22
Total Kjeldahl Nitrogen Colorimetric Testing for Discrete and Segmented Flow Analyzers 22nd Annual Good Laboratory Practice Technical Conference 2016 Sarah Leibenguth Technical Support Chemist

Total Kjeldahl Nitrogen Colorimetric Testing for Discrete and … · 2018-04-04 · Total Kjeldahl Nitrogen Colorimetric Testing for Discrete and Segmented Flow Analyzers 22nd Annual

  • Upload
    others

  • View
    9

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Total Kjeldahl Nitrogen Colorimetric Testing for Discrete and … · 2018-04-04 · Total Kjeldahl Nitrogen Colorimetric Testing for Discrete and Segmented Flow Analyzers 22nd Annual

Total Kjeldahl Nitrogen

Colorimetric Testing for Discrete

and Segmented Flow Analyzers

22nd Annual Good Laboratory Practice Technical Conference 2016

Sarah Leibenguth

Technical Support Chemist

Page 2: Total Kjeldahl Nitrogen Colorimetric Testing for Discrete and … · 2018-04-04 · Total Kjeldahl Nitrogen Colorimetric Testing for Discrete and Segmented Flow Analyzers 22nd Annual

Topics for Discussion• Method Principle

• Digestion Protocol

• Temperature

• Digestion Block

• Acid and Salt Content

• Reconstitution

• Catalysts

• Interferences

• Colorimetric Detection

• Distillation Requirements

• Reagents

• Interferences

• pH and Matrix Matching

• Synthetic Diluent

Total Kjeldahl Nitrogen

Page 3: Total Kjeldahl Nitrogen Colorimetric Testing for Discrete and … · 2018-04-04 · Total Kjeldahl Nitrogen Colorimetric Testing for Discrete and Segmented Flow Analyzers 22nd Annual

Method Principle• TKN and Ammonia Colorimetric Reaction

• Hypochlorite

• Ammonia + Hypochlorite → Monochloramine

• pH < 12

• Salicylate

• Monochloramine + Salicylate → Indosalicylate

• Nitroferricyanide

• Catalyst

Total Kjeldahl Nitrogen

Page 4: Total Kjeldahl Nitrogen Colorimetric Testing for Discrete and … · 2018-04-04 · Total Kjeldahl Nitrogen Colorimetric Testing for Discrete and Segmented Flow Analyzers 22nd Annual

TKN Digestion Protocol

Page 5: Total Kjeldahl Nitrogen Colorimetric Testing for Discrete and … · 2018-04-04 · Total Kjeldahl Nitrogen Colorimetric Testing for Discrete and Segmented Flow Analyzers 22nd Annual

Total Kjeldahl Nitrogen Digestion• TKN is Measured as Ammonia by Colorimetric Analysis

• TKN Digestion Converts Organic Nitrogen to Ammonia

• Sulfuric Acid

• Potassium Sulfate

• Heat to 380°C

• Catalyst

• Troubleshooting Digestion Protocol

• Incomplete Digestions

• Sample Acidity Level

Digestion Protocol

Page 6: Total Kjeldahl Nitrogen Colorimetric Testing for Discrete and … · 2018-04-04 · Total Kjeldahl Nitrogen Colorimetric Testing for Discrete and Segmented Flow Analyzers 22nd Annual

Temperature• Potassium Sulfate Increases the Boiling Point to 380°C

• Not all Compounds Decompose at Boiling Point of Sulfuric Acid

• Insures all Compounds Decomposed

• Decreases Time Required for Digestion

• Evaporation Step in Protocol

• Reduces Sample Volume Prior to Temperature Increase

• Decreases Potential for Splatter

• Final Volume Consistency

• Example:

Step to 160°C and Hold for 30 min

Step to 190°C and Hold for 30 min

Approximately 5 mL Final Volume

Digestion Protocol

Page 7: Total Kjeldahl Nitrogen Colorimetric Testing for Discrete and … · 2018-04-04 · Total Kjeldahl Nitrogen Colorimetric Testing for Discrete and Segmented Flow Analyzers 22nd Annual

Draft Shield

Digestion Block

Controller

Digestion Protocol

Page 8: Total Kjeldahl Nitrogen Colorimetric Testing for Discrete and … · 2018-04-04 · Total Kjeldahl Nitrogen Colorimetric Testing for Discrete and Segmented Flow Analyzers 22nd Annual

Temperature• Temperature Stability Across the Block

• Flat Plate Heating and Graphite Rod Heating

• Images of Blocks at 400°C

• Final Sample Volume and Acidity Level

Digestion Protocol

Page 9: Total Kjeldahl Nitrogen Colorimetric Testing for Discrete and … · 2018-04-04 · Total Kjeldahl Nitrogen Colorimetric Testing for Discrete and Segmented Flow Analyzers 22nd Annual

Acid to Salt Content• Samples with High Salt Content

• Brines and Inorganic Salts

• Loss of Nitrogen Above 400°C

• Too Much Acid Leads to Low Recovery

• Approximately 1 mL Sulfuric Acid per 1 g Salt Recommended

• Salt Crystallization

• Crystallization During or After Digestion

• Adjust Flow Rate of Exhaust System

• Aspirator or Scrubber Adjustments

• Adjust Acid Concentration

Digestion Protocol

Page 10: Total Kjeldahl Nitrogen Colorimetric Testing for Discrete and … · 2018-04-04 · Total Kjeldahl Nitrogen Colorimetric Testing for Discrete and Segmented Flow Analyzers 22nd Annual

Reconstitution• Cooling

• Acid Volume Remaining in Digestion Tube

• Solubility of Salt Decreases as Acid Cools

• DI Water Addition – Measured Volume

• Cool Digestion Tubes

• Reconstitute

• Vortex Mixer

• Dispense Accurately

• Bottle Top Dispenser or Auto-Pipette

• Samples and Standards Same Final Volume – Consistent Heating

• Volumetric Digestion Tubes

• Boiling Granule Size and Amount

Digestion Protocol

Page 11: Total Kjeldahl Nitrogen Colorimetric Testing for Discrete and … · 2018-04-04 · Total Kjeldahl Nitrogen Colorimetric Testing for Discrete and Segmented Flow Analyzers 22nd Annual

Catalysts• Mercury

• Documentation

• Reproducibility

• Digestion Time

• Colorless Digest

• Preparing Digestion Reagent

• Filter Prior to Use

• Waste Disposal Considerations

• Copper

• Substitute for Mercury Catalyst

• Possible Increased Digestion Time

• Blue/Green Final Digest

• Less Toxic Alternative

Digestion Protocol

Page 12: Total Kjeldahl Nitrogen Colorimetric Testing for Discrete and … · 2018-04-04 · Total Kjeldahl Nitrogen Colorimetric Testing for Discrete and Segmented Flow Analyzers 22nd Annual

Interferences• High Salt Content

• Acid to Salt Ratio

• Boiling Point

• Nitrogen Loss

• High Nitrate and Nitrite

• Excess of 10 mg/L

• Oxidation State

• Positive or Negative Interference

• Organic Matter

• Consumption of Acid

• Digestion Tube Considerations

Digestion Protocol

Page 13: Total Kjeldahl Nitrogen Colorimetric Testing for Discrete and … · 2018-04-04 · Total Kjeldahl Nitrogen Colorimetric Testing for Discrete and Segmented Flow Analyzers 22nd Annual

TKN Colorimetric Reaction

Page 14: Total Kjeldahl Nitrogen Colorimetric Testing for Discrete and … · 2018-04-04 · Total Kjeldahl Nitrogen Colorimetric Testing for Discrete and Segmented Flow Analyzers 22nd Annual

Distillation Requirements• Distillation

• EPA Requirements

• 40 CFR 136.3

• Automated Digestion Block to Automated Analyzer

• Sample pH

• Colorimetric Detection by Automated

• Strong Buffer

• Sample pH

• Conversation from Ammonium to Ammonia

• Buffer Aids in Colorimetric Reaction

Colorimetric Detection

Page 15: Total Kjeldahl Nitrogen Colorimetric Testing for Discrete and … · 2018-04-04 · Total Kjeldahl Nitrogen Colorimetric Testing for Discrete and Segmented Flow Analyzers 22nd Annual

Reagents• Sodium Hypochlorite

• Purchased Reagents

• Expiration Dates

• Bleach Stable 1 Month if Opened

• Solution is Unstable

• Chlorine Evaporates if Exposed to Air

• Reduced Free Chlorine Concentration

• Store in Refrigerator

• Sodium Hypochlorite Volatizes in Heat

• DCI Stable 1 Day in Solution

• Dry Chemical Storage

Colorimetric Detection

Page 16: Total Kjeldahl Nitrogen Colorimetric Testing for Discrete and … · 2018-04-04 · Total Kjeldahl Nitrogen Colorimetric Testing for Discrete and Segmented Flow Analyzers 22nd Annual

Reagents• TKN Buffer Solution

• Store at Room Temperature

• Extended Shelf Life

• Some Recipes Include EDTA or Sodium Potassium Tartrate

• pH Adjustments

• Sodium Potassium Tartrate

• Ammonia Contamination

• Alkaline Boil for 1 Hour

• Adjust pH between 7 and 8

• Purchase from Vendor

• Stable 6 Months in Solution

Colorimetric Detection

Page 17: Total Kjeldahl Nitrogen Colorimetric Testing for Discrete and … · 2018-04-04 · Total Kjeldahl Nitrogen Colorimetric Testing for Discrete and Segmented Flow Analyzers 22nd Annual

Reagents• Salicylate

• Refrigerate and Store in Amber Bottle

• Stable 1 Month

• Filtration

• Precipitates in Acidic Conditions

• Nitroferricyanide

• Stable 1 Month

• Discard if Blue in Color

Colorimetric Detection

Page 18: Total Kjeldahl Nitrogen Colorimetric Testing for Discrete and … · 2018-04-04 · Total Kjeldahl Nitrogen Colorimetric Testing for Discrete and Segmented Flow Analyzers 22nd Annual

Interferences• Calcium and Magnesium

• Precipitation

• Addition of EDTA or Sodium Potassium Tartrate

• Turbidity or Color

• Interference for Colorimetric Reactions

• Filtration Post-Digestion

Colorimetric Detection

Page 19: Total Kjeldahl Nitrogen Colorimetric Testing for Discrete and … · 2018-04-04 · Total Kjeldahl Nitrogen Colorimetric Testing for Discrete and Segmented Flow Analyzers 22nd Annual

pH and Matrix Matching• Testing Reaction pH

• Phenate pH 12 to 12.4

• Salicylate pH 12.6 to 13.1

• Segmented Flow Testing

• Discrete Testing

• Sodium Hypochlorite

• Age of Hypochlorite Solution

• Purchasing New Reagent Solution

Colorimetric Detection

Page 20: Total Kjeldahl Nitrogen Colorimetric Testing for Discrete and … · 2018-04-04 · Total Kjeldahl Nitrogen Colorimetric Testing for Discrete and Segmented Flow Analyzers 22nd Annual

pH and Matrix Matching• Preserved Samples

• Adjustments in Buffer Solution

• Many Methods Include Modification

• Matrix Matching

• Sample Preservation

• Digested Blanks with Matching Preservation

• Synthetic Diluent

Colorimetric Detection

Page 21: Total Kjeldahl Nitrogen Colorimetric Testing for Discrete and … · 2018-04-04 · Total Kjeldahl Nitrogen Colorimetric Testing for Discrete and Segmented Flow Analyzers 22nd Annual

Synthetic Diluent

• Prepare Solution with Same Acidity Level as Final Digest

• Test for Organic Nitrogen Contamination in Digestion Reagent

• Addition of Copper Sulfate

• Troubleshoot

• pH

• Linearity

• Contamination

Colorimetric Detection

Page 22: Total Kjeldahl Nitrogen Colorimetric Testing for Discrete and … · 2018-04-04 · Total Kjeldahl Nitrogen Colorimetric Testing for Discrete and Segmented Flow Analyzers 22nd Annual

Questions?