Upload
others
View
143
Download
1
Embed Size (px)
Citation preview
www.CircuitSolver.com1-877-379-8258
All CircuitSolver® Valves are NSF/ANSI 61 Certifi ed
ThermOmegaTech’s QMS is certifi ed to the AS9100 D Standards which includes ISO 9001:2015
Thermostatic Balancing ValvesFor Domestic Hot Water Systems
O� ered in a variety of sizes up to 2” with confi gurations including ball valves, integrated unions, check valves, strainers, and ProPress ends
CIRCUITSOLVER®
CS, CSU, CSUA, CSUAS & Accessories
The CircuitSolver® Union Assembly is offered with an integrated strainer for water systems with dirt or particulate to facilitate system start up and protect valve components and operation.
The CircuitSolver® Union is equipped with an integrated union and optional check valve to reduce the number of system components being installed. It features an integrated o-ring for a leak-free seal.
ThermOmegaTech’s standard thermostatic, self-actuating balancing valve, CircuitSolver®, adjusts the fl ow through a domestic hot water recirculation system to maintain a specifi ed return temperature at the end of each branch.
www.CircuitSolver.com | 1-877-379-8258 | 353 Ivyland Rd, Warminster, PA 18974
CircuitSolver® (CS)
CircuitSolver® Union Strainer Assembly (CSUAS)
CircuitSolver® Union (CSU)
CircuitSolver® Union Assembly (CSUA)The CircuitSolver® Union Assembly adds isolation ball valves on either end of the CSU. Assembled and leak tested prior to delivery, the CSUA makes it easier to install and service.
CircuitSolver® valves are offered with Viega ProPress® ends for seamless integration into ProPress Systems. Viega Smart Connect technology easily identifi es unpressed connection points, saving time and labor costs. The ProPress ends can be equipped to any CircuitSolver® confi guration.
CircuitSolver® with ProPress®
The CircuitSolver® thermometer monitors system temperature with an easy-to-read dial for instant hot water temperature verifi cation. Offered in ½”, ¾”, and 1” sizes, the thermometer assembly can be purchased in any CircuitSolver® confi guration or independently.
CircuitSolver® Thermometer Assembly
For product dimensions and specifi cations, submittals are available at: www.CircuitSolver.com/plumbingspecs
www.CircuitSolver.com | 1-877-379-8258 | 353 Ivyland Rd, Warminster, PA 18974
CIRCUITSOLVER®
Model Builders & CSUSF
The CircuitSolver® Sanitary Flush balances a domestic hot water system during normal operation and allows for higher water temperatures to fl ow through the system during a disinfecting process to protect against Legionella growth.
During model temperature selection, the fi rst temperature indicates the standard return line temperature and the second temperature indicates the maximum temperature during the sanitary fl ush process.
CircuitSolver® Sanitary Flush (CSUSF)
Model Selection:
CSUSF - - XXX/170 - - -
For product dimensions and specifi cations, submittals are available at: www.CircuitSolver.com/plumbingspecs
CV1 = check valve
Closing TemperatureLine sizes: ½”, ¾”, 1”
Examples:1. CSUSF installed on a ½” line with 120°F return temperature during standard usage and 170°F return temperature during high
temperature fl ush disinfection process: CSUSF-1/2-120/170.2. CSUSF with check valve and thermometer installed on a ¾” line with 115°F return temperature during standard usage and 170°F
return temperature during high temperature fl ush disinfection process: CSUSF-3/4-115/170-CV1-TW.
PP = ProPress ends
TW = thermometer
Model Selection:
CS - - XXX - - -
For product dimensions and specifi cations, submittals are available at: www.CircuitSolver.com/plumbingspecs
Blank = standard
A = assembly (2 integrated ball valves)
CV1 = check valve
S = strainer
Closing Temperature
Line Size
All styles: ½”, ¾”, 1”
CS Only: 1¼”, 1½”, 2”
Max. pressure: 200 PSIG (14 BAR)Max. temperature: 250°F (121°C)
Examples:1. Standard CircuitSolver® installed on a ½” line with 120°F return temperature: CS-1/2-1202. CircuitSolver® Union with check valve installed on a ¾” line with 115°F return temperature: CSU-3/4-115-CV13. CircuitSolver® Union Strainer Assembly installed on a 1” line with 130°F return temperature: CSUAS-1-130
PP = ProPress ends
TW = thermometer
Max. pressure: 200 PSIG (14 BAR)Max. temperature: 250°F (121°C)
U = integrated union
Blank = standard100°F (37.7°C)105°F (40.5°C)110°F (43.3°C)115°F (46.1°C)120°F (48.8°C)125°F (51.6°C)130°F (54.4°C)135°F (57.2°C)140°F (60.0°C)150°F (65.5°C)
Blank = standard
Blank = standard
Blank = standard
Blank = standard
Blank = standard
Blank = standard
Blank = standard100°F (37.7°C)105°F (40.5°C)110°F (43.3°C)115°F (46.1°C)120°F (48.8°C)125°F (51.6°C)130°F (54.4°C)135°F (57.2°C)140°F (60.0°C)
CircuitSolver® utilizes a thermal actuator to modulate the valve open and closed in response to temperature variations to control water fl ow through the CircuitSolver®. Installed in-line at the end of each branch before the return, the valve continually monitors water temperatures to direct hot water fl ow where it’s needed.
CircuitSolver®: Balancing In A Fraction of The Time
353 Ivyland Road 1-877-379-8258Warminster, PA 18974 www.CircuitSolver.com
CS BROCHUREREV: 5/1/20
CIRCUITSOLVER®
OUR TECHNOLOGY
How It Works
CircuitSolver® is a thermostatic, self-actuating balancing valve that automatically and continuously adjusts the fl ow through a domestic hot water recirculation system to maintain a specifi ed temperature at the end of each branch. This valve balances the system in a fraction of the time, eliminating time-consuming and expensive manual balancing labor during start-up and maintenance.
Z
TMVEXP.TANK
When the water temperature falls below the valve’s set-point, the CircuitSolver® modulates open to allow more water to fl ow to the return.
Why CircuitSolver®?• Temperature solution to a temperature problem
• Manufactured in the USA
• Lead free & NSF 61 Certifi ed
• Long service life & 3 year warranty
• Stainless steel - corrosion resistant
• Range of sizes ½”, ¾”, 1”, 1¼”, 1½” & 2”
• Array of confi gurations available
• Direct replacement for manual balancing
For product dimensions and specifi cations, submittals are available at: www.CircuitSolver.com/plumbingspecs
CircuitSolver® automatically adjusts fl ow in response to temperature changes and fl uctuations in demand, ensuring hot water at the turn of a tap and effectively eliminating callbacks.
As the water approaches the set-point temperature again, the CircuitSolver® automatically modules towards its closed position, allowing more water to fl ow to the other branches still in need of hot water.
The valve will never fully close, always allowing a small amount of bypass fl ow to avoid dead-heading the recirculation pump.This maintains a thermally balanced system that responds dynamically to varied usage rates throughout the day.
CircuitSolver® valves can also be used to balance the return fl ow between the master mixing valve and hot water heater.