Upload
others
View
16
Download
0
Embed Size (px)
Citation preview
Water Analysis
Water analysis made easy VISOCOLOR® tests for water analysis•Various measuring methods and detection principles for many parameters•Visual and photometric determination•Reagent cases with individual combinations of different test kitsVISO
CO
LOR
® •
VISO
CO
LOR
®
www.mn-net.com
www.mn-net.comMACHEREY-NAGEL GmbH & Co. KG · Neumann-Neander-Str. 6–8 · 52355 Düren · GermanyFrance:MACHEREY-NAGEL EURLTel.: +33 388 68 22 68Fax: +33 388 51 76 88E-mail: [email protected]
Switzerland:MACHEREY-NAGEL AGTel.: +41 62 388 55 00Fax: +41 62 388 55 05E-mail: [email protected]
Germanyand international:Tel.: +49 24 21 969-0Fax: +49 24 21 969-199E-mail: [email protected]
MACHEREY-NAGEL
EN ISO 9001: 2008CERTIFIED
USA:MACHEREY-NAGEL Inc.Tel.: +1 484 821 0984Fax: +1 484 821 1272E-mail: [email protected]
VISOCOLOR ®
www.mn-net.com www.mn-net.com
VISOCOLOR® test kits VISOCOLOR® tests are compact and flexible test kits, which allow a chemical analysis without additional accesso-riesandwithout theneed foranypriorexperience.Theyaresuitable foranalysis in labs, inschoolordirectlyon-site. MACHEREY-NAGELoffersthreeproductlineswithdifferentaccuracies,precisionsandsensitivitiesforuniversalusede-pendingontheanalyticalrequirement.Foreachproductlinetherearecolorimetricandtitrimetricmeasuringmethodstodetermineallimportantwaterandwastewaterparameters.TheVISOCOLOR® test kits can be sold individually or in stable reagentcasesasportablelaboratories.
Convenient handling•Simple chemical-analytical methods•Instructions in different languages and with pictograms for safe and simple test performance•Color-codedreagentbottlesforclearidentificationofreagents•Fast-dissolvingreagentssavetimeandfacilitatethedailywork
Reliable analysis•Reactionprinciplesbasedoninternationallyacknowledgedregulations(DIN,EN,ISO)•Maximumsafetyfortheuserandeasydisposal•Low susceptibility to interferences •Additional increase of accuracy by photometric determination of VISOCOLOR® ECO testswiththephotometersPF-12andPF-3
Unique quality•VISOCOLOR® color charts are setted on the original colors of freshly produced
standard solutions•Finestmeasurementgraduationsbytruecolorprinting•Precision and reproducibility by high printing quality
VISOCOLOR® alphaEasy and compact•Cost-efficient•Handy packages•Multicomponent reagents for reducing of required amount of reagent
Colorimetry with color chart
Fillthesample Add reagent Mix Analyze
Titration with drop counting
Fillthesample Add reagent Color change
Countthedrops:1 =1measuringunit
VISOCOLOR ®
www.mn-net.com www.mn-net.com
VISOCOLOR® test kits VISOCOLOR® tests are compact and flexible test kits, which allow a chemical analysis without additional accesso-riesandwithout theneed foranypriorexperience.Theyaresuitable foranalysis in labs, inschoolordirectlyon-site. MACHEREY-NAGELoffersthreeproductlineswithdifferentaccuracies,precisionsandsensitivitiesforuniversalusede-pendingontheanalyticalrequirement.Foreachproductlinetherearecolorimetricandtitrimetricmeasuringmethodstodetermineallimportantwaterandwastewaterparameters.TheVISOCOLOR® test kits can be sold individually or in stable reagentcasesasportablelaboratories.
Convenient handling•Simple chemical-analytical methods•Instructions in different languages and with pictograms for safe and simple test performance•Color-codedreagentbottlesforclearidentificationofreagents•Fast-dissolvingreagentssavetimeandfacilitatethedailywork
Reliable analysis•Reactionprinciplesbasedoninternationallyacknowledgedregulations(DIN,EN,ISO)•Maximumsafetyfortheuserandeasydisposal•Low susceptibility to interferences •Additional increase of accuracy by photometric determination of VISOCOLOR® ECO testswiththephotometersPF-12andPF-3
Unique quality•VISOCOLOR® color charts are setted on the original colors of freshly produced
standard solutions•Finestmeasurementgraduationsbytruecolorprinting•Precision and reproducibility by high printing quality
VISOCOLOR® alphaEasy and compact•Cost-efficient•Handy packages•Multicomponent reagents for reducing of required amount of reagent
VISOCOLOR® ECOAccurate and precise•Sharpcolorchangeduetoseparateindicatorandtitrationsolution•Compensationofturbidityandcolors•Cost-efficientrefillpacksavailable
Colorimetry with color chart
Fillthesample Add reagent Mix Wait
Analyze
Titration with drop counting
Fillthesample
Add indicator
Add titration solu-tionandmix
Color change
Countthedrops:1 =1measuringunit
VISOCOLOR® HEHighest sensitivity and accuracy•Highestsensitivity(10to100times)•Narrowgradationandnarrowlygraduatedsyringe•Compensationofturbidityandcolors•Cost-efficientrefillpacksavailable
Colorimetry with color comparison disc
Fillsample
A B
Add reagent
A B
Mix
AB
Wait
Analyze
Titration with graduated syringe
Fillthesample Add indicator Titrationsolution Color change
Analyze
Evaluation with photometer PF-12 & PF-3
VISOCOLOR ®Innen Headline 16pt Orange_WeißHinterlegtInnen Fließtext 10ptSchwarz
www.mn-net.com www.mn-net.com
VISOCOLOR® reagent casesInfinite options•Rugged cases with premium foam inlays•WithandwithoutphotometerPF-12•Pre-packed or empty cases for individual solutions
VISOCOLOR® reagent case without photometerVISOCOLOR® reagent case for soil analysis REF 931 601• Incl.allreagents,instrumentsandadditionaltoolstoproduce soilextractsanddeterminesoilstructure, potassium,pH,phosphate,ammonium,nitriteandnitrate
VISOCOLOR® ECO reagent case REF 931 301•Fordeterminationofammonium,carbonatehardness,totalhardness, nitrate,nitrite,pHandphosphate
VISOCOLOR® ECO reagent case (empty) REF 931 303•Forindividualequipmentwith
8 different VISOCOLOR® ECO testsVISOCOLOR® reagent case REF 931 304•Fordeterminationofalkalinity,ammonium,totalhardness,nitrite,pH,phosphate, oxygen,temperature
VISOCOLOR® reagent case (empty) REF 931 305•ForindividualequipmentwithVISOCOLOR® ECOtests,VISOCOLOR® HEtests,
VISOCOLOR® alphatests,pHindicatorpapers,pHfixteststrips,qualitativeand semi-qualitative test papers and test strips
VISOCOLOR® reagent case with photometer PF-12VISOCOLOR® reagent case “Environmental analysis” REF 914 303•Fordeterminationofammonium,carbonatehardness,iron,totalhardness, nitrate,nitrite,pH,phosphateincl.photometerPF-12
VISOCOLOR® reagent case with photometer PF-12 REF 914 301•ForindividualequipmentwithVISOCOLOR® ECOtests,
VISOCOLOR® HEtests,VISOCOLOR® alphatests, pHindicatorpapers,pHfixteststrips,qualitativeand semi-qualitative test papers and test strips
Slip lid tubes for qualitative test papers and indicator papers withour color scale
Aluminium tubes and snap-on lids for semi-quantitative and qualitativetestpapers,teststripsandpH-FixPTtubes
Reagent bottles for VISOCOLOR ® alpha,ECO,HEandQUANTOFIX®
Trick lid tubes for pH indicator papers and qualitative test papers
Slid lid tubes forpH-Fix
Accessories manuals,colorscalesand accessories
VISOCOLOR ®Innen Headline 16pt Orange_WeißHinterlegtInnen Fließtext 10ptSchwarz
www.mn-net.com www.mn-net.com
Maximum flexibility - Compact photometer PF-12Adaptedtoourcustomers´requirementsthePF-12impresseswithmoderndesignandpreciseanalytics.Morethan100preprogrammedmethods,automaticwavelenghtadjustmentandtheintuitiveuserguidanceallowfastandeasyoperation.
Experience flexibility•Morethan100preprogrammedVISOCOLOR® ECO andNANOCOLOR® tube tests•Programmablefor20user-definedmethods•Photometricbasicfunctions:absorbance,transmission,factorandstandard
Save time•Operationwithoutcomplexandtime-consumingtraining•Backlitgraphicdisplaywithself-explanatoryuserguidance•Progressivelydesignedopticsisinsensitivetoexternallight
and makes measuring straightforward
Assure results• GLP-conform storage of results•Fastandeasyaccesstostoredresultsanddatasets•ComfortabledataexportwithincludedNANOCOLOR® software DVD
Photometer PF-12 REF 919 200Incl.Software,manual,batteries,emptytesttubes,funnel,beaker,syringe,USBcable,calibrationcuvetteandcertificateinruggedcase
Small, strong, smart – Compact photometer PF-3Thesmallestandyoungestmemberof theMACHEREY-NAGELphotometer family, thenewcompactphotometerPF-3,isideallysuitedformobileusedirectlyatthepointofinterest.AsthePF-3isequippedwith3differentwavelengths,itwillbeavailableinmultipleversionsfordifferentapplications.AlsoforthePF-3MACHEREY-NAGELoffersnumerousreagentcases.
Small and though• Especially handy and light by compact dimensions• Water proof according to IP 68• Shock-resistant optics
Easy and convenient•Fullydevelopedmenustructureusingjust4buttons•Testselectionwithinseconds•Optionalstorageforjustone0-measurement
Smart and clever Add new tests and parameters anytime•PowersupplyanddatatransferviaUSBport•Storageof50measurements
Compact photometer PF-3 (Version A) (Cl2,pH,Cya,TA,CIO2,F–,Fe) REF 934 102Incl.manual,batteries,certificateandaccessoriesinruggedcaseCompact photometer PF-3 (Version E) (NH4-N,K+,NO3-N,PO4-P) REF 934 202Incl.manual,batteries,certificateandaccessoriesruggedcase
More information and a complete list of all versions are available on www.mn-net.com/PF-3 or on request from MACHEREY-NAGEL.
VISOCOLOR ®
www.mn-net.com www.mn-net.com
Program VISOCOLOR®
Ordering information
Test Range (visual)
Type No. of tests
REFTest kit Refill pack
AcidityAC7*(basecapacity) 0.2–7.2mmol/LH+ 1) HE 200 915 006 915 206AlkalinityAL7*(total) 0.2–7.2mmol/LOH– 1) HE 200 915 007 915 207AlkalinityTA3) 0.10–5.00mmol/LH+ ECO 100 – 931 204Alkalinity(p/m-value) seeCarbonatehardnessC20Aluminum 0.10–0.50mg/LAl3+ ECO 50 931 006 931 206Ammonium15* 0.5–15mg/LNH4
+ ECO 50 931 010 931 210Ammonium* 0.2–3mg/LNH4
+ alpha 50 935 012 –Ammonium3* 0.2–3mg/LNH4
+ ECO 50 931 008 931 208Ammonium* 0.02–0.50mg/LNH4
+ HE 110 920 006 920 106Bromine 2) 3) 0.10–13.00mg/LBr2 ECO 200 – 931 211CalciumCA20* 0.6–25.0°e/0.1–3.6mmol/LCa2+ 1) HE 200 915 010 915 210Calcium* 1dropf5mg/LCa2+ ECO 100 931 012 –Carbonate hardness* 1dropf1.25°ef17.8mg/LCaCO3 alpha 100 935 016 –Carbonate hardness* 1dropf1.25°ef17.8mg/LCaCO3 ECO 100 931 014 –CarbonatehardnessC20* (p/m-value)
0.6–25.0°e/0.2–7.2mmol/LH+ 1) HE 200 915 003 915 203
Chloride* 1–60mg/LCl– ECO 90 931 018 931 218ChlorideCL500* 5–500mg/LCl– 1) HE 300 915 004 915 204Chlorine,free 0.25–2.0mg/LCl2 alpha 150 935 019 –Chlorine2*,free+total 0.1–2.0mg/LCl2 ECO 150 931 015 931 215freeChlorine2* 0.1–2.0mg/LCl2 ECO 150 931 016 931 216Chlorine6,free+total2) 3) 0.05–6.00mg/LCl2 ECO 200 – 931 217free Chlorine 6 2) 3) 0.05–6.00mg/LCl2 ECO 400 – 931 219Chlorine* 0.02–0.60mg/LCl2 HE 160 920 015 920 115Chlorine + pH see Swimming poolChlorinedioxide* 0.2–3.8mg/LClO2 ECO 150 931 021 931 221Chromium(VI)* 0.02–0.50mg/LCr(VI) ECO 140 931 020 931 220Copper 0.1–1.5mg/LCu2+ ECO 100 931 037 931 237Copper 0.04–0.50mg/LCu2+ HE 150 920 050 920 150Cyanide* 0.01–0.20mg/LCN– ECO 100 931 022 931 222Cyanide* 0.002–0.04mg/LCN– HE 50 920 028 920 128Cyanuric acid 10–100mg/LCya ECO 100 931 023 931 223DEHA*(diethylhydroxylamine) 0.01–0.30mg/LDEHA ECO 125 931 024 931 224Fluoride2) 3) 0.1–2.0mg/LF– ECO 150 – 931 227total Hardness* 1dropf1.25°ef17.8mg/LCaCO3 alpha 100 935 042 –total Hardness* 1dropf1.25°ef17.8mg/LCaCO3 ECO 110 931 029 –totalHardnessH20F* 0.6–25.0°e/0.1–3.6mmol/LCa2+ 1) HE 200 915 005 915 205totalHardnessH2* 0.06–2.50°e/0.01–0.36mmol/LCa2+ 1) HE 200 915 002 915 202residual Hardness * 0.05–0.37°e alpha 200 935 080 –Hydrazine* 0.05–0.40mg/LN2H4 ECO 130 931 030 931 230Iron1* 0.04–1.0mg/LFe ECO 200 931 025 931 225Iron2 0.04–1.0mg/LFe ECO 100 931 026 931 226Iron 0.01–0.20mg/LFe HE 300 920 040 920 140ThemeasurementrangeofphotometricdeterminationwithphotometerPF-3andPF-12canbedifferent.1)Fortitrationtestkitstherangecanbeincreasedusingadditionaltitrationsolution. 2)onlyforthephotometricdeterminationwithPF-12 3)onlyforthephotometricdeterminationwithPF-3 4)basedonthechemicalproceduresoftheGermanStandardMethods(DEV)*Thisproductcontainsharmfulsubstanceswhichmustbespeciallylabeledashazardous.FordetailedinformationpleaseseeMSDS.
NEW!
NEW!
VISOCOLOR ®
www.mn-net.com www.mn-net.com
Program VISOCOLOR®
Ordering information
Test Range (visual)
Type No. of tests
REFTest kit Refill pack
Manganese* 0.1–1.5mg/LMn ECO 70 931 038 931 238Manganese* 0.03–0.50mg/LMn HE 100 920 055 920 155Nickel* 0.1–1.5mg/LNi2+ ECO 150 931 040 931 240Nitrate* 2–50mg/LNO3
– alpha 100 935 065 –Nitrate* 1–120mg/LNO3
– ECO 110 931 041 931 241Nitrite* 0.05–1.0mg/LNO2
– alpha 200 935 066 –Nitrite* 0.02–0.5mg/LNO2
– ECO 120 931 044 931 244Nitrite* 0.005–0.10mg/LNO2
– HE 150 920 063 920 163pH5–9* pH5.0–9.0 alpha 200 935 075 –pH4.0–9.0* pH4.0–9.0 ECO 400 931 066 931 266pH4.0–10.0* pH4.0–10.0 HE 500 920 074 920 174pH6.0–8.22) 3) pH6.0–8.2 ECO 150 – 931 270Phosphate* 2–20mg/LPO4
3– alpha 70 935 079 –Phosphate* 0.2–5mg/LPO4-P ECO 80 931 084 931 284Phosphate* 0.05–1.0mg/LP HE 300 920 082 920 182Phosphate*(DEV)4) 0.01–0.25mg/LP HE 100 920 080 920 180Potassium* 2–15mg/LK+ ECO 60 931 032 931 232Residualhardness seeHardness(residual)Oxygen* 1–10mg/LO2 ECO 50 931 088 931 288OxygenSA10* 0.2–10mg/LO2 1) HE 100 915 009 915 209Silica*/silicon 0.2–3.0mg/LSiO2 ECO 80 931 033 931 233Silica*/silicon 0.01–0.30mg/LSi HE 120 920 087 920 187Sulfate* 25–200mg/LSO4
2– ECO 100 931 092 931 292Sulfide* 0.1–0.8mg/LS2– ECO 90 931 094 931 294Sulfite* 1dropf1mg/LSO3
2– ECO 60 931 095 –SulfiteSU100* 2–100mg/LSO3
2– 1) HE 100 915 008 915 208Swimming pool* (Chlorine+pH)
0.1–2.0mg/LCl2 pH6.9–8.2
ECO 150 150
931 090 931 290
Zinc* 0.5–3mg/LZn2+ ECO 120 931 098 931 298ThemeasurementrangeofphotometricdeterminationwithphotometerPF-3andPF-12canbedifferent.1)Fortitrationtestkitstherangecanbeincreasedusingadditionaltitrationsolution. 2)onlyforthephotometricdeterminationwithPF-12 3)onlyforthephotometricdeterminationwithPF-3 4)basedonthechemicalproceduresoftheGermanStandardMethods(DEV)*Thisproductcontainsharmfulsubstanceswhichmustbespeciallylabeledashazardous.FordetailedinformationpleaseseeMSDS.
www.mn-net.com
www.mn-net.comMACHEREY-NAGEL GmbH & Co. KG · Neumann-Neander-Str. 6–8 · 52355 Düren · GermanyFrance:MACHEREY-NAGEL EURLTel.: +33 388 68 22 68Fax: +33 388 51 76 88E-mail: [email protected]
Switzerland:MACHEREY-NAGEL AGTel.: +41 62 388 55 00Fax: +41 62 388 55 05E-mail: [email protected]
Germanyand international:Tel.: +49 24 21 969-0Fax: +49 24 21 969-199E-mail: [email protected]
MACHEREY-NAGEL
EN ISO 9001: 2008CERTIFIED
USA:MACHEREY-NAGEL Inc.Tel.: +1 484 821 0984Fax: +1 484 821 1272E-mail: [email protected]
KATE
N100058/VISOCOLO
Ren2/2/0/11.2013PD
Prin
ted
in G
erm
any
Imag
e C
redi
ts: ©
sherez,dicktraven,christian42,JanineFretzWeber,JorgeGonzalez,MichaelFritzen,Maria.P./Fotolia.de
ApplicationsUniversally applicable
Soil analysis Aquaculture Breweries Chemical industry
Electroplating industry Food & beverage industries Leather industry Metal processing industry
Milk industry Pool & spa care Textile industry Cement & concrete production
Customized case solutionsCateringtoourindividualcustomerneedsisoneofthegreatimportancetoMACHEREY-NAGEL.Eventhoughourcasesolutionsprovideahigh levelof flexibility,we recognize that somecustomersmayhavespecific requirementsoutsideourexisting casesolutions.Therefore,weofferentirely individual solutionswitha foam inlaydesignedexactly to your specificationsandtestingneeds.Startingwithaminimumof50cases,wecanprovideyouwithacasethatperfectlyfitsyourpersonalrequirements.Wealsoofferreadilypackedcasesstartingataminimumquantityof50casesaswell. Thus,withinourhighlyflexiblecaserange,wecanprovidevirtuallyanycustomerwiththeperfecttestingandtransportationsolution.
Contact
Technicalsupportandcustomerservice forFiltration,RapidTests,WaterAnalysis: +492421/969161 +492421/969138 +492421/969190 +492421/969174 +492421/969340 +492421/969187 [email protected]
VISOCOLOR ®
Your local distributor: