MOP-RTN Family– IDU 605 2B:
– maximum capacity 16 × E1 , Support 1+1configure
T2000 Web LCT – Installation Guide
• Prerequisite: Windows XP Professional SP2 or Windows 2003 Server standard SP1/SP2 must be installed.
• Procedure
– Step 1 Uncompress the installation package or Insert the installation CD, and run the setup.exe file. Click Next.
T2000 Web LCT – Installation Guide
– Step 2 Select I accept the terms of the license agreement and click Next.
T2000 Web LCT – Installation Guide– Step 3 Click Next.
T2000 Web LCT – Installation Guide
– Step 4 Click Install and the Setup Status dialog box is displayed. After the T2000 Web
LCT is installed, the Installation Complete dialog box is displayed.
T2000 Web LCT – Installation Guide
Step 5 Click Finish.
T2000 Web LCT – Installation Guide
Checking the Installation
After you install the T2000 Web LCT, you need to check the correctness
of installation. Check directories and files as follows:
• The T2000 Web LCT installation directory.
– By default is C:\Web_LCT.
• The installation directory of the jre software.
– By default is C:\Web_LCT\jre.
T2000 Web LCT – Installation Guide
• The installation directory of the Tomcat software. – By default is C:\Web_LCT\Tomcat .
• Check the shortcut icon. – On the Windows desktop, the Start Web LCT and the Stop Web LCT shortcut
icons are displayed. – Choose Start > Programs. The iManager T2000 Web LCT group contains the
Start Web LCT and the Stop Web LCT shortcut icons.
T2000 Web LCT – Connecting to NEs• To use the T2000 Web LCT to configure and manage NEs, you need to connect
the T2000 Web LCT to NEs with an Ethernet cable or a serial port.
• Procedure
– By using a network cable
1. Connect a network cable to the computer where the
T2000 Web LCT resides.
2. Route the network cable to the equipment side and
connect the RJ-45 connector of the network cable to the
network management interface on the front panel of
the equipment.
Web LCT Configuration – Logging In to an NE
Step1 Double-click the T2000 Web LCT shortcut icon on the desktop to launch the T2000 Web LCT.
Step2 The User Login screen is displayed. Enter the user name and password. Click Login.(UN:admin,PW:T2000)
Managing NEs – Creating an NE Create an NE in one of the following two ways.
1. Click NE Search and specify the search criteria. Select the NE to be added to create a new NE.
Managing NEs – Creating an NE
2. Create an NE directly. Click the “Add NE” and Enter
the information of the NE and create the NE.
Managing NEs – Logging In to an NE Step 1: In the NE List, select the target NE
and click NE Login.Then,
The IE displays the NE Login dialog box, UN is default:lct,PW:password
After login go to NE explorer
Selected NE slot layout Page will appear
In the NE Explorer, choose Configuration > NE Attribute from the Function Tree.
Managing NEs – Modifying the NE ID
Managing NEs – Modifying the NE IP Select the NE from the Object Tree in the NE Explore. Choose
Communication > Communication Parameters from the Function Tree.
Set the IP.
Click Apply.
Managing NEs – Configuring Logical Boards Click the Slot Layout tab and click Add Logical Boards. Based on the
slot layout, the NE automatically configures the logical boards that are required but still not be configured for certain physical boards. (NOT Applicable for RTN605)
Change the NE time by Synchronization with NM
Managing NEs –Synchronizing the NE Time
Select the NE from the Object Tree in the NE Explore. Choose Configuration > NE Time Synchronization from the Function Tree.
After the synchronization mode and relevant parameters are set, click Apply.
Set the Synchronization Starting Time and click Apply.
How to configure the parameters of IF/ODU setting???.. 1.Select Link configuration in Configuration menu form function tree 2.Select the work mode of IF0 as per settings, give Link ID,TX frequency,Tx power,T/R spacing(Note: Link ID should be Same for the Opposite NE) 3. Click apply.
Important parameters,Link RSL,Tx freq,Txpower, Link ID???
To be given
How to check alarms??? Select alarm in function tree, go to browse alarms.
How to check E1 loop& break?Select PH-1--> configuration-->PDH interface, select the particular port for testing Loop configuration, then give apply.
1.Concept of Loopback!!!!
2.Concept of Loopback!!!!
How to clear TU Alarms?? Go to PH-1-->Alarm --> Alarm suppresion.Select the unused port T_ALOS as suppressed, then click Apply.
Select NE list icon to switch over the page NE List
NE LIST
Log out the NE.
Logout