Upload
others
View
0
Download
0
Embed Size (px)
Citation preview
TOOLS FOR THE SPECIALISTAXIAL FANS/AIR MOVERS “SPITZJET“
AXIAL FAN FEATURES
Pneumatic or electric type
Load-bearing eye
MOBILE TYPE
For suction and blowing Protective grill
Air supply with shutoff deviceFan wheel (grill on request)
STATIONARYTYPE
(Sub
ject
to c
hang
e w
ithou
t not
ice)
Gewicht
Nominaldiameter
Length Airconsumption
Max. operating pressure
TECHNICAL SPECIFICATION
8 1611 03008 1613 0300*
300300
350380
55
0.450.45
13.014.5
bar m³/min kg
Noiselevel
85.785.7
dB(A)II2GcIIBT6II2GcIIBT6
ATEXGuideline
2014/34/EU
Performance data at an operating pressure of 4 (5) bar (cont. flow).
Weight
Order no.
AXIAL FAN nominal diameter 300 mmMobile axial fan with 300 mm nominal diameter for various ventilation work.
Earthing required.
(*with seperate exhaust connection on housing)
mm mm
Volume flow(unrestricted)
0.570.57
m³/s
GewichtNominaldiameter
Length Airconsumption
Max. operating pressure
8 1601 03008 1602 03008 1603 0300*
300300300
350350370
555
0.581.160.58
13.013.014.0
bar m³/min kg
Noiselevel
878585
dB(A)
Weight
Order no.
AXIAL FAN nominal diameter 300 mmMobile axial fan with 300 mm nominal diameter for various ventilation work.Earthing required.
(*with seperate exhaust connection on housing)
mm mm
Volume flow(unrestricted)
0.781.000.78
m³/s
GewichtNominaldiameter
Length Airconsumption
Max. operating pressure
8 1501 0300 300 410 4 1.28 22.0bar m³/min kg
Noiselevel
101dB(A)
Weight
Order no.
AXIAL FAN nominal diameter 300 mmStationary axial fan with 300 mm nominal diameter for various ventilation work.
Earthing required.
mm mm
Volume flow(unrestricted)
1.53m³/s
GewichtNominaldiameter
Length Airconsumption
Max. operating pressure
bar m³/min kg
Noiselevel
dB(A)
Weight
Order no.
AXIAL FAN nominal diameter 300 mmStationary axial fan with 300 mm nominal diameter for various ventilation work. Suitable for e. g. tank aeration, cleaning work and many other applications in explosive areas.
Earthing required.
mm mm
Volume flow(unrestricted)
m³/s
8 1531 0300 300 410 4 2.02 21.01.57II2GcIIBT6
ATEXGuideline
2014/34/EU
99.0
GewichtNominaldiameter
Nominalspeed
Nominalvoltage
Motoroutput
TECHNICAL SPECIFICATION
8 1020 01408 1020 08408 1020 08508 1020 0860*8 1020 0870
300300300300300
2,8402,9002,900
2,900/3,4802,870
0.350.370.370.370.37
230/400110110110230
20.020.520.520.520.5
kW V kg
Noiselevel
86.085.085.085.085.0
dB(A)II2GcIIBT3II2GcIIBT3II2GcIIBT3II2GcIIBT3II2GcIIBT3
ATEXGuideline
2014/34/EU
Performance data at an operating pressure of 4 bar (cont. flow).
Weight
Order no.
AXIAL FAN nominal diameter 300 mmElectric fan, especially for explosive areas with 300 mm nominal diameter and protection class IP55.
Earthing required.
mm rpm
Volumeflow(unrestricted)
1.01.01.01.01.0
m³/s
Current consumptionat nom. voltage
1.6/0.925.15.15.12.3
A
Alternatingcurrentsingle-phase
5050
50/6050
Hz
Alternatingcurrentthree-phase
50Hz
GewichtNominaldiameter
Length Airconsumption
Maximumoperatingpressure
8 1502 0300 400 420 4 2.11 32.0bar m³/min kg
Noise level
92dB(A)
Weight
Order no.
AXIAL FAN nominal diameter 400 mmBuilt-in fan with 400 mm nominal diameter and increased conveying volume.
Earthing required.
mm mm
Volume flow(unrestricted)
2.70m³/s
GewichtNominaldiameter
Length Airconsumption
Maximumoperatingpressure
8 1532 0300 400 420 4 2.03 32.0bar m³/min kg
Noise level
106dB(A)
Weight
Order no.
AXIAL FAN nominal diameter 400 mmBuilt-in fan with 400 mm nominal diameter and increased conveying volume for use in explosive areas.
Earthing required.
mm mm
Volume flow(unrestricted)
3.15m³/s
Performance data at nominal voltage.
(Sub
ject
to c
hang
e w
ithou
t not
ice)
ATEXGuideline
2014/34/EU
II2GcIIBT6
* incl. ON/OFF switch
GewichtNominaldiameter
Length Airconsumption
Maximumoperatingpressure
bar m³/min kg
Noiselevel
dB(A)
Weight
Order no.
AXIAL FAN nominal diameter 500 mm
mm mm
Volume flow(unrestricted)
m³/s
ATEXGuideline
2014/34/EU
8 1533 0300 500 520 4 2.73 46.01054.33II2GcIIBT6
TECHNICAL SPECIFICATIONPerformance data at an operating pressure of 4 bar (cont. flow).
GewichtNominaldiameter
Length Airconsumption
Maximumoperatingpressure
8 1504 0300 600 520 4 3.84 58.0bar m³/min kg
Noiselevel
86dB(A)
Weight
Order no.
AXIAL FAN nominal diameter 600 mmOur most powerful fan with a volume flow of more than 5 m³/s.
Earthing required.
mm mm
Volume flow(unrestricted)
5.83m³/s
GewichtNominaldiameter
Length Airconsumption
Maximumoperatingpressure
bar m³/min kg
Noiselevel
dB(A)
Weight
Order no.
AXIAL FAN nominal diameter 600 mmOur most powerful fan with a volume flow of more than 5 m³/s for use in explosive areas.
Earthing required.
mm mm
Volume flow(unrestricted)
m³/s
ATEXGuideline
2014/34/EU
8 1534 0300 600 520 4 3.84 58.0995.83II2GcIIBT6 (Sub
ject
to c
hang
e w
ithou
t not
ice)
GewichtNominaldiameter
Length Airconsumption
Maximumoperatingpressure
8 1503 0300 500 520 4 2.73 46.0bar m³/min kg
Noise level
90dB(A)
Weight
Order no.
AXIAL FAN nominal diameter 500 mm
mm mm
Volume flow(unrestricted)
4.33m³/s
Built-in fan with increased conveying volume and a volume flow of more than 4 m³/s for use in explosive areas.
Earthing required.
Built-in fan with increased conveying volume and a volume flow of more than 4 m³/s.
Earthing required.
AIR MOVER FEATURES „SPITZJET“
Handle with on/off valve
For ventilation and exhaust
Handle for mobile use
Suction side with venturi nozzle
Earthing cable connectionExhaust side
Air Flow
Air Flow
GewichtNominaldiameter(outer)
Length Volume flow (unrestricted)
TECHNICAL SPECIFICATION
m³/min kg
Noise level(unrestricted)
dB(A)
ATEXGuideline
2014/34/EU
Performance data at an operating pressure of 4-6 bar (cont. flow).
Weight
Order no.
AIR MOVER „SPITZJET“Due to the venturi principle, these robust fans are maintenance-free and free of wear and tear. The practical handle ensures mobile work at universal applications.
Earthing required.
mm mm
Airconsumption
m³/min
6 bar 5 bar 4 bar
m³/min m³/min
Connection
(Sub
ject
to c
hang
e w
ithou
t not
ice)
Additional accessories on request.
8 1614 00108 1616 00108 1618 00108 1620 00108 1622 00108 1624 0010
100125150180200250
410425435450450450
20.526.249.867.578.388.7
3.33.95.25.36.88.0
100.8101.1103.8104.4115.8116.3
II2GcT6II2GcT6II2GcT6II2GcT6II2GcT6II2GcT6
1.6 up to 2.31.7 up to 2.42.8 up to 4.42.9 up to 4.56.3 up to 9.76.4 up to 9.5
17.723.342.762.065.378.9
14.919.636.353.654.367.2
G 3/8“female
G 3/8“female
G 1/2“female
G 1/2“female
G 3/4“female
G 3/4“female
Nominaldiameter(outer)
Length Volume flow (unrestricted)
m³/min kg
Noise level(unrestricted)
dB(A)
ATEXGuideline
2014/34/EU
Weight
Order no.
AIR MOVER „SPITZJET“Due to the venturi principle, these robust stainless steel fans are maintenance-free and free of wear and tear. The practical handle ensures mobile work at universal applications.
Earthing required.
mm mm
Airconsumption
m³/min
6 bar 5 bar 4 bar
m³/min m³/min
Connection
8 1634 00108 1636 00108 1638 00108 1640 00108 1642 00108 1644 0010
101.6129.0154.0168.3204.0219.1
410425435450450450
21.627.452.559.081.583.5
4.85.67.57.79.911.5
100.8101.1103.8104.4115.8116.3
IM2cT6IM2cT6IM2cT6IM2cT6IM2cT6IM2cT6
1.6 up to 2.31.7 up to 2.42.8 up to 4.42.9 up to 4.56.3 up to 9.76.4 up to 9.5
18.221.747.054.268.072.1
15.318.638.346.856.560.8
G 1/2“female
G 1/2“female
G 1/2“female
G 1/2“female
G 3/4“female
G 3/4“female
300 mm9 3709 0260Connecting piece
for fans with nominal diameterDescription 400 mm
9 3709 0270500 mm
9 3709 0280600 mm
9 3709 0290
ACCESSORIES
The connecting piece is an intersection from hose to fan. It can be installed at the suction side and at the discharge side.
CONNECTING PIECE, ANTISTATC
300 mm9 3709 0300Quick-seal coupling
for fans with nominal diameterDescription 400 mm
9 3709 0310500 mm
9 3709 0320600 mm
9 3709 0330
The quick-seal coupling joins the connection and the hose.QUICK-SEAL COUPLING, ANTISTATIC
300 mm9 3709 0220Air duct
for fans with nominal diameterDescription 400 mm
9 3709 0230500 mm
9 3709 0240600 mm
9 3709 0250
The air duct is flexible and adapts itself perfectly to any shape.It can be extended variably by using the quick-seal coupling.
AIR DUCT, ANTISTATIC, 5 m
Select according to nominal diameter (*incl. assembling screws).
300 mm
PROTECTIVE GRILL
8 1501 70108 1501 9010*8 1601 20708 1020 2070
Typ 8 1501 - 8 1534Typ 8 1501 - 8 1534Typ 8 1020, 8 1601-03, 8 1611-13Typ 8 1020 0840, 8 1020 0860
for fans with nominal diameterUsed for 400 mm
8 1502 70108 1502 9010*
500 mm8 1503 70108 1503 9010*
600 mm8 1504 70108 1504 9010*
Required if flanged pipes are to be fitted on suction and/or discharge side. Select according to nominal diameter of fan.
300 mm
FLANGE ACCORDING TO DIN 21603
9 3001 0010According to DIN 21603
for fans with nominal diameterDescription 400 mm
9 3001 0020500 mm
9 3001 0030600 mm
9 3001 0040
The reducing piece adapts the hose diameter to various location situations.ADAPTER
Adapter from diameter 300 mm to diameter 200 mmAdapter from diameter 300 mm to diamater 80 mmAdapter from diameter 300 mm to diameter 100 mmAdapter from diameter 300 mm to diameter 150 mm
Description9 3703 00509 3703 02809 3703 02909 3703 0300
Order no.
Additional accessories on request.
Imperatively required for all axial fans and air movers.Can be used for all fans and SPITZJETS. The total length with clamp is 1.5 m.
EARTHING CABLE
Earthing cable completeDescription
9 3707 0020Order no.
For safety reasons an additional grill should be fitted when used without ducting.1.
3.
2.Pos.
1223
05/1
8E