Keep this guide for future reference ©2014 Powersoft | | AC mains supply The following operations can be performed only by professional or qualified personnel according to local electrical authorities guidelines. Refer to the user manual for security and proper installation instructions AC mains connection is provided by means of the euroblock Phoenix PC 5/5- STF1-7,62 connector and flying plug (Phoenix product ID 1777862). Proper assembly of the AC mains conductors to the flying plug must respect the power line configuration; recommended wires section is 2,5 mm 2 / 13 AWG. This device must be powered exclusively by earth connected mains sockets in electrical networks compliant to the IEC 364 or similar rules. Since the main power switch on this unit does not provide a complete insula- tion of the equipment from the mains power, you must disconnect the main power source to turn off all power. Provide a sectioning breaker between the mains connections and the amplifier. The correct device to use depends on mains configuration; we suggest: X8: monophase AC (P+N+E): 32 A rating, C or D curve, 10 kA; X8: triphase AC (3P+N+E): 4 x 16 A rating, C or D curve, 10 kA. X4: monophase AC (P+N+E): 16 A rating, C or D curve, 10 kA; X4: triphase AC (3P+N+E): 4 x 10 A rating, C or D curve, 10 kA. Before connecting this amplifier to the AC mains: f verify that your mains connection is capable of satisfying the power ratings of the device; f verify that a ground connection is available; f verify that a proper sectioning breaker is available; f connect all the five conductors to the flying plug as shown in the pictures. NOTE: The following pictures and instructions refer to the European CENELEC standards April 2004 (IEC 60446) color code for conductors iden- tification (ref. TABLE 1). X Series Quick guide DO000181 Three-phase electric power Usually, three-phase AC mains encompass four power conduc- tors plus ground (i.e. totally five conductors) in a so called 3P+N+E, three phase with neutral configuration. In some instances neutral connection may lack: on three-phase systems neutral connection is not even necessary given the capability of the X Series to work in delta connection. Each single conductor must be secured to the PC 5/5-STF1-7,62 flying plug as shown in FIGURE 1 . Bi-phase electric power X Series amplifier platforms can accept bi-phase AC mains in the configurations 2P+E (on bi-phase systems neutral connection is not even necessary). Take care to connect all of the five conduc- tors to the flying plug in order to guarantee the proper wire section. Power conductors must be secured to the PC 5/5-STF1-7,62 flying plug as shown in FIGURE 2. Bridge the phase conductors at the connecting terminals of the mains’ sectioning breaker. Single-phase electric power P+N+E, unbalanced single phase with neutral, is the usual con- figuration for signle-phase AC mains. Power conductors must be secured to the PC 5/5-STF1-7,62 flying plug as shown in FIGURE 3. Take care to connect all of the five conductors to the flying plug in order to guarantee the proper wire section. Bridge the phase and neutral conductors at the con- necting terminals of the mains’ sectioning breaker. Conductor Recommended wire section Neutral or mid-point conductor N 2,5 mm 2 13 AWG AC phase conductors L1 2,5 mm 2 13 AWG L2 2,5 mm 2 13 AWG L3 2,5 mm 2 13 AWG Protective conductor (earth) E 2,5 mm 2 13 AWG TABLE 2: Recommended wires gauge. Connect the earth wire first when making wire connection. Disconnect the earth wire last when making wire disconnection. Conductor Color Neutral or mid-point conductor N blue AC phase conductors L1 brown L2 black L3 grey Protective conductor (earth) E green/ yellow TABLE 1: Color code for conductors identification. FIGURE 1: Three-phase connection. FIGURE 2: Bi-phase connection. FIGURE 3: Single-phase connection.

Three-phase electric power X Series Quick guide AC mains ...shop.gowild.ch/shop/resources/downloads/X Series_quickmanual_E.… · Three-phase electric power Usually, three-phase AC

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Three-phase electric power X Series Quick guide AC mains ...shop.gowild.ch/shop/resources/downloads/X Series_quickmanual_E.… · Three-phase electric power Usually, three-phase AC

Keep this guide for future reference©2014 Powersoft| |

AC mains supplyThe following operations can be performed only by professional or qualified personnel

according to local electrical authorities guidelines.

Refer to the user manual for security and proper installation instructions

AC mains connection is provided by means of the euroblock Phoenix PC 5/5-STF1-7,62 connector and flying plug (Phoenix product ID 1777862). Proper assembly of the AC mains conductors to the flying plug must respect the power line configuration; recommended wires section is 2,5 mm2 / 13 AWG.This device must be powered exclusively by earth connected mains sockets in electrical networks compliant to the IEC 364 or similar rules.

Since the main power switch on this unit does not provide a complete insula-tion of the equipment from the mains power, you must disconnect the main power source to turn off all power. Provide a sectioning breaker between the mains connections and the amplifier. The correct device to use depends on mains configuration; we suggest:

X8: monophase AC (P+N+E): 32 A rating, C or D curve, 10 kA;X8: triphase AC (3P+N+E): 4 x 16 A rating, C or D curve, 10 kA.

X4: monophase AC (P+N+E): 16 A rating, C or D curve, 10 kA;X4: triphase AC (3P+N+E): 4 x 10 A rating, C or D curve, 10 kA.

Before connecting this amplifier to the AC mains:ff verify that your mains connection is capable of satisfying the power

ratings of the device;ff verify that a ground connection is available;ff verify that a proper sectioning breaker is available;ff connect all the five conductors to the flying plug as shown in the pictures.

NOTE: The following pictures and instructions refer to the European CENELEC standards April 2004 (IEC 60446) color code for conductors iden-tification (ref. TABLE 1).

X Series Quick guide

DO000181

Three-phase electric power

Usually, three-phase AC mains encompass four power conduc-tors plus ground (i.e. totally five conductors) in a so called 3P+N+E, three phase with neutral configuration. In some instances neutral connection may lack: on three-phase systems neutral connection is not even necessary given the capability of the X Series to work in delta connection. Each single conductor must be secured to the PC 5/5-STF1-7,62 flying plug as shown in FIGURE 1.

Bi-phase electric power

X Series amplifier platforms can accept bi-phase AC mains in the configurations 2P+E (on bi-phase systems neutral connection is not even necessary). Take care to connect all of the five conduc-tors to the flying plug in order to guarantee the proper wire section.

Power conductors must be secured to the PC 5/5-STF1-7,62 flying plug as shown in FIGURE 2. Bridge the phase conductors at the connecting terminals of the mains’ sectioning breaker.

Single-phase electric power

P+N+E, unbalanced single phase with neutral, is the usual con-figuration for signle-phase AC mains.

Power conductors must be secured to the PC 5/5-STF1-7,62 flying plug as shown in FIGURE 3. Take care to connect all of the five conductors to the flying plug in order to guarantee the proper wire section. Bridge the phase and neutral conductors at the con-necting terminals of the mains’ sectioning breaker.

Conductor Recommended wire section

Neutral or mid-point conductor N 2,5 mm2 13 AWG

AC phase conductors

L1 2,5 mm2 13 AWG

L2 2,5 mm2 13 AWG

L3 2,5 mm2 13 AWG

Protective conductor (earth) E 2,5 mm2 13 AWG

TABLE 2: Recommended wires gauge.

Connect the earth wire first when making wire connection. Disconnect the earth wire last when making wire disconnection.

Conductor Color

Neutral or mid-point conductor N blue

AC phase conductors

L1 brown

L2 black

L3 grey

Protective conductor (earth) E green/ yellow

TABLE 1: Color code for conductors identification.

FIGURE 1: Three-phase connection.

FIGURE 2: Bi-phase connection.

FIGURE 3: Single-phase connection.

Page 2: Three-phase electric power X Series Quick guide AC mains ...shop.gowild.ch/shop/resources/downloads/X Series_quickmanual_E.… · Three-phase electric power Usually, three-phase AC

General inquiries: [email protected]: [email protected] support: [email protected] & maintenance: [email protected]

Powersoft S.p.A.Via Enrico Conti, 550018 Scandicci (FI) ItalyTel: +39 055 735 0230Fax: +39 055 735 6235

WiFi remote connectionPowersoft X Series amplifier platforms provide a local WiFi network that allow the user to monitor the unit and make basic settings.

No dedicated application is needed for monitoring Powersoft X Series ampli-fier platform other than a supported web browser;ff Safari on iOS based devices;ff Chrome on Android and Windows based devices.

Follow this procedure to activate the WiFi connection and remotely access your Powersoft X Series amplifier platform.

1. Switch on the amplifier platform by holding down the central button on the front panel;

2. Press the leftmost button in the front panel: the button will light up and the system will establish a new local WiFi network whose SSID is in the form: Powersoft-MODELNAME-SERIAL (e.g. Powersoft-X8-70133)

6. Open the web browser and type the following IP address in the address bar:

192.168.0.1

7. The system will push the user interface to the browser: now you can start managing your X Series amplifier platform.

8. For simple recall and operation with the interface, we suggest to book-mark it: in iOS devices, when the interface has been completely loaded, click on the share icon and select “Add to Home Screen”.

3. Access your mobile device and edit the WiFi configuration:

4. Hang the WiFi network with the right SSID;

5. Insert the following WiFi encryption password: 0123456789

LED illuminated buttons

Switch ON: pressure on the Main on/off switch buttonSwitch OFF: long pressure (3 seconds) on the Main on/off switch buttonToggle MUTE/UNMUTE channel #: push on the channel # buttonToggle MUTE/UNMUTE all: short pressure on the Main on/off switch buttonToggle WiFi on/off: push on the WiFi on/off switch buttonIndentify the unit in Armonía Workspace: push on Armonía callback button

Center colorOUTPUT indicators

Ring colorINPUT indicators

color status color status

blue Channel ready white blinking

Input signal presence

orange MUTE red Input signal clipping

yellow User limiter engaged

color status

red blinking (center and ring) Channel fault

blinking / all channels (center and ring)

Unit answering toArmonía callback

PRIM

ARY

SECO

NDAR

Y

8

PRIM

ARY

SECO

NDAR

Y

8

WiFion/off switch

X8

X4

WiFion/off switch

Mainon/off switch

Mainon/off switch

Armoníacallback

Armoníacallback

USBport

USBport

CH1MUTE

CH5MUTE

CH2MUTE

CH6MUTE

CH3MUTE

CH3MUTE

CH1MUTE

CH7MUTE

CH4MUTE

CH4MUTE

CH2MUTE

CH8MUTE