VMWARE VREALIZE OPERATIONS MANAGEMENT PACK FOR
Dell EMC XtremIO
User Guide
2 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
1. Purpose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32. Introduction to the Management Pack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2.1 How the Management Pack Collects Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32.2 Data the Management Pack Collects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32.3 Inventory Tree (Traversal Spec) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3. Dashboards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53.1 XtremIO Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53.2 XtremIO Cluster Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63.3 XtremIO Hosted VMs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73.4 XtremIO Health Investigation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83.5 XtremIO Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93.6 XtremIO Volume Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
4. Views . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .115. Reports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .136. Tags . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .147. Alerts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .158. Analysis Badges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .169. Troubleshooting the Management Pack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
9.1 Troubleshooting an Adapter Instance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .179.2 Testing Connection Failures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .179.3 Viewing System Log Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
10. Appendix I: Metrics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1911. Appendix II: Alerts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7712. Appendix III: Capacity Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89
TABLE OF CONTENTS
NOTE: This document supports the version of each product listed, as well as all subsequent versions, until a new edition replaces it.
You can find the most up-to-date technical documentation on the Blue Medora support site at: http://support.bluemedora.com.
The Blue Medora website also provides the latest product updates. If you have comments about this documentation, submit your feedback to: [email protected].
3 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
1. Purpose
The Blue Medora VMware vRealize Operations (vROps) Management Pack for Dell EMC XtremIO User Guide describes the primary features of the Management Pack for Dell EMC XtremIO, including dashboards, views, reports, alerts, and metrics that allow users to optimize the monitoring and management of XtremIO resources from within vRealize Operations.
2. Introduction to the Management Pack
The Management Pack for Dell EMC XtremIO is an embedded adapter for vRealize Operations (vROps) that monitors XtremIO systems remotely. The Management Pack retrieves data regarding resources by connecting to each supported XtremIO device.
This section includes the following topics:
• How the Management Pack Collects Data
• Data the Management Pack Collects
• Inventory Tree (Traversal Spec)
2.1 How the Management Pack Collects Data
During each data collection cycle, the Management Pack opens a REST API connection to the configured XtremIO device and queries it to retrieve metrics regarding XtremIO resources.
The collection interval for the adapter instance resource determines how often the Management Pack collects data. The default collection interval is five minutes.
The Management Pack supports Autodiscovery and manual discovery of resources. When you enable Autodiscovery for an adapter instance, the Management Pack creates resources in vRealize Operations and collects data after the main collection query runs. If a new resource belongs to a resource kind that does not exist in vROps, the Management Pack creates the resource kind.
2.2 Data the Management Pack Collects
The Management Pack can collect performance data, relationships, and events for the following XtremIO resources:
1. Adapter Instance (XtremIO Management Server)
2. Battery Backup Unit
3. Cluster
4. Data Protection Group
5. Disk Array Enclosure
6. Host Interface
7. InfiniBand Switch
8. Local Disk
9. PSU
10. Snapshot
11. SSD
12. Storage Controller
13. Volume
14. X-Brick
4 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
2.3 Inventory Tree (Traversal Spec)
The Inventory Tree (Traversal Spec) feature within vROps allows you to easily navigate your environment. The hierarchical structure implicitly shows relationships among resource kinds and enables quick drill-downs to root-cause issues.
In addition to internal relationships, the Management Pack also includes the following external relationships:
• Volume -> VMware Datastore
Figure 1: Example Traversal Spec
5 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
3. Dashboards
Dashboards are the primary user interface that allow users to monitor Dell EMC XtremIO resources from within vRealize Operations.
The following dashboards are available in the Management Pack:
• XtremIO Overview
• XtremIO Cluster Overview
• XtremIO Hosted VMs
• XtremIO Health Investigation
• XtremIO Performance
• XtremIO Volume Overview
3.1 XtremIO Overview
The XtremIO Overview dashboard provides at-a-glance heatmap views depicting the overall health of your XtremIO resources.
Figure 2: XtremIO Overview Dashboard
6 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
3.2 XtremIO Cluster Overview
The XtremIO Cluster Overview dashboard displays alerts and metrics for a selected cluster and provides at-a-glance health status badges for all resources within that cluster.
Figure 3: XtremIO Cluster Overview Dashboard
7 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
3.3 XtremIO Hosted VMs
The XtremIO Hosted VMs dashboard allows you to select a Virtual Machine to view its related Datastore, Volume, and Cluster, as well as KPIs for the Virtual Machine and related resource kinds.
Figure 4: XtremIO Hosted VMs Dashboard
8 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
3.4 XtremIO Health Investigation
The XtremIO Health Investigation dashboard provides at-a-glance health status badges for all resources in your XtremIO environment. Click on a resource from the Environment Overview selector to further investigate its health through selected metric charts, KPIs, and any alerts related to that resource.
Figure 5: XtremIO Health Investigation Dashboard
9 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
3.5 XtremIO Performance
The XtremIO Performance dashboard is useful for determining performance problems in your XtremIO environment. Select a cluster on the left to view its workload information and KPIs. View additional KPIs for related resource kinds by selecting the resource on the left to populate the values on the right.
Figure 6: XtremIO Performance Dashboard
10 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
3.6 XtremIO Volume Overview
The XtremIO Volume Overview dashboard allows you to select a volume to view its alerts, health status, properties, metrics, and relationships.
Figure 7: XtremIO Volume Overview Dashboard
11 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
4. Views
The vROps Management Pack for Dell EMC XtremIO creates views that allow the user to view statistics of metrics for various XtremIO resources. The views help give a broad picture of the entire system, as opposed to a more in depth view.
The views available in the Management Pack are:
• Dell EMC XtremIO Active Alerts• Dell EMC XtremIO Adapter Instance Capacities• Dell EMC XtremIO Adapter Instance KPIs• Dell EMC XtremIO Battery Backup Unit Capacities• Dell EMC XtremIO Battery Backup Unit KPIs• Dell EMC XtremIO Battery Backup Unit Properties• Dell EMC XtremIO Cluster Capacities• Dell EMC XtremIO Cluster KPIs• Dell EMC XtremIO Cluster Latency, IOPS, and
Throughput• Dell EMC XtremIO Cluster Properties• Dell EMC XtremIO Data Protection Group Capacities• Dell EMC XtremIO Data Protection Group IOPS and
Throughput• Dell EMC XtremIO Data Protection Group KPIs• Dell EMC XtremIO Data Protection Group Properties• Dell EMC XtremIO Disk Array Enclosure KPIs• Dell EMC XtremIO Disk Array Enclosure Properties• Dell EMC XtremIO Health• Dell EMC XtremIO Host Interface Capacities• Dell EMC XtremIO Host Interface Latency, IOPS,
and Throughput• Dell EMC XtremIO Host Interface Properties
• Dell EMC XtremIO InfiniBand Switch KPIs• Dell EMC XtremIO InfiniBand Switch Properties• Dell EMC XtremIO Local Disk KPIs• Dell EMC XtremIO Local Disk Properties• Dell EMC XtremIO PSU KPIs• Dell EMC XtremIO PSU Properties• Dell EMC XtremIO Snapshot Properties• Dell EMC XtremIO SSD Capacities• Dell EMC XtremIO SSD IOPS and Throughput• Dell EMC XtremIO SSD KPIs• Dell EMC XtremIO SSD Properties• Dell EMC XtremIO Storage Controller KPIs• Dell EMC XtremIO Storage Controller Properties• Dell EMC XtremIO Volume Capacities• Dell EMC XtremIO Volume KPIs• Dell EMC XtremIO Volume Latency, IOPS, and
Throughput• Dell EMC XtremIO Volume Properties• Dell EMC XtremIO X-Brick KPIs• Dell EMC XtremIO X-Brick Properties• Dell EMC XtremIO XtremIO Management Server
Properties
12 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
To access the Management Pack views, go to Environment > All Objects > Dell EMC XtremIO Adapter and double-click on the desired Object (resource). Select the Details tab, then Views. The available views for that resource are listed and can be selected.
Figure 8: Accessing Management Pack Views
13 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
5. Reports
The Management Pack for Dell EMC XtremIO contains five out-of-the-box reports, as listed below. Most reports contain one or more of the views listed in section “4. Views”. These reports can be exported and easily shared with key stakeholders in either .pdf or .csv formats.
• Dell EMC XtremIO Capacity
• Dell EMC XtremIO Health and Availability
• Dell EMC XtremIO KPIs
• Dell EMC XtremIO Performance
• Dell EMC XtremIO Properties
To access the Management Pack reports, go to Environment > All Objects > Dell EMC XtremIO Adapter and double-click on the desired Object (resource). Select the Reports tab, then Report Templates.
To run the selected report, click the Run Template icon ( ), then click Generated Reports, to select the report in your preferred format.
Figure 9: Accessing Management Pack Reports
14 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
6. Tags
To further customize how your Management Pack dashboards are displayed, the following tags (containers) are currently available for filtering:
• Dell EMC XtremIO
• Dell EMC XtremIO Clusters
• Dell EMC XtremIO Related Datastores
• Dell EMC XtremIO Related Hosts
• Dell EMC XtremIO Related VMs
• Dell EMC XtremIO to VMware
To select a tag, perform the following steps:
NOTE: Depending on the dashboard, the steps for selecting a tag may vary slightly.
1. Navigate to the dashboard you want to filter.
2. Select Edit ( ) on the widget you want to filter.
3. In the window that appears, under Filter, expand the ‘Dell EMC XtremIO’ tags to see the available options.
4. Select the desired tag and click Save.
Figure 10: Edit Widget Window
15 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
7. Alerts
The Management Pack pulls alerts and events from XtremIO resources and displays them in vRealize Operations as alerts. Refer to section “11. Appendix II: Alerts” for the full list of alerts.
Figure 11: Alert Example
16 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
8. Analysis Badges
Using the predictive analytics capabilities of the vROps Analysis Badges through capacity definitions, the Management Pack for Dell EMC XtremIO populates capacity and utilization breakdowns for several XtremIO resource kinds. Refer to section “12. Appendix III: Capacity Definitions” for the full list of resource kinds and capacity definitions.
Figure 12: Analysis Badge Example
17 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
9. Troubleshooting the Management Pack
Known troubleshooting information can help you diagnose and correct common problems with the Management Pack for Dell EMC XtremIO.
This section includes the following topics:
• Troubleshooting an Adapter Instance
• Testing Connection Failures
• Viewing System Log Files
9.1 Troubleshooting an Adapter Instance
Perform these general troubleshooting steps to diagnose and correct problems with an adapter instance:
• Edit the adapter instance and click Test Connection to verify the connection to vROps. Refer to section “9.2 Testing Connection Failures”.
• View the collection status and collection state for the adapter instance resource on the Inventory Explorer page in vROps.
• Check the adapter and collector logs for errors. Refer to section “9.3 Viewing System Log Files”, for details.
9.2 Testing Connection Failures
When clicking Test Connection in the Manage Solution window when adding an adapter instance, the following connection errors are possible.
9.2.1 Bad User Name/Password
Ensure the correct XtremIO User Name and Password were entered.
9.2.2 Bad Port/Host
Ensure the correct port and host were entered. The default port is 443. The Management Pack supports IPv4 and IPv6.
9.2.3 Non-numeric Timeout Value
The Timeout value must be an integer. The minimum value for Timeout is 15 and the maximum value is 300.
9.2.4 Negative Timeout Value
The Timeout value is below the minimum value of 15.
18 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
9.3 Viewing System Log Files
You can view adapter errors in the adapter and collector log files. You can view the adapter and collector log files in the vROps user interface or in an external log viewer.
• The adapter log files are in the $VCOPS_BASE/user/log/adapters/EMCXtremIOAdapter/ folder.
• The collector log files are in the $VCOPS_BASE/user/log/ folder.
The logging level is set to WARNING by default. To troubleshoot issues, set the logging level to INFO. To view detailed messages, including micro steps, queries, and returned results, set the logging level to DEBUG.
You can set the base log level for the collector via Administrator > Support > Logs > Select COLLECTOR folder > Select Edit Properties icon > Edit Root logger level.
NOTE: If you set the logging level to DEBUG, log files can become large very quickly. Set the logging level to DEBUG only for short periods of time.
For complete information about viewing log files and modifying log levels, refer to the VMware vRealize Operations online help.
19 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
10. Appendix I: Metrics
The Management Pack for Dell EMC XtremIO collects the following metrics by XtremIO Resource Kinds.
Table 1: Management Pack Metrics
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Adapter Instance Details Build string The number of the XMS build.
Dell EMC XtremIO Adapter Instance Details DB Version string The version number of the database.
Dell EMC XtremIO Adapter Instance Details Days of Records
In Log integer Days in Event Log (the number of days of records that are currently in the log).
Dell EMC XtremIO Adapter Instance Details IP Version string
The IP version used by the XMS for both southbound (towards clusters) and northbound.
Dell EMC XtremIO Adapter Instance Details ISCSI Route
Count floatThe aggregated amount of iSCSI routes for all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Details Initiator Group
Count floatThe aggregated value of Initiator Groups that currently exist in all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Details Logs Size float The aggregated log size of all clusters
managed by the XMS.
Dell EMC XtremIO Adapter Instance Details Management
Interface stringThe physical network interface used by the XMS to communicate with the clusters.
Dell EMC XtremIO Adapter Instance Details
Maximum Records In Event Log
floatThe aggregated value of maximum records in the Event Logs of all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Details Mode string Determines whether NTP is
automatically or manually configured.
Dell EMC XtremIO Adapter Instance Details Overall Efficiency
Ratio floatThe aggregated value of the ratio of provisioned Volume capacity to the cluster's actual used physical capacity.
Dell EMC XtremIO Adapter Instance Details REST API
Protocol Version string Exposes the supported RESTful API version.
Dell EMC XtremIO Adapter Instance Details Server Name string The fully qualified name of the XMS
server.
Dell EMC XtremIO Adapter Instance Details Software Version string
XMS software version. This version should be identical to the cluster's software version, unless it is undergoing a special process (e.g. upgrade).
Dell EMC XtremIO Adapter Instance Details System Count float The number of clusters managed by
the XMS.
Dell EMC XtremIO Adapter Instance Details Uptime string The amount of time passed since the
XMS was last rebooted.
20 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Adapter Instance Details User Account
Count integer The number of user accounts associated with the XMS.
Dell EMC XtremIO Adapter Instance Details Version string The installed XtremIO XMS version.
Dell EMC XtremIO Adapter Instance Details Volume Count float Number of volumes for all clusters
managed by the XMS.
Dell EMC XtremIO Adapter Instance Details Wrong CN In CSR string
Triggers an Alert if the default CSR (Certificate Signing Request) contains CN which is not the XMS's FQDN.
Dell EMC XtremIO Adapter Instance Details XMS Gateway string XMS's default gateway IP address.
Dell EMC XtremIO Adapter Instance Details XMS IP string IP address of the XMS.
Dell EMC XtremIO Adapter Instance Details XMS IP Subnet string
XMS IP address and subnet mask. The XMS IP address is optional. It is not required if this command is only used to update the Storage Controller's IP or IPMI addresses.
Dell EMC XtremIO Adapter Instance Disk Average Latency float The aggregated latency for all clusters
managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Average Latency
128KB floatThe aggregated latency of 128KB operations for all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Average Latency
16KB floatThe aggregated latency of 16KB operations for all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Average Latency
1KB floatThe aggregated latency of 1KB operations for all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Average Latency
1MB floatThe aggregated latency of 1MB operations for all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Average Latency
256KB floatThe aggregated latency of 256KB operations for all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Average Latency
2KB floatThe aggregated latency of 2KB operations for all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Average Latency
32KB floatThe aggregated latency of 32KB operations for all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Average Latency
4KB floatThe aggregated latency of 4KB operations for all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Average Latency
512B floatThe aggregated latency of 512B operations for all clusters managed by the XMS.
21 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Adapter Instance Disk Average Latency
512KB floatThe aggregated latency of 512KB operations for all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Average Latency
64KB floatThe aggregated latency of 64KB operations for all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Average Latency
8KB floatThe aggregated latency of 8KB operations for all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk
Average Latency Greater Than 1MB
floatThe aggregated latency of operations greater than 1MB for all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk
Disk Space Secondary Utilization Level
stringDisk space secondary utilization level. Measures XMS's aggregated value of capacity monitoring.
Dell EMC XtremIO Adapter Instance Disk Disk Space
Utilization Level string
Monitors the aggregated amount of free disk space on the XMS system for the root partition. An Alert is triggered when the disk utilization of the root portion exceeds the threshold percentage.
Dell EMC XtremIO Adapter Instance Disk Free Disk Space
Secondary floatAggregated free disk space at the secondary utilization level for all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Free Space Disk
Space (/root) floatAggregated free disk space of the root partition for all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk IOPS float
The aggregated value of total read and write real-time input/output operations per second from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk IOPS 128KB float
The aggregated value of total read and write real-time input/output operations per second for 128KB operations from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk IOPS 16KB float
The aggregated value of total read and write real-time input/output operations per second for 16KB operations from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk IOPS 1KB float
The aggregated value of total read and write real-time input/output operations per second for 1KB operations from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk IOPS 1MB float
The aggregated value of total read and write real-time input/output operations per second for 1MB operations from all clusters managed by the XMS.
22 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Adapter Instance Disk IOPS 256KB float
The aggregated value of total read and write real-time input/output operations per second for 256KB operations from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk IOPS 2KB float
The aggregated value of total read and write real-time input/output operations per second for 2KB operations from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk IOPS 32KB float
The aggregated value of total read and write real-time input/output operations per second for 32KB operations from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk IOPS 4KB float
The aggregated value of total read and write real-time input/output operations per second for 4KB operations from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk IOPS 512B float
The aggregated value of total read and write real-time input/output operations per second for 512B operations from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk IOPS 512KB float
The aggregated value of total read and write real-time input/output operations per second for 512KB operations from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk IOPS 64KB float
The aggregated value of total read and write real-time input/output operations per second for 64KB operations from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk IOPS 8KB float
The aggregated value of total read and write real-time input/output operations per second for 8KB operations from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk IOPS By Block float
The aggregated value of total read and write real-time input/output operations per second for Block operations from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk IOPS Greater
Than 1MB float
The aggregated value of total read and write real-time input/output operations per second for operations greater than 1MB from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Logical Space In
Use float Aggregated used logical disk space for all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk
Maximum Observation of IOPS
integer Maximum observed value of metric IOPS.
Dell EMC XtremIO Adapter Instance Disk
Maximum Observation of Throughput
float Maximum observed value of metric Throughput.
23 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Adapter Instance Disk Read / Write Ratio float The ratio of read to write IOPS.
Dell EMC XtremIO Adapter Instance Disk Read IOPS float IOPS of read input/output operations
from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Read IOPS
128KB floatIOPS of 128KB read input/output operations from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Read IOPS 16KB float
IOPS of 16KB read input/output operations from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Read IOPS 1KB float
IOPS of 1KB read input/output operations from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Read IOPS 1MB float
IOPS of 1MB read input/output operations from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Read IOPS
256KB floatIOPS of 256KB read input/output operations from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Read IOPS 2KB float
IOPS of 2KB read input/output operations from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Read IOPS 32KB float
IOPS of 32KB read input/output operations from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Read IOPS 4KB float
IOPS of 4KB read input/output operations from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Read IOPS 512B float
IOPS of 512B read input/output operations from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Read IOPS
512KB floatIOPS of 512KB read input/output operations from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Read IOPS 64KB float
IOPS of 64KB read input/output operations from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Read IOPS 8KB float
IOPS of 8KB read input/output operations from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Read IOPS By
Block floatThe aggregated value of Block input/output per second handled by all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk
Read IOPS Greater Than 1MB
floatIOPS of read input/output operations greater than 1MB from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Read Latency float XMS's total real-time average latency
of read operations.
24 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Adapter Instance Disk Read Latency
128KB float XMS's total real-time average latency of 128KB read operations.
Dell EMC XtremIO Adapter Instance Disk Read Latency
16KB float XMS's total real-time average latency of 16KB read operations.
Dell EMC XtremIO Adapter Instance Disk Read Latency
1KB float XMS's total real-time average latency of 1KB read operations.
Dell EMC XtremIO Adapter Instance Disk Read Latency
1MB float XMS's total real-time average latency of 1MB read operations.
Dell EMC XtremIO Adapter Instance Disk Read Latency
256KB float XMS's total real-time average latency of 256KB read operations.
Dell EMC XtremIO Adapter Instance Disk Read Latency
2KB float XMS's total real-time average latency of 2KB read operations.
Dell EMC XtremIO Adapter Instance Disk Read Latency
32KB float XMS's total real-time average latency of 32KB read operations.
Dell EMC XtremIO Adapter Instance Disk Read Latency
4KB float XMS's total real-time average latency of 4KB read operations.
Dell EMC XtremIO Adapter Instance Disk Read Latency
512B float XMS's total real-time average latency of 512B read operations.
Dell EMC XtremIO Adapter Instance Disk Read Latency
512KB float XMS's total real-time average latency of 512KB read operations.
Dell EMC XtremIO Adapter Instance Disk Read Latency
64KB float XMS's total real-time average latency of 64KB read operations.
Dell EMC XtremIO Adapter Instance Disk Read Latency
8KB float XMS's total real-time average latency of 8KB read operations.
Dell EMC XtremIO Adapter Instance Disk
Read Latency Greater Than 1MB
float XMS's total real-time average latency of read operations greater than 1MB.
Dell EMC XtremIO Adapter Instance Disk Read Throughput float
The aggregated value of real-time read bandwidth from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Read Throughput
128KB floatThe aggregated value of real-time read bandwidth for 128KB operations from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Read Throughput
16KB floatThe aggregated value of real-time read bandwidth for 16KB operations from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Read Throughput
1KB floatThe aggregated value of real-time read bandwidth for 1KB operations from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Read Throughput
1MB floatThe aggregated value of real-time read bandwidth for 1MB operations from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Read Throughput
256KB floatThe aggregated value of real-time read bandwidth for 256KB operations from all clusters managed by the XMS.
25 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Adapter Instance Disk Read Throughput
2KB floatThe aggregated value of real-time read bandwidth for 2KB operations from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Read Throughput
32KB floatThe aggregated value of real-time read bandwidth for 32KB operations from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Read Throughput
4KB floatThe aggregated value of real-time read bandwidth for 4KB operations from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Read Throughput
512B floatThe aggregated value of real-time read bandwidth for 512B operations from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Read Throughput
512KB floatThe aggregated value of real-time read bandwidth for 512KB operations from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Read Throughput
64KB floatThe aggregated value of real-time read bandwidth for 64KB operations from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Read Throughput
8KB floatThe aggregated value of real-time read bandwidth for 8KB operations from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Read Throughput
By Block floatThe aggregated value of real-time read bandwidth for Block operations from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk
Read Throughput Greater Than 1MB
floatThe aggregated value of real-time read bandwidth for operations greater than 1MB from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Thin Provisioning
Savings float The aggregated value of percentage of Volume capacity not in use.
Dell EMC XtremIO Adapter Instance Disk Throughput float
The aggregated value of total real-time read and write bandwidth for all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Throughput
128KB floatThe aggregated value of total real-time read and write bandwidth of 128KB operations for all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Throughput 16KB float
The aggregated value of total real-time read and write bandwidth of 16KB operations for all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Throughput 1KB float
The aggregated value of total real-time read and write bandwidth of 1KB operations for all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Throughput 1MB float
The aggregated value of total real-time read and write bandwidth of 1MB operations for all clusters managed by the XMS.
26 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Adapter Instance Disk Throughput
256KB floatThe aggregated value of total real-time read and write bandwidth of 256KB operations for all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Throughput 2KB float
The aggregated value of total real-time read and write bandwidth of 2KB operations for all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Throughput 32KB float
The aggregated value of total real-time read and write bandwidth of 32KB operations for all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Throughput 4KB float
The aggregated value of total real-time read and write bandwidth of 4KB operations for all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Throughput 512B float
The aggregated value of total real-time read and write bandwidth of 512B operations for all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Throughput
512KB floatThe aggregated value of total real-time read and write bandwidth of 512KB operations for all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Throughput 64KB float
The aggregated value of total real-time read and write bandwidth of 64KB operations for all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Throughput 8KB float
The aggregated value of total real-time read and write bandwidth of 8KB operations for all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Throughput By
Block floatThe aggregated value of total real-time read and write bandwidth of Block operations for all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk
Throughput Greater Than 1MB
floatThe aggregated value of total real-time read and write bandwidth of operations greater than 1MB for all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Write IOPS float
The aggregated value of total write real-time input/output operations per second from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Write IOPS 128KB float
The aggregated value of total write real-time input/output 128KB operations per second from all clusters managed by the XMS.
27 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Adapter Instance Disk Write IOPS 16KB float
The aggregated value of total write real-time input/output 16KB operations per second from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Write IOPS 1KB float
The aggregated value of total write real-time input/output 1KB operations per second from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Write IOPS 1MB float
The aggregated value of total write real-time input/output 1MB operations per second from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Write IOPS 256KB float
The aggregated value of total write real-time input/output 256KB operations per second from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Write IOPS 2KB float
The aggregated value of total write real-time input/output 2KB operations per second from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Write IOPS 32KB float
The aggregated value of total write real-time input/output 32KB operations per second from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Write IOPS 4KB float
The aggregated value of total write real-time input/output 4KB operations per second from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Write IOPS 512B float
The aggregated value of total write real-time input/output 512B operations per second from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Write IOPS 512KB float
The aggregated value of total write real-time input/output 512KB operations per second from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Write IOPS 64KB float
The aggregated value of total write real-time input/output 64KB operations per second from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Write IOPS 8KB float
The aggregated value of total write real-time input/output 8KB operations per second from all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Write IOPS By
Block floatThe aggregated value of input/output per second handled by all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk
Write IOPS Greater Than 1MB
floatThe aggregated value of total write real-time input/output operations greater than 1MB per second from all clusters managed by the XMS.
28 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Adapter Instance Disk Write Latency float
Cluster's aggregated value of total real-time average latency of write operations.
Dell EMC XtremIO Adapter Instance Disk Write Latency
128KB floatCluster's aggregated value of total real-time average latency of 128KB write operations.
Dell EMC XtremIO Adapter Instance Disk Write Latency
16KB floatCluster's aggregated value of total real-time average latency of 16KB write operations.
Dell EMC XtremIO Adapter Instance Disk Write Latency
1KB floatCluster's aggregated value of total real-time average latency of 1KB write operations.
Dell EMC XtremIO Adapter Instance Disk Write Latency
1MB floatCluster's aggregated value of total real-time average latency of 1MB write operations.
Dell EMC XtremIO Adapter Instance Disk Write Latency
256KB floatCluster's aggregated value of total real-time average latency of 256KB write operations.
Dell EMC XtremIO Adapter Instance Disk Write Latency
2KB floatCluster's aggregated value of total real-time average latency of 2KB write operations.
Dell EMC XtremIO Adapter Instance Disk Write Latency
32KB floatCluster's aggregated value of total real-time average latency of 32KB write operations.
Dell EMC XtremIO Adapter Instance Disk Write Latency
4KB floatCluster's aggregated value of total real-time average latency of 4KB write operations.
Dell EMC XtremIO Adapter Instance Disk Write Latency
512B floatCluster's aggregated value of total real-time average latency of 512B write operations.
Dell EMC XtremIO Adapter Instance Disk Write Latency
512KB floatCluster's aggregated value of total real-time average latency of 512KB write operations.
Dell EMC XtremIO Adapter Instance Disk Write Latency
64KB floatCluster's aggregated value of total real-time average latency of 64KB write operations.
Dell EMC XtremIO Adapter Instance Disk Write Latency
8KB floatCluster's aggregated value of total real-time average latency of 8KB write operations.
Dell EMC XtremIO Adapter Instance Disk
Write Latency Greater Than 1MB
floatCluster's aggregated value of total real-time average latency of write operations greater than 1MB.
Dell EMC XtremIO Adapter Instance Disk Write Throughput float
The aggregated value of total real-time write bandwidth of all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Write Throughput
128KB floatThe aggregated value of total real-time write bandwidth of 128KB operations for all clusters managed by the XMS.
29 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Adapter Instance Disk Write Throughput
16KB floatThe aggregated value of total real-time write bandwidth of 16KB operations for all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Write Throughput
1KB floatThe aggregated value of total real-time write bandwidth of 1KB operations for all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Write Throughput
1MB floatThe aggregated value of total real-time write bandwidth of 1MB operations for all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Write Throughput
256KB floatThe aggregated value of total real-time write bandwidth of 256KB operations for all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Write Throughput
2KB floatThe aggregated value of total real-time write bandwidth of 2KB operations for all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Write Throughput
32KB floatThe aggregated value of total real-time write bandwidth of 32KB operations for all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Write Throughput
4KB floatThe aggregated value of total real-time write bandwidth of 4KB operations for all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Write Throughput
512B floatThe aggregated value of total real-time write bandwidth of 512B operations for all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Write Throughput
512KB floatThe aggregated value of total real-time write bandwidth of 512KB operations for all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Write Throughput
64KB floatThe aggregated value of total real-time write bandwidth of 64KB operations for all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Write Throughput
8KB floatThe aggregated value of total real-time write bandwidth of 8KB operations for all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Disk Write Throughput
By Block floatThe aggregated value of current bandwidth for all clusters managed by the XMS, used to get a Snapshot of the aggregated totals by block size.
Dell EMC XtremIO Adapter Instance Disk
Write Throughput Greater Than 1MB
floatThe aggregated value of total real-time write bandwidth of operations greater than 1MB for all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance Status Object Severity string
The XMS's severity, based on severity level of current Alerts (Alerts still uncleared) for this XMS. Possible values are 'clear', 'information', 'minor', 'major', and 'critical'.
Dell EMC XtremIO Adapter Instance Status
Value of 100 for Capacity Calculations
integer Metric generated with purpose of Value of 100 for Capacity Calculations.
30 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Adapter Instance
User Configuration
Allow Empty Password string Whether or not the user account can
have a blank password.
Dell EMC XtremIO Adapter Instance
User Configuration
Default User Inactivity Timeout integer
The XMS's default timeout period. The XMS logs the user out when a timeout period is not set.
Dell EMC XtremIO Adapter Instance
XMS Performance CPU Utilization float The current XMS's CPU utilization.
Dell EMC XtremIO Adapter Instance
XMS Performance
Memory Utilization Level string Monitors the aggregated free memory
on all clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance
XMS Performance RAM Free float Aggregated free memory for all
clusters managed by the XMS.
Dell EMC XtremIO Adapter Instance
XMS Performance RAM Total float Total available RAM for all clusters
managed by the XMS.
Dell EMC XtremIO Adapter Instance
XMS Performance RAM Usage float RAM usage for all clusters managed
by the XMS.
Dell EMC XtremIO Adapter Instance
XMS Performance Used Memory float Memory in use.
Dell EMC XtremIO Adapter Instance Relationships Cluster Children string List of child Cluster resources
Dell EMC XtremIO Adapter Instance Relationships Dell EMC XtremIO
Tag Parents string List of parent Dell EMC XtremIO Tag resources
Dell EMC XtremIO Tag Relationships Cluster Children string List of children Cluster resources
Dell EMC XtremIO Tag Relationships vSphere World
Children string List of children vSphere World resources
Dell EMC XtremIO Tag Relationships
XtremIO Management Server Children
string List of children XtremIO Management Server resources
Dell EMC XtremIO Related Objects Relationships Datastore
Children string List of children Datastore resources
Dell EMC XtremIO Related Objects Relationships Host System
Children string List of children Host System resources
Dell EMC XtremIO Related VMs Relationships Virtual Machine
Children string List of children Virtual Machine resources
Dell EMC XtremIO Battery Backup Unit Details Accumulated
Daily Uptime integer Accumulated daily uptime of the battery backup unit.
Dell EMC XtremIO Battery Backup Unit Details Average Daily
Temperature integer Average daily temperature of the battery backup unit.
Dell EMC XtremIO Battery Backup Unit Details Battery Runtime integer Runtime of the battery backup unit.
Dell EMC XtremIO Battery Backup Unit Details Battery Voltage integer Battery voltage.
Dell EMC XtremIO Battery Backup Unit Details Firmware Version string Current firmware version of the BBU.
31 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Battery Backup Unit Details Hardware
Revision string Hardware level of the power supply unit.
Dell EMC XtremIO Battery Backup Unit Details Identify LED string Identify LED for the battery backup
unit.
Dell EMC XtremIO Battery Backup Unit Details Index integer Index of the battery backup unit.
Dell EMC XtremIO Battery Backup Unit Details Index In Brick integer
The BBU's index within the X-Brick, either 1 or 2. Always 1 for multiple X-Brick clusters (for all X-Bricks), but two BBUs are available for a single X-Brick cluster.
Dell EMC XtremIO Battery Backup Unit Details Input Frequency float Input frequency of the battery backup
unit.
Dell EMC XtremIO Battery Backup Unit Details Model Name string Model name for the BBU.
Dell EMC XtremIO Battery Backup Unit Details Output Current float Output current of the battery backup
unit.
Dell EMC XtremIO Battery Backup Unit Details Output Frequency integer Output frequency of the battery
backup unit.
Dell EMC XtremIO Battery Backup Unit Details Output Voltage float Output voltage of the battery backup
unit.
Dell EMC XtremIO Battery Backup Unit Details Part Number string Part number. An EMC-assigned string
identifying part (SKU).
Dell EMC XtremIO Battery Backup Unit Details Power integer Power of the battery backup unit.
Dell EMC XtremIO Battery Backup Unit Details Power Feed string A and B PSU power feeds.
Dell EMC XtremIO Battery Backup Unit Details Real Power integer Real power of the battery backup unit.
Dell EMC XtremIO Battery Backup Unit Details Serial Number string Serial number of the battery backup
unit.
Dell EMC XtremIO Battery Backup Unit Details UPS Battery
Charge In Percent integer Battery charge of the UPS in percentage.
Dell EMC XtremIO Battery Backup Unit Details
UPS Battery Uncharged In Percent
integer Percentage of the UPS battery not charged.
Dell EMC XtremIO Battery Backup Unit Details UPS Load In
Percent integer UPS load in percentage.
Dell EMC XtremIO Battery Backup Unit Details UPS Load
Percent Level string The load percent level of the UPS.
Dell EMC XtremIO Battery Backup Unit Details UPS Voltage integer UPS voltage of the battery backup
unit.
Dell EMC XtremIO Battery Backup Unit Status Enabled State string
Indicates whether the battery backup unit is currently enabled or disabled, either by the user or the cluster.
32 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Battery Backup Unit Status FRU Lifecycle
State string FRU lifecycle state of the battery backup unit.
Dell EMC XtremIO Battery Backup Unit Status FRU Replace
Failure Reason string The reason (if any) for the FRU replace failure.
Dell EMC XtremIO Battery Backup Unit Status Firmware Version
Error string Firmware version error (if any) of the battery backup unit.
Dell EMC XtremIO Battery Backup Unit Status Is Bypass Active string Whether or not the bypass is active for
the battery backup unit.
Dell EMC XtremIO Battery Backup Unit Status Is Low Battery
Has Input string Whether or not the low battery has input.
Dell EMC XtremIO Battery Backup Unit Status Is Low Battery No
Input string Whether or not the low battery has no input.
Dell EMC XtremIO Battery Backup Unit Status Is Low Battery
Runtime string Whether or not there is low battery runtime.
Dell EMC XtremIO Battery Backup Unit Status Is UPS Overload string Whether or not the UPS is overloaded.
Dell EMC XtremIO Battery Backup Unit Status Object Severity string Object severity of the battery backup
unit.
Dell EMC XtremIO Battery Backup Unit Status Outlet 1 Status string Outlet 1 status for the battery backup
unit.
Dell EMC XtremIO Battery Backup Unit Status Outlet 2 Status string Outlet 2 status of the battery backup
unit.
Dell EMC XtremIO Battery Backup Unit Status Status LED string Status LED for the battery backup unit.
Dell EMC XtremIO Battery Backup Unit Status UPS Alarm string UPS alarm of the battery backup unit.
Dell EMC XtremIO Battery Backup Unit Status UPS Connection
State string The state of the UPS connection.
Dell EMC XtremIO Battery Backup Unit Status UPS Input string UPS input.
Dell EMC XtremIO Battery Backup Unit Status UPS Need Battery
Replacement string Whether or not the UPS needs a battery replacement.
Dell EMC XtremIO Battery Backup Unit Status UPS Status string The status of the UPS.
Dell EMC XtremIO Battery Backup Unit Status
Value of 100 for Capacity Calculations
integer Metric generated with purpose of Value of 100 for Capacity Calculations.
Dell EMC XtremIO Battery Backup Unit Relationships X-Brick Parents string List of parent X-Brick resources
Dell EMC XtremIO Cluster Details
CHAP Authentication Mode
string Describes the CHAP mode for Initiator discovery (applicable for iSCSI only).
Dell EMC XtremIO Cluster Details CHAP Discovery
Mode string Describes the CHAP mode for Initiator discovery (applicable for iSCSI only)..
33 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Cluster Details Compression
Factor (Text) string Text representation of the cluster's compression factor.
Dell EMC XtremIO Cluster Details Compression
Mode string Compression mode.
Dell EMC XtremIO Cluster Details
Configurable Volume Type Capability
stringDenotes whether the cluster supports the capability to configure a Volume's vol-access.
Dell EMC XtremIO Cluster Details Critical Alert
Count integer Number of critical alerts on the cluster.
Dell EMC XtremIO Cluster Details DAE Count integer Number of DAEs.
Dell EMC XtremIO Cluster Details DPG Count integer The number of DPGs.
Dell EMC XtremIO Cluster Details Data Reduction
Ratio float Data reduction ratio of the cluster.
Dell EMC XtremIO Cluster Details Data Reduction
Ratio (Text) string Text representation of the cluster's data reduction ratio.
Dell EMC XtremIO Cluster Details Debug Create
Timeout string Debug Create Timeout for the cluster.
Dell EMC XtremIO Cluster Details Dedup Ratio
(Text) string The text representation of the deduplication ratio of the cluster.
Dell EMC XtremIO Cluster Details Encryption
Supported stringThe capability parameter reflects whether Data at Rest encryption is possible for this cluster.
Dell EMC XtremIO Cluster Details Free Physical
Space In Percent integer Percentage of physical space that is free.
Dell EMC XtremIO Cluster Details IB Switch Count integer Number of IB switches
Dell EMC XtremIO Cluster Details Index integer Index of the cluster.
Dell EMC XtremIO Cluster Details Internal Volume
Count integer Number of internal volumes.
Dell EMC XtremIO Cluster Details
Last Upgrade Attempt Timestamp
string Timestamp of last upgrade attempt.
Dell EMC XtremIO Cluster Details Last Upgrade
Attempt Version string Version of the last upgrade attempt.
Dell EMC XtremIO Cluster Details License ID string Cluster's license index number.
Dell EMC XtremIO Cluster Details Major Alert Count integer Number of major alerts on the cluster.
Dell EMC XtremIO Cluster Details
Maximum Data Transfer Percent Done
integer The percentage of the maximum data transfer done.
Dell EMC XtremIO Cluster Details Maximum SSD
Count Per DPG integer The maximum number of SSDs a DPG can contain.
34 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Cluster Details Minor Alert Count integer Number of minor alerts on the cluster.
Dell EMC XtremIO Cluster Details NAA System ID string A Volume's SCSI NAA name consisting
of three elements.
Dell EMC XtremIO Cluster Details Node Count integer Number of nodes for the cluster.
Dell EMC XtremIO Cluster Details PSNT Part
Number string PSNT part number.
Dell EMC XtremIO Cluster Details SSD Count integer Number of SSDs.
Dell EMC XtremIO Cluster Details Size And Capacity string The size and capacity of the cluster.
Dell EMC XtremIO Cluster Details System Activation
Timestamp integer Cluster's activation uptime timestamp as of 1.1.1970, measured in seconds.
Dell EMC XtremIO Cluster Details System PSNT
Serial Number string Cluster's Product Serial Number tag (PSNT) serial number.
Dell EMC XtremIO Cluster Details System Software
Version string XIOS version.
Dell EMC XtremIO Cluster Details System Start
Timestamp integer Timestamp of the cluster's commencement.
Dell EMC XtremIO Cluster Details Target Port Count integer Total number of the cluster's target
ports
Dell EMC XtremIO Cluster Details UPS Count integer Total number of the cluster's BBUs.
Dell EMC XtremIO Cluster Details Volume Count integer Total number of the cluster's
provisioned Volumes.
Dell EMC XtremIO Cluster Details X-Brick Count integer Total number of X-Bricks for the
cluster.
Dell EMC XtremIO Cluster Details XEnv Count integer Number of XEnvs for the cluster.
Dell EMC XtremIO Cluster Details XMS GUID string GUID of the cluster's XMS.
Dell EMC XtremIO Cluster Disk Average Latency float Average Latency
Dell EMC XtremIO Cluster Disk Average Latency
128KB float Average Latency 128KB
Dell EMC XtremIO Cluster Disk Average Latency
16KB float Average Latency 16KB
Dell EMC XtremIO Cluster Disk Average Latency
1KB float Average Latency 1KB
Dell EMC XtremIO Cluster Disk Average Latency
1MB float Average Latency 1MB
Dell EMC XtremIO Cluster Disk Average Latency
256KB float Average Latency 256KB
35 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Cluster Disk Average Latency
2KB float Average latency for 2KB block size.
Dell EMC XtremIO Cluster Disk Average Latency
32KB float Average Latency 32KB
Dell EMC XtremIO Cluster Disk Average Latency
4KB float Average Latency 4KB
Dell EMC XtremIO Cluster Disk Average Latency
512B float Average latency for 512B block size.
Dell EMC XtremIO Cluster Disk Average Latency
512KB float Average Latency 512KB
Dell EMC XtremIO Cluster Disk Average Latency
64KB float Average Latency 64KB
Dell EMC XtremIO Cluster Disk Average Latency
8KB float Average Latency 8KB
Dell EMC XtremIO Cluster Disk
Average Latency Greater Than 1MB
float Average latency greater than 1MB for the cluster.
Dell EMC XtremIO Cluster Disk Compression
Factor float Compression factor for the cluster
Dell EMC XtremIO Cluster Disk Dedup Ratio float The deduplication ratio of the cluster.
Dell EMC XtremIO Cluster Disk Dedup Space In
Use float Deduplication space in use by the cluster.
Dell EMC XtremIO Cluster Disk Free Logical
Space In Base 10 float Free logical space in base 10
Dell EMC XtremIO Cluster Disk Free Physical
Space In Base 10 float Free physical space in base 10.
Dell EMC XtremIO Cluster Disk Free Physical
Space Level string Free physical space level of the cluster.
Dell EMC XtremIO Cluster Disk IOPS float IOPS
Dell EMC XtremIO Cluster Disk IOPS 128KB float IOPS 128KB
Dell EMC XtremIO Cluster Disk IOPS 16KB float IOPS 16KB
Dell EMC XtremIO Cluster Disk IOPS 1KB float IOPS 1KB
Dell EMC XtremIO Cluster Disk IOPS 1MB float IOPS 1MB
Dell EMC XtremIO Cluster Disk IOPS 256KB float IOPS 256KB
Dell EMC XtremIO Cluster Disk IOPS 2KB float IOPS 2KB
Dell EMC XtremIO Cluster Disk IOPS 32KB float IOPS 32KB
36 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Cluster Disk IOPS 4KB float IOPS 4KB
Dell EMC XtremIO Cluster Disk IOPS 512B float IOPS 512B
Dell EMC XtremIO Cluster Disk IOPS 512KB float IOPS 512KB
Dell EMC XtremIO Cluster Disk IOPS 64KB float IOPS 64KB
Dell EMC XtremIO Cluster Disk IOPS 8KB float IOPS 8KB
Dell EMC XtremIO Cluster Disk IOPS By Block float IOPS by block for the cluster.
Dell EMC XtremIO Cluster Disk IOPS Greater
Than 1MB float IOPS greater than 1MB for the cluster.
Dell EMC XtremIO Cluster Disk Logical Size In
Base 10 float Logical Size In Base 10
Dell EMC XtremIO Cluster Disk Logical Space float Total logical space for the cluster.
Dell EMC XtremIO Cluster Disk Logical Space In
Use float Logical space in use by the cluster.
Dell EMC XtremIO Cluster Disk Logical Space In
Use float Logical space in use.
Dell EMC XtremIO Cluster Disk Logical Space In
Use In Base 10 float Logical space in use in base 10.
Dell EMC XtremIO Cluster Disk
Maximum Observed Total IOPS
float Maximum observed value of metric Maximum Observed Total IOPS.
Dell EMC XtremIO Cluster Disk
Maximum Observed Total Throughput
float Maximum observed value of metric Maximum Observed Total Throughput.
Dell EMC XtremIO Cluster Disk Physical Space float Physical space for the cluster.
Dell EMC XtremIO Cluster Disk Physical Space In
Base 10 float Physical space in base 10.
Dell EMC XtremIO Cluster Disk Physical Space
In Use float Physical space in use on the cluster.
Dell EMC XtremIO Cluster Disk Physical Space
In Use float Physical space in use.
Dell EMC XtremIO Cluster Disk Physical Space In
Use In Base 10 float Physical space in use in base 10.
Dell EMC XtremIO Cluster Disk Physical Space
Per SSD float Physical space per SSD for the cluster.
Dell EMC XtremIO Cluster Disk Read / Write Ratio float The ratio of read to write IOPS.
37 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Cluster Disk Read IOPS float Read IOPS
Dell EMC XtremIO Cluster Disk Read IOPS
128KB float Read IOPS 128KB
Dell EMC XtremIO Cluster Disk Read IOPS 16KB float Read IOPS 16KB
Dell EMC XtremIO Cluster Disk Read IOPS 1KB float Read IOPS 1KB
Dell EMC XtremIO Cluster Disk Read IOPS 1MB float Read IOPS 1MB
Dell EMC XtremIO Cluster Disk Read IOPS
256KB float Read IOPS 256KB
Dell EMC XtremIO Cluster Disk Read IOPS 2KB float Read IOPS 2KB
Dell EMC XtremIO Cluster Disk Read IOPS 32KB float Read IOPS 32KB
Dell EMC XtremIO Cluster Disk Read IOPS 4KB float Read IOPS 4KB
Dell EMC XtremIO Cluster Disk Read IOPS 512B float Read IOPS 512B
Dell EMC XtremIO Cluster Disk Read IOPS
512KB float Read IOPS 512KB
Dell EMC XtremIO Cluster Disk Read IOPS 64KB float Read IOPS 64KB
Dell EMC XtremIO Cluster Disk Read IOPS 8KB float Read IOPS 8KB
Dell EMC XtremIO Cluster Disk Read IOPS By
Block float Read IOPS By Block
Dell EMC XtremIO Cluster Disk
Read IOPS Greater Than 1MB
float Read IOPS Greater Than 1MB
Dell EMC XtremIO Cluster Disk Read Latency float Read Latency
Dell EMC XtremIO Cluster Disk Read Latency
128KB float Read Latency 128KB
Dell EMC XtremIO Cluster Disk Read Latency
16KB float Read Latency 16KB
Dell EMC XtremIO Cluster Disk Read Latency
1KB float Read Latency 1KB
Dell EMC XtremIO Cluster Disk Read Latency
1MB float Read Latency 1MB
Dell EMC XtremIO Cluster Disk Read Latency
256KB float Read Latency 256KB
Dell EMC XtremIO Cluster Disk Read Latency
2KB float Read Latency 2KB
38 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Cluster Disk Read Latency
32KB float Average read latency for 32KB block size.
Dell EMC XtremIO Cluster Disk Read Latency
4KB float Read Latency 4KB
Dell EMC XtremIO Cluster Disk Read Latency
512B float Read Latency 512B
Dell EMC XtremIO Cluster Disk Read Latency
512KB float Read Latency 512KB
Dell EMC XtremIO Cluster Disk Read Latency
64KB float Read Latency 64KB
Dell EMC XtremIO Cluster Disk Read Latency
8KB float Read Latency 8KB
Dell EMC XtremIO Cluster Disk
Read Latency Greater Than 1MB
float Read Latency Greater Than 1MB
Dell EMC XtremIO Cluster Disk Read Throughput float Read Throughput
Dell EMC XtremIO Cluster Disk Read Throughput
128KB float Read Throughput 128KB
Dell EMC XtremIO Cluster Disk Read Throughput
16KB float Read Throughput 16KB
Dell EMC XtremIO Cluster Disk Read Throughput
1KB float Read Throughput 1KB
Dell EMC XtremIO Cluster Disk Read Throughput
1MB float Read Throughput 1MB
Dell EMC XtremIO Cluster Disk Read Throughput
256KB float Read Throughput 256KB
Dell EMC XtremIO Cluster Disk Read Throughput
2KB float Read Throughput 2KB
Dell EMC XtremIO Cluster Disk Read Throughput
32KB float Read Throughput 32KB
Dell EMC XtremIO Cluster Disk Read Throughput
4KB float Read Throughput 4KB
Dell EMC XtremIO Cluster Disk Read Throughput
512B float Read Throughput 512B
Dell EMC XtremIO Cluster Disk Read Throughput
512KB float Read Throughput 512KB
Dell EMC XtremIO Cluster Disk Read Throughput
64KB float Read Throughput 64KB
Dell EMC XtremIO Cluster Disk Read Throughput
8KB float Read Throughput 8KB
Dell EMC XtremIO Cluster Disk Read Throughput
By Block float Read Throughput By Block
39 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Cluster Disk
Read Throughput Greater Than 1MB
float Read Throughput Greater Than 1MB
Dell EMC XtremIO Cluster Disk
SSD High Utilization Threshold Crossing
string SSD high utilization threshold crossing of the cluster.
Dell EMC XtremIO Cluster Disk
SSD Very High Utilization Threshold Crossing
string SSD very high utilization threshold crossing of the cluster.
Dell EMC XtremIO Cluster Disk Small IOPS float Small IOPS
Dell EMC XtremIO Cluster Disk Small Read IOPS float Small Read IOPS
Dell EMC XtremIO Cluster Disk Small Read
Throughput float Small Read Throughput
Dell EMC XtremIO Cluster Disk Small Throughput float Small Throughput
Dell EMC XtremIO Cluster Disk Small Write IOPS float Small Write IOPS
Dell EMC XtremIO Cluster Disk Small Write
Throughput float Small Write Throughput
Dell EMC XtremIO Cluster Disk Space In Use float Space in use by the cluster.
Dell EMC XtremIO Cluster Disk Space Saving
Ratio float The space saving ratio of the cluster.
Dell EMC XtremIO Cluster Disk Thin Provisioning
Ratio float The thin provisioning ratio of the cluster.
Dell EMC XtremIO Cluster Disk Thin Provisioning
Savings float Thin provisioning savings for the cluster.
Dell EMC XtremIO Cluster Disk Throughput float Throughput
Dell EMC XtremIO Cluster Disk Throughput
128KB float Throughput 128KB
Dell EMC XtremIO Cluster Disk Throughput 16KB float Throughput 16KB
Dell EMC XtremIO Cluster Disk Throughput 1KB float Throughput 1KB
Dell EMC XtremIO Cluster Disk Throughput 1MB float Throughput 1MB
Dell EMC XtremIO Cluster Disk Throughput
256KB float Throughput 256KB
Dell EMC XtremIO Cluster Disk Throughput 2KB float Throughput 2KB
40 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Cluster Disk Throughput 32KB float Throughput 32KB
Dell EMC XtremIO Cluster Disk Throughput 4KB float Throughput 4KB
Dell EMC XtremIO Cluster Disk Throughput 512B float Throughput 512B
Dell EMC XtremIO Cluster Disk Throughput
512KB float Throughput 512KB
Dell EMC XtremIO Cluster Disk Throughput 64KB float Throughput 64KB
Dell EMC XtremIO Cluster Disk Throughput 8KB float Throughput 8KB
Dell EMC XtremIO Cluster Disk Throughput By
Block float Throughput By Block
Dell EMC XtremIO Cluster Disk
Throughput Greater Than 1MB
float Throughput Greater Than 1MB
Dell EMC XtremIO Cluster Disk Unaligned IOPS float Unaligned IOPS
Dell EMC XtremIO Cluster Disk Unaligned Read
IOPS float Unaligned Read IOPS
Dell EMC XtremIO Cluster Disk Unaligned Read
Throughput float Unaligned Read Throughput
Dell EMC XtremIO Cluster Disk Unaligned
Throughput float Unaligned Throughput
Dell EMC XtremIO Cluster Disk Unaligned Write
IOPS float Unaligned Write IOPS
Dell EMC XtremIO Cluster Disk Unaligned Write
Throughput float Unaligned Write Throughput
Dell EMC XtremIO Cluster Disk Write IOPS float Write IOPS
Dell EMC XtremIO Cluster Disk Write IOPS 128KB float Write IOPS 128KB
Dell EMC XtremIO Cluster Disk Write IOPS 16KB float Write IOPS 16KB
Dell EMC XtremIO Cluster Disk Write IOPS 1KB float Write IOPS 1KB
Dell EMC XtremIO Cluster Disk Write IOPS 1MB float Write IOPS 1MB
Dell EMC XtremIO Cluster Disk Write IOPS 256KB float Write IOPS 256KB
Dell EMC XtremIO Cluster Disk Write IOPS 2KB float Write IOPS 2KB
Dell EMC XtremIO Cluster Disk Write IOPS 32KB float Write IOPS 32KB
41 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Cluster Disk Write IOPS 4KB float Write IOPS 4KB
Dell EMC XtremIO Cluster Disk Write IOPS 512B float Write IOPS 512B
Dell EMC XtremIO Cluster Disk Write IOPS 512KB float Write IOPS 512KB
Dell EMC XtremIO Cluster Disk Write IOPS 64KB float Write IOPS 64KB
Dell EMC XtremIO Cluster Disk Write IOPS 8KB float Write IOPS 8KB
Dell EMC XtremIO Cluster Disk Write IOPS By
Block float Write IOPS By Block
Dell EMC XtremIO Cluster Disk
Write IOPS Greater Than 1MB
float Write IOPS Greater Than 1MB
Dell EMC XtremIO Cluster Disk Write Latency float Write Latency
Dell EMC XtremIO Cluster Disk Write Latency
128KB float Write Latency 128KB
Dell EMC XtremIO Cluster Disk Write Latency
16KB float Write Latency 16KB
Dell EMC XtremIO Cluster Disk Write Latency
1KB float Write Latency 1KB
Dell EMC XtremIO Cluster Disk Write Latency
1MB float Write Latency 1MB
Dell EMC XtremIO Cluster Disk Write Latency
256KB float Write Latency 256KB
Dell EMC XtremIO Cluster Disk Write Latency
2KB float Write Latency 2KB
Dell EMC XtremIO Cluster Disk Write Latency
32KB float Write Latency 32KB
Dell EMC XtremIO Cluster Disk Write Latency
4KB float Write Latency 4KB
Dell EMC XtremIO Cluster Disk Write Latency
512B float Write Latency 512B
Dell EMC XtremIO Cluster Disk Write Latency
512KB float Write Latency 512KB
Dell EMC XtremIO Cluster Disk Write Latency
64KB float Write Latency 64KB
Dell EMC XtremIO Cluster Disk Write Latency
8KB float Write Latency 8KB
Dell EMC XtremIO Cluster Disk
Write Latency Greater Than 1MB
float Write Latency Greater Than 1MB
42 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Cluster Disk Write Throughput float Write Throughput
Dell EMC XtremIO Cluster Disk Write Throughput
128KB float Write throughput for 128KB block size.
Dell EMC XtremIO Cluster Disk Write Throughput
16KB float Write Throughput 16KB
Dell EMC XtremIO Cluster Disk Write Throughput
1KB float Write Throughput 1KB
Dell EMC XtremIO Cluster Disk Write Throughput
1MB float Write Throughput 1MB
Dell EMC XtremIO Cluster Disk Write Throughput
256KB float Write Throughput 256KB
Dell EMC XtremIO Cluster Disk Write Throughput
2KB float Write Throughput 2KB
Dell EMC XtremIO Cluster Disk Write Throughput
32KB float Write Throughput 32KB
Dell EMC XtremIO Cluster Disk Write Throughput
4KB float Write Throughput 4KB
Dell EMC XtremIO Cluster Disk Write Throughput
512B float Write throughput for 512B block size.
Dell EMC XtremIO Cluster Disk Write Throughput
512KB float Write throughput for 512KB block size.
Dell EMC XtremIO Cluster Disk Write Throughput
64KB float Write throughput for 64KB block size.
Dell EMC XtremIO Cluster Disk Write Throughput
8KB float Write Throughput 8KB
Dell EMC XtremIO Cluster Disk Write Throughput
By Block float Write Throughput By Block
Dell EMC XtremIO Cluster Disk
Write Throughput Greater Than 1MB
float Write Throughput Greater Than 1MB
Dell EMC XtremIO Cluster Memory Shared Memory float Shared memory of the cluster.
Dell EMC XtremIO Cluster Memory Shared Memory
In Use float Shared Memory In Use
Dell EMC XtremIO Cluster Memory Shared Memory
In Use Ratio Level string Shared memory in use ratio level of the cluster.
Dell EMC XtremIO Cluster Memory Total Memory In
Use float Total memory in use by the cluster.
Dell EMC XtremIO Cluster Memory Total Memory In
Use In Percent integer Percentage of total memory that is in use by the cluster.
Dell EMC XtremIO Cluster Network FC Port Speed string FC port speed.
Dell EMC XtremIO Cluster Status Cluster Expansion
In Progress string Whether or not a cluster expansion is in progress.
43 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Cluster Status Consistency State string Consistency state of the cluster.
Dell EMC XtremIO Cluster Status
Is Any C Module Lazy Load In Progress
string Whether or not any C module lazy load is in progress.
Dell EMC XtremIO Cluster Status
Is Any D Module Lazy Load In Progress
string Whether or not any D module lazy load is in progress.
Dell EMC XtremIO Cluster Status Memory Recovery
Status string Memory recovery status of the cluster.
Dell EMC XtremIO Cluster Status Mode Switch
Status string Status of the cluster mode switch.
Dell EMC XtremIO Cluster Status OS Upgrade In
Progress string Whether or not an OS upgrade is in progress on the cluster.
Dell EMC XtremIO Cluster Status Object Severity string Object severity.
Dell EMC XtremIO Cluster Status
Shared Memory In Use Recoverable Ratio Level
string Shared memory in use recoverable ratio level of the cluster.
Dell EMC XtremIO Cluster Status Stopped Reason string Reason for stoppage.
Dell EMC XtremIO Cluster Status System Health
State string Health state of the system.
Dell EMC XtremIO Cluster Status
System Manager Connection Error Reason
string Reason for the system manager connection error.
Dell EMC XtremIO Cluster Status System Manager
Connection State string State of the system manager connection.
Dell EMC XtremIO Cluster Status System State string State of the system.
Dell EMC XtremIO Cluster Status System Stop Type string System stop type of the cluster.
Dell EMC XtremIO Cluster Status Under
Maintenance string Whether or not the cluster is under maintenance.
Dell EMC XtremIO Cluster Status Upgrade Failure
Reason string Reason for the upgrade failure (if any).
Dell EMC XtremIO Cluster Status Upgrade State string Upgrade state of the cluster.
Dell EMC XtremIO Cluster Status
VAAI Thin Provisioning Limit Crossing
string VAAI thin provisioning limit crossing of the cluster.
Dell EMC XtremIO Cluster
User Configuration Encryption Mode string
Controls whether encryption (Data at Rest) is performed for all cluster SSDs, DAE SSDs and Local Disks.
44 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Cluster
User Configuration Obfuscate Debug string
Determines whether debug information is created while obfuscating IP addresses. Default is disabled. Debug information is placed in the log bundle.
Dell EMC XtremIO Cluster
User Configuration
SC Front Panel Temperature Monitor Mode
stringStorage Controller front panel temperature monitor mode (the parameter used to disable the feature if the front panel sensor is faulty).
Dell EMC XtremIO Cluster
User Configuration
SSH Firewall Mode string SSH Firewall Mode
Dell EMC XtremIO Cluster Relationships Dell EMC XtremIO
Tag Parents string List of parent Dell EMC XtremIO Tag resources
Dell EMC XtremIO Cluster Relationships InfiniBand Switch
Children string List of child InfiniBand Switch resources
Dell EMC XtremIO Cluster Relationships Volume Children string List of child Volume resources
Dell EMC XtremIO Cluster Relationships X-Brick Children string List of child X-Brick resources
Dell EMC XtremIO Cluster Relationships
XtremIO Management Server Parents
string List of parent XtremIO Management Server resources
Dell EMC XtremIO Data Protection Group
Details Available Rebuilds float Number of available rebuilds the DPG can currently perform.
Dell EMC XtremIO Data Protection Group
Details Index integerDPG's index number as defined by the XMS upon its creation (a unique positive number).
Dell EMC XtremIO Data Protection Group
Details Integrating Slot Number integer
Slot currently undergoing processing. The value is 0 when no specific Slot is undergoing processing.
Dell EMC XtremIO Data Protection Group
Details Node Count integer DPG's total number of Storage Controllers.
Dell EMC XtremIO Data Protection Group
Details Proactive Metadata Loading string
This Boolean property reflects whether the cluster performs proactive loading of the metadata (property returns true). This may happen after the cluster is started or recovers from an extreme situation. At this stage, there may be performance degradation.
Dell EMC XtremIO Data Protection Group
Details SSD Count integer DPG's total number of the SSDs.
Dell EMC XtremIO Data Protection Group
Disk IOPS float IOPS
Dell EMC XtremIO Data Protection Group
DiskMaximum Observation of IOPS
integer Maximum observed value of metric IOPS.
45 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Data Protection Group
DiskMaximum Observation of Throughput
float Maximum observed value of metric Throughput.
Dell EMC XtremIO Data Protection Group
Disk Physical Percent Free Space integer DPG's percentage of free physical
space.
Dell EMC XtremIO Data Protection Group
Disk Physical Space float Total physical space on the SSDs.
Dell EMC XtremIO Data Protection Group
Disk Physical Space In Use float Reports how much of physical space
of the DPG is currently in use.
Dell EMC XtremIO Data Protection Group
Disk Physical Space In Use float Physical space in use.
Dell EMC XtremIO Data Protection Group
Disk Physical Space Levels string
DPG physical space levels. Events are triggered for any change in this parameter.
Dell EMC XtremIO Data Protection Group
Disk Read / Write Ratio float The ratio of read to write IOPS.
Dell EMC XtremIO Data Protection Group
Disk Read IOPS float Read IOPS.
Dell EMC XtremIO Data Protection Group
Disk Read IOPS 128KB float Read IOPS for 128KB reads.
Dell EMC XtremIO Data Protection Group
Disk Read IOPS 16KB float Read IOPS for 16KB reads.
Dell EMC XtremIO Data Protection Group
Disk Read IOPS 1KB float Read IOPS for 1KB reads.
Dell EMC XtremIO Data Protection Group
Disk Read IOPS 1MB float Read IOPS for 1MB reads.
Dell EMC XtremIO Data Protection Group
Disk Read IOPS 256KB float Read IOPS for 256KB reads.
Dell EMC XtremIO Data Protection Group
Disk Read IOPS 2KB float Read IOPS for 2KB reads.
Dell EMC XtremIO Data Protection Group
Disk Read IOPS 32KB float Read IOPS for 32KB reads.
Dell EMC XtremIO Data Protection Group
Disk Read IOPS 4KB float Read IOPS for 4KB reads.
46 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Data Protection Group
Disk Read IOPS 512B float Read IOPS for 512B reads.
Dell EMC XtremIO Data Protection Group
Disk Read IOPS 512KB float Read IOPS for 512KB reads.
Dell EMC XtremIO Data Protection Group
Disk Read IOPS 64KB float Read IOPS for 64KB reads.
Dell EMC XtremIO Data Protection Group
Disk Read IOPS 8KB float Read IOPS for 8KB reads.
Dell EMC XtremIO Data Protection Group
Disk Read IOPS By Block float Read IOPS for block reads.
Dell EMC XtremIO Data Protection Group
DiskRead IOPS Greater Than 1MB
float Read IOPS for reads greater than one megabyte.
Dell EMC XtremIO Data Protection Group
Disk Read Throughput float Read Throughput
Dell EMC XtremIO Data Protection Group
Disk Read Throughput 128KB float Read throughput for 128KB reads.
Dell EMC XtremIO Data Protection Group
Disk Read Throughput 16KB float Read throughput for 16KB reads.
Dell EMC XtremIO Data Protection Group
Disk Read Throughput 1KB float Read throughput for 1KB reads.
Dell EMC XtremIO Data Protection Group
Disk Read Throughput 1MB float Read throughput for 1MB reads.
Dell EMC XtremIO Data Protection Group
Disk Read Throughput 256KB float Read throughput for 256KB reads.
Dell EMC XtremIO Data Protection Group
Disk Read Throughput 2KB float Read throughput for 2KB reads.
Dell EMC XtremIO Data Protection Group
Disk Read Throughput 32KB float Read throughput for 32KB reads.
Dell EMC XtremIO Data Protection Group
Disk Read Throughput 4KB float Read throughput for 4KB reads.
Dell EMC XtremIO Data Protection Group
Disk Read Throughput 512B float Read throughput for 512B reads.
47 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Data Protection Group
Disk Read Throughput 512KB float Read throughput for 512KB reads.
Dell EMC XtremIO Data Protection Group
Disk Read Throughput 64KB float Read throughput for 64KB reads.
Dell EMC XtremIO Data Protection Group
Disk Read Throughput 8KB float Read throughput for 8KB reads.
Dell EMC XtremIO Data Protection Group
Disk Read Throughput By Block float Read throughput for block reads.
Dell EMC XtremIO Data Protection Group
DiskRead Throughput Greater Than 1MB
float Read throughput for reads greater than a megabyte.
Dell EMC XtremIO Data Protection Group
Disk SSD Preparation Progress integer
Indicates if the DPG is currently performing an SSD preparation, and its progress.
Dell EMC XtremIO Data Protection Group
Disk SSD Size float DPG's overall size of unfailed SSDs.
Dell EMC XtremIO Data Protection Group
Disk Throughput float Total Throughput(read + write)
Dell EMC XtremIO Data Protection Group
Disk Useful SSD Space float
DPG's total amount of useful SSD space over all unfailed SSDs, for this DPG.
Dell EMC XtremIO Data Protection Group
Disk Write IOPS float Write IOPS.
Dell EMC XtremIO Data Protection Group
Disk Write IOPS 128KB float Write IOPS for 128KB writes.
Dell EMC XtremIO Data Protection Group
Disk Write IOPS 16KB float Write IOPS for 16KB writes.
Dell EMC XtremIO Data Protection Group
Disk Write IOPS 1KB float Write IOPS for 1KB writes.
Dell EMC XtremIO Data Protection Group
Disk Write IOPS 1MB float Write IOPS for 1MB writes.
Dell EMC XtremIO Data Protection Group
Disk Write IOPS 256KB float Write IOPS for 256KB writes.
Dell EMC XtremIO Data Protection Group
Disk Write IOPS 2KB float Write IOPS for 2KB writes.
48 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Data Protection Group
Disk Write IOPS 32KB float Write IOPS for 32KB writes.
Dell EMC XtremIO Data Protection Group
Disk Write IOPS 4KB float Write IOPS for 4KB writes.
Dell EMC XtremIO Data Protection Group
Disk Write IOPS 512B float Write IOPS for 512B writes.
Dell EMC XtremIO Data Protection Group
Disk Write IOPS 512KB float Write IOPS for 512KB writes.
Dell EMC XtremIO Data Protection Group
Disk Write IOPS 64KB float Write IOPS for 64KB writes.
Dell EMC XtremIO Data Protection Group
Disk Write IOPS 8KB float Write IOPS for 8KB writes.
Dell EMC XtremIO Data Protection Group
Disk Write IOPS By Block float Write IOPS for block writes.
Dell EMC XtremIO Data Protection Group
DiskWrite IOPS Greater Than 1MB
float Write IOPS for writes greater than one megabyte.
Dell EMC XtremIO Data Protection Group
Disk Write Throughput float Write throughput.
Dell EMC XtremIO Data Protection Group
Disk Write Throughput 128KB float Write throughput for 128KB writes.
Dell EMC XtremIO Data Protection Group
Disk Write Throughput 16KB float Write throughput for 16KB writes.
Dell EMC XtremIO Data Protection Group
Disk Write Throughput 1KB float Write throughput for 1KB writes.
Dell EMC XtremIO Data Protection Group
Disk Write Throughput 1MB float Write throughput for 1MB writes.
Dell EMC XtremIO Data Protection Group
Disk Write Throughput 256KB float Write throughput for 256KB writes.
Dell EMC XtremIO Data Protection Group
Disk Write Throughput 2KB float Write throughput for 2KB writes.
Dell EMC XtremIO Data Protection Group
Disk Write Throughput 32KB float Write throughput for 32KB writes.
49 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Data Protection Group
Disk Write Throughput 4KB float Write throughput for 4KB writes.
Dell EMC XtremIO Data Protection Group
Disk Write Throughput 512B float Write throughput for 512B writes.
Dell EMC XtremIO Data Protection Group
Disk Write Throughput 512KB float Write throughput for 512KB writes.
Dell EMC XtremIO Data Protection Group
Disk Write Throughput 64KB float Write throughput for 64KB writes.
Dell EMC XtremIO Data Protection Group
Disk Write Throughput 8KB float Write throughput for 8KB writes.
Dell EMC XtremIO Data Protection Group
Disk Write Throughput By Block float Write throughput for block writes.
Dell EMC XtremIO Data Protection Group
DiskWrite Throughput Greater Than 1MB
float Write throughput for writes greater than one megabyte.
Dell EMC XtremIO Data Protection Group
Status Object Severity string
DPG's severity, based on severity level of current Alerts (Alerts still uncleared) for this DPG. Possible values are 'clear', 'information', 'minor', 'major', or 'critical'.
Dell EMC XtremIO Data Protection Group
Status Protection State stringDPG's protection state. If the DPG is currently under initial configuration, the parameter is initializing.
Dell EMC XtremIO Data Protection Group
Status Rebalance Progress integer Shows the progress of a DPG
rebalance.
Dell EMC XtremIO Data Protection Group
Status Rebuild In Progress string Indicates if the DPG currently performs
a rebuild, and its progress.
Dell EMC XtremIO Data Protection Group
StatusRebuild Prevention Reason
string
When an DPG enters a degraded state (either single or dual failure), a rebuild is generally initiated. However, conditions may prevent the rebuild. The parameter includes the reason for rebuild prevention.
Dell EMC XtremIO Data Protection Group
Status Rebuild Progress integer The rebuild progress status.
Dell EMC XtremIO Data Protection Group
Status SSD Preparation In Progress string The current state of the SSD
preparation.
Dell EMC XtremIO Data Protection Group
Relationships SSD Children string List of child SSD resources
50 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Data Protection Group
Relationships X-Brick Parents string List of parent X-Brick resources
Dell EMC XtremIO Disk Array Enclosure Details DAE Controller
Count integer Number of DAE controllers.
Dell EMC XtremIO Disk Array Enclosure Details DAE PSU Count integer Number of DAE PSUs.
Dell EMC XtremIO Disk Array Enclosure Details Firmware Version string Firmware version of the disk array
enclosure.
Dell EMC XtremIO Disk Array Enclosure Details Hardware
Revision string Hardware revision of the disk array enclosure.
Dell EMC XtremIO Disk Array Enclosure Details Index integer Index of the disk array enclosure.
Dell EMC XtremIO Disk Array Enclosure Details Model Name string Model name of the disk array
enclosure.
Dell EMC XtremIO Disk Array Enclosure Details Part Number string Part Number
Dell EMC XtremIO Disk Array Enclosure Details Serial Number string Serial Number
Dell EMC XtremIO Disk Array Enclosure Status FRU Lifecycle
State string FRU lifecycle state of the disk array enclosure.
Dell EMC XtremIO Disk Array Enclosure Status FRU Replace
Failure Reason string Reason (if any) for the FRU replace failure.
Dell EMC XtremIO Disk Array Enclosure Status Identify LED string Identify LED of the disk array
enclosure.
Dell EMC XtremIO Disk Array Enclosure Status Object Severity string Object severity of the disk array
enclosure.
Dell EMC XtremIO Disk Array Enclosure Status Status LED string Status LED for the disk array
enclosure.
Dell EMC XtremIO Disk Array Enclosure Relationships PSU Children string List of child PSU resources
Dell EMC XtremIO Disk Array Enclosure Relationships SSD Children string List of child SSD resources
Dell EMC XtremIO Disk Array Enclosure Relationships X-Brick Parents string List of parent X-Brick resources
Dell EMC XtremIO Host Interface Details Certainty string
Indicates confidence that the XMS and the cluster are synchronized. Value changes from OK if a request is sent but the XMS is unable to determine the success of the request.
Dell EMC XtremIO Host Interface Details Driver Version string Driver version of the Target object.
Dell EMC XtremIO Host Interface Details Fibre Channel
Dumped Frames floatThe Fibre Channel ports' diagnostic counter for dumped frames. Impacts the port_health_level.
51 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Host Interface Details
Fibre Channel Invalid CRC Count
floatThe Fibre Channel ports' diagnostic counter for invalid CRC count. Impacts the port_health_level.
Dell EMC XtremIO Host Interface Details Fibre Channel
Link Failure Count floatThe Fibre Channel ports' diagnostic counter for failure count. Impacts the port_health_level.
Dell EMC XtremIO Host Interface Details
Fibre Channel Loss of Signal Count
floatThe Fibre Channel ports' diagnostic counter for loss of signal count. Impacts the port_health_level.
Dell EMC XtremIO Host Interface Details
Fibre Channel Loss of Sync Count
floatThe Fibre Channel ports' diagnostic counter for loss of synchronized count. Impacts the port_health_level.
Dell EMC XtremIO Host Interface Details
Fibre Channel Primary Sequential Protocol Error Count
floatThe Fibre Channel ports' diagnostic counter for primary sequential protocol error count. Impacts the port-health-level.
Dell EMC XtremIO Host Interface Details
Fibre Channel Sequential Retransmitted Request Count
floatThe Fibre Channel ports' diagnostic counter for sequential retransmission request count. Values impact the port_health_level.
Dell EMC XtremIO Host Interface Details Firmware Version string Current firmware version of the Target.
Dell EMC XtremIO Host Interface Details Index integer Index
Dell EMC XtremIO Host Interface Details MTU float
Maximum valid values for maximum transmission unit sizes are 1500 when non-jumbo frames are enabled and 9216 when jumbo frames are enabled for iSCSI Targets. Applicable for iSCSI only.
Dell EMC XtremIO Host Interface Details Port Address string Port Address
Dell EMC XtremIO Host Interface Details Port Index integer Port Index
Dell EMC XtremIO Host Interface Details Port MAC
Address string MAC address of this target port (relevant for iSCSI Targets only).
Dell EMC XtremIO Host Interface Details Port Type string Port type (Fibre Channel or iSCSI) and
port's address.
Dell EMC XtremIO Host Interface Details Relative Target
Port float Indicates the relative Target port.
Dell EMC XtremIO Host Interface Disk
Accumulated Read Operation Count
floatTotal accumulative number of read operations having occurred during the Target's lifespan.
Dell EMC XtremIO Host Interface Disk
Accumulated Size of Read Operation Count
floatAccumulative capacity KB size of read operations having occurred during the Target's lifespan.
52 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Host Interface Disk
Accumulated Size of Write Operation Count
floatAccumulative capacity KB size of write operations having occurred during the Target's lifespan.
Dell EMC XtremIO Host Interface Disk
Accumulated Small Read IO Operation Count
float Accumulated number small reads input/output operations for the Target.
Dell EMC XtremIO Host Interface Disk
Accumulated Small Write IO Operation Count
floatAccumulated number of small writes input/output operations recursively held by this Target.
Dell EMC XtremIO Host Interface Disk
Accumulated Unaligned Read IO Operation Count
floatAccumulated number of unaligned reads for input/output operations recursively contained by this Target.
Dell EMC XtremIO Host Interface Disk
Accumulated Unaligned Write IO Operation Count
floatAccumulated number of unaligned writes for input/output operations recursively contained by this Target.
Dell EMC XtremIO Host Interface Disk
Accumulated Write Operation Count
floatAccumulative number of write operations having occurred during the Target's lifespan.
Dell EMC XtremIO Host Interface Disk Average Latency float Average latency of read and write
operations.
Dell EMC XtremIO Host Interface Disk IOPS float Target's total read and write real-time
input/output operations per second.
Dell EMC XtremIO Host Interface Disk
Maximum Observed Throughput
float Maximum observed value of metric Maximum Observed Throughput.
Dell EMC XtremIO Host Interface Disk
Maximum Observed Total IOPS
float Maximum observed value of metric Maximum Observed Total IOPS.
Dell EMC XtremIO Host Interface Disk Read / Write Ratio float The ratio of read to write IOPS.
Dell EMC XtremIO Host Interface Disk Read IOPS float Total read real-time input/output
operations per second.
Dell EMC XtremIO Host Interface Disk Read Latency float Real-time average latency of read
operations.
Dell EMC XtremIO Host Interface Disk Read Throughput float Total read bandwidth in MB per
second.
Dell EMC XtremIO Host Interface Disk Small IOPS float
Current IOPS of small input/output operations per second, addressed at the Initiator Group.
Dell EMC XtremIO Host Interface Disk Small Read IOPS float
Current IOPS of small read input/output operations per second, addressed at the Target.
Dell EMC XtremIO Host Interface Disk Small Read
Throughput floatCurrent bandwidth of small input/output operations, addressed at the Target.
53 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Host Interface Disk Small Throughput float
Current bandwidth of small input/output operations, addressed at the Target.
Dell EMC XtremIO Host Interface Disk Small Write IOPS float
Current IOPS of small write input/output operations per second, addressed at the Target.
Dell EMC XtremIO Host Interface Disk Small Write
Throughput floatCurrent bandwidth of small write input/output operations, addressed at the Target.
Dell EMC XtremIO Host Interface Disk Throughput float Total read and write bandwidth.
Dell EMC XtremIO Host Interface Disk Unaligned IOPS float
Current IOPS of unaligned input/output operations per second, addressed at the Target.
Dell EMC XtremIO Host Interface Disk Unaligned Read
IOPS floatCurrent IOPS of unaligned read input/output operations per second, addressed at the Target.
Dell EMC XtremIO Host Interface Disk Unaligned Read
Throughput floatCurrent bandwidth of unaligned input/output operations, addressed at the Target.
Dell EMC XtremIO Host Interface Disk Unaligned
Throughput floatCurrent bandwidth of unaligned input/output operations, addressed at the Target.
Dell EMC XtremIO Host Interface Disk Unaligned Write
IOPS floatCurrent IOPS of unaligned write input/output operations per second, addressed at the Target.
Dell EMC XtremIO Host Interface Disk Unaligned Write
Throughput floatCurrent bandwidth of unaligned write input/output operation, addressed at the Target.
Dell EMC XtremIO Host Interface Disk Write IOPS float Total write real-time input/output
operations per second.
Dell EMC XtremIO Host Interface Disk Write Latency float Real-time average latency of write
operations.
Dell EMC XtremIO Host Interface Disk Write Throughput float Total write bandwidth in MB per
second
Dell EMC XtremIO Host Interface Network Ethernet Kbytes
Received float The total KBS received. Relevant for iSCSI only.
Dell EMC XtremIO Host Interface Network Ethernet Kbytes
Transmitted float The total number of KBS transmitted. Relevant for iSCSI only.
Dell EMC XtremIO Host Interface Network Ethernet Packet
Received float The number of Ethernet packets received. Relevant for iSCSI only.
Dell EMC XtremIO Host Interface Network Ethernet Packets
Transmitted float The number of Ethernet packets transmitted. Relevant for iSCSI only.
Dell EMC XtremIO Host Interface Network Jumbo Enabled string
Determines whether jumbo frames are supported for this Target. The default value is false.
54 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Host Interface Network Port Speed string
The negotiated speed of the port (some applicable for Ethernet and some for Fibre Channel).
Dell EMC XtremIO Host Interface Network
Total CRC Error Ethernet Packets Received
floatThe number of Ethernet frames received with CRC error (and thus dropped). Relevant for iSCSI only.
Dell EMC XtremIO Host Interface Network Total Dropped
Ethernet Packets floatThe number of packets that failed to be transmitted due to error. Relevant for iSCSI only.
Dell EMC XtremIO Host Interface Network
Total No Buffer Error Ethernet Packets Received
floatThe number of Ethernet packets that failed to be received due to lack of buffer space. Relevant for iSCSI only.
Dell EMC XtremIO Host Interface Status Object Severity string
Target's severity, based on severity level of current Alerts (Alerts still uncleared) for this Target.
Dell EMC XtremIO Host Interface Status Port Health Level string Port Health Level
Dell EMC XtremIO Host Interface Status Port State string State of the Target port (Fibre Channel
or iSCSI).
Dell EMC XtremIO Host Interface Status Tar Error Reason string Failure type causing the Target's
target_health_state not to be 'clear'.
Dell EMC XtremIO Host Interface Relationships Storage Controller
Parents string List of parent Storage Controller resources
Dell EMC XtremIO InfiniBand Switch Details 2.5V in Sensor
Voltage float The voltage of the 3.3V SX voltage sensor.
Dell EMC XtremIO InfiniBand Switch Details 5v Sensor Voltage float The voltage of the 1.8V voltage sensor.
Dell EMC XtremIO InfiniBand Switch Details ADM1024 Sensor
Temperature integer The temperature of the internal sensor closest to the heat-sink.
Dell EMC XtremIO InfiniBand Switch Details ADM1191 Sensor
Voltage float The voltage of the 12v voltage sensor.
Dell EMC XtremIO InfiniBand Switch Details Fan 1 Speed float The speed of fan 1.
Dell EMC XtremIO InfiniBand Switch Details Fan 2 Speed float The speed of fan 2.
Dell EMC XtremIO InfiniBand Switch Details Fan 3 Speed float The speed of fan 3.
Dell EMC XtremIO InfiniBand Switch Details Fan 4 Speed float The speed of fan 4.
Dell EMC XtremIO InfiniBand Switch Details Firmware PSID string Internal ID of the firmware.
Dell EMC XtremIO InfiniBand Switch Details Firmware Version string Current firmware version of the
InfiniBand Switch.
Dell EMC XtremIO InfiniBand Switch Details Hardware
Revision string Hardware level of the InfiniBand Switch.
55 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO InfiniBand Switch Details Index integer
The InfiniBand Switch's index number as defined by the XMS upon its creation (a unique positive number).
Dell EMC XtremIO InfiniBand Switch Details
LM75 Center Sensor Temperature
integerThe temperature of the center temperature sensor close to QSFP cages.
Dell EMC XtremIO InfiniBand Switch Details LM75 Left Sensor
Temperature integerThe temperature of the left temperature sensor close to QSFP cages.
Dell EMC XtremIO InfiniBand Switch Details
LM75 Right Sensor Temperature
integerThe temperature of the right temperature sensor close to QSFP cages.
Dell EMC XtremIO InfiniBand Switch Details Part Number string
EMC-assigned string identifying part (SKU), independent of the actual vendor model_name used for this FRU.
Dell EMC XtremIO InfiniBand Switch Details Port Count integer Total number of ports in the InfiniBand
Switch.
Dell EMC XtremIO InfiniBand Switch Details
SX Internal Sensor Temperature
integer The temperature of the SwitchX Silicon internal sensor.
Dell EMC XtremIO InfiniBand Switch Details Serial Number string The serial number of the InfiniBand
Switch.
Dell EMC XtremIO InfiniBand Switch Details Temperature
Sensor Count integer Total number of temperature sensors.
Dell EMC XtremIO InfiniBand Switch Details VCC Sensor
Voltage float The voltage of the VCC voltage sensor.
Dell EMC XtremIO InfiniBand Switch Details VCCP1 Sensor
Voltage float The voltage of the V-Core voltage sensor.
Dell EMC XtremIO InfiniBand Switch Details VCCP2 Sensor
Voltage float The voltage of the 1.2V voltage sensor.
Dell EMC XtremIO InfiniBand Switch Details Voltage Sensor
Count integer Total number of voltage sensors.
Dell EMC XtremIO InfiniBand Switch Status Enabled State string
Indicates whether the InfiniBand Switch is currently enabled or disabled, either by the user or the cluster.
Dell EMC XtremIO InfiniBand Switch Status FRU Lifecycle
State string
The FRU state of the InfiniBand Switch, using the generic FRU transition states. Possible values are 'healthy', 'failed', 'disconnected', 'uninitialized', and 'initializing'.
Dell EMC XtremIO InfiniBand Switch Status FRU Replace
Failure Reason string
Reason why the FRU replacement has failed. 'null' means that the last FRU replacement was either not performed for this object or the replacement was successful.
56 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO InfiniBand Switch Status Fan Drawer
Status string
The fan drawer status, based on the speed of each fan. The fan drawer comprises of four fans. Possible values include 'health', 'one_fan_failed', and 'failed'.
Dell EMC XtremIO InfiniBand Switch Status Firmware Version
Error string
Used to indicate if the firmware or OS upgrade has failed or is in the process of upgrading. This reflects the aggregate of all Storage Controller OS and firmware upgrades.
Dell EMC XtremIO InfiniBand Switch Status Identify LED string
Indicates whether the identification LED is illuminated for this InfiniBand Switch. The property value is reflected in the GUI LED icon. Note: There is no identification LED in the current PSU. Possible values are 'off', 'blinking', 'on', and 'na'.
Dell EMC XtremIO InfiniBand Switch Status Inter Switch IB 1
Port State stringThe status of the first InfiniBand port used to connect to the other InfiniBand Switch.
Dell EMC XtremIO InfiniBand Switch Status Inter Switch IB 2
Port State stringThe status of the second InfiniBand port used to connect to the other InfiniBand Switch.
Dell EMC XtremIO InfiniBand Switch Status Is Available string The InfiniBand Switch's availability
status in relation to the system.
Dell EMC XtremIO InfiniBand Switch Status Object Severity string
InfiniBand Switch's severity, based on severity level of current Alerts (Alerts still uncleared) for this resource and its contained objects. Possible values are 'clear', 'information', 'minor', 'major', and 'critical'.
Dell EMC XtremIO InfiniBand Switch Status Status LED string LED state indicating the InfiniBand
Switch's object faults.
Dell EMC XtremIO InfiniBand Switch Status
Wrong SC Connection Detected
stringDenotes if at least one Storage Controller is not connected to the corresponding InfiniBand Switch port.
Dell EMC XtremIO InfiniBand Switch Relationships Cluster Parents string List of parent Cluster resources
Dell EMC XtremIO InfiniBand Switch Relationships Storage Controller
Parents string List of parent Storage Controller resources
Dell EMC XtremIO Local Disk Details Bad Sector Count integer Number of bad sectors on the local
disk.
Dell EMC XtremIO Local Disk Details Firmware Version string Firmware version of the local disk.
Dell EMC XtremIO Local Disk Details Hardware
Revision string Hardware Revision
Dell EMC XtremIO Local Disk Details Index integer Index of the local disk.
57 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Local Disk Details Local Disk
Expected Type string Local Disk Expected Type
Dell EMC XtremIO Local Disk Details Local Disk
Purpose string Purpose of the local disk.
Dell EMC XtremIO Local Disk Details Local Disk Type string Local disk type.
Dell EMC XtremIO Local Disk Details Local Disk UID string UID of the local disk.
Dell EMC XtremIO Local Disk Details Model Name string Model Name
Dell EMC XtremIO Local Disk Details Part Number string Part number of the local disk.
Dell EMC XtremIO Local Disk Details Slot Number integer Slot number of the local disk.
Dell EMC XtremIO Local Disk Status Disk Failure string Disk failure status of the local disk.
Dell EMC XtremIO Local Disk Status Enabled State string Enabled state of the local disk.
Dell EMC XtremIO Local Disk Status Encryption Status string Encryption status of the local disk.
Dell EMC XtremIO Local Disk Status FRU Lifecycle
State string FRU lifecycle state of the local disk.
Dell EMC XtremIO Local Disk Status FRU Replace
Failure Reason string Reason (if any) for the FRU replacement failure.
Dell EMC XtremIO Local Disk Status Firmware Version
Error string Firmware version error of the local disk.
Dell EMC XtremIO Local Disk Status Identify LED string Identify LED of the local disk.
Dell EMC XtremIO Local Disk Status Object Severity string Object severity of the local disk.
Dell EMC XtremIO Local Disk Status Status LED string Status LED of the local disk.
Dell EMC XtremIO Local Disk Relationships Storage Controller
Parents string List of parent Storage Controller resources
Dell EMC XtremIO PSU Details DAE GUID string GUID of the PSU's DAE.
Dell EMC XtremIO PSU Details Firmware Version string Firmware Version
Dell EMC XtremIO PSU Details Hardware
Revision string Hardware Revision
Dell EMC XtremIO PSU Details Identification string Identification
Dell EMC XtremIO PSU Details Index integer Index
58 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO PSU Details Input string Input
Dell EMC XtremIO PSU Details Location string Location
Dell EMC XtremIO PSU Details Model Name string Model Name
Dell EMC XtremIO PSU Details Part Number string Part Number
Dell EMC XtremIO PSU Details Power Feed string Power Feed
Dell EMC XtremIO PSU Details Serial Number string Serial Number
Dell EMC XtremIO PSU Details Storage Controller
GUID string GUID of the PSU's Storage Controller.
Dell EMC XtremIO PSU Status Enabled State string Enabled State
Dell EMC XtremIO PSU Status FRU Lifecycle
State string FRU Lifecycle State
Dell EMC XtremIO PSU Status FRU Replace
Failure Reason string FRU Replace Failure Reason
Dell EMC XtremIO PSU Status Firmware Version
Error string Firmware Version Error
Dell EMC XtremIO PSU Status Identify LED string Identify LED
Dell EMC XtremIO PSU Status Object Severity string Object Severity
Dell EMC XtremIO PSU Status Power Failure string Power Failure
Dell EMC XtremIO PSU Status Status LED string Status LED of the PSU.
Dell EMC XtremIO PSU Relationships Disk Array
Enclosure Parents string List of parent Disk Array Enclosure resources
Dell EMC XtremIO PSU Relationships Storage Controller
Parents string List of parent Storage Controller resources
Dell EMC XtremIO Snapshot Details Alignment Offset integer The alignment offset range is between
0-15.
Dell EMC XtremIO Snapshot Details Certainty string
Indicates confidence that the XMS and the cluster are synchronized. Value changes from OK if a request is sent while the XMS is unable to determine the success of the request.
59 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Snapshot Details Created From
Volume string
This parameter contains the snapped_object Volume name, as it was at the Snapshot's creation time, or null when the Volume was not created from a Snapshot. The string remains unchanged when the ancestor is renamed, deleted or reassigned.
Dell EMC XtremIO Snapshot Details Creation Time string Snapshot's creation timestamp.
Dell EMC XtremIO Snapshot Details Destination
Snapshot Count float Number of Snapshots directly Snapshotted from this Snapshot.
Dell EMC XtremIO Snapshot Details Index integer
Snapshot's index number as defined by the XMS upon its creation (a unique positive number).
Dell EMC XtremIO Snapshot Details LUN Mapping
Count float Number of LUN mappings defined for this Snapshot.
Dell EMC XtremIO Snapshot Details Lb Size float The 'sector size' (LB size) of the
Snapshot.
Dell EMC XtremIO Snapshot Details NAA Name string
Snapshot's WWN/NAA name, globally unique and unique over time, set by the XMS (or by cluster) once a LUN is mapped to the Snapshot for the first time.
Dell EMC XtremIO Snapshot Details Small IO Alerts string
When Volume parameter of small_io_alerts is set to 'disabled' (default), no Alerts are sent for a high number of small I/Os.
Dell EMC XtremIO Snapshot Details Snapshot Type string A Snapshot is regular (default) or
readonly.
Dell EMC XtremIO Snapshot Details Unaligned IO
Alerts stringWhen this Snapshot parameter is set to disabled (default), no Alerts are sent for high numbers of unaligned.
Dell EMC XtremIO Snapshot Details
VAAI Thin Provisioning Alerts
string
The VAAI Soft Limit warning for this Volume is reported when monitoring is enabled. The threshold is a cluster-wide value as configured in the cluster vaai_tp_limit. The default is disabled.
Dell EMC XtremIO Snapshot Details Volume Access string
Denotes the host access configuration. Possible values are 'no_access', 'read_access', or 'writes_access'.
Dell EMC XtremIO Snapshot Details Volume ID integer
Snapshot's index number as defined by the XMS upon its creation (a unique positive number).
Dell EMC XtremIO Snapshot Details Volume Size float Total provisioned capacity. Snapshot
KB size as exposed to Initiators.
Dell EMC XtremIO Snapshot Details Volume Snapshot
Group Index integer The Volume Snapshot Group (VSG) Index.
60 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Snapshot Details
Volume Snapshot Source Index Number
integer
Holds the Volume Snapshot source index number for the Snapshot. This parameter points to an object from which the Snapshot was created, providing that the 'ancestor' object is not deleted, or that create-snapshot-and-reassign was not applied.
Dell EMC XtremIO Snapshot Details Volume Type string Denotes the Volume type. Possible
values are 'regular' or 'readonly'.
Dell EMC XtremIO Snapshot Disk
Accumulated Read Operation Count
floatTotal accumulative number of read operations having occurred during the Volume's lifespan.
Dell EMC XtremIO Snapshot Disk Accumulated Size
of Read floatAccumulative capacity KB size of read operations having occurred during the Snapshot's lifespan.
Dell EMC XtremIO Snapshot Disk Accumulated Size
of Write floatAccumulative capacity size of write operations having occurred during the Snapshot's lifespan.
Dell EMC XtremIO Snapshot Disk
Accumulated Small Read Operation Count
floatAccumulated number of small reads input/output operations for the Snapshot.
Dell EMC XtremIO Snapshot Disk
Accumulated Small Write Operation Count
floatAccumulated number of small writes input/output operations recursively contained by this Snapshot
Dell EMC XtremIO Snapshot Disk
Accumulated Unaligned Read Operation Count
float Snapshot's accumulated number of I/Os since adding the Initiator.
Dell EMC XtremIO Snapshot Disk
Accumulated Unaligned Write Operation Count
float Cluster's total number of accumulated unaligned writes.
Dell EMC XtremIO Snapshot Disk
Accumulated Write Operation Count
floatAccumulative number of write operations having occurred during the Snapshot's lifespan.
Dell EMC XtremIO Snapshot Disk Average Latency float Total real-time average latency of read
and write operations.
Dell EMC XtremIO Snapshot Disk IOPS float
Snapshot 's total read and write real-time input/output operations per second.
Dell EMC XtremIO Snapshot Disk Logical Space In
Use floatThe total used Volume/ Snapshot capacity in all clusters managed by the XMS.
Dell EMC XtremIO Snapshot Disk Read IOPS float Total read real-time input/output
operations per second.
Dell EMC XtremIO Snapshot Disk Read Latency float Total real-time average latency of read
operations.
Dell EMC XtremIO Snapshot Disk Read Throughput float Total real-time read bandwidth in MB
per second.
61 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Snapshot Disk Small IO Ratio float
The accumulated number of unaligned I/O divided by the total accumulated number of I/Os to the Snapshot.
Dell EMC XtremIO Snapshot Disk Small IO Ratio
Level string Event triggered whenever the unaligned-io-ratio level changes.
Dell EMC XtremIO Snapshot Disk Small IOPS float Current IOPS of small input/output
operations per second.
Dell EMC XtremIO Snapshot Disk Small Read IOPS float Current IOPS of small read input/
output operations per second.
Dell EMC XtremIO Snapshot Disk Small Read
Throughput floatCurrent bandwidth of small input/output operations, addressed at the Snapshot.
Dell EMC XtremIO Snapshot Disk Small Throughput float
Current bandwidth of small input/output operations, addressed at the Snapshot.
Dell EMC XtremIO Snapshot Disk Small Write IOPS float Current IOPS of small write input/
output operations per second.
Dell EMC XtremIO Snapshot Disk Small Write
Throughput float Snapshot's small write bandwidth.
Dell EMC XtremIO Snapshot Disk Throughput float Total real-time read and write
bandwidth in MB per second.
Dell EMC XtremIO Snapshot Disk Unaligned IO
Ratio floatAccumulated number of unaligned I/O divided by the total accumulated number of I/Os to the Snapshot.
Dell EMC XtremIO Snapshot Disk Unaligned IO
Ratio Level string Event triggered whenever the unaligned-io-ratio level changes.
Dell EMC XtremIO Snapshot Disk Unaligned IOPS float Unaligned input/output operations per
second.
Dell EMC XtremIO Snapshot Disk Unaligned Read
IOPS float Current IOPS of unaligned read input/output operations per second.
Dell EMC XtremIO Snapshot Disk Unaligned Read
Throughput float Current bandwidth of unaligned read input/output operations.
Dell EMC XtremIO Snapshot Disk Unaligned
Throughput float Current IOPS of unaligned bandwidth input/output operations.
Dell EMC XtremIO Snapshot Disk Unaligned Write
IOPS float Current IOPS of unaligned write input/output operations per second.
Dell EMC XtremIO Snapshot Disk Unaligned Write
Throughput float Current bandwidth of unaligned write input/output operations
Dell EMC XtremIO Snapshot Disk Write IOPS float Total write real-time input/output
operations per second.
Dell EMC XtremIO Snapshot Disk Write Latency float Total real-time average latency of write
operations.
Dell EMC XtremIO Snapshot Disk Write Throughput float Total real-time write bandwidth in MB
per second
62 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Snapshot Status Object Severity string
Snapshot's severity, based on severity level of current Alerts (Alerts still uncleared) for this Snapshot. Possible values are 'clear', 'information', 'minor', 'major', and 'critical'.
Dell EMC XtremIO Snapshot Relationships Volume Parents string List of parent Volume resources
Dell EMC XtremIO SSD Details Firmware Version string Current firmware version of the SSD
Dell EMC XtremIO SSD Details Hardware
Revision string Hardware level of power supply unit
Dell EMC XtremIO SSD Details Identify LED string
Indicates whether the identification LED is illuminated for the SSD. The property value is reflected in the GUI LED icon
Dell EMC XtremIO SSD Details Index integer Index
Dell EMC XtremIO SSD Details Last IO Error Type string The last IO Error Type
Dell EMC XtremIO SSD Details Model Name string Vendor's assigned SSD model name
Dell EMC XtremIO SSD Details Part Number string A string assigned by EMC identifying
the part
Dell EMC XtremIO SSD Details SSD DPG State string Displays the state of the SSD related
to the DPG to which it belongs.
Dell EMC XtremIO SSD Details SSD Failure
Reason string SSD Failure Reason
Dell EMC XtremIO SSD Details SSD UID string UID (unique identification) of the SSD
that is inserted into the Slot.
Dell EMC XtremIO SSD Details Serial Number string Serial Number
Dell EMC XtremIO SSD Details Slot Number integer
Slot index in which SSD currently resides, or Slot index into which the currently-disconnected SSD was previously inserted
Dell EMC XtremIO SSD Details Swap LED string
Defines whether a replacement procedure is to be activated when a new SSD is inserted into the DAE.
Dell EMC XtremIO SSD Disk Bad Sector Count integer Number of bad sectors, detected in
the SSD
Dell EMC XtremIO SSD Disk Endurance
Remaining integer Percentage of SSD endurance remaining
Dell EMC XtremIO SSD Disk IOPS float SSD IOPS
Dell EMC XtremIO SSD Disk
Maximum Observed Throughput
float Maximum observed value of metric Maximum Observed Throughput.
63 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO SSD Disk
Maximum Observed Total IOPS
float Maximum observed value of metric Maximum Observed Total IOPS.
Dell EMC XtremIO SSD Disk
Percent Endurance Remaining Level
string Percent Endurance Remaining Level
Dell EMC XtremIO SSD Disk Read / Write Ratio float The ratio of read to write IOPS.
Dell EMC XtremIO SSD Disk Read IOPS float Read IOPS
Dell EMC XtremIO SSD Disk Read Throughput float Read Throughput
Dell EMC XtremIO SSD Disk SSD Size float The overall size of the SSD
Dell EMC XtremIO SSD Disk SSD Space In
Use float SSD Space In Use
Dell EMC XtremIO SSD Disk Throughput float Throughput of the SSD
Dell EMC XtremIO SSD Disk Useful SSD
Space float The useful size of this specific SSD
Dell EMC XtremIO SSD Disk Write IOPS float Write IOPS for SSD
Dell EMC XtremIO SSD Disk Write Throughput float Write Throughput of the SSD
Dell EMC XtremIO SSD Status Certainty string
XMS Certainty. Indicates confidence that XMS and the cluster are synchronized
Dell EMC XtremIO SSD Status Diagnostic Health
State string Reflects the health of the SSD device itself
Dell EMC XtremIO SSD Status Enabled State string
Indicates whether the SSD is currently enabled or disabled, either by the user or the cluster
Dell EMC XtremIO SSD Status Encryption Status string SSD's encryption (Data at Rest) status
Dell EMC XtremIO SSD Status FRU Lifecycle
State string SSD's FRU state, using the generic FRU transition states
Dell EMC XtremIO SSD Status Firmware Version
Error string Reason for FRU diagnostic failure when a firmware problem exists
Dell EMC XtremIO SSD Status Health State string The SSD's state of health
Dell EMC XtremIO SSD Status IO Error ASC string The ASC code of the most recent I/O
error
Dell EMC XtremIO SSD Status IO Error ASCQ string The ASCQ code of the most recent I/O
error
Dell EMC XtremIO SSD Status IO Error Sense
Code integer The sense code of an I/O error
64 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO SSD Status IO Error Vendor
Specific string Vendor specific information string of the most recent I/O error
Dell EMC XtremIO SSD Status Last IO Error
Timestamp integer Timestamp of the last recorded I/O error
Dell EMC XtremIO SSD Status Object Severity string
SSD's severity, based on severity level of current Alerts (Alerts still uncleared) for this SSD
Dell EMC XtremIO SSD Status SSD Link 1 Health
State stringReflects the SSD health state. Relates to the first port, which should be connected to Storage Controller-1.
Dell EMC XtremIO SSD Status SSD Link 2 Health
State stringReflects the SSD health state. Relates to the first port, which should be connected to Storage Controller-2.
Dell EMC XtremIO SSD Status Smart Error ASC string The ASC code of the most recent
SMART error (two hex digits)
Dell EMC XtremIO SSD Status Smart Error ASCQ string The ASCQ code of the most recent
SMART error (two hex digits)
Dell EMC XtremIO SSD Status Status LED string LED state, indicating SSD object faults
Dell EMC XtremIO SSD Relationships Data Protection
Group Parents string List of parent Data Protection Group resources
Dell EMC XtremIO SSD Relationships Disk Array
Enclosure Parents string List of parent Disk Array Enclosure resources
Dell EMC XtremIO Storage Controller Details Active IPMI Port string The port which is currently being used
for IPMI.
Dell EMC XtremIO Storage Controller Details BIOS Firmware
Version string The BIOS firmware version of the storage controller.
Dell EMC XtremIO Storage Controller Details DAE Discovery
Needed string Whether or not DAE discovery is needed.
Dell EMC XtremIO Storage Controller Details DAE PSU
Discovery Needed string Whether or not the cluster has detected a new DAE PSU.
Dell EMC XtremIO Storage Controller Details Dedicated IPMI
Port Speed string Negotiated speed of the dedicated IPMI port.
Dell EMC XtremIO Storage Controller Details FC HBA Hardware
Revision string Detected Fibre Channel host bus adaptors hardware revision.
Dell EMC XtremIO Storage Controller Details FC HBA Model string Fibre Channel host bus adaptors
hardware model.
Dell EMC XtremIO Storage Controller Details IB 1 Link Downed integer The total number of times this port
was declared 'down'.
Dell EMC XtremIO Storage Controller Details IB 1 Link Downed
Per Long Period integerThe number of times InfiniBand port 1 was declared 'down' over the past five minutes.
Dell EMC XtremIO Storage Controller Details IB 1 Link Downed
Per Minute integerThe number of times InfiniBand port 1 was declared 'down' in the past minute.
65 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Storage Controller Details IB 1 Link Error
Recoveries integerThe number of times this InfiniBand port successfully completed a link error recovery procedure.
Dell EMC XtremIO Storage Controller Details
IB 1 Link Error Recoveries Per Long Period
integerThe number of link error recoveries by InfiniBand port 1 over the past five minutes.
Dell EMC XtremIO Storage Controller Details
IB 1 Link Error Recoveries Per Minute
integer The number of link error recoveries for InfiniBand port 1 over the past minute.
Dell EMC XtremIO Storage Controller Details IB 1 Local Link
Integrity Errors integerThe total number of local link integrity errors encountered by InfiniBand port 1.
Dell EMC XtremIO Storage Controller Details
IB 1 Local Link Integrity Errors Per Long Period
integerThe number of local link integrity errors encountered by InfiniBand port 1 over the past five minutes.
Dell EMC XtremIO Storage Controller Details
IB 1 Local Link Integrity Errors Per Minute
integerThe number of local link integrity errors encountered by InfiniBand port 1 over the past minute.
Dell EMC XtremIO Storage Controller Details IB 1 Peer OID string
The object index number of the specific peer object connected to the storage controller.
Dell EMC XtremIO Storage Controller Details IB 1 Port In Peer
Index integer
Index of the port within the storage controller this port is connected to (0 if the port is unconnected). The value is meaningful only when port_peer_type is not none.
Dell EMC XtremIO Storage Controller Details IB 1 Port Peer
Type stringDefines whether port 1 is connected to a storage controller, another switch, or is disconnected.
Dell EMC XtremIO Storage Controller Details IB 1 Port
Received Errors integer The total number of received errors encountered by InfiniBand port 1.
Dell EMC XtremIO Storage Controller Details
IB 1 Port Received Errors Per Long Period
integerThe number of received errors encountered by InfiniBand port 1 over the past five minutes.
Dell EMC XtremIO Storage Controller Details
IB 1 Port Received Errors Per Minute
integerThe number of received errors encountered by InfiniBand port 1 over the past minute.
Dell EMC XtremIO Storage Controller Details
IB 1 Port Received Remote Physical Errors
integerThe total number of received remote physical errors encountered by InfiniBand port 1.
Dell EMC XtremIO Storage Controller Details
IB 1 Port Received Remote Physical Errors Per Long Period
integerThe number of received remote physical errors over the past five minutes by InfiniBand port 1.
Dell EMC XtremIO Storage Controller Details
IB 1 Port Received Remote Physical Errors Per Minute
integerNumber of packets received on this InfiniBand port with errors over the past minute.
66 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Storage Controller Details IB 1 Symbol
Errors integer The total number of symbol errors encountered by InfiniBand port 1.
Dell EMC XtremIO Storage Controller Details
IB 1 Symbol Errors Per Long Period
integerThe number of symbol errors encountered by InfiniBand port 1 over the past minute.
Dell EMC XtremIO Storage Controller Details IB 1 Symbol
Errors Per Minute integerThe number of symbol errors encountered by InfiniBand port 1 in the past minute.
Dell EMC XtremIO Storage Controller Details IB 2 Link Downed integer The total number of times InfiniBand
port 2 was declared 'down'.
Dell EMC XtremIO Storage Controller Details IB 2 Link Downed
Per Long Period integerThe number of times InfiniBand port 2 was declared 'down' over the past five minutes.
Dell EMC XtremIO Storage Controller Details IB 2 Link Downed
Per Minute integerThe number of times this InfiniBand port was marked as 'down' over the past minute.
Dell EMC XtremIO Storage Controller Details IB 2 Link Error
Recoveries integerNumber of times this InfiniBand port successfully completed a link error recovery procedure.
Dell EMC XtremIO Storage Controller Details
IB 2 Link Error Recoveries Per Long Period
integerThe number of link error recoveries by InfiniBand port 2 over the past five minutes.
Dell EMC XtremIO Storage Controller Details
IB 2 Link Error Recoveries Per Minute
integer The number of link error recoveries by InfiniBand port 2 over the past minute.
Dell EMC XtremIO Storage Controller Details IB 2 Local Link
Integrity Errors integerThe total number of local link integrity errors encountered by InfiniBand port 2.
Dell EMC XtremIO Storage Controller Details
IB 2 Local Link Integrity Errors Per Long Period
integerThe number of local link integrity errors this InfiniBand port has encountered over the past five minutes.
Dell EMC XtremIO Storage Controller Details
IB 2 Local Link Integrity Errors Per Minute
integerNumber of local link integrity errors encountered by InfiniBand port 2 over the past minute.
Dell EMC XtremIO Storage Controller Details IB 2 Peer OID string
The object index number of the specific peer object connected to the storage controller.
Dell EMC XtremIO Storage Controller Details IB 2 Port In Peer
Index integer
Index of the port within the storage controller this port is connected to (0 if the port is unconnected). The value is meaningful only when port_peer_type is not none.
Dell EMC XtremIO Storage Controller Details IB 2 Port Peer
Type stringDefines whether port 2 is connected to a storage controller, another switch, or is disconnected.
Dell EMC XtremIO Storage Controller Details IB 2 Port
Received Errors integer Number of packets received with errors by InfiniBand port 2.
67 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Storage Controller Details
IB 2 Port Received Errors Per Long Period
integerThe number of packets received with error by InfiniBand port 2 over the past five minutes.
Dell EMC XtremIO Storage Controller Details
IB 2 Port Received Errors Per Minute
integerNumber of packets received on this InfiniBand port with errors over the past minute.
Dell EMC XtremIO Storage Controller Details
IB 2 Port Received Remote Physical Errors
integerTotal number of received remote physical errors encountered by InfiniBand port 2.
Dell EMC XtremIO Storage Controller Details
IB 2 Port Received Remote Physical Errors Per Long Period
integerThe number of remote physical errors this InfiniBand port has encountered over the past five minutes.
Dell EMC XtremIO Storage Controller Details
IB 2 Port Received Remote Physical Errors Per Minute
integer The number of remote physical errors encountered by the InfiniBand port.
Dell EMC XtremIO Storage Controller Details IB 2 Symbol
Errors integer Total number of symbol errors on this InfiniBand port.
Dell EMC XtremIO Storage Controller Details
IB 2 Symbol Errors Per Long Period
integerThe number of symbol errors this InfiniBand port has encountered over the past five minutes.
Dell EMC XtremIO Storage Controller Details IB 2 Symbol
Errors Per Minute integer The number of symbol errors on this InfiniBand port in the past minute.
Dell EMC XtremIO Storage Controller Details IB Address 1 string Storage controller's internal backend
InfiniBand addresses for port 1.
Dell EMC XtremIO Storage Controller Details IB Address 2 string Storage controller's internal backend
InfiniBand addresses for port 2.
Dell EMC XtremIO Storage Controller Details IB Switch PSU
Discovery Needed string Whether or not the cluster has detected a new InfiniBand PSU.
Dell EMC XtremIO Storage Controller Details IPMI Address string IPMI address and subnet for the
storage controller.
Dell EMC XtremIO Storage Controller Details IPMI Address
Subnet string Subnet of the IPMI's address.
Dell EMC XtremIO Storage Controller Details IPMI BMC
Firmware Version string The firmware version of the IPMI.
Dell EMC XtremIO Storage Controller Details
IPMI BMC Hardware Revision
string The hardware revision of the IPMI.
Dell EMC XtremIO Storage Controller Details IPMI BMC Model string The hardware model of the IPMI.
Dell EMC XtremIO Storage Controller Details IPMI Connection
Error Reason string The reason for the disconnection from the Storage Controller's IPMI.
Dell EMC XtremIO Storage Controller Details IPMI Gateway IP string The IPMI default gateway's IP address.
68 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Storage Controller Details Identify LED string
Whether or not the identification LED is illuminated for the Storage Controller.
Dell EMC XtremIO Storage Controller Details Index integer The index of the storage controller.
Dell EMC XtremIO Storage Controller Details Index In Brick integer Index in brick.
Dell EMC XtremIO Storage Controller Details Is SYM Node string
Indicates if this storage controller is the storage controller running the SYM.
Dell EMC XtremIO Storage Controller Details
Local Disk Controller Firmware Version
string Storage controller's current firmware version.
Dell EMC XtremIO Storage Controller Details
Local Disk Controller Hardware Revision
string Revision for the local disk storage storage controller hardware.
Dell EMC XtremIO Storage Controller Details Local Disk Count integer Number of local disks for the storage
controller.
Dell EMC XtremIO Storage Controller Details Low Ram Level string The value from the Storage
Controller's 'RAM Level Low' indicator.
Dell EMC XtremIO Storage Controller Details Management
Gateway IP string The IPMI default gateway's IP management.
Dell EMC XtremIO Storage Controller Details Management Port
Speed string Management port speed.
Dell EMC XtremIO Storage Controller Details Monitored UPS
Count integer Number of BBUs that are connected to the storage controller.
Dell EMC XtremIO Storage Controller Details Node CSID integer Internal storage controller naming
index number.
Dell EMC XtremIO Storage Controller Details
Node Front Panel Temperature State
string The temperature sensor reading for above normal temperatures.
Dell EMC XtremIO Storage Controller Details Node GUID string
GUID (Globally Unique Identifier) hardwired in the physical storage controller.
Dell EMC XtremIO Storage Controller Details Node Index integer Node index.
Dell EMC XtremIO Storage Controller Details Node Manager
Address string The IP addresses used to access the storage controller manager.
Dell EMC XtremIO Storage Controller Details Node Manager
Address Subnet string The storage controller's subnet mask management IP.
Dell EMC XtremIO Storage Controller Details
Node Manager Connection Error Reason
stringReason for the last disconnection between the XMS and the Storage Controller.
69 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Storage Controller Details Node PSU Count integer
Storage controller's number of storage controller PSU objects and the list of their object IDs. There should be two PSUs per storage controller.
Dell EMC XtremIO Storage Controller Details Node PSU
Discovery Needed stringWhether or not the cluster has detected a new Storage Controller PSU.
Dell EMC XtremIO Storage Controller Details Node Stop
Reason string The reason reported for the Storage Controller stoppage.
Dell EMC XtremIO Storage Controller Details Node Stop Type string The type of the most recent stop.
Dell EMC XtremIO Storage Controller Details OS Upgrade
Current Step Info string Information about the current step of the OS upgrade (if any).
Dell EMC XtremIO Storage Controller Details OS Version string
Storage Controller operating system version, equivalent to the firmware for other components.
Dell EMC XtremIO Storage Controller Details PCI 10GE HBA
Firmware Version string iSCSI host bus adaptors firmware version.
Dell EMC XtremIO Storage Controller Details
PCI 10GE HBA Hardware Revision
string iSCSI host bus adaptors hardware revision.
Dell EMC XtremIO Storage Controller Details PCI 10GE HBA
Model string iSCSI host bus adaptors model name.
Dell EMC XtremIO Storage Controller Details
PCI Disk Controller Firmware Version
string DAE controller's firmware version.
Dell EMC XtremIO Storage Controller Details
PCI Disk Controller Hardware Revision
string DAE controller's hardware revision.
Dell EMC XtremIO Storage Controller Details PCI IB HBA
Firmware Version string InfiniBand host bus adaptors firmware revision.
Dell EMC XtremIO Storage Controller Details
PCI IB HBA Hardware Revision
string InfiniBand host bus adaptors hardware revision.
Dell EMC XtremIO Storage Controller Details PCI IB HBA
Model string Infiniband host bus adaptors hardware model.
Dell EMC XtremIO Storage Controller Details SAS 1 Port Rate string Rate of the first serial attached SCSI
(SAS) port used.
Dell EMC XtremIO Storage Controller Details SAS 2 Port Rate string Rate of the second serial attached
SCSI (SAS) port used.
Dell EMC XtremIO Storage Controller Details SC Start
Timestamp integer The last time this storage controller was started.
Dell EMC XtremIO Storage Controller Details
SC Start Timestamp Display
string The storage controller's last start time.
70 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Storage Controller Details SSD Count integer The total number of SSDs in this
storage controller's X-Brick.
Dell EMC XtremIO Storage Controller Details SSD Discovery
Needed string Whether or not the cluster has detected a new SSD.
Dell EMC XtremIO Storage Controller Details Serial Number string The serial number of the storage
controller.
Dell EMC XtremIO Storage Controller Details Software Version string Software version.
Dell EMC XtremIO Storage Controller Details Status LED string Status LED.
Dell EMC XtremIO Storage Controller Details Targets Discovery
Needed string Whether or not the cluster has detected new targets.
Dell EMC XtremIO Storage Controller Details UPS Discovery
Needed string Whether or not BBU discovery is needed.
Dell EMC XtremIO Storage Controller Details Upgrade Failure
Reason string The reason for the failed upgrade (if any).
Dell EMC XtremIO Storage Controller Network IB 1 Link Rate In
Gbps string The link rate of InfiniBand port 1.
Dell EMC XtremIO Storage Controller Network IB 2 Link Rate In
Gbps string The InfiniBand link rate for port 2.
Dell EMC XtremIO Storage Controller Status Backend Storage
Controller State string The state of the backend Storage Controller.
Dell EMC XtremIO Storage Controller Status Current Health
State string The current health state of the Storage Controller.
Dell EMC XtremIO Storage Controller Status DAE Controller
Discovery Needed string Whether or not the cluster has detected new DAE controllers.
Dell EMC XtremIO Storage Controller Status DIMM Correctable
Errors integer The number of DIMM ECC correctable errors.
Dell EMC XtremIO Storage Controller Status DIMM Health
State string The health state of the DIMM.
Dell EMC XtremIO Storage Controller Status
Dedicated IPMI Link Connection State
stringThe state of the link between the dedicated IPMI port and the other Storage Controller.
Dell EMC XtremIO Storage Controller Status Dedicated IPMI
Port State string The state of the dedicated Ethernet port used for IPMI access.
Dell EMC XtremIO Storage Controller Status Enabled State string
Indicates whether the Storage Controller is currently enabled or disabled, either by user or the cluster.
Dell EMC XtremIO Storage Controller Status FRU Lifecycle
State stringThe Storage Controller's FRU state, using the generic FRU transition states.
Dell EMC XtremIO Storage Controller Status Fan Health State string
The health state of the least healthy fan, based on both analog and discrete sensors.
71 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Storage Controller Status Firmware Version
Error stringWhether or not the firmware or OS upgrade has failed or is in the process of upgrading.
Dell EMC XtremIO Storage Controller Status IB 1 Link Health
Level string The most severe problem detected on InfiniBand port 1.
Dell EMC XtremIO Storage Controller Status IB 1 Port
Misconnection string Whether or not a problem exists in InfiniBand port 1.
Dell EMC XtremIO Storage Controller Status IB 1 Port State string The state of the Storage Controller's
InfiniBand port 1.
Dell EMC XtremIO Storage Controller Status IB 2 Link Health
Level string The most severe problem detected over this InfiniBand link.
Dell EMC XtremIO Storage Controller Status IB 2 Port
Misconnection stringWhether or not there is a connection problem between the Storage Controller and InfiniBand port 2.
Dell EMC XtremIO Storage Controller Status IB 2 Port State string State of the InfiniBand port 2.
Dell EMC XtremIO Storage Controller Status IB Switches
Discovery Needed string Whether or not the cluster has detected new InfiniBand switches.
Dell EMC XtremIO Storage Controller Status ISCSI Daemon
State string The state of the ISCSI daemon.
Dell EMC XtremIO Storage Controller Status Internal Sensor
Health State string
Reflects health state of the least healthy of all temperature/voltage/fan/current/internal sensor types. Value is based on both the analog and discrete sensors of each type.
Dell EMC XtremIO Storage Controller Status Journal State string The state of the Storage Controller's
journal.
Dell EMC XtremIO Storage Controller Status Local Disk
Discovery Needed string Whether or not the cluster has detected a new local disk.
Dell EMC XtremIO Storage Controller Status Management Link
Health Level string The Storage Controller's management port health state.
Dell EMC XtremIO Storage Controller Status Management Port
State string The Storage Controller's management port state.
Dell EMC XtremIO Storage Controller Status Node Health
State string Health state of the Storage Controller and its components.
Dell EMC XtremIO Storage Controller Status Node Journaling
Health State string The health state of the journaling component.
Dell EMC XtremIO Storage Controller Status Node Manager
Connection State string The state of the connection between XMS and Storage Controller manager.
Dell EMC XtremIO Storage Controller Status OS Upgrade
Current Step integer The current step of the OS upgrade.
Dell EMC XtremIO Storage Controller Status Object Severity string Object severity of the storage
controller.
Dell EMC XtremIO Storage Controller Status Remote Journal
Health State string The health state of the remote journal.
72 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Storage Controller Status SAS 1 HBA Port
Health Level string The health level of the Storage Controller's SAS port 1.
Dell EMC XtremIO Storage Controller Status SAS 1 Port State string The state of the first SAS port used.
Dell EMC XtremIO Storage Controller Status SAS 2 HBA Port
Health Level string The health level of the Storage Controller's SAS port 2.
Dell EMC XtremIO Storage Controller Status SAS 2 Port State string The state of the SAS port 2.
Dell EMC XtremIO Storage Controller Status SC DAE Access
State string DAE access state of the Storage Controller.
Dell EMC XtremIO Storage Controller Status Temperature
Health State stringThe health state of the least healthy temperature sensor, based on both analog and discrete sensors.
Dell EMC XtremIO Storage Controller Status Upgrade State string The state of the last upgrade process
for the Storage Controller.
Dell EMC XtremIO Storage Controller Status Voltage Health
State string The aggregated health state of the voltage sensors.
Dell EMC XtremIO Storage Controller
User Configuration
Management Port Auto-Negotation string Indicates if auto-negotiation is enabled
(default) or disabled.
Dell EMC XtremIO Storage Controller
User Configuration
Management Port Duplex string
Ethernet port duplex. The current port configuration applies if the port is full duplex or half duplex.
Dell EMC XtremIO Storage Controller Relationships Host Interface
Children string List of child Host Interface resources
Dell EMC XtremIO Storage Controller Relationships InfiniBand Switch
Children string List of child InfiniBand Switch resources
Dell EMC XtremIO Storage Controller Relationships Local Disk
Children string List of child Local Disk resources
Dell EMC XtremIO Storage Controller Relationships PSU Children string List of child PSU resources
Dell EMC XtremIO Storage Controller Relationships X-Brick Parents string List of parent X-Brick resources
Dell EMC XtremIO Volume Details Alignment Offset integer The alignment offset range(between
0-15).
Dell EMC XtremIO Volume Details Created From
Volume string
This parameter contains the snapped_object Volume name, as it was at the Snapshot's creation time, or null when the Volume was not created from a Snapshot. The string remains unchanged when the ancestor is renamed, deleted or reassigned.
Dell EMC XtremIO Volume Details Destination
Snapshot Count integer Number of Volumes directly Snapshotted from this Volume
Dell EMC XtremIO Volume Details Index integer
Volume's index number as defined by the XMS upon its creation (a unique positive number)
73 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Volume Details LB Size integer The "sector size" (LB size) of the
Volume
Dell EMC XtremIO Volume Details LUN Mapping
Count integer Number of LUN mappings defined for this Volume
Dell EMC XtremIO Volume Details NAA Name string
Volume's WWN/NAA name, globally unique and unique over time, set by the XMS (or by cluster) once a LUN is mapped to the Volume for the first time
Dell EMC XtremIO Volume Details Snapshot Group
ID string The Volume Snapshot Group (VSG) Index
Dell EMC XtremIO Volume Details Snapshot Type string The Snapshot is regular (default) or
readonly.
Dell EMC XtremIO Volume Details Unaligned IO
Alerts stringWhen this Volume parameter is set to disabled (default), no Alerts are sent for a high number of unaligned I/Os.
Dell EMC XtremIO Volume Details
VAAI Thin Provisioning Alerts
string
The VAAI Soft Limit warning for this Volume is reported when monitoring is enabled. The threshold is a cluster-wide value as configured in the cluster vaai_tp_limit. The default is disabled.
Dell EMC XtremIO Volume Details Volume Access string Denotes the type of volume and its
accessibility.
Dell EMC XtremIO Volume Details Volume Size float Total provisioned capacity. Volume KB
size as exposed to Initiators
Dell EMC XtremIO Volume Details Volume Type string Denotes the Volume type. Values:
[regular or readonly]
Dell EMC XtremIO Volume Disk
Accumulated Read Operation Count
integerTotal accumulative number of read operations having occurred during the Volume's lifespan
Dell EMC XtremIO Volume Disk Accumulated Size
of Read floatAccumulative capacity KB size of read operations having occurred during the Volume's lifespan
Dell EMC XtremIO Volume Disk Accumulated Size
of Write floatAccumulative capacity KB size of write operations having occurred during the Volume's lifespan
Dell EMC XtremIO Volume Disk
Accumulated Small Read Operation Count
integer Accumulated number of small reads input/output operations of the Volume
Dell EMC XtremIO Volume Disk
Accumulated Small Write Operation Count
integerAccumulated number of small writes input/output operations recursively contained by this Volume
Dell EMC XtremIO Volume Disk
Accumulated Unaligned Read Operation Count
integer Volume's accumulated number of I/Os since adding an Initiator.
Dell EMC XtremIO Volume Disk
Accumulated Unaligned Write Operation Count
integer Cluster's total number of accumulated unaligned writes
74 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Volume Disk
Accumulated Write Operation Count
integerAccumulative number of write operations having occurred during the Volume's lifespan
Dell EMC XtremIO Volume Disk Average Latency float Average Latency
Dell EMC XtremIO Volume Disk IOPS float IOPS
Dell EMC XtremIO Volume Disk Logical Space In
Use float Logical Space In Use
Dell EMC XtremIO Volume Disk Logical Space In
Use float Logical space in use.
Dell EMC XtremIO Volume Disk
Maximum Observed Throughput
float Maximum observed value of metric Maximum Observed Throughput.
Dell EMC XtremIO Volume Disk
Maximum Observed Total IOPS
float Maximum observed value of metric Maximum Observed Total IOPS.
Dell EMC XtremIO Volume Disk Read / Write Ratio float The ratio of read to write IOPS.
Dell EMC XtremIO Volume Disk Read IOPS float Read IOPS
Dell EMC XtremIO Volume Disk Read Latency float Read Latency
Dell EMC XtremIO Volume Disk Read Throughput float Read Throughput
Dell EMC XtremIO Volume Disk Small IO Ratio float Small IO Ratio
Dell EMC XtremIO Volume Disk Small IOPS float Small IOPS
Dell EMC XtremIO Volume Disk Small Read IOPS float Small Read IOPS
Dell EMC XtremIO Volume Disk Small Read
Throughput float Small Read Throughput
Dell EMC XtremIO Volume Disk Small Throughput float Small Throughput
Dell EMC XtremIO Volume Disk Small Write IOPS float Small Write IOPS
Dell EMC XtremIO Volume Disk Small Write
Throughput float Small Write Throughput
Dell EMC XtremIO Volume Disk Throughput float Throughput
Dell EMC XtremIO Volume Disk Unaligned IO
Ratio float Unaligned IO Ratio
Dell EMC XtremIO Volume Disk Unaligned IOPS float Unaligned IOPS
75 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO Volume Disk Unaligned Read
IOPS float Unaligned Read IOPS
Dell EMC XtremIO Volume Disk Unaligned Read
Throughput float Unaligned Read Throughput
Dell EMC XtremIO Volume Disk Unaligned
Throughput float Unaligned Throughput
Dell EMC XtremIO Volume Disk Unaligned Write
IOPS float Unaligned Write IOPS
Dell EMC XtremIO Volume Disk Unaligned Write
Throughput float Unaligned Write Throughput
Dell EMC XtremIO Volume Disk Write IOPS float Write IOPS
Dell EMC XtremIO Volume Disk Write Latency float Write Latency
Dell EMC XtremIO Volume Disk Write Throughput float Write Throughput
Dell EMC XtremIO Volume Status Certainty string
Indicates confidence that the XMS and the cluster are synchronized. The value changes from OK if a request is sent while the XMS is unable to determine the success of the request.
Dell EMC XtremIO Volume Status Object Severity string
Volume's severity, based on severity level of current Alerts (Alerts still uncleared) for this Volume
Dell EMC XtremIO Volume Status Small IO Ratio
Level string Event triggered whenever the unaligned-io-ratio level changes
Dell EMC XtremIO Volume Status Unaligned IO
Ratio Level string Event triggered whenever the unaligned-io-ratio level changes
Dell EMC XtremIO Volume Relationships Cluster Parents string List of parent Cluster resources
Dell EMC XtremIO Volume Relationships Datastore Parents string List of parent Datastore resources
Dell EMC XtremIO Volume Relationships
Dell EMC XtremIO Related Objects Parents
string List of parent Dell EMC XtremIO Related Objects resources
Dell EMC XtremIO Volume Relationships
Dell EMC XtremIO Related Objects Parents
string List of parent Dell EMC XtremIO Related Objects resources
Dell EMC XtremIO Volume Relationships Dell EMC XtremIO
Tag Parents string List of parent Dell EMC XtremIO Tag resources
Dell EMC XtremIO Volume Relationships Snapshot
Children string List of child Snapshot resources
Dell EMC XtremIO X-Brick Details Index integer
The X-Brick index number as defined by the XtremIO Management Server upon its creation (a unique positive number).
76 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
RESOURCE KIND RESOURCE GROUP
RESOURCE ATTRIBUTE
ATTRIBUTE TYPE ATTRIBUTE DESCRIPTION
Dell EMC XtremIO X-Brick Details Index In System integer The X-Brick's index.
Dell EMC XtremIO X-Brick Details SSD Count integer The X-Brick's total number of SSDs.
Dell EMC XtremIO X-Brick Details Storage Controller
Count integer X-Brick's total number of Storage Controllers.
Dell EMC XtremIO X-Brick Status Brick State string X-Brick's current state
Dell EMC XtremIO X-Brick Status Object Severity string
X-Brick severity, based on severity level of current Alerts (Alerts still uncleared) for this X-Brick. Possible values are 'clear', 'information', 'minor', 'major', and 'critical'.
Dell EMC XtremIO X-Brick Relationships Battery Backup
Unit Children string List of child Battery Backup Unit resources
Dell EMC XtremIO X-Brick Relationships Cluster Parents string List of parent Cluster resources
Dell EMC XtremIO X-Brick Relationships Data Protection
Group Children string List of child Data Protection Group resources
Dell EMC XtremIO X-Brick Relationships
Disk Array Enclosure Children
string List of child Disk Array Enclosure resources
Dell EMC XtremIO X-Brick Relationships Storage Controller
Children string List of child Storage Controller resources
77 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
11. Appendix II: Alerts
The Management Pack for Dell EMC XtremIO populates alerts originating from the XtremIO REST API and makes them available in vROps. Refer to the full list of alerts as shown below:
• Battery Backup Unit High Threshold UPS Load
• Battery Backup Unit Low Threshold UPS Load
• Battery Backup Unit Medium Threshold UPS Load
• Battery Backup Unit No UPS Load
• Battery Backup Unit UPS Bypass Active Failure
• Battery Backup Unit UPS Bypass Active Failure With An Unexpected Value
• Battery Backup Unit UPS Failure With An Unexpected Value
• Battery Backup Unit UPS FRU Disconnected
• Battery Backup Unit UPS FRU Failed
• Battery Backup Unit UPS FRU Prepare Failed
• Battery Backup Unit UPS FRU Uninitialized
• Battery Backup Unit UPS Firmware Invalid
• Battery Backup Unit UPS Firmware Mismatch
• Battery Backup Unit UPS Firmware Upgrading
• Battery Backup Unit UPS Low Battery Failure
• Battery Backup Unit UPS Low Battery Failure With An Unexpected Value
• Battery Backup Unit UPS Low Battery With No Input
• Battery Backup Unit UPS Low Battery With No Input And An Unexpected Value
• Battery Backup Unit UPS Low Battery Run Failure
• Battery Backup Unit UPS Low Battery Run Failure With An Unexpected Value
• Battery Backup Unit UPS Needs Battery Replaced
• Battery Backup Unit UPS No External Power
• Battery Backup Unit UPS Node 1 Disconnected
• Battery Backup Unit UPS Node 2 Disconnected
• Battery Backup Unit UPS Node Disconnected
• Battery Backup Unit UPS Overload Failure True
• Battery Backup Unit UPS Overload Failure With An Unexpected Value
• Battery Backup Unit UPS System Disabled
• Battery Backup Unit UPS User Disabled
• Battery Backup Unit BBU Event
• Cluster Consistency Group Add Pending
• Cluster Consistency Group Modify Pending
• Cluster Consistency Group Remove Pending
• Cluster Discovery Chap Initiators Missing Credentials
• Cluster Initiator Group Add Pending
78 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
• Cluster Initiator Group Modify Pending
• Cluster Initiator Group Remove Pending
• Cluster Initiator Add Pending
• Cluster Initiator Modify Pending
• Cluster Initiator Remove Pending
• Cluster Snapshot Group Add Pending
• Cluster Snapshot Group Modify Pending
• Cluster Snapshot Group Remove Pending
• Cluster Event
• Data Protection Group RaidGroup Prepare 20 To 40 Percent Done
• Data Protection Group RaidGroup Prepare 0 To 20 Percent Done
• Data Protection Group RaidGroup Prepare 40 To 60 Percent Done
• Data Protection Group RaidGroup Prepare 60 To 80 Percent Done
• Data Protection Group RaidGroup Prepare 99 Percent Done
• Data Protection Group RaidGroup Rebuild 0 To 20 Percent Done
• Data Protection Group RaidGroup Rebuild 20 To 40 Percent Done
• Data Protection Group RaidGroup Rebuild 40 To 60 Percent Done
• Data Protection Group RaidGroup Rebuild 60 To 80 Percent Done
• Data Protection Group RaidGroup Rebuild 99 Percent Done
• Data Protection Group RaidGroup Degraded
• Data Protection Group RaidGroup Double Degrade
• Data Protection Group RaidGroup Dual Failure
• Data Protection Group RaidGroup Error
• Data Protection Group RaidGroup Limited Physical Capacity
• Data Protection Group RaidGroup Is Low On Available Rebuilds
• Data Protection Group RaidGroup Has No Available Rebuilds
• Data Protection Group RaidGroup Has No Free Physical Capacity
• Data Protection Group RaidGroup Has Very Limited Physical Capacity
• Data Protection Group Event
• Disk Array Enclosure DAE LCC Connected Different Bricks
• Disk Array Enclosure DAE LCC Connected One Storage Controller
• Disk Array Enclosure JBOD FRU Disconnected
• Disk Array Enclosure JBOD FRU Failed
• Disk Array Enclosure JBOD FRU Prepare Failed
• Disk Array Enclosure JBOD FRU Uninitialized
• Disk Array Enclosure JBOD Controller FRU Disconnected
• Disk Array Enclosure JBOD Controller FRU Failed
• Disk Array Enclosure JBOD Controller FRU Prepare Failed
79 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
• Disk Array Enclosure JBOD Controller FRU Uninitialized
• Disk Array Enclosure JBOD Controller Firmware Invalid
• Disk Array Enclosure JBOD Controller Firmware Mismatch
• Disk Array Enclosure JBOD Controller Firmware Upgrading
• Disk Array Enclosure JBOD Controller System Disabled
• Disk Array Enclosure JBOD Controller User Disabled
• Disk Array Enclosure LCC SAS2 Port Down
• Disk Array Enclosure Node LCC Level 2 Unknown
• Disk Array Enclosure Node LCC Level 3 Warning
• Disk Array Enclosure Node LCC Level 4 Minor
• Disk Array Enclosure Node LCC Level 5 Major
• Disk Array Enclosure Node LCC Level 6 Critical
• Disk Array Enclosure SAS Connectivity Degraded
• Disk Array Enclosure SAS Connectivity Down
• Disk Array Enclosure SAS SAS1 Port Down
• Disk Array Enclosure DAE Event
• InfiniBand Switch InfiniBand Switch Fan Drawer Failed
• InfiniBand Switch InfiniBand Switch FRU Disconnected
• InfiniBand Switch InfiniBand Switch FRU Failed
• InfiniBand Switch InfiniBand Switch FRU Prepare Failed
• InfiniBand Switch InfiniBand Switch FRU Uninitialized
• InfiniBand Switch InfiniBand Switch Firmware Invalid
• InfiniBand Switch InfiniBand Switch Firmware Mismatch
• InfiniBand Switch InfiniBand Switch Firmware Upgrading
• InfiniBand Switch InfiniBand Switch Level 2 Unknown
• InfiniBand Switch InfiniBand Switch Level 3 Warning
• InfiniBand Switch InfiniBand Switch Level 4 minor
• InfiniBand Switch InfiniBand Switch Level 5 major
• InfiniBand Switch InfiniBand Switch level 6 critical
• InfiniBand Switch InfiniBand Switch One Fan Failed
• InfiniBand Switch InfiniBand Switch S2S IB1 Port Down
• InfiniBand Switch InfiniBand Switch S2S IB2 Port Down
• InfiniBand Switch InfiniBand Switch System Disabled
• InfiniBand Switch InfiniBand Switch Unknown Model
• InfiniBand Switch InfiniBand Switch User Disabled
• InfiniBand Switch InfiniBand Switch Wrong Connection
• InfiniBand Switch InfiniBand Switch PSU FRU Disconnected
• InfiniBand Switch InfiniBand Switch PSU FRU Failed
80 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
• InfiniBand Switch InfiniBand Switch PSU FRU Prepare Failed
• InfiniBand Switch InfiniBand Switch PSU FRU Uninitialized
• InfiniBand Switch InfiniBand Switch PSU Firmware Invalid
• InfiniBand Switch InfiniBand Switch PSU Firmware Mismatch
• InfiniBand Switch InfiniBand Switch PSU Firmware Upgrading
• InfiniBand Switch InfiniBand Switch PSU No External Power
• InfiniBand Switch InfiniBand Switch PSU System Disabled
• InfiniBand Switch InfiniBand Switch PSU User Disabled
• InfiniBand Switch Event
• Local Disk Disk Empty
• Local Disk Unanticipated Disk
• Local Disk Disk Uninitialized
• Local Disk Unsupported Disk
• Local Disk Local Disk FRU Disconnected
• Local Disk Local Disk FRU Failed
• Local Disk Local Disk FRU Prepare Failed
• Local Disk Local Disk FRU Uninitialized
• Local Disk Local Disk Firmware Invalid
• Local Disk Local Disk Firmware Mismatch
• Local Disk Local Disk Firmware Upgrading
• Local Disk Local Disk System Disabled
• Local Disk Local Disk User Disabled
• Local Disk Event
• PSU DAE PSU AC Failed
• PSU DAE PSU AC Lost
• PSU DAE PSU AC Out of Range
• PSU JBOD No Input
• PSU JBODPSU FRU Disconnected
• PSU JBODPSU FRU Failed
• PSU JBODPSU FRU Prepare Failed
• PSU JBODPSU FRU Uninitialized
• PSU JBODPSU Firmware Invalid
• PSU JBODPSU Firmware Mismatch
• PSU JBODPSU Firmware Upgrading
• PSU JBODPSU System Disabled
• PSU JBODPSU User Disabled
• PSU NodePSU FRU Disconnected
• PSU NodePSU FRU Failed
81 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
• PSU NodePSU FRU Prepare Failed
• PSU NodePSU FRU Uninitialized
• PSU NodePSU Firmware Invalid
• PSU NodePSU Firmware Mismatch
• PSU NodePSU Firmware Upgrading
• PSU NodePSU No Input
• PSU NodePSU System Disabled
• PSU NodePSU User Disabled
• PSU Event
• SSD SSD Add Pending
• SSD SSD Assigning To RaidGroup
• SSD SSD Diagnostic Level 2 Unknown
• SSD SSD Diagnostic Level 3 Warning
• SSD SSD Diagnostic Level 4 Minor
• SSD SSD Diagnostic Level 5 Major
• SSD SSD Diagnostic Level 6 Critical
• SSD SSD Eject Pending
• SSD SSD Failed In RaidGroup
• SSD SSD FRU Disconnected
• SSD SSD FRU Failed
• SSD SSD FRU Prepare Failed
• SSD SSD FRU Uninitialized
• SSD SSD Firmware Invalid
• SSD SSD Firmware Mismatch
• SSD SSD Firmware Upgrading
• SSD SSD Limited Endurance
• SSD SSD Link1 Level 2 Unknown
• SSD SSD Link1 Level 3 Warning
• SSD SSD Link1 Level 4 Minor
• SSD SSD Link1 Level 5 Major
• SSD SSD Link1 Level 6 Critical
• SSD SSD Link2 Level 2 Unknown
• SSD SSD Link2 Level 3 Warning
• SSD SSD Link2 Level 4 Minor
• SSD SSD Link2 Level 5 Major
• SSD SSD Link2 Level 6 Critical
• SSD SSD Modify Pending
• SSD SSD Remaining Endurance None
82 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
• SSD SSD Not In RaidGroup
• SSD SSD Remove Pending
• SSD SSD System Disabled
• SSD SSD User Disabled
• SSD SSD Very Limited Endurance
• SSD Event
• Storage Controller Backend Storage Controller Error
• Storage Controller DED IPMI Port Down
• Storage Controller Disconnected From Node Manager
• Storage Controller Ethernet Port Down
• Storage Controller Ethernet Port Unknown
• Storage Controller Journal Dumping
• Storage Controller Journal Failback
• Storage Controller Journal Failed
• Storage Controller Journal Failover
• Storage Controller Journal Fault
• Storage Controller Management Port Half Duplex
• Storage Controller Module Failback
• Storage Controller Module Failed
• Storage Controller Module Failover
• Storage Controller Module Inactive
• Storage Controller Node Curt Level 2 Unknown
• Storage Controller Node Curt Level 3 Warning
• Storage Controller Node Curt Level 4 Minor
• Storage Controller Node Curt Level 5 Major
• Storage Controller Node Curt Level 6 Critical
• Storage Controller Node DIMM Level 2 Unknown
• Storage Controller Node DIMM Level 3 Warning
• Storage Controller Node DIMM Level 4 Minor
• Storage Controller Node DIMM Level 5 Major
• Storage Controller Node DIMM Level 6 Critical
• Storage Controller Node Discover BBU True
• Storage Controller Node Discover DAE Control
• Storage Controller Node Discover DAE
• Storage Controller Node Discover DAE PSU
• Storage Controller Node Discover IBSW
• Storage Controller Node Discover Localdisk
• Storage Controller Node Disk Limited Space
83 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
• Storage Controller Node Disk No Free Space
• Storage Controller Node Ethernet 100M Rate
• Storage Controller Node Ethernet 10M Rate
• Storage Controller Node Ethernet port Level 2 Unknown
• Storage Controller Node Ethernet port Level 3 Warning
• Storage Controller Node Ethernet port Level 4 Minor
• Storage Controller Node Ethernet port Level 5 Major
• Storage Controller Node Ethernet port Level 6 Critical
• Storage Controller Node Failed Stop
• Storage Controller Node Fan Level 2 Unknown
• Storage Controller Node Fan Level 3 Warning
• Storage Controller Node Fan Level 4 Minor
• Storage Controller Node Fan Level 5 Major
• Storage Controller Node Fan Level 6 Critical
• Storage Controller Node File Descriptors High
• Storage Controller Node FP Temperature High
• Storage Controller Node FP Temperature Invalid
• Storage Controller Node FP Temperature Warning
• Storage Controller Node Free RAM Low
• Storage Controller Node FRU Disconnected
• Storage Controller Node FRU Failed
• Storage Controller Node FRU Prepare Failed
• Storage Controller Node FRU Uninitialized
• Storage Controller Node Firmware Invalid
• Storage Controller Node Firmware Mismatch
• Storage Controller Node Firmware Upgrading
• Storage Controller Node IB1 Level 2 Unknown
• Storage Controller Node IB1 Level 3 Warning
• Storage Controller Node IB1 Level 4 Minor
• Storage Controller Node IB1 Level 5 Major
• Storage Controller Node IB1 Level 6 Critical
• Storage Controller Node IB1 Port Down
• Storage Controller Node IB1 Port Unknown
• Storage Controller Node IB2 Level 2 Unknown
• Storage Controller Node IB2 Level 3 Warning
• Storage Controller Node IB2 Level 4 Minor
• Storage Controller Node IB2 Level 5 Major
• Storage Controller Node IB2 Level 6 Critical
84 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
• Storage Controller Node IB2 Port Down
• Storage Controller Node IB2 Port Unknown
• Storage Controller Node Intsense Level 2 Unknown
• Storage Controller Node Intsense Level 3 Warning
• Storage Controller Node Intsense Level 4 Minor
• Storage Controller Node Intsense Level 5 Major
• Storage Controller Node Intsense Level 6 Critical
• Storage Controller Node IPMI port Disconnected
• Storage Controller Node IPMI port Invalid Wiring
• Storage Controller Node Manager Controlled Disconnect
• Storage Controller Node Orderly Stop
• Storage Controller Node Orderly Stopping
• Storage Controller Node RAM Too Low
• Storage Controller Node SAS1 3Gbps Rate
• Storage Controller Node SAS1 Connection Unknown DAE
• Storage Controller Node SAS1 Connection Wrong LCC
• Storage Controller Node SAS1 Connection Wrong LCC Port
• Storage Controller Node SAS1 Level 2 Unknown
• Storage Controller Node SAS1 Level 3 Warning
• Storage Controller Node SAS1 Level 4 Minor
• Storage Controller Node SAS1 Level 5 Major
• Storage Controller Node SAS1 Level 6 Critical
• Storage Controller Node SAS2 3Gbps Rate
• Storage Controller Node SAS2 Connection Unknown Dae
• Storage Controller Node SAS2 Connection Wrong Lcc
• Storage Controller Node SAS2 Connection Wrong Lcc Port
• Storage Controller Node SAS2 Level 2 Unknown
• Storage Controller Node SAS2 Level 3 Warning
• Storage Controller Node SAS2 Level 4 Minor
• Storage Controller Node SAS2 Level 5 Major
• Storage Controller Node SAS2 Level 6 Critical
• Storage Controller Node State Failed
• Storage Controller Node System Disabled
• Storage Controller Node Tech Tunnel Opened
• Storage Controller Node Temperature Level 2 Unknown
• Storage Controller Node Temperature Level 3 Warning
• Storage Controller Node Temperature Level 4 Minor
• Storage Controller Node Temperature Level 5 Major
85 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
• Storage Controller Node Temperature Level 6 Critical
• Storage Controller Node Unbalanced Failback Allowed
• Storage Controller Node Unorderly Stop
• Storage Controller Node Unorderly Stopping
• Storage Controller Node Upgrade In Progress
• Storage Controller Node User Disabled
• Storage Controller Node Voltage Level 2 Unknown
• Storage Controller Node Voltage Level 3 Warning
• Storage Controller Node Voltage Level 4 Minor
• Storage Controller Node Voltage Level 5 Major
• Storage Controller Node Voltage Level 6 Critical
• Storage Controller Node Wrong IB1 Port Connection
• Storage Controller Node Wrong IB1 Switch Connected
• Storage Controller Node Wrong IB2 Port Connection
• Storage Controller Node Wrong IB2 Switch Connected
• Storage Controller Remote Journal Dumping
• Storage Controller Remote Journal Failed
• Storage Controller SAS1 Port Down
• Storage Controller SAS2 Port Down
• Storage Controller Target FC Counter
• Storage Controller Target Not Found
• Storage Controller Target Add Pending
• Storage Controller Target Level 2 Unknown
• Storage Controller Target Level 3 Warning
• Storage Controller Target Level 4 Minor
• Storage Controller Target Level 5 Major
• Storage Controller Target Level 6 Critical
• Storage Controller Target Modify Pending
• Storage Controller Target Port State Down
• Storage Controller Target Remove Pending
• Storage Controller Upgrade Failed
• Storage Controller XEnv Failback
• Storage Controller XEnv Failed
• Storage Controller XEnv Failover
• Storage Controller XEnv Inactive
• Storage Controller Event
• Volume Small I/O Ratio High
• Volume Small I/O Ratio Low
86 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
• Volume Small I/O Ratio Medium
• Volume Un-align I/O Ratio High
• Volume Un-align I/O Ratio Low
• Volume Un-align I/O Ratio Medium
• Volume Volume Add Pending
• Volume Volume Modify Pending
• Volume Volume Remove Pending
• Volume Event
• X-Brick Failed Brick State
• X-Brick Foreign XtremApp SSD In Brick
• X-Brick Slot Error In Brick
• X-Brick Uninitialized SSD In Brick
• X-Brick Unsupported Disk In Brick
• X-Brick Event
• XtremIO Management Server Active Cluster Memory Recovery True
• XtremIO Management Server DAE Inaccessible
• XtremIO Management Server Data Consistency Error
• XtremIO Management Server Disconnected From System Manager
• XtremIO Management Server Disk Mount Failure
• XtremIO Management Server Double Node Failure
• XtremIO Management Server HA Failure
• XtremIO Management Server Hardware Failure
• XtremIO Management Server Inconsistent FC Tar Speed
• XtremIO Management Server Inconsistent SCSI
• XtremIO Management Server Insufficient UPS Protection
• XtremIO Management Server Notifier Disabled
• XtremIO Management Server Power Off Button Pressed
• XtremIO Management Server Restart Failure
• XtremIO Management Server Scheduler Disabled By User
• XtremIO Management Server Scheduler Last Activation Cluster Volumes Max Reached
• XtremIO Management Server Scheduler Last Activation Failed
• XtremIO Management Server Scheduler Last Activation Object Not Found
• XtremIO Management Server Scheduler Last Activation Cluster VSG Max Reached
• XtremIO Management Server Stopped Multiple Disk Failure
• XtremIO Management Server SW Failure
• XtremIO Management Server System CHAP init Missing Cluster Credentials
• XtremIO Management Server System CHAP init Missing Credentials
• XtremIO Management Server System Encrypt Failed
87 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
• XtremIO Management Server System Encrypt Started
• XtremIO Management Server System Encrypt Switch Incomplete
• XtremIO Management Server System Expansion Progress Yes
• XtremIO Management Server System Failed Stop
• XtremIO Management Server System Hardware Package Inconsistent
• XtremIO Management Server System in Failed State
• XtremIO Management Server System Orderly Stopping
• XtremIO Management Server System Shared Memory Inefficiency High
• XtremIO Management Server System Shared Memory - Inefficiency Medium
• XtremIO Management Server System Shared Memory Limited
• XtremIO Management Server System Shared Memory - No Free
• XtremIO Management Server System Shared Memory Very Limited
• XtremIO Management Server System Shared Memory - Limited Recoverable
• XtremIO Management Server System Shared Memory - No Free Recoverable
• XtremIO Management Server System Shared Memory Very Limited, Recoverable
• XtremIO Management Server System Shutdown Request
• XtremIO Management Server System Starting
• XtremIO Management Server System State Down
• XtremIO Management Server System State Unknown
• XtremIO Management Server System Stop Failed
• XtremIO Management Server System Stopped
• XtremIO Management Server System Stopping
• XtremIO Management Server System User Data SSD Space Limited
• XtremIO Management Server System User Data SSD Space - No Free
• XtremIO Management Server System User Data SSD Space Very Limited
• XtremIO Management Server System Unorderly Stopping
• XtremIO Management Server System Proactive Loading True
• XtremIO Management Server System Rollback Ongoing
• XtremIO Management Server System Upgrade Bring Up
• XtremIO Management Server System Upgrade Failed
• XtremIO Management Server System Upgrade Preparing
• XtremIO Management Server System Upgrade Waiting for System
• XtremIO Management Server UPS Failure
• XtremIO Management Server User Deactivated
• XtremIO Management Server User Physical Capacity High
• XtremIO Management Server User Physical Capacity Very High
• XtremIO Management Server VAAI TP Limit Threshold Exceeded
• XtremIO Management Server XMS Disk - Low Free Space
88 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
• XtremIO Management Server XMS Disk - No Free Space
• XtremIO Management Server XMS Second Disk - Low Free Space
• XtremIO Management Server XMS Second Disk - No Free Space
• XtremIO Management Server XMS Second Disk - Very Low Free Space
• XtremIO Management Server XMS Disk - Very Low Free Space
• XtremIO Management Server XMS Memory Full
• XtremIO Management Server XMS Memory Low
• XtremIO Management Server XMS Wrong CN True
• XtremIO Management Server Event
89 Blue Medora VMware vRealize Operations Management Pack for Dell EMC XtremIO User Guide
12. Appendix III: Capacity Definitions
The Management Pack uses the following capacity definitions, which help determine the value of Analysis Badges (refer to section “8. Analysis Badges”) within vRealize Operations. For more information on using Analysis Badges, refer to the VMware vRealize Operations online help.
Table 2: Capacity Definitions
CONTAINER USE IN WORKLOAD
Battery Backup Unit
vRealize Calculated Load Capacity yes
vRealize Calculated Uncharged Capacity yes
Cluster
vRealize Calculated IOPS Capacity yes
vRealize Calculated Logical Capacity yes
vRealize Calculated Physical Capacity yes
vRealize Calculated Shared Memory Capacity yes
vRealize Calculated Throughput Capacity yes
Data Protection Group
vRealize Calculated IOPS Capacity yes
vRealize Calculated Physical Capacity yes
vRealize Calculated Throughput Capacity yes
Host Interface
vRealize Calculated IOPS Capacity yes
vRealize Calculated Throughput Capacity yes
SSD
vRealize Calculated IOPS Capacity yes
vRealize Calculated Physical Capacity yes
vRealize Calculated Throughput Capacity yes
Volume
vRealize Calculated IOPS Capacity yes
vRealize Calculated Throughput Capacity yes
vRealize Calculated Volume Capacity yes
XtremIO Management Server
vRealize Calculated CPU Capacity yes
vRealize Calculated IOPS Capacity yes
vRealize Calculated Memory Capacity yes
vRealize Calculated Throughput Capacity yes
Copyright © 2016 Blue Medora Inc. All rights reserved. U.S. and international copyright and intellectual property laws protect this product. Blue Medora is a registered trademark or trademark of Blue Medora in the United States and/or other jurisdictions.
The XtremIO name and logo are trademarks or registered trademarks of Dell EMC in the United States and/or other jurisdictions. All other marks and names mentioned herein may be trademarks of their respective companies.
Blue Medora3225 N Evergreen Dr. NE Suite 103Grand Rapids, MI 49525
bluemedora.com
You can find the most up-to-date technical documentation on the Blue Medora support site at: http://support.bluemedora.com.
The Blue Medora website also provides the latest product updates. If you have comments about this documentation, submit your feedback to: [email protected].