2
zoetis.com 1. Please refer to direction insert for the species covered 2. Mackay EM. The distribution of glucose in human blood (Scripps Metabolic Clinic). J Biological Chem. May 1932: 685-688. 3. Coldman MF, Good W. The distribution of sodium, potassium and glucose in the blood of some mammals. Comp Biochem Physiol. April 1967; 21(1): 201-206. 4. Data on file, Study Report No. 11-06-MC-D-CT-AT, Zoetis Inc. 5. Data on file, Study Report No. 11-07-VE-H-CT-AT, Zoetis Inc. 6. See the codes shown in the direction insert 7. Durham AE, McGowan CM, Fey K, et al. Pituitary pars intermedia dysfunction: diagnosis and treatment. Equine Vet Educ 2014;26(4):216-223. 8. Durham AE, Hughes KJ, Cottle HJ, et al. Type 2 diabetes mellitus with pancreatic ß-cell dysfunction in 3 horses confirmed with minimal model analysis. Equine Vet J 2009;41(9):924-929. 9. Frank N, Geor RJ, Durham AE, et al. Equine metabolic syndrome. J Vet Intern Med 2010;24:467-475. 10. Hackett ES, McCue PM. Evaluation of a veterinary glucometer for use in horses. J. Vet. Intern. Med. 2010;24:617-621. All trademarks are the property of Zoetis Services LLC or a related company or a licensor unless otherwise noted. © 2016 Zoetis Services LLC. All rights reserved; ATK-00086 VETERINARY BLOOD GLUCOSE METER 1 AlphaTRAK blood glucose meter 25 AlphaTRAK test strips 1 lancing device 30 blood sample lancets 1 control solution 1 user guide 1 diabetes diary ALPHATRAK STARTER KIT Accurately monitors blood glucose levels in newborn foals Helps determine the risk of laminitis linked with “Cushing’s disease” (malfunction in the pars intermedia of the pituitary gland)  7 Calculates the risk of diabetes mellitus  7,8 Confirms insulin resistance linked with equine metabolic syndrome 9 Similar results to those obtained using reference methods 5,10 and more accurate than portable human blood glucose meters 5 FOCUS: on horses VETERINARY BLOOD GLUCOSE METER DIAGNOSTICS BY ZOETIS Calibrated for animals 1 which makes all the difference! Small sample volume Long shelf life test strips Extended measurement range DESIGNED SPECIFICALLY FOR ANIMALS Sampling on the left or right of the test strip Quick result Inbuilt calibration for each species Portable meter More accurate than portable human blood glucose meters IDEAL FOR GLUCOSE CURVES AT25D17 - Adv Alphatrak avril 17 - Conception graphique : © Groupe Axxess

VETERINARY BLOOD GLUCOSE METER Calibrated for animals

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: VETERINARY BLOOD GLUCOSE METER Calibrated for animals

zoetis.com

1. Please refer to direction insert for the species covered2. Mackay EM. The distribution of glucose in human blood (Scripps Metabolic Clinic). J Biological Chem. May 1932: 685-688. 3. Coldman MF, Good W. The distribution of sodium, potassium and glucose in the blood of some mammals. Comp Biochem Physiol. April 1967; 21(1): 201-206. 4. Data on fi le, Study Report No. 11-06-MC-D-CT-AT, Zoetis Inc. 5. Data on fi le, Study Report No. 11-07-VE-H-CT-AT, Zoetis Inc.6. See the codes shown in the direction insert7. Durham AE, McGowan CM, Fey K, et al. Pituitary pars intermedia dysfunction: diagnosis and treatment. Equine Vet Educ 2014;26(4):216-223.8. Durham AE, Hughes KJ, Cottle HJ, et al. Type 2 diabetes mellitus with pancreatic ß-cell dysfunction in 3 horses confi rmed with minimal model analysis. Equine Vet J 2009;41(9):924-929.9. Frank N, Geor RJ, Durham AE, et al. Equine metabolic syndrome. J Vet Intern Med 2010;24:467-475.10. Hackett ES, McCue PM. Evaluation of a veterinary glucometer for use in horses. J. Vet. Intern. Med. 2010;24:617-621.

All trademarks are the property of Zoetis Services LLC or a related company or a licensor unless otherwise noted. © 2016 Zoetis Services LLC. All rights reserved; ATK-00086

VETERINARY BLOOD GLUCOSE METER

1 AlphaTRAK blood glucose meter25 AlphaTRAK test strips1 lancing device30 blood sample lancets1 control solution1 user guide1 diabetes diary

ALPHATRAK STARTER KIT

◗ Accurately monitors blood glucose levels in newborn foals

◗ Helps determine the risk of laminitis linked with “Cushing’s disease” (malfunction in the pars intermedia of the pituitary gland) 7

◗ Calculates the risk of diabetes mellitus 7,8

◗ Confi rms insulin resistance linked with equine metabolic syndrome 9

◗ Similar results to those obtained using reference methods 5,10 and more accurate than portable human blood glucose meters 5

FOCUS: on horses

VETERINARY BLOOD GLUCOSE METER

DIAGNOSTICS BY ZOETIS

Calibrated for animals 1…

which makes all the di� erence!

Small sample volumeLong shelf life test strips

Extended measurement range

DESIGNED SPECIFICALLY FOR ANIMALS

Sampling on the left or right of the test strip Quick result

Inbuilt calibration for each species

Portable meterMore accurate than portable human blood glucose meters

IDEAL FOR GLUCOSE CURVES

AT25

D17 -

Adv

Alph

atra

k avr

il 17 -

Conc

eptio

n gra

phiqu

e : ©

Grou

pe A

xxes

s

VETERINARY BLOOD GLUCOSE METER

1 AlphaTRAK blood glucose meter25 AlphaTRAK test strips1 lancing device30 blood sample lancets1 control solution1 user guide1 diabetes diary

ALPHATRAK STARTER KIT

◗ Accurately monitors blood glucose levels in ◗ Confi rms insulin resistance linked with equine

FOCUS: on horses

Page 2: VETERINARY BLOOD GLUCOSE METER Calibrated for animals

1 µL0.6 µL

Size required for other commonly used blood

glucose meters

4 µL2 µL

AlphaTRAK sample size

Only 0.3 µL

Small volume of blood◗ The smallest sample volume on the market◗ Avoids blood draw: saves time, less stress for the

animal so reduced disturbance of blood glucose

DESIGNED SPECIFICALLY FOR ANIMALSWHY AlphaTRAK?

Portable blood glucose meters use whole blood to measure the glucose levels in plasma. They are calibrated to take into account the distribution of glucose between the plasma and red blood cells in humans. AlphaTRAK accounts for the fact that the distribution of glucose between the plasma and red blood cells changes depending on the animal species being tested 1, in order to provide an accurate and specifi c blood glucose reading.

1 • GLUCOSE IS DISTRIBUTED DIFFERENTLY in human and animal blood 2,3

Comparative studies show that blood glucose measured using AlphaTRAK in dogs, cats and horses is more accurate than when using portable blood glucose meters designed for humans. 4.5

2 • HUMAN BLOOD GLUCOSE METERS ARE NOT SUITABLE for animal health

10

0

-10

-20

-30

Percentage Bias from a Commercial Reference Laboratory* Commerical reference lab is at zero on this graph.

0.1 %

-22.71 %

-28.5 %

DOG 4

Zoet

is Al

phaT

RAK

Baye

r Co

ntou

Roch

e Ac

cu-C

heck

® Av

iva

-1.6 %

-18.9 %-23 %

CAT 4

Zoet

is Al

phaT

RAK

Baye

r Co

ntou

Roch

e Ac

cu-C

heck

® Av

iva

0.44 %

-20.4 % -18.9 %

HORSE 5

Zoet

is Al

phaT

RAK

Baye

r Co

ntou

Roch

e Ac

cu-C

heck

® Av

iva

Extended measurement range ◗ Measurement of hyperglycaemia up to 750 mg/dL

(compared to 600 mg/dL for all the other meters on the market)

Long shelf life test strips◗ 18-24 months, even after opening, for easier

stock management

Blood sampling on the right or left of the test strip

◗ Practical, regardless of how the animal is restrained

Quick result◗ Rapid blood absorption thanks to a specifi cally-

designed test strip which breaks the meniscus of the blood drop

◗ Results displayed in just seconds, and only if there is a su� cient amount of blood (confi rmed by an audible “beep”)

◗ Saves time, in particular for creating glucose curves

More accurate than portable human blood glucose meters, as demonstrated by multiple studies 4,5

Inbuilt calibration for each species 1

◗ Takes into account the distribution of glucose in the blood, which is unique to each species covered

◗ Species-specifi c code, allows switching from cats to dogs (no changing of chips)

◗ Multi-species matching: ferret, horse, rat 6, mouse 6

Portable blood glucose meters use whole blood to measure the glucose levels in plasma. They are calibrated to take into account the distribution of glucose between the plasma and red blood cells in humans. AlphaTRAK accounts for the fact that the distribution of glucose between the plasma and red blood cells changes depending on the animal species glucose between the plasma and red blood cells changes depending on the animal species

7 %of glucose 3

93 %of glucose

42 %of glucose 2

58 %of glucose

12.5 %of glucose 3

87.5 %of glucose

Glucose Red Blood Cells Plasma

Portable meter ◗ Results are ready in seconds and can be

communicated directly to the owner during the visit

◗ For an easy transition from exam room to kennel