TrueSight Operations Management - Hitachi Storage STORAGE MONITORING USER DOCUMENTATION Version 1.5.00 September 2017

TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

  • Upload
    ngoanh

  • View
    233

  • Download
    0

Embed Size (px)

Citation preview

Page 1: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

TrueSight Operations Management -Hitachi Storage

STORAGE MONITORING

USER DOCUMENTATION

Version 1.5.00

September 2017

Page 2: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

Contacting BMC Software

You can access the BMC Software Web site at http://www.bmc.com. From this Web site, you canobtain information about the company, its products, corporate offices, special events, and careeropportunities.

United States and Canada

Address BMC Software, Inc.2101 CityWest Blvd. Houston TX77042-2827

Telephone 1 (713) 918 8800 or 1 (800) 841 2031 (Toll Free)

Copyright 2015 BMC Software, Inc. or licensors, as an unpublished work. All rights reserved.

BMC Software, the BMC Software logos, and all other BMC Software product or service names areregistered trademarks or trademarks of BMC Software, Inc.

All other trademarks belong to their respective companies.

BMC Software considers information included in this documentation to be proprietary andconfidential. Your use of this information is subject to the terms and conditions of the applicableEnd User License Agreement for the product and the proprietary and restricted rights noticesincluded in this documentation.

Restricted Rights Legend

U.S. Government Restricted Rights to Computer Software. UNPUBLISHED -- RIGHTS RESERVEDUNDER THE COPYRIGHT LAWS OF THE UNITED STATES. Use, duplication, or disclosure of any dataand computer software by the U.S. Government is subject to restrictions, as applicable, set forthin FAR Section 52.227-14, DFARS 252.227-7013, DFARS 252.227-7014, DFARS 252.227-7015, andDFARS 252.227-7025, as amended from time to time. Contractor/Manufacturer is BMC Software,Inc., 2101 CityWest Blvd., Houston, TX 77042-2827, USA. Any contract notices should be sent to thisaddress.

2

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

Page 3: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

Customer Support

You can obtain technical support by using the Support page on the BMC Software Web site or bycontacting Customer Support by telephone or e-mail.

Support Web Site

You can obtain technical support from BMC Software 24 hours a day, 7 days a week at http://www.bmc.com/support_home. From this Web site, you can:

Read overviews about support services and programs that BMC Software offers

Find the most current information about BMC Software products

Search a database for problems similar to yours and possible solutions

Order or download product documentation

Report a problem or ask a question

Subscribe to receive e-mail notices when new product versions are released

Find worldwide BMC Software support center locations and contact information, including e-mail addresses, fax numbers, and telephone numbers

You can also access product documents and search the Knowledge Base for help with an issue at http://www.sentrysoftware.com

Support by Telephone or E-mail

In the United States and Canada, if you need technical support and do not have access to the Web,call 800 537 1813. Outside the United States and Canada, please contact your local support centerfor assistance. To find telephone and email contact information for the BMC Software supportcenter that services your location, refer to the Contact Customer Support section of the Supportpage on the BMC Software Web site at http://www.bmc.com/support_home.

3

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

Page 4: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

4

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

Table of Contents.....................................................................................................................................................................................9User Goals and Features

.....................................................................................................................................................................................9Product at a Glance

.....................................................................................................................................................................................10Supported Platforms

.....................................................................................................................................................................................12Prerequisites

.......................................................................................................................................................................................13Monitoring Hitachi AMS, HUS, USP, and VSP Systems

......................................................................................................................................................................13Installing Hitachi Device Manager

..........................................................................................................................................................................13Installing the Hitachi Command Suite

..........................................................................................................................................................................16Installing the Device Manager Agent

..........................................................................................................................................................................23Configuring the Hitachi Device Manager

......................................................................................................................................................................31Enabling Statistics

.......................................................................................................................................................................................33Monitoring Hitachi VSP Gxxxx Series Systems

......................................................................................................................................................................33Starting the Embedded SMI-S Provider

......................................................................................................................................................................33Creating a User with "storage administrator View-only" Role

......................................................................................................................................................................33Enabling Statistics

.....................................................................................................................................................................................36Importing the Monitoring Solution into Central Administration

.....................................................................................................................................................................................37Creating the Installation Package

.....................................................................................................................................................................................38Downloading the Installation Package

.....................................................................................................................................................................................38Installing the Package

.....................................................................................................................................................................................40Configuring Monitor Settings

.......................................................................................................................................................................................44Customizing the Discovery and Polling Intervals

.......................................................................................................................................................................................46Enabling/Disabling Volumes Monitoring

.......................................................................................................................................................................................47Customize Discovery and Collect Timeouts

.......................................................................................................................................................................................49Enabling the Debug Mode

.......................................................................................................................................................................................50Managing Advanced Configuration Variables

.......................................................................................................................................................................................53Scheduling Automatic Reports

.......................................................................................................................................................................................54Configuring Alert Actions

.....................................................................................................................................................................................59Creating Consolidated Data Views with Dashboards

.......................................................................................................................................................................................60Detecting Unbalanced Workload Distribution on Controllers

.......................................................................................................................................................................................63Identifying Busiest Volumes

.......................................................................................................................................................................................66Reporting Disk Space Consumption

.....................................................................................................................................................................................71Hitachi Disk Array

.....................................................................................................................................................................................72Hitachi Controller

Page 5: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

5

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

.....................................................................................................................................................................................73Hitachi Fiber Port

.....................................................................................................................................................................................74Hitachi Device Manager

.....................................................................................................................................................................................75Hitachi Managed Array

.....................................................................................................................................................................................76Hitachi Storage Pool

.....................................................................................................................................................................................77Hitachi Volume

.....................................................................................................................................................................................78Managing Baselines and Key Performance Indicators

Page 6: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

Release Notes for v1.5.00

Page 7: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

7

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

What's NewSENHDS-113: Hitachi Storage Monitoring now discovers and reports on iSCSI-mappedvolumes (HDS G-Series only). iQNs (iSCSI Qualified Names) are displayed in the LUNsMapping Table report.

SENHDS-1087: Hitachi Storage Monitoring now supports Hitachi Unified Storage VM (HUS VM)through the Hitachi Embedded SMI-S Provider.

Changes and ImprovementsSENHDS-1099 : Hitachi Storage Monitoring requires Java 1.8.00 or higher to perform properly.

SENHDS-1099: Changes have been implemented to enhance the performance and behavior ofthe Collection Hub:

Hitachi Storage Monitoring now uses its exclusive Collection Hub instance. Therefore, filesare no longer shared with other KMs to prevent compatibilities issues.

The Collection Hub debug files provide more detailed information about its operations.

SENHDS-1099: The overall performance of remote Windows commands analysis has beensignificantly improved.

Fixed IssuesHitachi Storage Monitoring now supports multiple alert actions used in combination withmacros when importing a PATROL classic configuration into a CMA policy.

SENHDS-1099: The Collection Hub now supports a larger amount of simultaneous requeststimeouts.

SENHDS-1059: Some VSP Gxxxx Series' volumes sharing the same label were not properlydiscovered.

Page 8: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

Overview

Page 9: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

9

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

The pages in this section provide a high-level overview of the product.

User Goals and Features

Product at a Glance

Supported Platforms

Note that for convenience and brevity, reference to TrueSight Operations Management - Hitachi Storage,may also be made as Hitachi Storage Monitoring.

User Goals and FeaturesTrueSight Operations Management - Hitachi Storage allows you to view, monitor, and manageyour entire Hitachi storage environment by viewing the current and historical informationthrough a centralized console. You can view detailed system metrics on all parts of yourenvironment, such as:

Disk arrays: size, consumed and subscribed capacity, I/Os throughput...

Controllers: Hit ratio, data traffic...

Storage pools: Thin provisioning metrics, size and type...

Volumes: data traffic, hit ratio, time utilization, response time...

Ports: Data traffic statistics, bandwidth utilization, I/Os throughput...

Product at a GlanceTrueSight Operations Management - Hitachi Storage provides current and historical informationthrough a centralized console so you can easily view and manage your entire Hitachienvironment. The product collects and brings critical performance data and useful metrics intothe BMC TrueSight Operations Management environment and enables SAN Administrators to bewarned whenever a problem occurs in their Hitachi environment.

Page 10: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

10Product at a Glance

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

Hitachi Storage Monitoring - Architecture Diagram

TrueSight Operations Management - Hitachi Storage:

collects storage performance and metrics to keep total control of your SAN environment

identifies performance bottlenecks (arrays, volumes, storage pools, etc.)

manages and helps rationalize disk space consumption

detects oversubscription situations (thin provisioning).

Supported PlatformsBMC Framework

BMC ProactiveNet 9.0 and higher

BMC ProactiveNet Central Monitoring Administration 9.0 and higher

BMC TrueSight Operations Management 10

PATROL Agent

TrueSight Operations Management - Hitachi Storage supports PATROL Agent v3.9 and higher.

JAVA

TrueSight Operations Management - Hitachi Storage requires Java 1.8.00 or higher and a Java RunEnvironment (JRE) to be installed on the same system that the PATROL Agent.A package with a suitable Java Runtime Environment, designed for use with the BMC Software

Page 11: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

11 Supported Platforms

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

Installation Utility, is made available to download on the Sentry Software Web site.

Hitachi Storage Systems

ModelsSupported Versions

HitachiDevice Manager v7.31

HitachiDevice Manager v8.1.41

HitachiEmbedded SMI-S Provider

Hitachi AdaptableModular Storage 2000family (AMS)

Hitachi Unified Storage(HUS)

Hitachi Unified StorageVM (HUS VM)2

Hitachi UniversalStorage Platform (USP,USP-V/USP-VM)2

Hitachi Virtual StoragePlatform (VSP) - Systemswith Basic OperatingSystem (BOS)

Hitachi VSP G Series (VSPG200, G400, G600, G800and G1000)3

HP XP P9000

HP XP P9500

1 Tested and validated with Hitachi Device Manager v7.3 Build 0730-06 and v8.1.4 Build 0814-06. Formore recent versions, please contact our support team.

2 The support of Hitachi HUS VM disk arrays is available only if you apply the Feature Pack 1 (10.7.01)of TrueSight Capacity Optimization 10.7. Tested and validated with the Hitachi embedded SMI-S withMicrocode 73-03-50-00/00 for the Storage system.

3 Tested and validated with the Hitachi embedded SMI-S provider v1.5.0; with Microcode 83-03-22-20/00for the Storage system.

Page 12: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

12Prerequisites

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

PrerequisitesIntegrated as a native module for BMC TrueSight Operations Management, TrueSight OperationsManagement - Hitachi Storage is designed to monitor the health and performance of yourmanaged environment. Prior to install the KM, make sure that the following prerequisites aremet.

BMC FrameworkPATROL Agent, version 3.9 or higher (see BMC PATROL documentation)

PATROL Console (see BMC PATROL documentation)

Java 1.6 or higher (installed on the system where the PATROL Agent runs)

Hitachi AMS, HUS, USP, VSP Systems

Hitachi Device Manager must be properly installed and the statistics enabled. Refer toMonitoring Hitachi AMS, HUS, USP, and VSP Systems for more details.

Hitachi VSP Gxxxx Series SystemsThe embedded SMI-S provider must be started

A User with "storage administrator View-only" role must be created

Statistics must be enabled.

Refer to Monitoring Hitachi VSP Gxxxx Series Systems for more details.

Page 13: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

13 Prerequisites

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

Monitoring Hitachi AMS, HUS, USP, and VSPSystemsBefore installing TrueSight Operations Management - Hitachi Storage, you must ensure thatHitachi Device Manager is properly installed and statistics are enabled.

Installing Hitachi Device ManagerBefore installing the Hitachi Device Manager, make sure that:

The server’s definitive name has been set. The installation of this software setsconfiguration variables based on the server’s DNS Name.

Adobe Flash Player is installed.

Monitoring history will be lost when upgrading to Hitachi Device Manager v.8.

Installing the Hitachi Command Suite

The installation files are contained on the Hitachi Device Manager Server DVD.

1. Double-click the Index.html file

Page 14: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

14Prerequisites

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

2. Click Install to launch the Hitachi Command Suite installer:

3. Click Next.

Page 15: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

15 Prerequisites

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

4. Choose the installation folder and click Next.

5. Click Install.

Page 16: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

16Prerequisites

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

6. When the installation is complete, click Finish.

7. Open the Hitachi Command Suite: http://<IP_Address>:22015/DeviceManagerWebService/index.jsp

8. Click on License and Install License.

Installing the Device Manager Agent1. Log into the Hitachi Command Suite Console: http://<IP_Address>:22015/

DeviceManagerWebService/index.jsp

Page 17: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

17 Prerequisites

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

2. Click Install to launch the Device Manager agent installer:

3. Click Next.

Page 18: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

18Prerequisites

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

4. Select the I accept the terms of the License Agreement option and click Next

5. Choose the install folder and click Next. A screen will appear to ask you permission to add afirewall exception even if your server’s firewall is not enabled:

Page 19: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

19 Prerequisites

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

6. Select YES and click Next.

7. Select the user account to be used for launching the agent service. Selecting NO will use theLocal System Account (recommended). Click Next.

Page 20: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

20Prerequisites

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

8. Click Install.

9. When the installation is complete, click Yes to setup the Device Manager agent. The agentwill then check connection to Device Manager (Hitachi’s Name for Command View AdvancedEdition).

Page 21: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

21 Prerequisites

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

10. Select YES to specify the Device Manager server Information, change the IP address to127.0.0.1 and click Next.

11. Click OK.

Page 22: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

22Prerequisites

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

12. Select YES to enable the Execution Period of the HiScan Command. Select pre-determined orrandom hour (do not use the default 2:30am) to prevent agent conflict. Click Next.

13. Select NO in order not to set up the RAID Manager (it is not needed by Sentry / CVAE) andclick Next.

14. A message "The Device Manager agent setup has completed successfully" appears. Click OKto finish the installation.

Page 23: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

23 Prerequisites

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

Configuring the Hitachi Device Manager1. Log into the Hitachi Command Suite Console: http://<IP_Address>:22015/

DeviceManagerWebService/index.jsp

2. Click the Add Storage System button located under the Administration > Storage Systemstabs:

3. Select the Storage System Type.

For Hitachi Series Storage System (VSP / USP-V), provide the IP address and Credentials:

For Hitachi Series Storage System (AMS), provide the Controller’s IP addresses andCredentials:

Page 24: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

24Prerequisites

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

4. Click OK. A Data Collection Task will be generated to add the Storage System. Click View TaskStatus for details.

5. Wait for the Data Collect Task to complete successfully.

6. (USP-V and VSP only) Create the Administrative LUN:

Click the Resources tab.

Expand all storage systems and select the recently added storage system.

Select Volumes.

Under General Tasks, select Allocate Volume and fill the fields as follows:

Host: for Physical Servers, the name of the host where CVAE is installed; for VirtualServers on ESX host, the name of the ESX host server.

Size: Can be as small as 50MB since this LUN will not actually have data.

VolumeType: Basic Volume

Page 25: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

25 Prerequisites

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

Location: Internal

Click Show Plan.

Verify that the allocation task has completed correctly:

7. Make the Volume/LUN a Command Device:

Log into the Storage System.

Expand the Storage System folder and select Logical Devices.

Select the Logical Device (LUN / Volume) that you want to make a Command Device.

Click More Actions > Edit Command Devices.

Page 26: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

26Prerequisites

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

8. Enable the logical device as a Command Device:

9. (Virtual Machines on ESX hosts only / For physical hosts, skip this section) Raw DeviceMapping or LUN allocation will not work for Virtual Machines on ESX Hosts. The HBA port orHBA Card must be allocated directly to the VM. The server needs to be vt-d compatible andhave sufficient free HBA ports for each instance of the SMI-S provider you require. To allocate a port for passthrough:

Under the ESX Host’s Configuration tab, select Advanced Settings and click ConfigurePassthrough:

Page 27: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

27 Prerequisites

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

Select the HBA port(s) that you wish to allocate to VMs:

Click OK.

Restart the ESX Server.

Add the HBA ports to the Virtual Machine:

Page 28: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

28Prerequisites

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

Once the VM or Physical server sees the LUN, Windows should find a new hard drive:

Click OK to create an MBR (Master Boot Record).

Run the following command: C:\Program Files (x86)\HDVM\HBaseAgent\bin>perf_findcmddev.exe view

Page 29: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

29 Prerequisites

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

If the Storage System does not appear, run: C:\Program Files (x86)\HDVM\HBaseAgent\bin\hldutil

Refer to the RAID ID Translation Table below to find the OPEN-V-CM (command deviceLUN) for the storage system:

R700 for VSP

R600 for USP-V

R601 for USP-VM

10. Edit the file: C:\Program Files (x86)\HDVM\HBaseAgent\mod\hdvm\config\typeperf_cmddev.properties

11. Translate the information from hldutil to perf_cmddev.properties Disk1 HITACHI OPEN-V-CM CL1-A 0 0 00:8C 14EAE

R700 0-0 2100001B3284D3DD 2000001B3284D3DD

R700.85678.0.140 : \\.\PhysicalDrive1

The Disk Number and Model number can be copied directly.

Page 30: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

30Prerequisites

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

The Serial, CU, and LDEV Number need to be translated from HEX to Decimal.

Run perf_findcmddev view to check configuration:

Run perf_findcmddev verify to ensure configuration is valid:

The verify command will highlight any invalid or non-functional lines in the configuration:

If the configuration is valid, use the perf_findcmddev write command to save theconfiguration. Any invalid configuration lines (such as PhysicalDrive2 in the example abovewill be removed from the configuration by the write command.

12. Configure the Hitachi Command View server to use the agent:

Edit Hitachi\HiCommandServer\config\server.properties

Search for the following line: # host name for the CIM agent

server.cim.agent=

Page 31: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

31 Prerequisites

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

13. Add the hostname for the CIM agent. The hostname should be the short, non-FQDN of theserver: # host name for the CIM agent

server.cim.agent=Hitachi-SMIS

14. If the server is the same as the agent (by default), take the hostname from the servervariable: server.http.host= Hitachi-SMIS

15. Restart the Server (or restart all Hitachi Services).

16. Log into Hitachi Command View Server after reboot to ensure that it is working.

Enabling StatisticsOn Hitachi storage systems, the statistics need to be enabled to allow TrueSight OperationsManagement - Hitachi Storage to monitor performance.

Log on to the Hitachi Storage Navigator Modular console with the administrator’s account.

1. In the left pane menu, expand Resource. Click Arrays.

2. Select the array from the Array Name list. The interface corresponding to the selected diskarray opens.

Selecting the array from the Array Name list

Page 32: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

32Prerequisites

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

3. In the tree view related to your disk array, click Performance > Monitoring.

Enabling Statistics - Monitoring

4. Click the Change Measurement Items button to display the Performance MeasurementItems Property.

Enabling Statistics - Changing measurement items

5. Check each item check-boxes and click OK to finish.

Page 33: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

33 Prerequisites

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

Monitoring Hitachi VSP Gxxxx Series SystemsSince TrueSight Operations Management - Hitachi Storage leverages the embedded SMI-Sprovider to collect metrics about Hitachi VSP Series systems, there is no need to install aseparate SMI-S provider. The only steps to follow are:

Starting the Embedded SMI-S provider

Creating a User with "storage administrator View-only" Role

Enabling Statistics

Starting the Embedded SMI-S ProviderTo start the embedded SMI-S Provider:

1. Click Start > All Programs > Hitachi Device Manager - Storage Navigator > StorageDeviceList

2. Click Start Service

3. Run the netstat -ano|findstr 5989 command to verify that a process is actually listening onport 5989.

Creating a User with "storage administrator View-only"

RoleTo create a user with the “storage administrator View-only” role:

1. Log on to the Hitachi Device Manager - Storage Navigator console

2. In the left pane, click Administration > Storage Administrator (View Only) User Group

3. In the right pane, select the Users tab and click Create User

4. Enter the required information and click Finish.

Enabling StatisticsStatistics need to be enabled to allow Hitachi Storage Monitoring to collect performance metrics.The procedure is as follows:

1. Log on to the Hitachi Storage Navigator Modular console with the administrator’s account.

2. In the left pane, click Analytics > Performance Monitor

3. Click Edit Monitoring Switch

4. In the Edit Monitoring Switch window, select Enable and click Finish.

Page 34: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

Installing the Monitoring Solution

Page 35: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

35

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

Once the latest version of the solution has been loaded into Central Monitoring Administration,administrators can create all the installation packages required for their different operatingsystems and platforms and save them for later use in the Monitoring Installation Packages list.These packages can then be deployed to multiple computers. Administrators just have toconnect to TrueSight Operations Management from the server where they want to install thepackage, download it and launch the installation.

This section describes the different steps to follow to install Hitachi Storage Monitoring:

Importing Hitachi Storage Monitoring into Central Monitoring Administration

Creating the Installation Package

Downloading the Installation Package

Installing the Package

Page 36: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

36

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

Importing the Monitoring Solutioninto Central AdministrationThe TrueSight Central Monitoring Repository includes the current versions of TrueSightOperations Management - Hitachi Storage that you can use with BMC TrueSight. If the versionavailable in the Repository does not correspond to the latest one, you will have to manuallyimport it:

1. Log on to the BMC TrueSight Operations Management Console.

2. Launch Central Monitoring Administration.

3. Click the Repository drawer and select Manage Repository.

4. Check that the version of the BMC component available is actually the latest one. If not,download the latest version corresponding to your operating system (Windows or UNIX/Linux) available on the Sentry Software Website.

5. From TrueSight Operations Management, click Import .

6. Select Single solution.

7. Browse to the .zip source file.

8. Click Import.

The selected archive file is imported to the repository.

Page 37: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

37 Importing the Monitoring Solution into CentralAdministration

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

Creating the Installation PackageThe installation package to deploy to managed systems can be created directly from TrueSightOperations Management:

1. Log on to TrueSight Operations Management

2. Click the Repository drawer and select Deployable Package Repository.

3. Click Add .

4. Select the operating system and platform for which you want to create a package. Thecomponents available in the repository for the selected operating system and platform aredisplayed.

5. Select the Installation Package Component:

From the Available components list, select the relevant component.

From the Version list, select the latest version.

Click the right arrow button to move the component into the Selected Components list.By default, the appropriate BMC PATROL Agent for the operating system and platform thatyou chose is included in the Selected components list.

Click Next. The Add Component Installation Package wizard are displayed.

6. Go through the wizard and specify the required PATROL information. The InstallationPackage Details is displayed.

7. Verify that:

the operating system and platform are correct

the components that you want to include are listed in the Included Components list.

8. Provide the following information:

Name: Enter a unique name for the package.

(Optional) Description: Enter a description of the package. The description is displayed inthe Monitoring Installation Packages list on the Monitoring Repository window.

Format: Select a file compression format for the package.

9. Click Save Installation Package.

10. Click Close. The package is now available in the Monitoring Installation Packages list.

Page 38: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

38Creating the Installation Package

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

Downloading the Installation PackageYou can download an installation package and install the components on one or more hosts. Theinstallation runs silently with the information entered during package creation.

RecommendationIf you defined the BMC TrueSight Integration Service variable for PATROL Agents in theinstallation package, ensure the agents are started in phases. Do not start newly deployedagents all at once. Start and configure monitoring for the agents in planned phases to reducethe performance impact on the Integration Service nodes and on the BMC TrueSight Serverassociated with the automatic workflow process.

1. Log on to TrueSight Operations Management from the computer on which the PATROL Agentis installed or to be installed.

2. Click the Repository drawer and select Deployable Package Repository.

3. (Optional) To filter the list of installation packages, select an operating system from the Filter by Operating System list.

4. Click the link for the installation package that you want to download.

5. Through the browser's download dialog box, save the installation package.

Installing the PackageThis chapter provides a step by step procedure to install a monitoring solution package:

1. From the computer on which you want to install the package, log on to TrueSight OperationsManagement.

2. (Optional) To filter the list of installation packages, select an operating system from the Filter by Operating System list.

3. Click the link for the installation package that you want to download.

4. Through the browser's download dialog box, save the installation package in a temporaryfile.

5. Extract the installation package that is appropriate for your operating system. The package isextracted to the bmc_products directory on the current host.

6. From the bmc_products directory, run the installation utility for your operating system:

(UNIX or Linux) RunSilentInstall.sh

(Microsoft Windows) RunSilentInstall.exe

The package is installed on the current host. If the package includes a BMC PATROL Agent, theagent sends a configuration request by passing its tags to Central Monitoring Administration, viathe Integration Service. Central Monitoring Administration evaluates policies that match thetags, determines the final configuration to be applied, and sends the configuration informationback to the agent. Monitoring is based on the configuration information received by the agent.

Page 39: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

Configuring After Installation

Page 40: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

40Configuring Monitor Settings

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

Configuring Monitor SettingsThe configuration of Monitor Types is performed through policies. Policies enable you to deployconfigurations on PATROL Agents and monitoring solutions, such as Hitachi Storage Monitoring inan automated way. Policies are designed to define and configure monitoring criteria and applythem to selected PATROL Agents. The configuration criteria are automatically pushed to thePATROL Agents on which the policy is applied. When a monitoring policy is applied to a PATROLAgent, the device is automatically added to the list of monitored devices.

To create a monitoring policy1. Log on to the TrueSight console.

2. In the navigation pane, expand Configuration and select Infrastructure Policies.

3. In the Infrastructure Policies page, ensure that the Monitoring tab is selected and clickCreate Policy.

4. In the Create Monitoring Policy page, specify the monitoring policy properties:

Step 1 - Define the General Properties

Property Description

Name Name for the policy. The policy names must be unique. In an environment with tenants, thepolicy names must be unique for a single tenant. It is a mandatory field.

Description (Optional) A brief description about the policy.

Associated UserGroup

Name of the user group that is associated with the PATROL Agents as defined in theAuthorization Profile or in the PATROL Agent ACLs. The policy is applicable to thesePATROL Agents.

Share with UserGroup

Specify whether this policy is to be shared with the users across the associated usergroup or not. This property can be viewed in READ-ONLY mode by other users of theassociated user group. Only the owner of the policy can modify this property.

Precedence Priority of the policy. Based on the precedence number that you configure, theconfiguration is applied to the PATROL Agents and the Infrastructure Management servers.The precedence number ranges from 0 to 999. A lower number indicates a higherprecedence. The default value is 900.The configuration from a policy with a higher precedence overrides the configuration froma policy with a lower precedence. If two policies have the same precedence number, thenthe configuration from the latest created policy takes priority.

Enable Policy Indicates whether the policy is enabled or disabled. By default, the policy is enabled. Ifyou disable a policy when you create it, the policy configurations are not applied to thePATROL Agents and the Infrastructure Management Servers. If you disable any existingpolicy, the policy configurations are removed from the PATROL Agents and theInfrastructure Management servers, where the policy was applied.

Step 2 - Select the PATROL AgentsDefine conditions to select the PATROL Agents on which you want to apply the policy:

Page 41: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

41 Configuring Monitor Settings

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

1. Select a property.

2. Select an operator to create the condition. The available operators depend on the propertythat you select.

3. Specify a value for the selected property.

4. (Optional) To add more than one condition, click the button, and perform the earliersteps.

5. (Optional) To group the conditions, use the parentheses and Boolean operators from theircorresponding lists.

The Add Monitor Types dialog box presents configuration fields for compatible BMC PATROLmonitoring solutions that are located in the Central Monitoring Repository.

Step 3 - Select the Hitachi Storage Monitor Type1. Click the Monitoring tab.

2. Click Add Monitoring Configuration.

3. In the Add Monitoring Configuration dialog box, configure the properties:

From the Monitoring Solution menu, select Hitachi Storage.

From the Version menu, select the required version.

The Monitor Profile is automatically selected.

Page 42: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

42Configuring Monitor Settings

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

Step 4: Add a Monitoring Configuration1. In the Hitachi Storage Configuration section, click Add to open the Embedded SMI-S

Provider/Hitachi Device Manager settings panel.

Embedded SMI-S Provider/Hitachi Device Manager Global Settings

2. In the Global Settings section, define the Connection Settings to access the Embedded SMI-SProvider/Hitachi Device Manager:

Hostname: hostname of the system where the Embedded SMI-S Provider/Hitachi DeviceManager is running

Port Number: By default, the Embedded SMI-S Provider/Hitachi Device Manager runs onport 5989 when the encryption option is enabled, or on port 5988 when the encryption isdisabled.

Encryption: Select this option to encrypt the connection.

Enter the WBEM Credentials that will be used to connect to the Embedded SMI-S Provider/

Page 43: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

43 Configuring Monitor Settings

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

Hitachi Device Manager.

3. In the Refresh Hitachi Information section, indicate how often the Hitachi Information will berefreshed (Never, Every Hour, or Once A Day). This automatic refresh is required to makesure that configuration changes are taken into account by Hitachi Device Manager. Note thatrefreshing the Embedded SMI-S Provider/Hitachi Device Manager is resource intensive andtime consuming.

4. (Optional) - Customize the following settings:

Discovery and Polling Intervals

Volume Monitoring Conditions

Discovery and Collect Timeout

5. Click OK to save your settings.

Step 5: Configure other settings1. From the Add Monitoring Configuration panel, you can perform the following operation:

Enable/disable the debug mode

Manage configuration variables

Schedule automatic reports

Configure global alert actions

2. Click OK to validate.

To edit a monitoring policy1. Log on to the TrueSight console.

2. In the navigation pane, expand Configuration and select Infrastructure Policies.

3. In the Infrastructure Policies page, locate the monitoring policy you wish to modify, click its

action button and click Edit.

4. In the Edit Monitoring Policy page, locate the monitoring configuration you wish to modify

and click its action button to access the monitoring options panel.

5. Customize the configuration.

6. Click Save to apply your changes to the selected PATROL Agent(s).

Page 44: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

44Configuring Monitor Settings

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

Customizing the Discovery and PollingIntervalsTrueSight Operations Management - Hitachi Storage periodically performs discoveries to detectnew components in your monitored environment. By default, the solution runs a discovery everyhour, but you can customize this interval to match your specific needs.

Hitachi Storage Monitoring also polls the managed systems to collect hardware health data. Bydefault, the polling interval for this "data-collect" is set to every 2 minutes.

To customize the discovery and polling intervals1. Create a new policy or edit an existing policy.

2. In the Add Monitoring Configuration panel, scroll down to the Optional Settings section.

Customizing the Discovery and Polling Intervals

Page 45: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

45 Configuring Monitor Settings

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

3. Enter the frequency (in minutes) of the discovery process. By default, the discovery intervalis set to 60 minutes.

4. Enter the interval at which the solution must poll the managed systems to collect hardwarehealth data. By default, the polling interval is set to 2 minutes.

5. Click OK to save your settings.

Page 46: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

46Configuring Monitor Settings

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

Enabling/Disabling Volumes MonitoringBy default, the solution discovers and monitors all volumes in the storage systems. There may bea very large number of volumes to monitor and this may represent an important workload to theAgents and the servers. Hitachi Storage Monitoring enables you to completely disable themonitoring of volumes or to filter the specific volumes you want to monitored.

To enable/disable volumes monitoring1. Create a new policy or edit an existing policy.

2. In the Add Monitoring Configuration panel, scroll down to the Optional Settings section.

Enabling/Disabling Volumes Monitoring

Page 47: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

47 Configuring Monitor Settings

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

3. Check the Disable Volumes Monitoring option if you want to completely exclude all volumesfrom your monitored environment to limit the number of volume instances created andtherefore reduce the system resource consumption. Discovery and collect requests as well asany other operations will no longer be performed on volumes.

4. Click OK to save your settings.

To filter monitored volumes

You can filter the volumes that will be monitored by excluding volumes you do not want tomonitor or identifying those you want to keep on monitoring:

1. In the Exclude Volumes field, enter the names of the volumes that will be excluded frommonitoring process. A regular expression can also be used to identify volumes.

2. In the Keep Only Volumes field, enter the names of the volumes to be monitored. A regularexpression can also be used to identify volumes.

3. Click OK to save your settings.

Customize Discovery and Collect TimeoutsTrueSight Operations Management - Hitachi Storage periodically performs discoveries to detectnew components in your monitored environment and launches a collect process to gather healthand performance metrics. In order to optimize the monitoring on large environment, you cancustomize the discovery and the collect timeouts to specify how long the processes are expectedto run.

Page 48: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

48Configuring Monitor Settings

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

To customize the discovery and collect timeouts1. Create a new policy or edit an existing policy.

2. In the Add Monitoring Configuration panel, scroll down to the Optional Settings section.

Enabling/Disabling Volumes Monitoring

3. In the Discovery Timeout field, specify the number of minutes after which the discoveryshould be stopped. By default the discovery timeout is set to 6000 minutes. When thetimeout is reached for the first time, the Collection Status attribute of the Hitachi Disk ArrayMonitor Type is set to 2 (Failed) and triggers an alert, all subsequent timeout breaches willtrigger an alert on the Collection Status attribute of the instance of the Hitachi DeviceManager Monitor Type.

4. In the Collect Timeout field, specify the number of minutes after which the collect should bestopped. By default the collect timeout is set to 6000 minutes. When the timeout is reached,the Collection Status attribute of the instance of the Hitachi Device Manager Monitor Type isset to 2 (Failed) and triggers an alert.

5. Click OK to save your settings.

Page 49: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

49 Configuring Monitor Settings

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

Enabling the Debug ModeWhen you encounter an issue and wish to report it to Sentry Software, you will be asked toenable the Debug Mode and provide the debug output to the Sentry Software support team.

To enable the debug mode1. Create a new policy or edit an existing policy.

2. Click Add Monitoring Configuration panel and scroll down to the Advanced Settings section.

Enabling the Debug Mode

3. Select the Enable Debug Mode option. The solution will store debug information in a log file.By default debug files are stored in the %PATROL_HOME%\log folder.

4. In the Debug End Time field, enter the date and time at which the system must stop loggingdebug information. Required format: yyyy/mm/dd hh:mm:ss.

5. Click OK to save your settings.

For the debug mode to be enabled, the Enable Debug Mode must be checked and the Debug End Timemust be properly set to a date and time in the future.

Page 50: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

50Configuring Monitor Settings

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

Managing Advanced Configuration VariablesAdvanced configuration variables are used to manually set variables that are not availablethrough the TrueSight standard interface.

These variables should only be set when instructed so by Sentry Software Support.

List of available configuration variables

Variables DefaultValue

Description

collectionHubHeapSizeMax

1024 Maximum heap size in megabytes allocated to the Java Collection Hub.

collectionHubHeapSizeMin

None Minimum heap size in megabytes allocated to Java Collection Hub.

collectionHubOverrideJavaCommandLine

None Command line used by the monitoring solution to launch the JavaCollection Hub. This variable should only be set if instructed by SentrySupport.

defaultReinitializationOptions

None List of default options to be executed by TrueSight OperationsManagement - Hitachi Storage on reinitialization.

resetThresholds

resetThresholdManagementMode

resetAlertActions

resetOtherAlertSettings

resetDebugMode

resetRemovedPausedObjectList

resetReport

resetSecuritySettings

resetJavaSettings

Insert a colon “;” between the variable and its value: “resetThresholds;1”;and if you enter multiple variables, they need to be separated by acarriage return.Example: “resetThresholds;1” will display the remove thresholds optionselected by default in the Reinitialize KM wizard.

disableJRECheck 0 = JREvalidationtestsenabled

When set to 1, disable the validation tests of the JRE used by themonitoring solution to run Java code. This can be used to force the KM touse a non-Sun or non-Oracle JRE.

disablePslExecuteBugWorkaround

0 =activated

When set to ‘1’, deactivates the workaround in the monitoring solution fora bug in the PslExecute() PSL function.

Page 51: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

51 Configuring Monitor Settings

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

Variables DefaultValue

Description

If the product detects that the version of the PATROL Agent is affected bythe PslExecute() bug, it uses an alternate technique to createasynchronous threads with the event_trigger() function and the RemPslstandard event. The disablePslExecuteBugWorkaround variable disablesthis workaround.

forceClassicConfigMode

0 =disabled

When the product is used with BMC TrueSight Operations Management, allthe KM configuration menus are disabled in the PATROL Consoles. Toenable them, set the forceClassicConfigMode variable to 1.

javaPassword None Password associated to the javaUsername variable.

javaPath None Path to the folder containing the Java executable used by the CollectionHub. Path to the folder containing the Java executable used by theCollection Hub.

javaUsername None Username used to launch the Java Collection Hub.

pausedObjectList n/a List of the PATROL object path of the paused objects. (i.e. for which nocollection will be performed).

psCommand n/a Command used on UNIX/Linux systems to retrieve the list of the currentlyrunning processes.Note: This command is used for debug purpose.

refresh None To specify the refresh behavior to be adopted by TrueSight OperationsManagement - Hitachi Storage.

removedObjectList

n/a List of instances that have been removed from the monitoring environmentthrough the Remove KM Command.

startupDelay 0 second To specify the number of seconds that TrueSight Operations Management -Hitachi Storage will wait before starting its discovery. This variable maybe useful on fast booting computers where the Embbeded HitachiSMI-SProvider starts after the monitoring solution and triggers an alert.

To set a configuration variable1. Create a new policy or edit an existing policy.

2. Click Add Monitoring Configuration and scroll down to the Advanced Configuration Variablessection and click Add to open the Configuration Variables panel:

Adding a Configuration Variable

Page 52: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

52Configuring Monitor Settings

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

3. In the Configuration Variables panel, enter the name of the configuration variable and enterthe value to be set. Refer to the table above to learn about all the configuration variablesyou can use to perform operations you cannot complete with the console standard userinterface.

Configuring a Variable

4. Click OK to save your settings.

The Name field is case sensitive.

5. The configuration variable is then listed in the Additional Configuration Variable section:

List of Set Configuration Variables

To edit a configuration variable

1. Click the button next to the variable you wish to modify and click Edit.

Editing a Configuration Variable

Page 53: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

53 Configuring Monitor Settings

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

2. Change the variable value and click OK to save your settings.

To delete a configuration variable1. Click the button next to the variable you wish to remove and click Delete.

Deleting a Configuration Variable

2. Click OK to validate. The configuration variable is removed from the list.

Scheduling Automatic ReportsTrueSight Operations Management - Hitachi Storage can automatically produce text reports thatprovide detailed and valuable information about your monitored storage systems.

To schedule automatic reports1. Create a new policy or edit an existing policy.

2. Click Add Monitoring Configuration and scroll down to the Reporting section.

Scheduling automatic reports

3. In the Schedule section, indicate the time at which the report(s) must be generated.

4. Check the Activity report type to automatically generate the following reports:

Disk Array Activity: Reports on Read and Write Bytes for all monitored disk arrays

Controller Activity: Reports on Transfer Bytes for all monitored controllers

Fiber Port Activity: Reports on Transfer Bytes for all monitored fiber ports

Storage Pool Activity: Reports on Read and Write Bytes for all monitored storage pools

Page 54: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

54Configuring Monitor Settings

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

Volume Activity: Reports on Read and Write Bytes for all monitored volumes

5. Check LUNs Mapping Table to automatically generate a mapping table of LUNs to hosts. The.csv file generated for this report consists in the following comma-separated data: Array,Hostname, Host, WWN/IQN, LUN, FC Ports, Size and Status.

6. Click OK to save your settings.

The generated file(s) are time-stamped and stored in %PATROL_HOME%\log as csv files for thespecific time set through the History Retention Period attribute.

Updating a policy that set the scheduling options of a report purges the report configuration variablesand stops the report process.

The history retention period can be set f rom the PATROL Console or f rom the PATROL Agent using aconf iguration variable. The default collection (retention) period is one day. Whenever a stored attributevalue exceeds its retention period, it is automatically deleted from the attribute history f ile. Refer to BMCdocumentation for details.

Configuring Alert ActionsAlert Actions enable you to choose specific actions to be executed when a storage problem isdetected. Using alert actions, you can customize the way a storage problem notification isperformed.

Hitachi Storage Monitoring can be configured to run one, several, or all types of alert actionswhen an alert is triggered regarding the monitored storage system.

Page 55: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

55 Configuring Monitor Settings

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

To set the alert actions you want the solution to perform when aproblem occurs1. Create a new policy or edit an existing policy.

2. Click Add Monitoring Configuration and scroll down to the Global Alert Settings section.

Configuring Alert Actions

3. In the Events section, select the type of event you want the solution to trigger Upon aStorage Problem:

A Specific PATROL Event (Specific storage problem related to a monitored component)

A STD 41 PATROL Event (Standard 41 event)

No Event

These events are generated every time a threshold is exceeded. They contain a full Storage Health Reportdetailing the fault that has occurred.

4. Select the Enable Annotations option to make the solution annotate the attribute’s graphwith a comprehensive report of the problem.

5. Click OK to save your settings.

Page 56: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

Monitoring your StorageEnvironment

Page 57: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

57

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

The BMC TrueSight Operations Management platform, combined with the powerful monitoringfeatures of Hitachi Storage Monitoring, provides you with a visual representation of themonitored resources in your environment to give you a full picture of your SAN. The solutionproactively detects, automatically predicts, and resolves IT performance issues and sub-optimalconfigurations before users and services are negatively impacted. Integrated as a native modulefor BMC TrueSight Operations Management, Hitachi Storage Monitoring monitors the physicalaspects your entire Hitachi environment. It reports hardware failures and monitors keyperformance metrics. It helps you diagnose any availability issue in the SAN, and ensuresmaximum data protection by monitoring a wide range of critical components.

Viewing the Overall Activity of a Device

The BMC TrueSight Operations Management Monitoring menu gives you access to variousoptions for viewing your monitored environment: Applications, Devices, Events, Groups. Thischapter focuses on the Devices page that displays information about the Hitachi devices thatTrueSight Operations Management - Hitachi Storage monitors.

Log on to the BMC TrueSight Operations Management console and select Monitoring > Devices toaccess basic information for each Monitor associated with a monitored device.

Devices Page

The Devices page displays information about the devices that Hitachi Storage Monitoringmonitors and a view of the overall health of the system.

Page 58: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

58

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

To drill down and view a specific device details, click the device name or the events count.

Device name: Displays the Monitors tab in the Device Details page.

Events count: Displays the Events tab in the Device Details page.

Device Details

The Device Details page displays the device name, type, DNS name, IP address, and source name.The event status and severity matrix displays the number of events in each status and severity.

Device Monitors

This page displays all the monitors that are associated with the device.The action menu allowsyou to change and sort the view. In the tile view, you can show or hide the monitor type andsource name. In the Table View, you can expand the monitor rows to drill down into the devicecomponents.

Device Events

This page displays all the events that are associated with the device. By default, events ofCritical, Major, Minor, Warning, and Information severity and Open, Acknowledged, andAssigned status are displayed. To view events of a specific status and severity, click theappropriate event count in the events matrix.

Refer to the BMC documentation for detailed information about the BMC TrueSight OperationsManagementfeatures and options.

Page 59: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

59

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

Creating Consolidated Data Viewswith DashboardsBMC TrueSight Operations Management provides dashboards to create consolidated andcustomized views of your monitored IT environment. Dashboards are built from dashlettemplates. Once you have selected the dashlet that corresponds to the type of view you wish tocreate, you can access a specific type of data and present it graphically.

TrueSight Operations Management - Hitachi Storage monitors availability, capacity, andperformance for Hitachi disk arrays. It makes this data available to you through different dashletsfor you to create a clear view of the performance and status of your storage environment withina private or shared dashboard. The product leverages the BMC TrueSight OperationsManagement unified features and capabilities to offer you a deep visibility into over 200 keymetrics.

When a dashlet in the dashboard identif ies a problem, it also acts as an access point to investigate andtroubleshoot the root cause.

This chapter explains how to create consolidated views for some of the most critical elements ofyour Hitachi environment. Dashboards report on critical aspects of your Hitachi storage systems,and consolidate and normalize information from a variety of sources. While saving youconsiderable time and effort, a unified view can help you rapidly and proactively detect poorstorage performance and hardware failures.

TipOnce you have created a dashboard, you may want to use its settings to create anotherdashboard f or a dif f erent device. To do so, copy the dashboard f rom the Dashboards page:1. Click My Dashboards or Shared Dashboards.

2. In the action menu to the lef t of the dashboard name, select Copy Dashboard.

3. The new dashboard appears in the My Dashboards list as Copy of <DashboardName>.

The following topics describe how to create dashboards for:

Detecting Unbalanced Workload Distribution on Controllers

Identifying Busiest Volumes

Reporting Disk Space Consumption

Use cases were performed with BMC TrueSight Operations Management v.10.1.

Page 60: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

60Creating Consolidated Data Views withDashboards

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

Detecting Unbalanced Workload Distributionon ControllersA storage controller manages the flow of information between the server and the data, assigningtwo paths, in case one of the paths fails or is overloaded. For the best levels of performance andavailability, every layer of technology must be balanced.

To detect an unbalanced workload distribution between two controllers, you will need to createa simple two-column dashboard. Dashboards allow you to gather specific types of data anddisplay them in a consolidated graphical format. For detailed information about dashboardsoptions and features, refer to the BMC documentation.

Page 61: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

61 Creating Consolidated Data Views withDashboards

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

To Detect Unbalanced Workload Distribution Across Controllers1. Login to your BMC TrueSight Operations Management console.

2. Select Dashboards from the navigation pane.

3. In the Dashboards page, click Add Dashboard or select Add Dashboard from the dashboard

action menu .

4. Enter a Title for your dashboard and configure a Global Filter, if needed.

5. Click Add Dashlet to open the dashlet library for the first column of the row.

6. From the dashlet library, select the Device Performance template, and then click Close.

7. Select Configure Dashlet by clicking the button.

8. In the panel of input fields and options that opens below the dashboard, enter a Title for thedashlet and specify a Refresh Rate (default is 5 minutes).

9. Select the Hitachi storage device for which you to compare workload distribution.

10. Select the Read Cache Hit Ratio and the Transfer Byte Rate parameters for the first controller,and click Apply.

Page 62: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

62Creating Consolidated Data Views withDashboards

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

Tip

To quickly retrieve a component or a parameter, enter its name in the Search Parameters f ieldand click Search.

11. Repeat this operation in the next column of the dashboard for another controller and click Save.

12. The dashboard is completed and shows the Read Cache Hit Ratio and the Transfer Byte Ratefor both controllers.

For example, if the throughput on one controller is significantly higher than the other one, itindicates that one on the controllers may constitute a bottleneck for the subsystem that could bealleviated by better sharing the load between the controllers.It is recommended to pay close attention to which logical drive is handled by which controller,depending on the activity of this logical drives to be able to reallocates controller to drive I/Oactivity so that neither controller is overloaded.

Page 63: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

63 Creating Consolidated Data Views withDashboards

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

Identifying Busiest VolumesMonitoring volumes to find out if the amount of data processed is dangerously growing close tothe volume's limit will help you not being caught short of space without warning.

To identify the volumes that generate the most traffic, you will need to create a simple one-rowdashboard. Dashboards allow you to gather specific types of data and display them in aconsolidated graphical format. For detailed information about dashboards options and features,refer to the BMC documentation.

Page 64: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

64Creating Consolidated Data Views withDashboards

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

To Identify Busiest Volumes1. Login to your BMC TrueSight Operations Management console.

2. Select Dashboards from the navigation pane.

3. In the Dashboards page, click Add Dashboard or select Add Dashboard from the dashboard

action menu .

4. Enter a Title for your dashboard and configure a Global Filter, if needed.

5. Click Add Dashlet to open the dashlet library for the first column of the row.

6. From the dashlet library, select the Device Performance template, and then click Close.

7. Select Configure Dashlet by clicking the button.

8. In the panel of input fields and options that opens below the dashboard, enter a Title for thedashlet and specify a Refresh Rate (default is 5 minutes).

9. Select the Hitachi storage device for which you want to compare processors utilization.

10. Select the Read Operation Rate and the Write Operation Rate parameters for the firstvolume, and click Apply.

Page 65: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

65 Creating Consolidated Data Views withDashboards

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

Tip

To quickly retrieve a component or a parameter, enter its name in the Search Parameters f ieldand click Search.

11. Repeat this operation in the next column of the dashboard for other volumes and click Save.

12. The dashboard is completed and shows the Read Operation Rate and the Write OperationRate for all the selected volumes.

Page 66: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

66Creating Consolidated Data Views withDashboards

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

Reporting Disk Space ConsumptionMaking sure that a storage system has enough remaining disk space available is critical forseveral reasons:

SAN administrators want to make sure to be able to provision disk space for new serverswhen requested, as quickly as possible.

The storage system itself may need additional disk space for specific features to workproperly, like automatic snapshots, mirroring, etc.

If thin provisioning is used, the remaining disk space becomes dramatically critical since theinability to allocate additional space to a volume when requested by the subscriber host willlead to catastrophic data loss and corruption.

The disk space used is permanently monitored for each storage pool. The Subscribed Capacityparameter of a storage pool represents the amount of disk space that has been made available tothe subscriber hosts, or in other words, the amount of disk space that is seen by the serversconnected to the storage system.

The Consumed Capacity parameter of a storage pool represents the actual space usage in thestorage pool. For “thin” pools (when thin provisioning is enabled on the storage system), thisvalue is normally lower than the Subscribed Capacity, as it is the main purpose of thinprovisioning. For traditional pools, the Consumed Capacity has the same value as the SubscribedCapacity, as the entirety of the subscribed disk space is fully allocated in the storage pool.

The Consumed Capacity Percentage parameter is the most critical one, even for non-thin storagepools, as a storage pool usage nearing 100% means that SAN administrators will not be able tocreate new volumes in the storage pool. By default, no alarm or warning threshold is set on thisparameter as the fullness of a storage pool may be a normal situation.

To determine the actual disk space consumption for a storage system, you will need to create asimple three-column dashboard. Dashboards allow you to gather specific types of data anddisplay them in a consolidated graphical format. For detailed information about dashboardsoptions and features, refer to the BMC documentation.

Page 67: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

67 Creating Consolidated Data Views withDashboards

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

To Report on Disk Space Consumption1. Login to your BMC TrueSight Operations Management console.

2. Select Dashboards from the navigation pane.

3. In the Dashboards page, click Add Dashboard or select Add Dashboard from the dashboard

action menu .

4. Enter a Title for your dashboard and configure a Global Filter, if needed.

5. Click Add Dashlet to open the dashlet library for the first column of the row.

6. From the dashlet library, select the Device Performance template, and then click Close.

7. Select Configure Dashlet by clicking the button.

8. In the panel of input fields and options that opens below the dashboard, enter a Title for thedashlet and specify a Refresh Rate (default is 5 minutes).

9. Select the Hitachi storage device for which you want to compare processors utilization.

10. Select the Subscribed Capacity parameter for a storage pool, and click Apply.

Page 68: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

68Creating Consolidated Data Views withDashboards

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

Tip

To quickly retrieve a component or a parameter, enter its name inthe Search Parameters field and click Search.

11. Repeat this operation in the next column of the dashboard for the Consumed Capacityparameter and click Apply.

12. Finally, in the third column of the dashboard, select the Consumed Capacity Percentageparameter and click Save.

13. The dashboard is completed and shows the disk space consumption for the selected storagepools.

Page 69: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

Reference Guide

Page 70: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

70

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

Introduction

This chapter provides statistical information about resources, operating status, and performancesmanaged by the TrueSight Operations Management - Hitachi Storage. It contains tablesdescribing the attributes used in the KM, grouped by Monitor Types, and provides a briefdescription of each attribute and its default settings.

Monitor Types

Hitachi Disk Array

Hitachi Controller

Hitachi Fiber Port

Hitachi Device Manager

Hitachi Managed Array

Hitachi Storage Pool

Hitachi Volume

Baselines and Key Performance Indicators

Some attributes are identified by default as Key Performance Indicators (KPIs) and thereforeautomatically included in the base lining calculation. To learn more about auto baselining andKPIs, please refer to the "Managing Baselines and Key Performance Indicators" chapter.

In this guide, attributes flagged as KPIs and included by default in the baseline calculation

process are respectively identified by the following icon: KPI

Page 71: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

71

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

Hitachi Disk ArrayAttributes

Name Description Units Default AlertConditions

Attribute Type

CollectionStatus

Status of the collection. {0= OK; 1 =Degraded; 2=Failed}

Warning = 1Alarm = 2

CollectionStatus

AvailableCapacity

Total capacity less consumed capacity (Theconsumed capacity corresponds to theconsumed capacity of unallocated volumeswith DP pool + consumed capacity ofallocated volumes).

Terabytes(TB)

None Statistics

Operation Rate Amount of operations transmitted persecond.

Operations/s

None Statistics

Port Count Number of ports on the disk array. Ports None Statistics

Status Status of the array. {0= OK; 1 =Degraded; 2=Failed}:

Warning = 1Alarm = 2

Availability

SubscribedCapacity

The sum of the host visible capacity of themapped volumes.

Terabytes(TB)

None Statistics

Transfer Byte

Rate

Count of data transferred per second. Megabytesper second(MB/s)

None Statistics

For detailed information about KPI, see Managing Baselines and Key Performance Indicators.

Page 72: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

72Hitachi Disk Array

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

Hitachi ControllerAttributes

Name Description Units Default AlertConditions

Attribute Type

Read Cache HitRatio

Percentage of read requests that aresuccessfully served by a cache.

Percentage(%)

None Statistics

Transfer Byte

Rate

Count of data transferred per second. Megabytesper second(MB/s)

None Statistics

Write Cache HitRatio

Percentage of write requests that aresuccessfully served by a cache.

Percentage(%)

None Statistics

For detailed information about KPI, see Managing Baselines and Key Performance Indicators.

Page 73: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

73 Hitachi Controller

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

Hitachi Fiber PortAttributes

Name Description Units Default AlertConditions

Attribute Type

BandwidthUtilization

Amount of bandwidth currently in use bythe FC port.

Percentage(%)

None Statistics

Operation Rate Amount of operations transmitted persecond.

Operations/s

None Statistics

Transfer Byte

Rate

Count of data transferred per second. Megabytesper second(MB/s)

None Statistics

For detailed information about KPI, see Managing Baselines and Key Performance Indicators.

Page 74: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

74Hitachi Fiber Port

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

Hitachi Device ManagerAttributes

Name Description Units Default AlertConditions

Attribute Type

CollectionStatus

Status of the collection. {0= OK; 1 =Degraded; 2=Failed}

Warning = 1Alarm = 2

CollectionStatus

Page 75: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

75 Hitachi Device Manager

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

Hitachi Managed ArrayAttributes

Name Description Units Default AlertConditions

Attribute Type

Refresh Rate SMI-S Provider refresh rate. minutes None Statistics

Statistics Indicates whether the statistics are enabledor not.

{0 =Enabled;1 =Disabled}

Alarm = 1 Statistics

Page 76: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

76Hitachi Managed Array

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

Hitachi Storage PoolAttributes

Name Description Unit Default AlertConditions

Attribute Type

ConsumedCapacity

Total size of the space actually allocatedor reserved.

Terabytes(TB)

None Statistics

ConsumedCapacityPercentage

Percentage of the storage pool that isactually allocated or reserved.

Percentage (%)

Warning ≥80%Alarm ≥ 90%

Statistics

OversubscriptionSituation

This attribute reports an oversubscriptionsituation, that is when:

1.The storage pool is configured for thinprovisioning (“thin storage pool”)

2.the SubscribedCapacityPercentageparameter is greater than 100%, and

3.the ConsumedCapacityPercentageparameter is greater than 75%

Such situation is highly critical becausethe inability to allocate additional spaceto a volume when requested by thesubscriber host will lead to catastrophicdata loss and corruption.

{0= No; 1 =Yes}

Alarm = 1 Statistics

SubscribedCapacity

Total host visible capacity. Terabytes(TB)

None Statistics

SubscribedCapacityPercentage

Percentage of the storage pool that issubscribed.

Note: This parameter can exceed 100 % forthin provisioned storage pools.

Percentage (%)

Warning ≥80%Alarm ≥ 90%

Statistics

Transfer ByteRate

Count of data transferred per second. Megabytespersecond(MB/s)

None Statistics

Page 77: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

77 Hitachi Storage Pool

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

Hitachi VolumeAttributes

Name Description Unit Default AlertConditions

Attribute Type

ConsumedCapacity

Total size of the space actually allocated orreserved.

Gigabytes(GB)

None Statistics

ConsumedCapacityPercentage

Percentage of the storage pool that isactually allocated or reserved.

Percentage (%)

None Statistics

Host VisibleCapacity

Amount of space on the disk that isassigned to bound LUNs.

Gigabytes(GB)

None Statistics

Read Cache HitRatio

Percentage of read requests that aresuccessfully served by a cache.

Percentage (%)

None Statistics

Read OperationPercentage

Percentage of read operations. Percentage (%)

None Statistics

Read OperationRate

Count of operations read per second. Operation/s

None Statistics

Time Since LastActivity

Number of days since any activity occurredon the volume.

Days None Statistics

Transfer ByteRate

Count of data transferred per second. Megabytespersecond(MB/s)

None Statistics

Write Cache HitRatio

Percentage of write requests that aresuccessfully served by a cache.

Percentage (%)

None Statistics

WriteOperationPercentage

Percentage of write operations. Percentage (%)

None Statistics

WriteOperation Rate

Count of operations written per second. Operation/s

None Statistics

Page 78: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

78Hitachi Volume

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

Managing Baselines and KeyPerformance IndicatorsTo detect abnormalities on the monitored environment, BMC TrueSight Operations Managementcalculates baselines per attribute based on values collected over a specified period of time todetermine a normal operating range. When the collected values for these parameters are out ofrange, an alert is triggered. Some attributes are identified by default as Key Performance

Indicators (identified with the icon) and automatically included in the base lining calculation.

Managing baselines

The baseline is the expected normal operating range for an attribute of a monitor. There are twobaselines: Baseline High and Baseline Low. Baseline High represents the point at which 95% ofthe weighted average of the historical values fall below this value for the selected time period; Baseline Low represents the point at which 90% of the weighted average of historical values forthe selected time period fall above this line.

Baselines are generated for KPI attributes that have an active abnormality thresholds.

Managing Key Performance Indicators

Starting from v9.5 of BPPM, attributes that have not been initially designated in the KM as KeyPerformance Indicators (KPIs) cannot be flagged as KPIs from BPPM/TrueSight. Although enablingbaseline is possible through the Options > Administration > Intelligent Event Thresholds featureavailable in the Infrastructure Management Server operator console, BMC does not recommenddoing it.

For more information, refer to the BMC TrueSight Operations Management documentation available f romdocs.bmc.com.

Page 79: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

Troubleshooting ConnectivityIssues

Page 80: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

80

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

TrueSight Operations Management - Hitachi Storage leverages the Hitachi Device Manager .Because some connectivity issues may exist and cause TrueSight Operations Management -Hitachi Storage to fail, it is highly recommended to test the connection to the Hitachi DeviceManager before contacting the Sentry Support Team.

To troubleshoot connectivity issues:

1. Download the connection tool required from the Sentry Software Website. Please note thatthe connection tool requires Java v1.6 or higher.

2. Run the command java -jar troubleShooting-Tools-for-Hitachi-Device-Manager-<version>.jarto launch the connection tool.

3. Enter the information required to connect to the system and click Test Connection.

4. Wait for the test to complete. If a connectivity issue is detected, an error message willappear. In this case, the issue encountered has nothing to do with Hitachi StorageMonitoring. Check your configuration to diagnose the source of the issue.

5. Click Save As to export the connection test results into a txt file. You can then send thisinformation to the Sentry Support Team.

Page 81: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

81

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

Index

- A -Abnormalities 78

Advanced Configuration Variables

collectionHubHeapSizeMax 50

collectionHubHeapSizeMin 50

collectionHubOverrideJavaCommandLine 50

Configuration Variables 50

defaultReinitializationOptions 50

disableJRECheck 50

disablePslExecuteBugWorkaround 50

forceClassicConfigMode 50

javaPassword 50

javaPath 50

javaUsername 50

pausedObjectList 50

psCommand 50

refresh 50

removedObjectList 50

retryDiscoveryAfterNTimes 50

startupDelay 50Advanced Settings 49

Annotate

Enable 54

Graph 54Architecture 9

Attributes 70

Available Capacity 71

Bandwidth Utilization 73

Collection Status 71, 74

Consumed Capacity 76, 77

Consumed Capacity Percentage 76, 77

Host Visible Capacity 77

Operation Rate 71, 73

Oversubscription Situation 76

Port Count 71

Read Cache Hit Ratio 72, 77

Read Operation Percentage 77

Read Operation Rate 77

Reresh Rate 75

Statistics 75

Status 71

Subscribed Capacity 71, 76

Subscribed Capacity Percentage 76

Time Since Last Activity 77

Tranfer Byte Rate 71, 73

Transfer Byte Rate 72, 76, 77

Write Cache Hit Ratio 72, 77

Write Operation Percentage 77

Write Operation Rate 77Automatic Reporting 53

- B -Baselines

BMC ProactiveNet Performance Management 78

Generation 78

Manage 78

Requirements 78BMC ProactiveNet Performance Management

Abnormalities 78

Baselines 78

Key Performance Indicators 78

KPI 78Busiest Volumes

Identify 63

- C -Changes and Improvements 7

Collect

Timeout 47Component Installation package

creating 37

downloading 38Configuration Variables

Delete 50

Edit 50

Manage 50Configure

Alert Actions 54

Annotations 54

Hitachi Device Manager 23Connectivity

Issues 80Consumed Capacity 66

Consumed Capacity Percentage 66

Controller

Workload distribution 60

Page 82: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

82

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

- D -Dashboards 59

Debug Mode

Debug End Time 49

Enabling 49Device

Details 57

Events 57

Monitors 57

Overall Activity 57

Page 57Device Manager Agent

Install 16Discovery

Customize 44

Timeout 47Disk Space Consumption

Report 66Downloading 38

- E -Embedded SMI-S Provider 40

Enable

Statistics 13, 33Enabling

Debug Mode 49Enabling Statistics 31

Events 54

- F -Features 9

Fixed Issues 7

- G -Generate

Baselines 78Global Alert Settings 54

Goals 9

Graph

Annotate 54

- H -Hitachi AMS 13

Hitachi Command Suite

Install 13Hitachi Device Manager 12, 13, 40

Configure 23

Install 13

Pre-requisites 13Hitachi HUS 13

Hitachi Storage 40

Hitachi Storage Navigator Modular 31

Hitachi USP 13

Hitachi VSP 33

HSNM 31

- I -Importing the Monitoring Solution 36

Install

Device Manager Agent 16

Hitachi Command Suite 13

Hitachi Device Manager 13Installing 38

Installing the Monitoring Solution 35

Intervals

Customize 44

Discovery 44

Polling 44Issues

Connectivity 80

Troubleshooting 80

- K -Key Concepts 9

Key Performance Indicators

BMC ProactiveNet Performance Management 78

Manage 78KPI

BMC ProactiveNet Performance Management 78

Manage 78

Page 83: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

83

True

Sigh

t O

pera

tion

s M

anag

em

ent

- H

itac

hi S

tora

ge V

ersi

on 1

.5.0

0

- L -LUNs Mapping Table 53

- M -Manage

Baselines 78

Key Performance Indicators 78

KPI 78Monitor

Storage Environment 57Monitor Settings

configuring 40

global settings 40Monitor Types 70

add 40

Hitachi Controller 72

Hitachi Device Manager 74

Hitachi Disk Array 71

Hitachi Fiber Port 73

Hitachi Managed Array 75

Hitachi Storage Pool 76

Hitachi Volume 77

- O -Optional Settings 44, 47

- P -Package 37, 38

PATROL

Agent 12

Console 12PATROL Event

Specific 54

Standard 54

STD_41 54Policy

create 40

edit 40Polling

Customize 44Prerequisite 12

Prerequisites 13

Pre-requisites 13

- R -Read Cache Hit Ratio 60

Read Operation Rate 63

Reference Guide 70

Reporting 53

Reports

Controller Activity 53

Disk Array Activity 53

Fiber Port Activity 53

Storage Pool Activity 53

Volume Activity 53Role 12, 33

- S -SMI-S Provider 12

Embedded 33

Start 33Start

SMI-S Provider 33Statistics 12, 31

Enable 13, 33Storage administrator view only 33

Storage Environment

Monitoring 57Subscribed Capacity 66

- T -Timeouts

Collect 47

Discovery 47Transfer Byte Rate 60

Troubleshooting

Connectivity Issues 80

- U -User 33

- W -Write Operation Rate 63

Page 84: TrueSight Operations Management - Hitachi … Operations Management - Hitachi Storage provides current and historical information ... Refer to Monitoring Hitachi VSP Gxxxx Series Systems

About Sentry Software™Sentry Software, a strategic Technology Alliance Partner of BMC Software, providescomprehensive multi-platform monitoring solutions that enable management of thehardware and software aspects of all servers and SANs and covering up to 100 % ofcustom applications within the BMC TrueSight environment. Sentry Software alsodevelops adapters for BMC Atrium Orchestrator that enables IT administrators toautomate the execution of common requests and tasks that occur in the daily course ofIT operations. Combined with BMC’s servers and network automation tools, theadapters allow IT administrators to implement provisioning and decommissioningworkflows that cover all layers of their IT infrastructure. Finally, Sentry Software designsconnectors that bring storage capacity metrics into BMC TrueSight Capacity Optimizationto ensure IT administrators that their storage infrastructure is properly sized for theircurrent and future needs.

Like us on Facebook:facebook.com/sentrysoftware

Follow us on Twitter:

twitter.com/sentrysoftware

LEARN MORE

To learn more about our solutions, please visit :www.sentrysoftware.com/solutions

© BMC Software, Inc. All rights reserved.

ABOUT MARKETZONE DIRECT PRODUCTS

The BMC MarketZone Directprogram sells and supportsthird-party products thatcomplement and/or augment BMCsolutions. MarketZone Directproducts are available under BMClicense and support terms.

About BMC Software™BMC Software helps leading companies around the world put technology at the forefrontof business transformation, improving the delivery and consumption of digital services.From mainframe to cloud to mobile, BMC delivers innovative IT management solutionsthat have enabled more than 20,000 customers to leverage complex technology intoextraordinary business performance—increasing their agility and exceeding anythingthey previously thought possible. For more information about BMC Software, visit

www.bmc.com.

Bus ines s thrives when IT runs s marter,fas ter and s tronger. That’s why the mos tdemanding IT organizations in the worldrely on BMC Software acros s dis tributed,mainframe, virtual and cloudenvironments . Recognized as the leader inBus ines s Service Management, BMC offersa comprehens ive approach and unifiedplatform that helps IT organizations cutcos t , reduce ris k and drive bus ines sprofit . For the four fis cal quarters endedSeptember 30,2011, BMC revenue wasapproximately $2.2 billion.

BUSINESS RUNS ON I.T .

I.T . RUNS ON BMC SOFT WARE