2
Date of last revision: 10.06 CALIBRATION GUIDES TREADMILL.CALIB.TM240.TC173W.REV1 1 T9200 (TM240) Deluxe (TC173W) Calibration Guide CONFIRM MODEL AND SOFTWARE STEP 1 • With the safety key in place, hold the “ELEVATION UP” and “SPEED DOWN” buttons at the same time (for about 3-5 seconds). The console will beep three times. The treadmill is now in engineering mode. • The distance window displays the model number. • The time window displays the software version. (Example: “S802”). • The profile matrix window displays MI (miles) or KM (kilometers) STEP 2 • Press the “STOP” button. The console will beep three times. You are now in the main engineering menu. MANUAL CALIBRATION MODE, ENG1 STEP 3 • Press “ENTER” button, “P6” will appear in display. STEP 4 MINIMUM SPEED (P0) • Press “ELEVATION DOWN” to “P0”. Press “ENTER” button. The belt will begin to move. The speed window should display approximately “.50”. If not “.50” use “SPEED” buttons to adjust. The time window should display a number within the range of “415 - 425”. • If changes have been made, press and hold the “ENTER” button, to save changes, or press the “STOP” button to exit back to menu. STEP 5 SP1 SPD (SP1) • Press “ELEVATION UP” button to “SP1”. • Press “ENTER” button. The belt will begin to move. The speed window should display approximately “1.8”. If not “1.8” use “SPEED” buttons to adjust. The time window should display a number within the range of “1870 - 1885”. • If changes have been made, press and hold the “ENTER” button, to save changes, or press the “STOP” button to exit back to menu. STEP 6 MID SPEED (P1) • Press “ELEVATION UP” button to “P1”. • Press “ENTER” button. The belt will begin to move. The speed window should display approximately “4.4”. If not “4.4” use “SPEED” buttons to adjust. The time window should display a number within the range of “1865 - 1885”. • If changes have been made, press and hold the “ENTER” button, to save changes, or press the “STOP” button to exit back to menu.

T9200 (TM240) Deluxe (TC173W) Calibration Guide

  • Upload
    others

  • View
    11

  • Download
    0

Embed Size (px)

Citation preview

Date of last revision: 10.06

CALIB

RATIO

N GU

IDES

TREADMILL.CALIB.TM240.TC173W.REV11

T9200 (TM240) Deluxe (TC173W)Calibration Guide

CONFIRM MODEL AND SOFTWARE STEP 1

• With the safety key in place, hold the “ELEVATION UP” and “SPEEDDOWN” buttons at the same time (for about 3-5 seconds). The consolewill beep three times. The treadmill is now in engineering mode.

• The distance window displays the model number.• The time window displays the software version. (Example: ““SS880022””). • The profile matrix window displays MI (miles) or KM (kilometers)

STEP 2• Press the “STOP” button. The console will beep three times. You are

now in the main engineering menu.

MANUAL CALIBRATION MODE, ENG1STEP 3

• Press “ENTER” button, ““PP66”” will appear in display.

STEP 4 MINIMUM SPEED (P0)• Press “ELEVATION DOWN” to ““PP00””. Press “ENTER” button. The belt

will begin to move. The speed window should display approximately““..5500””. If not ““..5500”” use “SPEED” buttons to adjust. The time window shoulddisplay a number within the range of ““441155 -- 442255””.

• If changes have been made, press and hold the “ENTER” button, tosave changes, or press the “STOP” button to exit back to menu.

STEP 5 SP1 SPD (SP1)• Press “ELEVATION UP” button to ““SSPP11””. • Press “ENTER” button. The belt will begin to move. The speed window

should display approximately ““11..88””. If not ““11..88”” use “SPEED” buttons to adjust.The time window should display a number within the range of ““11887700 -- 11888855””.

• If changes have been made, press and hold the “ENTER” button, tosave changes, or press the “STOP” button to exit back to menu.

STEP 6 MID SPEED (P1)• Press “ELEVATION UP” button to ““PP11””.• Press “ENTER” button. The belt will begin to move. The speed window

should display approximately ““44..44””. If not ““44..44”” use “SPEED” buttons toadjust. The time window should display a number within the range of““11886655 -- 11888855””.

• If changes have been made, press and hold the “ENTER” button, tosave changes, or press the “STOP” button to exit back to menu.

Date of last revision: 10.06

CALIBRATIONGUIDES

TREADMILL.CALIB.TM240.TC173W.REV1 2

ILLUSTRATIONS FOR DISPLAY PURPOSES ONLY

STEP 7 SP2 SPD (SP2)• Press “ELEVATION UP” button to ““SSPP22””. • Press “ENTER” button. The belt will begin to move. The speed window

should display approximately ““66..22””. If not ““66..22”” use “SPEED” buttons toadjust. The time window should display a number within the range of““22558800 -- 22660000””.

• If changes have been made, press and hold the “ENTER” button, tosave changes, or press the “STOP” button to exit back to menu.

STEP 8 MAX SPEED (P2)• Press “ELEVATION UP” button to ““PP22””, ““MMAAXX SSPPEEEEDD””.• Press “ENTER” button. The belt will begin to move. The speed window

should display ““1100..00””. If not ““1100..00”” use “SPEED” buttons to adjust. The time window should display a number within the range of ““44112200 -- 44114400””.

• If changes have been made, press and hold the “ENTER” button, tosave changes, or press the “STOP” button to exit back to menu.

STEP 9 MINIMUM ELEVATION (P4)• Press “ELEVATION UP” button to ““PP44””, ““EELLEE ZZEERROO””

• Press “ENTER” button. The time window should display a number withina range of ““7755 -- 8855””. Use “SPEED” button to change the number in theelevation window within the range.

• If changes have been made, press and hold the “ENTER” button, tosave changes, or press the “STOP” button to exit back to menu.

STEP 10 MAXIMUM ELEVATION (P5) • Press “ELEVATION UP" button to ““PP55””, ““EELLEE MMAAXX””.• Press “ENTER” button. The time window should display a number

between a range of ““661155 -- 663300””. If the number does not fall within therange, use the “SPEED” buttons to change the number in the elevationwindow within the range.

• If changes have been made, press and hold the “ENTER” button, tosave changes, or press the “STOP” button to exit back to menu.

STEP 11 EXIT TO ENG1 (P17) • Press “ELEVATION UP” button to ““PP1177””.• Press “ENTER” button.• Press and hold “STOP” button to return to the main user program window.

The deck will lower to level position.

T9200 (TM240) Deluxe (TC173W)Calibration Guide continued