TECHNICAL DATA SHEET
Imp
. So
uque
t - D
oc
ume
nt n
on
co
ntra
ctu
el -
Do
c IT
R/TH
ERM
O F
17 G
B -
10.0
9
CHARACTERISTICS THERMO•F17®
o 2 metallized and armed polyester sheets 127 g/m2
Composition o 4 thicknesses of wadding 80 g/m2
o 6 metallized polyester sheets 20 µ o 5 thicknesses of foam 0,8 mm
Thickness + 33 mm
Size 1,50 x 10 ml = 15 m2
Weight of the roll + 10 kg
Stability temperature -40° C / + 80° C
Reflectivity + 95 %
Tensile strength L = 250 N / mm2 • D = 270 N /mm2
The methods of calculation used for defining the installation value (value R) appears to be barely appropriate to reflection integrators. By tacking into consideration the various modes of energy Thermal equivalence transfer and by placing at the installation between two air graps, we have a thermal barrier against heat and cold and we obtain results of saving energy as a thick insulating material of roofing bigger 200 mm acting by absorption according try in situ.
Acoustic The acoustic attenuation indices referred to installation between two air attenuation gaps + concrete tiles doubled of the roof.
Thickness +
33 mm
17 elements
+ 37 dbIsolant ITR®
Tuile
Contre-Liteau
Chevron
Fixation courte pour rails F530
Ventilation> 40 mm
Tasseau
Vide d'air > 40 mm
Cloison
Isolant ITR®
Plaque de plâtre
Revêtement Plinthe Isolant ITR®
Isolant ITR®
Isolant ITR®
Tuile
Contre-Liteau
Chevron
Fixation courte pour rails F530
Ventilation> 40 mm
Tasseau
Vide d'air > 40 mm
Cloison
Isolant ITR®
Plaque de plâtre
Revêtement Plinthe Isolant ITR®
Isolant ITR®
LAYING INSTRUCT IONS
ITR® insulation
Tile
Counter lath
Rafter
Ventilationair gap > 40 mm
Empty of air > 40 mm
Dividing wall
Plaster board
CoatingPlinth
ITR® insulation
ITR® insulation
ITR® insulation
■ For the use of all of our products, it is essential to provide an overlapping of the widths between one another over a minimum of 50mm to prevent forming any thermal bridges. To ensure total tightness, cover with ALUDESIF adhesive.
■ Be sure to comply with the applicable standards regarding the ventilation of the roof.Good installation requires good ventilation.
■ Do not allow the product to come into contact with any source of electricity.
ADVANTAGES
Thermal and acoustic insulation constant in time winter as summer
Resistant and unchangeable
Tight against air and run off water
Not harmful, not irritation and allergenic
Optimum gain in volume and space
Participate of savings energy and contribute to preserve ozone layer
Laying on new roof or renovation, on wall and under frame
Laying on the new roof
Laying on the roof
Laying under roof
Installation against wall
R = 2.36 m²K/W(BBA test report n°47726THC
BS EN 12667)