PLOVER USER GUIDE
SENSOR TAPPillar Sensor Taps & Bib Sensor Tap
FLAMINGOPELICANPENGUIN HERON PLOVER
3
SPECIFICATIONS
Pillar Tap Sensor Bib Tap Sensor
Control Box with Solenoid Valve
Installation & Troubleshooting Guide
Screw with PVC Sleeve (4 Pcs)
4 * AA' Size Duracell Alkaline batteries (In models AC&DC and Only DC)
Check Nut
Connector
Pillar Tap Body with 6 Pin Wire &PVC Pipe
Bib Tap Body with 6 Pin Wire
Control Box with Solenoid Valve
Installation & Troubleshooting Guide
Screw with PVC Sleeve (4 Pcs)
4 * AA' Size Duracell Alkaline batteries (In models AC&DC and Only DC)
SPECIFICATIONS PILLAR TAP SENSORS BIB TAP SENSORS
Power Consumption 2-5 Watts 2-5 Watts
Input Voltage 220 V AC/ 6V DC 220 V AC/ 6V DC
No. Of Batteries 4 x AA size Alkaline 4 x AA size Alkaline
Size of control boxunit
110x60x130 mm 110x60x130 mm
Life of Batteries Approx.25000 Cycles Approx.25000 Cycles
Models AC & DC/Only AC/Only DC
AC & DC/Only AC/Only DC
Sensor Type Infra-Red Sensor Infra-Red Sensor
COMPOSITION
ABOUT SENSOR TAPS
2
BENEFITS
Ark Sensor Taps are automatic faucets through which water flows only
when hands activate the fixture. These taps have built in infrared sensors
which sense the presense of an object i.e. user's hands in front of the tap
and sends signal to a solenoid valve to open. The flow automatically gets
terminated after a few seconds when the object is no longer present.
- Other than private residences, are also
suitable for public places i.e. public washrooms, particularly at
airports and hotels where they help reduce water consumption.
- As there are no points of contact transmission of
diseases is reduced.
- As excess water use is no longer an issue solely
for conservationists but also for the budget-conscious, sensors
can be seen as an investment as they pay for themselves with
reduced water consumption and maintenance costs.
Water Saving
Hygienic
Cost Saving
Our Sensor Taps models have the possibility to be powered by regular
AA batteries (Alkaline) or by mains 220 V AC via a 6V transformer or Both.
Automatic faucets were first developed in the 1950s but produced
commercially in the late 1980s. These have now become common in
developed countries. These save upto 70% water consumption.
HISTORY
4 55
INSTALLATION PROCEDUREPlease refer to the diagram:
Pillar Tap Sensors: (Fig. 1)
Install the Pillar Tap on the Wash Basin and tighten the Check
Nut.
Fix the connector on PVC pipe loose end.
Fix the other end of this Connector to the Control Box.
Bib Tap Sensors:
Fix Bib Tap Body on the wall socket of 1/2" Pipe Line .
Connect the other end of this 1/2" pipe line to the outlet of the
Control Box. Ensure that the control box is mounted vertically
as shown in fig. 2.
?
?
?
?
?
(Fig. 2)
CONTROL BOX INSTALLATION PROCEDURE:
For AC & DC and DC Models only:
Loosen the Control Box cover plate screws ( 6 Nos.)
(Only in AC & DC or DC models)
Remove the cover plate and insert AA size Alkaline Batteries
( 4 Nos.) inside theBattery Box.
Tighten the control box screws.
Fix the control box on the wall (Near or Below the tap).
Common for All Models :
Connect the water supply through valve V1 or Angle Valve and
then connect the pipe at inlet of Control Box.
Connect the 6 Pin Wire (from Pillar/Bib tap) to the Control Box
Connect the 3 pin plug to main supply only in case of AC/DC
and AC Models.
The Sensor Tap is now ready to work.
?
?
?
?
?
?
?
INSTALLATION DIAGRAM
INFR
ARED
RAYS
BIB
SEN
SO
R T
AP
WATER
PIP
ELI
NE
½ I
nch
INFR
ARED
SEN
SO
R
CO
NTRO
L BO
XLE
D
IND
ICATO
R
DIS
TAN
CE
AD
JUSTM
EN
T
SCREW
6 P
IN
CO
NN
ECTO
RW
ITH
WIR
EW
ATER
OU
TLE
T
WATER
INLE
T
V1
BIB
SEN
SO
R
PIL
LA
R S
EN
SO
R
WATER
OU
TLE
T
WATER
INLE
T
6 P
IN
CO
NN
ECTO
RW
ITH
WIR
E
LED
IN
DIC
ATO
R
DIS
TAN
CE
AD
JUSTM
EN
T
SCREW
INFR
ARED
RAYS
INFR
ARED
SEN
SO
R
FLEXIB
LE
PIP
E
V1
CO
NN
ECTO
R
PIL
LAR S
EN
SO
R T
AP
ELE
CTRIC
AL
SU
PPLY
ELE
CTRIC
AL
SU
PPLY
Fig.
1Fi
g.
2
6
IMPORTANT INFORMATION & GUIDELINES
1. Duracell Alkaline 'AA' size batteries should be used for DC
Models.
2. The Control Box should be fixed vertically as shown in
diagram.
3. Provide a Stop Valve on the inlet line of Control Box.
4. Unplug the Power Cable/ Remove Batteries if the sensor tap is
not in use for longer periods.
5. Ideal Sensing distance is 15 Cm which is pre fixed in the
Sensor (All Models).
6. The sensing distance can be also adjusted with the help of the
Distance Adjusting screw provided on the cover plate.( To be
touched only if required)
7. Make provision of a 3 Pin socket near the Control Box ( For
AC/DC and AC Models).
8. Ideal inlet Water pressure required is 1 Bar - 5 Bars (Max.)
9. The AC/DC model can operate either on Mains or Batteries.
In case of a power cut it automatically switches to battery.
77
TROUBLESHOOTING
Sr. No.
PROBLEM REASON ACTION
4.
1. Sensor connected but not working
Plug /Batteries not properly inserted.
Old Batteries
Check the Plug /Batteries and insert them properly.
Replace the Batteries.
Worn out Rubber Washers/Seal or loose joints
Replace Sealing Washers/ Tighten Joints
Batteries have not been inserted properly in the Battery Box in case of AC/DC and DC Models
Take out the batteries and fix them properly .
Switch of the Power and switch it on after waiting for 10 seconds
Leakages
Improper Flow
2.
Sensor Malfunctions:The Sensor fails to read the hand when placed in front
3.
Sensor cable not plugged properly (In all Models).
Unplug the sensor cable and fix it again
Washbasin is big or small in size due to which the pre fixed sensing distance of 15cm is not being maintained.
Reset sensing distance with the help of the adjustment screw on the cover plate as shown in figure by carefullyrotating the adjustment screw with help of a Screw Driver.
The Pillar/Bib Tap Aerator is clogged.
Pressure is less than 1Bar. Check the inlet pressure which should not be less than 1 Bar ideally.
Remove Aerator and clean it.
Problem in the Solenoid Valve which is damaged or dust particles deposited on the valve seat
5. Continuous Water Flow
Shut the power Off and On a couple of times in intervals of 10 Seconds
Check the Solenoid Valve repair/replace it.