8
TOOLS FOR THE SPECIALIST AXIAL FANS/ AIR MOVERS “SPITZJET“

TOOLS FOR THE SPECIALIST AXIAL FANS/ AIR MOVERS “SPITZJET · 2018. 8. 14. · Length Air consumption Maximum operating pressure 8 1532 0300 400 420 4 2.03 32.0 bar m³/min kg Noise

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: TOOLS FOR THE SPECIALIST AXIAL FANS/ AIR MOVERS “SPITZJET · 2018. 8. 14. · Length Air consumption Maximum operating pressure 8 1532 0300 400 420 4 2.03 32.0 bar m³/min kg Noise

TOOLS FOR THE SPECIALISTAXIAL FANS/AIR MOVERS “SPITZJET“

Page 2: TOOLS FOR THE SPECIALIST AXIAL FANS/ AIR MOVERS “SPITZJET · 2018. 8. 14. · Length Air consumption Maximum operating pressure 8 1532 0300 400 420 4 2.03 32.0 bar m³/min kg Noise

AXIAL FAN FEATURES

Pneumatic or electric type

Load-bearing eye

MOBILE TYPE

For suction and blowing Protective grill

Air supply with shutoff deviceFan wheel (grill on request)

STATIONARYTYPE

Page 3: TOOLS FOR THE SPECIALIST AXIAL FANS/ AIR MOVERS “SPITZJET · 2018. 8. 14. · Length Air consumption Maximum operating pressure 8 1532 0300 400 420 4 2.03 32.0 bar m³/min kg Noise

(Sub

ject

to c

hang

e w

ithou

t not

ice)

Gewicht

Nominaldiameter

Length Airconsumption

Max. operating pressure

TECHNICAL SPECIFICATION

8 1611 03008 1613 0300*

300300

350380

55

0.450.45

13.014.5

bar m³/min kg

Noiselevel

85.785.7

dB(A)II2GcIIBT6II2GcIIBT6

ATEXGuideline

2014/34/EU

Performance data at an operating pressure of 4 (5) bar (cont. flow).

Weight

Order no.

AXIAL FAN nominal diameter 300 mmMobile axial fan with 300 mm nominal diameter for various ventilation work.

Earthing required.

(*with seperate exhaust connection on housing)

mm mm

Volume flow(unrestricted)

0.570.57

m³/s

GewichtNominaldiameter

Length Airconsumption

Max. operating pressure

8 1601 03008 1602 03008 1603 0300*

300300300

350350370

555

0.581.160.58

13.013.014.0

bar m³/min kg

Noiselevel

878585

dB(A)

Weight

Order no.

AXIAL FAN nominal diameter 300 mmMobile axial fan with 300 mm nominal diameter for various ventilation work.Earthing required.

(*with seperate exhaust connection on housing)

mm mm

Volume flow(unrestricted)

0.781.000.78

m³/s

GewichtNominaldiameter

Length Airconsumption

Max. operating pressure

8 1501 0300 300 410 4 1.28 22.0bar m³/min kg

Noiselevel

101dB(A)

Weight

Order no.

AXIAL FAN nominal diameter 300 mmStationary axial fan with 300 mm nominal diameter for various ventilation work.

Earthing required.

mm mm

Volume flow(unrestricted)

1.53m³/s

GewichtNominaldiameter

Length Airconsumption

Max. operating pressure

bar m³/min kg

Noiselevel

dB(A)

Weight

Order no.

AXIAL FAN nominal diameter 300 mmStationary axial fan with 300 mm nominal diameter for various ventilation work. Suitable for e. g. tank aeration, cleaning work and many other applications in explosive areas.

Earthing required.

mm mm

Volume flow(unrestricted)

m³/s

8 1531 0300 300 410 4 2.02 21.01.57II2GcIIBT6

ATEXGuideline

2014/34/EU

99.0

Page 4: TOOLS FOR THE SPECIALIST AXIAL FANS/ AIR MOVERS “SPITZJET · 2018. 8. 14. · Length Air consumption Maximum operating pressure 8 1532 0300 400 420 4 2.03 32.0 bar m³/min kg Noise

GewichtNominaldiameter

Nominalspeed

Nominalvoltage

Motoroutput

TECHNICAL SPECIFICATION

8 1020 01408 1020 08408 1020 08508 1020 0860*8 1020 0870

300300300300300

2,8402,9002,900

2,900/3,4802,870

0.350.370.370.370.37

230/400110110110230

20.020.520.520.520.5

kW V kg

Noiselevel

86.085.085.085.085.0

dB(A)II2GcIIBT3II2GcIIBT3II2GcIIBT3II2GcIIBT3II2GcIIBT3

ATEXGuideline

2014/34/EU

Performance data at an operating pressure of 4 bar (cont. flow).

Weight

Order no.

AXIAL FAN nominal diameter 300 mmElectric fan, especially for explosive areas with 300 mm nominal diameter and protection class IP55.

Earthing required.

mm rpm

Volumeflow(unrestricted)

1.01.01.01.01.0

m³/s

Current consumptionat nom. voltage

1.6/0.925.15.15.12.3

A

Alternatingcurrentsingle-phase

5050

50/6050

Hz

Alternatingcurrentthree-phase

50Hz

GewichtNominaldiameter

Length Airconsumption

Maximumoperatingpressure

8 1502 0300 400 420 4 2.11 32.0bar m³/min kg

Noise level

92dB(A)

Weight

Order no.

AXIAL FAN nominal diameter 400 mmBuilt-in fan with 400 mm nominal diameter and increased conveying volume.

Earthing required.

mm mm

Volume flow(unrestricted)

2.70m³/s

GewichtNominaldiameter

Length Airconsumption

Maximumoperatingpressure

8 1532 0300 400 420 4 2.03 32.0bar m³/min kg

Noise level

106dB(A)

Weight

Order no.

AXIAL FAN nominal diameter 400 mmBuilt-in fan with 400 mm nominal diameter and increased conveying volume for use in explosive areas.

Earthing required.

mm mm

Volume flow(unrestricted)

3.15m³/s

Performance data at nominal voltage.

(Sub

ject

to c

hang

e w

ithou

t not

ice)

ATEXGuideline

2014/34/EU

II2GcIIBT6

* incl. ON/OFF switch

Page 5: TOOLS FOR THE SPECIALIST AXIAL FANS/ AIR MOVERS “SPITZJET · 2018. 8. 14. · Length Air consumption Maximum operating pressure 8 1532 0300 400 420 4 2.03 32.0 bar m³/min kg Noise

GewichtNominaldiameter

Length Airconsumption

Maximumoperatingpressure

bar m³/min kg

Noiselevel

dB(A)

Weight

Order no.

AXIAL FAN nominal diameter 500 mm

mm mm

Volume flow(unrestricted)

m³/s

ATEXGuideline

2014/34/EU

8 1533 0300 500 520 4 2.73 46.01054.33II2GcIIBT6

TECHNICAL SPECIFICATIONPerformance data at an operating pressure of 4 bar (cont. flow).

GewichtNominaldiameter

Length Airconsumption

Maximumoperatingpressure

8 1504 0300 600 520 4 3.84 58.0bar m³/min kg

Noiselevel

86dB(A)

Weight

Order no.

AXIAL FAN nominal diameter 600 mmOur most powerful fan with a volume flow of more than 5 m³/s.

Earthing required.

mm mm

Volume flow(unrestricted)

5.83m³/s

GewichtNominaldiameter

Length Airconsumption

Maximumoperatingpressure

bar m³/min kg

Noiselevel

dB(A)

Weight

Order no.

AXIAL FAN nominal diameter 600 mmOur most powerful fan with a volume flow of more than 5 m³/s for use in explosive areas.

Earthing required.

mm mm

Volume flow(unrestricted)

m³/s

ATEXGuideline

2014/34/EU

8 1534 0300 600 520 4 3.84 58.0995.83II2GcIIBT6 (Sub

ject

to c

hang

e w

ithou

t not

ice)

GewichtNominaldiameter

Length Airconsumption

Maximumoperatingpressure

8 1503 0300 500 520 4 2.73 46.0bar m³/min kg

Noise level

90dB(A)

Weight

Order no.

AXIAL FAN nominal diameter 500 mm

mm mm

Volume flow(unrestricted)

4.33m³/s

Built-in fan with increased conveying volume and a volume flow of more than 4 m³/s for use in explosive areas.

Earthing required.

Built-in fan with increased conveying volume and a volume flow of more than 4 m³/s.

Earthing required.

Page 6: TOOLS FOR THE SPECIALIST AXIAL FANS/ AIR MOVERS “SPITZJET · 2018. 8. 14. · Length Air consumption Maximum operating pressure 8 1532 0300 400 420 4 2.03 32.0 bar m³/min kg Noise

AIR MOVER FEATURES „SPITZJET“

Handle with on/off valve

For ventilation and exhaust

Handle for mobile use

Suction side with venturi nozzle

Earthing cable connectionExhaust side

Air Flow

Air Flow

Page 7: TOOLS FOR THE SPECIALIST AXIAL FANS/ AIR MOVERS “SPITZJET · 2018. 8. 14. · Length Air consumption Maximum operating pressure 8 1532 0300 400 420 4 2.03 32.0 bar m³/min kg Noise

GewichtNominaldiameter(outer)

Length Volume flow (unrestricted)

TECHNICAL SPECIFICATION

m³/min kg

Noise level(unrestricted)

dB(A)

ATEXGuideline

2014/34/EU

Performance data at an operating pressure of 4-6 bar (cont. flow).

Weight

Order no.

AIR MOVER „SPITZJET“Due to the venturi principle, these robust fans are maintenance-free and free of wear and tear. The practical handle ensures mobile work at universal applications.

Earthing required.

mm mm

Airconsumption

m³/min

6 bar 5 bar 4 bar

m³/min m³/min

Connection

(Sub

ject

to c

hang

e w

ithou

t not

ice)

Additional accessories on request.

8 1614 00108 1616 00108 1618 00108 1620 00108 1622 00108 1624 0010

100125150180200250

410425435450450450

20.526.249.867.578.388.7

3.33.95.25.36.88.0

100.8101.1103.8104.4115.8116.3

II2GcT6II2GcT6II2GcT6II2GcT6II2GcT6II2GcT6

1.6 up to 2.31.7 up to 2.42.8 up to 4.42.9 up to 4.56.3 up to 9.76.4 up to 9.5

17.723.342.762.065.378.9

14.919.636.353.654.367.2

G 3/8“female

G 3/8“female

G 1/2“female

G 1/2“female

G 3/4“female

G 3/4“female

Nominaldiameter(outer)

Length Volume flow (unrestricted)

m³/min kg

Noise level(unrestricted)

dB(A)

ATEXGuideline

2014/34/EU

Weight

Order no.

AIR MOVER „SPITZJET“Due to the venturi principle, these robust stainless steel fans are maintenance-free and free of wear and tear. The practical handle ensures mobile work at universal applications.

Earthing required.

mm mm

Airconsumption

m³/min

6 bar 5 bar 4 bar

m³/min m³/min

Connection

8 1634 00108 1636 00108 1638 00108 1640 00108 1642 00108 1644 0010

101.6129.0154.0168.3204.0219.1

410425435450450450

21.627.452.559.081.583.5

4.85.67.57.79.911.5

100.8101.1103.8104.4115.8116.3

IM2cT6IM2cT6IM2cT6IM2cT6IM2cT6IM2cT6

1.6 up to 2.31.7 up to 2.42.8 up to 4.42.9 up to 4.56.3 up to 9.76.4 up to 9.5

18.221.747.054.268.072.1

15.318.638.346.856.560.8

G 1/2“female

G 1/2“female

G 1/2“female

G 1/2“female

G 3/4“female

G 3/4“female

Page 8: TOOLS FOR THE SPECIALIST AXIAL FANS/ AIR MOVERS “SPITZJET · 2018. 8. 14. · Length Air consumption Maximum operating pressure 8 1532 0300 400 420 4 2.03 32.0 bar m³/min kg Noise

300 mm9 3709 0260Connecting piece

for fans with nominal diameterDescription 400 mm

9 3709 0270500 mm

9 3709 0280600 mm

9 3709 0290

ACCESSORIES

The connecting piece is an intersection from hose to fan. It can be installed at the suction side and at the discharge side.

CONNECTING PIECE, ANTISTATC

300 mm9 3709 0300Quick-seal coupling

for fans with nominal diameterDescription 400 mm

9 3709 0310500 mm

9 3709 0320600 mm

9 3709 0330

The quick-seal coupling joins the connection and the hose.QUICK-SEAL COUPLING, ANTISTATIC

300 mm9 3709 0220Air duct

for fans with nominal diameterDescription 400 mm

9 3709 0230500 mm

9 3709 0240600 mm

9 3709 0250

The air duct is flexible and adapts itself perfectly to any shape.It can be extended variably by using the quick-seal coupling.

AIR DUCT, ANTISTATIC, 5 m

Select according to nominal diameter (*incl. assembling screws).

300 mm

PROTECTIVE GRILL

8 1501 70108 1501 9010*8 1601 20708 1020 2070

Typ 8 1501 - 8 1534Typ 8 1501 - 8 1534Typ 8 1020, 8 1601-03, 8 1611-13Typ 8 1020 0840, 8 1020 0860

for fans with nominal diameterUsed for 400 mm

8 1502 70108 1502 9010*

500 mm8 1503 70108 1503 9010*

600 mm8 1504 70108 1504 9010*

Required if flanged pipes are to be fitted on suction and/or discharge side. Select according to nominal diameter of fan.

300 mm

FLANGE ACCORDING TO DIN 21603

9 3001 0010According to DIN 21603

for fans with nominal diameterDescription 400 mm

9 3001 0020500 mm

9 3001 0030600 mm

9 3001 0040

The reducing piece adapts the hose diameter to various location situations.ADAPTER

Adapter from diameter 300 mm to diameter 200 mmAdapter from diameter 300 mm to diamater 80 mmAdapter from diameter 300 mm to diameter 100 mmAdapter from diameter 300 mm to diameter 150 mm

Description9 3703 00509 3703 02809 3703 02909 3703 0300

Order no.

Additional accessories on request.

Imperatively required for all axial fans and air movers.Can be used for all fans and SPITZJETS. The total length with clamp is 1.5 m.

EARTHING CABLE

Earthing cable completeDescription

9 3707 0020Order no.

For safety reasons an additional grill should be fitted when used without ducting.1.

3.

2.Pos.

1223

05/1