19
TEST GRAINS AS A NOVEL DIAGNOSTIC TOOL B.W. James, A.A. Samarian and W. Tsang School of Physics, University of Sydney NSW 2006, Australia B.James@physics. usyd .edu.au

TEST GRAINS AS A NOVEL DIAGNOSTIC TOOL

  • Upload
    deion

  • View
    31

  • Download
    0

Embed Size (px)

DESCRIPTION

TEST GRAINS AS A NOVEL DIAGNOSTIC TOOL. B.W. James, A.A. Samarian and W. Tsang School of Physics, University of Sydney NSW 2006, Australia [email protected] ICPP Sydney 2002. What is a dusty plasma?. - PowerPoint PPT Presentation

Citation preview

Page 1: TEST GRAINS AS A NOVEL DIAGNOSTIC TOOL

TEST GRAINS AS A NOVEL DIAGNOSTIC TOOL

B.W. James, A.A. Samarian and W. Tsang

School of Physics, University of Sydney

NSW 2006, [email protected]

ICPP Sydney 2002

Page 2: TEST GRAINS AS A NOVEL DIAGNOSTIC TOOL

What is a dusty plasma?

• a low temperature plasma containing small particles of diameters in nanometer and micrometer range

• particles acquire a net negative charge (at equilibrium floating potential)

• particles levitated in sheaths where electric force balances gravity

• particles can form liquid- and solid- like arrays (plasma or Coulomb crystal) which can undergo phase transitions

Page 3: TEST GRAINS AS A NOVEL DIAGNOSTIC TOOL

Forces on dust particle in plasma sheath

E

vi

rf powered electrode

radius = acharge = Zd

sheathboundary

heq

hb

FE, Fth

Fg, Fi

ions

z

Figure 1: Schematic diagram of dust particle in plasma sheath

Page 4: TEST GRAINS AS A NOVEL DIAGNOSTIC TOOL

Forces on a dust particle

• Electric force

• Gravity force

• Ion drag force

• Thermophoretic force

FE Zd E

Fg 4

3a3g

Fi a2nimiv i2 1

eZ d

amivi2

Fth 32

15

m

8Ta2

T

z

Page 5: TEST GRAINS AS A NOVEL DIAGNOSTIC TOOL

where– a is particle radius– is particle density– Zde is charge on particle– mi is ion mass– ni is ion density– vi in ion velocity in sheath– Te is electron temperature– T is gas temperature– m is mass of gas atoms– is thermal conductivity of plasma

Page 6: TEST GRAINS AS A NOVEL DIAGNOSTIC TOOL

Experimental arrangement

Dust particles

Grounded electrode

Powered electrode

Figure 2: Experimental chamber and image of test dust particles levitated above the electrode. The test grains are generated in the discharge (power up to 200W, pressure up to 1 torr) by electrode sputtering.

Page 7: TEST GRAINS AS A NOVEL DIAGNOSTIC TOOL

Equilibrium position of dust particleUsing the force balance equation,

FE + Fg + Fi + Fth = 0 the equilibrium position has been calculated as a

function of radius a (see figure 3) using following assumptions– Vs ~ 60 V, linear variation of electric field in sheath– vi from sheath model– Te ~ 2 eV– R = 2 g cm-3

– dT/dz ~ 1-5 K cm-1 (varying with input power)– Zd calculated from OML theory

Page 8: TEST GRAINS AS A NOVEL DIAGNOSTIC TOOL

Equilibrium position vs. radius

0

0,1

0,2

0,3

0,4

0,5

0 0,5 1 1,5 2 2,5 3

Dust radius, m

(hb-heq)/hb

Figure 3: Equilibrium height of dust particles above electrode heq, relative to height of sheath boundary hb as a function particles radius for several values of ion plasma frequency,

i = 106 s-1 (dashed) 5x106 s-1 (dotted), 107 s-1 (solid),

i 4nie2 / mi

Page 9: TEST GRAINS AS A NOVEL DIAGNOSTIC TOOL

Alternative estimates of sheath width

0

0,5

1

1,5

2

2,5

3

0 2 4 6 8 10 12 14 16 18 20

h, mm

T, eV I, a.u.1

0.5

heq

Figure 4: Electron temperature Te (points with error bars) measured using

Langmuir probe; discharge emission (solid line); the dashed line shows the equilibrium position (heq =10.8 mm) of test grains (a~350 nm). Discharge

conditions: p = 90m Torr, P = 80 W.

Page 10: TEST GRAINS AS A NOVEL DIAGNOSTIC TOOL

0

5

10

15

20

25

30

0 10 20 30 40 50 60 70 80 90 100

Pressure (mTorr)

hb(mm)

Position of sheath edge (Position of sheath edge (hhbb) vs pressure at different rf-input powers) vs pressure at different rf-input powers

– 35W

– 60W

– 100W

Sheath width as function of pressure

Page 11: TEST GRAINS AS A NOVEL DIAGNOSTIC TOOL

Visualisation of rf sheath

• Sufficiently small particles cannot achieve force equilibrium in the sheath - the sheath becomes a particle-free region

• Particles occupy pre-sheath and positive column

• Provides a visualisation of the sheath-plasma boundary - see Figure 5

Page 12: TEST GRAINS AS A NOVEL DIAGNOSTIC TOOL

Figure 5:The shape of the potential well above the confiningelectrode in a radio-frequency (rf) discharge with aprinted-circuit board electrode system (Cheung et al.,2002) was visualised using fine dust grains that weregenerated in the discharge. The well shape wasfound to depend strongly on the confining potential

QuickTime™ and aPhoto - JPEG decompressor

are needed to see this picture.

Page 13: TEST GRAINS AS A NOVEL DIAGNOSTIC TOOL

Particle Particle Driving PadDriving Pad

ParticleParticleDispenserDispenser

Top GroundTop GroundElectrodeElectrode

Gas InletGas Inlet

RF Supply15MHz

AC PowerPin ElectrodesPin Electrodes

DC Power

Side ObservationSide ObservationWindowWindow

Top ObservationTop ObservationWindowWindow

dZ

svFsvFsma 2211 )()(

1s2s

a

1v2v

vavmnFnTn

2

3

4

Transient motion technique

where

)(rf

Top View

'

20 )2(

E

mfZD

0fWhere is the resonant frequency'EAnd is the electric field gradient

Page 14: TEST GRAINS AS A NOVEL DIAGNOSTIC TOOL

Effect of hot electrons in sheath

Rd ~ h heq

eqhh

Figure 6: Square root of distance of particle from sheath edge as a function of particle radius

Page 15: TEST GRAINS AS A NOVEL DIAGNOSTIC TOOL
Page 16: TEST GRAINS AS A NOVEL DIAGNOSTIC TOOL
Page 17: TEST GRAINS AS A NOVEL DIAGNOSTIC TOOL

Particle Data

Probe Data

Figure 7: Potential profile measured by a Langmuir probe, and by transient motion analysis

Page 18: TEST GRAINS AS A NOVEL DIAGNOSTIC TOOL

Conclusions

• as particle radius decreases, equilibrium position moves closer to edge of sheath

• sufficiently small particles avoid sheath region, occupying pre-sheath and positive column. providing visualisation of sheath

• hot electrons affect equilibrium position• potential and electric filed profiles determined from transient

motion analysis

AcknowledgementsThis work is supported by the Australian Research Council and the Science Foundation for Physics within the University of Sydney

ReferencesA.A. Samarian and B.W. James, Phys Letters A, 287 (2001) 125F. Cheung, A. Samarian and B. James, Physica Scripta, T98 (2002) 143-5

Page 19: TEST GRAINS AS A NOVEL DIAGNOSTIC TOOL

Particle Data

Probe Data

Least Mean Square Fit for Particle Data

Least Mean Square Fit for Probe Data

Figure 8:Radial electric fieldderived from resultsin figure 7.