8
TS samples at a laboratory scale of: etritiation technique n : r removal ellations treatments control and removal thermal response of layers (layer characterisation Laser Induced Breakdown Spectroscopy (LIBS) ayer composition) sive Goal : the installation of these techniques on the AIA H. Roche , C Grisolia

Tests on TS samples at a laboratory scale of: 1.Laser detritiation technique focus on : layer removal Castellations treatments Dust control and removal

Embed Size (px)

Citation preview

Page 1: Tests on TS samples at a laboratory scale of: 1.Laser detritiation technique focus on : layer removal Castellations treatments Dust control and removal

Tests on TS samples at a laboratory scale of:

1. Laser detritiation technique focus on :• layer removal • Castellations treatments• Dust control and removal

2. Test of thermal response of layers (layer characterisation)

3. Test of Laser Induced Breakdown Spectroscopy (LIBS) (layer composition)

Comprehensive Goal :• Prepare the installation of these techniques on the AIA

H. Roche, C Grisolia

Page 2: Tests on TS samples at a laboratory scale of: 1.Laser detritiation technique focus on : layer removal Castellations treatments Dust control and removal

Ab so rb e ur

La se r fib ré p ulsé Ytte rb ium

Alim . la se r 24V 10A

Un ité c o ntrô le / c o m m a nd e la se r

Alim e n ta tio n & c o ntrô leTê te g a lva X - Y

PC d e c o ntrô le - c o m m a nd e

M o nite u r d e c o ntrô le

M iro ir 99%

C C D d e visua lisa tio n

Tê te g a lva . X - Y

Aig uille LPT

Ablation, thermal response & LIBS: lab studies (resp. H Roche)

Ablation:System already existing(first trials in 3-4 months)To be coupled with characterisation (X Courtois)

Thermal response:Detector etc. ok Need to be installed And tested(on-going effort in Saclay)

LIBS:Need of spectrometer(could be borrow from Saclay)Need to be installed And tested

Pyrometer

Page 3: Tests on TS samples at a laboratory scale of: 1.Laser detritiation technique focus on : layer removal Castellations treatments Dust control and removal

Needs

• 2 LPT fingers needed with deposited areas (bridges welcome)

• No need of hardware except for LIBS (spectro to be borrowed)

• Very small budget in 2007 (less than 5 k€)

• PPY : ok (at least 6 months of work)

Page 4: Tests on TS samples at a laboratory scale of: 1.Laser detritiation technique focus on : layer removal Castellations treatments Dust control and removal

AblationCEA (Saclay), UKAEA, TEKES

Page 5: Tests on TS samples at a laboratory scale of: 1.Laser detritiation technique focus on : layer removal Castellations treatments Dust control and removal

Thermal response (layer characterisation)CEA Saclay, CEA Cadarache

Page 6: Tests on TS samples at a laboratory scale of: 1.Laser detritiation technique focus on : layer removal Castellations treatments Dust control and removal

Thermal response (layer characterisation)tests of layer removal in Tore Supra foreseen in 2007 couple with lock in thermography studies.Procedure : lock in characterisation + laser ablation + lock in characterisation

alim. laser 24V 10A Unité contrôle/ commande laser alim.

CCD

Hall Tore

Enceinte de Tore Supra

Bâti intermédiaire

Plaque de protection

laser

miroir

Tête galvano-métrique

aiguilles

poutre

Camera CCD

Bâti fixe

laser pulsé fibré Ytterbium

Moniteur de contrôle Carte et alimentation

de la tête galvano-métrique

Page 7: Tests on TS samples at a laboratory scale of: 1.Laser detritiation technique focus on : layer removal Castellations treatments Dust control and removal

LIBS (layer composition + feedback control on the ablation process)

CEA SaclayOngoing studies at JET

Page 8: Tests on TS samples at a laboratory scale of: 1.Laser detritiation technique focus on : layer removal Castellations treatments Dust control and removal

AIA

Detritiation +Heating +LIBSTool(s)