Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
OR
EG
ON
STA
TE U
NIV
ER
SITY
(O
SU)
VALLEY LIBRARY
ADA ASSESSMENT & SURVEY
ADA ON-CALL CONSULTING
Sacramento Office
770 L Street, Suite 950 Sacramento, CA 95814
Tel: 916.669.8750 Fax: 888.211.7441
Silicon Valley Office
2225 E. Bayshore Road, Suite 200
Palo Alto CA 94303 Tel: 866.694.7637
www.szs- consu lting.com
January 14, 2015
Angelo Gomez Executive Director
Office of Equity and Inclusion Oregon State University
330 Snell Hall Corvallis, OR 97331-2128
Re: ADA Accessibility Survey and Assessment – Valley Library
Dear Angelo,
We are pleased to submit this report for the Valley Library. This report is part of our project to
provide a Campus Accessibility Survey and Assessment for Oregon State University. It is our
hope that this report w ill assist OSU in improving access to people w ith disabilities to campus
facilities.
SZS has been pleased to be a part of this effort to evaluate campus buildings using federal and
state statutes and regulations, as w ell as universal design principles in order to create
performance standards that w ill guide design, construction and maintenance on campus.
We look forw ard to discussing our f indings w ith your team.
Regards,
Syroun Z. Sanossian, Principal
SZS Consulting Group LLC
ADA Assessment & Survey Valley Library
TABLE OF CONTENTS
1. EXECUTIVE SUM M ARY OF FINDINGS p. 1
a. Pedestrian Facilities and Exterior
Spaces Analyzed p. 2
b. Building Entrances p. 3
2. INTERIOR SPACES
First Floor p. 3
Second Floor p. 5
Third Floor p. 6
Fourth Floor p. 7
Fifth and Sixth Floors p. 7
3. BARRIER DATA RECORDS
Exterior Area Barriers p. 8
Interior Area Barriers p. 13
Cost Estimate p. 417
ADA Assessment & Survey Valley Library
1
1. EXECUTIVE SUMMARY OF FINDINGS
The field investigation for the interior spaces began on April 22, 2014. The exterior site
elements w ere assessed originally as part of the pedestrian facilities assessment in June-
September 2011 and are included as an essential part of this report. Images of each
physical element identif ied in this report w ere captured in HD digital photos w hile manual
measurements w ere taken to establish as-built conditions to facilitate the process of cost
estimating. Digital photographs are provided w ithin the report for each barrier to access , to
facilitate the review of the data collected. We have found that technical data can be diff icult
to interpret w ithout a visual component; the photos provide a clear connection betw een the technical data and each barrier to access.
The Valley Library building is comprised of both pre-ADA and post-ADA areas including an
alteration performed in 1996 and many barriers to access w ere identif ied in the building.
That is quite typical, as barriers to access exist in virtually every building, w hether new or existing.
No “perfect” building exists in the real w orld.
This ADA Assessment and Survey report is intended to not only identify barriers to access,
but to provide solutions. The basis for this ADA Assessment and Survey process is the
underlying desire on the part of OSU to improve access by relying on higher standards than
the minimum requirements in state and federal building codes. SZS intends to provide the
information in this report in a clear and easy to understand format. The information in this
report is compiled for use by designated OSU staff and other interested persons, so the content is designed to be understood by professionals and laymen alike.
The findings presented are both narrative and technical in nature; barriers to access
identif ied during the f ield investigation process are documented in tw o w ays;
1. Narrative Analysis: The analysis of f indings is contained in an executive summary in a
narrative form that not only describes each type of barrier identif ied but also provides a
discussion that analyses the functionality of physical elements. We also provide the
reasoning and research behind the identif ication of barriers that conflict w ith universal
design principles. This analysis may be accompanied by digital photographs or diagrams, w here applicable.
NOTE: Understanding building function and usage is essential w hen interpreting the f indings held in this report. The narrative is intended to facilitate this process.
2. Barrier Data Records: Individual barriers to access are entered into the SZS database
so that technical information on the barriers can be provided as barrier data records.
These barrier data records include digital photographs of each barrier identif ied, code
references that determine the barrier to access, as-built measurements, barrier severity
ratings, budgetary cost estimates, recommended solutions for barrier removal and a
priority for barrier removal. The information is formatted w ith tw o barriers on each report page.
ADA Assessment & Survey Valley Library
2
In order to consolidate the report data, some of the more typical barriers found in
multiple locations have been grouped w ithin the barrier data records w ith a description of the locations in w hich they w ere found.
A. Pedestrian Facilities and Exterior Spaces Analyzed
This report provides information on campus pedestrian facilities that serve the Valley
Library. Many physical elements are part of the comprehensive w hole that creates a
pedestrian facility. The fundamental elements evaluated as to w hether they provide
accessible pedestrian facilities include the follow ing:
Sidew alks
Walkw ays
Ramps
Curb Ramps
Blended Transitions
Signalized Intersections
Stairw ays (94% of people w ith disabilities are not mobility impaired)
Benches and other Seating Elements
Picnic Facilities
The descriptions provided for physical elements in this report are intended to clearly
describe the differences betw een each physical element, such as w hen a pedestrian route
is a sidew alk, rather than a w alkw ay. The descriptions are intended to explain how the
elements interact to form a cohesive pedestrian facility. Other more specif ic information
described w ithin this section intends to provide guidance on determinations made in this
report.
The key to providing accessible pedestrian facilities is in recognizing that different people
w ith disabilities have different needs. Setting policies that speak to the entire group is
essential, rather than focusing one particular subset of the overall group. Universal design
principles govern here – physical elements should be usable to everyone that visits campus
w ithout having to resort to any adaptation or specialized design.
In summary, an accessible route exists w ithin a building, property boundary or interior
space and is separate from the PROW. Pedestrian w alkw ays are similar to sidew alks as
paved surfaces improved for use by pedestrians but w alkw ays are not located along or
adjacent to the curb line, gutter or roadw ay and w alkw ays are generally not considered part
of the PROW. The pedestrian facility is the combination of the PROW and the accessible
route, w hich functions as a w hole to provide pedestrian access to facility entrances.
As a public building governed by the ADA Standards, the Valley Library should have at
least one accessible entrance. Accessible entrances w ere identif ied at the north side of the
building on f loor 2 and on the east side of the building on f loor 1. The Valley Library has an
accessible route provided w ithin the site from accessible parking spaces and accessible
passenger loading zones; public streets and sidew alks; and public transportation stops to
ADA Assessment & Survey Valley Library
3
the accessible building or facility entrance they serve1 as compared to the 2010 ADA
Standard for Accessible Design. Details on barriers identif ied in that route are provided
w ithin the ADA Assessment and Survey of the pedestrian facilities provided as a separate
report, as w ell as in the follow ing records. Please see the barrier data records for details.
B. Building Entrances
The building is located on the corner of Waldo Place and SW Jefferson Avenue in the
center of campus in front of a large Quad area. No parking is provided on-site. Grade level
accessible entrances are located on tw o sides and levels of the building.
INTERIOR SPACES
FIRST FLOOR
The Valley Library is a six-story building w ith multiple elevators. The building is provided w ith an
entry lobby on f loors 1 and 2 w ith circulation space, service desks, study rooms, classrooms,
meeting rooms and men and w omen’s restrooms, as w ell as lactation rooms on each floor.
Automatic door opening devices w ere provided at both accessible entrances, although ISA signs
identifying the doors as accessible w ere not provided. The
lobby, corridors and entry doors to public and staff areas
throughout the building w ere identif ied w ith tactile signage
but the Braille w as not located far enough from the raised
characters to allow reading, Braille dots w ere not domed
or rounded or located directly below tactile characters. In
general, the tactile signs in the building w ere quite
complex, multi-colored, multi-segmented signs that w ere
not accessible. Where provided, ISA symbols w ere less
than 1” high and part of a collage of information on the signs that may be diff icult for the visually
impaired to decipher (see photo above).
The first f loor is segmented into tw o sections. One section can be accessed by the accessible
entrance door located on the east side of the building. The second section can only be accessed
by use of the central or loading dock elevators. The
Rotunda Cafeteria w as located near the east accessible
entrance. The cafeteria lacked accessible food service
counters, tables and condiment counters. The men and
w omen’s restrooms located near the cafeteria w ere
identif ied w ith a number of barriers to access, the most
important being a lack of maneuvering clearance at
both entrance doors due to a high-low drinking fountain
w hich is located betw een the entrance doors to the tw o
facilities and the doors are heavy and lack accessible
signage.
1 2010 A DA Standards for A ccessible Design, Section 206.2.1 S ite A rriv al Points
ADA Assessment & Survey Valley Library
4
The facilities also have dispensers that protrude into the circulation path by more than 4” , the
lavatories are installed in counters that are higher than 34” and drainpipes have no insulation. This
is typical throughout the facility. The toilet stalls lacked accessible hardw are, grab bars and
dispensers w ere also not in accessible locations w ithin the stalls.
Overhead signs are posted in many locations w ithin corridors
that are accessible to people w ithout vision impairments but for
those w ith low vision or w ho are non-sighted that cannot see
above 80” high, the signs are not accessible. It is recommended
to provide tactile signage w ith the same information at doorw ay
entrances to these areas along the central corridors (see photo
at left).
Six elevators are provided in the building. Tw o elevators are
located w ithin the central corridor and across from the men and
w omen’s restrooms, a tw o-stop elevator is also provided near the main entrance on floor 2 that
connects the f irst f loor café area w ith the second floor and another elevator is located w ithin the
loading dock that is used by staff and student w orkers . The first f loor is segmented and the rest of
the f loor can only be accessed by using the central elevators w hich are quite far from the location
of the elevator serving the café and the central elevators are not visible from the entrance. Both
elevators lack door jamb signs that indicate discharge level. The elevator doors also lacked
adequate door delays, self -leveling capability at the elevator that serves the café, as it arrives w ith
a lip of one inch or more at each floor. Car call buttons are not located w ithin accessible reach
ranges and the buttons do not illuminate to indicate travel and audible controls or signals do not
function. The emergency controls function through the use of voice communication w hich may not be possible for people w ith speech or hearing impairments.
Open study areas w ere identif ied on the f irst f loor w ith study carrels that had accessible knee
clearance but electrical outlets necessary for use of personal digital devices (PC’s, tablets, phones,
etc.) w ere not w ithin accessible reach ranges. Book stacks w ere not identif ied w ith an accessible
route and in some areas, the w ay in w hich the stacks w ere arranged on the f loor encroached into
the clear w idth needed by people using mobility assist devices to travel through the stacks.
Stairw ay exit doors on this f loor also lacked accessible tactile signage. Presentation Room - Group
Study rooms and a lactation room located on this f loor also lacked accessible signage, entry doors
and adequate maneuvering space to allow people using w heelchairs to enter and close the door.
Central restrooms, including an accessible Family Restroom w ere located on f loor 1 w ere identif ied
w ith barriers similar to the restrooms described above near the cafeteria. High-low drinking
fountains are provided in the corridor leading to the elevator lobby across from the men and
w omen’s restrooms on each floor. The fountains are located in an alcove but the alcove is not deep
enough to conceal the entire fountain, resulting in a protruding hazard. On this f loor and other
f loors, the knee clearance measured w as not at least 27” high and most fountains did not operate
w ith 5 pounds of operating force or less. Group study rooms are provided on the f irst f loor and
most f loors in the building. Accessible group study rooms are also provided but these rooms lack
accessible signage, accessible tables and adequate maneuvering clearance to allow a person
using a w heelchair to enter the room and maneuver to use the table and w hiteboard. In these
instances, it may be necessary to remodel the rooms identif ied as accessible to provide w heelchair access.
ADA Assessment & Survey Valley Library
5
SECOND FLOOR
The main accessible entrance to the building is located on this f loor across from the main Quad. A
book depository w as located outside of the entrance door but the control to operate the drop w as
not located w ithin accessible reach ranges. Although accessible sliding doors w ere provided in the
entry vestibule, the entry doors w ere found to be lacking ISA signage, especially important in the
case w here all doors in the vestibule w ere not accessible. One door remains locked w ithin the
vestibule and is separate from the sliding doors. Vending machines in this area w ere also identif ied w ith controls that w ere not located w ithin accessible reach ranges.
A number of stairw ays w ere identif ied in this building. The handrails at all stairw ays w ere
accessible but tactile exit signs indicating w here doors lead to exits, including exit stairw ays are
also recommended in this building. Doors at stairw ay entrances w ithin open study areas w ere not
identif ied as accessible and existing tactile signs w ere not accessible. The stairw ays w ere
identif ied w ith signs provided for emergency personnel that provide information such as roof
access and stairw ay number w ith no tactile information. These particular signs have far more
information than is needed for the visually impaired in the case of an emergency. Also, no
contrasting color w as identif ied at the stairw ay treads w hich can be important to those w ith low
vision. As a performance standard, it is highly recommended to provide contrasting color at stairw ay treads to improve visibility for all users.
The digital services area to the right of the entrance w as identif ied w ith 4 different service desks all
located along a lengthy counter. At the end of the counter, a low er section of counter w as identif ied
but it w as not staffed. Policies and practices should be review ed to ensure that all 4 types of
services provided at the separate service desks can be provided at the single low er desks. Long
lines are common in that area and staff ing should be adequate to serve short people and people
using w heelchairs w ith the same services as those provided to the able-bodied visitors. Tw o PC
stations are also provided in the digital services area that both lack accessible knee clearance. At
least one of those stations should be usable for people w ith w heelchairs. The circulation desk w as identif ied w ith accessible service counter areas.
Restrooms w ere located centrally w ithin enclosed corridors that w ere not visible from either
accessible entrance. Also, many activities take place in the building w hich may be diff icult for
visitors w ith disabilities to locate. Lobby informational signage and ISA directional signs w ere not
identif ied in this building. Considering the complex nature of this facility, lobby informational signs
could be very helpful to many visitors. As a performance standard, it is recommended that lobby
identif ication signage be provided on each floor in each central corridor that indicates the f loor
plan, the location of the person view ing the sign and the location of accessible features such as
restrooms, elevator and drinking fountains in proximity to the location of the person reading the
sign.
Computer reference areas w ere located w ithin the central east-w est corridor on all f loors other
than 3. Those areas provided digital card catalogues, PC stations, copier machines, microfiche
and microf ilm readers. The counter w here the PC stations, etc. w ere located w as a f ixed counter
w ith a surface of 36” high and no knee clearance w as provided for people using w heelchairs .
Counter surfaces higher than 34” result in controls or mechanisms that are not accessible
(keyboards, computer mice, electrical outlets). Some free-standing optical recognition scanners
w ere also located on upper f loors and the controls and scanner beds w ere not w ithin accessible
reach ranges. Accessible built-in desks w ere provided on some of the upper f loors but the desks
did not all have PC computers at the desks. The Photocopy Center and Microcomputer Area on
f loor 2 w ere also identif ied w ith similar issues as described above. The Photocopy center lacked
ADA Assessment & Survey Valley Library
6
accessible w orkstations, copier card readers and copier card vending machines. The
Microcomputing center w as identif ied w ith 28 Mac stations in a zig-zag configuration that lacked
accessible knee clearance and 18 computer stations in a circular 6 seats configuration that w ere
not w heelchair accessible.
Collaborative Learning Center East and West w ere identif ied as open study areas w ith three
different types of desks w ith pedestal bases that w ere not w heelchair accessible. Study carrels
w ere identif ied on this f loor w ith accessible knee clearance but electrical outlets necessary for use
of personal digital devices (PC’s, tablets, phones, etc.) w ere not w ithin accessible reach ranges.
Many staff use only areas w ere identif ied in the building. These spaces include off ices, storage
rooms, janitorial rooms, mechanical or electrical rooms and associated spaces. Signage at the
door/doorw ay to these spaces w as included in this report as it is located along the public
circulation route of travel, but these interior spaces w ere not investigated as part of this
assessment process. In general, institutions and organizations make staff -use-only areas
accessible as needed through the reasonable accommodation process betw een the employer and
employee.
Barriers identif ied on this f loor w ere identif ied throughout the building in common use areas and
include entrance doors that lacked accessible signage and door closer operating force/sw eep
period w here door closers w ere installed. Franklin A McEdw ard Reading Area w as identif ied w ith
accessible study carrels but the lockers provided in the area w ere not accessible. The Thomas &
Beverly Hartung Gallery w as identif ied w ith accessible passage but the art objects in the space
w ere not accessible to those w ith vision impairments. It is recommended to provide information in
an alternate format describing those visual objects to provide access to people w ith vision
impairments.
The Autzen Classroom w as identif ied w ith non-accessible signs and entry doors. The classroom
w as provided w ith 24 Mac w orkstations and none w ere accessible.
THIRD FLOOR
Signage and public use areas on this f loor w ere similar to those described above. The Government
Documents Area and Library Catalogue Area lacked an accessible circulation route through the
area and the service counter at the catalogue desk also lacked an accessible section for short
people or people using w heelchairs. Entry door signage at the Williamette East & West Meeting
rooms w as not accessible and both rooms lacked podiums that had accessible w ork surface height
or accessible controls. Assistive listening systems w ere not provided in the conference or meeting
rooms. A kitchenette/break room used on this f loor w as identif ied w ith the same signage issues as
described above including a non-accessible f irst aid kit, and a kitchenette counter lacking
accessible w orkspace next to the stove and sink. The stove controls operation entailed reaching
over hotplates, w hich could be a safety risk for short people or people using w heelchairs.
Private study rooms are located along the east end of building and all of these rooms w ere
identif ied w ith rectangular pedestal-based tables other than the last room designated as an
accessible study room.
Men and w omen’s restrooms in the building w ere identif ied in one location on each floor. The
restrooms lacked accessible entry doors and automatic door opening devices are recommended.
Signage at the restrooms w as similar to the signs described above w ith non-accessible Braille,
ADA Assessment & Survey Valley Library
7
dispensers created protruding hazards w ithin the circulation path in each facility and lavatory
counters w ere higher than 34”. Urinals located in men’s rooms w ere not accessible. In addition,
knee clearance w as not accessible due to a cover placed over the drainpipes w hich encroached
into knee clearance necessary for people using w heelchairs .
Toilet stall doors did not self-close, hardw are w as not
provided, grab bars w ere not located in accessible locations
and dispensers located w ith the stalls w ere not accessible.
The Day Care Center on the 3rd f loor w as located in a small
space w ith an entry door, a large view panel and no door
closer device w as installed, but the door w as located w ithin
a few inches of a service counter w hich blocked
maneuvering clearance at the exit side of the door. Also, the
counters betw een the entry service area and the play area w ere only 27-1/2” apart (see photo at
left) w hich could prevent parents w ho use w heelchairs from entering the play area to tend to their
children. Service counter surfaces w ere also not at an accessible height.
Family/Assisted Restroom on floor 3 w as provided w ith an automatic door opening device but the
device lacked an ISA symbol that w as large enough to view from a distance. Otherw ise, barriers
identif ied in the facility w ere similar to those described above. A kitchenette w ithin a conference
room w as also identif ied w ith non-accessible counters, sink and dispensers.
FOURTH FLOOR
Barriers identif ied on this f loor in study areas, book stacks,
restrooms, elevators, classrooms and stairw ays w ere similar to
those noted above. The Administration & Consulting Services
department on this f loor w as identif ied w ith an accessible entry
door w ith an automatic door opening device that w as not
identif ied w ith an ISA symbol and BHMA “automatic door” signs
w ere not posted on both sides of the entry door. These signs
are important for both able-bodied people and for those w ith
disabilities that w ould access the door opening device. Some
tactile signs that are intended to be read by touch on this f loor
w ere located behind shelves that blocked approach to the
signs and doors (see photo at right).
FIFTH AND SIXTH FLOORS
Barriers identif ied on this f loor in study areas, book stacks, restrooms, elevators , classrooms and
stairw ays w ere similar to those noted above. The Special Collections Reading Room on this level
w as identif ied w ith a number of displays that lacked information accessible to the visually impaired.
Group study rooms w ere provided and some rooms w ere designated as accessible study rooms,
although the door signage w as not accessible and the rooms w ere provided w ith pedestal based
tables that lacked knee clearance and also blocked use of w hiteboards provided in each room. The
study rooms designated as accessible rooms w ere quite small and may need to be expanded to
provide w heelchair access.
The follow ing barrier data records provide more detailed information on the barriers described
above.
EXTERIOR AREA BARRIERS
OSU ‐ VALLEY LIBRARY
Field Date: 7/1/2011 Report Date 7/1/2011
Location: Exterior ‐ East Stairway
Barrier #: 442A
X Coordinate: 7478846.407
Barrier Area: Stairways
Barrier Type: Vertical Access ‐ Directional Sign
Barrier Description:
No form of vertical access provided at stairway to reach entry door or upper floors
Rec. Solution: Provide directional sign leading to accessible entry
Findings:
No information on alternate accessible entrance to building
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 403.1
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: 339933.686
Performance Standard: No
Reference Dwg: 1 of 8
Field Date: 7/1/2011 Report Date 7/31/2014
Location: Exterior ‐ East Stairway
Barrier #: 442B
X Coordinate: 7478846.407
Barrier Area: Stairways
Barrier Type: Handrail Extension ‐ Top
Barrier Description:
Extension does not extend horizontally above landing for min. 12" from first riser nosing
Rec. Solution: Provide accessible handrails at both sides of stairway
Findings:
Top handrail extension not parallel to ground surface
Quantity: LF
Notes:
Barrier Severity: 2 Recommended Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 505.10.2
As‐built : 2
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: 339933.686
Performance Standard: No
Reference Dwg: 1 of 8
ADA Assessment and Survey 2014 8
OSU ‐ VALLEY LIBRARY
Field Date: 7/1/2011 Report Date 7/31/2014
Location: Exterior ‐ East Stairway
Barrier #: 442C
X Coordinate: 7478846.407
Barrier Area: Stairways
Barrier Type: Handrail Extension ‐ Bottom
Barrier Description:
Extension not sloped for length of one tread beyond the last riser nosing
Rec. Solution: Provide accessible handrails at both sides of stairway
Findings:
Bottom handrail extension not min. 1 tread length
Quantity: LF
Notes:
Barrier Severity: 2 Recommended Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 505.10.3
As‐built : 4
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: 339933.686
Performance Standard: No
Reference Dwg: 1 of 8
Field Date: 7/1/2011 Report Date 7/1/2011
Location: Exterior ‐ Southeast Stairway
Barrier #: 445A
X Coordinate: 7478845.323
Barrier Area: Stairways
Barrier Type: Vertical Access ‐ Directional Sign
Barrier Description:
No form of vertical access provided at stairway to reach entry door or upper floors
Rec. Solution: Provide directional sign leading to accessible entry
Findings:
No information on alternate accessible entrance to building
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 403.1
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: 339894.023
Performance Standard: No
Reference Dwg: 1 of 8
ADA Assessment and Survey 2014 9
OSU ‐ VALLEY LIBRARY
Field Date: 7/1/2011 Report Date 7/1/2011
Location: Exterior ‐ Southeast Stairway
Barrier #: 445B
X Coordinate: 7478845.323
Barrier Area: Stairways
Barrier Type: Exit Stairway
Barrier Description:
Exit stairway does not provide min. 48" clear width between handrails
Rec. Solution: Reconfigure handrails to provide min. 48" clear width
Findings:
29" clear width between handrails
Quantity: LF
Notes:
Barrier Severity: 1 Necessary Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 2
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: 339894.023
Performance Standard: Yes
Reference Dwg: 1 of 8
Field Date: 7/1/2011 Report Date 7/1/2011
Location: Exterior ‐ Southeast Stairway
Barrier #: 445C
X Coordinate: 7478845.323
Barrier Area: Stairways
Barrier Type: Handrail ‐ Both Sides
Barrier Description:
No handrails provided at both sides of stairway
Rec. Solution: Provide handrails at both sides of stairway
Findings:
No handrail provided at both sides
Quantity: LF
Notes:
Barrier Severity: 2 Recommended Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 505.10.2
As‐built : 9
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: 339894.023
Performance Standard: No
Reference Dwg: 1 of 8
ADA Assessment and Survey 2014 10
OSU ‐ VALLEY LIBRARY
Field Date: 7/1/2011 Report Date 7/1/2011
Location: Exterior ‐ Southeast Stairway
Barrier #: 445F
X Coordinate: 7478845.323
Barrier Area: Stairways
Barrier Type: Contrasting Color ‐ ADA
Barrier Description:
No contrasting color on each tread of exterior stairway
Rec. Solution: Consider providing contrasting color on each tread
Findings:
No contrasting color provided
Quantity: LF or TR
Notes:
Barrier Severity: 2 Recommended Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS Advisory 504.4
As‐built : 24
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: 339894.023
Performance Standard: Yes
Reference Dwg: 1 of 8
Field Date: 7/12/2011 Report Date 7/12/2011
Location: Exterior ‐ West Control
Barrier #: 592A
X Coordinate: 7478636.219
Barrier Area: Controls and Mechanisms
Barrier Type: Control or Mechanism
Barrier Description:
Control or mechanism not at max. 48" high for side reach
Rec. Solution: Relocate control or mechanism to max. 48" high
Findings:
56" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 303.3
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: 339930.37
Performance Standard: No
Reference Dwg: 1 of 8
ADA Assessment and Survey 2014 11
OSU ‐ VALLEY LIBRARY
Field Date: 7/12/2011 Report Date 7/12/2011
Location: Exterior ‐ West Control
Barrier #: 592B
X Coordinate: 7478636.219
Barrier Area: Controls and Mechanisms
Barrier Type: Clear Floor Space
Barrier Description:
Clear floor space for wheelchair not provided at control or mechanism
Rec. Solution: Rework areas to provide wheelchair space at control or mechanism
Findings:
Bollard blocks control clear floor space
Quantity: SF
Notes:
Barrier Severity: 1 Necessary Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 303.3
As‐built : 10
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: 339930.37
Performance Standard: No
Reference Dwg: 1 of 8
Field Date: 7/12/2011 Report Date 7/12/2011
Location: Exterior ‐ Northeast Stairway
Barrier #: 584A
X Coordinate: 7478877.087
Barrier Area: Stairways
Barrier Type: Vertical Access ‐ Directional Sign
Barrier Description:
No form of vertical access provided at stairway to reach entry door or upper floors
Rec. Solution: Provide directional sign leading to accessible entry
Findings:
No information on alternate accessible entrance to building
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 403.1
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: 340089.661
Performance Standard: No
Reference Dwg: 1 of 8
ADA Assessment and Survey 2014 12
INTERIOR AREA BARRIERS
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Exit Vestibule V1091
Barrier #: 1A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Automatic Doors ‐ BHMA Sign
Barrier Description:
Swinging/sliding/folding door lacks sign visible from both sides reading, "AUTOMATIC DOOR"
Rec. Solution: Provide new signs showing on both approaches to door
Findings:
No BHMA signs at either set of automatic doors
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 2
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Exit Vestibule V1091
Barrier #: 1B
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Automatic Doors ‐ Sign
Barrier Description:
ISA symbol at automatic door opening device not min. 4" x 4" in size
Rec. Solution: Recommended: Provide ISA symbol min. 4" x 4" in size
Findings:
Existing symbol 1‐3/4" high. Nor visible from a distance
Quantity: JOB
Notes:
Barrier Severity: 1 Necessary Cost Est $500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 2
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 13
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Exit Vestibule V1091
Barrier #: 1C
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: ISA ‐ Accessible Entry Door
Barrier Description:
No sign identifying door as accessible where all doors are accessible
Rec. Solution: Provide ISA at accessible entrance door
Findings:
No ISA sign on inner set of double doors
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 216.6
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Lobby L1092
Barrier #: 2A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Tactile Exit Signs ‐ Door
Barrier Description:
Ground floor doors that exit to exterior lacks tactile exit sign
Rec. Solution: Provide sign stating “EXIT” at exit side of door
Findings:
Exit door with low level illuminated sign lacks tactile exit sign
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 216.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 14
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Lobby L1092
Barrier #: 2B
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Vending Machine ‐ High Reach Range
Barrier Description:
Vending machine point of control not at max. 48" high for side reach
Rec. Solution: Contact vendor to obtain replacement
Findings:
Vending machine card reader 61" high
Quantity: JOB
Notes:
Barrier Severity: 3 Hindrance Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Lobby L1092
Barrier #: 2C
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Lobby Info Sign
Barrier Description:
No lobby informational sign with location of accessible elements
Rec. Solution: Provide lobby informational sign
Findings:
Accessible sign not provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 15
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Lobby L1092
Barrier #: 2D
X Coordinate: N/A
Barrier Area: Corridors
Barrier Type: Protruding Object
Barrier Description:
Protruding object in in circulation path protrudes more than 4" between 27" and 80" high
Rec. Solution: Remove object or provide detectable warning (wing walls)
Findings:
Monitor protrudes 9‐5/8" at 34" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Lobby L1092
Barrier #: 2E
X Coordinate: N/A
Barrier Area: Lobby
Barrier Type: Control or Mechanism ‐ High Reach
Barrier Description:
Control or mechanism not at max. 48" high for side or parallel reach
Rec. Solution: Relocate control or mechanism to max. 48" high
Findings:
Book drop operating handle 56‐1/2" high
Quantity: EACH
Notes:
Barrier Severity: 4 Low Severity Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 16
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Lobby L1092
Barrier #: 2F
X Coordinate: N/A
Barrier Area: Drinking Fountains
Barrier Type: Knee Clearance
Barrier Description:
Fountain allows only side approach
Rec. Solution: Remount existing fountain with min. 27" knee clearance
Findings:
Low fountain has 26‐1/4" high knee clearance
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 306.3
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Lobby L1092
Barrier #: 2G
X Coordinate: N/A
Barrier Area: Drinking Fountains
Barrier Type: Operation ‐ Replacement
Barrier Description:
Operating mechanism involves more than 5 lbf to operate
Rec. Solution: Replace drinking fountain with accessible unit
Findings:
Needed more than 5 lbf where fountain is not adjustable
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 602.3
As‐built : 0
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 17
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Lobby L1092
Barrier #: 2H
X Coordinate: N/A
Barrier Area: Elevators
Barrier Type: Hall Call Buttons ‐ 42" High
Barrier Description:
The centerline of the hall call buttons not max. 42" above the floor
Rec. Solution: Replace hall call buttons
Findings:
42‐1/2" high on center
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $3,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 407.2.1
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Lobby L1092
Barrier #: 2I
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobes
Findings:
Strobes mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $1,100.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 2
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 18
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Rotunda Cafeteria 1099
Barrier #: 3A
X Coordinate: N/A
Barrier Area: Clear Floor Space
Barrier Type: Carpet/Rug
Barrier Description:
Carpet/rug not anchored to floor (possible trip hazard)
Rec. Solution: Secure exiting carpet/rugs or replace
Findings:
Door mat in front of stand not secure. Door mats at entry doorways also not secure
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $2,000.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 302.2
As‐built : 4
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Rotunda Cafeteria 1099
Barrier #: 3B
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Actuator/Control ‐ Hi/low Reach
Barrier Description:
Use of control involves low reach of less than 15" above floor or more than 48" high
Rec. Solution: Replace deli counter with counter at max, 34" high
Findings:
Deli display has items on top of counter above 48" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 308.2.2
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 19
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Rotunda Cafeteria 1099
Barrier #: 3C
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Actuator/Control ‐ Hi/low Reach
Barrier Description:
Use of control involves low reach of less than 15" above floor or more than 48" high
Rec. Solution: Relocate to area at min. 15" or max. 48" high or provide assistance
Findings:
Drink fridges have items higher than 48" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 308.2.2
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Rotunda Cafeteria 1099
Barrier #: 3D
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Clear Floor Space
Barrier Description:
Clear floor space for wheelchair not provided at control or mechanism
Rec. Solution: Move dispenser to accessible location
Findings:
Snack shelves and pillar block hand sanitizer clear floor space
Quantity: SF
Notes:
Barrier Severity: 3 Hindrance Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 0
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 20
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Rotunda Cafeteria 1099
Barrier #: 3E
X Coordinate: N/A
Barrier Area: Dining Facilities
Barrier Type: Condiment Stand ‐ Side Reach Obstructed (10"‐24")
Barrier Description:
Control or mechanism over an 10" to 24" obstruction max. 34" high located above 46"
Rec. Solution: Relocate control or mechanism to max. 46" high
Findings:
Utensils 46" high and 18" deep over an obstruction 34" high condiment stand
Quantity: EACH
Notes: Condiment stand type 1
Barrier Severity: 3 Hindrance Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Rotunda Cafeteria 1099
Barrier #: 3F
X Coordinate: N/A
Barrier Area: Dining Facilities
Barrier Type: Table Seating ‐ Ratio
Barrier Description:
Min. 5% of all tables of each type are not accessible
Rec. Solution: Provide min. 2 accessible tables of each type. Avoid pedestal base tables
Findings:
47 total tables identified. None are accessible
Quantity: EACH
Notes: 21 tall tables and 26 small pedestal tables
Barrier Severity: 2 Recommended Cost Est $1,800.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 902.2
As‐built : 4
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 21
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Rotunda Cafeteria 1099
Barrier #: 3G
X Coordinate: N/A
Barrier Area: Dining Facilities
Barrier Type: Condiment Stand ‐ Forward Reach Obstructed (10"‐25")
Barrier Description:
Control or mechanism over an 10" to 25" obstruction max. 34" high located above 44"
Rec. Solution: Relocate control or mechanism to max. 44" high
Findings:
Shelf with napkins, straws and etc. 47" high and 17" deep over an obstruction 33" high condiment stand
Quantity: EACH
Notes: Condiment stand type 2
Barrier Severity: 3 Hindrance Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 308.2
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Rotunda Cafeteria 1099
Barrier #: 3H
X Coordinate: N/A
Barrier Area: Dining Facilities
Barrier Type: Service Counter ‐ Surface Height
Barrier Description:
Counter surface not between 28" and 34" above floor or ground
Rec. Solution: Provide service counter with 3 ft segment with surface at max. 34" above floor or ground
Findings:
49‐1/2" high surface for small pick‐up counter
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $1,250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 902.2
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 22
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Rotunda Cafeteria 1099
Barrier #: 3I
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 77‐1/2" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Men's Restroom 1083
Barrier #: 4A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
62" high
Quantity: EACH
Notes: Also, braille not 3/8" and max. 1/2" directly below the tactile characters, braille on signs not located directly below tactile characters and braille dots on signs not domed or rounded
Barrier Severity: 1 Necessary Cost Est $500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 2
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 23
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Men's Restroom 1083
Barrier #: 4B
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Interior
Barrier Description:
Door opening force exceeds 5 lbf
Rec. Solution: Provide automatic door opening device
Findings:
15 lbf
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $5,000.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.9
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Men's Restroom 1083
Barrier #: 4C
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Sweep Period
Barrier Description:
Door closer lacks min. 5 second sweep period
Rec. Solution: Provide automatic door opening device
Findings:
2 second sweep
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.8.1
As‐built : 0
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 24
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Men's Restroom 1083
Barrier #: 4D
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Front App/push 12" SEC
Barrier Description:
Door/Gate at push side with min. 48" lacks min. 12" strike edge clearance with latch/closer
Rec. Solution: Provide automatic door opening device
Findings:
Drinking fountains block maneuvering clearance at entrance door
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS Figure 404.2.4.1
As‐built : 0
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Men's Restroom 1083
Barrier #: 4E
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Dispensers ‐ Protruding Object
Barrier Description:
Protruding dispenser creates protruding hazard in path of travel
Rec. Solution: Provide detectable warnings for the visually impaired
Findings:
Paper towel dispenser protrudes 10" at 44" high. Dryer protrudes 6" at 44" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $1,100.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307.2
As‐built : 2
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 25
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Men's Restroom 1083
Barrier #: 4F
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Lavatory ‐ Rim Height
Barrier Description:
Lavatory rim or counter edge is higher than 34" AFF
Rec. Solution: Replace lavatory
Findings:
34‐5/8" high AFF
Quantity: JOB
Notes:
Barrier Severity: 1 Necessary Cost Est $450.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 606.3
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Men's Restroom 1083
Barrier #: 4G
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Lavatory ‐ Drainpipes
Barrier Description:
Hot water and drainpipes accessible under lavatory not insulated or covered
Rec. Solution: Insulate drainpipes and hot water pipes
Findings:
No insulation provided
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $220.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 606.5
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 26
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Men's Restroom 1083
Barrier #: 4H
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Electrical Outlets ‐ Forward Reach Obstructed (10"‐25")
Barrier Description:
Outlet located over an 10" to 25" obstruction max. 34" high located above 44"
Rec. Solution: Relocate control or mechanism to max. 44" high
Findings:
44" high and 24" deep over an obstruction 34" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 308.2.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Men's Restroom 1083
Barrier #: 4I
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Stall Door Closer
Barrier Description:
Stall door not equipped with an automatic closing device
Rec. Solution: Replace compartment hinge with adjustible mechanism
Findings:
Stall door not self‐closing
Quantity: JOB
Notes:
Barrier Severity: 2 Recommended Cost Est $1,650.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.8.1.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 27
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Men's Restroom 1083
Barrier #: 4J
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Stall ‐ Door Hardware
Barrier Description:
Outside of compartment door lacks a loop or U‐pull below latch
Rec. Solution: Provide hardware
Findings:
No U‐pull provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $75.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.8.1.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Men's Restroom 1083
Barrier #: 4K
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Stall ‐ Door Hardware
Barrier Description:
Inside of compartment door lacks a loop or U‐pull below latch
Rec. Solution: Provide hardware
Findings:
No U‐pull provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $75.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.8.1.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 28
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Men's Restroom 1083
Barrier #: 4L
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet ‐ Rear Grab Bar
Barrier Description:
Rear grab bar not centered 12" from wall and 24" on the other side of WC
Rec. Solution: Replace grab bars with reinforcement
Findings:
14‐1/2" on center
Quantity: JOB
Notes:
Barrier Severity: 3 Hindrance Cost Est $450.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.5.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Men's Restroom 1083
Barrier #: 4M
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Centerline
Barrier Description:
Water closet centerline not between 16" and 18" O. C.
Rec. Solution: Relocate water closet
Findings:
18‐1/2" on center
Quantity: JOB
Notes:
Barrier Severity: 3 Hindrance Cost Est $850.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 29
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Men's Restroom 1083
Barrier #: 4N
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Seat Cover Dispenser
Barrier Description:
Seat cover dispenser not located on an accessible route. Blocked by water closet
Rec. Solution: Replace or remount dispenser on an accessible route with clear floor space
Findings:
Access to dispenser blocked by water closet
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $125.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Men's Restroom 1083
Barrier #: 4O
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Paper Dispenser
Barrier Description:
Toilet tissue dispenser not within 7" to 9" from front edge of toilet
Rec. Solution: Reposition or replace toilet paper dispenser
Findings:
12" from front edge of toilet
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $225.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.7
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 30
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Men's Restroom 1083
Barrier #: 4P
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Women's Restroom 1085
Barrier #: 5A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
62" high
Quantity: EACH
Notes: Also, braille not 3/8" and max. 1/2" directly below the tactile characters, braille on signs not located directly below tactile characters and braille dots on signs not domed or rounded
Barrier Severity: 1 Necessary Cost Est $500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 2
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 31
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Women's Restroom 1085
Barrier #: 5B
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Interior
Barrier Description:
Door opening force exceeds 5 lbf
Rec. Solution: Provide automatic door opening device
Findings:
18 lbf
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $5,000.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.9
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Women's Restroom 1085
Barrier #: 5C
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Sweep Period
Barrier Description:
Door closer lacks min. 5 second sweep period
Rec. Solution: Provide automatic door opening device
Findings:
2 second sweep
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.8.1
As‐built : 0
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 32
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Women's Restroom 1085
Barrier #: 5D
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Front App/push 12" SEC
Barrier Description:
Door/Gate at push side with min. 48" lacks min. 12" strike edge clearance with latch/closer
Rec. Solution: Provide automatic door opening device
Findings:
Drinking fountains block maneuvering clearance at entrance door
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS Figure 404.2.4.1
As‐built : 0
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Women's Restroom 1085
Barrier #: 5E
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Dispensers ‐ Protruding Object
Barrier Description:
Protruding dispenser creates protruding hazard in path of travel
Rec. Solution: Provide detectable warnings for the visually impaired
Findings:
Paper towel dispenser protrudes 10" at 42" high. Dryer and feminine product dispensers protrudes 6" at 43" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $1,650.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307.2
As‐built : 3
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 33
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Women's Restroom 1085
Barrier #: 5F
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Dispensers ‐ Sanitary Products
Barrier Description:
Feminine product dispenser does not operate at 5 lbf or less
Rec. Solution: Replace dispensers
Findings:
Exceed 5 lbf
Quantity: EACH
Notes: 2 of 2 feminine product dispensers
Barrier Severity: 1 Necessary Cost Est $650.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 603.3
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Women's Restroom 1085
Barrier #: 5G
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Lavatory ‐ Rim Height
Barrier Description:
Lavatory rim or counter edge is higher than 34" AFF
Rec. Solution: Replace lavatory
Findings:
34‐1/2" high AFF
Quantity: JOB
Notes:
Barrier Severity: 1 Necessary Cost Est $450.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 606.3
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 34
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Women's Restroom 1085
Barrier #: 5H
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Lavatory ‐ Knee Clearance
Barrier Description:
Lavatory bottom apron/edge not max 29" reducing to 27" at 8" back from edge
Rec. Solution: Remove cover over drainpipes at lavatory
Findings:
3" deep knee clearance
Quantity: JOB
Notes:
Barrier Severity: 1 Necessary Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 606.2 & 306
As‐built : 0
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Women's Restroom 1085
Barrier #: 5I
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Electrical Outlets ‐ Side Reach Obstructed (10"‐24")
Barrier Description:
Outlet located over an 10" to 24" obstruction max. 34" high located above 46"
Rec. Solution: Relocate control or mechanism to max. 46" high
Findings:
44" high and 26" deep over an obstruction 34" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 35
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Women's Restroom 1085
Barrier #: 5J
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Stall ‐ Door Hardware
Barrier Description:
Outside of compartment door lacks a loop or U‐pull below latch
Rec. Solution: Provide hardware
Findings:
No U‐pull provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $75.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.8.1.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Women's Restroom 1085
Barrier #: 5K
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Stall ‐ Door Hardware
Barrier Description:
Inside of compartment door lacks a loop or U‐pull below latch
Rec. Solution: Provide hardware
Findings:
No U‐pull provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $75.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.8.1.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 36
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Women's Restroom 1085
Barrier #: 5L
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Seat Cover Dispenser
Barrier Description:
Seat cover dispenser not located on an accessible route. Blocked by water closet
Rec. Solution: Replace or remount dispenser on an accessible route with clear floor space
Findings:
Access to dispenser blocked by water closet
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $125.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Women's Restroom 1085
Barrier #: 5M
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Paper Dispenser
Barrier Description:
Toilet tissue dispenser not within 7" to 9" from front edge of toilet
Rec. Solution: Reposition or replace toilet paper dispenser
Findings:
12" from front edge of toilet
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $225.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.7
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 37
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Women's Restroom 1085
Barrier #: 5N
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ North Study Area 1051
Barrier #: 6A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61‐1/2" high at rooms 1615 and 1071
Quantity: EACH
Notes: Also, braille not 3/8" and max. 1/2" directly below the tactile characters, braille on signs not located directly below tactile characters and braille dots on signs not domed or rounded
Barrier Severity: 1 Necessary Cost Est $500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 2
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 38
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ North Study Area 1051
Barrier #: 6B
X Coordinate: N/A
Barrier Area: Clear Floor Space
Barrier Type: Passageway ‐ Min. 36"
Barrier Description:
Circulation route not min. 36" wide between elements
Rec. Solution: Remove wall shelves in this location
Findings:
36" wide circulation route at passage point 38" long between moveable shelves and wall shelves
Quantity: LF
Notes:
Barrier Severity: 1 Necessary Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 403.5.1
As‐built : 0
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ North Study Area 1051
Barrier #: 6C
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobes
Findings:
Strobes mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $4,400.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 8
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 39
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ North Study Area 1051
Barrier #: 6D
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe ‐ Excessive Installation
Barrier Description:
Excessive installation of strobes (50' distance) may cause seizures
Rec. Solution: Recommended: remove excess strobe devices
Findings:
20' apart in some locations
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ North Study Area 1051
Barrier #: 6E
X Coordinate: N/A
Barrier Area: Counters and Tables
Barrier Type: Counter ‐ Surface Height
Barrier Description:
No section at least 3 feet long between 28" and 34" provided at existing counter
Rec. Solution: Provide min. 1 accessible dictonary stand on each floor. Recommended: indicate location in lob
Findings:
42" high dictonary stand with no knee clearance
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $875.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 902.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 40
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Central Hall H1000
Barrier #: 7A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Visual Information Provided (Exhibitions)
Barrier Description:
Visual sign providing information for program, service or activity not accessible
Rec. Solution: Provide information in alternate format to provide access to people with vision impairments
Findings:
Accessible sign not provided
Quantity: JOB
Notes:
Barrier Severity: 1 Necessary Cost Est $5,000.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
ADA Title II Technical Assistance Manual 3.2000 Denial of participation
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Central Hall H1000
Barrier #: 7B
X Coordinate: N/A
Barrier Area: Elevators
Barrier Type: Hall Call Buttons ‐ 42" High
Barrier Description:
The centerline of the hall call buttons not max. 42" above the floor
Rec. Solution: Replace hall call buttons
Findings:
42‐1/4" high on center
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $3,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 407.2.1
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 41
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Central Hall H1000
Barrier #: 7C
X Coordinate: N/A
Barrier Area: Corridors
Barrier Type: Strobe Height ‐ 80" on Wall
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 77‐1/2" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Copier/Library Catalogue Center 1062
Barrier #: 8A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Permanent Room/Space ‐ Tactile Characters
Barrier Description:
No tactile characters at sign identifying permanent rooms and spaces with visual signs
Rec. Solution: Provide accessible sign
Findings:
Overhead visual sign provided with no braille/tactile information at wall at entry point
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 216.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 42
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Copier/Library Catalogue Center 1062
Barrier #: 8B
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Electrical Outlets ‐ Side Reach Obstructed (10"‐24")
Barrier Description:
Outlet located over an 10" to 24" obstruction max. 34" high located above 46"
Rec. Solution: Relocate control or mechanism to max. 46" high
Findings:
Power strip below computer carrel surface hanging along back wall not accessible
Quantity: EACH
Notes: Computer carrel is accessible but lacks accessible outlets
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Copier/Library Catalogue Center 1062
Barrier #: 8C
X Coordinate: N/A
Barrier Area: Library Facilities
Barrier Type: Actuator/Control ‐ Side Reach Obstructed (10"‐24")
Barrier Description:
Control or mechanism over an 10" to 24" obstruction max. 34" high located above 46"
Rec. Solution: Provide min. 1 accessible scanner
Findings:
Scanner control displays 50" high and 16" deep
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 43
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Copier/Library Catalogue Center 1062
Barrier #: 8D
X Coordinate: N/A
Barrier Area: Counters and Tables
Barrier Type: Counter ‐ Surface Height
Barrier Description:
No section at least 3 feet long between 28" and 34" provided at existing counter
Rec. Solution: Provide min. 3 ft long section of counter at max. 34" high
Findings:
Entire counter 36" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $875.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 902.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Copier/Library Catalogue Center 1062
Barrier #: 8E
X Coordinate: N/A
Barrier Area: Counters and Tables
Barrier Type: Counter ‐ Knee Clearance
Barrier Description:
Knee clearance not min. 27" high, 19" deep or 30" wide
Rec. Solution: Provide min. 3 ft segment of accessible counter with min. 1 PC terminal for use
Findings:
No knee clearance at counter
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $875.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 44
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Copier/Library Catalogue Center 1062
Barrier #: 8F
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Actuator/Control ‐ Side Reach Obstructed (10"‐24")
Barrier Description:
Control or mechanism over an 10" to 24" obstruction max. 34" high located above 46"
Rec. Solution: Relocate min. one control or mechanism to max. 46" high
Findings:
Computer controls between 10" to 14" deep on counter 36" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ West Exit Stairway S1010
Barrier #: 9A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Tactile Exit Signs ‐ Stairway
Barrier Description:
Door leading directly into an exit stairway lacks tactile exit sign
Rec. Solution: Provide sign stating “EXIT STAIR DOWN (or UP)” at latch side of door
Findings:
Door to exit stair with low level illuminated sign lacks tactile exit sign
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 45
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ West Exit Stairway S1010
Barrier #: 9B
X Coordinate: N/A
Barrier Area: Stairways
Barrier Type: Sign ‐ Enclosed Exit Stairway (Ch 10)
Barrier Description:
Tactile stairway signage incorrectly indicates roof access, info for emergency personnel
Rec. Solution: Move existing sign and provide separate tactile stairway level sign at latch side of door
Findings:
Sign provided is misleading to the visually impaired
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
ICC A117.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ West Exit Stairway S1010
Barrier #: 9C
X Coordinate: N/A
Barrier Area: Clear Floor Space
Barrier Type: Protruding Object
Barrier Description:
Protruding object in circulation path protrudes more than 4" between 27" and 80" high
Rec. Solution: Provide detectable warning for the visually impaired
Findings:
Fire riser hose bib protrudes 16‐1/2" at 46" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 46
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ West Exit Stairway S1010
Barrier #: 9D
X Coordinate: N/A
Barrier Area: Stairways
Barrier Type: Contrasting Color ‐ ADA
Barrier Description:
No contrasting color on each tread of interior stairway
Rec. Solution: Recommended: Consider providing contrasting color on each tread
Findings:
Treads lack contrasting color defined as 70% contrast
Quantity: LF or TR
Notes:
Barrier Severity: 2 Recommended Cost Est $2,380.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS Advisory 504.4
As‐built : 68
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ West Exit Stairway S1010
Barrier #: 9E
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Horn/Strobe ‐ Common Use Area
Barrier Description:
No horn/strobes in common use areas
Rec. Solution: Provide strobe in common use area
Findings:
No device provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $5,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702.1
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 47
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Group Study Area
Barrier #: 10A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61‐3/4" high at offices 1081, 1212, 1220, 1720 and all group study room signs
Quantity: EACH
Notes: Also, braille not 3/8" and max. 1/2" directly below the tactile characters and braille dots on sign not domed or rounded
Barrier Severity: 1 Necessary Cost Est $2,250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 9
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Group Study Area
Barrier #: 10B
X Coordinate: N/A
Barrier Area: Clear Floor Space
Barrier Type: Passageway ‐ Min. 36"
Barrier Description:
Circulation route not min. 36" wide between elements
Rec. Solution: Rearrange stacks with min. 36" clear width
Findings:
Book stacks have 35‐1/2" clear width in multiple locations where stacks are double sided
Quantity: JOB
Notes:
Barrier Severity: 1 Necessary Cost Est $2,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 403.5.1
As‐built : 20
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 48
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Group Study Area
Barrier #: 10C
X Coordinate: N/A
Barrier Area: Library Facilities
Barrier Type: Clear Space ‐ 30" x 48"
Barrier Description:
Wheelchair space of min. 30" x 48" not provided
Rec. Solution: Move study carrel to provide access
Findings:
39" wide between stack ends and carrels at south side of space
Quantity: SF
Notes:
Barrier Severity: 2 Recommended Cost Est $75.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 304.3.2
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Group Study Area
Barrier #: 10D
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobes
Findings:
Strobes mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $1,650.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 3
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 49
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Presentation Room ‐ Group Study 1420
Barrier #: 11A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61" high at 2 entry doors
Quantity: EACH
Notes: Also, braille not 3/8" and max. 1/2" directly below the tactile characters and braille dots on sign not domed or rounded
Barrier Severity: 1 Necessary Cost Est $500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 2
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Presentation Room ‐ Group Study 1420
Barrier #: 11B
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Electrical Switches ‐ Height
Barrier Description:
Light switch control box top edge not at max. 48" high
Rec. Solution: Relocate switch box top edge to max. 48" high
Findings:
50" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 308.2
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 50
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Presentation Room ‐ Group Study 1420
Barrier #: 11C
X Coordinate: N/A
Barrier Area: Library Facilities
Barrier Type: Protruding Object
Barrier Description:
Protruding objects in in circulation path protrude more than 4" between 27" and 80" high
Rec. Solution: Remove objects or provide detectable warning (wing walls)
Findings:
Monitors on wall protrude 7" at 41" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $1,100.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307
As‐built : 2
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Presentation Room ‐ Group Study 1420
Barrier #: 11D
X Coordinate: N/A
Barrier Area: Classrooms
Barrier Type: Projector Screen Pull
Barrier Description:
Screen pull not at max. 48" high for side reach
Rec. Solution: Relocate to max. 48" high or provide extension
Findings:
Projector screen pull over 48" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $75.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 51
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Presentation Room ‐ Group Study 1420
Barrier #: 11E
X Coordinate: N/A
Barrier Area: Counters and Tables
Barrier Type: Podium ‐ Surface Height
Barrier Description:
Surface height exceeds 34" high
Rec. Solution: At least 1 podium or ensure that 5% of all podiums are accessible
Findings:
41" surface height
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $1,275.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 902.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Presentation Room ‐ Group Study 1420
Barrier #: 11F
X Coordinate: N/A
Barrier Area: Library Facilities
Barrier Type: Actuator/Control ‐ Hi/low Reach
Barrier Description:
Use of control involves low reach of less than 15" above floor or more than 48" high
Rec. Solution: Relocate to area at min. 15" or max. 48" high
Findings:
Phone control 60" high on center
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 308.2.2
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 52
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Presentation Room ‐ Group Study 1420
Barrier #: 11G
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Lactation/Group Study Room 1420
Barrier #: 12A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61" high
Quantity: EACH
Notes: Also, Braille not 3/8" and max. 1/2" directly below the tactile characters, Braille dots on sign not domed or rounded and Braille is not contracted Grade 2
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 53
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Lactation/Group Study Room 1420
Barrier #: 12B
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Electrical Switches ‐ Height
Barrier Description:
Light switch control box top edge not at max. 48" high
Rec. Solution: Relocate switch box top edge to max. 48" high
Findings:
50" high
Quantity: EACH
Notes: Lactation room sign lacks tactile information
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 308.2
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Lactation/Group Study Room 1420
Barrier #: 12C
X Coordinate: N/A
Barrier Area: Clear Floor Space
Barrier Type: Carpet/Rug
Barrier Description:
Carpet/rug not anchored to floor (possible trip hazard)
Rec. Solution: Secure exiting carpet/rug or replace
Findings:
Rug rolled on floor creates tripping hazard
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 302.2
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 54
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Lactation/Group Study Room 1420
Barrier #: 12D
X Coordinate: N/A
Barrier Area: Clear Floor Space
Barrier Type: Clear Floor Space ‐ 60" Turning Circle
Barrier Description:
Clear floor space of min. 60" in diameter not provided where 360 degree turn is made
Rec. Solution: Remove furniture or provide alternate space to provide min. 60" turning space
Findings:
Turning space and maneuvering clearance block by furniture
Quantity: SF
Notes:
Barrier Severity: 2 Recommended Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 304.3.1
As‐built : 0
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Lactation/Group Study Room 1420
Barrier #: 12E
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Horn/Strobe ‐ Common Use Area
Barrier Description:
No horn/strobes in common use areas
Rec. Solution: Provide strobe in common use area
Findings:
No device provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $5,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702.1
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 55
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Elevator/Restroom Corridor H1500
Barrier #: 13A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Permanent Room/Space ‐ Tactile Characters
Barrier Description:
No tactile characters at sign identifying permanent rooms and spaces with visual signs
Rec. Solution: Provide accessible sign
Findings:
Overhead visual sign info not provided in tactile signage at doorway within public route
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 216.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Elevator/Restroom Corridor H1500
Barrier #: 13B
X Coordinate: N/A
Barrier Area: Drinking Fountains
Barrier Type: Alcove ‐ New Construction
Barrier Description:
Fountain with a leading edge between 27" and 80" high protrudes more than 4" into the circulation path.
Rec. Solution: Demolish and construct new alcove as detectable warning
Findings:
Hi‐Low drinking fountain not completely inside alcove
Quantity: SF
Notes:
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307.2
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 56
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Elevator/Restroom Corridor H1500
Barrier #: 13C
X Coordinate: N/A
Barrier Area: Drinking Fountains
Barrier Type: Operation ‐ Replacement
Barrier Description:
Operating mechanism involves more than 5 lbf to operate
Rec. Solution: Replace drinking fountain with accessible unit
Findings:
Needed more than 5 lbf where fountain is not adjustable
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 602.3
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Elevator/Restroom Corridor H1500
Barrier #: 13D
X Coordinate: N/A
Barrier Area: Drinking Fountains
Barrier Type: Knee Clearance
Barrier Description:
Knee clearance under fountain not min. 27" high
Rec. Solution: Remount low drinking fountain with min. 27" high knee clearance
Findings:
26‐7/8" high knee clearance
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 306.3
As‐built : 0
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 57
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Elevator/Restroom Corridor H1500
Barrier #: 13E
X Coordinate: N/A
Barrier Area: Elevators
Barrier Type: Hall Call Buttons ‐ 42" High
Barrier Description:
The centerline of the hall call buttons not max. 42" above the floor
Rec. Solution: Replace hall call buttons
Findings:
42‐1/4" high on center
Quantity: EACH
Notes: Elevator 1 & 2 hall call buttons
Barrier Severity: 1 Necessary Cost Est $3,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 407.2.1
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Elevator/Restroom Corridor H1500
Barrier #: 13F
X Coordinate: N/A
Barrier Area: Corridors
Barrier Type: Strobe Height ‐ 80" on Wall
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 58
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Men's Restroom 1569
Barrier #: 14A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
62" high
Quantity: EACH
Notes: Also, Braille not 3/8" and max. 1/2" directly below the tactile characters, Braille dots on sign not domed or rounded and Braille is not contracted Grade 2
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Men's Restroom 1569
Barrier #: 14B
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Interior
Barrier Description:
Door opening force exceeds 5 lbf
Rec. Solution: Provide automatic door opening device
Findings:
15 lbf
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $5,000.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.9
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 59
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Men's Restroom 1569
Barrier #: 14C
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Sweep Period
Barrier Description:
Door closer lacks min. 5 second sweep period
Rec. Solution: Provide automatic door opening device
Findings:
2 second sweep
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.8.1
As‐built : 0
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Men's Restroom 1569
Barrier #: 14D
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Dispensers ‐ Protruding Object
Barrier Description:
Protruding dispenser creates protruding hazard in path of travel
Rec. Solution: Remove dispenser or provide detectable warning for the visually impaired
Findings:
Paper towel dispenser protrudes 10" at 44" high into lavatory
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307.2
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 60
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Men's Restroom 1569
Barrier #: 14E
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Lavatory ‐ Rim Height
Barrier Description:
Lavatory rim or counter edge is higher than 34" AFF
Rec. Solution: Replace lavatory
Findings:
34‐1/4" high AFF
Quantity: JOB
Notes:
Barrier Severity: 1 Necessary Cost Est $450.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 606.3
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Men's Restroom 1569
Barrier #: 14F
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Electrical Outlets ‐ Side Reach Obstructed (10"‐24")
Barrier Description:
Outlet located over an 10" to 24" obstruction max. 34" high located above 46"
Rec. Solution: Relocate control or mechanism to max. 46" high
Findings:
44" high and 20" deep over an obstruction 34‐1/4" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 61
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Men's Restroom 1569
Barrier #: 14G
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Urinal ‐ Rim
Barrier Description:
Min. 1 urinal has no elongated rim projecting 14" to 17" from wall
Rec. Solution: Replace urinal
Findings:
13" deep urinal
Quantity: JOB
Notes:
Barrier Severity: 2 Recommended Cost Est $800.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 605.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Men's Restroom 1569
Barrier #: 14H
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Stall Door Closer
Barrier Description:
Stall door not equipped with an automatic closing device
Rec. Solution: Replace compartment hinge with adjustible mechanism
Findings:
Stall door not self‐closing
Quantity: JOB
Notes:
Barrier Severity: 2 Recommended Cost Est $1,650.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.8.1.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 62
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Men's Restroom 1569
Barrier #: 14I
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Stall ‐ Door Hardware
Barrier Description:
Outside of compartment door lacks a loop or U‐pull below latch
Rec. Solution: Provide hardware
Findings:
No U‐pull provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $75.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.8.1.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Men's Restroom 1569
Barrier #: 14J
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Stall ‐ Door Hardware
Barrier Description:
Inside of compartment door lacks a loop or U‐pull below latch
Rec. Solution: Provide hardware
Findings:
No U‐pull provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $75.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.8.1.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 63
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Men's Restroom 1569
Barrier #: 14K
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Seat Cover Dispenser
Barrier Description:
Seat cover dispenser not located on an accessible route. Blocked by water closet
Rec. Solution: Replace or remount dispenser on an accessible route with clear floor space
Findings:
Access to dispenser blocked by water closet
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $125.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Men's Restroom 1569
Barrier #: 14L
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Paper Dispenser
Barrier Description:
Toilet tissue dispenser not within 7" to 9" from front edge of toilet
Rec. Solution: Reposition or replace toilet paper dispenser
Findings:
12" from front edge of toilet
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $225.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.7
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 64
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Men's Restroom 1569
Barrier #: 14M
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Accessible Family Restroom 1555
Barrier #: 15A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61" high
Quantity: EACH
Notes: Also, Braille not 3/8" and max. 1/2" directly below the tactile characters, Braille dots on sign not domed or rounded and Braille is not contracted Grade 2 and pictogram is not raised
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 65
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Accessible Family Restroom 1555
Barrier #: 15B
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Automatic Doors ‐ BHMA Sign
Barrier Description:
Swinging/sliding/folding door lacks sign visible from both sides reading, "AUTOMATIC DOOR"
Rec. Solution: Provide new sign showing on both approaches to door
Findings:
Accessible sign not provided
Quantity: EACH
Notes: No BHMA sign on either side of door. For signage; also, text descriptors not provided directly below pictogram. Sign on wall inside restroom inform users that they must move once over minute in order to
Barrier Severity: 1 Necessary Cost Est $500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 2
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Accessible Family Restroom 1555
Barrier #: 15C
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: ISA ‐ Accessible Entry Door
Barrier Description:
No sign identifying door as accessible where all doors are not accessible
Rec. Solution: Provide ISA at accessible entrance door
Findings:
ISA signs 1‐3/4" high on complex sign. Not visible from a distance
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 216.6
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 66
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Accessible Family Restroom 1555
Barrier #: 15D
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Dispensers ‐ Protruding Object
Barrier Description:
Protruding dispenser creates protruding hazard in path of travel
Rec. Solution: Remove dispensers or provide detectable warning for the visually impaired
Findings:
Paper towel dispenser protrudes 10" at 42" high. Feminine product dispenser protrudes 6" at 42" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $1,100.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307.2
As‐built : 2
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Accessible Family Restroom 1555
Barrier #: 15E
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Lavatory ‐ Rim Height
Barrier Description:
Lavatory rim or counter edge is higher than 34" AFF
Rec. Solution: Replace lavatory
Findings:
34‐1/4" high AFF
Quantity: JOB
Notes:
Barrier Severity: 1 Necessary Cost Est $450.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 606.3
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 67
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Accessible Family Restroom 1555
Barrier #: 15F
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Lavatory ‐ Knee Clearance
Barrier Description:
Lavatory bottom apron/edge not max 29" reducing to 27" at 8" back from edge
Rec. Solution: Remove cover at drainpipes
Findings:
6" deep knee clearance
Quantity: JOB
Notes:
Barrier Severity: 1 Necessary Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 606.2 & 306
As‐built : 0
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Accessible Family Restroom 1555
Barrier #: 15G
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Electrical Outlets ‐ Side Reach Obstructed (10"‐24")
Barrier Description:
Outlet located over an 10" to 24" obstruction max. 34" high located above 46"
Rec. Solution: Relocate control or mechanism to max. 46" high
Findings:
Electrical outlets behind dispensers and cannot be used
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 68
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Accessible Family Restroom 1555
Barrier #: 15H
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Centerline
Barrier Description:
Water closet centerline not between 16" and 18" O. C.
Rec. Solution: Relocate water closet
Findings:
18‐1/3" on center
Quantity: JOB
Notes:
Barrier Severity: 3 Hindrance Cost Est $850.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Accessible Family Restroom 1555
Barrier #: 15I
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Paper Dispenser
Barrier Description:
Toilet tissue dispenser not within 7" to 9" from front edge of toilet
Rec. Solution: Reposition or replace toilet paper dispenser
Findings:
14" from front edge of toilet
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $225.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.7
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 69
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Accessible Family Restroom 1555
Barrier #: 15J
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Seat Cover Dispenser
Barrier Description:
Seat cover dispenser not located on an accessible route. Blocked by water closet
Rec. Solution: Replace or remount dispenser on an accessible route with clear floor space
Findings:
Access to dispenser blocked by water closet
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $125.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Accessible Family Restroom 1555
Barrier #: 15K
X Coordinate: N/A
Barrier Area: Clear Floor Space
Barrier Type: Clear Floor Space ‐ 60" Turning Circle
Barrier Description:
Clear floor space of min. 60" in diameter not provided where 360 degree turn is made
Rec. Solution: Remodel area to provide min. 60" turning space
Findings:
57‐1/2" space between wall and lavatory. Counter protrudes into transfer space
Quantity: SF
Notes:
Barrier Severity: 2 Recommended Cost Est $3,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 304.3.1
As‐built : 20
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 70
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Accessible Family Restroom 1555
Barrier #: 15L
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Women's Restroom 1566
Barrier #: 16A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
62" high
Quantity: EACH
Notes: Also, Braille not 3/8" and max. 1/2" directly below the tactile characters, Braille dots on sign not domed or rounded and Braille is not contracted Grade 2
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 71
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Women's Restroom 1566
Barrier #: 16B
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Interior
Barrier Description:
Door opening force exceeds 5 lbf
Rec. Solution: Provide automatic door opening device
Findings:
18 lbf
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $5,000.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.9
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Women's Restroom 1566
Barrier #: 16C
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Sweep Period
Barrier Description:
Door closer lacks min. 5 second sweep period
Rec. Solution: Provide automatic door opening device
Findings:
2 second sweep
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.8.1
As‐built : 0
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 72
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Women's Restroom 1566
Barrier #: 16D
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Dispensers ‐ Protruding Object
Barrier Description:
Protruding dispenser creates protruding hazard in path of travel
Rec. Solution: Remove dispensers or provide detectable warning for the visually impaired
Findings:
Feminine product dispensers protrude 6" at 42" high into lavatory
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $1,100.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307.2
As‐built : 2
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Women's Restroom 1566
Barrier #: 16E
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Dispensers ‐ Sanitary Products
Barrier Description:
Feminine product dispenser does not operate at 5 lbf or less
Rec. Solution: Replace dispensers
Findings:
Exceed 5 lbf
Quantity: EACH
Notes: 2 of 2 feminine product dispensers
Barrier Severity: 1 Necessary Cost Est $650.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 603.3
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 73
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Women's Restroom 1566
Barrier #: 16F
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Electrical Outlets ‐ Forward Reach Obstructed (10"‐25")
Barrier Description:
Outlet located over an 10" to 25" obstruction max. 34" high located above 44"
Rec. Solution: Relocate control or mechanism to max. 44" high
Findings:
44" high and 23" deep with forward reach
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 308.2.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Women's Restroom 1566
Barrier #: 16G
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Stall ‐ Door Hardware
Barrier Description:
Outside of compartment door lacks a loop or U‐pull below latch
Rec. Solution: Provide hardware
Findings:
No U‐pull provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $75.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.8.1.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 74
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Women's Restroom 1566
Barrier #: 16H
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Stall ‐ Door Hardware
Barrier Description:
Inside of compartment door lacks a loop or U‐pull below latch
Rec. Solution: Provide hardware
Findings:
No U‐pull provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $75.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.8.1.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Women's Restroom 1566
Barrier #: 16I
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Seat Cover Dispenser
Barrier Description:
Seat cover dispenser not located on an accessible route. Blocked by water closet
Rec. Solution: Replace or remount dispenser on an accessible route with clear floor space
Findings:
Access to dispenser blocked by water closet
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $125.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 75
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Women's Restroom 1566
Barrier #: 16J
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Paper Dispenser
Barrier Description:
Toilet tissue dispenser not within 7" to 9" from front edge of toilet
Rec. Solution: Reposition or replace toilet paper dispenser
Findings:
12" from front edge of toilet
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $225.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.7
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Women's Restroom 1566
Barrier #: 16K
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 76
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Lobby Room L1711
Barrier #: 17A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61" high at room 1711
Quantity: EACH
Notes: Also, Braille not 3/8" and max. 1/2" directly below the tactile characters, Braille dots on sign not domed or rounded and Braille is not contracted Grade 2
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Lobby Room L1711
Barrier #: 17B
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Interior
Barrier Description:
Door opening force exceeds 5 lbf
Rec. Solution: Provide automatic door opening device
Findings:
17 lbf
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $5,000.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.9
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 77
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Lobby Room L1711
Barrier #: 17C
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Sweep Period
Barrier Description:
Door closer lacks min. 5 second sweep period
Rec. Solution: Provide automatic door opening device
Findings:
3 second sweep
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.8.1
As‐built : 0
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Lobby Room L1711
Barrier #: 17D
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61" high at rooms 1715 and 1713
Quantity: EACH
Notes: Also, braille on sign not located directly below tactile characters and contracted (Grade 2) braille not used on sign
Barrier Severity: 1 Necessary Cost Est $500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 2
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 78
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Elevator 1
Barrier #: 18
X Coordinate: N/A
Barrier Area: Elevators
Barrier Type: Hall Call Buttons ‐ 42" High
Barrier Description:
The centerline of the hall call buttons not max. 42" above the floor
Rec. Solution: Replace hall call buttons
Findings:
42‐3/4" high on center
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $3,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 407.2.1
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ West Enclosed Exit Stairway S1710
Barrier #: 19A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
60‐3/4" high
Quantity: EACH
Notes: Also, braille dots on sign not domed or rounded
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 79
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ West Enclosed Exit Stairway S1710
Barrier #: 19B
X Coordinate: N/A
Barrier Area: Stairways
Barrier Type: Sign ‐ Enclosed Exit Stairway Door
Barrier Description:
Door leading directly into an exit stairway lacks tactile exit sign
Rec. Solution: Provide sign stating “EXIT STAIR DOWN (or UP)” at latch side of door
Findings:
Door to exit stair with low level illuminated sign lacks tactile exit sign
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ West Enclosed Exit Stairway S1710
Barrier #: 19C
X Coordinate: N/A
Barrier Area: Stairways
Barrier Type: Sign ‐ Enclosed Exit Stairway Level
Barrier Description:
Tactile stairway signage not provided to indicate floor level
Rec. Solution: Provide sign
Findings:
No sign provided
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
ICC A117.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 80
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ West Enclosed Exit Stairway S1710
Barrier #: 19D
X Coordinate: N/A
Barrier Area: Stairways
Barrier Type: Contrasting Color ‐ ADA
Barrier Description:
No contrasting color on each tread of interior stairway
Rec. Solution: Recommended: Consider providing contrasting color on each tread
Findings:
Treads lack contrasting color defined as 70% contrast
Quantity: LF or TR
Notes:
Barrier Severity: 2 Recommended Cost Est $2,380.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS Advisory 504.4
As‐built : 68
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ West Enclosed Exit Stairway S1710
Barrier #: 19E
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Horn/Strobe ‐ Common Use Area
Barrier Description:
No horn/strobes in common use areas
Rec. Solution: Provide strobe in common use area
Findings:
No device provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $5,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702.1
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 81
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ East Enclosed Exit Stairway S1790
Barrier #: 20A
X Coordinate: N/A
Barrier Area: Stairways
Barrier Type: Sign ‐ Enclosed Exit Stairway Door
Barrier Description:
Door leading directly into an exit stairway lacks tactile exit sign
Rec. Solution: Provide sign stating “EXIT STAIR DOWN (or UP)” at latch side of door
Findings:
Door to exit stair with low level illuminated sign lacks tactile exit sign
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ East Enclosed Exit Stairway S1790
Barrier #: 20B
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Interior Adjustment
Barrier Description:
Door opening force exceeds 5 lbf
Rec. Solution: Replace or adjust existing closers. Door does not lead to an accessible route
Findings:
17 lbf at entry doors to stairway and 19 lbf at door to exterior
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $1,350.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.9
As‐built : 3
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 82
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ East Enclosed Exit Stairway S1790
Barrier #: 20C
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Interior Sweep Period
Barrier Description:
Door closer lacks min. 5 second sweep period or does not stop 5" from door frame
Rec. Solution: Replace or adjust existing closers. Door does not lead to an accessible route
Findings:
3 second sweep at all 3 doors within stairway
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.8.1
As‐built : 3
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ East Enclosed Exit Stairway S1790
Barrier #: 20D
X Coordinate: N/A
Barrier Area: Stairways
Barrier Type: Contrasting Color ‐ ADA
Barrier Description:
No contrasting color on each tread of interior stairway
Rec. Solution: Recommended: Consider providing contrasting color on each tread
Findings:
Treads lack contrasting color defined as 70% contrast
Quantity: LF or TR
Notes:
Barrier Severity: 2 Recommended Cost Est $2,380.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS Advisory 504.4
As‐built : 68
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 83
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Accessible Group Study Room 1862
Barrier #: 21A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61‐3/4" high
Quantity: EACH
Notes: Also, braille not 3/8" and max. 1/2" directly below the tactile characters and braille dots on sign not domed or rounded.
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Accessible Group Study Room 1862
Barrier #: 21B
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Electrical Switches ‐ Height
Barrier Description:
Light switch control box top edge not at max. 48" high
Rec. Solution: Relocate switch box top edge to max. 48" high
Findings:
50" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 308.2
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 84
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Accessible Group Study Room 1862
Barrier #: 21C
X Coordinate: N/A
Barrier Area: Library Facilities
Barrier Type: Table ‐ Clear Floor Space
Barrier Description:
Clear floor space 30" x 48" not provided at table
Rec. Solution: Provide table in accessible location
Findings:
No wheelchair maneuvering clearance in room between table and whiteboards to allow for use
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $450.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Accessible Group Study Room 1862
Barrier #: 21D
X Coordinate: N/A
Barrier Area: Library Facilities
Barrier Type: Table ‐ Pedestal Base
Barrier Description:
Knee clearance not min. 27" high, 19" deep or 30" wide
Rec. Solution: Provide min. 1 accessible table. Avoid pedestal base tables
Findings:
Pedestal base blocks knee clearance
Quantity: EACH
Notes: Pedestal based table
Barrier Severity: 2 Recommended Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 306.2.2 and 306.2.3
As‐built : 0
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 85
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ Accessible Group Study Room 1862
Barrier #: 21E
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ East Exit Stairway S1090
Barrier #: 22A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Permanent Room/Space ‐ Tactile Characters
Barrier Description:
No tactile characters at sign identifying permanent rooms and spaces with visual signs
Rec. Solution: Provide accessible sign
Findings:
No tactile signage provided at door within public route
Quantity: EACH
Notes: Fire sprinkler room door sign
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 216.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 86
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ East Exit Stairway S1090
Barrier #: 22B
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Tactile Exit Signs ‐ Passage
Barrier Description:
Exit thru an exit enclosure/exit passageway lacks tactile exit sign
Rec. Solution: Provide sign stating “EXIT ROUTE” at exit side of door
Findings:
Passageway to exterior exit with low level illuminated sign lacks tactile exit sign
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ East Exit Stairway S1090
Barrier #: 22C
X Coordinate: N/A
Barrier Area: Stairways
Barrier Type: Sign ‐ Encl Stairway Level
Barrier Description:
Tactile stairway signage not provided to indicate floor level
Rec. Solution: Provide sign
Findings:
No stair level ID sign
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
ICC A117.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 87
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ East Exit Stairway S1090
Barrier #: 22D
X Coordinate: N/A
Barrier Area: Clear Floor Space
Barrier Type: Protruding Object
Barrier Description:
Protruding object in circulation path protrudes more than 4" between 27" and 80" high
Rec. Solution: Remove object or provide detectable warning for the visually impaired
Findings:
Fire riser hose bib protrudes 10" at 42‐1/2" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ East Exit Stairway S1090
Barrier #: 22E
X Coordinate: N/A
Barrier Area: Stairways
Barrier Type: Contrasting Color ‐ ADA
Barrier Description:
No contrasting color on each tread of interior stairway
Rec. Solution: Recommended: Consider providing contrasting color on each tread
Findings:
Treads lack contrasting color defined as 70% contrast
Quantity: LF or TR
Notes:
Barrier Severity: 2 Recommended Cost Est $2,380.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS Advisory 504.4
As‐built : 68
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 88
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ East Exit Stairway S1090
Barrier #: 22F
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Horn/Strobe ‐ Common Use Area
Barrier Description:
No horn/strobes in common use areas
Rec. Solution: Provide strobe in common use area
Findings:
No device provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $5,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702.1
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 1 ‐ East Exit Stairway S1090
Barrier #: 22G
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Tactile Exit Signs ‐ Door
Barrier Description:
Ground floor doors that exit to exterior lacks tactile exit sign
Rec. Solution: Provide sign stating “EXIT” at exit side of door to exterior
Findings:
Exit door with low level illuminated sign lacks tactile exit sign
Quantity: EACH
Notes: No tactile exit sign for exit door to exterior
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 216.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 2 of 8
ADA Assessment and Survey 2014 89
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Open Stairway S2087
Barrier #: 23
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Tactile Exit Signs ‐ Stairway
Barrier Description:
Exit stairway lacks tactile exit sign
Rec. Solution: Provide sign stating “EXIT STAIR DOWN (or UP)” at latch side of door
Findings:
Exit stair with low level illuminated sign lacks tactile exit sign
Quantity: EACH
Notes: Door to exit stair with low level illuminated sign lacks tactile exit sign
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Vestibule V2079
Barrier #: 24A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: ISA ‐ Accessible Entry Door
Barrier Description:
No sign identifying door as accessible where all doors are accessible
Rec. Solution: Provide ISA signs at accessible entrance door
Findings:
No ISA sign at sliding doors to elevator vestibule 2089
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 216.6
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 90
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Vestibule V2079
Barrier #: 24B
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Tactile Exit Signs ‐ Passage
Barrier Description:
Exit thru an exit enclosure/exit passageway lacks tactile exit sign
Rec. Solution: Provide sign stating “EXIT ROUTE” at exit side of door
Findings:
Passageway to exterior exit with low level illuminated sign lacks tactile exit sign
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Vestibule V2079
Barrier #: 24C
X Coordinate: N/A
Barrier Area: Library Facilities
Barrier Type: Vending Machine ‐ High Reach Range
Barrier Description:
Vending machine point of control not at max. 48" high for side reach
Rec. Solution: Contact vendor to obtain replacement
Findings:
Credit card readers 61" high
Quantity: JOB
Notes: 2 card readers
Barrier Severity: 3 Hindrance Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 91
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Vestibule V2079
Barrier #: 24D
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 77‐1/2" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Elevator E2089
Barrier #: 25A
X Coordinate: N/A
Barrier Area: Elevators
Barrier Type: Hall lanterns ‐ Visible at Entry
Barrier Description:
Visual and audible signals not provided at each hoistway entrance to answer calls �
Rec. Solution: Provide hall lanterns visible from outer side of elevator
Findings:
Hall lanterns not visible from outer side of elevator
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $3,675.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 407.2.2.2
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 92
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Elevator E2089
Barrier #: 25B
X Coordinate: N/A
Barrier Area: Elevators
Barrier Type: Doorjamb marking ‐ Not Raised
Barrier Description:
Elevator landing door jamb signage lack raised characters min. of 2" high or Braille
Rec. Solution: Replace door jamb signage
Findings:
No raised star at discharge level
Quantity: EACH
Notes: Both the first floor and second floor are discharge level for this elevator
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 407.2.3.1
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Elevator E2089
Barrier #: 25C
X Coordinate: N/A
Barrier Area: Elevators
Barrier Type: Self‐leveling Device
Barrier Description:
No automatic self‐leveling feature provided to bring landing within +/‐ 1/2"
Rec. Solution: Repair automatic self‐leveling device for existing elevator
Findings:
Car over travel 1" from landing level
Quantity: JOB
Notes:
Barrier Severity: 1 Necessary Cost Est $7,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 407.3.3.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 93
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Elevator E2089
Barrier #: 25D
X Coordinate: N/A
Barrier Area: Elevators
Barrier Type: Door Delay Duration
Barrier Description:
Door reopening devices does not remain effective for 20 seconds minimum
Rec. Solution: Adjust door delay
Findings:
Door delay 2 seconds
Quantity: JOB
Notes:
Barrier Severity: 1 Necessary Cost Est $3,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 407.3.3.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Elevator E2089
Barrier #: 25E
X Coordinate: N/A
Barrier Area: Elevators
Barrier Type: Audible Signals
Barrier Description:
Audible signals or verbal announcement does not sound when the car passes a floor or stops
Rec. Solution: Replace car controls
Findings:
No audible indication of travel at car call lobby
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $2,750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 407.2.2.1
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 94
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Elevator E2089
Barrier #: 25F
X Coordinate: N/A
Barrier Area: Elevators
Barrier Type: Emergency Controls ‐ Cabinet
Barrier Description:
Cabinet housing emergency controls lack accessible hardware
Rec. Solution: Replace cabinet hardware
Findings:
Emergency controls inside car within cabinet that has no handle/hardware on door
Quantity: JOB
Notes:
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 407.4.6.4.1 and 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Main Entrance
Barrier #: 26
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Actuator/Control ‐ Hi/low Reach
Barrier Description:
Use of control involves low reach of less than 15" above floor or more than 48" high
Rec. Solution: Relocate to area at min. 15" or max. 48" high
Findings:
Exterior book drop handle 54" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 308.2.2
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 95
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Entry Lobby L2069
Barrier #: 27A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Permanent Room/Space ‐ Tactile Characters
Barrier Description:
No tactile characters at sign identifying permanent rooms and spaces with visual signs
Rec. Solution: Provide accessible sign
Findings:
Staff entry side door has visual sign but not braille/ tactile sign
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 216.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Entry Lobby L2069
Barrier #: 27B
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: ISA ‐ Accessible Entry Door
Barrier Description:
No sign identifying door as accessible where all doors are accessible
Rec. Solution: Provide ISA signs at accessible entrance door
Findings:
No ISA signs at inner sliding doors where not all doors are accessible
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 216.6
As‐built : 2
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 96
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Entry Lobby L2069
Barrier #: 27C
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Lobby Info Sign
Barrier Description:
No lobby informational sign with location of accessible elements
Rec. Solution: Provide lobby informational sign
Findings:
Accessible sign not provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Entry Lobby L2069
Barrier #: 27D
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Doormat
Barrier Description:
Doormat not anchored to floor (possible trip hazard)
Rec. Solution: Secure exiting doormat or replace
Findings:
Door mat not secured
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 302.2 & Advisory 302.2
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 97
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Entry Lobby L2069
Barrier #: 27E
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Tactile Exit Signs ‐ Door
Barrier Description:
Ground floor doors that exit to exterior lacks tactile exit sign
Rec. Solution: Provide signs stating “EXIT” at exit side of door
Findings:
Exit door with low level illuminated sign lacks tactile exit sign
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 216.4.1
As‐built : 2
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Entry Lobby L2069
Barrier #: 27F
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 77‐1/2" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 98
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Circulation Area 2055
Barrier #: 28A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Permanent Room/Space ‐ Tactile Characters
Barrier Description:
No tactile characters at sign identifying permanent rooms and spaces with visual signs
Rec. Solution: Provide accessible tactile signs
Findings:
Overhead visual signs without braille and tactile information at wall at both entry points to service area
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 216.2
As‐built : 2
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Circulation Area 2055
Barrier #: 28B
X Coordinate: N/A
Barrier Area: Library Facilities
Barrier Type: Protruding Object
Barrier Description:
Protruding object in in circulation path protrudes more than 4" between 27" and 80" high
Rec. Solution: Remove object or provide detectable warning (wing walls)
Findings:
Monitor protrudes 12" at 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 99
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Circulation Area 2055
Barrier #: 28C
X Coordinate: N/A
Barrier Area: Counters and Tables
Barrier Type: Counter ‐ Surface Height
Barrier Description:
No section at least 3 feet long between 28" and 34" provided at existing counters
Rec. Solution: Provide min. 3 ft long section of counters at max. 34" high
Findings:
41‐1/2" high
Quantity: EACH
Notes: 3 circulation service counters
Barrier Severity: 3 Hindrance Cost Est $875.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 902.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Circulation Area 2055
Barrier #: 28D
X Coordinate: N/A
Barrier Area: Counters and Tables
Barrier Type: Counter ‐ Surface Height
Barrier Description:
No section at least 3 feet long between 28" and 34" provided at existing counter
Rec. Solution: Provide min. 3 ft long section of counter at max. 34" high
Findings:
41‐1/2" high
Quantity: EACH
Notes: Computer desk service counter
Barrier Severity: 3 Hindrance Cost Est $875.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 902.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 100
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Circulation Area 2055
Barrier #: 28E
X Coordinate: N/A
Barrier Area: Counters and Tables
Barrier Type: Counter ‐ Surface Height
Barrier Description:
No section at least 3 feet long between 28" and 34" provided at existing counter
Rec. Solution: Provide min. 3 ft long section of counters at max. 34" high for the 3 multimedia service counter
Findings:
Lower counter not provided with staff person where 3 multimedia service counters exist
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $875.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 902.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Circulation Area 2055
Barrier #: 28F
X Coordinate: N/A
Barrier Area: Library Facilities
Barrier Type: Workstation/Study Carrel ‐ Knee Clearance
Barrier Description:
Knee clearance of at least 27" high, 30" wide and 8" deep not provided
Rec. Solution: Provide min. 2 accessible express checkout computer station
Findings:
2 express checkout computer stations have 24" high and 15‐1/2" deep knee clearance
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $875.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 902
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 101
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Circulation Area 2055
Barrier #: 28G
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Visual Information Provided (Exhibitions)
Barrier Description:
Visual sign providing information for program, service or activity not accessible
Rec. Solution: Provide information in alternate format to provide access to people with vision impairments
Findings:
Cow sculpture lacks information for visually impaired
Quantity: JOB
Notes:
Barrier Severity: 1 Necessary Cost Est $5,000.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
ADA Title II Technical Assistance Manual 3.2000 Denial of participation
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Central Corridor H2000
Barrier #: 29A
X Coordinate: N/A
Barrier Area: Corridors
Barrier Type: Sign ‐ Tactile Location 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
41‐3/4" and 62" high at rooms 2021 and 2035
Quantity: EACH
Notes: Also, braille not 3/8" and max. 1/2" directly below the tactile characters and braille dots on sign not domed or rounded
Barrier Severity: 1 Necessary Cost Est $500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 2
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 102
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Central Corridor H2000
Barrier #: 29B
X Coordinate: N/A
Barrier Area: Corridors
Barrier Type: Sign ‐ Truncated Dots
Barrier Description:
Braille dots on sign not domed or rounded
Rec. Solution: Replace signs
Findings:
Accessible sign not provided
Quantity: EACH
Notes: Also, Braille not 3/8" and max. 1/2" directly below the tactile characters, Braille dots on sign not domed or rounded and Braille is not contracted Grade 2
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.3
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Central Corridor H2000
Barrier #: 29C
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Visual Information Provided (Exhibitions)
Barrier Description:
Visual sign providing information for program, service or activity not accessible
Rec. Solution: Provide information in alternate format to provide access to people with vision impairments
Findings:
3 artworks exhibited lack descriptions for the visually impaired
Quantity: JOB
Notes:
Barrier Severity: 1 Necessary Cost Est $5,000.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
ADA Title II Technical Assistance Manual 3.2000 Denial of participation
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 103
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Central Corridor H2000
Barrier #: 29D
X Coordinate: N/A
Barrier Area: Clear Floor Space
Barrier Type: Clear Floor Space ‐ Wheelchair Use
Barrier Description:
Clear floor space of min. 30" by 48" not provided
Rec. Solution: Move stored items at control or mechanism
Findings:
Cart blocks accessible library catalogue PC workstation clear floor space
Quantity: JOB
Notes: 5 library catalogue PC workstations with one lower accessible counter
Barrier Severity: 1 Necessary Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305
As‐built : 0
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Central Corridor H2000
Barrier #: 29E
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Electrical Outlets ‐ Hi/Low Reach
Barrier Description:
Use of outlet involves low reach of less than 15" above floor or more than 48" high
Rec. Solution: Relocate outlet to area at min. 15" or max. 48" high
Findings:
14‐1/2" high
Quantity: EACH
Notes: 3 electrical outlets at corridor
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 308.2.2
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 104
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Central Corridor H2000
Barrier #: 29F
X Coordinate: N/A
Barrier Area: Corridors
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobes
Findings:
Strobes mounted 77‐1/2" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $2,200.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 4
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Elevator E2041A
Barrier #: 30A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Lobby Info Sign
Barrier Description:
No lobby informational sign with location on accessible elements
Rec. Solution: Recommended: Provide lobby informational sign
Findings:
Accessible sign not provided at elevator lobby
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 105
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Elevator E2041A
Barrier #: 30B
X Coordinate: N/A
Barrier Area: Elevators
Barrier Type: Hall Call Buttons ‐ 42" High
Barrier Description:
The centerline of the hall call buttons not max. 42" above the floor
Rec. Solution: Replace hall call buttons
Findings:
42‐1/2" high on center
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $3,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 407.2.1
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Elevator E2041A
Barrier #: 30C
X Coordinate: N/A
Barrier Area: Elevators
Barrier Type: Doorjamb marking ‐ Not Raised
Barrier Description:
Elevator landing door jamb signage lack raised characters min. of 2" high or Braille
Rec. Solution: Replace door jamb signage
Findings:
No raised star at discharge level
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 407.2.3.1
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 106
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Elevator E2041A
Barrier #: 30D
X Coordinate: N/A
Barrier Area: Elevators
Barrier Type: Hall lanterns ‐ Visible at Entry
Barrier Description:
Visual and audible signals not provided at each hoistway entrance to answer calls �
Rec. Solution: Provide hall lanterns visible from outer side of elevator
Findings:
Hall lanterns or audible signals not provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $3,675.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 407.2.2.2
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Elevator E2041A
Barrier #: 30E
X Coordinate: N/A
Barrier Area: Elevators
Barrier Type: Door Delay Duration
Barrier Description:
Door reopening devices does not remain effective for 20 seconds minimum
Rec. Solution: Adjust door delay
Findings:
Door delay 2 seconds
Quantity: JOB
Notes:
Barrier Severity: 1 Necessary Cost Est $3,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 407.3.3.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 107
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Elevator E2041A
Barrier #: 30F
X Coordinate: N/A
Barrier Area: Elevators
Barrier Type: Audible Signals
Barrier Description:
Audible signals or verbal announcement does not sound when the car passes a floor or stops
Rec. Solution: Replace car controls
Findings:
No audible indication of travel at car call lobby
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $2,750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 407.2.2.1
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Elevator E2041A
Barrier #: 30G
X Coordinate: N/A
Barrier Area: Elevators
Barrier Type: Emergency Controls ‐ 2‐way
Barrier Description:
Emergency two‐way communication system not provided
Rec. Solution: Replace emergency system
Findings:
Emergency controls inside car function to call police but lights indicating function do not illuminate
Quantity: JOB
Notes:
Barrier Severity: 1 Necessary Cost Est $3,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 407.4.9 and ASME A17.1
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 108
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Elevator E2041A
Barrier #: 30H
X Coordinate: N/A
Barrier Area: Elevators
Barrier Type: 4+ Story Bldgs ‐ Emergency Access
Barrier Description:
Min. one car in building of more than 4 stories lacks 24" x 84" space for ambulance stretcher
Rec. Solution: Provide emergency elevator
Findings:
Elevator designated as medical emergency elevator with only 64" deep
Quantity: JOB
Notes:
Barrier Severity: 1 Necessary Cost Est $200,000.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Elevator E2041B
Barrier #: 31A
X Coordinate: N/A
Barrier Area: Elevators
Barrier Type: Hall Call Buttons ‐ 42" High
Barrier Description:
The centerline of the hall call buttons not max. 42" above the floor
Rec. Solution: Replace hall call buttons
Findings:
42‐1/2" high on center
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $3,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 407.2.1
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 109
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Elevator E2041B
Barrier #: 31B
X Coordinate: N/A
Barrier Area: Elevators
Barrier Type: Doorjamb marking ‐ Not Raised
Barrier Description:
Elevator landing door jamb signage lack raised characters min. of 2" high or Braille
Rec. Solution: Replace door jamb signage
Findings:
No raised star at discharge level
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 407.2.3.1
As‐built : 2
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Elevator E2041B
Barrier #: 31C
X Coordinate: N/A
Barrier Area: Elevators
Barrier Type: Hall lanterns ‐ Visible at Entry
Barrier Description:
Visual and audible signals not provided at each hoistway entrance to answer calls �
Rec. Solution: Provide hall lanterns visible from outer side of elevator
Findings:
Hall lanterns or audible signals not provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $3,675.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 407.2.2.2
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 110
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Elevator E2041B
Barrier #: 31D
X Coordinate: N/A
Barrier Area: Elevators
Barrier Type: Door Delay Duration
Barrier Description:
Door reopening devices does not remain effective for 20 seconds minimum
Rec. Solution: Adjust door delay
Findings:
Door delay 2 seconds
Quantity: JOB
Notes:
Barrier Severity: 1 Necessary Cost Est $3,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 407.3.3.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Elevator E2041B
Barrier #: 31E
X Coordinate: N/A
Barrier Area: Elevators
Barrier Type: Audible Signals
Barrier Description:
Audible signals or verbal announcement does not sound when the car passes a floor or stops
Rec. Solution: Replace car controls
Findings:
No audible indication of travel at car call lobby
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $2,750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 407.2.2.1
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 111
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Elevator E2041B
Barrier #: 31F
X Coordinate: N/A
Barrier Area: Elevators
Barrier Type: Emergency Controls ‐ 2‐way
Barrier Description:
Emergency two‐way communication system not provided
Rec. Solution: Replace emergency system
Findings:
Emergency controls inside car function to call police but lights indicating function do not illuminate
Quantity: JOB
Notes:
Barrier Severity: 1 Necessary Cost Est $3,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 407.4.9 and ASME A17.1
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ West Exit Stairway S2010
Barrier #: 32A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Tactile Exit Signs ‐ Stairway
Barrier Description:
Door leading directly into an exit stairway lacks tactile exit sign
Rec. Solution: Provide sign stating “EXIT STAIR DOWN (or UP)” at latch side of door
Findings:
No tactile exit sign at entry doorway to stairs (entry doors held open)
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 112
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ West Exit Stairway S2010
Barrier #: 32B
X Coordinate: N/A
Barrier Area: Stairways
Barrier Type: Sign ‐ Encl Stairway Level
Barrier Description:
Tactile stairway signage not provided to indicate floor level
Rec. Solution: Provide sign
Findings:
No stair level ID sign
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
ICC A117.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ West Exit Stairway S2010
Barrier #: 32C
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Tactile Exit Signs ‐ Door
Barrier Description:
Ground floor doors that exit to exterior lacks tactile exit sign
Rec. Solution: Provide sign stating “EXIT” at exit side of door
Findings:
No tactile exit sign at exit door to exterior
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 216.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 113
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ West Exit Stairway S2010
Barrier #: 32D
X Coordinate: N/A
Barrier Area: Clear Floor Space
Barrier Type: Protruding Object
Barrier Description:
Protruding object in circulation path protrudes more than 4" between 27" and 80" high
Rec. Solution: Remove object or provide detectable warning for the visually impaired
Findings:
Fire riser hose bib protrudes 14" at 45" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ West Exit Stairway S2010
Barrier #: 32E
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Horn/Strobe ‐ Common Use Area
Barrier Description:
No horn/strobes in common use areas
Rec. Solution: Provide strobe in common use area
Findings:
No device provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $5,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702.1
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 114
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Photocopy Center 2024
Barrier #: 33A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Permanent Room/Space ‐ Tactile Characters
Barrier Description:
No tactile characters at sign identifying permanent rooms and spaces with visual signs
Rec. Solution: Provide accessible sign
Findings:
Overhead visual sign without braille and tactile information at wall at entry point
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 216.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Photocopy Center 2024
Barrier #: 33B
X Coordinate: N/A
Barrier Area: Corridors
Barrier Type: Lockers ‐ Ratio
Barrier Description:
No accessible locker provided
Rec. Solution: Provide min. 1 accessible locker or 5% overall
Findings:
8 lockers and none are accessible
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $450.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 803
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 115
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Photocopy Center 2024
Barrier #: 33C
X Coordinate: N/A
Barrier Area: Corridors
Barrier Type: Lockers ‐ Control
Barrier Description:
Locker mechanism not operable with fist or involves turning and grasping
Rec. Solution: Provide min. 1 accessible locker
Findings:
Lock mechanisms not accessible
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 803.5
As‐built : 0
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Photocopy Center 2024
Barrier #: 33D
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Fare Vending Machines ‐ Braille
Barrier Description:
Machine controls lack raised characters or braille for the visually impaired
Rec. Solution: Provide Braille and raised characters at controls
Findings:
Machine may not be usable for the visuallyimapired. No audible controls provided
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $350.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 308 and 702
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 116
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Photocopy Center 2024
Barrier #: 33E
X Coordinate: N/A
Barrier Area: Library Facilities
Barrier Type: Vending Machine ‐ High Reach Range
Barrier Description:
Vending machine point of control not at max. 48" high for side reach
Rec. Solution: Contact vendor to obtain replacement
Findings:
Card vending machine controls 51" high
Quantity: JOB
Notes:
Barrier Severity: 3 Hindrance Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 0
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Photocopy Center 2024
Barrier #: 33F
X Coordinate: N/A
Barrier Area: Counters and Tables
Barrier Type: Counter ‐ Surface Height
Barrier Description:
No section at least 3 feet long between 28" and 34" provided at existing counter
Rec. Solution: Provide min. 1 accessible work counter at max. 34" high
Findings:
Work counters for use at copy center 36" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $875.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 902.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 117
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Photocopy Center 2024
Barrier #: 33G
X Coordinate: N/A
Barrier Area: Library Facilities
Barrier Type: Clear Floor Space
Barrier Description:
Clear floor space for wheelchair not provided at control or mechanism
Rec. Solution: Move card reader to accessible location
Findings:
Access to card readers needed to operate copier machines not provided
Quantity: SF
Notes:
Barrier Severity: 3 Hindrance Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 0
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Photocopy Center 2024
Barrier #: 33H
X Coordinate: N/A
Barrier Area: Library Facilities
Barrier Type: Actuator/Control ‐ Side Reach Obstructed (10"‐24")
Barrier Description:
Control or mechanism over an 10" to 24" obstruction max. 34" high located above 46"
Rec. Solution: Provide min. 1 accessible scanner
Findings:
Scanner control displays 50" high and 16" deep
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 118
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Photocopy Center 2024
Barrier #: 33I
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 77‐1/2" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Microcomputer Area 2062
Barrier #: 34A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Permanent Room/Space ‐ Tactile Characters
Barrier Description:
No tactile characters at sign identifying permanent rooms and spaces with visual signs
Rec. Solution: Provide accessible sign
Findings:
Overhead visual sign without braille and tactile information at wall at entry point
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 216.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 119
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Microcomputer Area 2062
Barrier #: 34B
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Lockers ‐ Control
Barrier Description:
Locker mechanism not operable with fist or involves turning and grasping
Rec. Solution: Provide min. 1 accessible locker
Findings:
16 lockers and none are accessible. Lock mechanisms not accessible
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 803.5
As‐built : 0
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Microcomputer Area 2062
Barrier #: 34C
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Electrical Outlets ‐ Side Reach Obstructed (10"‐24")
Barrier Description:
Outlet located over an 10" to 24" obstruction max. 34" high located above 46"
Rec. Solution: Relocate control or mechanism to max. 46" high
Findings:
28" deep over a 31" high at accessible patron computer station
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 120
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Microcomputer Area 2062
Barrier #: 34D
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Electrical Outlets ‐ Side Reach Obstructed (10"‐24")
Barrier Description:
Outlet located over an 10" to 24" obstruction max. 34" high located above 46"
Rec. Solution: Relocate controls or mechanisms to max. 46" high
Findings:
Electrical outlets (power strips) hanging below work surface at back of carrels
Quantity: EACH
Notes: 72 Computer study carrels provided with accessible knee clearance but electrical outlets (power strips) hang below work surface at back of carrels
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Microcomputer Area 2062
Barrier #: 34E
X Coordinate: N/A
Barrier Area: Library Facilities
Barrier Type: Workstation/Study Carrel ‐ Ratio
Barrier Description:
At least 1 workstation/carrel or 5% of all workstations/carrels are not accessible
Rec. Solution: Provide min. 1 accessible workstation
Findings:
18 non‐accessible computer stations with circular 6 seats configuration not accessible
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $875.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 902
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 121
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Microcomputer Area 2062
Barrier #: 34F
X Coordinate: N/A
Barrier Area: Library Facilities
Barrier Type: Workstation/Study Carrel ‐ Ratio
Barrier Description:
At least 1 workstation/carrel or 5% of all workstations/carrels are not accessible
Rec. Solution: Provide at least 1 accessible workstations
Findings:
28 Mac stations in zig‐zag configuration lack accessible knee clearance
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $1,750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 902
As‐built : 2
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Microcomputer Area 2062
Barrier #: 34G
X Coordinate: N/A
Barrier Area: Library Facilities
Barrier Type: Vending Machine ‐ High Reach Range
Barrier Description:
Vending machine point of control not at max. 48" high for side reach
Rec. Solution: Contact vendor to obtain replacement
Findings:
Vending machine controls 51" high
Quantity: JOB
Notes:
Barrier Severity: 3 Hindrance Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 122
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Microcomputer Area 2062
Barrier #: 34H
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 77‐1/2" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Stairway S2710
Barrier #: 35A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Braille ‐ Grade 2
Barrier Description:
Contracted (Grade 2) Braille not used on sign
Rec. Solution: Provide accessible sign
Findings:
Existing sign at stairway not accessible
Quantity: EACH
Notes: Also, braille dots on sign not domed or rounded
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.3
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 123
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Stairway S2710
Barrier #: 35B
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Tactile Exit Signs ‐ Stairway
Barrier Description:
Door leading directly into an exit stairway lacks tactile exit sign
Rec. Solution: Provide sign stating “EXIT STAIR DOWN (or UP)” at latch side of door
Findings:
Door to exit stair with low level illuminated sign lacks tactile exit sign. Existing sign states "STAIR"
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Collaborative Learning Center West
Barrier #: 36A
X Coordinate: N/A
Barrier Area: Counters and Tables
Barrier Type: Table ‐ Ratio
Barrier Description:
At least 1 table or 5% of all tables are not accessible
Rec. Solution: Provide at least 1 accessible table of each type but 5% overall
Findings:
31 total pedestal based tables. None have accessible knee clearance
Quantity: EACH
Notes: Table type 1 has 26‐1/2" high knee clearance, 9 tables type 2 with 25" high knee clearance. 2 longer group desks were accessible
Barrier Severity: 3 Hindrance Cost Est $1,800.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 902
As‐built : 4
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 124
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Collaborative Learning Center West
Barrier #: 35B
X Coordinate: N/A
Barrier Area: Library Facilities
Barrier Type: Table ‐ Pedestal Base
Barrier Description:
Knee clearance not min. 27" high, 19" deep or 30" wide
Rec. Solution: Provide at least 2 accessible tables. Avoid pedestal base tables
Findings:
Pedestal base block knee clearance
Quantity: EACH
Notes: 31 pedestal based tables
Barrier Severity: 2 Recommended Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 306.2.2 and 306.2.3
As‐built : 0
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Collaborative Learning Center West
Barrier #: 35C
X Coordinate: N/A
Barrier Area: Library Facilities
Barrier Type: Table ‐ Knee Clearance
Barrier Description:
Knee clearance not min. 27" high, 19" deep or 30" wide
Rec. Solution: Provide min. 1 accessible table
Findings:
26‐1/2" high knee clearance
Quantity: EACH
Notes: 1 ‐‐ Table type 1
Barrier Severity: 3 Hindrance Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 0
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 125
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Collaborative Learning Center West
Barrier #: 35D
X Coordinate: N/A
Barrier Area: Library Facilities
Barrier Type: Table ‐ Knee Clearance
Barrier Description:
Knee clearance not min. 27" high, 19" deep or 30" wide
Rec. Solution: Provide min. 1 accessible table
Findings:
25" high knee clearance
Quantity: EACH
Notes: 9 ‐‐ Table type 2
Barrier Severity: 3 Hindrance Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 0
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Collaborative Learning Center West
Barrier #: 35E
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ Existing
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobes
Findings:
Strobes mounted 77‐1/2" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $1,650.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 3
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 126
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Loading Dock Room 2711
Barrier #: 36A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61" high
Quantity: EACH
Notes: Also, braille not 3/8" and max. 1/2" directly below the tactile characters, braille on sign not located directly below tactile characters and braille dots on sign not domed or rounded
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Loading Dock Room 2711
Barrier #: 36B
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Electrical Switches ‐ Height
Barrier Description:
Light switch control box top edge not at max. 48" high
Rec. Solution: Relocate switch box top edge to max. 48" high
Findings:
50‐1/2" high
Quantity: EACH
Notes: Not part of the assessment but elevator 3 is inside this room. Staffs enter through this space and use the elevator
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 308.2
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 127
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Loading Dock Room 2711
Barrier #: 36C
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ Existing
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Elevator 3 E2711
Barrier #: 37A
X Coordinate: N/A
Barrier Area: Clear Floor Space
Barrier Type: Carpet/Rug
Barrier Description:
Carpet/rug not anchored to floor (possible trip hazard)
Rec. Solution: Secure exiting carpet/rugs or replace
Findings:
Carpet/rugs create tripping hazard
Quantity: EACH
Notes: Mats at elevator door landing and inside elevator
Barrier Severity: 1 Necessary Cost Est $1,000.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 302.2
As‐built : 2
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 128
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Elevator 3 E2711
Barrier #: 37B
X Coordinate: N/A
Barrier Area: Elevators
Barrier Type: Hall Call Buttons ‐ 42" High
Barrier Description:
The centerline of the hall call buttons not max. 42" above the floor
Rec. Solution: Replace hall call buttons
Findings:
43" high on center
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $3,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 407.2.1
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Elevator 3 E2711
Barrier #: 37C
X Coordinate: N/A
Barrier Area: Elevators
Barrier Type: Hall lanterns ‐ Audible Direction
Barrier Description:
Audible signal does not sound once for the up direction and twice for the down direction
Rec. Solution: Replace hall lanterns
Findings:
No audible indication of travel at hall call lobby
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $3,675.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 407.2.2.2
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 129
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Elevator 3 E2711
Barrier #: 37D
X Coordinate: N/A
Barrier Area: Elevators
Barrier Type: Hall lanterns ‐ Visible at Entry
Barrier Description:
Visual and audible signals not provided at each hoistway entrance to answer calls �
Rec. Solution: Provide hall lanterns visible from outer side of elevator
Findings:
Hall lanterns not illuminate from outer side of elevator
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $3,675.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 407.2.2.2
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Elevator 3 E2711
Barrier #: 37E
X Coordinate: N/A
Barrier Area: Elevators
Barrier Type: Emergency Sign at Call Station
Barrier Description:
Sign stating "IN FIRE EMERGENCY, DO NOT USE ELEVATOR. USE EXIT STAIRS" not provided with tactile information
Rec. Solution: No tactile information on sign
Findings:
Evacuation sign has braille at side of floor number
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard & 2010 ADAS 703.1
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 130
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Elevator 3 E2711
Barrier #: 37F
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Braille ‐ Truncated Dots
Barrier Description:
Braille dots on sign not domed or rounded
Rec. Solution: Provide accessible sign
Findings:
Accessible sign not provided
Quantity: EACH
Notes: Fire evacuation braille sign is truncated
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.3
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Elevator 3 E2711
Barrier #: 37G
X Coordinate: N/A
Barrier Area: Elevators
Barrier Type: Door Delay Duration
Barrier Description:
Door reopening devices does not remain effective for 20 seconds minimum
Rec. Solution: Adjust door delay
Findings:
Door delay 2 seconds
Quantity: JOB
Notes:
Barrier Severity: 1 Necessary Cost Est $3,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 407.3.3.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 131
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Elevator 3 E2711
Barrier #: 37H
X Coordinate: N/A
Barrier Area: Elevators
Barrier Type: Audible Signals
Barrier Description:
Audible signals or verbal announcement does not sound when the car passes a floor or stops
Rec. Solution: Replace car controls
Findings:
No audible indication of travel inside elevator
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $2,750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 407.2.2.1
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Elevator 3 E2711
Barrier #: 37I
X Coordinate: N/A
Barrier Area: Elevators
Barrier Type: Hall Call Buttons ‐ Registration
Barrier Description:
Visual indication not provided to show each call registered and extinguished when answered
Rec. Solution: Replace hall call buttons
Findings:
No audible controls in hall call area
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $3,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 407.2.1.5
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 132
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Elevator 3 E2711
Barrier #: 37J
X Coordinate: N/A
Barrier Area: Elevators
Barrier Type: Audible Signals
Barrier Description:
Audible signals or verbal announcement does not sound when the car passes a floor or stops
Rec. Solution: Replace car controls
Findings:
No audible controls inside elevator
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 407.2.2.1
As‐built : 0
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Elevator 3 E2711
Barrier #: 37K
X Coordinate: N/A
Barrier Area: Elevators
Barrier Type: Emergency Controls ‐ Cabinet
Barrier Description:
Cabinet housing emergency controls lack accessible hardware
Rec. Solution: Replace cabinet hardware
Findings:
Emergency controls inside car within cabinet that has no handle/hardware on door
Quantity: JOB
Notes:
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 407.4.6.4.1 and 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 133
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Elevator 3 E2711
Barrier #: 37L
X Coordinate: N/A
Barrier Area: Elevators
Barrier Type: Emergency Controls ‐ 2‐way
Barrier Description:
Emergency two‐way communication system not provided
Rec. Solution: Replace emergency system
Findings:
Emergency controls inside car function to call police but lights indicating function do not illuminate
Quantity: JOB
Notes:
Barrier Severity: 1 Necessary Cost Est $3,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 407.4.9 and ASME A17.1
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Collaborative Learning Center East
Barrier #: 38A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
62‐1/4" high at room 2771
Quantity: EACH
Notes: Also, braille dots on sign not domed or rounded
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 134
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Collaborative Learning Center East
Barrier #: 38B
X Coordinate: N/A
Barrier Area: Clear Floor Space
Barrier Type: Passageway ‐ Min. 36"
Barrier Description:
Circulation route not min. 36" wide between elements
Rec. Solution: Remove cubicle wall to provide emergency egress
Findings:
Cubicle wall blocks exit path to exit doors. No exit door to exterior
Quantity: LF
Notes:
Barrier Severity: 1 Necessary Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 403.5.1
As‐built : 0
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Collaborative Learning Center East
Barrier #: 38C
X Coordinate: N/A
Barrier Area: Counters and Tables
Barrier Type: Counter ‐ Surface Height
Barrier Description:
No section at least 3 feet long between 28" and 34" provided at existing counter
Rec. Solution: Provide min. 3 ft long section of counters at max. 34" high
Findings:
2 service counters at 35" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $875.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 902.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 135
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Collaborative Learning Center East
Barrier #: 38D
X Coordinate: N/A
Barrier Area: Library Facilities
Barrier Type: Electrical Outlets ‐ Hi/Low Reach
Barrier Description:
Use of outlet involves low reach of less than 15" above floor or more than 48" high
Rec. Solution: Relocate outlet to area at min. 15" or max. 48" high
Findings:
14" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 308.2.2
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Collaborative Learning Center East
Barrier #: 38E
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ Existing
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobes
Findings:
Strobes mounted 77‐1/2" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $1,650.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 3
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 136
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Exit Stairway S2790
Barrier #: 39A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Tactile Exit Signs ‐ Stairway
Barrier Description:
Door leading directly into an exit stairway lacks tactile exit sign
Rec. Solution: Provide sign stating “EXIT STAIR DOWN (or UP)” at latch side of door
Findings:
Door to exit stair with low level illuminated sign lacks tactile exit sign. Existing sign states "STAIR"
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Exit Stairway S2790
Barrier #: 39B
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Interior Adjustment
Barrier Description:
Door opening force exceeds 5 lbf
Rec. Solution: Replace or adjust existing closers. Door does not lead to an accessible route
Findings:
17 lbf at entry doors to stairway and 19 lbf at door to exterior
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $1,350.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.9
As‐built : 3
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 137
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Exit Stairway S2790
Barrier #: 39C
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Interior Sweep Period
Barrier Description:
Door closer lacks min. 5 second sweep period or does not stop 5" from door frame
Rec. Solution: Replace or adjust existing closers. Door does not lead to an accessible route
Findings:
3 second sweep at all 3 doors within stairway
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.8.1
As‐built : 3
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Exit Stairway S2790
Barrier #: 39D
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Horn/Strobe ‐ Common Use Area
Barrier Description:
No horn/strobes in common use areas
Rec. Solution: Provide strobe in common use area
Findings:
No device provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $5,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702.1
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 138
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Elevator/Restroom Corridor H2500
Barrier #: 40A
X Coordinate: N/A
Barrier Area: Corridors
Barrier Type: Sign ‐ Permanent Room/Space
Barrier Description:
No sign with raised characters and Braille at permanent room or space with visual sign
Rec. Solution: Provide sign at latch side of entry door, where possible
Findings:
Overhead visual sign info not provided in tactile signage at doorway within public route
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Elevator/Restroom Corridor H2500
Barrier #: 40B
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Sign ‐ Truncated Dots
Barrier Description:
Braille dots on sign not domed or rounded
Rec. Solution: Replace sign
Findings:
Accessible sign not provided at room 2567
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.3
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 139
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Elevator/Restroom Corridor H2500
Barrier #: 40C
X Coordinate: N/A
Barrier Area: Drinking Fountains
Barrier Type: Alcove ‐ New Construction
Barrier Description:
Fountain with a leading edge between 27" and 80" high protrudes more than 4" into the circulation path
Rec. Solution: Demolish and construct new alcove as detectable warning
Findings:
Hi‐Low drinking fountain not completely inside alcove
Quantity: SF
Notes:
Barrier Severity: 1 Necessary Cost Est $2,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307.2
As‐built : 10
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Elevator/Restroom Corridor H2500
Barrier #: 40D
X Coordinate: N/A
Barrier Area: Drinking Fountains
Barrier Type: Operation ‐ Replacement
Barrier Description:
Operating mechanism involves more than 5 lbf to operate
Rec. Solution: Replace drinking fountain with accessible unit
Findings:
Needed more than 5 lbf where fountain is not adjustable
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 602.3
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 140
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Elevator/Restroom Corridor H2500
Barrier #: 40E
X Coordinate: N/A
Barrier Area: Corridors
Barrier Type: Strobe Height ‐ 80" on Wall
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Elevator 2 E2568
Barrier #: 41A
X Coordinate: N/A
Barrier Area: Elevators
Barrier Type: Hall lanterns ‐ Visible at Entry
Barrier Description:
Visual and audible signals not provided at each hoistway entrance to answer calls �
Rec. Solution: Provide hall lanterns visible from outer side of elevator
Findings:
Hall lanterns not illuminate from outer side of elevator
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $3,675.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 407.2.2.2
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 141
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Elevator 2 E2568
Barrier #: 41B
X Coordinate: N/A
Barrier Area: Elevators
Barrier Type: Hall lanterns ‐ Audible Direction
Barrier Description:
Audible signal does not sound once for the up direction and twice for the down direction
Rec. Solution: Replace hall lanterns
Findings:
No audible signals at hall call button area
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $3,675.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 407.2.2.2
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Elevator 2 E2568
Barrier #: 41C
X Coordinate: N/A
Barrier Area: Elevators
Barrier Type: Door Delay Duration
Barrier Description:
Door reopening devices does not remain effective for 20 seconds minimum
Rec. Solution: Adjust door delay
Findings:
Door delay 4 seconds
Quantity: JOB
Notes:
Barrier Severity: 1 Necessary Cost Est $3,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 407.3.3.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 142
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Elevator 2 E2568
Barrier #: 41D
X Coordinate: N/A
Barrier Area: Elevators
Barrier Type: Car Control Buttons ‐ Illumination
Barrier Description:
Visual floor buttons do not illuminate as the car passes floors or stops
Rec. Solution: Replace car controls
Findings:
Car control buttons do not remain illuminated after being actuated
Quantity: EACH
Notes: After button for floor 4 is actuated, all other buttons cancel their calls
Barrier Severity: 2 Recommended Cost Est $2,750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 407.4.8
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Elevator 2 E2568
Barrier #: 41E
X Coordinate: N/A
Barrier Area: Elevators
Barrier Type: Emergency Controls ‐ 2‐way
Barrier Description:
Emergency two‐way communication system not provided
Rec. Solution: Replace emergency system
Findings:
Emergency communication system does not work properly
Quantity: JOB
Notes: Button is frozen and cannot be actuated
Barrier Severity: 1 Necessary Cost Est $3,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 407.4.9 and ASME A17.1
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 143
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Elevator 1 E2568
Barrier #: 42A
X Coordinate: N/A
Barrier Area: Elevators
Barrier Type: Hall lanterns ‐ Visible at Entry
Barrier Description:
Visual and audible signals not provided at each hoistway entrance to answer calls �
Rec. Solution: Provide hall lanterns visible from outer side of elevator
Findings:
Hall lanterns not illuminate from outer side of elevator
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $3,675.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 407.2.2.2
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Elevator 1 E2568
Barrier #: 42B
X Coordinate: N/A
Barrier Area: Elevators
Barrier Type: Hall lanterns ‐ Audible Direction
Barrier Description:
Audible signal does not sound once for the up direction and twice for the down direction
Rec. Solution: Replace hall lanterns
Findings:
No audible signals at hall call button area
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $3,675.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 407.2.2.2
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 144
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Elevator 1 E2568
Barrier #: 42C
X Coordinate: N/A
Barrier Area: Elevators
Barrier Type: Doorjamb marking ‐ Height
Barrier Description:
Elevator landing door jamb signage not located 60" on center on both jamb panels
Rec. Solution: Replace door jamb signage
Findings:
60‐1/2" high on center
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 407.2.3.1
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Elevator 1 E2568
Barrier #: 42D
X Coordinate: N/A
Barrier Area: Elevators
Barrier Type: Door Delay Duration
Barrier Description:
Door reopening devices does not remain effective for 20 seconds minimum
Rec. Solution: Adjust door delay
Findings:
Door delay 4 seconds
Quantity: JOB
Notes:
Barrier Severity: 1 Necessary Cost Est $3,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 407.3.3.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 145
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Elevator 1 E2568
Barrier #: 42E
X Coordinate: N/A
Barrier Area: Elevators
Barrier Type: Car Control Buttons ‐ Illumination
Barrier Description:
Visual floor buttons do not illuminate as the car passes floors or stops
Rec. Solution: Replace car controls
Findings:
Car control buttons do not remain illuminated after being actuated
Quantity: EACH
Notes: After button for floor 4 is actuated, all other buttons cancel their calls, the door opens and an alarm goes off
Barrier Severity: 2 Recommended Cost Est $2,750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 407.4.8
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Elevator 1 E2568
Barrier #: 42F
X Coordinate: N/A
Barrier Area: Elevators
Barrier Type: Emergency Controls ‐ 2‐way
Barrier Description:
Emergency two‐way communication system not provided
Rec. Solution: Replace emergency system
Findings:
Emergency communication system does not work properly
Quantity: JOB
Notes: Button can be actuated but lights indicating activation do not illuminate. A call was registered by equipment with a delay of 2 minutes
Barrier Severity: 1 Necessary Cost Est $3,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 407.4.9 and ASME A17.1
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 3 of 8
ADA Assessment and Survey 2014 146
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Men's Restroom 2569
Barrier #: 43A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
62" high
Quantity: EACH
Notes: Also, Braille not 3/8" and max. 1/2" directly below the tactile characters and Braille dots on sign not domed or rounded
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Men's Restroom 2569
Barrier #: 43B
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Interior
Barrier Description:
Door opening force exceeds 5 lbf
Rec. Solution: Provide automatic door opening device
Findings:
15 lbf
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $5,000.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.9
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
ADA Assessment and Survey 2014 147
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Men's Restroom 2569
Barrier #: 43C
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Sweep Period
Barrier Description:
Door closer lacks min. 5 second sweep period
Rec. Solution: Provide automatic door opening device
Findings:
2 second sweep
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.8.1
As‐built : 0
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Men's Restroom 2569
Barrier #: 43D
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Dispensers ‐ Protruding Object
Barrier Description:
Protruding dispenser creates protruding hazard in path of travel
Rec. Solution: Remove dispenser or provide detectable warning for the visually impaired
Findings:
Paper towel dispenser protrudes 10" at 44" high. Dryer protrudes 6" at 44" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $1,100.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307.2
As‐built : 2
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
ADA Assessment and Survey 2014 148
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Men's Restroom 2569
Barrier #: 43E
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Lavatory ‐ Rim Height
Barrier Description:
Lavatory rim or counter edge is higher than 34" AFF
Rec. Solution: Provide min. 1 accessible lavatory
Findings:
34‐1/2" high AFF
Quantity: JOB
Notes:
Barrier Severity: 1 Necessary Cost Est $450.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 606.3
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Men's Restroom 2569
Barrier #: 43F
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Lavatory ‐ Knee Clearance
Barrier Description:
Lavatory bottom apron/edge not max 29" reducing to 27" at 8" back from edge
Rec. Solution: Remove cover on drainpipes
Findings:
7‐1/2" deep knee clearance at 27" high
Quantity: JOB
Notes:
Barrier Severity: 1 Necessary Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 606.2 & 306
As‐built : 0
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
ADA Assessment and Survey 2014 149
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Men's Restroom 2569
Barrier #: 43G
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Electrical Outlets ‐ Forward Reach Obstructed (10"‐25")
Barrier Description:
Outlet located over an 10" to 25" obstruction max. 34" high located above 44"
Rec. Solution: Relocate control or mechanism to max. 44" high
Findings:
44" high and 22" deep over an obstruction 34" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 308.2.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Men's Restroom 2569
Barrier #: 43H
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Urinal ‐ Rim
Barrier Description:
Min. 1 urinal has no elongated rim projecting 14" to 17" from wall
Rec. Solution: Provide min. 1 accessible urinal
Findings:
13" deep
Quantity: JOB
Notes:
Barrier Severity: 2 Recommended Cost Est $800.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 605.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
ADA Assessment and Survey 2014 150
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Men's Restroom 2569
Barrier #: 43I
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Stall Door Closer
Barrier Description:
Stall door not equipped with an automatic closing device
Rec. Solution: Replace compartment hinge with adjustible mechanism
Findings:
Stall door not self‐closing
Quantity: JOB
Notes:
Barrier Severity: 2 Recommended Cost Est $1,650.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.8.1.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Men's Restroom 2569
Barrier #: 43J
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Stall ‐ Door Hardware
Barrier Description:
Outside of compartment door lacks a loop or U‐pull below latch
Rec. Solution: Provide hardware
Findings:
No U‐pull provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $75.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.8.1.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
ADA Assessment and Survey 2014 151
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Men's Restroom 2569
Barrier #: 43K
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Stall ‐ Door Hardware
Barrier Description:
Inside of compartment door lacks a loop or U‐pull below latch
Rec. Solution: Provide hardware
Findings:
No U‐pull provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $75.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.8.1.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Men's Restroom 2569
Barrier #: 43L
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Coat Hook
Barrier Description:
Clothing hooks not max. 48" high AFF
Rec. Solution: Provide additional hook in new location
Findings:
52" high
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $125.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.3
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
ADA Assessment and Survey 2014 152
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Men's Restroom 2569
Barrier #: 43M
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet ‐ Rear Grab Bar
Barrier Description:
Rear grab bar not centered 12" from wall and 24" on the other side of WC
Rec. Solution: Replace grab bars with reinforcement
Findings:
14‐1/2" on center
Quantity: JOB
Notes:
Barrier Severity: 3 Hindrance Cost Est $450.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.5.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Men's Restroom 2569
Barrier #: 43N
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Centerline
Barrier Description:
Water closet centerline not between 16" and 18" O. C.
Rec. Solution: Relocate water closet
Findings:
18‐1/2" on center
Quantity: JOB
Notes:
Barrier Severity: 3 Hindrance Cost Est $850.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
ADA Assessment and Survey 2014 153
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Men's Restroom 2569
Barrier #: 43O
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Seat Cover Dispenser
Barrier Description:
Seat cover dispenser not located on an accessible route. Blocked by water closet
Rec. Solution: Replace or remount dispenser on an accessible route with clear floor space
Findings:
Access to dispenser blocked by water closet
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $125.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Men's Restroom 2569
Barrier #: 43P
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Paper Dispenser
Barrier Description:
Toilet tissue dispenser not within 7" to 9" from front edge of toilet
Rec. Solution: Reposition or replace toilet paper dispenser
Findings:
13" from front edge of toilet
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $225.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.7
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
ADA Assessment and Survey 2014 154
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Men's Restroom 2569
Barrier #: 43Q
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Women's Restroom 2566
Barrier #: 44A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
62" high
Quantity: EACH
Notes: Also, Braille not 3/8" and max. 1/2" directly below the tactile characters, Braille dots on sign not domed or rounded
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
ADA Assessment and Survey 2014 155
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Women's Restroom 2566
Barrier #: 44B
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Interior
Barrier Description:
Door opening force exceeds 5 lbf
Rec. Solution: Provide automatic door opening device
Findings:
18 lbf
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $5,000.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.9
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Women's Restroom 2566
Barrier #: 44C
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Sweep Period
Barrier Description:
Door closer lacks min. 5 second sweep period
Rec. Solution: Provide automatic door opening device
Findings:
2 second sweep
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.8.1
As‐built : 0
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
ADA Assessment and Survey 2014 156
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Women's Restroom 2566
Barrier #: 44D
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Dispensers ‐ Protruding Object
Barrier Description:
Protruding dispenser creates protruding hazard in path of travel
Rec. Solution: Remove dispensers or provide detectable warning for the visually impaired
Findings:
Feminine product dispensers protrude 6" at 42" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $1,100.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307.2
As‐built : 2
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Women's Restroom 2566
Barrier #: 44E
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Dispensers ‐ Sanitary Products
Barrier Description:
Feminine product dispenser not usable with a closed fist
Rec. Solution: Replace dispensers
Findings:
Dispensers not fist operable
Quantity: EACH
Notes: 1 of 2 feminine product dispensers
Barrier Severity: 1 Necessary Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 603.3
As‐built : 0
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
ADA Assessment and Survey 2014 157
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Women's Restroom 2566
Barrier #: 44F
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Dispensers ‐ Sanitary Products
Barrier Description:
Feminine product dispenser does not operate at 5 lbf or less
Rec. Solution: Replace dispensers
Findings:
Exceed 5 lbf
Quantity: EACH
Notes: 2 of 2 feminine product dispensers
Barrier Severity: 1 Necessary Cost Est $650.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 603.3
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Women's Restroom 2566
Barrier #: 44G
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Protruding Object ‐ Wall‐mounted
Barrier Description:
Object protrudes more than 4" into circulation path
Rec. Solution: Remove object or provide detectable warning for the visually impaired
Findings:
Dryer protrudes 6" at 42" high
Quantity: JOB
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307.2
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
ADA Assessment and Survey 2014 158
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Women's Restroom 2566
Barrier #: 44H
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Lavatory ‐ Rim Height
Barrier Description:
Lavatory rim or counter edge is higher than 34" AFF
Rec. Solution: Provide min. 1 accessible lavatory
Findings:
34‐7/8" high AFF
Quantity: JOB
Notes:
Barrier Severity: 1 Necessary Cost Est $450.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 606.3
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Women's Restroom 2566
Barrier #: 44I
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Electrical Outlets ‐ Forward Reach Obstructed (10"‐25")
Barrier Description:
Outlet located over an 10" to 25" obstruction max. 34" high located above 44"
Rec. Solution: Relocate control or mechanism to max. 44" high
Findings:
44" high and 26" deep over an obstruction 34" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 308.2.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
ADA Assessment and Survey 2014 159
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Women's Restroom 2566
Barrier #: 44J
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Stall ‐ Door Hardware
Barrier Description:
Outside of compartment door lacks a loop or U‐pull below latch
Rec. Solution: Provide hardware
Findings:
No U‐pull provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $75.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.8.1.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Women's Restroom 2566
Barrier #: 44K
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Stall ‐ Door Hardware
Barrier Description:
Inside of compartment door lacks a loop or U‐pull below latch
Rec. Solution: Provide hardware
Findings:
No U‐pull provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $75.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.8.1.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
ADA Assessment and Survey 2014 160
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Women's Restroom 2566
Barrier #: 44L
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Seat Cover Dispenser
Barrier Description:
Seat cover dispenser not located on an accessible route. Blocked by water closet
Rec. Solution: Replace or remount dispenser on an accessible route with clear floor space
Findings:
Access to dispenser blocked by water closet
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $125.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Women's Restroom 2566
Barrier #: 44M
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Paper Dispenser
Barrier Description:
Toilet tissue dispenser not within 7" to 9" from front edge of toilet
Rec. Solution: Reposition or replace toilet paper dispenser
Findings:
17" from front edge of toilet
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $225.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.7
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
ADA Assessment and Survey 2014 161
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Women's Restroom 2566
Barrier #: 44N
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Franklin A McEdward Reading Area
Barrier #: 45A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Permanent Room/Space ‐ Tactile Characters
Barrier Description:
No tactile characters at sign identifying permanent rooms and spaces with visual signs
Rec. Solution: Provide accessible sign
Findings:
No tactile signage provided at door within public route
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 216.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
ADA Assessment and Survey 2014 162
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Franklin A McEdward Reading Area
Barrier #: 45B
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61" high at rooms 2088, 2615 and 2064
Quantity: EACH
Notes: Also, braille not 3/8" and max. 1/2" directly below the tactile characters, braille on signs not located directly below tactile characters and braille dots on signs not domed or rounded
Barrier Severity: 1 Necessary Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 3
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Franklin A McEdward Reading Area
Barrier #: 45C
X Coordinate: N/A
Barrier Area: Library Facilities
Barrier Type: Lockers ‐ Ratio
Barrier Description:
No accessible locker provided
Rec. Solution: Provide min. 1 accessible locker or 5% overall
Findings:
8 lockers and none are accessible
Quantity: EACH
Notes: 36 accessible study carrels provided
Barrier Severity: 2 Recommended Cost Est $450.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 225.2.1
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
ADA Assessment and Survey 2014 163
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Franklin A McEdward Reading Area
Barrier #: 45D
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 77‐1/2" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ East Corridor H2000
Barrier #: 46A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground or floor
Rec. Solution: Relocate signs or replace
Findings:
61" high at room 2084
Quantity: EACH
Notes: Also, braille not 3/8" and max. 1/2" directly below the tactile characters, braille on signs not located directly below tactile characters and braille dots on signs not domed or rounded
Barrier Severity: 1 Necessary Cost Est $500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 2
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
ADA Assessment and Survey 2014 164
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ East Corridor H2000
Barrier #: 46B
X Coordinate: N/A
Barrier Area: Corridors
Barrier Type: Lockers ‐ Ratio
Barrier Description:
No accessible locker provided
Rec. Solution: Provide min. 1 accessible locker or 5% overall
Findings:
8 lockers and none are accessible
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $450.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 803
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ East Corridor H2000
Barrier #: 46C
X Coordinate: N/A
Barrier Area: Corridors
Barrier Type: Lockers ‐ Control
Barrier Description:
Locker mechanism not operable with fist or involves turning and grasping
Rec. Solution: Provide min. 1 accessible lockers
Findings:
Lock mechanisms not accessible
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 803.5
As‐built : 0
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
ADA Assessment and Survey 2014 165
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Newspaper Viewing Room 2071
Barrier #: 47A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Permanent Room/Space ‐ Tactile Characters
Barrier Description:
No tactile characters at sign identifying permanent rooms and spaces with visual signs
Rec. Solution: Provide accessible sign
Findings:
No tactile signage provided at door within public route
Quantity: EACH
Notes: 4 accessible desks provided
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 216.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Newspaper Viewing Room 2071
Barrier #: 47B
X Coordinate: N/A
Barrier Area: Library Facilities
Barrier Type: Self‐Service Shelving
Barrier Description:
Self‐service shelves not accessible (max. 48" high)
Rec. Solution: Provide assistance
Findings:
Newspaper stack higher than 48" high
Quantity: JOB
Notes:
Barrier Severity: 3 Hindrance Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 225.2.2
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
ADA Assessment and Survey 2014 166
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Thomas & Beverly Hartung Gallery 2085
Barrier #: 48A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Permanent Room/Space ‐ Tactile Characters
Barrier Description:
No tactile characters at sign identifying permanent rooms and spaces with visual signs
Rec. Solution: Provide accessible sign
Findings:
No tactile signage provided at door within public route
Quantity: EACH
Notes: 6 accessible tables provided
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 216.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Thomas & Beverly Hartung Gallery 2085
Barrier #: 48B
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Visual Information Provided (Exhibitions)
Barrier Description:
Visual sign providing information for program, service or activity not accessible
Rec. Solution: Provide information in alternate format to provide access to people with vision impairments
Findings:
Accessible sign not provided
Quantity: JOB
Notes: Art exhibits have no information for visually impaired
Barrier Severity: 1 Necessary Cost Est $5,000.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
ADA Title II Technical Assistance Manual 3.2000 Denial of participation
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
ADA Assessment and Survey 2014 167
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Thomas & Beverly Hartung Gallery 2085
Barrier #: 48C
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobes
Findings:
Strobes mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $1,100.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 2
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Thomas & Beverly Hartung Gallery 2085
Barrier #: 48D
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe ‐ Spacing at 50'
Barrier Description:
Common corridors lack strobes every 50’
Rec. Solution: Provide additional strobe devices
Findings:
Devices not provided every 50'
Quantity: EACH
Notes: Strobes mounted 18' apart
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
ADA Assessment and Survey 2014 168
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Rotunda Area 2099
Barrier #: 49A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Permanent Room/Space ‐ Tactile Characters
Barrier Description:
No tactile characters at sign identifying permanent rooms and spaces with visual signs
Rec. Solution: Provide accessible sign
Findings:
No tactile signage provided at door within public route
Quantity: EACH
Notes: 14 accessible tables provided
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 216.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Rotunda Area 2099
Barrier #: 49B
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
ADA Assessment and Survey 2014 169
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Don Burlingham Reading Alcove 2091
Barrier #: 50A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Permanent Room/Space ‐ Tactile Characters
Barrier Description:
No tactile characters at sign identifying permanent rooms and spaces with visual signs
Rec. Solution: Provide accessible sign
Findings:
No tactile signage provided at door within public route
Quantity: EACH
Notes: 4 accessible tables provided
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 216.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Don Burlingham Reading Alcove 2091
Barrier #: 50B
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
ADA Assessment and Survey 2014 170
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Don Burlingham Reading Alcove 2081
Barrier #: 51A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Permanent Room/Space ‐ Tactile Characters
Barrier Description:
No tactile characters at sign identifying permanent rooms and spaces with visual signs
Rec. Solution: Provide accessible sign
Findings:
No tactile signage provided at door within public route
Quantity: EACH
Notes: 1 accessible desk provided
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 216.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Don Burlingham Reading Alcove 2081
Barrier #: 51B
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Horn/Strobe ‐ Common Use Area
Barrier Description:
No horn/strobes in common use areas
Rec. Solution: Provide strobe in common use area
Findings:
No device provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $5,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702.1
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
ADA Assessment and Survey 2014 171
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Autzen Classroom 2082
Barrier #: 52A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61" high
Quantity: EACH
Notes: Also, Braille not 3/8" and max. 1/2" directly below the tactile characters and Braille dots on signs not domed or rounded
Barrier Severity: 1 Necessary Cost Est $500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 2
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Autzen Classroom 2082
Barrier #: 52B
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Interior
Barrier Description:
Door opening force exceeds 5 lbf
Rec. Solution: Provide automatic door opening device at one door and ISA sign at other door
Findings:
11 lbf at both entry doors
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $5,000.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.9
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
ADA Assessment and Survey 2014 172
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Autzen Classroom 2082
Barrier #: 52C
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Sweep Period
Barrier Description:
Door closer lacks min. 5 second sweep period
Rec. Solution: Provide automatic door opening device at one door and ISA sign at other door
Findings:
3 second sweep
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.8.1
As‐built : 0
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Autzen Classroom 2082
Barrier #: 52D
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Tactile Exit Signs ‐ Passage
Barrier Description:
Exit thru an exit enclosure/exit passageway lacks tactile exit sign
Rec. Solution: Provide signs stating “EXIT ROUTE” at exit side of door
Findings:
Passageway to exterior exit with low level illuminated sign lacks tactile exit sign
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 2
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 4 of 8
ADA Assessment and Survey 2014 173
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Autzen Classroom 2082
Barrier #: 52E
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61‐1/2" high at storage room 2086
Quantity: EACH
Notes: Also, Braille not 3/8" and max. 1/2" directly below the tactile characters and Braille dots on sign not domed or rounded
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Autzen Classroom 2082
Barrier #: 52F
X Coordinate: N/A
Barrier Area: Classrooms
Barrier Type: Workstation ‐ Ratio
Barrier Description:
At least 1 workstation or 5% of all workstations are not accessible
Rec. Solution: Provide at least 1 accessible workstations
Findings:
24 Mac workstations and none are accessible
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $1,750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 902
As‐built : 2
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
ADA Assessment and Survey 2014 174
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Autzen Classroom 2082
Barrier #: 52G
X Coordinate: N/A
Barrier Area: Classrooms
Barrier Type: Workstation ‐ Knee Clearance
Barrier Description:
Knee clearance of at least 27" high, 30" wide and 8" deep not provided
Rec. Solution: Provide min. 1 accessible workstation or 5% overall
Findings:
25‐1/2" high knee clearance
Quantity: EACH
Notes: Mac workstations
Barrier Severity: 1 Necessary Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 902
As‐built : 0
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Autzen Classroom 2082
Barrier #: 52H
X Coordinate: N/A
Barrier Area: Counters and Tables
Barrier Type: Table ‐ Knee Clearance
Barrier Description:
Knee clearance not min. 27" high, 19" deep or 30" wide
Rec. Solution: Provide min. 1 accessible table
Findings:
25‐1/2" high knee clearance at 5 group tables
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $450.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
ADA Assessment and Survey 2014 175
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Autzen Classroom 2082
Barrier #: 52I
X Coordinate: N/A
Barrier Area: Classrooms
Barrier Type: Counter ‐ Surface
Barrier Description:
Counter surface height exceeds 34" high
Rec. Solution: Replace or provide alternative accessible and integrated counter
Findings:
Work counter used for handouts 36" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $875.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 902
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Autzen Classroom 2082
Barrier #: 52J
X Coordinate: N/A
Barrier Area: Classrooms
Barrier Type: Workstation ‐ Surface Max. 34"
Barrier Description:
Workstation surface height exceeds 34" high
Rec. Solution: Provide min. 1 accessible workstation or 5% overall
Findings:
Overhead projector workstation 36" high workstation surface
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $875.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 902
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
ADA Assessment and Survey 2014 176
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ East Exit Stairway S2090
Barrier #: 53A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Tactile Exit Signs ‐ Stairway
Barrier Description:
Door leading directly into an exit stairway lacks tactile exit sign
Rec. Solution: Provide sign stating “EXIT STAIR DOWN (or UP)” at latch side of door
Findings:
Door to exit stair with low level illuminated sign lacks tactile exit sign
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 4 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ East Exit Stairway S2090
Barrier #: 53B
X Coordinate: N/A
Barrier Area: Stairways
Barrier Type: Sign ‐ Enclosed Exit Stairway (Ch 10)
Barrier Description:
Tactile stairway signage incorrectly indicates roof access, info for emergency personnel
Rec. Solution: Move existing sign and provide separate tactile stairway level sign at latch side of door
Findings:
Sign provided is misleading to the visually impaired
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
ICC A117.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
ADA Assessment and Survey 2014 177
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ East Exit Stairway S2090
Barrier #: 53C
X Coordinate: N/A
Barrier Area: Clear Floor Space
Barrier Type: Protruding Object
Barrier Description:
Protruding object in circulation path protrudes more than 4" between 27" and 80" high
Rec. Solution: Remove object or provide detectable warning for the visually impaired
Findings:
Fire riser hose bib protrudes 14" at 45" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ East Exit Stairway S2090
Barrier #: 53D
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Horn/Strobe ‐ Common Use Area
Barrier Description:
No horn/strobes in common use areas
Rec. Solution: Provide strobe in common use area
Findings:
No device provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $5,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702.1
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 4 of 8
ADA Assessment and Survey 2014 178
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ West Exit Stairway S3090
Barrier #: 54A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Tactile Exit Signs ‐ Stairway
Barrier Description:
Door leading directly into an exit stairway lacks tactile exit sign
Rec. Solution: Provide sign stating “EXIT STAIR DOWN (or UP)” at latch side of door
Findings:
Door to exit stair with low level illuminated sign lacks tactile exit sign
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ West Exit Stairway S3090
Barrier #: 54B
X Coordinate: N/A
Barrier Area: Stairways
Barrier Type: Sign ‐ Enclosed Exit Stairway (Ch 10)
Barrier Description:
Tactile stairway signage incorrectly indicates roof access, info for emergency personnel
Rec. Solution: Move existing sign and provide separate tactile stairway level sign at latch side of door
Findings:
Sign provided is misleading to the visually impaired
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
ICC A117.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 179
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ West Exit Stairway S3090
Barrier #: 54C
X Coordinate: N/A
Barrier Area: Clear Floor Space
Barrier Type: Protruding Object
Barrier Description:
Protruding object in circulation path protrudes more than 4" between 27" and 80" high
Rec. Solution: Remove object or provide detectable warning for the visually impaired
Findings:
Fire riser hose bib protrudes 16‐1/2" at 46" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ West Exit Stairway S3090
Barrier #: 54D
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Horn/Strobe ‐ Common Use Area
Barrier Description:
No horn/strobes in common use areas
Rec. Solution: Provide strobe in common use area
Findings:
No device provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $5,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702.1
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 180
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Central Hall H3000
Barrier #: 55A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Lobby Info Sign
Barrier Description:
No lobby informational sign with location of accessible elements
Rec. Solution: Provide lobby informational sign
Findings:
Accessible sign not provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Central Hall H3000
Barrier #: 55B
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Visual Information Provided (Exhibitions)
Barrier Description:
Visual sign providing information for program, service or activity not accessible
Rec. Solution: Provide information in alternate format to provide access to people with vision impairments
Findings:
Accessible sign not provided
Quantity: JOB
Notes: Artwork exhibited lacks description for the visually impaired
Barrier Severity: 1 Necessary Cost Est $5,000.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
ADA Title II Technical Assistance Manual 3.2000 Denial of participation
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 181
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Central Hall H3000
Barrier #: 55C
X Coordinate: N/A
Barrier Area: Elevators
Barrier Type: Hall Call Buttons ‐ 42" High
Barrier Description:
The centerline of the hall call buttons not max. 42" above the floor
Rec. Solution: Replace hall call buttons
Findings:
42‐1/4" high on center
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $3,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 407.2.1
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Central Hall H3000
Barrier #: 55D
X Coordinate: N/A
Barrier Area: Corridors
Barrier Type: Lockers ‐ Ratio
Barrier Description:
No accessible locker provided
Rec. Solution: Provide at least 4 accessible lockers
Findings:
64 lockers and none are accessible
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $1,350.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 803
As‐built : 3
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 182
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Central Hall H3000
Barrier #: 55E
X Coordinate: N/A
Barrier Area: Corridors
Barrier Type: Lockers ‐ Control
Barrier Description:
Locker mechanism not operable with fist or involve turning and grasping
Rec. Solution: Provide at least 4 accessible lockers
Findings:
Lock mechanisms not accessible
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 803.5
As‐built : 0
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Central Hall H3000
Barrier #: 55F
X Coordinate: N/A
Barrier Area: Corridors
Barrier Type: Strobe Height ‐ 80" on Wall
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobes
Findings:
Strobes mounted 77‐1/2" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $2,200.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 4
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 183
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Government Documents Area 3031
Barrier #: 56A
X Coordinate: N/A
Barrier Area: Clear Floor Space
Barrier Type: Passageway ‐ Min. 36"
Barrier Description:
Circulation route not min. 36" wide between elements
Rec. Solution: Provide assistance with movable stacks to ensure access
Findings:
Less than 36" wide circulation route between double sided stacks in multiple locations
Quantity: LF
Notes: Accessible study carrels provided in this area
Barrier Severity: 1 Necessary Cost Est $125.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 403.5.1
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Government Documents Area 3031
Barrier #: 56B
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobes
Findings:
Strobes mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $2,200.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 4
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 184
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Library Catalogue Area 3062
Barrier #: 57A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Permanent Room/Space ‐ Tactile Characters
Barrier Description:
No tactile characters at sign identifying permanent rooms and spaces with visual signs
Rec. Solution: Provide accessible sign
Findings:
Overhead visual sign info not provided in tactile signage at doorway within public route
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 216.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Library Catalogue Area 3062
Barrier #: 57B
X Coordinate: N/A
Barrier Area: Counters and Tables
Barrier Type: Counter ‐ Surface Height
Barrier Description:
No section at least 3 feet long between 28" and 34" provided at existing counter
Rec. Solution: Provide min. 1 accessible scanner
Findings:
Scanner counter 36" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $875.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 902.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 185
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Library Catalogue Area 3062
Barrier #: 57C
X Coordinate: N/A
Barrier Area: Counters and Tables
Barrier Type: Counter ‐ Knee Clearance
Barrier Description:
Knee clearance not min. 27" high, 19" deep or 30" wide
Rec. Solution: Provide min. 3 ft segment of accessible counter. Flip‐up counters, adjacent tables and similar d
Findings:
No knee clearance at fixed work counter
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $875.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Library Catalogue Area 3062
Barrier #: 57D
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Electrical Outlets ‐ Side Reach Obstructed (10"‐24")
Barrier Description:
Outlet located over an 10" to 24" obstruction max. 34" high located above 46"
Rec. Solution: Relocate control or mechanism to max. 46" high
Findings:
Power strip below desk surface hanging along back wall at accessible computer carrel
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 186
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Library Catalogue Area 3062
Barrier #: 57E
X Coordinate: N/A
Barrier Area: Library Facilities
Barrier Type: Actuator/Control ‐ Side Reach Obstructed (10"‐24")
Barrier Description:
Control or mechanism over an 10" to 24" obstruction max. 34" high located above 46"
Rec. Solution: Relocate control or mechanism to max. 46" high
Findings:
Microfiche control displays 50" high and 16" deep over an obstruction 36" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Study Area
Barrier #: 58A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61‐1/2" high
Quantity: EACH
Notes: Also, Braille not 3/8" and max. 1/2" directly below the tactile characters and Braille dots on signs not domed or rounded. 4 accessible tables provided
Barrier Severity: 1 Necessary Cost Est $500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 2
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 187
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Study Area
Barrier #: 58B
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Visual Information Provided (Exhibitions)
Barrier Description:
Visual sign providing information for program, service or activity not accessible
Rec. Solution: Provide information in alternate format to provide access to people with vision impairments
Findings:
Accessible sign not provided
Quantity: JOB
Notes: Artwork exhibited lacks description for the visually impaired
Barrier Severity: 1 Necessary Cost Est $5,000.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
ADA Title II Technical Assistance Manual 3.2000 Denial of participation
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Williamette East Meeting Room 3622
Barrier #: 59A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61‐1/2" high
Quantity: EACH
Notes: Also, Braille not 3/8" and max. 1/2" directly below the tactile characters and Braille dots on sign not domed or rounded
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 188
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Williamette East Meeting Room 3622
Barrier #: 59B
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Electrical Switches ‐ Height
Barrier Description:
Light switch control box top edge not at max. 48" high
Rec. Solution: Relocate switch box top edge to max. 48" high
Findings:
50" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 308.2
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Williamette East Meeting Room 3622
Barrier #: 59C
X Coordinate: N/A
Barrier Area: Classrooms
Barrier Type: Podium ‐ Surface Height
Barrier Description:
Surface height exceeds 34" high
Rec. Solution: Provide min. 1 accessible podium
Findings:
41" and 42‐1/2" surface height
Quantity: SF
Notes: 2 podiums and neither is accessible
Barrier Severity: 4 Low Severity Cost Est $1,275.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 504.2
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 189
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Williamette East Meeting Room 3622
Barrier #: 59D
X Coordinate: N/A
Barrier Area: Assembly Areas
Barrier Type: Shared Assistive Listening System
Barrier Description:
No shared assistive listening system for room with min. 10 seats
Rec. Solution: Provide shared ALS system
Findings:
No system provided
Quantity: EACH
Notes: 2 podiums and neither is accessible
Barrier Severity: 2 Recommended Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Williamette East Meeting Room 3622
Barrier #: 59E
X Coordinate: N/A
Barrier Area: Classrooms
Barrier Type: Projector Screen Pull
Barrier Description:
Screen pull not at max. 48" high for side reach
Rec. Solution: Relocate to max. 48" high or provide extension
Findings:
Projector screen pull over 48" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $75.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 190
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Williamette East Meeting Room 3622
Barrier #: 59F
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Williamette West Meeting Room 3622
Barrier #: 60A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61‐1/2" high
Quantity: EACH
Notes: Also, Braille not 3/8" and max. 1/2" directly below the tactile characters and Braille dots on sign not domed or rounded
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 191
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Williamette West Meeting Room 3622
Barrier #: 60B
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Electrical Switches ‐ Height
Barrier Description:
Light switch control box top edge not at max. 48" high
Rec. Solution: Relocate switch box top edge to max. 48" high
Findings:
50" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 308.2
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Williamette West Meeting Room 3622
Barrier #: 60C
X Coordinate: N/A
Barrier Area: Classrooms
Barrier Type: Podium ‐ Surface Height
Barrier Description:
Surface height exceeds 34" high
Rec. Solution: Provide min. 1 accessible podium
Findings:
41" and 42‐1/2" surface height
Quantity: SF
Notes: 2 podiums and neither is accessible
Barrier Severity: 4 Low Severity Cost Est $1,275.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 504.2
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 192
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Williamette West Meeting Room 3622
Barrier #: 60D
X Coordinate: N/A
Barrier Area: Assembly Areas
Barrier Type: Shared Assistive Listening System
Barrier Description:
No shared assistive listening system for room with min. 10 seats
Rec. Solution: Provide shared ALS system
Findings:
No system provided
Quantity: EACH
Notes: 2 podiums and neither is accessible
Barrier Severity: 2 Recommended Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Williamette West Meeting Room 3622
Barrier #: 60E
X Coordinate: N/A
Barrier Area: Classrooms
Barrier Type: Projector Screen Pull
Barrier Description:
Screen pull not at max. 48" high for side reach
Rec. Solution: Relocate to max. 48" high or provide extension
Findings:
Projector screen pull over 48" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $75.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 193
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Williamette West Meeting Room 3622
Barrier #: 60F
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Corridor H3600
Barrier #: 61A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61‐1/2" high at rooms 3169, 3615 and 3730.
Quantity: EACH
Notes: Also, Braille not 3/8" and max. 1/2" directly below the tactile characters abd Braille dots on signs not domed or rounded
Barrier Severity: 1 Necessary Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 3
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 194
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Corridor H3600
Barrier #: 61B
X Coordinate: N/A
Barrier Area: Corridors
Barrier Type: Strobe Height ‐ 80" on Wall
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Kitchenette/Break Room 3880
Barrier #: 62A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61‐1/2" high
Quantity: EACH
Notes: Also, Braille not 3/8" and max. 1/2" directly below the tactile characters abd Braille dots on signs not domed or rounded
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 195
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Kitchenette/Break Room 3880
Barrier #: 62B
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Electrical Switches ‐ Height
Barrier Description:
Light switch control box top edge not at max. 48" high
Rec. Solution: Relocate switch box top edge to max. 48" high
Findings:
50" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 308.2
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Kitchenette/Break Room 3880
Barrier #: 62C
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: First Aid Kit ‐ High Reach Range
Barrier Description:
Opening mechanism on first aid kit not at max. 48" high for side reach
Rec. Solution: Relocate control or mechanism to max. 48" high
Findings:
52‐1/2" high but contents at 65" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $275.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 196
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Kitchenette/Break Room 3880
Barrier #: 62D
X Coordinate: N/A
Barrier Area: Kitchens
Barrier Type: Cooktop
Barrier Description:
The location of controls involves reaching across burners
Rec. Solution: Replace cooktop/range
Findings:
Range controls force users to reach over hotplates
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $275.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 804.4.6.4
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Kitchenette/Break Room 3880
Barrier #: 62E
X Coordinate: N/A
Barrier Area: Kitchens
Barrier Type: Counter Surfaces
Barrier Description:
An accessible segment of counter not provided at both sink and stove/oven
Rec. Solution: Provide accessible sections of counter in both locations
Findings:
30" long accessible section of counter at stove. No accessible counter at sink
Quantity: JOB
Notes:
Barrier Severity: 2 Recommended Cost Est $1,680.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS Figure 804.2.2
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 197
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Kitchenette/Break Room 3880
Barrier #: 62F
X Coordinate: N/A
Barrier Area: Classrooms
Barrier Type: Sink ‐ Knee Clearance
Barrier Description:
Knee clearance of at least 27" high, 19" deep and 30" wide not provided
Rec. Solution: Replace cabinet and remount sink
Findings:
4‐1/2" deep knee clearance
Quantity: LF
Notes:
Barrier Severity: 1 Necessary Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 606.2 & 306
As‐built : 0
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Kitchenette/Break Room 3880
Barrier #: 62G
X Coordinate: N/A
Barrier Area: Counters and Tables
Barrier Type: Counter ‐ Surface Height
Barrier Description:
No section at least 3 feet long between 28" and 34" provided at existing counter
Rec. Solution: Provide min. 3 ft long section of counter at max. 34" high
Findings:
36" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 902.3
As‐built : 0
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 198
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Kitchenette/Break Room 3880
Barrier #: 62H
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Electrical Outlets ‐ Forward Reach Obstructed (10"‐25")
Barrier Description:
Outlet located over an 10" to 25" obstruction max. 34" high located above 44"
Rec. Solution: Relocate control or mechanism to max. 44" high
Findings:
42" high and 25" deep over an obstruction 36" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 308.2.2
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Kitchenette/Break Room 3880
Barrier #: 62I
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Actuator/Control ‐ Forward Reach Obstructed (10"‐25")
Barrier Description:
Control or mechanism over an 10" to 25" obstruction max. 34" high located above 44"
Rec. Solution: Relocate control or mechanism to max. 44" high
Findings:
Soap and paper towel dispensers 48" high and 22" deep over an obstruction 36" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $1,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 308.2
As‐built : 2
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 199
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Kitchenette/Break Room 3880
Barrier #: 62J
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Break Room Dining Area 3779
Barrier #: 63A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Tactile Exit Signs ‐ Passage
Barrier Description:
Exit thru an exit enclosure/exit passageway lacks tactile exit sign
Rec. Solution: Provide sign stating “EXIT ROUTE” at exit side of door
Findings:
Passageway to exterior exit with low level illuminated sign lacks tactile exit sign
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 200
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Break Room Dining Area 3779
Barrier #: 63B
X Coordinate: N/A
Barrier Area: Library Facilities
Barrier Type: Table ‐ Pedestal Base
Barrier Description:
Knee clearance not min. 27" high, 19" deep or 30" wide
Rec. Solution: Provide min. 1 accessible table. Avoid pedestal base tables
Findings:
9 pedestal tables provided and none are accessible
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 306.2.2 and 306.2.3
As‐built : 0
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Break Room Dining Area 3779
Barrier #: 63C
X Coordinate: N/A
Barrier Area: Counters and Tables
Barrier Type: Desk ‐ Knee Clearance
Barrier Description:
Knee clearance not min. 27" high, 19" deep or 30" wide
Rec. Solution: Provide min. one accessible PC workstation
Findings:
Computer station located on a pedestal table
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $875.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 902.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 201
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Break Room Dining Area 3779
Barrier #: 63D
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Exit Stairway S2790
Barrier #: 64A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Tactile Exit Signs ‐ Stairway
Barrier Description:
Door leading directly into an exit stairway lacks tactile exit sign
Rec. Solution: Provide sign stating “EXIT STAIR DOWN (or UP)” at latch side of door
Findings:
Door to exit stair with low level illuminated sign lacks tactile exit sign. Existing sign states "STAIR"
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 202
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Exit Stairway S2790
Barrier #: 64B
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Interior Adjustment
Barrier Description:
Door opening force exceeds 5 lbf
Rec. Solution: Replace or adjust existing closers. Door does not lead to an accessible route
Findings:
17 lbf at entry doors to stairway and 19 lbf at door to exterior
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $1,350.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.9
As‐built : 3
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Exit Stairway S2790
Barrier #: 64C
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Interior Sweep Period
Barrier Description:
Door closer lacks min. 5 second sweep period or does not stop 5" from door frame
Rec. Solution: Replace or adjust existing closers. Door does not lead to an accessible route
Findings:
3 second sweep at all 3 doors within stairway
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.8.1
As‐built : 3
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 203
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 2 ‐ Exit Stairway S2790
Barrier #: 64D
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Horn/Strobe ‐ Common Use Area
Barrier Description:
No horn/strobes in common use areas
Rec. Solution: Provide strobe in common use area
Findings:
No device provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $5,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702.1
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Elevator/Restroom Corridor H3500
Barrier #: 65A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Permanent Room/Space ‐ Tactile Characters
Barrier Description:
No tactile characters at sign identifying permanent rooms and spaces with visual signs
Rec. Solution: Provide accessible signs
Findings:
No tactile signage provided at door within public route
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 216.2
As‐built : 2
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 204
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Elevator/Restroom Corridor H3500
Barrier #: 65B
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61" high at room 3567
Quantity: EACH
Notes: Also, Braille not 3/8" and max. 1/2" directly below the tactile characters abd Braille dots on signs not domed or rounded
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Elevator/Restroom Corridor H3500
Barrier #: 65C
X Coordinate: N/A
Barrier Area: Drinking Fountains
Barrier Type: Alcove ‐ New Construction
Barrier Description:
Fountain with a leading edge between 27" and 80" high protrudes more than 4" into the circulation path.
Rec. Solution: Demolish and construct new alcove as detectable warning
Findings:
Hi‐Low drinking fountain not completely inside alcove
Quantity: SF
Notes:
Barrier Severity: 1 Necessary Cost Est $2,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307.2
As‐built : 10
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 205
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Elevator/Restroom Corridor H3500
Barrier #: 65D
X Coordinate: N/A
Barrier Area: Drinking Fountains
Barrier Type: Operation ‐ Replacement
Barrier Description:
Operating mechanism involves more than 5 lbf to operate
Rec. Solution: Replace drinking fountain with accessible unit
Findings:
Needed more than 5 lbf where fountain is not adjustable
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 602.3
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Elevator/Restroom Corridor H3500
Barrier #: 65E
X Coordinate: N/A
Barrier Area: Drinking Fountains
Barrier Type: Knee Clearance
Barrier Description:
Knee clearance under fountain not min. 27" high
Rec. Solution: Remount drinking fountain with accessible knee clearance
Findings:
26‐7/8" high knee clearance
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 306.3
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 206
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Elevator/Restroom Corridor H3500
Barrier #: 65F
X Coordinate: N/A
Barrier Area: Drinking Fountains
Barrier Type: Bubbler water flow
Barrier Description:
Water flow from bubbler not min. 4" high
Rec. Solution: Adjust drinking fountain to provide min. 4" high water flow
Findings:
2" high water flow from bubbler
Quantity: JOB
Notes:
Barrier Severity: 2 Recommended Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 602.6
As‐built : 0
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Men's Restroom 3569
Barrier #: 66A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
62" high
Quantity: EACH
Notes: Also, Braille not 3/8" and max. 1/2" directly below the tactile characters abd Braille dots on signs not domed or rounded
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 207
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Men's Restroom 3569
Barrier #: 66B
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Interior
Barrier Description:
Door opening force exceeds 5 lbf
Rec. Solution: Provide automatic door opening device
Findings:
18 lbf
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $5,000.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.9
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Men's Restroom 3569
Barrier #: 66C
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Sweep Period
Barrier Description:
Door closer lacks min. 5 second sweep period
Rec. Solution: Provide automatic door opening device
Findings:
2 second sweep
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.8.1
As‐built : 0
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 208
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Men's Restroom 3569
Barrier #: 66D
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Dispensers ‐ Protruding Object
Barrier Description:
Protruding dispenser creates protruding hazard in path of travel
Rec. Solution: Remove dispenser or provide detectable warning for the visually impaired
Findings:
Paper towel dispenser protrudes 10" at 44" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307.2
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Men's Restroom 3569
Barrier #: 66E
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Lavatory ‐ Rim Height
Barrier Description:
Lavatory rim or counter edge is higher than 34" AFF
Rec. Solution: Provide min. 1 accessible lavatory
Findings:
34‐3/4" high AFF
Quantity: JOB
Notes:
Barrier Severity: 1 Necessary Cost Est $450.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 606.3
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 209
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Men's Restroom 3569
Barrier #: 66F
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Lavatory ‐ Knee Clearance
Barrier Description:
Lavatory bottom apron/edge not max 29" reducing to 27" at 8" back from edge
Rec. Solution: Remove cover at drainpipes
Findings:
7" deep knee clearance
Quantity: JOB
Notes:
Barrier Severity: 1 Necessary Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 606.2 & 306
As‐built : 0
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Men's Restroom 3569
Barrier #: 66G
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Electrical Outlets ‐ Side Reach Obstructed (10"‐24")
Barrier Description:
Outlet located over an 10" to 24" obstruction max. 34" high located above 46"
Rec. Solution: Relocate control or mechanism to max. 46" high
Findings:
44" high and 20" deep over an obstruction 34‐1/4" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 210
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Men's Restroom 3569
Barrier #: 66H
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Stall Door Closer
Barrier Description:
Stall door not equipped with an automatic closing device
Rec. Solution: Replace compartment hinge with adjustible mechanism
Findings:
Stall door not self‐closing
Quantity: JOB
Notes:
Barrier Severity: 2 Recommended Cost Est $1,650.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.8.1.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Men's Restroom 3569
Barrier #: 66I
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Stall ‐ Door Hardware
Barrier Description:
Outside of compartment door lacks a loop or U‐pull below latch
Rec. Solution: Provide hardware
Findings:
No U‐pull provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $75.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.8.1.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 211
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Men's Restroom 3569
Barrier #: 66J
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Stall ‐ Door Hardware
Barrier Description:
Inside of compartment door lacks a loop or U‐pull below latch
Rec. Solution: Provide hardware
Findings:
No U‐pull provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $75.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.8.1.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Men's Restroom 3569
Barrier #: 66K
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet ‐ Rear Grab Bar
Barrier Description:
Rear grab bar not centered 12" from wall and 24" on the other side of WC
Rec. Solution: Replace grab bars with reinforcement
Findings:
13" on center
Quantity: JOB
Notes:
Barrier Severity: 3 Hindrance Cost Est $450.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.5.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 212
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Men's Restroom 3569
Barrier #: 66L
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Centerline
Barrier Description:
Water closet centerline not between 16" and 18" O. C.
Rec. Solution: Relocate water closet
Findings:
18‐1/4" on center
Quantity: JOB
Notes:
Barrier Severity: 3 Hindrance Cost Est $850.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Men's Restroom 3569
Barrier #: 66M
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Paper Dispenser
Barrier Description:
Toilet tissue dispenser not within 7" to 9" from front edge of toilet
Rec. Solution: Reposition or replace toilet paper dispenser
Findings:
12" from front edge of toilet
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $225.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.7
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 213
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Men's Restroom 3569
Barrier #: 66N
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Family/Assisted Restroom 3565
Barrier #: 67A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61" high
Quantity: EACH
Notes: Also, Braille not 3/8" and max. 1/2" directly below the tactile characters abd Braille dots on signs not domed or rounded
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 214
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Family/Assisted Restroom 3565
Barrier #: 67B
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Automatic Doors ‐ Sign
Barrier Description:
ISA symbol at automatic door opening device not min. 4" x 4" in size
Rec. Solution: Recommended: Provide ISA symbol min. 4" x 4" in size
Findings:
Existing symbol 1‐3/4" high. Nor visible from a distance
Quantity: JOB
Notes:
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Family/Assisted Restroom 3565
Barrier #: 67C
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Automatic Doors ‐ BHMA Sign
Barrier Description:
No sign on door visible from both sides reading, "AUTOMATIC DOOR"
Rec. Solution: Provide new signs on both sides of door
Findings:
No BHMA sign on either side of door
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
ANSI/BHMA A156.10‐1999
As‐built : 2
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 215
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Family/Assisted Restroom 3565
Barrier #: 67D
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Dispensers ‐ Protruding Object
Barrier Description:
Protruding dispenser creates protruding hazard in path of travel
Rec. Solution: Remove dispensers or provide detectable warning for the visually impaired
Findings:
Feminine product dispensers protrude 6" at 42" high. Paper towel dispenser protrudes 10" at 42" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $1,100.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307.2
As‐built : 2
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Family/Assisted Restroom 3565
Barrier #: 67E
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Lavatory ‐ Rim Height
Barrier Description:
Lavatory rim or counter edge is higher than 34" AFF
Rec. Solution: Provide min. 1 accessible lavatory
Findings:
34‐1/4" high AFF
Quantity: JOB
Notes:
Barrier Severity: 1 Necessary Cost Est $450.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 606.3
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 216
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Family/Assisted Restroom 3565
Barrier #: 67F
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Lavatory ‐ Knee Clearance
Barrier Description:
Lavatory bottom apron/edge not max 29" reducing to 27" at 8" back from edge
Rec. Solution: Remove cover at drainpipes
Findings:
6" deep knee clearance
Quantity: JOB
Notes:
Barrier Severity: 1 Necessary Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 606.2 & 306
As‐built : 0
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Family/Assisted Restroom 3565
Barrier #: 67G
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Electrical Outlets ‐ Side Reach Obstructed (10"‐24")
Barrier Description:
Outlet located over an 10" to 24" obstruction max. 34" high located above 46"
Rec. Solution: Relocate control or mechanism to max. 46" high
Findings:
Outlets behind dispensers and cannot be used
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 217
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Family/Assisted Restroom 3565
Barrier #: 67H
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Centerline
Barrier Description:
Water closet centerline not between 16" and 18" O. C.
Rec. Solution: Relocate water closet
Findings:
18‐1/2" on center
Quantity: JOB
Notes:
Barrier Severity: 3 Hindrance Cost Est $850.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Family/Assisted Restroom 3565
Barrier #: 67I
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Paper Dispenser
Barrier Description:
Toilet tissue dispenser not within 7" to 9" from front edge of toilet
Rec. Solution: Reposition or replace toilet paper dispenser
Findings:
14" from front edge of toilet
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $225.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.7
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 218
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Family/Assisted Restroom 3565
Barrier #: 67J
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Seat Cover Dispenser
Barrier Description:
Seat cover dispenser not located on an accessible route. Blocked by water closet
Rec. Solution: Replace or remount dispenser on an accessible route with clear floor space
Findings:
Access to dispenser blocked by water closet
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $125.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Family/Assisted Restroom 3565
Barrier #: 67K
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 219
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Women's Restroom 3566
Barrier #: 68A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
62" high
Quantity: EACH
Notes: Also, Braille not 3/8" and max. 1/2" directly below the tactile characters abd Braille dots on signs not domed or rounded
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Women's Restroom 3566
Barrier #: 68B
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Interior
Barrier Description:
Door opening force exceeds 5 lbf
Rec. Solution: Provide automatic door opening device
Findings:
18 lbf
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $5,000.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.9
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 220
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Women's Restroom 3566
Barrier #: 68C
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Sweep Period
Barrier Description:
Door closer lacks min. 5 second sweep period
Rec. Solution: Provide automatic door opening device
Findings:
4 second sweep
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.8.1
As‐built : 0
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Women's Restroom 3566
Barrier #: 68D
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Dispensers ‐ Protruding Object
Barrier Description:
Protruding dispenser creates protruding hazard in path of travel
Rec. Solution: Remove dispensers or provide detectable warning for the visually impaired
Findings:
Feminine product dispensers protrude 6" at 42" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $1,100.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307.2
As‐built : 2
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 221
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Women's Restroom 3566
Barrier #: 68E
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Dispensers ‐ Sanitary Products
Barrier Description:
Feminine product dispenser does not operate at 5 lbf or less
Rec. Solution: Replace dispensers
Findings:
Exceed 5 lbf
Quantity: EACH
Notes: 2 of 2 feminine product dispensers
Barrier Severity: 1 Necessary Cost Est $650.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 603.3
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Women's Restroom 3566
Barrier #: 68F
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Lavatory ‐ Rim Height
Barrier Description:
Lavatory rim or counter edge is higher than 34" AFF
Rec. Solution: Provide min. 1 accessible lavatory
Findings:
34‐5/8" high AFF
Quantity: JOB
Notes:
Barrier Severity: 1 Necessary Cost Est $450.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 606.3
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 222
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Women's Restroom 3566
Barrier #: 68G
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Electrical Outlets ‐ Side Reach Obstructed (10"‐24")
Barrier Description:
Outlet located over an 10" to 24" obstruction max. 34" high located above 46"
Rec. Solution: Relocate control or mechanism to max. 46" high
Findings:
44" high and 22" deep over an obstruction 34" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Women's Restroom 3566
Barrier #: 68H
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Stall ‐ Door Hardware
Barrier Description:
Inside of compartment door lacks a loop or U‐pull below latch
Rec. Solution: Provide hardware
Findings:
No U‐pull provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $75.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.8.1.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 223
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Women's Restroom 3566
Barrier #: 68I
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet ‐ Rear Grab Bar
Barrier Description:
Rear grab bar not centered 12" from wall and 24" on the other side of WC
Rec. Solution: Replace grab bars with reinforcement
Findings:
13" on center
Quantity: JOB
Notes:
Barrier Severity: 3 Hindrance Cost Est $450.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.5.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Women's Restroom 3566
Barrier #: 68J
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Centerline
Barrier Description:
Water closet centerline not between 16" and 18" O. C.
Rec. Solution: Relocate water closet
Findings:
18‐1/2" on center
Quantity: JOB
Notes:
Barrier Severity: 3 Hindrance Cost Est $850.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 224
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Women's Restroom 3566
Barrier #: 68K
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Paper Dispenser
Barrier Description:
Toilet tissue dispenser not within 7" to 9" from front edge of toilet
Rec. Solution: Reposition or replace toilet paper dispenser
Findings:
14" from front edge of toilet
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $225.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.7
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Women's Restroom 3566
Barrier #: 68L
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Seat Cover Dispenser
Barrier Description:
Seat cover dispenser not located on an accessible route. Blocked by water closet
Rec. Solution: Replace or remount dispenser on an accessible route with clear floor space
Findings:
Access to dispenser blocked by water closet
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $125.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 225
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Women's Restroom 3566
Barrier #: 68M
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Day Care Center 3564
Barrier #: 69A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61" high
Quantity: EACH
Notes: Also, Braille not 3/8" and max. 1/2" directly below the tactile characters abd Braille dots on signs not domed or rounded
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 226
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Day Care Center 3564
Barrier #: 69B
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Front App/pull 18" SEC ‐ Relocate Door
Barrier Description:
Door/Gate at pull side with min. 60" lacks min. 18" strike edge clearance at pull side
Rec. Solution: Provide automatic door opening device or remove counter to provide min. 18" clearance
Findings:
7" strike edge clearance
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $2,250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS Figure 404.2.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Day Care Center 3564
Barrier #: 69C
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Electrical Switches ‐ Height
Barrier Description:
Light switch control box top edge not at max. 48" high
Rec. Solution: Relocate switch box top edge to max. 48" high
Findings:
50" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 308.2
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 227
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Day Care Center 3564
Barrier #: 69D
X Coordinate: N/A
Barrier Area: Counters and Tables
Barrier Type: Counter ‐ Surface Height
Barrier Description:
No section at least 3 feet long between 28" and 34" provided at existing counter
Rec. Solution: Provide min. 3 ft long section of counters at max. 34" high
Findings:
39‐3/4" ‐ 40" high at 2 counters
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $875.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 902.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Day Care Center 3564
Barrier #: 69E
X Coordinate: N/A
Barrier Area: Clear Floor Space
Barrier Type: Passageway ‐ Min. 36"
Barrier Description:
Circulation route not min. 36" wide between elements
Rec. Solution: Demolish existing and construct new passageway
Findings:
27‐1/2" wide circulation route between counters in path of travel to play area
Quantity: LF
Notes:
Barrier Severity: 1 Necessary Cost Est $2,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 403.5.1
As‐built : 20
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 228
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Day Care Center 3564
Barrier #: 69F
X Coordinate: N/A
Barrier Area: Counters and Tables
Barrier Type: Workstation ‐ Knee Clearance
Barrier Description:
Knee clearance of at least 27" high, 30" wide and 8" deep not provided
Rec. Solution: Provide min. 1 accessible workstation or 5% overall
Findings:
No knee clearance at computer workstation
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $875.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 902
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Day Care Center 3564
Barrier #: 69G
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 229
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Acquistions and Cataloging 3730 & 3755
Barrier #: 70A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61" high Braille/tactile signs at entry door and conference room 3755
Quantity: EACH
Notes: Also, Braille not 3/8" and max. 1/2" directly below the tactile characters and Braille on signs not located directly below tactile characters
Barrier Severity: 1 Necessary Cost Est $500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 2
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Acquistions and Cataloging 3730 & 3755
Barrier #: 70B
X Coordinate: N/A
Barrier Area: Clear Floor Space
Barrier Type: Protruding Object
Barrier Description:
Protruding object in circulation path protrudes more than 4" between 27" and 80" high
Rec. Solution: Remove object or provide detectable warning for the visually impaired
Findings:
AED overhead sign at doorway protrudes at 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 230
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Acquistions and Cataloging 3730 & 3755
Barrier #: 70C
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Interior
Barrier Description:
Door opening force exceeds 5 lbf
Rec. Solution: Provide automatic door opening device
Findings:
13 lbf at entry door leading to conference room 3755
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $5,000.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.9
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Acquistions and Cataloging 3730 & 3755
Barrier #: 70D
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Sweep Period
Barrier Description:
Door closer lacks min. 5 second sweep period
Rec. Solution: Provide automatic door opening device
Findings:
3 second sweep
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.8.1
As‐built : 0
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 231
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Acquistions and Cataloging 3730 & 3755
Barrier #: 70E
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Electrical Switches ‐ Height
Barrier Description:
Light switch control box top edge not at max. 48" high
Rec. Solution: Relocate switch box top edge to max. 48" high
Findings:
50" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 308.2
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Acquistions and Cataloging 3730 & 3755
Barrier #: 70F
X Coordinate: N/A
Barrier Area: Counters and Tables
Barrier Type: Table ‐ Knee Clearance
Barrier Description:
Knee clearance not min. 27" high, 19" deep or 30" wide
Rec. Solution: Provide min. 1 accessible table
Findings:
Conference table has 26‐1/2" high knee clearance
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $450.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 232
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Acquistions and Cataloging 3730 & 3755
Barrier #: 70G
X Coordinate: N/A
Barrier Area: Counters and Tables
Barrier Type: Table ‐ Knee Clearance
Barrier Description:
Knee clearance not min. 27" high, 19" deep or 30" wide
Rec. Solution: Provide min. 1 accessible table
Findings:
Smaller table 26‐1/2" high knee clearance
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $450.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Acquistions and Cataloging 3730 & 3755
Barrier #: 70H
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 233
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Microfilm Center 3563
Barrier #: 71A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61‐1/2" high at room 3169 gas sign
Quantity: EACH
Notes: Also, Braille not 3/8" and max. 1/2" directly below the tactile characters and Braille on signs not located directly below tactile characters
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Microfilm Center 3563
Barrier #: 71B
X Coordinate: N/A
Barrier Area: Counters and Tables
Barrier Type: Workstation ‐ Knee Clearance
Barrier Description:
Knee clearance of at least 27" high, 30" wide and 8" deep not provided
Rec. Solution: Provide min. 1 accessible microfiche reader
Findings:
No knee clearance at 4 microfiche readers
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $875.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 902
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 234
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Microfilm Center 3563
Barrier #: 71C
X Coordinate: N/A
Barrier Area: Counters and Tables
Barrier Type: Workstation ‐ Knee Clearance
Barrier Description:
Knee clearance of at least 27" high, 30" wide and 8" deep not provided
Rec. Solution: Provide min. 1 accessible microfilm scanner
Findings:
No knee clearance at microfilm scanner
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $875.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 902
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Microfilm Center 3563
Barrier #: 71D
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Shelves or Cabinets
Barrier Description:
Shelf or cabinet not mounted max. 48" above floor or ground
Rec. Solution: Provide additional shelf at accessible height or provide assistance
Findings:
Storage drawers higher than 48" high
Quantity: JOB
Notes:
Barrier Severity: 3 Hindrance Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 235
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Map storage Area 3032
Barrier #: 72A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61‐1/2" high at rooms 3012 and 3022
Quantity: EACH
Notes: Also, Braille not 3/8" and max. 1/2" directly below the tactile characters and Braille on signs not located directly below tactile characters. 4 accessible desks provided
Barrier Severity: 1 Necessary Cost Est $500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 2
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Map storage Area 3032
Barrier #: 72B
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Shelves or Cabinets
Barrier Description:
Shelf or cabinet not mounted max. 48" above floor or ground
Rec. Solution: Provide additional shelf at accessible height or provide assistance
Findings:
Storage cabinets higher than 48" high
Quantity: JOB
Notes:
Barrier Severity: 3 Hindrance Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 236
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Map storage Area 3032
Barrier #: 72C
X Coordinate: N/A
Barrier Area: Library Facilities
Barrier Type: Table ‐ Surface Height
Barrier Description:
Surface height exceeds 34" high
Rec. Solution: Provide min. 1 accessible table
Findings:
Light table has 38‐1/2" surface height
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $450.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 902.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Map storage Area 3032
Barrier #: 72D
X Coordinate: N/A
Barrier Area: Library Facilities
Barrier Type: Table ‐ Knee Clearance
Barrier Description:
Knee clearance not min. 27" high, 19" deep or 30" wide
Rec. Solution: Provide min. 1 accessible table
Findings:
9 ‐ 12" deep knee clearance
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 0
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 237
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Map storage Area 3032
Barrier #: 72E
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobes
Findings:
Strobes mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $1,100.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 2
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ East Enclosed Exit Stairway S3710
Barrier #: 73
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Horn/Strobe ‐ Common Use Area
Barrier Description:
No horn/strobes in common use areas
Rec. Solution: Provide strobe in common use area
Findings:
No device provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $5,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702.1
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 238
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Archives and Maps 3032
Barrier #: 74A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Permanent Room/Space ‐ Tactile Characters
Barrier Description:
No tactile characters at sign identifying permanent rooms and spaces with visual signs
Rec. Solution: Provide accessible sign
Findings:
No tactile signage provided at door within public route
Quantity: EACH
Notes: Accessible tables provided
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 216.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ Archives and Maps 3032
Barrier #: 74B
X Coordinate: N/A
Barrier Area: Counters and Tables
Barrier Type: Counter ‐ Surface Height
Barrier Description:
No section at least 3 feet long between 28" and 34" provided at existing counter
Rec. Solution: Provide min. 3 ft long section of counter at max. 34" high
Findings:
Service counter 35‐1/2" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $875.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 902.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 239
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ West Exit Stairway S3010
Barrier #: 75A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Tactile Exit Signs ‐ Stairway
Barrier Description:
Door leading directly into an exit stairway lacks tactile exit sign
Rec. Solution: Provide sign stating “EXIT STAIR DOWN (or UP)” at latch side of door
Findings:
Door to exit stair with low level illuminated sign lacks tactile exit sign
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ West Exit Stairway S3010
Barrier #: 75B
X Coordinate: N/A
Barrier Area: Stairways
Barrier Type: Sign ‐ Enclosed Exit Stairway (Ch 10)
Barrier Description:
Tactile stairway signage incorrectly indicates roof access, info for emergency personnel
Rec. Solution: Move existing sign and provide separate tactile stairway level sign at latch side of door
Findings:
Sign provided is misleading to the visually impaired
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
ICC A117.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 240
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ West Exit Stairway S3010
Barrier #: 75C
X Coordinate: N/A
Barrier Area: Clear Floor Space
Barrier Type: Protruding Object
Barrier Description:
Protruding object in circulation path protrudes more than 4" between 27" and 80" high
Rec. Solution: Remove object or provide detectable warning for the visually impaired
Findings:
Fire riser hose bib protrudes 16‐1/2" at 46" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 3 ‐ West Exit Stairway S3010
Barrier #: 75D
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Horn/Strobe ‐ Common Use Area
Barrier Description:
No horn/strobes in common use areas
Rec. Solution: Provide strobe in common use area
Findings:
No device provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $5,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702.1
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 5 of 8
ADA Assessment and Survey 2014 241
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ East Exit Stairway S4010
Barrier #: 76A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Tactile Exit Signs ‐ Stairway
Barrier Description:
Door leading directly into an exit stairway lacks tactile exit sign
Rec. Solution: Provide sign stating “EXIT STAIR DOWN (or UP)” at latch side of door
Findings:
Door to exit stair with low level illuminated sign lacks tactile exit sign
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ East Exit Stairway S4010
Barrier #: 76B
X Coordinate: N/A
Barrier Area: Stairways
Barrier Type: Sign ‐ Enclosed Exit Stairway (Ch 10)
Barrier Description:
Tactile stairway signage incorrectly indicates roof access, info for emergency personnel
Rec. Solution: Move existing sign and provide separate tactile stairway level sign at latch side of door
Findings:
Sign provided is misleading to the visually impaired
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
ICC A117.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 242
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ East Exit Stairway S4010
Barrier #: 76C
X Coordinate: N/A
Barrier Area: Clear Floor Space
Barrier Type: Protruding Object
Barrier Description:
Protruding object in circulation path protrudes more than 4" between 27" and 80" high
Rec. Solution: Remove object or provide detectable warning for the visually impaired
Findings:
Fire riser hose bib protrudes 14‐1/2" at 46" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ East Exit Stairway S4010
Barrier #: 76D
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Horn/Strobe ‐ Common Use Area
Barrier Description:
No horn/strobes in common use areas
Rec. Solution: Provide strobe in common use area
Findings:
No device provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $5,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702.1
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 243
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Central Hall H4000
Barrier #: 77A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61‐1/2" high at room 4084 and 4200
Quantity: EACH
Notes: Also, Braille on sign not located directly below tactile characters and braille dots on sign not domed or rounded
Barrier Severity: 1 Necessary Cost Est $500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 2
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Central Hall H4000
Barrier #: 77B
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Visual Information Provided (Exhibitions)
Barrier Description:
Visual sign providing information for program, service or activity not accessible
Rec. Solution: Provide information in alternate format to provide access to people with vision impairments
Findings:
Accessible sign not provided
Quantity: JOB
Notes: Artwork exhibited lacks description for visually impaired
Barrier Severity: 1 Necessary Cost Est $5,000.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
ADA Title II Technical Assistance Manual 3.2000 Denial of participation
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 244
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Central Hall H4000
Barrier #: 77C
X Coordinate: N/A
Barrier Area: Elevators
Barrier Type: Hall Call Buttons ‐ 42" High
Barrier Description:
The centerline of the hall call buttons not max. 42" above the floor
Rec. Solution: Replace hall call buttons
Findings:
42‐1/2" high on center
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $3,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 407.2.1
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Central Hall H4000
Barrier #: 77D
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Lobby Info Sign
Barrier Description:
No lobby informational sign with location of accessible elements
Rec. Solution: Provide lobby informational sign
Findings:
Accessible sign not provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 245
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Central Hall H4000
Barrier #: 77E
X Coordinate: N/A
Barrier Area: Corridors
Barrier Type: Lockers ‐ Ratio
Barrier Description:
No accessible locker provided
Rec. Solution: Provide at least 4 accessible lockers
Findings:
62 lockers and none are accessible
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $1,350.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 803
As‐built : 3
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Central Hall H4000
Barrier #: 77F
X Coordinate: N/A
Barrier Area: Corridors
Barrier Type: Lockers ‐ Control
Barrier Description:
Locker mechanism not operable with fist or involves turning and grasping
Rec. Solution: Provide at least 4 accessible lockers
Findings:
Lock mechanisms not accessible
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 803.5
As‐built : 0
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 246
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Central Hall H4000
Barrier #: 77G
X Coordinate: N/A
Barrier Area: Corridors
Barrier Type: Strobe Height ‐ 80" on Wall
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobes
Findings:
Strobes mounted 77‐1/2" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $2,200.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 4
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Library Catalogue Area 4062
Barrier #: 78A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Permanent Room/Space ‐ Tactile Characters
Barrier Description:
No tactile characters at sign identifying permanent rooms and spaces with visual signs
Rec. Solution: Provide accessible sign
Findings:
No tactile signage provided at door within public route
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 216.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 247
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Library Catalogue Area 4062
Barrier #: 78B
X Coordinate: N/A
Barrier Area: Counters and Tables
Barrier Type: Counter ‐ Knee Clearance
Barrier Description:
Knee clearance not min. 27" high, 19" deep or 30" wide
Rec. Solution: Provide min. 3 ft segment of accessible counter with min. 1 PC terminal for use
Findings:
No knee clearance at counter
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $875.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Library Catalogue Area 4062
Barrier #: 78C
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Electrical Outlets ‐ Side Reach Obstructed (10"‐24")
Barrier Description:
Outlet located over an 10" to 24" obstruction max. 34" high located above 46"
Rec. Solution: Relocate control or mechanism to max. 46" high
Findings:
Power strip below desk surface hanging along back wall at accessible computer carrel
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 248
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Library Catalogue Area 4062
Barrier #: 78D
X Coordinate: N/A
Barrier Area: Library Facilities
Barrier Type: Desk ‐ Surface Height
Barrier Description:
Surface height exceeds 34" high
Rec. Solution: Provide accessible desk or workstation
Findings:
38" surface height
Quantity: EACH
Notes: Adjustable desk for videophone not adjustable manually
Barrier Severity: 3 Hindrance Cost Est $875.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 902.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Library Stacks 4031
Barrier #: 79A
X Coordinate: N/A
Barrier Area: Clear Floor Space
Barrier Type: Passageway ‐ Min. 36"
Barrier Description:
Circulation route not min. 36" wide between elements
Rec. Solution: Rearrange stacks to provide accessble circulation route
Findings:
36" wide circulation route between double sided stacks in multiple locations
Quantity: LF
Notes: Accessible study carrels provided
Barrier Severity: 1 Necessary Cost Est $2,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 403.5.1
As‐built : 20
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 249
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Library Stacks 4031
Barrier #: 79B
X Coordinate: N/A
Barrier Area: Library Facilities
Barrier Type: Desk ‐ Surface Height
Barrier Description:
Surface height exceeds 34" high
Rec. Solution: Provide min. 1 accessible dictionary stand surface
Findings:
Dictionary stand surface 42" ‐ 48" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $875.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 902.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Library Stacks 4031
Barrier #: 79C
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobes
Findings:
Strobes mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $5,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 10
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 250
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Rotunda Area 4099
Barrier #: 80A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Permanent Room/Space ‐ Tactile Characters
Barrier Description:
No tactile characters at sign identifying permanent rooms and spaces with visual signs
Rec. Solution: Provide accessible sign
Findings:
No tactile signage provided at door within public route
Quantity: EACH
Notes: Accessible tables provided
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 216.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Rotunda Area 4099
Barrier #: 80B
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 251
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Admin & Consulting Services 4062
Barrier #: 81A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61‐1/2" high
Quantity: EACH
Notes: Also, braille not 3/8" and max. 1/2" directly below the tactile characters and braille dots on sign not domed or rounded
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Admin & Consulting Services 4062
Barrier #: 81B
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Automatic Doors ‐ Sign
Barrier Description:
ISA symbol at automatic door opening device not min. 4" x 4" in size
Rec. Solution: Recommended: Provide ISA symbol min. 4" x 4" in size
Findings:
No ISA sign at automatic door actuator
Quantity: JOB
Notes:
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 252
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Admin & Consulting Services 4062
Barrier #: 81C
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Automatic Doors ‐ BHMA Sign
Barrier Description:
No sign on door visible from both sides reading, "AUTOMATIC DOOR"
Rec. Solution: Provide new sign on both sides of door
Findings:
No BHMA sign on door
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
ANSI/BHMA A156.10‐1999
As‐built : 2
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Admin & Consulting Services 4062
Barrier #: 81D
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ Within 18" of Door
Barrier Description:
Approach to tactile characters on sign not centered at 18" minimum from door swing
Rec. Solution: Relocate sign or replace
Findings:
Tactile sign 60" from door swing
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $150.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 253
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Admin & Consulting Services 4062
Barrier #: 81E
X Coordinate: N/A
Barrier Area: Counters and Tables
Barrier Type: Counter ‐ Surface Height
Barrier Description:
No section at least 3 feet long between 28" and 34" provided at existing counter
Rec. Solution: Remove stored items from accessible section of counter
Findings:
Computers and other items block accessible counter clear floor space
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 902.3
As‐built : 0
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Admin & Consulting Services 4062
Barrier #: 81F
X Coordinate: N/A
Barrier Area: Counters and Tables
Barrier Type: Counter ‐ Protruding Object
Barrier Description:
Counter or table in route of travel protrudes more than 4" above 27" high
Rec. Solution: Provide cane‐detectable warning that reaches below 27" high for the visually impaired
Findings:
6" protrusion at 3 counters
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $1,650.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307
As‐built : 3
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 254
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Admin & Consulting Services 4062
Barrier #: 81G
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Corridor H4500
Barrier #: 82A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61" high at rooms 4500, 4443 and 4149
Quantity: EACH
Notes: Also, braille not 3/8" and max. 1/2" directly below the tactile characters and braille dots on signs not domed or rounded
Barrier Severity: 1 Necessary Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 3
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 255
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Corridor H4500
Barrier #: 82B
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Interior
Barrier Description:
Door opening force exceeds 5 lbf
Rec. Solution: Provide automatic door opening devices
Findings:
9 and 12 lbf
Quantity: EACH
Notes: Door at end of corridor and door to corridor
Barrier Severity: 1 Necessary Cost Est $10,000.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.9
As‐built : 2
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Corridor H4500
Barrier #: 82C
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Sweep Period
Barrier Description:
Door closer lacks min. 5 second sweep period
Rec. Solution: Provide automatic door opening devices
Findings:
3 second sweep
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.8.1
As‐built : 0
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 256
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Corridor H4500
Barrier #: 82D
X Coordinate: N/A
Barrier Area: Corridors
Barrier Type: Strobe Height ‐ 80" on Wall
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Office Space 4450
Barrier #: 83A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61" ‐ 62" high at phone booth 4958 used for private calls and room 4450
Quantity: EACH
Notes: Also, braille not 3/8" and max. 1/2" directly below the tactile characters and Braille dots on sign not domed or rounded
Barrier Severity: 1 Necessary Cost Est $500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 2
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 257
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Office Space 4450
Barrier #: 83B
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Interior
Barrier Description:
Door opening force exceeds 5 lbf
Rec. Solution: Provide automatic door opening device
Findings:
11 lbf
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $5,000.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.9
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Office Space 4450
Barrier #: 83C
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Sweep Period
Barrier Description:
Door closer lacks min. 5 second sweep period
Rec. Solution: Provide automatic door opening device
Findings:
3 second sweep
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.8.1
As‐built : 0
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 258
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Office Space 4450
Barrier #: 83D
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Tactile Exit Signs ‐ Passage
Barrier Description:
Exit thru an exit enclosure/exit passageway lacks tactile exit sign
Rec. Solution: Provide sign stating “EXIT ROUTE” at exit side of door
Findings:
Passageway to exterior exit with low level illuminated sign lacks tactile exit sign
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Office Space 4450
Barrier #: 83E
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Electrical Switches ‐ Height
Barrier Description:
Light switch control box top edge not at max. 48" high
Rec. Solution: Relocate switch box top edge to max. 48" high
Findings:
50" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 308.2
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 259
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Office Space 4450
Barrier #: 83F
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Office Room 4754
Barrier #: 84A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61‐1/2" high
Quantity: EACH
Notes: Also, Braille on sign not located directly below tactile characters and braille dots on sign not domed or rounded
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 260
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Office Room 4754
Barrier #: 84B
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Electrical Switches ‐ Height
Barrier Description:
Light switch control box top edge not at max. 48" high
Rec. Solution: Relocate switch box top edge to max. 48" high
Findings:
50" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 308.2
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Office Room 4754
Barrier #: 84C
X Coordinate: N/A
Barrier Area: Counters and Tables
Barrier Type: Table ‐ Pedestal Base
Barrier Description:
Knee clearance not min. 27" high, 19" deep or 30" wide
Rec. Solution: Provide min. 1 accessible table. Avoid pedestal base tables
Findings:
Pedestal base blocks knee clearance
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $450.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 306.2.2 and 306.2.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 261
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Office Room 4754
Barrier #: 84D
X Coordinate: N/A
Barrier Area: Counters and Tables
Barrier Type: Desk ‐ Knee Clearance
Barrier Description:
Knee clearance not min. 27" high, 19" deep or 30" wide
Rec. Solution: Provide accessible desk or workstation
Findings:
No knee clearance for desk but adequate maneuvering to rest in front of desk
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $875.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 902.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Office Room 4754
Barrier #: 84E
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 262
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Conference Room 4960
Barrier #: 85A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
62" high
Quantity: EACH
Notes: Also, braille not 3/8" and max. 1/2" directly below the tactile characters and Braille on signs not domed or rounded
Barrier Severity: 1 Necessary Cost Est $500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 2
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Conference Room 4960
Barrier #: 85B
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Clear Floor Space ‐ Stored Elements
Barrier Description:
Clear floor space for wheelchair not provided at control or mechanism
Rec. Solution: Move stored items
Findings:
Chairs block whiteboard clear floor space
Quantity: JOB
Notes:
Barrier Severity: 1 Necessary Cost Est $125.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 263
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Conference Room 4960
Barrier #: 85C
X Coordinate: N/A
Barrier Area: Assembly Areas
Barrier Type: Shared Assistive Listening System
Barrier Description:
No shared assistive listening system for room with min. 10 seats
Rec. Solution: Provide shared ALS system
Findings:
No indication of shared assistive listening system
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Conference Room 4960
Barrier #: 85D
X Coordinate: N/A
Barrier Area: Counters and Tables
Barrier Type: Table ‐ Knee Clearance
Barrier Description:
Knee clearance not min. 27" high, 19" deep or 30" wide
Rec. Solution: Provide min. 1 accessible table
Findings:
26‐1/2" high and 14" deep knee clearance
Quantity: EACH
Notes: Tables may be adjustable but none of the 6 existing tables are adjusted for access
Barrier Severity: 3 Hindrance Cost Est $450.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 264
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Conference Room 4960
Barrier #: 85E
X Coordinate: N/A
Barrier Area: Counters and Tables
Barrier Type: Table ‐ Knee Clearance
Barrier Description:
Knee clearance not min. 27" high, 19" deep or 30" wide
Rec. Solution: Provide min. 1 accessible table
Findings:
Side table has 24" high knee clearance
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $450.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Conference Room 4960
Barrier #: 85F
X Coordinate: N/A
Barrier Area: Clear Floor Space
Barrier Type: Protruding Object
Barrier Description:
Protruding object in circulation path protrudes more than 4" between 27" and 80" high
Rec. Solution: Remove object or provide detectable warning for the visually impaired
Findings:
Shelf at monitor protrudes 21" at 43‐1/2" high.Monitor protrudes more than 4"
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 265
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Conference Room 4960
Barrier #: 85G
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ East West Corridor H4700
Barrier #: 86A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61" ‐ 62" high at rooms 4788, 4850, 4600 and 4771
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $1,000.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 4
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 266
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ East West Corridor H4700
Barrier #: 86B
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61" ‐ 62" high
Quantity: EACH
Notes: Rooms 4761, 4445, 4747, 4743, 4737, 4429, 4427, 4425, 4722 and 4743. Also, braille not 3/8" and max. 1/2" directly below the tactile characters and braille dots on signs not domed or rounded
Barrier Severity: 1 Necessary Cost Est $2,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 10
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ East West Corridor H4700
Barrier #: 86C
X Coordinate: N/A
Barrier Area: Corridors
Barrier Type: Strobe Height ‐ 80" on Wall
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobes
Findings:
Strobes not at least 80" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $1,650.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 3
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 267
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Southwest Exit Stairway S4710
Barrier #: 87A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61‐1/2" high, Existing sign states "STAIR"
Quantity: EACH
Notes: Also, braille dots on sign not domed or rounded
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Southwest Exit Stairway S4710
Barrier #: 87B
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Interior Adjustment
Barrier Description:
Door opening force exceeds 5 lbf
Rec. Solution: Replace or adjust existing closer. Door does not lead to an accessible route
Findings:
18 lbf
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $450.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.9
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 268
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Southwest Exit Stairway S4710
Barrier #: 87C
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Sweep Period
Barrier Description:
Door closer lacks min. 5 second sweep period
Rec. Solution: Replace or adjust existing closer. Door does not lead to an accessible route
Findings:
3 second sweep
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.8.1
As‐built : 0
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Southwest Exit Stairway S4710
Barrier #: 87D
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Tactile Exit Signs ‐ Stairway
Barrier Description:
Door leading directly into an exit stairway lacks tactile exit sign
Rec. Solution: Provide sign stating “EXIT STAIR DOWN (or UP)” at latch side of door
Findings:
Door to exit stair with low level illuminated sign lacks tactile exit sign
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 269
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Southwest Exit Stairway S4710
Barrier #: 87E
X Coordinate: N/A
Barrier Area: Stairways
Barrier Type: Sign ‐ Enclosed Exit Stairway (Ch 10)
Barrier Description:
Tactile stairway signage incorrectly indicates roof access, info for emergency personnel
Rec. Solution: Move existing sign and provide separate tactile stairway level sign at latch side of door
Findings:
Sign provided is misleading to the visually impaired
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
ICC A117.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Southwest Exit Stairway S4710
Barrier #: 87F
X Coordinate: N/A
Barrier Area: Clear Floor Space
Barrier Type: Protruding Object
Barrier Description:
Protruding object in circulation path protrudes more than 4" between 27" and 80" high
Rec. Solution: Remove object or provide detectable warning for the visually impaired
Findings:
Fire hose bib protrudes 6" at 42" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 270
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Southwest Exit Stairway S4710
Barrier #: 87G
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Horn/Strobe ‐ Common Use Area
Barrier Description:
No horn/strobes in common use areas
Rec. Solution: Provide strobe in common use area
Findings:
No device provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $5,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702.1
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Exit Lobby L4711
Barrier #: 88A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61" high or higher at rooms 4711 and 4715
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 2
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 271
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Exit Lobby L4711
Barrier #: 88B
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Interior Automatic Door
Barrier Description:
Door opening force exceeds 5 lbf
Rec. Solution: Provide automatic door opening device
Findings:
18 lbf
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $5,000.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.9
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Exit Lobby L4711
Barrier #: 88C
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Sweep Period
Barrier Description:
Door closer lacks min. 5 second sweep period
Rec. Solution: Provide automatic door opening device
Findings:
3 second sweep
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.8.1
As‐built : 0
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 272
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Exit Lobby L4711
Barrier #: 88D
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Electrical Switches ‐ Height
Barrier Description:
Light switch control box top edge not at max. 48" high
Rec. Solution: Relocate switch box top edge to max. 48" high
Findings:
50" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 308.2
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Exit Lobby L4711
Barrier #: 88E
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes: Elevator is accessible
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 273
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Kitchenette Area 4700
Barrier #: 89A
X Coordinate: N/A
Barrier Area: Counters and Tables
Barrier Type: Counter ‐ Surface Height
Barrier Description:
No section at least 3 feet long between 28" and 34" provided at existing counter
Rec. Solution: Provide min. 3 ft long section of counter at max. 34" high
Findings:
36" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $875.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 902.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Kitchenette Area 4700
Barrier #: 89B
X Coordinate: N/A
Barrier Area: Kitchens
Barrier Type: Faucet ‐ Operation
Barrier Description:
Faucets lack controls and operating mechanisms involve tight grasping, pinching or twisting of the wrist
Rec. Solution: Replace faucet
Findings:
Faucet is not fist operable and faucets not operable due to location of sinkerator device
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $275.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 804.4 & 606.4
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 274
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Kitchenette Area 4700
Barrier #: 89C
X Coordinate: N/A
Barrier Area: Kitchens
Barrier Type: Sink ‐ Rim
Barrier Description:
Sinks not mounted with the counter or rim no higher than 34" above the finish floor
Rec. Solution: Remount sink
Findings:
36" high AFF
Quantity: LF
Notes:
Barrier Severity: 1 Necessary Cost Est $375.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 606.3
As‐built : 3
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Kitchenette Area 4700
Barrier #: 89D
X Coordinate: N/A
Barrier Area: Kitchens
Barrier Type: Sink ‐ Knee Clearance
Barrier Description:
Knee clearance of at least 27" high, 30" wide and 8" deep not provided underneath sink
Rec. Solution: Replace cabinet and remount sink if needed
Findings:
7‐1/2" deep knee clearance
Quantity: LF
Notes:
Barrier Severity: 1 Necessary Cost Est $1,350.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 804.4 & 606.2
As‐built : 3
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 275
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Kitchenette Area 4700
Barrier #: 89E
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Electrical Outlets ‐ Side Reach Obstructed (10"‐24")
Barrier Description:
Outlet located over an 10" to 24" obstruction max. 34" high located above 46"
Rec. Solution: Relocate control or mechanism to max. 46" high
Findings:
46" high and 21" deep over an obstruction 36" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Kitchenette Area 4700
Barrier #: 89F
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Actuator/Control ‐ Side Reach Obstructed (10"‐24")
Barrier Description:
Control or mechanism over an 10" to 24" obstruction max. 34" high located above 46"
Rec. Solution: Relocate control or mechanism to max. 46" high
Findings:
Soap and paper towel dispenser 46" to 49" high and 21" deep over an obstruction 36" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 276
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Kitchenette Area 4700
Barrier #: 89G
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Shelves or Cabinets
Barrier Description:
Shelf or cabinet not mounted max. 48" above floor or ground
Rec. Solution: Provide additional shelf at accessible height or provide assistance
Findings:
Shelf higher than 48" high
Quantity: JOB
Notes:
Barrier Severity: 3 Hindrance Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Exit Corridor H4790
Barrier #: 90A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61" high at room 4700
Quantity: EACH
Notes: Also, braille dots on sign not domed or rounded
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 277
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Exit Corridor H4790
Barrier #: 90B
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Tactile Exit Signs ‐ Passage
Barrier Description:
Exit thru an exit enclosure/exit passageway lacks tactile exit sign
Rec. Solution: Provide sign stating “EXIT ROUTE” at exit side of door
Findings:
No tactile exit sign at door from office space
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Exit Corridor H4790
Barrier #: 90C
X Coordinate: N/A
Barrier Area: Corridors
Barrier Type: Strobe Height ‐ 80" on Wall
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 278
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Exit Corridor H4790
Barrier #: 90D
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61‐1/2" high at stairway S4790. Existing sign states "STAIR" sign
Quantity: EACH
Notes: Also, braille dots on sign not domed or rounded
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Exit Corridor H4790
Barrier #: 90E
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Interior Adjustment
Barrier Description:
Door opening force exceeds 5 lbf
Rec. Solution: Replace or adjust existing closer. Door does not lead to an accessible route
Findings:
18 lbf
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $450.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.9
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 279
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Exit Corridor H4790
Barrier #: 90F
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Sweep Period
Barrier Description:
Door closer lacks min. 5 second sweep period
Rec. Solution: Replace or adjust existing closer. Door does not lead to an accessible route
Findings:
2 second sweep
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.8.1
As‐built : 0
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Exit Corridor H4790
Barrier #: 90G
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Tactile Exit Signs ‐ Stairway
Barrier Description:
Door leading directly into an exit stairway lacks tactile exit sign
Rec. Solution: Provide sign stating “EXIT STAIR DOWN (or UP)” at latch side of door
Findings:
No tactile exit sign for stair. Existing sign states "STAIR"
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 280
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Exit Corridor H4790
Barrier #: 90H
X Coordinate: N/A
Barrier Area: Stairways
Barrier Type: Sign ‐ Enclosed Exit Stairway (Ch 10)
Barrier Description:
Tactile stairway signage incorrectly indicates roof access, info for emergency personnel
Rec. Solution: Move existing sign and provide separate tactile stairway level sign at latch side of door
Findings:
Sign provided is misleading to the visually impaired
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
ICC A117.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Exit Corridor H4790
Barrier #: 90I
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Horn/Strobe ‐ Common Use Area
Barrier Description:
No horn/strobes in common use areas
Rec. Solution: Provide strobe in common use area
Findings:
No device provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $5,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702.1
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 281
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Elevator/Restroom Corridor H4500
Barrier #: 91A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Permanent Room/Space ‐ Tactile Characters
Barrier Description:
No tactile characters at sign identifying permanent rooms and spaces with visual signs
Rec. Solution: Provide accessible sign
Findings:
Overhead visual sign on one side
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 216.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Elevator/Restroom Corridor H4500
Barrier #: 91B
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61" high
Quantity: EACH
Notes: Rooms 4567, 4500 doorway, 4561, 4562, 4563 and 4564. Also, Room 4562 sign characters and their background lack a non‐glare finish. Braille on sign at 4562 is damaged
Barrier Severity: 1 Necessary Cost Est $1,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 6
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 282
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Elevator/Restroom Corridor H4500
Barrier #: 91C
X Coordinate: N/A
Barrier Area: Drinking Fountains
Barrier Type: Alcove ‐ New Construction
Barrier Description:
Fountain with a leading edge between 27" and 80" high protrudes more than 4" into the circulation path.
Rec. Solution: Demolish and construct new alcove as detectable warning
Findings:
Hi‐Low drinking fountain not completely inside alcove
Quantity: SF
Notes:
Barrier Severity: 1 Necessary Cost Est $2,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307.2
As‐built : 10
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Elevator/Restroom Corridor H4500
Barrier #: 91D
X Coordinate: N/A
Barrier Area: Drinking Fountains
Barrier Type: Operation ‐ Replacement
Barrier Description:
Operating mechanism involves more than 5 lbf to operate
Rec. Solution: Replace drinking fountain with accessible unit
Findings:
Needed more than 5 lbf where fountain is not adjustable
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 602.3
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 283
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Elevator/Restroom Corridor H4500
Barrier #: 91E
X Coordinate: N/A
Barrier Area: Drinking Fountains
Barrier Type: Knee Clearance
Barrier Description:
Knee clearance under fountain not min. 27" high
Rec. Solution: Replace drinking fountain with accessible unit or remount existing
Findings:
26‐1/2" high knee clearance
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 306.3
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Elevator/Restroom Corridor H4500
Barrier #: 91F
X Coordinate: N/A
Barrier Area: Counters and Tables
Barrier Type: Counter ‐ Surface Height
Barrier Description:
No section at least 3 feet long between 28" and 34" provided at existing counter
Rec. Solution: Provide min. 3 ft long section of counter at max. 34" high
Findings:
Work counter 35‐1/2" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $875.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 902.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 284
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Women's Restroom 4566
Barrier #: 92A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
62" high
Quantity: EACH
Notes: Also, Braille not 3/8" and max. 1/2" directly below the tactile characters and Braille dots on sign not domed or rounded
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Women's Restroom 4566
Barrier #: 92B
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Interior
Barrier Description:
Door opening force exceeds 5 lbf
Rec. Solution: Provide automatic door opening device
Findings:
18 lbf
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $5,000.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.9
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 285
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Women's Restroom 4566
Barrier #: 92C
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Sweep Period
Barrier Description:
Door closer lacks min. 5 second sweep period
Rec. Solution: Provide automatic door opening device
Findings:
2 second sweep
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.8.1
As‐built : 0
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Women's Restroom 4566
Barrier #: 92D
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Dispensers ‐ Protruding Object
Barrier Description:
Protruding dispenser creates protruding hazard in path of travel
Rec. Solution: Remove dispensers or provide detectable warning for the visually impaired
Findings:
Feminine product dispensers protrude 6" at 42" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $1,100.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307.2
As‐built : 2
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 286
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Women's Restroom 4566
Barrier #: 92E
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Dispensers ‐ Sanitary Products
Barrier Description:
Feminine product dispenser does not operate at 5 lbf or less
Rec. Solution: Replace dispensers
Findings:
Exceed 5 lbf
Quantity: EACH
Notes: 2 of 2 feminine product dispensers
Barrier Severity: 1 Necessary Cost Est $650.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 603.3
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Women's Restroom 4566
Barrier #: 92F
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Electrical Outlets ‐ Forward Reach Obstructed (10"‐25")
Barrier Description:
Outlet located over an 10" to 25" obstruction max. 34" high located above 44"
Rec. Solution: Relocate control or mechanism to max. 44" high
Findings:
44" high and 22" deep
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 308.2.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 287
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Women's Restroom 4566
Barrier #: 92G
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Stall ‐ Door Hardware
Barrier Description:
Inside of compartment door lacks a loop or U‐pull below latch
Rec. Solution: Provide hardware
Findings:
No U‐pull provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $75.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.8.1.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Women's Restroom 4566
Barrier #: 92H
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Seat Cover Dispenser
Barrier Description:
Seat cover dispenser not located on an accessible route. Blocked by water closet
Rec. Solution: Replace or remount dispenser on an accessible route with clear floor space
Findings:
Access to dispenser blocked by water closet
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $125.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 288
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Women's Restroom 4566
Barrier #: 92I
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Centerline
Barrier Description:
Water closet centerline not between 16" and 18" O. C.
Rec. Solution: Relocate water closet
Findings:
18‐3/4" on center
Quantity: JOB
Notes:
Barrier Severity: 3 Hindrance Cost Est $850.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Women's Restroom 4566
Barrier #: 92J
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Paper Dispenser
Barrier Description:
Toilet tissue dispenser not within 7" to 9" from front edge of toilet
Rec. Solution: Reposition or replace toilet paper dispenser
Findings:
14" from front edge of toilet
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $225.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.7
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 289
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Women's Restroom 4566
Barrier #: 92K
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Men's Restroom 4569
Barrier #: 93A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
62" high
Quantity: EACH
Notes: Also, Braille not 3/8" and max. 1/2" directly below the tactile characters and Braille dots on sign not domed or rounded
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 290
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Men's Restroom 4569
Barrier #: 93B
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Interior
Barrier Description:
Door opening force exceeds 5 lbf
Rec. Solution: Provide automatic door opening device
Findings:
18 lbf
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $5,000.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.9
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Men's Restroom 4569
Barrier #: 93C
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Sweep Period
Barrier Description:
Door closer lacks min. 5 second sweep period
Rec. Solution: Provide automatic door opening device
Findings:
2 second sweep
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.8.1
As‐built : 0
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 291
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Men's Restroom 4569
Barrier #: 93D
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Dispensers ‐ Protruding Object
Barrier Description:
Protruding dispenser creates protruding hazard in path of travel
Rec. Solution: Remove dispenser or provide detectable warning for the visually impaired
Findings:
Paper towel dispenser protrudes 10" at 44" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307.2
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Men's Restroom 4569
Barrier #: 93E
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Lavatory ‐ Rim Height
Barrier Description:
Lavatory rim or counter edge is higher than 34" AFF
Rec. Solution: Provide min. 1 accessible lavatory
Findings:
34‐1/3" high AFF
Quantity: JOB
Notes:
Barrier Severity: 1 Necessary Cost Est $450.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 606.3
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 292
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Men's Restroom 4569
Barrier #: 93F
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Lavatory ‐ Knee Clearance
Barrier Description:
Lavatory bottom apron/edge not max 29" reducing to 27" at 8" back from edge
Rec. Solution: Remove cover at drainpipes
Findings:
7" deep knee clearance
Quantity: JOB
Notes:
Barrier Severity: 1 Necessary Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 606.2 & 306
As‐built : 0
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Men's Restroom 4569
Barrier #: 93G
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Electrical Outlets ‐ Forward Reach Obstructed (10"‐25")
Barrier Description:
Outlet located over an 10" to 25" obstruction max. 34" high located above 44"
Rec. Solution: Relocate control or mechanism to max. 44" high
Findings:
44" high and 20" deep over an obstruction 34‐1/4" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 308.2.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 293
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Men's Restroom 4569
Barrier #: 93H
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Urinal ‐ Rim
Barrier Description:
Min. 1 urinal has no elongated rim projecting 14" to 17" from wall
Rec. Solution: Provide min. 1 accessible urinal
Findings:
13" deep urinal
Quantity: JOB
Notes:
Barrier Severity: 2 Recommended Cost Est $800.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 605.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Men's Restroom 4569
Barrier #: 93I
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Stall Door Closer
Barrier Description:
Stall door not equipped with an automatic closing device
Rec. Solution: Replace compartment hinge with adjustible mechanism
Findings:
Stall door not self‐closing
Quantity: JOB
Notes:
Barrier Severity: 2 Recommended Cost Est $1,650.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.8.1.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 294
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Men's Restroom 4569
Barrier #: 93J
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Stall ‐ Door Hardware
Barrier Description:
Outside of compartment door lacks a loop or U‐pull below latch
Rec. Solution: Provide hardware
Findings:
No U‐pull provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $75.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.8.1.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Men's Restroom 4569
Barrier #: 93K
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Stall ‐ Door Hardware
Barrier Description:
Inside of compartment door lacks a loop or U‐pull below latch
Rec. Solution: Provide hardware
Findings:
No U‐pull provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $75.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.8.1.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 295
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Men's Restroom 4569
Barrier #: 93L
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Seat Cover Dispenser
Barrier Description:
Seat cover dispenser not located on an accessible route. Blocked by water closet
Rec. Solution: Replace or remount dispenser on an accessible route with clear floor space
Findings:
Access to dispenser blocked by water closet
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $125.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Men's Restroom 4569
Barrier #: 93M
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Centerline
Barrier Description:
Water closet centerline not between 16" and 18" O. C.
Rec. Solution: Relocate water closet
Findings:
18‐3/4" on center
Quantity: JOB
Notes:
Barrier Severity: 3 Hindrance Cost Est $850.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 296
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Men's Restroom 4569
Barrier #: 93N
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Paper Dispenser
Barrier Description:
Toilet tissue dispenser not within 7" to 9" from front edge of toilet
Rec. Solution: Reposition or replace toilet paper dispenser
Findings:
14" from front edge of toilet
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $225.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.7
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Men's Restroom 4569
Barrier #: 93O
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 297
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Corridor H4600
Barrier #: 94A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61" high
Quantity: EACH
Notes: Rooms 4600, 4605 and 4615. Also, Braille dots on signs not domed or rounded. For Room 4605 and Braille not 3/8" and max. 1/2" directly below the tactile characters
Barrier Severity: 1 Necessary Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 3
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Corridor H4600
Barrier #: 94B
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Interior
Barrier Description:
Door opening force exceeds 5 lbf
Rec. Solution: Provide automatic door opening device
Findings:
9 lbf at door at end of corridor
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $5,000.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.9
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 298
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Corridor H4600
Barrier #: 94C
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Sweep Period
Barrier Description:
Door closer lacks min. 5 second sweep period
Rec. Solution: Provide automatic door opening device
Findings:
3 second sweep
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.8.1
As‐built : 0
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Corridor H4600
Barrier #: 94D
X Coordinate: N/A
Barrier Area: Corridors
Barrier Type: Strobe Height ‐ 80" on Wall
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 299
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Kitchenette Area 4600
Barrier #: 95A
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Electrical Switches ‐ Height
Barrier Description:
Light switch control box top edge not at max. 48" high
Rec. Solution: Relocate switch box top edge to max. 48" high
Findings:
50" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 308.2
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Kitchenette Area 4600
Barrier #: 95B
X Coordinate: N/A
Barrier Area: Counters and Tables
Barrier Type: Counter ‐ Surface Height
Barrier Description:
No section at least 3 feet long between 28" and 34" provided at existing counter
Rec. Solution: Provide min. 3 ft long section of counter at max. 34" high
Findings:
Kitchenette counter 36" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $875.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 902.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 300
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Kitchenette Area 4600
Barrier #: 95C
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Actuator/Control ‐ Side Reach Obstructed (10"‐24")
Barrier Description:
Control or mechanism over an 10" to 24" obstruction max. 34" high located above 46"
Rec. Solution: Relocate control or mechanism to max. 46" high
Findings:
Soap and paper towel dispenser 46" high and 21" deep over an obstruction 36" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Kitchenette Area 4600
Barrier #: 95D
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Electrical Outlets ‐ Side Reach Obstructed (10"‐24")
Barrier Description:
Outlet located over an 10" to 24" obstruction max. 34" high located above 46"
Rec. Solution: Relocate control or mechanism to max. 46" high
Findings:
46" high and 21" deep over an obstruction 36" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 301
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Kitchenette Area 4600
Barrier #: 95E
X Coordinate: N/A
Barrier Area: Classrooms
Barrier Type: Sink ‐ Faucet
Barrier Description:
Faucets lack controls and operating mechanisms involve tight grasping, pinching or twisting of the wrist
Rec. Solution: Replace faucets
Findings:
Faucet not fist operable due to location of sinkerator device
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $275.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 606.4 & 309
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Kitchenette Area 4600
Barrier #: 95F
X Coordinate: N/A
Barrier Area: Classrooms
Barrier Type: Sink ‐ Rim or Countertop
Barrier Description:
Sink rim or surface not max. 34" high
Rec. Solution: Reposition existing sink or provide additional sinks for use in area
Findings:
36" high
Quantity: LF
Notes:
Barrier Severity: 1 Necessary Cost Est $1,110.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 606.3
As‐built : 3
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 302
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Kitchenette Area 4600
Barrier #: 95G
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Shelves or Cabinets
Barrier Description:
Shelf or cabinet not mounted max. 48" above floor or ground
Rec. Solution: Provide additional shelf at accessible height or provide assistance
Findings:
Shelf higher than 48" high
Quantity: JOB
Notes:
Barrier Severity: 3 Hindrance Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Conference Room 4168
Barrier #: 96A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61‐1/2" high
Quantity: EACH
Notes: Also, braille not 3/8" and max. 1/2" directly below the tactile characters and braille dots on sign not domed or rounded
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 303
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Conference Room 4168
Barrier #: 96B
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Actuator/Control ‐ Hi/low Reach
Barrier Description:
Use of control involves low reach of less than 15" above floor or more than 48" high
Rec. Solution: Relocate to area at min. 15" or max. 48" high
Findings:
No shared assistive listening system
Quantity: EACH
Notes: No shared assistive listening system. Table is accessible
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 308.2.2
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Conference Room 4168
Barrier #: 96C
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 304
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Office Room 4165
Barrier #: 97A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61‐1/2" high
Quantity: EACH
Notes: Also, braille not 3/8" and max. 1/2" directly below the tactile characters and braille dots on sign not domed or rounded
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Office Room 4165
Barrier #: 97B
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Electrical Switches ‐ Height
Barrier Description:
Light switch control box top edge not at max. 48" high
Rec. Solution: Relocate switch box top edge to max. 48" high
Findings:
50" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 308.2
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 305
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Office Room 4165
Barrier #: 97C
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Coat Hook ‐ Height
Barrier Description:
Clothing hooks not max. 48" high AFF
Rec. Solution: Provide additional hook
Findings:
Coat stand over 48" high
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $125.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 308.2
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Office Room 4165
Barrier #: 97D
X Coordinate: N/A
Barrier Area: Counters and Tables
Barrier Type: Table ‐ Knee Clearance
Barrier Description:
Knee clearance not min. 27" high, 19" deep or 30" wide
Rec. Solution: Provide min. 1 accessible table
Findings:
No knee clearance
Quantity: EACH
Notes: Pedestal table
Barrier Severity: 3 Hindrance Cost Est $450.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 306
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Office Room 4165
Barrier #: 97E
X Coordinate: N/A
Barrier Area: Counters and Tables
Barrier Type: Table ‐ Pedestal Base
Barrier Description:
Knee clearance not min. 27" high, 19" deep or 30" wide
Rec. Solution: Provide min. 1 accessible table. Avoid pedestal base tables
Findings:
Pedestal base blocks knee clearance
Quantity: EACH
Notes: Pedestal based table
Barrier Severity: 2 Recommended Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 306.2.2 and 306.2.3
As‐built : 0
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Office Room 4165
Barrier #: 97F
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 307
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Staff Entry Corridor H4160
Barrier #: 98A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61‐1/2" high
Quantity: EACH
Notes: Also, braille dots on sign not domed or rounded
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Staff Entry Corridor H4160
Barrier #: 98B
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Interior
Barrier Description:
Door opening force exceeds 5 lbf
Rec. Solution: Provide automatic door opening device
Findings:
12 lbf
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $5,000.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.9
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 308
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Staff Entry Corridor H4160
Barrier #: 98C
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Sweep Period
Barrier Description:
Door closer lacks min. 5 second sweep period
Rec. Solution: Provide automatic door opening device
Findings:
2 second sweep
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.8.1
As‐built : 0
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ Staff Entry Corridor H4160
Barrier #: 98D
X Coordinate: N/A
Barrier Area: Corridors
Barrier Type: Strobe Height ‐ 80" on Wall
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 309
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ West Exit Stairway S4090
Barrier #: 99A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Tactile Exit Signs ‐ Stairway
Barrier Description:
Door leading directly into an exit stairway lacks tactile exit sign
Rec. Solution: Provide sign stating “EXIT STAIR DOWN (or UP)” at latch side of door
Findings:
Door to exit stair with low level illuminated sign lacks tactile exit sign
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ West Exit Stairway S4090
Barrier #: 99B
X Coordinate: N/A
Barrier Area: Stairways
Barrier Type: Sign ‐ Enclosed Exit Stairway (Ch 10)
Barrier Description:
Tactile stairway signage incorrectly indicates roof access, info for emergency personnel
Rec. Solution: Move existing sign and provide separate tactile stairway level sign at latch side of door
Findings:
Sign provided is misleading to the visually impaired
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
ICC A117.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 310
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ West Exit Stairway S4090
Barrier #: 99C
X Coordinate: N/A
Barrier Area: Clear Floor Space
Barrier Type: Protruding Object
Barrier Description:
Protruding object in circulation path protrudes more than 4" between 27" and 80" high
Rec. Solution: Remove object or provide detectable warning for the visually impaired
Findings:
Fire hose bib protrudes 16‐1/2" at 46" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 4 ‐ West Exit Stairway S4090
Barrier #: 99D
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Horn/Strobe ‐ Common Use Area
Barrier Description:
No horn/strobes in common use areas
Rec. Solution: Provide strobe in common use area
Findings:
No device provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $5,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702.1
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 6 of 8
ADA Assessment and Survey 2014 311
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ East Exit Stairway S5090
Barrier #: 100A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Tactile Exit Signs ‐ Stairway
Barrier Description:
Door leading directly into an exit stairway lacks tactile exit sign
Rec. Solution: Provide sign stating “EXIT STAIR DOWN (or UP)” at latch side of door
Findings:
Door to exit stair with low level illuminated sign lacks tactile exit sign
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ East Exit Stairway S5090
Barrier #: 100B
X Coordinate: N/A
Barrier Area: Stairways
Barrier Type: Sign ‐ Enclosed Exit Stairway (Ch 10)
Barrier Description:
Tactile stairway signage incorrectly indicates roof access, info for emergency personnel
Rec. Solution: Move existing sign and provide separate tactile stairway level sign at latch side of door
Findings:
Sign provided is misleading to the visually impaired
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
ICC A117.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 312
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ East Exit Stairway S5090
Barrier #: 100C
X Coordinate: N/A
Barrier Area: Clear Floor Space
Barrier Type: Protruding Object
Barrier Description:
Protruding object in circulation path protrudes more than 4" between 27" and 80" high
Rec. Solution: Remove object or provide detectable warning for the visually impaired
Findings:
Fire riser hose bib protrudes 16‐1/2" at 46" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ East Exit Stairway S5090
Barrier #: 100D
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Horn/Strobe ‐ Common Use Area
Barrier Description:
No horn/strobes in common use areas
Rec. Solution: Provide strobe in common use area
Findings:
No device provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $5,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702.1
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 313
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Central Hall H5000
Barrier #: 101A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Visual Information Provided (Exhibitions)
Barrier Description:
Visual sign providing information for program, service or activity not accessible
Rec. Solution: Provide information in alternate format to provide access to people with vision impairments
Findings:
Accessible sign not provided
Quantity: JOB
Notes: Artwork exhibited lacks description for the visually impaired
Barrier Severity: 1 Necessary Cost Est $5,000.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
ADA Title II Technical Assistance Manual 3.2000 Denial of participation
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Central Hall H5000
Barrier #: 101B
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Lobby Info Sign
Barrier Description:
No lobby informational sign with location of accessible elements
Rec. Solution: Provide lobby informational sign
Findings:
Accessible sign not provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 314
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Central Hall H5000
Barrier #: 101C
X Coordinate: N/A
Barrier Area: Corridors
Barrier Type: Lockers ‐ Ratio
Barrier Description:
No accessible locker provided
Rec. Solution: Provide at least 4 accessible lockers
Findings:
64 lockers and none are accessible
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $1,800.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 803
As‐built : 4
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Central Hall H5000
Barrier #: 101D
X Coordinate: N/A
Barrier Area: Counters and Tables
Barrier Type: Counter ‐ Surface Height
Barrier Description:
No section at least 3 feet long between 28" and 34" provided at existing counter
Rec. Solution: Provide min. 1 dictionary stand
Findings:
Dictionary stand surface 42" ‐ 48" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $875.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 902.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 315
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Central Hall H5000
Barrier #: 101E
X Coordinate: N/A
Barrier Area: Corridors
Barrier Type: Strobe Height ‐ 80" on Wall
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobes
Findings:
Strobes mounted 77‐1/2" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $2,200.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 4
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Library Catalogue Center 5062
Barrier #: 102A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Permanent Room/Space ‐ Tactile Characters
Barrier Description:
No tactile characters at sign identifying permanent rooms and spaces with visual signs
Rec. Solution: Provide accessible sign
Findings:
No tactile signage provided at door within public route
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 216.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 316
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Library Catalogue Center 5062
Barrier #: 102B
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Electrical Outlets ‐ Side Reach Obstructed (10"‐24")
Barrier Description:
Outlet located over an 10" to 24" obstruction max. 34" high located above 46"
Rec. Solution: Relocate control or mechanism to max. 46" high
Findings:
Accessible carrel lacks accessible outlets and power strip below desk surface hanging along back wall
Quantity: EACH
Notes: Accessible knee clearance at desk
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Library Catalogue Center 5062
Barrier #: 102C
X Coordinate: N/A
Barrier Area: Counters and Tables
Barrier Type: Counter ‐ Surface Height
Barrier Description:
No section at least 3 feet long between 28" and 34" provided at existing counter
Rec. Solution: Provide accessible counter at scanner
Findings:
Scanner counter 38" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $875.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 902.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 317
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Library Catalogue Center 5062
Barrier #: 102D
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Actuator/Control ‐ Side Reach Obstructed (10"‐24")
Barrier Description:
Control or mechanism over an 10" to 24" obstruction max. 34" high located above 46"
Rec. Solution: Provide min. 1 accessible scanner
Findings:
Scanner controls and screen over an obstruction 38" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Library Catalogue Center 5062
Barrier #: 102E
X Coordinate: N/A
Barrier Area: Counters and Tables
Barrier Type: Counter ‐ Surface Height
Barrier Description:
No section at least 3 feet long between 28" and 34" provided at existing counter
Rec. Solution: Provide min. 3 ft long section of counter at max. 34" high
Findings:
Work counter 38" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $875.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 902.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 318
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Library Catalogue Center 5062
Barrier #: 102F
X Coordinate: N/A
Barrier Area: Counters and Tables
Barrier Type: Counter ‐ Knee Clearance
Barrier Description:
Knee clearance not min. 27" high, 19" deep or 30" wide
Rec. Solution: Provide min. 3 ft long section of counter at max. 34" high
Findings:
No knee clearance
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 0
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Northeast Stacks and Reading Balcony
Barrier #: 103A
X Coordinate: N/A
Barrier Area: Clear Floor Space
Barrier Type: Passageway ‐ Min. 36"
Barrier Description:
Circulation route not min. 36" wide between elements
Rec. Solution: Rearrange furniture/equipment to provide wheelchair access
Findings:
36" wide circulation route between double sided stacks in multiple locations
Quantity: LF
Notes: Study carrels and desks are accessible
Barrier Severity: 1 Necessary Cost Est $2,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 403.5.1
As‐built : 20
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 319
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Northeast Stacks and Reading Balcony
Barrier #: 103B
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobes
Findings:
Strobes mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $3,300.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 6
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Special Collections Lobby L5061
Barrier #: 104A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61" ‐ 62" high at rooms 5063 and 5065
Quantity: EACH
Notes: Also, braille not 3/8" and max. 1/2" directly below the tactile characters, braille on signs not located directly below tactile characters and braille dots on signs not domed or rounded
Barrier Severity: 1 Necessary Cost Est $500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 2
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 320
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Special Collections Lobby L5061
Barrier #: 104B
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Permanent Room/Space ‐ Tactile Characters
Barrier Description:
No tactile characters at sign identifying permanent rooms and spaces with visual signs
Rec. Solution: Provide accessible sign
Findings:
No tactile signage provided at door within public route
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 216.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Special Collections administration 5067
Barrier #: 105A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Tactile Exit Signs ‐ Passage
Barrier Description:
Exit thru an exit enclosure/exit passageway lacks tactile exit sign
Rec. Solution: Provide signs stating “EXIT ROUTE” at exit side of door
Findings:
Passageway to exterior exit with low level illuminated sign lacks tactile exit sign
Quantity: EACH
Notes: Need photo. No tactile exit signs at bit sets of double doors
Barrier Severity: 2 Recommended Cost Est $500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 2
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 321
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Special Collections administration 5067
Barrier #: 105B
X Coordinate: N/A
Barrier Area: Corridors
Barrier Type: Bench Back Support
Barrier Description:
No back support provided for bench
Rec. Solution: Provide min. one accessible bench in corridor
Findings:
Bench not accessible
Quantity: EACH
Notes: 2 benches
Barrier Severity: 3 Hindrance Cost Est $1,100.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 903.4
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Special Collections administration 5067
Barrier #: 105C
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Visual Information Provided (Exhibitions)
Barrier Description:
Visual sign providing information for program, service or activity not accessible
Rec. Solution: Provide information in alternate format to provide access to people with vision impairments
Findings:
Accessible sign not provided
Quantity: JOB
Notes: Exhibit lacks information for visually impaired
Barrier Severity: 1 Necessary Cost Est $5,000.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
ADA Title II Technical Assistance Manual 3.2000 Denial of participation
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 322
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Special Collections Reading Room 5069
Barrier #: 106A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Permanent Room/Space ‐ Tactile Characters
Barrier Description:
No tactile characters at sign identifying permanent rooms and spaces with visual signs
Rec. Solution: Provide accessible sign
Findings:
No tactile signage provided at door within public route
Quantity: EACH
Notes: No tactile signage provided at door within public route
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 216.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Special Collections Reading Room 5069
Barrier #: 106B
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61" high at rooms 5057 and 5059
Quantity: EACH
Notes: Also, braille not 3/8" and max. 1/2" directly below the tactile characters, braille on signs not located directly below tactile characters and braille dots on signs not domed or rounded
Barrier Severity: 1 Necessary Cost Est $500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 2
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 323
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Special Collections Reading Room 5069
Barrier #: 106C
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Tactile Exit Signs ‐ Passage
Barrier Description:
Exit thru an exit enclosure/exit passageway lacks tactile exit sign
Rec. Solution: Provide sign stating “EXIT ROUTE” at exit side of door
Findings:
Passageway to exterior exit with low level illuminated sign lacks tactile exit sign
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Special Collections Reading Room 5069
Barrier #: 106D
X Coordinate: N/A
Barrier Area: Counters and Tables
Barrier Type: Counter ‐ Surface Height
Barrier Description:
No section at least 3 feet long between 28" and 34" provided at existing counter
Rec. Solution: Provide min. 3 ft long section of counter at max. 34" high
Findings:
40‐1/2" high at service counter
Quantity: EACH
Notes: Tables, study counter, ORC scanner and study carrels are all accessible
Barrier Severity: 3 Hindrance Cost Est $875.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 902.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 324
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Special Collections Reading Room 5069
Barrier #: 106E
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Special Collections Coat Check Rm 5077
Barrier #: 107A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Tactile Exit Signs ‐ Passage
Barrier Description:
Exit thru an exit enclosure/exit passageway lacks tactile exit sign
Rec. Solution: Provide sign stating “EXIT ROUTE” at exit side of door
Findings:
Passageway to exterior exit with low level illuminated sign lacks tactile exit sign
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 325
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Special Collections Coat Check Rm 5077
Barrier #: 107B
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Lockers ‐ Ratio
Barrier Description:
No accessible locker provided in locker room
Rec. Solution: Provide min. 1 accessible locker or 5% overall
Findings:
8 lockers and none are accessible
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $450.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 803
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Special Collections Coat Check Rm 5077
Barrier #: 107C
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Coat Hook ‐ Height
Barrier Description:
Clothing hooks not max. 48" high AFF
Rec. Solution: Provide additional hook
Findings:
Coat rack 58" high
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $125.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 308.2
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 326
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Special Collections Coat Check Rm 5077
Barrier #: 107D
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Shelves or Cabinets
Barrier Description:
Shelf or cabinet not mounted max. 48" above floor or ground
Rec. Solution: Provide additional shelf at accessible height or provide assistance
Findings:
Shelf at 62" high
Quantity: JOB
Notes:
Barrier Severity: 3 Hindrance Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Group Learning Area 5180
Barrier #: 108A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Permanent Room/Space ‐ Tactile Characters
Barrier Description:
No tactile characters at sign identifying permanent rooms and spaces with visual signs
Rec. Solution: Provide accessible sign
Findings:
No tactile signage provided at door within public route
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 216.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 327
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Group Learning Area 5180
Barrier #: 108B
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61‐1/2" high at rooms 5771 and 5615. Approach to signs blocked by shelves
Quantity: EACH
Notes: Also, Braille not 3/8" and max. 1/2" directly below the tactile characters and Braille dots on signs not domed or rounded.
Barrier Severity: 1 Necessary Cost Est $500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 2
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Group Learning Area 5180
Barrier #: 108C
X Coordinate: N/A
Barrier Area: Clear Floor Space
Barrier Type: Clear Floor Space ‐ 60" Turning Circle
Barrier Description:
Clear floor space of min. 60" in diameter not provided where 360 degree turn is made
Rec. Solution: Rearrange furniture/equipment to provide wheelchair access
Findings:
38‐5/8" turning space at ends in multiple locations of stacks
Quantity: SF
Notes:
Barrier Severity: 2 Recommended Cost Est $3,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 304.3.1
As‐built : 20
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 328
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Group Learning Area 5180
Barrier #: 108D
X Coordinate: N/A
Barrier Area: Clear Floor Space
Barrier Type: Passageway ‐ Min. 36"
Barrier Description:
Circulation route not min. 36" wide between elements
Rec. Solution: Rearrange furniture/equipment to provide wheelchair access
Findings:
36" wide circulation route in multiple locations
Quantity: LF
Notes:
Barrier Severity: 1 Necessary Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 403.5.1
As‐built : 0
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Group Learning Area 5180
Barrier #: 108E
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobes
Findings:
Strobes mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $3,300.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 6
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 329
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Elevator/Restroom Corridor H5500
Barrier #: 109A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Permanent Room/Space ‐ Tactile Characters
Barrier Description:
No tactile characters at sign identifying permanent rooms and spaces with visual signs
Rec. Solution: Provide accessible signs
Findings:
Overhead visual sign info not provided in tactile signage at doorway within public route
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 216.2
As‐built : 2
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Elevator/Restroom Corridor H5500
Barrier #: 109B
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61" high at room 5567
Quantity: EACH
Notes: Also, Braille not 3/8" and max. 1/2" directly below the tactile characters and Braille dots on sign not domed or rounded
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 330
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Elevator/Restroom Corridor H5500
Barrier #: 109C
X Coordinate: N/A
Barrier Area: Drinking Fountains
Barrier Type: Alcove ‐ New Construction
Barrier Description:
Fountain with a leading edge between 27" and 80" high protrudes more than 4" into the circulation path.
Rec. Solution: Demolish and construct new alcove as detectable warning
Findings:
Hi‐Low drinking fountain not completely inside alcove
Quantity: SF
Notes:
Barrier Severity: 1 Necessary Cost Est $2,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307.2
As‐built : 10
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Elevator/Restroom Corridor H5500
Barrier #: 109D
X Coordinate: N/A
Barrier Area: Drinking Fountains
Barrier Type: Operation ‐ Replacement
Barrier Description:
Operating mechanism involves more than 5 lbf to operate
Rec. Solution: Replace drinking fountain with accessible unit
Findings:
Needed more than 5 lbf where fountain is not adjustable
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 602.3
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 331
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Elevator/Restroom Corridor H5500
Barrier #: 109E
X Coordinate: N/A
Barrier Area: Corridors
Barrier Type: Strobe Height ‐ 80" on Wall
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Men's Restroom 5569
Barrier #: 110A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
62" high
Quantity: EACH
Notes: Also, Braille not 3/8" and max. 1/2" directly below the tactile characters and Braille dots on sign not domed or rounded. Pictograms not raised
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 332
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Men's Restroom 5569
Barrier #: 110B
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Interior
Barrier Description:
Door opening force exceeds 5 lbf
Rec. Solution: Provide automatic door opening device
Findings:
15 lbf
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $5,000.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.9
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Men's Restroom 5569
Barrier #: 110C
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Sweep Period
Barrier Description:
Door closer lacks min. 5 second sweep period
Rec. Solution: Provide automatic door opening device
Findings:
2 second sweep
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.8.1
As‐built : 0
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 333
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Men's Restroom 5569
Barrier #: 110D
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Dispensers ‐ Protruding Object
Barrier Description:
Protruding dispenser creates protruding hazard in path of travel
Rec. Solution: Remove dispenser or provide detectable warning for the visually impaired
Findings:
Paper towel dispensers protrude 10" at 44" high in path of travel to lavatory
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307.2
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Men's Restroom 5569
Barrier #: 110E
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Lavatory ‐ Rim Height
Barrier Description:
Lavatory rim or counter edge is higher than 34" AFF
Rec. Solution: Provide min. 1 accessible lavatory
Findings:
35" high AFF
Quantity: JOB
Notes:
Barrier Severity: 1 Necessary Cost Est $450.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 606.3
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 334
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Men's Restroom 5569
Barrier #: 110F
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Lavatory ‐ Knee Clearance
Barrier Description:
Lavatory bottom apron/edge not max 29" reducing to 27" at 8" back from edge
Rec. Solution: Remove cover at drainpipes
Findings:
7" deep knee clearance
Quantity: JOB
Notes:
Barrier Severity: 1 Necessary Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 606.2 & 306
As‐built : 0
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Men's Restroom 5569
Barrier #: 110G
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Electrical Outlets ‐ Side Reach Obstructed (10"‐24")
Barrier Description:
Outlet located over an 10" to 24" obstruction max. 34" high located above 46"
Rec. Solution: Relocate control or mechanism to max. 46" high
Findings:
44" high and 20" deep over an obstruction 34‐1/4" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 335
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Men's Restroom 5569
Barrier #: 110H
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Stall Door Closer
Barrier Description:
Stall door not equipped with an automatic closing device
Rec. Solution: Replace compartment hinge with adjustible mechanism
Findings:
Stall door not self‐closing
Quantity: JOB
Notes:
Barrier Severity: 2 Recommended Cost Est $1,650.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.8.1.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Men's Restroom 5569
Barrier #: 110I
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Stall ‐ Door Hardware
Barrier Description:
Outside of compartment door lacks a loop or U‐pull below latch
Rec. Solution: Provide hardware
Findings:
No U‐pull provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $75.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.8.1.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 336
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Men's Restroom 5569
Barrier #: 110J
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Stall ‐ Door Hardware
Barrier Description:
Inside of compartment door lacks a loop or U‐pull below latch
Rec. Solution: Provide hardware
Findings:
No U‐pull provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $75.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.8.1.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Men's Restroom 5569
Barrier #: 110K
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Coat Hook
Barrier Description:
Clothing hooks not max. 48" high AFF
Rec. Solution: Provide additional hook in new location
Findings:
Coat hook inside stall 58" high
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $125.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.3
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 337
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Men's Restroom 5569
Barrier #: 110L
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Paper Dispenser
Barrier Description:
Toilet tissue dispenser not within 7" to 9" from front edge of toilet
Rec. Solution: Reposition or replace toilet paper dispenser
Findings:
14" from front edge of toilet
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $225.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.7
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Men's Restroom 5569
Barrier #: 110M
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Seat Cover Dispenser
Barrier Description:
Seat cover dispenser not located on an accessible route. Blocked by water closet
Rec. Solution: Replace or remount dispenser on an accessible route with clear floor space
Findings:
Access to dispenser blocked by water closet
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $125.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 338
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Men's Restroom 5569
Barrier #: 110N
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Family/Assisted Restroom 5565
Barrier #: 111A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61" high
Quantity: EACH
Notes: Also, Braille not 3/8" and max. 1/2" directly below the tactile characters and Braille dots on sign not domed or rounded. Pictograms not raised
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 339
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Family/Assisted Restroom 5565
Barrier #: 111B
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Automatic Doors ‐ Sign
Barrier Description:
ISA symbol at automatic door opening device not min. 4" x 4" in size
Rec. Solution: Recommended: Provide ISA symbol min. 4" x 4" in size
Findings:
Existing symbol 1‐3/4" high. Nor visible from a distance
Quantity: JOB
Notes:
Barrier Severity: 1 Necessary Cost Est $500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 2
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Family/Assisted Restroom 5565
Barrier #: 111C
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Automatic Doors ‐ BHMA Sign
Barrier Description:
Swinging/sliding/folding door lacks sign visible from both sides reading, "AUTOMATIC DOOR"
Rec. Solution: Provide new signs showing on both approaches to door
Findings:
No BHMA signs on either side of door
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 2
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 340
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Family/Assisted Restroom 5565
Barrier #: 111D
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Dispensers ‐ Protruding Object
Barrier Description:
Protruding dispenser creates protruding hazard in path of travel
Rec. Solution: Remove dispensers or provide detectable warning for the visually impaired
Findings:
Feminine product dispensers protrude 6" at 42" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $1,100.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307.2
As‐built : 2
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Family/Assisted Restroom 5565
Barrier #: 111E
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Dispensers ‐ Protruding Object
Barrier Description:
Protruding dispenser creates protruding hazard in path of travel
Rec. Solution: Remove dispenser or provide detectable warning for the visually impaired
Findings:
Paper towel dispenser protrudes 10" at 42" high in path of travel to lavatory
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307.2
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 341
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Family/Assisted Restroom 5565
Barrier #: 111F
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Lavatory ‐ Rim Height
Barrier Description:
Lavatory rim or counter edge is higher than 34" AFF
Rec. Solution: Provide min. 1 accessible lavatory
Findings:
34‐1/2" high AFF
Quantity: JOB
Notes:
Barrier Severity: 1 Necessary Cost Est $450.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 606.3
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Family/Assisted Restroom 5565
Barrier #: 111G
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Lavatory ‐ Knee Clearance
Barrier Description:
Lavatory bottom apron/edge not max 29" reducing to 27" at 8" back from edge
Rec. Solution: Remove cover on drainpipes
Findings:
6" deep knee clearance
Quantity: JOB
Notes:
Barrier Severity: 1 Necessary Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 606.2 & 306
As‐built : 0
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 342
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Family/Assisted Restroom 5565
Barrier #: 111H
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Electrical Outlets ‐ Side Reach Obstructed (10"‐24")
Barrier Description:
Outlet located over an 10" to 24" obstruction max. 34" high located above 46"
Rec. Solution: Relocate control or mechanism to max. 46" high
Findings:
Electrical outlets behind dispensers and cannot be used
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Family/Assisted Restroom 5565
Barrier #: 111I
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Transfer ‐ Floor‐mounted
Barrier Description:
Min. 60" wide x 59" deep clear floor space not provided at floor‐mounted fixture
Rec. Solution: Remodel to provide front transfer space
Findings:
56" wide between wall and lavatory
Quantity: SF
Notes:
Barrier Severity: 2 Recommended Cost Est $57,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.8.1.1
As‐built : 100
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 343
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Family/Assisted Restroom 5565
Barrier #: 111J
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Centerline
Barrier Description:
Water closet centerline not between 16" and 18" O. C.
Rec. Solution: Relocate water closet
Findings:
18‐1/2" on center
Quantity: JOB
Notes:
Barrier Severity: 3 Hindrance Cost Est $850.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Family/Assisted Restroom 5565
Barrier #: 111K
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Paper Dispenser
Barrier Description:
Toilet tissue dispenser not within 7" to 9" from front edge of toilet
Rec. Solution: Reposition or replace toilet paper dispenser
Findings:
14" from front edge of toilet
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $225.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.7
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 344
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Family/Assisted Restroom 5565
Barrier #: 111L
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Seat Cover Dispenser
Barrier Description:
Seat cover dispenser not located on an accessible route. Blocked by water closet
Rec. Solution: Replace or remount dispenser on an accessible route with clear floor space
Findings:
Access to dispenser blocked by water closet
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $125.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Family/Assisted Restroom 5565
Barrier #: 111M
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 345
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Women's Restroom 5566
Barrier #: 112A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
62" high
Quantity: EACH
Notes: Also, Braille not 3/8" and max. 1/2" directly below the tactile characters and Braille on sign not domed or rounded
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Women's Restroom 5566
Barrier #: 112B
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Interior
Barrier Description:
Door opening force exceeds 5 lbf
Rec. Solution: Provide automatic door opening device
Findings:
18 lbf
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $5,000.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.9
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 346
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Women's Restroom 5566
Barrier #: 112C
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Sweep Period
Barrier Description:
Door closer lacks min. 5 second sweep period
Rec. Solution: Provide automatic door opening device
Findings:
2 second sweep
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.8.1
As‐built : 0
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Women's Restroom 5566
Barrier #: 112D
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Dispensers ‐ Protruding Object
Barrier Description:
Protruding dispenser creates protruding hazard in path of travel
Rec. Solution: Remove dispensers or provide detectable warning for the visually impaired
Findings:
Feminine product dispensers protrude 6" at 42" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $1,100.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307.2
As‐built : 2
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 347
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Women's Restroom 5566
Barrier #: 112E
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Dispensers ‐ Sanitary Products
Barrier Description:
Feminine product dispenser does not operate at 5 lbf or less
Rec. Solution: Replace dispensers
Findings:
Exceed 5 lbf
Quantity: EACH
Notes: 2 of 2 feminine product dispensers
Barrier Severity: 1 Necessary Cost Est $650.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 603.3
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Women's Restroom 5566
Barrier #: 112F
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Lavatory ‐ Rim Height
Barrier Description:
Lavatory rim or counter edge is higher than 34" AFF
Rec. Solution: Provide min. 1 accessible lavatory
Findings:
35" high AFF
Quantity: JOB
Notes:
Barrier Severity: 1 Necessary Cost Est $450.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 606.3
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 348
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Women's Restroom 5566
Barrier #: 112G
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Lavatory ‐ Knee Clearance
Barrier Description:
Lavatory bottom apron/edge not max 29" reducing to 27" at 8" back from edge
Rec. Solution: Remove cover over drainpipes
Findings:
6‐1/2" deep knee clearance
Quantity: JOB
Notes:
Barrier Severity: 1 Necessary Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 606.2 & 306
As‐built : 0
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Women's Restroom 5566
Barrier #: 112H
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Electrical Outlets ‐ Side Reach Obstructed (10"‐24")
Barrier Description:
Outlet located over an 10" to 24" obstruction max. 34" high located above 46"
Rec. Solution: Relocate control or mechanism to max. 46" high
Findings:
44" high and 22" deep over an obstruction 34‐1/4" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 349
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Women's Restroom 5566
Barrier #: 112I
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Stall Door Closer
Barrier Description:
Stall door not equipped with an automatic closing device
Rec. Solution: Replace compartment hinge with adjustible mechanism
Findings:
Stall door not self‐closing
Quantity: JOB
Notes:
Barrier Severity: 2 Recommended Cost Est $1,650.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.8.1.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Women's Restroom 5566
Barrier #: 112J
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Stall ‐ Door Hardware
Barrier Description:
Inside of compartment door lacks a loop or U‐pull below latch
Rec. Solution: Provide hardware
Findings:
No U‐pull provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $75.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.8.1.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 350
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Women's Restroom 5566
Barrier #: 112K
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Paper Dispenser
Barrier Description:
Toilet tissue dispenser not within 7" to 9" from front edge of toilet
Rec. Solution: Reposition or replace toilet paper dispenser
Findings:
14" from front edge of toilet
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $225.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.7
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Women's Restroom 5566
Barrier #: 112L
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Seat Cover Dispenser
Barrier Description:
Seat cover dispenser not located on an accessible route. Blocked by water closet
Rec. Solution: Replace or remount dispenser on an accessible route with clear floor space
Findings:
Access to dispenser blocked by water closet
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $125.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 351
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Women's Restroom 5566
Barrier #: 112M
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ East Emergency Exit Stairway S5790
Barrier #: 113A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61‐1/2" high. Existing sign states "STAIR"
Quantity: EACH
Notes: Also, braille dots on sign not domed or rounded
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 352
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ East Emergency Exit Stairway S5790
Barrier #: 113B
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Tactile Exit Signs ‐ Stairway
Barrier Description:
Door leading directly into an exit stairway lacks tactile exit sign
Rec. Solution: Provide sign stating “EXIT STAIR DOWN (or UP)” at latch side of door
Findings:
No tactile exit sign for stair. Existing sign states "STAIR"
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ East Emergency Exit Stairway S5790
Barrier #: 113C
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Interior Adjustment
Barrier Description:
Door opening force exceeds 5 lbf
Rec. Solution: Replace or adjust existing closer. Door does not lead to an accessible route
Findings:
14 lbf at door to corridor
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $450.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.9
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 353
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ East Emergency Exit Stairway S5790
Barrier #: 113D
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Sweep Period
Barrier Description:
Door closer lacks min. 5 second sweep period
Rec. Solution: Replace or adjust existing closer. Door does not lead to an accessible route
Findings:
2 second sweep at door to corridor
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.8.1
As‐built : 0
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ East Emergency Exit Stairway S5790
Barrier #: 113E
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Recessed Door ‐ Push Side
Barrier Description:
Door recessed by more than 8" lacks at least 12" clearance at push side of door
Rec. Solution: No remediation recommended. Door does not lead to an accessible route
Findings:
No strike edge clearance and recess 10‐1/4"
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.4.3
As‐built : 0
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 354
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ East Emergency Exit Stairway S5790
Barrier #: 113F
X Coordinate: N/A
Barrier Area: Stairways
Barrier Type: Sign ‐ Enclosed Exit Stairway (Ch 10)
Barrier Description:
Tactile stairway signage incorrectly indicates roof access, info for emergency personnel
Rec. Solution: Move existing sign and provide separate tactile stairway level sign at latch side of door
Findings:
Sign provided is misleading to the visually impaired
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
ICC A117.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ East Emergency Exit Stairway S5790
Barrier #: 113G
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Horn/Strobe ‐ Common Use Area
Barrier Description:
No horn/strobes in common use areas
Rec. Solution: Provide strobe in common use area
Findings:
No device provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $5,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702.1
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 355
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Norman & Glenville Starr Wilson Room 5759
Barrier #: 114A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61‐1/2" high
Quantity: EACH
Notes: Also, Braille not 3/8" and max. 1/2" directly below the tactile characters and Braille dots on sign not domed or rounded. This is a museum containing antique furniture and artwork
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Norman & Glenville Starr Wilson Room 5759
Barrier #: 114B
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Threshold ‐ Height exceeding 1/2"
Barrier Description:
Door/Gate threshold exceeds 1/2" in height
Rec. Solution: Provide new door threshold
Findings:
3/4" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $275.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.5
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 356
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Norman & Glenville Starr Wilson Room 5759
Barrier #: 114C
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Electrical Switches ‐ Height
Barrier Description:
Light switch control box top edge not at max. 48" high
Rec. Solution: Relocate switch box top edge to max. 48" high
Findings:
49" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 308.2
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Norman & Glenville Starr Wilson Room 5759
Barrier #: 114D
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Visual Information Provided (Exhibitions)
Barrier Description:
Visual sign providing information for program, service or activity not accessible
Rec. Solution: Provide information in alternate format to provide access to people with vision impairments
Findings:
No information on exhibits for visually impaired
Quantity: JOB
Notes:
Barrier Severity: 1 Necessary Cost Est $5,000.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
ADA Title II Technical Assistance Manual 3.2000 Denial of participation
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 357
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Norman & Glenville Starr Wilson Room 5759
Barrier #: 114E
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ West Emergency Exit Stairway S5710
Barrier #: 115A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61‐1/2" high
Quantity: EACH
Notes: Existing sign states "STAIR". Also, braille dots on sign not domed or rounded
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 358
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ West Emergency Exit Stairway S5710
Barrier #: 115B
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Tactile Exit Signs ‐ Stairway
Barrier Description:
Door leading directly into an exit stairway lacks tactile exit sign
Rec. Solution: Provide sign stating “EXIT STAIR DOWN (or UP)” at latch side of door
Findings:
Door to exit stair with low level illuminated sign lacks tactile exit sign
Quantity: EACH
Notes: No tactile exit sign for stair. Existing sign states "STAIR"
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ West Emergency Exit Stairway S5710
Barrier #: 115C
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Interior Adjustment
Barrier Description:
Door opening force exceeds 5 lbf
Rec. Solution: Replace or adjust existing closer. Door does not lead to an accessible route
Findings:
14 lbf
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $450.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.9
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 359
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ West Emergency Exit Stairway S5710
Barrier #: 115D
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Interior Sweep Period
Barrier Description:
Door closer lacks min. 5 second sweep period or does not stop 5" from door frame
Rec. Solution: Replace or adjust existing closer. Door does not lead to an accessible route
Findings:
2 second sweep
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.8.1
As‐built : 0
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ West Emergency Exit Stairway S5710
Barrier #: 115E
X Coordinate: N/A
Barrier Area: Stairways
Barrier Type: Sign ‐ Enclosed Exit Stairway (Ch 10)
Barrier Description:
Tactile stairway signage incorrectly indicates roof access, info for emergency personnel
Rec. Solution: Move existing sign and provide separate tactile stairway level sign at latch side of door
Findings:
Sign provided is misleading to the visually impaired
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
ICC A117.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 360
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ West Emergency Exit Stairway S5710
Barrier #: 115F
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Horn/Strobe ‐ Common Use Area
Barrier Description:
No horn/strobes in common use areas
Rec. Solution: Provide strobe in common use area
Findings:
No device provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $5,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702.1
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Exit Lobby L5711
Barrier #: 116A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61" high at entry door
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 361
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Exit Lobby L5711
Barrier #: 116B
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Interior
Barrier Description:
Door opening force exceeds 5 lbf
Rec. Solution: Provide automatic door opening device
Findings:
18 lbf at door to elevator
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $5,000.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.9
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Exit Lobby L5711
Barrier #: 116C
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Sweep Period
Barrier Description:
Door closer lacks min. 5 second sweep period
Rec. Solution: Provide automatic door opening device
Findings:
3 second sweep at door to elevator
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.8.1
As‐built : 0
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 362
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Exit Lobby L5711
Barrier #: 116D
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Electrical Switches ‐ Height
Barrier Description:
Light switch control box top edge not at max. 48" high
Rec. Solution: Relocate switch box top edge to max. 48" high
Findings:
50" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 308.2
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Exit Lobby L5711
Barrier #: 116E
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 363
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Group Study Rooms
Barrier #: 117A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61‐1/2" high at Group Study Rooms 5559 ‐ 5564
Quantity: EACH
Notes: Also, Braille on signs not located directly below tactile characters and braille dots on sigs not domed or rounded. Room 5563 is designated as accessible study room
Barrier Severity: 1 Necessary Cost Est $1,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 6
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Group Study Rooms
Barrier #: 117B
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Electrical Switches ‐ Height
Barrier Description:
Light switch control box top edge not at max. 48" high
Rec. Solution: Relocate switch box top edge to max. 48" high
Findings:
50" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 308.2
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 364
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Group Study Rooms
Barrier #: 117C
X Coordinate: N/A
Barrier Area: Counters and Tables
Barrier Type: Table ‐ Pedestal Base
Barrier Description:
Knee clearance not min. 27" high, 19" deep or 30" wide
Rec. Solution: Provide min. 1 accessible table. Avoid pedestal base tables
Findings:
No knee clearance at pedestal table
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 306.2.2 and 306.2.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Group Study Rooms
Barrier #: 117D
X Coordinate: N/A
Barrier Area: Clear Floor Space
Barrier Type: Clear Floor Space ‐ 60" Turning Circle
Barrier Description:
Clear floor space of min. 60" in diameter not provided where 360 degree turn is made
Rec. Solution: Remove table to provide min. 60" turning space or remodel
Findings:
No maneuvering clearance and turning space between table and whiteboards
Quantity: SF
Notes:
Barrier Severity: 2 Recommended Cost Est $14,000.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 304.3.1
As‐built : 80
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 365
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Group Study Rooms
Barrier #: 117E
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Barnard Classroom 5420
Barrier #: 118A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61‐1/2" high
Quantity: EACH
Notes: Also, Braille on sign not located directly below tactile characters and braille dots on sign not domed or rounded
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 366
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Barnard Classroom 5420
Barrier #: 118B
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Electrical Switches ‐ Height
Barrier Description:
Light switch control box top edge not at max. 48" high
Rec. Solution: Relocate switch box top edge to max. 48" high
Findings:
50" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 308.2
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Barnard Classroom 5420
Barrier #: 118C
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Clear Width
Barrier Description:
Clear width passage through door, sliding/folding door or gate is not min. 32"
Rec. Solution: Move chairs to provide maneuvering clearance at doors
Findings:
24" ‐ 26" clear width at entry doors due to chairs stored in pathway
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.3
As‐built : 0
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 367
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Barnard Classroom 5420
Barrier #: 118D
X Coordinate: N/A
Barrier Area: Classrooms
Barrier Type: Workstation ‐ Knee Clearance
Barrier Description:
Knee clearance of at least 27" high, 30" wide and 8" deep not provided
Rec. Solution: Provide min. 1 accessible workstation or 5% overall
Findings:
26‐3/8" high knee clearance
Quantity: EACH
Notes: 15 Mac workstations and none are accessible
Barrier Severity: 1 Necessary Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 902
As‐built : 0
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Barnard Classroom 5420
Barrier #: 118E
X Coordinate: N/A
Barrier Area: Classrooms
Barrier Type: Podium ‐ Knee Clearance
Barrier Description:
Podium knee clearance not min. 27" high, 19" deep or 30" wide
Rec. Solution: Provide min. 1 accessible podium
Findings:
13‐1/2" deep knee clearance at base for adjustable podium
Quantity: SF
Notes:
Barrier Severity: 4 Low Severity Cost Est $1,275.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 504.2
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 368
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Barnard Classroom 5420
Barrier #: 118F
X Coordinate: N/A
Barrier Area: Classrooms
Barrier Type: Projector Screen Pull
Barrier Description:
Screen pull not at max. 48" high for side reach
Rec. Solution: Relocate to max. 48" high or provide extension
Findings:
Projector screen pull over 48" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $75.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Barnard Classroom 5420
Barrier #: 118G
X Coordinate: N/A
Barrier Area: Classrooms
Barrier Type: Alarm ‐ Strobe Mounting Height
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702.1
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 369
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Research Study Room Corridor H5100
Barrier #: 119A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61" high
Quantity: EACH
Notes: Also, Braille not 3/8" and max. 1/2" directly below the tactile characters and Braille on sign not domed or rounded
Barrier Severity: 1 Necessary Cost Est $3,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 14
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ Research Study Room Corridor H5100
Barrier #: 119B
X Coordinate: N/A
Barrier Area: Corridors
Barrier Type: Strobe Height ‐ 80" on Wall
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 370
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ West Exit Stairway S5010
Barrier #: 120A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Tactile Exit Signs ‐ Stairway
Barrier Description:
Door leading directly into an exit stairway lacks tactile exit sign
Rec. Solution: Provide sign stating “EXIT STAIR DOWN (or UP)” at latch side of door
Findings:
Door to exit stair with low level illuminated sign lacks tactile exit sign
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ West Exit Stairway S5010
Barrier #: 120B
X Coordinate: N/A
Barrier Area: Stairways
Barrier Type: Sign ‐ Enclosed Exit Stairway (Ch 10)
Barrier Description:
Tactile stairway signage incorrectly indicates roof access, info for emergency personnel
Rec. Solution: Move existing sign and provide separate tactile stairway level sign at latch side of door
Findings:
Sign provided is misleading to the visually impaired
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
ICC A117.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 371
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ West Exit Stairway S5010
Barrier #: 120C
X Coordinate: N/A
Barrier Area: Clear Floor Space
Barrier Type: Protruding Object
Barrier Description:
Protruding object in circulation path protrudes more than 4" between 27" and 80" high
Rec. Solution: Remove object or provide detectable warning for the visually impaired
Findings:
Fire riser hose bib protrudes 16‐1/2" at 46" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 5 ‐ West Exit Stairway S5010
Barrier #: 120D
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Horn/Strobe ‐ Common Use Area
Barrier Description:
No horn/strobes in common use areas
Rec. Solution: Provide strobe in common use area
Findings:
No device provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $5,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702.1
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 7 of 8
ADA Assessment and Survey 2014 372
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ West Exit Stairway S6010
Barrier #: 121A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Tactile Exit Signs ‐ Stairway
Barrier Description:
Door leading directly into an exit stairway lacks tactile exit sign
Rec. Solution: Provide sign stating “EXIT STAIR DOWN (or UP)” at latch side of door
Findings:
Door to exit stair with low level illuminated sign lacks tactile exit sign
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 8 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ West Exit Stairway S6010
Barrier #: 121B
X Coordinate: N/A
Barrier Area: Stairways
Barrier Type: Sign ‐ Enclosed Exit Stairway (Ch 10)
Barrier Description:
Tactile stairway signage incorrectly indicates roof access, info for emergency personnel
Rec. Solution: Move existing sign and provide separate tactile stairway level sign at latch side of door
Findings:
Sign provided is misleading to the visually impaired
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
ICC A117.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
ADA Assessment and Survey 2014 373
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ West Exit Stairway S6010
Barrier #: 121C
X Coordinate: N/A
Barrier Area: Clear Floor Space
Barrier Type: Protruding Object
Barrier Description:
Protruding object in circulation path protrudes more than 4" between 27" and 80" high
Rec. Solution: Remove object or provide detectable warning for the visually impaired
Findings:
Fire riser hose bib protrudes 16‐1/2" at 46" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ West Exit Stairway S6010
Barrier #: 121D
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Horn/Strobe ‐ Common Use Area
Barrier Description:
No horn/strobes in common use areas
Rec. Solution: Provide strobe in common use area
Findings:
No device provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $5,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702.1
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
ADA Assessment and Survey 2014 374
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Central Corridor H6000
Barrier #: 122A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61" high at room 6043 sign in elevator lobby
Quantity: EACH
Notes: Also, Braille not 3/8" and max. 1/2" directly below the tactile characters and Braille on sign not domed or rounded
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Central Corridor H6000
Barrier #: 122B
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Lobby Info Sign
Barrier Description:
No lobby informational sign with location of accessible elements
Rec. Solution: Provide lobby informational sign
Findings:
Accessible sign not provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 8 of 8
ADA Assessment and Survey 2014 375
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Central Corridor H6000
Barrier #: 122C
X Coordinate: N/A
Barrier Area: Corridors
Barrier Type: Lockers ‐ Ratio
Barrier Description:
No accessible locker provided
Rec. Solution: Provide at least 4 accessible lockers or 5% overall
Findings:
64 lockers and none are accessible
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $1,800.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 803
As‐built : 4
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Central Corridor H6000
Barrier #: 122D
X Coordinate: N/A
Barrier Area: Counters and Tables
Barrier Type: Counter ‐ Surface Height
Barrier Description:
No section at least 3 feet long between 28" and 34" provided at existing counter
Rec. Solution: Provide min. 1 dictionary stand
Findings:
Dictionary stand surface 42" ‐ 48" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $875.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 902.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
ADA Assessment and Survey 2014 376
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Central Corridor H6000
Barrier #: 122E
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Visual Information Provided (Exhibitions)
Barrier Description:
Visual sign providing information for program, service or activity not accessible
Rec. Solution: Provide information in alternate format to provide access to people with vision impairments
Findings:
Accessible sign not provided
Quantity: JOB
Notes: Artwork exhibited lacks description for the visually impaired
Barrier Severity: 1 Necessary Cost Est $5,000.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
ADA Title II Technical Assistance Manual 3.2000 Denial of participation
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Central Corridor H6000
Barrier #: 122F
X Coordinate: N/A
Barrier Area: Corridors
Barrier Type: Strobe Height ‐ 80" on Wall
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobes
Findings:
Strobes mounted 77‐1/2" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $2,200.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 4
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
ADA Assessment and Survey 2014 377
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Library Catalogue Center 6062
Barrier #: 123A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Permanent Room/Space ‐ Tactile Characters
Barrier Description:
No tactile characters at sign identifying permanent rooms and spaces with visual signs
Rec. Solution: Provide accessible sign
Findings:
Wall visual sIgn with no braille/tactile information at wall at entry point
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 216.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Library Catalogue Center 6062
Barrier #: 123B
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Electrical Outlets ‐ Side Reach Obstructed (10"‐24")
Barrier Description:
Outlet located over an 10" to 24" obstruction max. 34" high located above 46"
Rec. Solution: Relocate control or mechanism to max. 46" high
Findings:
Accessible carrel lacks accessible electrical outlets and power strip below desk surface hanging along back wall
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
ADA Assessment and Survey 2014 378
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Group Study Area
Barrier #: 124A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61" high
Quantity: EACH
Notes: Rooms 6012, 6022, 6084, 6615 and 6771. Also, signs not mounted at 18" from door swing, braille not 3/8" and max. 1/2" below the tactile characters, braille on signs not directly below tactile characters
Barrier Severity: 1 Necessary Cost Est $1,250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 5
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Group Study Area
Barrier #: 124B
X Coordinate: N/A
Barrier Area: Clear Floor Space
Barrier Type: Passageway ‐ Min. 36"
Barrier Description:
Circulation route not min. 36" wide between elements
Rec. Solution: Demolish existing and construct new passageway
Findings:
36" clear width between double sided stacks in multiple locations
Quantity: LF
Notes:
Barrier Severity: 1 Necessary Cost Est $125.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 403.5.1
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
ADA Assessment and Survey 2014 379
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Group Study Area
Barrier #: 124C
X Coordinate: N/A
Barrier Area: Clear Floor Space
Barrier Type: Clear Floor Space ‐ 60" Turning Circle
Barrier Description:
Clear floor space of min. 60" in diameter not provided where 360 degree turn is made
Rec. Solution: Remodel area to provide min. 60" turning space
Findings:
51‐1/2" turning space on ends between carrels and stacks
Quantity: SF
Notes:
Barrier Severity: 2 Recommended Cost Est $175.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 304.3.1
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Group Study Area
Barrier #: 124D
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobes
Findings:
Strobes mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $3,300.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 6
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
ADA Assessment and Survey 2014 380
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Large Group Study Room 6420
Barrier #: 125A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
62" high
Quantity: EACH
Notes: Also, braille not 3/8" and max. 1/2" directly below the tactile characters, braille on sign not located directly below tactile characters and braille dots on sign not domed or rounded. Accessible tables
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Large Group Study Room 6420
Barrier #: 125B
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Horn/Strobe ‐ Common Use Area
Barrier Description:
No horn/strobes in common use areas
Rec. Solution: Provide strobe in common use area
Findings:
No device provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $5,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702.1
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
ADA Assessment and Survey 2014 381
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ West Emergency Exit Stairway S6710
Barrier #: 126A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61‐1/2" high
Quantity: EACH
Notes: Also, braille dots on sign not domed or rounded
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ West Emergency Exit Stairway S6710
Barrier #: 126B
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Interior Adjustment
Barrier Description:
Door opening force exceeds 5 lbf
Rec. Solution: Replace or adjust existing closer. Door does not lead to an accessible route
Findings:
14 lbf
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $450.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.9
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
ADA Assessment and Survey 2014 382
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ West Emergency Exit Stairway S6710
Barrier #: 126C
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Sweep Period
Barrier Description:
Door closer lacks min. 5 second sweep period
Rec. Solution: Replace or adjust existing closer. Door does not lead to an accessible route
Findings:
2 second sweep
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.8.1
As‐built : 0
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ West Emergency Exit Stairway S6710
Barrier #: 126D
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Tactile Exit Signs ‐ Stairway
Barrier Description:
Door leading directly into an exit stairway lacks tactile exit sign
Rec. Solution: Provide sign stating “EXIT STAIR DOWN (or UP)” at latch side of door
Findings:
Door to exit stair with low level illuminated sign lacks tactile exit sign
Quantity: EACH
Notes: No tactile exit sign for stair. Existing sign states "STAIR"
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 8 of 8
ADA Assessment and Survey 2014 383
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ West Emergency Exit Stairway S6710
Barrier #: 126E
X Coordinate: N/A
Barrier Area: Stairways
Barrier Type: Sign ‐ Encl Stairway Level
Barrier Description:
Tactile stairway signage not provided to indicate floor level
Rec. Solution: Provide sign
Findings:
No stair level ID sign
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
ICC A117.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ West Emergency Exit Stairway S6710
Barrier #: 126F
X Coordinate: N/A
Barrier Area: Stairways
Barrier Type: Contrasting Color ‐ ADA
Barrier Description:
No contrasting color on each tread of interior stairway
Rec. Solution: Recommended: Consider providing contrasting color on each tread
Findings:
Treads lack contrasting color defined as 70% contrast
Quantity: LF or TR
Notes:
Barrier Severity: 2 Recommended Cost Est $35.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS Advisory 504.4
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 8 of 8
ADA Assessment and Survey 2014 384
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ West Emergency Exit Stairway S6710
Barrier #: 126G
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Horn/Strobe ‐ Common Use Area
Barrier Description:
No horn/strobes in common use areas
Rec. Solution: Provide strobe in common use area
Findings:
No device provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $5,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702.1
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Exit Lobby L6711
Barrier #: 127A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61" high
Quantity: EACH
Notes: Also, sign not mounted and centered at 18" from door swing
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
ADA Assessment and Survey 2014 385
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Exit Lobby L6711
Barrier #: 127B
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Interior
Barrier Description:
Door opening force exceeds 5 lbf
Rec. Solution: Provide automatic door opening device
Findings:
18 lbf
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $5,000.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.9
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Exit Lobby L6711
Barrier #: 127C
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Sweep Period
Barrier Description:
Door closer lacks min. 5 second sweep period
Rec. Solution: Provide automatic door opening device
Findings:
3 second sweep
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.8.1
As‐built : 0
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
ADA Assessment and Survey 2014 386
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Exit Lobby L6711
Barrier #: 127D
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Electrical Switches ‐ Height
Barrier Description:
Light switch control box top edge not at max. 48" high
Rec. Solution: Relocate switch box top edge to max. 48" high
Findings:
50" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 308.2
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Exit Lobby L6711
Barrier #: 127E
X Coordinate: N/A
Barrier Area: Elevators
Barrier Type: Hall Call Buttons ‐ 42" High
Barrier Description:
The centerline of the hall call buttons not max. 42" above the floor
Rec. Solution: Replace hall call buttons
Findings:
42‐1/2" high on center
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $3,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 407.2.1
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
ADA Assessment and Survey 2014 387
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Exit Lobby L6711
Barrier #: 127F
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Elevator/Restroom Corridor H6500
Barrier #: 128A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Permanent Room/Space ‐ Tactile Characters
Barrier Description:
No tactile characters at sign identifying permanent rooms and spaces with visual signs
Rec. Solution: Provide accessible signs
Findings:
No tactile signage provided at door within public route
Quantity: EACH
Notes: Overhead visual signs
Barrier Severity: 1 Necessary Cost Est $500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 216.2
As‐built : 2
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
ADA Assessment and Survey 2014 388
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Elevator/Restroom Corridor H6500
Barrier #: 128B
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61" high
Quantity: EACH
Notes: Room 6567. Also, braille not 3/8" and max. 1/2" directly below the tactile characters, braille on sign not located directly below tactile characters and braille dots on sign not domed or rounded
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Elevator/Restroom Corridor H6500
Barrier #: 128C
X Coordinate: N/A
Barrier Area: Drinking Fountains
Barrier Type: Alcove ‐ New Construction
Barrier Description:
Fountain with a leading edge between 27" and 80" high protrudes more than 4" into the circulation path.
Rec. Solution: Demolish and construct new alcove as detectable warning
Findings:
Hi‐Low drinking fountain not completely inside alcove
Quantity: SF
Notes:
Barrier Severity: 1 Necessary Cost Est $2,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307.2
As‐built : 10
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
ADA Assessment and Survey 2014 389
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Elevator/Restroom Corridor H6500
Barrier #: 128D
X Coordinate: N/A
Barrier Area: Drinking Fountains
Barrier Type: Operation ‐ Replacement
Barrier Description:
Operating mechanism involves more than 5 lbf to operate
Rec. Solution: Replace drinking fountain with accessible unit
Findings:
Needed more than 5 lbf where fountain is not adjustable
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 602.3
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Elevator/Restroom Corridor H6500
Barrier #: 128E
X Coordinate: N/A
Barrier Area: Drinking Fountains
Barrier Type: Knee Clearance
Barrier Description:
Knee clearance under fountain not min. 27" high
Rec. Solution: Replace drinking fountain with accessible unit or remount existing
Findings:
26" high knee clearance
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 306.3
As‐built : 0
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
ADA Assessment and Survey 2014 390
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Elevator/Restroom Corridor H6500
Barrier #: 128F
X Coordinate: N/A
Barrier Area: Corridors
Barrier Type: Strobe Height ‐ 80" on Wall
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Men's Restroom 6569
Barrier #: 129A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
62" high
Quantity: EACH
Notes: Also, braille not 3/8" and max. 1/2" directly below the tactile characters, braille on sign not located directly below tactile characters and braille dots on sign not domed or rounded
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
ADA Assessment and Survey 2014 391
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Men's Restroom 6569
Barrier #: 129B
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Interior
Barrier Description:
Door opening force exceeds 5 lbf
Rec. Solution: Provide automatic door opening device
Findings:
15 lbf
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $5,000.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.9
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Men's Restroom 6569
Barrier #: 129C
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Sweep Period
Barrier Description:
Door closer lacks min. 5 second sweep period
Rec. Solution: Provide automatic door opening device
Findings:
2 second sweep
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.8.1
As‐built : 0
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
ADA Assessment and Survey 2014 392
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Men's Restroom 6569
Barrier #: 129D
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Dispensers ‐ Protruding Object
Barrier Description:
Protruding dispenser creates protruding hazard in path of travel
Rec. Solution: Remove dispenser or provide detectable warning for the visually impaired
Findings:
Paper towel dispenser protrudes 10" at 44" high in path of travel to lavatory
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307.2
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Men's Restroom 6569
Barrier #: 129E
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Lavatory ‐ Rim Height
Barrier Description:
Lavatory rim or counter edge is higher than 34" AFF
Rec. Solution: Provide min. 1 accessible lavatory
Findings:
34‐3/4" high AFF
Quantity: JOB
Notes:
Barrier Severity: 1 Necessary Cost Est $450.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 606.3
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
ADA Assessment and Survey 2014 393
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Men's Restroom 6569
Barrier #: 129F
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Lavatory ‐ Knee Clearance
Barrier Description:
Lavatory bottom apron/edge not max 29" reducing to 27" at 8" back from edge
Rec. Solution: Provide min. 1 accessible lavatory
Findings:
7" deep knee clearance
Quantity: JOB
Notes:
Barrier Severity: 1 Necessary Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 606.2 & 306
As‐built : 0
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Men's Restroom 6569
Barrier #: 129G
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Electrical Outlets ‐ Side Reach Obstructed (10"‐24")
Barrier Description:
Outlet located over an 10" to 24" obstruction max. 34" high located above 46"
Rec. Solution: Relocate control or mechanism to max. 46" high
Findings:
44" high and 24" deep over an obstruction 34" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
ADA Assessment and Survey 2014 394
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Men's Restroom 6569
Barrier #: 129H
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Stall Door Closer
Barrier Description:
Stall door not equipped with an automatic closing device
Rec. Solution: Replace compartment hinge with adjustible mechanism
Findings:
Stall door not self‐closing
Quantity: JOB
Notes:
Barrier Severity: 2 Recommended Cost Est $1,650.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.8.1.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Men's Restroom 6569
Barrier #: 129I
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Stall ‐ Door Hardware
Barrier Description:
Outside of compartment door lacks a loop or U‐pull below latch
Rec. Solution: Provide hardware
Findings:
No U‐pull provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $75.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.8.1.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
ADA Assessment and Survey 2014 395
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Men's Restroom 6569
Barrier #: 129J
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Stall ‐ Door Hardware
Barrier Description:
Inside of compartment door lacks a loop or U‐pull below latch
Rec. Solution: Provide hardware
Findings:
No U‐pull provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $75.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.8.1.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Men's Restroom 6569
Barrier #: 129K
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Seat Cover Dispenser
Barrier Description:
Seat cover dispenser not located on an accessible route. Blocked by water closet
Rec. Solution: Replace or remount dispenser on an accessible route with clear floor space
Findings:
Access to dispenser blocked by water closet
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $125.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
ADA Assessment and Survey 2014 396
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Men's Restroom 6569
Barrier #: 129L
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Paper Dispenser
Barrier Description:
Toilet tissue dispenser not within 7" to 9" from front edge of toilet
Rec. Solution: Reposition or replace toilet paper dispenser
Findings:
12" from front edge of toilet
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $225.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.7
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Men's Restroom 6569
Barrier #: 129M
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
ADA Assessment and Survey 2014 397
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Women's Restroom 6566
Barrier #: 130A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
62" high
Quantity: EACH
Notes: Also, braille not 3/8" and max. 1/2" directly below the tactile characters, braille on sign not located directly below tactile characters and braille dots on sign not domed or rounded
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Women's Restroom 6566
Barrier #: 130B
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Interior
Barrier Description:
Door opening force exceeds 5 lbf
Rec. Solution: Provide automatic door opening device
Findings:
18 lbf
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $5,000.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.9
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
ADA Assessment and Survey 2014 398
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Women's Restroom 6566
Barrier #: 130C
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Sweep Period
Barrier Description:
Door closer lacks min. 5 second sweep period
Rec. Solution: Provide automatic door opening device
Findings:
2 second sweep
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.8.1
As‐built : 0
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Women's Restroom 6566
Barrier #: 130D
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Dispensers ‐ Protruding Object
Barrier Description:
Protruding dispenser creates protruding hazard in path of travel
Rec. Solution: Remove dispensers or provide detectable warning for the visually impaired
Findings:
Feminine product dispensers protrude 6" at 42" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $1,100.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307.2
As‐built : 2
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
ADA Assessment and Survey 2014 399
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Women's Restroom 6566
Barrier #: 130E
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Dispensers ‐ Sanitary Products
Barrier Description:
Feminine product dispenser does not operate at 5 lbf or less
Rec. Solution: Replace dispensers
Findings:
Exceed 5 lbf
Quantity: EACH
Notes: 2 of 2 feminine product dispensers
Barrier Severity: 1 Necessary Cost Est $650.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 603.3
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Women's Restroom 6566
Barrier #: 130F
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Lavatory ‐ Rim Height
Barrier Description:
Lavatory rim or counter edge is higher than 34" AFF
Rec. Solution: Provide min. 1 accessible lavatory
Findings:
34‐1/4" high AFF
Quantity: JOB
Notes:
Barrier Severity: 1 Necessary Cost Est $450.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 606.3
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
ADA Assessment and Survey 2014 400
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Women's Restroom 6566
Barrier #: 130G
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Lavatory ‐ Knee Clearance
Barrier Description:
Lavatory bottom apron/edge not max 29" reducing to 27" at 8" back from edge
Rec. Solution: Provide min. 1 accessible lavatory
Findings:
7" deep knee clearance
Quantity: JOB
Notes:
Barrier Severity: 1 Necessary Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 606.2 & 306
As‐built : 0
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Women's Restroom 6566
Barrier #: 130H
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Electrical Outlets ‐ Side Reach Obstructed (10"‐24")
Barrier Description:
Outlet located over an 10" to 24" obstruction max. 34" high located above 46"
Rec. Solution: Relocate control or mechanism to max. 46" high
Findings:
44" high and 22" deep over an obstruction 34‐1/4" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 305.3
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
ADA Assessment and Survey 2014 401
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Women's Restroom 6566
Barrier #: 130I
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Stall Door Closer
Barrier Description:
Stall door not equipped with an automatic closing device
Rec. Solution: Replace compartment hinge with adjustible mechanism
Findings:
Stall door not self‐closing
Quantity: JOB
Notes:
Barrier Severity: 2 Recommended Cost Est $1,650.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.8.1.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Women's Restroom 6566
Barrier #: 130J
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Stall ‐ Door Hardware
Barrier Description:
Outside of compartment door lacks a loop or U‐pull below latch
Rec. Solution: Provide hardware
Findings:
No U‐pull provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $75.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.8.1.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
ADA Assessment and Survey 2014 402
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Women's Restroom 6566
Barrier #: 130K
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Stall ‐ Door Hardware
Barrier Description:
Inside of compartment door lacks a loop or U‐pull below latch
Rec. Solution: Provide hardware
Findings:
No U‐pull provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $75.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.8.1.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Women's Restroom 6566
Barrier #: 130L
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Paper Dispenser
Barrier Description:
Toilet tissue dispenser not within 7" to 9" from front edge of toilet
Rec. Solution: Reposition or replace toilet paper dispenser
Findings:
14" from front edge of toilet
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $225.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.7
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
ADA Assessment and Survey 2014 403
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Women's Restroom 6566
Barrier #: 130M
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Seat Cover Dispenser
Barrier Description:
Seat cover dispenser not located on an accessible route. Blocked by water closet
Rec. Solution: Replace or remount dispenser on an accessible route with clear floor space
Findings:
Access to dispenser blocked by water closet
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $125.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Women's Restroom 6566
Barrier #: 130N
X Coordinate: N/A
Barrier Area: Restrooms
Barrier Type: Toilet Centerline
Barrier Description:
Water closet centerline not between 16" and 18" O. C.
Rec. Solution: Relocate water closet
Findings:
18‐3/4" on center
Quantity: JOB
Notes:
Barrier Severity: 3 Hindrance Cost Est $850.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 604.2
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
ADA Assessment and Survey 2014 404
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Women's Restroom 6566
Barrier #: 130O
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ East Emergency Exit Stairway S6790
Barrier #: 131A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61‐1/2" high
Quantity: EACH
Notes: Also, braille dots on sign not domed or rounded
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
ADA Assessment and Survey 2014 405
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ East Emergency Exit Stairway S6790
Barrier #: 131B
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Interior Adjustment
Barrier Description:
Door opening force exceeds 5 lbf
Rec. Solution: Replace or adjust existing closer. Door does not lead to an accessible route
Findings:
14 lbf at door to corridor
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $450.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.9
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ East Emergency Exit Stairway S6790
Barrier #: 131C
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Sweep Period
Barrier Description:
Door closer lacks min. 5 second sweep period
Rec. Solution: Replace or adjust existing closer. Door does not lead to an accessible route
Findings:
2 second sweep at door to corridor
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.8.1
As‐built : 0
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
ADA Assessment and Survey 2014 406
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ East Emergency Exit Stairway S6790
Barrier #: 131D
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Recessed Door ‐ Push Side
Barrier Description:
Door recessed by more than 8" lacks at least 12" clearance at push side of door
Rec. Solution: No remediation recommended. Door does not lead to an accessible route
Findings:
No strike edge clearance at recess 10‐1/4" at door to corridor (open air space)
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $2,250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.4.3
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ East Emergency Exit Stairway S6790
Barrier #: 131E
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Tactile Exit Signs ‐ Stairway
Barrier Description:
Door leading directly into an exit stairway lacks tactile exit sign
Rec. Solution: Provide sign stating “EXIT STAIR DOWN (or UP)” at latch side of door
Findings:
No tactile exit sign for stair. Existing sign states "STAIR"
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 8 of 8
ADA Assessment and Survey 2014 407
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ East Emergency Exit Stairway S6790
Barrier #: 131F
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Exterior Adjustment
Barrier Description:
Door opening force exceeds 8.5 lbf
Rec. Solution: Replace or adjust existing closer. Door does not lead to an accessible route
Findings:
18 lbf at door to stairway
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $450.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 8 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ East Emergency Exit Stairway S6790
Barrier #: 131G
X Coordinate: N/A
Barrier Area: Doors or Gates
Barrier Type: Door Closer ‐ Exterior Sweep Period
Barrier Description:
Door closer lacks min. 5 second sweep period
Rec. Solution: Replace or adjust existing closer. Door does not lead to an accessible route
Findings:
2 second sweep at door to stairway
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $0.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 404.2.8.1
As‐built : 0
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
ADA Assessment and Survey 2014 408
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ East Emergency Exit Stairway S6790
Barrier #: 131H
X Coordinate: N/A
Barrier Area: Stairways
Barrier Type: Sign ‐ Enclosed Exit Stairway (Ch 10)
Barrier Description:
Tactile stairway signage incorrectly indicates roof access, info for emergency personnel
Rec. Solution: Move existing sign and provide separate tactile stairway level sign at latch side of door
Findings:
Sign provided is misleading to the visually impaired
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
ICC A117.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ East Emergency Exit Stairway S6790
Barrier #: 131I
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Horn/Strobe ‐ Common Use Area
Barrier Description:
No horn/strobes in common use areas
Rec. Solution: Provide strobe in common use area
Findings:
No device provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $5,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702.1
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
ADA Assessment and Survey 2014 409
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Accessible Study Room 6832
Barrier #: 132A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61‐1/2" high
Quantity: EACH
Notes: Also, Braille not 3/8" and max. 1/2" directly below the tactile characters and braille dots on signs not domed or rounded
Barrier Severity: 1 Necessary Cost Est $4,000.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 16
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Accessible Study Room 6832
Barrier #: 132B
X Coordinate: N/A
Barrier Area: Controls and Mechanisms
Barrier Type: Electrical Switches ‐ Height
Barrier Description:
Light switch control box top edge not at max. 48" high
Rec. Solution: Relocate switch box top edge to max. 48" high
Findings:
50" high
Quantity: EACH
Notes:
Barrier Severity: 3 Hindrance Cost Est $750.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 308.2
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
ADA Assessment and Survey 2014 410
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Accessible Study Room 6832
Barrier #: 132C
X Coordinate: N/A
Barrier Area: Counters and Tables
Barrier Type: Table ‐ Pedestal Base
Barrier Description:
Knee clearance not min. 27" high, 19" deep or 30" wide
Rec. Solution: Provide min. 1 accessible table. Avoid pedestal base tables
Findings:
Pedestal base blocks knee clearance
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $450.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 306.2.2 and 306.2.3
As‐built : 1
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Accessible Study Room 6832
Barrier #: 132D
X Coordinate: N/A
Barrier Area: Clear Floor Space
Barrier Type: Clear Floor Space ‐ 60" Turning Circle
Barrier Description:
Clear floor space of min. 60" in diameter not provided where 360 degree turn is made
Rec. Solution: Remove table or emodel area to provide min. 60" turning space
Findings:
No maneuvering clearance in room between table and whiteboards to allow use
Quantity: SF
Notes:
Barrier Severity: 2 Recommended Cost Est $14,000.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 304.3.1
As‐built : 80
Facility Function: Public
Implementation Priority: 2
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
ADA Assessment and Survey 2014 411
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Accessible Study Room 6832
Barrier #: 132E
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Research Study Room Corridor H6100
Barrier #: 133A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61" high
Quantity: EACH
Notes: Also, Braille not 3/8" and max. 1/2" directly below the tactile characters and Braille on signs not domed or rounded
Barrier Severity: 1 Necessary Cost Est $3,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 14
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
ADA Assessment and Survey 2014 412
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Research Study Room Corridor H6100
Barrier #: 133B
X Coordinate: N/A
Barrier Area: Corridors
Barrier Type: Strobe Height ‐ 80" on Wall
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes: These rooms are used by staff/researchers but the corridor is within the public circulation route
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Reading Room 6081
Barrier #: 134A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Location ‐ 48" to 60" high
Barrier Description:
Braille/Tactile information on sign not mounted between 48" and 60" from ground
Rec. Solution: Provide accessible sign and mount at proper height
Findings:
61" high
Quantity: EACH
Notes: Also, Braille not 3/8" and max. 1/2" directly below the tactile characters and Braille on sign not domed or rounded
Barrier Severity: 1 Necessary Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 703.4.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
ADA Assessment and Survey 2014 413
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Reading Room 6081
Barrier #: 134B
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Tactile Exit Signs ‐ Passage
Barrier Description:
Exit thru an exit enclosure/exit passageway lacks tactile exit sign
Rec. Solution: Provide sign stating “EXIT ROUTE” at exit side of door
Findings:
Passageway to exterior exit with low level illuminated sign lacks tactile exit sign
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 8 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ Reading Room 6081
Barrier #: 134C
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Strobe Height ‐ New Construction
Barrier Description:
Strobe not mounted at 80" AFF or 96" high, whichever is lower
Rec. Solution: Relocate strobe
Findings:
Strobe mounted 78" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
ADA Assessment and Survey 2014 414
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ East Exit Stairway S6090
Barrier #: 135A
X Coordinate: N/A
Barrier Area: Signage
Barrier Type: Tactile Exit Signs ‐ Stairway
Barrier Description:
Door leading directly into an exit stairway lacks tactile exit sign
Rec. Solution: Provide sign stating “EXIT STAIR DOWN (or UP)” at latch side of door
Findings:
Door to exit stair with low level illuminated sign lacks tactile exit sign
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
Performance Standard
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: Yes
Reference Dwg: 8 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ East Exit Stairway S6090
Barrier #: 135B
X Coordinate: N/A
Barrier Area: Stairways
Barrier Type: Sign ‐ Enclosed Exit Stairway (Ch 10)
Barrier Description:
Tactile stairway signage incorrectly indicates roof access, info for emergency personnel
Rec. Solution: Move existing sign and provide separate tactile stairway level sign at latch side of door
Findings:
Sign provided is misleading to the visually impaired
Quantity: EACH
Notes:
Barrier Severity: 2 Recommended Cost Est $250.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
ICC A117.1
As‐built : 1
Facility Function: Public
Implementation Priority: 3
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
ADA Assessment and Survey 2014 415
OSU ‐ VALLEY LIBRARY
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ East Exit Stairway S6090
Barrier #: 135C
X Coordinate: N/A
Barrier Area: Clear Floor Space
Barrier Type: Protruding Object
Barrier Description:
Protruding object in circulation path protrudes more than 4" between 27" and 80" high
Rec. Solution: Remove object or provide detectable warning for the visually impaired
Findings:
Fire riser hose bib protrudes 14‐1/2" at 46" high
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $550.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 307
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
Field Date: 4/22/2014 Report Date 7/31/2014
Location: Floor 6 ‐ East Exit Stairway S6090
Barrier #: 135D
X Coordinate: N/A
Barrier Area: Alarms
Barrier Type: Horn/Strobe ‐ Common Use Area
Barrier Description:
No horn/strobes in common use areas
Rec. Solution: Provide strobe in common use area
Findings:
No device provided
Quantity: EACH
Notes:
Barrier Severity: 1 Necessary Cost Est $5,500.00
Implementation Date:
Status: Open
Implementation Phase:
Code References:
2010 ADAS 702.1
As‐built : 1
Facility Function: Public
Implementation Priority: 1
Bldg Name: Valley Library
Y Coordinate: N/A
Performance Standard: No
Reference Dwg: 8 of 8
ADA Assessment and Survey 2014 416
COST ESTIMATE SUMMARY
SUMMARY REPORT
Cost Estimate Total $1,146,865.00
Cost Estimate ‐ Priority 1: $260,075.00
Cost Estimate ‐ Priority 2: $539,565.00
Cost Estimate ‐ Priority 3: $347,225.00
% of Total Cost Estimate: 22.68%
% of Total Cost Estimate: 47.05%
% of Total Cost Estimate: 30.28%
ADA Assessment and Survey 2014 417