— Frequency converter FIU
— Top-hat mounting according to DIN 50022
— Key-pad programmable
— LC display
— Analog output and switch output
T510 Frequency converterVarious signal transmission for flowrate measuring
Display mode Hz Error
l/min Smoothing
l/h Pulse/Einheit
m3/h Bounce filter
Unit m3/h Start-up override
Input
Output Relay 1 Limit Min/Max
Relay 2 Serial switching Trip
OT1 Pulse divider Hysteresis
IOUT Characteristic Mode
Service Password Alarm freeze
Language
Water MeteringTHE POWER OF CONNECTED
T510 Frequency converter Technical Data
104
40 110
Connection
1 + brown2 – white3 A green
10
111216
1718
19
20
8
7
Outputs
DC ≤ 40 V ≤ 2 A
Umax ≤ 40 VJmax ≤ 50 mA
0/4 ... 20 mARmax = 650 Ohm
AC ≤ 253 V ≤ 2 Ap.f. 0.7
I.
II.
III.
IV.
Inputs
Optoelectronical contactor PV 14T180
Inductive contactorPV 13-3T170
Reedcontactore.g. T160
R
13 +
14 –
Start-up override
1 + brown
3 – white
1 + brown
3 – white
NAMURDIN19234
+
–
23 24
Mains nominal voltage 20 ... 90 V DC / 48 ... 253 V ACNominal current 100 ... 40 mA / 30 ... 15 mA
1 + yellow
3 – black
Falconpulse modulePR6/PR7
MainsConnection clutch 23 +, 24 –Power Ue 20 ... 90 V DC
48 ... 253 V ACPower loss 2 W / 2,5 VAPower drain 2.2 W / 3 VA Galvanical separation all inputs / outputsRated insulation voltage 253 Veff , all inputs / outputsOutputsConnection I clutch 10, 11, 12
II clutch 16, 17, 18III clutch 19 +, 20 –IV clutch 8 +, 7 –
Output I and II signal, relayContact load 250 V AC / 2 A / cos j = 0.7
40 V DC / 2 ALifetime 5 x 107 operating cyclesAnzugs- / Abfallverzug approx. 20 ms / approx. 20 msOutput III electronics, passiveSignal level I-signal (L+) – 2,5 V (50 mA)
short-circuit proof and overload proof0-signal closed exit, rest curent < 10 µA
Voltage Um 40 VOutput IV analogueCurrent brand 0 ... 20 mA / 4 ... 20 mAOpen-circuit voltage 24 V DCLoad impedance 650 OhmError message up I = 3.6 mA
down I = 21 mAacc. NAMUR NE 43
InputsConnection two wire sensor clutch 1 +, 3 –
three wire sensor clutch 1+, 2 –, 3 (signal)start-up override clutch 13 +, 14 –
Input I sensorInput resistor 1.2 kOhmInput pulse Länge / Pause > 50 µs / > 50 µsVoltage 13 V DCOpen-circuit voltage 13 V DCCurrent < 30 mATamper breakage I < 0,15 mA
short circuit I > 6.5 mAInput IIStart-up override adjustable 1, 2, 3 ... 1 000 sOpeb-circuit voltage 18 V DCShort circuit current 5 mAActive I > 4 mA (> 100 ms)Passive I < 1.5 mACharacteristics of transmissionMeasuring range fn 0.001 Hz ... 12 kHzMeasuring accuracy < 20 µA + 2 % v MWUmgebungsbedingungOperating temperature – 20 ... + 60 °C
253 ... 333 K
Dimensional drawing
Elster Water Metering Limited130 Camford Way, Sundon ParkLuton, Bedfordshire, LU3 3ANUnited KingdomT: +44 (0) 1582 846400F: +44 (0) 1582 564728 [email protected]
For further information visit:www.elstermetering.com
2017 by Elster Water Metering Ltd. All rights reserved. The company's police is one of continuous product improvement and the right is reserved to modify the specifications contained herein without notice.
T510_D_14.11e / 03.17 THE POWER OF CONNECTED