Teledyne Analytical Instruments. TELEDYNE AAQMS Systems. Analytical Instruments for AQMS. CO – GFC7001E NO2 – 9110E SO2 – 6400E VOC – 4060 Ozone – 400E Particulate Matter (2.5 & 10) – Beta Ray Attenuation Zero Air Generator – 701 Mass Flow Calibrator – 702E DAS – Win collect . - PowerPoint PPT Presentation

Citation preview

Page 1: Teledyne Analytical Instruments

Teledyne Analytical Instruments

TELEDYNE AAQMS Systems

Page 2: Teledyne Analytical Instruments

2

Analytical Instruments for AQMS CO – GFC7001E

NO2 – 9110E SO2 – 6400E

VOC – 4060

Ozone – 400E

Particulate Matter (2.5 & 10) – Beta Ray Attenuation

Zero Air Generator – 701

Mass Flow Calibrator – 702E

DAS – Win collect

Page 3: Teledyne Analytical Instruments

3

NOx Analyzer - 9110 Chemiluminescence NO / NO2 / NOx Analyzer

USEPA RFNA-1194-099, CE

Page 4: Teledyne Analytical Instruments

4

NOx Analyzer - 9110 Chemiluminescence NO / NO2 / NOx Analyzer

USEPA RFNA-1194-099, CE

Ranges: 0-50 ppb to 0-20,000 ppb full scale, user selectable;

Independent NO, NO2, NOX ranges and auto ranging supported

Units: ppb, ppm, μg/m3, mg/m3

Zero noise: <0.2 ppb (RMS)

Span noise: <0.5% of reading (RMS) above 50 ppb or 0.2 ppb, whichever is greater

Lower Detectable Limit (LDL): 0.4 ppb

Zero drift: <0.5 ppb/24 hours, <1 ppb/7 days

Span drift: <0.5% /24 hours, <1% of reading/7 days

Lag time: 20 seconds

Rise and Fall time: <60 seconds to 95%

Linearity: 1% of full scale

Precision: 0.5% of reading

Sample flow rate: 500 cm3/min ±10%

Operating temp range: 5 - 40°C

Page 5: Teledyne Analytical Instruments

5

9110E NOx - Schematic

Page 6: Teledyne Analytical Instruments

6

NOx Analyzer - 9110

The Model 9110 Nitrogen Oxides Analyzer uses chemiluminescence detection, coupled with state-of-the-art microprocessor technology to provide the sensitivity, stability and ease of use needed for ambient or dilution CEM monitoring requirements of nitric oxide (NO), nitrogen dioxide (NO2) and the total nitrogen oxides (NOx).

The Process:

1. The 9110 calculates the amount of NO present by measuring the amount of chemiluminescence given off when the sample gas is exposed to ozone (O3).

2. A catalytic-reactive converter converts any NO2 in the sample gas to NO, which is then measured as above (including the original NO in the sample gas) and reported as NOx.

3. NO2 is calculated as the difference between NOX and NO.

Since the density of the sample gas effects the brightness of the chemiluminescence reaction, the software compensates for temperature and pressure changes.

Page 7: Teledyne Analytical Instruments

7

NOx Analyzer - 9110

Auto-Zero

Stability is further enhanced by an Auto-Zero feature which periodically redirects the gas flow through the

analyzer so that no chemiluminescence reaction is present in the sample chamber. The analyzer measures this‘dark” condition and uses the results as an offset, which is subtracted from the sensor readings recorded while the instrument is measuring NO and NOX. The result gives a sensitive, accurate, and dependable performance under the harshest operating conditions.

Software features:

The M200E analyzer’s multi-tasking software gives the ability to track and report a large number of operational parameters in real time. These readings are compared to diagnostic limits, should any fall outside of those limits the analyzer issues automatic warnings. Using the analyzer's internal memory, allows the logging of multiple parameters including averaged or instantaneous concentration values, calibration data, and operating parameters such as pressure and flow rate.

Page 8: Teledyne Analytical Instruments

8

NOx Analyzer - 9110

Exceptional features Ranges, 0-50 ppb to 0-20 ppm, user selectable

Independent ranges for NO, NO2, NOX

Multi-tasking software allows viewing test variables while operating

Continuous self checking with alarms

Permeation dryer on ozone generator

Dual bi-directional RS-232 ports for remote operation (optional RS-485 or Ethernet)

Digital status outputs provide instrument operating condition

Temperature & Pressure compensation

Converter efficiency correction software

Catalytic ozone scrubber

Page 9: Teledyne Analytical Instruments

9

NOx Analyzer - 9110

Figure 3-4: Pneumatic Diagram – Basic 9110 p32*

Figure 3-3: Internal Layout – Top View with IZS Option p31*

PMT:Photo-Multiplier Tube IZS: Internal Zero /Span GLOSSARY p55*

The chemiluminescence method for detecting NOX is subject to interference from a number of sources including water vapor (H2O), ammonia (NH3), sulfur dioxide (SO2) and carbon dioxide (CO2) but the M200E has been designed to reject most of these interferences. Ammonia3 is the most common interferent, which is converted to NO in the analyzer’s NO2 converter and creates a NOX signal artifact.If the M200E is installed in an environment with high ammonia, steps should be taken to remove the interferent from the sample gas before it enters the reaction cell. Teledyne API offers a sample gas conditioning option to remove ammonia and water vapor

Carbon dioxide diminishes the NOX signal when present in high concentrations.

The analyzer should not be used in an application with excess CO2,

Excess water vapor can be removed with one of the dryer options described in Section 6.8. In ambient air applications, SO2 interference is usually negligible.

* Pages of the data sheet

Page 10: Teledyne Analytical Instruments

10

NOx Analyzer - 9110

COMMUNICATION OPTIONSRS-232 MODEM CABLE (OPTION 60A)RS-232 MULTIDROP (OPTION 62) is used with RS232 and utilizes both DB-9 connectors on the rear panel to enable communications of up to eight analyzers with the host computer over a chain of RS-232 cables.ETHERNET (OPTION 60C)ETHERNET + MULTIDROP This option allows the instrument to communicate on both RS-232 and ETHERNET networks simultaneously. It includes the following: RS-232 MULTIDROP (OPT 62) ETHERNET (OPT 60C)CONCENTRATION RELAY ALARM (OPTION 61) NO Alarm 1 = 20 PPM NO Alarm 2 = 100 PPM NO2 Alarm 1 = 20 PPM NO2 Alarm 2 = 100 PPM

Page 11: Teledyne Analytical Instruments

11

NOx Analyzer - 9110SPECIAL FEATURES

1. DILUTION RATIO OPTION

The Dilution Ratio Option is a software option that is designed for applications where the Sample gas is diluted before being analyzed. Typically this occurs in Continuous Emission Monitoring (CEM) applications where the quality of gas in a smoke stack is being tested and the sampling method used to remove the gas from the stack dilutes the gas. Once the degree of dilution is known, this feature allows the user to add an appropriate scaling factor to the analyzer’s CO concentration calculation so that the Measurement Range and concentration values displayed on the instrument’s Front Panel Display and reported via the Analog and Serial Outputs reflect the undiluted values.

2. MAINTENANCE MODE SWITCH

The instruments can be equipped with a switch that places the instrument in maintenance mode. When present, the switch is accessed by opening the hinged front panel and is located on the rearward facing side of the display/keyboard driver PCA, on the left side, near the particulate filter. When in maintenance mode the instrument ignores all commands received via the COMM ports that alter the operation state of the instrument.

Page 12: Teledyne Analytical Instruments

12

NOx Analyzer - 9110

3. SECOND LANGUAGE SWITCHAPI’s instruments can be equipped with a switch that activates an alternate set of display message in a language other than the instrument’s default language. To activate this feature, the instrument must have a specially programmed Disk-on-Module (DOM) containing the second language.

Page 13: Teledyne Analytical Instruments

13

NOx Analyzer - 9110

ELECTRO-STATIC DISCHARGE

Modern electronic devices such as the types used in the various electronic assemblies of your analyzer, are very small, require very little power and operate very quickly. Unfortunately, the same characteristics that allow them to do these things also make them very susceptible to damage from the discharge of static electricity.

Damage to components occurs when these static charges come into contact with an electronic device.

Temporary anti-ESD work area Always wear an Anti-ESD wrist strap when working on the electronic assemblies of

your analyzer.

Simply touching a grounded piece of metal is insufficient. While this may temporarily bleed off static

Always store sensitive components and assemblies in anti-ESD storage bags or bins

Page 14: Teledyne Analytical Instruments

TELEYNE Team Thank you All

Company Confidential

Company Headquarters: City of Industry, California USA

Facility: 60,000 sq. ft. / ISO-9001:2008

Founded: 1945

Core Capabilities: Manufacturer of high quality measurement and control instrumentation.

Website: www.teledyne-ai.com