (Type 3)
Table 14 on page 11 provides a PIC/FPC compatibility matrix for the current Type 3 PICs
for the T4000 router and Type 3 FPCs.
Table 14: T4000 PIC/FPC Compatibility Type 3
T640-FPC3-ESPICModel NumberType 3 PIC
Channelized IQE
11Copyright © 2017, Juniper Networks, Inc.
Chapter 1: T4000 Interface Modules Support
Table 14: T4000 PIC/FPC Compatibility Type 3 (continued)
T640-FPC3-ESPICModel NumberType 3 PIC
13.2PC-4CHOC12-STM4-IQE-SFP“Channelized OC12/STM4Enhanced IQ (IQE) PICs with SFP(T4000 Router)” on page 92
Gigabit Ethernet PICs
12.1R2PC-10GE-SFP“Gigabit Ethernet PICs with SFP(T4000 Router)” on page 113
12.1R2PC-8GE-TYPE3-SFP-IQ2“Gigabit Ethernet IQ2 PICs withSFP (T4000 Router)” on page 119
12.1R2PC-8GE-TYPE3-SFP-IQ2“Gigabit Ethernet Enhanced IQ2(IQ2E) PIC with SFP (T4000Router)” on page 122
Copyright © 2017, Juniper Networks, Inc.12
T4000 Core Router Interface Module Reference
Table 14: T4000 PIC/FPC Compatibility Type 3 (continued)
T640-FPC3-ESPICModel NumberType 3 PIC
10-Gigabit Ethernet PICs
12.2R2PC-1XGE-XENPAK“10-Gigabit Ethernet PIC withXENPAK (T4000 Router)” onpage 127
12.1R2PC-1XGE-DWDM-OTN“10-Gigabit Ethernet DWDMOTNEOL PIC (T4000 Router)” onpage 199
12.1R2PC-1XGE-TYPE3-XFP-IQ2“10-Gigabit Ethernet IQ2 PIC withXFP (T4000Router)” onpage 130
12.1R2PC-1XGE-TYPE3-XFP-IQ2E“10-Gigabit Ethernet IQ2EPICwithXFP (T4000Router)” on page 133
Services PICs
12.1R2PC-MS-500-3“MultiServices PICs (T4000Router)” on page 163
12.1R2PC-TUNNEL“Tunnel Services PICs (T4000Router)” on page 167
SONET/SDH PICs
12.1R2PC-4OC48-SON-SMSR“SONET/SDHOC48c/STM16 EOLPICs(T4000Router)”onpage205
12.1R2PC-4OC48-SON-SFP“SONET/SDHOC48c/STM16 PICwith SFP (T4000 Router)” onpage 178
13.2PC-4OC48-STM16-IQE-SFP“SONET/SDHOC48/STM16Enhanced IQ (IQE) PIC with SFP(T4000 Router)” on page 182
13.2PC-1OC192-SON-XFP“SONET/SDHOC192/STM64PICswith XFP (T4000 Router)” onpage 190
13Copyright © 2017, Juniper Networks, Inc.
Chapter 1: T4000 Interface Modules Support
PIC/FPC Compatibility (Type 4)
Table 15 on page 14 provides a PIC/FPC compatibility matrix for the current Type 4 PICs
for the T4000 router and Type 4 FPCs.
Table 15: T4000 PIC/FPC Compatibility Type 4
T1600-FPC4-EST640-FPC4-1P-ESPICModel NumberType 4 PIC
10-Gigabit Ethernet PICs
12.1
NOTE: To supportPD-5-10XGE-SFPP,the hardwareversion of theT1600-FPC4-ES(part number710-013037)REV13or later is required.
12.1R2PD-5-10XGE-SFPP“10-Gigabit Ethernet LAN/WANPIC with Oversubscription andSFP+(T4000Router)”onpage140
12.112.1R2PD-4XGE-XFP“10-Gigabit Ethernet LAN/WANPIC with XFP (T4000 Router)” onpage 147
40-Gigabit Ethernet PICs
13.2—PD-1XLE-CFP“40-Gigabit EthernetPICwithCFP(T4000 Router)” on page 151
100-Gigabit Ethernet PICs
12.1R2—PD-1CE-CFP-FPC4 (PIC and FPC)
NOTE: This PIC is available onlypackaged in an assembly with theT1600-FPC4-ES FPC.
“100-GigabitEthernetPICwithCFP(T4000 Router)” on page 155
SONET/SDH PICs
12.112.1R2PD-4OC192-SON-XFP“SONET/SDHOC192/STM64PICswith XFP (T4000 Router)” onpage 190
12.112.1R2PD-1OC768-SON-SR“SONET/SDHOC768c/STM256PIC (T4000 Router)” on page 195
PIC/FPC Compatibility (Type 5)
Table 16 on page 15 provides a PIC/FPC compatibility matrix for the current Type 5 PICs
for the T4000 router and Type 5 FPCs.
Copyright © 2017, Juniper Networks, Inc.14
T4000 Core Router Interface Module Reference
Table 16: T4000 PIC/FPC Compatibility Type 5
T4000-FPC5-LSRT4000-FPC5-3DPICModel NumberType 5 PIC
10-Gigabit Ethernet PICs
12.3R212.1PF-12XGE-SFPP“10-Gigabit Ethernet LAN/WANPIC with SFP+ (T4000 Router)”on page 136
12.3R212.2PF-24XGE-SFPP“10-Gigabit Ethernet LAN/WANPIC with Oversubscription andSFP+(T4000Router)”onpage140
100-Gigabit Ethernet PICs
12.3R212.1PF-1CGE-CFP“100-GigabitEthernetPICwithCFP(T4000 Router)” on page 155
RelatedDocumentation
• T4000 PIC Description
• T4000 PICs Supported on page 3
• T4000 FPCs Supported
15Copyright © 2017, Juniper Networks, Inc.
Chapter 1: T4000 Interface Modules Support
Copyright © 2017, Juniper Networks, Inc.16
T4000 Core Router Interface Module Reference
CHAPTER 2
Network Interface Specifications
• Supported Network Interface Standards by Transceiver for ACX Series, M Series, MX
Series, and T Series Routers on page 17
• Fast Ethernet and Gigabit Ethernet Bidirectional SFP Optical Interface
Specifications on page 27
• Gigabit Ethernet 1000BASE Optical Interface Specifications on page 30
• Gigabit Ethernet 1000BASE-T Copper Interface Specifications on page 34
• 10-Gigabit Ethernet 10GBASE Optical Interface Specifications on page 34
• 10-Gigabit Ethernet DWDMOTNOptical Interface Specifications on page 39
• 10-Gigabit Ethernet DWDM Transceiver Wavelengths on page 44
• 40-Gigabit Ethernet 40GBASE-R Optical Interface Specifications on page 46
• 100-Gigabit Ethernet 100GBASE-R Optical Interface Specifications on page 49
• SONET/SDHOC3/STM1 Optical Interface Specifications on page 53
• SONET/SDHOC12/STM4 Optical Interface Specifications on page 55
• SONET/SDHOC48/STM16 Optical Interface Specifications on page 57
• SONET/SDHOC192/STM64 Optical Interface Specifications on page 60
• SONET/SDHOC768/STM256 Optical Interface Specifications on page 63
Supported Network Interface Standards by Transceiver for ACX Series, M Series, MXSeries, and T Series Routers
Table 17 on page 18 and Table 18 on page 25 list the transceivers supported by ACX, M,
MX, and T Series devices.
NOTE: Not all transceivers are supported on all devices. To determinewhichtransceivers are supported in a particular device, see the “Cables andConnectors” section for each PIC, MIC, or line card in the Interface ModuleReference for your device, or see the Hardware Compatibility Tool.
TIP: You can use the Hardware Compatibility Tool to find information about
the pluggable transceivers supported on your Juniper Networks device.
17Copyright © 2017, Juniper Networks, Inc.
• Table 17 on page 18 lists the supported Ethernet standards for each transceiver.
• Table 18 on page 25 lists the supported SONET standards for each transceiver.
Some transceivers support monitoring by using the operational mode CLI command
show interfaces diagnostics optics. To determine which transceivers support monitoring,
refer to the “Monitoring Available” column in Table 17 on page 18 andTable 18 on page 25.
For adescriptionof themonitoring fieldsdisplayedby the transceiver, see show interfaces
diagnostics optics (Gigabit Ethernet, 10-Gigabit Ethernet, 40-Gigabit Ethernet, 100-Gigabit
Ethernet, and Virtual Chassis Port) or show interfaces diagnostics optics (SONET).
CAUTION: If you face a problem running a Juniper Networks device that usesa third-partyopticor cable, the JuniperNetworksTechnicalAssistanceCenter(JTAC) can help you diagnose the source of the problem. Your JTAC engineermight recommendthatyoucheckthethird-partyopticorcableandpotentiallyreplace it with an equivalent Juniper Networks optic or cable that is qualifiedfor the device.
NOTE: For XFP transceivers that can support either the 10-Gigabit Ethernetor SONETOC192/STM64 specifications, check the standard supported forthe device into which the transceiver is installed. For example, theXFP-10G-E-OC192-IR2 transceiver installed in a 10-Gigabit Ethernet PICsupports the 10GBASE-E standard. However, the XFP-10G-E-OC192-IR2transceiver installed in a SONETOC192/STM64 PIC supports the SONETOC192/STM64 IR2 standard.
Table 17 on page 18 is organized by transmission speed and then alphabetically bymodel
number.
Table 17: Supported Ethernet Standards
SpecificationsStandardMonitoringAvailableConnector
TransceiverTypeModel Number
Ethernet 10BASE, Fast Ethernet 100BASE, and Gigabit Ethernet 1000BASE Specifications
• Fast Ethernet100BASE-FX OpticalInterface Specifications
100BASE-FXNoLCSFPSFP-1FE-FX
• Ethernet 10BASE-TCopper InterfaceSpecifications
• Fast Ethernet100BASE-T CopperInterface Specifications
• Gigabit Ethernet1000BASE-T CopperInterface Specificationson page 34
10/100/1000BASE-T
NoRJ-45SFPSFP-1GE-FE-E-T
Copyright © 2017, Juniper Networks, Inc.18
T4000 Core Router Interface Module Reference
Table 17: Supported Ethernet Standards (continued)
SpecificationsStandardMonitoringAvailableConnector
TransceiverTypeModel Number
• Gigabit Ethernet1000BASE OpticalInterface Specificationson page 30
1000BASE-LHYesLCSFPSFP-1GE-LH
• Gigabit Ethernet1000BASE OpticalInterface Specificationson page 30
1000BASE-LX
1000BASE-LX10
YesLCSFPSFP-1GE-LX
• Gigabit Ethernet1000BASE OpticalInterface Specificationson page 30
1000BASE-SXYesLCSFPSFP-1GE-SX
• Gigabit Ethernet1000BASE-T CopperInterface Specificationson page 34
1000BASE-TNoRJ-45SFPSFP-1GE-T
• Fast Ethernet andGigabit EthernetBidirectional SFPOptical InterfaceSpecifications onpage 27
100BASE-BXNoLCSFPSFP-FE20KT13R15
• Fast Ethernet andGigabit EthernetBidirectional SFPOptical InterfaceSpecifications onpage 27
100BASE-BXNoLCSFPSFP-FE20KT15R13
• Fast Ethernet andGigabit EthernetBidirectional SFPOptical InterfaceSpecifications onpage 27
1000BASE-BXYesLCSFPSFP-GE10KT13R14
• Fast Ethernet andGigabit EthernetBidirectional SFPOptical InterfaceSpecifications onpage 27
1000BASE-BXYesLCSFPSFP-GE10KT13R15
• Fast Ethernet andGigabit EthernetBidirectional SFPOptical InterfaceSpecifications onpage 27
1000BASE-BXYesLCSFPSFP-GE10KT14R13
19Copyright © 2017, Juniper Networks, Inc.
Chapter 2: Network Interface Specifications
Table 17: Supported Ethernet Standards (continued)
SpecificationsStandardMonitoringAvailableConnector
TransceiverTypeModel Number
• Fast Ethernet andGigabit EthernetBidirectional SFPOptical InterfaceSpecifications onpage 27
1000BASE-BXYesLCSFPSFP-GE10KT15R13
• Gigabit Ethernet1000BASE OpticalInterface Specificationson page 30
1000BASE-EXYesLCSFPSFP-GE40KM
• Fast Ethernet andGigabit EthernetBidirectional SFPOptical InterfaceSpecifications onpage 27
1000BASE-BXYesLCSFPSFP-GE40KT13R15
• Fast Ethernet andGigabit EthernetBidirectional SFPOptical InterfaceSpecifications onpage 27
1000BASE-BXYesLCSFPSFP-GE40KT15R13
• Gigabit Ethernet SFPCWDMOptical InterfaceSpecifications
NAYesLCSFPSFP-GE80KCW1470-ET
• Gigabit Ethernet SFPCWDMOptical InterfaceSpecifications
NAYesLCSFPSFP-GE80KCW1490-ET
• Gigabit Ethernet SFPCWDMOptical InterfaceSpecifications
NAYesLCSFPSFP-GE80KCW1510-ET
• Gigabit Ethernet SFPCWDMOptical InterfaceSpecifications
NAYesLCSFPSFP-GE80KCW1530-ET
• Gigabit Ethernet SFPCWDMOptical InterfaceSpecifications
NAYesLCSFPSFP-GE80KCW1550-ET
• Gigabit Ethernet SFPCWDMOptical InterfaceSpecifications
NAYesLCSFPSFP-GE80KCW1570-ET
• Gigabit Ethernet SFPCWDMOptical InterfaceSpecifications
NAYesLCSFPSFP-GE80KCW1590-ET
Copyright © 2017, Juniper Networks, Inc.20
T4000 Core Router Interface Module Reference
Table 17: Supported Ethernet Standards (continued)
SpecificationsStandardMonitoringAvailableConnector
TransceiverTypeModel Number
• Gigabit Ethernet SFPCWDMOptical InterfaceSpecifications
NAYesLCSFPSFP-GE80KCW1610-ET
10-Gigabit Ethernet 10GBASE Specifications
• 10-Gigabit EthernetDWDMOptical InterfaceSpecifications
• 10-Gigabit Ethernet10GBASE OpticalInterface Specificationson page 34
10-Gigabit Ethernetdensewavelength-divisionmultiplexing(DWDM)
YesSCFixedPC-1XGE-DWDM-CBAND
• 10-Gigabit EthernetDWDMOTNOpticalInterface Specificationson page 39
• 10-Gigabit Ethernet10GBASE OpticalInterface Specificationson page 34
10-Gigabit Ethernetdensewavelength-divisionmultiplexing(DWDM) OTN
YesSCFixedPC-1XGE-DWDM-OTN
• 10-Gigabit Ethernet10GBASE OpticalInterface Specificationson page 34
10GBASE-ZYesLCSFP+SFPP-10G-CT50-ZR
• 10-Gigabit Ethernet10GBASE OpticalInterface Specificationson page 34
10BASE-ZYesLCSFP+SFPP-10G-DT-ZRC2
• 10-Gigabit Ethernet10GBASE OpticalInterface Specificationson page 34
10GBASE-ERYesLCSFP+SFPP-10G-ER-OTN
• 10-Gigabit Ethernet10GBASE OpticalInterface Specificationson page 34
10GBASE-LRYesLCSFP+SFPP-10G-LR-OTN
• 10-Gigabit Ethernet10GBASE OpticalInterface Specificationson page 34
10GBASE-ZYesLCSFP+SFPP-10G-ZR-OTN-XT
• 10-Gigabit Ethernet10GBASE OpticalInterface Specificationson page 34
10GBASE-ERYesLCSFP+SFPP-10GE-ER
21Copyright © 2017, Juniper Networks, Inc.
Chapter 2: Network Interface Specifications
Table 17: Supported Ethernet Standards (continued)
SpecificationsStandardMonitoringAvailableConnector
TransceiverTypeModel Number
• 10-Gigabit Ethernet10GBASE OpticalInterface Specificationson page 34
10GBASE-LRYesLCSFP+SFPP-10GE-LR
• 10-Gigabit Ethernet10GBASE OpticalInterface Specificationson page 34
10GBASE-LRMYesLCSFP+SFPP-10GE-LRM
• 10-Gigabit Ethernet10GBASE OpticalInterface Specificationson page 34
10GBASE-SRYesLCSFP+SFPP-10GE-SR
• 10-Gigabit Ethernet10GBASE OpticalInterface Specificationson page 34
10GBASE-ZYesLCSFP+SFPP-10GE-ZR
• 10-Gigabit Ethernet10GBASE OpticalInterface Specificationson page 34
10GBASE-ERYesSCXENPAKXENPAK-1XGE-ER
• 10-Gigabit Ethernet10GBASE OpticalInterface Specificationson page 34
10GBASE-LRYesSCXENPAKXENPAK-1XGE-LR
• 10-Gigabit Ethernet10GBASE OpticalInterface Specificationson page 34
10GBASE-SRYesSCXENPAKXENPAK-1XGE-SR
• 10-Gigabit Ethernet10GBASE OpticalInterface Specificationson page 34
10GBASE-ZYesSCXENPAKXENPAK-1XGE-ZR
EOL (seePSN-2010-02-649)
• 10-Gigabit Ethernet10GBASE OpticalInterface Specificationson page 34
10GBASE-Z
10-Gigabit Ethernetdensewavelength-divisionmultiplexing(DWDM)
YesLCXFPXFP-10G-CBAND-T50-ZR
• 10-Gigabit Ethernet10GBASE OpticalInterface Specificationson page 34
10GBASE-EYesLCXFPXFP-10G-E-OC192-IR2
Copyright © 2017, Juniper Networks, Inc.22
T4000 Core Router Interface Module Reference
Table 17: Supported Ethernet Standards (continued)
SpecificationsStandardMonitoringAvailableConnector
TransceiverTypeModel Number
• 10-Gigabit Ethernet10GBASE OpticalInterface Specificationson page 34
10GBASE-LYesLCXFPXFP-10G-L-OC192-SR1
• 10-Gigabit Ethernet10GBASE OpticalInterface Specificationson page 34
10GBASE-SYesLCXFPXFP-10G-S
• 10-Gigabit Ethernet10GBASE OpticalInterface Specificationson page 34
10GBASE-ZYesLCXFPXFP-10G-Z-OC192-LR2
40-Gigabit Ethernet 40GBASE Specifications
• 40-Gigabit Ethernet40GBASE-R OpticalInterface Specificationson page 46
40GBASE-LR4YesSCCFPCFP-40GBASE-LR4
• 40-Gigabit Ethernet40GBASE-R OpticalInterface Specificationson page 46
40GBASE-LX4YesLCQSFP+QSFPP-40G-LX4
• 40-Gigabit Ethernet40GBASE-R OpticalInterface Specificationson page 46
40GBASE-LX4YesLCQSFP+QSFPP-40GE-LX4
• 40-Gigabit Ethernet40GBASE-R OpticalInterface Specificationson page 46
40GBASE-ER4YesLCQSFP+QSFPP-40GBASE-ER4
• 40-Gigabit Ethernet40GBASE-R OpticalInterface Specificationson page 46
40GBASE-LR4YesLCQSFP+QSFPP-40GBASE-LR4
• 40-Gigabit Ethernet40GBASE-R OpticalInterface Specificationson page 46
40GBASE-SR4Yes12-fiberMPO
QSFP+QSFPP-40GBASE-SR4
100-Gigabit Ethernet 100GBASE-R Specifications
• 100-Gigabit Ethernet100GBASE-R OpticalInterface Specificationson page 49
100GBASE-ER4YesLCCFPCFP-100GBASE-ER4
23Copyright © 2017, Juniper Networks, Inc.
Chapter 2: Network Interface Specifications
Table 17: Supported Ethernet Standards (continued)
SpecificationsStandardMonitoringAvailableConnector
TransceiverTypeModel Number
• 100-Gigabit Ethernet100GBASE-R OpticalInterface Specificationson page 49
100GBASE-ER4YesLCCFPCFP-GEN2-CGE-ER4
• 100-Gigabit Ethernet100GBASE-R OpticalInterface Specificationson page 49
100GBASE-LR4YesSCCFPCFP-100GBASE-LR4
• 100-Gigabit Ethernet100GBASE-R OpticalInterface Specificationson page 49
100GBASE-LR4YesLCCFPCFP-GEN2-100GBASE-LR4
• 100-Gigabit Ethernet100GBASE-R OpticalInterface Specificationson page 49
100GBASE-SR10Yes
NOTE:Opticalpowermonitoringis notsupported.
24-fiberMPO
CFPCFP-100GBASE-SR10
• See the JuniperNetworks specificationin the “100-GigabitEthernet 100GBASE-ROptical InterfaceSpecifications” onpage 49.
NoneYesLCCFPCFP-100GBASE-ZR
• See the JuniperNetworks specificationin the “100-GigabitEthernet 100GBASE-ROptical InterfaceSpecifications” onpage 49.
100GBASE-LR4YesLCCFP2CFP2-100GBASE-LR4
• See the JuniperNetworks specificationin the “100-GigabitEthernet 100GBASE-ROptical InterfaceSpecifications” onpage 49.
100GBASE-ER4YesLCCFP2CFP2-100G-ER4-D
Copyright © 2017, Juniper Networks, Inc.24
T4000 Core Router Interface Module Reference
Table 17: Supported Ethernet Standards (continued)
SpecificationsStandardMonitoringAvailableConnector
TransceiverTypeModel Number
• See the JuniperNetworks specificationin the “100-GigabitEthernet 100GBASE-ROptical InterfaceSpecifications” onpage 49.
100GBASE-SR10Yes24-fiberMPO
CFP2CFP2-100G-SR10-D3
• 100-Gigabit Ethernet100GBASE-R OpticalInterface Specificationson page 49
100GBASE-SR10Yes24-fiberMPO
CXPCXP-100GBASE-SR10
• 100-Gigabit Ethernet100GBASE-R OpticalInterface Specificationson page 49
100G-SR4Yes12-fiberMPO
QSFP28QSFP28-100G-SR4
• 100-Gigabit Ethernet100GBASE-R OpticalInterface Specificationson page 49
100G-LR4YesLCQSFP28QSFP28-100G-LR4
• 100-GigabitDWDMOTNCFP2-ACO TransceiverWavelengths
100-Gigabit DWDMOTN
YesLC/UPCCFP2-ACOTCFP2-100G-C
Table 18onpage25 is organizedby transmission speedand thenalphabetically bymodel
number.
Table 18: Supported SONET Standards
SpecificationsStandardMonitoringAvailableConnector
TransceiverTypeModel Number
SONETOC3/STM1 Specifications
• SONET/SDHOC3/STM1Optical InterfaceSpecifications on page 53
SONET/SDHOC3/STM1Intermediate Reach
YesLCSFPSFP-OC3-IR
• SONET/SDHOC3/STM1Optical InterfaceSpecifications on page 53
SONET/SDHOC3/STM1LongReach
YesLCSFPSFP-OC3-LR
• SONET/SDHOC3/STM1Optical InterfaceSpecifications on page 53
SONET/SDHOC3/STM1 Multimode
YesLCSFPSFP-OC3-SR
SONETOC12/STM4 Specifications
25Copyright © 2017, Juniper Networks, Inc.
Chapter 2: Network Interface Specifications
Table 18: Supported SONET Standards (continued)
SpecificationsStandardMonitoringAvailableConnector
TransceiverTypeModel Number
• SONET/SDHOC12/STM4Optical InterfaceSpecifications on page 55
SONET/SDHOC12/STM4Intermediate Reach(IR-1)
YesLCSFPSFP-OC12-IR
• SONET/SDHOC12/STM4Optical InterfaceSpecifications on page 55
SONET/SDHOC12/STM4 LongReach (LR-1)
YesLCSFPSFP-OC12-LR
• SONET/SDHOC12/STM4Optical InterfaceSpecifications on page 55
SONET/SDHOC12/STM4 LongReach (LR-2)
YesLCSFPSFP-OC12-LR2
• SONET/SDHOC12/STM4Optical InterfaceSpecifications on page 55
SONET/SDHOC12/STM4 ShortReach (SR-1)
YesLCSFPSFP-OC12-SR
SONETOC48/STM16 Specifications
• SONET/SDHOC48/STM16 OpticalInterface Specificationson page 57
SONET/SDHOC48/STM16Intermediate Reach(IR-1)
NoLCSFPSFP-1OC48-IR
• SONET/SDHOC48/STM16 OpticalInterface Specificationson page 57
SONET/SDHOC48/STM16 LongReach (LR-2)
YesLCSFPSFP-1OC48-LR
• SONET/SDHOC48/STM16 OpticalInterface Specificationson page 57
SONET/SDHOC48/STM16 ShortReach (SR-1)
NoLCSFPSFP-1OC48-SR
SONETOC192/STM64 Specifications
• SONET/SDHOC192/STM64 OpticalInterface Specificationson page 60
SONET/SDHOC192/STM64Intermediate Reach(IR-2)
YesLCXFPXFP-10G-E-OC192-IR2
• SONET/SDHOC192/STM64 OpticalInterface Specificationson page 60
SONET/SDHOC192/STM64 ShortReach (SR-1)
YesLCXFPXFP-10G-L-OC192-SR1
• SONET/SDHOC192/STM64 OpticalInterface Specificationson page 60
SONET/SDHOC192/STM64 LongReach (LR-2)
YesLCXFPXFP-10G-Z-OC192-LR2
SONETOC768/STM256 Specifications
Copyright © 2017, Juniper Networks, Inc.26
T4000 Core Router Interface Module Reference
Table 18: Supported SONET Standards (continued)
SpecificationsStandardMonitoringAvailableConnector
TransceiverTypeModel Number
• SONET/SDHOC768/STM256 OpticalInterface Specificationson page 63
SONET/SDHOC768/STM256ShortReach (SR)
YesSCFixedPD-1OC768-SON-SR
Fast Ethernet and Gigabit Ethernet Bidirectional SFPOptical Interface Specifications
The bidirectional SFP standards are supported on M Series, MX Series, and T Series
routers.
Todeterminewhich transceivers support eachbidirectionalSFPstandard, see “Supported
Network Interface Standards by Transceiver for ACX Series, M Series, MX Series, and T
Series Routers” on page 17. The “Cables and connectors” section in the description for
each MIC or PIC lists which standards and transceivers are supported for that device.
The standards are organized by distance supported.
• FastEthernet 100BASE-BXBidirectionalSFPOptical InterfaceSpecificationsonpage27
• GigabitEthernet 1000BASE-BXBidirectionalSFP(U13/14andD14/13)Optical Interface
Specifications on page 28
• GigabitEthernet 1000BASE-BXBidirectionalSFP(U13/15andD15/13)Optical Interface
Specifications on page 29
• Gigabit Ethernet 1000BASE-BX Bidirectional SFP (40 U 13/15 and D 15/13) Optical
Interface Specifications on page 30
Fast Ethernet 100BASE-BX Bidirectional SFPOptical Interface Specifications
Table 19 on page 27 shows the optical specifications for 100BASE-BXbidirectional SFPs.
100BASE-BX bidirectional interfaces are supported in Junos OS Release 9.6 and later
andmust be used in pairs.
Table 19: Fast Ethernet 100BASE-BX Bidirectional SFPOptical Interface Specifications
100BASE-BX-D100BASE-BX-UParameter
100BASE-BX-U100BASE-BX-DPairs with
SFP-FE20KT15R13SFP-FE20KT13R15Transceiver model number
100Mbps100MbpsRate
Single-modeSingle-modeOptical interface
SFPSFPTransceiver type
27Copyright © 2017, Juniper Networks, Inc.
Chapter 2: Network Interface Specifications
Table 19: Fast Ethernet 100BASE-BX Bidirectional SFPOptical InterfaceSpecifications (continued)
100BASE-BX-D100BASE-BX-UParameter
100BASE-BXIEEE 802.3-2005
100BASE-BXIEEE 802.3-2005
Standard
9/125 SMF cable:12.4 miles (20 km)
9/125 SMF cable:12.4 miles (20 km)
Maximum distance
1480 through 1580 nm1260 through 1360 nmTransmitter wavelength
–14 through –8 dBm–14 through –8 dBmAverage launch power
–45 through –8 dBm–45 through –8 dBmAverage receive power
–8 dBm–8 dBmReceiver saturation
–45 dBm–45 dBmReceiver sensitivity
Gigabit Ethernet 1000BASE-BX Bidirectional SFP (U 13/14 and D 14/13) Optical InterfaceSpecifications
Table 20 on page 28 shows the optical specifications for 1000BASE-BX bidirectional
SFPs. 1000BASE-BX bidirectional interfaces are supported in Junos OS Release 9.0 and
later andmust be used in pairs.
Table 20: Gigabit Ethernet 1000BASE-BX Bidirectional SFP (U 13/14 and D 14/13) OpticalInterface Specifications
1000BASE-BX10-D 14/131000BASE-BX10-U 13/14Parameter
1000BASE-BX10-U 13/141000BASE-BX10-D 14/13Pairs with
SFP-GE10KT14R13SFP-GE10KT13R14Transceiver model number
1000Mbps1000MbpsRate
Single-modeSingle-modeOptical interface
SFPSFPTransceiver type
IEEE 802.3-2005IEEE 802.3-2005Standard
9/125 SMF cable:6.2 miles (10 km)
9/125 SMF cable:6.2 miles (10 km)
Maximum distance
1480 through 1500 nm1260 through 1360 nmTransmitter wavelength
–9 through –3 dBm–9 through –3 dBmAverage launch power
Copyright © 2017, Juniper Networks, Inc.28
T4000 Core Router Interface Module Reference
Table 20: Gigabit Ethernet 1000BASE-BX Bidirectional SFP (U 13/14 and D 14/13) OpticalInterface Specifications (continued)
1000BASE-BX10-D 14/131000BASE-BX10-U 13/14Parameter
–19.5 through –3 dBm–19.5 through –3 dBmAverage receive power
–3 dBm–3 dBmReceiver saturation
–19.5 dBm–19.5 dBmReceiver sensitivity
Gigabit Ethernet 1000BASE-BX Bidirectional SFP (U 13/15 and D 15/13) Optical InterfaceSpecifications
Table 22 on page 30 shows the optical specifications for 1000BASE-BX bidirectional
SFPs. 1000BASE-BX bidirectional interfaces are supported in Junos OS Release 9.0 and
later andmust be used in pairs.
Table 21: Gigabit Ethernet 1000BASE-BX Bidirectional SFP (U 13/15 and D 15/13) OpticalInterface Specifications
1000BASE-BX10-D 15/131000BASE-BX10-U 13/15Parameter
1000BASE-BX10-U 13/151000BASE-BX10-D 15/13Pairs with
SFP-GE10KT15R13SFP-GE10KT13R15Transceiver model number
1000Mbps1000MbpsRate
Single-modeSingle-modeOptical interface
SFPSFPTransceiver type
Multivendor agreementMultivendor agreementStandard
9/125 SMF cable:6.2 miles (10 km)
9/125 SMF cable:6.2 miles (10 km)
Maximum distance
1530 through 1570 nm1270 through 1360 nmTransmitter wavelength
–9 through –3 dBm–9 through –3 dBmAverage launch power
–20 through –3 dBm–20 through –3 dBmAverage receive power
–3 dBm–3 dBmReceiver saturation
–20 dBm–20 dBmReceiver sensitivity
29Copyright © 2017, Juniper Networks, Inc.
Chapter 2: Network Interface Specifications
Gigabit Ethernet 1000BASE-BX Bidirectional SFP (40 U 13/15 and D 15/13) Optical InterfaceSpecifications
Table 21 on page 29 shows the optical specifications for 1000BASE-BX bidirectional
SFPs. 1000BASE-BX bidirectional interfaces are supported in JUNOS 9.0 and later and
must be used in pairs.
Table 22: Gigabit Ethernet 1000BASE-BX Bidirectional SFP (40 U 13/15 and D 15/13) OpticalInterface Specifications
1000BASE-BX40-D 15/131000BASE-BX40-U 13/15Parameter
1000BASE-BX40-U 13/151000BASE-BX40-D 15/13Pairs with
SFP-GE40KT15R13SFP-GE40KT13R15Transceiver model number
1000Mbps1000MbpsRate
Single-modeSingle-modeOptical interface
SFPSFPTransceiver type
Multivendor agreementMultivendor agreementStandard
9/125 SMF cable:24.9 miles (40 km)
9/125 SMF cable:24.9 miles (40 km)
Maximum distance
1530 through 1570 nm1260 through 1360 nmTransmitter wavelength
–7 through 2 dBm–3 through 2 dBmAverage launch power
–23 through –3 dBm–23 through –3 dBmAverage receive power
–3 dBm–3 dBmReceiver saturation
–23 dBm–23 dBmReceiver sensitivity
RelatedDocumentation
Supported Network Interface Standards by Transceiver for ACX Series, M Series, MX
Series, and T Series Routers on page 17
•
Gigabit Ethernet 1000BASEOptical Interface Specifications
To determine which transceivers support each Gigabit Ethernet 1000BASE standard,
see “Supported Network Interface Standards by Transceiver for ACX Series, M Series,
MX Series, and T Series Routers” on page 17. The “Cables and connectors” section in the
description for eachDPC,MIC, orPIC listswhichstandardsand transceiversare supported.
Copyright © 2017, Juniper Networks, Inc.30
T4000 Core Router Interface Module Reference
The standards are organized by distance supported.
• Gigabit Ethernet 1000BASE-SX Optical Interface Specifications on page 31
• Gigabit Ethernet 1000BASE-LX Optical Interface Specifications on page 31
• Gigabit Ethernet 1000BASE-LX10 Optical Interface Specifications on page 32
• Gigabit Ethernet 1000BASE-EX Optical Interface Specifications on page 32
• Gigabit Ethernet 1000BASE-LH Optical Interface Specifications on page 33
Gigabit Ethernet 1000BASE-SXOptical Interface Specifications
Table 23 on page 31 shows the optical interface specifications for the 1000BASE-SX
standard.
Table23:GigabitEthernet 1000BASE-SXOptical InterfaceSpecifications
1000BASE-SXParameter
1000MbpsRate
MultimodeOptical interface
62.5/125 MMF cable:656 ft (200m)
50/125 MMF cable:1640 ft (500m)
Maximum distance
770 through 860 nmTransmitter wavelength
–9.5 through 0 dBmAverage launch power
–17 through 0 dBmAverage receive power
0 dBmReceiver saturation
–17 dBmReceiver sensitivity
Gigabit Ethernet 1000BASE-LXOptical Interface Specifications
Table 24 on page 31 shows the optical interface specifications for the 1000BASE-LX
standard.
Table24:GigabitEthernet 1000BASE-LXOptical InterfaceSpecifications
1000BASE-LXParameter
1000MbpsRate
Multimode and single-modeOptical interface
31Copyright © 2017, Juniper Networks, Inc.
Chapter 2: Network Interface Specifications
Table 24: Gigabit Ethernet 1000BASE-LXOptical InterfaceSpecifications (continued)
1000BASE-LXParameter
62.5/125and50/125MMFcable: 1804.5 ft (550m)
9/125 SMF cable: 6.2 miles (10 km)
Maximum distance
1270 through 1355 nmTransmitter wavelength
–11.5 through –3 dBmAverage launch power
–19 through –3 dBmAverage receive power
–3 dBmReceiver saturation
–19 dBmReceiver sensitivity
Gigabit Ethernet 1000BASE-LX10 Optical Interface Specifications
Table 25 on page 32 shows the optical interface specifications for the 1000BASE-LX10
standard.
Table 25: Gigabit Ethernet 1000BASE-LX10 Optical InterfaceSpecifications
1000BASE-LX10Parameter
1000MbpsRate
Single-modeOptical interface
9/125 SMF cable: 6.2 miles (10 km)Maximum distance
1270 through 1355 nmTransmitter wavelength
–11.5 through –3 dBmAverage launch power
–19 through –3 dBmAverage receive power
–3 dBmReceiver saturation
–19 dBmReceiver sensitivity
Gigabit Ethernet 1000BASE-EXOptical Interface Specifications
Table 25 on page 32 shows the optical interface specifications for the 1000BASE-EX
standard.
Copyright © 2017, Juniper Networks, Inc.32
T4000 Core Router Interface Module Reference
Table26:GigabitEthernet 1000BASE-EXOptical InterfaceSpecifications
1000BASE-EXParameter
1000MbpsRate
Single-modeOptical interface
9/125 SMF cable:24.85miles (40 km)
Maximum distance
1260 through 1360 nmTransmitter wavelength
–4.5 through 0 dBmAverage launch power
–22.5 through –3 dBmAverage receive power
–3 dBmReceiver saturation
–22.5 dBmReceiver sensitivity
Gigabit Ethernet 1000BASE-LHOptical Interface Specifications
Table27:GigabitEthernet 1000BASE-LHOptical InterfaceSpecifications
1000BASE-LHParameter
1000MbpsRate
Single-modeOptical interface
9/125 SMF cable:43.5 miles (70 km)
Maximum distance
1460 through 1580 nmTransmitter wavelength
–3 through +3 dBmAverage launch power
–20 through –3 dBmAverage receive power
–3 dBmReceiver saturation
–20 dBmReceiver sensitivity
RelatedDocumentation
Supported Network Interface Standards by Transceiver for ACX Series, M Series, MX
Series, and T Series Routers on page 17
•
33Copyright © 2017, Juniper Networks, Inc.
Chapter 2: Network Interface Specifications
Gigabit Ethernet 1000BASE-T Copper Interface Specifications
The 1000BASE-T copper standard is supported on M Series, MX Series, and T Series
routers.
To determine which transceivers support the 1000BASE-T copper standard, see
“Supported Network Interface Standards by Transceiver for ACX Series, M Series, MX
Series, and T Series Routers” on page 17. The “Cables and connectors” section in the
description for each MIC or PIC lists which standards and transceivers are supported for
that device.
Table 28 on page 34 shows the copper interface specifications for the 1000BASE-T
standard.
Table 28: 1000BASE-T Copper Interface Specifications
1000BASE-TParameter
1000Mbps autosensingRate
328 ft (100m)Distance
Four-pair, Category 5 shielded twisted-pairCable
RelatedDocumentation
Supported Network Interface Standards by Transceiver for ACX Series, M Series, MX
Series, and T Series Routers on page 17
•
10-Gigabit Ethernet 10GBASEOptical Interface Specifications
To determine which transceivers support each 10GBASE standard, see “Supported
Network Interface Standards by Transceiver for ACX Series, M Series, MX Series, and T
Series Routers” on page 17. The “Cables and Connectors” section in the description for
each MIC or PIC lists which standards and transceivers are supported for that device.
NOTE: SomeXFP transceivers can support either the 10-Gigabit Ethernet orSONET/SDHOC192/STM64 specifications. Check the standard supportedfor the device in which the transceiver is installed. For example, theXFP-10G-E-OC192-IR2 transceiver installed in a 10-Gigabit Ethernet PICsupports the 10GBASE-E standard. However, the XFP-10G-E-OC192-IR2transceiver installed in a SONET/SDHOC192/STM64 PIC supports theSONET/SDHOC192/STM64 IR2 standard.
The specifications are organized by distance supported.
• 10GBASE-LRM Specifications on page 35
• 10GBASE-S Specifications on page 35
Copyright © 2017, Juniper Networks, Inc.34
T4000 Core Router Interface Module Reference
• 10GBASE-L Specifications on page 36
• 10GBASE-E Specifications on page 37
• 10GBASE-Z Specifications on page 37
10GBASE-LRMSpecifications
Table 29 on page 35 shows the optical interface specifications for the 10GBASE-LRM
standard.
Table 29: 10GBASE-LRMOptical Interface Specifications
10GBASE-LRMParameter
Single-mode
Multimode
Optical interface
IEEE 802.3aq—2006Standard
Single-mode: 9/125 SMF cable: 300m (984 ft)
Multimode:
• 62.5 /125 MMF cable, 500MHz-km: 220m(722 ft)
• 50/125MMFcable, 500MHz-km:220m(722 ft)
• 50/125MMFcable,400MHz-km: 100m(328ft)
Maximum distance
1260 through 1355 nmTransmitter wavelength
–6.5 through +0.5 dBmAverage launch power
–8.4 through +0.5 dBmAverage receive power
+1.5 dBmOverload in OMA
–6.5 dBmStressed sensitivity in OMA
10GBASE-S Specifications
Table 30 on page 36 shows the optical interface specifications for the 10GBASE-SR and
10GBASE-SW standards.
NOTE: The XFP-10G-L-OC192-SR1 transceiver supports single-mode fiberand the 10GBASE-L optical interface specifications.
35Copyright © 2017, Juniper Networks, Inc.
Chapter 2: Network Interface Specifications
Table30: 10GBASE-S(10GBASE-SRand10GBASE-SW)Optical InterfaceSpecifications
10GBASE-SParameter
MultimodeOptical interface
IEEE 802.3ae—2002Standard
50/125 MMF cable, 400MHz-km: 66m (217 ft)
50/125 MMF cable. 500MHz-km: 82m (269 ft)
50/125MMFcable, 2000MHz-km:300m(948ft)
50/125MMFcable. 4700MHz-km:400m(1312 ft)
62.5/125 MMF cable, 200MHz-km: 33m (108 ft)
62.5/125 MMF cable, 160 MHz-km: 26m (85 ft)
Maximum distance
840 through 860 nmTransmitter wavelength
–7.3 through –1.0 dBmAverage launch power
–9.9 through –1.0 dBmAverage receive power
–1.0 dBmReceiver saturation
–11.1 dBmReceiver sensitivity (max) in OMA
10GBASE-L Specifications
Table 31 on page 36 shows the optical interface specifications for the 10GBASE-LR and
10GBASE-LW standards.
Table 31: 10GBASE-L (10GBASE-LR and 10GBASE-LW)Optical InterfaceSpecifications
10GBASE-LParameter
Single-modeOptical interface
IEEE 802.3ae—2002Standard
9/125 SMF cable: 10 km (6.2 miles)Maximum distance
1260 through 1355 nmTransmitter wavelength
–8.2 through 0.5 dBmAverage launch power
–14.4 through 0.5 dBmAverage receive power
0.5 dBmReceiver saturation
Copyright © 2017, Juniper Networks, Inc.36
T4000 Core Router Interface Module Reference
Table 31: 10GBASE-L (10GBASE-LR and 10GBASE-LW)Optical InterfaceSpecifications (continued)
10GBASE-LParameter
–12.6 dBmReceiver sensitivity (max) in OMA
10GBASE-E Specifications
Table 32 on page 37 shows the optical interface specifications for the 10GBASE-ER and
10GBASE-EW standards.
Table32: 10GBASE-E(10GBASE-ERand10GBASE-EW)Optical InterfaceSpecifications
10GBASE-EParameter
Single-modeOptical interface
IEEE 802.3ae—2002Standard
9/125 SMF cable: 40 km (24.8 miles); distancesgreater than 30 km (18.6 miles) are considered tobe engineered links.
NOTE: Any distance greater than 30 km requiresengineered links thatmust be field-tested to verifythe conformance of the 10.9 dB channel insertionloss specification. EANSI/TIA/EIA-526-7/MethodA1 describes the insertion loss measurement ofinstalled fiber-optic cables.
Maximum distance
1530 through 1565 nmTransmitter wavelength
–4.7 through 4.0 dBmAverage launch power
–15.8 through –1.0 dBmAverage receive power
–1.0 dBmReceiver saturation
–14.1 dBmReceiver sensitivity (max) in OMA
10GBASE-Z Specifications
Table 33 on page 37 shows the optical interface specifications for the 10GBASE-ZR and
10GBASE-ZW transceiver.
Table33: 10GBASE-Z(10GBASE-ZRand10GBASE-ZW)Optical InterfaceSpecifications
10GBASE-ZParameter
Single-modeOptical interface
37Copyright © 2017, Juniper Networks, Inc.
Chapter 2: Network Interface Specifications
Table33: 10GBASE-Z(10GBASE-ZRand10GBASE-ZW)Optical InterfaceSpecifications (continued)
10GBASE-ZParameter
MultivendorStandard
9/125 SMF cable: 80 km (49.6 miles)Maximum distance
1530 through 1565 nm
1528.77 through 1563.86 nm (tunable) forXFP-10G-CBAND-T50-ZR
1528.38 through 1568.77 nm (tunable) forSFPP-10G-CT50-ZR
1528.38 through 1568.77 nm (tunable) forSFPP-10G-DT-ZRC2
Transmitter wavelength
0 through 4.0 dBm for XENPAK-1XGE-ZR,XFP-10G-Z-OC192-LR2, andSFPP-10G-ZR-OTN-XT
–1.0 through +3.0 dBm forXFP-10G-CBAND-T50-ZR
0 through 4.0 dBm for SFPP-10GE-ZR
–1.0 through +3.0 dBm for SFPP-10G-CT50-ZRand SFPP-10G-DT-ZRC2
Average launch power
–25.0 through –7.0 dBm for XENPAK-1XGE-ZR
–23.0 through –7.0 dBm forXFP-10G-CBAND-T50-ZR
–24.0 through –7.0 dBm forXFP-10G-Z-OC192-LR2
–24.0 through –7.0 dBm for SFPP-10GE-ZR
–24.0 through –7.0 dBm for SFPP-10G-CT50-ZR
–24.0 through –7.0 dBm (9.95, 10.312, and10.709 Gbps) for SFPP-10G-DT-ZRC2
–24.0 through –7.0 dBm forSFPP-10G-ZR-OTN-XT
Average receive power
–7.0 dBm for XENPAK-1XGE-ZR,XFP-10G-CBAND-T50-ZR,XFP-10G-Z-OC192-LR2,SFPP-10G-CT50-ZR, SFPP-10G-DT-ZRC2, andSFPP-10G-ZR-OTN-XT
–8.0 dBm for SFPP-10GE-ZR
Receiver saturation
Copyright © 2017, Juniper Networks, Inc.38
T4000 Core Router Interface Module Reference
Table33: 10GBASE-Z(10GBASE-ZRand10GBASE-ZW)Optical InterfaceSpecifications (continued)
10GBASE-ZParameter
–25.0 dBm for XENPAK-1XGE-ZR
–23.0 dBM for XFP-10G-CBAND-T50-ZR
–24.0 dBm for XFP-10G-Z-OC192-LR2
–24.0 dBM for SFPP-10GE-ZR
–24.0 dBm for SFPP-10G-CT50-ZR
For SFPP-10G-DT-ZRC2:
• –24.0 dBm (9.95, 10.312, and 10.709 Gbps,BER < 1 x 10-12, no FEC)
• –25.0 dBm (11.049 and 11.095 Gbps,BER < 1 x 10-6, pre-FEC)
NOTE: When you use SFPP-10G-DT-ZRC2 inOTU1e (11.049 Gbps) or OTU2e (11.095 Gbps)applications, youmust enable forward errorcorrection (FEC) to achieve target receiversensitivity. To enable FECmode, use the feccommand at the [edit interfaces interface-nameotn-options] hierarchy level (see fec).
–24.0 dBm for SFPP-10G-ZR-OTN-XT
Receiver sensitivity
RelatedDocumentation
Supported Network Interface Standards by Transceiver for ACX Series, M Series, MX
Series, and T Series Routers on page 17
•
10-Gigabit Ethernet DWDMOTNOptical Interface Specifications
The 10-Gigabit Ethernet DWDMOTN PIC is supported on M120 routers and T Series
routers.
To determine which transceivers support each 10GBASE standard, see “Supported
Network Interface Standards by Transceiver for ACX Series, M Series, MX Series, and T
Series Routers” on page 17. The “Cables and connectors” section in the description for
each MIC or PIC lists which standards and transceivers are supported for that device.
• 10-Gigabit Ethernet DWDMOTNOptical Interface Specifications on page 39
• 10-Gigabit Ethernet DWDMOTN SupportedWavelengths on page 42
• PC-1XGE-DWDM-OTNOpticalSignal-to-NoiseRatio (OSNR)Performanceonpage44
10-Gigabit Ethernet DWDMOTNOptical Interface Specifications
Table34onpage40shows theoptical interface specifications for the 10-Gigabit Ethernet
DWDMOTN PIC transceiver.
39Copyright © 2017, Juniper Networks, Inc.
Chapter 2: Network Interface Specifications
Table 34: 10-Gigabit Ethernet DWDMOTNOptical Interface Specifications
• PICmodel number: PC-1XGE-DWDM-OTNModel number
• 10–Gigabit digital wrapper with over-clocked G.709 framing
• GenericReed-Solomon forward error correction (GFEC)andenhanced forward error correction(EFEC) to transport 10GBASE-R (10-Gigabit Ethernet LAN PHY)
• Reduced cost of deploying andmaintaining the network due to:
• Fewer optical-electrical-optical (OEO) conversions
• Fewer optical amplifiers and regenerators
• 89 tunable wavelengths (channels) supported per DWDM-OTNmodule
• Link fault switchover
Features
• Dense wavelength division multiplexing (DWDM)moduleTransceiver type
• ITU-T G.709—Interfaces for the Optical Transport Network (OTN). The PC-1XGE-DWDM-OTNPIC supports two OTN extendedmappings:
• Supplement 43, section 7.1, optical channel payload unit 2e (OPU2e). This mapping insertsthe original 10GE LAN PHY signal into a “digital wrapper” with overclocked G.709 framingthat results in a line rate of 11.1 Gbps instead of the standard 10.7 Gbps.
• Supplement 43, section 7.2, optical channel payload unit 1e (OPU1e). This mapping insertsthe original 10GE LAN PHY signal into a “digital wrapper” with overclocked G.709 framing,but without the use of fixed stuff bytes, that results in a line rate of 11.05 Gbps instead of thestandard 10.7 Gbps.
See ITU-TSeries GSupplement 43, ver 02/2008 formore information aboutOPU2e andOPU1eextendedmappings.
• ITU-T G.975—GFEC
• ITU-T G.975.1—Enhanced FEC
• ITU-T G.694.1—Spectral grids for WDM applications: DWDM frequency grid Series G:Transmission Systems and Media, Digital Systems and Networks Transmission mediacharacteristics-Characteristics of optical components and subsystems
• IEEE 802.3ae—2005
• RFC 3591—Definitions of Managed Objects for the Optical Interface Type
Standards
• Single-mode optical fiberOptical interface
• Line rate:
• 10GE LAN PHY: 10.3125 Gbps (pass-through)
• G.709 LAN PHYwithout fixed stuff bytes: 11.049 Gbps
• G.709 LAN PHYwith fixed stuff bytes: 11.0957 Gbps
• Transmit line rate deviation: G.709 LAN PHYmodes: +/-20 ppm
• Dispersion window: +/-1200 ps/nm or +/-1600 ps/nm (maximum)
• FEC type (software selectable): Generic Reed-Solomon RS (255, 239) code computed asspecified in Annex A/G. 709 (GFEC) or enhanced (EFEC)
Line interface
Copyright © 2017, Juniper Networks, Inc.40
T4000 Core Router Interface Module Reference
Table 34: 10-Gigabit Ethernet DWDMOTNOptical Interface Specifications (continued)
• Transmitter type: LiNbO3MZI (Lithium Niobate Mach-Zehnder Inferometer)
• Modulation format: Nonretum-to-zero (NRZ)
• Channel-plan wavelength range: 1528.77 through 1563.86 nm
• Channel-plan frequency range: 191.7 through 196.1 THz
• Channel spacing: 50 GHz
• Channel tunability: 89 channels—see Table 35 on page 43
• Output power (on): +3 to +7 dBm
• Output power (off): ≤−40 dBm
• Output power stability: −1.5 to +1.0 dB
• Wavelength accuracy: +/-25 pm, +/-3.125 GHz
• Tuning time: Warm tune – 10 seconds; cold start – 40 seconds
• Extinction ratio: ≥ 11 dB
• Crossing ratio: 45 to 55 percent
• Side-mode suppression ratio: ≥ 30 dB
• Optical spectral width: ≤ 25 GHz (informational, not a specification)
• Average relative intensity noise (RIN):
• 10 MHz to 1 GHz: −110 dB/Hz
• 1 GHz to 10 GHz: −145 dB/Hz
• Output OSNR:
• Minimum: 50 dB (0.1 nm resolution bandwidth)
• Typical: 55 dB (0.1 nm resolution bandwidth)
• Polarization extinction ratio: 20 dB
• Eyemask compliance: 802.3—2005
• Jitter generation compliance: GR-253/G.8251
Optical transmitter
• Receiver type: Avalanche photodiode (APD)
• Average receive power (input power range): see Input Power Range in Table 36 on page 44
• Jitter tolerance compliance: GR-253/G.8251/802.3ae (LAN PHY)
• Rx DTV setting:
• No FEC (pass-through): Static (factory optimized value)
• GFEC: Managed by electronic dispersion compensation (EDC)
• EFEC: Managed by EDC
• Rx wavelength range: 1527 to 1567 nm
• Overload (receiver saturation): −5 dBm (high OSNR), −8 dBm (low OSNR)
• Damage input power: +5 dBm
• Optical return loss: ≥ 27 dB
Optical receiver
41Copyright © 2017, Juniper Networks, Inc.
Chapter 2: Network Interface Specifications
Table 34: 10-Gigabit Ethernet DWDMOTNOptical Interface Specifications (continued)
Optical Applications—Power-Limited Receiver (High OSNR):
• Sensitivity:
• No FEC: −5 to −24 dBm (>33 dB/0.1 nmOSNR, 0 ps/nm CD) at 10−12 BER (10.3 Gbps)
• GFEC: −5 to −28 dBm at 8 x 10−5 pre-FEC BER (>33 dB/0.1 nmOSNR, 0 ps/nm CD) (10−15
post-FEC BER) (11.05 and 11.1 Gbps)
• EFEC: −5 to −28 dBm at 1 x 10−3 pre-FEC BER (>33 dB/0.1 nmOSNR, 0 ps/nm CD) (10−15
post-FEC BER) (11.05 and 11.1 Gbps)
• Chromatic dispersion (CD) power penalty:
• No FEC: 3 dB (typical penalty at +/-1200 ps/nmwithout EDC)
• GFEC or EFEC: 3 dB (typical penalty at +/-1600 ps/nmwith EDC)
Optical Applications—Noise-Limited Receiver (Low OSNR):
• Required OSNR:
• No FEC (10.3 Gbps):• 26 dB/0.1 nm (−8 to −22 dBm Rx input power range, 0 ps/nm CD, at 10−12 BER)
• 26 dB/0.1 nm (−8 to −20dBmRx input power range, +/-1000ps/nmwithout EDC, at 10−12
BER)
• 30 dB/0.1 nm (−8 to −20 dBmRx input power range, +/-1200 ps/nmwithout EDC, at 10−12
BER)
• GFEC (11.05 and 11.1 Gbps):• 15.5 dB/0.1 nm (−8 to −20 dBm Rx input power range, 0 ps/nm, at ≤ 10−5 pre-FEC BER, ≤10−15 post-FEC BER)
• 17 dB/0.1 nm (−8 to −20 dBm Rx input power range, +/-1200 ps/nmwith EDC, at ≤ 10−5
pre-FEC BER, ≤ 10−15post-FEC BER)
• EFEC (11.05 and 11.1 Gbps):• 12 dB/0.1 nm (−8 to −20 dBm Rx input power range, 0 ps/nm, at ≤ 10−4pre-FEC BER, ≤10−15post-FEC BER)
• 14 dB/0.1 nm (−8 to −20 dBm Rx input power range, +/-1200 ps/nmwith EDC, at ≤ 10−4
pre-FEC BER, ≤ 10−15post-FEC BER)
• 16 dB/0.1 nm (−8 to −20 dBm Rx input power range, 0 ps/nm CD, 10−15post-FEC BER)
• CDOSNR penalty:
• GFEC: 1.5 dB (typical penalty at +/-1200 ps/nmwith Rx input power range from −8 to −20dBm).
• EFEC: 2 dB (typical penalty at +/-1200 ps/nmwith Rx input power range from −8 to −20dBm).
For more detailed information, see Table 36 on page 44.
Optical performance
10-Gigabit Ethernet DWDMOTNSupportedWavelengths
Table 35 on page 43 provides the supported wavelengths for the 100-GHz grid and the
50-GHz offset in both THz and nm.
Copyright © 2017, Juniper Networks, Inc.42
T4000 Core Router Interface Module Reference
Table 35: 10-Gigabit Ethernet DWDMOTNSupportedWavelengths
50–GHz Offset100–GHz Grid50–GHz Offset100–GHz Grid
nmTHznmTHznmTHznmTHz
1544.92194.051545.32194.001563.45191.751563.86191.70
1544.12194.151544.52194.101562.63191.851563.04191.80
1543.33194.251543.73194.201561.82191.951562.23191.90
1542.53194.351542.93194.301561.01192.051561.41192.00
1541.74194.451542.14194.401560.20192.151560.60192.10
1540.95194.551541.34194.501559.38192.251559.79192.20
1540.16194.651540.55194.601558.57192.351558.98192.30
1539.37194.751539.76194.701557.76192.451558.17192.40
1538.58194.851538.97194.801556.95192.551557.36192.50
1537.79194.951538.18194.901556.15192.651556.55192.60
1537.00195.051537.39195.001555.34192.751555.74192.70
1536.21195.151536.60195.101554.53192.851554.94192.80
1535.42195.251535.82195.201553.73192.951554.13192.90
1534.64195.351535.03195.301552.92193.051553.32193.00
1533.85195.451534.25195.401552.12193.151552.52193.10
1533.07195.551533.46195.501551.31193.251551.72193.20
1532.28195.651532.68195.601550.51193.351550.91193.30
1531.50195.751531.89195.701549.71193.451550.11193.40
1530.72195.851531.11195.801548.91193.551549.31193.50
1529.94195.951530.33195.901548.11193.651548.51193.60
1529.16196.051529.55196.001547.31193.751547.71193.70
1528.77196.101546.51193.851546.91193.80
1545.72193.951546.11193.90
43Copyright © 2017, Juniper Networks, Inc.
Chapter 2: Network Interface Specifications
PC-1XGE-DWDM-OTNOptical Signal-to-Noise Ratio (OSNR) Performance
TheOSNRperformance listed in Table 36onpage44 is for an appropriate level of optical
filteringof theamplified spontaneousemission (ASE) reaching the receiver and is derived
using a 0.22-nm 3-dB full-width Gaussian filter. When no FEC is used, there is no OTN
framing.
Table 36: PC-1XGE-DWDM-OTNOptical Signal-to-Noise Ratio (OSNR) Performance
CD Tolerance(ps/nm)
Input-PowerRange(ROP)(dBm)
Post-FECBER
Pre-FECBERFEC Type
OSNR(dB/0.5 nm)
OSNR (dB/0.1nm)
0–5 to –24NA10–12None2633
+/-1200 (no EDC)–5 to –21NA10–12None2633
0–8 to –22NA10–12None1926
+/-1000 (no EDC)–8 to –20NA10–12None1926
+/-1200 (no EDC)–8 to –20NA10–12None2330
0–5 to –2810–158 x 10–5GFEC2633
+/-1600 (with EDC)–5 to –2510–158 x 10–5GFEC2633
0–8 to –2010–1510–5GFEC8.515.5
+/-1200 (with EDC)–8 to –2010–1510–5GFEC1017
0–5 to –2810–1510–3EFEC2633
+/-1600 (with EDC)–5 to –2510–1510–3EFEC2633
0–8 to –2010–157 x 10–4EFEC512
+/-1200 (with EDC)–8 to –2010–157 x 10–4EFEC714
RelatedDocumentation
Supported Network Interface Standards by Transceiver for ACX Series, M Series, MX
Series, and T Series Routers on page 17
•
10-Gigabit Ethernet DWDMTransceiverWavelengths
Table 37 on page 45 provides the supported wavelengths for the 100-GHz grid and the
50-GHz offset in both THz and nm.
Copyright © 2017, Juniper Networks, Inc.44
T4000 Core Router Interface Module Reference
Table 37: ProgrammableWavelengths Supported by 10-Gigabit Ethernet DWDMTransceivers
50–GHz Offset100–GHz Grid50–GHz Offset100–GHz Grid
nmTHznmTHznmTHznmTHz
1544.92194.051545.32194.001563.45191.751563.86191.70
1544.12194.151544.52194.101562.63191.851563.04191.80
1543.33194.251543.73194.201561.82191.951562.23191.90
1542.53194.351542.93194.301561.01192.051561.41192.00
1541.74194.451542.14194.401560.20192.151560.60192.10
1540.95194.551541.34194.501559.38192.251559.79192.20
1540.16194.651540.55194.601558.57192.351558.98192.30
1539.37194.751539.76194.701557.76192.451558.17192.40
1538.58194.851538.97194.801556.95192.551557.36192.50
1537.79194.951538.18194.901556.15192.651556.55192.60
1537.00195.051537.39195.001555.34192.751555.74192.70
1536.21195.151536.60195.101554.53192.851554.94192.80
1535.42195.251535.82195.201553.73192.951554.13192.90
1534.64195.351535.03195.301552.92193.051553.32193.00
1533.85195.451534.25195.401552.12193.151552.52193.10
1533.07195.551533.46195.501551.31193.251551.72193.20
1532.28195.651532.68195.601550.51193.351550.91193.30
1531.50195.751531.89195.701549.71193.451550.11193.40
1530.72195.851531.11195.801548.91193.551549.31193.50
1529.94195.951530.33195.901548.11193.651548.51193.60
1529.16196.051529.55196.001547.31193.751547.71193.70
1528.77196.101546.51193.851546.91193.80
1545.72193.951546.11193.90
45Copyright © 2017, Juniper Networks, Inc.
Chapter 2: Network Interface Specifications
RelatedDocumentation
Ethernet DWDM InterfaceWavelength Overview
Configuring the 10-Gigabit or 100-Gigabit Ethernet DWDM InterfaceWavelength
•
• Network Cable and Transceiver Overview for ACXSeries, MSeries, andMXSeries Routers
• Supported Network Interface Standards by Transceiver for ACX Series, M Series, MX
Series, and T Series Routers on page 17
40-Gigabit Ethernet 40GBASE-R Optical Interface Specifications
To determine which transceivers support each 40GBASE-R standard, see “Supported
Network Interface Standards by Transceiver for ACX Series, M Series, MX Series, and T
Series Routers” on page 17. The “Cables and Connectors” section in the description for
each MIC or PIC lists which standards and transceivers are supported for that device.
The specifications are organized by distance supported.
• 40GBASE-SR4 Specifications on page 46
• 40GBASE-LX4 Specifications on page 47
• 40GBASE-LR4 Specifications on page 48
• 40GBASE-ER4 Specifications on page 48
40GBASE-SR4 Specifications
Table 38 on page 46 shows the optical interface specifications for the 40GBASE-SR4
standard.
Table 38: 40GBASE-SR4Optical Interface Specifications
40GBASE-SR4Parameter
MultimodeOptical interface
IEEE 802.3ba-2010Standard
OM3MMF cable, 100m (328 ft)
OM4MMF cable, 150m (492 ft)
Maximum distance
840 through 860 nmTransmitter wavelength per lane
–7.6 through 2.4 dBmAverage launch power per lane
–9.5 through 2.4 dBmAverage receive power per lane
–5.4 dBmStressed receiver sensitivity (OMA) per lane(maximum)
Copyright © 2017, Juniper Networks, Inc.46
T4000 Core Router Interface Module Reference
40GBASE-LX4 Specifications
Table 39 on page 47 shows the optical interface specifications for the Juniper Networks
proprietary 40GBASE-LX4.
Table 39: 40GBASE-LX4Optical Interface Specifications
40GBASE-LX4Parameter
10.3125 GBd +/-100 ppmSignaling rate,each lane (range)
Dual LC/PCConnector type
1Fiber pairs
Lane 0–1264.5 nm through 1277.5 nm
Lane 1–1284.5 nm through 1297.5 nm
Lane 2–1304.5 nm through 1317.5 nm
Lane 3–1324.5 nm through 1337.5 nm
Transmit andreceive lanewavelengths
-9.0 dBm
-7.0 dBm
SMF
MMF
Average transmitlaunchpower, eachlane (minimum)
2.3 dBm
4.3 dBm
SMF
MMF
Average transmitlaunchpower, eachlane (maximum)
-12 dBm
-10.0 dBm
SMF
MMF
Average receivepower, each lane(minimum)
2.3 dBm
4.3 dBm
SMF
MMF
Average receivepower, each lane(maximum)
-10.5 dBm
-10.5 dBm
SMF
MMF
Receiver sensitivity(OMA), each lane(maximum)
47Copyright © 2017, Juniper Networks, Inc.
Chapter 2: Network Interface Specifications
Table 39: 40GBASE-LX4Optical Interface Specifications (continued)
40GBASE-LX4Parameter
MMFMMFSMFFiber type
50/125 µm50/125 µm9/125 µmCore/cladding size
OM4OM3OS1Fiber grade
4700MHzx km2000MHzxkm–Effective modalbandwidth at850 nm
150m (492 ft)100m (328 ft)2 km(1.24 miles)
Operating distance
40GBASE-LR4 Specifications
Table 40 on page 48 shows the optical interface specifications for the 40GBASE-LR4
standard.
Table 40: 40GBASE-LR4Optical Interface Specifications
40GBASE-LR4Parameter
Single modeOptical interface
IEEE 802.3ba-2010Standard
9/125 SMF cable: 10 km (6.2 miles)Maximum distance
1264.5 through 1277.5 nm
1284.5 through 1297.5 nm
1304.5 through 1317.5 nm
1324.5 through 1337.5 nm
Transmitter wavelength per lane
–7 through 2.3 dBmAverage launch power per lane
8.3 dBmTotal average launch power (maximum)
–13.7 through 2.3 dBmAverage receive power per lane
–11.5 dBmReceiver sensitivity (OMA) per lane(maximum)
40GBASE-ER4 Specifications
Table 41 on page 49 shows the optical interface specifications for the 40GBASE-ER4
standard.
Copyright © 2017, Juniper Networks, Inc.48
T4000 Core Router Interface Module Reference
Table 41: 40GBASE-ER4Optical Interface Specifications
40GBASE-ER4Parameter
Single modeOptical interface
IEEE 802.3bm-2015Standard
9/125 SMF cable: 40 km (24.8 miles)Maximum distance
1264.5 through 1277.5 nm
1284.5 through 1297.5 nm
1304.5 through 1317.5 nm
1324.5 through 1337.5 nm
Transmitter wavelength per lane
–2.7 through 4.5 dBmAverage launch power per lane
4.5 dBmTotal average launch power (maximum)
–21.2 through -4.5 dBmAverage receive power per lane
–19 dBmReceiver sensitivity (OMA) per lane(maximum)
100-Gigabit Ethernet 100GBASE-R Optical Interface Specifications
To determine which transceivers support each 100GBASE-R standard, see “Supported
Network Interface Standards by Transceiver for ACX Series, M Series, MX Series, and T
Series Routers” on page 17. The “Cables and Connectors” section in the description for
each MIC or PIC lists which standards and transceivers are supported for that device.
The specifications are organized by distance supported.
NOTE: The CFP-100GBASE-ZR transceiver is not supported on the T1600and T4000 routers.
• 100GBASE-SR10 Specifications on page 49
• 100GBASE-SR4 Specifications on page 50
• 100GBASE-LR4 Specifications on page 50
• 100GBASE-ER4 Specifications on page 51
• Juniper Networks Specifications for CFP-100GBASE-ZR on page 52
100GBASE-SR10 Specifications
Table 42 on page 50 shows the optical interface specifications for the 100GBASE-SR10
standard.
49Copyright © 2017, Juniper Networks, Inc.
Chapter 2: Network Interface Specifications
Table 42: 100GBASE-SR10 Optical Interface Specifications
100GBASE-SR10Parameter
MultimodeOptical interface
IEEE 802.3ba—2010Standard
OM3MMF cable, 100m (328 ft)
OM4MMF cable, 150m (492 ft)
Maximum distance
840 through 860 nmTransmitter wavelength per lane
–7.6 through 2.4 dBmAverage launch power per lane
–9.5 through 2.4 dBmAverage receive power per lane
–5.4 dBmStressed receiver sensitivity (OMA) per lane(maximum)
100GBASE-SR4 Specifications
Table 43 on page 50 shows the optical interface specifications for the 100GBASE-SR4
standard.
Table 43: 100GBASE-SR4Optical Interface Specifications
100GBASE-SR4Parameter
MultimodeOptical interface
IEEE 802.3bmStandard
OM3MMF cable, 70m (230 feet)
OM4MMF cable, 100m (328 feet)
Maximum distance
840 through 860 nmTransmitter wavelength per lane
–8.4 through 2.4 dBmAverage launch power per lane
–10.3 through 2.4 dBmAverage receive power per lane
–5.2 dBmStressed receiver sensitivity (OMA), eachlane (maximum)
100GBASE-LR4 Specifications
Table 44 on page 51 shows the optical interface specifications for the 100GBASE-LR4
standard.
Copyright © 2017, Juniper Networks, Inc.50
T4000 Core Router Interface Module Reference
Table 44: 100GBASE-LR4Optical Interface Specifications
100GBASE-LR4Parameter
Single-modeOptical interface
IEEE 802.3ba-2010Standard
9/125 SMF cable, 10 km (6.2 miles)Maximum distance
1294.53 through 1296.59 nm
1299.02 through 1301.09 nm
1303.54 through 1305.63 nm
1308.09 through 1310.19 nm
Transmitter wavelength per lane
minimum: -4.3 dBm (0.37 mW)
maximum: 4.5 dBm (2.82mW)
TX power per lane
minimum: -10.5 dBm (0.09mW)
maximum: 4.5 dBm (2.82mW)
RX power per lane
minimum: 1.7 dBm (1.48mW)
maximum: 10.5 dBm (11.28mW)
Total TX power
minimum: -4.4 dBm (0.36mW)
maximum: 10.5 dBm (11.28mW)
Total RX power
–8.6 dBmReceiver sensitivity (OMA) per lane(maximum)
100GBASE-ER4 Specifications
Table 45 on page 51 shows the optical interface specifications for the 100GBASE-ER4
standard.
Table 45: 100GBASE-ER4Optical Interface Specifications
100GBASE-ER4Parameter
Single-modeOptical interface
IEEE 802.3ba-2010Standard
SMF cable, 40 km (24.9 miles)Maximum distance
51Copyright © 2017, Juniper Networks, Inc.
Chapter 2: Network Interface Specifications
Table 45: 100GBASE-ER4Optical Interface Specifications (continued)
100GBASE-ER4Parameter
1294.53 through 1296.59 nm
1299.02 through 1301.09 nm
1303.54 through 1305.63 nm
1308.09 through 1310.19 nm
Transmitter wavelength per lane
–2.9 through 2.9 dBmAverage launch power per lane
–20.9 through 4.5 dBmAverage receive power per lane
–21.4 dBmReceiver sensitivity (OMA) per lane(maximum)
Juniper Networks Specifications for CFP-100GBASE-ZR
The CFP-100GBASE-ZR transceiver is not specified as part of IEEE 802.3 but is built
according to Juniper Networks specifications.
Table46onpage52shows theoptical interfacespecifications for theCFP-100GBASE-ZR
transceiver.
Table 46: Juniper Networks Optical Interface Specifications forCFP-100GBASE-ZR
CFP-100GBASE-ZRParameter
Single-modeOptical interface
ProprietaryDualpolarization-quadraturephaseshift keying(DP-QPSK)with forwarderrorcorrection(FEC)
Standard
80 km (49.7 miles)Greater reach possible with link engineering
Maximum distance
120.579 GbpsLine rate
193.90 THz (+/-1.8 GHz) / 1546.119 nmTransmitter frequency / wavelength
+5 dBmTransmit output power (enabled)
–40 dBmTransmit output power (disabled)
193.90 THz (+/-1.8 GHz) / 1546.119 nmReceive frequency / wavelength
–20 through +5 dBmReceive input optical power range
+10 dBmReceive input optical power damage threshold
Copyright © 2017, Juniper Networks, Inc.52
T4000 Core Router Interface Module Reference
Table 46: Juniper Networks Optical Interface Specifications forCFP-100GBASE-ZR (continued)
CFP-100GBASE-ZRParameter
+/-2500 ps/nmReceive chromatic dispersion (CD) tolerance
15 ps (mean DGD)Receive polarization mode dispersion (PMD)tolerance
50 krad/sReceive polarization tracking
RelatedDocumentation
Supported Network Interface Standards by Transceiver for ACX Series, M Series, MX
Series, and T Series Routers on page 17
•
SONET/SDHOC3/STM1 Optical Interface Specifications
The SONET/SDHOC3/STM1 standards are supported on M Series routers, MX Series
routers, and T Series routers.
To determine which transceivers support each SONET/SDHOC3/STM1 standard, see
“Supported Network Interface Standards by Transceiver for ACX Series, M Series, MX
Series, and T Series Routers” on page 17. The “Cables and connectors” section in the
description for each MIC or PIC lists which standards and transceivers are supported for
that device.
The specifications are organized by distance supported.
• SONET/SDHOC3/STM1 Specifications on page 53
• SONET/SDHOC3/STM1 Intermediate Reach (IR-1) Specifications on page 54
• SONET/SDHOC3/STM1 Long Reach (LR-1) Specifications on page 54
SONET/SDHOC3/STM1 Specifications
Table 47 on page 53 shows themultimode SONET/SDHOC3/STM1 optical interface
specifications.
Table 47: SONET/SDHOC3/STM1Multimode Optical InterfaceSpecifications
MultimodeParameter
MultimodeOptical interface
MMF cable: 1.2 miles (2 km)Maximum distance
Multivendor agreementStandard
1270 through 1380 nmTransmitter wavelength
53Copyright © 2017, Juniper Networks, Inc.
Chapter 2: Network Interface Specifications
Table 47: SONET/SDHOC3/STM1Multimode Optical InterfaceSpecifications (continued)
MultimodeParameter
–20 through –14 dBmAverage launch power
–14 dBmReceiver saturation
–30 dBmReceiver sensitivity
SONET/SDHOC3/STM1 Intermediate Reach (IR-1) Specifications
Table48onpage54shows theSONET/SDHOC3/STM1 intermediate reach (IR-1)optical
interface specifications.
Table 48: SONET/SDHOC3/STM1 Intermediate Reach Optical InterfaceSpecifications
Intermediate Reach (IR-1)Parameter
Single-modeOptical interface
SMF cable: 9.3 miles (15 km)Maximum distance
Telcordia GR-253Standard
1261 through 1360 nmTransmitter wavelength
–15 through –8 dBmAverage launch power
–8 dBmReceiver saturation
–28 dBmReceiver sensitivity
SONET/SDHOC3/STM1 Long Reach (LR-1) Specifications
Table49onpage54showstheSONET/SDHOC3/STM1 long reach(LR-1)optical interface
specifications.
Table 49: SONET/SDHOC3/STM1 Long Reach -1 Optical InterfaceSpecifications
Long Reach (LR-1)Parameter
Single-modeOptical interface
SMF cable: 24.85miles (40 km)Maximum distance
Telcordia GR-253Standard
1263 through 1360 nmTransmitter wavelength
Copyright © 2017, Juniper Networks, Inc.54
T4000 Core Router Interface Module Reference
Table 49: SONET/SDHOC3/STM1 Long Reach -1 Optical InterfaceSpecifications (continued)
Long Reach (LR-1)Parameter
–5 through 0 dBmAverage launch power
–10 dBmReceiver saturation
–34 dBmReceiver sensitivity
RelatedDocumentation
Supported Network Interface Standards by Transceiver for ACX Series, M Series, MX
Series, and T Series Routers on page 17
•
SONET/SDHOC12/STM4Optical Interface Specifications
The SONET/SDHOC12/STM4 optical interface standards are supported on M Series
routers, MX Series routers, and T Series routers.
To determine which transceivers support each SONET/SDHOC12/STM4 standard, see
“Supported Network Interface Standards by Transceiver for ACX Series, M Series, MX
Series, and T Series Routers” on page 17. The “Cables and connectors” section in the
description for each MIC or PIC lists which standards and transceivers are supported for
that device.
The specifications are organized by distance supported.
• SONET/SDHOC12/STM4 Short Reach (SR-1) Specifications on page 55
• SONET/SDHOC12/STM4 Intermediate Reach (IR-1) Specifications on page 56
• SONET/SDHOC12/STM4 Long Reach (LR-1) Specifications on page 56
• SONET/SDHOC12/STM4 Long Reach (LR-2) Specifications on page 57
SONET/SDHOC12/STM4 Short Reach (SR-1) Specifications
Table 50 on page 55 shows the SONET/SDHOC12/STM4 short reach (SR-1) optical
interface specifications.
Table 50: SONET/SDHOC12/STM4ShortReach (SR-1)Optical InterfaceSpecifications
Short Reach (SR-1)Parameter
Single-modeOptical interface
SMF cable: 1.24 miles (2 km)Maximum distance
Telcordia GR-253Standard
1261 through 1360 nmTransmitter wavelength
55Copyright © 2017, Juniper Networks, Inc.
Chapter 2: Network Interface Specifications
Table 50: SONET/SDHOC12/STM4ShortReach (SR-1)Optical InterfaceSpecifications (continued)
Short Reach (SR-1)Parameter
–15 through –8 dBmAverage launch power
–8 dBmReceiver saturation
–23 dBmReceiver sensitivity
SONET/SDHOC12/STM4 Intermediate Reach (IR-1) Specifications
Table 51 on page 56 shows the SONET/SDHOC12/STM4 short reach (IR-1) optical
interface specifications.
Table 51: SONET/SDHOC12/STM4 Intermediate Reach (IR-1) OpticalInterface Specifications
Intermediate Reach (IR-1)Parameter
Single-modeOptical interface
SMF cable: 9.3 miles (15 km)Maximum distance
Telcordia GR-253Standard
1274 through 1356 nmTransmitter wavelength
–15 through –8 dBmAverage launch power
–8 dBmReceiver saturation
–28 dBmReceiver sensitivity
SONET/SDHOC12/STM4 Long Reach (LR-1) Specifications
Table 52 on page 56 shows the SONET/SDHOC12/STM4 short reach (LR-1) optical
interface specifications.
Table 52: SONET/SDHOC12/STM4 Long Reach (LR-1) Optical InterfaceSpecifications
Long Reach (LR-1)Parameter
Single-modeOptical interface
SMF cable: 24.85miles (40 km)Maximum distance
Telcordia GR-253Standard
1280 through 1335 nmTransmitter wavelength
Copyright © 2017, Juniper Networks, Inc.56
T4000 Core Router Interface Module Reference
Table 52: SONET/SDHOC12/STM4 Long Reach (LR-1) Optical InterfaceSpecifications (continued)
Long Reach (LR-1)Parameter
–3 through +2 dBmAverage launch power
–8 dBmReceiver saturation
–28 dBmReceiver sensitivity
SONET/SDHOC12/STM4 Long Reach (LR-2) Specifications
Table 53 on page 57 shows the SONET/SDHOC12/STM4 short reach (LR-2) optical
interface specifications.
Table 53: SONET/SDHOC12/STM4 Long Reach (LR-2) Optical InterfaceSpecifications
Long Reach (LR-2)Parameter
Single-modeOptical interface
SMF cable: 49.70miles (80 km)Maximum distance
Telcordia GR-253Standard
1480 through 1580 nmTransmitter wavelength
–3 through 2 dBmAverage launch power
–8 dBmReceiver saturation
–28 through –8 dBmReceiver sensitivity
RelatedDocumentation
Supported Network Interface Standards by Transceiver for ACX Series, M Series, MX
Series, and T Series Routers on page 17
•
SONET/SDHOC48/STM16Optical Interface Specifications
TheSONET/SDHOC48/STM16 standards are supported onM40e routers,M120 routers,
M320 routers, MX Series routers, and T Series routers.
To determinewhich transceivers support each SONET/SDHOC48/STM16 standard, see
“Supported Network Interface Standards by Transceiver for ACX Series, M Series, MX
Series, and T Series Routers” on page 17. The “Cables and connectors” section in the
description for each MIC or PIC lists which standards and transceivers are supported for
that device.
57Copyright © 2017, Juniper Networks, Inc.
Chapter 2: Network Interface Specifications
The specifications are organized by distance supported.
• SONET/SDHOC48/STM16 Short Reach (SR-1) Specifications on page 58
• SONET/SDHOC48/STM16 Intermediate Reach (IR-1) Specifications on page 58
• SONET/SDHOC48/STM16 Long Reach (LR-1) Specifications on page 59
• SONET/SDHOC48/STM16 Long Reach (LR-2) Specifications on page 59
SONET/SDHOC48/STM16 Short Reach (SR-1) Specifications
Table 54 on page 58 shows the SONET/SDHOC48/STM16 short reach (SR-1) optical
interface specifications.
Table54:SONET/SDHOC48/STM16ShortReach(SR-1)Optical InterfaceSpecifications
Short Reach (SR-1)Parameter
Single-modeOptical interface
SMF cable: 1.24 miles (2 km)Maximum distance
Telcordia GR-253Standard
1266 through 1360 nmTransmitter wavelength
–10 through –3 dBmAverage launch power
–3 dBmReceiver saturation
–18 dBmReceiver sensitivity
SONET/SDHOC48/STM16 Intermediate Reach (IR-1) Specifications
Table 55 on page 58 shows the SONET/SDHOC48/STM16 intermediate reach (IR-1)
optical interface specifications.
Table 55: SONET/SDHOC48/STM16 Intermediate Reach (IR-1) OpticalInterface Specifications
Intermediate Reach (IR-1)Parameter
Single-modeOptical interface
SMF cable: 9.3 miles (15 km)Maximum distance
Telcordia GR-253Standard
1260 through 1360 nmTransmitter wavelength
–5 through 0 dBmAverage launch power
Copyright © 2017, Juniper Networks, Inc.58
T4000 Core Router Interface Module Reference
Table 55: SONET/SDHOC48/STM16 Intermediate Reach (IR-1) OpticalInterface Specifications (continued)
Intermediate Reach (IR-1)Parameter
0 dBmReceiver saturation
–18 dBmReceiver sensitivity
SONET/SDHOC48/STM16 Long Reach (LR-1) Specifications
Table 56 on page 59 shows the SONET/SDHOC48/STM16 long reach (LR-1) optical
interface specifications.
Table56:SONET/SDHOC48/STM16LongReach(LR-1)Optical InterfaceSpecifications
Long Reach (LR-1)Parameter
Single-modeOptical interface
SMF cable: 28.85miles (40 km)Maximum distance
Telcordia GR-253Standard
1280 through 1335 nmTransmitter wavelength
–2 through +3 dBmAverage launch power
–9 dBmReceiver saturation
–28 dBmReceiver sensitivity
SONET/SDHOC48/STM16 Long Reach (LR-2) Specifications
Table 57 on page 59 shows the SONET/SDHOC48/STM16 long reach (LR-2) optical
interface specifications.
Table57:SONET/SDHOC48/STM16LongReach(LR-2)Optical InterfaceSpecifications
Long Reach (LR-2)Parameter
Single-modeOptical interface
SMF cable: 49.71 miles (80 km)Maximum distance
Telcordia GR-253Standard
1500 through 1580 nmTransmitter wavelength
–2 through +3 dBmAverage launch power
59Copyright © 2017, Juniper Networks, Inc.
Chapter 2: Network Interface Specifications
Table57:SONET/SDHOC48/STM16LongReach(LR-2)Optical InterfaceSpecifications (continued)
Long Reach (LR-2)Parameter
–9 dBmReceiver saturation
–28 dBmReceiver sensitivity
RelatedDocumentation
Supported Network Interface Standards by Transceiver for ACX Series, M Series, MX
Series, and T Series Routers on page 17
•
SONET/SDHOC192/STM64Optical Interface Specifications
TheSONET/SDHOC192/STM64standardsare supportedonM120 routers,M320 routers,
MX Series routers, and T Series routers.
To determine which transceivers support the SONET/SDHOC192/STM64 standard, see
“Supported Network Interface Standards by Transceiver for ACX Series, M Series, MX
Series, and T Series Routers” on page 17. The “Cables and connectors” section in the
description for each MIC or PIC lists which standards and transceivers are supported for
that device.
The specifications are organized by distance supported.
• SONET/SDHOC192/STM64 Very Short Reach (VSR) on page 60
• SONET/SDHOC192/STM64 Short Reach (SR-1) on page 61
• SONET/SDHOC192/STM64 Short Reach (SR-2) on page 61
• SONET/SDHOC192/STM64 Intermediate Reach (IR-2) on page 62
• SONET/SDHOC192/STM64 Long reach (LR-1) on page 62
• SONET/SDHOC192/STM64 Long reach (LR-2) on page 63
SONET/SDHOC192/STM64 Very Short Reach (VSR)
Table 58 on page 60 shows the SONET/SDHOC192/STM64 very short reach (VSR)
optical interface specifications.
Table 58: SONET/SDHOC192/STM64 Very Short Reach (VSR 1) OpticalInterface Specifications
Very Short Reach (VSR)Parameter
MultimodeOptical interface
MMF cable: 984.25 feet (300m)Maximum distance
OIF VSR4–1Standard
830 through 860 nmTransmitter wavelength
Copyright © 2017, Juniper Networks, Inc.60
T4000 Core Router Interface Module Reference
Table 58: SONET/SDHOC192/STM64 Very Short Reach (VSR 1) OpticalInterface Specifications (continued)
Very Short Reach (VSR)Parameter
–10 through –3 dBmAverage launch power
–3 dBmReceiver saturation
–16 dBmReceiver sensitivity
SONET/SDHOC192/STM64 Short Reach (SR-1)
Table 59 on page 61 shows the SONET/SDHOC192/STM64 short reach (SR-1) optical
interface specifications.
Table 59: SONET/SDHOC192/STM64 Short Reach (SR-1) OpticalInterface Specifications
Short Reach (SR-1)Parameter
Single-modeOptical interface
SMF cable: 6.21 miles (10 km)Maximum distance
Telcordia GR-253 OC192 SR1Standard
1290 nm through 1330 nmTransmitter wavelength
–6 through –1 dBmAverage launch power
–1.0 dBmReceiver saturation
–11 dBmReceiver sensitivity
SONET/SDHOC192/STM64 Short Reach (SR-2)
Table 60 on page 61 shows the SONET/SDHOC192/STM64 short reach (SR-2) optical
interface specifications.
Table 60: SONET/SDHOC192/STM64 Short Reach (SR-2) OpticalInterface Specifications
Short Reach (SR-2)Parameter
Single-modeOptical interface
SMF cable: 15.5 miles (25 km)Maximum distance
Telcordia GR-253 OC192 SR2Standard
1530 through 1565 nmTransmitter wavelength
61Copyright © 2017, Juniper Networks, Inc.
Chapter 2: Network Interface Specifications
Table 60: SONET/SDHOC192/STM64 Short Reach (SR-2) OpticalInterface Specifications (continued)
Short Reach (SR-2)Parameter
–4 through 0 dBmAverage launch power
–3 dBmReceiver saturation
–14 dBmReceiver sensitivity
SONET/SDHOC192/STM64 Intermediate Reach (IR-2)
Table 61 on page 62 shows the SONET/SDHOC192/STM64 Intermediate reach (IR-2)
optical interface specifications.
Table 61: SONET/SDHOC192/STM64 Intermediate Reach (IR-2)OpticalInterface Specifications
Intermediate Reach (IR-2)Parameter
Single-modeOptical interface
SMF cable: 24.8 miles (40 km)
NOTE: Distancesgreater than30kmareconsideredto be engineered links.
Maximum distance
Telcordia GR-253 OC192 IR2Standard
1530 nm through 1565 nmTransmitter wavelength
–1.0. through 2 dBmAverage launch power
–1.0 dBmReceiver saturation
–14 dBmReceiver sensitivity
SONET/SDHOC192/STM64 Long reach (LR-1)
Table 62 on page 62 shows the SONET/SDHOC192/STM64 long reach (LR-1) optical
interface specifications.
Table62:SONET/SDHOC192/STM64LongReach(LR-1)Optical InterfaceSpecifications
Long Reach (LR-1)Parameter
Single-modeOptical interface
SMF cable: 49.71 miles (80 km)Maximum distance
Copyright © 2017, Juniper Networks, Inc.62
T4000 Core Router Interface Module Reference
Table62:SONET/SDHOC192/STM64LongReach(LR-1)Optical InterfaceSpecifications (continued)
Long Reach (LR-1)Parameter
Telcordia GR-253 OC192 LR2Standard
1530 nm through 1565 nmTransmitter wavelength
6 through 8 dBmAverage launch power
–10 dBmReceiver saturation
–22 dBmReceiver sensitivity
SONET/SDHOC192/STM64 Long reach (LR-2)
Table 63 on page 63 shows the SONET/SDHOC192/STM64 long reach (LR-2) optical
interface specifications.
Table 63: SONET/SDHOC192/STM64 Long Reach (LR-2) OpticalInterface Specifications
Long Reach (LR-2)Parameter
Single-modeOptical interface
SMF cable: 49.71 miles (80 km)Maximum distance
Telcordia GR-253 OC192 LR2Standard
1530 nm through 1565 nmTransmitter wavelength
0 through 4 dBmAverage launch power
–7 dBmReceiver saturation
–24 dBmReceiver sensitivity
RelatedDocumentation
Supported Network Interface Standards by Transceiver for ACX Series, M Series, MX
Series, and T Series Routers on page 17
•
SONET/SDHOC768/STM256Optical Interface Specifications
TheSONET/SDHOC768/STM256PIC is supported on T640 routers, T1600 routers, and
T4000 routers. This PIC has a fixed SONET/SDHOC768/STM256 short reach (SR-1)
optical interface.
To determine which transceivers support each SONET/SDHOC768/STM256 standard,
see “Supported Network Interface Standards by Transceiver for ACX Series, M Series,
63Copyright © 2017, Juniper Networks, Inc.
Chapter 2: Network Interface Specifications
MX Series, and T Series Routers” on page 17. The “Cables and connectors” section in the
description for each PIC lists which standards and transceivers are supported for that
device.
Table 64 on page 64 shows the SONET/SDHOC768/STM256 short reach (SR-1) optical
interface specifications.
Table 64: SONET/SDHOC768/STM256 Short Reach (SR-1) OpticalInterface Specifications
Short Reach (SR-1)Parameter
Single-modeOptical interface
1.24 miles (2 km)Maximum distance
300–pinmulti-sourceagreement (MSA) ITUG.693VSR2000–3R2
Standard
1530 through 1565 nmTransmitter wavelength
0 through +3 dBmAverage launch power
+3 dBmReceiver saturation
–6 dBmReceiver sensitivity
RelatedDocumentation
• Supported Network Interface Standards by Transceiver for ACX Series, M Series, MX
Series, and T Series Routers on page 17
Copyright © 2017, Juniper Networks, Inc.64
T4000 Core Router Interface Module Reference
PART 2
PIC Descriptions
• ATM2 IQ PIC Descriptions on page 67
• Channelized PIC Descriptions on page 73
• Channelized Enhanced IQ (IQE) PIC Descriptions on page 81
• DS3 and E3 PIC Descriptions on page 107
• Fast Ethernet PIC Descriptions on page 111
• Gigabit Ethernet PIC Descriptions on page 113
• 10-Gigabit Ethernet PIC Descriptions on page 127
• 40-Gigabit Ethernet PIC Descriptions on page 151
• 100-Gigabit Ethernet PIC Descriptions on page 155
• Services PIC Descriptions on page 163
• SONET/SDH PIC Descriptions on page 169
• End-of-Life PIC Descriptions on page 199
65Copyright © 2017, Juniper Networks, Inc.
Copyright © 2017, Juniper Networks, Inc.66
T4000 Core Router Interface Module Reference
CHAPTER 3
ATM2 IQ PIC Descriptions
• ATM2 OC12/STM4 IQ PIC (T4000 Router) on page 67
ATM2OC12/STM4 IQ PIC (T4000 Router)
Figure 1: 2-Port ATM2OC12/STM4 IQ PIC
• Software Release on page 67
• Hardware Features on page 67
• Software Features on page 68
• Cables and Connectors on page 70
• LEDs on page 70
• Alarms, Errors, and Events on page 70
Software Release
2-port: Junos OS Release 12.2R2 and later (Type 2)
For information on which FPCs support this PIC, see “T4000 PIC/FPC Compatibility” on
page 8.
Hardware Features
• Two OC12 ports
• Power requirement: 0.52 A@ 48 V (25W)
67Copyright © 2017, Juniper Networks, Inc.
• Fine-grained queuing per logical interface
• Conforms to ANSI T1.105-1991 and T1E1.2/93-020R1
• Complies with ATM and SONET/SDH standards
• Alarm and event counting and detection
• Compatible with well-known ATM switches
• ATM switch ID, which displays the switch IP address and local interface name of the
adjacent Fore ATM switches
• Model number: PB-2OC12-ATM2-SMIR
• ATM2 IQ 2-port OC12 PICs have dual 3010 SAR for segmentation and reassembly into
53-byte ATM cells
• High-performance parsing of SONET/SDH frames
• ASIC-based packet segmentation and reassembly (SAR)management and output
port queuing
• 64MB SDRAMmemory for ATM SAR
• Packet buffering, Layer 2 parsing
Software Features
Table 65: Software Features Supported
T4000 First Supported JunosOS ReleaseSoftware Feature
12.2R2Circuit cross-connect for leveraging ATM access networks
12.2R2User-configurable virtual circuit (VC) and virtual path (VP) support
12.2R2Support for idle cell or unassigned cell transmission
12.2R2OAM fault management processes alarm indication signal (AIS), remote defect indication(RDI), and loop cells
12.2R2Point-to-point and point-to-multipoint mode Layer 2 counters per VC and per VP
12.2R2Local and remote loopback
12.2R2ATM Inverse ARP, which enables routers to automatically learn the IP address of the routeron the far end of an ATM PVC
12.2R2Simple Network Management Protocol (SNMP):
• Management Information Base (MIB) 2 (RFC 1213)
• ATMMIB (RFC 1695)
• SONETMIB
Copyright © 2017, Juniper Networks, Inc.68
T4000 Core Router Interface Module Reference
Table 65: Software Features Supported (continued)
T4000 First Supported JunosOS ReleaseSoftware Feature
12.2R2Unspecified bit rate (UBR), non-real-time variable bit rate (VBR), and constant bit rate(CBR) traffic shaping
12.2R2Per-VC or per-VP traffic shaping
12.2R2Support for F4 OAM cells
12.2R2Support for 16-bit VCI range
69Copyright © 2017, Juniper Networks, Inc.
Chapter 3: ATM2 IQ PIC Descriptions
Cables and Connectors
• Duplex SC connector (Rx and Tx)
• SONET/SDHOC12/STM4 fixed transceivers:
• Multimode
• Intermediate reach (IR-1)
Optical interface specifications—see “SONET/SDHOC12/STM4 Optical Interface
Specifications” on page 55
LEDs
Table 66: ATM2OC12/STM4 IQ PIC LEDs
DescriptionStateColorLabel
Not enabledOff—STATUS
Online with no alarms or failuresOn steadilyGreen
Online with alarms for remote failuresOn steadilyYellow
Active with a local alarm; router hasdetected a failure
On steadilyRed
Alarms, Errors, and Events
• Alarm indication signal—line (AIS-L)
• Alarm indication signal—path (AIS-P)
• Bit error rate—signal degrade (BERR-SD)
• Bit error rate—signal fail (BERR-SF)
• Loss of cell delineation (LOC)
• Loss of frame (LOF)
• Loss of pointer (LOP-P)
• Loss of signal (LOS)
• Payloadmismatch (PLM-P)
• Payload unequipped (unequipped STS at path level) (UNEQ-P)
• Remote defect indication—line (RDI-L)
• Remote defect indication—path (RDI-P)
• Error detection:
• Bit interleaved parity errors B1, B2, B3
• Errored seconds (ES-S, ES-L, ES-P)
Copyright © 2017, Juniper Networks, Inc.70
T4000 Core Router Interface Module Reference
• Far-endbit errors, remoteerror indication—line (REI-L), far-end line coding violations
(CV-LFE)
• Far-end bit errors, remote error indication—path (REI-P), far-end path coding
violations (CV-PFE)
• Far-end errored seconds (ES-LFE, ES-PFE)
• Far-end severely errored seconds (SES-LFE, SES-PFE)
• Far-end unavailable seconds (UAS-LFE, UAS-PFE)
• Severely errored framing (SEF)
• Severely errored framing seconds (SEFS-S)
• Severely errored seconds (SES-S, SES-L, SES-P)
• Unavailable seconds (UAS-L, UAS-P)
RelatedDocumentation
• T4000 PIC Description
• T4000 PICs Supported on page 3
71Copyright © 2017, Juniper Networks, Inc.
Chapter 3: ATM2 IQ PIC Descriptions
Copyright © 2017, Juniper Networks, Inc.72
T4000 Core Router Interface Module Reference
CHAPTER 4
Channelized PIC Descriptions
• Channelized DS3 IQ PIC (T4000 Router) on page 73
• Channelized STM1 IQ PIC (T4000 Router) on page 76
• Channelized OC3 IQ PIC (T4000 Router) on page 78
Channelized DS3 IQ PIC (T4000 Router)
• Software Release on page 73
• Hardware Features on page 74
• Software Features on page 74
• Cables and Connectors on page 74
• LEDs on page 75
• Alarms, Errors, and Events on page 75
• Instrumentation (counters) on page 75
Software Release
Junos OS Release 12.1R2 and later (Type 1)
For information on which FPCs support this PIC, see “T4000 PIC/FPC Compatibility” on
page 8.
73Copyright © 2017, Juniper Networks, Inc.
Hardware Features
• Four DS3 ports
• Power requirement: 0.32 A@ 48 V (15.6W)
• Fine-grained queuing per logical interface
• Channelization: DS3, DS0
• Model number: PB-4CHDS3-QPP
• Data service unit (DSU) functionality
• Subrate and scrambling:
• Digital Link/Quick Eagle
• Kentrox
• Larscom
• ADTRAN
• Verilink
• B3ZS line encoding
• M13 or C-bit parity
• Full bit error rate test (BERT)
• Local and remote loopback testing
Software Features
Table 67: Software Features Supported
T4000FirstSupported JunosOSReleaseSoftware Feature
12.1R2Quality of service (QoS) per channel: weighted round-robin (WRR), random earlydetection (RED), weighted random early detection (WRED)
12.1R2Simple Network Management Protocol (SNMP): DS1 MIB, DS3 MIB
12.1R2Dynamic, arbitrary channel configuration
12.1R2Encapsulations:
• Circuit cross-connect (CCC)
• Frame Relay
• High-Level Data Link Control (HDLC)
• Point-to-Point Protocol (PPP)
Cables and Connectors
Standard DS3 BNC coaxial cable interfaces
Copyright © 2017, Juniper Networks, Inc.74
T4000 Core Router Interface Module Reference
LEDs
Table 68: Channelized DS3 IQ PIC LEDs
DescriptionStateColorLabel
Not enabledOff—STATUS
Online with no alarms or failuresOn steadilyGreen
Online with alarms for remote failuresOn steadilyYellow
Active with a local alarm; router hasdetected a failure
On steadilyRed
Alarms, Errors, and Events
• Alarm indication signal (AIS)
• Excessive zeros (EXZ)
• Far-end block error (FEBE)
• Frame error
• Idle code, Idle received
• Line code violation (LCV)
• Loss of signal (LOS)
• Out of frame (OOF)
• Parity bit (P-bit) disagreements
• Path parity error
• Yellow alarm bit (X-bit) disagreements
Instrumentation (counters)
Layer 2 per-queue and per-channel packet and byte counters
RelatedDocumentation
T4000 PIC Description•
• T4000 PICs Supported on page 3
75Copyright © 2017, Juniper Networks, Inc.
Chapter 4: Channelized PIC Descriptions
Channelized STM1 IQ PIC (T4000 Router)
• Junos OS Release 12.1R2 and later (Type 1)
For informationonwhichFPCs support thisPIC, see “T4000PIC/FPCCompatibility” onpage8.
Software release
• One STM1 port
• Power requirement: 0.39 A@ 48 V (18.6W)
• Fine-grained queuing per logical interface
• Channelization: STM1c, fractional E1, framed and unframed DS0
• Model number: PB-1CHSTM1-SMIR-QPP
Description
• Packet buffering, Layer 2 parsing
• Local and remote loopback testing
Hardware features
• Quality of service (QoS) per channel: weighted round-robin (WRR), random early detection(RED), weighted random early detection (WRED)
• SNMP: SONET/SDHMIB, T1/E1 MIB
• Dynamic, arbitrary channel configuration
• Full bit error rate test (BERT) patterns at E1 and DS0 levels
• Encapsulations:
• High-Level Data Link Control (HDLC)
• Frame Relay
• Circuit cross-connect (CCC)
• Translational cross-connect (TCC)
• Point-to-Point Protocol (PPP)
Software features
• Duplex SC/PC connector (Rx and Tx)
• Single-mode fiber
• Intermediate-reach fixed transceiver
• Optical interface specifications—see “SONET/SDHOC3/STM1Optical InterfaceSpecifications”on page 53
NOTE: This PIC supports only SDH.
Cables and connectors
Copyright © 2017, Juniper Networks, Inc.76
T4000 Core Router Interface Module Reference
One tricolor per port:
• Off—Not enabled
• Green—Online with no alarms or failures
• Yellow—Online with alarms for remote failures
• Red—Active with a local alarm; router has detected a failure
LEDs
• Alarm indication signal—line (AIS-L)
• Alarm indication signal—path (AIS-P)
• Bit error rate—signal degrade (BERR-SD)
• Bit error rate—signal fail (BERR-SF)
• Bit interleaved parity errors B1, B2, B3 (CV-S, CV-L, CV-P)
• Loss of frame (LOF)
• Loss of pointer (LOP-P)
• Loss of signal (LOS)
• Payloadmismatch (PLM-P)
• Payload unequipped (unequipped STS at path level) (UNEQ-P)
• Remote defect indication—line (RDI-L)
• Remote defect indication—path (RDI-P)
Error detection:
• Errored seconds (ES-S, ES-L, ES-P)
• Far-endbit errors, remote error indication—line (REI-L), far-end line coding violations (CV-LFE)
• Far-endbiterrors, remoteerror indication—path(REI-P), far-endpathcodingviolations(CV-PFE)
• Far-end errored seconds (ES-LFE, ES-PFE)
• Far-end severely errored seconds (SES-LFE, SES-PFE)
• Far-end unavailable seconds (UAS-LFE, UAS-PFE)
• Severely errored framing (SEF)
• Severely errored framing seconds (SEFS-S)
• Severely errored seconds (SES-S, SES-L, SES-P)
• Unavailable seconds (UAS-L, UAS-P)
Alarms, errors, andevents
• Layer 2 per-queue and per-channel packet and byte countersInstrumentation(counters)
RelatedDocumentation
T4000 PIC Description•
• T4000 PICs Supported on page 3
77Copyright © 2017, Juniper Networks, Inc.
Chapter 4: Channelized PIC Descriptions
Channelized OC3 IQ PIC (T4000 Router)
• Junos OS Release 12.1R2 and later (Type 1)
For informationonwhichFPCs support thisPIC, see “T4000PIC/FPCCompatibility” onpage8.
Software release
• One OC3 port
• Power requirement: 0.39 A@ 48 V (18.6W)
• Fine-grained queuing per logical interface
• Channelization: DS3, DS1, DS0
• Model number: PB-1CHOC3-SMIR-QPP
Description
• Subrate and scrambling:
• Digital Link/Quick Eagle
• Kentrox
• Larscom
• ADTRAN
• Verilink
• Packet buffering, Layer 2 parsing
• M13/C-bit parity encoding
• DS3 far-end alarm and control (FEAC) channel support
• Local and remote loopback testing
Hardware features
Copyright © 2017, Juniper Networks, Inc.78
T4000 Core Router Interface Module Reference
• Quality of service (QoS) per channel: weighted round-robin (WRR), random early detection(RED), weighted random early detection (WRED)
• Simple Network Management Protocol (SNMP): OC3 MIB, DS3 MIB, T1 MIB
• Dynamic, arbitrary channel configuration
• Full bit error rate test (BERT)
• Encapsulations:
• Circuit cross-connect (CCC)
• Translational cross-connect (TCC)
• Frame Relay
• High-Level Data Link Control (HDLC)
• Point-to-Point Protocol (PPP)
Software features
• Duplex SC/PC connector (Rx and Tx)
• Single-mode fiber SONET/SDHOC3/STM1 intermediate-reach (IR-1) fiber
• Optical interface specifications—see “SONET/SDHOC3/STM1Optical InterfaceSpecifications”on page 53
Cables and connectors
One tricolor per port:
• Off—Not enabled
• Green—Online with no alarms or failures
• Yellow—Online with alarms for remote failures
• Red—Active with a local alarm; router has detected a failure
LEDs
• Alarm indication signal (AIS-L, AIS-P)
• Bit error rate signal degrade (BERR-SD), bit error rate signal fail (BERR-SF)
• Bit interleaved parity errors B1, B2, B3
• Errored seconds (ES-S, ES-L, ES-P), far-end bit errors REI-L, REI-P (CV-LFE, CV-PFE), Far-endblockerror (FEBE), far-enderroredseconds (ES-LFE, ES-PFE), far-endseverely erroredseconds(SES-LFE, SES-PFE), far-end unavailable seconds (UAS-LFE, UAS-PFE)
• Frame error
• Idle code, Idle received
• Loss of frame (LOF), loss of pointer (LOP-P), loss of signal (LOS)
• Out of frame (OOF)
• Payloadmismatch (PLM-P), payload unequipped (UNEQ-P)
• Parity bit (P-bit) disagreements
• Path parity error
• Remote defect indication (RDI-L, RDI-P)
• Severely errored framing (SEF), severely errored framing seconds (SEFS-S), severely erroredseconds (SES-S, SES-L, SES-P), unavailable seconds (UAS-L, UAS-P)
• Yellow alarm bit (X-bit) disagreements
Alarms, errors, andevents
RelatedDocumentation
• T4000 PIC Description
• T4000 PICs Supported on page 3
79Copyright © 2017, Juniper Networks, Inc.
Chapter 4: Channelized PIC Descriptions
Copyright © 2017, Juniper Networks, Inc.80
T4000 Core Router Interface Module Reference
CHAPTER 5
Channelized Enhanced IQ (IQE) PICDescriptions
• Channelized DS3/E3 Enhanced IQ (IQE) PIC (T4000 Router) on page 82
• Channelized E1/T1 Enhanced IQ (IQE) PIC (T4000 Router) on page 85
• Channelized OC3/STM1 Enhanced IQ (IQE) PICwith SFP (T4000 Router) on page 88
• ChannelizedOC12/STM4Enhanced IQ(IQE)PICswithSFP(T4000Router)onpage92
• ChannelizedOC48/STM16Enhanced IQ(IQE)PICwithSFP(T4000Router)onpage99
81Copyright © 2017, Juniper Networks, Inc.
Channelized DS3/E3 Enhanced IQ (IQE) PIC (T4000 Router)
g002
620
• Junos OS Release 12.1R2 and later (Type 1)
For informationonwhichFPCs support thisPIC, see “T4000PIC/FPCCompatibility” onpage8.
Software release
• Four E3 or Channelized DS3 ports
• E3 or Channelized DS3 is configurable on a per-port granularity
• DS3 channelization:
• 4 DS3 channels
• 112 DS1 channels
• 1011 DS0 channels
• Power requirement: 0.53 A@ 48 V (25.4W)
• Model number: PB-4CHDS3-E3-IQE-BNC
Description
• Ports are numbered 0 through 3 top to bottomHardware features
Copyright © 2017, Juniper Networks, Inc.82
T4000 Core Router Interface Module Reference
• Maximum transmission units (MTUs) of up to 9000 bytes
• Dynamic, arbitrary channel configuration
• Subrate and scrambling:
NOTE: Only DS3 interfaces supports subrate and scrambling.
• Digital Link/Quick Eagle
• Kentrox
• Larscom
• ADTRAN
• Verilink (subrate: only port Amode)
NOTE: For DS3 interfaces, Verilink does not function if an IQE interface is paired with an IQinterface.
• Data service unit (DSU) functionality
• B3ZS line encoding
• Framing: M13, C-bit parity, framed clear channel
• Full bit error rate test (BERT) for DS0, DS1, and DS3
• ANSI T1.403 FDL
• Internal and loop clocking for DS3 and DS1
• DS3 far end alarm and control (FEAC) channel
• Local line, remote line, and remote playback loopback testing for each DS3 and DS1 channels
• Quality of service (QoS) per channel: weighted round-robin (WRR), random early detection(RED), weighted random early detection (WRED)
• Enhanced fine-grained queuing per logical interface. See the Class of Service Feature Guide forRouting Devices for more information about class of service features.
• Simple Network Management Protocol (SNMP): DS1 MIB, DS3 MIB
• Encapsulations:
• Circuit cross-connect (CCC)
• Translational cross-connect (TCC)
• Extended Frame Relay for CCC and TCC
• Flexible Frame Relay
• Frame Relay
• Frame Relay for CCC
• Frame Relay for TCC
• Frame Relay port CCC
• High-Level Data Link Control (HDLC)
• HDLC framing for CCC
• HDLC framing for TCC
• MPLS CCC
• MPLS TCC
• Multilink Frame Relay (MLFR) UNI NNI (MFR FRF.16)
• Point-to-Point Protocol (PPP)
• PPP for CCC
• PPP for TCC
Software features
• Standard DS3 BNC coaxial cable interfacesCables and connectors
83Copyright © 2017, Juniper Networks, Inc.
Chapter 5: Channelized Enhanced IQ (IQE) PIC Descriptions
One tricolor per port:
• Off—Not enabled
• Green—Online with no alarms or failures
• Yellow—Online with alarms for remote failures
• Red—Active with a local alarm; router has detected a failure
LEDs
• Alarm reporting for error statistics and failure counts
• DS1 alarms:
• Alarm indication signal (AIS)
• Loss of frame (LOF)
• Remote alarm indication signal (RAIS)
• DS1 error detection:
• Bursty errored seconds (BES)
• CRC errors
• Errored seconds (ES)
• Line errored seconds (LES)
• Loss of framing seconds (LOFS)
• Loss of signal seconds (LOSS)
• Severely errored seconds (SES)
• Severely errored framing seconds (SEFS)
• Unavailable seconds (UAS)
• DS3 alarms:
• Alarm indication signal (AIS)
• Loss of frame (LOF)
• Loss of signal (LOS)
• Phase lock loop (PLL)
• DS3 error detection:
• C-bit code violations (CCV)
• C-bit errored seconds (CES)
• C-bit severely errored framing seconds (CEFS)
• CRC errors
• Excessive zeros (EXZ)
• Far-end block error (FEBE)
• Far-end receive failure (FERF)
• Line errored seconds (LES)
• Parity bit (P-bit) code violations (PCV)
• Parity bit (P-bit) errored seconds (PES)
• Parity bit (P-bit) severely errored framing seconds (PSES)
• Severely errored framing seconds (SEFS)
• Unavailable seconds (UAS)
Alarms, errors, andevents
• Layer 2 per-queue and per-channel packet and byte countersInstrumentation(counters)
Copyright © 2017, Juniper Networks, Inc.84
T4000 Core Router Interface Module Reference
RelatedDocumentation
T4000 PIC Description•
• T4000 PICs Supported on page 3
Channelized E1/T1 Enhanced IQ (IQE) PIC (T4000 Router)
g004
432
• Junos OS Release12.1R2 and later (Type 1)
For informationonwhichFPCs support thisPIC, see “T4000PIC/FPCCompatibility” onpage8.
Software release
• Ten E1 or T1 ports
• DS1 and E1 interfaces are selectable on a per-port granularity
• E1 channelization per PIC:
• 10 E1 channels
• 310 DS0 channels
• T1 channelization per PIC:
• 10 T1 channels
• 240 DS0 channels
• Power requirement: 0.52 A@ 48 V (24.73W)
• Model number: PB-10CHE1-T1-IQE-RJ48
Description
Ports are numbered:
• Top row: 0 and 1 from left to right
• Second row: 2 and 3 from left to right
• Third row: 3 and 4 from left to right
• Bottom row: 5 and 6 from left to right
Hardware features
Software features • Quality of service (QoS) per channel: weighted round-robin (WRR), random early detection(RED), weighted random early detection (WRED)
85Copyright © 2017, Juniper Networks, Inc.
Chapter 5: Channelized Enhanced IQ (IQE) PIC Descriptions
• Enhanced fine-grained queuing per logical interface. See the Class of Service Feature Guide forRouting Devices for more information about class of service features.
• Support sending and receiving in-band loopback codes in both framed and unframedmode:
• Framed in-band loopback at CSU
• Framed in-band loopback at Smartjack (ANSI)
• Unframed in-band loopback at CSU
• Unframed in-band loopback at Smartjack (ANSI)
• You can configure the following framingmodes using the CLI:
• T1—SF (D4/superframe), ESF (extended superframe)
• E1—G704, G704–no-crc4, unframed
• Packet buffering, Layer 2 parsing
• Local line, remote line, and remote payload loopback testing; each channel can be loopedindividually and independently of other channels (DS1/E1 channels)
• Simple Network Management Protocol (SNMP): T1 MIB (RFC 1406)
• Dynamic, arbitrary channel configuration
• Full bit error rate test (BERT)
• Clocking: internal and loop (clock recovered fromnetwork anduse for transmit). Internal timingis the default for channelized T1 ports. The external master clock can be amultiple of 2.048MHz or 1.544 MHz for E1 or T1 operation.
• Line coding:
• T1—CLI configurable as AMI or B8ZS
• E1—HDB3
• Encapsulations:
• Circuit cross-connect (CCC)
• Translational cross-connect (TCC)
• Extended Frame Relay for CCC and TCC
• Flexible Frame Relay
• Frame Relay
• Frame Relay for CCC
• Frame Relay for TCC
• Frame Relay port CCC
• High-Level Data Link Control (HDLC)
• HDLC framing for CCC
• HDLC framing for TCC
• MPLS CCC
• MPLS TCC
• Point-to-Point Protocol (PPP)
• PPP for CCC
• PPP for TCC
• Encapsulations available only for DS0 and DS1:
• Multilink Frame Relay end-to-end (MLFR FRF.15)
• Multilink Frame Relay (MLFR) UNI NNI (MFR FRF.16)
• Multilink PPP (MLPPP)
• Encapsulations available only for DS1:
• PPP over Frame Relay
Copyright © 2017, Juniper Networks, Inc.86
T4000 Core Router Interface Module Reference
• 120-ohm RJ-48C connector (female)Cables and connectors
One tricolor per port:
• Off—Not enabled
• Green—Online with no alarms or failures
• Yellow—Online with alarms for remote failures
• Red—Active with a local alarm; router has detected a failure
LEDs
• DS1 alarms:
• Alarm indication signal (AIS)
• Loss of frame (LOF)
• Remote alarm indication signal (RAIS)
• 24-hour alarm reporting history maintained for error statistics and failure counts, 15-minuteintervals on all errors
• DS1 error detection:
• Bursty errored seconds (BES)
• CRC errors
• Errored seconds (ES)
• Line errored seconds (LES)
• Loss of framing seconds (LOFS)
• Loss of signal seconds (LOSS)
• Severely errored seconds (SES)
• Severely errored framing seconds (SEFS)
• Unavailable seconds (UAS)
Alarms, errors, andevents
• Layer 2 per-queue and per-channel packet and byte counters
• Layer 2 per-queue and per-channel packet and byte drop counters
Instrumentation(counters)
RelatedDocumentation
T4000 PIC Description•
• T4000 PICs Supported on page 3
87Copyright © 2017, Juniper Networks, Inc.
Chapter 5: Channelized Enhanced IQ (IQE) PIC Descriptions
Channelized OC3/STM1 Enhanced IQ (IQE) PICwith SFP (T4000 Router)
• Junos OS Release 12.1R2 and later (Type 1)
For informationonwhichFPCs support thisPIC, see “T4000PIC/FPCCompatibility” onpage8.
Software release
• Two OC3 or STM1 ports
• SONET or SDH is configurable on a per-port granularity
• SONET channelization:
• 2 OC3 channels
• 6 DS3 channels
• 168 DS1 channels
• 1011 DS0 channels
• SDH channelization:
• 2 STM1 channels (non-concatenated)
• 6 E3 channels
• 126 E1 channels
• 6 DS3 channels (Junos OS Release 10.1 and later)
• 168 DS1 channels (Junos OS Release 10.1 and later)
• 1011 DS0 channels
• Power requirement: 0.56 A@ 48 V (27.1 W)
• Model number: PB-2CHOC3-STM1-IQE-SFP
Description
• Ports are numbered 0 and 1 from left to rightHardware features
Software features • Dynamic, arbitrary channel configuration
• Quality of service (QoS) per channel: weighted round-robin (WRR), random early detection(RED), weighted random early detection (WRED)
• Enhanced fine-grained queuing per logical interface. See the Class of Service Feature Guide forRouting Devices for more information about class of service features.
Copyright © 2017, Juniper Networks, Inc.88
T4000 Core Router Interface Module Reference
• Subrate and scrambling:
• Digital Link/Quick Eagle
• Kentrox
• Larscom
• ADTRAN
• Verilink
• Packet buffering, Layer 2 parsing
• M13/C-bit parity encoding
• DS3 far-end alarm and control (FEAC) channel support
• Local line, remote line, and remote payload loopback testing
• Simple Network Management Protocol (SNMP): OC3 MIB, DS3 MIB, T1 MIB
• Full bit error rate test (BERT)
• Encapsulations:
• Circuit cross-connect (CCC)
• Translational cross-connect (TCC)
• Extended Frame Relay for CCC and TCC
• Flexible Frame Relay
• Frame Relay
• Frame Relay for CCC
• Frame Relay for TCC
• Frame Relay port CCC
• High-Level Data Link Control (HDLC)
• HDLC framing for CCC
• HDLC framing for TCC
• MPLS CCC
• MPLS TCC
• Multilink Frame Relay (MLFR) UNI NNI (MFR FRF.16)
• Point-to-Point Protocol (PPP)
• PPP for CCC
• PPP for TCC
• Encapsulations available only for DS1:
• Multilink Frame Relay end-to-end (MLFR FRF.15)
• Multilink PPP (MLPPP)
• PPP over Frame Relay
• Duplex LC/PC connector (Rx and Tx)
• SONET/SDHOC3/STM1 fiber-optic SFPs:
• Multimode (model number: SFP-OC3-SR)
• Intermediate reach (IR-1) (model number: SFP-OC3-IR)
• Long reach (IR-1) (model number: SFP-OC3-LR)
Optical interface specifications—see “SONET/SDHOC3/STM1Optical InterfaceSpecifications”on page 53
Cables and connectors
89Copyright © 2017, Juniper Networks, Inc.
Chapter 5: Channelized Enhanced IQ (IQE) PIC Descriptions
One tricolor Status LED per port:
• Off—Not enabled.
• Green—Online with no alarms or failures.
• Yellow—Online with alarms for remote failures.
• Red—Active with a local alarm; router has detected a failure.
LEDs
Alarms, errors, andevents
• SONET alarms:
• Alarm indication signal—line (AIS-L)
• Alarm indication signal—path (AIS-P)
• Bit error rate—signal degrade (BERR-SD)
• Bit error rate—signal fail (BERR-SF)
• Loss of clock (LOC)
• Loss of frame (LOF)
• Loss of light (LOL)
• Loss of pointer (LOP)
• Loss of signal (LOS)
• Payload label mismatch (PLM-P)
• Remote defect indication—line (RDI-L)
• Remote defect indication—path (RDI-P)
• Remote error indication (REI)
• Payload unequipped (unequipped STS at path level) (UNEQ-P)
• Virtual container—alarm indication signal (VAIS)
• Virtual container—loss of clock (VLOC)
• Virtual container—loss of pointer (VLOP)
• Virtual container—mismatch (VMIS)
• Virtual container—remote defect indication (VRD1)
• Virtual container—unequipped (VUNEQ)
• SDH alarms:
• Administrative unit alarm indication signal (AU-AIS)
• Bit error rate signal degrade (BERR-SD)
• Bit error rate signal fail (BERR-SF)
• Bit interleaved parity (BIP) error B1, B2, B3
• Higher order path—alarm indication signal (HP-AIS)
• Higher order path—far-end receive failure (HP-FERF)
• Higher order path—payload label mismatch (HP-PLM)
• Higher order path—loss of pointer (HP-LOP)
• Higher order path—remote defect indication (HP-RDI)
• Higher order path—unequipped (HP-UNEQ)
• Loss of clock (LOC)
• Loss of frame (LOF)
• Loss of light (LOL)
• Loss of signal (LOS)
• Multiplex section—alarm indication signal (MS-AIS)
• Multiplex section—far-end receive failure (MS-FERF)
• Multiplex section—remote defect indication (MS-RDI)
• Multiplex section—remote error indication (MS-REI)
Copyright © 2017, Juniper Networks, Inc.90
T4000 Core Router Interface Module Reference
• Phase lock loop (PLL)
• Remote error indication (REI)
• Severely errored frame (SEF)
• Tributary unit—alarm indication signal (TU-AIS)
• Tributary unit—loss of clock (TU-LOC)
• Tributary unit—loss of pointer (TU-LOP)
• Tributary unit—mismatch (TU-MIS)
• Tributary unit—remote defect indication (TU-RD1)
• Tributary unit—unequipped (TU-UNEQ)
• DS1 alarms:
• Alarm indication signal (AIS)
• Loss of frame (LOF)
• Remote alarm indication signal (RAIS)
• DS1 error detection:
• Bursty errored seconds (BES)
• CRC errors
• Errored seconds (ES)
• Line errored seconds (LES)
• Loss of framing seconds (LOFS)
• Loss of signal seconds (LOSS)
• Severely errored seconds (SES)
• Severely errored framing seconds (SEFS)
• Unavailable seconds (UAS)
• DS3 alarms:
• Alarm indication signal (AIS)
• Loss of frame (LOF)
• Loss of signal (LOS)
• Phase lock loop (PLL)
• DS3 error detection:
• C-bit code violations (CCV)
• C-bit errored seconds (CES)
• C-bit severely errored framing seconds (CEFS)
• CRC errors
• Excessive zeros (EXZ)
• Far-end block error (FEBE)
• Far-end receive failure (FERF)
• Line errored seconds (LES)
• Parity bit (P-bit) code violations (PCV)
• Parity bit (P-bit) errored seconds (PES)
• Parity bit (P-bit) severely errored framing seconds (PSES)
• Severely errored framing seconds (SEFS)
• Unavailable seconds (UAS)
91Copyright © 2017, Juniper Networks, Inc.
Chapter 5: Channelized Enhanced IQ (IQE) PIC Descriptions
RelatedDocumentation
T4000 PIC Description•
• T4000 PICs Supported on page 3
Channelized OC12/STM4 Enhanced IQ (IQE) PICs with SFP (T4000 Router)
Figure 3: 4-Port IQE PIC (Type 2)
g004
426
Figure 2: 1-Port IQE PIC
Figure 4: 4-Port IQE PIC (Type 3)
g002
706
• Software Release on page 93
• Hardware Features on page 93
• Software Features on page 94
• Cables and Connectors on page 95
Copyright © 2017, Juniper Networks, Inc.92
T4000 Core Router Interface Module Reference
• LEDs on page 96
• Alarms, Errors, and Events on page 96
• Instrumentation (counters) on page 98
Software Release
• Junos OS Release 12.1R2 (Type 1)
• Junos OS Release 12.2R2 (Type 2)
• Junos OS Release 13.2 (Type 3)
For information on which FPCs support these PICs, see“T4000 PIC/FPC Compatibility”
on page 8.
Hardware Features
• Four OC12/STM4 ports
• SONET or SDH is configurable on a per-port granularity
• SONET channelization (4-port PIC):
• 4 OC12 channel
• 16 OC3 channels
• 48 DS3 channels
• 672 DS1 channels
• 974 DS0 channels
• SDH channelization (4-port PIC):
• 4 STM4 channel
• 16 STM1 channels
• 48 E3 channels
• 504 E1 channels
• 48 DS3 channels
• 672 DS1 channels
• 974 DS0 channels
• Power requirement: 1.08 A@–48V (52W)
• Model number (Type 1): PB-1CHOC12-STM4-IQE-SFP
• Model number (Type 2): PB-4CHOC12-STM4-IQE-SFP
• Model number (Type 3): PC-4CHOC12-STM4-IQE-SFP
• 1-port: Port is numbered 0.
• 4-port: Ports are numbered:
• Top row: 2 and 0 from left to right
93Copyright © 2017, Juniper Networks, Inc.
Chapter 5: Channelized Enhanced IQ (IQE) PIC Descriptions
• Bottom row: 3 and 1 from left to right
Software Features
Table 69: Software Features Supported
T4000 First SupportedJunos OS ReleaseSoftware Feature
12.1R2Quality of service (QoS) per channel: weighted round-robin (WRR), random early detection(RED), weighted random early detection (WRED)
12.1R2Enhanced fine-grained queuing per logical interface. See the Junos OS Class of Service Libraryfor Routing Devices for more information about class of service features.
12.1R2Subrate and scrambling:
• Digital Link/Quick Eagle
• Kentrox
• Larscom
• ADTRAN
• Verilink
12.1R2Packet buffering, Layer 2 parsing
12.1R2M13/C-bit parity encoding
12.1R2DS3 far-end alarm and control (FEAC) channel support
12.1R2Local line, remote line, and remote payload loopback testing
12.1R2Simple Network Management Protocol (SNMP): OC3 MIB, DS3 MIB, T1 MIB
12.1R2Dynamic, arbitrary channel configuration
12.1R2Full bit error rate test (BERT)
Copyright © 2017, Juniper Networks, Inc.94
T4000 Core Router Interface Module Reference
Table 69: Software Features Supported (continued)
T4000 First SupportedJunos OS ReleaseSoftware Feature
12.1R2Encapsulations:
• Circuit cross-connect (CCC)
• Translational cross-connect (TCC)
• Extended Frame Relay for CCC and TCC
• Flexible Frame Relay
• Frame Relay
• Frame Relay for CCC
• Frame Relay for TCC
• Frame Relay port CCC
• High-Level Data Link Control (HDLC)
• HDLC framing for CCC
• HDLC framing for TCC
• MPLS CCC
• MPLS TCC
12.1R2• Multilink Frame Relay (MLFR) UNI NNI (MFR FRF.16)
• Point-to-Point Protocol (PPP)
• PPP for CCC
• PPP for TCC
12.1R2Encapsulations available only for DS1:
• Multilink Frame Relay end-to-end (MLFR FRF.15)
• Multilink PPP (MLPPP)
• PPP over Frame Relay
Cables and Connectors
• Duplex LC connector (Rx and Tx); single-mode fiber
• SONET/SDHOC12/STM4 fiber-optic SFP transceivers:
• Short reach (model number: SFP-OC12-SR)
• Intermediate reach (IR-1) (model number: SFP-OC12-IR)
• Long reach (LR-1) (model number: SFP-OC12-LR)
Optical interface specifications—see “SONET/SDHOC12/STM4 Optical Interface
Specifications” on page 55
95Copyright © 2017, Juniper Networks, Inc.
Chapter 5: Channelized Enhanced IQ (IQE) PIC Descriptions
LEDs
Table 70: Channelized OC12/STM4 Enhanced IQ (IQE) PICs with SFP LEDs
DescriptionStateColorLabel
Not enabledOff—STATUS
Online with no alarms or failuresOn steadilyGreen
Online with alarms for remote failuresOn steadilyYellow
Active with a local alarm; router has detected a failureOn steadilyRed
Alarms, Errors, and Events
• SONET alarms:
• Alarm indication signal—line (AIS-L)
• Alarm indication signal—path (AIS-P)
• Bit error rate—signal degrade (BERR-SD)
• Bit error rate—signal fail (BERR-SF)
• Loss of frame (LOF)
• Loss of light (LOL)
• Loss of pointer (LOP)
• Loss of signal (LOS)
• Payload label mismatch (PLM-P)
• Remote defect indication—line (RDI-L)
• Remote defect indication—path (RDI-P)
• Remote error indication (REI)
• Payload unequipped (unequipped STS at path level) (UNEQ-P)
• Virtual container—alarm indication signal (VAIS)
• Virtual container—loss of pointer (VLOP)
• Virtual container—mismatch (VMIS)
• Virtual container—remote defect indication (VRD1)
• Virtual container—unequipped (VUNEQ)
• SDH alarms:
• Administrative unit alarm indication signal (AU-AIS)
• Bit error rate—signal degrade (BERR-SD)
Copyright © 2017, Juniper Networks, Inc.96
T4000 Core Router Interface Module Reference
• Bit error rate—signal fail (BERR-SF)
• Bit interleaved parity (BIP) error B1, B2, B3
• Higher order path—alarm indication signal (HP-AIS)
• Higher order path—far-end receive failure (HP-FERF)
• Higher order path—payload label mismatch (HP-PLM)
• Higher order path—loss of pointer (HP-LOP)
• Higher order path—remote defect indication (HP-RDI)
• Higher order path—unequipped (HP-UNEQ)
• Loss of frame (LOF)
• Loss of light (LOL)
• Loss of signal (LOS)
• Multiplex section—alarm indication signal (MS-AIS)
• Multiplex section—far-end receive failure (MS-FERF)
• Multiplex section—remote defect indication (MS-RDI)
• Multiplex section—remote error indication (MS-REI)
• Phase lock loop (PLL)
• Remote error indication (REI)
• Severely errored frame (SEF)
• Tributary unit—alarm indication signal (TU-AIS)
• Tributary unit—loss of pointer (TU-LOP)
• Tributary unit—mismatch (TU-MIS)
• Tributary unit—remote defect indication (TU-RD1)
• Tributary unit—unequipped (TU-UNEQ)
• DS1 alarms:
• Alarm indication signal (AIS)
• Loss of frame (LOF)
• Remote alarm indication signal (RAIS)
• DS1 error detection:
• Bursty errored seconds (BES)
• CRC errors
• Errored seconds (ES)
• Line errored seconds (LES)
• Loss of framing seconds (LOFS)
97Copyright © 2017, Juniper Networks, Inc.
Chapter 5: Channelized Enhanced IQ (IQE) PIC Descriptions
• Severely errored seconds (SES)
• Severely errored framing seconds (SEFS)
• Unavailable seconds (UAS)
• DS3 alarms:
• Alarm indication signal (AIS)
• Loss of frame (LOF)
• Yellow alarm
• DS3 error detection:
• C-bit code violations (CCV)
• C-bit errored seconds (CES)
• C-bit severely errored framing seconds (CEFS)
• CRC errors
• Excessive zeros (EXZ)
• Far-end block error (FEBE)
• Far-end receive failure (FERF)
• Line errored seconds (LES)
• Parity bit (P-bit) code violations (PCV)
• Parity bit (P-bit) errored seconds (PES)
• Parity bit (P-bit) severely errored framing seconds (PSES)
• Severely errored framing seconds (SEFS)
• Unavailable seconds (UAS)
Instrumentation (counters)
Layer 2 per-queue and per-channel packet and byte counters
RelatedDocumentation
T4000 PIC Description•
• T4000 PICs Supported on page 3
Copyright © 2017, Juniper Networks, Inc.98
T4000 Core Router Interface Module Reference
Channelized OC48/STM16 Enhanced IQ (IQE) PICwith SFP (T4000 Router)
• Software Release on page 99
• Hardware Features on page 99
• Software Features on page 100
• Cables and Connectors on page 101
• LEDs on page 102
• Alarms, Errors, and Events on page 102
• Instrumentation (counters) on page 104
• PICs Supported in the Fourth Slot of T640-FPC2-E and T640-FPC2-E2 with Type 2
IQE PICs on page 105
Software Release
Junos OS Release 12.2R2 and later (Type 2)
For information on which FPCs support this PIC, see “T4000 PIC/FPC Compatibility” on
page 8.
Hardware Features
• One OC48/STM16 port
• SONET or SDH is configurable on a per-port granularity
• SONET channelization:
• 4 OC12 channels
• 16 OC3 channels
• 48 DS3 channels
99Copyright © 2017, Juniper Networks, Inc.
Chapter 5: Channelized Enhanced IQ (IQE) PIC Descriptions
• 672 DS1 channels
• 975 DS0 channels
• SDH channelization:
• 4 STM4 channels
• 16 STM1 channels
• 48 E3 channels
• 504 E1 channels
• 48 DS3 channels
• 672 DS1 channels
• 975 DS0 channels
• Power requirement: 1.10 A@ 48V (53W)
• Model number: PB-1CHOC48-STM16-IQE-SFP
• Port is numbered 0.
Software Features
Table 71: Software Features Supported
T4000 First SupportedJunos OS ReleaseSoftware Feature
12.2R2Quality of service (QoS) per channel: weighted round-robin (WRR), random early detection(RED), weighted random early detection (WRED)
12.1R2Enhanced fine-grained queuing per logical interface. See the Junos OS Class of Service Libraryfor Routing Devices for more information about class of service features.
12.2R2Subrate and scrambling:
• Digital Link/Quick Eagle
• Kentrox
• Larscom
• ADTRAN
• Verilink
12.2R2Packet buffering, Layer 2 parsing
12.2R2M13/C-bit parity encoding
12.2R2DS3 far-end alarm and control (FEAC) channel support
12.2R2Local line, remote line, and remote payload loopback testing
12.2R2Simple Network Management Protocol (SNMP): OC3 MIB, DS3 MIB, T1 MIB
Copyright © 2017, Juniper Networks, Inc.100
T4000 Core Router Interface Module Reference
Table 71: Software Features Supported (continued)
T4000 First SupportedJunos OS ReleaseSoftware Feature
12.2R2Dynamic, arbitrary channel configuration
12.2R2Full bit error rate test (BERT)
12.2R2Encapsulations:
• Circuit cross-connect (CCC)
• Translational cross-connect (TCC)
• Extended Frame Relay for CCC and TCC
• Flexible Frame Relay
• Frame Relay
• Frame Relay for CCC
• Frame Relay for TCC
• Frame Relay port CCC
• High-Level Data Link Control (HDLC)
• HDLC framing for CCC
• HDLC framing for TCC
• MPLS CCC
• MPLS TCC
• Multilink Frame Relay (MLFR) UNI NNI (MFR FRF.16)
• Point-to-Point Protocol (PPP)
• PPP for CCC
• PPP for TCC
12.2R2Encapsulations available only for DS1:
• Multilink Frame Relay end-to-end (MLFR FRF.15)
• Multilink PPP (MLPPP)
• PPP over Frame Relay
Cables and Connectors
• Duplex LC connector (Rx and Tx); single-mode fiber
• SONET/SDHOC48/STM16 fiber-optic SFP transceivers:
• Short reach (SR-1) (model number: SFP-1OC48-SR)
• Intermediate reach (IR-1) (model number: SFP-1OC48-IR)
• Long reach (LR-1) (model number: SFP-1OC48-LR)
Optical interface specifications—see “SONET/SDHOC48/STM16 Optical Interface
Specifications” on page 57
101Copyright © 2017, Juniper Networks, Inc.
Chapter 5: Channelized Enhanced IQ (IQE) PIC Descriptions
LEDs
Table 72: Channelized OC48/STM16 Enhanced IQ (IQE) PICwith SFP LEDs
DescriptionStateColorLabel
Not enabledOff—STATUS
Online with no alarms or failuresOn steadilyGreen
Online with alarms for remote failuresOn steadilyYellow
Active with a local alarm; router has detected a failureOn steadilyRed
Alarms, Errors, and Events
• SONET alarms:
• Alarm indication signal—line (AIS-L)
• Alarm indication signal—path (AIS-P)
• Bit error rate—signal degrade (BERR-SD)
• Bit error rate—signal fail (BERR-SF)
• Loss of frame (LOF)
• Loss of light (LOL)
• Loss of pointer (LOP)
• Loss of signal (LOS)
• Payload label mismatch (PLM-P)
• Remote defect indication—line (RDI-L)
• Remote defect indication—path (RDI-P)
• Remote error indication (REI)
• Payload unequipped (unequipped STS at path level) (UNEQ-P)
• Virtual container—alarm indication signal (VAIS)
• Virtual container—loss of pointer (VLOP)
• Virtual container—mismatch (VMIS)
• Virtual container—remote defect indication (VRD1)
• Virtual container—unequipped (VUNEQ)
• SDH alarms:
• Administrative unit alarm indication signal (AU-AIS)
• Bit error rate—signal degrade (BERR-SD)
Copyright © 2017, Juniper Networks, Inc.102
T4000 Core Router Interface Module Reference
• Bit error rate—signal fail (BERR-SF)
• Bit interleaved parity (BIP) error B1, B2, B3
• Higher order path—alarm indication signal (HP-AIS)
• Higher order path—far-end receive failure (HP-FERF)
• Higher order path—payload label mismatch (HP-PLM)
• Higher order path—loss of pointer (HP-LOP)
• Higher order path—remote defect indication (HP-RDI)
• Higher order path—unequipped (HP-UNEQ)
• Loss of frame (LOF)
• Loss of light (LOL)
• Loss of signal (LOS)
• Multiplex section—alarm indication signal (MS-AIS)
• Multiplex section—far-end receive failure (MS-FERF)
• Multiplex section—remote defect indication (MS-RDI)
• Multiplex section—remote error indication (MS-REI)
• Phase lock loop (PLL)
• Remote error indication (REI)
• Severely errored frame (SEF)
• Tributary unit—alarm indication signal (TU-AIS)
• Tributary unit—loss of pointer (TU-LOP)
• Tributary unit—mismatch (TU-MIS)
• Tributary unit—remote defect indication (TU-RD1)
• Tributary unit—unequipped (TU-UNEQ)
• DS1 alarms:
• Alarm indication signal (AIS)
• Loss of frame (LOF)
• Remote alarm indication signal (RAIS)
• DS1 error detection:
• Bursty errored seconds (BES)
• CRC errors
• Errored seconds (ES)
• Line errored seconds (LES)
• Loss of framing seconds (LOFS)
103Copyright © 2017, Juniper Networks, Inc.
Chapter 5: Channelized Enhanced IQ (IQE) PIC Descriptions
• Severely errored seconds (SES)
• Severely errored framing seconds (SEFS)
• Unavailable seconds (UAS)
• DS3 alarms:
• Alarm indication signal (AIS)
• Loss of frame (LOF)
• Yellow alarm
• DS3 error detection:
• C-bit code violations (CCV)
• C-bit errored seconds (CES)
• C-bit severely errored framing seconds (CEFS)
• CRC errors
• Excessive zeros (EXZ)
• Far-end block error (FEBE)
• Far-end receive failure (FERF)
• Line errored seconds (LES)
• Parity bit (P-bit) code violations (PCV)
• Parity bit (P-bit) errored seconds (PES)
• Parity bit (P-bit) severely errored framing seconds (PSES)
• Severely errored framing seconds (SEFS)
• Unavailable seconds (UAS)
Instrumentation (counters)
Layer 2 per-queue and per-channel packet and byte counters
Copyright © 2017, Juniper Networks, Inc.104
T4000 Core Router Interface Module Reference
PICs Supported in the Fourth Slot of T640-FPC2-E and T640-FPC2-E2with Type 2 IQE PICs
Table 73: PICs Supported in Fourth Slot of T640-FPC2-E and T640-FPC2-E2with Type 2 IQEPICs
PICModel NumberPIC Name
PB-2GE-SFPGigabit Ethernet, 2-port SFP
PB-4GE-SFPGigabit Ethernet, 4-port SFP
PB-2GE-SFP-QPPGigabit Ethernet IQ, 2-port SFP
PB-4OC12-SON-MMSONET/SDHOC12c/STM4, 4-port with multimode transceiversinstalled
PB-4OC12-SON-SMIRSONET/SDHOC12c/STM4, 4-port with single-mode intermediatereach transceivers installed
PB-1OC48–SON-SFPSONET/SDHOC48/STM16, 1-port SFP
PB-TUNNELTunnel Services
RelatedDocumentation
• T4000 PIC Description
• T4000 PICs Supported on page 3
105Copyright © 2017, Juniper Networks, Inc.
Chapter 5: Channelized Enhanced IQ (IQE) PIC Descriptions
Copyright © 2017, Juniper Networks, Inc.106
T4000 Core Router Interface Module Reference
CHAPTER 6
DS3 and E3 PIC Descriptions
• DS3/E3 Enhanced IQ (IQE) PIC (T4000 Router) on page 107
DS3/E3 Enhanced IQ (IQE) PIC (T4000 Router)
g002
618
• Junos OS Release 12.1R2 and later (Type 1)
For informationonwhichFPCs support thisPIC, see “T4000PIC/FPCCompatibility” onpage8.
Software release
• Four DS3 or E3 ports
• DS3 or E3 is configurable on a per-port granularity
• Power requirement: 0.51 A@ 48 V (24.7W)
• Model number: PB-4DS3-E3-IQE-BNC
Description
• Ports are numbered 0 through 3 top to bottomHardware features
107Copyright © 2017, Juniper Networks, Inc.
• Maximum transmission units (MTUs) of up to 9192 bytes
• Subrate and scrambling:
NOTE: Only DS3 interfaces support subrate and scrambling.
• Digital Link/Quick Eagle
• Kentrox
• Larscom
• ADTRAN
• Verilink (subrate: only port Amode)
NOTE: For DS3 interfaces, Verilink does not function if an IQE interface is paired with an IQinterface.
• Data service unit (DSU) functionality
• B3ZS line encoding
• Framing: M13, C-bit parity, framed clear channel
• Full bit error rate test (BERT)
• ANSI T1.403 FDL
• Internal and loop clocking
• DS3 far end alarm and control (FEAC) channel
• Local line, remote line, and remote playback loopback testing
• Simple Network Management Protocol (SNMP): DS3 MIB
• Quality of service (QoS) per channel: weighted round-robin (WRR), random early detection(RED), weighted random early detection (WRED)
• Enhanced fine-grained queuing per logical interface. See the Class of Service Feature Guide forRouting Devices for more information about class of service features.
• Encapsulations:
• Circuit cross-connect (CCC)
• Translational cross-connect (TCC)
• Extended Frame Relay for CCC and TCC
• Flexible Frame Relay
• Frame Relay
• Frame Relay for CCC
• Frame Relay for TCC
• Frame Relay port CCC
• High-Level Data Link Control (HDLC)
• HDLC framing for CCC
• HDLC framing for TCC
• MPLS CCC
• MPLS TCC
• Multilink Frame Relay (MLFR) UNI NNI (MFR FRF.16)
• Point-to-Point Protocol (PPP)
• PPP for CCC
• PPP for TCC
Software features
• Standard DS3 BNC coaxial cable interfacesCables and connectors
Copyright © 2017, Juniper Networks, Inc.108
T4000 Core Router Interface Module Reference
One tricolor per port:
• Off—Not enabled
• Green—Online with no alarms or failures
• Yellow—Online with alarms for remote failures
• Red—Active with a local alarm; router has detected a failure
LEDs
• DS3 alarms:
• Alarm indication signal (AIS)
• Loss of frame (LOF)
• Loss of signal (LOS)
• Phase lock loop (PLL)
• DS3 error detection:
• C-bit code violations (CCV)
• C-bit errored seconds (CES)
• C-bit severely errored framing seconds (CEFS)
• CRC errors
• Excessive zeros (EXZ)
• Far-end block error (FEBE)
• Far-end receive failure (FERF)
• Line errored seconds (LES)
• Parity bit (P-bit) code violations (PCV)
• Parity bit (P-bit) errored seconds (PES)
• Parity bit (P-bit) severely errored framing seconds (PSES)
• Severely errored framing seconds (SEFS)
• Unavailable seconds (UAS)
Alarms, errors, andevents
• Layer 2 per-queue and per-channel packet and byte countersInstrumentation(counters)
RelatedDocumentation
• T4000 PIC Description
• T4000 PICs Supported on page 3
109Copyright © 2017, Juniper Networks, Inc.
Chapter 6: DS3 and E3 PIC Descriptions
Copyright © 2017, Juniper Networks, Inc.110
T4000 Core Router Interface Module Reference
CHAPTER 7
Fast Ethernet PIC Descriptions
• Fast Ethernet PIC (T4000 Router) on page 111
Fast Ethernet PIC (T4000 Router)
• Junos OS Release 12.1R2 and later (Type 1)
For informationonwhichFPCs support thisPIC, see “T4000PIC/FPCCompatibility” onpage8.
Software release
• 4 100Base-TX ports
• Power requirement: 0.14 A@ 48 V (6.8W)
• Model number: PB-4FE-TX
Description
• High-performance throughput on each port at speeds up to 100Mbps
• Source and destination Media Access Control (MAC) address filtering
• RMON EtherStats packet buffering
• 802.3 Ethernet standard compliant
• MTUs up to 1533 bytes
• 1,024 autosensing 802.1q VLANs per port
Hardware features
• Autosensing full-duplex and half-duplex modes
• Virtual Router Redundancy Protocol (VRRP)
• 802.1q virtual LANs (VLANs)
• Circuit cross-connect (CCC) VLAN
Software features
111Copyright © 2017, Juniper Networks, Inc.
4-port PIC:
• Connector: Two-pair, Category 5 unshielded twisted-pair connectivity through an RJ-45connector
• Pinout: MDI noncrossover
Cables and connectors
Status LED, one bicolor:
• Off—PIC ports not enabled.
• Green—PIC is operating normally.
• Red—PIC has an error or failure.
4-port PIC—One pair of port LEDs:
• Link LED—If green, the port is online; if there is no light, the port is down.
• RX LED—If flashing green, the port is receiving data; if there is no light, the portmight be on butis not receiving data.
LEDs
RelatedDocumentation
• T4000 PIC Description
• T4000 PICs Supported on page 3
Copyright © 2017, Juniper Networks, Inc.112
T4000 Core Router Interface Module Reference
CHAPTER 8
Gigabit Ethernet PIC Descriptions
• Gigabit Ethernet PICs with SFP (T4000 Router) on page 113
• Gigabit Ethernet IQ PIC with SFP (T4000 Router) on page 116
• Gigabit Ethernet IQ2 PICs with SFP (T4000 Router) on page 119
• Gigabit Ethernet Enhanced IQ2 (IQ2E) PIC with SFP (T4000 Router) on page 122
Gigabit Ethernet PICs with SFP (T4000 Router)
Figure 6: 4-Port Gigabit Ethernet PICFigure 5: 2-Port Gigabit Ethernet PIC
• Software Release on page 114
• Hardware Features on page 114
• Software Features on page 114
• Cables and Connectors on page 115
• LEDs on page 116
113Copyright © 2017, Juniper Networks, Inc.
Software Release
• 2-port: Junos OS Release 12.2R2 and later (Type 2)
• 4-port: Junos OS Release 12.2R2 and later (Type 2)
• 10-port: Junos OS Release 12.1R2 and later (Type 3)
For information on which FPCs support this PIC, see “T4000 PIC/FPC Compatibility” on
page 8.
Hardware Features
• Ten Gigabit Ethernet ports
• Power requirement: 0.62 A@ 48 V (29.9W)
• Supports largeEthernet framesizes formoreefficient throughputacross the intra-POP
network
• Model number for 2-Port Gigabit Ethernet PIC: PB-2GE-SFP
• Model number for 4-Port Gigabit Ethernet PIC: PB-4GE-SFP
• Model number for 10-Port Gigabit Ethernet PIC: PC-10GE-SFP
• High-performance throughput on each port at speeds up to 1 Gbps
• Autonegotiation between Gigabit Ethernet circuit partners
• Full-duplex mode
• Maximum transmission units (MTUs) of up to 9192 bytes
Software Features
Table 74: Software Features Supported
T4000 First Supported Junos OS ReleaseSoftware Feature
12.2R2Virtual Router Redundancy Protocol (VRRP) support
12.2R2802.1q virtual LANs (VLANs) support
12.2R2960 destination MAC filters per port
12.2R2Optical diagnostics and related alarms
12.2R2Passive monitoring for IPv4 packets
Copyright © 2017, Juniper Networks, Inc.114
T4000 Core Router Interface Module Reference
NOTE: The 10-port Gigabit Ethernet PIC with SFP does not support MACaccounting and policing, MAC learning, TPID, or flexible Ethernetencapsulation.
The 10-port Gigabit Ethernet PIC supports 64 source MAC filters per port.
Cables and Connectors
• You can install any transceiver supported by the PIC.
• Fiber-optic SFP transceivers:
• Duplex LC/PC connector (Rx and Tx)
• 1000BASE-LH (model number: SFP-1GE-LH)
• 1000BASE-LX (model number: SFP-1GE-LX)
• 1000BASE-SX (model number: SFP-1GE-SX)
• Optical interface specifications—see “Gigabit Ethernet 1000BASE Optical Interface
Specifications” on page 30
• 1000BASE-BX (model number pairs: SFP-GE10KT13R14 with SFP-GE10KT14R13,
SFP-GE10KT13R15 with SFP-GE10KT15R13, SFP-GE40KT13R15 with
SFP-GE40KT15R13)—See “Fast Ethernet and Gigabit Ethernet Bidirectional SFP
Optical Interface Specifications” on page 27
• Copper transceiver:
• Connector: Four-pair, Category5 shielded twisted-pair connectivity throughanRJ-45
connector
• 1000BASE-T (model number: SFP-1GE-T)
• Pinout: MDI crossover
• Copper interfacespecifications—see “GigabitEthernet 1000BASE-TCopper Interface
Specifications” on page 34
NOTE: Donot installGigabit EthernetSFPs in theSONET/SDHport. Theportwill not recognize the SFP.
115Copyright © 2017, Juniper Networks, Inc.
Chapter 8: Gigabit Ethernet PIC Descriptions
LEDs
Table 75: Gigabit Ethernet PICs with SFP LEDs
DescriptionStateColorLabel
PIC is not enabled.Off—STATUS
PIC is operating normally.On steadilyGreen
PIC has an error or failure.On steadilyRed
The port is online.On steadilyGreenLINK for eachport
The port is down.Off—
The port is receiving data.FlashingGreenACT for each port
The port might be on but is not receiving data.Off—
RelatedDocumentation
T4000 PIC Description•
• T4000 PICs Supported on page 3
Gigabit Ethernet IQ PICwith SFP (T4000 Router)
Figure 7: 2-Port Gigabit Ethernet IQ PIC
• Software Release on page 117
• Hardware Features on page 117
• Software Features on page 117
• Cables and Connectors on page 117
• Gigabit Ethernet IQ PIC with SFP LEDs on page 118
Copyright © 2017, Juniper Networks, Inc.116
T4000 Core Router Interface Module Reference
Software Release
2-port: Junos OS Release 12.2R2 and later (Type 2):
For information on which FPCs support this PIC, see “T4000 PIC/FPC Compatibility” on
page 8.
Hardware Features
• Two Gigabit Ethernet ports
• Power requirement: 0.46 A@ 48 V (22W)
• Fine-grained queuing per logical interface
• Model number: PB-2GE-SFP-QPP
• High-performance throughput on each port at speeds up to 1 Gbps
• Full-duplex mode
• Large MTUs of up to 9192 bytes
Software Features
Table 76: Software Features Supported
T4000 First Supported Junos OSReleaseSoftware Feature
12.2R2Optical diagnostics and related alarms
12.2R2Quality of service (QoS) per channel: weighted round-robin (WRR), random earlydetection (RED), weighted random early detection (WRED)
12.2R2Virtual Router Redundancy Protocol (VRRP) support
12.2R2802.1q virtual LANs (VLANs)
12.2R2VLAN stacking and rewriting
12.2R2Flexible Ethernet encapsulation
12.2R2MAC policing, accounts, and filters
Cables and Connectors
• You can install any transceiver supported by the PIC.
• Fiber-optic small form-factor pluggable (SFP) transceivers:
• Duplex LC connector (Rx and Tx)
• 1000BASE-LH (model number: SFP-1GE-LH)
• 1000BASE-LX (model number: SFP-1GE-LX)
117Copyright © 2017, Juniper Networks, Inc.
Chapter 8: Gigabit Ethernet PIC Descriptions
• 1000BASE-SX (model number: SFP-1GE-SX)
• Optical interface specifications—see “Gigabit Ethernet 1000BASE Optical Interface
Specifications” on page 30
• 1000BASE-BX (model number pairs: SFP-GE10KT13R14 with SFP-GE10KT14R13,
SFP-GE10KT13R15 with SFP-GE10KT15R13, SFP-GE40KT13R15 with
SFP-GE40KT15R13)—See “Fast Ethernet and Gigabit Ethernet Bidirectional SFP
Optical Interface Specifications” on page 27
• Copper transceiver:
• Connector: Four-pair, Category5 shielded twisted-pair connectivity throughanRJ-45
connector
• 1000BASE-T (model number: SFP-1GE-T)
• Pinout: MDI crossover
• Copper interfacespecifications—see “GigabitEthernet 1000BASE-TCopper Interface
Specifications” on page 34
NOTE: Donot install SONET/SDHOC48c/STM16SFPs in aGigabit Ethernetport. The port will not recognize the SFP.
Gigabit Ethernet IQ PICwith SFP LEDs
Table 77: LEDs
DescriptionStateColorLabel
PIC is not enabled.Off—STATUS
At least one port is online.On steadilyGreen
Port is down.Off—LINK one per port
Link is established.On steadilyGreen
No activity.Off—ACTIVITY one perport
Link has activity.On steadilyGreen
RelatedDocumentation
T4000 PIC Description•
• T4000 PICs Supported on page 3
Copyright © 2017, Juniper Networks, Inc.118
T4000 Core Router Interface Module Reference
Gigabit Ethernet IQ2 PICs with SFP (T4000 Router)
Figure 9: 8-Port Gigabit Ethernet IQ2 PIC(Type 2)
Figure 8: 4-Port Gigabit Ethernet IQ2 PIC(Type 1)
• Software Release on page 119
• Hardware Features on page 119
• Software Features on page 120
• Cables and Connectors on page 120
• LEDs on page 121
Software Release
• 4-port: Junos OS Release 12.1R2 and later (Type 1)
• 8-port: Junos OS Release 12.2R2 and later (Type 2)
• 8-port: Junos OS Release 12.1R2 and later (Type 3)
For information on which FPCs support this PIC, see “T4000 PIC/FPC Compatibility” on
page 8.
Hardware Features
• Eight Gigabit Ethernet ports
• Power requirement: 1.25 A@48 V (60W)
• Model number for 4-Port Gigabit Ethernet IQ2 PIC: PB-4GE-TYPE1-SFP-IQ2
• Model number for 8-port Type 2 Gigabit Ethernet IQ2 PIC: PB-8GE-TYPE2-SFP-IQ2
• Model number for 8-port Type 3 Gigabit Ethernet IQ2 PIC: PC-8GE-TYPE3-SFP-IQ2
119Copyright © 2017, Juniper Networks, Inc.
Chapter 8: Gigabit Ethernet PIC Descriptions
• High-performance throughput: speeds up to 1 Gbps on each port
• Full-duplex mode
• Large maximum transmission units (MTUs) of up to 9192 bytes
Software Features
Table 78: Software Features Supported
T4000FirstSupportedJunosOSReleaseSoftware Feature
12.1R2Optical diagnostics and related alarms
12.1R2Qualityof service(QoS)perchannel:weighted round-robin (WRR), randomearlydetection(RED), weighted random early detection (WRED)
12.1R2Virtual Router Redundancy Protocol (VRRP) support
12.1R2Hierarchical shaping
12.1R2Fine-grained queuing and shaping per logical interface at both ingress and egress
12.1R2802.1q virtual LANs (VLANs)
12.1R2VLAN stacking and rewriting
12.1R2Channels defined by two stacked VLAN tags
12.1R2Multiple tag protocol identifiers (TPID) support
12.1R2IP service for nonstandard TPID and stacked VLAN tags
12.1R2802.1p rewrite per channel
12.1R2Flexible mapping of channels and scheduler resources at both ingress and egress
12.1R2Flexible Ethernet encapsulation
12.1R2MAC learning, policing, accounting, and filtering
Cables and Connectors
• You can install any transceiver supported by the PIC.
NOTE: Do not install SONET/SDH SFPs in the Gigabit Ethernet port. Theport will not recognize the SFP.
• Fiber-optic SFP transceivers:
Copyright © 2017, Juniper Networks, Inc.120
T4000 Core Router Interface Module Reference
• Duplex LC connector (Rx and Tx)
• 1000BASE-LH (model number: SFP-1GE-LH)
• 1000BASE-LX (model number: SFP-1GE-LX)
• 1000BASE-SX (model number: SFP-1GE-SX)
• Optical interface specifications—see “Gigabit Ethernet 1000BASE Optical Interface
Specifications” on page 30
• 1000BASE-BX (model number pairs: SFP-GE10KT13R14 with SFP-GE10KT14R13,
SFP-GE10KT13R15 with SFP-GE10KT15R13, SFP-GE40KT13R15 with
SFP-GE40KT15R13)—See “Fast Ethernet and Gigabit Ethernet Bidirectional SFP
Optical Interface Specifications” on page 27
• Copper transceiver:
• Connector: Four-pair, Category5 shielded twisted-pair connectivity throughanRJ-45
connector
• 1000BASE-T (model number: SFP-1GE-T)
• Pinout: MDI crossover
• Copper interfacespecifications—see “GigabitEthernet 1000BASE-TCopper Interface
Specifications” on page 34
LEDs
Table 79: Gigabit Ethernet IQ2 PICs with SFP LEDs
DescriptionStateColorLabel
PIC is offline and it is safe to remove it from the router.Off—OK or StatusLED, onetricolor PIC is operating normally.On steadilyGreen
PIC is initializing.On steadilyYellow
PIC has an error or failure.On steadilyRed
RelatedDocumentation
T4000 PIC Description•
• T4000 PICs Supported on page 3
121Copyright © 2017, Juniper Networks, Inc.
Chapter 8: Gigabit Ethernet PIC Descriptions
Gigabit Ethernet Enhanced IQ2 (IQ2E) PICwith SFP (T4000 Router)
Figure 10: 8-Port Gigabit Ethernet IQ2E PIC (Type 3)
g004
422
• Software Release on page 122
• Hardware Features on page 122
• Software Features on page 123
• Cables and Connectors on page 124
• LEDs on page 124
Software Release
8-port: Junos OS Release 12.1R2 and later (Type 3)
For information on which FPCs support this PIC, see “T4000 PIC/FPC Compatibility” on
page 8.
Hardware Features
• Eight Gigabit Ethernet ports
• Power requirement:
• 8-port (Type 3): 1.25 A@48 V (60W)
• Model number: PC-8GE-TYPE3-SFP-IQ2E
• High-performance throughput: speeds up to 1 Gbps on each port
• Full-duplex mode
• Large maximum transmission units (MTUs) of up to 9192 bytes
Copyright © 2017, Juniper Networks, Inc.122
T4000 Core Router Interface Module Reference
Software Features
Table 80: Software Features Supported
T4000 First Supported JunosOS ReleaseSoftware Feature
12.1R2Optical diagnostics and related alarms
12.1R2Quality of service (QoS) per channel: weighted round-robin (WRR), randomearly detection(RED), weighted random early detection (WRED)
12.1R2Drop statistics reported per queue for each of four priority-based drop profiles
12.1R2Four levels of strict priorities with priority propagation among scheduling levels
12.1R2Hierarchical shaping and hierarchical scheduler
12.1R2Virtual Router Redundancy Protocol (VRRP) support
12.1R2Fine-grained queuing and shaping per logical interface at both ingress and egress
12.1R2802.1q virtual LANs (VLANs)
12.1R2VLAN stacking and rewriting
12.1R2Channels defined by two stacked VLAN tags
12.1R2Multiple tag protocol identifiers (TPID) support
12.1R2IP service for nonstandard TPID and stacked VLAN tags
12.1R2802.1p rewrite per channel
12.1R2Flexible mapping of channels and scheduler resources at both ingress and egress
12.1R216,000schedulers (2,000schedulerswith8queueseachor4,000schedulerswith4queueseach)
12.1R2Scheduler resources dynamically allocated across ports
12.1R2Flexible Ethernet encapsulation
12.1R2MAC learning, policing, accounting, and filtering
123Copyright © 2017, Juniper Networks, Inc.
Chapter 8: Gigabit Ethernet PIC Descriptions
Cables and Connectors
• You can install any transceiver supported by the PIC.
NOTE: Do not install SONET/SDH SFPs in the Gigabit Ethernet port. Theport will not recognize the SFP.
• Fiber-optic small form-factor pluggable transceivers (SFPs):
• Duplex LC connector (Rx and Tx)
• Small form-factor pluggable (SFP) transceivers:
• 1000BASE-LH (model number: SFP-1GE-LH)
• 1000BASE-LX (model number: SFP-1GE-LX)
• 1000BASE-SX (model number: SFP-1GE-SX)
• Optical interfacespecifications—see “Gigabit Ethernet 1000BASEOptical Interface
Specifications” on page 30
• 1000BASE-BX (model number pairs: SFP-GE10KT13R14 with SFP-GE10KT14R13,
SFP-GE10KT13R15 with SFP-GE10KT15R13, SFP-GE40KT13R15 with
SFP-GE40KT15R13)—See “Fast Ethernet and Gigabit Ethernet Bidirectional SFP
Optical Interface Specifications” on page 27
• Copper transceiver:
• Connector: Four-pair, Category5 shielded twisted-pair connectivity throughanRJ-45
connector
• 1000BASE-T (model number: SFP-1GE-T)
• Pinout: MDI crossover
Copper interface specifications—see “Gigabit Ethernet 1000BASE-T Copper Interface
Specifications” on page 34
LEDs
Table 81: Gigabit Ethernet Enhanced IQ2 (IQ2E) PICwith SFP LEDs
DescriptionStateColorLabel
PIC is offline and it is safe to remove it from the router.Off—OK or Status LED,one tricolor
PIC is operating normally.On steadilyGreen
PIC is initializing.On steadilyYellow
PIC has an error or failure.On steadilyRed
Copyright © 2017, Juniper Networks, Inc.124
T4000 Core Router Interface Module Reference
Table 81: Gigabit Ethernet Enhanced IQ2 (IQ2E) PICwith SFP LEDs (continued)
DescriptionStateColorLabel
Monitoring application is not running.Off—APP LED, onebicolor
Monitoring application is running under acceptableload.
On steadilyGreen
Port is not enabled.Off—Port LEDs, labeled0 through9, oneperport Port is online with no alarms or failures.On steadilyGreen
RelatedDocumentation
• T4000 PIC Description
• T4000 PICs Supported on page 3
125Copyright © 2017, Juniper Networks, Inc.
Chapter 8: Gigabit Ethernet PIC Descriptions
Copyright © 2017, Juniper Networks, Inc.126
T4000 Core Router Interface Module Reference
CHAPTER 9
10-Gigabit Ethernet PIC Descriptions
• 10-Gigabit Ethernet PIC with XENPAK (T4000 Router) on page 127
• 10-Gigabit Ethernet IQ2 PIC with XFP (T4000 Router) on page 130
• 10-Gigabit Ethernet IQ2E PIC with XFP (T4000 Router) on page 133
• 10-Gigabit Ethernet LAN/WAN PIC with SFP+ (T4000 Router) on page 136
• 10-Gigabit Ethernet LAN/WAN PIC with Oversubscription and SFP+ (T4000
Router) on page 140
• 10-Gigabit Ethernet LAN/WAN PIC with XFP (T4000 Router) on page 147
10-Gigabit Ethernet PIC with XENPAK (T4000 Router)
• Software Release on page 128
• Hardware Features on page 128
• Software Features on page 128
• Cables and Connectors on page 128
• LEDs on page 129
127Copyright © 2017, Juniper Networks, Inc.
Software Release
Junos OS Release 12.2R2 and later (Type 3)
For information on which FPCs support this PIC, see “T4000 PIC/FPC Compatibility” on
page 8.
Hardware Features
• One 10-Gigabit Ethernet port
• Power requirement: 0.55 A@ 48 V (26.6W)
• Supports largeEthernet framesizes formoreefficient throughputacross the intra-POP
network
• Model number: PC-1XGE-XENPAK
• High-performance throughput at speeds up to 10 Gbps
• Full-duplex mode
• Maximum transmission units (MTUs) up to 9192 bytes
• 64 source MAC address filters
• 960 destination MAC filters
Software Features
Table 82: Software Features Supported
T4000 First Supported Junos OSReleaseSoftware Feature
12.2R2Virtual Router Redundancy Protocol (VRRP) support
12.2R2802.1q virtual LANs (VLANs) support
12.2R2IEEE 802.3ad Link Aggregation
12.2R2RMON EtherStats
12.2R2Optical diagnostics and related alarms :
• Transceiver temperature
• Laser bias current
• Laser output power
• Receive optical power
Cables and Connectors
• Duplex SC connector (RX and TX)
• 10-Gigabit Ethernet XENPAK transceivers:
Copyright © 2017, Juniper Networks, Inc.128
T4000 Core Router Interface Module Reference
• 10GBASE-SR, LAN Rate (model number: XENPAK-1XGE-SR)
• 10GBASE-LR, LAN Rate (model number: XENPAK-1XGE-LR)
• 10GBASE-ER, LAN Rate (model number: XENPAK-1XGE-ER)
• 10GBASE-ZR, LAN Rate (model number: XENPAK-1XGE-ZR) EOL (see
PSN-2010-02-649)
Optical interface specifications—see “10-Gigabit Ethernet 10GBASE Optical Interface
Specifications” on page 34
LEDs
Table 83: 10-Gigabit Ethernet PIC with XENPAK LEDs
DescriptionStateColorLabel
PIC is not enabled.Off—STATUS
PIC is operating normally.On steadilyGreen
PIC has an error or failure.On steadilyRed
The port is down.Off—Port LED LINK
The port is online.On steadilyGreen
The port might be on but is not receiving data.Off—Port LED Rx
The port is receiving data.On steadilyGreen
RelatedDocumentation
T4000 PIC Description•
• T4000 PICs Supported on page 3
129Copyright © 2017, Juniper Networks, Inc.
Chapter 9: 10-Gigabit Ethernet PIC Descriptions
10-Gigabit Ethernet IQ2 PICwith XFP (T4000 Router)
• Software Release on page 130
• Hardware Features on page 130
• Software Features on page 131
• Cables and Connectors on page 131
• LEDs on page 132
Software Release
Junos OS Release 12.1R2 and later (Type 3)
For information on which FPCs support this PIC, see “T4000 PIC/FPC Compatibility” on
page 8.
Hardware Features
• One 10-Gigabit Ethernet port
• Power requirements: 1.2 A@48 V (56W)
• Model number: PC-1XGE-TYPE3-XFP-IQ2
• High-performance throughput
• WAN-PHYmode at 9.953 Gbps
• LAN-PHYmode at 10.3125 Gbps
• Full-duplex mode
• Large maximum transmission units (MTUs) of up to 9192 bytes
Copyright © 2017, Juniper Networks, Inc.130
T4000 Core Router Interface Module Reference
Software Features
Table 84: Software Features Supported
T4000FirstSupportedJunosOSReleaseSoftware Feature
12.1R2Qualityof service(QoS)perchannel:weighted round-robin(WRR), randomearlydetection(RED), weighted random early detection (WRED)
12.1R2ConfigurableWAN-PHYmode options:
• loopback
• mpls
• path-trace
• trigger
12.1R2Virtual Router Redundancy Protocol (VRRP) support
12.1R2Hierarchical shaping
12.1R2Fine-grained queuing and shaping per logical interface at both ingress and egress
12.1R2802.1q virtual LANs (VLANs)
12.1R2VLAN stacking and rewriting
12.1R2Channels defined by two stacked VLAN tags
12.1R2Multiple tag protocol identifiers (TPID) support
12.1R2IP service for nonstandard TPID and stacked VLAN tags
12.1R2802.1p rewrite per channel
12.1R2Flexible mapping of channels and scheduler resources at both ingress and egress
12.1R2Flexible Ethernet encapsulation
12.1R2MAC learning, policing, accounting, and filtering
Cables and Connectors
• You can install any transceiver supported by the PIC.
• Fiber-optic 10-Gigabit small form-factor pluggable (XFP) transceivers:
• Duplex LC connector (Rx and Tx)
• 10-Gigabit Ethernet XFP transceivers:
131Copyright © 2017, Juniper Networks, Inc.
Chapter 9: 10-Gigabit Ethernet PIC Descriptions
• 10GBASE-S (model number: XFP-10G-S)
• 10GBASE-L (model number: XFP-10G-L-OC192-SR1)
• 10GBASE-E (model number: XFP-10G-E-OC192-IR2)
• 10GBASE-Z (model number: XFP-10G-Z-OC192-LR2)
Optical interfacespecifications—see “10-Gigabit Ethernet 10GBASEOptical Interface
Specifications” on page 34
LEDs
Table 85: 10-Gigabit Ethernet IQ2 PICwith XFP LEDs
DescriptionStateColorLabel
PIC is offline and safe to remove from the router.Off—OK LED, onetricolor
PIC is operating normally.On steadilyGreen
PIC is initializing.On steadilyYellow
PIC has an error or failure.On steadilyRed
Monitoring application is not running.Off—APP LED
Monitoring application is overloaded.On steadilyYellow
Monitoring application is running under acceptable load.On steadilyGreen
Port is down.Off—LINKSTATUSLED
Port is online. Link is established.On steadilyGreen
RelatedDocumentation
T4000 PIC Description•
• T4000 PICs Supported on page 3
Copyright © 2017, Juniper Networks, Inc.132
T4000 Core Router Interface Module Reference
10-Gigabit Ethernet IQ2E PICwith XFP (T4000 Router)
g004
423
• Software Release on page 133
• Hardware Features on page 133
• Software Features on page 134
• Cables and Connectors on page 135
• LEDs on page 135
Software Release
Junos OS Release 12.1R2 and later (Type 3)
For information on which FPCs support this PIC, see “T4000 PIC/FPC Compatibility” on
page 8.
Hardware Features
• One 10-Gigabit Ethernet port
• Power requirements: 1.2 A@48 V (56W)
• Model number: PC-1XGE-TYPE3-XFP-IQ2E
• High-performance throughput
• WAN-PHYmode at 9.953 Gbps
• LAN-PHYmode at 10.3125 Gbps
• Full-duplex mode
• Large maximum transmission units (MTUs) of up to 9192 bytes
133Copyright © 2017, Juniper Networks, Inc.
Chapter 9: 10-Gigabit Ethernet PIC Descriptions
Software Features
Table 86: Software Features Supported
T4000FirstSupported JunosOS ReleaseSoftware Feature
12.1R2Quality of service (QoS) per channel: weighted round-robin (WRR), random early detection(RED), weighted random early detection (WRED)
12.1R2Drop statistics reported per queue for each of four priority-based drop profiles
12.1R2Four levels of strict priorities with priority propagation among scheduling levels
12.1R2Hierarchical shaping and hierarchical scheduler
12.1R2ConfigurableWAN-PHYmode options:
• loopback
• mpls
• path-trace
• trigger
12.1R2Virtual Router Redundancy Protocol (VRRP) support
12.1R2Fine-grained queueing and shaping per logical interface at both ingress and egress
12.1R2802.1q virtual LANs (VLANs)
12.1R2VLAN stacking and rewriting
12.1R2Channels defined by two stacked VLAN tags
12.1R2Multiple tag protocol identifiers (TPID) support
12.1R2IP service for nonstandard TPID and stacked VLAN tags
12.1R2802.1p rewrite per channel
12.1R2Flexible mapping of channels and scheduler resources at both ingress and egress
12.1R216,000schedulers (2,000schedulerswith8queueseachor4,000schedulerswith4queueseach)
12.1R2Scheduler resources dynamically allocated across ports
12.1R2Flexible Ethernet encapsulation
12.1R2MAC learning, policing, accounting, and filtering
Copyright © 2017, Juniper Networks, Inc.134
T4000 Core Router Interface Module Reference
Cables and Connectors
• You can install any transceiver supported by the PIC.
• Fiber-optic 10-Gigabit small form-factor pluggable (XFP) transceivers:
• Duplex LC connector (Rx and Tx)
• 10-Gigabit Ethernet XFP transceivers:
• 10GBASE-S (model number: XFP-10G-S)
• 10GBASE-L (model number: XFP-10G-L-OC192-SR1)
• 10GBASE-E (model number: XFP-10G-E-OC192-IR2)
• 10GBASE-Z (model number: XFP-10G-Z-OC192-LR2)
Optical interfacespecifications—see “10-Gigabit Ethernet 10GBASEOptical Interface
Specifications” on page 34
LEDs
Table 87: 10-Gigabit Ethernet IQ2E PICwith XFP LEDs
DescriptionStateColorLabel
PIC is offline and safe to remove from the router.Off—OK LED, onetricolor
PIC is operating normally.On steadilyGreen
PIC is initializing.On steadilyYellow
PIC has an error or failure.On steadilyRed
Monitoring application is not running.Off—APP LED
Monitoring application is overloaded.On steadilyYellow
Monitoring application is running under acceptable load.On steadilyGreen
Port is down.Off—LINKSTATUSLED
Port is online. Link is established.On steadilyGreen
RelatedDocumentation
T4000 PIC Description•
• T4000 PICs Supported on page 3
135Copyright © 2017, Juniper Networks, Inc.
Chapter 9: 10-Gigabit Ethernet PIC Descriptions
10-Gigabit Ethernet LAN/WANPICwith SFP+ (T4000 Router)
g006294
• Software Release on page 136
• Hardware Features on page 136
• Software Features on page 137
• Cables and Connectors on page 138
• LEDs on page 139
• Alarms on page 139
Software Release
Junos OS Release 12.1 and later (Type 5)
For informationaboutwhichFPCssupport thesePICs, see “T4000PIC/FPCCompatibility”
on page 8.
Hardware Features
• Twelve 10-Gigabit Ethernet SFP+ ports
• Power requirements: 0.69 A@48 V (33W)
Copyright © 2017, Juniper Networks, Inc.136
T4000 Core Router Interface Module Reference
• Model number: PF-12XGE-SFPP
• ONLINE/OFFLINE button
• Large maximum transmission units (MTUs) of up to 9192 bytes
Software Features
Table 88: Software Features Supported
T4000 First SupportedJunos OS ReleaseSoftware Feature
12.1R1LAN-PHYmode selectable per port
12.1R2WAN-PHYmode selectable per port
12.1R1Interface hold timer
12.1R1SNMP support to access all 10 Gigabit Ethernet port counters
12.1R2Graceful Routing Engine switchover (GRES) support
12.1R1Layer 2 protocols:
• Flexible Ethernet service
• Ethernet circuit cross-connect (CCC)
• Ethernet translational Ethernet circuit cross-connect (TCC)
• Ethernet VPLS
• VLAN CCC
• Extended VLAN CCC
• Extended VLAN TCC
• VLAN VPLS
12.1R1Layer 3 protocols:
• IPv4
• IPv6
• MPLS
12.1R2MAC filtering, accounting, policing, and learning for source media access control (MAC) onlogical interfaces
12.1R1Flexible encapsulation
12.1R1Single, stacked, and flexible VLAN tagging modes
12.1R1Native VLAN configuration to allow untagged frames to be received on the tagged interfaces
12.1R1IEEE 802.3ad link aggregation (on single chassis)
137Copyright © 2017, Juniper Networks, Inc.
Chapter 9: 10-Gigabit Ethernet PIC Descriptions
Table 88: Software Features Supported (continued)
T4000 First SupportedJunos OS ReleaseSoftware Feature
12.1R1Defining the VLAN rewrite operation to be applied to the incoming and outgoing frames onlogical interfaces on this PIC.
NOTE: Only the Tag Protocol Identifier (TPID) 0x8100 is supported.
12.1R1Interoperabilitywith other 10-Gigabit EthernetPICsonMSeries andTSeries routers in LAN-PHYandWAN-PHYmodes.
12.1R1Behavior aggregate (BA) classification (IPv4 DSCP, IPv6 DSCP, Inet precedence, IEEE 802.1P,IEEE 802.1AD, MPLS EXP) and fixed classification.
13.3R1Support for mixed-mode configuration for dual rate of 1 Gbps or 10 Gbps.
Cables and Connectors
You can install any transceiver supported by the PIC.
• Duplex LC connector (Rx and Tx)
• Fiber-optic 10-Gigabit small form-factor pluggable (SFP+) transceivers
NOTE: For configuring 1-Gbps speed, SFP optics is required; SFPP doesnot support 1 Gbps.
• 10GBASE-SR (model number: SFPP-10GE-SR)
• 10GBASE-LR (model number: SFPP-10GE-LR)
• 10GBASE-ER (model number: SFPP-10GE-ER): Junos OS Release 12.1R2 and later
• 10GBASE-ZR (model number: SFPP-10GE-ZR): Junos OS Release 12.3 and later
• 10GBASE-ZR (model number: SFPP-10G-OTN-XT)
• Supported in Junos OS Release 12.3R5, 13.2R3, 13.3, and later
• NESB compliant
• Dual-rate extended temperature transceiver that supports LAN-PHYandWAN-PHY
modes, and OTN rates
Optical interface specifications—see “10-Gigabit Ethernet 10GBASE Optical Interface
Specifications” on page 34
Copyright © 2017, Juniper Networks, Inc.138
T4000 Core Router Interface Module Reference
LEDs
Table 89: 10-Gigabit Ethernet LAN/WANPICwith SFP+ LEDs
DescriptionStateColorLabel
PIC is powered down and offline.Off—STATUS
PIC is online with all voltages in range.On steadilyGreen
PIC is initializing.On steadilyYellow
PIC has an error or failure.On steadilyRed
Alarms
Alarms are vendor-specific. Some transceiver vendors might not support every alarm.
• Input laser power
• Input loss of lock
• Input loss of signal
• Input Rx path
• Output A/D data not ready
• Output CDR (clock data recovery)
• Output laser bias current
• Output laser power
• Output laser safety
• Output Tx path
• Module temperature
• Module MOD_NR (module not ready)
• Module P_DOWN (module down)
• Module unplugged or down
• Wire unplugged or down
RelatedDocumentation
T4000 PIC Description•
• T4000 PICs Supported on page 3
139Copyright © 2017, Juniper Networks, Inc.
Chapter 9: 10-Gigabit Ethernet PIC Descriptions
10-Gigabit Ethernet LAN/WANPICwith Oversubscription and SFP+ (T4000 Router)
Figure 12: 24-Port Type 5 PICwithOversubscription
g006295
24 PORT ETHERNET10GBASE-SFP+ LAN-WAN
STATUS
ONLINE /
10
32
54
76
98
1110
OFFLINE
1312
1514
1716
1918
2120
2322
Figure 11: 10-Port Type 4 PICwithOversubscription
PRIMARY
g004436
• Software Release on page 140
• Hardware Features on page 141
• Software Features on page 141
• Cables and Connectors on page 144
• LEDs on page 145
• Alarms, Errors, and Events on page 146
Software Release
• Junos OS Release 12.1R2 and later (Type 4)
NOTE: In some Juniper Networks documentation, the 10-Gigabit EthernetLAN/WANPICwithSFP+(PD-5-10XGE-SFPP) is referred toas the 10-port10-Gigabit Oversubscribed Ethernet PIC or 10-port 10-Gigabit OSE PIC.
In oversubscribed Ethernet mode (default), all 10 ports are enabled andoversubscription is permitted. In line-ratemode, this PIC does not allowoversubscription and supports only 5 ports (0, 2, 4, 6, and 8).
• Junos OS Release 12.2 and later (Type 5)
Copyright © 2017, Juniper Networks, Inc.140
T4000 Core Router Interface Module Reference
NOTE: InoversubscribedEthernetmode(default), all 24portsareenabledandoversubscription ispermitted. In line-ratemode, thisPICdoesnotallowoversubscription and supports only 12 ports (0 through 11).
For informationaboutwhichFPCssupport thesePICs, see “T4000PIC/FPCCompatibility”
on page 8.
Hardware Features
Type 4 PIC
• Ten 10-Gigabit EthernetSFP+ports (onlyports0,2,4,6, and8are supported in line-rate
mode)
• Total bandwidth: 50 Gbps
• Power requirements: 3.3 A@ –48 V (158.4W)
• Model number for 10-port Type 4 PIC with Oversubscription: PD-5-10XGE-SFPP
• High-performance throughput:
• WAN-PHYmode at 9.953 Gbps
• LAN-PHYmode at 10.3 Gbps
• Full-duplex mode
• Large maximum transmission units (MTUs) of up to 9192 bytes
Type 5 PIC
• Twenty-four 10-Gigabit Ethernet SFP+ ports (only ports 0 through 11 are supported in
line-rate mode)
• Power requirements: 0.94 A@48 V (45W)
• Model number for 24-Port Type 5 PIC with Oversubscription: PF-24XGE-SFPP
Software Features
Table 90: Software Features Supported on 10-Port Type 4 PICwith Over subscription
T4000 First Supported Junos OS ReleaseSoftware Feature
12.1R2Twomodes of operation: 5 ports in line-rate mode, 10 ports inoversubscribedmode
12.1R2Intelligent handling of oversubscribed traffic
12.1R2Flexible mapping of port-assigned queues and scheduler resources atboth ingress and egress
12.1R2Strict-priority queue available on a per-port basis
141Copyright © 2017, Juniper Networks, Inc.
Chapter 9: 10-Gigabit Ethernet PIC Descriptions
Table90:SoftwareFeaturesSupportedon10-PortType4PICwithOversubscription(continued)
T4000 First Supported Junos OS ReleaseSoftware Feature
12.1R2QoS available on a per-port basis
12.1R2Weighted round-robin (WRR)
12.1R2Layer 2 Protocol support:
• Ethernet CCC, Ethernet TCC, Ethernet VPLS
• VLAN CCC
• Extended VLAN TCC
• VLAN VPLS
• Flexible Ethernet services
12.1R2Layer 3 Protocol support
• IPv4
• IPv6
• MPLS
12.1R2VLAN support
• 4000 VLANs per PIC
• Flex-VLAN tagging support
• Interrupt driven link-down detection
• Pause frame support
• Jumbo frame support
12.1R2MAC learning, aging, and filtering
12.1R2MAC policing
12.1R2Virtual Router Redundancy Protocol (VRRP) support
12.1R2IEEE 802.3ad link aggregation (For routers in a routing matrix, Junos OSRelease 11.2 and later is required)
NOTE: ForPICSthatsupportoversubscription, thePICmustbe in line-ratemode to support aggregated Ethernet.
12.1R2DSCP rewrite
Table 91: Software Features Supported on 24-Port Type 5 PICwith Oversubscription
T4000 First Supported Junos OS ReleaseSoftware Feature
12.2R1Modes of operation:
• 12 ports in line-rate mode
• 24 ports in oversubscribedmode
Copyright © 2017, Juniper Networks, Inc.142
T4000 Core Router Interface Module Reference
Table91:SoftwareFeaturesSupportedon24-PortType5PICwithOversubscription(continued)
T4000 First Supported Junos OS ReleaseSoftware Feature
13.3R1Mixed-rate mode operation(configurable 1-Gbps or 10-Gbps speed)
12.2R1Intelligent handling of oversubscribed traffic
12.2R1LAN-PHYmode orWAN-PHYmode selectable per port
12.2R1IEEE 802.3ad link aggregation (on single chassis) (For routers ina routing matrix, Junos OS Release 11.2 and later is required)
NOTE: For PICs that support oversubscription, the PICmust be inline-rate mode to support aggregated Ethernet.
12.2R1Interface hold timer
12.2R1Graceful Routing Engine switchover (GRES)
12.2R1SNMP support to access all 10 Gigabit Ethernet port counters
12.2R1Layer 2 Protocol support:
• Ethernet CCC, Ethernet TCC, Ethernet VPLS
• VLAN CCC
• Extended VLAN TCC
• VLAN VPLS
• Flexible Ethernet services
12.2R1Layer 3 Protocol support
• IPv4
• IPv6
• MPLS
12.2R1MAC filtering, accounting, policing, and learning for source mediaaccess control (MAC) on logical interfaces
12.2R1Flexible encapsulation
12.2R1Single, stacked, and flexible VLAN tagging modes
12.2R1NativeVLANconfiguration toallowuntagged frames tobe receivedon the tagged interfaces
12.2R1IEEE 802.3ad Link Aggregation (on single chassis)
NOTE: For PICS that support oversubscription, the PICmust bein line-rate mode to support aggregated Ethernet.
143Copyright © 2017, Juniper Networks, Inc.
Chapter 9: 10-Gigabit Ethernet PIC Descriptions
Table91:SoftwareFeaturesSupportedon24-PortType5PICwithOversubscription(continued)
T4000 First Supported Junos OS ReleaseSoftware Feature
12.2R1Defining theVLAN rewrite operation to be applied to the incomingand outgoing frames on logical interfaces on this PIC.
NOTE: Only the Tag Protocol Identifier (TPID) 0x8100 issupported.
12.2R1Interoperability with other 10-Gigabit Ethernet PICs on M Seriesand T Series routers in LAN-PHY andWAN-PHYmodes.
12.2R1Behavior aggregate (BA) classification (IPv4 DSCP, IPv6 DSCP,Inet precedence, IEEE 802.1P, IEEE 802.1AD, MPLS EXP) and fixedclassification.
Cables and Connectors
You can install any transceiver supported by the PIC.
• Duplex LC/PC connector (Rx and Tx)
• Fiber-optic 10-Gigabit small form-factor pluggable (SFP+) transceivers.
NOTE: For 1-Gigabit speed, SFP optics is required; SFPP does not support1-Gigabit.
Type 4 PIC:
• 10GBASE-ER (model number: SFPP-10GE-ER)
• 10GBASE-LR (model number: SFPP-10GE-LR)
• 10GBASE-SR (model number: SFPP-10GE-SR)
• 10BASE-ZR (model number: SFPP-10GE-ZR): Junos OS Release 12.3 and later
• 10GBASE-ZR (model number: SFPP-10G-OTN-XT)
• Supported in Junos OS Release 12.3R5, 13.2R3, 13.3, and later
• NESB compliant
• Dual-rateextendedtemperature transceiver thatsupportsLAN-PHYandWAN-PHY
modes, and OTN rates
Type 5 PIC:
• 10GBASE-SR (model number: SFPP-10GE-SR)
• 10GBASE-LR (model number: SFPP-10GE-LR)
• 10GBASE-ER (model number: SFPP-10GE-ER): Junos OS Release 12.1R2 and later
Copyright © 2017, Juniper Networks, Inc.144
T4000 Core Router Interface Module Reference
• 10BASE-ZR (model number: SFPP-10GE-ZR): Junos OS Release 12.3 and later
• 10GBASE-ZR (model number: SFPP-10G-OTN-XT)
• Supported in Junos OS Release 12.3R5, 13.2R3, 13.3, and later
• NESB compliant
• Dual-rateextendedtemperature transceiver thatsupportsLAN-PHYandWAN-PHY
modes, and OTN rates
Optical interface specifications—see “10-Gigabit Ethernet 10GBASE Optical Interface
Specifications” on page 34
• 1000BASE-SX (model number: SFP-1GE-SX)
• 1000BASE-LX (model number: SFP-1GE-LX)
Optical interface specifications—see “Gigabit Ethernet 1000BASE Optical Interface
Specifications” on page 30
LEDs
Port LEDs, onepair for eachport. Theports on theType4PIC are labeledPORT0 through
PORT 9. The ports on the Type 5 PIC are labeled 0 through 23.
The link status LEDs on the Type 4 PIC are labeled LINK. The Type 5 PIC has no labels
for the link status LED.
The link activity LED on the Type 4 PIC is labeled ACT. The Type 5 PIC has no label for
the link activity LED.
Table 92: 10-Gigabit Ethernet LAN/WANPICwith Oversubscription and SFP+ LEDs
DescriptionStateColorLabel
PIC is offline and safe to remove from the router.Off—STATUS
PIC is operating normally.On steadilyGreen
PIC is initializing.On steadilyYellow
PIC has an error or failure.On steadilyRed
Port is not enabled.Off—Port LEDLINK
Port is online with no alarms or failures.On steadilyGreen
The router has detected a failure with alarms.On steadilyRed
No packet activity detected on the port.Off—Link activityLED ACT
Port is sending or receiving packets.On steadilyGreen
145Copyright © 2017, Juniper Networks, Inc.
Chapter 9: 10-Gigabit Ethernet PIC Descriptions
Alarms, Errors, and Events
Alarms are vendor-specific. Some transceiver vendors might not support every alarm.
• Input laser power
• Input loss of lock
• Input loss of signal
• Input Rx path
• Output A/D data not ready
• Output CDR (clock data recovery)
• Output laser bias current
• Output laser power
• Output laser safety
• Output Tx path
• Module temperature
• Module MOD_NR (module not ready)
• Module P_DOWN (module down)
• Module unplugged or down
• Wire unplugged or down
RelatedDocumentation
T4000 PIC Description•
• T4000 PICs Supported on page 3
Copyright © 2017, Juniper Networks, Inc.146
T4000 Core Router Interface Module Reference
10-Gigabit Ethernet LAN/WANPICwith XFP (T4000 Router)
• Software Release on page 147
• Hardware Features on page 147
• Software Features on page 148
• Cables and Connectors on page 148
• LEDs on page 149
• Alarms, Errors, and Events on page 149
Software Release
Junos OS Release 12.1R2 and later (Type 4)
For information on which FPCs support this PIC, see “T4000 PIC/FPC Compatibility” on
page 8.
Hardware Features
• Four 10-Gigabit Ethernet ports
• Power requirements: 0.9 A@48 V (43W)
• Model number: PD-4XGE-XFP
• High-performance throughput
• WAN-PHYmode at 9.953 Gbps
147Copyright © 2017, Juniper Networks, Inc.
Chapter 9: 10-Gigabit Ethernet PIC Descriptions
• LAN-PHYmode at 10.3125 Gbps
• Full-duplex mode
• Large maximum transmission units (MTUs) of up to 9192 bytes
Software Features
Table 93: Software Features Supported
T4000 First Supported Junos OSReleaseSoftware Feature
12.1R2ConfigurableWAN-PHYmode options:
• loopback
• mpls
• path-trace
• trigger
12.1R2Optical diagnostics, monitoring, and alarms
12.1R2Flexible Ethernet Services Encapsulation
12.1R2802.1q virtual LANs (VLANs)
12.1R2Ethernet OAM 802.1ag continuity check
12.1R2Ethernet OAM 802.3ah (remote loopback is not supported for this PIC)
12.1R2VLAN stacking
12.1R2Channels defined by two stacked VLAN tags
12.1R2Multiple tag protocol identifiers (TPID) support
12.1R2IP service for nonstandard TPID and stacked VLAN tags
12.1R2MAC learning, accounting, and filtering
12.1R2Virtual Router Redundancy Protocol (VRRP) support
Cables and Connectors
You can install any transceiver supported by the PIC.
• Connector: Duplex LC (Rx and Tx)
• Fiber-optic 10-Gigabit small form-factor pluggable (XFP) transceivers:
• 10GBASE-S (model number: XFP-10G-S)
• 10GBASE-L (model number: XFP-10G-L-OC192-SR1)
Copyright © 2017, Juniper Networks, Inc.148
T4000 Core Router Interface Module Reference
• 10GBASE-E (model number: XFP-10G-E-OC192-IR2)
• 10GBASE-Z (model number: XFP-10G-Z-OC192-LR2)
• Optical interfacespecifications—see “10-Gigabit Ethernet 10GBASEOptical Interface
Specifications” on page 34
• DWDM Tunable XFP transceivers:
• 10GBASE-ZR (model number: XFP-10G-CBAND-T50-ZR)
• Optical interfacespecifications—see “10-Gigabit Ethernet 10GBASEOptical Interface
Specifications” on page 34
• DWDM supported wavelengths—see “10-Gigabit Ethernet DWDM Transceiver
Wavelengths” on page 44
LEDs
Table 94: 10-Gigabit Ethernet LAN/WANPICwith XFP LEDs
DescriptionStateColorLabel
Port is not enabled.Off—Port LED, labeledPORT 0 throughPORT 3, one foreach port
Online with no alarms or failuresOn steadilyGreen
Online with alarms for remote failures.On steadilyYellow
Activewith a local alarm; router hasdetecteda failure.On steadilyRed
Alarms, Errors, and Events
Alarms are vendor-specific. Some transceiver vendors might not support every alarm.
• Input laser power
• Input loss of lock
• Input loss of signal
• Input Rx path
• Output A/D data not ready
• Output CDR (clock data recovery)
• Output laser bias current
• Output laser power
• Output laser safety
• Output Tx path
• Module temperature
• Module MOD_NR (module not ready)
149Copyright © 2017, Juniper Networks, Inc.
Chapter 9: 10-Gigabit Ethernet PIC Descriptions
• Module P_DOWN (module down)
• Module unplugged or down
• Wire unplugged or down
RelatedDocumentation
• T4000 PIC Description
• T4000 PICs Supported on page 3
Copyright © 2017, Juniper Networks, Inc.150
T4000 Core Router Interface Module Reference
CHAPTER 10
40-Gigabit Ethernet PIC Descriptions
• 40-Gigabit Ethernet PIC with CFP (T4000 Router) on page 151
40-Gigabit Ethernet PIC with CFP (T4000 Router)
40 G
RX
TX
ONLINE/OFFLINE
STATUS
g006069
• Software Release on page 151
• Hardware Features on page 152
• Software Features on page 152
• Cables and Connectors on page 153
• LEDs on page 153
• Alarms, Errors, and Events on page 153
Software Release
Junos OS Release 13.2
151Copyright © 2017, Juniper Networks, Inc.
For information on which FPCs support this PIC, see “T4000 PIC/FPC Compatibility” on
page 8.
Hardware Features
• One 40-Gigabit Ethernet port
• Power requirement: 1.46 A@–48 V (70.0W)
• Model number: PD-1XLE-CFP
• Maximum transmission units (MTUs) up to 9192 bytes
Software Features
Table 95: Software Features Supported
T4000 First Supported JunosOS ReleaseSoftware Feature
13.2R1Media Access Control (MAC) accounting
NOTE: MACaccountingon thisPIC is not supportedwhenaggregatedEthernet is configured.
13.2R1Source and destination MAC address filtering
13.2R1Ethernet OAM 802.3ah (remote loopback is not supported for this PIC)
13.2R1Layer 2 filtering and accounting based on Layer 2 headers
13.2R1Multiple tag protocol identifiers (TPIDs) used for filtering and counting
13.2R1Flexible virtual LAN (VLAN) tagging
13.2R1Channels defined by two stacked VLAN tags
13.2R1Layer 2 protocols:
• Flexible Ethernet service
• Ethernet circuit cross-connect (CCC)
• Ethernet translational cross-connect (TCC)
• Ethernet virtual private LAN service (VPLS)
• VLAN CCC
• Extended VLAN TCC
• VLAN VPLS
13.2R1Layer 3 protocols:
• IPV4
• IPV6
• MPLS
13.2R1Optical control features (vendor dependent)
Copyright © 2017, Juniper Networks, Inc.152
T4000 Core Router Interface Module Reference
Table 95: Software Features Supported (continued)
T4000 First Supported JunosOS ReleaseSoftware Feature
13.2R1IEEE 802.3ad Link Aggregation
13.2R1Graceful Routing Engine switchover (GRES)
Cables and Connectors
• Duplex SC/PC connector (RX and TX)
• 40-Gigabit Ethernet CFP transceiver: 40GBASE-LR4 (model number:
CFP-40GBASE-LR4)
• Optical interfacespecifications—see“40-GigabitEthernet40GBASE-ROptical Interface
Specifications” on page 46
LEDs
Table 96: 40-Gigabit Ethernet PIC with CFP LEDs
DescriptionStateColorLabel
PIC is not enabled.Off—STATUS
Online with no alarms or failures.On steadilyGreen
PIC is initializing.On steadilyYellow
PIC has a remote or local fault.On steadilyRed
Port might be on, but there is a local or remote fault.Off—Port LED Rx
Port is receiving data.On steadilyGreen
Port might be on, but there is a local fault.Off—Port LED Tx
Port is transmitting data.On steadilyGreen
Alarms, Errors, and Events
• Alarm indication signal (AIS)
• Laser bias current high/low alarms and warnings
• Laser Rx power high/low alarms and warnings
• Module not ready alarm
• Module power down alarm
• Module temperature high/low alarms and warnings
153Copyright © 2017, Juniper Networks, Inc.
Chapter 10: 40-Gigabit Ethernet PIC Descriptions
• Rx CDR loss of lock alarm
• Rx loss of signal alarm
• Rx not ready alarm
• Tx CDR loss of lock alarm
• Tx data not ready alarm
• Tx laser fault alarm
• Tx not ready alarm
RelatedDocumentation
• T4000 PIC Description
• T4000 PIC/FPC Compatibility on page 8
• T4000 PICs Supported on page 3
Copyright © 2017, Juniper Networks, Inc.154
T4000 Core Router Interface Module Reference
CHAPTER 11
100-Gigabit Ethernet PIC Descriptions
• 100-Gigabit Ethernet PIC with CFP (T4000 Router) on page 155
100-Gigabit Ethernet PIC with CFP (T4000 Router)
Figure 13: Type 5 100-Gigabit Ethernet PIC
g006291
• Software Release on page 155
• Hardware Features on page 156
• Software Features on page 156
• Cables and Connectors on page 159
• LEDs on page 160
• Alarms, Errors, and Events on page 161
Software Release
• Junos OS Release 12.1R1 and later (Type 5)
• Junos OS Release 12.1R2 and later (Type 4)
155Copyright © 2017, Juniper Networks, Inc.
NOTE: The Type 4 100-Gigabit Ethernet PIC is available only packaged inan assembly with the T1600-FPC4-ES FPC.
For information on which FPCs support these PICs, see “T4000 PIC/FPC Compatibility”
on page 8.
Hardware Features
Type 5 PIC
• One 100-Gigabit Ethernet port
• Power requirements with LR4 transceiver: 1.19 A@48 V (57W)
• Model number: PF-1CGE-CFP
Type 4 PIC
• One 100-Gigabit Ethernet port
• Power requirements for PD-1CE-CFP-FPC4 (PIC and FPC): 9.48 A@48 V (455W)
• Model number: PD-1CE-CFP-FPC4
• PIC 0 and PIC 1 are connected by a bridge board.
• There are two physical interfaces when the 100-Gigabit Ethernet PIC is online. Each
physical interface representsoneof two internal50-GigabitEthernetPacketForwarding
Engines (PFEs) in the FPC. PFE0 is physical interface 0, PFE1 is physical interface 1.
The following example shows the CLI representation of the physical interface. The
interface type is et, fpc is the FPC slot number, the PIC slot is always 0, and the PFEs
are 0:0 for PFE0 and 0:1 for PFE1.
• et-fpc/0/0:0
• et-fpc/0/0:1
• Youmust also configure two logical interfaces under each physical interface. The
following CLI example shows the logical interfaces.
• et-fpc/0/0:0.0 and et-fpc/0/0:0.1
• et-fpc/0/0:1.0 and et-fpc/0/0:1.1
• Support for MTUs up to 9192 bytes
Software Features
Table 97: Software Features Supported on Type 5 PIC
T4000 First SupportedJunos OS ReleaseSoftware Feature
12.1R1Interface hold timer
Copyright © 2017, Juniper Networks, Inc.156
T4000 Core Router Interface Module Reference
Table 97: Software Features Supported on Type 5 PIC (continued)
T4000 First SupportedJunos OS ReleaseSoftware Feature
12.1R1Support for 100 Gigabit Ethernet MIBs
12.1R1Graceful Routing Engine switchover (GRES)
12.1R1Layer 3 protocols:
• IPV4
• IPV6
• MPLS
12.1R1MACfiltering, accounting, policing, and learning for sourcemediaaccesscontrol (MAC)on logicalinterfaces
12.1R1Layer 2 protocols:
• Flexible Ethernet service
• Ethernet circuit cross-connect (CCC)
• Ethernet translational cross-connect (TCC)
• Ethernet virtual private LAN service (VPLS)
• VLAN CCC
• Extended VLAN TCC
• VLAN VPLS
12.1R1Flexible encapsulation
12.1R1Single, stacked, and flexible VLAN tagging modes
12.1R1Native VLAN configuration to allow untagged frames to be received on the tagged interfaces
12.1R1IEEE 802.3ad Link Aggregation (on single chassis)
12.1R1Defining theVLANrewriteoperation tobeapplied to the incomingandoutgoing frameson logicalinterfaces on this PIC
NOTE: Only the Tag Protocol Identifier (TPID) 0x8100 is supported.
12.1R1Behavior aggregate (BA) classification (IPv4 DSCP, IPv6 DSCP, Inet precedence, IEEE 802.1P,IEEE 802.1AD, MPLS EXP) and fixed classification.
12.1R1Type5 (model numberPF-1CGE-CFP) interoperabilitywith the 100-Gigabit EthernetPIC (modelnumber PD-1CE-CFP-FOC4) supported in Junos OS Release 12.1R2 and later
157Copyright © 2017, Juniper Networks, Inc.
Chapter 11: 100-Gigabit Ethernet PIC Descriptions
Table 98: Software Features Supported on Type 4 PIC
T4000FirstSupportedJunos OS ReleaseSoftware Feature
12.1R2Media Access Control (MAC) accounting
NOTE: MAC accounting on this PIC is not supported when aggregated Ethernet is configured.
12.1R2Source and destination MAC address filtering
12.1R2Ethernet OAM 802.3ah (remote loopback is not supported for this PIC)
12.1R2Layer 2 filtering and accounting based on Layer 2 headers
12.1R2Multiple tag protocol identifiers (TPIDs) used for filtering and counting
12.1R2Flexible virtual LAN (VLAN) tagging
12.1R2Channels defined by two stacked VLAN tags
12.1R2Layer 2 protocols:
• Flexible Ethernet service
• Ethernet circuit cross-connect (CCC)
• Ethernet translational cross-connect (TCC)
• Ethernet virtual private LAN service (VPLS)
• VLAN CCC
• Extended VLAN TCC
• VLAN VPLS
12.1R2Layer 3 protocols:
• IPV4
• IPV6
• MPLS
12.1R2Optical control features (vendor dependent)
12.1R2IEEE 802.3ad Link Aggregation
NOTE: Aggregated Ethernet must be configured on this PIC to support interoperability with100-Gigabit Ethernet PIC (model number PF-1CGE-CFP) or the 100-Gigabit Ethernet MIC (modelnumber MIC3-3D-1X100GE-CFP) .
12.1R2Graceful Routing Engine switchover (GRES)
Copyright © 2017, Juniper Networks, Inc.158
T4000 Core Router Interface Module Reference
Table 98: Software Features Supported on Type 4 PIC (continued)
T4000FirstSupportedJunos OS ReleaseSoftware Feature
12.1R2Interoperability for Type 4 (model number: PD-1CE-CFP-FPC4)
• VLAN-steering provides interoperability with 100-Gigabit Ethernet interfaces fromother vendors
• Interoperability between 100-Gigabit Ethernet PIC (model number PD-1CE-CFP-FPC4) and the100-Gigabit Ethernet PIC (model number PF-1CGE-CFP) supported in Junos OS Release 12.1R2and later
• Interoperability between 100-Gigabit Ethernet PIC (model number PD-1CE-CFP-FPC4) and the100-GigabitEthernetMIC(modelnumberMIC3-3D-1X100GE-CFP)supported in JunosOSRelease12.1R2
Cables and Connectors
• You can install any 100-Gigabit Ethernet CFP transceiver supported by the PIC.
• 100GBASE-LR4 (model number: CFP-100GBASE-LR4)
• Duplex SC connector (RX and TX)
• Junos OS Release 12.1 and later
• 100GBASE-LR4 (model number: CFP-GEN2-100GBASE-LR4 and part number:
740-047682)
• Duplex LC connector (RX and TX)
• Junos OS Release 12.3R5, 13.2R3, 13.3R1, and later releases
NOTE: The “GEN2” optics have been redesigned with newer versions ofinternal components for reduced power consumption.
• 100GBASE-ER4 (model number: CFP-100GBASE-ER4)
• Duplex LC connector (RX and TX)
• Junos OS Release 12.3 and later
• 100GBASE-ER4 (model number: CFP-GEN2-CGE-ER4 and part number:
740-049763)
• Duplex LC connector (RX and TX)
• Junos OS Release 12.3R5, 13.2R3, 13.3R1, and later releases
NOTE: The “GEN2” optics have been redesigned with newer versions ofinternal components for reduced power consumption.
• 100GBASE-SR10 (model number: CFP-100GBASE-SR10)
159Copyright © 2017, Juniper Networks, Inc.
Chapter 11: 100-Gigabit Ethernet PIC Descriptions
• 24-fiber MPO
• Junos OS Release 12.3 and later
• Optical interface specifications—see “100-Gigabit Ethernet 100GBASE-R Optical
Interface Specifications” on page 49
LEDs
Table 99: Type 5 LEDs
DescriptionStateColorLabel
PIC is powered down and offline.Off—STATUS
PIC is online with all voltages in range.On steadilyGreen
PIC is initializing.On steadilyYellow
PIC has an error or failure.On steadilyRed
Port is off.Off—Link STATUSLED
Port detecting failure with alarms.On steadilyRed
Port is online and link is up.On steadilyGreen
No link activity.Off—LinkACTIVITYLED
Indicates link activity for the port.FlashingGreen
Table 100: Type 4 PIC LEDs
DescriptionStateColorLabel
PIC is powered down and offline.Off—Two tricolorSTATUS LEDs(P1C0andP1C1) PIC is online with no alarms or failures.On steadilyGreen
PIC is initializing.On steadilyYellow
PIC has a remote or local fault.On steadilyRed
Port might be on, but there is a local or remote fault.Off—Rx LED (P1C 1)
Port is receiving data.On steadilyGreen
Port might be on, but there is a local fault.Off—Tx LED (P1C 1)
Port is transmitting data.On steadilyGreen
Copyright © 2017, Juniper Networks, Inc.160
T4000 Core Router Interface Module Reference
Alarms, Errors, and Events
Alarms are vendor-specific. Some transceiver vendors might not support every alarm.
• Input laser power
• Input loss of lock
• Input loss of signal
• Input Rx path
• Output A/D data not ready
• Output CDR (clock data recovery)
• Output laser bias current
• Output laser power
• Output laser safety
• Output Tx path
• Module temperature
• Module MOD_NR (module not ready)
• Module P_DOWN (module down)
• Module unplugged or down
• Wire unplugged or down
RelatedDocumentation
• T4000 PIC Description
• T4000 PICs Supported on page 3
161Copyright © 2017, Juniper Networks, Inc.
Chapter 11: 100-Gigabit Ethernet PIC Descriptions
Copyright © 2017, Juniper Networks, Inc.162
T4000 Core Router Interface Module Reference
CHAPTER 12
Services PIC Descriptions
• MultiServices PICs (T4000 Router) on page 163
• Tunnel Services PICs (T4000 Router) on page 167
MultiServices PICs (T4000 Router)
Figure 14: MultiServices 400 PIC
163Copyright © 2017, Juniper Networks, Inc.
Figure 15: MultiServices 500 PIC
• Software Release on page 164
• Hardware Features on page 164
• Software Features on page 165
• LEDs on page 166
Software Release
• MultiServices 400: Junos OS Release 12.2R1 and later (Type 2)
• MultiServices 500: Junos OS Release 12.1R2 and later (Type 3)
For information on which FPCs support this PIC, see “T4000 PIC/FPC Compatibility” on
page 8.
Hardware Features
• Individual licenses must be purchased for services.
• Power requirement:
• Multiservices 400: 0.69 A@ 48 V (33W)
• Multiservices 500: 0.83 A@ 48 V (40W)
• Model number for Multiservices 400 PIC: PB-MS-400-2
• Model number for Multiservices 500 PIC: PB-MS-500-3
• Multiservices 400: up to 3.2 million flows
• Multiservices 500: up to 3.2 million flows
Copyright © 2017, Juniper Networks, Inc.164
T4000 Core Router Interface Module Reference
Software Features
• Support for up to 2000 service sets
• Support for MTUs up to 9192 bytes for Gigabit Ethernet and SONET interfaces
Depending on your Junos OS Release and individual licenses, software features for this
PIC can include the features listed in Table 101 on page 165. For more information about
the software features available for services PICs, see the Junos OS Services Interfaces
Library for Routing Devices.
Table 101: MultiServices PICs Software Features Supported on the T4000 Router
––GRE Key
––GRE dont-fragment
––Stateful firewall with packet inspection: detects SYNattacks, ICMPandUDP floods, andping-of-deathattacks
––Network Address Translation (NAT) for IP addresses
––Port Address Translation (PAT) for port numbers
––IP Security (IPSec) encryption
12.1R2–Flow aggregation
12.1R2–Active flowmonitoring exports cflowd version 5 andversion 8 records
12.1R2–Active flowmonitoring exports flowmonitoring version 9records, based on RFC 3954
–12.2Passive flowmonitoring
–12.2Passive flow collection
––Flow-tap
–12.2Dynamic flow capture
––Real-time performancemonitoring
––Link Services
12.1R2–Traffic sampling
165Copyright © 2017, Juniper Networks, Inc.
Chapter 12: Services PIC Descriptions
Table 101: MultiServices PICs Software Features Supported on the T4000 Router (continued)
––Tunnel services:
• IP-IP unicast tunneling
• GRE unicast tunneling—Supports GRE fragmentation
• Protocol Independent Multicast (PIM) sparse modeunicast tunneling
––Virtual tunnel interface for Layer 3 VPNs
––Layer 2 Tunneling Protocol (L2TP)
––Voice services:
• Compressed Real-Time Transport Protocol (CRTP)
––Encapsulations:
• Multilink Frame Relay (MLFR)
• Multilink Point-to-Point Protocol (MLPP)
LEDs
Table 102: MultiServices PIC LEDs
DescriptionStateColorLabel
PIC is offline and it is safe to remove it from the chassis.Off—PIC STATUSLED, onetricolor PIC is operating normally.On steadilyGreen
PIC is initializing.On steadilyYellow
PIC has an error or failure and no further harm can bedone by removing it from the chassis.
On steadilyRed
Service is not running.Off—ApplicationAPP STATUSLED, onebicolor
Service is running under acceptable load.On steadilyGreen
Service is overloaded.On steadilyYellow
RelatedDocumentation
T4000 PIC Description•
• T4000 PICs Supported on page 3
Copyright © 2017, Juniper Networks, Inc.166
T4000 Core Router Interface Module Reference
Tunnel Services PICs (T4000 Router)
• Software Release on page 167
• Hardware Features on page 167
• Software Features on page 167
• LEDs on page 168
Software Release
• Junos OS Release 12.1R2 and later (Type 1)
• Junos OS Release 12.2R2 and later (Type 2)
• Junos OS Release 12.1R2 and later (Type 3)
For information on which FPCs support this PIC, see “T4000 PIC/FPC Compatibility” on
page 8.
Hardware Features
• Power requirement: 0.07 A@ 48 V (3.4W)
• Model number for Type 1 Tunnel Services PIC: PB-TUNNEL1
• Model number for Type 2 Tunnel Services PIC: PB-TUNNEL
• Model number for Type 3 Tunnel Services PIC: PC-TUNNEL
• Loopback function that encapsulates and de-encapsulates packets
• OC12/STM4 tunneling bandwidth on Type 1 FPC
• OC48/STM16 tunneling bandwidth on Type 2 FPC
• OC192/STM64 tunneling bandwidth on Type 3 FPC
Software Features
For a list of the software features available for services PICs, see the Junos Services
Interfaces Configuration Release.
167Copyright © 2017, Juniper Networks, Inc.
Chapter 12: Services PIC Descriptions
• IP-IP unicast tunneling
• GRE unicast tunneling
• PIM sparse mode unicast tunneling
LEDs
Table 103: Tunnel Services PIC LEDs
DescriptionStateColorLabel
Not enabled.Off—One STATUSLED, tricolor
Online with no alarms or failures.On steadilyGreen
Online with alarms for remote failures.On steadilyYellow
Active with a local alarm; router has detected a failure.On steadilyRed
RelatedDocumentation
• T4000 PIC Description
• T4000 PICs Supported on page 3
Copyright © 2017, Juniper Networks, Inc.168
T4000 Core Router Interface Module Reference
CHAPTER 13
SONET/SDH PIC Descriptions
• SONET/SDHOC3/STM1 (Multi-Rate) PICs with SFP (T4000 Router) on page 169
• SONET/SDHOC12/STM4 (Multi-Rate) PICs with SFP (T4000 Router) on page 174
• SONET/SDHOC48c/STM16 PIC with SFP (T4000 Router) on page 178
• SONET/SDHOC48/STM16Enhanced IQ(IQE)PICwithSFP(T4000Router)onpage182
• SONET/SDHOC48/STM16 (Multi-Rate) PIC with SFP (T4000 Router) on page 186
• SONET/SDHOC192/STM64 PICs with XFP (T4000 Router) on page 190
• SONET/SDHOC768c/STM256 PIC (T4000 Router) on page 195
SONET/SDHOC3/STM1 (Multi-Rate) PICs with SFP (T4000 Router)
Figure 17: SONET/SDHOC3/STM1(Multi-Rate) PIC (Type 2)
PO
RT
3
Figure 16: SONET/SDHOC3/STM1(Multi-Rate) PIC (Type 1)
• Software Release on page 170
• Hardware Features on page 170
• Software Features on page 170
• Cables and Connectors on page 171
169Copyright © 2017, Juniper Networks, Inc.
• LEDs on page 172
• Alarms, Errors, and Events on page 172
Software Release
• 4-port: Junos OS Release 12.1R2 and later (Type 1)
• 4-port: Junos OS Release 12.2R2 and later (Type 2)
For information on which FPCs support this PIC, see “T4000 PIC/FPC Compatibility” on
page 8.
Hardware Features
• Rate-selectable using one of the following rates:
• 1-port OC12/STM4
• 1-port OC12c/STM4c
• 4-port OC3c/STM1c
• Power requirement: 0.40 A@ 48 V (19W)
• Model number for SONET/SDHOC3/STM1 (Multi-Rate) PIC (Type_1):
PB-40C3-1OC12-SON-SFP
• Model number for SONET/SDHOC3/STM1 (Multi-Rate) PIC (Type_2):
PB-4OC3-1OC12-SON2-SFP
• Multiplexing and demultiplexing
• Rate policing on input
• Rate shaping on output
• Packet buffering, Layer 2 parsing
Software Features
Table 104: Software Features Supported
T4000 First SupportedJunos OS Release (Type 2PIC)
T4000 First SupportedJunos OS Release (Type 1PIC)Software Feature
12.2R212.1R2Optical diagnostics and related alarms
12.2R212.1R2Per-port SONET/SDH framing
12.2R212.1R2IEEE 802.3ad Link Aggregation
12.2R212.1R2Alarm and event counting and detection
12.2R212.1R2Dual-router automatic protection switching (APS)
12.2R212.1R2Multiprotocol Label Switching (MPLS) fast reroute
Copyright © 2017, Juniper Networks, Inc.170
T4000 Core Router Interface Module Reference
Table 104: Software Features Supported (continued)
T4000 First SupportedJunos OS Release (Type 2PIC)
T4000 First SupportedJunos OS Release (Type 1PIC)Software Feature
12.2R212.1R2Encapsulations:
• Circuit cross-connect (CCC)
• Translational cross-connect (TCC)
• Frame Relay
• High-Level Data Link Control (HDLC)
• Point-to-Point Protocol (PPP)
Cables and Connectors
You can install any transceiver supported by the PIC. For information about installing
and removing transceivers.
• Duplex LC connector (Rx and Tx)
• SONET/SDHOC3/STM1 small form-factor pluggable (SFP) transceivers:
• Multimode (model number: SFP-OC3-SR)
• Intermediate reach (IR-1) (model number: SFP-OC3-IR)
• Long reach (LR-1) (model number: SFP-OC3-LR)
Optical interface specifications—see “SONET/SDHOC3/STM1 Optical Interface
Specifications” on page 53
• SONET/SDHOC12/STM4 small form-factor pluggable (SFP) transceivers:
• Short reach (model number: SFP-OC12-SR)
• Intermediate reach (IR-1) (model number: SFP-OC312-IR)
• Long reach (LR-1) (model number: SFP-OC12-LR)
Optical interface specifications—see “SONET/SDHOC12/STM4 Optical Interface
Specifications” on page 55
NOTE: To extend the life of the laser, when a PIC is not being actively usedwith any valid links, take the PIC offline until you are ready to establish a linkto another device. For information about taking a PIC offline, see the request
chassis pic offline command in request chassis pic.
171Copyright © 2017, Juniper Networks, Inc.
Chapter 13: SONET/SDH PIC Descriptions
LEDs
Table 105: SONET/SDHOC3/STM1 (Multi-Rate) PICwith SFP LEDs
DescriptionStateColorLabel
Not enabled.Off—One tricolorper port
Online with no alarms or failures.On steadilyGreen
Online with alarms for remote failures.On steadilyYellow
Active with a local alarm; router has detected a failure.On steadilyRed
Alarms, Errors, and Events
• SONET alarms:
• Alarm indication signal—line (AIS-L)
• Alarm indication signal—path (AIS-P)
• Bit error rate—signal degrade (BERR-SD)
• Bit error rate—signal fail (BERR-SF)
• Bit interleaved parity (BIP) error B1, B2, B3
• Far-end bit error: remote error indication—line (REI-L), far-end line coding violations
(CV-LFE)
• Far-endbit error: remoteerror indication—path(REI-P), far-endpathcodingviolations
(CV-PFE)
• Loss of frame (LOF)
• Loss of pointer (LOP-P)
• Loss of signal (LOS)
• Payload label mismatch (PLM-P)
• Payload unequipped (unequipped STS at path level) (UNEQ-P)
• Remote defect indication—line (RDI-L)
• Remote defect indication—path (RDI-P)
• SDH alarms:
• Administrative unit alarm indication signal (AU-AIS)
• Bit error rate signal degrade (BERR-SD)
• Bit error rate signal fail (BERR-SF)
• Bit interleaved parity (BIP) error B1, B2, B3
• Higher order path—payload label mismatch (HP-PLM)
Copyright © 2017, Juniper Networks, Inc.172
T4000 Core Router Interface Module Reference
• Higher order path—loss of pointer (HP-LOP)
• Higher order path—remote defect indication (HP-RDI)
• Higher order path—unequipped (HP-UNEQ)
• Loss of frame (LOF)
• Loss of signal (LOS)
• Multiplex section—alarm indication signal (MS-AIS)
• Multiplex section—remote defect indication (MS-RDI)
• Multiplex section—remote error indication (MS-REI)
• Error detection:
• Errored seconds (ES-S, ES-L, ES-P)
• Far-end errored seconds (ES-LFE, ES-PFE)
• Far-end severely errored seconds (SES-LFE, SES-PFE)
• Far-end unavailable seconds (UAS-LFE, UAS-PFE)
• Severely errored framing (SEF)
• Severely errored framing seconds (SEFS-S)
• Severely errored seconds (SES-S, SES-L, SES-P)
• Unavailable seconds (UAS-L, UAS-P)
RelatedDocumentation
T4000 PIC Description•
• T4000 PICs Supported on page 3
173Copyright © 2017, Juniper Networks, Inc.
Chapter 13: SONET/SDH PIC Descriptions
SONET/SDHOC12/STM4 (Multi-Rate) PICs with SFP (T4000 Router)
Figure 19: 4-Port SONET/SDHOC12/STM4(Multi-Rate) PIC
Figure 18: 1-Port SONET/SDHOC12/STM4(Multi-Rate) PIC
• Software Release on page 174
• Hardware Features on page 174
• Software Features on page 175
• Cables and Connectors on page 176
• LEDs on page 176
• Alarms, Errors, and Events on page 177
Software Release
• Junos OS Release 12.1R2 ander later
• Junos OS Release 12.2R2 and later (Type 2)
For information on which FPCs support this PIC, see “T4000 PIC/FPC Compatibility” on
page 8.
Hardware Features
• 1-port: Rate-selectable using one of the following rates:
• 1-port OC3/STM1
• 1-port OC12/STM4
• 1-port OC12c/STM4c
• 4-port: Rate-selectable using one of the following rates:
Copyright © 2017, Juniper Networks, Inc.174
T4000 Core Router Interface Module Reference
• 1-port OC12/STM4
• 1-port OC48/STM16
• 1-port OC48c/STM16c
• 4-port OC3c/STM1c
• 4-port OC12c/STM4c
• Power requirement:
• 1-port: 0.20 A@ 48 V (9.5W)
• 4-port: 0.40 A@ 48 V (19W)
• Model number for 1-Port SONET/SDHOC12/STM4 (Multi-Rate) PIC:
PB-1OC12-SON-SFP
• Model number for 4-Port SONET/SDHOC12/STM4 (Multi-Rate) PIC:
PB-4OC3-4OC12-SON-SFP
• Multiplexing and demultiplexing
• Rate policing on input
• Rate shaping on output
• Packet buffering, Layer 2 parsing
Software Features
Table 106: Software Features Supported
T4000 First SupportedJunosOSRelease for4-portPIC
T4000 First SupportedJunosOSRelease for 1-portPICSoftware Feature
12.2R212.1R2Optical diagnostics and related alarms
12.2R212.1R2Per-port SONET/SDH framing
12.2R212.1R2Link aggregation
12.2R212.1R2Alarm and event counting and detection
12.2R212.1R2Dual-router automatic protection switching (APS)
12.2R212.1R2Multiprotocol Label Switching (MPLS) fast reroute
12.2R212.1R2Encapsulations:
• Circuit cross-connect (CCC)
• Translational cross-connect (TCC)
• Frame Relay
• High-Level Data Link Control (HDLC)
• Point-to-Point Protocol (PPP)
175Copyright © 2017, Juniper Networks, Inc.
Chapter 13: SONET/SDH PIC Descriptions
Cables and Connectors
You can install any transceiver supported by the PIC. For information about installing
and removing transceivers.
• Duplex LC/PC connector (Rx and Tx)
• SONET/SDHOC3/STM1 small form-factor pluggable (SFP) transceivers:
• Multimode (model number: SFP-OC3-SR)
• Intermediate reach (IR-1) (model number: SFP-OC3-IR)
• Long reach (LR-1) (model number: SFP-OC3-LR)
Optical interface specifications—see “SONET/SDHOC3/STM1 Optical Interface
Specifications” on page 53
• SONET/SDHOC12/STM4 small form-factor pluggable (SFP) transceivers:
• Short reach (model number: SFP-OC12-SR)
• Intermediate reach (IR-1) (model number: SFP-OC312-IR)
• Long reach (LR-1) (model number: SFP-OC12-LR)
Optical interface specifications—see “SONET/SDHOC12/STM4 Optical Interface
Specifications” on page 55
NOTE: To extend the life of the laser, when a PIC is not being actively usedwith any valid links, take the PIC offline until you are ready to establish a linkto another device. For information about taking a PIC offline, see the request
chassis pic offline command in request chassis pic.
LEDs
Table 107: SONET/SDHOC12/STM4 (Multi-Rate) PICs with SFP LEDs
DescriptionStateColorLabel
Not enabled.Off—One tricolorper port
Online with no alarms or failures.On steadilyGreen
Online with alarms for remote failures.On steadilyYellow
Active with a local alarm; router has detected a failure.On steadilyRed
Copyright © 2017, Juniper Networks, Inc.176
T4000 Core Router Interface Module Reference
Alarms, Errors, and Events
• SONET alarms:
• Alarm indication signal—line (AIS-L)
• Alarm indication signal—path (AIS-P)
• Bit error rate—signal degrade (BERR-SD)
• Bit error rate—signal fail (BERR-SF)
• Bit interleaved parity (BIP) error B1, B2, B3
• Far-end bit error: remote error indication—line (REI-L), far-end line coding violations
(CV-LFE)
• Far-endbit error: remoteerror indication—path(REI-P), far-endpathcodingviolations
(CV-PFE)
• Loss of frame (LOF)
• Loss of pointer (LOP-P)
• Loss of signal (LOS)
• Payload label mismatch (PLM-P)
• Payload unequipped (unequipped STS at path level) (UNEQ-P)
• Remote defect indication—line (RDI-L)
• Remote defect indication—path (RDI-P)
• SDH alarms:
• Administrative unit alarm indication signal (AU-AIS)
• Bit error rate signal degrade (BERR-SD)
• Bit error rate signal fail (BERR-SF)
• Bit interleaved parity (BIP) error B1, B2, B3
• Higher order path—payload label mismatch (HP-PLM)
• Higher order path—loss of pointer (HP-LOP)
• Higher order path—remote defect indication (HP-RDI)
• Higher order path—unequipped (HP-UNEQ)
• Loss of frame (LOF)
• Loss of signal (LOS)
• Multiplex section—alarm indication signal (MS-AIS)
• Multiplex section—remote defect indication (MS-RDI)
• Multiplex section—remote error indication (MS-REI)
177Copyright © 2017, Juniper Networks, Inc.
Chapter 13: SONET/SDH PIC Descriptions
• Error detection:
• Errored seconds (ES-S, ES-L, ES-P)
• Far-end errored seconds (ES-LFE, ES-PFE)
• Far-end severely errored seconds (SES-LFE, SES-PFE)
• Far-end unavailable seconds (UAS-LFE, UAS-PFE)
• Severely errored framing (SEF)
• Severely errored framing seconds (SEFS-S)
• Severely errored seconds (SES-S, SES-L, SES-P)
• Unavailable seconds (UAS-L, UAS-P)
RelatedDocumentation
T4000 PIC Description•
• T4000 PICs Supported on page 3
SONET/SDHOC48c/STM16 PICwith SFP (T4000 Router)
• Software Release on page 178
• Hardware Features on page 179
• Software Features on page 179
• Cables and Connectors on page 179
• LEDs on page 180
• Alarms, Errors, and Events on page 180
Software Release
Junos OS Release 12.1R2 and later
Copyright © 2017, Juniper Networks, Inc.178
T4000 Core Router Interface Module Reference
For information on which FPCs support this PIC, see “T4000 PIC/FPC Compatibility” on
page 8.
Hardware Features
• Four OC48 ports
• Power requirement: 0.46 A@ 48 V (22.1 W)
• Model number: PC-4OC48-SON-SFP
• Multiplexing and demultiplexing on the 1-port PIC
• Rate policing on input
• Rate shaping on output
• Packet buffering, Layer 2 parsing
Software Features
Table 108: Software Features Supported
T4000 First Supported Junos OSReleaseSoftware Feature
12.1R2Optical diagnostics and related alarms
12.1R2Configuration of SONET or SDH framing on a per-port basis
12.1R2SONET/SDH framing
12.1R2IEEE 802.3ad Link Aggregation
12.1R2Alarm and event counting and detection
12.1R2Dual-router automatic protection switching (APS)
12.1R2Multiprotocol Label Switching (MPLS) fast reroute
12.1R2Layer 2 protocols:
• Circuit cross-connect (CCC)
• Translational cross-connect (TCC)
• Frame Relay
• High-Level Data Link Control (HDLC)
• Point-to-Point Protocol (PPP)
Cables and Connectors
You can install any transceiver supported by the PIC. For information about installing
and removing.
• Duplex LC connector (Rx and Tx)
179Copyright © 2017, Juniper Networks, Inc.
Chapter 13: SONET/SDH PIC Descriptions
• SONET/SDHOC48/STM16 fiber-optic SFP transceivers:
• Short reach (SR-1) (model number: SFP-1OC48-SR)
• Intermediate reach (IR-1) (model number: SFP-1OC48-IR)
• Long reach (LR-1) (model number: SFP-1OC48-LR)
Optical interface specifications—see “SONET/SDHOC48/STM16 Optical Interface
Specifications” on page 57
NOTE: To extend the life of the laser, when a PIC is not being actively usedwith any valid links, take the PIC offline until you are ready to establish a linkto another device. For information about taking a PIC offline, see the request
chassis pic offline command in request chassis pic.
LEDs
Table 109: SONET/SDHOC48c/STM16 PICwith SFP LEDs
DescriptionStateColorLabel
Not enabledOff—STATUS LED,one tricolor perport Online with no alarms or failuresOn steadilyGreen
Online with alarms for remote failuresOn steadilyYellow
Active with a local alarm; router has detected a failureOn steadilyRed
Alarms, Errors, and Events
• SONET alarms:
• Alarm indication signal—line (AIS-L)
• Alarm indication signal—path (AIS-P)
• Bit error rate—signal degrade (BERR-SD)
• Bit error rate—signal fail (BERR-SF)
• Bit interleaved parity (BIP) error B1, B2, B3
• Far-end bit error: remote error indication—line (REI-L), far-end line coding violations
(CV-LFE)
• Far-endbit error: remoteerror indication—path(REI-P), far-endpathcodingviolations
(CV-PFE)
• Loss of frame (LOF)
• Loss of pointer (LOP-P)
• Loss of signal (LOS)
Copyright © 2017, Juniper Networks, Inc.180
T4000 Core Router Interface Module Reference
• Payload label mismatch (PLM-P)
• Payload unequipped (unequipped STS at path level) (UNEQ-P)
• Remote defect indication—line (RDI-L)
• Remote defect indication—path (RDI-P)
• SDH alarms:
• Administrative unit alarm indication signal (AU-AIS)
• Bit error rate signal degrade (BERR-SD)
• Bit error rate signal fail (BERR-SF)
• Bit interleaved parity (BIP) error B1, B2, B3
• Higher order path—payload label mismatch (HP-PLM)
• Higher order path—loss of pointer (HP-LOP)
• Higher order path—remote defect indication (HP-RDI)
• Higher order path—unequipped (HP-UNEQ)
• Loss of frame (LOF)
• Loss of signal (LOS)
• Multiplex section—alarm indication signal (MS-AIS)
• Multiplex section—remote defect indication (MS-RDI)
• Multiplex section—remote error indication (MS-REI)
• Error detection:
• Errored seconds (ES-S, ES-L, ES-P)
• Far-end errored seconds (ES-LFE, ES-PFE)
• Far-end severely errored seconds (SES-LFE, SES-PFE)
• Far-end unavailable seconds (UAS-LFE, UAS-PFE)
• Severely errored framing (SEF)
• Severely errored framing seconds (SEFS-S)
• Severely errored seconds (SES-S, SES-L, SES-P)
• Unavailable seconds (UAS-L, UAS-P)
RelatedDocumentation
T4000 PIC Description•
• T4000 PICs Supported on page 3
181Copyright © 2017, Juniper Networks, Inc.
Chapter 13: SONET/SDH PIC Descriptions
SONET/SDHOC48/STM16 Enhanced IQ (IQE) PICwith SFP (T4000 Router)
g006
030
• Software Release on page 182
• Hardware Features on page 182
• Software Features on page 183
• Cables and Connectors on page 183
• LEDs on page 184
• Alarms, Errors, and Events on page 184
Software Release
Junos OS Release 13.2 and later (Type 3)
For information on which FPCs support this PIC, see“T4000 PIC/FPC Compatibility” on
page 8.
Hardware Features
• Four OC48/STM16 ports
• Clear channel functionality
• SONET and SDH is configured on a per-port granularity
• Power requirement: 1.06 A@ 48 V (51W)
• Weight: 1.6 lb (0.725 kg)
• Model number: PC-4OC48-STM16-IQE-SFP
• Ports are numbered:
Copyright © 2017, Juniper Networks, Inc.182
T4000 Core Router Interface Module Reference
• Top row: 0 and 1 from left to right
• Bottom row: 2 and 3 from left to right
• Maximum transmission units (MTUs) of up to 9192 bytes
Software Features
Table 110: Software Features Supported
T4000 First SupportedJunos OS ReleaseSoftware Feature
13.2R1Quality of service (QoS) per channel: weighted round-robin (WRR), random early detection(RED), weighted random early detection (WRED)
13.2R1Fine-grainedegressqueuingper logical interface. See theClassofService FeatureGuide forRoutingDevices for more information about class-of-service features
13.2R1Packet buffering
13.2R1Local line and remote payload loopback testing
13.2R1Optical diagnostics andmonitoring
13.2R1Clocking options: internal or external/loopmode. EachOC48 transmitter port is configured eitherin internal or external mode. The default clocking option is internal mode.
13.2R1Encapsulations:
• Extended Frame Relay for circuit cross-connect (CCC) and translational cross-connect (TCC)
• Flexible Frame Relay
• Frame Relay
• Frame Relay for CCC
• Frame Relay for TCC
• Frame Relay port CCC
• High-Level Data Link Control (HDLC)
• HDLC framing for CCC
• HDLC framing for TCC
• MPLS CCC
• MPLS TCC
• Point-to-Point Protocol (PPP)
• PPP for CCC
• PPP for TCC
Cables and Connectors
You can install any transceiver supported by the PIC.
• Duplex LC connector (Rx and Tx)
• SONET/SDHOC48/STM16 small form-factor pluggable (SFP) transceivers:
183Copyright © 2017, Juniper Networks, Inc.
Chapter 13: SONET/SDH PIC Descriptions
• Short reach (SR-1) (model number: SFP-1OC48-SR)
• Intermediate reach (IR-1) (model number: SFP-1OC48-IR)
• Long reach (LR-1) (model number: SFP-1OC48-LR)
Optical interface specifications—see “SONET/SDHOC48/STM16 Optical Interface
Specifications” on page 57
NOTE: To extend the life of the laser, when a PIC is not being actively usedwith any valid links, take the PIC offline until you are ready to establish a linkto another device. For information about taking a PIC offline, see the request
chassis pic offline command in request chassis pic.
LEDs
Table 111: SONET/SDHOC48/STM16 Enhanced IQ (IQE) PICwith SFP LEDs
DescriptionStateColorLabel
PIC is offline and safe to remove from the router.Off—Ok LED, onetricolor
PIC is operating normally.On steadilyGreen
PIC is initializing.On steadilyYellow
PIC has an error or failure.On steadilyRed
Service is not running.Off—APP LED, onegreen per port
Green—Service is running under acceptable load.On steadilyGreen
Not enabled.Off—Port LEDs, onetricolorperport
Online with no alarms or failures.On steadilyGreen
Online with alarms for remote failures.On steadilyYellow
Active with a local alarm; router has detected a failure.On steadilyRed
Alarms, Errors, and Events
SONET alarms:
• Loss of light (LOL)
• Phase lock loop (PLL)
• Loss of frame (LOF)
• Loss of signal (LOS)
Copyright © 2017, Juniper Networks, Inc.184
T4000 Core Router Interface Module Reference
• Severely errored frame (SEF)
• Alarm indicator signal—line (AIS-L)
• Alarm indicator signal—path (AIS-P)
• Loss of pointer (LOP)
• Bit error rate—signal degrade (BERR-SD)
• Bit error rate—signal fail (BERR-SF)
• Remote defect indicator—line (RDI-L)
• Remote defect indicator—path (RDI-P)
• Remote error indicator (REI)
• Unequipped (UNEQ)
• Payload label mismatch—path (PLM-P)
SDH alarms:
• Loss of light (LOL)
• Phase lock loop (PLL)
• Loss of frame (LOF)
• Loss of signal (LOS)
• Severely errored frame (SEF)
• Multiplex-section alarm indicator signal (MS-AIS)
• H Path alarm indicator signal (HP-AIS)
• Loss of pointer (LOP)
• Bit error rate—signal degrade (BERR-SD)
• Bit error rate—signal fail (BERR-SF)
• Multiplex section—far end receive failure (MS-FERF)
• High order path—far end receive failure (HP-FERF)
• Remote error indicator (REI)
• Unequipped (UNEQ)
• High order path—payload label mismatch - Path (HP-PLM)
Optical diagnostics related alarms:
NOTE: Transceivers from some vendors do not support these fields.
• Temperature high/low alarms and warnings
• Supply voltage high/low alarms and warnings
185Copyright © 2017, Juniper Networks, Inc.
Chapter 13: SONET/SDH PIC Descriptions
• Tx bias current high/low alarms and warnings
• Tx output power high/low alarms and warnings
• Rx received power high/low alarms and warnings
RelatedDocumentation
T4000 PIC Description•
• T4000 PICs Supported on page 3
SONET/SDHOC48/STM16 (Multi-Rate) PICwith SFP (T4000 Router)
• Software Release on page 186
• Hardware Features on page 186
• Software Features on page 187
• Cables and Connectors on page 187
• LEDs on page 188
• Alarms, Errors, and Events on page 188
Software Release
Junos OS Release 12.2R2 and later (Type 2)
For information on which FPCs support this PIC, see “T4000 PIC/FPC Compatibility” on
page 8.
Hardware Features
• Rate-selectable using one of the following rates:
• 1-port OC3c/STM1c
• 1-port OC12/STM4
Copyright © 2017, Juniper Networks, Inc.186
T4000 Core Router Interface Module Reference
• 1-port OC12c/STM4c
• 1-port OC48/STM16
• 1-port OC48c/STM16c
• Power requirement: 0.20 A@ 48 V (9.5W)
• Model number: PB-1OC48-SON-B-SFP
• Multiplexing and demultiplexing
• Rate policing on input
• Rate shaping on output
• Packet buffering, Layer 2 parsing
Software Features
Table 112: Software Features Supported
T4000 First Supported Junos OSReleaseSoftware Feature
12.2R2Optical diagnostics and related alarms
12.2R2Per-port SONET/SDH framing
12.2R2IEEE 802.3ad Link Aggregation
12.2R2Alarm and event counting and detection
12.2R2Dual-router automatic protection switching (APS)
12.2R2Multiprotocol Label Switching (MPLS) fast reroute
12.2R2Layer 2 protocols:
• Circuit cross-connect (CCC)
• Translational cross-connect (TCC)
• Frame Relay
• High-Level Data Link Control (HDLC)
• Point-to-Point Protocol (PPP)
Cables and Connectors
You can install any transceiver supported by the PIC. For information about installing
and removing transceivers.
• Duplex LC connector (Rx and Tx)
• SONET/SDHOC3/STM1 small form-factor pluggable (SFP) transceivers:
• Multimode (model number: SFP-OC3-SR)
187Copyright © 2017, Juniper Networks, Inc.
Chapter 13: SONET/SDH PIC Descriptions
• Intermediate reach (IR-1) (model number: SFP-OC3-IR)
• Long reach (LR-1) (model number: SFP-OC3-LR)
Optical interface specifications—see “SONET/SDHOC3/STM1 Optical Interface
Specifications” on page 53
• SONET/SDHOC12/STM4 small form-factor pluggable (SFP) transceivers:
• Short reach (model number: SFP-OC12-SR)
• Intermediate reach (IR-1) (model number: SFP-OC312-IR)
• Long reach (LR-1) (model number: SFP-OC12-LR)
Optical interface specifications—see “SONET/SDHOC12/STM4 Optical Interface
Specifications” on page 55
• SONET/SDHOC48/STM16 fiber-optic SFP transceivers:
• Short reach (SR-1) (model number: SFP-1OC48-SR)
• Intermediate reach (IR-1) (model number: SFP-1OC48-IR)
• Long reach (LR-1) (model number: SFP-1OC48-LR)
Optical interface specifications—see “SONET/SDHOC48/STM16 Optical Interface
Specifications” on page 57
NOTE: To extend the life of the laser, when a PIC is not being actively usedwith any valid links, take the PIC offline until you are ready to establish a linkto another device. For information about taking a PIC offline, see the request
chassis pic offline command in request chassis pic.
LEDs
Table 113: SONET/SDHOC48/STM16 (Multi-Rate) PICwith SFP LEDs
DescriptionStateColorLabel
Not enabledOff—One tricolorper port
Online with no alarms or failuresOn steadilyGreen
Online with alarms for remote failuresOn steadilyYellow
Active with a local alarm; router has detected a failureOn steadilyRed
Alarms, Errors, and Events
• SONET alarms:
• Alarm indication signal—line (AIS-L)
• Alarm indication signal—path (AIS-P)
Copyright © 2017, Juniper Networks, Inc.188
T4000 Core Router Interface Module Reference
• Bit error rate—signal degrade (BERR-SD)
• Bit error rate—signal fail (BERR-SF)
• Bit interleaved parity (BIP) error B1, B2, B3
• Far-end bit error: remote error indication—line (REI-L), far-end line coding violations
(CV-LFE)
• Far-endbit error: remoteerror indication—path(REI-P), far-endpathcodingviolations
(CV-PFE)
• Loss of frame (LOF)
• Loss of pointer (LOP-P)
• Loss of signal (LOS)
• Payload label mismatch (PLM-P)
• Payload unequipped (unequipped STS at path level) (UNEQ-P)
• Remote defect indication—line (RDI-L)
• Remote defect indication—path (RDI-P)
• SDH alarms:
• Administrative unit alarm indication signal (AU-AIS)
• Bit error rate signal degrade (BERR-SD)
• Bit error rate signal fail (BERR-SF)
• Bit interleaved parity (BIP) error B1, B2, B3
• Higher order path—payload label mismatch (HP-PLM)
• Higher order path—loss of pointer (HP-LOP)
• Higher order path—remote defect indication (HP-RDI)
• Higher order path—unequipped (HP-UNEQ)
• Loss of frame (LOF)
• Loss of signal (LOS)
• Multiplex section—alarm indication signal (MS-AIS)
• Multiplex section—remote defect indication (MS-RDI)
• Multiplex section—remote error indication (MS-REI)
• Error detection:
• Errored seconds (ES-S, ES-L, ES-P)
• Far-end errored seconds (ES-LFE, ES-PFE)
• Far-end severely errored seconds (SES-LFE, SES-PFE)
• Far-end unavailable seconds (UAS-LFE, UAS-PFE)
189Copyright © 2017, Juniper Networks, Inc.
Chapter 13: SONET/SDH PIC Descriptions
• Severely errored framing (SEF)
• Severely errored framing seconds (SEFS-S)
• Severely errored seconds (SES-S, SES-L, SES-P)
• Unavailable seconds (UAS-L, UAS-P)
RelatedDocumentation
T4000 PIC Description•
• T4000 PICs Supported on page 3
SONET/SDHOC192/STM64 PICs with XFP (T4000 Router)
Figure21:4-PortSONET/SDHOC192/STM64PIC
Figure20: 1-PortSONET/SDHOC192/STM64PIC
• Software Release on page 191
• Hardware Features on page 191
• Software Features on page 191
• Cables and Connectors on page 192
• LEDs on page 192
• Alarms, Errors, and Events on page 193
Copyright © 2017, Juniper Networks, Inc.190
T4000 Core Router Interface Module Reference
Software Release
• 1-port: Junos OS Release 12.1R2 and later (Type 3)
• 4-port: Junos OS Release 12.1 and later (Type 4)
For information on which FPCs support this PIC, see “T4000 PIC/FPC Compatibility” on
page 8.
Hardware Features
• One or four OC192 ports
NOTE: Four OC192 links can be aggregated into one OC768 link or twoOC256 links. The four fiber links should be on the same fiber path or thesame fiber.
• Power requirement:
• 1-port (Type 3): 0.52 A@ 48 V (25W)
• 4-port (Type 4): 1.11 A@ 48 V (53.1 W)
• Model number for 1-port SONET/SDHOC192/STM64 PIC: PC-1OC192-SON-XFP
• Model number for 4-port SONET/SDHOC192/STM64 PIC: PD-4OC192-SON-XFP
• Multiplexing and demultiplexing
• Rate policing on input
• Rate shaping on output
• Packet buffering, Layer 2 parsing
Software Features
Table 114: Software Features Supported
T4000 First SupportedJunosOSRelease forType4 PIC
T4000 First SupportedJunos OS Release for Type3 PICSoftware Feature
12.1R112.1R2Configuration of SONET or SDH framing on a per-port basis onthe 4-port Type 4 PIC .
12.1R112.1R2SONET/SDH framing
12.1R112.1R2IEEE 802.3ad Link Aggregation
12.1R112.1R2Alarm and event counting and detection
12.1R112.1R2Dual-router automatic protection switching (APS)
191Copyright © 2017, Juniper Networks, Inc.
Chapter 13: SONET/SDH PIC Descriptions
Table 114: Software Features Supported (continued)
T4000 First SupportedJunosOSRelease forType4 PIC
T4000 First SupportedJunos OS Release for Type3 PICSoftware Feature
12.1R112.1R2Multiprotocol Label Switching (MPLS) fast reroute
12.1R112.1R2Encapsulations:
• Circuit cross-connect (CCC)
• Translational cross-connect (TCC)
• Frame Relay
• High-Level Data Link Control (HDLC)
• Point-to-Point Protocol (PPP)
Cables and Connectors
• Duplex LC connector (Rx and Tx)
• SONET/SDHOC192c/STM64 XFP transceivers:
• Short reach (SR-1) (model number: XFP-10G-L-OC192-SR1)
• Intermediate reach (IR-1) (model number: XFP-10G-E-OC192-IR2)
• Long reach (LR-1) (model number: XFP-10G-Z-OC192-LR2)
Optical interface specifications—see “SONET/SDHOC192/STM64 Optical Interface
Specifications” on page 60
NOTE: To extend the life of the laser, when a PIC is not being actively usedwith any valid links, take the PIC offline until you are ready to establish a linkto another device. For information about taking a PIC offline, see the request
chassis pic offline command in request chassis pic.
LEDs
Table 115: 1-Port SONET/SDHOC192/STM64 PIC LEDs
DescriptionStateColorLabel
Port is down.Off—LINK STATUS LED
Port is online. Link is established.On steadilyGreen
Copyright © 2017, Juniper Networks, Inc.192
T4000 Core Router Interface Module Reference
Table 116: 4-Port SONET/SDHOC192/STM64 PIC LEDs
DescriptionStateColorLabel
Not enabled.Off—Port LEDslabeled PORT0 throughPORT 3, onetricolor LEDperport
Online with no alarms or failures.On steadilyGreen
Online with alarms for remote failures.On steadilyYellow
Active with a local alarm; router has detected a failure.On steadilyRed
Not enabled.Off—One 768 over192 LED
Online with no alarms or failures.On steadilyGreen
Online with alarms for remote failures.On steadilyYellow
Active with a local alarm; router has detected a failure.On steadilyRed
Alarms, Errors, and Events
• SONET alarms:
• Alarm indication signal—line (AIS-L)
• Alarm indication signal—path (AIS-P)
• Bit error rate—signal degrade (BERR-SD)
• Bit error rate—signal fail (BERR-SF)
• Bit interleaved parity (BIP) error B1, B2, B3
• Far-end bit error: remote error indication—line (REI-L), far-end line coding violations
(CV-LFE)
• Far-endbit error: remoteerror indication—path(REI-P), far-endpathcodingviolations
(CV-PFE)
• Loss of frame (LOF)
• Loss of pointer (LOP-P)
• Loss of signal (LOS)
• Payload label mismatch (PLM-P)
• Payload unequipped (unequipped STS at path level) (UNEQ-P)
• Remote defect indication—line (RDI-L)
• Remote defect indication—path (RDI-P)
• SDH alarms:
193Copyright © 2017, Juniper Networks, Inc.
Chapter 13: SONET/SDH PIC Descriptions
• Administrative unit alarm indication signal (AU-AIS)
• Bit error rate signal degrade (BERR-SD)
• Bit error rate signal fail (BERR-SF)
• Bit interleaved parity (BIP) error B1, B2, B3
• Higher order path—payload label mismatch (HP-PLM)
• Higher order path—loss of pointer (HP-LOP)
• Higher order path—remote defect indication (HP-RDI)
• Higher order path—unequipped (HP-UNEQ)
• Loss of frame (LOF)
• Loss of signal (LOS)
• Multiplex section—alarm indication signal (MS-AIS)
• Multiplex section—remote defect indication (MS-RDI)
• Multiplex section—remote error indication (MS-REI)
• Error detection:
• Errored seconds (ES-S, ES-L, ES-P)
• Far-end errored seconds (ES-LFE, ES-PFE)
• Far-end severely errored seconds (SES-LFE, SES-PFE)
• Far-end unavailable seconds (UAS-LFE, UAS-PFE)
• Severely errored framing (SEF)
• Severely errored framing seconds (SEFS-S)
• Severely errored seconds (SES-S, SES-L, SES-P)
• Unavailable seconds (UAS-L, UAS-P)
RelatedDocumentation
T4000 PIC Description•
• T4000 PICs Supported on page 3
Copyright © 2017, Juniper Networks, Inc.194
T4000 Core Router Interface Module Reference
SONET/SDHOC768c/STM256 PIC (T4000 Router)
• Software Release on page 195
• Hardware Features on page 195
• Software Features on page 196
• Cables and Connectors on page 196
• LEDs on page 197
• Alarms, Errors, and Events on page 197
Software Release
Junos OS Release 12.1 and later (Type 4)
For information on which FPCs support this PIC, see “T4000 PIC/FPC Compatibility” on
page 8.
Hardware Features
• One OC768 port
• Power requirement: 1.37 A@ 48 V (65.7W)
• Model number: PD-1OC768-SON-SR
• Multiplexing and demultiplexing
• Rate policing on input
195Copyright © 2017, Juniper Networks, Inc.
Chapter 13: SONET/SDH PIC Descriptions
• Rate shaping on output
• Packet buffering, Layer 2 parsing
Software Features
Table 117: Software Features Supported
T4000 First Supported JunosOS ReleaseSoftware Feature
12.1SONET/SDH framing
12.1IEEE 802.3ad Link Aggregation
12.1Alarm and event counting and detection
12.1Dual-router automatic protection switching (APS)
12.1Multiprotocol Label Switching (MPLS) fast reroute
12.1Layer 2 protocols:
• Circuit cross-connect (CCC)
• Translational cross-connect (TCC)
• Frame Relay
• High-Level Data Link Control (HDLC)
• Point-to-Point Protocol (PPP)
12.1Optical diagnostics and related alarms
• Laser bias
• Transmit optical power
• Receiver optical power
• Laser temperature
Cables and Connectors
• Duplex SC connector (Rx and Tx)
• SONET/SDHOC768c/STM265 Short reach (SR-1) fixed transceiver
Optical interface specifications—see “SONET/SDHOC768/STM256 Optical Interface
Specifications” on page 63
NOTE: To extend the life of the laser, when a PIC is not being actively usedwith any valid links, take the PIC offline until you are ready to establish a linkto another device. For information about taking a PIC offline, see the request
chassis pic offline command in request chassis pic.
Copyright © 2017, Juniper Networks, Inc.196
T4000 Core Router Interface Module Reference
LEDs
Table 118: SONET/SDHOC768c/STM256 PIC LEDs
DescriptionStateColorLabel
Not enabled.Off—STATUS
Online with no alarms or failures.On steadilyGreen
Online with alarms for remote failures.On steadilyYellow
Active with a local alarm; router has detected a failure.On steadilyRed
Alarms, Errors, and Events
• SONET alarms:
• Alarm indication signal—line (AIS-L)
• Alarm indication signal—path (AIS-P)
• Bit error rate—signal degrade (BERR-SD)
• Bit error rate—signal fail (BERR-SF)
• Bit interleaved parity (BIP) error B1, B2, B3
• Far-end bit error: remote error indication—line (REI-L), far-end line coding violations
(CV-LFE)
• Far-endbit error: remoteerror indication—path(REI-P), far-endpathcodingviolations
(CV-PFE)
• Loss of frame (LOF)
• Loss of pointer (LOP-P)
• Loss of signal (LOS)
• Payload label mismatch (PLM-P)
• Payload unequipped (unequipped STS at path level) (UNEQ-P)
• Remote defect indication—line (RDI-L)
• Remote defect indication—path (RDI-P)
• SDH alarms:
• Administrative unit alarm indication signal (AU-AIS)
• Bit error rate signal degrade (BERR-SD)
• Bit error rate signal fail (BERR-SF)
• Bit interleaved parity (BIP) error B1, B2, B3
• Higher order path—payload label mismatch (HP-PLM)
197Copyright © 2017, Juniper Networks, Inc.
Chapter 13: SONET/SDH PIC Descriptions
• Higher order path—loss of pointer (HP-LOP)
• Higher order path—remote defect indication (HP-RDI)
• Higher order path—unequipped (HP-UNEQ)
• Loss of frame (LOF)
• Loss of signal (LOS)
• Multiplex section—alarm indication signal (MS-AIS)
• Multiplex section—remote defect indication (MS-RDI)
• Multiplex section—remote error indication (MS-REI)
• Error detection:
• Errored seconds (ES-S, ES-L, ES-P)
• Far-end errored seconds (ES-LFE, ES-PFE)
• Far-end severely errored seconds (SES-LFE, SES-PFE)
• Far-end unavailable seconds (UAS-LFE, UAS-PFE)
• Severely errored framing (SEF)
• Severely errored framing seconds (SEFS-S)
• Severely errored seconds (SES-S, SES-L, SES-P)
• Unavailable seconds (UAS-L, UAS-P)
RelatedDocumentation
• T4000 PIC Description
• T4000 PICs Supported on page 3
Copyright © 2017, Juniper Networks, Inc.198
T4000 Core Router Interface Module Reference
CHAPTER 14
End-of-Life PIC Descriptions
• 10-Gigabit Ethernet DWDMOTN EOL PIC (T4000 Router) on page 199
• SONET/SDHOC12c/STM4 EOL PIC (T4000 Router) on page 201
• SONET/SDHOC48c/STM16 EOL PICs (T4000 Router) on page 205
• SONET/SDHOC48c/STM16 EOL PIC with SFP (T4000 Router) on page 209
• SONET/SDHOC192/STM64 EOL PIC (T4000 Router) on page 212
10-Gigabit Ethernet DWDMOTN EOL PIC (T4000 Router)
g003
926
• Software Release on page 199
• Hardware Features on page 200
• Software Features on page 200
• Cables and Connectors on page 200
• LEDs on page 201
Software Release
Junos OS Release 12.1R2 and later (Type 3)
199Copyright © 2017, Juniper Networks, Inc.
For information on which FPCs support this PIC, see “T4000 PIC/FPC Compatibility” on
page 8.
Hardware Features
• One 10-Gigabit Optical Transport Network (OTN) port for transport of 10-Gigabit
Ethernet (10GBASE-R) traffic
• Power requirement: 0.55 A@ 48 V (26.6W)
• Supports largeEthernet framesizes formoreefficient throughputacross the intra-POP
network
• Model number: PC-1XGE-DWDM-OTN
• C-band ITU-Grid with 50 GHz spacing
• High-performance throughput at speeds up to 10 Gbps
• Full-duplex mode
• Maximum transmission units (MTUs) up to 9192 bytes
• 64 source MAC address filters
• 960 destination MAC filters
• 89 individual wavelengths
Software Features
Table 119: Software Features Supported
T4000 First Supported JunosOSReleaseSoftware Feature
12.1R2Enhanced optical monitoring capabilities
12.1R2CLI configurable wavelength support
12.1R2Virtual Router Redundancy Protocol (VRRP) support
12.1R2802.1q virtual LANs (VLANs) support
12.1R2IEEE 802.3ad Link Aggregation
12.1R2RMON EtherStats
Cables and Connectors
• Duplex SC/PC connector (RX and TX)
• Fixed transceiver
• Dense wavelength division multiplexing (DWDM) optical transport network (OTN)
transceiver.
Copyright © 2017, Juniper Networks, Inc.200
T4000 Core Router Interface Module Reference
Optical interfacespecifications—see “10-GigabitEthernetDWDMOTNOptical Interface
Specifications” on page 39 and “10-Gigabit Ethernet 10GBASE Optical Interface
Specifications” on page 34.
LEDs
Table 120: 10-Gigabit Ethernet DWDMOTN EOL PIC LEDs
DescriptionStateColorLabel
PIC is not enabled.Off—STATUS LED, onebicolor
PIC is operating normally.On steadilyGreen
PIC has an error or is in line-side loopback.On steadilyRed
RelatedDocumentation
T4000 PIC Description•
• T4000 PICs Supported on page 3
SONET/SDHOC12c/STM4 EOL PIC (T4000 Router)
Figure 22: 4-Port SONET/SDHOC12c/STM4 PIC
• Software Release on page 201
• Hardware Features on page 202
• Software Features on page 202
• Cables and Connectors on page 202
• LEDs on page 203
• Alarms, Errors, and Events on page 203
Software Release
Junos OS Release 12.2R2 and later (Type 2)
201Copyright © 2017, Juniper Networks, Inc.
Chapter 14: End-of-Life PIC Descriptions
For information on which FPCs support this PIC, see “T4000 PIC/FPC Compatibility” on
page 8.
Hardware Features
• Four ports
• Power requirement: 0.23 A@ 48 V (10.8W)
• Model number: PB-4OC12-SON-MM
• Model number: PB-4OC12-SON-SMIR
• Multiplexing and demultiplexing
• Rate policing on input
• Rate shaping on output
• Packet buffering, Layer 2 parsing
Software Features
Table 121: Software Features Supported
T4000 First Supported Junos OSReleaseSoftware Feature
12.2R2SONET/SDH framing
12.2R2IEEE 802.3ad Link Aggregation
12.2R2Alarm and event counting and detection
12.2R2Dual-router automatic protection switching (APS)
12.2R2Multiprotocol Label Switching (MPLS) fast reroute
12.2R2Layer 2 protocols:
• High-Level Data Link Control (HDLC)
• Frame Relay
• Circuit cross-connect (CCC)
• Translational cross-connect (TCC)
• Point-to-Point Protocol (PPP)
Cables and Connectors
• Duplex SC connector (Rx and Tx)
• SONET/SDHOC12/STM4 fixed transceiver:
4-port: Multimode
4-port: Single-mode Intermediate reach (IR-1)
Copyright © 2017, Juniper Networks, Inc.202
T4000 Core Router Interface Module Reference
Optical interface specifications—see “SONET/SDHOC12/STM4 Optical Interface
Specifications” on page 55
NOTE: To extend the life of the laser, when a PIC is not being actively usedwith any valid links, take the PIC offline until you are ready to establish a linkto another device. For information about taking a PIC offline, see the request
chassis pic offline command in request chassis pic.
LEDs
Table 122: SONET/SDHOC12c/STM4 EOL PIC LEDs
DescriptionStateColorLabel
Not enabled.Off—One tricolorper port
Online with no alarms or failures.On steadilyGreen
Online with alarms for remote failures.On steadilyYellow
Active with a local alarm; router has detected a failure.On steadilyRed
Alarms, Errors, and Events
• SONET alarms:
• Alarm indication signal—line (AIS-L)
• Alarm indication signal—path (AIS-P)
• Bit error rate signal degrade (BERR-SD)
• Bit error rate signal fail (BERR-SF)
• Bit interleaved parity (BIP) error B1
• Bit interleaved parity (BIP) error B2
• Bit interleaved parity (BIP) error B3
• Loss of frame (LOF)
• Loss of pointer (LOP-P)
• Loss of signal (LOS)
• Far-end bit error: remote error indication—line (REI-L) (CV-LFE)
• Far-end bit error: remote error indication—path (REI-P) (CV-PFE)
• Payloadmismatch (path label mismatch) (PLM-P)
• Payload unequipped (unequipped STS at path level) (UNEQ-P)
203Copyright © 2017, Juniper Networks, Inc.
Chapter 14: End-of-Life PIC Descriptions
• Remote defect indication—line (RDI-L)
• Remote defect indication—path (RDI-P)
• SDH alarms:
• Multiplex section alarm indication signal (MS-AIS)
• Administrative unit alarm indication signal (AU-AIS)
• Bit error rate signal degrade (BERR-SD)
• Bit error rate signal fail (BERR-SF)
• Bit interleaved parity (BIP) error B1
• Bit interleaved parity (BIP) error B2
• Bit interleaved parity (BIP) error B3
• Loss of frame (LOF)
• Loss of pointer (HP-LOP)
• Loss of signal (LOS)
• Multiplex section remote error indication (MS-REI)
• Higher path label mismatch (HP-PLM)
• Higher path unequipped (HP-UNEQ)
• Multiplex section remote defect indication (MS-RDI)
• Higher path remote defect indication (HP-RDI)
• Erroredseconds (ES-S,ES-L, ES-P), far-enderroredseconds (ES-LFE,ES-PFE), far-end
severely errored seconds (SES-LFE,SES-PFE), far-endunavailable seconds (UAS-LFE,
UAS-PFE)
• Severely errored framing (SEF), severely errored framing seconds (SEFS-S), severely
errored seconds (SES-S, SES-L, SES-P), unavailable seconds (UAS-L, UAS-P)
RelatedDocumentation
T4000 PIC Description•
• T4000 PICs Supported on page 3
Copyright © 2017, Juniper Networks, Inc.204
T4000 Core Router Interface Module Reference
SONET/SDHOC48c/STM16 EOL PICs (T4000 Router)
Figure24:4-PortSONET/SDHOC48c/STM16PIC
Figure23: 1-PortSONET/SDHOC48c/STM16PIC
• Software Release on page 205
• Hardware Features on page 205
• Software Features on page 206
• Cables and Connectors on page 206
• LEDs on page 207
• Alarms, Errors, and Events on page 207
Software Release
• 1-port: Junos OS Release 12.2R2 and later (Type 2)
• 4-port: Junos OS Release 12.1R2 and later (Type 3)
For information on which FPCs support this PIC, see “T4000 PIC/FPC Compatibility” on
page 8.
Hardware Features
• One or four OC48 ports
• 1-port: 0.38 A@ 48 V (8W)
• 4-port: 0.86 A@ 48 V (41.4W)
• Model number for 1-port SONET/SDHOC48c/STM16 PIC: PB-1OC48-SON-SMSR
• Model number for 4-port SONET/SDHOC48c/STM16 PIC: PC-4OC48-SON-SMSR
• Multiplexing and demultiplexing
• Rate policing on input
205Copyright © 2017, Juniper Networks, Inc.
Chapter 14: End-of-Life PIC Descriptions
• Rate shaping on output
• Packet buffering, Layer 2 parsing
Software Features
Table 123: Software Features Supported
T4000 First SupportedJunos OS Release (Type 3)
T4000 First SupportedJunos OS Release (Type 2)Software Feature
12.1R212.2R2SONET/SDH framing
12.1R212.2R2IEEE 802.3ad Link Aggregation
12.1R212.2R2Alarm and event counting and detection
12.1R212.2R2Dual-router automatic protection switching (APS)
12.1R212.2R2Multiprotocol Label Switching (MPLS) fast reroute
12.1R212.2R2Layer 2 protocols:
• High-Level Data Link Control (HDLC)
• Frame Relay
• Circuit cross-connect (CCC)
• Translational cross-connect (TCC)
• Point-to-Point Protocol (PPP)
Cables and Connectors
• Duplex SC Connector (Rx and Tx)
• 1-port and 4-port: SONET/SDHOC48/STM16 fixed transceiver: short reach (SR-1)
• 1-port: Long reach (LR-1)
• Optical interface specifications—see “SONET/SDHOC48/STM16 Optical Interface
Specifications” on page 57
NOTE: To extend the life of the laser, when a PIC is not being actively usedwith any valid links, take the PIC offline until you are ready to establish a linkto another device. For information about taking a PIC offline, see the request
chassis pic offline command in request chassis pic.
Copyright © 2017, Juniper Networks, Inc.206
T4000 Core Router Interface Module Reference
LEDs
Table 124: SONET/SDHOC48c/STM16 EOL PICs LEDs
DescriptionStateColorLabel
Not enabled.Off—STATUS LED, one tricolor perport
Online with no alarms orfailures.
On steadilyGreen
Onlinewithalarms for remotefailures.
On steadilyYellow
Active with a local alarm;router has detected a failure.
On steadilyRed
Alarms, Errors, and Events
• SONET alarms:
• Alarm indication signal—line (AIS-L)
• Alarm indication signal—path (AIS-P)
• Bit error rate signal degrade (BERR-SD)
• Bit error rate signal fail (BERR-SF)
• Bit interleaved parity (BIP) error B1
• Bit interleaved parity (BIP) error B2
• Bit interleaved parity (BIP) error B3
• Loss of frame (LOF)
• Loss of pointer (LOP-P)
• Loss of signal (LOS)
• Far-end bit error: remote error indication—line (REI-L) (CV-LFE)
• Far-end bit error: remote error indication—path (REI-P) (CV-PFE)
• Payloadmismatch (path label mismatch) (PLM-P)
• Payload unequipped (unequipped STS at path level) (UNEQ-P)
• Remote defect indication—line (RDI-L)
• Remote defect indication—path (RDI-P)
• SDH alarms:
• Multiplex section alarm indication signal (MS-AIS)
• Administrative unit alarm indication signal (AU-AIS)
• Bit error rate signal degrade (BERR-SD)
207Copyright © 2017, Juniper Networks, Inc.
Chapter 14: End-of-Life PIC Descriptions
• Bit error rate signal fail (BERR-SF)
• Bit interleaved parity (BIP) error B1
• Bit interleaved parity (BIP) error B2
• Bit interleaved parity (BIP) error B3
• Loss of frame (LOF)
• Loss of pointer (HP-LOP)
• Loss of signal (LOS)
• Multiplex section remote error indication (MS-REI)
• Higher path label mismatch (HP-PLM)
• Higher path unequipped (HP-UNEQ)
• Multiplex section remote defect indication (MS-RDI)
• Higher path remote defect indication (HP-RDI)
• Erroredseconds (ES-S,ES-L, ES-P), far-enderroredseconds (ES-LFE,ES-PFE), far-end
severely errored seconds (SES-LFE,SES-PFE), far-endunavailable seconds (UAS-LFE,
UAS-PFE)
• Severely errored framing (SEF), severely errored framing seconds (SEFS-S), severely
errored seconds (SES-S, SES-L, SES-P), unavailable seconds (UAS-L, UAS-P)
RelatedDocumentation
T4000 PIC Description•
• T4000 PICs Supported on page 3
Copyright © 2017, Juniper Networks, Inc.208
T4000 Core Router Interface Module Reference
SONET/SDHOC48c/STM16 EOL PICwith SFP (T4000 Router)
• Software Release on page 209
• Hardware Features on page 209
• Software Features on page 210
• Cables and Connectors on page 210
• LEDs on page 211
• Alarms, Errors, and Events on page 211
Software Release
Junos OS Release 12.2R2 and later (Type 2)
For information on which FPCs support this PIC, see “T4000 PIC/FPC Compatibility” on
page 8.
Hardware Features
• One OC48 port
• Power requirement: 0.33 A@ 48 V (16W)
• Model number: PB-1OC48-SON-SFP
• Multiplexing and demultiplexing
• Rate policing on input
• Rate shaping on output
• Packet buffering, Layer 2 parsing
209Copyright © 2017, Juniper Networks, Inc.
Chapter 14: End-of-Life PIC Descriptions
Software Features
Table 125: Software Features Supported
T4000 First Supported Junos OSReleaseSoftware Feature
12.2R2SONET/SDH framing
12.2R2IEEE 802.3ad Link Aggregation
12.2R2Alarm and event counting and detection
12.2R2Dual-router automatic protection switching (APS)
12.2R2Multiprotocol Label Switching (MPLS) fast reroute
12.2R2Layer 2 protocols:
• High-Level Data Link Control (HDLC)
• Frame Relay
• Circuit cross-connect (CCC)
• Translational cross-connect (TCC)
• Point-to-Point Protocol (PPP)
Cables and Connectors
• Duplex LC Connector (Rx and Tx)
• SONET/SDHOC48/STM16 fiber-optic SFP transceivers:
• Short reach (SR-1) (model number: SFP-1OC48-SR)
• Intermediate reach (IR-1) (model number: SFP-1OC48-IR)
• Long reach (LR-1) (model number: SFP-1OC48-LR)
Optical interface specifications—see “SONET/SDHOC48/STM16 Optical Interface
Specifications” on page 57
NOTE: To extend the life of the laser, when a PIC is not being actively usedwith any valid links, take the PIC offline until you are ready to establish a linkto another device. For information about taking a PIC offline, see the request
chassis pic offline command in request chassis pic.
Copyright © 2017, Juniper Networks, Inc.210
T4000 Core Router Interface Module Reference
LEDs
Table 126: SONET/SDHOC48c/STM16 EOL PICwith SFP LEDs
DescriptionStateColorLabel
Not enabledOff—One tricolorper port
Online with no alarms or failuresOn steadilyGreen
Online with alarms for remote failuresOn steadilyYellow
Active with a local alarm; router has detected a failureOn steadilyRed
Alarms, Errors, and Events
• SONET alarms:
• Alarm indication signal—line (AIS-L)
• Alarm indication signal—path (AIS-P)
• Bit error rate signal degrade (BERR-SD)
• Bit error rate signal fail (BERR-SF)
• Bit interleaved parity (BIP) error B1
• Bit interleaved parity (BIP) error B2
• Bit interleaved parity (BIP) error B3
• Loss of frame (LOF)
• Loss of pointer (LOP-P)
• Loss of signal (LOS)
• Far-end bit error: remote error indication—line (REI-L) (CV-LFE)
• Far-end bit error: remote error indication—path (REI-P) (CV-PFE)
• Payloadmismatch (path label mismatch) (PLM-P)
• Payload unequipped (unequipped STS at path level) (UNEQ-P)
• Remote defect indication—line (RDI-L)
• Remote defect indication—path (RDI-P)
• SDH alarms:
• Multiplex section alarm indication signal (MS-AIS)
• Administrative unit alarm indication signal (AU-AIS)
• Bit error rate signal degrade (BERR-SD)
• Bit error rate signal fail (BERR-SF)
211Copyright © 2017, Juniper Networks, Inc.
Chapter 14: End-of-Life PIC Descriptions
• Bit interleaved parity (BIP) error B1
• Bit interleaved parity (BIP) error B2
• Bit interleaved parity (BIP) error B3
• Loss of frame (LOF)
• Loss of pointer (HP-LOP)
• Loss of signal (LOS)
• Multiplex section remote error indication (MS-REI)
• Higher path label mismatch (HP-PLM)
• Higher path unequipped (HP-UNEQ)
• Multiplex section remote defect indication (MS-RDI)
• Higher path remote defect indication (HP-RDI)
• Erroredseconds (ES-S,ES-L, ES-P), far-enderroredseconds (ES-LFE,ES-PFE), far-end
severely errored seconds (SES-LFE,SES-PFE), far-endunavailable seconds (UAS-LFE,
UAS-PFE)
• Severely errored framing (SEF), severely errored framing seconds (SEFS-S), severely
errored seconds (SES-S, SES-L, SES-P), unavailable seconds (UAS-L, UAS-P)
RelatedDocumentation
T4000 PIC Description•
• T4000 PICs Supported on page 3
SONET/SDHOC192/STM64 EOL PIC (T4000 Router)
• Software Release on page 213
• Hardware Features on page 213
• Software Features on page 213
• Cables and Connectors on page 214
Copyright © 2017, Juniper Networks, Inc.212
T4000 Core Router Interface Module Reference
• LEDs on page 214
• Alarms, Errors, and Events on page 214
Software Release
Junos OS Release 12.1R2 and later (Type 3)
Hardware Features
• One OC192 port
• Power requirement: 0.45 A@ 48 V (21.6W)
• Model number: PC-1OC192-SON-SR2
• Multiplexing and demultiplexing
• Rate policing on input
• Rate shaping on output
• Packet buffering, Layer 2 parsing
Software Features
Table 127: Software Features Supported
T4000 First Supported Junos OSReleaseSoftware Feature
12.1R2SONET/SDH framing
12.1R2IEEE 802.3ad Link Aggregation
12.1R2Alarm and event counting and detection
12.1R2Dual-router automatic protection switching (APS)
12.1R2Multiprotocol Label Switching (MPLS) fast reroute
12.1R2Layer 2 protocols:
• High-Level Data Link Control (HDLC)
• Frame Relay
• Circuit cross-connect (CCC)
• Translational cross-connect (TCC)
• Point-to-Point Protocol (PPP)
213Copyright © 2017, Juniper Networks, Inc.
Chapter 14: End-of-Life PIC Descriptions
Cables and Connectors
SONET/SDHOC192/STM64 fixed transceiver: Short reach (SR-2): duplex SC connector
(Rx and Tx)
• Optical interface specifications—see “SONET/SDHOC192/STM64 Optical Interface
Specifications” on page 60
NOTE: To extend the life of the laser, when a PIC is not being actively usedwith any valid links, take the PIC offline until you are ready to establish a linkto another device. For information about taking a PIC offline, see the request
chassis pic offline command in request chassis pic.
LEDs
Table 128: SONET/SDHOC192/STM64 EOL PIC LEDs
DescriptionStateColorLabel
Not enabledOff—STATUS LED,one tricolor
Online with no alarms or failuresOn steadilyGreen
Online with alarms for remote failuresOn steadilyYellow
Active with a local alarm; router has detected a failureOn steadilyRed
Alarms, Errors, and Events
• SONET alarms:
• Alarm indication signal—line (AIS-L)
• Alarm indication signal—path (AIS-P)
• Bit error rate signal degrade (BERR-SD)
• Bit error rate signal fail (BERR-SF)
• Bit interleaved parity (BIP) error B1
• Bit interleaved parity (BIP) error B2
• Bit interleaved parity (BIP) error B3
• Loss of frame (LOF)
• Loss of pointer (LOP-P)
• Loss of signal (LOS)
• Far-end bit error: remote error indication—line (REI-L) (CV-LFE)
• Far-end bit error: remote error indication—path (REI-P) (CV-PFE)
Copyright © 2017, Juniper Networks, Inc.214
T4000 Core Router Interface Module Reference
• Payloadmismatch (path label mismatch) (PLM-P)
• Payload unequipped (unequipped STS at path level) (UNEQ-P)
• Remote defect indication—line (RDI-L)
• Remote defect indication—path (RDI-P)
• SDH alarms:
• Multiplex section alarm indication signal (MS-AIS)
• Administrative unit alarm indication signal (AU-AIS)
• Bit error rate signal degrade (BERR-SD)
• Bit error rate signal fail (BERR-SF)
• Bit interleaved parity (BIP) error B1
• Bit interleaved parity (BIP) error B2
• Bit interleaved parity (BIP) error B3
• Loss of frame (LOF)
• Loss of pointer (HP-LOP)
• Loss of signal (LOS)
• Multiplex section remote error indication (MS-REI)
• Higher path label mismatch (HP-PLM)
• Higher path unequipped (HP-UNEQ)
• Multiplex section remote defect indication (MS-RDI)
• Higher path remote defect indication (HP-RDI)
• Erroredseconds (ES-S,ES-L, ES-P), far-enderroredseconds (ES-LFE,ES-PFE), far-end
severely errored seconds (SES-LFE,SES-PFE), far-endunavailable seconds (UAS-LFE,
UAS-PFE)
• Severely errored framing (SEF), severely errored framing seconds (SEFS-S), severely
errored seconds (SES-S, SES-L, SES-P), unavailable seconds (UAS-L, UAS-P)