4
Type 330/335/340/345 Series Instrument Air Filter Regulator & Regulator Type-330 Filter Regulator | Type-335 NACE Filter Regulator Type-340 Regulator | Type 345 Filter The Type 330/335/340/345 Series of Instrument Air Filter Regulators and Regulators are designed to provide clean, accurate air pressure to instruments, valves, and other automatic control equipment in a lightweight, compact housing. These quality instruments are constructed of durable materials that will provide long lasting performance in industrial environments. Type 330 Filter Regulator Designed for use in systems that require clean, accurate instrument air, the Type 330 provides pressure regulation and filtration in an integral compact package. Available in ¼" NPT porting for normal operation and ½" NPT porting for high flow capacity requirements. Type 330 Filter Regulator with Automatic Drain Condensate waste liquid is automatically flushed out when a change in air flow occurs or when the supply pressure is reduced. The low maintenance Automatic Drain helps prolong the life of the regulator and filter by preventing corrosion on the bottom of regulator and reducing the load of the filter. Type 335 NACE Filter Regulator Materials in the Type 335 meet NACE MR-0175 requirements (available in 1/4" only) Type 340 Regulator Designed to provide accurate, constant control under variable flow rates and supply pressures. Compact and lightweight housing allows this unit to be mounted in applications where space is limited. Its durable construction withstands long term installation in harsh environments. Type 345 Filter The Type 345 Filter unit is a 40-micron depth filter that removes dirt, moisture and other particles from air and gas lines. Robustly constructed of die-cast aluminum with a baked epoxy finish, this unit stands up in corrosive operating conditions. This filter is an economical alternative for air supply line applications that don't require a pressure reducing regulator. Available in 1/4" and 1/2" NPT porting, manual and automatic drain. Optional 5 micron filter. Type-330 1/2" Port Autodrain Type-330 1/2" Port Type-345 1/2" Port Type-330 1/4" Port Type-335 1/4" NPT Type-340 1/2" Port Type-340 1/4" Port

Type 330/335/340/345 Series - ControlAir · Type 345 Filter The Type 345 Filter unit is a 40-micron depth Glter that removes dirt, moisture and other particles from air and gas lines

  • Upload
    others

  • View
    7

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Type 330/335/340/345 Series - ControlAir · Type 345 Filter The Type 345 Filter unit is a 40-micron depth Glter that removes dirt, moisture and other particles from air and gas lines

Type 330/335/340/345 SeriesInstrument Air Filter Regulator & RegulatorType-330 Filter Regulator | Type-335 NACE Filter RegulatorType-340 Regulator | Type 345 Filter

The Type 330/335/340/345 Series of Instrument Air FilterRegulators and Regulators are designed to provide clean,accurate air pressure to instruments, valves, and otherautomatic control equipment in a lightweight, compacthousing. These quality instruments are constructed ofdurable materials that will provide long lasting performancein industrial environments.

Type 330 Filter RegulatorDesigned for use in systems that require clean, accurate instrumentair, the Type 330 provides pressure regulation and filtration in anintegral compact package. Available in ¼" NPT porting for normaloperation and ½" NPT porting for high flow capacity requirements.

Type 330 Filter Regulator with Automatic DrainCondensate waste liquid is automaticallyflushed out when a change in air flow occurs orwhen the supply pressure is reduced. The lowmaintenance Automatic Drain helps prolong thelife of the regulator and filter by preventingcorrosion on the bottom of regulator andreducing the load of the filter.

Type 335 NACE Filter RegulatorMaterials in the Type 335 meet NACE MR-0175 requirements (available in 1/4" only)

Type 340 RegulatorDesigned to provide accurate, constant controlunder variable flow rates and supply pressures.Compact and lightweight housing allows thisunit to be mounted in applications where spaceis limited. Its durable construction withstandslong term installation in harsh environments.

Type 345 FilterThe Type 345 Filter unit is a 40-micron depth filter thatremoves dirt, moisture and other particles from air and gaslines. Robustly constructed of die-cast aluminum with a bakedepoxy finish, this unit stands up in corrosive operatingconditions. This filter is an economical alternative for airsupply line applications that don't require a pressure reducingregulator. Available in 1/4" and 1/2" NPT porting, manual andautomatic drain. Optional 5 micron filter.

Type-330 1/2" Port Autodrain

Type-3301/2" Port

Type-3451/2" Port

Type-330 1/4" PortType-335 1/4" NPT

Type-340 1/2" Port

Type-340 1/4" Port

Page 2: Type 330/335/340/345 Series - ControlAir · Type 345 Filter The Type 345 Filter unit is a 40-micron depth Glter that removes dirt, moisture and other particles from air and gas lines

Type 330/335/340/345 Series Rugged and reliable instrument a OU

TPUT

PRE

SSUR

E, p

sig

(BAR

)

FLOW CURVES: Type 330/340: 1/4” NPT Units

0 5 10 15 20 25 30 35 (0) (142) (283) (425) (566) (708) (849) (991)

OUTP

UT P

RESS

URE,

psi

g (B

AR)

FLOW, scfm (Nl/min)

FLOW CURVES: Type 330/340: 1/2” NPT Units

0 20 40 60 80 100 120 140 160 180 200 (0) (566) (1,132) (1,698) (2,264) (2,830) (3,396) (3,962) (4,528) (5,094) (5,660)

Range 0-120 psig (0-8.3 BAR); 150 psig (10 BAR) supply

Range 0-60 psig (0-4.1 BAR); 100 psig (6.9 BAR) supply

Range 0-30 psig (0-2.1 BAR); 100 psig (6.9 BAR) supply

FLOW, scfm (Nl/min)

Range 0-120 psig (0-8.3 BAR); 150 psig (10 BAR) supply

Range 0-60 psig (0-4.1 BAR); 100 psig (6.9 BAR) supply

Range 0-30 psig (0-2.1 BAR); 100 psig (6.9 BAR) supply

90 (6.2) 80 (5.5) 70 (4.8) 60 (4.1) 50 (3.5) 40 (2.8) 30 (2.1) 20 (1.4) 10 (.69) 0 (0.0) OU

TPUT

PRE

SSUR

E, p

sig

(BAR

)

FLOW CURVES: Type 345: 1/4” NPT Units

0 10 20 30 40 50 60 70 80 90 100 0 (283) (566) (849) (1,132) (1,415) (1,698) (1,981) (2,264) (2,547) (2,830)

FLOW, scfm (Nl/min)

OUTP

UT P

RESS

URE,

psi

g (B

AR)

FLOW, scfm (Nl/min)

FLOW CURVES: Type 345: 1/2” NPT Units

0 20 40 60 80 100 120 140 160 180 200 (0) (566) (1,132) (1,698) (2,264) (2,830) (3,396) (3,962) (4,528) (5,094) (5,660)

160 (11)

140 (9.7)

120 (8.3)

100 (6.9)

80 (5.5)

60 (4.1)

40 (2.8)

20 (1.4)

0 (0.0)

160 (11)

140 (9.7)

120 (8.3)

100 (6.9)

80 (5.5)

60 (4.1)

40 (2.8)

20 (1.4)

0 (0.0)

90 (6.2) 80 (5.5) 70 (4.8) 60 (4.1) 50 (3.5) 40 (2.8) 30 (2.1) 20 (1.4) 10 (.69) 0 (0.0)

Specifications Type 330 Type 335 Type 340 Type 345 In/Out Port Size 1/4" NPT 1/2" NPT 1/4" NPT 1/4" NPT 1/2" NPT 1/4" NPT 1/2" NPT (Gauge Ports 1/4 NPT) Output Ranges 0-30 psig (0-2 bar) 0-60 psig 0-30 psig (0-2 bar) 0-30 psig (0-2 bar) 0-60 psig N/A (0-4 bar) 0-120 psig (0-8 bar) 0-60 psig (0-4 bar) (0-4 bar) 0-120 psig (0-8 bar) 0-100 psig (0-7 bar) Maximum Supply Manual drain: 250 psig (17 bar) 250 psig (17 bar) 250 psig (17 bar) Manual drain: 250 psig (17 bar) Pressure Auto drain: 150 psig (10 bar) Auto drain: 150 psig (10 bar) Mounting Pipe, bracket or through body direct Filter 40 micron (5 micron optional) None 40 micron (5 micron optional) Cv Values 0.5 at 150 psig 2.5 at 150 psig 0.5 at 150 psig 0.5 at 150 psig 2.5 at 150 psig 0.5 at 150 psig 2.5 at 150 psig supply and supply and supply and 80 supply and 80 supply and 80 supply and 80 supply and 80 80 psig setpoint 80 psig setpoint psig setpoint psig setpoint psig setpoint psig setpoint psig setpoint Exhaust Capacity 0.1 scfm (2.83 Nl/min) with downstream pressure 5 psig (0.3 bar) above set point N/A Sensitivity 1" of water N/A Air Consumption Less than 5 scfh (2.5 Nl/min) N/A Effect of Supply Less than 0.25 Less than 0.5 Less than 0.25 Less than 0.25 Less than 0.5 N/A Pressure Variation psig (0.017 bar) psig (0.035 bar) psig (0.017 bar) psig (0.017 bar) psig (0.035 bar) for 25 psig for 25 psig for 25 psig for 25 psig for 25 psig (1.7 bar) change (1.7 bar) change (1.7 bar) change (1.7 bar) change (1.7 bar) change Temperature Limits Manual drain: 0° to 160° F (-18° to 71° C) -20° to 180° F 0° to 160° F (-18° to 71° C) 0° to 160° F (-18° to 71° C) Auto drain: 32° to 160° F (0° to 71° C) (-29° to 82° C) 32° to 160° F (0° to 71° C) Low Temp. Option: -62° to 194° F (-52° to 90° C) -62° to 194° F (-52° to 90° C) Weight Manual drain: 1.2 lbs (0.54 kg) 1.71 lbs (0.78 kg) 1.2 lbs (0.54 kg) 1.15 lbs (0.52 kg) 1.38 lbs (0.68 kg) 1.0 lb (0.45 kg) 1.5 lb (0.68 kg) Auto drain: 1.42 lbs (0.64 kg) 1.65 lbs (0.75 kg) N/A N/A N/A 1.2 lb (0.54 kg) 1.5 lb (0.68 kg) Operating Media Air, Inert Gas & Sweet Natural Gas Air, Inert Gas & Sweet Air, Inert Gas & Sweet Natural Gas Air, Inert Gas & or Sour Natural Gas Sweet Natural Gas

Materials Body Diecast Aluminum Alloy, Irridite and Baked Epoxy Finish Filter Polyethylene Polyethylene None Polyethylene Diaphragm, Nitrile Elastomer and Nylon Fabric Viton Nitrile Elastomer and Nylon Fabric Nitrile Elastomer and Nylon Fabric Gasket, Pintle Low Temp. Option: Silicone and Nitrile Additional Materials Brass, Zinc Plated Steel, Acetal 316 Stainless Steel, Brass, Zinc Plated Steel, Acetal Aluminum, Heat Treated Plated Steel

Page 3: Type 330/335/340/345 Series - ControlAir · Type 345 Filter The Type 345 Filter unit is a 40-micron depth Glter that removes dirt, moisture and other particles from air and gas lines

air filtration and regulation

CB

.69

.63(16.0)

(17.5)

.63(16.0)

2.25(57.2)

2.25(57.2)

.34(8.64)MountingHoles2 Places

1/4 NPTGaugePort2 Places

IN OUT

.62(15.7)

A

.34 (8.64)

2 Places

Ø

Ø

E1/4 NPT

E1/2 NPT

FMax.

1/4 NPT

MountingBracket446-707-028

FMax.

1/2 NPT

MountingHoles

1.73(43.9)

3.10(78.7)

IN &OUTPorts1/4 OR1/2 NPT

D

1/8 NPT Drain

IN OUT

G

H1/4 NPTTappedExhaustPort (E) Option

1.44(36.6)

2.06(52.3)

(2) #10-24UNC x 3/8 DeepMounting HolesPanel Mount(P) Option

Knob (K)Option

J

CB

.69(17.5)

2.25(57.2)

2.25(57.2)

Mounting Holes

.34(8.64)MountingHoles2 Places

1/4 NPTGaugePort

IN OUT

.505(12.8)

A

1.73(43.9)

3.10(78.7)

KMax.

.34 (8.64)

2 Places

Ø

Ø

2 Places

Type 330/345 Dimensions (1/4” and 1/2” NPT) Type 340 Dimensions (1/4” and 1/2” NPT)

Sectional Drawings

Type 340 - 1/2" NPT

Type 330 - 1/4" NPTwith Auto Drain Option

Standard Auto Drain (A)

Panel MountTapped Exhaust

Type-335 NACE

M

MountingBracket446-707-028

1/4 NPTTappedExhaustPort (E) Option

(2) #10-24UNC x 3/8 DeepMounting HolesPanel Mount(P) Option

1.44(36.6)

2.06(52.3)

Max.1/4 NPT

F

OUTIN

H

G

IN(mm)

=Type 345

T T T T I ( O ( 0 M P M P F 4 N 4 C s 8 E 0 N S 1 N A L N E P f ( T M A L W M A O o

B D F D G A A T

Page 4: Type 330/335/340/345 Series - ControlAir · Type 345 Filter The Type 345 Filter unit is a 40-micron depth Glter that removes dirt, moisture and other particles from air and gas lines

8 Columbia Drive / Amherst, NH 03031 USA / www.controlair.com / [email protected] / 603-886-9400 / FAX 603-889-1844An ISO 9001:2015 Registered Company

Type 330/335/340/345 Series

P/N 441-625-057 4/19

GaugePorts (2)

NPTB 1/4"D 1/2"

Options (see descriptions)A AutodrainE Tapped ExhaustF 5 Micron FilterK KnobL Low TempN Non-RelievingP Panel MountR EAC TR-CUX ATEX

RangeA 0-30 psig (0-2 bar)B 0-60 psig (0-4 bar)C 0-120 psig (0-8 bar)

GaugePorts (2)

NPTB 1/4"

NACE FilterRegulator

335 – Options (see descriptions)F 5 Micron FilterN Non-Relieving

RangeA 0-30 psig (0-2 bar)B 0-60 psig (0-4 bar)C 0-120 psig (0-7 bar)

NPTB 1/4"D 1/2"

Regulator

340 – Options (see descriptions)E Tapped ExhaustK KnobL Low TempN Non-RelievingP Panel MountR EAC TR-CUX ATEX

RangeA 0-30 psig (0-2 bar)B 0-60 psig (0-4 bar)C 0-120 psig (0-8 bar)

NPTB 1/4"D 1/2"

Filter

345 – Options (see descriptions)A AutodrainF 5 Micron FilterL Low TempR EAC TR-CUX ATEX

Options Add proper letter at end of model number.A - Automatic Drain (Type 330 & 345): Float operated drain with 1/8”

NPT connection. Maximum 150 psig supply pressureE - Tapped Exhaust: Allows captured exhaust. 1/4" NPTF - 5 Micron Filter: Standard 40 micron filter is replaced with 5 micron

filter for more complete air filtrationK - Knob: Hand wheel to replace square head adjust screwL - Low Temperature: Range -62°F to 194°F (-52°C to 90°C)N - Nonrelieving: For constant flow or downstream pressure relief

applicationsR - EAC TR-CUX - ATEX 94/9/ECNote: Options A and L cannot be combined.

AccessoriesMounting Bracket: P/N 446-707-028Gauges: 1/4" NPT back-mount, 2" face, Dual Scale 0-15 psi (0-1 bar) P/N 446-725-003 0-30 psi (0-2 bar) P/N 446-725-004 0-60 psi (0-4 bar) P/N 446-725-001 0-160 psi (0-10 bar) P/N 446-725-002

Atmospheric Pressure

Regulated Pressure

Supply Pressure

B

BB

Principles of Operation - Type 330/335/340Turning the adjusting screw changes the force exerted by therange spring on the diaphragm assembly. In equilibrium of setpressure, the force exerted by the range spring is balanced bythe force from the output pressure acting underneath thediaphragm assembly. An unbalanced state between the outputpressure and the set pressure causes a corresponding reactionin the diaphragm and supply valve assemblies. If the outputpressure rises above the set pressure, an upward force isexerted on the diaphragm assembly causing the relief seat tolift and open. Excess pressure is vented to atmosphere untilequilibrium is reached. If the output pressure drops below theset pressure the unbalanced force of the range spring causes adownward force on the diaphragm assembly. The supply valvethen opens until the pressure builds up once more to theequilibrium condition. Under forward flow conditions, therange spring force is balanced by the diaphragm pressure force,with the supply valve open just enough to maintain therequired equilibrium pressure. When high flow occurs, aspecially designed aspirator helps maintain downstreampressure and compensates for droop.

Ordering Use this coding system to order

FilterRegulator

330 –

Warranty ControlAir, Inc. products are warranted to be free from defects in materialsand workmanship for a period of eighteen months from the date of sale, provided saidproducts are used according to ControlAir, Inc. recommended usages. ControlAir, Inc.’sliability is limited to the repair, purchase price refund, or replacement in kind, at Contro-lAir, Inc.’s sole option, of any products proved defective. ControlAir, Inc. reserves theright to discontinue manufacture of any products or change products materials, designsor specifications without notice. Note: ControlAir does not assume responsibility for theselection, use, or maintenance of any product. Responsibility for the proper selection,use, and maintenance of any ControlAir product remains solely with the purchaser andend user. Drawing downloads available at www.controlair.com