A R C H I T E C T U R A L D E T A I L F I L E 3-1 R E V . 0 3 / 0 5
T i l t - W a s h D o u b l e - H u n g W i n d o w s
Contents
Tilt-Wash Double-Hung Windows
Basic Unit Details - Tilt-Wash Double-Hung ....................................3-2
Basic Unit Details - Double-Hung Picture and Transom Window .......3-3
Options / Accessories
Andersen® Grilles .......................................................................3-4
Stools and Extension Jambs for Tilt-Wash Basic Units .................3-6
Stools and Extension Jambs for Double-Hung Picture Units ........3-7
Stools and Extension Jambs for Double-Hung Transom Units ......3-8
Combination Unit .......................................................................3-8
Joining Details ................................................................................3-9
Anchoring Methods .......................................................................3-12
Suggested Product Applications ....................................................3-13• Slim frame and sash profile maximize the field of view
• Excellent for creating window combinations
• Easy to clean.
• Low maintenance.
A R C H I T E C T U R A L D E T A I L F I L E3-2 R E V . 0 3 / 0 5
T i l t - W a s h D o u b l e - H u n g W i n d o w s
Vertical Section
Basic Unit Details - T ilt-Wash Double-Hung
Horizontal Section
Basic UnitScale 3" = 1'-0" (1:4)
Unit Dimension Width
Clear Opening Width
Rough Opening Width
1-7/8" (37)
1-7/8" (37)
1/4" (6) 1/4" (6)
1-5/16" (33)
4-1/2" (114)
3-5/16" (84)
3-5/16" (84)
JambJamb Lower sash
Upper sash
Optional Andersen®
insect screen
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
3-9/16" (91)
3/8" (10)
3/8" (10)
5/8" (16)
1/2" (13)
2-7/16" (62)
1-5/16"(33)
2-7/16" (62)
4-1/2" (114)1-5/16" (33)
1-1/2" (38)
1-1/2" (38)
Clea
r Ope
ning
Hei
ght
Optional Andersen® stool
High-Performance™insulating glass
Lower sash inopen position
Head
Check Rail
Sill
OptionalAndersen®
insect screen
Fibrex™ material sill
A R C H I T E C T U R A L D E T A I L F I L E 3-3 R E V . 0 3 / 0 5
T i l t - W a s h D o u b l e - H u n g W i n d o w s
Vertical Section
Basic Unit Details - Double-Hung Picture (DHP) and Transom (DHT) Window
Horizontal Section
Picture UnitScale 3" = 1'-0" (1:4)
Glass Width
Unit Dimension Width
Rough Opening Width
2-7/16" (62) 2-7/16" (62)
1/4" (6)1/4" (6)
1-5/16" (33)
4-1/2" (114)
1/2" (13)
2-7/16" (62)
2-7/16" (62)
5/8" (16)
1-1/2" (38)
1-5/16" (33)
3/8" (10)
4-1/2" (114)
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
Glas
s He
ight
3/8" (10)
Optional Andersen® stool
Fibrex™ material sill
Cladaluminum
1-5/16" (33)
1/4" (6)
1/4" (6)
4-1/2" (114)
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
Glas
s He
ight
2-15/16" (75)
2-3/8" (60)
Clad aluminum
1-5/16" (33)
4-1/2" (114)
Glass Width
Unit Dimension Width
Rough Opening Width
3-5/16" (84) 3-5/16" (84)
1/4" (6) 1/4" (6)
Vertical Section
Horizontal Section
Transom UnitScale 3" = 1'-0" (1:4)
A R C H I T E C T U R A L D E T A I L F I L E3-4 R E V . 0 3 / 0 5
T i l t - W a s h D o u b l e - H u n g W i n d o w s
Options / Accessories
Andersen® Divided Light Grilles
White
Sandtone
Terratone®
Forest Green
3/4"
7/8"
1-1/8"
2-1/4"
With Spacer
Without Spacer
Maple
Oak
Prefinished
Pine
Colonial
Modified Colonial
Modified Col W/Check Rail
Prairie A
Short Fractional
Short Fractional W/Check Rail
Tall Fractional
Tall Fractional W/Check Rail
Victorian
Renaissance
Sunburst
Specified Equal Light
Custom
HP/HP Tempered
HP Sun/HP Sun Temp
3/8" Low-E/Temp
Single-Pane Impact
Available now
Available only with 3/8" glass through the Andersen Divided Light program
Please check with Andersen for availability
Andersen®400 Series Windows
Gla
ss
Patt
erns
In
terio
r Ty
pe
Wid
th
Exte
rior C
olor
Andersen®400 Series Doors
Case
men
t & A
wnin
g
Case
men
t Pic
ture
Win
dow
Glid
ing
Win
dow
Woo
dwrig
ht®
Doub
le-H
ung
& Tr
anso
m
Woo
dwrig
ht®
Pict
ure
Win
dow
Woo
dwrig
ht®
Arch
top
& U
nequ
al L
eg A
rcht
op
Woo
dwrig
ht®
Sprin
glin
e™ S
ingl
e-Hu
ng
Tilt-
Was
h Do
uble
-Hun
g &
Tran
som
Tilt-
Was
h Pi
ctur
e W
indo
w
Circ
le To
p™ &
Qua
rter R
ound
Arch
Sprin
glin
e™
Flex
ifram
e®
Ellip
tical
Circ
le &
Ova
l
Goth
ic
200
Serie
s Na
rrolin
e® D
oubl
e-Hu
ng &
Tran
som
Fren
chwo
od®
Glid
ing
Fren
chwo
od®
Hing
ed In
swin
g
Fren
chwo
od®
Hing
ed O
utsw
ing
Fren
chwo
od®
Patio
Doo
r Sid
elig
hts &
Tran
som
s
A R C H I T E C T U R A L D E T A I L F I L E 3-5 R E V . 0 3 / 0 5
T i l t - W a s h D o u b l e - H u n g W i n d o w s
Andersen® Divided Light GrillePermanent ExteriorPermanent Interiorwith Spacer
Andersen® Divided Light GrillePermanent ExteriorPermanent Interior
Andersen® Divided Light GrillePermanent ExteriorRemovable Interior
RemovableInterior
Andersen® Finelight™Grilles-Between-the-Glass
3/32"
5/16"
5/16" 7/16"
7/16"
45˚
2-1/4"
53˚3/8"3/8"3/8" 53˚
7/8"
45˚45˚
3/4"
53˚ 35˚
1-1/8"
35˚
1/2"
1-13/16"
5/16" 7/16"
2-1/4"7/8"3/4" 1-1/8"
1/2"
7/8"3/4" 1-1/8"
1/2" 1-13/16"
5/16"5/16"5/16"
3/16"1/8" 5/16"
1/2"
1/8"
1/2" 1/2" 1/2" 1/2"
Permanent Exterior Fibrex® Material Grille Profiles (chamfer profile). Also used for pre-finished interior, except 400 Series Woodwright® double-hung windows.
Permanent Interior Wood Grille Profiles (chamfer profile).The Fibrex® material exterior grille is used when a permanent prefinished grille is specified, except with 400 Series Woodwright® double-hung windows.
Removable Interior Wood Grille Profile (roman ogee profile). Removable Interior Wood Grille Profile (Chamfer profile).400 Series Woodwright® double-hung windows only.
Permanent Full Divided Light Grille spacer location.
Andersen® Finelight™ Grilles-Between-the-Glass.
7/16"
7/8"3/4" 1-1/8"
3/8"
3/4"
1/2"
1"
Options / Accessories
Grille Profiles • Scale = Full • Dimensions include thickness of tape.
400 Series Grille Options
A R C H I T E C T U R A L D E T A I L F I L E3-6 R E V . 0 3 / 0 5
T i l t - W a s h D o u b l e - H u n g W i n d o w s
7-1/8" (181)Wall
6-9/16" (167)Wall
5-1/4" (133)Wall
23/32" (18)
2-1/32" (52)
2-19/32" (66)
1-27/32" (47)
3-27/32" (98)
For wall thicknesses up to 5-1/4" (133)
For wall thicknesses up to 7-1/8" (181)
Extension Jambs
Stools
11/16" (17)
7-1/8" (181)
6-9/16" (167)
5-1/4" (133)
4-9/16" (116)
7-1/8" (181)
6-9/16" (167)
5-1/4" (133)
4-9/16" (116)
2-15/16" (75)
23/32" (18)
Optionalfactory appliedDP upgrade sill stop
3/8" (10)
Sill
Jamb
Head
OptionalAndersen®stool
Options / Accessories
Stools and Extension Jambs for T ilt-Wash Basic UnitsScale 3" = 1'-0" (1:4)
Extension jambs available for 5-1/4" (133), 6-9/16" (167) or 7-1/8" (181) wall thickness. Stools are available for wall thicknesses up to 5-1/4" (133) or 7-1/8" (181) thick. Other wall dimensions can be accommodated with stool and extension jamb modification. Extension jambs are predrilled for easy application (except for 5-1/4" (133) sizes).
Vertical Section
A R C H I T E C T U R A L D E T A I L F I L E 3-7 R E V . 0 3 / 0 5
T i l t - W a s h D o u b l e - H u n g W i n d o w s
7-1/8" (181)Wall
6-9/16" (167)Wall
5-1/4" (133)Wall
23/32" (18)
2-1/32" (52)
2-19/32" (66)
1-27/32" (47)
3-27/32" (98)
For wall thicknesses up to 5-1/4" (133)
OptionalAndersen®stool
For wall thicknesses up to 7-1/8" (181)
Extension Jambs
Stools
11/16" (17)
7-1/8" (181)
6-9/16" (167)
5-1/4" (133)
4-9/16" (116)
23/32" (18)
2-15/16" (75)
7-1/8" (181)
6-9/16" (167)
5-1/4" (133)
4-9/16" (116)
3/8" (10)
Sill
Jamb
Head
Options / Accessories
Stools and Extension Jambs for Double-Hung Picture Units (DHP)Scale 3" = 1'-0" (1:4)
Vertical Section
Extension jambs available for 5-1/4" (133), 6-9/16" (167) or 7-1/8" (181) wall thickness. Stools are available for wall thicknesses up to 5-1/4" (133) or 7-1/8" (181) thick. Other wall dimensions can be accommodated with stool and extension jamb modification. Extension jambs are predrilled for easy application (except for 5-1/4" (133) sizes).
A R C H I T E C T U R A L D E T A I L F I L E3-8 R E V . 0 3 / 0 5
T i l t - W a s h D o u b l e - H u n g W i n d o w s
7-1/8" (181)Wall
6-9/16" (167)Wall
5-1/4" (133)Wall
23/32" (18)
2-1/32" (52)
2-19/32" (66)
1-27/32" (47)
3-27/32" (98)
For wall thicknesses up to 5-1/4" (133)
For wall thicknesses up to 7-1/8" (181)
Extension Jambs
Stools
11/16" (17)
7-1/8" (181)
6-9/16" (167)
5-1/4" (133)
4-9/16" (116)
23/32"(18)
7-1/8" (181)
6-9/16" (167)
5-1/4" (133)
4-9/16" (116)
3/8"(10)
Sill
Jamb
Head
OptionalAndersen®stool
4-1/2" (114)1-5/16" (33)
Hinge member
Combination unit for triple glazing
Stationaryupper storm panel
Insectscreen
Operatinglower panel
Head
Check Rail
Sill
OptionalAndersen®stool
Jamb
Combination unit
Options / Accessories
Stools and Extension Jambs for Double-Hung Transom Units (DHT) Scale 3" = 1'-0" (1:4)
Extension jambs available for 5-1/4" (133), 6-9/16" (167) or 7-1/8" (181) wall thickness. Stools are available for wall thicknesses up to 5-1/4" (133) or 7-1/8" (181) thick. Other wall dimensions can be accommodated with stool and extension jamb modification. Extension jambs are predrilled for easy application (except for 5-1/4" (133) sizes).
Vertical Section
Combination Unit Scale 3" = 1'-0" (1:4)
Vertical Section
At Head- Outer frame of combination unit fits into head jamb window unit. Hinges fastened to the exterior of the head jamb enables easy cleaning of the sill.At Check Rail - Strong aluminum check rail with stationary storm panel, insect screen and lower operating panel.At Jamb - Storm panel operates on smooth vinyl channels within the side stile frame members. Insect screen is located outside the storm panel.At Sill - Combination unit frame bottom rail with insect screen in place and operating lower panel in closed position.Complete unit furnished by Andersen, not applied to window unit.
Horizontal Section
A R C H I T E C T U R A L D E T A I L F I L E 3-9 R E V . 0 3 / 0 6
T i l t - W a s h D o u b l e - H u n g W i n d o w s
Tilt-Wash Double-Hung to Tilt-Wash Double-Hung Scale 3" = 1'-0" (1:4)
Non-Reinforced Mullion
Joining Details
Steel Reinforced Mullion
Support Mullion
Non-Reinforced Mullion
Steel Reinforced Mullion
Support Mullion
Double-Hung Picture to Double-Hung PictureScale 3" = 1'-0" (1:4)
Unit Dimension Width Unit Dimension Width
1/8" (3)(Ref.)
Optional Andersen®
exterior vinyltrim strip setin continuousbead of sealanteach side
Optional Andersen®
interior trim
2-7/8" (73)
Unit Dimension Width Unit Dimension Width
3/16" (5)
OptionalAndersen®
exterior vinyltrim strip setin continuousbead of sealanteach side
OptionalAndersen®
steelreinforced join
OptionalAndersen®
interior trim
2" (51)Unit Dimension Width Unit Dimension Width
Structuralsupportby others
OptionalAndersen®
2" supportmullionwood filler
OptionalAndersen® 2" support mullion trimstrip set in continuous bead of sealant eachside
Interior trimby others
Unit Dimension Width Unit Dimension Width
1/8" (3)(Ref.)
Optional Andersen®
exterior vinyltrim strip setin continuousbead of sealanteach side
Optional Andersen®
interior trim
2-7/8" (73)
Unit Dimension Width Unit Dimension Width
3/16" (5)
Optional Andersen®
steel reinforced join
Optional Andersen®
interior trim
Optional Andersen®
exterior vinyltrim strip setin continuousbead of sealanteach side
2" (51)Unit Dimension Width Unit Dimension Width
Structuralsupportby others
Interior trimby others
Optional Andersen®
2" supportmullionwood filler
Optional Andersen®
2" supporttrim strip set in continuousbead of sealant eachside
Joining Compatibility Many Andersen® units are designed to be joined with other Andersen units in a variety of non-reinforced and reinforced combinations. Other combination types and joining methods can be viewed in the Andersen® Product Guide for Professionals, in Andersen Window Studio® software, and by visiting www.andersenwindows.com. Combination designs should always be checked for design pressure performance requirements to ensure the appropriate joining method is specified.
A R C H I T E C T U R A L D E T A I L F I L E3-10 R E V . 0 3 / 0 5
T i l t - W a s h D o u b l e - H u n g W i n d o w s
Non-Reinforced Mullion
Steel Reinforced Mullion
Support Mullion
Double-Hung Transom to Double-Hung TransomScale 3" = 1'-0" (1:4)
Unit Dimension Width Unit Dimension Width
1/8" (3)(Ref.)
Optional Andersen®
exterior vinyltrim strip setin continuousbead of sealanteach side
Interior trimby others
2-7/8" (73)
Unit Dimension Width Unit Dimension Width
3/16" (5)
Optional Andersen®
steel reinforced join
Optional Andersen®
interior trim
Optional Andersen®
exterior vinyltrim strip setin continuousbead of sealanteach side
2" (51)Unit Dim. Unit Dim.
Structuralsupportby others
Interior trinby others
OptionalAndersen®
2" supportmullionwood filler
OptionalAndersen®
2" supportmulliontrim strip set in continuousbead of sealant eachside
Joining Details
Joining Compatibilty Many Andersen® units are designed to be joined with other Andersen units in a variety of non-reinforced and reinforced combinations. Other combination types and joining methods can be viewed in the Andersen® Product Guide for Professionals, in Andersen Window Studio® software, and by visiting www.andersenwindows.com. Combination designs should always be checked for design pressure performance requirements to ensure the appropriate joining method is specified.
A R C H I T E C T U R A L D E T A I L F I L E 3-11 R E V . 0 3 / 0 5
T i l t - W a s h D o u b l e - H u n g W i n d o w s
Joining Details
Double-Hung Transom (DHT) over T ilt-Wash Double-HungScale 3" = 1'-0" (1:4)
Vertical Section
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
Tilt-
Was
h Un
it Di
men
sion
+ D
oubl
e-Hu
ng Tr
anso
m U
nit D
imen
sion
= O
vera
ll Un
it Di
men
sion
4-1/2" (114)1-5/16" (33)
Unit
Dim
ensi
on H
eigh
t2-3/8" (60)
2-15/16" (75)
2-7/16" (62)
1/16" (2)
5/8" (16)
2-7/16" (62)
1/2" (13)
3-9/
16"
(91)
3/8" (10)
0"
3/8" (10)
1/8" (3)
Sill
Head
Transom
OptionalAndersen®trim
A R C H I T E C T U R A L D E T A I L F I L E3-12 R E V . 0 3 / 0 5
T i l t - W a s h D o u b l e - H u n g W i n d o w s
Standard application of installation flanges as shipped from Andersen to be used for 4-1/2" (105) wall construction. Tilt-wash double-hung window is secured in the opening by using threaded fasteners through the installation flange.
Anchoring Methods
Installation FlangeScale 3" = 1'-0" (1:4)
Standard Installation Flange ReversedScale 3" = 1'-0" (1:4)
Jamb ClipScale 3" = 1'-0" (1:4)
Regular installation flange in reverse position to accommodate a 4-1/8" (105) wall.
APPLICATION:
• First secure jamb clip to back side of window unit jamb(s)
• Apply 1' from corners of head jamb, sill and side jambs
• Space jamb clips evenly (maximum distance apart 32" on center)
• Jamb clip lateral design load capacity: maximum 200 lb.
4 1/2" (114)
3 1/2" (89)
1/2"(13)
1/2"(13)
Threaded Masonr y Fastener / Expansion SleeveScale 3" = 1'-0" (1:4)
Tilt-wash double-hung and double-hung transom (DHT) windows are secured in opening by removing the sash and jamb liners and drilling through the side jamb into the masonry. For double-hung picture (DHP) windows, remove the side jamb liner cover only.
4-1/8" (105)
Threaded fastener(furnished by others)
Jamb clip
Make sure that the unit frame parts do not become bowed when using anchoring methods. Unit will not operate properly if frame parts are stressed.
Double-hung window unit secured in opening by others using Andersen® 302 stainless steel sheet metal jamb clips and stainless steel screws. Bend the jamb clips to secure unit fit in opening. Installation flange can be cut, or removed, as required to accommodate the jamb clips.
Score markings for bending
3/16"(5)
1-1/2"(38)
3"(76)
A R C H I T E C T U R A L D E T A I L F I L E 3-13 R E V . 0 3 / 0 5
T i l t - W a s h D o u b l e - H u n g W i n d o w s
Wall Types
Suggested Product Applications
Scale 1-1/2" = 1'-0" (1:8)
Roug
h Op
enin
g He
ight
Unit
Dim
ensi
on H
eigh
t
Rgh.
Opg
.W
idth
1/4"(6)
Unit
Dim
.W
idth
Sill
Jamb
Head
Installationflangeall around
Installationflange all around
Head
Jamb
Sill
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
Rgh.
Opg
.W
idth
1/4"(6)
Unit
Dim
.W
idth
*1/2" (13) minimum to accommodate differential shrinkage/expansion when brick is used with wood framing.
1/2" (13)*minimum
Removeinstallationflangeat head
Vertical SectionBrick Veneer / 2 x 6 Metal Stud Framing
Vertical SectionWood Siding / 2 x 4 Wood Stud Framing
Vertical SectionE.I.F.S. / Concrete Masonr y Unit (CMU)
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
Rgh.
Opg
.W
idth
Unit
Dim
.W
i dth
1/4"(6)
Installationflange allaround
Head
Jamb
Sill
Membrane flashing over installationflange(by others)
Importance of Proper InstallationProper installation and maintenance of Andersen® products are essential if optimum performance is to be fully attained. Written installation instructions which provide guidelines for proper installation are available for Andersen products from your local Andersen supplier or by writing to: Andersen Windows, Inc., Box 12, Bayport, MN 55003 or by visiting our website at www.andersenwindows.com. Remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor, architect, or structural engineer prior to the installation of any Andersen product. Installation of Andersen products, including method of attachment, fastener selection, and code compliance is the sole responsibility of the architect, building owner, contractor, and/or consumer.
Construction by OthersAndersen Corporation is not responsible for the design of, conditions in, or performance of, adjacent wall or roof construction beyond the perimeter of the Andersen units. Proper integration of the Andersen units with the weather-repellent system of the building is the responsibility of others.
NOTE: Where E.I.F.S. wall finish is adjacent to window units, contact E.I.F.S. manufacturer for installation instructions, including the use of appropriate flashing, the proper use of sealant and backer rod, and the
proper width of sealant joint around the perimeter of the window.
NOTE: Leave adequate clearance between sill and masonry for caulking and dimensional change of framework. Installation flange may be removed where construction sequence/ detailing requires no flange.
A R C H I T E C T U R A L D E T A I L F I L E3-14 R E V . 0 3 / 0 5
T i l t - W a s h D o u b l e - H u n g W i n d o w s
Vertical SectionBrick / Concrete Masonr y Unit (CMU)
Vertical SectionStucco / Concrete Masonr y Unit
(CMU) Inset Window
Vertical SectionExisting Stud Wall
Vertical SectionExisting Masonr y Wall
Roug
h Op
enin
g He
ight
Unit
Dim
ensi
on H
eigh
t
1/4" (6)
Unit
Dim
.W
idth
Rgh.
Opg
.W
idth
Jamb
Head
Sill
Optional Andersen®
auxiliarycasing
Installationflangeall around
Wall Types
Suggested Product Applications
Head
Jamb
Optional Andersen®
auxiliarycasing
Sill
Unit
Dim
ensi
on H
eigh
t
Installationflange at headand jambs
Roug
h Op
enin
g He
ight
Removeinstallationflangeat sill
1/4"(6)
Unit
Dim
.W
idth
Rgh.
Opg
.W
idth
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
Rgh.
Opg
.W
idth
1/4"(6)
Unit
Dim
.W
idth
Optional Andersen®
vinyl trim board
Existingframe wall
Installationflangeall around
Head
Jamb
Sill
Roug
h Op
enin
g He
ight
Unit
Dim
ensi
on H
eigh
t
1/4"(6)
Unit
Dim
.W
idth
Rgh.
Opg
.W
idth
Existing masonry wall
Installationflange all around
Jamb
Head
Sill
Optional Andersen®
vinyl trimboard.Trim to fitas required.Finish trimmededge with Optional Andersenrigid vinylchannel
OptionalAndersenextension jambs
Importance of Proper InstallationProper installation and maintenance of Andersen® products are essential if optimum performance is to be fully attained. Written installation instructions which provide guidelines for proper installation are available for Andersen products from your local Andersen supplier or by writing to: Andersen Windows, Inc., Box 12, Bayport, MN 55003 or by visiting our website at www.andersenwindows.com. Remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor, architect, or structural engineer prior to the installation of any Andersen product. Installation of Andersen products, including method of attachment, fastener selection, and code compliance is the sole responsibility of the architect, building owner, contractor, and/or consumer.
Construction by OthersAndersen Corporation is not responsible for the design of, conditions in, or performance of, adjacent wall or roof construction beyond the perimeter of the Andersen units. Proper integration of the Andersen units with the weather-repellent system of the building is the responsibility of others.
NOTE: Where E.I.F.S. wall finish is adjacent to window units, contact E.I.F.S. manufacturer for installation instructions, including the use of appropriate flashing, the proper use of sealant and backer rod, and the
proper width of sealant joint around the perimeter of the window.
NOTE: Leave adequate clearance between sill and masonry for caulking and dimensional change of framework. Installation flange may be removed where construction sequence/ detailing requires no flange.