FULL FEATURED AND AFFORDABLE
EASY-TO-OPERATE
Vibration pen with:
Overall vibration measurement and Built-in FFT
Bearing condition monitoring based on high frequency enveloping
Store up to 500 points (LF waveforms or envelope waveforms)
Route and off-route data acquisition
PC connection via USB for detailed analysis
EASY AND QUICK OPERATION
Pocket size and light weight, built-in sensor and a handy design
make this data collector always within reach, ready to measure
vibration and control machine condition. Contrast graphic display
with backlight and built-in FFT are designed for easy on-site
condition monitoring and data analysis.
Auto shutdown feature significantly increases battery lifetime.
STD-500 Vibration Data Collector
TECHNEKON | 2
TECHNEKON | 3
MULTIFUNCTIONAL
From quick on-site analysis to the delailed data processing
on your PC including spectrum analysis, trends creation,
detection location and severity of faults: imbalance,
misalignment, bed belt, bearing failure, soft foundation
and maintaining machinary condition database.
ROUTE AND OFF-ROUTE USABILITY
Uploading routes from Vibrodesigner Analysis Software
facilitates both data acquisition and creating of a unified
repository of diagnostics data by further automatic
downloading data onto your computer.
TECHNEKON | 4
EASY TO USE
Only two buttons and intuitive menu make operation simple and
convenient:
point and press ENTER button
message is displayed on the LCD. The measured value is
shown, and collected wave is saved in the memory.
keyboard
display
tip
USB port
Power connector
EXTRA FEATURES
measurement
Free firmware update available via USB
MEASUREMENT
Sensor built-in piezoelectric accelerometer
Low frequency measurement 10 to 1000 Hz (±1dB)
Enveloping measurement 5 kHz to 15 kHz
Sampling 8192
Internal FFT 3200 lines
MEMORY
DISPLAY
Type graphic, monochrome, with backlight
PC CONNECTION USB
POWER SUPPLY
Operating during up to 10 hours
Charging during up to 4 hours
ENVIRONMENT
Intrinsically save 1ExibIIBT3X
Case protection IP54
Tempreture -20 … +50 С
Humidity 90%
SIZE
WEIGHT 0,150 kg. (5,3 oz)
TECHNEKON | 5
Vibration Data Collector STD-500FEATURED AND AFFORDABLE EASY-TO-OPERATE
Vibration Data Collector STD-500
STD-500 Accessories
Accessories:
•TD-500 Data Collector•USB cable•Charger•Case•Package
STD-500 Interface
Vibration pen with:
•• Overall vibration measurement and Built-in FFT• Bearing condition monitoring based on high frequency enveloping• Store up to 500 points (LF waveforms or envelope waveforms)• Route and off-route data acquisition• PC connection via USB for detailed analysis
Physical and ElectricalSpecifications
Frequency range, Hz 10–1000
Enveloping measurement 5 kHz to 15 kHz
Vibration velocity RMS limits, mm/s 0.5-70
Measurement units Acceleration, Velocity, Displacement (P-P, Peak, RMS)
Sampling 8192Bandpass flatness, dB less than 1
Operating temperature, ° -20…+50Operating humidity (+35° ) 90%
Case dimensions, mm 186 35 21Weight, grams less than 150
Continuous use after complete charging, hours up to 10
Quick Start
1. Press the right button ( ) on the STD-500 front panel.The data collector is switched on. The main menu is displayed on the left of the LCD screen.2. To perform measurements, use the right button ( ) to navigate to theMEAS. iitem.3. Press the left button.The Measurement menu is displayed. The machine single-line menu is highlighted.4. Use the right button to select the machine you need.5. When selected, press the left button.The measurement point single-line menu is highlighted.
Quick Start
6. Use the right button to select the point you need.7. To start data acquisition, attach your data collector perpendicularly to the needed pointand press the left button.When finished, the Measurement is completed message is displayed on the LCD. The new data is recorded instead of old data.8. Press both buttons simultaneously.You are returned to the main menu.9. To analyze the collected data, use the right button to navigate to the ANALYS itemand then press the left button.10. Press the left button twice and view the collected data.
Main menu
Data Collection Mode
Data collection is performed from the main program menu.
Main menu
Data collection is carried out through the predefined route or in off-route points. Routes are uploaded into the STD-500 by means of Vibrodesigner-Expert and contain machines and machine points.A machine menu displays machine names of the uploaded routes. For off-route points, you can see “OFF-ROUTE” in the machine menus.A machine point menu displays the points in the following format: <NNN XXY NAME>, where NNN – the number of a point in the route, XX – the point number on a machine. Y – a measurement direction, NAME – a point name. Off-route points are displayed as <Point name NNN>, where NNN is the number of an off-route point.A machine is selected in the single-line machine menu. Pressing the left button results in switching to the machine point selection.
Data Collection Mode
Pressing the left button in the selected point results in either low-frequency measurement, or high-frequency envelope measurement, or in switching to the Analysis mode. To change the mode, press both the left and right buttons simultaneously to go back to the machinemenu, and then press both buttons again to go back to the main menu.In the main menu, you can select the following actions:· MEAS. – switch to the low-frequency signal measurement· MEAS. E – switch to the high-frequency measurement of the signal envelope· ANALYS – switch to the Analysis mode of the selected point.Depending on what parameters were used during the route point uploading, whether the low-frequency or high-frequency measurement is performed. So, you will see eitherMEAS or MEAS E in the lower left corner of the screen.
Main menu
Watch mode
In the Watch mode, the STD-500 collects vibration data and calculates an integral parameter without saving results in the device memory. To switch to the Watch mode, go to the main menu and select the Watch item.The Watch menu includes the following items:· MEAS – switch to the low-frequency signal measurement· MEAS E – switch to the high-frequency measurement of the signal envelope· ANALYS – switch to the Analysis mode of the measure.· UNITS – switch to the single-line menu to select measurement units for the low frequency measures. You cannot change measurement units for high-frequencysignals.
Main menu
Analysis ModeThe Analysis mode is designed to enable you to assess the measured data numerically and qualitatively. You can switch to the Analysis mode either from the main menu or from the Watch mode by selecting the ANALYS item.The screen in the Analysis mode is shown in the picture below.
You need first to specify a button mode, that is, which actions will be performed on pressing the buttons in the Analysis mode. You can choose one of the options listed below.
Button mode Description
<> Move the cursor along the X axis
Scl. Enlarge/shrink the X-axis view range
Scl.Y Enlarge/shrink the Y-axis view range
Units Change the graph measurement unit
Main menu
Options Menu
The Options menu commands are used to perform system operations, such as changing internal time and resetting ROM. The Options menu screens are shown in the picture below.
Main menu
Command DescriptionBacklight on Switching on/off highlighting
Set date and time Change internal date and time
Delete route Remove a route from the data collector memory
Del. Off-rt. Points Remove all off-route points from the data collector memory
Erase memory Reset a data collector ROM. This command is availableonly if the Memory error occurred
Accel <parameter> <meas units> Settings of the acceleration parameterVelocity <parameter> <meas units> Settings of the velocity parameter
Displ. <parameter> <meas units> Settings of the displacement parameter
Frequency <meas units> Settings of measurement unit for the frequency to be displayed
Options Menu
Main menu
HF Spectrum Measurement Mode
To switch to the HF spectrum measurement mode, select HF SP. in the device main menu.First, the following message is displayed: “Measure HF spectrum? Yes/No”. Whenconfirmed, acceleration spectrum is measured in the 250-15000 Hz range, and the device is automatically switched to the Analysis mode.
Main menu
Communication with ComputerUse a standard USB cable to connect a STD-500 data collector to your workstation. When connected, the following message appears on the LCD screen: Connected to PC.When working with your data collector, you can use additional Vibrodesignersoftware.
Main menu
Communication with ComputerCreate inspection routes and load them into the data collector
Main menu
Communication with ComputerLoad collected data to a software database
Main menu
Communication with ComputerProcess and analyze collected data
Trends
Main menu
Setting
Communication with ComputerProcess and analyze collected data
Signals
Main menu
Communication with ComputerProcess and analyze collected data
Signals
Main menu First slide