1
MATERIALS LEGEND B B LEVEL 02 -jk 114'- 0" W BOND I d sf 00 ^3" LEVEL 02 114'-0" vf LEVEL 02 114' - 0" AS-2 EXTERIOR LAB WING NORTH ENTRY ELEVATION WEST v 2 1/4" = i'-o" \ A5.01 EXTERIOR LAB WING NORTH ENTRY ELEVATION - NORTH 1/4" = r-o" A5.01 EXTERIOR LAB WING NORTH ENTRY ELEVATION - EAST i i i i i 1/4" = 1 *-0" NORTH PERSPECTIVE FOR INFORMATION ONLY - NOT FOR CONSTRUCTION TO DOME 205'• 1" TO MAS 178'-0" PENTHOUSE 175' -4" TO EAVE 172' -2" LEVEL 05 160'-0" LEVEL 04 144'. 8" LEVEL 03 129*-4" LEVEL 02 114' -0" LEVEL 01 100'-0" BASEMENT 84' - 8" CL in o in o CO CO EXTERIOR ELEVATION - NORTH rr_j 2' 4' 8" 16' 1/8" = r-o" \ A5.01 nui BRICK VENEER, 2-1/4" x 4" x 8" BRICKS, RUNNING BOND; FOR WALL ASSEMBLY REFER TO WA1 ON SHEET A2.01 HINGEBRICK, FOR SHAPE REFER TO DETAIL 18/A2.01 REINFORCED SOLDIER COURSE MASONRY LINTEL, 4" x 8" x 16" BRICKS, RE: STRUCTURAL BRICK VENEER SOLDIER COURSE PATTERN, 2 1/4" x 4" x 8" SPECIAL SHAPED SOLID BRICK AT OUTSIDE CORNER CONDITIONS SPLIT FACE LIMESTONE VENEER, RUNNING BOND; FOR WALL ASSEMBLY REFER TO WA2 ON SHEET A2.01 STANDING SEAM COPPER ROOF; FOR ROOF ASSEMBLY REFER TO RA1 ON SHEET A2.01 FLAT SEAM DIAMOND SHAPED COPPER SHINGLES; AT WALLS REFER TO WALL ASSEMBLY WA3 ON SHEET A2.01 LIMESTONE VENEER/CLADDING; FOR WALL ASSEMBLY REFER TO WA3 ON SHEET A2.01 INSULATED GLASS REINFORCED BRICK MASONRY, 4" X8" X16", RUNNING BOND (INTERIOR) -COLOR 1 COLOR 2 FLAT SEAM DIAMOND SHAPED COPPER ROOF SHINGLES AT DOME, REFER TO ROOF ASSEMBLY RA4 ON SHEET A2.01 EXPOSED CONCRETE EPDM WORK NOTES (__) 136 48"X48" ROOF HATCH WITH SAFETY GUARDRAILS 150 EXHAUST FAN STACKS, RE: MECHANICAL 151 COOLING TOWER, RE: MECHANICAL 513 LIMESTONE COPING, 8" HIGH 530 RECTANGULAR FLAT SEAM COPPER PANELS, SEAMS LOCATED AS SHOWN IN ELEVATIONS FOR WALL ASSEMBLY REFER TO WA4 ON SHEET A2.01 540 COPPER GUTTER WITH HEAT TRACE 541 COPPER DOWNSPOUT WITH HEAT TRACE 564 LIGHTNING PROTECTION, RE: ELECTRICAL 575 MECHANICAL EQUIPMENT, RE: MECHANICAL 580 LAMBS TONGUE, RE: PLUMBING 581 MASONRY LEDGE 582 BOLLARD LIGHT FIXTURE, RE: EL.ECTRICAL 587 RE: A5.05 FOR MASONRY LEDGE DIMENSIONS 589 CARVED LETTERING INTO LIMESTONE CLADDING 590 COPPER SCUPPER AND CONDUCTOR HEAD WITH HEAT TRACE 591 RECTANGULAR FLAT SEAM COPPER PANELS, SEAMS LOCATED AS SHOWN IN ELEVATIONS FOR WALL ASSEMBLY REFER TO WA5 ON SHEET A2.01 592 SECURITY CAMERA RE: TECH 593 ELECTRICAL OUTLET, RE: ELECTRICAL 596 WALL HYDRANT RE: PLUMBING 827 24" X 24" FIRE-RATED INSULATED ACCESS DOOR UNIVERSITY*/ NVER The Daniel Felix Ritchie School of Engineering and Computer Science + The Knoebel Center for The Study of Aging Mark Rodgers, AIA University Architect University of Denver Office of the University Architect 2400 South Race Street Denver, Colorado 80208 (303) 871-4746 Anderson Mason Da!a Architects Architect AndersonMasonDale Architects, P.C. 3198 Speer Boulevard Denver, Colorado 80211 (303) 294-9448 www.amdarchitects.com Structural Martin/Martin Consulting Engineers 12499 West Colfax Avenue Lakewood, Colorado 80215-3720 (303) 431-6100 www.martinmartin.com Mechanical / Electrical Shaffer Baucom Engineering & Consulting 7333 W Jefferson Ave, Suite 230 Lakewood, Colorado 80235 (303) 986-8200 www.sbengr.com Laboratory Research Facilities Design 3965 Fifth Avenue, Suite 400 San Diego, California 92103-3192 (619)297-0159 www.rfd.com Landscape Architect 5Design Inc. P.O. Box 724 Bailey, Colorado 80421-1838 (303) 838-5554 www.ldeasOutside.com Civil Anderson & Hastings Consultants, inc. 12596 W Bayaud Ave Lakewood, Colorado 80228 (303) 433-8486 www.ahceinc.com Code Advanced Consulting Engineers, Inc. 3900 S. Wadsworth, Unit 595 Lakewood, Colorado 80235 (720)981-4150 www.acecode.com Acoustics D. L. Adams & Associates, Inc. 1536 Ogden Street Denver, Colorado 80218 (303) 455-1900 www.dlaa.com Technology Rimrock A BCER Group 10807 New Allegiance Drive, Suite 400 Colorado Springs, Colorado 80921 (719)533-1112 www.rimrockgroup.com www.bcer.com AV K2 Audio, LLC 4900 Pearl East Circle Suite #201E Boulder, Colorado 80301 (303) 865-5500 www.k2audio.com Fire Protection Farnsworth Group, Inc. 8055 East Tufts Avenue, Suite 850 Denver, Colorado 80237 (303) 692-8838 www.f-w.com Issue ISSUE FOR BID Date 20 MARCH 2014 Project Number: Drawn By: Reviewed By: Approved By: 12-069 JF EH/JE AN EXTERIOR ELEVATION - NORTH A5.01 BRICK ARCH STACK •/:• "P'RE.Si -I G'.I O.US -/B-GNO..R it: ill: fuliki: IjjTj'yj j | j mfj uwtiseieai A5.07, BEYOND OPH A5.01 00 RFI 0729 ASI 019 ASI 036 2/A3.57 ASI 065

UNIVERSITY*/ NVER B - GH Phipps Construction Companiespix.ghphipps.com/projects/2013/13.0674/ProjDocs/04 - Record... · BRICK VENEER SOLDIER COURSE PATTERN, ... 587 RE: A5.05 FOR

  • Upload
    hatram

  • View
    213

  • Download
    1

Embed Size (px)

Citation preview

MATERIALS LEGEND

B B

LEVEL 02 -jk 114'- 0" W

BOND

Id

sf 00

^3"

LEVEL 02 114'-0" vf

LEVEL 02 114' - 0"

AS-2

EXTERIOR LAB WING NORTH ENTRY ELEVATION WEST

v 2 1/4" = i'-o" \ A5.01

EXTERIOR LAB WING NORTH ENTRY ELEVATION -NORTH

1/4" = r-o" A5.01

EXTERIOR LAB WING NORTH ENTRY ELEVATION -EAST i i i i i 1/4" = 1 *-0"

NORTH PERSPECTIVE FOR INFORMATION ONLY - NOT FOR CONSTRUCTION

TO DOME 205'• 1"

TO MAS 178'-0"

PENTHOUSE 175' -4"

TO EAVE 172' -2"

LEVEL 05 1 6 0 ' - 0 "

LEVEL 04 144'. 8"

LEVEL 03 129*-4"

LEVEL 02 114' -0"

LEVEL 01 100'-0"

BASEMENT 84' - 8"

CL in

o in

o CO

CO

EXTERIOR ELEVATION - NORTH rr_j

2' 4' 8" 16' 1/8" = r-o" \ A5.01

nui

BRICK VENEER, 2-1/4" x 4" x 8" BRICKS, RUNNING BOND; FOR WALL ASSEMBLY REFER TO WA1 ON SHEET A2.01

HINGEBRICK, FOR SHAPE REFER TO DETAIL 18/A2.01

REINFORCED SOLDIER COURSE MASONRY LINTEL, 4" x 8" x 16" BRICKS, RE: STRUCTURAL

BRICK VENEER SOLDIER COURSE PATTERN, 2 1/4" x 4" x 8" SPECIAL SHAPED SOLID BRICK AT OUTSIDE CORNER CONDITIONS

SPLIT FACE LIMESTONE VENEER, RUNNING BOND; FOR WALL ASSEMBLY REFER TO WA2 ON SHEET A2.01

STANDING SEAM COPPER ROOF; FOR ROOF ASSEMBLY REFER TO RA1 ON SHEET A2.01

FLAT SEAM DIAMOND SHAPED COPPER SHINGLES; AT WALLS REFER TO WALL ASSEMBLY WA3 ON SHEET A2.01

LIMESTONE VENEER/CLADDING; FOR WALL ASSEMBLY REFER TO WA3 ON SHEET A2.01

INSULATED GLASS

REINFORCED BRICK MASONRY, 4" X8" X16", RUNNING BOND (INTERIOR)

-COLOR 1 COLOR 2

FLAT SEAM DIAMOND SHAPED COPPER ROOF SHINGLES AT DOME, REFER TO ROOF ASSEMBLY RA4 ON SHEET A2.01

EXPOSED CONCRETE

EPDM

WORK NOTES (__)

136 48"X48" ROOF HATCH WITH SAFETY GUARDRAILS

150 EXHAUST FAN STACKS, RE: MECHANICAL 151 COOLING TOWER, RE: MECHANICAL 513 LIMESTONE COPING, 8" HIGH 530 RECTANGULAR FLAT SEAM COPPER

PANELS, SEAMS LOCATED AS SHOWN IN ELEVATIONS FOR WALL ASSEMBLY REFER TO WA4 ON SHEET A2.01

540 COPPER GUTTER WITH HEAT TRACE 541 COPPER DOWNSPOUT WITH HEAT TRACE 564 LIGHTNING PROTECTION, RE:

ELECTRICAL 575 MECHANICAL EQUIPMENT, RE:

MECHANICAL

580 LAMBS TONGUE, RE: PLUMBING 581 MASONRY LEDGE 582 BOLLARD LIGHT FIXTURE, RE:

EL.ECTRICAL 587 RE: A5.05 FOR MASONRY LEDGE

DIMENSIONS

589 CARVED LETTERING INTO LIMESTONE CLADDING

590 COPPER SCUPPER AND CONDUCTOR HEAD WITH HEAT TRACE

591 RECTANGULAR FLAT SEAM COPPER PANELS, SEAMS LOCATED AS SHOWN IN ELEVATIONS FOR WALL ASSEMBLY REFER TO WA5 ON SHEET A2.01

592 SECURITY CAMERA RE: TECH 593 ELECTRICAL OUTLET, RE: ELECTRICAL 596 WALL HYDRANT RE: PLUMBING 827 24" X 24" FIRE-RATED INSULATED ACCESS

DOOR

UNIVERSITY*/ NVER

The Daniel Felix Ritchie School of Engineering and Computer Science + The Knoebel Center for The Study of Aging

Mark Rodgers, AIA University Architect University of Denver Office of the University Architect 2400 South Race Street Denver, Colorado 80208 (303) 871-4746

Anderson Mason Da!a Architects

Architect AndersonMasonDale Architects, P.C. 3198 Speer Boulevard Denver, Colorado 80211 (303) 294-9448 www.amdarchitects.com

Structural Martin/Martin Consulting Engineers 12499 West Colfax Avenue Lakewood, Colorado 80215-3720 (303) 431-6100 www.martinmartin.com

Mechanical / Electrical Shaffer Baucom Engineering & Consulting 7333 W Jefferson Ave, Suite 230 Lakewood, Colorado 80235 (303) 986-8200 www.sbengr.com

Laboratory Research Facilities Design 3965 Fifth Avenue, Suite 400 San Diego, California 92103-3192 (619)297-0159 www.rfd.com

Landscape Architect 5Design Inc. P.O. Box 724 Bailey, Colorado 80421-1838 (303) 838-5554 www.ldeasOutside.com

Civil Anderson & Hastings Consultants, inc. 12596 W Bayaud Ave Lakewood, Colorado 80228 (303) 433-8486 www.ahceinc.com

Code Advanced Consulting Engineers, Inc. 3900 S. Wadsworth, Unit 595 Lakewood, Colorado 80235 (720)981-4150 www.acecode.com

Acoustics D. L. Adams & Associates, Inc. 1536 Ogden Street Denver, Colorado 80218 (303) 455-1900 www.dlaa.com

Technology Rimrock A BCER Group 10807 New Allegiance Drive, Suite 400 Colorado Springs, Colorado 80921 (719)533-1112 www.rimrockgroup.com www.bcer.com

AV K2 Audio, LLC 4900 Pearl East Circle Suite #201E Boulder, Colorado 80301 (303) 865-5500 www.k2audio.com

Fire Protection Farnsworth Group, Inc. 8055 East Tufts Avenue, Suite 850 Denver, Colorado 80237 (303) 692-8838 www.f-w.com

Issue

ISSUE FOR BID

Date

20 MARCH 2014

Project Number:

Drawn By:

Reviewed By:

Approved By:

12-069

JF

EH/JE

AN

EXTERIOR ELEVATION - NORTH

A5.01

BRICK ARCH STACK

•/:• "P'RE.Si -I G'.I O.US -/B-GNO..R

it: ill: fuliki:

IjjTj'yj j | j mfj

uwtiseieai

A5.07,

BEYOND OPH

A5.01 00

RFI 0729

ASI 019

ASI 036

2/A3.57

ASI 065