L-1519
● Actual plasticizing capacity may vary, depending on the molding conditions and materials used. ● The specifications are subject to change without notice due to performance upgrades. ● 1MPa=10.2kgf/cm2≒10kgf/cm2, 1kN=0.102tf≒0.1tf
"X-Pump" Equipped Ultra-Large Hybrid Injection Molding Machine
NUX2500MODEL
4.92(125)535.4(8774)(294.0)
930.3(422)28580(201)(2010)64.4(1055)3.39(86)0~10023.8(90)
5.51(140)671.6(11006)(368.8)
1360.3(617)22750(160)(1600)80.7(1323)3.39(86)0~10023.8(90)
5.90(150) 771.0(12635)(423.4)
1673.3(759)19910(140)(1400)92.7(1519)3.39(86)0~10023.8(90)
6.30(160)877.2(14376)(481.7)
1940.1(880)17490(123)(1230)105.6(1731)3.39(86)0~10023.8(90)
1100L
2755 (24500) (2500)70.9~102.4(1800~2600)31.5~63.0(800~1600)
133.9(3400)Stationary:30865 (14t) Movable : 46297 (21t)
72.0 × 64.2 (1830×1630)96.9 ×89.0 (2460×2260)
13.7 (348)55kW× 5 + 11kW
113.45555.1×184.7×146.3 (14.1×4.69×3.72)
-279987 (127)541.6 (2050)
Injection
Clamping
Others
Specification item
Screw diameter
Injection capacity
Plasticization capacity (PS)
Max. injection pressure
Injection rate
Injection velocity
Screw speeds
Hopper capacity (Optional)
Clamping force
Clamping stroke
Mold thickness
Max. daylight opening
Max. mold weight
Tie bar clearance (H×V)
Die plate dimensions (H×V)
Ejector stroke
Pump motor
Heater band capacity
Machine dimensions(L×W×H)
Floor dimensions (L×W)
Machine weight
Hydraulic oil quantity
Unit
inch (mm)
inch³ (cm³) (oz)
lbs/h (kg/h)
psi (Mpa) (kgf/cm²)
inch³/s (cm³/s)
inch/s (mm/s)
rpm
Gal (L)
US ton (kN) (tf)
inch (mm)
inch (mm)
inch (mm)
lbs (t)
inch (mm)
inch (mm)
inch (mm)
kW
kW
inch (m)
inch (m)
lbs (t)
Gal (L)
Standard equipment
Performance specifications
Locating ring assembly (fixed type:5")Mold protection (low-pressure clamping time monitor)4-speed mold closing velocity: three-stage high-velocity mold closing and low-velocity/low-pressure mold closing4-speed mold opening velocity: initial mold opening, two-stage high-speed mold opening, and final mold opening Mold clamping pauseClamping compression molding High-pressure clamping force setting unit: psiMulti-functional ejector (ejection start timer, pause, 2-speed forward velocity, halfway change of forward velocity, and variable forward/backward stroke)Ejector plate return confirmation (for circuit only)Mold inside process: MIP0 (sequential operation)Ejection during mold open (simultaneous motion)Clamping pressure full closed controlCapture of mold position setting
Injection process control: 6-speed, 3-pressure, and 3-limit pressureV-P changeover: 4 modes 3-speed heat retention response changeover (fast / middle / slow)Over packing prevention circuitDecompression / decompression before meteringInjection pressure full-closed controlBack pressure and metering velocity: 3-stageInjection start timer / metering start timer / nozzle backward timerInjection position setting unit: inch or mmInjection velocity setting unit: inch/s or mm/sInjection pressure and back pressure setting unit: psi or MPaMetering velocity setting unit: rpmTemperature setting unit: FahrenheitAutomatic purge circuit (3 modes: full stroke, number, and flexible)Purging cover (with interlock)Screw cold start prevention (all-zone sequential type)Nozzle and barrel temperature upper / lower limit alarmNozzle and barrel temperature PID controlNozzle and barrel simultaneous heating
123
4
5678
910111213
12345678910111213141516171819
Nozzle heater circuit SSRBarrel heat retention circuit (forced and emergency retention)
TACT IV (15-inch LCD, dual window display, and sheet switch type operation panel)Shot counter / free shot counterProduction management counter / production lot management counter /cause-classified defective counterMonitor data displayStatistical processing function / scatter diagram display / waveform analysisProduct pass/fail judgment function / batch entry of acceptance level conditionsMolding condition internal memory (up to 500 conditions) Image file management of molding conditionsProduct take-out robot interface: SPI with connectorCalendar timer (hydraulic oil and barrel heating)Built-in LAN port (10 / 100BASE-TX) and USB port (x1)Connection to PC / Saving data to an external USB memoryUSB memoryDisplay of injection velocity and pressure waveformsOperation history display (max. 100,000 events)Molding support messageMultilingual display capability (English, Japanese, Chinese, Spanish, Korean, and Thai)Hour meter / clock function / calculatorLadder programming function and I / O function assignmentSignal recorderAlarm (notification) functionError display functionEmergency power shut off (with delay timer)Cycle alarmRemote maintenance functionSelection of production complete stateChangeable setting unitDescriptions of adjusters (displays the descriptions and important notes for some of the adjusters by touch)Setup mode (mold open / close & ejection by setup speed and injection & metering by purging speed)
Cooling water manifold: 6 channels on stationary side and 6 channels on movable sideHydraulic oil heat-up
Oil temperature stabilizerHydraulic oil upper / lower limit alarmLow oil level alarmHydraulic oil purifier
Alarm lamp (Patlite) / bellEmergency stop button (operator side / non-operator side)Mold clamping safety device (mechanical, electrical, and hydraulic types)/ clamping daylight lower part safety footboardInverter type automatic open/close safety door with a touch switch
Automatic centralized greasing unit (for clamp area except movable platen)Manual centralized greasing unit (for movable platen)Automatic centralized lubricating unit (for injection unit)
ANSI/SPI2007 UL standard + NPPA and ANSI Z535 complianceHigh voltage symbolManual: English x1 and simple instruction manual x1Ejector specifications: SPI pattern and SPT spec ejector rodJoined ejector rod specificationNozzle tip: R12.7 (1/2”)Hopper throat temperature control Barrel cover (all-standard compliant)Hopper base4 hydraulic core pull circuits (stationary x2 and movable x2) and speed adjuster x1Password protectionCooling water circuit ball valve (all-point)Gate valve installationClamping pressure rise lampControl panel power interlockVoltage specifications: primary side AC460V (AC380-480V capable) 60Hz with grounding Operation power AC110V/DC24VNozzle and barrel heaters with grounding wiresBarrel heater power: 460VUS spec main power breakerToolsSpare parts (for export)
2021
123
45678910111213141516171819202122232425262728
29
12
3456
123
4
123
12345678910111213141516
171819202122
US specs (assembly)
Clamping unit/mold
Injection unit
Molding system control/production management
Cooling
Operation safety
Maintenance, installation, and miscellaneous
AUG. 2015
http://www.nisseiplastic.com/en
LOS ANGELES, CALIFORNIACORPORATE HEADQUARTERS
1480 North Hancock Street, Anaheim, CA 92807
CHICAGO, ILLINOIS TEL: (847)228-5000
JAMESBURG, NEW JERSEY TEL: (732)271-4885
ATLANTA, GEORGIA TEL: (770)421-0700
AUBURN, MASSACHUSETTS TEL: (508)754-5600
TAMPA, FLORIDA TEL: (727)773-8773TEL: (714)693-3000 FAX: (714)693-7777h t t p : / / w w w . n i s s e i a m e r i c a . c o m
Specifications, dimensions, designs, and other contents of this flyer are subject to change without notice due to continuous performance improvement.