    Operating instructionsBetriebsanleitung

    Head mounting version Rail mounting version model T32.10 model T32.30

    Temperature transmitters models T32.10, T32.30

    Temperatur-Transmitter Typen T32.10, T32.30

  • 22

    D

    GB Operating instructions models T32.10, T32.30 Page 3 - 46

    Betriebsanleitung Typen T32.10, T32.30 Seite 47 - 87

    WIKAAlexanderWiegandSE&Co.KG2010

    Priortostartinganywork,readtheoperatinginstructions!Keepforlateruse!

    VorBeginnallerArbeitenBetriebsanleitunglesen!ZumspterenGebrauchaufbewahren!

    WIKAoperatinginstructionstemperaturetransmittersT32.10,T32.30

    2383336.1309/2010GB/D

  • WIKAoperatinginstructionstemperaturetransmitterT32.10,T32.30

    Contents

    1. General information 42. Safety 63. Specifications 134. Design and function 145. Transport, packaging and storage 156. Commissioning, operation 167. Notes for operating in safety-related

    applications (SIL) 258. WIKA T32 configuration software 269. Electrical connections 2910. Notes for mounting and operating in

    hazardous areas 3411. Further country-specific approvals 3912. Maintenance 3913. Faults 4014. Return and disposal 41Appendix 1: CSA Installation drawing 43Appendix 2: FM Installation drawing 44Appendix 3: EC Declaration of conformity 45

    Contents2383336.1309/2010GB/D

    GB

    3

  • WIKAoperatinginstructionstemperaturetransmittersT32.10,T32.30

    1. General information Thetemperaturetransmitterdescribedintheoperatinginstruc-tionshasbeendesignedandmanufacturedusingstate-of-the-arttechnology.Allcomponentsaresubjecttostringentqualityandenvironmentalcriteriaduringproduction.OurmanagementsystemsarecertifiedtoISO9001andISO14001.

    Theseoperatinginstructionscontainimportantinformationonhandlingthetemperaturetransmitter.Workingsafelyrequiresthatallsafetyinstructionsandworkinstructionsareobserved.

    Observethelocalaccidentpreventionregulationsandgeneralsafetyregulations,ineffectforthetemperaturetransmittersrangeofuse.

    Theoperatinginstructionsarepartoftheinstrumentandmustbekeptintheimmediatevicinityofthetemperaturetransmitterandreadilyaccessibletoskilledpersonnelatanytime.

    Skilledpersonnelmusthavecarefullyreadandunderstoodtheoperatinginstructions,priortobeginninganywork.

    Themanufacturersliabilityisvoidinthecaseofanydamagecausedbyusingtheproductcontrarytoitsintendeduse,non-compliancewiththeseoperatinginstructions,assignmentofinsufficientlyqualifiedskilledpersonnelorunauthorisedmodifica-tionstothetemperaturetransmitter.

    Thegeneraltermsandconditions,containedinthesalesdocumentation,shallapply.

    Subjecttotechnicalmodifications.

    Furtherinformation:-Internetaddress: www.wika.de/www.wika.com-Relevantdatasheet: TE32.03-Applicationconsultant: Tel.: (+49)9372/132-0

    Fax: (+49)9372/132-406E-Mail: [email protected]

    1. General information

    2383336.1309/2010GB/D

    GB

    4

  • WIKAoperatinginstructionstemperaturetransmitterT32.10,T32.30

    Explanation of symbols

    WARNING!...indicatesapotentiallydangeroussituation,whichcanresultinseriousinjuryordeath,ifnotavoided.

    CAUTION!...indicatesapotentiallydangeroussituation,whichcanresultinlightinjuriesordamagetoequipmentortheenvironment,ifnotavoided.

    Information...pointsoutusefultips,recommendationsandinforma-tionforefficientandtrouble-freeoperation.

    DANGER!...identifieshazardscausedbyelectricalpower.Shouldthesafetyinstructionsnotbeobserved,thereisariskofseriousorfatalinjury.

    WARNING!...indicatesapotentiallydangeroussituationinapotentiallyexplosiveatmosphere,resultinginseriousinjuryordeath,ifnotavoided.

    1. General information2383336.1309/2010GB/D

    GB

    5

  • WIKAoperatinginstructionstemperaturetransmittersT32.10,T32.30

    2. SafetyWARNING!Beforeinstallation,commissioningandoperation,ensurethattheappropriatetemperaturetransmitterhasbeenselectedintermsofmeasuringrange,designandspecificmeasuringconditions.Seriousinjuriesand/ordamagecanoccurshouldthesenotbeobserved.

    WARNING!ThisisProtectionClass3equipmentforconnectionatlowvoltages,whichareseparatedfromthepowersupplyorvoltagebygreaterthan50VACor120VDC.Preferably,aconnectiontoanSELVorPELVcircuitisrecommended;alternativelyprotectivemeasuresfromHD60346-4-41(DINVDE0100-410).AlternativelyforNorthAmerica:Theconnectioncanbemadeinlinewith"Class2Circuits"or"Class2PowerUnits"inaccordancewithCEC(CanadianElectricalCode)orNEC(NationalElectricalCode)

    Furtherimportantsafetyinstructionscanbefoundintheindividualchaptersoftheseoperatinginstructions.

    2.1 Intended useTheModelT32.10/30temperaturetransmitterisauniversal,configurabletransmitterforusewithresistancethermometers(RTD),thermocouples(TC)aswellasresistanceandvoltagesources.

    Thetemperaturetransmitterhasbeendesignedandbuiltsolelyfortheintendedusedescribedhere,andmayonlybeusedaccordingly.

    2. Safety

    2383336.1309/2010GB/D

    GB

    6

  • WIKAoperatinginstructionstemperaturetransmitterT32.10,T32.30

    Thetechnicalspecificationscontainedintheseoperatinginstructionsmustbeobserved.Shouldtheinstrumentbeimproperlyhandledoroperatedoutsideofitstechnicalspecifications,itshouldbeshutdownimmediatelyandinspectedbyanauthorisedWIKAserviceengineer.

    Ifthetemperaturetransmitteristransportedfromacoldintoawarmenvironment,theformationofcondensationmayresultintheinstru-mentmalfunctioning.Beforeputtingitbackintooperation,waitfortheinstrumenttemperatureandtheroomtemperaturetoequalise.

    Themanufacturershallnotbeliableforclaimsofanytypebasedonoperationcontrarytotheintendeduse.

    2.2 Personnel qualification

    WARNING!Risk of injury should qualification be insufficient!Improperhandlingcanresultinconsiderableinjurytopersonnelanddamagetoequipment. Theactivitiesdescribedintheseoperatinginstruc-tionsmayonlybecarriedoutbyskilledpersonnelwhohavethequalificationsdescribedbelow. Keepunqualifiedpersonnelawayfromhazardousareas.

    Skilled personnelSkilledpersonnelareunderstoodtobepersonnelwho,basedontheirtechnicaltraining,knowledgeofmeasurementandcontroltechnologyandontheirexperienceandknowledgeofcountry-specificregula-tions,currentstandardsanddirectives,arecapableofcarryingouttheworkdescribedandindependentlyrecognisingpotentialhazards.

    Specialoperatingconditionsrequirefurtherappropriateknowledge,e.g.ofaggressivemedia.

    2. Safety2383336.1309/2010GB/D

    GB

    7

  • WIKAoperatinginstructionstemperaturetransmittersT32.10,T32.30

    2.3 Additional safety instructions for instruments with ATEX approval

    WARNING!Non-observanceoftheseinstructionsandtheircontentsmayresultinthelossofexplosionprotection.

    WARNING! ObservetheapplicableregulationsfortheuseofEx-classinstruments(e.g.:EN60079-0:2006,EN60079-11:2007,EN60079-26:2007,EN60079-27:2006+2008,EN61241-0:2006,EN61241-11:2006,EN60079-15:2005) Donotusetransmitterswithanydamagetotheexterior! Wheninstallationinsafety-relatedapplications,observethenotesforfunctionalsafety(seechapter"7.Notesforoperatinginsafety-relatedapplications").

    2.4 Special hazards

    WARNING!Observetheinformationgivenintheapplicabletypeexaminationcertificateandtherelevantcountry-specificregulationsforinstallationanduseinpotentiallyexplo-siveatmospheres(e.g.IEC60079-14,NEC,CEC).Non-observancecanresultinseriousinjuryand/ordamagetoequipment.ForadditionalimportantsafetyinstructionsforinsturmentswithATEXapprovalseechapter"2.3AdditionalsafetyinstructionsforinstrumentswithATEXapproval".

    2. Safety

    2383336.1309/2010GB/D

    GB

    8

  • WIKAoperatinginstructionstemperaturetransmitterT32.10,T32.30

    WARNING!ThefunctionalgalvanicisolationpresentintheinstrumentdoesnotensuresufficientprotectionagainstelectricalimpulsesinthesenseofEN61140.

    WARNING! Forhazardousmediasuchasoxygen,acetylene,flamma-bleortoxicgasesorliquids,andrefrigerationplants,compressors,etc.,inadditiontoallstandardregulations,theappropriateexistingcodesorregulationsmustalsobefollowed.

    WARNING!Toensuresafeworkingontheinstrument,theoperatormustensure thatsuitablefirst-aidequipmentisavailableandaidisprovidedwheneverrequired. thattheoperatingpersonnelareregularlyinstructedinalltopicsregardingworksafety,firstaidandenviron-mentalprotectionandknowtheoperatinginstructionsand,inparticular,thesafetyinstructionscontainedtherein.

    WARNING! Whenworkingduringarunningprocessoperation,measurestopreventelectrostaticdischargefromtheconnectingterminalsshouldbetaken,asadischargecouldleadtotemporarycorruptionofthemeasuredvalue.

    2. Safety2383336.1309/2010GB/D

    GB

    9

  • WIKAoperatinginstructionstemperaturetransmittersT32.10,T32.30

    TheModelT32.10temperaturetransmittershouldonlybeusedwithgroundedthermometers!Theconnectionofaresistancethermometer(e.g.Pt100)totheT32.30mustbemadewithshieldedcable.Theshieldmustbeelectricallyconnectedwiththehousingofthegroundedthermometer.

    TheconnectionofathermocouplesensortotheT32.10mustbemadewithascreenedcable.Theshieldmustbeelectricallyconnectedwiththehousingofthegroundedthermometerand,additionally,groundedtothesideoftheT32.10.Itshouldbeensuredthatthereisequipoten-tialbondingoninstallation,sothatnobalancingcurrentcanflowviatheshield.Here,inparticular,theinstallationregulationsforhazardousareasshouldbefollowed!

    DANGER!Danger of death caused by electric currentUponcontactwithliveparts,thereisadirectdangerofdeath. Electricalinstrumentsmayonlybeinstalledandmountedbyskilledelectricalpersonnel. Operationusingadefectivepowersupplyunit(e.g.shortcircuitfromthemainsvoltagetotheoutputvoltage)canresultinlife-threateningvoltagesattheinstrument!

    WARNING!Onlyinstrumentsasdescribedinchapter"4.2Operationinsafety-relatedapplications"arequalifiedforuseinsafety-relatedapplications.DonotuseotherinstrumentsinsafetyorEmergencyStopdevices.Incorrectuseoftheinstrumentcanresultininjury.

    2. Safety