Location:

4501 50th Street Camrose, Alberta Canada, T4V 5J1 Contacts:

Sean McIlveen Technical Director office: 780-608-2926 cell: 780-999-1184 [email protected]

CONTENTS Camrose Map ------------------ 03 Seating Capacity --------------- 04 Parking ------------------------- 04 Loading Dock ------------------ 05 Power --------------------------- 06 Audio --------------------------- 07 Lighting ------------------------- 09 Video ---------------------------- 10 Stage ----------------------------- 11 Rigging System ----------------- 12 Orchestra Pit -------------------- 12 Artist Rooms -------------------- 12 Wardrobe ------------------------ 13 Merchandise --------------------- 14

Kristen DeCoste Event Coordinator & Bookkeeper Office: 780-608-2924 [email protected]

Main Phone: 780-608-2922 Website: www.camroselive.ca Tickets: tickets.camroselive.ca

Page 3: VENUE TECHNICAL SPECIFICATIONScamroselive.ca/wp-content/uploads/2020/01/LPAC-Cargill-Tech-Spec … · There is no Shore (Bus) Power available. Please ensure your coach has adequate

CITY OF CAMROSE population 18,000 Service Area population 140,000

PAGE 3

FITNESS & RECREATION ALPINE FITNESS & SPORT MASSAGE CAMROSE & DISTRICT RECREATION CENTRE ANYTIME FITNESS CROSSFIT CAMROSE

Pizza Camrose Pizza-

-Unlimited Panago Pizza 73

Domino’s Pizza Hut

Papa John’s

Fast Food Chopped Leaf

Subway Wok Box

Edo Japan Tim Hortons

Wendy’s McDonald’s

A&W Restaurant Dairy Queen

Ethnic Cuisine Pan Flame

Skyway Family Restaurant Yummy Pho

Galbi Korean BBQ Kiri Japanese Cuisine

77 Sushi & Wok Lucky Dragon Buffet

Happy Chopstix Retro / CodFadder’s

Restaurants/Lounges Brown’s Social House

Norseman Inn – Gravity Lounge Hart House Wine & Tapas

Monte Carlo Restaurant The Canadian Brewhouse

Mr. Mike’s Steakhouse Casual Boston Pizza

East Side Mario’s Smitty’s / Geo’s Sports Bar

Page 4: VENUE TECHNICAL SPECIFICATIONScamroselive.ca/wp-content/uploads/2020/01/LPAC-Cargill-Tech-Spec … · There is no Shore (Bus) Power available. Please ensure your coach has adequate

SEATING CAPACITY Main Level* 447 Balcony Level 137

Total: 584 * (569 with basic holds - 7 seats removed for sound console, 8 FOH Holds)

PARKING

Located on the west side of the building and shared with University of Alberta – Augustana Campus. Request permits and define required clearance from Technical Director during advance. Transport vehicles have pull-through stalls available by loading dock. Additional parking for support and crew vehicles is available. Maps available for drivers.

Pull-through stalls

Seating Map

PAGE 4

Page 5: VENUE TECHNICAL SPECIFICATIONScamroselive.ca/wp-content/uploads/2020/01/LPAC-Cargill-Tech-Spec … · There is no Shore (Bus) Power available. Please ensure your coach has adequate

LOADING FACILITIES Loading bay is located at stage level with hydraulic lift to move equipment from parking level. Lift is located in the west parking lot and is height adjustable – stops at truck level for unloading semi-trailers, 5-Tons and 1-Ton vehicles.

Lift Dimensions: 7’ 9” Wide x 15’ 6” Deep Capacity: 10,000 lb. maximum.

Push to stage is approximately 20’ (6m). Door clearance: 7’ 6” Wide x 9’ 8” Tall

Loading Lift and Bay door

Variable height from Parking to Stage Level

accommodates all transport vehicles

Loading Room

To stage

PAGE 5

Page 6: VENUE TECHNICAL SPECIFICATIONScamroselive.ca/wp-content/uploads/2020/01/LPAC-Cargill-Tech-Spec … · There is no Shore (Bus) Power available. Please ensure your coach has adequate

POWER Four (4) company disconnects are available:

• Loading Room: 200 amp, 120/208v, 3-phase wye • Upstage Center: 100 amp, 120/208v, 3-phase wye 60 amp, 120/208v, 3-phase wye (Audio Technical Ground) • Grid-Level USC: 100 amp, 120/208v, 3-phase wye

A certified electrician or master electrician is required to tie and un-tie. Fees will be applied. Clients/Artists are required to provide their own cam-lock tails.

SHORE (BUS) POWER: There is no Shore (Bus) Power available. Please ensure your coach has adequate fuel/stocked generator.

Loading Room Upstage Center

PAGE 6

Page 7: VENUE TECHNICAL SPECIFICATIONScamroselive.ca/wp-content/uploads/2020/01/LPAC-Cargill-Tech-Spec … · There is no Shore (Bus) Power available. Please ensure your coach has adequate

AUDIO MICROPHONES & DI BOXES

04 – AKG HM1000 /w C31 capsule 02 – Audio Technica Pro 35 03 – Crown PCC 160 01 – Earthworks PM 40 02 – Earthworks QTC 50 01 – Earthworks SR 30 02 – Neumann KM 184 02 – Neumann KMS 105 02 – Neumann TLM 103 02 – Sennheiser E609 02 – Sennheiser MD 421-II 03 – Shure 55SH-II 01 – Shure Beta 52A 04 – Shure Beta 57A 06 – Shure Beta 58A 04 – Shure Beta 98D/S 01 – Shure MX412S 02 – Shure SM57 03 – Shure SM58 01 – Shure SM58 /w Switch 04 – Shure SM81-LC 01 – Rode NTG-2

02 – Radial J48 active DI 04 – Radial JDI passive DI 01 – Radial Pro AV2 DI 02 – Radial Pro DI

PLAYBACK

01 – Tascam CD-200ib Player 01– Stage Research Inc. SFX 6 Deluxe

INPUT/RETURN LOCATIONS Stage Left -------------------- DiGiCo D-Rack (96 kHz) 28 XLR input, 08 XLR return lines Stage Right ------------------ DiGiCo D-Rack (96 kHz) 28 XLR input, 08 XLR return lines Orchestra Pit --------------- 12 XLR inputs, 4 XLR return lines House Mix Position --------- 08 XLR inputs, 8 return lines Catwalk FOH 2 ------------- No XLR inputs, 6 XLR return lines Catwalk FOH 1 ------------- 02 XLR inputs, 6 XLR return lines False Prosc. Stage Left ------ 02 XLR inputs, 4 XLR return lines False Prosc. Stage Right ----- 02 XLR inputs, 4 XLR return lines Audience Chamber --------- 05 XLR inputs (throughout), 7 XLR return lines (face of apron) Balcony Rail ---------------- 01 XLR input, 10 XLR return lines (5 under balcony)

WIRELESS SYSTEMS 08 – Sennheiser EW-500-G3 Receivers 08 – Sennheiser EW-100-G3 Receivers

05 – Sennheiser SK-500-G3 Belt Pack 03 – Sennheiser SK-500-G4 Belt Pack 08 – Sennheiser SK-100-G3 Belt Pack

06 – Sennheiser SKM-500-G3 Handheld 06 – Sennheiser MMD-935 Capsules

11 – Countryman E6 Omni Earset 02 – Sennheiser LC1 Instrument Cables 03 – Sennheiser MKE 2-Gold (Flesh) 07 – Sennheiser MKE 2-Gold (Black) 05 – Sennheiser ME 4-II (Black)

CONSOLES 01 – DiGiCo SD9 Stealth Core 2 (Located at FOH) 01 – DiGiCo S21 (Monitors, supplementary only) 02 – DiGiCo Little Red Box (Monitor Slips)

FOH SYSTEM* 04 – Meyer UPQ-1P (2 High, 2 Low around Prosc.) 02 – Meyer UPA-1P (High/Low Centre Cluster) 04 – Meyer UPM-1P (Front Fill/Effect Speakers) 02 – Meyer 600 HP Subwoofers 01 – Meyer Galileo 408 DSP *House Config is L-R-C-Sub

MONITOR SYSTEM 08 – QSC KW122 Wedges

PAGE 7

Page 8: VENUE TECHNICAL SPECIFICATIONScamroselive.ca/wp-content/uploads/2020/01/LPAC-Cargill-Tech-Spec … · There is no Shore (Bus) Power available. Please ensure your coach has adequate

MIC STANDS 16 Tall, 12 Short, 06 Straight, 04 Desktop K&M pro series stands.

HOUSE BACKLINE (RENTAL FEES APPLY)

01 – Mayer Steinway Model D, 9’ 0” Concert Grand Piano (Cargill Theatre) 01 – Fielding Steinway Model B, 7’ 0” Grand Piano (Mayer Community Hall) 01 – Roland RD800 Electric Piano 01 – Fender 65’ Twin Reverb Re-issue 01 – Fender Blues Jr. III 01 – Amped SVT-3 Pro Head /w SVT-410HLF Cabinet

HOUSE MIX POSITION

The house mix position is located at the back of the auditorium in Row S, under the balcony. The allocated space is 12’ 6” Wide x 5’ 6” Deep, with 2 seats Audience-right of the area being removable for addition space. This is only operable space in the house.

SNAKE PATH

Touring snakes are required to be a minimum of 150’ to reach the House Mix Position. The pass-thru is located Down Stage Left, next to the smoke-pocket. Snakes travel through this to the Orchestra Pit via Dressing Room B, and then pulled through an 8” diameter PVC pipe to back-right of the chamber. Snake Heads/Head Racks must be Stage Left.

INTERCOM Master station is in Control Booth: 08 – 2 Channel Wired belt packs /w single muff headsets 04 – 2 Channel Wireless belt packs /w single muff headsets

Intercom location: Downstage left and right Upstage left and right Fly Operator position

Orchestra pit Dressing Rooms (A, B, C & D) Loading Room Mayer Hall

PROGRAM SOUND, PAGING & HEARING ASSIST SYSTEM

Two zones of program sound are available with two zones of paging for public and backstage. The auditorium is equipped with a Sennheiser infrared assisted hearing system. Transmitters are located on the orchestra level of the auditorium. 12 headsets are available through the Box Office.

Wardrobe Maintenance Control Booth Follow Spot Positions Auditorium Sound-Locks Box Office Coat Check House Mix Position

PAGE 8

CAN REMOVE THESE 2 CHAIRS AND

ADD 2’ X 4’ TABLE BESIDE DESK

Page 9: VENUE TECHNICAL SPECIFICATIONScamroselive.ca/wp-content/uploads/2020/01/LPAC-Cargill-Tech-Spec … · There is no Shore (Bus) Power available. Please ensure your coach has adequate

LIGHTING CONTROL/DIMMING

There are no racks of dimming in the building. Stage lighting is 100% LED. Twelve (12) portable ETC 750W dimming packs are available for incandescent fixtures. Master relay for LX Circuits is located in Control Booth.

Primary Control backbone is network using sACN protocol and ETC Net3 Gateways for DMX I/O.

ETC Gio Lighting Console is primary system control. There is no tracking backup.

ETC Unison Paradigm architectural controls run House Lights.

CIRCUITS Catwalk FOH 2 ----------------------- 24 – 20 amp U-Ground on 04 circuits Catwalk FOH 1 ----------------------- 24 – 20 amp U-Ground on 04 circuits First Electrics (LS2) ------------------ 24 – 20 amp U-Ground on 04 circuits Second Electrics (LS9) --------------- 16 – 20 amp U-Ground on 04 circuits Third Electrics (LS17) --------------- 16 – 20 amp U-Ground on 04 circuits Fourth Electrics (LS22) -------------- 24 – 20 amp U-Ground on 04 circuits (4) Floor Pocket SL ------------------ 04 – 15 amp U-Ground on 02 circuits, each (4) Floor Pocket SR ------------------ 04 – 15 amp U-Ground on 02 circuits, each Balcony Rail -------------------------- 12 – 15 amp U-Ground on 03 circuits Orchestra Pit ------------------------- 08 – 15 amp U-Ground on 02 circuits False Prosc SL ------------------------ 20 – 15 amp U-Ground on 05 circuits False Prosc SR ------------------------ 20 – 15 amp U-Ground on 05 circuits Stage Left & Right Walls ------------- 06 – 15 amp U-Ground on 03 circuits, each Upstage Wall ------------------------- 10 – 15 amp U-Ground on 05 circuits Grid Iron ------------------------------ 02 – 20 amp U-Ground on 01 circuits (3) Drop Box SL ---------------------- 08 – 20 amp U-Ground on 02 circuits, each (3) Drop Box SL ---------------------- 08 – 20 amp U-Ground on 02 circuits, each

FOLLOW SPOT 02 – STRONG Canto MK2 1200W HMI. 60’ throw from operating position (control booth) to apron. Cannot hit past Mid Stage Blackout due to obstructions.

FIXTURES 20 – ETC Desire D60 Lustr+

20 –VNSP Lens (25° – round very narrow) 20 – NSP Lens (35° – round narrow) 20 – MSP Lens (45° – round medium) 20 – MFL Lens (20° x 40° – narrow oval)

94 – ETC Source4 LED II Lustr+ Bodies 12 - 19° Lens 30 - 26° Lens 40 - 36° Lens 22 - 25°/50° Zoom Lens 24 – Cyc Adapters

PAGE 9

Page 10: VENUE TECHNICAL SPECIFICATIONScamroselive.ca/wp-content/uploads/2020/01/LPAC-Cargill-Tech-Spec … · There is no Shore (Bus) Power available. Please ensure your coach has adequate

FIXTURES (CONTINUED) 08 – Martin MH1 Moving Head (not Profile Plus) 94 – Pattern Holders 02 – Iris Kits

HOUSE HANG The house hang fixtures are moveable, however at the end of the performance all house hang fixtures must be replaced and refocused to house hang positions. All fixtures (less movers) use a 7-Color LED mixing system.

01 – Set of Top Lights 02 – Set of Front Light 02 – Set of Stage Tips (open breakup) 01 – Cyc Wash

VIDEO PROJECTION

01 - Panasonic PT-DZ10K projector with Shutter – 10,000 Lumens (mounted center, on balcony rail) 01 – Narrow Lens ET-D75LE30 01 – Film Lens ET-D75LE10

PLAYBACK

01 –Denon DBP-2012UDP - Blu-ray Player 01 - Crestron DMPS-300 switcher /w one (1) each portable input & output 01 – Arkaos Media Master Express License

STAGE VIEW One colour CCTV Camera mounted on balcony rail to feed live program to public and backstage

PROJECTION SURFACES 01 – 15’ 0” x 24’ 0” Screen (Flown on Lineset 10 as part of House Hang)

Throw from projector to screen on Lineset 10: 68’ 09 11/16”

01 – White Cyclorama (Flown on Lineset 24 as part of House Hang) Throw from projector to cyc on Lineset 24: 87’ 08 11/16” Throw from projector to cyc on Lineset 03: 59’ 01 13/16”

PORTABLE SYSTEMS 02 – Portable projectors 01- 6’ 0” wide portable tripod screen

PAGE 10

Page 11: VENUE TECHNICAL SPECIFICATIONScamroselive.ca/wp-content/uploads/2020/01/LPAC-Cargill-Tech-Spec … · There is no Shore (Bus) Power available. Please ensure your coach has adequate

STAGE Proscenium opening --------------------------- 42’ 7” Wide x 27’ 2 3/4” High Main valance trim height (fixed) -------------- 22’ 6” Onstage width (leg to leg) --------------------- 42’ 6” Apron to plaster line --------------------------- 08’ 9 1/2" to 11’ 6 3/8” in the center Plaster line to midstage blackout drape ------- 18’ 9 5/16” Plaster line to cyclorama ----------------------- 33’ 4” Plaster line to upstage wall --------------------- 36’ 11” Center line to stage right ----------------------- 38’ 7 5/8” Center line to stage left ------------------------- 38’ 9 7/8” Stage right wing --------------------------------- 09’ 0” Stage left wing ----------------------------------- 08’ 6”

STAGE DRAPES: All velour drapes are 25oz. Charisma unless otherwise noted. Main drape is on an automated line set controlled from

rigging computer, stage left. Movement is guillotine style only (does not have a traveler track).

Main Curtain --------------------- Emerald Green ---------------------- 30’ 6” Tall x 59’ 0” Wide Legs (5 pairs) --------------------- Black --------------------------------- 30’ 6” Tall x 17’ 0” Wide Borders (5 Sets) ------------------ Black --------------------------------- 08’ 3” Tall x 88’ 7” Wide Up-stage Blackout --------------- Black --------------------------------- 30’ 6” Tall x 59’ 0” Wide Mid-stage Blackout -------------- Black --------------------------------- 30’ 6” Tall x 59’ 0” Wide Cyclorama (Filled Cloth) ------- White -------------------------------- 30’ 6” Tall x 55’ 9” Wide Scrim ----------------------------- Black --------------------------------- 30’ 6” Tall x 55’ 9” Wide

STAGE FLOOR: The stage floor is sprung to accommodate dance and is rated for 150 lbs. per square foot. Stage floor is tempered Plyron, and painted black. There are no traps or elevator in the stage. Fastening is permitted.

STAGE EQUIPMENT 09 – 4’ x 8’ Staging Canadell platforms with interchangeable legs at 8, 16, 24, 32 and 40 inches. 30 – 2’ x 4’ wooden risers (to create stepped choral arrangement) 20 – Music Stands (with 20 rechargeable LED lights) 02 – 4’ x 25’ Red Carpets 01 – Lectern 08 – 18” x 18” x 30” Black Boxes 20 – Chivari Chairs – Black Resin

PAGE 11

Page 12: VENUE TECHNICAL SPECIFICATIONScamroselive.ca/wp-content/uploads/2020/01/LPAC-Cargill-Tech-Spec … · There is no Shore (Bus) Power available. Please ensure your coach has adequate

FLY SYSTEM Type ----------------------------------------- Automated Fixed & Variable Speed (ETC Vortek Classic) Total number of lines ---------------------- 24 Counterweight ----------------------------- None Capacity (Fixed) --------------------------- 2,000 lbs. at max 01 feet/second (LS2 – First LX and LS22 Fourth LX) Capacity (Variable) ------------------------ 1,200 lbs. at max 03 feet/second Max grid weight ---------------------------- Loft beams designed for a point load of 1000 lbs. plus UDL of 50 lbs/ft2 Pipes are ------------------------------------ 1 1/2" id schedule 40 at 60’ 0” Wide Pin rail -------------------------------------- Stage right at 30’ 6”, Belay-pin holes are 1 1/4”. Fire curtain --------------------------------- Smoke pocket is 1’ 6 1/2" from Plaster Line and must remain unobstructed Floor to grid height ------------------------ 63’ 0 1/2" Maximum fly height ----------------------- 61’ 0”

ORCHESTRA PIT Fixed pit under removable covers in apron. Access from Basement Level by Dressing Room D. Covers weigh approximately 250 lbs. each and require a minimum 4-person crew. There is substantial labour cost to remove and replace the traps. There is a fixed pit net under the covers with a 03’ 6” x 03’ 6” conductor opening at center.

Height to stage level 09’ 2 1/4" Width at center stage 07’ 9” Length 41’ 0”

ARTIST ROOMS GREEN ROOM

Located off stage left, via the loading room, the green room has a kitchenette, two fridges and lounge seating.

PAGE 12

Page 13: VENUE TECHNICAL SPECIFICATIONScamroselive.ca/wp-content/uploads/2020/01/LPAC-Cargill-Tech-Spec … · There is no Shore (Bus) Power available. Please ensure your coach has adequate

DRESSING ROOM A Located next to the green room, our principal dressing room has a private washroom and barrier free shower, as well as a wall-to-wall mirror with vanity lights.

GROUP DRESSING ROOMS (B, C & D)

Located on the Basement Level, all three dressing rooms have washroom stalls, and a shower. They feature wall-to-wall mirrors with vanity lights. Dressing Room B holds up to 19 people, Dressing Room C holds up to 14 people, and Dressing Room D holds up to 12 people. There are stairs and an elevator backstage to access these.

WARDROBE Located on the Basement Level, it has a washer, dryer, 2 irons, a commercial steamer and a basin sink. Easily accessed from backstage by stairs and an elevator.

PAGE 13

Page 14: VENUE TECHNICAL SPECIFICATIONScamroselive.ca/wp-content/uploads/2020/01/LPAC-Cargill-Tech-Spec … · There is no Shore (Bus) Power available. Please ensure your coach has adequate

MERCHANDISE POLICY When advancing your event with Lougheed Performing Arts Centre Staff, the Client is required to choose which merchandise sales arrangement best meets your needs, If the Client provides their own merchandise seller, that seller must provide a reconciliation count and settle the agreed percentage of gross sales dictated on the contract with the Event Duty Supervisor after the conclusion of all sales. If the Client requires that the Lougheed Performing Arts Centre provides personnel for merchandise sales, the following arrangement applies: - At least two hours before show time, the Client must provide an accurate count of all merchandise, which will be

verified by the Lougheed Performing Arts Centre prior to the commencement of sales. - If there are 4 or less items (any combination of hard and soft goods) OR any items with a quantity of 50 or less

(combined sizes per item included), the Lougheed Performing Arts Centre will provide a company volunteer for show sales, and the reconciliation will be completed by the Event Duty Supervisor and the Client.

- If there is more than 4 items (any combination of hard and soft goods) OR any items with a quantity of 50 or more

(combined sizes per item included), and this has been arranged previously, then the Lougheed Performing Arts Centre will provide paid Front of House staff to provide merchandise service, and the Client will be charged their hourly fee above the merchandise percentage in the contract and will be taken from the gross merchandise sales total.

- If the Client exceeds the maximum amount of merchandise for a volunteer seller, when they have previously dictated that there are no more than 4 total items, then only that number of items may be sold, or the Event Duty Supervisor reserves the right to withdraw Lougheed Performing Arts Centre merchandise services for the event.

PAGE 14