4
CUTLINE A CUTLINE A KL01 RS01 TP Diag.602 - 750 mm KL03 B1VPF B2VPF T1VPF 001 002 003 004 005 006 007 008 009 010 L1VPF L2VPF L3VPF Diag.551.2 - 600 mm L4VPF Diag.551 - 600 mm D CUTLINE A CUTLINE A CUTLINE B CUTLINE B TP 010 011 012 013 014 015 016 017 018 019 020 021 022 L4VPF D L5VPF D T D L6VPF D T D T L7VPF L8VPF D D TC D HV WARNING HV WARNING HV WARNING 8200-1972-V1 20/10/14 Willow Brook Road, Corby 1:500 @ A Willow Brook Road Sheet 1 of 4 Key: Drawing no. Designer Date of issue Checked Issue Revision Scheme Name and Ward: Sheet Size Scale Authorised Streets on drawing: PRELIMINARY ORIG A1 NB AK CAG (07508 626810) Quantity - 1 Column - 10m Stainton (P/T) Lantern - Philips Mini-Iridium SGS451 GB With Telecell Optic - VX1 IT2 P1 Lamp - 60W CPO Quantity - 7 Column - 10m Stainton (P/T) Lantern - Philips Mini-Iridium SGS451 GB With Telecell Optic - VX2 IT2 P1 Lamp - 60W CPO Quantity - 2 Solar Powered Bollard Bollard - Signature Trueflex Face - Keep Left Quantity - 1 Illuminated Single-Headed Traffic Sign Column - 4.2m Stainton Heavy Duty Signlight - Reddilight Enterprise LED Lamp - LED 3.0W Quantity - 1 76mm Sign Post (Non-Illuminated) Column - 4m Straight Post Quantity - 21 Existing non DTC lighting column to be removed to tip off site Quantity - 1 Existing non DTC Illuminated Single-Head Traffic Sign to be removed to tip off site Quantity - 2 Existing non DTC Illuminated Bollard to be removed to tip off site New DNO Supply x 1 N Disconnection of DNO Supply x 1 D Transfer of DNO Supply x 7 T DRAWING / VIEW EXTENTS LINE HV WARNING WARNING - BURIED HV CABLES IN CLOSE PROXIMITY TO APPARATUS THIS SCHEME IS CMS CONTROLLED DUE TO THE PRESENCE OF HV PRE-SITE INVESTIGATIONS AND TRIAL HOLES ARE RECOMMENDED. ALL ILLUMINATED SIGN PLATES MUST BE REPLACED INCLUDING ANY THAT ARE BEING DE-ILLUMINATED UNLESS OTHERWISE AGREED. Transfer Coordinated of DNO Supply x 1 TC

V1-4 - Willow Brook Road

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: V1-4 - Willow Brook Road

CUTL

INE

A

CUTL

INE

A

KL01

RS01

TP

Diag.602 - 750 mm

KL03B1VPFB2VPF

T1VPF

001

002003

004

005

006007

008

009

010

L1VPF

L2VPF

L3VPF

Diag.551.2 - 600 mm

L4VPF

Diag.551 - 600 mm

D

CU

TLIN

E A

CU

TLIN

E A

CUTL

INE

B

CUTL

INE

B

TP

010

011012013

014

015

016

017

018

019

020

021

022

L4VPF

DL5VPF

DTD

L6VPF

D

T

D

T

L7VPF

L8VPF

D

D

TCD HV

WARNING

HVWARNING

HVWARNING

8200-1972-V1

20/10/14

Willow Brook Road,Corby

1:500 @ A1

Willow Brook RoadSheet 1 of 4

Key:

Drawing no.

Designer Date of issue

Checked

Issue Revision

Scheme Name and Ward:

Sheet Size ScaleAuthorised

Streets on drawing:

PRELIMINARY ORIG.

A1NBAK

CAG (07508 626810)

Quantity - 1Column - 10m Stainton (P/T)Lantern - Philips Mini-Iridium SGS451 GBWith TelecellOptic - VX1 IT2 P1 Lamp - 60W CPO

Quantity - 7Column - 10m Stainton (P/T)Lantern - Philips Mini-Iridium SGS451 GBWith TelecellOptic - VX2 IT2 P1 Lamp - 60W CPO

Quantity - 2Solar Powered BollardBollard - Signature TrueflexFace - Keep Left

Quantity - 1Illuminated Single-Headed Traffic SignColumn - 4.2m Stainton Heavy DutySignlight - Reddilight Enterprise LEDLamp - LED 3.0W

Quantity - 176mm Sign Post (Non-Illuminated)Column - 4m Straight Post

Quantity - 21Existing non DTC lighting column to beremoved to tip off site

Quantity - 1Existing non DTC Illuminated Single-HeadedTraffic Sign to be removed to tip off site

Quantity - 2Existing non DTC Illuminated Bollard to beremoved to tip off site

New DNO Supply x 1N

Disconnection of DNO Supply x 16D

Transfer of DNO Supply x 7T

DRAWING / VIEW EXTENTS LINE

HVWARNING

WARNING - BURIED HV CABLES INCLOSE PROXIMITY TO APPARATUS

THIS SCHEME IS CMS CONTROLLED

DUE TO THE PRESENCE OF HVPRE-SITE INVESTIGATIONS ANDTRIAL HOLES ARE RECOMMENDED.

ALL ILLUMINATED SIGN PLATES MUSTBE REPLACED INCLUDING ANY THATARE BEING DE-ILLUMINATED UNLESSOTHERWISE AGREED.

Transfer Coordinated of DNO Supply x 1TC

Page 2: V1-4 - Willow Brook Road

El Sub Sta

CUTLINE B

CUTLINE B

CU

TLIN

E C

CU

TLIN

E C TP

020

021

022

023

024

025

TP

026

17

280

027

TP

TP

028

029

030

031TP

032

RS02

TP

RS03

RS04033

034

035

TPTP

TP

Diag.611.1 - 600 diameter

Diag.611.1 - 600 diameter Diag.611.1 - 600 diameter

L8VP

F

TC

D

L9VPF

L10VPFL11VPF

T2VPF

T3VPF

T4VPF

HV

WAR

NIN

G

L12VPF

CU

TLIN

E C

CU

TLIN

E C

CUTL

INE

D

CUTL

INE

D

035

TP

TP

036037

038

039

47

100

040

041

RS05

RS06

RS07 042

043

044

Diag.611.1 - 600 diameterDiag.611.1 - 600 diameter

Diag.611.1 - 600 diameter

045

BB01

BB02046

047

L13VPF

L14VPF

T5VPF

T6VPF

T7VPF

L15VPF

L16VPF

11

300

Z1VPF

Z2VPF

20/10/14

1:500 @ A1

Key:

Drawing no.

Designer Date of issue

Checked

Issue Revision

Scheme Name and Ward:

Sheet Size ScaleAuthorised

Streets on drawing:

PRELIMINARY ORIG.

A1

8200-1972-V1

Willow Brook Road,Corby

Willow Brook RoadSheet 2 of 4

CAG (07508 626810)

AK NB

THIS SCHEME IS CMS CONTROLLED

DUE TO THE PRESENCE OF HVPRE-SITE INVESTIGATIONS ANDTRIAL HOLES ARE RECOMMENDED.

ALL ILLUMINATED SIGN PLATES MUSTBE REPLACED INCLUDING ANY THATARE BEING DE-ILLUMINATED UNLESSOTHERWISE AGREED.

Quantity - 8Column - 10m Stainton (P/T)Lantern - Philips Mini-Iridium SGS451 GBWith TelecellOptic - VX2 IT2 P1 Lamp - 60W CPO

Quantity - 6Illuminated Single-Headed Traffic SignColumn - 4.2m StaintonSignlight - Reddilight Enterprise LEDLamp - LED 3.0W

Quantity - 25Existing non DTC lighting column to beremoved to tip off site

Quantity - 6Existing non DTC Illuminated Single-HeadedTraffic Sign to be removed to tip off site

Quantity - 2Existing Pedestrian Crossing BelishaBeacon (Combined) unitColumn (To remain) - Clean, paint & wrapBeacon - Replace with SimmonsignsModubel LED unitLantern (Replace With - WRTL ARC-X FGLamp - 45W CPOWith Telecell

New DNO Supply x 2N

Disconnection of DNO Supply x 19D

Transfer of DNO Supply x 3T

DRAWING / VIEW EXTENTS LINE

HVWARNING

WARNING - BURIED HV CABLES INCLOSE PROXIMITY TO APPARATUS

Transfer Coordinated of DNO Supply x 3TC

Transfer Coordinated (1for1) x 6of DNO Supply

TC1

Page 3: V1-4 - Willow Brook Road

CUTL

INE

D

CUTL

INE

D

CU

TLIN

E E

CU

TLIN

E E

047

048

049

050

051

27

300

052

053

054

055

TP

L17VPF

L18VPFL19VPF

L20VPF

CUTL

INE

E

CUTL

INE

E

CU

TLIN

E F

CU

TLIN

E F

055

TP

056057

7

280

058

TP

059

060

061

TP062

TP

TP

063

20

250

064

TP

TP

L21VPF

L22VPF

L23VPF

L24VPF

L25VPF

L26VPF

8200-1972-V1

20/10/14

Willow Brook Road,Corby

1:500 @ A1

Willow Brook RoadSheet 3 of 4

Key:

Drawing no.

Designer Date of issue

Checked

Issue Revision

Scheme Name and Ward:

Sheet Size ScaleAuthorised

Streets on drawing:

PRELIMINARY ORIG.

A1

CAG (07508 626810)

AK NB

THIS SCHEME IS CMS CONTROLLED

DUE TO THE PRESENCE OF HVPRE-SITE INVESTIGATIONS ANDTRIAL HOLES ARE RECOMMENDED.

ALL ILLUMINATED SIGN PLATES MUSTBE REPLACED INCLUDING ANY THATARE BEING DE-ILLUMINATED UNLESSOTHERWISE AGREED.

Quantity - 7Column - 10m Stainton (P/T)Lantern - Philips Mini-Iridium SGS451 GBWith TelecellOptic - VX2 IT2 P1 Lamp - 60W CPO

Quantity - 3Column - 10m DTC (S/E)Bracket - 1.5m OutreachLantern - Philips Mini-Iridium SGS451 GBWith TelecellOptic - VX2 IT2 P1 Lamp - 45W CPO

Quantity - 276mm Sign Post (Non-Illuminated)Column - 4m Straight Post

Quantity - 15Existing non DTC lighting column to beremoved to tip off site

New DNO Supply x 2N

Disconnection of DNO Supply x 10D

Transfer of DNO Supply x 5T

DRAWING / VIEW EXTENTS LINE

HVWARNING

WARNING - BURIED HV CABLES INCLOSE PROXIMITY TO APPARATUS

Page 4: V1-4 - Willow Brook Road

CU

TLINE G

CU

TLINE G

TP

10B

076

077

10B

10B

10B

10B

10B

10B

10B

10B

078

079

080

081

082

083

084

TP

TP

TP

TP

L38VPF

L39VPF

L40VPF

L41VPF

L42VPF

L43VPF

L44VPF

L45VPFL46VPF

RS11T10VPF

Diag.611.1 - 600 diameter

Diag.602 - 750 mm

CU

TLIN

E F

CU

TLIN

E F

CU

TLINE G

CU

TLINE G

065

TP

TP

TP

066

067TP

TP

TP

TP

RS10 RS09

068

BB03

BB04

069

10B

10B

10B

10B

10B

070

07110B

072

10B

073

10B

074

10B

075

10B

076

L27VPFL28VPF

L29VPF

L31VPF

L32VPF

L30VPF

L33VPF

L34VPF

3

280

Z3VPFZ4VPF

L35VPF

L36VPF

L37VPF

L38VPF

Diag.616 - 600 mmDiag.616 - 600 mm

T8VPFT9VPF

8200-1972-V1

20/10/14

Willow Brook Road,Corby

1:500 @ A1

Willow Brook RoadSheet 4 of 4

Key:

Drawing no.

Designer Date of issue

Checked

Issue Revision

Scheme Name and Ward:

Sheet Size ScaleAuthorised

Streets on drawing:

PRELIMINARY ORIG.

A1

CAG (07508 626810)

NBAK

Quantity - 20Column - 10m DTC (S/E)Bracket - 1.5m OutreachLantern - Philips Mini-Iridium SGS451 GBWith TelecellOptic - VX2 IT2 P1 Lamp - 45W CPO

Quantity - 2Existing Pedestrian Crossing BelishaBeacon (Combined) unitColumn (To remain) - Clean, paint & wrapBeacon - Replace with SimmonsignsModubel LED unitLantern (Replace with) - WRTL ARC-X FGLamp - 45W CPOWith Telecell

Quantity - 1Illuminated Single-Headed Traffic SignColumn - 4.2m Stainton Heavy DutySignlight - Reddilight Enterprise LEDLamp - LED 3.0W

Quantity - 3Existing non DTC Illuminated Single-HeadedTraffic Sign to be removed to tip off site

DRAWING / VIEW EXTENTS LINE

HVWARNING

WARNING - BURIED HV CABLES INCLOSE PROXIMITY TO APPARATUS

THIS SCHEME IS CMS CONTROLLED

DUE TO THE PRESENCE OF HVPRE-SITE INVESTIGATIONS ANDTRIAL HOLES ARE RECOMMENDED.

ALL ILLUMINATED SIGN PLATES MUSTBE REPLACED INCLUDING ANY THATARE BEING DE-ILLUMINATED UNLESSOTHERWISE AGREED.

Quantity - 2Illuminated Single-Headed Traffic SignColumn - 4.2m StaintonSignlight - Reddilight Enterprise LEDLamp - LED 3.0W

Transfer Coordinated (1for1) x 3of DNO Supply

TC1