Upload
lehanh
View
214
Download
0
Embed Size (px)
Citation preview
2
Hig
h P
erfo
rman
ce F
TTA
Site
Sol
utio
ns
Rosenberger @ Asia PacificRosenberger was founded in 1958. It ranks among the leading telecommunication solution providers. To better serve Asian customers, Rosenberger expanded its business in 1997 with the launch of Rosenberger Asia Pacific. From the beginning, Rosenberger Asia Pacific has enjoyed tremendous growth. There are currently 5 factories operating across China with more than 3000 employees and 50,000 M2 of production area, which support 5 product groups:• Communication System Solutions• IT/Data Communication• Testing and Measurement• Automotive• Medical & Industries
A sales network covering the entire Asian-Pacific region generates an annual turnover close to 200 million USD. Reliability and competitiveness are the cornerstones of this sustainable growth, resulting in long term partnerships with most of the leading companies in their respective industries.
Communication System Solutions• Base Station Antenna Feeder Systems
• Wireless Coverage Optimization Solutions
• Microwave Backhaul Solutions
• RF in Cabinet Solutions
• Passive Intermodulation Measurement Systems
• FTTA/FTTH Optical Fiber Solutions
• OSP Fiber Optic Outside Plant Solutions
• In Building Optical Network Connecting Solutions
• Low Frequency Cables and Components
• Network Optimization Services
IT/Data Communication• Premise Network Cabling Products
• Data Center/Cloud Computing Solutions
• Intelligent Infrastructure Management System
Testing and Measurement• Test Cables
• Precision Connectors
• Calibrations
• Accessories and Tools
Automotive• FAKRA Connectors and Cable Assemblies
• HSD® System
Medical & Industries• Non-Magnetic RF Connectors
• Non-Magnetic RF Cable Assemblies
• Data/RF/Power/DC Hybrid Connectors and Assemblies
• Custom Data/Power Connectivity System
• Fiber Optic Connectivity Products
Along with the expansion of product lines, Rosenberger has established new business unit of Rosenberger (Shanghai) Technology Co.,Ltd, which offers unique and innovative wireless communication products and solutions.
Through its long experience in a wide range of technologies, vast R&D investments, and emphasis on customer satisfaction and quality, Rosenberger Asia Pacific is poised to keep its leading role and continue its rapid expansion.
With an unwavering commitment to the core values of customer focus, value innovation, sustainable growth and social responsibility, Rosenberger meets the expectation of its customers as well as its employees.
Product Portfolio
3
High P
erformance FTTA S
ite Solutions
INTRODUCTION ----------------------------------------------------------------------------------------RDC PLUG CABLE ASSEMBLIES ---------------------------------------------------------------RDC SOCKET CABLE ASSEMBLIES ------------------------------------------------------------RQC CABLE ASSEMBLIES --------------------------------------------------------------------------RQC SOCKET CABLE ASSEMBLy ----------------------------------------------------------------FTTA CABLE ASSEMBLIES BASED ON STANDARD FIBER CONNECTORS -------REC CABLE ASSEMBLIES --------------------------------------------------------------------------RMC CABLE ASSEMBLIES --------------------------------------------------------------------------RNGC CABLE ASSEMBLIES ------------------------------------------------------------------------FTTA FIBER TRUNK -----------------------------------------------------------------------------------FTTA FIBER TRUNK WITH RDC BREAKOUT -------------------------------------------------MULTI-FIBER TRUNK WITH RUGGEDIZED BREAKOUT ----------------------------------FTTA HyBRID TRUNK --------------------------------------------------------------------------------FTTA FIBER DISTRIBUTION UNIT ----------------------------------------------------------------FTTA FIBER CABLE STORAGE BOX -------------------------------------------------------------FIBER / POWER CABLE CLAMP ------------------------------------------------------------------ROSENBERGER SERVICE--------------------------------------------------------------------------
4579
11131517192123252729313335
CONTENT
4
Hig
h P
erfo
rman
ce F
TTA
Site
Sol
utio
ns
INTRODUCTION
Fiber-to-the Antenna (FTTA) Site Solutions from Rosenberger – secure your network connectivity today
and in the future
There is a huge demand for high-speed data transfers in today’s global mobile
telecommunication networks. The connectivity performance between the
base station and RRU / Antenna is the key to the quality of the data transfer
between the network and the end-user. Our extensive experience with fiber optic
technology, innovative product development and our long-term relationships with
the largest service providers and OEMs in the telecommunication industry enable
us to develop forward reaching and universally applicable FTTA cabling systems
that will be technology leaders for many generations.
Standard application and norm standard
• Connectors compatible with all international standards and norm specifications
• Cabling solutions quickly to be adjusted to new equipment systems
• Cost-efficient and economic system
Outstanding product features
• High UV resistance of the cable sheaths
• Waterproof installation tube in compliance with IP 67
• Grip for hoisting the pre-fabricated cable
• Extremely robust products
Fast and safe installation
Rosenberger cabling system:
• Pre-fabricated with up to 24 coded fibers*
• Immediate installation possible
• Fiber jumpers and trunks individually tested and supplied with measurement
details
• Robust and safe packaging
Benefits of Rosenberger structured FTTA cabling systems
• Employs well-known proven fiber optic technology
• Innovative interconnect technology that can be adapted to upgrades in active
equipment
• A partner independent of the original equipment suppliers
• Sturdy / robust multi-fiber cable
• Pair coded cable which assures easy and error-free installation
• Connector interfaces conform to international standards at all interconnections * higher fiber counts on request
5
High P
erformance FTTA S
ite Solutions
RDC PLUG CABLE ASSEMBLIES
Description
Specifications
Optical Data Mechanical Data
Environmental Data
* Other cable size options are available upon request.
Such fiber optical cable assemblies connect remote radio heads/units
(RRH/RRU) with base stations in mobile communication applications.
They can be used indoor and outdoor, are UV protected. The Rosenberger
Duplex Connector (RDC) is intermateable with ODC®-2.
• 2 fibers, singlemode or multimode
• ruggedized RDC for RRH/RRU connection
• easy and quick manual installation
• Pulling sock available
RDC Connector
Insertion Loss Max. 0.5dB
Return Loss Min. 50dB single-mode
LC / SC Connector
Insertion Loss Max. 0.3dB
Return Loss Min. 50dB single-mode
Cable Diameter 4.8mm*
Cable Minimum Bending Radius
Installation 75mm
Operation 50mm
Cable Maximum Tensile Strength
Installation 450N
Operation 300N
Cable Crush Resistance 1KN/100mm
Temperature Range Operation -40℃ - +85℃
Temperature Range Storage -40℃ - +70℃
Temperature Range Installation -10℃ - +65℃
2002/95/EC (RoHS) Compliant
Ingress Protection (Mated) IP67
Reference Drawing
6
Hig
h P
erfo
rman
ce F
TTA
Site
Sol
utio
ns
Part Number Scheme
Ordering Example
L98
Length
5000 5meters
10000 10meters
30000 30meters
50000 50meters
100000 100meters
150000 150meters
200000 200meters
Fiber Type
A SM, G652D
B SM,G657
C MM, 50/125
D MM, 50/125, OM3
F MM, 62.5/125
Connectors, Breakout Length (A)
800 RDC (m) - LCD, A = 255mm
801 RDC (m) - SCD, A = 255mm
L98A-800-10000RDC (m)-LCD Cable Assembly, SM, G652D, Length 10M
6
Hig
h P
erfo
rman
ce F
TTA
Site
Sol
utio
ns
7
High P
erformance FTTA S
ite Solutions
RDC SOCKET CABLE ASSEMBLIESDescription
Specifications
Optical Data Mechanical Data
Environmental Data
* For G.652D fiber.
RDC socket cable assembly is applicable for inside-cabinet installation with
RDC socket anchored and accessible for RDC plug mating from outside
cabinet. One of typical applications of mobile communication is to pre-load such
cable assembly into remote radio head/unit (RRH/RRU).The RDC socket is
intermateable with ODC®-2.
• Indoor duplex cable, singlemode or multimode
• RDC socket with square or hexagonal flange
• Dust cap available
RDC socket
Insertion Loss Max. 0.5dB
Return Loss (Singlemode) Min. 50dB single-mode
LC Duplex Connector
Insertion Loss Max. 0.3dB
Return Loss (Singlemode) Min. 50dB single-mode
Cable Diameter 2mm (zipcord)
Cable Minimum Bending Radius
Installation 45mm*
Operation 30mm*
Cable Maximum Tensile Strength
Installation 100N
Operation 60N
Cable Crush Resistance 100N/100mm
Temperature Range Operation -40℃ - +85℃
Temperature Range Storage -40℃ - +70℃
Temperature Range Installation -10℃ - +65℃
2002/95/EC (RoHS) Compliant
Reference Drawing
8
Hig
h P
erfo
rman
ce F
TTA
Site
Sol
utio
ns
Part Number Guide
Ordering Example
L98
Length
500 0.5meters
1000 1.0meters
Fiber Type
A SM, G652D
B SM,G657
C MM, 50/125
D MM, 50/125, OM3
F MM, 62.5/125
Connectors, Breakout Length (A)
802 RDC Socket LCD
803 RDC Socket SCD
L98A-803-500RDC Socket-SCD Cable Assembly, SM, G652D, Length 0.5M
8
Hig
h P
erfo
rman
ce F
TTA
Site
Sol
utio
ns
9
High P
erformance FTTA S
ite Solutions
RQC CABLE ASSEMBLIES
Description
Specifications
Optical Data Mechanical Data
Environmental Data* Other cable size options are available upon request
Such fiber optical cable assemblies connect remote radio heads/units (RRH/
RRU) with base stations in mobile communication applications.They can be used
indoor and outdoor, are UV protected. The Rosenberger Quad Connector (RQC)
is intermateable with ODC®-4.
• 4 fiber, singlemode or multimode
• Ruggedize RQC for RRH/RRU connection
• Easy and quick manual installation
• Pulling sock available
RQC Connector
Insertion Loss Max. 0.5dB
Return Loss Min. 50dB
LC/SC Connector
Insertion Loss Max. 0.3dB
Return Loss Min. 50dB single-mode
Cable Diameter 5mm*
Cable Minimum Bending Radius
Installation 75mm
Operation 50mm
Cable Maximum Tensile Strength
Installation 450N
Operation 300N
Cable Crush Resistance 1KN/100mm
Temperature Range Operation -40℃ - +85℃
Temperature Range Storage -40℃ - +70℃
Temperature Range Installation -10℃ - +65℃
2002/95/EC (RoHS) Compliant
Ingress Protection IP 67
Reference Drawing
10
Hig
h P
erfo
rman
ce F
TTA
Site
Sol
utio
ns
Part Number Scheme
Ordering Example
L98
Length
5000 5meters
10000 10meters
30000 30meters
50000 50meters
100000 100meters
150000 150meters
200000 200meters
Fiber Type
A SM, G652D
B SM, G657
C MM, 50/125
D MM, 50/125, OM3
F MM, 62.5/125
Connectors, Breakout Length (A)
831 RQC (m) - LCD, A = 255mm
832 RQC (m) - SCD, A = 255mm
L98A-831-10000RDC (m)-LC Cable Assembly, SM, G652D, Length 10M
10
Hig
h P
erfo
rman
ce F
TTA
Site
Sol
utio
ns
11
High P
erformance FTTA S
ite Solutions
RQC SOCKET CABLE ASSEMBLy
Description
Specifications
Optical Data Mechanical Data
Environmental Data*Other cable size options are available upon request
RQC socket cable assembly is applicable for inside-cabinet installation with RQC
socket anchored and accessible for RQC plug mating from outsidecabinet. One of
typical applications of mobile communication is to pre-load such cable assembly
into remote radio head/unit (RRH/RRU).The RQC socket is intermateable with
ODC®-4.
• Indoor 4C Cable, single-mode or multimode
• RDC socket with square or multimode
• Dust cap available
RQC Connector
Insertion Loss Max. 0.5dB
Return Loss Min. 50dB
LC/SC Connector
Insertion Loss Max. 0.3dB
Return Loss Min. 50dB single-mode
Cable Diameter 1.8mm*4
Cable Minimum Bending Radius
Installation 45mm*
Operation 30mm*
Cable Maximum Tensile Strength
Installation 100N
Operation 60N
Cable Crush Resistance 100N/100mm
Temperature Range Operation -40℃ - +85℃
Temperature Range Storage -40℃ - +70℃
Temperature Range Installation -10℃ - +65℃
2002/95/EC (RoHS) Compliant
Ingress Protection IP 67
Reference Drawing
12
Hig
h P
erfo
rman
ce F
TTA
Site
Sol
utio
ns
12
High P
erformance FTTA S
ite Solutions
Part Number Guide
Ordering Example
L98
Length
500 0.5meters
1000 1.0meters
Fiber Type
A SM, G652D
B SM, G657
C MM, 50/125
D MM, 50/125, OM3
F MM, 62.5/125
Connectors, Breakout Length (A)
833 RQC Socket LCD
834 RQC Socket SCD
L98A-834-500RQC Socket-SCD Cable Assembly, SM, G652D, Length 0.5M
12
Hig
h P
erfo
rman
ce F
TTA
Site
Sol
utio
ns
13
High P
erformance FTTA S
ite Solutions
FTTA CABLE ASSEMBLIESBASED ON STANDARD FIBER CONNECTORS
Description
Specifications
Optical Data Mechanical Data
Environmental Data
* Other cable size options are available upon request.
Such fiber optical cable assemblies use conventional standard connector to
connect remote radio heads/units (RRH/RRU) with base stations in mobile
communication applications. They can be used indoor and outdoor, are UV
protected.
Connector
Insertion Loss Max. 0.3dB
Return Loss Min. 50dB single-mode
Cable diameter: 4.8mm*
Cable Minimum Bending Radius
Installation 75mm
Operation 50mm
Cable Maximum Tensile Strength
Installation 450N
Operation 300N
Cable Crush Resistance 1KN/100mm
Temperature Range Operation -40℃ - +85℃
Temperature Range Storage -40℃ - +70℃
Temperature Range Installation -10℃ - +65℃
2002/95/EC (RoHS) Compliant
Reference Drawing
14
Hig
h P
erfo
rman
ce F
TTA
Site
Sol
utio
ns
Part Number Guide
Ordering Example
L98
Fiber Type
A SM, G652D
B SM,G657
C MM, 50/125
D MM, 50/125, OM3
F MM, 62.5/125
Connectors, Breakout Length (A)
804 LCD - LCD
805 SCD - SCD
L98C-804-50000LCD-LCD Cable Assembly, MM, 50/125um, Length 50M
Length
5000 5meters
10000 10meters
30000 30meters
50000 50meters
100000 100meters
150000 150meters
200000 200meters
14
Hig
h P
erfo
rman
ce F
TTA
Site
Sol
utio
ns
15
High P
erformance FTTA S
ite Solutions
REC CABLE ASSEMBLIES
Description
Specifications
Optical Data Mechanical Data
Environmental Data* Other cable size options are available upon request.
Such fiber optical cable assemblies connect remote radio heads/units (RRH/
RRU) with base stations in mobile communication applications. They can be
used indoor and outdoor, are UV protected. The Rosenberger Efficient Connector
(REC) utilizes standard LC connector with extra protection to work under harsh
environment.
REC Connector
Insertion Loss Max. 0.3dB
Return Loss Min. 50dB single-mode
LC/SC Duplex Connector
Insertion Loss Max. 0.3dB
Return Loss Min. 50dB single-mode
Cable diameter: 4.8mm*
Cable Minimum Bending Radius
Installation 75mm
Operation 50mm
Cable Maximum Tensile Strength
Installation 450N
Operation 300N
Cable Crush Resistance 1KN/100mm
Temperature Range Operation -40℃ - +85℃
Temperature Range Storage -40℃ - +70℃
Temperature Range Installation -10℃ - +65℃
2002/95/EC (RoHS) Compliant
Ingress Protection (Mated) IP67
Reference Drawing
16
Hig
h P
erfo
rman
ce F
TTA
Site
Sol
utio
ns
Connectors, (Side A - Side B)
810 REC - LCD
811 REC - SCD
Part Number Guide
Ordering Example
L98
Length
5000 5meters
10000 10meters
30000 30meters
50000 50meters
100000 100meters
150000 150meters
200000 200meters
Fiber Type
A SM, G652D
B SM,G657
C MM, 50/125
D MM, 50/125, OM3
F MM, 62.5/125
L98A-810-50000REC – LCD Cable Assembly, SM, G652D, Length 50M
16
Hig
h P
erfo
rman
ce F
TTA
Site
Sol
utio
ns
17
High P
erformance FTTA S
ite Solutions
RMC CABLE ASSEMBLIES
Description
Specifications
Optical Data Mechanical Data
Environmental Data
RMC Connector
Insertion Loss Max. 0.7dB single-mode 0.6dB multi-mode
Return Loss Min. 55dB single-mode (Angle Polish)
LC/SC Duplex Connector
Insertion Loss Max. 0.3dB
Return Loss Min. 50dB single-mode
Cable diameter: 5~8mm
Cable Minimum Bending Radius
Installation 75mm
Operation 50mm
Cable Maximum Tensile Strength
Installation 450N
Operation 300N
Cable Crush Resistance 1KN/100mm
Temperature Range Operation -40℃ - +85℃
Temperature Range Storage -40℃ - +70℃
Temperature Range Installation -10℃ - +65℃
2002/95/EC (RoHS) Compliant
Ingress Protection (Mated) IP67
Such fiber optical cable assemblies connect remote radio heads/units
(RRH/RRU) with base stations in mobile communication applications.
They can be used indoor and outdoor, are UV protected. The
Rosenberger Multi-fiber Connector (RMC) utilizes standard MPO fiber
interface with extra protection to work under harsh environment.
• 4~12 fibers, singlemode or multimode
• Standard MPO interface
• Easy manual installation
• Pulling sock available
Reference Drawing
18
Hig
h P
erfo
rman
ce F
TTA
Site
Sol
utio
ns
Part Number Guide
Ordering Example
L98
Length
5000 5meters
10000 10meters
30000 30meters
50000 50meters
100000 100meters
150000 150meters
200000 200meters
Fiber Type
A SM, G652D
B SM,G657
C MM, 50/125
D MM, 50/125, OM3
F MM, 62.5/125
Connectors, (Side A - Side B)
806 RMC - LCD x 2, 4 - Fibre
807 RMC - SCD x 2, 4 - Fibre
808 RMC - LCD x 3, 6 - Fibre
809 RMC - SCD x 3, 6 - Fibre
L98A-806-10000RMC – LCDX2 Cable Assembly, 4-Fiber, SM, G652D, Length 10M
18
Hig
h P
erfo
rman
ce F
TTA
Site
Sol
utio
ns
19
High P
erformance FTTA S
ite Solutions
RNGC CABLE ASSEMBLIES
Description
Specifications
Optical Data Mechanical Data
Environmental Data
* Other cable size options are available upon request.
Insertion Loss Max. 0.3dB
Return Loss Min. 50dB single-mode
Cable diameter: 5~8mm
Cable Minimum Bending Radius
Installation 75mm
Operation 50mm
Cable Maximum Tensile Strength
Installation 450N
Operation 300N
Cable Crush Resistance 1KN/100mm
Temperature Range Operation -40℃ - +85℃
Temperature Range Storage -40℃ - +70℃
Temperature Range Installation -10℃ - +65℃
2002/95/EC (RoHS) Compliant
Ingress Protection (Mated) IP67
RNGC cable assemblies connect remote radio heads/units (RRH/RRU)
with radio base stations in mobile communication applications. They
can be used indoor and outdoor, and are UV protected. Rosenberger
Next Generation Connector (RNGC) utilizes standard LC duplex
interface with extra protection to work under harsh environment.
RNGC connector is specifically suitable for directly connecting with
exchangeable SFP module.
• 2 fibers, singlemode or multimode
• Standard LC duplex interface
• Supporting connection with SFP module
• Easy manual installation
• Pulling sock available
Reference Drawing
20
Hig
h P
erfo
rman
ce F
TTA
Site
Sol
utio
ns
Part Number Guide
Ordering Example
L98
Length
5000 5meters
10000 10meters
30000 30meters
50000 50meters
100000 100meters
150000 150meters
200000 200meters
Fiber Type
A SM, G652D
B SM,G657
C MM, 50/125
D MM, 50/125, OM3
F MM, 62.5/125
Connectors, (Side A - Side B)
812 RNGC - LCD x 2, 4 - Fibre
813 RNGC - SCD x 2, 4 - Fibre
L98A-812-10000RNGC – LCD Cable Assembly, SM, G652D, Length 10M
20
Hig
h P
erfo
rman
ce F
TTA
Site
Sol
utio
ns
21
High P
erformance FTTA S
ite Solutions
FTTA FIBER TRUNK
Description
Specifications
Optical Data for Connectors Mechanical Data
Environmental Data
Insertion Loss Max. 0.3dB
Return Loss Min. 50dB single-mode
Cable Diameter
6 and 12 Fibers 8mm
18 and 24 Fibers 10mm
Cable Minimum Bending Radius
Installation 150mm
Operation 100mm
Cable Maximum Tensile Strength
Installation 2500N
Operation 600N
Cable Crush Resistance 1KN/100mm
Temperature Range Operation -40℃ - +80℃
Temperature Range Storage -40℃ - +80℃
Temperature Range Installation -10℃ - +65℃
2002/95/EC (RoHS) Compliant
FTTA fiber trunks are fiber optical cable assemblies connecting base stations and
remote radio heads in telecommunication applications. They can be used indoor
and outdoor, are UV protected.
Connectors and fan-out are IP67 protected. This ensures easy handling in an
outdoor environment.
• 6~24 fibers, singlemode or multimode
• Standard fiber interface
• Guaranteed performance based on 100% quality inspection in factory
• Easy and quick installation
• Pulling sock available
Reference Drawing
22
Hig
h P
erfo
rman
ce F
TTA
Site
Sol
utio
ns
Part Number Scheme
Ordering Example
L98
Length
5000 5meters
10000 10meters
30000 30meters
50000 50meters
100000 100meters
150000 150meters
200000 200meters
Fiber Type
A SM, G652D
B SM, G657
C MM, 50/125
D MM, 50/125, OM3
F MM, 62.5/125
Connectors, (Side A - Side B)
814 LCD - LCD , 6 - Fibre
815 LCD - LCD 12 - Fibre
816 LCD - LCD 24 - Fibre
817 SCD - SCD , 6 - Fibre
818 SCD - SCD 12 - Fibre
819 SCD - SCD 24 - Fibre
L98C-817-10000FTTA 6-Fiber Trunk, SCD-SCD, MM, 50/125, Length 10M
22
Hig
h P
erfo
rman
ce F
TTA
Site
Sol
utio
ns
23
High P
erformance FTTA S
ite Solutions
FTTA FIBER TRUNK WITH RDC BREAKOUTDescription
Specifications
Optical Data Mechanical Data
Environmental Data
Cable
Fiber 9/125u Single mode fiber, G657A2
Fiber Count 8F
Cable Attenuation ≤0.45 dB/km@1310nm≤0.30 dB/km@1550nm
Assembly
Insertion Los
Max: ≤ 0.5dB +0.45 dB/km*L @1310nm≤ 0.5dB +0.30 dB/km*L @1550nmAccording to IEC 61300-3-4 method B
Return Loss MIN: 50 dB According to IEC 61300-3-6
Cable Diameter
6 and 12 Fibers 6.5mm
18 and 24 Fibers 3.0mm
Cable Minimum Bending Radius
Installation 10xD
Operation 20xD
Cable Maximum Tensile Strength
Long Term 200N
Short Term 600N
Crush Resistance 1000N/100mm (short term)
Minimum Bending Radius Single Fan-out
Single 30mm
Repeated 30mm
Temperature Range Operation -40℃ - +70℃
Temperature Range Storage -40℃ - +70℃
Temperature Range Installation -10℃ - +65℃
2002/95/EC (RoHS) Compliant
FTTA fiber trunks are fiber optical cable assemblies connecting base stations and
remote radio heads in telecommunication applications. They can be used indoor
and outdoor and are UV protected.
Connectors and fan-out are IP67 protected. This ensures easy handling in an
outdoor environment. A pulling sock eases cable hoisting.
RDC metal cover is aslo available.
Reference Drawing
24
Hig
h P
erfo
rman
ce F
TTA
Site
Sol
utio
ns
Part Number Scheme
Ordering Example
L98
Length
5000 5meters
10000 10meters
30000 30meters
50000 50meters
100000 100meters
150000 150meters
200000 200meters
Fiber Type
A SM, G652D
B SM, G657
C MM, 50/125
D MM, 50/125, OM3
F MM, 62.5/125
Connectors, Breakout Length (A)
578 FTTA Trunk 4RDC-4RDC
L98A-578-10000FTTA Trunk 4-RDC-9uG657-RDC Length 10M
24
Hig
h P
erfo
rman
ce F
TTA
Site
Sol
utio
ns
25
High P
erformance FTTA S
ite Solutions
MULTI-FIBER TRUNK WITH RUGGEDIZED BREAKOUTDescription
Specifications
Optical Data for Connectors Mechanical Data
Environmental Data
Insertion Loss Max. 0.3dB
Return Loss Min. 50dB single-mode
Cable Diameter
Main Cable (for 6fiber type) 7mm
Breakout Cables 4.8mm
Cable Minimum Bending Radius
Installation 150mm
Operation 100mm
Cable Maximum Tensile Strength
Installation 600N
Operation 450N
Cable Crush Resistance 1KN/100mm
Temperature Range Operation -40℃ - +80℃
Temperature Range Storage -40℃ - +80℃
Temperature Range Installation -10℃ - +65℃
2002/95/EC (RoHS) Compliant
This product applies to FTTA applications. Such cable
assembly use standard connectors on both sides. The featured
ruggedized branching technology support cost effective solution
to connect base station main unit to multiple remote radio units
on same tower of cellular network.
Reference Drawing
26
Hig
h P
erfo
rman
ce F
TTA
Site
Sol
utio
ns
Part Number Scheme
Ordering Example
L98
Length
5000 5meters
10000 10meters
30000 30meters
50000 50meters
100000 100meters
150000 150meters
200000 200meters
Fiber Type
A SM, G652D
B SM,G657
C MM, 50/125
D MM, 50/125, OM3
F MM, 62.5/125
Connectors, (Side A - Side B)
820 LCD - LCD , 6 - Fibre
821 LCD - LCD 12 - Fibre
822 SCD - SCD , 6 - Fibre
823 SCD - SCD , 12 - Fibre
L98A-821-10000FTTA 12-Fiber Trunk with Ruggedized Breakout, LCD-LCD, SM, G652D, Length 10M
26
Hig
h P
erfo
rman
ce F
TTA
Site
Sol
utio
ns
27
High P
erformance FTTA S
ite Solutions
FTTA HyBRID TRUNK
Description
Specifications
Optical Data Mechanical Data
Electrical data at 20°C
Cable
Fiber G657A2 fiber
Cable Attenuation ≤0.7 dB/km@1310nm≤0.7 dB/km@1550nm
Assembly
Insertion Los
Max: ≤ 0.6 dB +0.7 dB /km*L @1310nm≤ 0.6 dB +0.7 dB /km*L @1550nmAccording to IEC 61300-3-4 method B
Return Loss ≥ 50 dB (UPC)According to IEC 61300-3-6
Minimum Bending Radius Cable
Installation 15xcable diameter
Operation 15xcable diameter
Minimum Bending Radius Single Fan-out
Single 30mm
Repeated 30mm
Driver dimension Φ60mm
Height 180mm
Cable Retention Force at Driver
Fiber Break-out Cable 200N
Power Break-out Cable 500N
Hybrid Cable 1000N
Core 4x(2x10mm²)
Conductor Resistance(Single Wire) 1.83Ω/km (max.)
Nominal Voltage Uo/U 600/1000
FTTA hybrid trunks include fiber and copper cables. They are used for data
transmission and power supply between base stations and remote radio heads
in telecommunication applications. The cable jacket material is sunlight resistant
and flame retardand, recommended use is indoor and outdoor. This Cable is
recommend to be used without the hybrid box to reach the IP67 level.
RDC metal cover is aslo available.
Reference Drawing
28
Hig
h P
erfo
rman
ce F
TTA
Site
Sol
utio
ns
Part Number Scheme
Ordering Example
L98
Length
5000 5meters
10000 10meters
30000 30meters
50000 50meters
100000 100meters
150000 150meters
200000 200meters
Fiber Type
A SM, G652D
B SM, G657
C MM, 50/125
D MM, 50/125, OM3
F MM, 62.5/125
Connectors, Breakout Length (A)
538 Power Connector+5RDC-5RDC
L98A-538-10000FTTA Hybrid Trunk
4-x(2x10mm2)+5RDC-9uG657-RDC Length 10M
28
Hig
h P
erfo
rman
ce F
TTA
Site
Sol
utio
ns
29
High P
erformance FTTA S
ite Solutions
FTTA FIBER DISTRIBUTION UNIT
Description
SpecificationsEnvironmental Data
Capacity 6 ports, 12-ports Up to 24-ports
Adapter Type LC duplex adapter
Material Box body Steel, powder coated
Dimensions (mm) 250H x 200W x 60D
Cable Entry
For Trunk Cable 1 x M25 cable gland (pre-loaded)
For RRH/RRU Cable 2 x M20 cable gland (pre-loaded)
TemperatureRange Operation -40℃ - +85℃
Protection Level IP65
2002/95/EC (RoHS) Compliant
This fiber distribution unit is used for fiber management on top
of the mast or at the base station. Brackets ensure an easy
installation at a wall or mast (mast mounting requires additional
mounting material). It features a standard double bit lock and a
corresponding key.
• Compact design with excellent cable management
• Wall-mount or post mount
• IP65 protection level
• Lockable hinged door with key
Reference Drawing
30
Hig
h P
erfo
rman
ce F
TTA
Site
Sol
utio
ns
Part Number Scheme
Ordering Example
FDU
Capacity
006 6 ports
012 6 ports
024 6 ports
Adapter Type
001 LC Duplex Singlemode
002 LC Duplex Multimode
FDU-001-006FTTA Fiber Distribution Unit, 3 x LC Duplex Adapters, Singlemode
30
Hig
h P
erfo
rman
ce F
TTA
Site
Sol
utio
ns
31
High P
erformance FTTA S
ite Solutions
FTTA FIBER CABLESTORAGE BOXDescription
Specifications
Environmental DataCapacity 30meters*
Material Box Body Steel, powder coated
Dimensions (mm) 520H x 520W x 128D
Cable Entries 4pcs, for cables up to 15mm diameter
Temperature Range Operation -40℃ - +85℃
2002/95/EC (RoHS) Compliant
This slack cable storage box is used to accommodate excessive
fiber optical cables at base station side. Fiber cables will be
protected against accidental physical ingress, additionally,
bending radius is properly maintained.
• Indoor/Outdoor use
• Dust-proof
• Wall-mounting
Reference Drawing
32
Hig
h P
erfo
rman
ce F
TTA
Site
Sol
utio
ns
Part Number Scheme
FCS-001-001FTTA Fiber Cable Storage Box, Capacity 30meters
32
Hig
h P
erfo
rman
ce F
TTA
Site
Sol
utio
ns
33
High P
erformance FTTA S
ite Solutions
FIBER / POWER CABLE CLAMP
Description
Specifications
Environmental DataCapacity 3 power cables + 3 fiber cables
Material - Wire Brackets PP
Material - Inserts Silicon
Material - Metal Parts Stainless steel
Suitable Cables
Fiber Cable OD: 4.5-6.5mm
Power Cable OD: 9-13mm
Temperature Range Operation -40℃ - +85℃
Temperature Range Storage -40℃ - +70℃
Temperature Range Installation -10℃ - +65℃
Wind load in std. Installation 200km/h
2002/95/EC (RoHS) Compliant
Such cable clamp is used to fix multiple fiber cables and power cables onto towers where space is limited. Without additional adapters,
these clamps can provide sturdy, reliable, long-term support by means of using tough and UV resistant material.
Reference Drawing
34
Hig
h P
erfo
rman
ce F
TTA
Site
Sol
utio
ns
Part Number Scheme
SLCC221-ZF1Hybrid Cable Clamp for 1 × Power & 1 × Fibre
SLCC241-ZF1Hybrid Cable Clamp for 2 × Power & 2 × Fibre
SLCC261-ZF1Hybrid Cable Clamp for 3 × Power & 3 × Fibre
34
Hig
h P
erfo
rman
ce F
TTA
Site
Sol
utio
ns
35
High P
erformance FTTA S
ite Solutions
RosenbeRgeR seRVICeRosenberger offers professional services that improve network design, reliability, scalability and efficiency.
Our service core competences include:• Network optimization• Technical consultation• Customized product design• Installation & commissioning• Onsite training & supervision• System troubleshooting• After-sales services
In addition, we also offer professional training, technical support and workshops for distributors and agents. We are committed to offering our services in anyway, anywhere and at anytime.
Rosenberger is much more than just a supplier – Rosenberger is a valued development partner and we will strive to devote all effort to meet new challenges in order to scale to new heights.
Rosenberger Asia Pacific Electronic Co., Ltd.No.3, Anxiang Street, Block B, Tianzhu Airport Industrial ZoneBeijing, China 101300Tel : (+86 10) 80481995Fax : (+86 10) 80497052Email: [email protected]
Rosenberger (Shanghai) Technology Co.,LtdNo. 303, Xinke Road, Qingpu Industrial ZoneShanghai, China 201707Tel : (+86 21) 69214567Fax : (+86 21) 69212923
Rosenberger Asia Pacific Electronic Co., Ltd. Shanghai DivisionB7, No. 509, Renqing Road, East Zone of Zhangjiang High-Tech ParkShanghai, China 201201Tel : (+86 21) 58995997Fax : (+86 21) 58995594 Rosenberger Asia Pacific Electronic Co., Ltd. Dongguan Division3rd Floor, Building E, Pingqian Industrial Park, Dongkeng TownDongguan, Guangdong Province, ChinaTel : (+86 769) 82802098Fax : (+86 769) 82802099
Rosenberger All rights reserved. 2nd Edition, 2012 Please visit our website: www.RosenbergerAP.com