THE FLOOR IS THE JOINT,

THE JOINT IS THE FLOOR

Cosinus Slide jointSetting the standard

®

THE CHALLENGEFOR JOINTSIN INDUSTRIALFLOORS

CONTROLLINGDYNAMIC &

MADE IN BELGIUM

Contact us for a free design check

Hengelhoefstraat 158, 3600 Genk, Belgium

+32(0)89 32 39 80 [email protected]

STATICLOADS

Page 2: THE CHALLENGE FOR JOINTS IN INDUSTRIAL FLOORS … · Make sure you select the right joint with our services 2012 COSINUS SLIDE® JOINTS 80s TRADITIONAL STRAIGHT JOINTS < 80s SAW CUTS

2020

DYNAMIC LOAD TRANSFER PERFORMANCE

STATIC LOAD TRANSFER PERFORMANCE

VERYPOOR

VERYPOOR POOR

GOODSINGLE

Slide e�ect

SUPERIORDOUBLE

Slide e�ectCONTROL

DESIGNSUPERIORLIMITEDLIMITED

The missing linkand final stepfor ultimate

jointingsolutions

Make sure you select the right jointwith our services

2012

COSINUS SLIDE® JOINTS

80s

TRADITIONALSTRAIGHT JOINTS

< 80s

SAW CUTS

*We estimate that 75% of all installed joints are unable to meet the minimum requirement of a 40+% load transfer. Most jointing solutions cannot deliver more than a 30% load transfer, which is simply not enoughfor today’s requirements. This means that the vast majority of floors today are underdesigned and expected to trigger repair, floor deformations, warehouse floor down-time and personnel absenteeism.

Is your joint up to the challenge?

THE MARKET INNOVATORSDYNAMIC LOAD STATIC LOADTRANSFER CHALLENGE TRANSFER CHALLENGE

Cosinus Slide55% 45%

Reality75% of industrial floorsunderdesigned* 70% 30%

40% Load transfer standard assumption in the flooring industry

®

Perfection was achieved with Cosinus Slide® jointand its double slide e�ect

HCJ solved the problem with its Sinus Slide® joint

Check your jointperformance

Get a full designcheck by HCJ

expertsSubmit your design

specs to the tool

1 2 3

Visciouss circle of damage and discomfort caused by wheel impact

2007

SINUS SLIDE JOINTS®

HIGHER RACKS +CLOSER TOGETHER= HIGHER LOADS

Page 3: THE CHALLENGE FOR JOINTS IN INDUSTRIAL FLOORS … · Make sure you select the right joint with our services 2012 COSINUS SLIDE® JOINTS 80s TRADITIONAL STRAIGHT JOINTS < 80s SAW CUTS

With the introduction of the load transfer performance calculator

HCJ enables any flooring professional to accurately select the right joints.

Influencingparameterson flooringdesigns

Loads

Concrete

Slab thickness

JOINT LOADTRANSFERMECHANISMIS OFTEN:

miss-understood

underestimated

wrongly consideredJOINTS

Subgrade

Reinforcement

SO FAR

2020

INTRODUCES

Contact us for a free design check

Hengelhoefstraat 158, 3600 Genk, Belgium +32(0)89 32 39 80 [email protected] www.hcjoints.be

Joint selectionbased on rules ofthumb or estimatesat best

25%of projects select the right joints

incomplete

probably wrong

unsafe

Flooring design

100%of projects canselect the rightjoints

Joint selectiondone based onaccurate loadtransfer assessment(TR34)

complete

optimized

correct & safe

Flooring design