35
TECH system Type 288-SAF For single servo actuator operation Instructions for installation and use

TECH system Type 288-SAFadmin.linak.as/corporate/pdf/english/user manual/thirdparty/tech-system... · TECH-system Type 288-SAF is comprised of a motor control unit and an actuator

  • Upload
    others

  • View
    9

  • Download
    1

Embed Size (px)

Citation preview

Page 1: TECH system Type 288-SAFadmin.linak.as/corporate/pdf/english/user manual/thirdparty/tech-system... · TECH-system Type 288-SAF is comprised of a motor control unit and an actuator

TECH system Type 288-SAF

For single servo actuator operation Instructions for installation and use

Page 2: TECH system Type 288-SAFadmin.linak.as/corporate/pdf/english/user manual/thirdparty/tech-system... · TECH-system Type 288-SAF is comprised of a motor control unit and an actuator

Instruction Manual for TECH system type 288-SAF

_______________________________________________________________________________________ Page 2 of 35 jan. 2019 ver. 06

LINAK Danmark A/S - Mønstedsvej 9- DK-8600 Silkeborg -Tel.: +45 86803611 - www.linak.dk

Foreword Dear machine fitter, Thank you for choosing an actuator system from LINAK®. LINAK systems consist of hi-tech products based on many years of experience in the development and manufacture of actuators, electric control boxes, control systems and chargers. TECH systems comprise LINAK actuators and a motor control unit developed and produced by third party manufacturers. The function and operational reliability of TECH systems have been tried and tested in a wide range of situations. In addition, we continuously improve our products and systems so as to accommodate customer requirements. This Instruction Manual describes how a LINAK TECH system must be installed, connected and operated in order to ensure a problem-free, user-friendly final product. Before our products leave the factory, they are subjected to comprehensive function and quality tests. In the unlikely event that you experience problems with your systems, please call LINAK Danmark A/S on (+45) 86 80 36 11 LINAK provides a warranty on all its products and systems. However, this warranty is issued on condition that the product is used in accordance with the specifications, that maintenance is performed correctly, and that any repairs are carried out at a workshop that is authorised to repair LINAK products. Any alterations to the installation and use of LINAK systems may affect their operability and durability. The products must not be opened by unauthorised persons. LINAK Danmark A/S Mønstedsvej 9 DK-8600 Silkeborg

Page 3: TECH system Type 288-SAFadmin.linak.as/corporate/pdf/english/user manual/thirdparty/tech-system... · TECH-system Type 288-SAF is comprised of a motor control unit and an actuator

Instruction Manual for TECH system type 288-SAF

_______________________________________________________________________________________ Page 3 of 35 jan. 2019 ver. 06

LINAK Danmark A/S - Mønstedsvej 9- DK-8600 Silkeborg -Tel.: +45 86803611 - www.linak.dk

Important information Important information about LINAK products is presented under the following headers:

Warning! Failure to comply with these instructions may result in accidents, leading to serious personal injury.

NB! Failure to comply with these instructions may result in damage to or destruction of the product.

Warranty The LINAK warranty covers manufacturing faults in the products, calculated from the date of production. For additional information about the warranty period, contact LINAK Danmark A/S. The warranty is limited to the value of the LINAK product. The LINAK warranty is only valid if the system is unopened and has been used correctly. The control box and control unit must not be subjected to violent handling, as this will void the warranty. Safety instructions Please read the following safety information carefully. Everyone who is to connect, install or use the system must have received the necessary information and must have access to this Instruction Manual. LINAK recommends that the actuator is used for push applications, rather than pull applications. It is essential that everyone who is to connect, assemble or operate the systems receives the necessary information and has access to this Instruction Manual. Before fitting, removal or troubleshooting:

• Stop the actuator. • Disconnect the power supply or remove the mains plug from the socket. • Relieve the actuator of any load that may be released during the work.

Before start-up:

• Make sure that the system has been installed as described in this Instruction Manual. • Make sure that the supply voltage to the motor control unit is correct before connecting the

system to the power supply • System connection. The individual parts must be connected before the motor control unit is

connected to the mains power. During operation:

• If the motor control unit emits unusual sounds or smells, disconnect the mains power and any external battery.

• Make sure that the cables are not damaged. • Disconnect the mains cable to mobile equipment before it is moved. • The products are suitable for use both indoors and outdoors. However, you should always

check that the individual products have the appropriate IP sealing class. (see product label)

Page 4: TECH system Type 288-SAFadmin.linak.as/corporate/pdf/english/user manual/thirdparty/tech-system... · TECH-system Type 288-SAF is comprised of a motor control unit and an actuator

Instruction Manual for TECH system type 288-SAF

_______________________________________________________________________________________ Page 4 of 35 jan. 2019 ver. 06

LINAK Danmark A/S - Mønstedsvej 9- DK-8600 Silkeborg -Tel.: +45 86803611 - www.linak.dk

Warning! The following applies if the actuator is used to apply tension in a machine that carries a risk of personal injury: As the manufacturer of the final machine, you are responsible for implementing suitable safety measures to prevent the risk of personal injury in the event of actuator failure.

Warning!

Please note that in all machines in which an actuator is to be involved, steps must be taken to prevent personal injury – such as the risk of crushing fingers.

Warning! The plastic components in the system cannot withstand the effects of cutting oil. Classification: The equipment is not suitable for use in the immediate vicinity of a flammable, anaesthetic mixture containing air, oxygen or laughing gas (nitrous oxide).

Environmental conditions

Page 5: TECH system Type 288-SAFadmin.linak.as/corporate/pdf/english/user manual/thirdparty/tech-system... · TECH-system Type 288-SAF is comprised of a motor control unit and an actuator

Instruction Manual for TECH system type 288-SAF

_______________________________________________________________________________________ Page 5 of 35 jan. 2019 ver. 06

LINAK Danmark A/S - Mønstedsvej 9- DK-8600 Silkeborg -Tel.: +45 86803611 - www.linak.dk

Table of contents.

Foreword ................................................................................................................................................ 2 Important information ........................................................................................................................... 3 Warranty ................................................................................................................................................. 3 Safety instructions ................................................................................................................................ 3

Environmental conditions .................................................................................................................... 4 Table of contents. .................................................................................................................................. 5 Technical data........................................................................................................................................ 6

Description of the system .................................................................................................................... 6 Dimensions ......................................................................................................................................... 8 Data plate and labelling .................................................................................................................... 10 Declaration of Incorporation .............................................................................................................. 11

Connection and installation ............................................................................................................... 12 Fitting the motor control unit ............................................................................................................. 12 Connection of the motor control unit ................................................................................................. 15 Installing the actuators ...................................................................................................................... 16 Connection of LINAK actuators ......................................................................................................... 17 Connection diagram for LINAK actuators ......................................................................................... 19

LA12 potentiometer ...................................................................................................................... 20 LA12 Hall potentiometer ............................................................................................................... 20 LA30/32 potentiometer ................................................................................................................. 20 LA23 Hall potentiometer ............................................................................................................... 21 LA35 Hall potentiometer ............................................................................................................... 21 LA36 Hall potentiometer ............................................................................................................... 21 Connection diagram for service/reset button ................................................................................ 22

Parameter settings .............................................................................................................................. 23 Portable serial interface handset TR-EM-236 ................................................................................... 23 Parameters ........................................................................................................................................ 24

Explanation of parameters ............................................................................................................ 26 Start/operation ..................................................................................................................................... 31

Appropriate use: ................................................................................................................................ 31 Inappropriate use: ............................................................................................................................. 31

Maintenance ......................................................................................................................................... 31 Reading monitoring values ............................................................................................................... 32

Explanation of monitoring values .................................................................................................. 32 Service operation .......................................................................................................................... 32

Troubleshooting .................................................................................................................................. 33 Reading errors .................................................................................................................................. 33 To reset errors ................................................................................................................................... 33

Key to symbols .................................................................................................................................... 34 Disposal of LINAK products ............................................................................................................... 35

Page 6: TECH system Type 288-SAFadmin.linak.as/corporate/pdf/english/user manual/thirdparty/tech-system... · TECH-system Type 288-SAF is comprised of a motor control unit and an actuator

Instruction Manual for TECH system type 288-SAF

_______________________________________________________________________________________ Page 6 of 35 jan. 2019 ver. 06

LINAK Danmark A/S - Mønstedsvej 9- DK-8600 Silkeborg -Tel.: +45 86803611 - www.linak.dk

Technical data TECH-system Type 288-SAF is comprised of a motor control unit and an actuator. You can choose between 6 different types of actuator.

Description of the system TECH-system Type 288-SAF is designed for industrial applications and machines, such as ventilation, transportation systems, agricultural machinery, etc. The system is a single actuator system with a servo function, designed for incorporation into machinery or ventilation systems, in order to perform functions in connection with automated regulation, adjustment, dosing, coupling, reversal, etc. The actuator spindle position (stroke length) is determined by a signal sent either from a mechanical, manually operated potentiometer, joystick or PLC. Using 24 adjustable parameters, the TR-EM-288-SAF motor control unit can be set up to operate with several different types of actuator and input logic, as well as the actuator's pattern of movement. The parameters can only be changed using a TR-EM-236 programming interface. Changes are usually made before the complete machine is commissioned and when it is subsequently readjusted.

Page 7: TECH system Type 288-SAFadmin.linak.as/corporate/pdf/english/user manual/thirdparty/tech-system... · TECH-system Type 288-SAF is comprised of a motor control unit and an actuator

Instruction Manual for TECH system type 288-SAF

_______________________________________________________________________________________ Page 7 of 35 jan. 2019 ver. 06

LINAK Danmark A/S - Mønstedsvej 9- DK-8600 Silkeborg -Tel.: +45 86803611 - www.linak.dk

Motor control unit: (pos.1) Type designation: TR-EM-288-SAF Actuator connection: 1 actuator Actuator power limit: 15 A duty cycle 100% 30 A at start Actuator voltage: 24 V DC Supply voltage to PCB: 10–35 V DC smoothed voltage Power limit, setting: 0.1-20 A: Ramp times (start/stop): 0-5 seconds PWM frequency: 2 kHz Controller input: 0-5.5 V; 0-11 V; 0...20 mA Operating temperature (Ta): -40-60°C Four versions of the motor control unit are available:

1. Separate PCB: Order no.: TR-EM-288-SAF 2. PCB fitted in box: Order no.: TR-EM-288-SAF-H 3. PCB mounted on DIN rail for panel mounting: Order no.: TR-EM-288-SAF-R 4. PCB fitted in box with power supply: Order no.: TR-EM-288-SAF-T-230

Actuator (pos.3) The system is compatible with the following LINAK actuators: All of them with either potentiometer response or Hall potentiometer:

• Actuator LA12 • Actuator LA23 • Actuator LA30 • Actuator LA32 • Actuator LA35 • Actuator LA36

(see the appropriate product data sheets for additional information)

Operation: (pos.2) The TECH-288-SAF actuator system can be operated in two different ways, depending on the function of the complete machine: 1) Automatic start-up and positioning via a signal, e.g. from a PLC 2) Manual start-up and positioning via a manually-operated potentiometer or joystick.

Page 8: TECH system Type 288-SAFadmin.linak.as/corporate/pdf/english/user manual/thirdparty/tech-system... · TECH-system Type 288-SAF is comprised of a motor control unit and an actuator

Instruction Manual for TECH system type 288-SAF

_______________________________________________________________________________________ Page 8 of 35 jan. 2019 ver. 06

LINAK Danmark A/S - Mønstedsvej 9- DK-8600 Silkeborg -Tel.: +45 86803611 - www.linak.dk

Dimensions The TR-EM-288-SAF motor control unit fitted in a plastic box with integrated power supply Weight: 2.4 kg

Page 9: TECH system Type 288-SAFadmin.linak.as/corporate/pdf/english/user manual/thirdparty/tech-system... · TECH-system Type 288-SAF is comprised of a motor control unit and an actuator

Instruction Manual for TECH system type 288-SAF

_______________________________________________________________________________________ Page 9 of 35 jan. 2019 ver. 06

LINAK Danmark A/S - Mønstedsvej 9- DK-8600 Silkeborg -Tel.: +45 86803611 - www.linak.dk

TR-EM-288-SAF for mounting on DIN rail TR-EM-288-SAF mounted in plastic housing without power supply for integration into an electrical panel. Weight: approx. 200 g Weight: approx. 300 g Motor control unit TR-EM-288-SAF as separate PCB

Page 10: TECH system Type 288-SAFadmin.linak.as/corporate/pdf/english/user manual/thirdparty/tech-system... · TECH-system Type 288-SAF is comprised of a motor control unit and an actuator

Instruction Manual for TECH system type 288-SAF

_______________________________________________________________________________________ Page 10 of 35 jan. 2019 ver. 06

LINAK Danmark A/S - Mønstedsvej 9- DK-8600 Silkeborg -Tel.: +45 86803611 - www.linak.dk

Data plate and labelling Data plate on TR-EM-288-SAF control unit: Data plate on actuator :

Page 11: TECH system Type 288-SAFadmin.linak.as/corporate/pdf/english/user manual/thirdparty/tech-system... · TECH-system Type 288-SAF is comprised of a motor control unit and an actuator

Instruction Manual for TECH system type 288-SAF

_______________________________________________________________________________________ Page 11 of 35 jan. 2019 ver. 06

LINAK Danmark A/S - Mønstedsvej 9- DK-8600 Silkeborg -Tel.: +45 86803611 - www.linak.dk

Declaration of Incorporation

Page 12: TECH system Type 288-SAFadmin.linak.as/corporate/pdf/english/user manual/thirdparty/tech-system... · TECH-system Type 288-SAF is comprised of a motor control unit and an actuator

Instruction Manual for TECH system type 288-SAF

_______________________________________________________________________________________ Page 12 of 35 jan. 2019 ver. 06

LINAK Danmark A/S - Mønstedsvej 9- DK-8600 Silkeborg -Tel.: +45 86803611 - www.linak.dk

Connection and installation Screw terminals are used to connect the TR-EM-288-SAF motor control unit. A general description of the individual terminals is presented below. See the diagrams later in this manual for information about the correct connection of the different actuators.

Fitting the motor control unit Four versions of the TR-EM-288-SAF motor control unit are available:

1. Separate PCB: Order no.: TR-EM-288-SAF 2. PCB fitted in box: Order no.: TR-EM-288-SAF-H 3. PCB mounted on DIN rail for panel mounting: Order no.: TR-EM-288-SAF-R 4. PCB fitted in box with power supply: Order no.: TR-EM-288-SAF-T-230

Separate PCB – TR-EM-288-SAF The PCB is fitted using three 3-mm-diameter screws and connected to an external power supply. The height of the PCB is approx. 25 mm.

Page 13: TECH system Type 288-SAFadmin.linak.as/corporate/pdf/english/user manual/thirdparty/tech-system... · TECH-system Type 288-SAF is comprised of a motor control unit and an actuator

Instruction Manual for TECH system type 288-SAF

_______________________________________________________________________________________ Page 13 of 35 jan. 2019 ver. 06

LINAK Danmark A/S - Mønstedsvej 9- DK-8600 Silkeborg -Tel.: +45 86803611 - www.linak.dk

PCB fitted on DIN rail for panel installation - TR-EM-288-SAF-R The PCB is mounted on a DIN rail and connected to an external power supply.

Page 14: TECH system Type 288-SAFadmin.linak.as/corporate/pdf/english/user manual/thirdparty/tech-system... · TECH-system Type 288-SAF is comprised of a motor control unit and an actuator

Instruction Manual for TECH system type 288-SAF

_______________________________________________________________________________________ Page 14 of 35 jan. 2019 ver. 06

LINAK Danmark A/S - Mønstedsvej 9- DK-8600 Silkeborg -Tel.: +45 86803611 - www.linak.dk

PCB fitted in box with internal power supply – TR-EM-288-SAF-T-230 The box is fitted using four screws and the power supply unit is connected to 230 V AC mains voltage as shown below.

Fuse

Connect 230 V AC mains voltage to the transformer

Page 15: TECH system Type 288-SAFadmin.linak.as/corporate/pdf/english/user manual/thirdparty/tech-system... · TECH-system Type 288-SAF is comprised of a motor control unit and an actuator

Instruction Manual for TECH system type 288-SAF

_______________________________________________________________________________________ Page 15 of 35 jan. 2019 ver. 06

LINAK Danmark A/S - Mønstedsvej 9- DK-8600 Silkeborg -Tel.: +45 86803611 - www.linak.dk

Connection of the motor control unit List of terminals on the motor control unit, TR-EM-288-SAF

Terminal 1: Supply voltage (- gnd) Terminal 2: Voltage to motor on actuator (-24 V DC) Terminal 3: Voltage to motor on actuator (+24 V DC) Terminal 4: Supply voltage (+ 10-35 V DC) smoothed voltage. Terminal 5: Supply to external end stop switch Terminal 6: External end stop switch - OUT Terminal 7: External end stop switch - IN Terminal 8: Signal GND Terminal 9: Signal from actuator Terminal 10: Not in use Terminal 11: Service/reset (terminals 11+14) Terminal 12: Input for control signal (0-5.5 V/0-11 V/4-20 mA Terminal 13: Combined output (current position/error signal) Terminal 14: Supply 5 V/10 mA

Page 16: TECH system Type 288-SAFadmin.linak.as/corporate/pdf/english/user manual/thirdparty/tech-system... · TECH-system Type 288-SAF is comprised of a motor control unit and an actuator

Instruction Manual for TECH system type 288-SAF

_______________________________________________________________________________________ Page 16 of 35 jan. 2019 ver. 06

LINAK Danmark A/S - Mønstedsvej 9- DK-8600 Silkeborg -Tel.: +45 86803611 - www.linak.dk

Installing the actuators When installing actuators, it is important to make sure that the actuators can move freely along their full stroke length, without being limited by the mechanical construction. It is also important to ensure that the machine is not subject to uneven twisting and traction, nor to unevenly distributed load.

NB! The actuator must only be secured using the piston end and rear fastening plate – never the outer tube of the spindle or the motor housing. For additional information, please refer to the data sheet for the actuator in question.

WARNING! Never turn the actuator's spindle for possible adjustment during assembly. This results in immediate errors on positioning, when the actuator is then connected to the control and is started up.

Page 17: TECH system Type 288-SAFadmin.linak.as/corporate/pdf/english/user manual/thirdparty/tech-system... · TECH-system Type 288-SAF is comprised of a motor control unit and an actuator

Instruction Manual for TECH system type 288-SAF

_______________________________________________________________________________________ Page 17 of 35 jan. 2019 ver. 06

LINAK Danmark A/S - Mønstedsvej 9- DK-8600 Silkeborg -Tel.: +45 86803611 - www.linak.dk

Connection of LINAK actuators The majority of LINAK actuators are supplied as standard with a pre-fitted cable, and the actuators are also fitted with different types of plugs depending on which control box has been selected for control operations. For operation with TR-EM-288-SAF, actuators are typically supplied without plugs.

LA12 with potentiometer LA30/32 with potentiometer

Page 18: TECH system Type 288-SAFadmin.linak.as/corporate/pdf/english/user manual/thirdparty/tech-system... · TECH-system Type 288-SAF is comprised of a motor control unit and an actuator

Instruction Manual for TECH system type 288-SAF

_______________________________________________________________________________________ Page 18 of 35 jan. 2019 ver. 06

LINAK Danmark A/S - Mønstedsvej 9- DK-8600 Silkeborg -Tel.: +45 86803611 - www.linak.dk

The new generation of actuators is fitted with minifit plugs in the motor housing, and thus supplied without fitted cables. In contrast to the cable types mentioned above, the supply and signal conductors have now been separated and are thus in individual cables.

Signal cable

Motor cable Order no.: 0367002-1500

LA35 LA36

Signal cable

LA23

Motor cable Order no.: 0237008-0750-A

Page 19: TECH system Type 288-SAFadmin.linak.as/corporate/pdf/english/user manual/thirdparty/tech-system... · TECH-system Type 288-SAF is comprised of a motor control unit and an actuator

Instruction Manual for TECH system type 288-SAF

_______________________________________________________________________________________ Page 19 of 35 jan. 2019 ver. 06

LINAK Danmark A/S - Mønstedsvej 9- DK-8600 Silkeborg -Tel.: +45 86803611 - www.linak.dk

Connection diagram for LINAK actuators The following pages present diagrams for the various types of actuators, together with LINAK's recommended parameter values.

• Actuator LA12 w/potentiometer (11 Kohm): Item no.: 12xPxxxxxx24xx • Actuator LA12 w/Hall potentiometer (0-10 V): Item no.: 12xBxxxxxx24xx • Actuator LA23 w/Hall potentiometer (0-5 V): Item no.: 23xxxxxx14xxxBx • Actuator LA30 w/potentiometer (1 Kohm): Item no.: 30xxPx-xxxxx0xx • Actuator LA32 w/potentiometer (1 Kohm): Item no.: 32xxPx-xxxxx0xx • Actuator LA35 w/Hall potentiometer (0-10 V): Item no.: 35xxxxxxAxxxBxx • Actuator LA36 w/Hall potentiometer (0-10 V): Item no.: 36xxxx+xBxxxB2x

Page 20: TECH system Type 288-SAFadmin.linak.as/corporate/pdf/english/user manual/thirdparty/tech-system... · TECH-system Type 288-SAF is comprised of a motor control unit and an actuator

Instruction Manual for TECH system type 288-SAF

_______________________________________________________________________________________ Page 20 of 35 jan. 2019 ver. 06

LINAK Danmark A/S - Mønstedsvej 9- DK-8600 Silkeborg -Tel.: +45 86803611 - www.linak.dk

LA12 potentiometer Item no.: 12xPxxxxxx24xx

LA12 Hall potentiometer Item no.: 12xBxxxxxx24xx

LA30/32 potentiometer Item no.: 30xxPx-xxxxx0xx Item no.: 32xxPx-xxxxx0xx

Page 21: TECH system Type 288-SAFadmin.linak.as/corporate/pdf/english/user manual/thirdparty/tech-system... · TECH-system Type 288-SAF is comprised of a motor control unit and an actuator

Instruction Manual for TECH system type 288-SAF

_______________________________________________________________________________________ Page 21 of 35 jan. 2019 ver. 06

LINAK Danmark A/S - Mønstedsvej 9- DK-8600 Silkeborg -Tel.: +45 86803611 - www.linak.dk

LA23 Hall potentiometer Item no.: 23xxxxxx14xxxBx

LA35 Hall potentiometer Item no.: 35xxxxxxAxxxBxx

LA36 Hall potentiometer Item no.: 36xxxx+xBxxxB2x

Page 22: TECH system Type 288-SAFadmin.linak.as/corporate/pdf/english/user manual/thirdparty/tech-system... · TECH-system Type 288-SAF is comprised of a motor control unit and an actuator

Instruction Manual for TECH system type 288-SAF

_______________________________________________________________________________________ Page 22 of 35 jan. 2019 ver. 06

LINAK Danmark A/S - Mønstedsvej 9- DK-8600 Silkeborg -Tel.: +45 86803611 - www.linak.dk

Connection diagram for service/reset button

Page 23: TECH system Type 288-SAFadmin.linak.as/corporate/pdf/english/user manual/thirdparty/tech-system... · TECH-system Type 288-SAF is comprised of a motor control unit and an actuator

Instruction Manual for TECH system type 288-SAF

_______________________________________________________________________________________ Page 23 of 35 jan. 2019 ver. 06

LINAK Danmark A/S - Mønstedsvej 9- DK-8600 Silkeborg -Tel.: +45 86803611 - www.linak.dk

Parameter settings The TR-EM-288-SAF motor control unit has 24 parameters that can be set to match the individual machine. To change these parameters, portable serial interface handset TR-EM-236 must be connected to the motor control unit. NB! To use the TR-EM-236 portable serial interface handset, the control unit must first be connected to a power supply.

Portable serial interface handset TR-EM-236 Press ARROW DOWN for 2 seconds to call up the main menu on the handset. In the main menu, use ARROW UP or ARROW DOWN to select the menu item required. To open the menu in question, click the + (plus) button. To alter the parameter values, select the "Load & Edit" menu item Use the arrow keys to select the parameter you wish to alter. The parameter selected is shown in the display as <1 / 11>, which means parameter 1 of 11. The value is presented in square brackets [ ] and can be changed by pressing the plus or minus buttons Once you have made the changes you require, save the new configuration by pressing ARROW UP for at least 2 seconds.

Value Parameter in question. In this case, 1 of 11.

Page 24: TECH system Type 288-SAFadmin.linak.as/corporate/pdf/english/user manual/thirdparty/tech-system... · TECH-system Type 288-SAF is comprised of a motor control unit and an actuator

Instruction Manual for TECH system type 288-SAF

_______________________________________________________________________________________ Page 24 of 35 jan. 2019 ver. 06

LINAK Danmark A/S - Mønstedsvej 9- DK-8600 Silkeborg -Tel.: +45 86803611 - www.linak.dk

Parameters The following parameters can be adjusted as required or desired:

1. Not in use: No function. 2. Switch control status: Selection of control type for external end stop switches 3. Speed, Forward Setting the speed, Forward 4. Speed, Backward Setting the speed, Backward 5. Speed, Service: Setting the speed, Service run 6. Current limit, OUT: Setting current limit, OUT 7. Current limit, IN: Setting current limit, IN 8. Current trip delay: Setting time in milliseconds 9. Read fault values: Setting fault type for reading (terminal 13) 10. Voltage overload limit: Setting voltage overload limit (15-40 V) 11. Load compensation: Setting load compensation 12. Operating time: Setting max. operating time in seconds 13. Manual reset: Reset timer 14. Service/Reset setting: Setting service/reset function 15. Start conditions: Setting start function after fault 16. Not in use: 17. Dead band: Setting dead band interval 18. Braking accuracy: Setting actuator braking 19. Start ramp: Setting start ramp (0.2.5 s) 20. Stop ramp: Setting stop ramp (0-2.5 s) 21. Set value, control signal - MIN.: Setting minimum control voltage from 0-5.5 V 22. Set value, control signal - MAX.: Setting maximum control voltage from 0-5.5 V 23. Max. stroke length OUT: Setting stroke length limit, OUT 24. Max. stroke length IN: Setting stroke length limit, IN 25. Motor frequency: Setting Motor frequency to 2 or 16 kHz

NB! The parameter values recommended by LINAK are also available in the connection diagrams for the individual actuators.

Page 25: TECH system Type 288-SAFadmin.linak.as/corporate/pdf/english/user manual/thirdparty/tech-system... · TECH-system Type 288-SAF is comprised of a motor control unit and an actuator

Instruction Manual for TECH system type 288-SAF

_______________________________________________________________________________________ Page 25 of 35 jan. 2019 ver. 06

LINAK Danmark A/S - Mønstedsvej 9- DK-8600 Silkeborg -Tel.: +45 86803611 - www.linak.dk

Parameter settings (basic setting)

Parameter Description LA12P/B LA23 LA30/32 LA35 LA36

1 No function 0 0 0 0 0 2 Limit input logic 1 1 1 1 1 3 Speed forward 100 100 100 100 100 4 Speed backward 100 100 100 100 100 5 Speed service-driving 60 60 60 60 60 6 Current Cut off forward 20 15 50 50 130 7 Current Cut off backward 20 15 50 50 130 8 Current Cut off delay 50 50 50 50 50 9 Error read out (klemme/terminal 13) 1 1 1 1 1

10 Over voltage limit 35 35 35 35 35 11 Load compensation 0 0 0 0 0 12 Time out cut off 0 0 0 0 0 13 Reset hour counter ( 1 = reset) 0 0 0 0 0 14 Service run (>5 sec. Klemme/therminal 11) 1 1 1 1 1 15 Reset 1 1 1 1 1 16 No function 0 0 0 0 0 17 Dead band 15 15 15 15 15 18 Bracking area 4 1 1 1 1 19 Start ramp 5 5 5 5 5 20 Stop ramp 3 3 3 3 3 21 Min. Set value 0 0 0 0 0 22 Max. Set value 550 550 550 550 550 23 Max. Stroke IN 0 0 0 0 0 24 Max. Stroke OUT 0 0 0 0 0 25 Motor frequency (1=2khz; 2=16khz) 1 1 1 1 1

Page 26: TECH system Type 288-SAFadmin.linak.as/corporate/pdf/english/user manual/thirdparty/tech-system... · TECH-system Type 288-SAF is comprised of a motor control unit and an actuator

Instruction Manual for TECH system type 288-SAF

_______________________________________________________________________________________ Page 26 of 35 jan. 2019 ver. 06

LINAK Danmark A/S - Mønstedsvej 9- DK-8600 Silkeborg -Tel.: +45 86803611 - www.linak.dk

Explanation of parameters The following section presents a more detailed explanation of the individual parameters. To set the parameters, enter a number in the display. NB! LINAK´s recommended parameters are presented in { } after each description below. No function: This parameter is not in use. The value "0" must be stated.

{0}

Switch control status: This parameter states which control status or external end stop switches

the connected terminals 7 and 8 are activated with. PNP or NPN The following options are available:

1 = PNP 2 = NPN 3 = PNP inverted 4 = NPN inverted

{1} LINAK sensors use type PNP. Speed OUT: This parameter makes it possible to set the actuator operating speed in

the outward direction. The speed is stated in %. Max. speed = 100%. The following options are possible:

20 – 100 {100} Speed IN: This parameter makes it possible to set the actuator operating speed in

the inward direction. The speed is stated in %. Max. speed = 100%. The following options are possible:

20 – 100 {100}

Speed (service): This parameter makes it possible to set the actuator operating speed

while it is running in service mode. The speed is stated in %. Max. speed = 100%. The following options are possible:

20 – 100 {60} Current limit, OUT: This parameter is used to state the max. permitted current consumption

for each actuator connected when moving OUT. The current limit is measured in Amp. From 0.1-20 A. The following options are available: 1 to 200 {30} (depending on actuator type)

1

3

4

2

6

5

Page 27: TECH system Type 288-SAFadmin.linak.as/corporate/pdf/english/user manual/thirdparty/tech-system... · TECH-system Type 288-SAF is comprised of a motor control unit and an actuator

Instruction Manual for TECH system type 288-SAF

_______________________________________________________________________________________ Page 27 of 35 jan. 2019 ver. 06

LINAK Danmark A/S - Mønstedsvej 9- DK-8600 Silkeborg -Tel.: +45 86803611 - www.linak.dk

Current limit, IN: This parameter is used to state the max. permitted current consumption

for each actuator connected when moving IN. The current limit is measured in Amp. From 0.1-20 A. The following options are available: 1 to 200 {30} (depending on actuator type)

Delay: This parameter is used to state the time lapse in milliseconds before the

control switches off at the current limit. The delay is measured in milliseconds from 0-255 ms.

The following options are available: 0 to 255, (0=deactivated) {20}

Reading fault values: (Combi-port) This parameter is used to set when a signal is sent to terminal 13. The following options are available:

1 = in the event of any fault 2 = when the actuator's position is correct 3 = reading off the current position (0-5 V) 4 = current position (0.5-4.5 V) and in the event of fault signal = 0 V

{1}

Voltage overload limit: This parameter makes it possible to set a value for at which voltage the

voltage overload protection should disconnect the control. A voltage between 15-40 V may be selected.

The following options are available:

15-40 {35}

Load compensation: This parameter is used to optimise low speed and start torque. If compensation is too high, actuator operation will be unstable. Run the motor at low speed (30%) and increase compensation very gradually until the motor control unit begins to operate in an unstable way. Then reduce the value by approx. 10%. The following options are available:

0-255 {0}

7

10

9

11

8

Page 28: TECH system Type 288-SAFadmin.linak.as/corporate/pdf/english/user manual/thirdparty/tech-system... · TECH-system Type 288-SAF is comprised of a motor control unit and an actuator

Instruction Manual for TECH system type 288-SAF

_______________________________________________________________________________________ Page 28 of 35 jan. 2019 ver. 06

LINAK Danmark A/S - Mønstedsvej 9- DK-8600 Silkeborg -Tel.: +45 86803611 - www.linak.dk

Operating time: This parameter can be used to set the maximum permitted operating

time for the actuator measured in seconds. The following options are available:

0-255 (0 = deactivated) {0}

Reset: (Start and hour counter) This parameter resets the start and hour counter. Reset the counter as

follows: Set this parameter to 1 and press Save. Then set the parameter again to

0. The following options are available:

0 - 1 {0}

Service operation: This parameter states the direction in which the actuator must run when

the "Service run" function is activated via a button connected between terminals 11 and 14. The button must be activated for more than 5 seconds to be in force.

The following options are available: 0 = actuator runs IN 1 = actuator runs OUT {0}

Resetting the error signal: This parameter is used to define how an error is reset. The button must

be activated for more than 5 seconds to be in force. The following options are available:

0 = reset on activation of the button between terminals 11 and 14 1 = reset on running in the opposite direction {0} Not in use: This parameter is not in use {0} Dead band: This parameter is used to define the width of the "dead" zone in which

the control unit considers the actuators to have reached the position required. The width can be set in the range of 0.2-5% The following options are available:

2 to 50 {10}

15

16

17

12

13

14

Page 29: TECH system Type 288-SAFadmin.linak.as/corporate/pdf/english/user manual/thirdparty/tech-system... · TECH-system Type 288-SAF is comprised of a motor control unit and an actuator

Instruction Manual for TECH system type 288-SAF

_______________________________________________________________________________________ Page 29 of 35 jan. 2019 ver. 06

LINAK Danmark A/S - Mønstedsvej 9- DK-8600 Silkeborg -Tel.: +45 86803611 - www.linak.dk

Braking accuracy: This parameter states when the actuator must begin to brake, before

reaching its position. The accuracy can be set in the range of 1-8%

The following options are available: 1 to 8 {3} Start ramp: This parameter makes it possible to set the start ramp up to a soft start.

The start ramp time is measured in seconds from 0.1-2.5 s. The following options are available:

1 to 25 {5} Stop ramp: This parameter makes it possible to set the stop ramp down to a soft

stop. The stop ramp time is measured in seconds from 0.1-2.5 s. The following options are available:

1 to 25 {3} Set value, MIN.: (Control signal) This parameter can be used to state a minimum value for the control

signal from 0-5.5 V. If the value 551 is stated, the value is found automatically by the

control. The following options are available:

0 to 551

{0} To use the control signal with the value measured in milliamperes from

4-20 mA, a resistance of 249 Ohm must be mounted in terminal X8 (see diagram page 16)

Parameter 21 is set at 100 = 4 mA Set value, MAX.: (Control signal) This parameter can be used to state a maximum value for the control

signal from 0-5.5 V. If the value 551 is stated, the value is found automatically by the

control. The following options are available:

0 to 551 {551} To use the control signal with the value measured in milliamperes from

4-20 mA, a resistance of 249 Ohm must be mounted in terminal X8 (see diagram page 16)

Parameter 22 is set at 500 = 20 mA

21

18

20

19

22

Page 30: TECH system Type 288-SAFadmin.linak.as/corporate/pdf/english/user manual/thirdparty/tech-system... · TECH-system Type 288-SAF is comprised of a motor control unit and an actuator

Instruction Manual for TECH system type 288-SAF

_______________________________________________________________________________________ Page 30 of 35 jan. 2019 ver. 06

LINAK Danmark A/S - Mønstedsvej 9- DK-8600 Silkeborg -Tel.: +45 86803611 - www.linak.dk

Stroke length, OUT: This parameter is used to define the required limitation of the stroke

length from 0-50% of the total stroke length OUT. NB! The "Service" function overrides this parameter. The following options are available:

0 to 500

{0} Stroke length, IN: This parameter is used to define the required limitation of the stroke

length from 0-50% of the total stroke length IN. NB! The "Service" function overrides this parameter. The following options are available: 0 to 500

{0} Motor frequency: This parameter is used to define the motor frequency in kHz 1 = 2 kHz ; 2 = 16 kHz

The following options are available: 1 or 2

{1}

23

24

25

Page 31: TECH system Type 288-SAFadmin.linak.as/corporate/pdf/english/user manual/thirdparty/tech-system... · TECH-system Type 288-SAF is comprised of a motor control unit and an actuator

Instruction Manual for TECH system type 288-SAF

_______________________________________________________________________________________ Page 31 of 35 jan. 2019 ver. 06

LINAK Danmark A/S - Mønstedsvej 9- DK-8600 Silkeborg -Tel.: +45 86803611 - www.linak.dk

Start/operation Before starting to use the system, it is important that all parameters in the motor control unit have been set correctly according to the specifications for the actuator in question. (see page 24)

Appropriate use:

• The system is only intended/designed for use as a component part in machinery or equipment used in an industrial environment.

• After fitting, test the system to check that it functions correctly. • The machine must be allowed free movement along the full stroke length of the actuator. • Bolts attached to the actuator's piston rod and rear fastening plate must be secure. • Ensure that the system is connected to the correct voltage.

Inappropriate use:

• Duty cycle must not exceed 10%: max. 2 minutes' operation followed by an 18-minute pause. • The actuator must not bear a load in excess of the max. load stated on the data plate. • The actuator must not bear a transverse load. • The actuator must not be subjected to knocks and violent jolts. • Unevenly distributed loads will exert oblique stress on the actuators. • The system must not be connected to a different voltage than the voltage stated on the data

plate. • The control box and power supply must not be covered. • The equipment is not suitable for use in the vicinity of flammable, anaesthetic mixtures of air,

oxygen or nitrous oxide (laughing gas). • The system is not suitable for machines which can be described as: • Medical devices • Equipment for use in the offshore industry (ATEX) • Aircraft • Nuclear power plant • The system must not be used until it is incorporated safely into the end product.

Maintenance

• Clean the surface of the systems at appropriate intervals to remove dust and dirt, and check for signs of damage and breakage.

• Check all connections, cables, housing and connectors, and check that the system functions correctly.

• With the exception of motor control units with PCB or those prepared for mounting in an electrical panel, the control boxes are sealed and maintenance-free.

• Check all connections, cables, housing and connectors. • For actuators with sealing class IPX6 rating and better: if cleaned using water, these units

should only be washed when the piston rod (spindle) is fully extended.

Page 32: TECH system Type 288-SAFadmin.linak.as/corporate/pdf/english/user manual/thirdparty/tech-system... · TECH-system Type 288-SAF is comprised of a motor control unit and an actuator

Instruction Manual for TECH system type 288-SAF

_______________________________________________________________________________________ Page 32 of 35 jan. 2019 ver. 06

LINAK Danmark A/S - Mønstedsvej 9- DK-8600 Silkeborg -Tel.: +45 86803611 - www.linak.dk

Reading monitoring values Using a TR-EM-236 portable serial interface handset, it is possible to read the current values for the system. Five values can be displayed. In the main menu, use ARROW DOWN to select the "Monitor Values" menu.

Explanation of monitoring values 1. Fault codes: (see below) 2. Motor current: 0 – 20 A = (0 - 200) 3. Target position: 0 – 100 % = (0 - 1000) 4. Realized position: 0 – 100 % = (0 - 1000) 5. Hour counter: Displays no. of operating hours (max. 65,535 hours) 4. Start counter: Displays no. of starts (max. 65,535) 5. Start counters over flow counter: Secondary counter for start counter Fault codes:

1. Power limit is reached 2. Time out 3. Disconnected due to overheating 4. Voltage overload

Service operation Service run is a function that makes it possible to "force" the actuator to run to one of its end positions, beyond any stroke length limit. The function is achieved by mounting a button between terminals 11 and 14 (see diagram page 23). The button must be activated for more than 5 seconds for the function to be in force. The required function is selected at parameter 14: 0 = Actuator runs IN on pressing the button 1 = Actuator runs OUT on pressing the button NB! The actuator only runs for as long as the button is pressed in. When the button is released, the actuator returns to the last position set.

Page 33: TECH system Type 288-SAFadmin.linak.as/corporate/pdf/english/user manual/thirdparty/tech-system... · TECH-system Type 288-SAF is comprised of a motor control unit and an actuator

Instruction Manual for TECH system type 288-SAF

_______________________________________________________________________________________ Page 33 of 35 jan. 2019 ver. 06

LINAK Danmark A/S - Mønstedsvej 9- DK-8600 Silkeborg -Tel.: +45 86803611 - www.linak.dk

Troubleshooting If an error occurs, the actuators will stop operating and the error condition will be indicated by a red LED on the PCB. The LEDs are visible when the cover of the control unit is removed.

Reading errors In the event of an error, the red LED will flash. The flashes mean the following:

1. power limit is reached: 1 flash 2. time out: 2 flashes 3. disconnected due to overheating: 3 flashes 4. voltage overload: 4 flashes

To reset errors Errors can be reset in 2 ways, either by activating a reset button mounted between terminals 11 and 14, or by running the actuator in the opposite direction. (See the diagram on page 23) The reset button must be activated for more than 5 seconds for the function to be in force. The required function is selected at parameter 15: 0 = reset by pressing the button 1 = reset by running the actuator in the opposite direction

Red LED = Error condition

Page 34: TECH system Type 288-SAFadmin.linak.as/corporate/pdf/english/user manual/thirdparty/tech-system... · TECH-system Type 288-SAF is comprised of a motor control unit and an actuator

Instruction Manual for TECH system type 288-SAF

_______________________________________________________________________________________ Page 34 of 35 jan. 2019 ver. 06

LINAK Danmark A/S - Mønstedsvej 9- DK-8600 Silkeborg -Tel.: +45 86803611 - www.linak.dk

Key to symbols NB! None of the products carries all of the symbols described here.

Page 35: TECH system Type 288-SAFadmin.linak.as/corporate/pdf/english/user manual/thirdparty/tech-system... · TECH-system Type 288-SAF is comprised of a motor control unit and an actuator

Instruction Manual for TECH system type 288-SAF

_______________________________________________________________________________________ Page 35 of 35 jan. 2019 ver. 06

LINAK Danmark A/S - Mønstedsvej 9- DK-8600 Silkeborg -Tel.: +45 86803611 - www.linak.dk

Disposal of LINAK products To dispose of LINAK products, start by sorting them into different categories for recycling or incineration. We recommend that you dismantle your product as fully as possible for disposal, and that you reuse the parts. Sorting categories may include:

• metal • plastic • cables • flammable material • reuse

It is possible to subdivide within some of these categories. For example, “metal” can be subdivided into steel and aluminium, while “plastic” can be divided into ABS and PP. As an example of sorting, the table below illustrates the various categories under which the LINAK components are to be sorted.