8
Doc #: Rev: 1 Date: 5/4/2020 DESIGN / CONSTRUCTION Body 304L SS External Hardware 304L SS Gaskets Buna-N Motor Body Cast Iron Shaft Seal Single Mechanical Seal Impeller 250 or 305mm Vortex Impeller Standard Maximum Solid Size ø 4" (100 mm) MOTOR SPECIFICATIONS Motor Design 4-Pole, 3-Phase Squirrel-Cage Motor 50Hz/60Hz Motor Type TEFC, IP67 Insulation Class Class F Motor Protection Protected by VFD Service Factor 1.15 Maximum Ambient Temp. 104˚F (40˚C) Voltage Tolerance ±10% Rated Power 230V FLA 460V FLA 575V FLA Weight * Inlet 8" ANSI 150# 18.5kW / 24.8HP -- 35 28 1709lb (777kg) Outlet 6" ANSI 150# 22kW / 29.5HP -- 40.5 32.4 1802lb (819kg) H1 18" (457mm) 30kW / 40.2HP -- 53.4 42.7 1868lb (849kg) H2 17.1" (434mm) 37kW / 49.6HP -- 66.6 53.3 2141lb (973kg) L 40.6" (1031mm) 45kW / 60.3HP -- 80.5 64.4 2493lb (1133kg) P 37" (943mm) 55kW / 73.7HP -- 98 78.4 2889lb (1313kg) * Total weight of unit MOTOR DATA DIMENSIONS (largest motor) TECHNICAL DATA OW101H/4VV DS-A50-047 Industrial Flow Solutions Specifications subject to change without notice Do not use for construction purposes www.flowsolutions.com

TECHNICAL DATA OW101H/4VV

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: TECHNICAL DATA OW101H/4VV

Doc #: Rev: 1 Date: 5/4/2020

DESIGN / CONSTRUCTION

Body 304L SS

External Hardware 304L SS

Gaskets Buna-N

Motor Body Cast Iron

Shaft Seal Single Mechanical Seal

Impeller 250 or 305mm Vortex Impeller Standard

Maximum Solid Size ø 4" (100 mm)

MOTOR SPECIFICATIONS

Motor Design 4-Pole, 3-Phase Squirrel-Cage Motor 50Hz/60Hz

Motor Type TEFC, IP67

Insulation Class Class F

Motor Protection Protected by VFD

Service Factor 1.15

Maximum Ambient Temp. 104˚F (40˚C)

Voltage Tolerance ±10%

Rated Power 230V FLA 460V FLA 575V FLA Weight * Inlet 8" ANSI 150#

18.5kW / 24.8HP -- 35 28 1709lb (777kg) Outlet 6" ANSI 150#22kW / 29.5HP -- 40.5 32.4 1802lb (819kg) H1 18" (457mm)

30kW / 40.2HP -- 53.4 42.7 1868lb (849kg) H2 17.1" (434mm)

37kW / 49.6HP -- 66.6 53.3 2141lb (973kg) L 40.6" (1031mm)

45kW / 60.3HP -- 80.5 64.4 2493lb (1133kg) P 37" (943mm)

55kW / 73.7HP -- 98 78.4 2889lb (1313kg) * Total weight of unit

MOTOR DATA DIMENSIONS (largest motor)

TECHNICAL DATA OW101H/4VV

DS-A50-047

Industrial Flow Solutions Specifications subject to change without notice

Do not use for construction purposes www.flowsolutions.com

Page 2: TECHNICAL DATA OW101H/4VV

Rev 2 ITIC

18.5kW / 24.8HP Poles 4 Date

305x50x30mm

PERFORMANCE CURVE OW101H‐4VV VX 18.5kW

Model

Impeller

DS‐A50‐024

5/13/2021

OW101H 18.5kW

PERFORMANCE CURVE OW101H‐4VV VX 18.5kW

MotorTested with clean water

Test Standard : HI 11.6 Gr 3BSpecifications subject to change without notice

0 20 40 60 80 100 120 140 160 180

0

10

20

30

40

0

20

40

60

80

100

120

140

0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800

m³/h

m feet

US GPM

Total D

ynam

ic Head

0 20 40 60 80 100 120 140 160 180

0.0

5.0

10.0

15.0

20.0

0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800

m³/h

US GPM

Input P1 (kW

)

45 Hz40 Hz

35 Hz

0 20 40 60 80 100 120 140 160 180

0

10

20

30

40

0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800

m³/h

Flow

US GPM

Wire to water eff. (%

)

45 Hz

40 Hz

35 Hz

30 Hz

30 Hz

Page 3: TECHNICAL DATA OW101H/4VV

Rev 2 ITIC

22kW / 29.5HP Poles 4 Date

305x50x30mm

PERFORMANCE CURVE OW101H‐4VV VX 22kW

Model

Impeller

DS‐A50‐025

5/13/2021

OW101H 22kW

PERFORMANCE CURVE OW101H‐4VV VX 22kW

MotorTested with clean water

Test Standard : HI 11.6 Gr 3BSpecifications subject to change without notice

0 20 40 60 80 100 120 140 160 180 200 220

0

10

20

30

40

0

20

40

60

80

100

120

140

160

0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000

m³/h

m feet

US GPM

Total D

ynam

ic Head

0 20 40 60 80 100 120 140 160 180 200 220

0.0

5.0

10.0

15.0

20.0

25.0

0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000

m³/h

US GPM

Input P1 (kW

)

45 Hz

40 Hz

50 Hz

35 Hz

0 20 40 60 80 100 120 140 160 180 200 220

0

10

20

30

40

50

0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000

m³/h

Flow

US GPM

Wire to water eff. (%

)

45 Hz

40 Hz

50 Hz

35 Hz

30 Hz

30 Hz

Page 4: TECHNICAL DATA OW101H/4VV

Rev 2 ITIC

30kW / 40.2HP Poles 4 Date

305x50x30mm

PERFORMANCE CURVE OW101H‐4VV VX 30kW

Model

Impeller

DS‐A50‐026

5/13/2021

OW101H 30kW

PERFORMANCE CURVE OW101H‐4VV VX 30kW

MotorTested with clean water

Test Standard : HI 11.6 Gr 3BSpecifications subject to change without notice

0 20 40 60 80 100 120 140 160 180 200 220

0

10

20

30

40

50

60

0

20

40

60

80

100

120

140

160

180

200

0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000

m³/h

m feet

US GPM

Total D

ynam

ic Head

0 20 40 60 80 100 120 140 160 180 200 220

0.0

5.0

10.0

15.0

20.0

25.0

30.0

35.0

0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000

m³/h

US GPM

Input P1 (kW

)

45 Hz

40 Hz

50 Hz

35 Hz

0 20 40 60 80 100 120 140 160 180 200 220

0

10

20

30

40

50

0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000

m³/h

Flow

US GPM

Wire to water eff. (%

)

45 Hz

40 Hz

50 Hz

35 Hz30 Hz

30 Hz

60 Hz

55 Hz

55 Hz60 Hz

Page 5: TECHNICAL DATA OW101H/4VV

Rev 2 ITIC

37kW / 49.6HP Poles 4 Date

305x50x30mm

PERFORMANCE CURVE OW101H‐4VV VX 37kW

Model

Impeller

DS‐A50‐027

5/13/2021

OW101H 37kW

PERFORMANCE CURVE OW101H‐4VV VX 37kW

MotorTested with clean water

Test Standard : HI 11.6 Gr 3BSpecifications subject to change without notice

0 20 40 60 80 100 120 140 160 180 200 220

0

10

20

30

40

50

60

70

0

20

40

60

80

100

120

140

160

180

200

220

240

0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000

m³/h

m feet

US GPM

Total D

ynam

ic Head

0 20 40 60 80 100 120 140 160 180 200 220

0.0

5.0

10.0

15.0

20.0

25.0

30.0

35.0

40.0

45.0

0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000

m³/h

US GPM

Input P1 (kW

) 45 Hz

40 Hz

50 Hz

35 Hz

0 20 40 60 80 100 120 140 160 180 200 220

0

10

20

30

40

50

0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000

m³/h

Flow

US GPM

Wire to water eff. (%

)

45 Hz40 Hz

50 Hz

35 Hz30 Hz

30 Hz

60 Hz

55 Hz

55 Hz60 Hz

Page 6: TECHNICAL DATA OW101H/4VV

Rev 2 IT

45kW / 60.3HP Poles 4 Date

305x50x30mm

PERFORMANCE CURVE OW101H‐4VV VX 45kW

Model

Impeller

DS‐A50‐028

5/13/2021

OW101H 45kW

PERFORMANCE CURVE OW101H‐4VV VX 45kW

MotorTested with clean water

Test Standard : HI 11.6 Gr 3BSpecifications subject to change without notice

0 20 40 60 80 100 120 140 160 180 200 220

0

10

20

30

40

50

60

70

0

20

40

60

80

100

120

140

160

180

200

220

240

260

0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000

m³/h

m feet

US GPM

Total D

ynam

ic Head

0 20 40 60 80 100 120 140 160 180 200 220

0.0

5.0

10.0

15.0

20.0

25.0

30.0

35.0

40.0

45.0

0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000

m³/h

US GPM

Input P1 (kW

) 45 Hz

40 Hz

50 Hz

35 Hz

0 20 40 60 80 100 120 140 160 180 200 220

0

10

20

30

40

50

0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000

m³/h

Flow

US GPM

Wire to water eff. (%

)

45 Hz40 Hz

50 Hz

35 Hz30 Hz

30 Hz

65 Hz

60 Hz

55 Hz

55 Hz60 Hz65 Hz

Page 7: TECHNICAL DATA OW101H/4VV

Rev 2 ITIC

55kW / 73.7HP Poles 4 Date

305x50x30mm

PERFORMANCE CURVE OW101H‐4VV VX 55kW

Model

Impeller

DS‐A50‐079

5/13/2021

OW101H 55kW

PERFORMANCE CURVE OW101H‐4VV VX 55kW

MotorTested with clean water

Test Standard : HI 11.6 Gr 3BSpecifications subject to change without notice

0 20 40 60 80 100 120 140 160 180 200 220

0

10

20

30

40

50

60

70

0

20

40

60

80

100

120

140

160

180

200

220

240

260

0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000

m³/h

m feet

US GPM

Total D

ynam

ic Head

0 20 40 60 80 100 120 140 160 180 200 220

0.0

5.0

10.0

15.0

20.0

25.0

30.0

35.0

40.0

45.0

50.0

55.0

0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000

m³/h

US GPM

Input P1 (kW

)

45 Hz

40 Hz

50 Hz

35 Hz

0 20 40 60 80 100 120 140 160 180 200 220

0

10

20

30

40

50

0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000

m³/h

Flow

US GPM

Wire to water eff. (%

)

45 Hz40 Hz

50 Hz

35 Hz30 Hz

30 Hz

65 Hz

60 Hz

55 Hz

55 Hz60 Hz65 Hz

Page 8: TECHNICAL DATA OW101H/4VV

Rev 1 ITIC

75kW / 100.5HP Poles 4 Date

305x50x30mm

PERFORMANCE CURVE OW101H‐4VV VX 75kW

Model

Impeller

DS‐A50‐190

5/13/2021

OW101H 75kW

PERFORMANCE CURVE OW101H‐4VV VX 75kW

MotorTested with clean water

Test Standard : HI 11.6 Gr 3BSpecifications subject to change without notice

0 20 40 60 80 100 120 140 160 180 200 220

0

10

20

30

40

50

60

70

0

20

40

60

80

100

120

140

160

180

200

220

240

260

0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000

m³/h

m feet

US GPM

Total D

ynam

ic Head

0 20 40 60 80 100 120 140 160 180 200 220

0.0

20.0

40.0

60.0

80.0

0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000

m³/h

US GPM

Input P1 (kW

)

45 Hz40 Hz

50 Hz

35 Hz

0 20 40 60 80 100 120 140 160 180 200 220

0

10

20

30

40

50

0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000

m³/h

Flow

US GPM

Wire to water eff. (%

)

45 Hz40 Hz

50 Hz

35 Hz30 Hz

30 Hz

65 Hz

60 Hz55 Hz

55 Hz

60 Hz

65 Hz

70 Hz

70 Hz