28
DMP Plus Series / C V Models DMP Plus Series / C V AT Models Patton POTS Configuration Guide REVISION: 1.0.0 DATE: OCTOBER 16, 2020

VoIP Configuration Guide - Extron · 2020. 10. 16. · The Patton SmartNode default configuration has Interface Ethernet 0 (ETH0) set to DHCP from the factory. The attached configuration

  • Upload
    others

  • View
    15

  • Download
    0

Embed Size (px)

Citation preview

  • DMP Plus Series / C V Models DMP Plus Series / C V AT Models Patton POTS Configuration Guide

    REVISION: 1.0.0 DATE: OCTOBER 16, 2020

  • Revision Date: 10/16/2020

    Page 2 of 28

    DMP Plus Series C V / C V AT – Patton POTS

    Revision Log

    Date Version Notes Oct 16, 2020 1.0.0 Initial Release

  • Revision Date: 10/16/2020

    Page 3 of 28

    DMP Plus Series C V / C V AT – Patton POTS

    Table of Contents 1.0 Introduction ......................................................................................................................... 5

    1.1 Overview of setup ............................................................................................................ 5

    1.1.1 Features supported ................................................................................................... 5

    1.1.2 Features not supported ............................................................................................ 5

    1.1.3 DMP Plus Setup ......................................................................................................... 5

    1.1.4 Patton POTS interface ............................................................................................... 6

    1.1.5 Wiring ........................................................................................................................ 6

    2.0 Configuring Patton POTS interface for DMP Plus Series C V (AT) VoIP ............................... 7

    2.1 Ordering Information ....................................................................................................... 7

    2.1.1 Patton SN4112/JO/EUI - VoIP Gateway 2 FXO Ports ................................................ 7

    2.1.2 Firmware used during testing: R6.11 2019-07-02 ................................................... 7

    2.2 Setting IP address on Patton ............................................................................................ 7

    2.2.1 Setting the IP address via DataViewer ...................................................................... 7

    2.3 Upload configuration into Patton POTS interface ........................................................... 9

    2.3.1 Login to Webpage ..................................................................................................... 9

    2.3.2 Patton Firmware/Software ....................................................................................... 9

    2.4 Upload configuration File ............................................................................................... 11

    2.4.1 To restart / reload, select Reload in the lower left ................................................ 12

    2.4.2 If any changes are made, they will need to be saved to the startup-config .......... 12

    2.5 Adjust auto hang-up / Call disconnection ...................................................................... 13

    2.5.1 Adjust auto hang-up and Call disconnection if necessary ...................................... 13

    3.0 Configuring DMP Plus Series C V (AT) VoIP Lines .............................................................. 14

    3.1 Network Interface Configuration ................................................................................... 14

    3.2 Transport Configuration ................................................................................................. 16

    3.3 Line Registration ............................................................................................................. 17

    3.4 Codecs ............................................................................................................................ 18

    3.5 Dialing ............................................................................................................................. 19

    3.6 System Overview ............................................................................................................ 20

    3.7 Troubleshooting ............................................................................................................. 20

  • Revision Date: 10/16/2020

    Page 4 of 28

    DMP Plus Series C V / C V AT – Patton POTS

    Appendix A: Configuration Files – Attached to PDF ..................................................................... 21

    Appendix B: How to manually set the IP address of the Patton SN4112 ................................... 22

    Appendix C: How to import configuration into DMP Plus ............................................................ 23

    Appendix D: Patton RS-232 Cable wiring detail ............................................................................ 24

    Appendix E: Copy of DMP Plus VoIP Configuration ...................................................................... 25

    Appendix F: Copy of Patton configuration .................................................................................... 26

  • Revision Date: 10/16/2020

    Page 5 of 28

    DMP Plus Series C V / C V AT – Patton POTS

    1.0 Introduction

    This document provides essential instructions for configuring the VoIP lines of DMP Plus Series, C V and C V AT models, with the Patton SN 4110 Series FXO. DMP Plus Relates to the following products:

    • DMP 128 Plus C V / C V AT • DMP 128 FlexPlus C V AT • DMP 64 Plus C V / C V AT

    1.1 Overview of setup VoIP Line 1 in the DMP Plus will be directly connected to the LAN interface of the Patton POTS interface. This does not need to be connected to a network. The DMP Plus will not register to a call server or Patton POTS interface. The DMP Plus and Patton POTS interface need to be located on the same subnet / VLAN Features supported

    • POTS interface will support a single POTS line on FXO Port 0/0 • Hold is supported

    1.1.1 Features not supported • 3-Way calling is not supported • Hook Flash is not supported • VoIP Dialer in DSP Configurator Software will not work since the line does not

    register to a call server.

    1.1.2 DMP Plus setup • Firmware: 1.06.0000 or Higher • Line 1: Ext 1001 • LAN2 IP address: 192.168.1.254 / 255.255.255.0 • LAN2 port of the DMP Plus

    Figure 1 DMP 64 Plus C V AT – Rear

    Figure 2 DMP 128 Plus C V AT - Rear

    LAN 2

    LAN 2

  • Revision Date: 10/16/2020

    Page 6 of 28

    DMP Plus Series C V / C V AT – Patton POTS

    1.1.3 Patton POTS interface • LAN port • IP Address: 192.168.1.253 / 255.255.255.0 • Firmware: R6.11 2019-07-02

    1.1.4 Wiring • Using a CAT5/6 network cable

    o Directly connect LAN 2 of DMP Plus to o Patton 10/100 ENET port / ETH 0/0 port

    Figure 3 DMP 64 C V AT Plus Figure 4 Patton SN4112/JO/EUI

    • Connect the analog Telephone POTS line to the Voice Port FXO 0/0

    o Port 1

    Figure 5 Patton SN4112/JO/EUI – Rear Panel Figure 6 Analog Phone Line – POTS

    1

    2

  • Revision Date: 10/16/2020

    Page 7 of 28

    DMP Plus Series C V / C V AT – Patton POTS

    2.0 Configuring Patton POTS interface for DMP Plus Series C V (AT) VoIP This section will guide you through the setup of the Patton POTS interface.

    2.1 Ordering Information The Patton Smart Node VoIP Gateway has multiple different models. Note: When purchasing the Patton POTS interface, make sure to purchase the model with FXO ports. Units with FXS ports will not work.

    2.1.1 Patton SN4112/JO/EUI - VoIP Gateway 2 FXO Ports o Product page:

    https://www.patton.com/voip-gateway/sn4110/

    2.1.2 Firmware used during testing: R6.11 2019-07-02 • SN4110_H323_SIP_R6.11_2019-07-02 • Firmware can be downloaded at patton.com

    o https://www.patton.com/support/upgrades/index.asp?um=SmartNode%20411x

    2.2 Setting IP address on Patton The Patton SmartNode default configuration has Interface Ethernet 0 (ETH0) set to DHCP from the factory. The attached configuration (Patton_Config.cfg) needs to be uploaded via the internal webpage on the Patton SN4112/JO/EUI VoIP Gateway.

    2.2.1 Setting the IP address via DataViewer Utilizing the included console cable that comes with the Patton POTS interface:

    • Connect the RJ-45 to Port labeled “Console” on the front of the Patton • Connect the RS-232 DB-9 to your computer

    https://www.patton.com/voip-gateway/sn4110/https://www.patton.com/support/upgrades/index.asp?um=SmartNode%20411xhttps://www.patton.com/support/upgrades/index.asp?um=SmartNode%20411x

  • Revision Date: 10/16/2020

    Page 8 of 28

    DMP Plus Series C V / C V AT – Patton POTS

    • Using Extron DataViewer connect to the Patton POTS interface via RS-232 o Download the attached file “DataViewer Set Patton IP address.txt” from the PDF

    Refer to Appendix A to download the files from the PDF

    o Open Extron DataViewer

    o Click Connect from the toolbar File -> Connect (ALT+E)

    o Select the RS-232 Tab

    Setup the port: • Com Port (select COM port on your computer) • Baud Rate: 9600 • Parity Bit: None • Data Bit: 8 • Stop Bit: 1 • Handshake: None

    o Press OK/Enter until you see “login:”

    • Once connected to the Patton and you see login:

    • In DataViewer select “Run Script from the menu bar o Tools -> Send Script File ( ALT + F ) o Select DataViewer Set Patton IP address.txt and Click Open

    Refer to Appendix A to download the files from the PDF

    • The Script will set the IP address to o 192.168.1.253 / 255.255.255.0

    https://www.extron.com/product/software/dataviewerhttps://www.extron.com/product/software/dataviewer

  • Revision Date: 10/16/2020

    Page 9 of 28

    DMP Plus Series C V / C V AT – Patton POTS

    2.3 Upload configuration into Patton POTS interface After the IP address has been setup on the Patton POTS interface, the attached configuration file must be uploaded via the webpage interface.

    2.3.1 Login to Webpage • Connect to the internal Webpage via the IP address of the unit set in

    the previous step o http://192.168.1.253 o the factory defaults for logging in:

    login: administrator Password: (leave the password empty )

    2.3.2 Patton Firmware/Software • This configuration guide was developed using firmware R6.11

    o if firmware is up to date skip to 2.3.3 Upload configuration File • The Software/Firmware information is displayed on the main page

    when you log in:

    • If the software/Firmware needs to be updated: • First download the Software from patton.com:

    o https://www.patton.com/support/upgrades/index.asp?um=SmartNode%20411x • Connect to the webpage on the Patton POTS interface

    o http://192.168.1.253 o the factory defaults for logging in:

    login: administrator Password: (leave the password empty )

    • From the Patton webpage Select Import/Export, Upper Left corner

    o

    http://192.168.1.253/https://www.patton.com/support/upgrades/index.asp?um=SmartNode%20411xhttp://192.168.1.253/

  • Revision Date: 10/16/2020

    Page 10 of 28

    DMP Plus Series C V / C V AT – Patton POTS

    • Select Import Firmware • Follow the instructions below

    o Shutdown VoIP Gateways

    o Firmware upload

    o Once the VoIP Gateways are shut down the Download firmware dialog will appear o Select “Choose file” and select the downloaded ZIP file. o Select Import

    o Firmware will download and be programmed into the Patton POTS interface. o Once the firmware update is complete, the box will need to be Reload/Restarted before the

    update will take effect.

  • Revision Date: 10/16/2020

    Page 11 of 28

    DMP Plus Series C V / C V AT – Patton POTS

    2.4 Upload configuration File • If the firmware has been updated, verify the unit has been restarted • From the Patton webpage Select Import/Export, Upper Left corner

    o

    • Select Import Configuration, then click Choose file o Select the “Patton_Config.cfg” attached to this PDF document

    Refer to Appendix A to download the files from the PDF o Select Import

    • Once the File has been imported the Patton will need to be rebooted / reloaded

  • Revision Date: 10/16/2020

    Page 12 of 28

    DMP Plus Series C V / C V AT – Patton POTS

    2.4.1 To restart / reload, select Reload in the lower left

    2.4.2 If any changes are made, they will need to be saved to the startup-config The save button is located in the lower Left, right above Reload Any changes not saved will be lost when the unit is Reload

  • Revision Date: 10/16/2020

    Page 13 of 28

    DMP Plus Series C V / C V AT – Patton POTS

    2.5 Adjust auto hang-up / Call disconnection If the calls do not disconnect from the POTS line, the Disconnect signals may need to be adjusted. The screen below is configured for Loop Break

    2.5.1 Adjust auto hang-up and Call disconnection if necessary • Select FXO under ports • Then select IF_FXO_00

    o • Adjust Disconnect Signal section for POTS line

    o Battery Reversal – momentarily swaps DC polarity on the line o Loop Break – momentarily disconnects the line voltage

    Most commonly used method The Loop-break duration is set for 220 ms to 600 ms

    and can be adjusted if needed o Disconnect Tones – Specify the tones to end a call

    Not commonly used

    If any changes are made, you will need to select Apply and then Save

    • Save is located in the lower Left

    192.168.1.253

  • Revision Date: 10/16/2020

    Page 14 of 28

    DMP Plus Series C V / C V AT – Patton POTS

    3.0 Configuring DMP Plus Series C V (AT) VoIP Lines VoIP configuration of the DMP Plus Series is handled exclusively through a web interface, served from the device itself. The VoIP landing page is accessed through an address of the format - http://192.168.254.254/www/voip.html - where 192.168.254.254 in this example is the default IP address on LAN 1 of the DMP Plus Series device. Line 1 will be configured as a SIP to POTS connection

    3.1 Network Interface Configuration Need to make sure that the LAN 1 and LAN 2 IP subnets (IP address / Subnet) do not overlap. The default subnet mask on LAN 1 of 255.255.0.0 needs to be changed to 255.255.255.0 The LAN 1 IP interface will be used for Setup and control. These settings can be changed per your application.

    1. Click on the Network tab followed by Interface tab 2. Under the LAN 1 Network interface:

    a. IP address Mode: Static b. IP address: 192.168.254.254 c. Subnet Mask: 255.255.255.0 d. Gateway: 0.0.0.0

    3. Click Apply after making any changes a. The Network interface will restart the VoIP services on the device.

    4. After the network interface has restarted

    http://192.168.254.254/www/voip.html

  • Revision Date: 10/16/2020

    Page 15 of 28

    DMP Plus Series C V / C V AT – Patton POTS

    5. Under VoIP Interface select LAN 2

    a. The Default VoIP interface is LAN 1 and will need to be set to LAN 2

    6. Under the LAN 2 Network interface:

    a. IP address Mode: Static b. IP address: 192.168.1.254 c. Subnet Mask: 255.255.255.0 d. Gateway: 0.0.0.0

    7. Click Apply after making any changes a. The Network interface will restart the VoIP services on the device.

    Note: Make sure that the LAN 1 and LAN 2 IP subnets (IP address / Subnet) do not overlap

  • Revision Date: 10/16/2020

    Page 16 of 28

    DMP Plus Series C V / C V AT – Patton POTS

    3.2 Transport Configuration Click on the Transport tab to access signaling transport configuration. Check that the transport is set to UDP. In the event that changes need to be made, click Apply to commit any adjustments to the device.

  • Revision Date: 10/16/2020

    Page 17 of 28

    DMP Plus Series C V / C V AT – Patton POTS

    3.3 Line Registration Click on the Line 1 tab to be configured as part of the system.

    1) User Name: 1001

    2) Authentication Name: 1001

    3) Authentication Password: 1001

    4) Display Name: Optional. Specify an identifier for the line if required.

    5) Primary Proxy Name/IP: 192.168.1.253 a. IP address of the Patton POTS interface

    6) Primary Proxy Port: 5060

    7) Once the above settings have been entered, click the Apply button to save to the

    device.

    8) Click the Register button a. Note: the VoIP Line will not register to the Patton POTS interface

    The DMP Plus will always show the Patton as “Not Registered”

  • Revision Date: 10/16/2020

    Page 18 of 28

    DMP Plus Series C V / C V AT – Patton POTS

    3.4 Codecs The availability and priority of codecs may be changed from within the Audio tab. Codecs will only be available for use within phone calls if they are moved from the Available to the Assigned column. By default, G.711u and G.711a are assigned to the system. Codec assignment and priority can be set per line. The Patton POTS interface will only work with G.711u and G.711a Click the Apply button to commit any changes to the device.

  • Revision Date: 10/16/2020

    Page 19 of 28

    DMP Plus Series C V / C V AT – Patton POTS

    3.5 Dialing Use the Dialing tab to select Out of Band – RFC 2833 for the Patton POTS interface. Click Apply after selecting Out of Band – RFC 2833 DTMF signaling method for the line. This can be set per line.

  • Revision Date: 10/16/2020

    Page 20 of 28

    DMP Plus Series C V / C V AT – Patton POTS

    3.6 System Overview The Home tab is used to view a summary of Line configuration and call status. In the example below, Line 1 has a configuration but shows as not registered. The Patton POTS interface will not show as registered. Appearance-specific (caller-specific) details for active calls can be accessed by clicking on the corresponding Line entry. VoIP Dialer in DSP Configurator Software will not work since the line does not register to a call server.

    3.7 Troubleshooting In the event of a problem, review the following:

    • Verify the correct port is used on the DMP Plus o LAN 2 is used in the example above

    Figure 7 DMP 64 PLUS C V AT - Rear

    • Verify the IP addresses have been configured properly

    o DMP Plus LAN2: 192.168.1.254 o Patton POTS Interface: 192.168.1.253

  • Revision Date: 10/16/2020

    Page 21 of 28

    DMP Plus Series C V / C V AT – Patton POTS

    Appendix A: Configuration Files – Attached to PDF If needed, the configuration file “voipConfig.conf” is attached to the PDF

    • To access the file select “Attachments” from the left side bar – see figure A1 • Then save the attachment, before uploading to DMP Plus – see Figure A2 below

    Figure A1 Save Attachment Figure A2 Show Attachments

  • Revision Date: 10/16/2020

    Page 22 of 28

    DMP Plus Series C V / C V AT – Patton POTS

    Appendix B: How to manually set the IP address of the Patton SN4112 Login Accessing your SmartNode via the local console port (or via a Telnet session) causes the login screen to display. Type the factory default login: administrator and leave the password empty. Press the Enter key after the password prompt. login:administrator password: 172.16.40.1> After you have successfully logged in you are in the operator execution mode, indicated by > as command line prompt. With the commands enable and configure you enter the configuration mode. 172.16.40.1>enable 172.16.40.1#configure 172.16.40.1(cfg)# Changing the IP address Select the context IP mode to configure an IP interface. 172.16.40.1(cfg)#context ip router 172.16.40.1(ctx ip)[router]# Now you can set your IP address and network mask for the interface eth0. Within this example a class C network (192.168.1.0/24) is assumed. The IP address in this example is set to 192.168.1.253 (you should set this to an unused IP address on your network). 172.16.40.1(ctx-ip)[router]#interface eth0 172.16.40.1(if-ip)[eth0]#ipaddress 192.168.1.253 255.255.255.0 2002-10-29T00:09:40 : LOGINFO : Link down on interface eth0. 2002-10-29T00:09:40 : LOGINFO : Link up on interface eth0. 192.168.1.253(if-ip)[eth0]#

    Copy this modified configuration to your new start-up configuration. Upon the next start-up the system will initialize itself using the modified configuration. 192.168.1.253 (if-ip)[eth0]#copy running-config startup-config 172.16.1.99(if-ip)[eth0]# The SmartNode can now be connected with your network.

  • Revision Date: 10/16/2020

    Page 23 of 28

    DMP Plus Series C V / C V AT – Patton POTS

    Appendix C: How to import configuration into DMP Plus

    1. Navigate to the DMP Plus Series VoIP configuration webpage and click on the System tab.

    2. Under Import System Configuration, click the Browse button to locate the

    voipConfig.conf file attached to this PDF i. Refer to Appendix A to download the files from the PDF

    3. Click the Import button to update the DMP Plus Series with the system configuration.

    4. A notification will appear once the settings have applied successfully.

  • Revision Date: 10/16/2020

    Page 24 of 28

    DMP Plus Series C V / C V AT – Patton POTS

    Appendix D: Patton RS-232 Cable wiring detail The Patton POTS interface come with a RJ-45 to DB-9 RS-232 cable, Patton Model 16F-894 Below is the wiring detail for the cable:

    b RJ-45

    RJ-45 Function DB-9 F 1 RI 6 2 CD 1 3 DTR 4 4 GND 5 5 RX 2 6 Tx 3 7 CTS 8 8 RTS 7

  • Revision Date: 10/16/2020

    Page 25 of 28

    DMP Plus Series C V / C V AT – Patton POTS

    Appendix E: Copy of DMP Plus VoIP Configuration {"network":{"voip_interface":2,"vlan_id":0,"dhcp_mode":0,"ip_addr":"192.168.1.254","netmask":"255.255.255.0","gateway":"0.0.0.0","dns1":"","dns2":"","pcp":3,"dscp_sip":24,"dscp_rtp":46,"lldp_med_enabled":0,"lldp_vlan_id_enabled":1,"lldp_pcp_enabled":1,"lldp_dscp_enabled":1,"lldp_location_enabled":1,"lldp_inventory_enabled":0,"street":"","building":"","city":"","state":"","zip":"","country":"","device_id":"","local_mode":"default","user_local_cert_file":"","user_local_key_file":"","server_certs":[],"server_cas":[],"tls_mode":"alwaysallow","sip_transport":"udp","sipport":5060,"srtprequire":false,"rtcpenable":true,"reg_default_time":3600,"registration_fail_retry_count":0,"registration_fail_retry_delay":600,"rtpstartport":50000,"rtpendport":50999,"sipkeepaliveenabled":true,"sip_outgoing_termination_use_cancel_enable":false,"sip_outbound_as_route_enable":true,"sip_reject_username_account_destination_mismatch":false,"sip_local_port_increased_for_users_enable":true,"single_codec_mode":"inactive","natmode":"disable","stunserveripaddress":"","stunserverport":-1,"turnserveripaddress":"","turnserverport":-1,"turnserverusername":"","turnserveruserpassword":""},"users":[{"id":"line1","username":"1001","displayname":"DMP PLUS","authusername":"1001","registrar":"192.168.1.253","registrarport":"5060","codecs":["g711u","g711a"],"autoanswer":0,"answer_delay":3,"dtmf_mode":"rfc2833"}]}

  • Revision Date: 10/16/2020

    Page 26 of 28

    DMP Plus Series C V / C V AT – Patton POTS

    Appendix F: Copy of Patton configuration

    #----------------------------------------------------------------# # # # SN4112/JO/EUI # # R6.11 2019-07-02 H323 SIP FXS FXO # # 2020-09-30T09:57:04 # # SN/00xxxxxxxxxx # # Generated configuration file # # # #----------------------------------------------------------------# cli version 3.20 clock local default-offset -04:00 dns-client server 4.2.2.2 webserver port 80 language en sntp-client sntp-client server primary 132.163.97.4 port 123 version 4 system ic voice 0 profile ppp default profile call-progress-tone defaultDialtone play 1 1000 350 -13 440 -13 profile call-progress-tone defaultAlertingtone play 1 1000 440 -19 480 -19 pause 2 3000 profile call-progress-tone defaultBusytone play 1 500 480 -24 620 -24 pause 2 500 profile call-progress-tone defaultReleasetone play 1 250 480 -24 620 -24 pause 2 250 profile call-progress-tone defaultCongestiontone play 1 250 480 -24 620 -24 pause 2 250 profile voip default codec 1 g711ulaw64k rx-length 20 tx-length 20 no-silence-suppression codec 2 g711alaw64k rx-length 20 tx-length 20 no-silence-suppression profile pstn default profile sip default no autonomous-transitioning profile aaa default

  • Revision Date: 10/16/2020

    Page 27 of 28

    DMP Plus Series C V / C V AT – Patton POTS

    method 1 local method 2 none context ip router interface eth0 ipaddress 192.168.1.253 255.255.255.0 tcp adjust-mss rx mtu tcp adjust-mss tx mtu context ip router route 0.0.0.0 0.0.0.0 192.168.1.1 1 context cs switch no digit-collection timeout routing-table called-e164 RT_from_FXO_00 route default dest-interface IF_SIP MAP1001 routing-table called-e164 RT_from_FXO_01 route default dest-interface IF_SIP MAP1002 mapping-table called-e164 to called-e164 MAP1001 map default to 1001 mapping-table called-e164 to called-e164 MAP1002 map default to 1002 interface sip IF_SIP bind context sip-gateway GW_SIP route call dest-service FXO-HUNT-OUT remote 192.168.1.254 early-connect interface fxo IF_FXO_00 route call dest-table RT_from_FXO_00 disconnect-signal loop-break ring-number on-caller-id dial-after dial-tone interface fxo IF_FXO_01 route call dest-table RT_from_FXO_01 disconnect-signal loop-break ring-number on-caller-id dial-after dial-tone service hunt-group FXO-HUNT-OUT drop-cause normal-unspecified drop-cause no-circuit-channel-available drop-cause network-out-of-order drop-cause temporary-failure drop-cause switching-equipment-congestion drop-cause access-info-discarded drop-cause circuit-channel-not-available drop-cause resources-unavailable

  • Revision Date: 10/16/2020

    Page 28 of 28

    DMP Plus Series C V / C V AT – Patton POTS

    drop-cause user-busy drop-cause destination-out-of-order route call 1 dest-interface IF_FXO_00 route call 2 dest-interface IF_FXO_01 context cs switch no shutdown context sip-gateway GW_SIP interface IF_GWSIP bind interface eth0 context router port 5060 context sip-gateway GW_SIP no shutdown port ethernet 0 0 medium auto encapsulation ip bind interface eth0 router no shutdown port fxo 0 0 use profile fxo us encapsulation cc-fxo bind interface IF_FXO_00 switch no shutdown port fxo 0 1 use profile fxo us encapsulation cc-fxo bind interface IF_FXO_01 switch no shutdown

    1.0 Introduction1.1 Overview of setup1.1.1 Features not supported1.1.2 DMP Plus setup1.1.3 Patton POTS interface1.1.4 Wiring

    1.2

    2.0 Configuring Patton POTS interface for DMP Plus Series C V (AT) VoIP2.1 Ordering Information2.1.1 Patton SN4112/JO/EUI - VoIP Gateway 2 FXO Ports2.1.2 Firmware used during testing: R6.11 2019-07-02

    2.2 Setting IP address on Patton2.2.1 Setting the IP address via DataViewer

    2.3 Upload configuration into Patton POTS interface2.3.1 Login to Webpage2.3.2 Patton Firmware/Software

    2.4 Upload configuration File2.4.1 To restart / reload, select Reload in the lower left2.4.2 If any changes are made, they will need to be saved to the startup-config

    2.5 Adjust auto hang-up / Call disconnection2.5.1 Adjust auto hang-up and Call disconnection if necessary

    3.0 Configuring DMP Plus Series C V (AT) VoIP Lines3.1 Network Interface Configuration3.2 Transport Configuration3.3 Line Registration3.4 Codecs3.5 Dialing3.6 System Overview3.7 TroubleshootingAppendix A: Configuration Files – Attached to PDFAppendix B: How to manually set the IP address of the Patton SN4112

    Appendix C: How to import configuration into DMP PlusAppendix D: Patton RS-232 Cable wiring detailAppendix E: Copy of DMP Plus VoIP ConfigurationAppendix F: Copy of Patton configurationAppendix F: Copy of Patton configuration

    // ==============================================================// DATAVIEWER SCRIPTING// ==============================================================// FILE NAME:Patton.txt// DEVICE NAME:Patton// MODEL NAME:MODEL# SN4112 (model number: SN4112/JO/EUI)// MODEL# SN4114 (model number: SN4114/JO/EUI)

    // CONNECTION SETTINGS TYPES:// Baud: 9600// Bits: 8// Parity: None// Stop Bits: 1// Flow Control: None//// NOTES// 1: POWER ON DEVICE // 2: Connect to Console Port// 3: Set RS-232 to Connections settings above: 9600, 8, N, 1, None//// ==============================================================// MANDATORY COMMANDS - DO NOT CHANGE// ==============================================================CLEARGLOBALWAIT=5000LOGFILE=C:\ProgramData\Extron\DataViewer\Patton_MODEL#.log//HEXTIMESTAMPBEGIN

    SISC=%0DWAIT=500SISC=%0DWAIT=500SISC=administrator%0DWAIT=500SISC=%0DWAIT=500SISC=%0DWAIT=500SISC=enable%0DWAIT=500SISC=configure%0DWAIT=500SISC=context ip router%0DWAIT=500SISC=interface eth0%0DWAIT=500// =============================================================// Sets IP address to 192.168.1.253 255.255.255.0// =============================================================

    SISC=ipaddress 192.168.1.253 255.255.255.0%0DWAIT=5000WAIT=5000WAIT=5000WAIT=5000WAIT=5000SISC=copy running-config startup-config%0DWAIT=500SISC=%0DSISC=exit%0DWAIT=500SISC=exit%0DWAIT=500SISC=reload%0DWAIT=500SISC=yes%0DWAIT=500SISC=%0DWAIT=500END

    #----------------------------------------------------------------## ## SN4112/JO/EUI ## R6.11 2019-07-02 H323 SIP FXS FXO ## 2020-09-30T09:57:04 ## SN/00XXXXXXXXXX ## Generated configuration file ## ##----------------------------------------------------------------#

    cli version 3.20clock local default-offset -04:00dns-client server 4.2.2.2webserver port 80 language ensntp-clientsntp-client server primary 132.163.97.4 port 123 version 4

    system

    ic voice 0

    profile ppp default

    profile call-progress-tone defaultDialtone play 1 1000 350 -13 440 -13

    profile call-progress-tone defaultAlertingtone play 1 1000 440 -19 480 -19 pause 2 3000

    profile call-progress-tone defaultBusytone play 1 500 480 -24 620 -24 pause 2 500

    profile call-progress-tone defaultReleasetone play 1 250 480 -24 620 -24 pause 2 250

    profile call-progress-tone defaultCongestiontone play 1 250 480 -24 620 -24 pause 2 250

    profile voip default codec 1 g711ulaw64k rx-length 20 tx-length 20 no-silence-suppression codec 2 g711alaw64k rx-length 20 tx-length 20 no-silence-suppression

    profile pstn default

    profile sip default no autonomous-transitioning

    profile aaa default method 1 local method 2 none

    context ip router

    interface eth0 ipaddress 192.168.1.253 255.255.255.0 tcp adjust-mss rx mtu tcp adjust-mss tx mtu

    context ip router route 0.0.0.0 0.0.0.0 192.168.1.1 1

    context cs switch no digit-collection timeout

    routing-table called-e164 RT_from_FXO_00 route default dest-interface IF_SIP MAP1001

    routing-table called-e164 RT_from_FXO_01 route default dest-interface IF_SIP MAP1002

    mapping-table called-e164 to called-e164 MAP1001 map default to 1001

    mapping-table called-e164 to called-e164 MAP1002 map default to 1002

    interface sip IF_SIP bind context sip-gateway GW_SIP route call dest-service FXO-HUNT-OUT remote 192.168.1.254early-connect

    interface fxo IF_FXO_00 route call dest-table RT_from_FXO_00 disconnect-signal loop-break ring-number on-caller-id dial-after dial-tone

    interface fxo IF_FXO_01 route call dest-table RT_from_FXO_01 disconnect-signal loop-break ring-number on-caller-id dial-after dial-tone

    service hunt-group FXO-HUNT-OUT drop-cause normal-unspecified drop-cause no-circuit-channel-available drop-cause network-out-of-order drop-cause temporary-failure drop-cause switching-equipment-congestion drop-cause access-info-discarded drop-cause circuit-channel-not-available drop-cause resources-unavailable drop-cause user-busy drop-cause destination-out-of-order route call 1 dest-interface IF_FXO_00 route call 2 dest-interface IF_FXO_01

    context cs switch no shutdown

    context sip-gateway GW_SIP

    interface IF_GWSIP bind interface eth0 context router port 5060

    context sip-gateway GW_SIP no shutdown

    port ethernet 0 0 medium auto encapsulation ip bind interface eth0 router no shutdown

    port fxo 0 0 use profile fxo us encapsulation cc-fxo bind interface IF_FXO_00 switch no shutdown

    port fxo 0 1 use profile fxo us encapsulation cc-fxo bind interface IF_FXO_01 switch no shutdown

    {"network":{"voip_interface":2,"vlan_id":0,"dhcp_mode":0,"ip_addr":"192.168.1.254","netmask":"255.255.255.0","gateway":"0.0.0.0","dns1":"","dns2":"","pcp":3,"dscp_sip":24,"dscp_rtp":46,"lldp_med_enabled":0,"lldp_vlan_id_enabled":1,"lldp_pcp_enabled":1,"lldp_dscp_enabled":1,"lldp_location_enabled":1,"lldp_inventory_enabled":0,"street":"","building":"","city":"","state":"","zip":"","country":"","device_id":"","local_mode":"default","user_local_cert_file":"","user_local_key_file":"","server_certs":[],"server_cas":[],"tls_mode":"alwaysallow","sip_transport":"udp","sipport":5060,"srtprequire":false,"rtcpenable":true,"reg_default_time":3600,"registration_fail_retry_count":0,"registration_fail_retry_delay":600,"rtpstartport":50000,"rtpendport":50999,"sipkeepaliveenabled":true,"sip_outgoing_termination_use_cancel_enable":false,"sip_outbound_as_route_enable":true,"sip_reject_username_account_destination_mismatch":false,"sip_local_port_increased_for_users_enable":true,"single_codec_mode":"inactive","natmode":"disable","stunserveripaddress":"","stunserverport":-1,"turnserveripaddress":"","turnserverport":-1,"turnserverusername":"","turnserveruserpassword":""},"users":[{"id":"line1","username":"1001","displayname":"DMP PLUS","authusername":"1001","registrar":"192.168.1.253","registrarport":"5060","codecs":["g711u","g711a"],"autoanswer":0,"answer_delay":3,"dtmf_mode":"rfc2833"}]}