4
Toyota Supports ASE Certification Page 1 of 4 EL007–00 Title: HEATER CONTROL ASSEMBLY INSTRUCTIONS Models: ’97 – ’99 Camry Technical Service BULLETIN April 14, 2000 The attached instructions have been developed to supplement the Repair Manual to assure corrrect cable routing of the heater control assembly during a service repair. PUBLICATION NUMBER 1997 Camry Repair Manual, Vol. 2 RM503U2 1998 Camry Repair Manual, Vol. 2 RM589U2 1999 Camry Repair Manual, Vol. 2 RM654U2 NOTE: For maximum heater performance the coolant ratio should be 50 to 60 percent. S 1997 – 1999 model year Camry OP CODE DESCRIPTION TIME OPN T1 T2 N/A Not Applicable to Warranty ELECTRICAL Introduction Applicable Vehicles Warranty Information

Title: HEATER CONTROL ASSEMBLY EL007–00 Technical Service

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Title: HEATER CONTROL ASSEMBLY EL007–00 Technical Service

Toyota Supports ASE Certification Page 1 of 4

EL007–00

Title:

HEATER CONTROL ASSEMBLY

INSTRUCTIONSModels:

’97 – ’99 Camry

Technical ServiceBULLETIN

April 14, 2000

The attached instructions have been developed to supplement the Repair Manual toassure corrrect cable routing of the heater control assembly during a service repair.

PUBLICATION NUMBER

1997 Camry Repair Manual, Vol. 2 RM503U2

1998 Camry Repair Manual, Vol. 2 RM589U2

1999 Camry Repair Manual, Vol. 2 RM654U2

NOTE:For maximum heater performance the coolant ratio should be 50 to 60 percent.

� 1997 – 1999 model year Camry

OP CODE DESCRIPTION TIME OPN T1 T2

N/A Not Applicable to Warranty – – – –

ELE

CT

RIC

AL

Introduction

ApplicableVehicles

WarrantyInformation

Page 2: Title: HEATER CONTROL ASSEMBLY EL007–00 Technical Service

POOR HEATER PERFORMANCE – EL007–00 April 14, 2000

Page 2 of 4

A. Pull out the inner cable of theREC/FRE cable until the link of theA/C unit contacts the link stopper.

View A

TopLeft Side

Rear

View A

Link

Should makecontact here.

Link Stopper

B. Set the air intake selector of theheater control unit all the way to the“FRESH” position.

C. Attach the REC/FRE cable to theheater control unit lever pin and clampthe outer cable to the secure clamp.

NOTE:Clamp the cable while pushing theouter cable to the A/C unit assemblyside.

InstallationProcedure

Lever

Page 3: Title: HEATER CONTROL ASSEMBLY EL007–00 Technical Service

POOR HEATER PERFORMANCE – EL007–00 April 14, 2000

Page 3 of 4

D. Install the heater control panel to theinstrument panel with 4 screws.

NOTE:Make sure air mix cable is routedoutside of the brace.

REC/FRE Cable(from A/C Unit)

Step (C)

Instrument Panel

Step (A)

Step (D)

Air Mix Cable

Screw (4)Right Side

Front Side

Top

InstallationProcedure(Continued)

Page 4: Title: HEATER CONTROL ASSEMBLY EL007–00 Technical Service

POOR HEATER PERFORMANCE – EL007–00 April 14, 2000

Page 4 of 4

E. Set the temperature selector of theheater control unit to the “MAX.COOL” position.

F. Connect the air mix cable connectorto the air mix link pin on the left sideof the A/C unit and clamp the outercable to the secure clamp.

NOTE:� It is unnecessary to push or pull the

outer cable.� Do not bend the cable when setting

the cable.� Do not move the air mix knob until

you are finished clamping the outercable.

1. Rotary Knob For TemperatureControl

Operate the temperature controlrotary knob after setting the cables,check that there is a “thump” at theend of the travel, and no reversingforce at “MAX. COOL” or “MAX. HOT”position.

2. Air Inlet Lever

Operate air inlet lever after setting thecable and check that there is a “click”at the end of the travel and noreversing force at “RECIRCULATE”and “FRESH” positions.

3. Blower Switch, Air Flow ModeSwitch & A/C Switch

Operate each switch and make surethey are operating correctly.

InstallationProcedure(Continued)

MAX.COOL

AirMixLink

InspectionProcedure