8
57 DM Series DM Series UM Series UM Series

UBE Air Drying Membranes

Embed Size (px)

DESCRIPTION

Air drying Membranes Technology by UBE.

Citation preview

  • 57DM SeriesDM Series UM SeriesUM Series

  • 58

    Compressed AirCompressed Air(Feed Gas)

    Product GasProduct Gas(Non-Permeate Gas)

    Dried AirDried AirWet AirWet Air

    Purge OutletPurge Outlet(Permeate Gas)

    (Purge Inlet)Purge Orifice

    HH22OO

    Polyimide Hollow Fiber

    Compressed AirCompressed Air(Feed Gas)

    Product GasProduct Gas(Non-Permeate Gas)

    Dried AirDried AirWet AirWet Air

    HH22OO

    HH22OO HH22OO

    Purge Air

    Module Structure Module Structure Air DryerAir Dryer

    Fixed Purge Orifice Type (DM Series)Fixed Purge Orifice Type (DM Series)

  • 59

    Compressed AirCompressed Air(Feed Gas)

    Product GasProduct Gas(Non-Permeate Gas)

    Dried AirDried AirWet AirWet Air

    Purge OutletPurge Outlet(Permeate Gas)

    Purge AirPurge Air

    HH22OO

    Polyimide Hollow Fiber

    Compressed AirCompressed Air(Feed Gas)

    Product GasProduct Gas(Non-Permeate Gas)

    Dried AirDried AirWet AirWet Air

    HH22OO

    HH22OO HH22OO

    Purge Air

    Module Structure Module Structure Air DryerAir Dryer

    Sweep Adjustment Valve Type (UM Series)Sweep Adjustment Valve Type (UM Series)

  • 60

    Type :Type : Asymmetrical Hollow MembraneAsymmetrical Hollow Membrane

    Material :Material : Aromatic PolyimideAromatic Polyimide

    General Operating Condition :General Operating Condition :TG > 300 TG > 300 CCAmbient Temperature :Ambient Temperature :

    5 ~ 80 0 C for Air DryerC for Air DryerOperation Temperature :Operation Temperature :

    5 ~ 60 60 C for Air DryerC for Air DryerOperation PressureOperation Pressure : :

    0.4 0.4 ~ 1.0 1.0 MPaGMPaG for Air Dryerfor Air DryerFeature :Feature : (1) High Permeation Flux(1) High Permeation Flux

    (2) Good Selectivity (2) Good Selectivity (3) Excellent Durability(3) Excellent Durability

    Membrane Material & Its FeatureMembrane Material & Its Feature

  • 61

    Air Dryer / Ideal System ConnectionAir Dryer / Ideal System Connection

    UBEUBEUBEUBEProduct Product Dried AirDried Air

    Purge OutletPurge Outlet

    CompressorCompressor

    AfterAfterCoolerCooler

    AirAirFilterFilter

    MistMistFilterFilter

    PressurePressureRegulatorRegulator

    StopStopValveValve

    PressurePressureGaugeGauge

    FlowFlowAdjustmentAdjustmentValveValve

    Inlet AirInlet Air

    Example of Direct Use Example of Direct Use Connecting to Connecting to CompressorCompressor

    Example of branched use from Example of branched use from CompressedCompressed--Air PipingAir Piping

    Compressed AirCompressed Air

    DM SeriesDM Series(Fixed Purge Orifice)(Fixed Purge Orifice)

    oror

  • 62

    Air Dryer / Ideal System ConnectionAir Dryer / Ideal System Connection

    Product Product Dried AirDried Air

    Purge OutletPurge Outlet

    CompressorCompressor

    AfterAfterCoolerCooler

    AirAirFilterFilter

    MistMistFilterFilter

    PressurePressureRegulatorRegulator

    StopStopValveValve

    PressurePressureGaugeGauge

    FlowFlowAdjustmentAdjustmentValveValve

    Inlet AirInlet Air

    Example of Direct Use Example of Direct Use Connecting to Connecting to CompressorCompressor

    Example of branched use from Example of branched use from CompressedCompressed--Air PipingAir Piping

    Compressed AirCompressed Air

    UM SeriesUM Series(Purge Adjustment Valve)(Purge Adjustment Valve)

    Purge Purge Adjustment Adjustment ValveValve

    oror

  • 63

    Water / Humidity:Water / Humidity:Liquid water should be avoidedLiquid water should be avoidedand less than 80 RH%and less than 80 RH%

    Small Particles:Small Particles: As few as possible, less than 0.01 As few as possible, less than 0.01 mmResidual Oil:Residual Oil: < 0.01mg/Nm3 (< 0.008 < 0.01mg/Nm3 (< 0.008 ppmppm w/ww/w))Hydrocarbons:Hydrocarbons: < 0.013mg/Nm3 (< 0.01 < 0.013mg/Nm3 (< 0.01 ppmppm w/ww/w) ) HH22S:S: < 3 < 3 volvol%%NHNH33 & Amines:& Amines: < 100 < 100 vppmvppmAcid:Acid: Should be avoidedShould be avoidedAromatics: Aromatics: As low as possible As low as possible Alcohol:Alcohol: GoodGood

    Durability against ContaminantsDurability against Contaminants

  • 64

    Simple Module structure and Flexible System DesignSimple Module structure and Flexible System Design

    Maintenance is very easy !!Maintenance is very easy !!

    LightweightLightweight and and CCompactompact

    No prescribed direction to be connectedNo prescribed direction to be connected-- You can set a membrane dryer every directions You can set a membrane dryer every directions

    (Vertical , Horizonta(Vertical , Horizontal l or Dor Diagonallyiagonally))

    No electric power requiredNo electric power required-- No control units and various parts driven by electric powerNo control units and various parts driven by electric power

    are requiredare required

    Advantage as compared with PSAAdvantage as compared with PSA