    KUMPULAN TABEL MIL-STD-105E

    Ir. Budi Nurtama, M.Agr.

    2008

    Program Studi Supervisor Jaminan Mutu PanganPROGRAM DIPLOMA

    Institut Pertanian Bogor

  • 7/27/2019 Table Mil Std 105e

    2/19

    i

    Tables for MIL-STD-105E*)

    Page

    Table I. Sample-Size Code Letters. 1

    Table II-A. Single Sampling Plans for Normal Inspection (Master Table). 2

    Table II-B. Single Sampling Plans for Tightened Inspection (Master Table). 3

    Table II-C. Single Sampling Plans for Reduced Inspection (Master Table). 4

    Table III-A. Double Sampling Plans for Normal Inspection (Master Table). 5

    Table III-B. Double Sampling Plans for Tightened Inspection (Master Table). 6

    Table III-C. Double Sampling Plans for Reduced Inspection (Master Table). 7

    Table IV-A. Multiple Sampling Plans for Normal Inspection (Master Table). 8

    Table IV-A.(continued) 9

    Table IV-B. Multiple Sampling Plans for Tightened Inspection (Master Table). 10

    Table IV-B.(continued). 11

    Table IV-C. Multiple Sampling Plans for Reduced Inspection (Master Table). 12

    Table IV-C.(continued). 13

    Table V-A. Average Outgoing Quality Limit Factors for Normal Inspection (Single Sampling). 14

    Table V-A. Average Outgoing Quality Limit Factors for Tightened Inspection (Single Sampling). 15

    Table VIII. Limit Numbers for Reduced Inspection. 16

    *)Farnum, Nicholas R. 1994. Modern Statistical Quality Control and Improvement. Wadsworth, Inc., California.

  • 7/27/2019 Table Mil Std 105e

    3/19

    ii

    Tahapan Implementasi MIL-STD-105E

    1. TentukanAQL (Acceptable Quality Level)berdasarkan perjanjian produsen dan pelanggan.

    2. Tetapkan modus dan tingkat inspeksi (jika tidak, gunakanNormal Inspection,Level II).

    3. Tentukan ukuran lot (lot size).

    4. Gunakan tabel Sample Size Code Letters untuk memilih huruf kode yang sesuai.

    5. Tetapkan tipe prosedur pengambilan sampel : single, double, atau multiple sampling.

    6. Gunakan tabel yang berkaitan dengan prosedur pengambilan sampel terpilih (tahap 5) dan modus/tingkat inspeksi (tahap 2) untuk mendapatkan ukuran sampel

    dan angka penerimaan (Ac) serta angka penolakan (Re). Dalam kasus dimana suatu rancangan tidak ada untuk ukuran lot dan AQL-nya, hati-hati mengikuti

    tanda panah dalam tabel ke rancangan terdekat yang ada.

    7. Mulailah gunakan rancangan tersebut dan catat penerimaan dan penolakan sehingga switching rule dapat diterapkan. Jika switching dilakukan, tentukan modus

    dan tingkat dan ulangi tahap 4-6 untuk mendapatkan rancangan pengambilan sampel yang baru.

    SWITCHING RULE for MIL-STD-105E

    DariNormal ke Tightened Inspection : setelah 2 lot ditolak dari 2, 3, 4, atau 5 lot berurutan

    Dari Tightened keNormal Inspection : setelah 5 lot berurutan diterima

    DariNormal keReduced Inspection : jika (i) 10 lot berurutan diterima, dan (ii) jumlah total nonconforming items dalam 10 lot tersebut tidak melebihi batas

    pada Table VIII. Limit Numbers for Reduced Inspection., dan (iii) produksi stabil/mantap, dan (iv) disetujui oleh otoritas

    yang bertanggungjawab.

    DariReduced keNormal Inspection : jika (i) suatu lot tunggal ditolak, atau (ii) suatu lot hanya sebagian dapat diterima (dhi. jumlah nonconforming items

    diantara angka diterima dan ditolak), atau (iii) produksi menjadi tidak stabil, atau (iv) kondisi-kondisi lain yang

    menjamin bahwa inspeksi Normal dapat dilakukan.

  • 7/27/2019 Table Mil Std 105e

    4/19

    1

    Table I. Sample-Size Code Letters.

    Lot or batch size

    Special Inspection Levels General Inspection Levels

    S-1 S-2 S-3 S-4 I II III

    2 to 8

    9 to 15

    16 to 25

    A

    A

    A

    A

    A

    A

    A

    A

    B

    A

    A

    B

    A

    A

    B

    A

    B

    C

    B

    C

    D

    26 to 50

    51 to 90

    91 to 150

    A

    B

    B

    B

    B

    B

    B

    C

    C

    C

    C

    D

    C

    C

    D

    D

    E

    F

    E

    F

    G

    151 to 280

    281 to 500

    501 to 1,200

    B

    B

    C

    C

    C

    C

    D

    D

    E

    E

    E

    F

    E

    F

    G

    G

    H

    J

    H

    J

    K

    1,201 to 3,200

    3,201 to 10,000

    10,001 to 35,000

    C

    C

    C

    D

    D

    D

    E

    F

    F

    G

    G

    H

    H

    J

    K

    K

    L

    M

    L

    M

    N

    35,001 to 150,000

    150,001 to 500,000

    500,001 and over

    D

    D

    D

    E

    E

    E

    G

    G

    H

    J

    J

    K

    L

    M

    N

    N

    P

    Q

    P

    Q

    R

  • 7/27/2019 Table Mil Std 105e

    5/19

    2

    Table II - A. Single Sampling Plans for Normal Inspection (Master Table).

    Samplesizecodeletter

    Samplesize

    Acceptable Quality Levels (normal inspection)

    0.010 0.015 0.025 0.040 0.065 0.10 0.15 0.25 0.40 0.65 1.0 1.5 2.5 4.0 6.5 10 15 25 40 65 100 150 250 400 650 1000

    Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re

    A

    B

    C

    2

    3

    5 0 1

    0 1

    0 1

    1 2

    1 2

    2 3

    1 2

    2 3

    3 4

    2 3

    3 4

    5 6

    3 4

    5 6

    7 8

    5 6

    7 8

    10 11

    7 8

    10 11

    14 15

    10 11

    14 15

    21 22

    14 15

    21 22

    30 31

    21 22

    30 31

    44 45

    30 31

    44 45

    D

    E

    F

    8

    13

    20 0 1

    0 1

    0 1

    1 2

    1 2

    2 3

    1 2

    2 3

    3 4

    2 3

    3 4

    5 6

    3 4

    5 6

    7 8

    5 6

    7 8

    10 11

    7 8

    10 11

    14 15

    10 11

    14 15

    21 22

    14 15

    21 22

    21 22

    30 31

    30 31

    44 45

    44 45

    G

    H

    J

    32

    50

    80 0 1

    0 1

    0 1

    1 2

    1 2

    2 3

    1 2

    2 3

    3 4

    2 3

    3 4

    5 6

    3 4

    5 6

    7 8

    5 6

    7 8

    10 11

    7 8

    10 11

    14 15

    10 11

    14 15

    21 22

    14 15

    21 22

    21 22

    K

    L

    M

    125

    200

    315 0 1

    0 1

    0 1

    1 2

    1 2

    2 3

    1 2

    2 3

    3 4

    2 3

    3 4

    5 6

    3 4

    5 6

    7 8

    5 6

    7 8

    10 11

    7 8

    10 11

    14 15

    10 11

    14 15

    21 22

    14 15

    21 22

    21 22

    N

    P

    Q

    500

    800

    1250 0 1

    0 1

    0 1

    1 2

    1 2

    2 3

    1 2

    2 3

    3 4

    2 3

    3 4

    5 6

    3 4

    5 6

    7 8

    5 6

    7 8

    10 11

    7 8

    10 11

    14 15

    10 11

    14 15

    21 22

    14 15

    21 22

    21 22

    R 2000 1 2 2 3 3 4 5 6 7 8 10 11 14 15 21 22

    = Use first sampling plan below arrow. If sample size equals or exceeds lot or batch size, do 100 percent inspection. Ac = Acceptance number.

    = Use first sampling plan above arrow. Re = Rejection number.

  • 7/27/2019 Table Mil Std 105e

    6/19

    3

    Table II - B. Single Sampling Plans for Tightened Inspection (Master Table).

    Samplesizecodeletter

    Samplesize

    Acceptable Quality Levels (tightened inspection)

    0.010 0.015 0.025 0.040 0.065 0.10 0.15 0.25 0.40 0.65 1.0 1.5 2.5 4.0 6.5 10 15 25 40 65 100 150 250 400 650 1000

    Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re

    A

    B

    C

    2

    3

    5 0 1

    0 1

    1 2

    1 2

    2 3

    1 2

    2 3

    3 4

    2 3

    3 4

    5 6

    3 4

    5 6

    8 9

    5 6

    8 9

    12 13

    8 9

    12 13

    18 19

    12 13

    18 19

    27 28

    18 19

    27 28

    41 42

    27 28

    41 42

    D

    E

    F

    8

    13

    20 0 1

    0 1

    0 1

    1 2

    1 2

    2 3

    1 2

    2 3

    3 4

    2 3

    3 4

    5 6

    3 4

    5 6

    8 9

    5 6

    8 9

    12 13

    8 9

    12 13

    18 19

    12 13

    18 19

    18 19

    27 28

    27 28

    41 42

    41 42

    G

    H

    J

    32

    50

    80 0 1

    0 1

    0 1

    1 2

    1 2

    2 3

    1 2

    2 3

    3 4

    2 3

    3 4

    5 6

    3 4

    5 6

    8 9

    5 6

    8 9

    12 13

    8 9

    12 13

    18 19

    12 13

    18 19

    18 19

    K

    L

    M

    125

    200

    315 0 1

    0 1

    0 1

    1 2

    1 2

    2 3

    1 2

    2 3

    3 4

    2 3

    3 4

    5 6

    3 4

    5 6

    8 9

    5 6

    8 9

    12 13

    8 9

    12 13

    18 19

    12 13

    18 19

    18 19

    N

    P

    Q

    500

    800

    1250 0 1

    0 1

    0 1

    1 2

    1 2

    2 3

    1 2

    2 3

    3 4

    2 3

    3 4

    5 6

    3 4

    5 6

    8 9

    5 6

    8 9

    12 13

    8 9

    12 13

    18 19

    12 13

    18 19

    18 19

    R

    S

    2000

    3150

    0 1

    1 2

    1 2 2 3 3 4 5 6 8 9 12 13 18 19

    = Use first sampling plan below arrow. If sample size equals or exceeds lot or batch size, do 100 percent inspection. Ac = Acceptance number.= Use first sampling plan above arrow. Re = Rejection number.

  • 7/27/2019 Table Mil Std 105e

    7/19

    Table II - C. Single Sampling Plans for Reduced Inspection (Master Table).

    Samplesizecodeletter

    Samplesize

    Acceptable Quality Levels (reduced inspection)

    0.010 0.015 0.025 0.040 0.065 0.10 0.15 0.25 0.40 0.65 1.0 1.5 2.5 4.0 6.5 10 15 25 40 65 100 150 250 400 650 1000

    Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re

    A

    B

    C

    2

    2

    2 0 1

    0 1

    0 1

    0 2

    0 2

    1 3

    1 2

    1 3

    1 4

    2 3

    2 4

    2 5

    3 4

    3 5

    3 6

    5 6

    5 6

    5 8

    7 8

    7 8

    7 10

    10 11

    10 11

    10 13

    14 15

    14 15

    14 17

    21 22

    21 22

    21 24

    30 31

    30 31

    D

    E

    F

    3

    5

    8 0 1

    0 1

    0 1

    0 2

    0 2

    1 3

    0 2

    1 3

    1 4

    1 3

    1 4

    2 5

    1 4

    2 5

    3 6

    2 5

    3 6

    5 8

    3 6

    5 8

    7 10

    5 8

    7 10

    10 13

    7 10

    10 13

    10 13

    14 17

    14 17

    21 24

    21 24

    G

    H

    J

    13

    20

    32 0 1

    0 1

    0 1

    0 2

    0 2

    1 3

    0 2

    1 3

    1 4

    1 3

    1 4

    2 5

    1 4

    2 5

    3 6

    2 5

    3 6

    5 8

    3 6

    5 8

    7 10

    5 8

    7 10

    10 13

    7 10

    10 13

    10 13

    K

    L

    M

    50

    80

    125 0 1

    0 1

    0 1

    0 2

    0 2

    1 3

    0 2

    1 3

    1 4

    1 3

    1 4

    2 5

    1 4

    2 5

    3 6

    2 5

    3 6

    5 8

    3 6

    5 8

    7 10

    5 8

    7 10

    10 13

    7 10

    10 13

    10 13

    N

    P

    Q

    200

    315

    500 0 1

    0 1

    0 1

    0 2

    0 2

    1 3

    0 2

    1 3

    1 4

    1 3

    1 4

    2 5

    1 4

    2 5

    3 6

    2 5

    3 6

    5 8

    3 6

    5 8

    7 10

    5 8

    7 10

    10 13

    7 10

    10 13

    10 13

    R 800 0 2 1 3 1 4 2 5 3 6 5 8 7 10 10 13

    = Use first sampling plan below arrow. If sample size equals or exceeds lot or batch size, do 100 percent inspection. Ac = Acceptance number.

    = Use first sampling plan above arrow. Re = Rejection number.

    = If the acceptance number has been exceeded, but the rejection number has not been reached; accept the lot, but reinstate normal inspection.

  • 7/27/2019 Table Mil Std 105e

    8/19

    Table III - A. Double Sampling Plans for Normal Inspection (Master Table).

    Samplesizecodeletter

    SampleSample

    size

    Cumulative

    samplesize

    Acceptable Quality Levels (normal inspection)

    0.010 0.015 0.025 0.040 0.065 0.10 0.15 0.25 0.40 0.65 1.0 1.5 2.5 4.0 6.5 10 15 25 40 65 100 150 250 400 650 10

    Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac

    A

    B First

    Second

    2

    2

    2

    4

    0 2

    1 2

    0 3

    3 4

    1 4

    4 5

    2 5

    6 7

    3 7

    8 9

    5 9

    12 13

    7 11

    18 19

    11 16

    26 27

    17 22

    37 38

    25

    56C First

    Second

    3

    3

    3

    6

    0 2

    1 2

    0 3

    3 4

    1 4

    4 5

    2 5

    6 7

    3 7

    8 9

    5 9

    12 13

    7 11

    18 19

    11 16

    26 27

    17 22

    37 38

    25 31

    56 57

    D First

    Second

    5

    5

    5

    10

    0 2

    1 2

    0 3

    3 4

    1 4

    4 5

    2 5

    6 7

    3 7

    8 9

    5 9

    12 13

    7 11

    18 19

    11 16

    26 27

    17 22

    37 38

    25 31

    56 57

    E First

    Second

    8

    8

    8

    16

    0 2

    1 2

    0 3

    3 4

    1 4

    4 5

    2 5

    6 7

    3 7

    8 9

    5 9

    12 13

    7 11

    18 19

    11 16

    26 27

    17 22

    37 38

    25 31

    56 57

    F First

    Second

    13

    13

    13

    26

    0 2

    1 2

    0 3

    3 4

    1 4

    4 5

    2 5

    6 7

    3 7

    8 9

    5 9

    12 13

    7 11

    18 19

    11 16

    26 27

    G First

    Second

    20

    20

    20

    40

    0 2

    1 2

    0 3

    3 4

    1 4

    4 5

    2 5

    6 7

    3 7

    8 9

    5 9

    12 13

    7 11

    18 19

    11 16

    26 27

    H First

    Second

    32

    32

    32

    64

    0 2

    1 2

    0 3

    3 4

    1 4

    4 5

    2 5

    6 7

    3 7

    8 9

    5 9

    12 13

    7 11

    18 19

    11 16

    26 27

    J FirstSecond

    5050

    50100

    0 21 2

    0 33 4

    1 44 5

    2 56 7

    3 78 9

    5 912 13

    7 1118 19

    11 1626 27

    K First

    Second

    80

    80

    80

    160

    0 2

    1 2

    0 3

    3 4

    1 4

    4 5

    2 5

    6 7

    3 7

    8 9

    5 9

    12 13

    7 11

    18 19

    11 16

    26 27

    L First

    Second

    125

    125

    125

    250

    0 2

    1 2

    0 3

    3 4

    1 4

    4 5

    2 5

    6 7

    3 7

    8 9

    5 9

    12 13

    7 11

    18 19

    11 16

    26 27

    M First

    Second

    200

    200

    200

    400

    0 2

    1 2

    0 3

    3 4

    1 4

    4 5

    2 5

    6 7

    3 7

    8 9

    5 9

    12 13

    7 11

    18 19

    11 16

    26 27

    N First

    Second

    315

    315

    315

    630

    0 2

    1 2

    0 3

    3 4

    1 4

    4 5

    2 5

    6 7

    3 7

    8 9

    5 9

    12 13

    7 11

    18 19

    11 16

    26 27

    P First

    Second

    500

    500

    500

    1000

    0 2

    1 2

    0 3

    3 4

    1 4

    4 5

    2 5

    6 7

    3 7

    8 9

    5 9

    12 13

    7 11

    18 19

    11 16

    26 27

    Q First

    Second

    800

    800

    800

    1600

    0 2

    1 2

    0 3

    3 4

    1 4

    4 5

    2 5

    6 7

    3 7

    8 9

    5 9

    12 13

    7 11

    18 19

    11 16

    26 27R First

    Second

    1250

    1250

    1250

    2500

    0 2

    1 2

    0 3

    3 4

    1 4

    4 5

    2 5

    6 7

    3 7

    8 9

    5 9

    12 13

    7 11

    18 19

    11 16

    26 27

    = Use first sampling plan below arrow. If sample size equals or exceeds lot or batch size, do 100 percent inspection. Ac = Acceptance number.

    = Use first sampling plan above arrow. Re = Rejection number.

    = Use corresponding single sampling plan (or alternatively, use double sampling plan below, where available).

  • 7/27/2019 Table Mil Std 105e

    9/19

    Table III - B. Double Sampling Plans for Tightened Inspection (Master Table).

    Samplesizecodeletter

    SampleSample

    size

    Cumulative

    samplesize

    Acceptable Quality Levels (normal inspection)

    0.010 0.015 0.025 0.040 0.065 0.10 0.15 0.25 0.40 0.65 1.0 1.5 2.5 4.0 6.5 10 15 25 40 65 100 150 250 400 650 10

    Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac

    A

    B First

    Second

    2

    2

    2

    4

    0 2

    1 2

    0 3

    3 4

    1 4

    4 5

    2 5

    6 7

    3 7

    11 12

    6 10

    15 16

    9 14

    23 24

    15 20

    34 35

    23

    52

    C First

    Second

    3

    3

    3

    6

    0 2

    1 2

    0 3

    3 4

    1 4

    4 5

    2 5

    6 7

    3 7

    11 12

    6 10

    15 16

    9 14

    23 24

    15 20

    34 35

    23 29

    52 53

    D First

    Second

    5

    5

    5

    10

    0 2

    1 2

    0 3

    3 4

    1 4

    4 5

    2 5

    6 7

    3 7

    11 12

    6 10

    15 16

    9 14

    23 24

    15 20

    34 35

    23 29

    52 53

    E First

    Second

    8

    8

    8

    16

    0 2

    1 2

    0 3

    3 4

    1 4

    4 5

    2 5

    6 7

    3 7

    11 12

    6 10

    15 16

    9 14

    23 24

    15 20

    34 35

    23 29

    52 53

    F First

    Second

    13

    13

    13

    26

    0 2

    1 2

    0 3

    3 4

    1 4

    4 5

    2 5

    6 7

    3 7

    11 12

    6 10

    15 16

    9 14

    23 24

    G First

    Second

    20

    20

    20

    40

    0 2

    1 2

    0 3

    3 4

    1 4

    4 5

    2 5

    6 7

    3 7

    11 12

    6 10

    15 16

    9 14

    23 24

    H First

    Second

    32

    32

    32

    64

    0 2

    1 2

    0 3

    3 4

    1 4

    4 5

    2 5

    6 7

    3 7

    11 12

    6 10

    15 16

    9 14

    23 24

    J First

    Second

    50

    50

    50

    100

    0 2

    1 2

    0 3

    3 4

    1 4

    4 5

    2 5

    6 7

    3 7

    11 12

    6 10

    15 16

    9 14

    23 24

    K First

    Second

    80

    80

    80

    160

    0 2

    1 2

    0 3

    3 4

    1 4

    4 5

    2 5

    6 7

    3 7

    11 12

    6 10

    15 16

    9 14

    23 24

    L First

    Second

    125

    125

    125

    250

    0 2

    1 2

    0 3

    3 4

    1 4

    4 5

    2 5

    6 7

    3 7

    11 12

    6 10

    15 16

    9 14

    23 24

    M First

    Second

    200

    200

    200

    400

    0 2

    1 2

    0 3

    3 4

    1 4

    4 5

    2 5

    6 7

    3 7

    11 12

    6 10

    15 16

    9 14

    23 24

    N First

    Second

    315

    315

    315

    630

    0 2

    1 2

    0 3

    3 4

    1 4

    4 5

    2 5

    6 7

    3 7

    11 12

    6 10

    15 16

    9 14

    23 24

    P First

    Second

    500

    500

    500

    1000

    0 2

    1 2

    0 3

    3 4

    1 4

    4 5

    2 5

    6 7

    3 7

    11 12

    6 10

    15 16

    9 14

    23 24

    Q First

    Second

    800

    800

    800

    1600

    0 2

    1 2

    0 3

    3 4

    1 4

    4 5

    2 5

    6 7

    3 7

    11 12

    6 10

    15 16

    9 14

    23 24

    R First

    Second

    1250

    1250

    1250

    2500

    0 2

    1 2

    0 3

    3 4

    1 4

    4 5

    2 5

    6 7

    3 7

    11 12

    6 10

    15 16

    9 14

    23 24

    S First

    Second

    2000

    2000

    2000

    4000

    0 2

    1 2

    = Use first sampling plan below arrow. If sample size equals or exceeds lot or batch size, do 100 percent inspection. Ac = Acceptance number.

    = Use first sampling plan above arrow. Re = Rejection number. = Use corresponding single sampling plan (or alternatively, use double sampling plan below, where available).

  • 7/27/2019 Table Mil Std 105e

    10/19

    Table III - C. Double Sampling Plans for Reduced Inspection (Master Table).

    Samplesizecodeletter

    SampleSample

    size

    Cumulative

    samplesize

    Acceptable Quality Levels (reduced inspection)

    0.010 0.015 0.025 0.040 0.065 0.10 0.15 0.25 0.40 0.65 1.0 1.5 2.5 4.0 6.5 10 15 25 40 65 100 150 250 400 650 10

    Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac

    A

    B

    C

    D First

    Second

    2

    2

    2

    4

    0 2

    0 2

    0 3

    0 4

    0 4

    1 5

    0 4

    3 6

    1 5

    4 7

    2 7

    6 9

    3 8

    8 12

    5 10

    12 16

    7 12

    18 22

    11 17

    26 30

    E First

    Second

    3

    3

    3

    6

    0 2

    0 2

    0 3

    0 4

    0 4

    1 5

    0 4

    3 6

    1 5

    4 7

    2 7

    6 9

    3 8

    8 12

    5 10

    12 16

    7 12

    18 22

    11 17

    26 30

    F First

    Second

    5

    5

    5

    10

    0 2

    0 2

    0 3

    0 4

    0 4

    1 5

    0 4

    3 6

    1 5

    4 7

    2 7

    6 9

    3 8

    8 12

    5 10

    12 16

    G First

    Second

    8

    8

    8

    16

    0 2

    0 2

    0 3

    0 4

    0 4

    1 5

    0 4

    3 6

    1 5

    4 7

    2 7

    6 9

    3 8

    8 12

    5 10

    12 16

    H First

    Second

    13

    13

    13

    26

    0 2

    0 2

    0 3

    0 4

    0 4

    1 5

    0 4

    3 6

    1 5

    4 7

    2 7

    6 9

    3 8

    8 12

    5 10

    12 16

    J First

    Second

    20

    20

    20

    40

    0 2

    0 2

    0 3

    0 4

    0 4

    1 5

    0 4

    3 6

    1 5

    4 7

    2 7

    6 9

    3 8

    8 12

    5 10

    12 16

    K First

    Second

    32

    32

    32

    64

    0 2

    0 2

    0 3

    0 4

    0 4

    1 5

    0 4

    3 6

    1 5

    4 7

    2 7

    6 9

    3 8

    8 12

    5 10

    12 16

    L FirstSecond

    5050

    50100

    0 20 2

    0 30 4

    0 41 5

    0 43 6

    1 54 7

    2 76 9

    3 88 12

    5 1012 16

    M First

    Second

    80

    80

    80

    160

    0 2

    0 2

    0 3

    0 4

    0 4

    1 5

    0 4

    3 6

    1 5

    4 7

    2 7

    6 9

    3 8

    8 12

    5 10

    12 16

    N First

    Second

    125

    125

    125

    250

    0 2

    0 2

    0 3

    0 4

    0 4

    1 5

    0 4

    3 6

    1 5

    4 7

    2 7

    6 9

    3 8

    8 12

    5 10

    12 16

    P First

    Second

    200

    200

    200

    400

    0 2

    0 2

    0 3

    0 4

    0 4

    1 5

    0 4

    3 6

    1 5

    4 7

    2 7

    6 9

    3 8

    8 12

    5 10

    12 16

    Q First

    Second

    315

    315

    315

    630

    0 2

    0 2

    0 3

    0 4

    0 4

    1 5

    0 4

    3 6

    1 5

    4 7

    2 7

    6 9

    3 8

    8 12

    5 10

    12 16

    R First

    Second

    500

    500

    500

    1000

    0 2

    0 2

    0 3

    0 4

    0 4

    1 5

    0 4

    3 6

    1 5

    4 7

    2 7

    6 9

    3 8

    8 12

    5 10

    12 16

    = Use first sampling plan below arrow. If sample size equals or exceeds lot or batch size, do 100 percent inspection.

    = Use first sampling plan above arrow.

    Ac = Acceptance number.

    Re = Rejection number.

    = Use corresponding single sampling plan (or alternatively, use double sampling plan below, where available).

    = If, after the second sample, the acceptance number has been exceeded, but the rejection number has not been reached, accept the lot, but reinstate normal inspection.

  • 7/27/2019 Table Mil Std 105e

    11/19

    Table IV- A. Multiple Sampling Plans for Normal Inspection (Master Table).

    Samplesizecodeletter

    SampleSample

    size

    Cumulative

    samplesize

    Acceptable Quality Levels (normal inspection)

    0.010 0.015 0.025 0.040 0.065 0.10 0.15 0.25 0.40 0.65 1.0 1.5 2.5 4.0 6.5 10 15 25 40 65 100 150 250 400 650 10

    Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac

    ABC

    ++++++

    ++++

    ++++

    ++++

    ++++

    ++++

    ++++

    ++++

    ++++

    +

    D FirstSecondThird

    FourthFifthSixthSeventh

    222

    2222

    246

    8101214

    # 2# 20 2

    0 31 31 32 3

    # 20 30 3

    1 42 43 54 5

    # 30 31 4

    2 53 64 66 7

    # 41 52 6

    3 75 87 99 10

    0 41 63 8

    5 107 11

    10 1213 14

    0 53 86 10

    8 1311 1514 1718 19

    1 74 108 13

    12 1717 2021 2325 26

    2 97 14

    13 19

    19 2525 2931 3337 38

    4 1211 1919 27

    27 3436 4045 4753 54

    6 1617 2729 39

    40 4953 5865 6877 78

    E FirstSecondThirdFourthFifthSixthSeventh

    3333333

    36912151821

    # 2# 20 20 31 31 32 3

    # 20 30 31 42 43 54 5

    # 30 31 42 53 64 66 7

    # 41 52 63 75 87 99 10

    0 41 63 85 107 11

    10 1213 14

    0 53 86 108 13

    11 1514 1718 19

    1 74 108 13

    12 1717 2021 2325 26

    2 97 14

    13 1919 2525 2931 3337 38

    4 1211 1919 2727 3436 4045 4753 54

    6 1617 2729 3940 4953 5865 6877 78

    F FirstSecondThirdFourthFifthSixthSeventh

    5555555

    5101520253035

    # 2# 20 20 31 31 32 3

    # 20 30 31 42 43 54 5

    # 30 31 42 53 64 66 7

    # 41 52 63 75 87 99 10

    0 41 63 85 107 11

    10 1213 14

    0 53 86 108 13

    11 1514 1718 19

    1 74 108 13

    12 1717 2021 2325 26

    2 97 14

    13 1919 2525 2931 3337 38

    G FirstSecondThirdFourthFifthSixthSeventh

    8888888

    8162432404856

    # 2# 20 20 31 31 32 3

    # 20 30 31 42 43 54 5

    # 30 31 42 53 64 66 7

    # 41 52 63 75 87 99 10

    0 41 63 85 107 11

    10 1213 14

    0 53 86 108 13

    11 1514 1718 19

    1 74 108 13

    12 1717 2021 2325 26

    2 97 14

    13 1919 2525 2931 3337 38

    H FirstSecondThirdFourthFifthSixthSeventh

    13131313131313

    13263952657891

    # 2# 20 20 31 31 32 3

    # 20 30 31 42 43 54 5

    # 30 31 42 53 64 66 7

    # 41 52 63 75 87 99 10

    0 41 63 85 107 11

    10 1213 14

    0 53 86 108 13

    11 1514 1718 19

    1 74 108 13

    12 1717 2021 2325 26

    2 97 14

    13 1919 2525 2931 3337 38

    J FirstSecondThird

    FourthFifthSixthSeventh

    202020

    20202020

    204060

    80100120140

    # 2# 20 2

    0 31 31 32 3

    # 20 30 3

    1 42 43 54 5

    # 30 31 4

    2 53 64 66 7

    # 41 52 6

    3 75 87 99 10

    0 41 63 8

    5 107 1110 1213 14

    0 53 86 10

    8 1311 1514 1718 19

    1 74 108 13

    12 1717 2021 2325 26

    2 97 14

    13 19

    19 2525 2931 3337 38

    = Use first sampling plan below arrow (refer to continuation of table on following page, when necessary). If sample size equals or exceeds lot or batch size, do 100 percent inspection. = Use first sampling plan above ar

    = Use corresponding single sampling plan (or alternatively, use double sampling plan below, where available). Ac = Acceptance number. Re = Rejection number.++ = Use corresponding double sampling plan (or alternatively, use multiple sampling plan below, where available). # = Acceptance not permitted at this sample size.

  • 7/27/2019 Table Mil Std 105e

    12/19

    Table IV- A. (continued).Sample

    sizecodeletter

    SampleSample

    size

    Cumulative

    samplesize

    Acceptable Quality Levels (norm

    0.010 0.015 0.025 0.040 0.065 0.10 0.15 0.25 0.40 0.65 1.0 1.5 2.5 4.0

    Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re A

    K FirstSecond

    ThirdFourthFifthSixthSeventh

    3232

    3232323232

    3264

    96128160192224

    # 2# 2

    0 20 31 31 32 3

    # 20 3

    0 31 42 43 54 5

    # 30 3

    1 42 53 64 66 7

    # 41 5

    2 63 75 87 99 10

    0 41 6

    3 85 107 11

    10 1213 14

    0 53 8

    6 108 1311 1514 1718 19

    1122

    L FirstSecondThirdFourthFifthSixthSeventh

    50505050505050

    50100150200250300350

    # 2# 20 20 31 31 32 3

    # 20 30 31 42 43 54 5

    # 30 31 42 53 64 66 7

    # 41 52 63 75 87 99 10

    0 41 63 85 107 11

    10 1213 14

    0 53 86 108 13

    11 1514 1718 19

    1 74 108 13

    12 1717 2021 2325 26

    11233

    M FirstSecondThirdFourthFifthSixthSeventh

    80808080808080

    80160240320400480560

    # 2# 20 20 31 31 32 3

    # 20 30 31 42 43 54 5

    # 30 31 42 53 64 66 7

    # 41 52 63 75 87 99 10

    0 41 63 85 107 11

    10 1213 14

    0 53 86 108 13

    11 1514 1718 19

    1 74 108 13

    12 1717 2021 2325 26

    2 97 14

    13 1919 2525 2931 3337 38

    N FirstSecondThirdFourth

    FifthSixthSeventh

    125125125125

    125125125

    125250375500

    625750875

    # 2# 20 20 3

    1 31 32 3

    # 20 30 31 4

    2 43 54 5

    # 30 31 42 5

    3 64 66 7

    # 41 52 63 7

    5 87 99 10

    0 41 63 85 10

    7 1110 1213 14

    0 53 86 108 13

    11 1514 1718 19

    1 74 108 13

    12 17

    17 2021 2325 26

    2 97 14

    13 1919 25

    25 2931 3337 38

    P FirstSecondThirdFourthFifthSixth

    200200200200200200

    20040060080010001200

    # 2# 20 20 31 31 3

    # 20 30 31 42 43 5

    # 30 31 42 53 64 6

    # 41 52 63 75 87 9

    0 41 63 85 107 11

    10 12

    0 53 86 108 13

    11 1514 17

    1 74 108 13

    12 1717 2021 23

    2 97 14

    13 1919 2525 2931 33

  • 7/27/2019 Table Mil Std 105e

    13/19

    Table IV- B. Multiple Sampling Plans for Tightened Inspection (Master Table).

    Samplesizecodeletter

    SampleSample

    size

    Cumulative

    samplesize

    Acceptable Quality Levels (tightened inspection)

    0.010 0.015 0.025 0.040 0.065 0.10 0.15 0.25 0.40 0.65 1.0 1.5 2.5 4.0 6.5 10 15 25 40 65 100 150 250 400 650 10

    Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac

    ABC

    ++

    ++++

    ++++

    ++++

    ++++

    ++++

    ++++

    ++++

    ++++

    +

    D FirstSecondThirdFourthFifthSixthSeventh

    2222222

    2468101214

    # 2# 20 20 31 31 32 3

    # 20 30 31 42 43 54 5

    # 30 31 42 53 64 66 7

    # 41 52 63 75 87 99 10

    0 42 74 96 119 12

    12 1414 15

    0 63 97 12

    10 1514 1718 2021 22

    1 86 12

    11 1716 2222 2527 2932 33

    3 1010 1717 2424 3132 3740 4348 49

    6 1516 2526 3637 4649 5561 6472 73

    E FirstSecondThirdFourthFifthSixthSeventh

    3333333

    36912151821

    # 2# 20 20 31 31 32 3

    # 20 30 31 42 43 54 5

    # 30 31 42 53 64 66 7

    # 41 52 63 75 87 99 10

    0 42 74 96 119 12

    12 1414 15

    0 63 97 12

    10 1514 1718 2021 22

    1 86 12

    11 1716 2222 2527 2932 33

    3 1010 1717 2424 3132 3740 4348 49

    6 1516 2526 3637 4649 5561 6472 73

    F FirstSecondThirdFourthFifthSixthSeventh

    5555555

    5101520253035

    # 2# 20 20 31 31 32 3

    # 20 30 31 42 43 54 5

    # 30 41 42 53 64 66 7

    # 41 52 63 75 87 99 10

    0 42 74 96 119 12

    12 1414 15

    0 63 97 12

    10 1514 1718 2021 22

    1 86 12

    11 1716 2222 2527 2932 33

    G FirstSecondThirdFourthFifthSixthSeventh

    8888888

    8162432404856

    # 2# 20 20 31 31 32 3

    # 20 30 31 42 43 54 5

    # 30 41 42 53 64 66 7

    # 41 52 63 75 87 99 10

    0 42 74 96 119 12

    12 1414 15

    0 63 97 12

    10 1514 1718 2021 22

    1 86 12

    11 1716 2222 2527 2932 33

    H FirstSecondThirdFourthFifthSixthSeventh

    13131313131313

    13263952657891

    # 2# 20 20 31 31 32 3

    # 20 30 31 42 43 54 5

    # 30 41 42 53 64 66 7

    # 41 52 63 75 87 99 10

    0 42 74 96 119 12

    12 1414 15

    0 63 97 12

    10 1514 1718 2021 22

    1 86 12

    11 1716 2222 2527 2932 33

    J FirstSecondThirdFourth

    FifthSixthSeventh

    20202020

    202020

    20406080

    100120140

    # 2# 20 20 3

    1 31 32 3

    # 20 30 31 4

    2 43 54 5

    # 30 41 42 5

    3 64 66 7

    # 41 52 63 7

    5 87 99 10

    0 42 74 96 11

    9 1212 1414 15

    0 63 97 12

    10 15

    14 1718 2021 22

    1 86 12

    11 1716 22

    22 2527 2932 33

    = Use first sampling plan below arrow (refer to continuation of table on following page, when necessary). If sample size equals or exceeds lot or batch size, do 100 percent inspection. = Use first sampling plan above ar

    = Use corresponding single sampling plan (or alternatively, use double sampling plan below, where available). Ac = Acceptance number. Re = Rejection number.++ = Use corresponding double sampling plan (or alternatively, use multiple sampling plan below, where available). # = Acceptance not permittedat this sample size.

  • 7/27/2019 Table Mil Std 105e

    14/19

    Table IV- B. (continued).

    Samplesizecodeletter

    SampleSample

    size

    Cumulative

    samplesize

    Acceptable Quality Levels (tightened inspection)

    0.010 0.015 0.025 0.040 0.065 0.10 0.15 0.25 0.40 0.65 1.0 1.5 2.5 4.0 6.5 10 15 25 40 65 100 150 250 400 650 10

    Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac

    K FirstSecondThirdFourthFifthSixthSeventh

    32323232323232

    326496128160192224

    # 2# 20 20 31 31 32 3

    # 20 30 31 42 43 54 5

    # 30 41 42 53 64 66 7

    # 41 52 63 75 87 99 10

    0 42 74 96 119 12

    12 1414 15

    0 63 97 12

    10 1514 1718 2021 22

    1 86 12

    11 1716 2222 2527 2932 33

    L FirstSecondThirdFourthFifthSixthSeventh

    50505050505050

    50100150200250300350

    # 2# 20 20 31 31 32 3

    # 20 30 31 42 43 54 5

    # 30 41 42 53 64 66 7

    # 41 52 63 75 87 99 10

    0 42 74 96 119 12

    12 1414 15

    0 63 97 12

    10 1514 1718 2021 22

    1 86 12

    11 1716 2222 2527 2932 33

    M FirstSecondThirdFourthFifthSixthSeventh

    80808080808080

    80160240320400480560

    # 2# 20 20 31 31 32 3

    # 20 30 31 42 43 54 5

    # 30 41 42 53 64 66 7

    # 41 52 63 75 87 99 10

    0 42 74 96 119 12

    12 1414 15

    0 63 97 12

    10 1514 1718 2021 22

    1 86 12

    11 1716 2222 2527 2932 33

    N FirstSecondThirdFourthFifthSixthSeventh

    125125125125125125125

    125250375500625750875

    # 2# 20 20 31 31 32 3

    # 20 30 31 42 43 54 5

    # 30 41 42 53 64 66 7

    # 41 52 63 75 87 99 10

    0 42 74 96 119 12

    12 1414 15

    0 63 97 12

    10 1514 1718 2021 22

    1 86 12

    11 1716 2222 2527 2932 33

    P FirstSecondThirdFourthFifthSixthSeventh

    200200200200200200200

    200400600800

    100012001400

    # 2# 20 20 31 31 32 3

    # 20 30 31 42 43 54 5

    # 30 41 42 53 64 66 7

    # 41 52 63 75 87 99 10

    0 42 74 96 119 12

    12 1414 15

    0 63 97 12

    10 1514 1718 2021 22

    1 86 12

    11 1716 2222 2527 2932 33

    Q FirstSecondThirdFourthFifthSixthSeventh

    315315315315315315315

    315630945

    1260157518902205

    # 2# 20 20 31 31 32 3

    # 20 30 31 42 43 54 5

    # 30 41 42 53 64 66 7

    # 41 52 63 75 87 99 10

    0 42 74 96 119 12

    12 1414 15

    0 63 97 12

    10 1514 1718 2021 22

    1 86 12

    11 1716 2222 2527 2932 33

    R FirstSecondThirdFourthFifth

    SixthSeventh

    500500500500500

    500500

    5001000150020002500

    30003500

    # 2# 20 20 31 3

    1 32 3

    # 20 30 31 42 4

    3 54 5

    # 30 41 42 53 6

    4 66 7

    # 41 52 63 75 8

    7 99 10

    0 42 74 96 119 12

    12 1414 15

    0 63 97 12

    10 1514 17

    18 2021 22

    1 86 12

    11 1716 2222 25

    27 2932 33

    S FirstSecondThirdFourthFifthSixthSeventh

    800800800800800800800

    800160024003200400048005600

    # 2# 20 20 31 31 32 3

  • 7/27/2019 Table Mil Std 105e

    15/19

    Table IV- C. Multiple Sampling Plans for Reduced Inspection (Master Table).

    Samplesizecodeletter

    SampleSample

    size

    Cumulative

    samplesize

    Acceptable Quality Levels (reduced inspection)

    0.010 0.015 0.025 0.040 0.065 0.10 0.15 0.25 0.40 0.65 1.0 1.5 2.5 4.0 6.5 10 15 25 40 65 100 150 250 400 650 10

    Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac

    ABCDE

    ++

    ++++

    ++++

    ++++

    ++++

    ++++

    ++++

    ++++

    ++++

    ++++

    ++

    F FirstSecondThirdFourthFifthSixthSeventh

    2222222

    2468101214

    # 2# 20 20 30 30 31 3

    # 2# 30 30 40 41 51 5

    # 3# 30 40 51 61 62 7

    # 30 40 51 62 73 74 8

    # 40 51 62 73 84 96 10

    # 41 62 83 105 117 129 14

    0 51 73 95 127 13

    10 1513 17

    0 63 96 128 15

    11 1714 2018 22

    G FirstSecondThirdFourthFifthSixthSeventh

    3333333

    36912151821

    # 2# 20 20 30 30 31 3

    # 2# 30 30 40 41 51 5

    # 3# 30 40 51 61 62 7

    # 30 40 51 62 73 74 8

    # 40 51 62 73 84 96 10

    # 41 62 83 105 117 129 14

    0 51 73 95 127 13

    10 1513 17

    0 63 96 128 15

    11 1714 2018 22

    H FirstSecondThirdFourthFifthSixthSeventh

    5555555

    5101520253035

    # 2# 20 20 30 30 31 3

    # 2# 30 30 40 41 51 5

    # 3# 30 40 51 61 62 7

    # 30 40 51 62 73 74 8

    # 40 51 62 73 84 96 10

    # 41 62 83 105 117 129 14

    0 51 73 95 127 13

    10 1513 17

    0 63 96 128 15

    11 1714 2018 22

    J FirstSecondThirdFourthFifthSixthSeventh

    8888888

    8162432404856

    # 2# 20 20 30 30 31 3

    # 2# 30 30 40 41 51 5

    # 3# 30 40 51 61 62 7

    # 30 40 51 62 73 74 8

    # 40 51 62 73 84 96 10

    # 41 62 83 105 117 129 14

    0 51 73 95 127 13

    10 1513 17

    0 63 96 128 15

    11 1714 2018 22

    K FirstSecondThirdFourthFifth

    SixthSeventh

    1313131313

    1313

    1326395265

    7891

    # 2# 20 20 30 3

    0 31 3

    # 2# 30 30 40 4

    1 51 5

    # 3# 30 40 51 6

    1 62 7

    # 30 40 51 62 7

    3 74 8

    # 40 51 62 73 8

    4 96 10

    # 41 62 83 105 11

    7 129 14

    0 51 73 95 127 13

    10 1513 17

    0 63 96 128 15

    11 17

    14 2018 22

    = Use first sampling plan below arrow (refer to continuation of table on following page, when necessary). If sample size equals or exceeds lot or batch size, do 100 percent inspection. = Use first sampling plan above ar

    = Use corresponding single sampling plan (or alternatively, use double sampling plan below, where available). Ac = Acceptance number. Re = Rejection number.++ = Use corresponding double sampling plan (or alternatively, use multiple sampling plan below, where available). # = Acceptance not permitted at this sample size. = If, after the final sample, the acceptance number has been exceeded but the rejection number has not been reached, accept the lot but reinstate normal inspection.

  • 7/27/2019 Table Mil Std 105e

    16/19

    Table IV- C. (continued).

    Samplesizecodeletter

    SampleSample

    size

    Cumulative

    samplesize

    Acceptable Quality Levels (reduced inspection)

    0.010 0.015 0.025 0.040 0.065 0.10 0.15 0.25 0.40 0.65 1.0 1.5 2.5 4.0 6.5 10 15 25 40 65 100 150 250 400 650 10

    Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac

    L FirstSecondThirdFourthFifthSixthSeventh

    20202020202020

    20406080

    100120140

    # 2# 20 20 30 30 31 3

    # 2# 30 30 40 41 51 5

    # 3# 30 40 51 61 62 7

    # 30 40 51 62 73 74 8

    # 40 51 62 73 84 96 10

    # 41 62 83 105 117 129 14

    0 51 73 95 127 13

    10 1513 17

    0 63 96 128 15

    11 1714 2018 22

    M FirstSecondThirdFourthFifthSixthSeventh

    32323232323232

    326496

    128160192224

    # 2# 20 20 30 30 31 3

    # 2# 30 30 40 41 51 5

    # 3# 30 40 51 61 62 7

    # 30 40 51 62 73 74 8

    # 40 51 62 73 84 96 10

    # 41 62 83 105 117 129 14

    0 51 73 95 127 13

    10 1513 17

    0 63 96 128 15

    11 1714 2018 22

    N FirstSecondThirdFourthFifthSixthSeventh

    50505050505050

    50100150200250300350

    # 2# 20 20 30 30 31 3

    # 2# 30 30 40 41 51 5

    # 3# 30 40 51 61 62 7

    # 30 40 51 62 73 74 8

    # 40 51 62 73 84 96 10

    # 41 62 83 105 117 129 14

    0 51 73 95 127 13

    10 1513 17

    0 63 96 128 15

    11 1714 2018 22

    P FirstSecond

    ThirdFourthFifthSixthSeventh

    8080

    8080808080

    80160

    240320400480560

    # 2# 2

    0 20 30 30 31 3

    # 2# 3

    0 30 40 41 51 5

    # 3# 3

    0 40 51 61 62 7

    # 30 4

    0 51 62 73 74 8

    # 40 5

    1 62 73 84 96 10

    # 41 6

    2 83 105 117 129 14

    0 51 7

    3 95 127 13

    10 1513 17

    0 63 9

    6 128 15

    11 1714 2018 22

    Q FirstSecondThirdFourthFifthSixthSeventh

    125125125125125125125

    125250375500625750875

    # 2# 20 20 30 30 31 3

    # 2# 30 30 40 41 51 5

    # 3# 30 40 51 61 62 7

    # 30 40 51 62 73 74 8

    # 40 51 62 73 84 96 10

    # 41 62 83 105 117 129 14

    0 51 73 95 127 13

    10 1513 17

    0 63 96 128 15

    11 1714 2018 22

    R FirstSecondThirdFourthFifth

    SixthSeventh

    200200200200200

    200200

    200400600800

    1000

    12001400

    # 2# 20 20 30 3

    0 31 3

    # 2# 30 30 40 4

    1 51 5

    # 3# 30 40 51 6

    1 62 7

    # 30 40 51 62 7

    3 74 8

    # 40 51 62 73 8

    4 96 10

    # 41 62 83 105 11

    7 129 14

    0 51 73 95 127 13

    10 1513 17

    0 63 96 128 15

    11 17

    14 2018 22

    = Use first sampling plan below arrow (refer to continuation of table on following page, when necessary). If sample size equals or exceeds lot or batch size, do 100 percent inspection. = Use first sampling plan above ar

    = Use corresponding single sampling plan (or alternatively, use double sampling plan below, where available). Ac = Acceptance number. Re = Rejection number.++ = Use corresponding double sampling plan (or alternatively, use multiple sampling plan below, where available). # = Acceptance not permitted at this sample size. = If, after the final sample, the acceptance number has been exceeded but the rejection number has not been reached, accept the lot but reinstate normal inspection.

  • 7/27/2019 Table Mil Std 105e

    17/19

    Table V-A. Average Outgoing Quality Limit Factors for Normal Inspection (Single Sampling) *

    CodeLetter

    Samplesize

    Acceptable Quality Level

    0.010 0.015 0.025 0.040 0.065 0.10 0.15 0.25 0.40 0.65 1.0 1.5 2.5 4.0 6.5 10 15 25 40 65 100 150 250 400 650 1

    A

    B

    C

    2

    3

    5 7.4

    12

    18

    17

    28

    27

    42

    46

    39

    69

    65

    63

    97

    110

    90

    160

    150

    130

    220

    220

    190

    330

    310

    290

    470

    490

    430

    730

    720

    660

    1

    1

    D

    E

    F

    8

    13

    20 1.8

    2.8

    4.6

    4.2

    6.5

    6.9

    11

    11

    9.7

    17

    15

    16

    24

    24

    22

    40

    34

    33

    56

    50

    47

    82

    72

    73

    120

    110

    180

    170

    270

    250

    410

    G

    H

    J

    32

    50

    80 0.46

    0.74

    1.2

    1.1

    1.7

    1.7

    2.6

    2.7

    2.4

    4.3

    3.9

    4.0

    6.1

    6.3

    5.6

    9.9

    9.0

    8.2

    14

    13

    12

    21

    19

    18

    29

    29

    46

    K

    L

    M

    125

    200

    315 0.12

    0.18

    0.29

    0.27

    0.42

    0.44

    0.67

    0.69

    0.62

    1.1

    0.97

    1.00

    1.6

    1.6

    1.4

    2.5

    2.2

    2.1

    3.6

    3.3

    3.0

    5.2

    4.7

    4.7

    7.5

    7.3

    12

    N

    P

    Q

    500

    800

    1250 0.029

    0.046

    0.074

    0.067

    0.11

    0.11

    0.17

    0.17

    0.16

    0.27

    0.24

    0.25

    0.39

    0.40

    0.36

    0.63

    0.56

    0.52

    0.90

    0.82

    0.75

    1.3

    1.2

    1.2

    1.9

    1.8

    2.9

    R 2000 0.042 0.069 0.097 0.16 0.22 0.33 0.47 0.73

    * Note: For the exact AOQL, the above volume must be multiplied by

    sizeBatchorLot

    sizeSample1

  • 7/27/2019 Table Mil Std 105e

    18/19

    Table V-B. Average Outgoing Quality Limit Factors for Tightened Inspection (Single Sampling) *

    CodeLetter

    Samplesize

    Acceptable Quality Level

    0.010 0.015 0.025 0.040 0.065 0.10 0.15 0.25 0.40 0.65 1.0 1.5 2.5 4.0 6.5 10 15 25 40 65 100 150 250 400 650 1

    A

    B

    C

    2

    3

    5 7.4

    12

    17

    28

    27

    42

    46

    39

    69

    65

    63

    97

    110

    100

    160

    170

    160

    260

    270

    250

    400

    410

    390

    620

    650

    610

    1

    D

    E

    F

    8

    13

    20 1.8

    2.8

    4.6

    4.2

    6.5

    6.9

    11

    11

    9.7

    17

    15

    16

    24

    24

    26

    40

    40

    40

    64

    61

    62

    99

    95

    160

    150

    240

    240

    380

    G

    H

    J

    32

    50

    80 0.46

    0.74

    1.2

    1.1

    1.7

    1.7

    2.6

    2.7

    2.4

    4.3

    3.9

    4.0

    6.1

    6.3

    6.4

    9.9

    10

    9.9

    16

    16

    16

    25

    25

    39

    K

    L

    M

    125

    200

    315 0.12

    0.18

    0.29

    0.27

    0.42

    0.44

    0.67

    0.69

    0.62

    1.1

    0.97

    1.0

    1.6

    1.6

    1.6

    2.5

    2.6

    2.5

    4.1

    4.0

    3.9

    6.4

    6.2

    9.9

    N

    P

    Q

    500

    800

    1250 0.029

    0.046

    0.074

    0.067

    0.11

    0.11

    0.17

    0.17

    0.16

    0.27

    0.24

    0.25

    0.39

    0.40

    0.41

    0.63

    0.64

    0.64

    1.0

    0.99

    0.99

    1.6

    1.6

    2.5

    R

    S

    2000

    3150

    0.018

    0.027

    0.042 0.069 0.097 0.16 0.26 0.40 0.62

    * Note: For the exact AOQL, the above volume must be multiplied by

    sizeBatchorLot

    sizeSample1

  • 7/27/2019 Table Mil Std 105e

    19/19

    Table VIII. Limit Numbers for Reduced Inspection.

    Number ofsample units

    Acceptable Quality Level

    from last 10lots or batches 0.010 0.015 0.025 0.040 0.065 0.10 0.15 0.25 0.40 0.65 1.0 1.5 2.5 4.0 6.5 10 15 25 40 65 100 150 250 400 650 1

    20- 2930- 49

    50- 79

    0

    0

    0

    00

    2

    01

    3

    23

    7

    47

    14

    813

    25

    1422

    40

    2236

    63

    4063

    110

    68105

    181

    115178

    301

    12

    80- 129130 - 199200 - 319

    0

    00

    002

    024

    248

    4714

    71322

    142540

    244268

    4272115

    68115181

    105177277

    181301471

    297490

    320- 499500- 799800 - 1249

    0

    00

    002

    024

    137

    4714

    81424

    142542

    244068

    3963105

    68110181

    113181

    189

    1250- 19992000- 31493150- 4999

    0

    00

    001

    024

    248

    4814

    71424

    132238

    244067

    4068111

    69115186

    110181

    169

    5000- 79998000- 1249912500- 19999

    0

    00

    002

    024

    247

    3713

    71424

    142440

    254269

    4068110

    63105169

    110181

    181

    20000- 3149931500- 4999950000 & over

    002

    013

    247

    4814

    81425

    142440

    223863

    4067110

    68111181

    115186301

    181

    Denotes that the number of sample units from the last ten lots or batches is not sufficient for reduced inspection for this AQL. In this instance more than ten lots or batches may be used for the calculation, provided that the lots