Keep this guide for future reference©2014 Powersoft| |
AC mains supplyThe following operations can be performed only by professional or qualified personnel
according to local electrical authorities guidelines.
Refer to the user manual for security and proper installation instructions
AC mains connection is provided by means of the euroblock Phoenix PC 5/5-STF1-7,62 connector and flying plug (Phoenix product ID 1777862). Proper assembly of the AC mains conductors to the flying plug must respect the power line configuration; recommended wires section is 2,5 mm2 / 13 AWG.This device must be powered exclusively by earth connected mains sockets in electrical networks compliant to the IEC 364 or similar rules.
Since the main power switch on this unit does not provide a complete insula-tion of the equipment from the mains power, you must disconnect the main power source to turn off all power. Provide a sectioning breaker between the mains connections and the amplifier. The correct device to use depends on mains configuration; we suggest:
X8: monophase AC (P+N+E): 32 A rating, C or D curve, 10 kA;X8: triphase AC (3P+N+E): 4 x 16 A rating, C or D curve, 10 kA.
X4: monophase AC (P+N+E): 16 A rating, C or D curve, 10 kA;X4: triphase AC (3P+N+E): 4 x 10 A rating, C or D curve, 10 kA.
Before connecting this amplifier to the AC mains:ff verify that your mains connection is capable of satisfying the power
ratings of the device;ff verify that a ground connection is available;ff verify that a proper sectioning breaker is available;ff connect all the five conductors to the flying plug as shown in the pictures.
NOTE: The following pictures and instructions refer to the European CENELEC standards April 2004 (IEC 60446) color code for conductors iden-tification (ref. TABLE 1).
X Series Quick guide
DO000181
Three-phase electric power
Usually, three-phase AC mains encompass four power conduc-tors plus ground (i.e. totally five conductors) in a so called 3P+N+E, three phase with neutral configuration. In some instances neutral connection may lack: on three-phase systems neutral connection is not even necessary given the capability of the X Series to work in delta connection. Each single conductor must be secured to the PC 5/5-STF1-7,62 flying plug as shown in FIGURE 1.
Bi-phase electric power
X Series amplifier platforms can accept bi-phase AC mains in the configurations 2P+E (on bi-phase systems neutral connection is not even necessary). Take care to connect all of the five conduc-tors to the flying plug in order to guarantee the proper wire section.
Power conductors must be secured to the PC 5/5-STF1-7,62 flying plug as shown in FIGURE 2. Bridge the phase conductors at the connecting terminals of the mains’ sectioning breaker.
Single-phase electric power
P+N+E, unbalanced single phase with neutral, is the usual con-figuration for signle-phase AC mains.
Power conductors must be secured to the PC 5/5-STF1-7,62 flying plug as shown in FIGURE 3. Take care to connect all of the five conductors to the flying plug in order to guarantee the proper wire section. Bridge the phase and neutral conductors at the con-necting terminals of the mains’ sectioning breaker.
Conductor Recommended wire section
Neutral or mid-point conductor N 2,5 mm2 13 AWG
AC phase conductors
L1 2,5 mm2 13 AWG
L2 2,5 mm2 13 AWG
L3 2,5 mm2 13 AWG
Protective conductor (earth) E 2,5 mm2 13 AWG
TABLE 2: Recommended wires gauge.
Connect the earth wire first when making wire connection. Disconnect the earth wire last when making wire disconnection.
Conductor Color
Neutral or mid-point conductor N blue
AC phase conductors
L1 brown
L2 black
L3 grey
Protective conductor (earth) E green/ yellow
TABLE 1: Color code for conductors identification.
FIGURE 1: Three-phase connection.
FIGURE 2: Bi-phase connection.
FIGURE 3: Single-phase connection.
General inquiries: [email protected]: [email protected] support: [email protected] & maintenance: [email protected]
Powersoft S.p.A.Via Enrico Conti, 550018 Scandicci (FI) ItalyTel: +39 055 735 0230Fax: +39 055 735 6235
WiFi remote connectionPowersoft X Series amplifier platforms provide a local WiFi network that allow the user to monitor the unit and make basic settings.
No dedicated application is needed for monitoring Powersoft X Series ampli-fier platform other than a supported web browser;ff Safari on iOS based devices;ff Chrome on Android and Windows based devices.
Follow this procedure to activate the WiFi connection and remotely access your Powersoft X Series amplifier platform.
1. Switch on the amplifier platform by holding down the central button on the front panel;
2. Press the leftmost button in the front panel: the button will light up and the system will establish a new local WiFi network whose SSID is in the form: Powersoft-MODELNAME-SERIAL (e.g. Powersoft-X8-70133)
6. Open the web browser and type the following IP address in the address bar:
192.168.0.1
7. The system will push the user interface to the browser: now you can start managing your X Series amplifier platform.
8. For simple recall and operation with the interface, we suggest to book-mark it: in iOS devices, when the interface has been completely loaded, click on the share icon and select “Add to Home Screen”.
3. Access your mobile device and edit the WiFi configuration:
4. Hang the WiFi network with the right SSID;
5. Insert the following WiFi encryption password: 0123456789
LED illuminated buttons
Switch ON: pressure on the Main on/off switch buttonSwitch OFF: long pressure (3 seconds) on the Main on/off switch buttonToggle MUTE/UNMUTE channel #: push on the channel # buttonToggle MUTE/UNMUTE all: short pressure on the Main on/off switch buttonToggle WiFi on/off: push on the WiFi on/off switch buttonIndentify the unit in Armonía Workspace: push on Armonía callback button
Center colorOUTPUT indicators
Ring colorINPUT indicators
color status color status
blue Channel ready white blinking
Input signal presence
orange MUTE red Input signal clipping
yellow User limiter engaged
color status
red blinking (center and ring) Channel fault
blinking / all channels (center and ring)
Unit answering toArmonía callback
PRIM
ARY
SECO
NDAR
Y
8
PRIM
ARY
SECO
NDAR
Y
8
WiFion/off switch
X8
X4
WiFion/off switch
Mainon/off switch
Mainon/off switch
Armoníacallback
Armoníacallback
USBport
USBport
CH1MUTE
CH5MUTE
CH2MUTE
CH6MUTE
CH3MUTE
CH3MUTE
CH1MUTE
CH7MUTE
CH4MUTE
CH4MUTE
CH2MUTE
CH8MUTE