Important Security Instructions :
CAUTION! Carefully read this material before getting started. There are security measures to follow during the installation process.
The electric installation must be made according to NF C 15-100.
A circuit-breaker or splitting switch must be incorporated into cabling installation. This device must support the voltage value and nominal current indicated on the device. The products of GORY TIMING are compliant to: CE, EN60950, EN55022, and EN50024
UK048E User manual New range LEDIfi 3/16
Table of content
1 Assembly OVERVIEW .....................................................................................................................4
1.1 Wall mounting (LEDIfi Model) ....................................................................................................4
1.2 Flush mounting (LEDIfi ModEl) ..................................................................................................4
1.3 Ceiling mounting with bracket single and double face model(LEDIfi REVERSO Model) .........5
1.4 Side mounting with bracket - single and double face model (LEDIfi REVERSO Model) .............5
1.5 Mounting Bracket Assembly ......................................................................................................6
1.6 Clock and the mounting dimension............................................................................................7
2 General characteristics ....................................................................................................................8
3 ELECTRICAL Connections ..............................................................................................................9
3.1 LEDIfi model : current sector /time code/display ........................................................................9
3.1.1 Impulse receiver version, AFNOR NFS 87-500 code version, radio-synchronised version
on TDF or DCF ................................................................................................................................9
3.1.2 Version ASCII RS232 or RS485.........................................................................................9
3.2 LEDIfi REVERSO model: current sector/time code/display .......................................................9
3.2.1 Impulse Receiving Version, AFNOR NFS 87500 code, radio synchronized with TDF or
DCF .........................................................................................................................................10
3.2.2 Version ASCII RS232 or RS422........................................................................................10
3.3 Temperature probe (option).....................................................................................................11
4 Brightness setting ..........................................................................................................................11
5 Synchronisation .............................................................................................................................11
6 Configuration .................................................................................................................................12
UK048E User manual New range LEDIfi 4/16
1 ASSEMBLY OVERVIEW 1.1 WALL MOUNTING (LEDIfi MODEL)
1.2 FLUSH MOUNTING (LEDIfi MODEL)
Minimum opening85 mm
WALL
WIRE OUTPUT
63 mm
A-20 mm
B-20 mm
= =
A-10 mm
B-10 mm
=
=
Drilling for 3 mm screw
Wall opening depth 85 mm
Only for Ledi 5/60 ; 7/60 ; 7/60 alpha and alpha carr
UK048E User manual New range LEDIfi 5/16
1.3 CEILING MOUNTING WITH BRACKET SINGLE AND DOUBLE FACE MODEL(LEDIfi REVERSO MODEL)
1.4 SIDE MOUNTING WITH BRACKET - SINGLE AND DOUBLE FACE MODEL (LEDIfi REVERSO MODEL)
UK048E User manual New range LEDIfi 6/16
1.5 MOUNTING BRACKET ASSEMBLY
1. A plate is innitially fitted on the clock 2. Fix and secure the bracket with a threaded tube and two screws + washers. 3. Fit the other plate on the wall/ceilling, using porper method. 4. Finnish by assembling the clock + bracket to the wall/ceiling plate, again secure with screws and
washers.
clock
threaded pin
M3 screw
Clapper ring ceiling/wall
Bracket 50x30 mm
Clock clapper ring
puck
UK048E User manual New range LEDIfi 7/16
1.6 CLOCK AND THE MOUNTING DIMENSION
Model Digits Height
(hours/minutes) A(mm) B(mm)
A/2 (Ledifi Reverso)
(mm)
LEDIfi 5.S 50 300 120 150
LEDIfi 5.60 50 270 270 135
LEDIfi 7 70 350 165 175
LEDIfi 7.S 70 430 165 215
LEDIfi 7.60 70 390 390 195
LEDIfi 7.60.S 70 390 390 195
LEDIfi 10 100 500 210 250
LEDIfi 10.S 100 640 210 320
LEDICAfi 7.M 70 625 165 312.5
LEDICAfi 7.M.S 70 715 165 357.5
LEDICAfi ALPHA CARREE 7.M 70 390 390 195
LEDICAfi ALPHA 7.M 70 650 220 325
LEDICAfi ALPHA 7.M S 70 760 220 380
LEDICAfi ALPHA 7.60 70 390 540 195
LEDICAfi 10.M 100 770 210 385
LEDICAfi 10.M.S 100 930 210 465
UK048E User manual New range LEDIfi 8/16
2 GENERAL CHARACTERISTICS - 7 segment electroluminescent diode digital display Hour, Minute, second (option S ). - Tilt figures : 10 . - Power supply : 230 V AC ( 10%) / 50-60 Hz (115 V AC is an option) - Consumption: typical 10 W, may vary depending on model. - Time and and settings are saved by incorporated Lithium battery. - Tri colour LED red/green/yellow. White or blue on option. LEDIfi Range: Standard case Wall mounting or Flush mounting LEDIfi REVERSO Range: Single or double face Ceiling or side mounting w ith bracket support. AVAILABLE VERSIONS (according to model):
Stand alone version: TCXO quartz time base built-in 32Khz
Minute impulse input, parallel connection: Minute 24V reversed impulse. Impulsion duration: 0.1sec. Impulsion consumption : 6 mA / 24V
Half-minute impulse input, series connection : Series connection on an external 39 Ohms shunt. minute impulse reversed impulse every minute. Impulsion duration: 0.1sec. Impulsion consumption : 1.25 V Line intensity : 60 mA to 120 mA
AFNOR NFS 87500 input code Nominal input level : 2.2Vcc Input impendance : 3.5 Kohms Minimal input voltage : 70 mVcc
Ethernet version synchronised by NTP or PoE (Power over Ethernet): Uses a NTP server as time reference. Connect the mains supply for the NTP version. Make sure to use either a PoE switch or a Mid Span injector for the PoE version. The Ethernet interface user guide and the configuration tool are available on the CDROM supplied with the clock.
DHW 869.525MHz Radio input The clock is automatically synchronized according to the configuration of the transmitter.
Radiosynchronised on DCF Frequency: 77.5 KHz Place the antenna in a way that antennas LED is flashing every second and nothing at 59th seconds.
Radiosynchronised on TDF Frequency: 162 KHz Install the antenna on a horizontal basis. After a minute, the antennas LED should start flashing every second and nothing at 59th seconds.
Note: The maximum cables length using a shielded bi-wired cable is 100 meters. The maximum distance relative to the DCF transmitter (Frankfurt - Germany) or TDF (Allouis CHER) = 2,000 Kms. (Value may decrease depending on the surrounding terrain and weather conditions)
UK048E User manual New range LEDIfi 9/16
3 ELECTRICAL CONNECTIONS Wall Clock Fix the wall according to the previous paragraph. Flush Mount Clock Wall preparation: Prepare a opening which shall match the dimension for your clock(according to the previous paragraph). Fit in place the bracket with M3 screws (not supplied). Place your clock in the slot. This will be held in place automatically by magnetization. Wires output at the back of the case via the connector plug. 3.1 LEDIfi MODEL : CURRENT SECTOR /TIME CODE/DISPLAY Connect the mains power on the 2 wires + ground (Blue,Brown and Yellow/Green) After connection, set the clock on operation mode by switching ON (lower position).
3.1.1 Impulse receiver vers ion, AFNOR NFS 87-500 code version, radio-synchronised version on TDF or DCF Connect the impulse, AFNOR NFS 87500 code, TDF antenna or DCF antenna to the identified code input on terminal B1. If the 2 points CODE are not connected, the clock switches to stand alone version.(except for impulse receiver version) 3.1.2 Version ASCII RS232 or RS485 Connection on the terminal B1 The clock works as stand-alone but is set with respect to the ASCII code that it receives (configuration 2400 bauds, 8-bit format, even parity, 1stop bit). This ASCII code must be Time information in the form:
SXT day of week SP day of month/month/year SP SP hour: minute: second CR Generated either by RT4000 or by all other ASCII code generators.
Remark : In case of mains failure, the display turns off, but the time is save thanks to its internal battery. 3.2 LEDIfi REVERSO MODEL: CURRENT SECTOR/TIME CODE/DISPLAY
ASCII RS232C ASCII RS422/485
1 : GND 1 : E/S -
2 : TXD 2 : E/S+
3 : RXD 3 : GND
B1
CODEProbe T C
GND ASCII
RS232 ou RS485 E/S+
RXD
E/S- TXD
NC
OFF
ON
+
_
PROG
UK048E User manual New range LEDIfi 10/16
Connect the mains power on the 2 wires. The connections have to be made on this cable: the casing is sealed and cannot be opened. To access to the push buttons and the switch, unscrew and slip down the pit, which is located on the underside of the case. Switch on and reset the clock. 3.2.1 Impulse Receiv ing Version, AFNOR NFS 87500 code, rad io synchronized w ith TDF or DCF Connect the impulse, AFNOR NFS 87500 code, TDF antenna or DCF antenna on B1 connector (2 CODE points) 3.2.2 Version ASCII RS232 or RS422 Wiring code for ASCII 232 or 485 versions on RxD, TxD, GND
UK048E User manual New range LEDIfi 11/16
3.3 TEMPERATURE PROBE (OPTION) Connect the temperature probe on the 2 identified connector: Probe T C on terminal B1. The temperature probe is supplied with a 4meter cable. This cable may be eventually prolonged (25 meters length maxi) Accuracy +/- 0.4 C. If the measured temperature is indoor, the probe must be place between 1.50 and 2 m above ground and not close to any warm sources. If outdoor, the temperature probe must be placed under shelter, in a ventilated area, to avoid any direct sunlight or greenhouse effect. 4 BRIGHTNESS SETTING This setting is achieved manually by pressing the button + and outside any configuration mode. 5 SYNCHRONISATION To set the new minute, configure Hours/Minute, by pressing Prog and + or -, if any change are made on the minute unit, pressing PROG will start the newly settled minute. REMARKS - All phases of time setting are limited by duration of 80 seconds.
UK048E User manual New range LEDIfi 12/16
6 CONFIGURATION Setting the time is via 3 buttons +, - and PROG are accessible on the back panel. Keeping buttons +/- pressed will change value even faster. The setting time between the menus is 80 seconds
Hour/minute Configuration
+/- Hardware address value /
Software version
PROG
PROG
Colour choice d1=red d2=amber d3=green
Colour choice u1=red u2=amber u3=green
+/-
+/-
+/-
+/- Digits colour
Colour of circle Ledi 5.60 et Ledi 7.60
Configuration validation
Hours setting
Minutes setting
PROG
PROG
PROG
PROG
OFF
ON
+
_
PROG
UK048E User manual New range LEDIfi 13/16
Hour/minute Display Configuration
With alternate T C
5 ALT HOUR Tempo = 5 seconds
3 ALT HOUR Tempo = 3 seconds +/-
+/-
+/- Hardware address value /
Software version
Hour / Minute Tempo
Temperature tempo
PROG
PROG
PROG
Colour choice d1=red d2=amber d3=green
Colour choice u1=red u2=amber u3=green +/-
+/-
+/-
+/- Digits Colour
Colour of circle Ledi 5.60 et Ledi 7.60
Configuration validation
Hours setting
Minutes setting
PROG
PROG
PROG
PROG
PROG
UK048E User manual New range LEDIfi 14/16
Clock configuration w ith calendar
Date of month
MONTH / YEAR HOURS MINUTES Date of month
MONTH / YEAR
HOURS MINUTESDAY
Display on 2 digits
Dcalage de loffset par tranche de 30 minutes
3 ALT HOUR Tempo = 3 seconds
4 ALT HOUR Tempo = 4 seconds
+/-
Hardware address value / Software version
Month tempo
Year tempo
Digits colour
OFFSET shift
Configuration validation
Year setting
Month setting
Date of month setting
PROG
PROG
PROG
PROG
PROG
PROG
PROG
PROG
PROG
OFF (futur menu)
Language
PROG
PROG
+/-
+/-
+/-
+/-
+/-
+/-
+/-
+/-
+/-
Display configuration Hour/Minute (See preceding pages)
Colour choice d1=red d2=amber d3=green
UK048E User manual New range LEDIfi 15/16
Comments
Gorgy Timing RC74B38 All modifications of technical order, aesthetic, colour can be made without notice.