W-H 1000 SYSTEMWall cladding
Metal product
APPLICATION AREA
Acoustic and architectural design elements for market segments such as office, education, transportation etc., can be used for column claddings and bulkheads.
BENEFITS
n Variety of customised design solutionsn Impressive visual appearance n Complete acoustic wall solutionn Large module sizes with upright and reclined panel optionsn Easily assembled and demountedn Can be used as a magnetic board in office and education
environments
MAINTENANCE AND ENVIRONMENT
They are washable, making them easy to clean. Armstrong´s dirt-repelling powder coating has proven itself to be an indestructible surface finish for many decades. The solvent-free production process also makes our wall claddings innocuous from an ecological and health-related viewpoint.
QUALITY AND SERVICE
Armstrong´s production facilities guarantee optimal capacity and the remarkably flexible production of wall cladding. Efficiently-organised processes, continuous quality management and a global network of subsidiaries and distribution partners ensure orders are delivered on time.
PROJECT: Learning Commons Building - Manchester University (UK) :::::::: ARCHITECT: Sheppard Robson PROJECT: University of Texas at San Antonio, Multidisciplinary Studies Building :::::::: ARCHITECT: Alvidrez Architecture Inc., San Antonio, TX
:::: 3
WALL CLADDING SYSTEM W-H 1000
SPECIFICATION
System Hook-on solution with rectangular panels
Square edged
With 5 mm black gasket and plastic spacer on one short
and one long side
Offset distance standard 60 +10/-15 mm
Acoustical Standard with black acoustic fleece
treatment (further inlays on request)
Dimension Type A Length 600 – 1300 mm / Width 275 – 1000 mm
Type B Length 1301 – 2500 mm / Width 275 – 1000 mm
Type C Length 2501 – 3000 mm / Width 275 – 1000 mm
Type D Length 600 – 3000 mm / Width 275 – 1000 mm
Edge detail all around 30 mm for standard panels
40 different types of panels available on request
Grid Horizontal direction
C-wall profile fixed with wall anchors to the wall
CHOICE OF PANEL TYPE
STANDARD PERFORATION PATTERNS
ACOUSTIC PERFORMANCE
Metal wall cladding products have been tested for their acoustic performance of sound absorption. All perforated products can be supplied with a varietyof factory fitted acoustic infill options. Please contactus for more information.
THERMAL CONDUCTIVITY
(λ) W/mK50.0 : Steel0.04 : Acoustic fleece
HUMIDITY EXPOSURE
Not greater than 70% RH @ 16˚-23˚C for long termexposure. Not greater than 95% RH for short termexposure during building site installation.
SERVICES INTEGRATION
Metal panels can be supplied with factory produced cut outs and apertures for the integration of building services equipment.
CLEANING
Dust should be removed from the painted surfaceby wiping with a clean soft cloth. More stubbornmarks should be removed with a mild householddetergent in warm water. Excessive use of watershould be avoided. The use of abrasive cleaners orscrubbing of the painted surface is notrecommended.
COLOUR
Standard colourRAL 9010 white (20% gloss), optional Global White (12% gloss)
Special coloursOther RAL and NCS colours available on request
QUALITY STANDARD
Armstrong is a certified EN ISO 9001:2008 Quality Assumed Manufacturer. All wall cladding and grid items are manufactured to tolerances and quality standards as Armstrog ceilings. Where differences exists between this and any expressed or implied architectural specificaitons or requirements then Armstrong’s manufacturing standards will prevail unless stated otherwise.
ENVIRONMENTAL
Our metal panels have an average of up to 30% recycling content.Our European manufacturing plants are certified to:EN ISO 9001:2008ISO 14001:2004 + Cor. 1:2009.
Armstrong is a member of TAIM (Technical Association of Industrial Metal Ceilings).
Microperforation Rd 1522Hole diameter: 1.5 mm Open area: 22%
Standard PerforationRg 2516Hole diameter: 2.5 mm Open area: 16%
RAL 9010 Global White RAL 9006 RAL 9007
executiontype
D01 - D10
executiontype
B01 - B10
executiontype
A01 - A10
executiontype
C01 - C10
panel alignment
panel dimensionpanel dimension
upright reclined
- 2500 mm
type A type B
- 1300 mm
type C type D
- 3000 mm
on request
specialsizes
- 3000 mm
on request
specialsizes
:::: 5
6 ::::
PROJECT: Learning Commons Building - Manchester University (UK) :::::::: ARCHITECT: Sheppard Robson
standard execution one single line upright
one single line reclined one single panel
standard execution one single line upright
one single line reclined one single panel
standard execution one single line upright
one single line reclined one single panel
Panels type A01 - A10length A: min. 600 / max. 1300 mmwidth B: min. 275 / max. 1000 mm
Panels type B01 - B10length A: min. 1301 / max. 2500 mmwidth B: min. 275 / max. 1000 mm
Panels type C01 - C10length A: min. 2501 / max. 3000 mmwidth B: min. 275 / max. 1000 mm
Panels type D01 - D10length A: min. 600 / max. 3000 mmwidth B: min. 275 / max. 1000 mm
standard execution one single line upright
one single line reclined one single panel
OVERVIEW AND CONSTRUCTION
:::: 9
PROJECT: Dubai International Airport. Dubai (UAE) :::::::: ARCHITECT: Aéroport de Paris (ADPi), Paris, France
Detail A connector for C-wall profile
C-wall profile length = 3
‚000 mm
Detail B wall anchor-installation
Detail C wall anchor installed
Detail D direct installation to wall (optional)
Detail E supporting bracket
4 x self drilling screweco-drill 3.5 x 9.5 mm
wall anchor for C-wall profile
wall anchor forC-wall profile
C-wall profile
2 x supporting bracket forC-wall profile
Raw wall
Raw wall
Raw wall
standard panelW-H 1000
supporting bracket for C-wall profile
wall anchor forC-wall profile
C-wall profile
C-wall profile
C-wall profileItem No. Designation
BPM 311200 plastic dowel UX-10
BPM 311201 screw for plastic dowel UX-10
BPM 315620 C-wall profile
BPM 315629 connector for C-wall profile
BPM 315628 supporting bracket for C-wall profile
BPM 315621 wall anchor for C-wall profile
BPM 311191 self drilling screw eco-drill 3.5 x 9.5 mm
raw wall
C-wall profile connector for C-wall profile
8 x self drilling screweco-drill 3.5 x 9.5 mm
C-wall profile
gasket 5 mm blackalong and across
plastic dowel UX-10 and screw
plastic dowel UX-10 and screw
PERSPECTIVE VIEW
:::: 1110 ::::
Type C01length A: min. 2‘501 / max. 3‘000 mmwidth B: min. 275 / max. 1‘000 mm4 suspension points on each long sideof the panel, upright misplaced
Type B01length A: min. 1‘301 / max. 2‘500 mmwidth B: min. 275 / max. 1‘000 mm3 suspension points on each long sideof the panel, upright misplaced
Type D01length A: min. 600 / max. 3‘000 mmwidth B: min. 275 / max. 1‘000 mm2 suspension points on each short sideof the panel, reclined misplaced
WALL PANEL TYPES
Type A01length A: min. 600 / max. 1‘300 mmwidth B: min. 275 / max. 1‘000 mm2 suspension points on each long sideof the panel, upright misplaced
:::: 1312 ::::
Detail F connection to the ceiling Detail G visible connection to the top Detail H connection to the top with profile
C-wall profile
wall anchor forC-wall profile
end profile
C-wall profile
wall anchor forC-wall profile
C-wall profile
wall anchor forC-wall profile
Detail J connection to the floor Detail K visible connection to the bottom
Detail L connection to the bottom with angle
C-wall profile
wall anchor forC-wall profile
C-wall profile
wall anchor forC-wall profile
C-wall profile
wall anchor forC-wall profile
angle
Detail M connection to the door frame Detail N connection to lintel
Detail I connection to the windowsill
windowsill
C-wall profile
wall anchor forC-wall profile
C-wall profile
wall anchor forC-wall profile
C-wall profile
wall anchor forC-wall profile
doorframe
door leaf
lintel (metal plate)
Detail O lateral connection to the wall Detail P visible lateral connection
Detail Q lateral connection to the door frame Detail R inside corner with gap
Detail S outside corner with special panel
wall anchor for C-wall profile
C-wall profile
supporting bracket for C-wall profile
wall anchor forC-wall profile
C-wall profiledoor frame
door leaf
special panel
wall anchor for C-wall profile
C-wall profile
supporting bracketfor C-wall profile
wall anchor for C-wall profile
C-wall profile
supporting bracket for C-wall profile
wall anchor for C-wall profile
C-wall profile
supporting bracket for C-wall profile
VERTICAL HORIZONTAL
CONCLUSION DETAILS
14 ::::
PROJECT: Dubai International Airport. Dubai (UAE) :::::::: ARCHITECT: Aeroport de Paris (ADPi), Paris, France
Starting position
n installed wall claddingn each panel can be dismounted
separately without a tool, starting from the top
n panels should only be touched with clean gloves
Step 1
n the panel must be lifted up vertically at min. 10 mm
n keep attention to existing installations
Step 2
n the panel can be removedn store the panel carefully
PANEL DISMOUNTING