Toyota Supports ASE Certification Page 1 of 4
EL007–00
Title:
HEATER CONTROL ASSEMBLY
INSTRUCTIONSModels:
’97 – ’99 Camry
Technical ServiceBULLETIN
April 14, 2000
The attached instructions have been developed to supplement the Repair Manual toassure corrrect cable routing of the heater control assembly during a service repair.
PUBLICATION NUMBER
1997 Camry Repair Manual, Vol. 2 RM503U2
1998 Camry Repair Manual, Vol. 2 RM589U2
1999 Camry Repair Manual, Vol. 2 RM654U2
NOTE:For maximum heater performance the coolant ratio should be 50 to 60 percent.
� 1997 – 1999 model year Camry
OP CODE DESCRIPTION TIME OPN T1 T2
N/A Not Applicable to Warranty – – – –
ELE
CT
RIC
AL
Introduction
ApplicableVehicles
WarrantyInformation
POOR HEATER PERFORMANCE – EL007–00 April 14, 2000
Page 2 of 4
A. Pull out the inner cable of theREC/FRE cable until the link of theA/C unit contacts the link stopper.
View A
TopLeft Side
Rear
View A
Link
Should makecontact here.
Link Stopper
B. Set the air intake selector of theheater control unit all the way to the“FRESH” position.
C. Attach the REC/FRE cable to theheater control unit lever pin and clampthe outer cable to the secure clamp.
NOTE:Clamp the cable while pushing theouter cable to the A/C unit assemblyside.
InstallationProcedure
Lever
POOR HEATER PERFORMANCE – EL007–00 April 14, 2000
Page 3 of 4
D. Install the heater control panel to theinstrument panel with 4 screws.
NOTE:Make sure air mix cable is routedoutside of the brace.
REC/FRE Cable(from A/C Unit)
Step (C)
Instrument Panel
Step (A)
Step (D)
Air Mix Cable
Screw (4)Right Side
Front Side
Top
InstallationProcedure(Continued)
POOR HEATER PERFORMANCE – EL007–00 April 14, 2000
Page 4 of 4
E. Set the temperature selector of theheater control unit to the “MAX.COOL” position.
F. Connect the air mix cable connectorto the air mix link pin on the left sideof the A/C unit and clamp the outercable to the secure clamp.
NOTE:� It is unnecessary to push or pull the
outer cable.� Do not bend the cable when setting
the cable.� Do not move the air mix knob until
you are finished clamping the outercable.
1. Rotary Knob For TemperatureControl
Operate the temperature controlrotary knob after setting the cables,check that there is a “thump” at theend of the travel, and no reversingforce at “MAX. COOL” or “MAX. HOT”position.
2. Air Inlet Lever
Operate air inlet lever after setting thecable and check that there is a “click”at the end of the travel and noreversing force at “RECIRCULATE”and “FRESH” positions.
3. Blower Switch, Air Flow ModeSwitch & A/C Switch
Operate each switch and make surethey are operating correctly.
InstallationProcedure(Continued)
MAX.COOL
AirMixLink
InspectionProcedure