Upload
hahanh
View
216
Download
2
Embed Size (px)
Citation preview
1
The Status of Coal-Fired Power Generation in TAIWAN
CHEN MAO-JING
Taiwan Power Research Institute
July 27,2009
2
CLASSIFICATION PERCENTAGE%NUCLEAR 19.60
OTHER THERMAL 76.20 HYDRO + WIND 4.20
Total installed capacity 38628MW
Power distribution in Taiwan
1
2
3
4
5
6
7
3
TalinNanpu
Hsinta
Taichung
Tunghsiao
Chienshan
HsiehhoShenao
Linkou P/PDatan
900 (Linkou)
2400(Linkou Retrofit,underImplementation)
5832(Taichung)
1600(Changgong,underImplementation)
1800(Malliao)
4326(Hsinta)
2400(Tallin)
3200(Tallin underImplementation)
Shenao 1600
The Status of Coal-Fired Power Plant in TAIWAN
Changgong
PresenterPresentation Notes
http://10.103.200.101/lk
4
POWER PLANT POWER SUPPLY (MWH) PERCENTAGE
(%) TCPS 42,300,650 21.12
OTHER PLANTS 157,940,266 78.88 TOTAL TPC
POWER SYSTEM 200,240,916 100
78.88%
21.12%TCPS
OTHERPLANTS
Percentage of Taichung Power Generation Comparing to Total Generation of TPC in 2008
5
2008 Installed Capacity Ratio of TPC Power System
84.90%
15.10%
TCPS
OTHER PLANTS
PresenterPresentation Notes2006.10
6
Taichung Thermal Power Plant
PresenterPresentation Notes
7
TypeN0. of Unit
Single Installed Cap.(MW)
Total Installed Cap.(MW)
Steam Turbine 10 550 5500
Gas Turbine 4 72 288Wind Power 22 2
44(under construction)
Total 5832MW
The Installed Capacity of TCPP
8
The Installed Capacity of Thermal Power Plant in The World
Power Plant Nation Capacity FuelTaichung(GT 288MW included)
ROC 5,788 Coal
Kawagoe Japan 4,802 LNGBoryeong Korea 4,800 Coal , LNGSurgut-2 Russia 4,800 LNGKashima Japan 4,400 OilBelchatow Porland 4,320 Oil,CoalHsinta ROC 4,300 Coal , LNG
9
Coal Transportation System
Coal is transported to the unloading wharf by coal ships and discharged via closed type conveyors to the coal storage area.
10
#1~#4 Foster Wheeler Co. U.S.A.
#5~#8 Babcock And Wilcox
#9~#10 Mitsui BabcockSteam Flow: 1,830 Tons/hrPressure189kg/cm2Temperature: 542Type: Radiation and
convection type of natural circulation balanced draft
Boiler
11
345KV SwitchyardManufacturer: Hitachi Japan in cooperation with Chung-hsing Electric and Machinery MFG Co. R.O.C.Function:Using SF6 as insulation and arc reducing medium.
345KV GIS Switchyard
12
Ratio of Environmental Protection Equipment to Total Investment
Item
Units
Total Investment
(billion NTD
Environmental Protection Equipment
billion NTD
Ratio of Environmental
Protection Equipment
#1 #8 149.24 28.24 18.9
#9#10(budget) 45.50 11.37 25.0
13
UNIT #1 2000.10.30 ~ 2002.1.1 427 DAYSUNIT #3 2007.3.8 ~ 2009.2.8 703 DAYSIt broke the record of our companyUNIT #4 2003.10.5 ~ 2005.3.4 517 DAYSUNIT #5 2001.12.11 ~ 2003.1.29 414 DAYSUNIT #6 2002.12.12 ~ 2004.5.5 511 DAYSUNIT #7 2006.6.19 ~ 2008.1.28 588 DAYSUNIT #8 2002.5.29 ~ 2004.1.5 587 DAYS
NoteThe world record is 782 days(Australia Tarong #2 in 2001)
Continuous Operation Record
14
39.80
39.78
39.839.8239.8839.80 39.76 39.76 39.85
39.7839.8139.69 39.61 39.74
39.78
39.3
38.8039.0039.2039.4039.6039.8040.0040.20
91 92 93 94 95 96 97
YEAR
PLANT EFF. TARGET PLANT EFF.
The Comparison of Plant Efficiency(LHV Gross)
15
Talin Power PlantTaiwan Power Company
Update:2009.07.15
16
Birds eye view of Kaohsiung Harbor
TALIN POWER PLANT
17
Equipment Introduction - Boiler
Made by Steam data Description
#1#2
MHIJAPAN
178kg/cm2
542 1000T/H
Forced circulationTangential firing
Balance draft
#3#4
MHIJAPAN
1200T/H
Pressurized furnace
#5MHI
JAPAN1700T/H
#6 B&WUSA
1829T/H nature circulation Radiant burner
18
Made by Steam turbine Generator
#1#2
WHUSA Throttle
press:169kg/cm2
Main/RH steam:538
Three casingTandem CompoundQuadruple-flow condensing Reheat type
3phases2poles60 Hz
353MVA24KV
H2 innercooledBrushless EXCITER
#3#4
MHIJAPAN
442MVA17.4KV
#5MHI
JAPAN590MVA18.4 KV
#6 GE
USA679MVA21.5KV
H2/ H2O innercooledBrush EXCITER
Equipment Introduction-TB & GEN
19
Japan
Europe
China USA
Development of Ultra Supercritical Units
1.Totalling 600 supercritical units in the world including USA 170,
Japan & Europe 60 each & Russia 280.
2.Totalling about 70 Ulta Supercritical Units in the world .
20
Hsinta Coal Unloading Improvement Project
21
NEW TALIN POWER PLANT
22
New Shenao power plant
23
New Linkou power plant
24
Coal Direct Chemical Looping Process study
(TPRI)
25
TALIN POWER PLANTCO2 reduction microalage feasibility study
(TPRI)
26
Ultra-supercritical boiler tube test rig
Flow rate: 150-400 kg/h
Pressure: 100-400 bar
Temperature: 50-720 C
Heating typical rate:50-150 C/h
Cooling typical rate:50-120 C/h
cation conductivity: 0.08 mS
27
THANK YOU
Slide Number 1Slide Number 2Slide Number 3Percentage of Taichung Power Generation Comparing to Total Generation of TPC in 20082008 Installed Capacity Ratio of TPC Power SystemSlide Number 6The Installed Capacity of TCPPThe Installed Capacity of Thermal Power Plant in The WorldCoal Transportation SystemBoiler345KV GIS SwitchyardRatio of Environmental Protection Equipment to Total InvestmentContinuous Operation RecordSlide Number 14Slide Number 15Slide Number 16Equipment Introduction - BoilerEquipment Introduction-TB & GENSlide Number 19Slide Number 20Slide Number 21Slide Number 22Slide Number 23Slide Number 24Slide Number 25Slide Number 26Slide Number 27