2000
Item Nr. Description Unit 03 00 00 - CONCRETE 03 11 13 Structural Cast-in-Place Concrete Forming 1 m3 03 31 00 Structural Concrete 2 Reinforced concrete 35Mpa for strip footing m3 3 Reinforced concrete for sub structure for elevator pit m3 4 Reinforce concrete 35MPa for slab on grade with 7Ø8 / Liner meter thickness 150mm m3 5 Precost for super structure item Concrete Topping 6 Structural screed will wiremesh 50mm thick for floor above hollow core slab m2 7 Sand cement foam concrete on roof avarage 75mm thick m2 8 Concrete Pads m3 9 Sand cement screed for floors to receive finishing 50mm thick m2 03 30 53 - Miscellaneous Cast-in-situ Concrete 10 300mm wide x 150mm thick reinforced concrete lintel m 11 200mm wide x 150mm thick reinforced concrete lintel m Plain concrete 20MPa for blinding thickness 100mm for footing and 50mm under slab on grade

[XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Embed Size (px)

Citation preview

Page 1: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Item Nr. Description Unit Qty

03 00 00 - CONCRETE

03 11 13 Structural Cast-in-Place Concrete Forming

1 Plain concrete 20MPa for blinding thickness 100mm for footing and 50mm under slab on grade m3 36

03 31 00 Structural Concrete

2 Reinforced concrete 35Mpa for strip footing m3 103

3 Reinforced concrete for sub structure for elevator pit m3 4

4 Reinforce concrete 35MPa for slab on grade with 7Ø8 / Liner meter thickness 150mm m3 64

5 Precost for super structure item 1

Concrete Topping

6 Structural screed will wiremesh 50mm thick for floor above hollow core slab m2 1303

7 Sand cement foam concrete on roof avarage 75mm thick m2 363

8 Concrete Pads m3 8

9 Sand cement screed for floors to receive finishing 50mm thick m2 940

03 30 53 - Miscellaneous Cast-in-situ Concrete

10 300mm wide x 150mm thick reinforced concrete lintel m 57

11 200mm wide x 150mm thick reinforced concrete lintel m 23

Page 2: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for CONCRETE

CARRIED TO SUMMARY

04 00 00 - Masonry

04 22 00 - Concrete Unit Masonry

Internal walls and Partitions

1 100mm thick CMU wall, non fire rated m2 554

2 200mm thick CMU wall 2hr fire rated, m2 33

3 100mm thick CMU wall 2hr fire rated m2 119

4 200mm thick CMU wall 1hr fire rated, m2 78

5 200mm thick non fire rated m2 17

Page 3: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for MASONRY

CARRIED TO SUMMARY

Page 4: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

05 00 00 METALS

All metal works herein shall be completed full incompliance with the Drawings A0-

A402. and Specification.

05 70 00 Decorative Metal

1 Supply and fix 50mm diameter stainless steel hand rails including but not limited to m 20

12mm diameter stainless steel balustrade, 40mm square stainless steel post with 50mm

x 120mm base plate, for staircase, floor mounted, kind, quality, fittings, fixtures,

accessories as shown on Drawing nr A0-A402 and as per Specification.

m 20

2 Supply and fix 50mm diameter stainless steel hand rails for staircase, wall mounted,

kind, quality, fittings, fixtures, accessories as shown on Drawing nr A0-A402 and as per

Specification.

3 Supply and fix Aluminum powder coated balustrade & railing for balconies, floor m 70

mounted as shown on drawings and as per Specification

Additional Items

4 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

As per Question and Answer No. (393)

4.1 Anti-slip nosing strip as per Dwg # A402 LM 84

As per Question and Answer No (65)

4.2 Galvanized steel ladder @ elevator pit as shown in dwg No. (A1-A701) nr 1

Page 5: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for METALS

CARRIED TO SUMMARY

06 00 00 WOOD, PLASTICS, AND COMPOSITES

All works herein shall be completed full incompliance with the Drawings A1-A801, A1-

A802 and A1-A803 and Specification.

06 41 00 Architectural Wood Casework

As per Question and Answer No. (89) the kitchen cabinet changed to Aluminum

1 Supply and fit O/A size 2800 X 900mm kitchen base cabinet with lower adjustable shelf, nr 10

polished chrome cabinet pull handles; quality, fittings, fixtures, accessories, painting etc.

as shown on Drawings and as per Specification

2 Supply and fit O/A size 1000 X 900mm kitchen wall cabinet MDF melamine laminated nr 20

with aluminum edge banding to line up with SS cooker hood and polished chrome

cabinet pull handles (quality, fittings, fixtures, accessories, painting etc. as shown on

Drawings and as per Specification)

3 Supply and fit built-in closet - BIC02, O/A size width 1250mm, depth 600mm, height nr 4

2400mm complete with door painted by white matt lacquer finish, shelves MDF

laminated with dark wood veneer and handles chrome, gap between ceiling and top of

the cupboard to be infilled with stud and gypsum board with paint; (fittings,

fixtures, accessories, painting etc. as shown on Drawings and as per Specification)

4 Ditto - BIC01, O/A size width 2850mm, depth 600mm, height 2400mm. nr 14

5 Ditto - BIC03, O/A size width 2500mm, depth 600mm, height 2400mm. nr 14

06 61 16 Solid Surfacing Fabrications

Page 6: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

7 Counter tops w/ solid, non-porous, homogeneous surfacing material, composed acrylic nr 2

resin include sink opening and O/A size 2975x6000mm in kitchen.

8 Ditto - O/A size 2525x600mm. nr 2

9 Ditto - O/A size 3025x575mm. nr 6

10 Ditto - in bathroom wash basin opening O/A size 1100x550mm. nr 10

11 Ditto - O/A size 900x550mm. nr 6

12 Ditto - O/A size 610x400mm. nr 6

Solid Surfacing Fabrications (cont'd)

1 Ditto - Kitchen counter top O/A size 1200x400mm. nr 10 nr 10

Additional Items

Page 7: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Total

As per Question and Answer No. 353

2.1 MDF Laminated Shelf ; Size 3400mm length x 500mm high nr 6

Page 8: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for WOOD, PLASTICS, AND COMPOSITES

CARRIED TO SUMMARY

07 00 00 THERMAL AND MOISTURE PROTECTION

1 Two coats of bitumen paint for sub structure including elevator pit walls for vertical surface. m2 236

2 Ditto for horizontal surface m2 166

3 Vapour barrier 250 micron for horizontal surface m2 372

Wet Area Waterproofing

4 Waterproofing works for wet area, vertical surface m2 485

5 Ditto - horizontal surface. m2 160

Roof Waterproofing

6 Waterproofing and insulation works for roof; 100mm thick rigid insulation board and m2 315

geotextile layer on top; waterproofing membrane on horizontal surface, width > 300mm,

(quality, method of fixing, thickness as per the Drawings and Specification)

Roof Hatches

7 Roof hatch nr 1

8 Smook vent nr 1

9 Anti-vibration for loads at Roof m2 52

Page 9: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for THERMAL AND MOISTURE PROTECTION

CARRIED TO SUMMARY

08 00 00 OPENINGS

All works herein shall be completed in full compliance with the Doors & Windows Note

Schedule Drawings A0-A801, A0-A802, A0-A803 and Specification.

Note: Notwithstanding the Provisions of the Standard Method of Measurement, door

sets including doors, frames, vision panels, decoration and ironmongery have been

measured as a composite item and the Contractor should make due reference to the

drawings and specification. No claim for lack or want of knowledge will be entertained

08 13 00 Aluminum Doors

Page 10: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1 Supply and fix powder coated aluminum door type D4 and O/A size 1600 x 2975 mm, nr 1

weather tight strip, frame, including 600x2200 sidelight, 1600x775mm

fanlight,6+16+6mm laminated tempered glass, inside lock, ironmongery type HDH,

door closer type MO, and hardware with aluminum accessories as per drawings and

Specification

08 14 00 - Wood Doors

As Q&A No. 380

2 Supply, fix and 54mm thk.. flush teak veneer door including paint, architraves and nr 10

frame; half hour fire rated, comprises of 54mm thk.. well season and treated hardwood

frame solid core panel flush door with hardware type BBS hinges, dead lock, latch and

lever handles and door stop; O/A size 1000 X 2200 mm Type D1 (for detail refer the

schedules as per the Drawings and Specification).

3 Ditto - 44mm thick; O/A size 900 X 2200 mm Type D2. nr 22

4 Ditto - 44mm thk.. but excluding door stop; Type D3 and O/A size nr 24

800 x 2200mm.

5 Ditto - 54mm thick. including door closer MO, push bar/panic door and vision panel size nr 4

200x900mm. Type D5 and O/A size 1000 x 2200mm.

6 Ditto - 54mm thick. , door closer MO; Type D6 and O/A size 1000x2200mm. nr 4

7 Ditto - 54mm thick door closer MO, push bar/panic door and vision panel size nr 1

200x900mm. Type D7 and O/A size 1000 x 2200mm.

08 51 00 Aluminum Windows

8 Supply and fix powder coated aluminum window type W1 and O/A size 4300 x 1925 mm, nr 2

sliding leaves, fly screen leaves, weather tight strip, frame, double glazed, ironmongery,

and hardware with aluminum accessories. All as per specifications and drawings.

As per Question and Answer No. (67) aluminum shutter included in aluminum windows wherever required

Page 11: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1 Ditto - Type W2 and O/A size 4150 x 1925 mm . nr 2

2 Ditto - Type W3 with lock and O/A size 4300 x 3000 mm . nr 6

3 Ditto - Type W3a with lock and O/A size 4300 x 3000 mm . nr 8

4 Ditto - Type W4 with lock and O/A size 4150 x 3000 mm . nr 6

5 Ditto - Type W4a with lock and O/A size 4150 x 3000 mm . nr 8

6 Ditto - Type W12 with lock and handle, and O/A size 2550x3000mm. nr 3

7 Ditto - Type W13, and O/A size 2550x2500mm. nr 0

8 Ditto - Side hung single swing leaves Type W14, with fixed louvers and O/A size nr 26

650x1925mm.

08 83 00 Mirrors

9 Supply and fix mirror for bathrooms; O/A sizes 1000X1025mm (quality, surface nr 4

treatment, method of jointing, etc. as per the Drawing No. A1-903 and

Specification)

10 Ditto - O/A sizes 1100X1025mm. nr 6

11 Ditto - O/A sizes 900X1025mm. nr 6

Additional Items

13 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

including aluminum fixed shutter in front of slidding glss panels only and no glass balustrade is provided, refer to DWG. No. A0-802,A0-803 and A0-901

including aluminum fixed shutter in front of slidding glss panels only and no glass balustrade is provided, refer to DWG. No. A0-802,A0-803 and A0-901

Page 12: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for OPENINGS

CARRIED TO SUMMARY

09 00 00 - FINISHES

09 24 00 Cement Plastering

1 15mm thick internal plastering for Block walls to receive paint m2 1025

2 Ditto - for walls to receive tiling at wet areas, m2 138

09 23 00 Gypsum Board wall

3 Gypsum wall above wooden cabinet closet m2 51

Page 13: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836
Page 14: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Floor Tiling

1 Porcelain Stoneware tile flooring, ( Type FT1) size 600mm x 600mm, m2 1045

2 Terrazzo tiles size 400x400 mm at roof Terrace and water tank area m2 311

3 Porcelain Tile Threshold (Type FT-1) 200mm wide x 800mm length NR 24

Wall tiling

4 White Body wall tile (Type WT2) size 325mm x 977mm size for toilets and bathrooms m2 340

5 Ditto - Mosaic tile (Type WT4) for kitchen, size 100mmx300mm. m2 141

Skirting

6 MDF skirting 100mm height m 572

7 Porcelain skirting 100mm height for staircase m 95

8 Ditto for balcony 100mm height m 15

Stair Finish

9 Porcelain tile tread 280mm wide, 1100mm length, m 95

10 Ditto - riser 150mm height, 1100mm length. m 65

Stone Cladding

11 Grey sandstone slab above block for parapet at Ground Floor, size 35mm thick x 400mm wide. LM 19

Page 15: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

09 50 00 Ceilings

1 Supply and install gypsum ceiling, depth of suspension 500 - 1000 mm m2 425

as per dwg no.A1-A905 and A1-A901

2 Supply and install moisture gypsum board for ceiling at toilets, bathrooms, and kitchen m2 155

Painting

Wall -Painting

3 Painting for walls m2 1965

4 Painting for stair case walls m2 196

Ceiling -Painting

5 Painting for ceiling m2 378

6 Painting for stair case celing m2 17

7 Painting for gypsum board ceiling m2 580

Page 16: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

NOT USED

Page 17: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836
Page 18: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for FINISHES

CARRIED TO SUMMARY

10 00 00 SPECIALTIES

10 28 00 –Toilet, Bath and Laundry Accessories

All items hereunder to be described with , kind, quality, size, nature of base, method of

fixing , etc. as per the Drawings No A1-903 and Specification).

1 Soap dispenser (SD) nr 18

2 Towel bar nr 18

3 Towel ring nr 18

4 Robe hook nr 18

As per uestion and Answer No (62) 8mm thick tempered glass door and partition

5 Shower (SHO) nr 16

10 44 13.13 Portable Fire Extinguishers

All items hereunder to be described with , kind, quality, size, method of fixing , etc. as

per the Drawings and Specification).

6 Multipurpose dry chemical fire extinguisher nr 10

7 Supply & install fire blanket nr 10

10 00 00 Specialties

Page 19: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Additional Items

8 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

8.1 Toilet Paper Holder (TPH) nr 24

8.2 Towel Pin nr 16

Total for SPECIALTIES

CARRIED TO SUMMARY

11 00 00 EQUIPMENT

All items hereunder to be described with information such as appropriate to the

procurement , design, supply, execution, type, kind, quality, size, method of fixing ,

specified codes of practice, etc. as per the Drawings and Specification).

11 30 00 Residential Equipment

1 Exhaust hoods as per drawing and specification. nr 10

Page 20: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2 Trash compactors refer the specification. nr 1

Additional Items

3 The Contractor is to list here and price any items shown on the Drawings, mentioned in Item

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Page 21: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for EQUIPMENT

CARRIED TO SUMMARY

12 00 00 FURNISHING

All items hereunder to include supply, execution, type, kind, quality, size, method of

fixing etc. as per the appropriate codes of practice and as per the Drawings and

Specification

Additional Items

1 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Page 22: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for FURNISHING

CARRIED TO SUMMARY

14 00 00 - CONVEYING EQUIPMENT

14 10 10 - PASSENGER ELEVATORS

Contractor Designed Elevators

Supply and install 6 person passenger machine room less lift to serve four floors; refer

Specification for performance capacity, weight load, speed of travel, call system etc.; car

to include floor finish to be as per entrance hallway, mirrored and hardwood ceiling with

recessed and emergency lighting, mirrored and hardwood wall finish, chromium plated

handrails, floor indicator, floor push buttons (including braille floor indicators),

emergency call button/alarm, emergency intercom; each floor to have call button and

floor indicator all as manufacturers recommendations

1 Elevator nr 1

Page 23: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836
Page 24: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for CONVEYING EQUIPMENT

CARRIED TO SUMMARY

21 00 00 FIRE SUPPRESSION

All Fire suppression works herein shall be completed full incompliance with the Drawings

nr A1-M011, A1-M012, A1-F201, A1-F202, A1-F203, A1-F204 and Specification.

21 12 00 Fire Suppression Standpipes

Supply & Installation testing and commissioning of steel pipes (painted). All fire fighting

pipes to be completed including but not limited to accessories, fittings, couplings

according to NFPA code/ local civil defence code. Including all kind of supports and

hangers all in accordance to the specificaIons and drawings.

1 Ditto, 65 mm diameter m 27

21 11 19 Fire-Department Connection

5 Fire Connection Department including Non- return Valve, 65mm dia. nr 1

21 12 13 Fire-Suppression Hoses and Nozzles

Fire hose reel cabinet C/W 2-1/2" pressure restricted type landing valve 2-1/2"

synthetic hose, 1" automatic swinging hose reel, and multipurpose dry powder

extinguisher. The rate also shall be include all set of valves (landing , gate , angle,

PRV,etc.) , Pressure gauges.

7 Fire Hose Cabinet. nr 4

21 12 23 Fire-Suppression Hose Valves

Supply and installation valves complete and all necessary accessories, all in accordance

with the specifications and drawings.

12 Gate Valve , 65mm diameter nr 1

Automatic Air Vent

Supply and Installation of automatic air vent, all in accordance with the specifications

and drawings.

13 65 mm diameter. nr 1

Page 25: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

FIRE SUPPRESSION (Cont'd)

GENERAL

TESTING, ADJUSTING, AND BALANCING OF MEP SYSTEMS

1 Allow for Starting up, pressure testing, complete testing and commissioning for all Fire Item 1

fighting system, including all necessary preparations and attendance for authority

approvals.

2 Allow for drawing, manuals, approvals & instruction books. Item 1

3 Allow for protective and decorative painting Item 1

4 Allow for liaison and coordination with local authorities. Item 1

The contractor to list here and price any items shown in the drawings, mentioned in the

specifications or required for the satisfactory completion of this section as per the

relevant authority regulations, but not mentioned here. Any such item not listed is

deemed to be included.

Page 26: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

21 00 00 Fire Suppression

Additional Items

1 The Contractor is to list here and price any items shown on the Drawings, mentioned in Item

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Total for FIRE SUPPRESSION

CARRIED TO SUMMARY

22 00 00 - PLUMBING

Page 27: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

All items hereunder to be described specified code of practice and regulations, kind,

quality, size, method of fixing , finishes or surface treatments, etc. as per the Drawings

and Specification).

22 05 23 General-Duty Valves for Plumbing Piping

Valves

Valves are classified according to type . Material and/or size . Rates include furnishing

and installing of valves, testing at manufacturer's premises and on site; diameters of

valves and water meter according to pipe diameter which will be connected with it; as

per Drawings and Specification.

Gate Valve

1 20 mm diam. nr 4

2 25 mm diam. nr 48

3 32 mm diam. nr 6

4 40 mm diam. nr 16

5 75 mm diam. nr 2

6 90 mm diam. nr 4

Angle Valve

7 20 mm diam. nr 72

8 25 mm diam. nr 24

Check Valve

9 20 mm diam. nr 8

Globe Valve

10 20 mm diam. nr 2

11 25 mm diam. nr 24

12 40 mm diam. nr 2

Non-Return Valve

Page 28: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

13 32 mm diam. nr 2

14 40 mm diam. nr 8

63 mm diam. nr 2

Pressure Reducing Valve

15 90 mm diam. nr 1

PLUMBING (Cont'd)

22 11 16 Domestic Water Piping

Domestic water piping is classified by material and diameter. Rates include furnishing

and installing of pipes, fittings, accessories, fixing supports, joints, sleeves, special parts,

connections, hanger supports. Rates to include all works and materials necessary for

complete installation for piping system as per the Drawings and Specification.

Water Supply System

1-Cold Water Supply

1 90 mm diameter. m 30

2 75 mm diameter. m 23

3 63 mm diameter. m 12

4 40 mm diameter. m 22

5 32 mm diameter. m 7

6 25 mm diameter. m 428

7 20 mm diameter. m 265

2-Hot Water Supply

Page 29: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

8 20 mm diameter. m 212

3 - Accessories

9 Hose Bibb 20mm . nr 2

10 Water Meter 40 mm. nr 8

11 Water Meter 32 mm. nr 2

12 Water Hammer Arrestor nr 26

13 Automatic Air Vent. nr 26

14 Pressure Gauge . nr 2

15 Strainer 90 mm. nr 1

22 13 16 Sanitary Waste and Vent Piping

Sanitary Pipe Works

Sanitary pipe works is classified by material and diameter. Rates include furnishing and

installing of pipes, fittings, accessories, fixing support, joints, sleeves , special parts,

connections, hanger supports. Rates for pipework below ground also include

excavation, backfilling , civil work, trenches and any other accessories or fittings

necessary for complete installation of the piping system. Testing of pipes at the

manufacturer's premises is included. All as per the Drawings and Specification.

PLUMBING (Cont'd)

Pipes and fitting above ground

Waste Pipe

1 50 mm diameter. m 31

Page 30: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2 75 mm diameter. m 30

3 110 mm diameter. m 163

Soil Pipe

4 110 mm diameter. m 85

Pipes and fitting below ground

Waste pipe

5 75 mm diameter. m 5

6 110 mm diameter. m 54

Soil Pipe

7 110 mm diameter. m 105

Vent Pipe Works

Vent pipes are classified by material and diameter. Rates include furnishing and installing

of pipes, fittings, accessories, fixing support, joints, sleeves, special parts, connections,

hanger supports. Rates include furnishing and installing of pipes, fittings, accessories,

fixing support, joints, sleeves , special parts, connections, hanger supports. Rates for

pipework below ground also include excavation, backfilling , civil work, trenches and any

other accessories or fittings necessary for complete installation of the piping system.

Testing of pipes at the manufacturer's premises is included. All as per the Drawings and

Specification.

Pipes and fittings above ground

8 75 mm diameter. m 151

Pipes and fitting below ground

9 75 mm diameter. m 9

22 13 19.13 Sanitary Drains

Sanitary drains (to include rainwater pipework and condensate drain pipework) are

classified by material and diameter. Rates include furnishing and installing of pipes,

fittings, accessories, fixing supports, joints, sleeves, special parts, connections, hanger

supports. Rates also include testing of pipes at the manufacturer's premises. All as per

the Drawings and specification.

Page 31: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Rain water Pipe

10 75 mm diameter. m 150

PLUMBING (Cont'd)

Condensate Drain Pipe Works

1 20 mm diameter. m 135

2 25 mm diameter. m 18

22 33 00 Electric Domestic Water Heaters

Electric domestic water heaters are classified according to capacity. Rates include

furnishing of heater complete with safety valves, air vent, pressure and temperature

relief gauges, drain valves, all valves set (angle, gate, non return, etc. .), thermostat,

heating element, contactors, switch, support, bolts, nuts, connection of pipes, testing on

3 EWH-A1-01 with (30 litres / 1200 W) capacity. nr 18

4 EWH-A1-02 with (100 litres / 1500 W) capacity. nr 16

22 40 00 Plumbing Fixtures

All items described hereunder to be of kind, quality, size, nature of base, method of

fixing, complete with accessories etc. as per the Drawings nr V1-903 and Specification

5 Floor Drain (FD) nr 38

6 Flexible Shower Hose(Sprayer ,valve , etc.) nr 24

7 Water Closet nr 24

8 Floor clean out nr 4

9 Roof drain nr 9

10 Vent cap nr 6

Page 32: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

11 Bath tub (BT) including taps, plug, accessories and fitting. nr 0

12 Wash basin (WB) nr 24

As per question & answer no. 358,clothes washwer not in contract only connection

13 Washing machine connections (washing machine not in contract) nr 10

As per question & answer no. 360,shower channel to be used

14 Shower (SHO) including shower channel, mixer tap, fitting, spray and adjustable bar nr 16

setting

PLUMBING (Cont'd)

1 Kitchen sink nr 10

2 Taps for wash basin including fittings , plugs, valves, connections and waste. nr 24

3 Mixer tap for kitchen sink including fitting, plugs, chrome plated pipes, valves and nr 10

waste

22 00 00 - Plumbing

Additional Items

Page 33: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

4 Inspection chamber as per Drawings and Specification; connected directly to nr 9

sewer network.

5 Clean out (CO) nr 24

6 Roof Water tank as per Specification; rate shall be include supplying and nr 2

installing, all fittings, accessories, valves, pipework, vents etc. as per the Drawings

and Specification

7 Balcony Drain nr 12

8 Gully Trap nr 6

Additional Items

9 Marking the position of holes, mortices and chases in the structure Item 1

10 Identification; plates, discs, labels, tapes, bands, arrows, symbols, letters, numbers and Item 1

charts; as stated on drawings and in Specification

11 Testing and commissioning of entire installation Item 1

12 Preparation of as-built drawings Item 1

13 Preparation of operation and maintenance manuals Item 1

14 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Page 34: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for PLUMBING

CARRIED TO SUMMARY

23 00 00 - HEATING, VENTILATING, AND AIR CONDITIONING (HVAC)

All HVAC works shall be completed as per the Drawings and Specification.

23 07 13 Duct Insulations

All items hereunder to be described with in type, kind, quality, thickness, method of

fixing , specified codes of practice, etc. as per the Drawings and Specification).

1 Supply and fix ductwork insulations outdoor for (supply, return, fresh air, exhaust, etc.); m2 245

air duct to include fixing and accessories as per the Drawings and Specification

23 23 00 Refrigerant Piping

Supply and fix refrigerant pipes for FCU from condensing units to indoor installed AC

units including fittings, sleeves and all accessories as per the Drawings and Specification

2 20 mm diameter with max liquid line 10 mm. m 445

23 31 00 HVAC Ducts and Casings

All items hereunder to be described with in type, kind, quality, size, method of fixing ,

specified codes of practice, placing and method of fixing supports, etc. as per the

Drawings and Specification).

Notwithstanding the provisions of the Standard Method of Measurement, internal

ductwork is to include insulation to the ductwork. No claim for additional cost due to

lack or want of knowledge will be entertained

3 Supply and fix insulated indoor galvanized steel sheet metal duct work for all HVAC work Kg 2443

as specified and as indicating on drawings, complete with bends, supports, connections,

fittings, splices and all accessories to complete the work.

Page 35: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

HEATING, VENTILATING, AND AIR CONDITIONING (Cont'd)

23 33 13.13 Volume-Control Dampers

All items hereunder to be described with ,type, kind, quality, size, method of fixing ,

specified codes of practice, etc. as per the Drawings and Specification).

Volume Dampers

1 Volume Damper ; 100x100 mm . nr 22

2 Volume Damper ; 150x100 mm . nr 6

3 Volume Damper ; 150x150 mm nr 6

4 Volume Damper ; 150 mm dia. circular damper. nr 10

5 Volume Damper ; 200x150 mm . nr 2

Page 36: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

6 Volume Damper ; 200x200 mm . nr 4

7 Volume Damper ; 300x200 mm . nr 2

8 Volume Damper ; 300x300 mm . nr 2

9 Volume Damper ; 400x150 mm . nr 2

10 Volume Damper ; 400x300 mm . nr 16

11 Volume Damper ; 400x350 mm . nr 12

12 Volume Damper ; 400x400 mm . nr 4

13 Volume Damper ; 500x400 mm . nr 8

Splitter Dampers

14 Splitter Damper nr 1

23 33 13.16 Fire Dampers

As per Q&A no. 362 the word 'motorized' to be deleted in the description

All items hereunder to be described with information such as type, kind, quality, size,

method of fixing , specified codes of practice, etc. as per the Drawings and Specification).

15 Fire Damper ; Size 100 x 100 mm. nr 12

16 Fire Damper ; Size 100 x 150 mm. nr 6

17 Fire Damper ; Size 150 x 150 mm. nr 6

23 33 46 Flexible Ducts

All items hereunder to be described with in type, kind, quality, size, method of fixing ,

specified codes of practice, placing and method of fixing supports, etc. as per the

Drawings and Specification).

18 Supply and install Flexible duct with insulation ; size diam. 150 mm . m 6

Page 37: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

HEATING, VENTILATING, AND AIR CONDITIONING (Cont'd)

23 34 00 HVAC Fans

All items hereunder to be described with information such as appropriate to the

procurement , capacity, design, supply, execution, type, kind, quality, size, method of

fixing , specified codes of practice, etc. as per the Drawings and Specification).

Supply and install Exhaust fan as specified and as indicated in drawing. Fan consists of

casing, fan, motor, control, filter, screen, sand trap louver, all electrical works

(components, wiring, etc.) and all accessories. Electrical power supply 220/1/60.

Wall Mounted

1 Exhaust Fan (EF-01) 50 Pa with total air flow 50 L/S . nr 10

Ceiling Mounted

2 Exhaust Fan (EF-02 ) 100 Pa with total air flow 25 L/S . nr 24

Range Hood Fan

3 Range Hood Fan (RH-01) ;150 Pa with total air flow 50 L/S . nr 10

Garbage Exhaust fan

4 Garbage Exhaust fan (GEF-01/GEF-02) ;250 Pa with total air flow 80 L/S . nr 2

23 37 00 Air outlets and Inlets

All items hereunder to be described with information such as type, kind, quality, size,

method of fixing , specified codes of practice, etc. as per the Drawings and Specification).

Supply and install Painted Supply linear bar air Register with complete accessories.as

per the Drawings and Specification.

5 Size 450x200 mm ; 260 L/s . nr 2

6 Size 500x200 mm ; 280 L/s . nr 2

7 Size 500x200 mm ; 460 L/s . nr 2

8 Size 600x200 mm ; 470 L/s . nr 2

9 Size 650x200 mm ; 265 L/s. nr 4

Page 38: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

10 Size 750x200 mm ; 300 L/s. nr 2

11 Size 750x250 mm ; 365 L/s. nr 2

12 Size 800x200 mm ; 310 L/s . nr 2

13 Size 800x200 mm ; 315 L/s . nr 2

14 Size 850x200 mm ; 345L/s . nr 4

15 Size 850x250mm ; 400L/s . nr 2

16 Size 1050x200 mm ; 440L/s . nr 4

17 Size 1050x250 mm ; 520L/s . nr 2

HEATING, VENTILATING, AND AIR CONDITIONING (Cont'd)

Supply and install Painted Return linear bar air grille with complete accessories.as per

the Drawings and Specification.

1 Size 450x200 mm ; 260 L/s . nr 2

2 Size 500x200 mm ; 280 L/s . nr 2

3 Size 500x200 mm ; 460 L/s . nr 2

4 Size 600x200 mm ; 470 L/s . nr 2

5 Size 650x200 mm ; 265 L/s. nr 4

6 Size 750x200 mm ; 300 L/s. nr 2

7 Size 750x250 mm ; 365 L/s. nr 2

8 Size 800x200 mm ; 310 L/s nr 2

9 Size 800x200 mm ; 315 L/s nr 2

10 Size 850x200 mm ; 345L/s . nr 4

Page 39: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

11 Size 850x250mm ; 400L/s . nr 2

12 Size 1050x200 mm ; 440L/s . nr 4

13 Size 1050x250 mm ; 520L/s . nr 2

Supply and install 3 way Supply ceiling diffuser with complete accessories.as per the

Drawings and Specification.

14 Size 150X150 mm ; 40 L/s. nr 10

Supply and install exhaust air louver with complete accessories as per the Drawings

and Specification.

15 Exhaust air louver (150X100)mm . nr 24

16 Exhaust air louver (200X150)mm . nr 10

23 82 00 Convection Heating and Cooling Units

All items hereunder to be described with information such as appropriate to the

procurement , capacity, design, supply, execution, type, kind, quality, size, method of

fixing , specified codes of practice, etc. as per the Drawings and Specification).

Supply and install fresh air handing unit as specified and as indicated in drawing. Unit

to be complete with air cooled condensing unit, fan, pre-filter, bag filter, damper and

sand trap louver with filter, valves, controls, all electrical works (components, wiring ,

etc.) and all accessories. Electrical power supply 380/3/60

17 FAHU-A1-01) , 840 L / s , 350 Pa ; Total load 33.2 KW . nr 1

HEATING, VENTILATING, AND AIR CONDITIONING (Cont'd)

Supply and install concealed fan coil unit as specified and as indicated on drawings.

Unit to be complete with air cooled condensing unit, fan, filter, valves, control,

Page 40: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

thermostat, all electrical works (components , wiring , etc. .) and all accessories.

Electrical power supply 220/1/60.

Ground Floor

1 (FCU-GF1-01) , 260 L / s , 75 Pa ; Electrical data power 1.8 KW . nr 1

2 (FCU-GF1-02) , 472 L / s , 75 Pa ; Electrical data power 3.6 KW . nr 1

3 (FCU-GF2-01) , 261 L / s , 75 Pa ; Electrical data power 1.8 KW . nr 1

4 (FCU-GF2-02) , 472 L / s , 75 Pa ; Electrical data power 3.6 KW . nr 1

5 (FCU-GF3-01) , 282 L / s , 75 Pa ; Electrical data power 1.8 KW . nr 1

6 (FCU-GF3-02) , 462 L / s , 75 Pa ; Electrical data power 3.6 KW . nr 1

7 (FCU-GF4-01) , 283 L / s , 75 Pa ; Electrical data power 1.8 KW . nr 1

8 (FCU-GF4-02) , 461 L / s , 75 Pa ; Electrical data power 3.6 KW . nr 1

First and Second Floor

9 (FCU-TF1-01) , 480 L / s , 75 Pa ; Electrical data power 3.6 KW . nr 2

10 (FCU-TF1-02) , 343 L / s , 75 Pa ; Electrical data power 2.7 KW . nr 2

11 (FCU-TF1-03) , 314 L / s , 75 Pa ; Electrical data power 2.7 KW . nr 2

12 (FCU-TF1-04) , 265 L / s , 75 Pa ; Electrical data power 1.8 KW . nr 2

13 (FCU-TF2-01) , 480 L / s , 75 Pa ; Electrical data power 3.6 KW . nr 2

14 (FCU-TF2-02) , 344 L / s , 75 Pa ; Electrical data power 2.7 KW . nr 2

15 (FCU-TF2-03) , 314 L / s , 75 Pa ; Electrical data power 1.8 KW . nr 2

16 (FCU-TF2-04) , 265 L / s , 75 Pa ; Electrical data power 1.8 KW . nr 2

HEATING, VENTILATING, AND AIR CONDITIONING (Cont'd)

Third Floor

17 (FCU-LF1-01) , 558 L / s , 75 Pa ; Electrical data power 3.6 KW . nr 1

18 (FCU-LF1-02) , 395 L / s , 75 Pa ; Electrical data power 2.7 KW . nr 1

19 (FCU-LF1-03) , 365 L / s , 75 Pa ; Electrical data power 2.7 KW . nr 1

Page 41: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

20 (FCU-LF1-04) , 301 L / s , 75 Pa ; Electrical data power 1.8 KW . nr 1

21 (FCU-LF2-01) , 559 L / s , 75 Pa ; Electrical data power 3.6 KW . nr 1

22 (FCU-LF2-02) , 396 L / s , 75 Pa ; Electrical data power 2.7 KW . nr 1

23 (FCU-LF2-03) , 366 L / s , 75 Pa ; Electrical data power 2.7 KW . nr 1

24 (FCU-LF2-04) , 301 L / s , 75 Pa ; Electrical data power 1.8 KW . nr 1

HEATING, VENTILATING, AND AIR CONDITIONING (Cont'd)

23 05 93 Testing, Adjusting and Balancing for HVAC

All items hereunder to be described with type of installation, preparatory operations,

stages of test (nr), required attendance, applicable codes etc. as per the Drawings and

Specification).

1 Air balancing of the ducting network Item 1

2 Testing, balancing and commissioning of all the equipment Item 1

23 00 00 - Heating, Ventilating, and Air Conditioning (HVAC)

Additional Items

3 Marking the position of holes, mortices and chases in the structure Item 1

4 Identification; plates, discs, labels, tapes, bands, arrows, symbols, letters, numbers and Item 1

charts; as stated on drawings and in Specification

5 Testing and commissioning of entire installation Item 1

6 Preparation of as-built drawings Item 1

7 Preparation of operation and maintenance manuals Item 1

8 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Page 42: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

8.01 Exhaust air Grille (100X100)mm . nr 4

8.02 Fresh air Grille (250X200)mm . nr 1

Total for HVAC

CARRIED TO SUMMARY

26 00 00 - ELECTRICAL

All works hereunder shall be completed as per the Drawings and Specification.

26 05 19 Low Voltage Electrical Power Conductors and cables

All items hereunder to be of type, kind, number of cores, armoring and sheathings,

method of fixing , specified codes of practice, etc. as per the Drawings and Specification).

Notwithstanding the Provisions of the method of measurement, cables have been

Page 43: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

itemized and referenced to the circuit. The contractor is to make due reference to

drawings nrs.. E000, E001, E002, E003, ELV201, EL201, EP201, LP201, PS301, PS302,

E401, E402 and E403 for full details and is to allow for all cabling, junctions, flexible

connections, feeder units etc. required to complete the installation in accordance with

the drawings and Specification. No claim for want or lack of knowledge will be

entertained

1 Lighting circuits Item 1

2 Power circuits Item 1

3 Fire alarm circuits Item 1

4 Cooker circuits Item 1

5 Water heater circuits Item 1

6 Fan circuits Item 1

7 Outdoor lighting circuits Item 1

8 HVAC control circuits Item 1

9 Emergency lighting circuits Item 1

10 Lift power circuits Item 1

Page 44: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

ELECTRICAL (Cont'd)

1 Lightning protection Item 1

26 05 26 Grounding and Bonding for Electrical Systems

All items hereunder to be described with information such as type, kind, number of

cores, armoring and sheathings, method of fixing , specified codes of practice, etc. as per

the Drawings and Specification).

2 grounding system Item 1

26 05 33.13 Conduit for Electrical Systems

All items hereunder to be described with information such as type, kind, , method of

fixing , specified codes of practice, etc. as per the Drawings and Specification).

Notwithstanding the Provisions of the method of measurement, conduits have been

itemized and referenced to the circuit. The contractor is to make due reference to

drawings nrs.. E000, E001, E002, E003, ELV201, EL201, EP201, LP201, PS301, PS302,

E401, E402 and E403 for full details and is to allow for all cabling, junctions, flexible

connections, feeder units etc. required to complete the installation in accordance with

the drawings and Specification. No claim for want or lack of knowledge will be

entertained

3 Lighting circuits Item 1

4 Power circuits Item 1

5 Fire alarm circuits Item 1

6 Cooker circuits Item 1

7 Water heater circuits Item 1

8 Fan circuits Item 1

Page 45: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

9 Outdoor lighting circuits Item 1

ELECTRICAL (Cont'd)

1 HVAC control circuits Item 1

2 Emergency lighting circuits Item 1

3 Lift power circuits Item 1

4 Lightning protection Item 1

26 24 13 Switchboards

All items hereunder to be described with information such as type, kind, rated capacity,

method of fixing, cores reference to Specification, fuses, background, specified codes of

practice, etc. as per the Drawings and Specification).

Page 46: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

26 24 16 Panel boards

All items hereunder to be described with information such as type, kind, rated capacity,

method of fixing, cores reference to Specification, fuses, codes of practice, etc. as per

the Drawings and Specification).

5 Sub-main distribution boards Item 1

26 27 13 Electricity Metering

6 All items hereunder to be described with information such as type, kind, rated capacity, Item 1

method of fixing, cores reference to Specification, fuses, codes of practice, etc. as per

the Drawings and Specification).

26 27 26 Wiring Devices

Switches & Push Buttons

All items hereunder to be described with information such as appropriate to the

procurement , type, kind, quality, size, method of fixing , specified codes of practice, etc.

as per the Drawings and Specification).

7 One way one gang switch nr 69 nr 69

Page 47: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

ELECTRICAL (Cont'd)

1 1 One way two gang switch nr 26 nr 26

Power Outlets

4 Single outlet nr 44

5 Double outlet nr 87

6 Double outlet; NEMA 5-18R; weather proof grounding type nr 10

7 Single point shaver outlet nr 20

8 Single point kitchen hood outlet nr 14

10 Fusible disconnect switch plate, double poles, 32A, 220V, 60HZ, with lamp Indicator for nr 33

water heater

11 Fusible disconnect switch plate, double poles, 32A, 220V, 60HZ, with lamp Indicator for nr 26

air conditioning

12 Fusible disconnect switch plate, double poles, 32A, 220V, 60HZ, with lamp Indicator for nr 10

refrigerator (NORMAL SOCKET OUTLET AS PER Q&A # 539)

13 nr 26

14 Fusible disconnect switch plate, double poles, 30A, 220V, 60HZ for exhaust ceiling fan nr 24

15 Fusible disconnect switch plate, double poles, 30A, 220V, 60HZ for wall mounted nr 10

exhaust fan

Fusible disconnect switch plate, double poles, 30A, 220V, 60HZ for TV (NORMAL SOCKET OUTLET AS PER Q&A # 539)

Page 48: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

ELECTRICAL (Cont'd)

26 50 00 Lighting

All items hereunder to be described with information such as appropriate to the

procurement , type, kind, quality, size, method of fixing , specified codes of practice, etc.

as per the Drawings and Specification).

1 Luminaire, ceiling mounted, satin steel/nickel/plastic, white diffuser; type B2 nr 16

2 Luminaries, downlight, compact fluorescent lamp with glass cover, 1 x 26W CFL; type D1 nr 68

3 Luminaries, recess mounted downlight, compact fluorescent lamp with glass cover, 1 x nr 32

26W CFL; type D2

4 Luminaire, ceiling mounted, with semi sphere opal bowl diffuser; 1 x 18W, 220V, 60hz; nr 20

type R2

5 Luminaire, power light, steel/chrome/plastic, white, 1 x 50W; type S2 nr 64

6 Luminaire, ceiling mounted, square shaped, 4 x 50W; type S3 nr 16

Page 49: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

7 Luminaire, wall mounted 1 x 26W CFL with glass cover; type W1 nr 2

8 Luminaire, wall mounted fluorescent, steel chrome/plastic, white 2 x 26W; type W2 nr 24

9 Luminaire, up/down wall mounted; 1 x 26W CDL; type W3 nr 10

10 Luminaire, wall mounted CDL; 1 x 26W with aluminum dome reflector; type W4 nr 16

11 Luminaire, wall mounted satin nickel/plastic, white; 1 x 18W CDL; type W5 nr 10

12 Luminaire, self contained exit light with directional arrow nr 5

ELECTRICAL (Cont'd)

Page 50: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Additional Items

1 Marking the position of holes, mortices and chases in the structure Item 1

2 Identification; plates, discs, labels, tapes, bands, arrows, symbols, letters, numbers and Item 1

charts; as stated on drawings and in Specification

3 Testing and commissioning of entire installation Item 1

4 Preparation of as-built drawings Item 1

5 Preparation of operation and maintenance manuals Item 1

6 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

6.1 Power supply cables from Electric meters to Distribution boards ( as per O&A 537) Item 1

6.2 Cable trays for electrical system m 78

6.3 Cable ladders for electrical system m 25

Page 51: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for ELECTRICAL

CARRIED TO SUMMARY

Telecommunication / Low Current

STRUCTURED CABLING SYSTEM

Supply, Install, Test, connect and commission inclusive of all cabling, conduits and

containment, socket outlets, all in accordance with the relevant service provider regulations

, rules, recommendation and requirements and in accordance with the specifications and

drawings.

1 Information Outlet, Flush Type 1 DATA, 1 Telephone 0.3 Meters A.F.F.L. nr 26

2 Telephone Outlet, Wall Mounted Flush Type, MTD 0.30m A.F.F.L nr 16

3 Telephone Outlet, Wall Mounted, Flush Type 1.2 Meters A.F.F.L. nr 10

4 TV outlet, wall mounted nr 26

5 9U Telecom Cabinet, Wall Mounted nr 10

6 Intercom Outlet, wall mounted nr 10

7 Optical Distribution box nr 1

8 Set Top Box nr 26

9 LED TV nr 26

10 CAT 6A, UTP Cable m 970

Page 52: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

11 Single Mode Fiber Optic Cable - 1 x 24 Core m 150

Video Entry System / Intercom

Supply, Install, Test, connect and commission inclusive of all cabling, conduits and

containment, socket outlets, all in accordance with the relevant service provider regulations

, rules, recommendation and requirements and in accordance with the specifications and

drawings.

12 Main Entrance Station nr 1

13 Residential Main Station / Intercom Outlet nr 10

14 CAT 6A, UTP Cable m 210

Consumption Metering

Supply, Install, Test, connect and commission inclusive of all cabling, conduits and

containment, socket outlets, all in accordance with the relevant service provider regulations

, rules, recommendation and requirements and in accordance with the specifications and

drawings.

1 Metering Receiver nr 1

Page 53: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2 M-bus Cable, 2 x 18AWG m 55

Fire Alarm System

Supply, install, connection, testing and commissioning of wiring and equipment for Fire

Alarm System including all necessary materials and accessories to reflect complete

system installation.

3 Addressable, smoke detector nr 17

4 Addressable, smoke detector with sound base nr 14

5 Addressable, heat detector nr 14

6 Addressable, Manual Pull Station nr 14

7 Fire Alarm Horn With Strobe nr 14

8 Fault Isolator nr 5

9 Control Module nr 5

10 Fire Alarm Control Panel nr 1

11 Power Supply Unit, 24v nr 1

12 Loop Cable, 2x1.5mm2 Fire Resistant m 400

13 24V Cable, 2x2.5mm2 Fire Resistant m 130

Additional Items

The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

ADDITIONAL (As per Q&A Log 19, 343)

13.1 Single Mode Fiber Optic Cable - 1 x 2 Core m 215

13.2 ACTIVE COMPONENTS (AS PER Q&A 487) m 10

Page 54: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for COMMUNICATIONS

CARRIED TO SUMMARY

31 00 00 EARTHWORK

All works herein shall be completed in full compliance with the Drawings nr A-S001,AS002,

A-S003,A-S004,A-S005,A-S401and Specification.

31 10 00 Site Clearing

1 Site preparation, clearing site vegetation m2 392

31 23 16 Excavation

2 Excavating top soil for preservation, average depth 150mm. m2 392

3 Excavating pits(17 nr), maximum depth ≤ 2.00m. m3 463

4 Excavating trenches for grade beams, width ≤ 0.3m m3 21

31 23 23 .13 Backfill

5 Filling to excavations, average thickness > 0.25 m, arising from excavated materials, all m3 203

fill shall be compacted to 75% relative density for cohesionless soils as per ASTM

D4254/ASTM D4293 or 95% maximum density as determined by ASTM D698 for

cohesive material, as per the Drawings and Specifications

31 23 23.23 Compaction

7 Surface treatments, compacting bottom of excavation (method of filling and m2 638

compactions to be stated as per the Drawings and Specifications)

31 23 16.26 Rock Removal

6 Disposal of excavated material, off site as stated in the Specification. m3 339

Page 55: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

31 31 16 Termite Control

8 Termite control for the horizontal surface (method and type of treatment as per the m2 638

Drawings and Specifications)

9 Termite control for vertical surface (method and type of treatment as per the Drawings m2 676

and Specifications)

Additional Items

3 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Page 56: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836
Page 57: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for EARTHWORK

CARRIED TO SUMMARY

03 00 00 Concrete

04 00 00 Masonry

05 00 00 Metal

06 00 00 Wood, Plastics and Composites

07 00 00 Thermal and Moisture Protection

08 00 00 Openings

09 00 00 Finishes

10 00 00 Specialties

11 00 00 Equipment

12 00 00 Furnishing

14 00 00 Conveying Equipment

21 00 00 Fire Suppression

22 00 00 Plumbing

23 00 00 Heating, Ventilating and Air Conditioning (HVAC)

26 00 00 Electrical

27 00 00 Communications

31 00 00 Earthwork

SUBTOTAL

MULTIPLY BY 46 BLOCKS 46

Page 58: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

AMOUNT FOR APARTMENT TYPE A1 TO SUMMARY

Page 59: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Rate Amount

164.00 5,904.00

380.00 39,140.00

656.00 2,624.00

296.00 18,944.00

538070.00 538,070.00

25.00 32,575.00

17.00 6,171.00

310.00 2,480.00

17.00 15,980.00

15.00 855.00

10.00 230.00

Page 60: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

662,973.00

662,973.00

34.00 18,836.00

55.00 1,815.00

42.00 4,998.00

55.00 4,290.00

35.00 595.00

Page 61: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

30,534.00

Page 62: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

294.00 5,880.00

113.00 2,260.00

143.00 10,010.00

20.00 1,680.00

283.00 283.00

Page 63: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

20,113.00

3960.00 39,600.00

966.00 3,864.00

2201.00 30,814.00

1931.00 27,034.00

Page 64: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1052.00 2,104.00

893.00 1,786.00

1070.00 6,420.00

396.00 3,960.00

341.00 2,046.00

229.00 1,374.00

119,002.00

119,002.00

261.00 2,610.00

Page 65: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

576.00 3,456.00

Page 66: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

125,068.00

5.00 1,180.00

5.00 830.00

2.00 744.00

22.00 10,670.00

22.00 3,520.00

61.00 19,215.00

514.00 514.00

2966.00 2,966.00

34.00 1,768.00

Page 67: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

41,407.00

41,407.00

Page 68: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2886.00 2,886.00

1460.00 14,600.00

1211.00 26,642.00

1211.00 29,064.00

2171.00 8,684.00

1692.00 6,768.00

2497.00 2,497.00

6075.00 12,150.00

Page 69: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

103,291.00

103,291.00

5905.00 11,810.00

9410.00 56,460.00

7574.00 60,592.00

9081.00 54,486.00

7310.00 58,480.00

5447.00 16,341.00

827.00 21,502.00

89.00 356.00

97.00 582.00

82.00 492.00

Page 70: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

384,392.00

22.00 22,550.00

21.00 2,898.00

55.00 2,805.00

Page 71: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836
Page 72: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

28,253.00

28,253.00

55.00 57,475.00

32.00 9,952.00

44.00 1,056.00

72.00 24,480.00

53.00 7,473.00

17.00 9,724.00

19.00 1,805.00

19.00 285.00

24.00 2,280.00

20.00 1,300.00

102.00 1,938.00

Page 73: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

117,768.00

117,768.00

54.00 22,950.00

56.00 8,680.00

11.00 21,615.00

11.00 2,156.00

11.00 4,158.00

11.00 187.00

11.00 6,380.00

Page 74: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

66,126.00

66,126.00

Page 75: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836
Page 76: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

212,147.00

22.00 396.00

31.00 558.00

35.00 630.00

17.00 306.00

680.00 10,880.00

54.00 540.00

76.00 760.00

Page 77: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

21.00 504.00

17.00 272.00

14,846.00

465.00 4,650.00

Page 78: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836
Page 79: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

4,650.00

Page 80: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

0.00

47027.00 47,027.00

Page 81: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836
Page 82: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

47,027.00

52.00 1,404.00

552.00 552.00

3082.00 12,328.00

503.00 503.00

96.00 96.00

Page 83: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

14,883.00

14,883.00

205.00 205.00

Page 84: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

15,088.00

Page 85: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

20.00 80.00

25.00 1,200.00

34.00 204.00

48.00 768.00

191.00 382.00

235.00 940.00

19.00 152.00

68.00 136.00

72.00 1,728.00

159.00 318.00

Page 86: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

40.00 80.00

45.00 360.00

0.00

93.00 186.00

1720.00 1,720.00

8,254.00

8,254.00

120.00 3,600.00

98.00 2,254.00

72.00 864.00

48.00 1,056.00

39.00 273.00

25.00 10,700.00

18.00 4,770.00

Page 87: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

16.00 3,392.00

29.00 58.00

1576.00 12,608.00

1237.00 2,474.00

46.00 1,196.00

96.00 2,496.00

46.00 92.00

240.00 240.00

46,073.00

46,073.00

11.00 341.00

Page 88: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

17.00 510.00

29.00 4,727.00

37.00 3,145.00

28.00 140.00

37.00 1,998.00

37.00 3,885.00

17.00 2,567.00

28.00 252.00

Page 89: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

17.00 2,550.00

20,115.00

20,115.00

9.00 1,215.00

10.00 180.00

275.00 4,950.00

322.00 5,152.00

192.00 7,296.00

38.00 912.00

313.00 7,512.00

202.00 808.00

171.00 1,539.00

43.00 258.00

Page 90: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

41.00 410.00

292.00 4,672.00

34,904.00

34,904.00

166.00 3,984.00

425.00 4,250.00

Page 91: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

636.00 5,724.00

11.00 264.00

2841.00 5,682.00

458.00 2,748.00

818.00 818.00

7060.00 7,060.00

30,530.00

Page 92: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

139,876.00

52.00 12,740.00

31.00 13,795.00

12.00 29,316.00

Page 93: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

55,851.00

55,851.00

54.00 1,188.00

56.00 336.00

58.00 348.00

58.00 580.00

60.00 120.00

Page 94: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

62.00 248.00

66.00 132.00

70.00 140.00

68.00 136.00

74.00 1,184.00

87.00 1,044.00

89.00 356.00

96.00 768.00

93.00 1,116.00

95.00 570.00

96.00 576.00

22.00 132.00

Page 95: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

8,974.00

8,974.00

133.00 1,330.00

160.00 3,840.00

723.00 1,446.00

59.00 118.00

61.00 122.00

61.00 122.00

69.00 138.00

72.00 288.00

Page 96: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

80.00 160.00

80.00 160.00

83.00 166.00

83.00 166.00

86.00 344.00

89.00 178.00

104.00 416.00

112.00 224.00

9,218.00

9,218.00

43.00 86.00

45.00 90.00

45.00 90.00

50.00 100.00

57.00 228.00

57.00 114.00

64.00 128.00

65.00 130.00

65.00 130.00

68.00 272.00

Page 97: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

70.00 140.00

77.00 308.00

86.00 172.00

83.00 830.00

42.00 1,008.00

44.00 440.00

23608.00 23,608.00

27,874.00

27,874.00

Page 98: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2277.00 2,277.00

2680.00 2,680.00

2277.00 2,277.00

2680.00 2,680.00

2277.00 2,277.00

2680.00 2,680.00

2277.00 2,277.00

2680.00 2,680.00

2680.00 5,360.00

2277.00 4,554.00

2277.00 4,554.00

2277.00 4,554.00

2680.00 5,360.00

2277.00 4,554.00

2277.00 4,554.00

2277.00 4,554.00

2971.00 2,971.00

2277.00 2,277.00

2277.00 2,277.00

Page 99: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2277.00 2,277.00

2971.00 2,971.00

2277.00 2,277.00

2277.00 2,277.00

2277.00 2,277.00

77,476.00

77,476.00

5971.00 5,971.00

2822.00 2,822.00

1636.00 1,636.00

Page 100: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

15.00 60.00

31.00 31.00

10,520.00

189,913.00

Page 101: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

7026.00 7,026.00

9106.00 9,106.00

28.00 28.00

487.00 487.00

1840.00 1,840.00

2056.00 2,056.00

217.00 217.00

3679.00 3,679.00

95.00 95.00

55.00 55.00

Page 102: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

24,589.00

24,589.00

5899.00 5,899.00

3464.00 3,464.00

3539.00 3,539.00

13.00 13.00

203.00 203.00

755.00 755.00

844.00 844.00

Page 103: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

84.00 84.00

14,801.00

14,801.00

1092.00 1,092.00

47.00 47.00

10.00 10.00

Page 104: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

12352.00 12,352.00

19972.00 19,972.00

10.00 690.00

Page 105: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

34,163.00

34,163.00

12.00 312.00

9.00 396.00

19.00 1,653.00

58.00 580.00

92.00 1,840.00

9.00 126.00

19.00 627.00

19.00 494.00

9.00 90.00

9.00 234.00

19.00 456.00

19.00 190.00

Page 106: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

6,998.00

6,998.00

193.00 3,088.00

110.00 7,480.00

110.00 3,520.00

110.00 2,200.00

254.00 16,256.00

659.00 10,544.00

Page 107: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

222.00 444.00

102.00 2,448.00

248.00 2,480.00

222.00 3,552.00

175.00 1,750.00

129.00 645.00

54,407.00

54,407.00

Page 108: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

9371.00 9,371.00

44.00 3,432.00

44.00 1,100.00

Page 109: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

13,903.00

148,861.00

47.00 1,222.00

34.00 544.00

34.00 340.00

34.00 884.00

1255.00 12,550.00

22.00 220.00

4499.00 4,499.00

9.00 8,730.00

Page 110: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

8.00 1,200.00

1626.00 1,626.00

693.00 6,930.00

9.00 1,890.00

40,635.00

40,635.00

1084.00 1,084.00

Page 111: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

10.00 550.00

68.00 1,156.00

85.00 1,190.00

62.00 868.00

68.00 952.00

142.00 1,988.00

76.00 380.00

68.00 340.00

3047.00 3,047.00

10.00 4,000.00

10.00 1,300.00

8.00 1,720.00

2914.00 29,140.00

Page 112: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

47,715.00

88,350.00

2.00 784.00

3.00 1,176.00

8.00 3,704.00

10.00 210.00

12.00 2,436.00

3.00 1,914.00

4.00 1,356.00

Page 113: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

11,580.00

11,580.00

1.00 638.00

1.00 676.00

Page 114: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836
Page 115: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1,314.00

12,894.00

662,973.00

30,534.00

20,113.00

125,068.00

41,407.00

384,392.00

212,147.00

14,846.00

4,650.00

0.00

47,027.00

15,088.00

139,876.00

189,913.00

148,861.00

88,350.00

12,894.00

2,138,139.00

98,354,394.00

Page 116: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

98,354,394.00

Page 117: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Item Nr. Description Unit Qty

03 00 00 - CONCRETE

03 11 13 Structural Cast-in-Place Concrete Forming

1 Plain concrete 20MPa for blinding thickness 100mm for footing and 50mm under slab on grade m3 36

03 31 00 Structural Concrete

2 Reinforced concrete 35Mpa for strip footing m3 103

3 Reinforced concrete for sub structure for elevator pit m3 4

4 Reinforce concrete 35MPa for slab on grade with 7Ø8 / Liner meter thickness 150mm m3 64

4 Precost for super structure item 1

Concrete Topping

5 Structural screed will wiremesh 50mm thick for floor above hollow core slab m2 1303

6 Sand cement foam concrete on roof avarage 75mm thick m2 363

7 Concrete Pads m2 8

8 Sand cement screed for floors to receive finishing 50mm thick m2 940

03 30 53 - Miscellaneous Cast-in-situ Concrete

9 300mm wide x 200mm thick reinforced concrete 35 Mpa for lintel m 30

10 100mm wide x 200mm thick reinforced concrete 35 Mpa for lintel m 90

11 200mm wide x 200mm thick reinforced concrete 35 Mpa for lintel m 24

Page 118: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for CONCRETE

CARRIED TO SUMMARY

04 00 00 - Masonry

04 22 00 - Concrete Unit Masonry

Internal walls and Partitions

1 200mm thick CMU wall , 2 hour fire rated, m2 33

2 200mm thick CMU wall , 1 hour fire rated, m2 145

3 100mm thick CMU wall 2hr fire rated m2 133

4 100mm thick CMU wall non fire rated m2 542

5 200mm thick 300mm high parapet CMU parapet wall at ground floor, non fire rated m2 17

Page 119: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836
Page 120: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for MASONRY

CARRIED TO SUMMARY

05 00 00 METALS

All metalworks herein shall be completed in full compliance with the Drawings A0-A401,

A0-A402, A0-A403 and Specification.

05 70 00 Decorative Metal

1 Supply and fix 50mm diameter stainless steel hand rails including but not limited to m 26

12mm diameter stainless steel balustrade, 40mm square stainless steel post with 50mm

x 120mm base plate, for staircase, floor mounted, kind, quality, fittings, fixtures,

accessories as shown on Drawing nr A0-A402 and as per Specification.

2 Supply and fix 50mm diameter stainless steel hand rails for staircase, wall mounted, m 22

kind, quality, fittings, fixtures, accessories as shown on Drawing nr A0-A402 and as per

Specification.

3 Supply and fix aluminum powder coated hand rails for balconies, floor mounted, kind, m 53

quality, fittings, fixtures, accessories as shown on Drawings nr A2-A502 and as per

Specification.

4 Supply and fix anti slip nosing strip for staircase, kind, quality, fittings, accessories as m 115

shown on Drawing nr A0-A402 and as per Specification.

05 00 00 Metals

Additional Items

5 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

As per Question and Answer No (65)

5.1 Galvanized steel ladder @ elevator pit as shown in dwg No. (A2-A701) nr 1

Page 121: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for METALS

CARRIED TO SUMMARY

06 00 00 WOOD, PLASTICS, AND COMPOSITES

06 41 00 Architectural Wood Casework

As per Question and Answer No. (89) the kitchen cabinet changed to Aluminum

1 Supply and fix kitchen under counter cabinets (1450mm + 450mm) long 600mm wide nr 4

(counter tops measured separately) at kitchen with wall cabinet MDF melamine

laminated with aluminum edge, base cabinets with polished chrome cabinet pull

handles and all other accessories as per the Drawing nr A0-A902, A0-A903 and

Specification.

2 Supply and fix kitchen under counter cabinets 625 long 600mm wide (counter tops nr 4

measured separately) at kitchen with wall cabinet MDF melamine laminated with

aluminum edge, base cabinets with polished chrome cabinet pull handles and all other

accessories as per the Drawing nr A0-A902, A0-A903 and Specification.

3 Supply and fix kitchen under counter cabinets (1300mm + 875mm) long 600mm wide nr 4

(counter tops measured separately) at kitchen with wall cabinet MDF melamine

laminated with aluminum edge, base cabinets with polished chrome cabinet pull

handles and all other accessories as per the Drawing nr A0-A902, A0-A903 and

Specification.

4 Supply and fix kitchen under counter cabinets 800mm long 600mm wide (counter tops nr 8

measured separately) at kitchen with wall cabinet MDF melamine laminated with

aluminum edge, base cabinets with polished chrome cabinet pull handles and all other

Page 122: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

accessories as per the Drawing nr A0-A902, A0-A903 and Specification.

5 Supply and fix kitchen under counter cabinets (1350mm + 900mm) long 600mm wide nr 4

(counter tops measured separately) at kitchen with wall cabinet MDF melamine

laminated with aluminum edge, base cabinets with polished chrome cabinet pull

handles and all other accessories as per the Drawing nr A0-A902, A0-A903 and

Specification.

6 Supply and fix kitchen under counter cabinets 1200mm long 400mm wide (counter tops nr 4

measured separately) at kitchen with wall cabinet MDF melamine laminated with

aluminum edge, base cabinets with polished chrome cabinet pull handles and all other

accessories as per the Drawing nr A0-A902, A0-A903 and Specification.

Wood, Plastics, and Composites (Cont'd)

1 Supply and fix kitchen under counter cabinets 1450mm long 400mm wide (counter tops nr 4

Page 123: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

measured separately) at kitchen with wall cabinet MDF melamine laminated with

aluminum edge, base cabinets with polished chrome cabinet pull handles and all other

accessories as per the Drawing nr A0-A902, A0-A903 and Specification.

2 Supply and fix kitchen overhead counter cabinets 2700mm long 275mm wide (counter nr 4

tops measured separately) at kitchen with wall cabinet MDF melamine laminated with

aluminum edge, overhead cabinets with polished chrome cabinet pull handles and all

other accessories as per the Drawing nr A0-A902, A0-A903 and Specification.

3 Supply and fix kitchen overhead counter cabinets 3300mm long 275mm wide (counter nr 8

tops measured separately) at kitchen with wall cabinet MDF melamine laminated with

aluminum edge, overhead cabinets with polished chrome cabinet pull handles and all

other accessories as per the Drawing nr A0-A902, A0-A903 and Specification.

06 61 16 Solid Surfacing Fabrications

4 Supply and fix solid acrylic counter top shaped 1100 long 575mm wide with opening for nr 12

wash basin as shown in the Drawing nr A0-A902, A0-A903 and Specification.

5 Supply and fix solid acrylic counter top shaped 600 long 400mm wide with opening for nr 8

wash basin as shown in the Drawing nr A0-A902, A0-A903 and Specification.

6 Supply and fix solid acrylic counter top shaped 900 long 550mm wide with opening for nr 1

wash basin as shown in the Drawing nr A0-A902, A0-A903 and Specification.

7 Supply and fix Solid Acrylic counter top shaped (1450mm+1675mm) long 600mm depth nr 4

with opening for double bowl kitchen sink including 100mm up stand for counter top as

shown in the Drawing nr A0-A904 and Specification.

8 Supply and fix Solid Acrylic counter top shaped (1300mm+2275mm) long 600mm depth nr 4

with opening for double bowl kitchen sink including 100mm up stand for counter top as

shown in the Drawing nr A0-A904 and Specification.

Page 124: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Wood, Plastics, and Composites (Cont'd)

1 Supply and fix Solid Acrylic counter top shaped (1350mm+2300mm) long 600mm depth nr 4

with opening for double bowl kitchen sink including 100mm up stand for counter top as

shown in the Drawing nr A0-A904 and Specification.

2 Supply and fix Solid Acrylic counter top 1200mm long 600mm depth for counter top as nr 8

shown in the Drawing nr A0-A904 and Specification.

3 Supply and fix Solid Acrylic counter top 1200mm long 600mm depth for counter top as nr 4

shown in the Drawing nr A0-A904 and Specification.

06 00 00 Wood, Plastics, and Composites

Additional Items

4 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

As per Question and Answer No. 353

4.1 MDF Laminated Shelf ; Size 3400mm length x 500mm high nr 4

Page 125: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for WOOD, PLASTICS, AND COMPOSITES

CARRIED TO SUMMARY

07 00 00 THERMAL AND MOISTURE PROTECTION

1 Waterproofing works for substructure with vapour barrier 250 microns, horizontal m2 372

2 Two coats of bitumen paint for sub structure including elevator pit walls for vertical surface. m2 228

3 Ditto for horizontal surface m2 166

Page 126: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Wet Area Waterproofing

4 Waterproofing works for wet area, vertical surface, m2 340

5 Ditto for , horizontal surface, m2 170

Roof Waterproofing

6 m2 380

7 Geotextile layer for roof and balcony water proofing works, horizontal surface m2 380

as per the Drawings and Specification.

8 100mm thick insulation for water proofing works at roof and balcony water proofing m2 380

works, horizontal surface, as per the Drawings and Specification.

Roof Hatches

9 Roof hatches nr 1

10 Smoke vent nr 1

11 Anti-vibration insulation m2 52

Waterproofing membrane for roof and balcony, horizontal surface,as per the Drawings and Specification

Page 127: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for THERMAL AND MOISTURE PROTECTION

CARRIED TO SUMMARY

08 00 00 OPENINGS

All works herein shall be completed in full compliance with the Doors & Windows Note

Schedule Drawings A0-A801, A0-A802, A0-A803 and Specification.

Note: Notwithstanding the Provisions of the Standard Method of Measurement, door

sets including doors, frames, vision panels, decoration and ironmongery have been

measured as a composite item and the Contractor should make due reference to the

drawings and specification. No claim for lack or want of knowledge will be entertained

08 13 00 Aluminum Doors

1 Supply and fix aluminum door with fixed double glazed panel, 1600mm wide x 2700mm nr 1

high with 6mm low glass +16+6mm clear glass vision panel including frame, type D4,

finished with and including paint, all accessories and hardware including but not limited

to hinges HDH type, outside and inside door lock, lever handles and latch, wall stop,

roses, weather stripping and escutcheons as stated on the drawings and in in the

Specification.

08 14 00 - Wood Doors

As per Q&A No. 380

2 Supply and fix wooden flush teak veneer door, 54mm thick, 1000mm wide x nr 12

2200mm high including frame, type D1,30 minutes fire rated, finished with and including

paint, all accessories and hardware including but not limited to hinges BBS type, outside

door lock, lever handles and latch, wall stop, roses and escutcheons as stated on the

drawings and in the Specification.

3 Supply and fix wooden flush teak veneer door, 44mm thick, 900mm wide x nr 20

2200mm high including frame, type D2, finished with and including paint, all accessories

and hardware including but not limited to hinges BBS type, outside door lock, lever

handles and latch, wall stop, roses and escutcheons as stated on the drawings and in the

Specification.

4 Supply and fix wooden flush door, 44mm thick, 800mm wide x 2200mm high including nr 24

frame, type D3, finished with and including paint, all accessories and hardware including

but not limited to hinges BBS type, outside door lock, lever handles and latch, wall stop,

Page 128: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

roses and escutcheons as stated on the drawings in the Specification.

OPENINGS(Cont'd)

1 Supply and fix wooden flush teak veneer door, 54mm thick, 1000mm wide x nr 4

2200mm high with 6mm low glass +16+6mm clear glass vision panel 200mm x 900mm

including frame, type D5,30 minutes fire rated, finished with and including paint, all

accessories and hardware including but not limited to hinges BBS type, outside door

lock, lever handles and latch, wall stop, roses and escutcheons as stated on the drawings

and in the Specification.

2 Supply and fix wooden flush teak veneer door, 54mm thick, 1000mm wide x nr 4

2200mm high including frame, type D6,30 minutes fire rated, finished with and including

paint, all accessories and hardware including but not limited to hinges BBS type, outside

door lock, lever handles and latch, wall stop, roses and escutcheons as stated on the

drawings and in the Specification.

Page 129: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3 Supply and fix wooden flush teak veneer door, 54mm thick, 1000mm wide x nr 1

2200mm high with 6mm low glass +16+6mm clear glass vision panel 200mm x 900mm

including frame, type D7,30 minutes fire rated, finished with and including paint, all

accessories and hardware including but not limited to hinges BBS type, outside door

lock, lever handles and latch, wall stop, roses and escutcheons as stated on the drawings

and in the Specification.

08 51 13 Aluminum Windows

4 Supply and fix aluminum double glazed window, 4300mm wide x 1925mm high, nr 2

glass panel with open glass door window including frame, 2150mm wide x 1925mm high

aluminum shutters in front of sliding glass panel, type W1, finished, all accessories and

hardware including but not limited to hinges, handle, lock, weather tight strip etc. as

stated in the Drawings and Specification.

5 Supply and fix aluminum double glazed window, 4150mm wide x 1925mm high, nr 2

glass panel with open glass door window including frame, 2075mm wide x 1925mm high

aluminum shutters in front of sliding glass panel, type W2, finished, all accessories and

hardware including but not limited to hinges, handle, lock, weather tight strip etc. as

stated in the Drawings and Specification.

Page 130: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

OPENINGS(Cont'd)

1 Supply and fix aluminum double glazed window, 4300mm wide x 3000mm high, nr 6

glass panel with open glass door window including frame, 2150mm wide x 3000mm high

aluminum fixed shutters in front of sliding glass panel only, type W3, finished, all accessories and

hardware including but not limited to hinges, handle, lock, weather tight strip etc. as

stated in the Drawings and Specification.

(No glass balustrade is provided, refer to DWG. No. A0-802,A0-803 and A0-901)

2 Supply and fix aluminum double glazed window, 4300mm wide x 3000mm high, nr 8

glass panel with open glass door window including frame, type, W3a, finished, all

accessories and hardware including but not limited to hinges, handle, lock, weather tight

strip etc. as stated in the Drawings and Specification.

3 Supply and fix aluminum double glazed window, 4150mm wide x 3000mm high, nr 6

glass panel with open glass door window including frame, 2075mm wide x 3000mm high

aluminum fixed shutters in front of sliding glass panel only, type W4, finished, all accessories and

hardware including but not limited to hinges, handle, lock, weather tight strip etc. as

stated in the Drawings and Specification.

(No glass balustrade is provided, refer to DWG. No. A0-802,A0-803 and A0-901)

4 Supply and fix aluminum double glazed window, 4150mm wide x 3000mm high, nr 8

glass panel with open glass door window including frame, type W4a, finished, all

accessories and hardware including but not limited to hinges, handle, lock, weather tight

strip etc. as stated in the Drawings and Specification.

5 Supply and fix aluminum double glazed window, 2550mm wide x 3000mm high, nr 2

glass panel with open glass door window including frame, 2550mm wide x 3000mm high

aluminum shutters in front of sliding glass panel type W12, finished, all accessories and

hardware including but not limited to hinges, handle, lock, weather tight strip etc. as

stated in the Drawings and Specification.

6 Supply and fix aluminum double glazed window, 2550mm wide x 2500mm high, nr 1

glass panel with open glass door window including frame, 2550mm wide x 2500mm high

aluminum shutters in front of sliding glass panel, type W13, finished, all accessories and

hardware including but not limited to hinges, handle, lock, weather tight strip etc. as

stated in the Drawings and Specification.

Page 131: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

OPENINGS(Cont'd)

1 Supply and fix aluminum double glazed window, 650mm wide x 1925mm high, nr 28

glass panel with open glass door window including frame, fixed louvers 650mm wide x

550mm high, type W20, finished, all accessories and hardware including but not limited

to hinges, handle, lock, weather tight strip etc. as stated in the Drawings and

Specification.

08 83 00 Mirrors

2 Supply and fix fixed mirror 1100mm width x 1025mm high for bathrooms (size, kind, nr 12

quality, surface treatment, method of jointing, etc. as per the Drawings nr A0-A902, A0-

A903 and Specification).

3 Supply and fix fixed mirror 700mm width x 1025mm high for bathrooms (size, kind, nr 8

quality, surface treatment, method of jointing, etc. as per the Drawings nr A0-A902, A0-

A903 and Specification).

4 Supply and fix fixed mirror 900mm width x 1025mm high for bathrooms (size, kind, nr 4

quality, surface treatment, method of jointing, etc. as per the Drawings nr A0-A902, A0-

Page 132: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

A903 and Specification).

Page 133: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

OPENINGS(Cont'd)

08 00 00 Openings

Additional Items

1 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Page 134: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for OPENINGS

CARRIED TO SUMMARY

09 00 00 - FINISHES

09 23 00 Gypsum Board wall

1 Gypsum wall above wooden cabinet closet m2 45

09 24 00 Cement Plastering

2 15mm thick internal Plastering for block walls to receive paint m2 1116

3 Ditto - for walls to receive tiling at wet areas, m2 168

Page 135: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

FINISHES (Cont'd)

09 30 13 Ceramic Tiling

Floor Tiling

1 Porcelain tile flooring (type - FT1), size 600mm x 600mm, m2 1170

Page 136: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2 Terrazzo tiles, size 400x400mm at roof m2 304

Wall tiling

3 Mosaic tile (type WT4) 100mm x 300mm size for kitchen walls, m2 196

4 White body wall tile (type WT1) 325mm x 977mm size for toilets and bathroom walls, m2 415

Skirting

5 MDF skirting 100mm height, m 580

6 Porcelain Skirting 100mm high for staircase m 60

7 Ditto for balcony m 20

Stair Finish

8 Porcelain tile tread (type - FT1), 230mm wide x 1350mm length, m 99

9 Porcelain tile for riser (type - FT1), 160mm high x 1350mm length, m 115

Threshold

10 Porcelain tile threshold (type - FT1), 200mm wide x 800mm length, m 24

Page 137: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

FINISHES (Cont'd)

09 50 00 Ceilings

1 Supply and install gypsum ceiling, depth of suspension 500 - 1000 mm m2 204

as per the Drawings nr A2-A906,A0-A821

2 Supply and install Moisture resistant gypsum board ceiling at kitchen m2 71

3 Supply and install Moisture resistant gypsum ceiling for toilets laundary and bathrooms m2 101

09 75 13 Stone Wall Facing

4 Stone slab 400mm wide for parapet walls at ground floor, m 18

09 91 00 - Painting

Wall -Painting

5 Painting for walls, m2 1750

6 Painting for walls in staircases, m2 280

Ceiling -Painting

7 Painting for ceiling m2 680

8 Painting for stair case ceiling m2 69

Page 138: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

9 Painting for gypsum board ceiling m2 376

Total for FINISHES

CARRIED TO SUMMARY

10 00 00 SPECIALTIES

10 28 00 –Toilet, Bath and Laundry Accessories

Supply & install Plumbing Fixtures as shown in Drawing nr A0-A902, A0-A903 and

Technical Specification including all accessories, fittings , flexible connections etc.

1 Paper towel dispenser (PTD) nr 24

2 Soap dispenser (SD) nr 24

Page 139: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3 Towel ring nr 24

4 Robe hook nr 24

5 Towel bar nr 24

10 44 13.13 Portable Fire Extinguishers

All items hereunder to be described with kind, quality, size, method of fixing , etc. as per

the Drawings and Specification).

6 Supply & install Portable Fire Extinguishers nr 12

7 Supply & install fire blanket nr 12

10 57 00 Wardrobe and Closet Specialties

8 Supply and fix closets 2850 mm length, 600mm depth, 2400mm high, type BIC01, with nr 12

MDF laminated dark wood veneer shelves, door with MDF white matt lacquer finish and

chromed stainless steel handles, and all other accessories as per the Drawing nr A0-A932

and Specification.

9 Supply and fix closets 1250 mm length, 600mm depth, 2400mm high, type BIC02, with nr 8

MDF laminated dark wood veneer shelves, door with MDF white matt lacquer finish and

chromed stainless steel handles, and all other accessories as per the Drawing nr A0-A932

and Specification.

Page 140: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

SPECIALTIES (Cont'd)

1 Supply and fix closets 2500 mm length, 600mm depth, 2400mm high, type BIC03, with nr 4

MDF laminated dark wood veneer shelves, door with MDF white matt lacquer finish and

chromed stainless steel handles, and all other accessories as per the Drawing nr A0-A932

and Specification.

10 22 23 Portable Partitions, Screens, and Panels

2 Supply and fix shower screen 8mm thick tempered glass 1300mm x 2000mm high nr 4

partition with 700mm x 2000mm flush door, finished, all accessories and hardware

including but not limited to hinges, handle, etc. as stated in the Drawing nr A0-A904 and

Specification.

3 Supply and fix shower screen 8mm thick tempered glass 1150mm x 2000mm high nr 4

partition with 700mm x 2000mm sliding door, finished, all accessories and hardware

including but not limited to hinges, handle, etc. as stated in the Drawing nr A0-A904 and

Specification.

4 Supply and fix shower screen 8mm thick tempered glass 1020mm x 2000mm high nr 8

partition, finished, all accessories and hardware including but not limited to hinges,

handle, etc. as stated in the Drawing nr A0-A904 and Specification.

and Specification.

Page 141: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

SPECIALTIES (Cont'd)

10 00 00 Specialties

Additional Items

1 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

1.01 Towel Pin nr 16

Page 142: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836
Page 143: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for SPECIALTIES

CARRIED TO SUMMARY

11 00 00 EQUIPMENT

All items hereunder to be described with information such as appropriate to the

procurement , design, supply, execution, type, kind, quality, size, method of fixing ,

specified codes of practice, etc. as per the Drawings and Specification).

11 30 00 Residential Equipment

1 Refrigerator/freezer nr 12

2 Exhaust hoods nr 12

3 Cooker nr 12

4 Washing Machine nr 12

11 00 00 Equipment

Additional Items

5 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Page 144: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for EQUIPMENT

CARRIED TO SUMMARY

12 00 00 FURNISHING

All items hereunder to be described with information such as appropriate to the

procurement , design, supply, execution, type, kind, quality, size, method of fixing ,

specified codes of practice, etc. as per the Drawings and Specification).

12 00 00 Furnishing

Additional Items

1 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Page 145: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for FURNISHING

CARRIED TO SUMMARY

14 00 00 - CONVEYING EQUIPMENT

Page 146: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

14 10 10 - PASSENGER ELEVATORS

Contractor Designed Elevators

Supply and install 6 person passenger machine room less lift to serve four floors; refer

Specification for performance capacity, weight load, speed of travel, call system etc.; car

to include floor finish to be as per entrance hallway, mirrored and hardwood ceiling with

recessed and emergency lighting, mirrored and hardwood wall finish, chromium plated

handrails, floor indicator, floor push buttons (including braille floor indicators),

emergency call button/alarm, emergency intercom; each floor to have call button and

floor indicator all as manufacturers recommendations

1 Elevator nr 1

Page 147: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for CONVEYING EQUIPMENT

CARRIED TO SUMMARY

21 00 00 FIRE SUPPRESSION

All Fire suppression works herein shall be completed full incompliance with the Drawings

nr A2-M011, A2-M012, A2-F201, A2-F202, A2-F203, A2-F204 and Specification.

21 12 00 Fire Suppression Standpipes

Supply & Installation testing and commissioning of steel pipes (painted). All fire fighting

pipes to be completed including but not limited to accessories, fittings, couplings

according to NFPA code/ local civil defense code. Including all kind of supports and

hangers all in accordance to the specificaFons and drawings.

1 Ditto, 65 mm diameter m 27

21 11 19 Fire-Department Connection

2 Fire Connection Department including Non- return Valve, 65mm dia. nr 1

21 12 13 Fire-Suppression Hoses and Nozzles

Fire hose reel cabinet C/W 2-1/2" pressure restricted type landing valve 2-1/2" synthetic

hose, 1" automatic swinging hose reel, and multipurpose dry powder extinguisher. The

rate also shall be include all set of valves (landing , gate , angle, PRV……,etc.) , Pressure

gauges.

3 Fire Hose Cabinet. nr 4

21 12 23 Fire-Suppression Hose Valves

Page 148: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Supply and installation valves complete and all necessary accessories, all in accordance

with the specifications and drawings.

4 Gate Valve , 65mm diameter nr 1

Automatic Air Vent

Supply and Installation of automatic air vent, all in accordance with the specifications

and drawings.

5 65 mm diameter. nr 1

FIRE SUPPRESSION (Cont'd)

GENERAL

TESTING, ADJUSTING, AND BALANCING OF MEP SYSTEMS

1 Allow for Starting up, pressure testing, complete testing and commissioning for all Fire Item 1

Page 149: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

fighting system, including all necessary preparations and attendance for authority

approvals.

2 Allow for drawing, manuals, approvals & instruction books. Item 1

3 Allow for protective and decorative painting Item 1

4 Allow for liaison and coordination with local authorities. Item 1

5 The contractor to list here and price any items shown in the drawings, mentioned in the

specifications or required for the satisfactory completion of this section as per the

relevant authority regulations, but not mentioned here. Any such item not listed is

deemed to be included.

21 00 00 Fire Suppression

Additional Items

6 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Page 150: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for FIRE SUPPRESSION

CARRIED TO SUMMARY

22 00 00 - PLUMBING

All items hereunder to be described specified code of practice and regulations, kind,

quality, size, method of fixing , finishes or surface treatments, etc. as per the Drawings

and Specification).

22 05 23 General-Duty Valves for Plumbing Piping

Valves

Valves are classified according to type . Material and/or size . Rates include furnishing

and installing of valves, testing at manufacturer's premises and on site; diameters of

valves and water meter according to pipe diameter which will be connected with it; as

per Drawings and Specification.

Gate Valve

1 20 mm diam. nr 8

2 25 mm diam. nr 48

3 32 mm diam. nr 10

4 40 mm diam. nr 16

5 75 mm diam. nr 2

6 90 mm diam. nr 4

Angle Valve

7 20 mm diam. nr 76

8 25 mm diam. nr 24

Page 151: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Check Valve

9 20 mm diam. nr 8

Globe Valve

10 20 mm diam. nr 4

11 25 mm diam. nr 24

12 40 mm diam. nr 2

Non-Return Valve

13 32 mm diam. nr 4

14 40 mm diam. nr 8

15 63 mm diam. nr 2

Pressure Reducing Valve

16 90 mm diam. nr 1

PLUMBING (Cont'd)

22 11 16 Domestic Water Piping

Domestic water piping is classified by material and diameter. Rates include furnishing

and installing of pipes, fittings, accessories, fixing supports, joints, sleeves, special parts,

connections, hanger supports. Rates to include all works and materials necessary for

complete installation for piping system as per the Drawings and Specification.

Water Supply System

1-Cold Water Supply

1 90 mm diameter. m 30

Page 152: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2 75 mm diameter. m 23

3 63 mm diameter. m 12

4 40 mm diameter. m 22

5 32 mm diameter. m 10

6 25 mm diameter. m 430

7 20 mm diameter. m 275

2-Hot Water Supply

8 20 mm diameter. m 220

3 - Accessories

9 Hose Bibb 20mm . nr 2

10 Water Meter 40 mm. nr 8

11 Water Meter 32 mm. nr 4

12 Water Hammer Arrestor nr 28

13 Automatic Air Vent. nr 28

14 Pressure Gauge . nr 2

15 Strainer 90 mm. nr 1

22 13 16 Sanitary Waste and Vent Piping

Sanitary Pipe Works

Sanitary pipe works is classified by material and diameter. Rates include furnishing and

installing of pipes, fittings, accessories, fixing support, joints, sleeves , special parts,

connections, hanger supports. Rates for pipework below ground also include

excavation, backfilling , civil work, trenches and any other accessories or fittings

necessary for complete installation of the piping system. Testing of pipes at the

manufacturer's premises is included. All as per the Drawings and Specification.

Page 153: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

PLUMBING (Cont'd)

Pipes and fitting above ground

Waste Pipe

1 50 mm diameter. m 31

2 75 mm diameter. m 30

3 110 mm diameter. m 164

Soil Pipe

4 110 mm diameter. m 85

Pipes and fitting below ground

Waste pipe

5 75 mm diameter. m 5

6 110 mm diameter. m 56

Soil Pipe

7 110 mm diameter. m 107

Vent Pipe Works

Vent pipes are classified by material and diameter. Rates include furnishing and installing

of pipes, fittings, accessories, fixing support, joints, sleeves, special parts, connections,

hanger supports. Rates include furnishing and installing of pipes, fittings, accessories,

fixing support, joints, sleeves , special parts, connections, hanger supports. Rates for

pipework below ground also include excavation, backfilling , civil work, trenches and any

other accessories or fittings necessary for complete installation of the piping system.

Testing of pipes at the manufacturer's premises is included. All as per the Drawings and

Specification.

Pipes and fittings above ground

Page 154: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

8 75 mm diameter. m 146

Pipes and fitting below ground

9 75 mm diameter. m 10

22 13 19.13 Sanitary Drains

Sanitary drains (to include rainwater pipework and condensate drain pipework) are

classified by material and diameter. Rates include furnishing and installing of pipes,

fittings, accessories, fixing supports, joints, sleeves, special parts, connections, hanger

supports. Rates also include testing of pipes at the manufacturer's premises. All as per

the Drawings and specification.

PLUMBING (Cont'd)

Rain water Pipe

1 75 mm diameter. m 150

Condensate Drain Pipe Works

2 20 mm diameter. m 145

3 25 mm diameter. m 13

22 33 00 Electric Domestic Water Heaters

Electric domestic water heaters are classified according to capacity. Rates include

furnishing of heater complete with safety valves, air vent, pressure and temperature

relief gauges, drain valves, all valves set (angle, gate, non return, etc. .), thermostat,

heating element, contactors, switch, support, bolts, nuts, connection of pipes, testing on

site, commissioning and putting into service.

Page 155: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

4 EWH-A2-01 with (30 litres / 1200 W) capacity. nr 20

5 EWH-A2-02 with (100 litres / 1500 W) capacity. nr 16

22 40 00 Plumbing Fixtures

All items described hereunder to be of kind, quality, size, nature of base, method of

fixing, complete with accessories etc. as per the Drawings nr V1-903 and Specification

6 Floor Drain (FD) nr 36

7 Flexible Shower Hose(Sprayer ,valve , etc.) nr 24

8 Water Closet nr 24

9 Floor clean out nr 4

10 Roof drain nr 9

11 Vent cap nr 6

12 Bath tub (BT) including taps, plug, accessories and fitting. nr 0

13 Wash basin (WB) nr 24

Page 156: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

PLUMBING (Cont'd)

As per question & answer no. 358 clothes washer not in contract, only connector

1 Washing machine connections (washing machine not in contract) nr 12

As per question & answer no. 360 shower channel to be used

2 Shower (SHO) including shower channel, mixer tap, fitting, spray and adjustable bar nr 16

setting

3 Kitchen sink nr 12

4 Taps for wash basin including fittings , plugs, valves, connections and waste. nr 24

5 Mixer tap for kitchen sink including fitting, plugs, chrome plated pipes, valves and nr 12

waste

22 00 00 - Plumbing

Additional Items

6 Inspection chamber as per Drawings and Specification; connected directly to nr 9

sewer network.

7 Clean out (CO) nr 29

8 Roof Water tank as per Specification; rate shall be include supplying and nr 2

installing, all fittings, accessories, valves, pipework, vents etc. as per the Drawings

and Specification

9 Balcony Drain nr 12

10 Gully Trap nr 6

Additional Items

11 Marking the position of holes, mortices and chases in the structure Item 1

12 Identification; plates, discs, labels, tapes, bands, arrows, symbols, letters, numbers and Item 1

charts; as stated on drawings and in Specification

13 Testing and commissioning of entire installation Item 1

14 Preparation of as-built drawings Item 1

Page 157: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

PLUMBING (Cont'd)

1 Preparation of operation and maintenance manuals Item 1

2 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Page 158: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for PLUMBING

CARRIED TO SUMMARY

23 00 00 - HEATING, VENTILATING, AND AIR CONDITIONING (HVAC)

All HVAC works shall be completed as per the Drawings and Specification.

23 07 13 Duct Insulations

Page 159: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

All items hereunder to be described with in type, kind, quality, thickness, method of

fixing , specified codes of practice, etc. as per the Drawings and Specification).

1 Supply and fix ductwork insulations outdoor for (supply, return, fresh air, exhaust, etc.); m2 240

air duct to include fixing and accessories as per the Drawings and Specification

23 23 00 Refrigerant Piping

Supply and fix refrigerant pipes for FCU from condensing units to indoor installed AC

units including fittings, sleeves and all accessories as per the Drawings and Specification

2 20 mm diameter with max liquid line 10 mm. m 445

23 31 00 HVAC Ducts and Casings

All items hereunder to be described with in type, kind, quality, size, method of fixing ,

specified codes of practice, and method of fixing supports, etc. as per the Drawings and

Specification).

Notwithstanding the provisions of the Standard Method of Measurement, internal

ductwork is to include insulation to the ductwork. No claim for additional cost due to

lack or want of knowledge will be entertained

3 Supply and fix insulated indoor galvanized steel sheet metal duct work for all HVAC work Kg 2430

as specified and as indicating on drawings, complete with bends, supports, connections,

fittings, splices and all accessories to complete the work.

Page 160: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

HEATING, VENTILATING, AND AIR CONDITIONING (Cont'd)

23 33 13.13 Volume-Control Dampers

All items hereunder to be described with ,type, kind, quality, size, method of fixing ,

specified codes of practice, etc. as per the Drawings and Specification).

Volume Dampers

1 Volume Damper ; 100x100 mm . nr 20

2 Volume Damper ; 150x100 mm . nr 6

3 Volume Damper ; 150x150 mm nr 2

4 Volume Damper ; 150 mm dia. circular damper. nr 12

5 Volume Damper ; 200x150 mm . nr 4

6 Volume Damper ; 250x200 mm . nr 2

7 Volume Damper ; 300x200 mm . nr 1

8 Volume Damper ; 300x350 mm . nr 5

9 Volume Damper ; 400x300 mm . nr 22

10 Volume Damper ; 400x150 mm . nr 2

11 Volume Damper ; 400x400 mm . nr 4

12 Volume Damper ; 500x400 mm . nr 14

Page 161: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

13 Splitter Dampers

14 Splitter Damper nr 1

23 33 13.16 Fire Dampers

As per Q&A no. 362 the word 'motorized' to be deleted in the description

All items hereunder to be described with information such as type, kind, quality, size,

method of fixing , specified codes of practice, etc. as per the Drawings and Specification).

15 Fire Damper ; Size 100 x 100 mm. nr 8

16 Fire Damper ; Size 100 x 150 mm. nr 12

17 Fire Damper ; Size 150 x 150 mm. nr 4

23 33 46 Flexible Ducts

All items hereunder to be described with in type, kind, quality, size, method of fixing ,

specified codes of practice, placing and method of fixing supports, etc. as per the

Drawings and Specification).

18 Supply and install Flexible duct with insulation ; size diam 150 mm . m 7

HEATING, VENTILATING, AND AIR CONDITIONING (Cont'd)

23 34 00 HVAC Fans

All items hereunder to be described with information such as appropriate to the

procurement , capacity, design, supply, execution, type, kind, quality, size, method of

fixing , specified codes of practice, etc. as per the Drawings and Specification).

Supply and install exhaust fan as specified and as indicated in drawing. Fan consists of

casing, fan, motor, control, filter, screen, sand trap louver, all electrical works

(components, wiring, etc.) and all accessories. Electrical power supply 220/1/60.

Page 162: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Wall Mounted

1 Exhaust Fan (EF-01) 50 Pa with total air flow 25 L/S nr 12

Ceiling Mounted

2 Exhaust Fan (EF-02 ) 100 Pa with total air flow 25 L/S . nr 24

Range Hood Fan

3 Range Hood Fan (RH-01) ;150 Pa with total air flow 50 L/S . nr 12

Garbage Exhaust fan

4 Garbage Exhaust fan (GEF-01/GEF-02) ;150 Pa with total air flow 80 L/S . nr 2

23 37 00 Air outlets and Inlets

All items hereunder to be described with information such as type, kind, quality, size,

method of fixing , specified codes of practice, etc. as per the Drawings and Specification).

Supply and install Painted Supply linear bar air Register with complete accessories.as

per the Drawings and Specification.

5 Size 450x200 mm ; 260 L/s . nr 4

6 Size 500x200 mm ; 280 L/s . nr 2

7 Size 500x200 mm ; 285 L/s . nr 2

8 Size 500x200 mm ; 460 L/s . nr 4

9 Size 600x200 mm ; 470 L/s nr 4

10 Size 650x200 mm ; 265 L/s. nr 2

11 Size 750x200 mm ; 300 L/s. nr 2

12 Size 750x250 mm ; 365 L/s. nr 2

13 Size 800x200 mm ; 315 L/s nr 2

14 Size 850x200 mm ; 345L/s . nr 2

15 Size 850x250mm ; 400L/s . nr 2

16 Size 1050x200 mm ; 440L/s nr 2

Page 163: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

17 Size 1050x250 mm ; 520L/s nr 2

HEATING, VENTILATING, AND AIR CONDITIONING (Cont'd)

Supply and install Painted Return linear bar air grille with complete accessories.as per

the Drawings and Specification.

1 Size 450x200 mm ; 260 L/s nr 4

2 Size 500x200 mm ; 280 L/s . nr 2

3 Size 500x200 mm ; 285 L/s . nr 2

4 Size 500x200 mm ; 460 L/s nr 4

5 Size 600x200 mm ; 470 L/s nr 4

6 Size 650x200 mm ; 265 L/s. nr 2

7 Size 750x200 mm ; 300 L/s. nr 2

8 Size 750x250 mm ; 365 L/s. nr 2

9 Size 800x200 mm ; 315 L/s nr 2

10 Size 850x200 mm ; 345L/s . nr 2

11 Size 850x250mm ; 400L/s . nr 2

12 Size 1050x200 mm ; 440L/s . nr 2

13 Size 1050x250 mm ; 520L/s . nr 2

Supply and install 3 way Supply ceiling diffuser with complete accessories.as per the

Drawings and Specification.

14 Size 150X150 mm ; 40 L/s. nr 12

Supply and install exhaust air louver with complete accessories as per the Drawings

and Specification.

Page 164: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

15 Exhaust air louver (150X100)mm . nr 24

16 Exhaust air louver (200X150)mm . nr 12

23 82 00 Convection Heating and Cooling Units

All items hereunder to be described with information such as appropriate to the

procurement , capacity, design, supply, execution, type, kind, quality, size, method of

fixing , specified codes of practice, etc. as per the Drawings and Specification).

Supply and install fresh air handing unit as specified and as indicated in drawing. Unit

to be complete with air cooled condensing unit, fan, pre-filter, bag filter, damper and

sand trap louver with filter, valves, controls, all electrical works (components, wiring ,

etc.) and all accessories. Electrical power supply 380/3/60

17 (FAHU-A2-01) , 860 L / s , 350 Pa ; Total load 34 KW . nr 1

HEATING, VENTILATING, AND AIR CONDITIONING (Cont'd)

Supply and install concealed fan coil unit as specified and as indicated on drawings.

Unit to be complete with air cooled condensing unit, fan, filter, valves, control,

thermostat, all electrical works (components , wiring , etc. .) and all accessories.

Electrical power supply 220/1/60.

Ground Floor / First Floor

1 FCU-(GF1/FF1-01) , 260 L / s , 75 Pa ; Electrical data power 1.8 KW . nr 2

2 FCU-(GF1/FF1-02) , 472 L / s , 75 Pa ; Electrical data power 3.6 KW . nr 2

3 FCU-(GF2/FF2-01) , 261 L / s , 75 Pa ; Electrical data power 1.8 KW nr 2

4 FCU-(GF2/FF2-02) , 472 L / s , 75 Pa ; Electrical data power 3.6 KW nr 2

5 FCU-(GF3/FF3-01) , 282 L / s , 75 Pa ; Electrical data power 1.8 KW . nr 2

Page 165: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

6 FCU-(GF3/FF3-02) , 462 L / s , 75 Pa ; Electrical data power 3.6 KW . nr 2

7 FCU-(GF4/FF4-01) , 283 L / s , 75 Pa ; Electrical data power 1.8 KW . nr 2

8 FCU-(GF4/FF4-02) , 461 L / s , 75 Pa ; Electrical data power 3.6 KW . nr 2

HEATING, VENTILATING, AND AIR CONDITIONING (Cont'd)

Second Floor

9 (FCU-SF1-01) , 480 L / s , 75 Pa ; Electrical data power 3.6 KW . nr 1

10 (FCU-SF1-01) , 343 L / s , 75 Pa ; Electrical data power 2.7 KW . nr 1

11 (FCU-SF1-02) , 314 L / s , 75 Pa ; Electrical data power 2.7 KW . nr 1

12 (FCU-SF1-03) , 265 L / s , 75 Pa ; Electrical data power 1.8 KW . nr 1

13 (FCU-SF2-01) , 480 L / s , 75 Pa ; Electrical data power 3.6 KW . nr 1

14 (FCU-SF2-01) , 344 L / s , 75 Pa ; Electrical data power 2.7 KW . nr 1

15 (FCU-SF2-02) , 314 L / s , 75 Pa ; Electrical data power 1.8 KW . nr 1

16 (FCU-SF2-03) , 265 L / s , 75 Pa ; Electrical data power 1.8 KW . nr 1

Third Floor

17 (FCU-LF1-01) , 558 L / s , 75 Pa ; Electrical data power 3.6 KW . nr 1

18 (FCU-LF1-01) , 395 L / s , 75 Pa ; Electrical data power 2.7 KW . nr 1

19 (FCU-LF1-02) , 365 L / s , 75 Pa ; Electrical data power 2.7 KW . nr 1

20 (FCU-LF1-03) , 301 L / s , 75 Pa ; Electrical data power 1.8 KW . nr 1

21 (FCU-LF2-01) , 559 L / s , 75 Pa ; Electrical data power 3.6 KW nr 1

22 (FCU-LF2-01) , 396 L / s , 75 Pa ; Electrical data power 2.7 KW . nr 1

23 (FCU-LF2-02) , 366 L / s , 75 Pa ; Electrical data power 2.7 KW nr 1

24 (FCU-LF2-03) , 301 L / s , 75 Pa ; Electrical data power 1.8 KW . nr 1

Page 166: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

HEATING, VENTILATING, AND AIR CONDITIONING (Cont'd)

23 05 93 Testing, Adjusting and Balancing for HVAC

All items hereunder to be described with type of installation, preparatory operations,

stages of test (nr), required attendance, applicable codes etc. as per the Drawings and

Specification).

1 Air balancing of the ducting network Item 1

2 Testing, balancing and commissioning of all the equipment Item 1

Additional Items

3 Marking the position of holes, mortices and chases in the structure Item 1

4 Identification; plates, discs, labels, tapes, bands, arrows, symbols, letters, numbers and Item 1

charts; as stated on drawings and in Specification

5 Testing and commissioning of entire installation Item 1

6 Preparation of as-built drawings Item 1

7 Preparation of operation and maintenance manuals Item 1

8 The Contractor is to list here and price any items shown on the Drawings, mentioned in Item

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

8.01 Exhaust air Grille (100X100)mm . nr 4

8.02 Volume Damper ; 500x500 mm . nr 4

8.03 Fresh air Grille (250X200)mm . nr 1

Page 167: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for HVAC

CARRIED TO SUMMARY

26 00 00 - ELECTRICAL

All works hereunder shall be completed as per the Drawings and Specification.

26 05 19 Low Voltage Electrical Power Conductors and cables

All items hereunder to be of type, kind, number of cores, armoring and sheathings,

method of fixing , specified codes of practice, etc. as per the Drawings and Specification).

Notwithstanding the Provisions of the method of measurement, cables have been

itemised and referenced to the circuit. The contractor is to make due reference to

drawings nrs E000, E001, E002, E003, ELV201, EL201, EP201, LP201, PS301, PS302, E401,

E402 and E403 for full details and is to allow for all cabling, junctions, flexible

connections, feeder units etc. required to complete the installation in accordance with

the drawings and Specification. No claim for want or lack of knowledge will be

entertained

1 Lighting circuits Item 1

2 Power circuits Item 1

3 Fire alarm circuits Item 1

4 Cooker circuits Item 1

Page 168: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

5 Water heater circuits Item 1

6 Fan circuits Item 1

7 Outdoor lighting circuits Item 1

8 HVAC control circuits Item 1

9 Emergency lighting circuits Item 1

10 Lift power circuits Item 1

11 Lightning protection Item 1

ELECTRICAL (Cont'd)

26 05 26 Grounding and Bonding for Electrical Systems

Page 169: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

All items hereunder to be described with information such as type, kind, number of

cores, armoring and sheathings, method of fixing , specified codes of practice, etc. as per

the Drawings and Specification).

1 Grounding system Item 1

26 05 33.13 Conduit for Electrical Systems

All items hereunder to be described with information such as type, kind, , method of

fixing , specified codes of practice, etc. as per the Drawings and Specification).

Notwithstanding the Provisions of the method of measurement, conduits have been

itemised and referenced to the circuit. The contractor is to make due reference to

drawings nrs E000, E001, E002, E003, ELV201, EL201, EP201, LP201, PS301, PS302, E401,

E402 and E403 for full details and is to allow for all cabling, junctions, flexible

connections, feeder units etc. required to complete the installation in accordance with

the drawings and Specification. No claim for want or lack of knowledge will be

entertained

2 Lighting circuits Item 1

3 Power circuits Item 1

4 Fire alarm circuits Item 1

5 Cooker circuits Item 1

6 Water heater circuits Item 1

7 Fan circuits Item 1

8 Outdoor lighting circuits Item 1

9 HVAC control circuits Item 1

10 Emergency lighting circuits Item 1

Page 170: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

ELECTRICAL (Cont'd)

1 Lift power circuits Item 1

2 Lightning protection Item 1

26 05 36 Cable Trays for Electrical Systems

All items hereunder to be of type, kind, method of fixing , specified codes of practice,

etc. as per the Drawings and Specification).

Notwithstanding the Provisions of the method of measurement, cables trays have been

itemised. The contractor is to make due reference to drawings nrs E000, E001, E002,

E003, ELV201, EL201, EP201, LP201, PS301, PS302, E401, E402 and E403 for full details

and is to allow for complete cable trays for electrical systems, junctions, connections,

etc. required to complete the installation in accordance with the drawings and

Specification. No claim for want or lack of knowledge will be entertained

3 Cable trays for electrical system Item 1

4 Cable ladders for electrical system Item 1

26 24 13 Switchboards

5 All items hereunder to be described with information such as type, kind, rated capacity,

method of fixing, cores reference to Specification, fuses, background, specified codes of

practice, etc. as per the Drawings and Specification).

26 24 16 Panel boards

Page 171: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

6 All items hereunder to be described with information such as type, kind, rated capacity,

method of fixing, cores reference to Specification, fuses, codes of practice, etc. as per

the Drawings and Specification).

7 Sub-main distribution boards Item 1

26 27 13 Electricity Metering

8 All items hereunder to be described with information such as type, kind, rated capacity, Item 1

method of fixing, cores reference to Specification, fuses, codes of practice, etc. as per

the Drawings and Specification).

ELECTRICAL (Cont'd)

26 27 26 Wiring Devices

Switches & Push Buttons

All items hereunder to be described with information such as appropriate to the

procurement , type, kind, quality, size, method of fixing , specified codes of practice, etc.

as per the Drawings and Specification).

Page 172: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1 One way two gang switch nr 116

2 Two way one gang switch nr 44

Power Outlets

3 Single outlet nr 56

4 Double outlet nr 106

5 Double outlet; NEMA 5-18R; weather proof grounding type nr 12

6 Single point shaver outlet nr 20

7 Single point kitchen hood outlet nr 20

8 Floor box finished with three 15A, 230V power outlet, for low current and telecom nr

socket refer telecom/low current package.

9 Fusible disconnect switch plate, double poles, 32A, 220V, 60HZ, with lamp Indicator for nr 48

water heater

10 Fusible disconnect switch plate, double poles, 32A, 220V, 60HZ, with lamp Indicator for nr 44

air conditioning

11 Fusible disconnect switch plate, double poles, 32A, 220V, 60HZ, with lamp Indicator for nr 20

refrigerator (NORMAL SOCKET OUTLET AS PER Q&A # 539)

Page 173: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

ELECTRICAL (Cont'd)

1 nr 44

2 Fusible disconnect switch plate, double poles, 30A, 220V, 60HZ for exhaust ceiling fan nr 36

3 Fusible disconnect switch plate, double poles, 30A, 220V, 60HZ for wall mounted nr 20

exhaust fan

26 50 00 Lighting

All items hereunder to be described with information such as appropriate to the

procurement , type, kind, quality, size, method of fixing , specified codes of practice, etc.

as per the Drawings and Specification).

4 Luminaire, ceiling mounted, satin steel/nickel/plastic, white diffuser; type B2 nr 24

5 Luminaries, downlight, compact fluorescent lamp with glass cover, 1 x 26W CFL; type D1 nr 142

6 Luminaries, recess mounted downlight, compact fluorescent lamp with glass cover, 1 x nr 48

26W CFL; type D2

7 Luminaire, ceiling mounted, with semi sphere opal bowl diffuser; 1 x 18W, 220V, 60hz; nr 40

type R2

8 Luminaire, power light, steel/chrome/plastic, white, 1 x 50W; type S2 nr 96

9 Luminaire, ceiling mounted, square shaped, 4 x 50W; type S3 nr 24

10 Luminaire, wall mounted 1 x 26W CFL with glass cover; type W1 nr 8

11 Luminaire, wall mounted fluorescent, steel chrome/plastic, white 2 x 26W; type W2 nr 36

12 Luminaire, up/down wall mounted; 1 x 26W CDL; type W3 nr 14

Fusible disconnect switch plate, double poles, 30A, 220V, 60HZ for TV (NORMAL SOCKET OUTLET AS PER Q&A # 539)

Page 174: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

ELECTRICAL (Cont'd)

1 Luminaire, wall mounted CDL; 1 x 26W with aluminum dome reflector; type W4 nr 24

2 Luminaire, wall mounted satin nickel/plastic, white; 1 x 18W CDL; type W5 nr 20

3 Luminaire, self contained exit light with directional arrow nr 10

26 00 00 - Electrical

Additional Items

4 Marking the position of holes, mortices and chases in the structure Item 1

5 Identification; plates, discs, labels, tapes, bands, arrows, symbols, letters, numbers and Item 1

Page 175: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

charts; as stated on drawings and in Specification

6 Testing and commissioning of entire installation Item 1

7 Preparation of as-built drawings Item 1

8 Preparation of operation and maintenance manuals Item 1

9 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

9.01 Power supply cables from Electric meters to Distribution boards ( as per O&A 537) Item 1

Page 176: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for ELECTRICAL

CARRIED TO SUMMARY

Telecommunication / Low Current

STRUCTURED CABLING SYSTEM

Supply, Install, Test, connect and commission inclusive of all cabling, conduits and

containment, socket outlets, all in accordance with the relevant service provider

regulations , rules, recommendation and requirements and in accordance with the

specifications and drawings.

1 Information Outlet, Flush Type 1 DATA,1 Telephone 0.3 Meters A.F.F.L. nr 28

2 Telephone Outlet, Wail Mounted flush Type, MTD 0.30m A.F.F.L nr 16

3 Telephone Outlet, Wall Mounted, Flush Type 1.2 Metem A.F.F.L. nr 12

4 TV outlet, wall mounted nr 28

5 9U Telecom Cabinet, Wall Mounted nr 12

6 Optical Distribution box nr 1

7 Set Top Box nr 28

8 LED TV nr 28

9 CAT 6A, UTP Cable m 950

10 Single Mode Fiber Optic Cable -1 x 24 Core m 180

Page 177: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Video Entry System / Intercom

Supply, Install, Test, connect and commission inclusive of all cabling, conduits and

containment, socket outlets, all in accordance with the relevant service provider

regulations, rules, recommendation and requirements and in accordance with the

specifications and drawings.

1 Main Entrance Station nr 1

2 Residential Main Station / Intercom Outlet nr 12

3 CAT 6A, UTP Cable m 200

Consumption Metering

Supply, Install, Test, connect and commission inclusive of all cabling, conduits and

containment, socket outlets, all in accordance with the relevant service provider

regulations , rules, recommendation and requirements and in accordance with the

specifications and drawings.

4 Metering Receiver nr 1

Page 178: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

5 M-bus Cable, 2 x 18AWG m 55

Fire Alarm System

Supply, install, connection, testing and commissioning of wiring and equipment for Fire

Alarm System including all necessary materials and accessories to reflect complete

system installation.

6 Addressable, smoke detector nr 16

7 Addressable, smoke detector with sound base nr 17

8 Addressable, heat detector nr 16

9 Addressable, Manual Pull Station nr 16

10 Fire Alarm Rom With Strobe nr 16

11 Fault Isolator nr 5

Fire Alarm System (cont'd)

Page 179: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1 Control Module nr 5

2 Fire Alarm Control Panel nr 1

3 Power Supply Unit, 24v nr 1

4 Loop Cable, 2x1.5mm2 Fire Resistant m 420

5 24V Cable, 2x2.5mm2 fire Resistant m 150

Additional Items

The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

ADDITIONAL (As per Q&A Log 19, 343)

5.1 Single Mode Fiber Optic Cable - 1 x 2 Core m 264

5.2 ACTIVE COMPONENTS (AS PER Q&A 487) nr 12

Page 180: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for COMMUNICATIONS

CARRIED TO SUMMARY

31 00 00 EARTHWORK

All works herein shall be completed in full compliance with the Drawings nr A-5001,A-

5002,A-5003.A-S000.,A-S005,A-S401and Specification.

31 10 00 Site Clearing

1 Site preparation, clearing site vegetation m2 392

31 23 16 Excavation

2 Excavating top soil for preservation, average depth 150mm. m2 392

3 Excavating pits(17 nr), maximum depth ≤ 2.00m. m3 463

4 Excavating trenches for grade beams, width ≤ 0.3m m3 21

31 23 23 .13 Backfill

5 Filling to excavations, average thickness > 0.25 m, arising from excavated materials, all m3 203

fill shall be compacted to 75% relative density for cohesionless soils as per ASTM

D4254/ASTM D4293 or 95% maximum density as determined by ASTM D698 for

cohesive material, as per the Drawings and Specifications

31 23 23.23 Compaction

6 Surface treatments, compacting bottom of excavation, compaction to meet 85% of m2 638

relative density for cohesion-less soils or 95% maximum density as determined by ASTM

Page 181: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

D1557 for cohesive materials perthe Drawings and 5pecifications)

31 23 16.26 Rock Removal

7 Disposal of excavated material, off site as stated in the Specification. m3 339

31 31 16 Termite Control

1 Termite control for the horizontal surface (method and type of treatment as per the m2 638

Drawings and Specifications)

2 Termite control for vertical surface (method and type of treatment as per the Drawings m2 676

and Specifications)

Page 182: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Additional Items

3 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Page 183: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for EARTHWORK

CARRIED TO SUMMARY

03 00 00 Concrete

04 00 00 Masonry

05 00 00 Metal

06 00 00 Wood, Plastics and Composites

07 00 00 Thermal and Moisture Protection

08 00 00 Openings

09 00 00 Finishes

10 00 00 Specialties

11 00 00 Equipment

12 00 00 Furnishing

14 00 00 Conveying Equipment

21 00 00 Fire Suppression

22 00 00 Plumbing

23 00 00 Heating, Ventilating and Air Conditioning (HVAC)

26 00 00 Electrical

27 00 00 Communications

31 00 00 Earthwork

Page 184: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

SUBTOTAL

MULTIPLY BY 6 BLOCKS 6

AMOUNT FOR APARTMENT TYPE A2 TO SUMMARY

Page 185: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Rate Amount

164.00 5,904.00

380.00 39,140.00

656.00 2,624.00

183.00 11,712.00

539919.00 539,919.00

25.00 32,575.00

17.00 6,171.00

310.00 2,480.00

17.00 15,980.00

20.00 600.00

7.00 630.00

13.00 312.00

Page 186: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

658,047.00

658,047.00

39.00 1,287.00

55.00 7,975.00

42.00 5,586.00

34.00 18,428.00

35.00 595.00

Page 187: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

33,871.00

Page 188: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

33,871.00

294.00 7,644.00

113.00 2,486.00

143.00 7,579.00

20.00 2,300.00

283.00 283.00

Page 189: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

20,292.00

1752.00 7,008.00

540.00 2,160.00

2390.00 9,560.00

838.00 6,704.00

Page 190: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2025.00 8,100.00

1020.00 4,080.00

37,612.00

37,612.00

1251.00 5,004.00

Page 191: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

401.00 4,812.00

227.00 1,816.00

341.00 341.00

735.00 2,940.00

865.00 3,460.00

Page 192: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

18,373.00

18,373.00

832.00 3,328.00

282.00 2,256.00

282.00 1,128.00

576.00 2,304.00

Page 193: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

9,016.00

65,001.00

2.00 744.00

5.00 1,140.00

5.00 830.00

Page 194: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

22.00 7,480.00

22.00 3,740.00

37.00 14,060.00

3.00 1,140.00

23.00 8,740.00

514.00 514.00

2966.00 2,966.00

34.00 1,768.00

Page 195: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

43,122.00

43,122.00

43,122.00

2236.00 2,236.00

1460.00 17,520.00

1012.00 20,240.00

1012.00 24,288.00

Page 196: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

64,284.00

64,284.00

2171.00 8,684.00

1692.00 6,768.00

Page 197: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2497.00 2,497.00

6075.00 12,150.00

5905.00 11,810.00

Page 198: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

41,909.00

41,909.00

9410.00 56,460.00

7574.00 60,592.00

9081.00 54,486.00

7310.00 58,480.00

5447.00 10,894.00

4557.00 4,557.00

Page 199: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

245,469.00

245,469.00

827.00 23,156.00

97.00 1,164.00

82.00 656.00

82.00 328.00

Page 200: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

25,304.00

Page 201: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

25,304.00

Page 202: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

376,966.00

55.00 2,475.00

22.00 24,552.00

21.00 3,528.00

Page 203: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

30,555.00

30,555.00

55.00 64,350.00

Page 204: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

32.00 9,728.00

53.00 10,388.00

72.00 29,880.00

17.00 9,860.00

27.00 1,620.00

27.00 540.00

24.00 2,376.00

20.00 2,300.00

40.00 960.00

Page 205: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

132,002.00

132,002.00

54.00 11,016.00

56.00 3,976.00

56.00 5,656.00

102.00 1,836.00

11.00 19,250.00

11.00 3,080.00

11.00 7,480.00

11.00 759.00

Page 206: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

11.00 4,136.00

57,189.00

219,746.00

21.00 504.00

22.00 528.00

Page 207: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

35.00 840.00

17.00 408.00

31.00 744.00

54.00 648.00

76.00 912.00

1993.00 23,916.00

875.00 7,000.00

Page 208: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

35,500.00

35,500.00

1749.00 6,996.00

791.00 3,164.00

816.00 3,264.00

557.00 4,456.00

Page 209: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

17,880.00

17,880.00

17.00 272.00

Page 210: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

272.00

Page 211: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

53,652.00

465.00 5,580.00

Page 212: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

5,580.00

Page 213: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

0.00

Page 214: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

47027.00 47,027.00

Page 215: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

47,027.00

52.00 1,404.00

552.00 552.00

3082.00 12,328.00

Page 216: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

503.00 503.00

96.00 96.00

14,883.00

14,883.00

205.00 205.00

Page 217: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836
Page 218: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

205.00

15,088.00

20.00 160.00

25.00 1,200.00

34.00 340.00

48.00 768.00

191.00 382.00

235.00 940.00

Page 219: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

19.00 152.00

68.00 272.00

72.00 1,728.00

159.00 318.00

40.00 160.00

45.00 360.00

93.00 186.00

1720.00 1,720.00

8,686.00

8,686.00

120.00 3,600.00

Page 220: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

98.00 2,254.00

72.00 864.00

48.00 1,056.00

39.00 390.00

25.00 10,750.00

17.00 4,675.00

16.00 3,520.00

29.00 58.00

1576.00 12,608.00

1237.00 4,948.00

46.00 1,288.00

96.00 2,688.00

46.00 92.00

240.00 240.00

Page 221: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

49,031.00

49,031.00

11.00 341.00

17.00 510.00

29.00 4,756.00

22.00 1,870.00

28.00 140.00

37.00 2,072.00

37.00 3,959.00

Page 222: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

17.00 2,482.00

28.00 280.00

16,410.00

16,410.00

22.00 3,300.00

9.00 1,305.00

10.00 130.00

Page 223: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

275.00 5,500.00

322.00 5,152.00

192.00 6,912.00

38.00 912.00

313.00 7,512.00

202.00 808.00

171.00 1,539.00

43.00 258.00

33,328.00

Page 224: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

33,328.00

41.00 492.00

292.00 4,672.00

166.00 3,984.00

425.00 5,100.00

636.00 5,724.00

11.00 319.00

2841.00 5,682.00

458.00 2,748.00

818.00 818.00

7470.00 7,470.00

Page 225: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

37,009.00

37,009.00

Page 226: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

144,464.00

Page 227: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

52.00 12,480.00

31.00 13,795.00

12.00 29,160.00

Page 228: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

55,435.00

55,435.00

54.00 1,080.00

56.00 336.00

58.00 116.00

58.00 696.00

60.00 240.00

64.00 128.00

66.00 66.00

82.00 410.00

74.00 1,628.00

68.00 136.00

89.00 356.00

96.00 1,344.00

Page 229: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

93.00 744.00

95.00 1,140.00

96.00 384.00

22.00 154.00

8,958.00

8,958.00

Page 230: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

133.00 1,596.00

160.00 3,840.00

723.00 1,446.00

59.00 236.00

61.00 122.00

61.00 122.00

61.00 244.00

69.00 276.00

72.00 144.00

80.00 160.00

80.00 160.00

83.00 166.00

86.00 172.00

89.00 178.00

104.00 208.00

Page 231: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

112.00 224.00

9,294.00

9,294.00

43.00 172.00

45.00 90.00

45.00 90.00

45.00 180.00

50.00 200.00

57.00 114.00

57.00 114.00

64.00 128.00

65.00 130.00

68.00 136.00

70.00 140.00

77.00 154.00

86.00 172.00

83.00 996.00

Page 232: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

42.00 1,008.00

44.00 528.00

23608.00 23,608.00

27,960.00

27,960.00

2277.00 4,554.00

2680.00 5,360.00

2277.00 4,554.00

2680.00 5,360.00

2277.00 4,554.00

Page 233: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2680.00 5,360.00

2277.00 4,554.00

2680.00 5,360.00

2680.00 2,680.00

2277.00 2,277.00

2277.00 2,277.00

2277.00 2,277.00

2680.00 2,680.00

2277.00 2,277.00

2277.00 2,277.00

2277.00 2,277.00

2971.00 2,971.00

2277.00 2,277.00

2277.00 2,277.00

2277.00 2,277.00

2971.00 2,971.00

2277.00 2,277.00

2277.00 2,277.00

2277.00 2,277.00

Page 234: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

78,282.00

78,282.00

5971.00 5,971.00

4049.00 4,049.00

1636.00 1,636.00

15.00 60.00

98.00 392.00

21.00 21.00

Page 235: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

12,069.00

191,998.00

7746.00 7,746.00

7665.00 7,665.00

28.00 28.00

585.00 585.00

Page 236: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1948.00 1,948.00

3463.00 3,463.00

217.00 217.00

3679.00 3,679.00

38.00 38.00

55.00 55.00

25,424.00

25,424.00

Page 237: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

5899.00 5,899.00

3819.00 3,819.00

3192.00 3,192.00

13.00 13.00

243.00 243.00

800.00 800.00

1421.00 1,421.00

84.00 84.00

1428.00 1,428.00

19.00 19.00

Page 238: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

16,918.00

16,918.00

23.00 23.00

3394.00 3,394.00

1088.00 1,088.00

Page 239: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

15704.00 15,704.00

23604.00 23,604.00

43,813.00

43,813.00

Page 240: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

12.00 1,392.00

11.00 484.00

9.00 504.00

19.00 2,014.00

58.00 696.00

92.00 1,840.00

9.00 180.00

19.00 912.00

19.00 836.00

9.00 180.00

Page 241: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

9,038.00

9,038.00

9.00 396.00

19.00 684.00

19.00 380.00

193.00 4,632.00

110.00 15,620.00

110.00 5,280.00

110.00 4,400.00

254.00 24,384.00

659.00 15,816.00

222.00 1,776.00

102.00 3,672.00

248.00 3,472.00

Page 242: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

80,512.00

80,512.00

222.00 5,328.00

175.00 3,500.00

129.00 1,290.00

Page 243: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

11139.00 11,139.00

Page 244: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

21,257.00

196,962.00

47.00 1,316.00

34.00 544.00

34.00 408.00

34.00 952.00

1255.00 15,060.00

4499.00 4,499.00

10.00 9,500.00

8.00 1,440.00

Page 245: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

33,719.00

33,719.00

1626.00 1,626.00

696.00 8,352.00

10.00 2,000.00

1084.00 1,084.00

Page 246: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

10.00 550.00

68.00 1,088.00

85.00 1,445.00

62.00 992.00

68.00 1,088.00

142.00 2,272.00

76.00 380.00

20,877.00

20,877.00

Page 247: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

65.00 325.00

2863.00 2,863.00

10.00 4,200.00

10.00 1,500.00

8.00 2,112.00

2914.00 34,968.00

Page 248: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

45,968.00

100,564.00

2.00 784.00

3.00 1,176.00

8.00 3,704.00

10.00 210.00

12.00 2,436.00

3.00 1,914.00

Page 249: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

4.00 1,356.00

11,580.00

11,580.00

1.00 638.00

1.00 676.00

Page 250: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836
Page 251: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1,314.00

12,894.00

658,047.00

33,871.00

20,292.00

65,001.00

43,122.00

376,966.00

219,746.00

53,652.00

5,580.00

0.00

47,027.00

15,088.00

144,464.00

191,998.00

196,962.00

100,564.00

12,894.00

Page 252: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2,185,274.00

13,111,644.00

13,111,644.00

Page 253: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Item Nr. Description Unit Qty

03 00 00 - CONCRETE

03 11 13 Structural Cast-in-Place Concrete Forming

1 Plain concrete 20MPa for blinding thickness 100mm for footing and 50mm under slab on grade m3 36

03 31 00 Structural Concrete

2 Reinforced concrete 35Mpa for strip footing m3 82

3 Reinforced concrete for sub structure for elevator pit m3 4

4 Reinforce concrete 35MPa for slab on grade with 7Ø8 / Liner meter thickness 150mm m3 51

5 Precost for super structure item 1

Concrete Topping

6 Structural screed will wiremesh 50mm thick for floor above hollow core slab m2 979

7 Sand cement foam concrete on roof avarage 75mm thick m2 346

8 Concrete Pads m2 8

9 Sand cement screed for floors to receive finishing 50mm thick m2 633

03 30 53 - Miscellaneous Cast-in-situ Concrete

10 300mm wide x 200mm high reinforced concrete 35 Mpa for lintel m m 23

11 100mm wide x 200mm thick reinforced concrete 35 Mpa for lintel m m 70

Page 254: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for CONCRETE

CARRIED TO SUMMARY

04 00 00 - Masonry

04 22 00 - Concrete Unit Masonry

Internal walls and Partitions

1 200mm thick CMU wall ,1 hour fire rated, m2 84

2 200mm thick CMU wall , 2 hour fire rated, m2 27

3 100mm thick CMU wall 2hr fire rated at shafts, m2 102

4 100mm thick CMU wall non fire rated m2 409

5 200mm thick 300mm high parapet CMU parapet wall at ground floor, non fire rated m2 17

Page 255: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for MASONRY

CARRIED TO SUMMARY

05 00 00 METALS

All metalworks herein shall be completed in full compliance with the Drawings A0-A401,

A0-A402, A0-A403 and Specification.

05 70 00 Decorative Metal

1 Supply and fix 50mm diameter stainless steel hand rails including but not limited to m 15

12mm diameter stainless steel balustrade, 40mm square stainless steel post with 50mm

x 120mm base plate, for staircase, floor mounted, kind, quality, fittings, fixtures,

accessories as shown on Drawing nr A0-A402 and as per Specification.

2 Supply and fix 50mm diameter stainless steel hand rails for staircase, wall mounted, m 12

kind, quality, fittings, fixtures, accessories as shown on Drawing nr A0-A402 and as per

Specification.

3 Supply and fix aluminum powder coated hand rails for balconies, floor mounted, kind, m 35

quality, fittings, fixtures, accessories as shown on Drawings nr A2-A502 and as per

Specification.

4 Supply and fix anti slip nosing strip for staircase, kind, quality, fittings, accessories as m 76

shown on Drawing nr A0-A402 and as per Specification.

05 00 00 Metals

Additional Items

5 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

As per Question and Answer No (65)

5.1 nr 1Galvanized steel ladder size 350 mm x 2500mm high @ elevator pit as shown in dwg No. (A3-A701)

Page 256: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for METALS

CARRIED TO SUMMARY

06 00 00 WOOD, PLASTICS, AND COMPOSITES

06 41 00 Architectural Wood Casework

As per Question and Answer No. (89) the kitchen cabinet changed to Aluminum

1 Supply and fix kitchen under counter cabinets (1450mm + 450mm) long 600mm wide nr 2

(counter tops measured separately) at kitchen with wall cabinet MDF melamine

laminated with aluminum edge, base cabinets with polished chrome cabinet pull

handles and all other accessories as per the Drawing nr A0-A902, A0-A903 and

Specification.

2 Supply and fix kitchen under counter cabinets 625 long 600mm wide (counter tops nr 2

measured separately) at kitchen with wall cabinet MDF melamine laminated with

aluminum edge, base cabinets with polished chrome cabinet pull handles and all other

Page 257: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

accessories as per the Drawing nr A0-A902, A0-A903 and Specification.

3 Supply and fix kitchen under counter cabinets (1300mm + 875mm) long 600mm wide nr 2

(counter tops measured separately) at kitchen with wall cabinet MDF melamine

laminated with aluminum edge, base cabinets with polished chrome cabinet pull

handles and all other accessories as per the Drawing nr A0-A902, A0-A903 and

Specification.

4 Supply and fix kitchen under counter cabinets 800mm long 600mm wide (counter tops nr 4

measured separately) at kitchen with wall cabinet MDF melamine laminated with

aluminum edge, base cabinets with polished chrome cabinet pull handles and all other

accessories as per the Drawing nr A0-A902, A0-A903 and Specification.

5 Supply and fix kitchen under counter cabinets (1350mm + 900mm) long 600mm wide nr 4

(counter tops measured separately) at kitchen with wall cabinet MDF melamine

laminated with aluminum edge, base cabinets with polished chrome cabinet pull

handles and all other accessories as per the Drawing nr A0-A902, A0-A903 and

Specification.

6 Supply and fix kitchen under counter cabinets 1200mm long 400mm wide (counter tops nr 6

measured separately) at kitchen with wall cabinet MDF melamine laminated with

aluminum edge, base cabinets with polished chrome cabinet pull handles and all other

accessories as per the Drawing nr A0-A902, A0-A903 and Specification.

Page 258: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Wood, Plastics, and Composites (Cont'd)

1 Supply and fix kitchen under counter cabinets 1450mm long 400mm wide (counter tops nr 2

measured separately) at kitchen with wall cabinet MDF melamine laminated with

aluminum edge, base cabinets with polished chrome cabinet pull handles and all other

accessories as per the Drawing nr A0-A902, A0-A903 and Specification.

2 Supply and fix kitchen overhead counter cabinets 2650mm long 275mm wide 870MM nr 2

height (countertops measured separately) at kitchen with wall cabinet MDF melamine

laminated with aluminum edge, overhead cabinets with polished chrome cabinet pull

handles and all other accessories as per the Drawing nr A0-A902, A0-A903 and

Specification.

3 Supply and fix kitchen overhead counter cabinets 3300mm long 275mm wide 870mm nr 6

height (counter tops measured separately) at kitchen with wall cabinet MDF melamine

laminated with aluminum edge, overhead cabinets with polished chrome cabinet pull

handles and all other accessories as per the Drawing nr A0-A902, A0-A903 and

Specification.

06 61 16 Solid Surfacing Fabrications

4 Supply and fix solid acrylic counter top shaped 1100 long 575mm wide with opening for nr 8

wash basin as shown in the Drawing nr A0-A902, A0-A903 and Specification.

5 Supply and fix solid acrylic counter top shaped 600 long 400mm wide with opening for nr 6

wash basin as shown in the Drawing nr A0-A902, A0-A903 and Specification.

6 Supply and fix solid acrylic counter top shaped 900 long 550mm wide with opening for nr 4

wash basin as shown in the Drawing nr A0-A902, A0-A903 and Specification.

7 Supply and fix Solid Acrylic counter top shaped (2300mm+1300mm) long 600mm depth nr 6

with opening for double bowl kitchen sink including 100mm up stand for counter top as

shown in the Drawing nr A0-A904 and Specification.

8 Supply and fix Solid Acrylic counter top shaped (1675mm+1450mm) long 600mm depth nr 2

with opening for double bowl kitchen sink including 100mm up stand for counter top as

shown in the Drawing nr A0-A904 and Specification.

Page 259: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Wood, Plastics, and Composites (Cont'd)

1 Supply and fix Solid Acrylic counter top shaped 1200mm long 400mm width at kitchen nr 6

including 100mm up stand for counter top as shown in the Drawing nr AO-A94 and

Specification.

2 Supply and fix Solid Acrylic counter top 1450mm long 400mm width for counter top in nr 2

kitchen as shown in the Drawing nr AO-A904 and Specification.

06 00 00 Wood, Plastics, and Composites

Additional Items

3 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

As per Question and Answer No. 353

3.1 MDF Laminated Shelf ; Size 3400mm length x 500mm high nr 4

Page 260: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for WOOD, PLASTICS, AND COMPOSITES

CARRIED TO SUMMARY

07 00 00 THERMAL AND MOISTURE PROTECTION

1 Waterproofing works for substructure with vapour barrier 250 microns, horizontal m2 372

2 Two coats of bitumen paint for sub structure including elevator pit walls for vertical surface. m2 228

3 Ditto for horizontal surface m2 166

Wet Area Waterproofing

4 Waterproofing works for wet area, vertical surface, m2 221

5 Ditto for , horizontal surface, m2 120

Roof Waterproofing

6 Waterproofing membrane for roof and balcony, horizontal surface, width > 300mm, m2 346

(kind, quality, method of fixing, thickness as per the Drawings and Specification)

7 Geotextile layer for roof and balcony water proofing works, horizontal surface, width > m2 346

300mm, (kind, quality, method of fixing, thickness as per the Drawings and Specification)

8 100mm thick insulation for water proofing works at roof and balcony water proofing m2 346

works, horizontal surface, width > 300mm, (kind, quality, method of fixing, thickness as

per the Drawings and Specification)

Roof Hatches

Page 261: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

9 Roof Hatch nr 1

10 Smoke Vent nr 1

11 Anti-vibration insulation m2 44

Total for THERMAL AND MOISTURE PROTECTION

CARRIED TO SUMMARY

08 00 00 OPENINGS

All works herein shall be completed in full compliance with the Doors & Windows Note

Schedule Drawings A0-A801, A0-A802, A0-A803 and Specification.

Note: Notwithstanding the Provisions of the Standard Method of Measurement, door

sets including doors, frames, vision panels, decoration and ironmongery have been

measured as a composite item and the Contractor should make due reference to the

drawings and specification. No claim for lack or want of knowledge will be entertained

08 13 00 Aluminum Doors

1 Supply and fix aluminum door with fixed double glazed panel, 1600mm wide x 2700mm nr 1

high with 6mm low glass +16+6mm clear glass vision panel including frame, type D4,

finished with and including paint, all accessories and hardware including but not limited

to hinges HDH type, outside and inside door lock, lever handles and latch, wall stop,

roses, weather stripping and escutcheons as stated on the drawings and in in the

Specification.

08 14 00 - Wood Doors

As per Q&A No. 380

2 Supply and fix wooden flush teak veneer door, 54mm thick, 1000mm wide x nr 8

2200mm high including frame, type D1,30 minutes fire rated, finished with and including

paint, all accessories and hardware including but not limited to hinges BBS type, outside

door lock, lever handles and latch, wall stop, roses and escutcheons as stated on the

drawings and in the Specification.

3 Supply and fix wooden flush teak veneer door, 44mm thick, 900mm wide x nr 16

2200mm high including frame, type D2, finished with and including paint, all accessories

and hardware including but not limited to hinges BBS type, outside door lock, lever

handles and latch, wall stop, roses and escutcheons as stated on the drawings and in the

Specification.

4 Supply and fix wooden flush door, 44mm thick, 800mm wide x 2200mm high including nr 16

frame, type D3, finished with and including paint, all accessories and hardware including

but not limited to hinges BBS type, outside door lock, lever handles and latch, wall stop,

roses and escutcheons as stated on the drawings in the Specification.

Page 262: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

OPENINGS(Confd)

1 Supply and fix wooden flush door, 54mm thick, 1000mm wide x 2200mm high with nr 3

6mm low glass +16+6mm clear glass vision panel 200mm x 900mm including frame,

type D5,90 minutes fire rated, finished with and including paint, push bar panic door all

accessories and hardware including but not limited to hinges BBS type, lever handles and

latch, wall stop, roses and escutcheons as stated on the drawings and in the Specification.

2 Supply and fix wooden flush teak veneer door, 54mm thick, 1000mm wide x nr 3

2200mm high including frame, type D6,90 minutes fire rated, finished with and including

paint, all accessories and hardware including but not limited to hinges BBS type, outside

and inside door lock, lever handles and latch, wail stop, roses and escutcheons as stated

on the drawings and in the Specification.

3 Supply and fix wooden flush teak veneer door, 54mm thick, 1000mm wide x nr 1

2200mm high with 6mm low glass +16+16mm clear glass vision panel 200mm x 900mm

including frame, type D7,90 minutes fire rated, finished with and including paint, all

accessories and hardware including but not limited to hinges BBS type, inside door lock,

push/panic door, lever handles and latch, wall stop, roses and escutcheons as stated on

the drawings and in the Specification.

08 51 13 Aluminum Windows

4 Supply and fix aluminum double glazed window, powder coated, 4300mm wide x nr 2

1925mm high, glass panel with open glass door window including frarne,2150mm

wide x 1925mm high aluminum shutters in front of sliding glass panel, type W1, finished,

all accessories and hardware including but not limited to hinges, handle, lock, weather

tight strip etc. as stated in the Drawings and Specification.

5 Supply and fix aluminum double glazed window, powder coated, 4150mm wide s nr 2

1925mm high, glass panel with open glass door window including frame,2075mm

wide x 1925mm high aluminum shutters in front of sliding glass panel, type W2, finished,

all accessories and hardware including but not limited to hinges, handle, lock, weather

tight strip etc. as stated in the Drawings and Specification.

Page 263: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

OPENINGS(Cont'd)

1 Supply and fix aluminum double glazed window, 4150mm wide x 3000mm high, powder nr 4

coated, glass panel with open glass door window including frame, 2075mm wide

x 1925mm high aluminum fixed shutters in front of sliding glass panel only, type W3, finished, all

accessories and hardware including but not limited to hinges, handle, lock, weathertight

strip etc. as stated in the Drawings and Specification.

(No glass balustrade is provided, refer to DWG. No. A0-802,A0-803 and A0-901)

2 Supply and fix aluminum double glazed window, 4150mm wide x 3000mm high, nr 6

glass panel with open glass door window, powder coated including frame, W3a, finished,

all accessories and hardware including but not limited to hinges, handle, lock, weather

tight strip etc. as stated in the Drawings and Specification.

3 Supply and fix aluminum double glazed window, 4150mm wide x 30D0mm high, powder nr 2

coated, glass panel with open glass door window including frame, 2075mm wide

x 1925mm high aluminum fixed shutters in front of sliding glass panel only, type W4, finished, all

accessories and hardware including but not limited to hinges, handle, lock, weather tight

strip etc. as stated in the Drawings and Specification.

(No glass balustrade is provided, refer to DWG. No. A0-802,A0-803 and A0-901)

4 Supply and fix aluminum double glazed window, 4150mm wide x 3000mm high, nr 6

glass panel with open glass window including frame, powder coated, sliding glass panel,

type W4a, finished, all accessories and hardware including but not limited to hinges,

handle, lock, weather tight strip etc. as stated in the Drawings and Specification.

5 Supply and fix aluminum double glazed window, 2550mm wide x 3000mm high, nr 1

glass panel with open glass door window including frame, powder coated, 1275mm wide

x 3000mm high aluminum shutters in front of sliding glass panel type, W12, finished, all

accessories and hardware including but not limited to hinges, handle, lock, weather tight

strip etc. as stated in the Drawings and Specification.

6 Supply and fix aluminum double glazed window, 2550mm wide x 2500mm high, nr 1

glass panel with open glass door window including frame, 1275mm wide x 3o00mm high

aluminum shutters in front of sliding glass panel, type W13, finished, all accessories and

hardware including but not limited to hinges, handle, lock, weather tight strip etc. as

stated in the Drawings and Specification.

Page 264: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

OPENINGS(Cont'd)

1 Supply and fix aluminum double glazed window, 650mm wide x 1925mm high, nr 20

glass panel with open glass door window including frame, fixed louvers 650mm wide x

550mm high, type W20, finished, all accessories and hardware including but not limited

to hinges, handle, lock, weather tight strip etc. as stated in the Drawings and

Specification.

08 83 00 Mirrors

2 Supply and fix fixed mirror 1100mm width x 1075mm high for bathrooms (size, kind, nr 8

quality, surface treatment, method of jointing, etc. as per the Drawings nr A0-A902, A0-

A903 and Specification).

3 Supply and fix fixed mirror 610mm width x 1075mm high for bathrooms (size, kind, nr 6

quality, surface treatment, method of jointing, etc. as per the Drawings nr A0-A902, A0-

A903 and Specification).

4 Supply and fix fixed mirror 900mm width x 1725mm high for bathrooms (size, kind, nr 4

quality, surface treatment, method of jointing, etc. as per the Drawings nr A0-A902, A0-

A903 and Specification).

Page 265: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

OPENINGS(Cont'd)

08 00 00 Openings

Additional Items

1 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Total for OPENINGS

CARRIED TO SUMMARY

09 00 00 - FINISHES

09 23 00 Gypsum Board wall

1 Gypsum wall above wooden cabinet closet m2 25

09 24 00 Cement Plastering

2 15mm thick internal Plastering for block walls to receive paint m2 836

3 Plastering for walls to receive tiling at wet areas, m2 111

Page 266: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

FINISHES (Cont'd)

09 30 13 Ceramic Tiling

Floor Tiling

1 Porcelain tile flooring (type - FT1), size 600mm x 600mm, m2 766

2 Terrazzo tiles, size 400x400mm at roof m2 304

Wall tiling

3 Mosaic tile (type WT4) 100mm x 300mm size for kitchen walls, m2 143

4 White body wall tile (type WT1) 325mm x 977mm size for toilets and bathroom walls, m2 372

Skirting

5 MDF skirting 100mm height, m 412

6 Porcelain skirting 100mm height, for stair case m 46

7 Ditto for Balcony m 15

Stair Finish

8 Porcelain tile tread (type - FT1), 230mm wide x 1350mm length, m 47

9 Porcelain tile for riser (type - FT1), 160mm high x 1350mm length, m 53

Threshold

10 Porcelain tile threshold (type - FT1), 200mm wide x 800mm length, m 18

Page 267: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

FINISHES (Cont'd)

09 50 00 Ceilings

1 Supply and install gypsum ceiling, depth of suspension 500 - 1000 mm m2 169

as per the Drawings nr A2-A906,A0-A821

2 Supply and install Moisture resistant gypsum board ceiling at kitchen m2 46

3 Supply and install Moisture resistant gypsum ceiling for toilets laundary and bathrooms m2 72

09 75 13 Stone Wall Facing

4 Stone slab 400mm wide for parapet walls at ground floor, m 18

Page 268: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

09 91 00 - Painting

Wall -Painting

5 Painting for walls, m2 1320

6 Painting for walls in staircases, m2 153

Ceiling -Painting

7 Painting for ceiling m2 486

8 Painting for staircase ceiling m2 47

9 Painting for gypsum board ceiling m2 286

Total for FINISHES

CARRIED TO SUMMARY

10 00 00 SPECIALTIES

10 28 00 –Toilet, Bath and Laundry Accessories

All Fire suppression works herein shall be completed full incompliance with the Drawings

nr SA-M011, SA-M012, SA-F201, SA-F202, 5A-F203, SA-F204 and Specification.

1 Tissue paper holder (TPH) nr 18

2 Soap dispenser (SD) nr 12

3 Mixer tap W/shower head (MTFS) nr 12

4 Towel ring nr 12

Page 269: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

5 Robe hook nr 12

6 Towel bar nr 12

10 44 13.13 Portable Fire Extinguishers

All items hereunder to be Supply and installed with all necessary accessories, all in

accordance with the specifications and drawings.

7 Supply and install Multipurpose dry chemical fire extinguisher nr 8

8 Supply & install fire blanket nr 8

10 57 00 Wardrobe and Closet Specialties

9 Supply and fix closets 2850 mm length, 600mm depth, 2400mm high, type BIC01, with nr 10

MDF laminated dark wood veneer shelves, door with MDF white matt lacquer finish and

chromed stainless steel handles, and all other accessories as per the Drawing nr AO-A932

and Specification.

SPECIALTIES (Cont'd)

10 22 23 Portable Partitions, Screens, and Panels

1 Supply and fix shower screen 8mm thick tempered glass 1150mm x 2000mm high nr 2

partition with 700mm x 2000mm sliding door, finished, all accessories and hardware

including but not limited to hinges, handle, etc. as stated in the Drawing nr A0-A904 and

Specification.

2 Supply and fix shower screen 8mm thick tempered glass 1020mm x 2000mm high nr 10

partition, finished, all accessories and hardware Including but not limited to hinges,

handle, etc. as stated in the Drawing nr AO-A904 and Specification.

10 00 00 Specialties

Additional Items

3 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Page 270: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3.1 B1 Co2 nr 4

3.2 B1 Co3 nr 4

3.3 Towel Pin nr 16

Total for SPECIALTIES

CARRIED TO SUMMARY

11 00 00 EQUIPMENT

All items hereunder to be described with information such as appropriate to the

procurement , design, supply, execution, type, kind, quality, size, method of fixing ,

specified codes of practice, etc. as per the Drawings and Specification).

11 30 00 Residential Equipment

1 Refrigerator/freezer nr 8

2 Exhaust hoods nr 8

3 Cooker nr 8

4 Washing Machine nr 8

11 00 00 Equipment

Additional Items

5 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Page 271: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for EQUIPMENT

CARRIED TO SUMMARY

12 00 00 FURNISHING

All items hereunder to be described with information such as appropriate to the

procurement , design, supply, execution, type, kind, quality, size, method of fixing ,

specified codes of practice, etc. as per the Drawings and Specification).

12 00 00 Furnishing

Additional Items

1 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Total for FURNISHING

CARRIED TO SUMMARY

14 00 00 - CONVEYING EQUIPMENT

14 10 10 - PASSENGER ELEVATORS

Contractor Designed Elevators

Supply and install 6 person passenger machine room less lift to serve three floors; refer

Specification for performance capacity, weight load, speed of travel, call system etc.; car

to include floor finish to be as per entrance hallway, mirrored and hardwood ceiling with

recessed and emergency lighting, mirrored and hardwood wall finish, chromium plated

handrails, floor indicator, floor push buttons (including braille floor indicators),

emergency call button/alarm, emergency intercom; each floor to have call button and

floor indicator all as manufacturers recommendations

1 Elevator nr 1

Page 272: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for CONVEYING EQUIPMENT

CARRIED TO SUMMARY

21 00 00 FIRE SUPPRESSION

All Fire suppression works herein shall be completed full incompliance with the Drawings

nr SA-M011, SA-M012, SA-F201, SA-F202, SA-F203, SA-F204 and Specification.

21 12 00 Fire Suppression Standpipes

Supply & Installation testing and commissioning of steel pipes (painted). All fire fighting

pipes to be completed including but not limited to accessories, fittings, couplings

according to NFPA code/ local civil defense code. Including all kind of supports and

hangers all in accordance to the specificaFons and drawings.

1 Ditto, 65 mm diameter m 23

21 11 19 Fire-Department Connection

2 Fire Connection Department including Non- return Valve, 65mm dia. nr 1

21 12 13 Fire-Suppression Hoses and Nozzles

Fire hose reel cabinet C/W 2-1/2" pressure restricted type landing valve 2-1/2"

svnthetic hose. 1" automatic swinging hose reel, and multipurpose dry powder

extinguisher. The rate also shall be include all set of valves (landing , gate, angle,

PRV,etc-I , Pressure gauges.

3 Fire Hose Cabinet. nr 3

21 12 23 Fire-Suppression Hose Valves

Supply and installation valves complete and all necessary accessories, all in accordance

with the specifications and drawings.

Page 273: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

4 Gate Valve , 65mm diameter nr 1

Automatic Air Vent

Supply and Installation of automatic air vent, all in accordance with the specifications

and drawings.

5 65 mm diameter. nr 1

FIRE SUPPRESSION (Cont'd)

GENERAL

TESTING, ADJUSTING, AND BALANCING OF MEP SYSTEMS

1 Allow for Starting up, pressure testing, complete testing and commissioning for all Fire Item 1

fighting system, including all necessary preparations and attendance for authority

approvals.

2 Allow for drawing, manuals, approvals & instruction books. Item 1

3 Allow for protective and decorative painting Item 1

4 Allow for liaison and coordination with local authorities. Item 1

5 The contractor to list here and price any items shown in the drawings, mentioned in the

specifications or required for the satisfactory completion of this section as per the

relevant authority regulations, but not mentioned here. Any such item not listed is

deemed to be included.

21 00 00 Fire Suppression

Additional Items

Page 274: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

6 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Total for FIRE SUPPRESSION

CARRIED TO SUMMARY

22 00 00 - PLUMBING

All items hereunder to be described specified code of practice and regulations, kind,

quality, size, method of fixing , finishes or surface treatments, etc. as per the Drawings

and Specification).

Page 275: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

22 05 23 General-Duty Valves for Plumbing Piping

Valves

Valves are classified according to type . Material and/or size . Rates include furnishing

and installing of valves, testing at manufacturer's premises and on site; diameters of

valves and water meter according to pipe diameter which will be connected with it; as

per Drawings and Specification.

Gate Valve

1 20 mm diam. nr 4

2 25 mm diam. nr 36

3 32 mm diam. nr 4

4 40 mm diam. nr 12

5 63 mm diam. nr 2

6 75 mm diam. nr 4

Angle Valve

7 20 mm diam. nr 55

8 25 mm diam. nr 18

Check Valve

9 20 mm diam. nr 6

Globe Valve

10 20 mm diam. nr 2

11 25 mm diam. nr 18

12 40 mm diam. nr 2

Non-Return Valve

13 32 mm diam. nr 2

14 40 mm diam. nr 6

Page 276: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

15 50 mm diam. nr 2

Pressure Reducing Valve

16 75 mm diam. nr 1

22 11 16 Domestic Water Piping

Domestic water piping is classified by material and diameter. Rates include furnishing

and installing of pipes, fittings, accessories, fixing supports, joints, sleeves, special parts,

connections, hanger supports. Rates to include all works and materials necessary for

complete installation for piping system as per the Drawings and Specification.

Water Supply System

1-Cold Water Supply

1 75 mm diameter. m 26

2 63 mm diameter. m 52

3 50 mm diameter. m 11

4 40 mm diameter. m 22

5 32 mm diameter. m 15

6 25 mm diameter. m 365

7 20 mm diameter. m 207

2-Hot Water Supply

8 20 mm diameter. m 201

3 - Accessories

9 Hose Bibb 20mm . nr 2

10 Water Meter 40 mm. nr 6

11 Water Meter 32 mm. nr 2

12 Water Hammer Arrestor nr 20

Page 277: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

13 Automatic Air Vent. nr 20

14 Pressure Gauge . nr 2

15 Strainer 75 mm. nr 1

22 13 16 Sanitary Waste and Vent Piping

Sanitary Pipe Works

Sanitary pipe works is classified by material and diameter. Rates include furnishing and

installing of pipes, fittings, accessories, fixing support, joints, sleeves , special parts,

connections, hanger supports. Rates for pipework below ground also include

excavation, backfilling , civil work, trenches and any other accessories or fittings

necessary for complete installation of the piping system. Testing of pipes at the

manufacturer's premises is included. All as per the Drawings and Specification.

Pipes and fitting above ground

Waste Pipe

16 50 mm diameter. m 26

17 75 mm diameter. m 22

18 110 mm diameter. m 105

Soil Pipe

19 110 mm diameter. m 65

Pipes and fitting below ground

Waste pipe

1 75 mm diameter. m 4

2 110 mm diameter. m 55

Soil Pipe

3 110 mm diameter. m 110

Page 278: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Vent Pipe Works

Vent pipes are classified by material and diameter. Rates include furnishing and installing

of pipes, fittings, accessories, fixing support, joints, sleeves, special parts, connections,

hanger supports. Rates include furnishing and installing of pipes, fittings, accessories,

fixing support, joints, sleeves , special parts, connections, hanger supports. Rates for

pipework below ground also include excavation, backfilling , civil work, trenches and any

other accessories or fittings necessary for complete installation of the piping system.

Testing of pipes at the manufacturer's premises is included. All as per the Drawings and

Specification.

Pipes and fittings above ground

4 75 mm diameter. m 115

Pipes and fitting below ground

5 75 mm diameter. m 10

22 13 19.13 Sanitary Drains

Sanitary drains (to include rainwater pipework and condensate drain pipework) are

classified by material and diameter. Rates include furnishing and installing of pipes,

fittings, accessories, fixing supports, joints, sleeves, special parts, connections, hanger

supports. Rates also include testing of pipes at the manufacturer's premises. All as per

the Drawings and specification.

Rain water Pipe

6 75 mm diameter. m 110

Condensate Drain Pipe Works

7 20 mm diameter. m 105

8 25 mm diameter. m 13

Page 279: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

PLUMBING (Cont'd)

22 33 00 Electric Domestic Water Heaters

Electric domestic water heaters are classified according to capacity. Rates include

furnishing of heater complete with safety valves, air vent, pressure and temperature

relief gauges, drain valves, all valves set (angle, gate, non return, etc. .), thermostat,

heating element, contactors, switch, support, bolts, nuts, connection of pipes, testing on

site, commissioning and putting into service.

1 EWH--A3-01 with (30 litres / 1200 W) capacity. nr 14

2 EWH-A3-02 with (100 litres / 1500 W} nr 12

22 40 00 Plumbing Fixtures

All items described hereunder to be of kind, quality, size, nature of base, method of

fixing, complete with accessories etc. as per the Drawings nr V1-903 and Specification

3 Floor Drain (FD) nr 29

4 Flexible Shower Hose(Sprayer ,valve , etc.) nr 18

5 Water Closet nr 18

6 Floor clean out nr 4

7 Roof drain nr 9

8 Vent cap nr 6

9 Bath tub (BT) including taps, plug, accessories and fitting. nr 0

As per the drawing it is integrated

10 Wash basin (WB) nr 18

As per Q&A no. 358 clothes washer not in contract, only connection

11 Washing machine connections (washing machine not in contract) nr 8

As per Q&A no. 360 shower channel to be used

12 Shower (SHO) including shower channel, mixer tap, fitting, spray and adjustable bar nr 12

Page 280: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

As per Q&A-383, the sink bowl is

13 Kitchen sink nr 8

14 Taps for wash basin including fittings , plugs, valves, connections and waste. nr 18

15 Mixer tap for kitchen sink including fitting, plugs, chrome plated pipes, valves and nr 8

waste

PLUMBING (Cont'd)

22 00 00 - Plumbing

Additional Items

1 Inspection chamber as per Drawings and Specification; connected directly to nr 9

sewer network.

2 Clean out (CO) nr 16

3 Roof Water tank as per Specification; rate shall be include supplying and nr 2

installing, all fittings, accessories, valves, pipework, vents etc. as per the Drawings

and Specification

4 Balcony Drain nr 8

Page 281: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

5 Gully Trap nr 6

Additional Items

Marking the position of holes, mortices and chases in the structure Item 1

Identification; plates, discs, labels, tapes, bands, arrows, symbols, letters, numbers and Item 1

charts; as stated on drawings and in Specification

6 Testing and commissioning of entire installation Item 1

7 Preparation of as-built drawings Item 1

8 Preparation of operation and maintenance manuals Item 1

9 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Total for PLUMBING

CARRIED TO SUMMARY

23 00 00 - HEATING, VENTILATING, AND AIR CONDITIONING (HVAC)

All HVAC works shall be completed as per the Drawings and Specification.

23 07 13 Duct Insulations

All items hereunder to be described with in type, kind, quality, thickness, method of

fixing , specified codes of practice, etc. as per the Drawings and Specification).

1 Supply and fix ductwork insulations outdoor for (supply, return, fresh air, exhaust, etc.); m2 182

air duct to include fixing and accessories as per the Drawings and Specification

23 23 00 Refrigerant Piping

Supply and fix refrigerant pipes for FCU from condensing units to indoor installed AC

units including fittings, sleeves and all accessories as per the Drawings and Specification

2 Pipes including max. liquid line; see drawings and specification for pipe sizes m 260

23 31 00 HVAC Ducts and Casings

Page 282: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

All items hereunder to be described with in type, kind, quality, size, method of fixing ,

specified codes of practice, and method of fixing supports, etc. as per the Drawings and

Specification).

Notwithstanding the provisions of the Standard Method of Measurement, internal

ductwork is to include insulation to the ductwork. No claim for additional cost due to

lack or want of knowledge will be entertained

3 Supply and fix insulated indoor galvanized steel sheet metal duct work for all HVAC work Kg 1860

as specified and as indicating on drawings, complete with bends, supports, connections,

fittings, splices and all accessories to complete the work.

23 33 13.13 Volume-Control Dampers

All items hereunder to be described with ,type, kind, quality, size, method of fixing ,

specified codes of practice, etc. as per the Drawings and Specification).

Volume Dampers

1 Volume Damper ; 100x100 mm . nr 14

2 Volume Damper ; 150x100 mm . nr 6

3 Volume Damper ; 150x150 mm nr 4

4 Volume Damper ; 150 mm dia. circular damper. nr 8

5 Volume Damper ; 200x150 mm . nr 2

6 Volume Damper ; 200x200 mm . nr 4

7 Volume Damper ; 250x200 mm . nr 2

8 Volume Damper ; 300x200 mm . nr 1

9 Volume Damper ; 300x150 mm . nr 2

10 Volume Damper ; 300x300 mm . nr 2

11 Volume Damper ; 300x350 mm . nr 1

12 Volume Damper ; 400x300 mm . nr 12

Page 283: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

13 Volume Damper ; 400x350 mm . nr 4

14 Volume Damper ; 400x400 mm . nr 4

15 Volume Damper ; 500x400 mm . nr 6

Splitter Dampers

16 Splitter Damper nr 1

HEATING, VENTILATING, AND AIR CONDITIONING (Cont'd)

23 33 13.16 Fire Dampers

As per Q&A-362, the word "motorized" to be deleted in the description

All items hereunder to be described with information such as type, kind, quality, size,

method of fixing , specified codes of practice, etc. as per the Drawings and Specification).

17 Fire Damper ; Size 100 x 100 mm. nr 8

18 Fire Damper ; Size 100 x 150 mm. nr 6

19 Fire Damper ; Size 150 x 150 mm. nr 4

23 33 46 Flexible Ducts

All items hereunder to be described with in type, kind, quality, size, method of fixing ,

specified codes of practice and method of fixing supports, etc. as per the

Drawings and Specification).

1 Supply and install Flexible duct with insulation ; size diam 150 mm . m 4

23 34 00 HVAC Fans

Page 284: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

All items hereunder to be described with information such as appropriate to the

procurement , capacity, design, supply, execution, type, kind, quality, size, method of

fixing , specified codes of practice, etc. as per the Drawings and Specification).

Supply and install exhaust fan as specified and as indicated in drawing. Fan consists of

casing, fan, motor, control, filter, screen, sand trap louver, all electrical works

(components, wiring, etc.) and all accessories. Electrical power supply 220/1/60.

Wall Mounted

2 Exhaust Fan (EF-01) 50 Pa with total air flow 25 L/S nr 8

Ceiling Mounted

3 Exhaust Fan (EF-02 ) 100 Pa with total air flow 25 L/S . nr 18

Range Hood Fan

4 Range Hood Fan (RH-01) ;150 Pa with total air flow 50 L/S . nr 8

Garbage Exhaust fan

5 Garbage Exhaust fan (GEF-01/GEF-02) ;150 Pa with total air flow 60 L/S . nr 2

23 37 00 Air outlets and Inlets

All items hereunder to be described with information such as type, kind, quality, size,

method of fixing , specified codes of practice, etc. as per the Drawings and Specification).

Supply and install Painted Supply linear bar air Register with complete accessories.as

per the Drawings and Specification.

6 Size 450x200 mm ; 260 L/s . nr 2

7 Size 500x200 mm ; 280 L/s . nr 2

8 Size 500x200 mm ; 460 L/s . nr 2

9 Size 600x200 mm ; 470 L/s . nr 2

10 Size 650x200 mm ; 265 L/s nr 2

11 Size 750x200 mm ; 300 L/s. nr 2

12 Size 750x250 mm ; 365 L/s. nr 2

Page 285: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

HEATING, VENTILATING, AND AIR CONDITIONING (Cont'd)

1 Size 800x200 mm; 315 L/s. nr 2

2 Size 850x200 mm; 345L/s nr 2

3 Size 850x250mm; 400L/s. nr 2

4 Size 1050x200 mm ; 440L/s. nr 2

5 Size 1050x250 mm; 520L/s. nr 2

Supply and install Painted Return linear bar air grille with complete accessories.as per

the Drawings and Specification.

6 Size 450x200mm;260L/s nr 2

7 Size 500x200 mm ; 280L/s nr 2

8 Size 500x200 mm ; 460 L/s. nr 2

9 Size 600x200 mm ; 470 L/s . nr 2

10 Size 650x200 mm ; 265 L/s. nr 2

11 Size 750x200 mm ; 300L/s. nr 2

12 Size 750x250 mm ; 365 L/s. nr 2

13 Size 800x200 mm ; 315 L/s . nr 2

14 Size 850x200 mm ; 345L/s . nr 2

15 Size 850x250mm ; 400L/s . nr 2

16 Size 1050x200 mm ; 440L/s . nr 2

Page 286: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

17 Size 1050x250 mm ; 520L/s . nr 2

Supply and install 3 way Supply ceiling diffuser with complete accessories.as per the

Drawings and Specification.

18 Size 150X150 mm ; 40 L/s. nr 8

Supply and install exhaust air louver with complete accessories as per the Drawings

and Specification.

19 Exhaust air louver (150X100)mm . nr 18

20 Exhaust air louver (200X150)mm . nr 8

23 82 00 Convection Heating and Cooling Units

All items hereunder to be described with information such as appropriate to the

procurement , capacity, design, supply, execution, type, kind, quality, size, method of

fixing , specified codes of practice, etc. as per the Drawings and Specification).

Supply and install fresh air handing unit as specified and as indicated in drawing. Unit

to be complete with air cooled condensing unit, fan, pre-filter, bag filter, damper and

sand trap louver with filter, valves, controls, all electrical works (components, wiring ,

etc.) and all accessories. Electrical power supply 380/3/60

1 (FAHU-A3-01) , 660 L / s , 350 Pa ; Total load 26.1 KW . nr 1

Supply and install concealed fan coil unit as specified and as indicated on drawings.

Unit to be complete with air cooled condensing unit, fan, filter, valves, control,

thermostat, all electrical works (components , wiring , etc. .) and all accessories.

Page 287: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Electrical power supply 220/1/60.

Ground Floor

2 (FCU-GF1-01), 260 L / s , 75 Pa ; Electrical data power 1.8 KW . nr 1

3 (FCU-GF1-02) , 472 L / s , 75 Pa ; Electrical data power 3.6 KW . nr 1

4 (FCU-GF2-01) , 261 L / s , 75 Pa ; Electrical data power 1.8 KW nr 1

5 (FCU-GF2-02), 472 L / s , 75 Pa ; Electrical data power 3.6 KW nr 1

6 (FCU-GF3-O1) , 282 L / s , 75 Pa ; Electrical data power 1.8 KW . nr 1

7 (FCU-GF3-02), 462 L / s , 75 Pa ; Electrical data power 3.6 KW . nr 1

8 (FCU-GF4-01), 283 L / s , 75 Pa ; Electrical data power 1.8 KW . nr 1

9 (FCU-GF4-02), 461 L / s , 75 Pa ; Electrical data power 3.6 KW . nr 1

First Floor

9 (FCU-FF1-01) , 480 L / s , 75 Pa ; Electrical data power 3.6 KW . nr 1

10 (FCU-FF1-02) , 343 L / s , 75 Pa ; Electrical data power 2.7 KW . nr 1

11 (FCU-FF1-03) , 314 L / s , 75 Pa ; Electrical data power 2.7 KW . nr 1

12 (FCU-FF1-04) , 265 L / s , 75 Pa ; Electrical data power 1.8 KW . nr 1

13 (FCU-FF2-01) , 480 L / s , 75 Pa ; Electrical data power 3.6 KW . nr 1

14 (FCU-FF2-02) , 344 L / s , 75 Pa ; Electrical data power 2.7 KW . nr 1

15 (FCU-FF2-03) , 314 L / s , 75 Pa ; Electrical data power 1.8 KW . nr 1

16 (FCU-FF2-04) , 265 L / s , 75 Pa ; Electrical data power 1.8 KW . nr 1

Page 288: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

HEATING, VENTILATING, AND AIR CONDITIONING (Cont'd)

Second Floor

1 (FCU-LF1-01) , 558 L / s , 75 Pa ; Electrical data power 3.6 KW . nr 1

2 (FCU-LF1-02) , 395 L / s , 75 Pa ; Electrical data power 2.7 KW . nr 1

3 (FCU-LF1-03) , 365 L / s , 75 Pa ; Electrical data power 2.7 KW . nr 1

4 (FCU-LF1-04) , 301 L / s , 75 Pa ; Electrical data power 1.8 KW . nr 1

5 (FCU-LF2-01) , 559 L / s , 75 Pa ; Electrical data power 3.6 KW nr 1

6 (FCU-LF2-02) , 396 L / s , 75 Pa ; Electrical data power 2.7 KW . nr 1

7 (FCU-LF2-03) , 366 L / s , 75 Pa ; Electrical data power 2.7 KW nr 1

8 (FCU-LF2-04) , 301 L / s , 75 Pa ; Electrical data power 1.8 KW . nr 1

23 05 93 Testing, Adjusting and Balancing for HVAC

All items hereunder to be described with type of installation, preparatory operations,

stages of test (nr), required attendance, applicable codes etc. as per the Drawings and

Specification).

1 Air balancing of the ducting network Item 1

2 Testing, balancing and commissioning of all the equipment Item 1

HEATING, VENTILATING, AND AIR CONDITIONING (Cont'd)

Additional Items

Page 289: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1 Marking the position of holes, mortices and chases in the structure Item 1

2 Identification; plates, discs, labels, tapes, bands, arrows, symbols, letters, numbers and Item 1

charts; as stated on drawings and in Specification

3 Testing and commissioning of entire installation Item 1

4 Preparation of as-built drawings Item 1

5 Preparation of operation and maintenance manuals Item 1

6 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

6.01 Exhaust air grille (100X100)mm . nr 3

6.02 Fresh air Grille (250X200)mm . nr 1

Total for HVAC

CARRIED TO SUMMARY

26 00 00 - ELECTRICAL

All works hereunder shall be completed as per the Drawings and Specification.

26 05 19 Low Voltage Electrical Power Conductors and cables

All items hereunder to be of type, kind, number of cores, armoring and sheathings,

method of fixing , specified codes of practice, etc. as per the Drawings and Specification).

Notwithstanding the Provisions of the method of measurement, cables have been

itemised and referenced to the circuit. The contractor is to make due reference to

drawings nrs E000, E001, E002, E003, ELV201, EL201, EP201, LP201, PS301, PS302, E401,

E402 and E403 for full details and is to allow for all cabling, junctions, flexible

connections, feeder units etc. required to complete the installation in accordance with

the drawings and Specification. No claim for want or lack of knowledge will be

entertained

Page 290: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1 Lighting circuits Item 1

2 Power circuits Item 1

3 Fire alarm circuits Item 1

4 Cooker circuits Item 1

5 Water heater circuits Item 1

6 Fan circuits Item 1

7 Outdoor lighting circuits Item 1

8 HVAC control circuits Item 1

9 Emergency lighting circuits Item 1

10 Lift power circuits Item 1

11 Lightning protection Item 1

Page 291: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

26 05 26 Grounding and Bonding for Electrical Systems

All items hereunder to be described with information such as type, kind, number of

cores, armoring and sheathings, method of fixing , specified codes of practice, etc. as per

the Drawings and Specification).

1 Grounding system Item 1

26 05 33.13 Conduit for Electrical Systems

All items hereunder to be described with information such as type, kind, , method of

fixing , specified codes of practice, etc. as per the Drawings and Specification).

Notwithstanding the Provisions of the method of measurement, conduits have been

itemised and referenced to the circuit. The contractor is to make due reference to

drawings nrs E000, E001, E002, E003, ELV201, EL201, EP201, LP201, PS301, PS302, E401,

E402 and E403 for full details and is to allow for all cabling, junctions, flexible

connections, feeder units etc. required to complete the installation in accordance with

the drawings and Specification. No claim for want or lack of knowledge will be

entertained

2 Lighting circuits Item 1

3 Power circuits Item 1

4 Fire alarm circuits Item 1

5 Cooker circuits Item 1

6 Water heater circuits Item 1

7 Fan circuits Item 1

8 Outdoor lighting circuits Item 1

9 HVAC control circuits Item 1

10 Emergency lighting circuits Item 1

11 Lift power circuits Item 1

12 Lightning protection Item 1

Page 292: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

26 05 36 Cable Trays for Electrical Systems

All items hereunder to be of type, kind, method of fixing , specified codes of practice,

etc. as per the Drawings and Specification).

Notwithstanding the Provisions of the method of measurement, cables trays have been

itemised. The contractor is to make due reference to drawings nrs E000, E001, E002,

E003, ELV201, EL201, EP201, LP201, PS301, PS302, E401, E402 and E403 for full details

and is to allow for complete cable trays for electrical systems, junctions, connections,

etc. required to complete the installation in accordance with the drawings and

Specification. No claim for want or lack of knowledge will be entertained

2 Cable trays for electrical system Item 1

3 Cable ladders for electrical system Item 1

26 24 13 Switchboards

4 All items hereunder to be described with information such as type, kind, rated capacity,

method of fixing, cores reference to Specification, fuses, background, specified codes of

practice, etc. as per the Drawings and Specification).

Page 293: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

26 24 16 Panel boards

All items hereunder to be described with information such as type, kind, rated capacity,

method of fixing, cores reference to Specification, fuses, codes of practice, etc. as per

the Drawings and Specification).

5 Sub-main distribution boards Item 1

26 27 13 Electricity Metering

6 All items hereunder to be described with information such as type, kind, rated capacity, Item 1

method of fixing, cores reference to Specification, fuses, codes of practice, etc. as per

the Drawings and Specification).

Switches & Push Buttons

All items hereunder to be described with information such as appropriate to the

procurement , type, kind, quality, size, method of fixing , specified codes of practice, etc.

as per the Drawings and Specification).

1 One way one gang switch nr 57

2 One way two gang switch nr 18

Power Outlets

3 Single outlet nr 26

4 Double outlet nr 52

5 Double outlet; NEMA 5-18R; weather proof grounding type nr 6

6 Single point shaver outlet nr 12

7 Single point kitchen hood outlet nr 8

8 Floor box finished with three 15A, 230V power outlet, for low current and telecom nr

Page 294: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

socket refer telecom/low current package.

9 Fusible disconnect switch plate, double poles, 32A, 220V, 60HZ, with lamp Indicator for nr 25

water heater

10 Fusible disconnect switch plate, double poles, 32A, 220V, 60HZ, with lamp Indicator for nr 20

air conditioning

11 Fusible disconnect switch plate, double poles, 32A, 220V, 60HZ, with lamp Indicator for nr 8

12 nr 20

13 Fusible disconnect switch plate, double poles, 30A, 220V, 60HZ for exhaust ceiling fan nr 18

14 Fusible disconnect switch plate, double poles, 30A, 220V, 60HZ for wall mounted nr 8

exhaust fan

26 50 00 Lighting

All items hereunder to be described with information such as appropriate to the

procurement , type, kind, quality, size, method of fixing , specified codes of practice, etc.

as per the Drawings and Specification).

1 Luminaire, ceiling mounted, satin steel/nickel/plastic, white diffuser; type B2 nr 12

2 Luminaries, downlight, compact fluorescent lamp with glass cover, 1 x 26W CFL; type D1 nr 55

3 Luminaries, recess mounted downlight, compact fluorescent lamp with glass cover, 1 x nr 24

26W CFL; type D2

4 Luminaire, ceiling mounted, with semi sphere opal bowl diffuser; 1 x 18W, 220V, 60hz; nr 16

type R2

5 Luminaire, power light, steel/chrome/plastic, white, 1 x 50W; type S2 nr 48

6 Luminaire, ceiling mounted, square shaped, 4 x 50W; type S3 nr 12

7 Luminaire, wall mounted 1 x 26W CFL with glass cover; type W1 nr 2

refrigerator (NORMAL SOCKET OUTLET AS PER Q&A # 539)

Fusible disconnect switch plate, double poles, 30A, 220V, 60HZ for TV (NORMAL SOCKET OUTLET AS PER Q&A # 539)

Page 295: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

8 Luminaire, wall mounted fluorescent, steel chrome/plastic, white 2 x 26W; type W2 nr 18

9 Luminaire, up/down wall mounted; 1 x 26W CDL; type W3 nr 7

10 Luminaire, wall mounted CDL; 1 x 26W with aluminum dome reflector; type W4 nr 12

11 Luminaire, wall mounted satin nickel/plastic, white; 1 x 18W CDL; type W5 nr 8

12 Luminaire, self contained exit light with directional arrow nr 4

26 00 00 - Electrical

Additional Items

1 Marking the position of holes, mortices and chases in the structure Item 1

2 Identification; plates, discs, labels, tapes, bands, arrows, symbols, letters, numbers and Item 1

charts; as stated on drawings and in Specification

3 Testing and commissioning of entire installation Item 1

4 Preparation of as-built drawings Item 1

5 Preparation of operation and maintenance manuals Item 1

6 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

6.01 Item 1

Total for ELECTRICAL

CARRIED TO SUMMARY

Telecommunication / Low Current

STRUCTURED CABLING SYSTEM

Supply, Install, Test, connect and commission inclusive of all cabling, conduits and

containment, socket outlets, all in accordance with the relevant service provider

regulations , rules, recommendation and requirements and in accordance with the

specifications and drawings.

1 Information Outlet, Flush Type 1 DATA,1 Telephone 0.3 Meters A.F.F.L. nr 20

Power supply cables from Electric meters to Distribution boards ( as per O&A 537)

Page 296: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2 Telephone Outlet, Wail Mounted flush Type, MTD 0.30m A.F.F.L nr 12

3 Telephone Outlet, Wall Mounted, Flush Type 1.2 Metem A.F.F.L. nr 8

4 TV outlet, wall mounted nr 20

5 9U Telecom Cabinet, Wall Mounted nr 8

6 Optical Distribution box nr 1

7 Set Top Box nr 20

8 LED TV nr 20

9 CAT 6A, UTP Cable m 660

10 Single Mode Fiber Optic Cable -1 x 24 Core m 50

Video Entry System / Intercom

Supply, Install, Test, connect and commission inclusive of all cabling, conduits and

containment, socket outlets, all in accordance with the relevant service provider

regulations, rules, recommendation and requirements and in accordance with the

specifications and drawings.

1 Main Entrance Station nr 1

2 Residential Main Station / Intercom Outlet nr 8

3 CAT 6A, UTP Cable m 90

Consumption Metering

Supply, Install, Test, connect and commission inclusive of all cabling, conduits and

containment, socket outlets, all in accordance with the relevant service provider

regulations , rules, recommendation and requirements and in accordance with the

specifications and drawings.

4 Metering Receiver nr 1

Page 297: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

5 M-bus Cable, 2 x 18AWG m 55

Fire Alarm System

Supply, install, connection, testing and commissioning of wiring and equipment for Fire

Alarm System including all necessary materials and accessories to reflect complete

system installation.

6 Addressable, smoke detector nr 14

7 Addressable, smoke detector with sound base nr 10

8 Addressable, heat detector nr 11

9 Addressable, Manual Pull Station nr 11

10 Fire Alarm Horn With Strobe nr 11

11 Fault Isolator nr 4

12 Control Module nr 4

13 Fire Alarm Control Panel nr 1

Fire Alarm System (cont'd)

Page 298: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1 Power Supply Unit, 24v nr 1

2 Loop Cable, 2x1.5mm2 Fire Resistant m 320

3 24V Cable, 2x2.5mm2 fire Resistant m 100

Additional Items

4 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

ADDITIONAL (As per Q&A Log 19, 343)

4.1 Single Mode Fiber Optic Cable - 1 x 2 Core m 144

4.2 ACTIVE COMPONENTS (AS PER Q&A 487) nr 8

Total for ELECTRONIC SAFETY AND SECURITY

CARRIED TO SUMMARY

31 00 00 EARTHWORK

All works herein shall be completed in full compliance with the Drawings nr A-5001,A-

5002,A-5003.A-S000.,A-S005,A-S401and Specification.

31 10 00 Site Clearing

1 Site preparation, clearing site vegetation m2 392

31 23 16 Excavation

2 Excavating top soil for preservation, average depth 150mm. m2 392

3 Excavating pits(17 nr), maximum depth ≤ 2.00m. m3 463

4 Excavating trenches for grade beams, width ≤ 0.3m m3 21

31 23 23 .13 Backfill

5 Filling to excavations, average thickness > 0.25 m, arising from excavated materials, all m3 203

fill shall be compacted to 75% relative density for cohesionless soils as per ASTM

D4254/ASTM D4293 or 95% maximum density as determined by ASTM D698 for

cohesive material, as per the Drawings and Specifications

Page 299: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

31 23 23.23 Compaction

6 Surface treatments, compacting bottom of excavation, compaction to meet 85% of m2 638

relative density for cohesion-less soils or 95% maximum density as determined by ASTM

D1557 for cohesive materials perthe Drawings and 5pecifications)

31 23 16.26 Rock Removal

7 Disposal of excavated material, off site as stated in the Specification. m3 339

31 31 16 Termite Control

1 Termite control for the horizontal surface (method and type of treatment as per the m2 638

Drawings and Specifications)

2 Termite control for vertical surface (method and type of treatment as per the Drawings m2 676

and Specifications)

Additional Items

3 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Total for EARTHWORK

CARRIED TO SUMMARY

03 00 00 Concrete

04 00 00 Masonry

05 00 00 Metal

06 00 00 Wood, Plastics and Composites

07 00 00 Thermal and Moisture Protection

Page 300: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

08 00 00 Openings

09 00 00 Finishes

10 00 00 Specialties

11 00 00 Equipment

12 00 00 Furnishing

14 00 00 Conveying Equipment

21 00 00 Fire Suppression

22 00 00 Plumbing

23 00 00 Heating, Ventilating and Air Conditioning (HVAC)

26 00 00 Electrical

27 00 00 Communications

31 00 00 Earthwork

SUBTOTAL

MULTIPLY BY 48 BLOCKS 48

Page 301: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

TOTAL FOR APARTMENT TYPE A3 TO SUMMARY

Page 302: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

RATE Amount

164.00 5,904.00

380.00 31,160.00

655.00 2,620.00

296.00 15,096.00

407161.00 407,161.00

25.00 24,475.00

17.00 5,882.00

310.00 2,480.00

17.00 10,761.00

20.00 460.00

7.00 490.00

Page 303: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

506,489.00

US Dollar $. 506,489.00

39.00 3,276.00

55.00 1,485.00

42.00 4,284.00

34.00 13,906.00

35.00 595.00

Page 304: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 23,546.00

US Dollar $. 23,546.00

294.00 4,410.00

113.00 1,356.00

143.00 5,005.00

20.00 1,520.00

283.00 283.00

Page 305: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

US Dollar $. 12,574.00

1750.00 3,500.00

539.00 1,078.00

Page 306: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2147.00 4,294.00

748.00 2,992.00

2217.00 8,868.00

1122.00 6,732.00

Page 307: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

27,464.00

27,464.00

1250.00 2,500.00

401.00 3,208.00

227.00 1,362.00

341.00 1,364.00

781.00 4,686.00

695.00 1,390.00

Page 308: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

14,510.00

14,510.00

261.00 1,566.00

323.00 646.00

576.00 2,304.00

Page 309: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

4,516.00

US Dollar $. 46,490.00

2.00 744.00

5.00 1,140.00

5.00 830.00

18.00 3,978.00

22.00 2,640.00

37.00 12,802.00

3.00 1,038.00

23.00 7,958.00

Page 310: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

514.00 514.00

2966.00 2,966.00

34.00 1,496.00

US Dollar $. 36,106.00

2236.00 2,236.00

1460.00 11,680.00

1012.00 16,192.00

1012.00 16,192.00

Page 311: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

46,300.00

46,300.00

2385.00 7,155.00

1907.00 5,721.00

2711.00 2,711.00

6075.00 12,150.00

5865.00 11,730.00

Page 312: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 39,467.00

BF 39,467.00

9345.00 37,380.00

7574.00 45,444.00

9081.00 18,162.00

7310.00 43,860.00

4410.00 4,410.00

4064.00 4,064.00

Page 313: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 153,320.00

BF 153,320.00

827.00 16,540.00

102.00 816.00

82.00 492.00

134.00 536.00

Page 314: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

18,384.00

18,384.00

US Dollar $ 257,471.00

55.00 1,375.00

22.00 18,392.00

21.00 2,331.00

Page 315: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

22,098.00

22,098.00

55.00 42,130.00

32.00 9,728.00

53.00 7,579.00

72.00 26,784.00

17.00 7,004.00

27.00 1,242.00

27.00 405.00

24.00 1,128.00

20.00 1,060.00

40.00 720.00

Page 316: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

97,780.00

97,780.00

54.00 9,126.00

56.00 2,576.00

56.00 4,032.00

102.00 1,836.00

Page 317: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

11.00 14,520.00

11.00 1,683.00

11.00 5,346.00

11.00 517.00

11.00 3,146.00

42,782.00

US Dollar $. 162,660.00

21.00 378.00

22.00 264.00

0.00 0.00

35.00 420.00

Page 318: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

17.00 204.00

31.00 372.00

54.00 432.00

76.00 608.00

1993.00 19,930.00

22,608.00

22,608.00

816.00 1,632.00

557.00 5,570.00

Page 319: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

875.00 3,500.00

1749.00 6,996.00

17.00 272.00

17,970.00

US Dollar $. 40,578.00

465.00 3,720.00

Page 320: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

US Dollar $. 3,720.00

US Dollar $. 0.00

43439.00 43,439.00

Page 321: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

US Dollar $. 43,439.00

52.00 1,196.00

552.00 552.00

3082.00 9,246.00

Page 322: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

503.00 503.00

96.00 96.00

11,593.00

11,593.00

205.00 205.00

Page 323: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

205.00

US Dollar $. 11,798.00

Page 324: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

20.00 80.00

25.00 900.00

34.00 136.00

48.00 576.00

99.00 198.00

191.00 764.00

19.00 114.00

68.00 136.00

72.00 1,296.00

159.00 318.00

40.00 80.00

45.00 270.00

Included in sanitary fixture, secition 224000

Included in sanitary fixture, secition 224000

Page 325: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

61.00 122.00

1531.00 1,531.00

6,521.00

6,521.00

92.00 2,392.00

62.00 3,224.00

59.00 649.00

49.00 1,078.00

38.00 570.00

26.00 9,490.00

18.00 3,726.00

16.00 3,216.00

29.00 58.00

1576.00 9,456.00

1237.00 2,474.00

46.00 920.00

Page 326: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

96.00 1,920.00

46.00 92.00

179.00 179.00

11.00 286.00

17.00 374.00

29.00 3,045.00

22.00 1,430.00

44,579.00

44,579.00

28.00 112.00

37.00 2,035.00

37.00 4,070.00

Page 327: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

17.00 1,955.00

28.00 280.00

17.00 1,870.00

9.00 945.00

10.00 130.00

Page 328: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

11,397.00

11,397.00

275.00 3,850.00

322.00 3,864.00

192.00 5,568.00

38.00 684.00

313.00 5,634.00

202.00 808.00

171.00 1,539.00

43.00 258.00

As per the drawing it is integrated

with the Acrylic Countertop

41.00 328.00

292.00 3,504.00

Page 329: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

As per Q&A-383, the sink bowl is

integrated with the Acrylic Countertop

166.00 2,988.00

425.00 3,400.00

32,425.00

32,425.00

636.00 5,724.00

11.00 176.00

2841.00 5,682.00

As per Q&A no. 363 this item is Excluded

Page 330: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

458.00 2,748.00

INCLUDED

614.00 614.00

5629.00 5,629.00

INCLUDED

INCLUDED

20,573.00

US Dollar $. 115,495.00

52.00 9,464.00

31.00 8,060.00

Page 331: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

12.00 22,320.00

39,844.00

39,844.00

54.00 756.00

56.00 336.00

58.00 232.00

58.00 464.00

60.00 120.00

62.00 248.00

64.00 128.00

66.00 66.00

64.00 128.00

70.00 140.00

82.00 82.00

74.00 888.00

Page 332: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

87.00 348.00

89.00 356.00

96.00 576.00

included in duct

93.00 744.00

95.00 570.00

96.00 384.00

6,566.00

6,566.00

22.00 88.00

Page 333: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

133.00 1,064.00

160.00 2,880.00

As per Q&A-361 item is deleted

723.00 1,446.00

59.00 118.00

61.00 122.00

61.00 122.00

69.00 138.00

72.00 144.00

80.00 160.00

80.00 160.00

Page 334: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

6,442.00

6,442.00

83.00 166.00

86.00 172.00

86.00 172.00

104.00 208.00

112.00 224.00

43.00 86.00

45.00 90.00

45.00 90.00

50.00 100.00

57.00 114.00

57.00 114.00

64.00 128.00

65.00 130.00

68.00 136.00

70.00 140.00

77.00 154.00

Page 335: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

86.00 172.00

83.00 664.00

42.00 756.00

44.00 352.00

4,168.00

4,168.00

22177.00 22,177.00

Page 336: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2277.00 2,277.00

2680.00 2,680.00

2277.00 2,277.00

2680.00 2,680.00

2277.00 2,277.00

2680.00 2,680.00

2277.00 2,277.00

2680.00 2,680.00

2680.00 2,680.00

2277.00 2,277.00

2277.00 2,277.00

2277.00 2,277.00

2680.00 2,680.00

2277.00 2,277.00

2277.00 2,277.00

2277.00 2,277.00

Page 337: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

61,027.00

61,027.00

2971.00 2,971.00

2277.00 2,277.00

2277.00 2,277.00

2277.00 2,277.00

2971.00 2,971.00

2277.00 2,277.00

2277.00 2,277.00

2277.00 2,277.00

4990.00 4,990.00

2945.00 2,945.00

27,539.00

27,539.00

Page 338: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

INCLUDED

1227.00 1,227.00

INCLUDED

INCLUDED

INCLUDED

15.00 45.00

21.00 21.00

1,293.00

US Dollar $. 146,879.00

Page 339: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

5549.00 5,549.00

5523.00 5,523.00

28.00 28.00

390.00 390.00

1407.00 1,407.00

2543.00 2,543.00

217.00 217.00

2814.00 2,814.00

38.00 38.00

55.00 55.00

As per Q&A # 374 - Not Required

Page 340: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

18,564.00

18,564.00

5899.00 5,899.00

2736.00 2,736.00

2300.00 2,300.00

13.00 13.00

161.00 161.00

578.00 578.00

1044.00 1,044.00

84.00 84.00

1092.00 1,092.00

19.00 19.00

23.00 23.00

As per Q&A # 374 - Not Required

Page 341: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

13,949.00

13,949.00

3394.00 3,394.00

1088.00 1,088.00

Page 342: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

10294.00 10,294.00

16341.00 16,341.00

31,117.00

31,117.00

10.00 570.00

12.00 216.00

9.00 234.00

19.00 988.00

58.00 348.00

92.00 1,104.00

9.00 72.00

Page 343: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

19.00 475.00

19.00 380.00

9.00 72.00

9.00 180.00

19.00 342.00

19.00 152.00

5,133.00

5,133.00

193.00 2,316.00

138.00 7,590.00

110.00 2,640.00

110.00 1,760.00

254.00 12,192.00

659.00 7,908.00

222.00 444.00

Page 344: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

102.00 1,836.00

248.00 1,736.00

222.00 2,664.00

175.00 1,400.00

129.00 516.00

43,002.00

43,002.00

6789.00 6,789.00

US Dollar $. 118,554.00

47.00 940.00

Page 345: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

34.00 408.00

34.00 272.00

34.00 680.00

1255.00 10,040.00

4499.00 4,499.00

10.00 6,600.00

8.00 400.00

23,839.00

23,839.00

1626.00 1,626.00

696.00 5,568.00

11.00 990.00

1084.00 1,084.00

AS PER Q&A # 317 NOT IN THE SCOPE

AS PER Q&A # 317 NOT IN THE SCOPE

Page 346: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

10.00 550.00

68.00 952.00

85.00 850.00

62.00 682.00

68.00 748.00

142.00 1,562.00

76.00 304.00

68.00 272.00

3047.00 3,047.00

18,235.00

18,235.00

Page 347: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

included in the above

10.00 3,200.00

10.00 1,000.00

8.00 1,152.00

2914.00 23,312.00

28,664.00

US Dollar $. 70,738.00

2.00 784.00

3.00 1,176.00

8.00 3,704.00

10.00 210.00

12.00 2,436.00

Page 348: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3.00 1,914.00

4.00 1,356.00

11,580.00

11,580.00

1.00 638.00

1.00 676.00

1,314.00

US Dollar $. 12,894.00

506,489.00

23,546.00

12,574.00

46,490.00

36,106.00

Page 349: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

257,471.00

162,660.00

40,578.00

3,720.00

0.00

43,439.00

11,798.00

115,495.00

146,879.00

118,554.00

70,738.00

12,894.00

1,609,431.00

77,252,688.00

Page 350: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

US Dollar $. 77,252,688.00

Page 351: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Item Nr. Description Unit Qty

03 00 00 - CONCRETE

03 11 13 Structural Cast-in-Place Concrete Forming

1 Plain concrete 20MPa for blinding thickness 100mm for footing and 50mm under slab on grade m3 38

03 31 00 Structural Concrete

2 Reinforced concrete 35Mpa for strip footing m3 87

3 Reinforced concrete for sub structure for elevator pit m3 4

4 Reinforce concrete 35MPa for slab on grade with 7Ø8 / Liner meter thickness 150mm m3 51

5 Precost for super structure item 1

Concrete Topping

6 Structural screed will wiremesh 50mm thick for floor above hollow core slab m2 1023

7 Sand cement foam concrete on roof avarage 75mm thick m2 362

8 Concrete Pads m2 8

9 Sand cement screed for floors to receive finishing 50mm thick m2 661

03 30 53 - Miscellaneous Cast-in-situ Concrete

10 300mm wide x 200mm high reinforced concrete 35 Mpa for lintel m 23

11 100mm wide x 200mm thick reinforced concrete 35 Mpa for lintel m 67

12 200mm wide x 200mm thick reinforced concrete 35 Mpa for lintel m 17

Total for CONCRETE

CARRIED TO SUMMARY

04 00 00 - Masonry

Page 352: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

04 22 00 - Concrete Unit Masonry

Internal walls and Partitions

1 200mm thick CMU wall , 1 hour fire rated, m2 10

2 200mm thick CMU wall , 2 hour fire rated, m2 69

3 100mm thick CMU wall 2hr fire rated at shafts, m2 164

4 100mm thick CMU wall non fire rated m2 423

5 200mm thick 300mm high parapet CMU parapet wall at ground floor, non fire rated m2 17

Total for MASONRY

CARRIED TO SUMMARY

05 00 00 METALS

All metalworks herein shall be completed in full compliance with the Drawings A0-A401,

A0-A402, A0-A403 and Specification.

05 70 00 Decorative Metal

1 Supply and fix 50mm diameter stainless steel hand rails including but not limited to m 15

12mm diameter stainless steel balustrade, 40mm square stainless steel post with 50mm

x 120mm base plate, for staircase, floor mounted, kind, quality, fittings, fixtures,

accessories as shown on Drawing nr A0-A402 and as per Specification.

2 Supply and fix 50mm diameter stainless steel hand rails for staircase, wall mounted, m 13

kind, quality, fittings, fixtures, accessories as shown on Drawing nr A0-A402 and as per

Specification.

3 Supply and fix aluminum powder coated hand rails for balconies, floor mounted, kind, m 34

quality, fittings, fixtures, accessories as shown on Drawings nr A4-A502 and as per

Specification.

4 Supply and fix anti slip nosing strip for staircase, kind, quality, fittings, accessories as m 86

shown on Drawing nr A0-A402 and as per Specification.

05 00 00 Metals

Additional Items

5 The Contractor is to list here and price any items shown on the Drawings, mentioned in

Page 353: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

As per Question and Answer No (65)

5.1 nr 1

Total for METALS

CARRIED TO SUMMARY

06 00 00 WOOD, PLASTICS, AND COMPOSITES

06 41 00 Architectural Wood Casework

As per Question and Answer No. (89) the kitchen cabinet changed to Aluminum

1 Supply and fix kitchen under counter cabinets (2300mm + 1000mm) long 600mm wide nr 6

(counter tops measured separately) at kitchen with wall cabinet MDF melamine

laminated with aluminum edge, base cabinets with polished chrome cabinet pull

handles and all other accessories as per the Drawing nr A0-A904 and Specification

2 Supply and fix kitchen under counter cabinets (1300mm + 1050mm) long 600mm wide nr 6

(counter tops measured separately) at kitchen with wall cabinet MDF melamine

laminated with aluminum edge, base cabinets with polished chrome cabinet pull

handles and all other accessories as per the Drawing nr A0-A904 and Specification

3 Supply and fix kitchen under counter cabinets 600mm long 600mm wide (counter tops nr 6

measured separately) at kitchen with wall cabinet MDF melamine laminated with

aluminum edge, base cabinets with polished chrome cabinet pull handles and all other

accessories as per the Drawing nr A0-A904 and Specification.

4 Supply and fix kitchen overhead counter cabinets (2650 + 2900) mm long 300mm wide nr 6

(counter tops measured separately) at kitchen with wall cabinet MDF melamine

laminated with aluminum edge, overhead cabinets with polished chrome cabinet pull

handles and all other accessories as per the Drawing nr A0-A904 and Specification

06 61 16 Solid Surfacing Fabrications

5 Supply and fix solid acrylic counter top shaped 1450 long 600mm wide with opening for nr 6

wash basin as shown in the Drawing nr A0-A904 and Specification.

6 Supply and fix solid acrylic counter top shaped 700 long 550mm wide with opening for nr 6

wash basin as shown in the Drawing nr A904 and Specification.

7 Supply and fix solid acrylic counter top shaped 850 long 550mm wide with opening for nr 6

wash basin as shown in the Drawing nr A904 and Specification.

Galvanized steel ladder size 350mm x 24500mm high @ elevator pit as shown in dwg No. (A4-A701)

Page 354: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

WOOD, PLASTICS, AND COMPOSITES (Cont'd)

1 Supply and fix Solid Acrylic counter top shaped (2300mm+1000mm) long 600mm depth nr 6

with opening for double bowl kitchen sink including 100mm up stand for counter top as

shown in the Drawing nr A0-A904 and Specification.

2 Supply and fix Solid Acrylic counter top shaped (1300mm+1050mm) long 600mm wide nr 6

with 100mm up stand for counter top as shown in the Drawing nr A0-A904 and

Specification.

3 Supply and fix Solid Acrylic counter top shaped 600mm long 600mm wide with 100mm nr 6

up stand for counter top as shown in the Drawing nr A0-A904 and Specification

06 00 00 Wood, Plastics, and Composites

Additional Items

Page 355: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

4 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Total for WOOD, PLASTICS, AND COMPOSITES

CARRIED TO SUMMARY

07 00 00 THERMAL AND MOISTURE PROTECTION

1 Waterproofing works for substructure with vapour barrier 250 microns, horizontal m2 387

2 Two coats of bitumen paint for sub structure including elevator pit walls for vertical surface. m2 276

3 Ditto for horizontal surface m2 196

Wet Area Waterproofing

4 Waterproofing works for wet area, vertical surface, m2 230

5 Ditto for , horizontal surface, m2 130

Roof Waterproofing

6 m2 348

7 Geotextile layer for roof and balcony water proofing works, horizontal surface, m2 348

as per the Drawings and Specification)

8 100mm thick insulation for water proofing works at roof and balcony water proofing m2 348

works, horizontal surface, per the Drawings and Specification)

Waterproofing membrane for roof and balcony, horizontal surface, as per the Drawings and Specification

Page 356: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Roof Hatches

9 Roof Hatch nr 1

10 Smoke Vent nr 1

11 Anti-vibration insulation m2 28

Total for THERMAL AND MOISTURE PROTECTION

CARRIED TO SUMMARY

08 00 00 OPENINGS

All works herein shall be completed in full compliance with the Doors & Windows Note

Schedule Drawings A0-A801, A0-A802, A0-A803 and Specification.

Note: Notwithstanding the Provisions of the Standard Method of Measurement, door

sets including doors, frames, vision panels, decoration and ironmongery have been

measured as a composite item and the Contractor should make due reference to the

drawings and specification. No claim for lack or want of knowledge will be entertained

08 11 16 Aluminum Doors and Frames

1 Supply and fix aluminum door with fixed double glazed panel, 1600mm wide x 2700mm nr 1

high with 6mm low glass +16+6mm clear glass vision panel including frame, type D4,

finished with and including paint, all accessories and hardware including but not limited

to hinges HDH type, outside and inside door lock, lever handles and latch, wall stop,

roses, weather stripping and escutcheons as stated on the drawings and in in the

Specification.

08 14 00 - Wood Doors

As per Q&A no. 380

2 Supply and fix wooden flush teak veneer door, 54mm thick, 1000mm wide x nr 6

2200mm high including frame, type D1,30 minutes fire rated, finished with and including

paint, all accessories and hardware including but not limited to hinges BBS type, outside

door lock, lever handles and latch, wall stop, roses and escutcheons as stated on the

drawings and in the Specification.

3 Supply and fix wooden flush teak veneer door, 44mm thick, 900mm wide x nr 18

2200mm high including frame, type D2, finished with and including paint, all accessories

and hardware including but not limited to hinges BBS type, outside door lock, lever

handles and latch, wall stop, roses and escutcheons as stated on the drawings and in the

Page 357: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Specification.

4 Supply and fix wooden flush door, 44mm thick, 800mm wide x 2200mm high including nr 18

frame, type D3, finished with and including paint, all accessories and hardware including

but not limited to hinges BBS type, outside door lock, lever handles and latch, wall stop,

roses and escutcheons as stated on the drawings in the Specification.

OPENINGS(Confd)

1 Supply and fix wooden flush teak veneer door, 54mm thick, 1000mm wide x nr 3

2200mm high with 6mm low glass +16+6mm clear glass vision panel 200mm s 900mm

including frame, type 05,30 minutes fire rated, finished with and including paint, all

accessories and hardware including but not limited to hinges BB5 type, outside door

lack, lever handles and latch, wall stop, roses and escutcheons as statedon the drawings

and in the Specification.

2 Supply and fix wooden flush teak veneer door, 54mm thick, 1000mm wide x nr 3

2200mm high including frame, type D6,30 minutes fire rated, finished with and Including

paint, all accessories and hardware including but not limited to hinges BB5 type, outside

door lock, lever handles and latch, wall stop, roses and escutcheons as stated on the

drawings and in the Specification.

3 Supply and fix wooden flush teak veneer door, 54mm thick, 1000mm wide x nr 1

2200mm high with 6mm low glass +16+6mm clear glass vision panel 200mm x 900mm

including frame, type D7,30 minutes fire rated, finished with and including paint, all

accessories and hardware including but not limited to hinges BBS type, outside door

lock, lever handles and latch, wail stop, roses and escutcheons as stated on the drawings

and in the Specification.

08 51 13 Aluminum Windows

4 Supply and fix aluminium double glazed window, 3450mm wide x 1925mm high, nr 2

glass panel with open glass door window Including frame, 1725mm wide x 1925mm high

aluminium shutters in front of sliding glass panel, type W5, finished, all accessories and

hardware including but not limited to hinges, handle, lock, weather tight strip etc. as

stated in the Drawings and Specification.

5 Supply and fix aluminium double glazed window, 3300mm wide s 1925mm high, nr 2

glass panel with open glass door window including frame,1650mm wide x 1925mm high

Page 358: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

aluminium shutters in front of sliding glass panel, type W6, finished, all accessories and

hardware including but not limited to hinges, handle, lock, weather tight strip etc. as

stated in the Drawings and Specification.

OPENINGS(Cont'd)

1 Supply and fix aluminium double glazed window, 4000mm wide x 1925mm high, nr 2

glass panel with open glass door window including frame, 2000mm wide x 1925mm high

aluminium shutters in front of sliding glass panel, type W7, finished, all accessories and

hardware including but not limited to hinges, handle, lock, weather tight strip etc. as

stated in the Drawings and Specification.

2 Supply and fix aluminium double glazed window, 3450mm wide x 3000mm high, nr 4

glass panel with open glass door window including frame,1725mm wide x 3000mm high

aluminium fixed shutters in front of sliding glass panel only type, WS, finished, all accessories and

hardware including but not limited to hinges, handle, lock, weather tight strip etc. as

stated in the Drawings and Specification.

(No glass balustrade is provided, refer to DWG. No. A0-802,A0-803 and A0-901)

3 Supply and fix aluminium double glazed window, 3300mm wide x 3000mm high, nr 4

glass panel with open glass door window including frame, 1650mm wide x 3000mm high

aluminium fixed shutters in front of sliding glass panel only, type W9, finished, all accessories and

hardware including but not limited to hinges, handle, lock, weather tight strip etc. as

stated in the Drawings and Specification.

(No glass balustrade is provided, refer to DWG. No. A0-802,A0-803 and A0-901)

4 Supply and fix aluminium double glazed window, 4000mm wide x 3000mm high, nr 4

glass panel with open glass door window including frame,2000mm wide x 3000mm high

aluminium fixed shutters in front of sliding glass panel only, type W10, finished, all accessories and

hardware including but not limited to hinges, handle, lock, weather tight strip etc. as

stated in the Drawings and Specification.

(No glass balustrade is provided, refer to DWG. No. A0-802,A0-803 and A0-901)

5 Supply and fix aluminium double glazed window, 8300mm wide x 3000mm high, nr 6

glass panel with open glass door window including frame, type, W11, finished, all

accessories and hardware including but not limited to hinges, handle, lock, weather tight

strip etc. as stated in the Drawings and Specification.

Page 359: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

6 Supply and fix aluminium double glazed window, 2550mm wide x 3000mm high, nr 1

glass panel with open glass door window including frame, 2550mm wide x 3000mm h€gh

aluminium shutters in front of sliding glass panel, type W12, finished, all accessories and

hardware including but not limited to hinges, handle, lock, weather tight strip etc. as

stated in the Drawings and Specification.

OPENINGS(Cont'd)

1 Supply and fix aluminium double glazed window, 2550mm wide x 2500mm high, nr 1

glass panel with open glass door window including frame, 2550mm wide x 2500mm high

aluminium shutters in front of sliding glass panel, type W13, finished, all accessories and

hardware including but not limited to hinges, handle, lock, weather tight strip etc. as

stated in the Drawings and Specification.

2 Supply and fix aluminium double glazed window, 650mm wide x 1925mm high, nr 12

glass panel with open glass door window including frame, fixed louvers 650mm wide x

550mm high, type W14, finished, all accessories and hardware including but not limited

to hinges, handle, lock, weather tight strip etc. as stated in the Drawings and

Specification.

08 83 00 Mirrors

3 Supply and fix fixed mirror 1450mm width x 1025mm high for bathrooms (size, kind, nr 6

quality, surface treatment, method of jointing, etc. as per the Drawings nr A0-A902, A0-

A903 and Specification).

4 Supply and fix fixed mirror 700mm width x 1025mm high for bathrooms (size, kind, nr 6

quality, surface treatment, method of jointing, etc. as per the Drawings nr A0-A902, A0-

A903 and Specification).

5 Supply and fix fixed mirror 900mm width x 1025mm high for bathrooms (size, kind, nr 6

quality, surface treatment, method of jointing, etc. as per the Drawings nr A0-A902, A0-

A903 and Specification).

Page 360: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

OPENINGS(Cont'd)

08 00 00 Openings

Additional Items

1 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Total for OPENINGS

CARRIED TO SUMMARY

09 00 00 - FINISHES

09 23 00 Gypsum Board wall

1 Gypsum wall above wooden cabinet closet m2 45

09 24 00 Cement Plastering

2 15mm thick internal Plastering for block walls to receive paint m2 794

3 Plastering for walls to receive tiling at wet areas, m2 207

Page 361: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

FINISHES (Cont'd)

09 30 13 Ceramic Tiling

Floor Tiling

1 Porcelain tile flooring (type - FT1), 600mm x 600mm, m2 875

2 Terrazzo tiles, size 400x400mm at roof m2 304

Wall tiling

3 Mosaic tile (type WT4) 100mm x 300mm size for kitchen walls, m2 150

4 White body wall tile (type WT1) 325mm x 977mm size for toilets and bathroom walls, m2 310

Skirting

5 MDF skirting 100mm height, m 460

.

6 Porcelain skirting 100mm height, for stair case m 42

7 Ditto for Balcony m 12

Stair Finish

8 Porcelain tile tread (type - FT1), 230mm wide x 1350mm length, m 74

9 Porcelain tile for riser (type - FT1), 160mm high x 1350mm length, m 68

Threshold

10 Porcelain tile threshold (type - FT1), 200mm wide x 800mm length, m 18

Page 362: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

FINISHES (Cont'd)

09 50 00 Ceilings

1 Supply and install gypsum ceiling, depth of suspension 500 - 1000 mm m2 120

as per the Drawings nr A4-A906,A0-A821

2 Supply and install Moisture resistant gypsum board ceiling at kitchen m2 54

3 Supply and install Moisture resistant gypsum ceiling for toilets laundary and bathrooms m2 66

09 75 13 Stone Wall Facing

4 Stone slab 400mm wide for parapet walls at ground floor, m 18

09 91 00 - Painting

Wall -Painting

5 Painting for walls, m2 1380

6 Painting for walls in staircases, m2 225

Ceiling -Painting

7 Painting for ceiling m2 500

8 Painting for staircase ceiling m2 60

9 Painting for gypsum board ceiling m2 240

Total for FINISHES

Page 363: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CARRIED TO SUMMARY

` 10 00 00 SPECIALTIES

10 28 00 –Toilet, Bath and Laundry Accessories

Supply & install Plumbing Fixtures as shown in Drawing nr A0-A902, A0-A903 and

Technical Specification including all accessories, fittings , flexible connections etc.

1 Paper towel dispenser (PTD) nr 18

2 Soap dispenser (SD) nr 18

3 Towel ring nr 18

4 Robe hook nr 18

5 Towel bar nr 18

10 44 13.13 Portable Fire Extinguishers

All items hereunder to be described with kind, quality, size, method of fixing , etc. as per

the Drawings and Specification).

7 Supply & install Portable Fire Extinguishers nr 6

8 Supply & install fire blanket nr 6

10 57 00 Wardrobe and Closet Specialties

9 Supply and fix closets 2350 mm Iength, 600mm depth, 2400mm high, type BICO4, with nr 6

MDF laminated dark wood veneer shelves, door with MDF white matt lacquer finish and

chromed stainless steel handles, and all other accessories as per the Drawing nr A0-A932

and Specification.

10 Supply and fix closets 1550 mm length, 600mm depth, 2400mm high, type BIC05, with nr 12

MDF laminated dark wood veneer shelves, door with MDF white matt lauer finish and

chromed stainless steel handles, and all other accessories as per the Drawing nr A0-A932

and Specification.

Page 364: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

SPECIALTIES (Cont'd)

10 22 23 Portable Partitions, Screens, and Panels

1 Supply and fix closets 1100 mm length, 600mm depth, 2400mm high, type BICO6, with nr 6

MDF laminated dark wood veneer shelves, door with MDF white matt lacquer finish and

chromed stainless steel handles, and all other accessories as per the Drawing nr A0-A932

and Specification.

2 Supply and fix closets 750 mm length, 600mm depth, 2400mm high, type BIC07, with nr 6

MDF laminated dark wood veneer shelves, door with MDF white mart lacquer finish and

chromed stainless steel handles, and all other accessories as per the Drawing nr A0-A932

and Specification

3 Supply and fix closets 2125 mm length, 600mm depth, 2400mm high, type BICO3, with nr 6

MDF laminated dark wood veneer shelves, door with MDF white matt lacquer finish and

chromed stainless steel handles, and all other accessories as per the Drawing nr A0-A932

and Specification.

10 22 23 Portable Partitions, Screens, and Panels

4 Supply and fix shower screen 8mm thick tempered glass 900mm x 2000mm high nr 6

partition, finished, all accessories and hardware including but not limited to hinges,

handle, etc. as stated in the Drawing or A0-A904 and Specification.

5 Supply and fix shower screen 8mm thick tempered glass 800mm x 2000mm high nr 6

partition, finished, all accessories and hardware including but not limited to hinges,

handle, etc. as stated in the Drawing nr A0-A904 and Specification.

All Fire suppression works herein shall be completed full incompliance with the Drawings

SPECIALTIES (Cont'd)

10 00 00 Specialties

Additional Items

1 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Page 365: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1.01 Towel Pin nr 12

Total for SPECIALTIES

CARRIED TO SUMMARY

11 00 00 EQUIPMENT

All items hereunder to be described with information such as appropriate to the

procurement , design, supply, execution, type, kind, quality, size, method of fixing ,

specified codes of practice, etc. as per the Drawings and Specification).

11 30 00 Residential Equipment

1 Refrigerator/freezer nr 6

2 Exhaust hoods nr 6

3 Cooker nr 6

4 Washing Machine nr 6

11 00 00 Equipment

Additional Items

5 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Total for EQUIPMENT

CARRIED TO SUMMARY

12 00 00 FURNISHING

Page 366: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

All items hereunder to be described with information such as appropriate to the

procurement , design, supply, execution, type, kind, quality, size, method of fixing ,

specified codes of practice, etc. as per the Drawings and Specification).

12 00 00 Furnishing

Additional Items

1 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Total for FURNISHING

CARRIED TO SUMMARY

14 00 00 - CONVEYING EQUIPMENT

14 10 10 - PASSENGER ELEVATORS

Contractor Designed Elevators

Supply and install 6 person passenger machine room less lift to serve three floors; refer

Specification for performance capacity, weight load, speed of travel, call system etc.; car

to include floor finish to be as per entrance hallway, mirrored and hardwood ceiling with

recessed and emergency lighting, mirrored and hardwood wall finish, chromium plated

handrails, floor indicator, floor push buttons (including braille floor indicators),

emergency call button/alarm, emergency intercom; each floor to have call button and

floor indicator all as manufacturers recommendations

1 Elevator nr 1

Total for CONVEYING EQUIPMENT

CARRIED TO SUMMARY

Page 367: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

21 00 00 FIRE SUPPRESSION

All Fire suppression works herein shall be completed full incompliance with the Drawings

nr A2-MO11, A2-MO12, A2-F201, A2-F202, A2-F203, A2-F204 and Specification.

21 12 00 Fire Suppression Standpipes

Supply & Installation testing and commissioning of steel pipes (painted). All fire fighting

pipes to be completed including but not limited to accessories, fittings, couplings

according to NFPA code/ local civil defense code. Including all kind of supports and

hangers all in accordance to the specificaFons and drawings.

1 Ditto, 65 mm diameter m 23

21 11 19 Fire-Department Connection

2 Fire Connection Department including Non- return Valve, 65mm dia. nr 1

21 12 13 Fire-Suppression Hoses and Nozzles

Fire hose reel cabinet C/W 2-1/2" pressure restricted type landing valve 2-1/2"

svnthetic hose. 1" automatic swinging hose reel, and multipurpose dry powder

extinguisher. The rate also shall be include all set of valves (landing , gate, angle,

PRV,etc-I , Pressure gauges.

3 Fire Hose Cabinet. nr 3

21 12 23 Fire-Suppression Hose Valves

Supply and installation valves complete and all necessary accessories, all in accordance

with the specifications and drawings.

4 Gate Valve , 65mm diameter nr 1

Automatic Air Vent

Supply and Installation of automatic air vent, all in accordance with the specifications

and drawings.

5 65 mm diameter. nr 1

Page 368: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

FIRE SUPPRESSION (Cont'd)

GENERAL

TESTING, ADJUSTING, AND BALANCING OF MEP SYSTEMS

1 Allow for Starting up, pressure testing, complete testing and commissioning for all Fire Item 1

fighting system, including all necessary preparations and attendance for authority

approvals.

2 Allow for drawing, manuals, approvals & instruction books. Item 1

3 Allow for protective and decorative painting Item 1

4 Allow for liaison and coordination with local authorities. Item 1

5 The contractor to list here and price any items shown in the drawings, mentioned in the

specifications or required for the satisfactory completion of this section as per the

relevant authority regulations, but not mentioned here. Any such item not listed is

deemed to be included.

21 00 00 Fire Suppression

Additional Items

6 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

Page 369: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

mentioned here. Any such items not listed below shall be deemed to be included.

Total for FIRE SUPPRESSION

CARRIED TO SUMMARY

22 00 00 - PLUMBING

All items hereunder to be described specified code of practice and regulations, kind,

quality, size, method of fixing , finishes or surface treatments, etc. as per the Drawings

and Specification).

22 05 23 General-Duty Valves for Plumbing Piping

Valves

Valves are classified according to type . Material and/or size . Rates include furnishing

and installing of valves, testing at manufacturer's premises and on site; diameters of

valves and water meter according to pipe diameter which will be connected with it; as

per Drawings and Specification.

Gate Valve

1 25 mm diam. nr 36

2 40 mm diam. nr 12

3 32 mm diam. nr 2

4 63 mm diam. nr 2

5 75 mm diam. nr 4

Angle Valve

6 20 mm diam. nr 63

7 25 mm diam. nr 18

Check Valve

Page 370: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

8 20 mm diam. nr 6

Globe Valve

9 25 mm diam. nr 18

10 40 mm diam. nr 2

Non-Return Valve

11 40 mm diam. nr 6

12 50 mm diam. nr 2

Pressure Reducing Valve

13 75 mm diam. nr 1

22 11 16 Domestic Water Piping

Domestic water piping is classified by material and diameter. Rates include furnishing

and installing of pipes, fittings, accessories, fixing supports, joints, sleeves, special parts,

connections, hanger supports. Rates to include all works and materials necessary for

complete installation for piping system as per the Drawings and Specification.

Water Supply System

1-Cold Water Supply

1 75 mm diameter. m 12

2 63 mm diameter. m 34

Page 371: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3 50 mm diameter. m 11

4 40 mm diameter. m 16

5 32 mm diameter. m 4

6 25 mm diameter. m 350

7 20 mm diameter. m 190

2-Hot Water Supply

8 20 mm diameter. m 195

3 - Accessories

9 Hose Bibb 20mm . nr 3

10 Water Meter 40 mm. nr 6

11 Water Hammer Arrestor nr 16

12 Automatic Air Vent. nr 18

13 Pressure Gauge . nr 2

14 Strainer 75 mm. nr 1

22 13 16 Sanitary Waste and Vent Piping

Sanitary Pipe Works

Sanitary pipe works is classified by material and diameter. Rates include furnishing and

installing of pipes, fittings, accessories, fixing support, joints, sleeves , special parts,

connections, hanger supports. Rates for pipework below ground also include

excavation, backfilling , civil work, trenches and any other accessories or fittings

necessary for complete installation of the piping system. Testing of pipes at the

manufacturer's premises is included. All as per the Drawings and Specification.

Pipes and fitting above ground

Waste Pipe

15 50 mm diameter. m 24

16 75 mm diameter. m 19

Page 372: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

17 110 mm diameter. m 86

Soil Pipe

1 110 mm diameter. m 76

Pipes and fitting below ground

Waste pipe

2 75 mm diameter. m 4

3 110 mm diameter. m 65

Soil Pipe

4 110 mm diameter. m 105

Vent Pipe Works

Vent pipes are classified by material and diameter. Rates include furnishing and installing

of pipes, fittings, accessories, fixing support, joints, sleeves, special parts, connections,

hanger supports. Rates include furnishing and installing of pipes, fittings, accessories,

fixing support, joints, sleeves , special parts, connections, hanger supports. Rates for

pipework below ground also include excavation, backfilling , civil work, trenches and any

other accessories or fittings necessary for complete installation of the piping system.

Testing of pipes at the manufacturer's premises is included. All as per the Drawings and

Specification.

Pipes and fittings above ground

5 75 mm diameter. m 165

Pipes and fitting below ground

6 75 mm diameter. m 3

22 13 19.13 Sanitary Drains

Sanitary drains (to include rainwater pipework and condensate drain pipework) are

classified by material and diameter. Rates include furnishing and installing of pipes,

fittings, accessories, fixing supports, joints, sleeves, special parts, connections, hanger

supports. Rates also include testing of pipes at the manufacturer's premises. All as per

Page 373: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

the Drawings and specification.

Rain water Pipe

7 75 mm diameter. m 85

Condensate Drain Pipe Works

8 20 mm diameter. m 63

9 25 mm diameter. m 54

PLUMBING (Cont'd)

22 33 00 Electric Domestic Water Heaters

Electric domestic water heaters are classified according to capacity. Rates include

furnishing of heater complete with safety valves, air vent, pressure and temperature

relief gauges, drain valves, all valves set (angle, gate, non return, etc. .), thermostat,

heating element, contactors, switch, support, bolts, nuts, connection of pipes, testing on

site, commissioning and putting into service.

1 EWH-A4-01 with (30 litres / 1200 w) capacity. nr 12

2 EWH-A4-02 with (80 litres / 1200 W) capacity, nr 6

3 EWH-A4-03 with (100 litres / 1200 W) capacity. nr 6

22 40 00 Plumbing Fixtures

All items described hereunder to be of kind, quality, size, nature of base, method of

fixing, complete with accessories etc. as per the Drawings nr V1-903 and Specification

Page 374: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

4 Floor Drain (FD) nr 27

5 Flexible Shower Hose(Sprayer ,valve , etc.) nr 18

6 Water Closet nr 18

7 Floor clean out nr 4

8 Roof drain nr 5

9 Vent cap nr 6

10 Bath tub (BT) including taps, plug, accessories and fitting. nr 6

11 Wash basin (WB) nr 18

As pwer Q&A no. 358 clothes washer not in contract, only connection

12 Washing machine connections (washing machine not in contract) nr 6

As pwer Q&A no. 360 shower channel to used

13 Shower (SHO) including shower channel, mixer tap, fitting, spray and adjustable bar nr 6

Plumbing Fixtures (cont'd)

1 Kitchen sink nr 6

integrated with the Acrylic Countertop

2 Taps for wash basin including fittings , plugs, valves, connections and waste. nr 18

3 Mixer tap for kitchen sink including fitting, plugs, chrome plated pipes, valves and nr 6

waste

22 00 00 - Plumbing

Additional Items

4 Inspection chamber as per Drawings and Specification; connected directly to nr 6

sewer network.

5 Clean out (CO) nr 10

Page 375: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

6 Roof Water tank as per Specification; rate shall be include supplying and nr 2

installing, all fittings, accessories, valves, pipework, vents etc. as per the Drawings

and Specification

7 Balcony Drain nr 8

8 Gully Trap nr 4

Additional Items

9 Marking the position of holes, mortices and chases in the structure Item 1

10 Identification; plates, discs, labels, tapes, bands, arrows, symbols, letters, numbers and Item 1

charts; as stated on drawings and in Specification

11 Testing and commissioning of entire installation Item 1

12 Preparation of as-built drawings Item 1

13 Preparation of operation and maintenance manuals Item 1

Page 376: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1 The Contractor is to list here and price any items shown on the Drawings, mentioned in Item

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Total for PLUMBING

CARRIED TO SUMMARY

23 00 00 - HEATING, VENTILATING, AND AIR CONDITIONING (HVAC)

All HVAC works shall be completed as per the Drawings and Specification.

23 07 13 Duct Insulations

All items hereunder to be described with in type, kind, quality, thickness, method of

fixing , specified codes of practice, etc. as per the Drawings and Specification).

1 Supply and fix ductwork insulations outdoor for (supply, return, fresh air, exhaust, etc.); m2 195

air duct to include fixing and accessories as per the Drawings and Specification

23 23 00 Refrigerant Piping

Supply and fix refrigerant pipes for FCU from condensing units to indoor installed AC

units including fittings, sleeves and all accessories as per the Drawings and Specification

Page 377: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2 20 mm diameter with max liquid line 10 mm. m 270

23 31 00 HVAC Ducts and Casings

All items hereunder to be described with in type, kind, quality, size, method of fixing ,

specified codes of practice, and method of fixing supports, etc. as per the Drawings and

Specification).

Notwithstanding the provisions of the Standard Method of Measurement, internal

ductwork is to include insulation to the ductwork. No claim for additional cost due to

lack or want of knowledge will be entertained

3 Supply and fix insulated indoor galvanized steel sheet metal duct work for all HVAC work Kg 1920

as specified and as indicating on drawings, complete with bends, supports, connections,

fittings, splices and all accessories to complete the work.

23 33 13.13 Volume-Control Dampers

All items hereunder to be described with ,type, kind, quality, size, method of fixing ,

specified codes of practice, etc. as per the Drawings and Specification).

Volume Dampers

1 Volume Damper ; 100x100 mm . nr 20

2 Volume Damper ; 150x100 mm . nr 2

3 Volume Damper ; 150x150 mm nr 2

4 Volume Damper ; 150 mm dia. circular damper. nr 6

5 Volume Damper ; 200x150 mm . nr 2

6 Volume Damper ; 200x200 mm . nr 2

7 Volume Damper ; 250x200 mm . nr 2

8 Volume Damper ; 300x300 mm . nr 12

9 Volume Damper ; 350x300 mm . nr 6

Page 378: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

10 Volume Damper ; 350x350 mm . nr 2

11 Volume Damper ; 400x300 mm . nr 6

12 Volume Damper ; 400x350 mm . nr 2

Splitter Dampers

13 Splitter Damper nr 1

23 33 13.16 Fire Dampers

As per Q&A no. 362 the word 'motorized' to be deleted in the description

All items hereunder to be described with information such as type, kind, quality, size,

method of fixing , specified codes of practice, etc. as per the Drawings and Specification).

14 Fire Damper ; Size 100 x 100 mm. nr 6

15 Fire Damper ; Size 150 x 150 mm. nr 6

16 Fire Damper ; Size 200 x 100 mm. nr 6

23 33 46 Flexible Ducts

All items hereunder to be described with in type, kind, quality, size, method of fixing ,

specified codes of practice and method of fixing supports, etc. as per the

Drawings and Specification).

17 Supply and install Flexible duct with insulation ; size diam 150 mm . m 2

23 34 00 HVAC Fans

All items hereunder to be described with information such as appropriate to the

procurement , capacity, design, supply, execution, type, kind, quality, size, method of

Page 379: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

fixing , specified codes of practice, etc. as per the Drawings and Specification).

Supply and install exhaust fan as specified and as indicated in drawing. Fan consists of

casing, fan, motor, control, filter, screen, sand trap louver, all electrical works

(components, wiring, etc.) and all accessories. Electrical power supply 220/1/60.

Wall Mounted

1 Exhaust Fan (EF-01) 100 Pa with total air flow 50 L/S nr 6

Ceiling Mounted

2 Exhaust Fan (EF-02 ) 100 Pa with total air flow 25 L/S . nr 18

Range Hood Fan

3 Range Hood Fan (RH-01) ;150 Pa with total air flow 50 L/S . nr 6

Garbage Exhaust fan

4 Garbage Exhaust fan (GEF-01/GEF-02) ;150 Pa with total air flow 60 L/S . nr 2

23 37 00 Air outlets and Inlets

All items hereunder to be described with information such as type, kind, quality, size,

method of fixing , specified codes of practice, etc. as per the Drawings and Specification).

Supply and install Painted Supply linear bar air Register with complete accessories.as

per the Drawings and Specification.

5 Size 450x200 mm ; 195 L/s . nr 4

6 Size 550x200 mm ; 215 L/s . nr 2

7 Size 550x200 mm ; 235 L/s . nr 4

8 Size 600x200 mm ; 270 L/s . nr 4

9 Size 650x200 mm ; 260 L/s nr 2

10 Size 750x200 mm ; 305 L/s. nr 2

11 Size 850x200 mm ; 345 L/s. nr 4

12 Size 850x250 mm ; 400 L/s. nr 2

13 Size 1050x200 mm ; 440 L/s. nr 4

Page 380: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

14 Size 1050x250 mm ; 520 L/s. nr 2

Supply and install Painted Return linear bar air grille with complete accessories.as per

the Drawings and Specification.

1 Size 450x200 mm ; 195L/s . nr 4

2 Size 550x200 mm 215 L/s . nr 2

3 Size 550x200 mm 235L/s . nr 4

4 Size 600x200 mm ; 270L/s . nr 4

5 Size 550x700 mm ; 260L/s . nr 2

6 Size 750x200 mm ; 305L/s . nr 2

7 Size 850x200 mm; 345L/s . nr 4

8 Size 850x250 mm; 400L/s. nr 2

9 Size 1050x200 mm ; 440L/s . nr 4

10 Size 1050x250 mm ; 520L/s . nr 2

Supply and install 3 way Supply ceiling diffuser with complete accessories.as per the

Drawings and Specification.

11 Size 150X150 mm ; 40 L/s. nr 6

Supply and install exhaust air louver with complete accessories as per the Drawings

and Specification.

Page 381: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

12 Exhaust air louver (150X100)mm . nr 12

13 Exhaust air louver (200X150)mm . nr 6

23 82 00 Convection Heating and Cooling Units

All items hereunder to be described with information such as appropriate to the

procurement , capacity, design, supply, execution, type, kind, quality, size, method of

fixing , specified codes of practice, etc. as per the Drawings and Specification).

Supply and install fresh air handing unit as specified and as indicated in drawing. Unit

to be complete with air cooled condensing unit, fan, pre-filter, bag filter, damper and

sand trap louver with filter, valves, controls, all electrical works (components, wiring ,

etc.) and all accessories. Electrical power supply 380/3/60

14 (FAHU-A4-01) , 760 L / s , 350 Pa ; Total load 30 KW . nr 1

Supply and install concealed fan coil unit as specified and as indicated on drawings.

Unit to be complete with air cooled condensing unit, fan, filter, valves, control,

thermostat, all electrical works (components , wiring , etc. .) and all accessories.

Electrical power supply 220/1/60.

Ground Floor / First Floor

1 FCU-(GFI/1F1A1), 229 L/s, 75Pa; Electricaldata power 1.8KW, nr 2

2 FCU-(GF1/1F1-02) , 189 L/ s, 75 Pa ; Electrical data power 1.8 KW . nr 2

Page 382: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3 FCU-(GF1/1F1-03), 263 L/s, 75Pa; Electricaldata power 1.8KW. nr 2

4 FCU-(GF1/1F1-04), 356 L/ s, 75 Pa ; Electrical data power 2.7 KW . nr 2

5 FCU-(GF1/1F1-05), 470 L/s, 75Pa; Electrical data power 3.6KW. nr 2

6 FCU-(GF2/1F2-01), 229 L/ s , 75 Pa ; Electrical data power 1.8 KW . nr 2

7 FCU-(GF2/1F2-02), 189 L/ s, 75 Pa ; Electrical data power 1.8 KW . nr 2

8 FCU-(GF2/1F2-03) , 263 L/ s, 75 Pa ; Electrical data power 1.8 KW . nr 2

9 FCU-(GF2/1F2-04), 357 L/ s, 75 Pa ; Electrical data power 2.7 KW . nr 2

10 FCU-(GF2/1F2-05), 470 L/s, 75 Pa ; Electrical data power 3.6 KW . nr 2

Second Floor

11 (FCU-LF1-01) , 259 L / s , 75 Pa ; Electrical data power 1.8 KW . nr 1

12 (FCU-LF1-02) , 217 L / s , 75 Pa ; Electrical data power 1.8 KW . nr 1

13 (FCU-LF1-03) , 307 L / s , 75 Pa ; Electrical data power 1.8 KW . nr 1

14 (FCU-LF1-04) , 405 L / s , 75 Pa ; Electrical data power 2.7 KW . nr 1

15 (FCU-LF1-05) , 551 L / s , 75 Pa ; Electrical data power 3.6 KW . nr 1

16 (FCU-LF2-01) , 259 L / s , 75 Pa ; Electrical data power 1.8 KW . nr 1

17 (FCU-LF2-02) , 217 L / s , 75 Pa ; Electrical data power 1.8 KW . nr 1

18 (FCU-LF2-03) , 307 L / s , 75 Pa ; Electrical data power 1.8 KW . nr 1

19 (FCU-LF2-04) , 406 L / s , 75 Pa ; Electrical data power 2.7 KW . nr 1

20 (FCU-LF2-05) , 551 L / s , 75 Pa ; Electrical data power 3.6 KW . nr 1

Page 383: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

HEATING, VENTILATING, AND AIR CONDITIONING (Cont'd)

23 05 93 Testing, Adjusting and Balancing for HVAC

All items hereunder to be described with type of installation, preparatory operations,

stages of test (nr), required attendance, applicable codes etc. as per the Drawings and

Specification).

1 Air balancing of the ducting network Item 1

2 Testing, balancing and commissioning of all the equipment Item 1

Additional Items

3 Marking the position of holes, mortices and chases in the structure Item 1

4 Identification; plates, discs, labels, tapes, bands, arrows, symbols, letters, numbers and Item 1

charts; as stated on drawings and in Specification

5 Testing and commissioning of entire installation Item 1

6 Preparation of as-built drawings Item 1

7 Preparation of operation and maintenance manuals Item 1

8 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

8.01 Exhaust air grille (100X100)mm . nr 3

8.02 Fresh air Grille (250X200)mm . nr 1

Page 384: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for HVAC

CARRIED TO SUMMARY

26 00 00 - ELECTRICAL

All works hereunder shall be completed as per the Drawings and Specification.

26 05 19 Low Voltage Electrical Power Conductors and cables

All items hereunder to be of type, kind, number of cores, armoring and sheathings,

method of fixing , specified codes of practice, etc. as per the Drawings and Specification).

Notwithstanding the Provisions of the method of measurement, cables have been

itemised and referenced to the circuit. The contractor is to make due reference to

drawings nrs E000, E001, E002, E003, ELV201, EL201, EP201, LP201, PS301, PS302, E401,

E402 and E403 for full details and is to allow for all cabling, junctions, flexible

connections, feeder units etc. required to complete the installation in accordance with

the drawings and Specification. No claim for want or lack of knowledge will be

entertained

1 Lighting circuits Item 1

2 Power circuits Item 1

3 Fire alarm circuits Item 1

4 Cooker circuits Item 1

5 Water heater circuits Item 1

6 Fan circuits Item 1

7 Outdoor lighting circuits Item 1

8 HVAC control circuits Item 1

9 Emergency lighting circuits Item 1

10 Lift power circuits Item 1

11 Lightning protection Item 1

Page 385: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

26 05 26 Grounding and Bonding for Electrical Systems

All items hereunder to be described with information such as type, kind, number of

cores, armoring and sheathings, method of fixing , specified codes of practice, etc. as per

the Drawings and Specification).

1 Grounding system Item 1

26 05 33.13 Conduit for Electrical Systems

All items hereunder to be described with information such as type, kind, , method of

fixing , specified codes of practice, etc. as per the Drawings and Specification).

Notwithstanding the Provisions of the method of measurement, conduits have been

itemised and referenced to the circuit. The contractor is to make due reference to

drawings nrs E000, E001, E002, E003, ELV201, EL201, EP201, LP201, PS301, PS302, E401,

E402 and E403 for full details and is to allow for all cabling, junctions, flexible

Page 386: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

connections, feeder units etc. required to complete the installation in accordance with

the drawings and Specification. No claim for want or lack of knowledge will be

entertained

2 Lighting circuits Item 1

3 Power circuits Item 1

4 Fire alarm circuits Item 1

5 Cooker circuits Item 1

6 Water heater circuits Item 1

7 Fan circuits Item 1

8 Outdoor lighting circuits Item 1

9 HVAC control circuits Item 1

10 Emergency lighting circuits Item 1

Page 387: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Conduit for Electrical Systems (cont'd)

1 Lift power circuits Item 1

2 Lightning protection Item 1

26 05 36 Cable Trays for Electrical Systems

All items hereunder to be of type, kind, method of fixing , specified codes of practice,

etc. as per the Drawings and Specification).

Notwithstanding the Provisions of the method of measurement, cables trays have been

itemised. The contractor is to make due reference to drawings nrs E000, E001, E002,

E003, ELV201, EL201, EP201, LP201, PS301, PS302, E401, E402 and E403 for full details

and is to allow for complete cable trays for electrical systems, junctions, connections,

etc. required to complete the installation in accordance with the drawings and

Specification. No claim for want or lack of knowledge will be entertained

3 Cable trays for electrical system Item 1

4 Cable ladders for electrical system Item 1

26 24 13 Switchboards

5 All items hereunder to be described with information such as type, kind, rated capacity,

method of fixing, cores reference to Specification, fuses, background, specified codes of

practice, etc. as per the Drawings and Specification).

26 24 16 Panel boards

All items hereunder to be described with information such as type, kind, rated capacity,

method of fixing, cores reference to Specification, fuses, codes of practice, etc. as per

the Drawings and Specification).

6 Sub-main distribution boards Item 1

26 27 13 Electricity Metering

7 All items hereunder to be described with information such as type, kind, rated capacity, Item 1

method of fixing, cores reference to Specification, fuses, codes of practice, etc. as per

the Drawings and Specification).

Page 388: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

ELECTRICAL (cont'd)

26 27 26 Wiring Devices

Switches & Push Buttons

All items hereunder to be described with information such as appropriate to the

procurement , type, kind, quality, size, method of fixing , specified codes of practice, etc.

as per the Drawings and Specification).

1 One way one gang switch nr 53

2 One way two gang switch nr 20

Power Outlets

3 Single outlet nr 26

4 Double outlet nr 52

5 Double outlet; NEMA 5-18R; weather proof grounding type nr 6

6 Single point shaver outlet nr 12

Page 389: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

7 Single point kitchen hood outlet nr 8

8 Fusible disconnect switch plate, double poles, 32A, 220V, 60HZ, with lamp Indicator for nr 25

water heater

9 Fusible disconnect switch plate, double poles, 32A, 220V, 60HZ, with lamp Indicator for nr 20

air conditioning

10 Fusible disconnect switch plate, double poles, 32A, 220V, 60HZ, with lamp Indicator for nr 8

11 nr 20

12 Fusible disconnect switch plate, double poles, 30A, 220V, 60HZ for exhaust ceiling fan nr 18

13 Fusible disconnect switch plate, double poles, 30A, 220V, 60HZ for wall mounted nr 8

exhaust fan

ELECTRICAL (cont'd)

26 50 00 Lighting

All items hereunder to be described with information such as appropriate to the

procurement , type, kind, quality, size, method of fixing , specified codes of practice, etc.

as per the Drawings and Specification).

1 Luminaire, ceiling mounted, satin steel/nickel/plastic, white diffuser; type B2 nr 12

2 Luminaries, downlight, compact fluorescent lamp with glass cover, 1 x 26W CFL; type D1 nr 55

3 Luminaries, recess mounted downlight, compact fluorescent lamp with glass cover, 1 x nr 24

26W CFL; type D2

4 Luminaire, ceiling mounted, with semi sphere opal bowl diffuser; 1 x 18W, 220V, 60hz; nr 16

type R2

5 Luminaire, power light, steel/chrome/plastic, white, 1 x 50W; type S2 nr 48

refrigerator (NORMAL SOCKET OUTLET AS PER Q&A # 539)

Fusible disconnect switch plate, double poles, 30A, 220V, 60HZ for TV (NORMAL SOCKET OUTLET AS PER Q&A # 539)

Page 390: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

6 Luminaire, ceiling mounted, square shaped, 4 x 50W; type S3 nr 12

7 Luminaire, wall mounted 1 x 26W CFL with glass cover; type W1 nr 2

8 Luminaire, wall mounted fluorescent, steel chrome/plastic, white 2 x 26W; type W2 nr 18

9 Luminaire, up/down wall mounted; 1 x 26W CDL; type W3 nr 7

10 Luminaire, wall mounted CDL; 1 x 26W with aluminum dome reflector; type W4 nr 12

11 Luminaire, wall mounted satin nickel/plastic, white; 1 x 18W CDL; type W5 nr 8

12 Luminaire, self contained exit light with directional arrow nr 4

ELECTRICAL (cont'd)

26 00 00 - Electrical

Additional Items

1 Marking the position of holes, mortices and chases in the structure Item 1

2 Identification; plates, discs, labels, tapes, bands, arrows, symbols, letters, numbers and Item 1

charts; as stated on drawings and in Specification

3 Testing and commissioning of entire installation Item 1

4 Preparation of as-built drawings Item 1

5 Preparation of operation and maintenance manuals Item 1

6 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

6.01 Item 1Power supply cables from Electric meters to Distribution boards ( as per O&A 537)

Page 391: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for ELECTRICAL

CARRIED TO SUMMARY

Telecommunication / Low Current

STRUCTURED CABLING SYSTEM

Supply, Install, Test, connect and commission inclusive of all cabling, conduits and

containment, socket outlets, all in accordance with the relevant service provider

regulations , rules, recommendation and requirements and in accordance with the

specifications and drawings.

1 Information Outlet, Flush Type 1 DATA,1 Telephone 0.3 Meters A.F.F.L. nr 24

2 Telephone Outlet, Wail Mounted flush Type, MTD 0.30m A.F.F.L nr 18

3 Telephone Outlet, Wall Mounted, Flush Type 1.2 Metem A.F.F.L. nr 6

4 TV outlet, wall mounted nr 24

5 9U Telecom Cabinet, Wall Mounted nr 6

6 Optical Distribution box nr 1

7 Set Top Box nr 24

8 LED TV nr 24

9 CAT 6A, UTP Cable m 1050

10 Single Mode Fiber Optic Cable -1 x 24 Core m 85

Video Entry System / Intercom

Supply, Install, Test, connect and commission inclusive of all cabling, conduits and

containment, socket outlets, all in accordance with the relevant service provider

regulations, rules, recommendation and requirements and in accordance with the

specifications and drawings.

Page 392: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

11 Main Entrance Station nr 1

12 Residential Main Station / Intercom Outlet nr 6

13 CAT 6A, UTP Cable m 55

Consumption Metering

Supply, Install, Test, connect and commission inclusive of all cabling, conduits and

containment, socket outlets, all in accordance with the relevant service provider

regulations , rules, recommendation and requirements and in accordance with the

specifications and drawings.

1 Metering Receiver nr 1

2 M-bus Cable, 2 x 18AWG m 55

Fire Alarm System

Supply, install, connection, testing and commissioning of wiring and equipment for Fire

Alarm System including all necessary materials and accessories to reflect complete

Page 393: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

system installation.

3 Addressable, smoke detector nr 16

4 Addressable, smoke detector with sound base nr 18

5 Addressable, heat detector nr 9

6 Addressable, Manual Pull Station nr 9

7 Fire Alarm Horn With Strobe nr 9

8 Fault Isolator nr 4

9 Control Module nr 4

10 Fire Alarm Control Panel nr 1

11 Power Supply Unit, 24v nr

12 Loop Cable, 2x1.5mm2 Fire Resistant m 320

13 24V Cable, 2x2.5mm2 fire Resistant m 140

Additional Items

14 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

ADDITIONAL (As per Q&A Log 19, 343)

14.1 Single Mode Fiber Optic Cable - 1 x 2 Core m 121

14.2 ACTIVE COMPONENTS (AS PER Q&A 487) m 6

Page 394: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for COMMUNICATIONS

CARRIED TO SUMMARY

31 00 00 EARTHWORK

All works herein shall be completed in full compliance with the Drawings nr A-5001,A-

5002,A-5003.A-S000.,A-S005,A-S401and Specification.

31 10 00 Site Clearing

1 Site preparation, clearing site vegetation m2 419

31 23 16 Excavation

2 Excavating top soil for preservation, average depth 150mm. m2 419

3 Excavating pits(17 nr), maximum depth ≤ 2.00m. m3 406

4 Excavating trenches for grade beams, width ≤ 0.3m m3 30

31 23 23 .13 Backfill

5 Filling to excavations, average thickness > 0.25 m, arising from excavated materials, all m3 195

fill shall be compacted to 75% relative density for cohesionless soils as per ASTM

D4254/ASTM D4293 or 95% maximum density as determined by ASTM D698 for

cohesive material, as per the Drawings and Specifications

31 23 23.23 Compaction

6 Surface treatments, compacting bottom of excavation, compaction to meet 85% of m2 633

relative density for cohesion-less soils or 95% maximum density as determined by ASTM

D1557 for cohesive materials perthe Drawings and 5pecifications)

31 23 16.26 Rock Removal

7 Disposal of excavated material, off site as stated in the Specification. m3 303

Page 395: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

31 31 16 Termite Control

1 Termite control for the horizontal surface (method and type of treatment as per the m2 633

Drawings and Specifications)

2 Termite control for vertical surface (method and type of treatment as per the Drawings m2 696

and Specifications)

Additional Items

3 The Contractor is to list here and price any items shown on the Drawings, mentioned in Item

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Total for EARTHWORK

CARRIED TO SUMMARY

03 00 00 Concrete

04 00 00 Masonry

05 00 00 Metal

06 00 00 Wood, Plastics and Composites

07 00 00 Thermal and Moisture Protection

Page 396: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

08 00 00 Openings

09 00 00 Finishes

10 00 00 Specialties

11 00 00 Equipment

12 00 00 Furnishing

14 00 00 Conveying Equipment

21 00 00 Fire Suppression

22 00 00 Plumbing

23 00 00 Heating, Ventilating and Air Conditioning (HVAC)

26 00 00 Electrical

27 00 00 Communications

31 00 00 Earthwork

SUBTOTAL

64MULTIPLY BY 64 BLOCKS

Page 397: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

TOTAL FOR APARTMENT TYPE A4 TO SUMMARY

Page 398: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Rate Amount

164.00 6232.00

380.00 33060.00

656.00 2624.00

296.00 15096.00

415580.00 415580.00

25.00 25575.00

17.00 6154.00

20.00 460.00

7.00 469.00

13.00 221.00

505471.00

Page 399: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

39.00 390.00

55.00 3795.00

42.00 6888.00

34.00 14382.00

35.00 595.00

26050.00

294.00 4410.00

113.00 1469.00

143.00 4862.00

20.00 1720.00

Page 400: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

283.00 283.00

12744.00

3772.00 22632.00

2719.00 16314.00

666.00 3996.00

487.00 2922.00

291.00 1746.00

329.00 1974.00

Page 401: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

49584.00

49584.00

1154.00 6924.00

613.00 3678.00

157.00 942.00

Page 402: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

61128.00

2.00 774.00

5.00 1380.00

5.00 980.00

22.00 5060.00

22.00 2860.00

37.00 12876.00

3.00 1044.00

23.00 8004.00

Page 403: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

514.00 514.00

2966.00 2966.00

34.00 952.00

37410.00

2236.00 2236.00

1460.00 8760.00

1012.00 18216.00

Page 404: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1012.00 18216.00

47428.00

47428.00

1460.00 4380.00

1460.00 4380.00

1460.00 1460.00

4876.00 9752.00

4663.00 9326.00

Page 405: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

29298.00

29298.00

5652.00 11304.00

7549.00 30196.00

7221.00 28884.00

8753.00 35012.00

14619.00 87714.00

Page 406: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

5447.00 5447.00

198557.00

198557.00

4557.00 4557.00

827.00 9924.00

128.00 768.00

82.00 492.00

82.00 492.00

16233.00

Page 407: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

16233.00

291516.00

55.00 2475.00

22.00 17468.00

21.00 4347.00

Page 408: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

24290.00

24290.00

55.00 48125.00

32.00 9728.00

53.00 7950.00

72.00 22320.00

17.00 7820.00

27.00 1134.00

27.00 324.00

24.00 1776.00

20.00 1360.00

40.00 720.00

Page 409: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

101257.00

101257.00

54.00 6480.00

56.00 3024.00

56.00 3696.00

102.00 1836.00

11.00 15180.00

11.00 2475.00

11.00 5500.00

11.00 660.00

11.00 2640.00

41491.00

Page 410: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

167038.00

21.00 378.00

22.00 396.00

35.00 630.00

17.00 306.00

31.00 558.00

54.00 324.00

76.00 456.00

1644.00 9864.00

1084.00 13008.00

25920.00

Page 411: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

25920.00

770.00 4620.00

525.00 3150.00

1486.00 8916.00

527.00 3162.00

504.00 3024.00

22872.00

22872.00

Page 412: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

17.00 204.00

48996.00

465.00 2790.00

2790.00

Page 413: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

43439.00 43439.00

43439.00

Page 414: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

52.00 1196.00

552.00 552.00

3082.00 9246.00

503.00 503.00

96.00 96.00

Page 415: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

11593.00

11593.00

205.00 205.00

Page 416: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

11798.00

25.00 900.00

48.00 576.00

34.00 68.00

99.00 198.00

191.00 764.00

Iincluded in sanitary fixtures secton 224000

Iincluded in sanitary fixtures secton 224000

Page 417: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

19.00 114.00

72.00 1296.00

159.00 318.00

45.00 270.00

61.00 122.00

1531.00 1531.00

6157.00

6157.00

88.00 1056.00

73.00 2482.00

Page 418: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

59.00 649.00

48.00 768.00

38.00 152.00

26.00 9100.00

18.00 3420.00

18.00 3510.00

29.00 87.00

1576.00 9456.00

46.00 736.00

96.00 1728.00

46.00 92.00

179.00 179.00

59.00 1416.00

88.00 1672.00

Page 419: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

29.00 2494.00

38997.00

38997.00

29.00 2204.00

88.00 352.00

29.00 1885.00

29.00 3045.00

88.00 14520.00

88.00 264.00

Page 420: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

88.00 7480.00

18.00 1134.00

26.00 1404.00

32288.00

32288.00

275.00 3300.00

300.00 1800.00

322.00 1932.00

Page 421: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

192.00 5184.00

38.00 684.00

313.00 5634.00

202.00 808.00

171.00 855.00

43.00 258.00

769.00 4614.00

41.00 246.00

292.00 1752.00

27067.00

27067.00

As per Q&A-383, the sink bowl is

integrated with the Acrylic Countertop

166.00 2988.00

425.00 2550.00

636.00 3816.00

11.00 110.00

Page 422: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2841.00 5682.00

458.00 1832.00

INCLUDED

5220.00 5220.00

INCLUDED

INCLUDED

As per Q&A no. 363 this item is Excluded

Page 423: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

22198.00

22198.00

126707.00

52.00 10140.00

Page 424: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

31.00 8370.00

12.00 23040.00

41550.00

41550.00

54.00 1080.00

56.00 112.00

58.00 116.00

58.00 348.00

60.00 120.00

62.00 124.00

64.00 128.00

70.00 840.00

82.00 492.00

Page 425: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

85.00 170.00

74.00 444.00

87.00 174.00

included in duct

93.00 558.00

95.00 570.00

96.00 576.00

22.00 44.00

5896.00

5896.00

Page 426: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

133.00 798.00

160.00 2880.00

As per Q&A-361 item is deleted

723.00 1446.00

59.00 236.00

64.00 128.00

64.00 256.00

69.00 276.00

72.00 144.00

80.00 160.00

86.00 344.00

86.00 172.00

104.00 416.00

Page 427: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

112.00 224.00

7480.00

7480.00

43.00 172.00

50.00 100.00

50.00 200.00

50.00 200.00

57.00 114.00

57.00 114.00

68.00 272.00

70.00 140.00

77.00 308.00

86.00 172.00

83.00 498.00

Page 428: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

42.00 504.00

44.00 264.00

22599.00 22599.00

25657.00

25657.00

2277.00 4554.00

1690.00 3380.00

Page 429: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2277.00 4554.00

2277.00 4554.00

2680.00 5360.00

2277.00 4554.00

1690.00 3380.00

2277.00 4554.00

2277.00 4554.00

2680.00 5360.00

2277.00 2277.00

1690.00 1690.00

2277.00 2277.00

2277.00 2277.00

2971.00 2971.00

2277.00 2277.00

2277.00 2277.00

2277.00 2277.00

2277.00 2277.00

2971.00 2971.00

Page 430: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

68375.00

68375.00

5725.00 5725.00

3681.00 3681.00

614.00 614.00

5220.00 5220.00

15.00 45.00

21.00 21.00

Page 431: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

15306.00

164264.00

5966.00 5966.00

5951.00 5951.00

28.00 28.00

293.00 293.00

1299.00 1299.00

2543.00 2543.00

217.00 217.00

3463.00 3463.00

38.00 38.00

55.00 55.00

As per Q&A # 374 - Not Required

Page 432: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

19853.00

19853.00

5899.00 5899.00

Page 433: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

5966.00 5966.00

5951.00 5951.00

28.00 28.00

293.00 293.00

1299.00 1299.00

2543.00 2543.00

217.00 217.00

3463.00 3463.00

38.00 38.00

Page 434: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

25697.00

25697.00

55.00 55.00

As per Q&A # 374 - Not Required

3394.00 3394.00

1088.00 1088.00

9306.00 9306.00

Page 435: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

13843.00

13843.00

10.00 530.00

12.00 240.00

9.00 234.00

19.00 988.00

58.00 348.00

92.00 1104.00

Page 436: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

9.00 72.00

19.00 475.00

19.00 380.00

19.00 152.00

9.00 180.00

19.00 342.00

19.00 152.00

5197.00

5197.00

193.00 2316.00

138.00 7590.00

110.00 2640.00

110.00 1760.00

254.00 12192.00

Page 437: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

659.00 7908.00

222.00 444.00

102.00 1836.00

248.00 1736.00

222.00 2664.00

175.00 1400.00

129.00 516.00

43002.00

43002.00

614.00 614.00

5220.00 5220.00

5410.00 5410.00

Page 438: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

11244.00

118836.00

47.00 1128.00

34.00 612.00

34.00 204.00

34.00 816.00

1255.00 7530.00

4499.00 4499.00

7.00 7350.00

8.00 680.00

AS PER Q&A # 317 NOT IN THE

SCOPE

AS PER Q&A # 317 NOT IN THE

SCOPE

Page 439: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

25.00 25.00

28.00 168.00

7.00 385.00

23397.00

23397.00

1084.00 1084.00

7.00 385.00

Page 440: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

68.00 1088.00

85.00 1530.00

62.00 558.00

68.00 612.00

142.00 1278.00

76.00 304.00

68.00 272.00

3047.00 3047.00

10.00 3200.00

10.00 1400.00

8.00 968.00

2914.00 17484.00

Page 441: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

33210.00

56607.00

2.00 838.00

3.00 1257.00

8.00 3248.00

10.00 300.00

12.00 2340.00

3.00 1899.00

4.00 1212.00

Page 442: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

11094.00

11094.00

1.00 633.00

0.00 0.00

11727.00

505471.00

26050.00

12744.00

61128.00

37410.00

Page 443: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

291516.00

167038.00

48996.00

2790.00

0.00

43439.00

11798.00

126707.00

164264.00

118836.00

56607.00

11727.00

1686521.00

###

Page 444: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

35416941.00

Page 445: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Item Nr. Description Unit Qty

03 00 00 - CONCRETE

03 11 13 Structural Cast-in-Place Concrete Forming

1 m3 33

03 31 00 Structural Concrete

2 Reinforced concrete 35Mpa for strip footing m3 82

3 Reinforce concrete 35MPa for slab on grade with 7Ø8 / Liner meter thickness 150mm m3 38

Precast Concrete

3 Precast concrete for super structure item 1

Concrete Topping

4 Sand cement concrete screed with wire mesh thick 50mm for floors above m2 823

hollow core slabs.

5 Sand cement foam concrete to slab at roof average 75mm thick m2 246

6 Sealed Concrete for beds at roof thick 350mm m3 3

7 Sand cement screed for floors to receive finishing thickness 50mm m2 577

03 30 53 - Miscellaneous Cast-in-situ Concrete

8 300mm wide x 200mm high reinforced concrete 35 Mpa for lintel m 42

9 100mm wide x 200mm thick reinforced concrete 35 Mpa for lintel m 38

10 200mm wide x 200mm thick reinforced concrete 35 Mpa for lintel m 6

Plain concrete 20MPa for blinding thickness 100mm for footing and 50mm under slab on grade

Page 446: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for CONCRETE

CARRIED TO SUMMARY

04 00 00 - Masonry

04 22 00 - Concrete Unit Masonry

Internal walls and Partitions

1 100mm thick CMU wall non fire rated m2 262

External walls

2 200mm thick 1150mm high parapet CMU parapet wall at ground floor, non fire rated m2 60

3 300mm thick 1150mm high parapet CMU parapet wall at ground floor,non fire rated m2 13

Page 447: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for MASONRY

CARRIED TO SUMMARY

05 00 00 METALS

All metalworks herein shall be completed full incompliance with the Drawings V1-A902

and Specification.

05 12 00 Structural Steel Framing

1 Supply and fix 200mm x 50mm rectangular hollow aluminum powder coated pergola, m2 112

wall mounted, kind, quality, fittings, fixtures, accessories as per Drawings and as per

Specifications.

05 70 00 Decorative Metal

2 Supply and fix 50mm x 50mm galvanized steel powder coated hand rails for staircase, m 45

side mounted to stair slab, kind, quality, fittings, fixtures, accessories as shown on

Drawings and as per Specification.

05 00 000 Metals

Additional Items

3 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Total for METALS

CARRIED TO SUMMARY

06 00 00 WOOD, PLASTICS, AND COMPOSITES

06 41 00 Architectural Wood Casework

As per Question and Answer No. (89) the kitchen cabinet changed to Aluminum

Page 448: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1 Supply and fix kitchen under counter & overhead cabinets (2350mm + 800mm + nr 3

1320mm) long 600mm wide (counter tops measured separately) at kitchen with wall

cabinet MDF melamine laminated with aluminum edge, base & overhead cabinets with

polished chrome cabinet pull handles and all other accessories as per the Drawing nr V1-

A905 and Specification.

2 Supply and fix kitchen under counter & overhead cabinets 784mm long 600mm wide nr 3

(counter tops measured separately) at kitchen with wall cabinet MDF melamine

laminated with aluminum edge, base & overhead cabinets with polished chrome cabinet

pull handles and all other accessories as per the Drawing nr V1-A905 and Specification.

3 Supply and fix kitchen under counter & overhead cabinets 980mm long 600mm wide nr 3

(counter tops measured separately) at kitchen with wall cabinet MDF melamine

laminated with aluminum edge, base & overhead cabinets with polished chrome cabinet

pull handles and all other accessories as per the Drawing nr V1-A905 and Specification.

06 61 16 Solid Surfacing Fabrications

4 Supply and fix solid acrylic counter top shaped 550mm long 330mm wide with opening nr 3

for wash basin as shown in the Drawing nr V1-A903 and Specification.

5 Supply and fix solid acrylic counter top shaped 550mm long 1020mm wide with opening nr 6

for wash basin as shown in the Drawing nr V1-A903 and Specification.

6 Supply and fix solid acrylic counter top shaped 1185mm long 600mm wide with opening nr 3

for wash basin as shown in the Drawing nr V1-A903 and Specification.

7 Supply and fix Solid Acrylic counter top (2350mm + 800mm + 1320mm) long 600mm nr 3

wide with opening for double bowl kitchen sink including waste disposal unit, 100mm up

stand for counter top as shown in the Drawing nr V1-A903 and Specification.

Wood, Plastics, and Composites (Cont'd)

1 Supply and fix solid acrylic counter top 784mm long 600mm wide including 100mm nr 3

upstand for counter top as shown in the Drawing nr V1-A903 and Specification.

2 Supply and fix solid acrylic counter top 980mm long 600mm wide including 100mm up nr 3

stand for counter top as shown in the Drawing nr V1-A903 and Specification.

Additional Items

3 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Page 449: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total

Total for WOOD, PLASTICS, AND COMPOSITES

CARRIED TO SUMMARY

07 00 00 THERMAL AND MOISTURE PROTECTION

07 10 00 Damp proofing and Waterproofing

Substructure Waterproofing

All works herein shall be completed in full incompliance with the Drawings nr V-S002, VS003,

V-S004, V-S005, V-S401 and Specification.

1 Two coats of bitumen paint for sub structure for vertical surface. m2 306

2 Ditto for horizontal surface m2 214

3 Waterproofing works for substructure with vapour barrier 250 microns, horizontal m2 403

surface, as per the Drawings

Wet Area Waterproofing / Roof Waterproofing

All Works herein shall be completed in full incompliance with the drawings nr V1-A202

V1-203, V1-A204, V1-A205, V1-A903, V1-A907 and specification.

4 Waterproofing works for wet area, vertical surface as per the Drawings m2 198

5 Waterproofing works for wet area, horizontal surface,as per the Drawings m2 98

6 Waterproofing membrane for roof and second floor terrace, horizontal surface, m2 249

as per the Drawings

7 Geotextile layer for roof and second floor terrace water proofing works, horizontal m2 249

surface, as per the Drawings

Page 450: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

THERMAL AND MOISTURE PROTECTION (Cont'd)

1 100mm thick insulation for water proofing works at roof and second floor terrace water m2 249

proofing works, horizontal surface,

07 21 13 Board Insulation

2 Anti-vibration insulation, thickness as per the manufacturers requirements at water tank m2 20

bearing at room as per the Drawing nr V-S401 and Specification.

Total for THERMAL AND MOISTURE PROTECTION

CARRIED TO SUMMARY

08 00 00 OPENINGS

All works herein shall be completed in full compliance with the Doors & Windows Note

Schedule Drawings V1-A801, V1-A802, V1-A803 and Specification.

Note: Notwithstanding the Provisions of the Standard Method of Measurement, door

sets including doors, frames, vision panels, decoration and ironmongery have been

measured as a composite item and the Contractor should make due reference to the

drawings and specification. No claim for lack or want of knowledge will be entertained

08 11 00 Metal Doors and Frames

As per Question and Answer No (419 & 420) Delete the word wooden

1 Supply and fix flush door, 54mm thick, 1450mm wide x 2700mm high with 6mm nr 3

low glass +16+6mm clear glass vision panel including frame, type D1, finished with and

including paint, all accessories and hardware including but not limited to hinges HDH

type, outside door lock, lever handles and latch, wall stop with roses and escutcheons as

stated in the Specification.

2 Supply and fix flush door, 54mm thick, 1000mm wide x 2700mm high nr 3

with 6mm low glass +16+6mm clear glass vision panel including frame, type D2, finished

with and including paint all accessories and hardware including but not limited to hinges

HDH type, door stopper, outside door lock, lever handles and latch, wall stop with roses

and escutcheons as stated in the Specification.

08 14 00 - Wood Doors

3 Supply and fix wooden flush veneer door, 44mm thick, 900mm wide x nr 12

2200mm high including frame, type D3, finished with and including paint, all accessories

and hardware including but not limited to hinges BBS type, inside door lock, lever

handles and latch, wall stop with roses and escutcheons as stated in the Specification.

Page 451: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

4 Supply and fix wooden flush door, 44mm thick, 900mm wide x 2200mm high including nr 18

frame, type D4, finished with and including paint, all accessories and hardware including

but not limited to hinges BBS type, inside door lock, lever handles and latch, wall stop

with roses and escutcheons as stated in the Specification.

08 51 00 Aluminum Windows

1 Supply and fix aluminum double glazed window, 3250mm wide x 2700mm high, nr 3

glass panel with open glass door window including frame, type W1, finished, all

accessories and hardware including but not limited to hinges, handle, lock, weather tight

strip etc. as stated in the Drawings and Specification.

2 Supply and fix aluminum double glazed window, 3250mm wide x 2700mm high, nr 3

aluminum sliding shutters 1074mm x 2700mm, in front sliding glass panel including

frame, type W1a, finished, all accessories and hardware including but not limited to

hinges, handle, lock, weather tight strip etc. as stated in the Drawings and Specification.

3 Supply and fix aluminum double glazed window, 2700mm wide x 2700mm high, nr 3

aluminum sliding shutters 1130mm x 2700mm, in front sliding glass panel including

frame, type W2, finished , all accessories and hardware including but not limited to

hinges, handle, lock, weather tight strip etc. as stated in the Drawings and Specification.

4 Supply and fix aluminum double glazed window, 1500mm wide x 2700mm high, nr 6

aluminum sliding shutters 1130mm x 2700mm, in front sliding glass panel including

frame, type W3, finished, all accessories and hardware including but not limited to

hinges, handle, lock, weather tight strip etc. as stated in the Drawings and Specification.

5 Supply and fix aluminum double glazed window, 1500mm wide x 2700mm high including nr 3

frame, type W4, finished, all accessories and hardware including but not limited to

hinges, handle, lock, weather tight strip etc. as stated in the Drawings and Specification.

6 Supply and fix aluminum double glazed window, 1500mm wide x 2700mm high including nr 3

frame, type W5, finished, all accessories and hardware including but not limited to

hinges, handle, lock, weather tight strip etc. as stated in the Drawings and Specification.

7 Supply and fix aluminum double glazed window, 1500mm wide x 2700mm high, nr 9

aluminum swinging shutters 500mm x 2700mm, in front of glass panel, including frame,

type W5a, finished, all accessories and hardware including but not limited to hinges,

handle, lock, weather tight strip etc. as stated in the Drawings and Specification.

Page 452: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

OPENINGS (Cont'd)

08 83 00 Mirrors

1 Supply and fix fixed mirror 650mm width x 1050mm high for bathrooms ( size, kind, nr 3

quality, surface treatment, method of jointing, etc. as per the Drawings nr V1-903 and

Specification).

2 Supply and fix fixed mirror 1000mm width x 1050mm high for bathrooms ( size, kind, nr 6

quality, surface treatment, method of jointing, etc. as per the Drawings nr V1-903 and

Specification).

3 Supply and fix fixed mirror 1025m width x 1100mm high for bathrooms ( size, kind, nr 3

quality, surface treatment, method of jointing, etc. as per the Drawings nr V1-903 and

Specification).

OPENINGS (Cont'd)

08 00 00 Openings

Additional Items

1 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

08 83 00 Mirrors

1.1 Supply and fix Fixed mirror 1045 width x 1100 mm high for bathroom nr 3

1.2 lm 37

1.3 M²

As per Question and Answer No. (544) toughened laminated glass balustrade behind shutter where applicable

As per Question and Answer No. (531) Electrically Operated Sliding Shutter System (OPTIONAL)

Page 453: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

GLASS SCREENSAs per Question and Answer No. (99)

1.4 8mm tempered glass door and partition size 840 x 2400 mm nr 3

1.5 8mm tempered glass door and partition size 900 x 2000 mm nr 3

1.6 8mm tempered glass door and partition size 955 x 2000 mm nr 3

Total for OPENINGS

CARRIED TO SUMMARY

09 00 00 - FINISHES

09 23 00 Gypsum Board wall

1 Gypsum wall above wooden cabinet closet m2 13

09 24 00 Cement Plastering

2 15mm thick internal Plastering for block walls to receive paint m2 260

3 Ditto for walls to receive tiling at wet areas, m2 183

FINISHES (Cont'd)

09 30 13 Ceramic Tiling

Page 454: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Floor Tiling

1 Porcelain tile flooring (type - FT1), size 600mm x 600mm, m2 561

2 Glazed porcelain stoneware tile flooring (type - FT5), size 600mm x 600mm, m2 110

3 Terrazzo (FT9), 400mm x 400mm m2 111

4 Terrazzo tiles size 400x400mm at roof, m2 137

Wall tiling

5 Mosaic tile (type WT4) 100mm x 300mm size for kitchen walls, m2 83

6 White body wall tile (type WT1) 325mm x 977mm size for toilets and bathroom walls, m2 254

FINISHES (Cont'd)

Skirting

As per client Question and Answer No 293, the height for skirting 100mm

1 MDF skirting 100mm height, m 377

2 Porcelain tile skirting 100mm height (type - FT1) for kitchen and laundry area, m 35

3 Terrazzo tile skirting 100mm height, vertical, fixed over cement sand plaster for second m 74

floor balcony

As per Client Q&A no. 63 the skirtimng for stair case to be porcelain

4 Porcelain Skirting 100mm hight for stair case m 59

Stair Finish

5 Porcelain tile tread (type - FT1), 280mm wide x 1100mm length, m 146

6 Porcelain tile for riser (type - FT1), 160mm high x 1100mm length, m 132

As per client Question and Answer No. 63, the balcony floor finish is changed to porcelain tiles FT5

As per client Question and Answer No. 89 wall finish at back of Kitchen Cabinets is Render

As per client Question and Answer No 76, the balcony skirting is changed to porcelain skirting 100mm high

Page 455: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

7 Glazed porcelain stoneware tile for tread (type - FT5), 280mm wide x 1100mm length m 23

steps for exterior stairs, including bullnose,

8 Glazed porcelain stoneware tile for riser (type - FT5), 150mm wide x 1100mm Length m 34

steps for exterior stairs,

9 Glazed porcelain stoneware tile for tread (type - FT5), 280mm wide x 2000mm straight m 12

steps for exterior stairs, including bullnose,

10 Glazed porcelain stoneware tile for riser (type - FT5), 150mm wide x 2000mm straight m 18

steps for exterior stairs,

FINISHES (Cont'd)

09 50 00 Ceilings

1 Supply and install gypsum ceiling, depth of suspension 500 - 1000 mm m2 180

as per the Drawings nr V1-A906,V1-A901

2

m2 27

3

m2 72

09 75 13 Stone Wall Facing

3 Stone cladding for parapet walls at ground floor, m2 142

as per the Drawing no V1-A702, V1-A209

Supply and install gysum celing for kitchen area depth of suspension 500-1000m (thickness of lining and method of fixing system to structure, kind, quality, size, nature of backgrounds, insulation materials etc, as per the drawing nr V1-A905, V1-A901 and specification

Suuply and installation gypsum ceiling for toilets, laundry and baathrooms, depth of suspesion 500-1000 mm (thicness of lining to structure, kind, quality, size, nature of backgrounds, insulation materials etc, as per the drawing nr V1-A905, V1-A901 and specification

Page 456: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

FINISHES (Cont'd)

09 91 00 - Painting

Wall -Painting

1 Painting for internal walls, m2 1122

2 Painting for walls in staircases, m2 339

Ceiling -Painting

3 Painting for ceiling, m2 250

4 Painting for staircase ceiling, m2 91

5 Painting for gypsum board ceiling m2 278

Stone Cladding

6 Stone cladding parapet ground floor area m2 142

Total for FINISHES

CARRIED TO SUMMARY

10 00 00 SPECIALTIES

10 28 00 –Toilet, Bath and Laundry Accessories

Supply & install Plumbing Fixtures as shown in Drawing nr V1-A903 and Technical

Specification including all accessories, fittings , flexible connections etc.

1 Paper towel dispenser (PTD) nr 12

2 Towel ring nr 12

Page 457: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3 Rob hook nr 12

4 Towel Bar nr 9

10 44 13.13 Portable Fire Extinguishers

All items hereunder to be described with , kind, quality, size, method of fixing , etc. as

per the Drawings and Specification).

5 Supply & install Portable Fire Extinguishers nr 3

6 Supply & install fire blanket nr 3

10 57 00 Wardrobe and Closet Specialties

7 Supply and fix wardrobe 1985 mm length, 600mm wide, 2400mm high, with MDF nr 3

laminated dark wood veneer shelves, door with MDF white matt lacquer finish and

chromed stainless steel handles, and all other accessories as per the Drawing nr V1-A905

and Specification.

8 Supply and fix wardrobe 1260 mm length, 600mm wide, 800mm high, with MDF nr 3

laminated dark wood veneer shelves, door with MDF white matt lacquer finish and

chromed stainless steel handles, and all other accessories as per the Drawing nr V1-A905

and Specification.

9 Supply and fix wardrobe 1875 mm length, 600mm wide, 2400mm high, with MDF nr 3

laminated dark wood veneer shelves, door with MDF white matt lacquer finish and

chromed stainless steel handles, and all other accessories as per the Drawing nr V1-A905

and Specification.

10 Supply and fix wardrobe 1895 mm length, 600mm wide, 2400mm high, with MDF nr 3

laminated dark wood veneer shelves, door with MDF white matt lacquer finish and

chromed stainless steel handles, and all other accessories as per the Drawing nr V1-A905

and Specification.

Page 458: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

SPECIALTIES (Cont'd)

1 Supply and fix timber shelves nr 3

10 00 00 Specialties

Additional Items

2 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

2.01 Soap Dish (SD) nr 9

2.02 Towel Pin nr 9

Total for SPECIALTIES

CARRIED TO SUMMARY

11 00 00 EQUIPMENT

All items hereunder to be described with information such as appropriate to the

procurement , design, supply, execution, type, kind, quality, size, method of fixing ,

specified codes of practice, etc. as per the Drawings and Specification).

11 30 00 Residential Equipment

AS PER Q&A-77 NOT INCLUDED

1 Refrigerator/freezer nr 3

2 Exhaust hoods nr 3

AS PER Q&A-77 NOT INCLUDED

3 Cooker nr 3

AS PER Q&A-77 NOT INCLUDED

4 Washing Machine nr 3

Page 459: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

11 00 00 EQUIPMENT

Additional Items

5 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Page 460: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for EQUIPMENT

CARRIED TO SUMMARY

12 00 00 FURNISHING

All items hereunder to be described with information such as appropriate to the

procurement , design, supply, execution, type, kind, quality, size, method of fixing ,

specified codes of practice, etc. as per the Drawings and Specification).

12 00 00 FURNISHING

Additional Items

1 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Page 461: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for FURNISHING

CARRIED TO SUMMARY

22 00 00 - PLUMBING

All items hereunder to be described specified code of practice and regulations, kind,

quality, size, method of fixing , finishes or surface treatments, etc. as per the Drawings

and Specification).

22 05 23 General-Duty Valves for Plumbing Piping

Valves

Valves are classified according to type . Material and/or size . Rates include furnishing

and installing of valves, testing at manufacturer's premises and on site; diameters of

valves and water meter according to pipe diameter which will be connected with it; as

per Drawings and Specification.

Gate Valve

1 20 mm diam. nr 9

2 25 mm diam. nr 24

3 40 mm diam. nr 3

Page 462: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

4 50 mm diam. nr 24

Angle Valve

5 20 mm diam. nr 6

6 25 mm diam. nr 12

Globe Valve

7 20 mm diam. nr 6

8 25 mm diam. nr 15

9 50 mm diam. nr 3

Non-Return Valve

10 20 mm diam. nr 6

11 25 mm diam. nr 12

12 50 mm diam. nr 6

Pressure Reducing Valve

13 50 mm diam. nr 3

22 11 16 Domestic Water Piping

Page 463: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Domestic water piping is classified by material and diameter. Rates include furnishing

and installing of pipes, fittings, accessories, fixing supports, joints, sleeves, special parts,

connections, hanger supports. Rates to include all works and materials necessary for

complete installation for piping system as per the Drawings and Specification.

Water Supply System

1-Cold Water Supply

1 50 mm diameter. m 105

2 40 mm diameter. m 30

3 25 mm diameter. m 210

4 20 mm diameter. m 195

2-Hot Water Supply

5 20 mm diameter. m 165

3 - Accessories

6 Hose Bibb 20mm . nr 6

7 Water Meter 50 mm. nr 3

8 Water Hammer Arrestor nr 21

9 Automatic Air Vent. nr 6

10 Pressure Gauge . nr 6

11 Strainer 50 mm. nr 3

22 13 16 Sanitary Waste and Vent Piping

Sanitary Pipe Works

Sanitary pipe works is classified by material and diameter. Rates include furnishing and

installing of pipes, fittings, accessories, fixing support, joints, sleeves , special parts,

connections, hanger supports. Rates for pipework below ground also include excavation,

backfilling , civil work, trenches and any other accessories or fittings necessary for

complete installation of the piping system. Testing of pipes at the manufacturer's

premises is included. All as per the Drawings and Specification.

Pipes and fitting above ground

Page 464: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Waste Pipe

12 50 mm diameter. m 36

13 75 mm diameter. m 60

14 110 mm diameter. m 81

Soil Pipe

15 110 mm diameter. m 90

PLUMBING (Cont'd)

Pipes and fitting below ground

Waste pipe

1 75 mm diameter. m 24

2 110 mm diameter. m 30

Soil Pipe

3 110 mm diameter. m 54

Vent Pipe Works

Vent pipes are classified by material and diameter. Rates include furnishing and installing

of pipes, fittings, accessories, fixing support, joints, sleeves, special parts, connections,

hanger supports. Rates include furnishing and installing of pipes, fittings, accessories,

fixing support, joints, sleeves , special parts, connections, hanger supports. Rates for

pipework below ground also include excavation, backfilling , civil work, trenches and any

other accessories or fittings necessary for complete installation of the piping system.

Testing of pipes at the manufacturer's premises is included. All as per the Drawings and

Specification.

Pipes and fittings above ground

4 75 mm diameter. m 66

Page 465: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Pipes and fitting below ground

5 75 mm diameter. m 15

22 13 19.13 Sanitary Drains

Sanitary drains (to include rainwater pipework and condensate drain pipework) are

classified by material and diameter. Rates include furnishing and installing of pipes,

fittings, accessories, fixing supports, joints, sleeves, special parts, connections, hanger

supports. Rates also include testing of pipes at the manufacturer's premises. All as per

the Drawings and specification.

Rain water Pipe

6 75 mm diameter. m 75

Condensate Drain Pipe Works

7 20 mm diameter. m 36

8 25 mm diameter. m 21

PLUMBING (Cont'd)

22 33 00 Electric Domestic Water Heaters

Electric domestic water heaters are classified according to capacity. Rates include

furnishing of heater complete with safety valves, air vent, pressure and temperature

relief gauges, drain valves, all valves set (angle, gate, non return, etc. .), thermostat,

heating element, contactors, switch, support, bolts, nuts, connection of pipes, testing on

Page 466: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

site, commissioning and putting into service.

1 EWH-V1-01 with (30 liters / 1200 W) capacity. nr 6

2 EWH-V1-02 with (100 liters / 1500 W) capacity. nr 6

3 EWH-V1-03 with (80 liters / 1200 W) capacity. nr 6

22 40 00 Plumbing Fixtures

All items described hereunder to be of kind, quality, size, nature of base, method of

fixing, complete with accessories etc. as per the Drawings nr V1-903 and Specification

4 Floor Drain (FD) nr 18

5 Flexible Shower Hose(Sprayer ,valve , etc.) nr 12

6 Water Closet nr 12

7 Floor clean out nr 12

8 Roof drain nr 9

9 Vent cap nr 3

10 Bath tub (BT) including taps, plug, accessories and fitting. nr 3

As per the drawing it is integrated

11 Wash basin (WB) nr 12

As pwer Q&A no. 358 clothes washer not in contract, only connection

12 Washing machine connections (washing machine not in contract) nr 3

As pwer Q&A no. 360 shower channel to be used

13 Shower (SHO) including shower channel, mixer tap, fitting, spray and adjustable bar nr 6

As per Q&A-383, the sink bowl is

14 Kitchen sink nr 3

15 Taps for wash basin including fittings , plugs, valves, connections and waste. nr 12

16 Mixer tap for kitchen sink including fitting, plugs, chrome plated pipes, valves and nr 3

waste

Page 467: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

PLUMBING (Cont'd)

22 00 00 - Plumbing

Additional Items

1 Inspection chamber as per Drawings and Specification; connected directly to nr 3

sewer network.

2 Clean out (CO) nr 9

3 Roof Water tank as per Specification; rate shall be include supplying and installing, nr 3

all fittings, accessories, valves, pipework, vents etc. as per the Drawings and

Specification

4 Balcony Drain nr 3

5 Gully Trap nr 3

Additional Items

6 Marking the position of holes, mortices and chases in the structure Item 1

7 Identification; plates, discs, labels, tapes, bands, arrows, symbols, letters, numbers and Item 1

charts; as stated on drawings and in Specification

8 Testing and commissioning of entire installation Item 1

9 Preparation of as-built drawings Item 1

10 Preparation of operation and maintenance manuals Item 1

11 The Contractor is to list here and price any items shown on the Drawings, mentioned in Item

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Page 468: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for PLUMBING

CARRIED TO SUMMARY

23 00 00 - HEATING, VENTILATING, AND AIR CONDITIONING (HVAC)

All HVAC works shall be completed as per the Drawings and Specification.

23 23 00 Refrigerant Piping

Supply and fix refrigerant pipes for FCU from condensing units to indoor installed AC

units including fittings, sleeves and all accessories as per the Drawings and Specification

1 20 mm diameter with max liquid line 10 mm. m 285

Page 469: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

23 31 00 HVAC Ducts and Casings

All items described hereunder to be of type, kind, quality, size, method of fixing, specified

codes of practice, method of fixing/supports, etc. as per the Drawings and Specification

Notwithstanding the provisions of the Standard Method of Measurement, internal Note

ductwork is to include insulation to the ductwork. No claim for additional cost due to lack

or want of knowledge will be entertained

2 Supply and fix insulated indoor galvanized steel sheet metal duct work for all HVAC work Kg 930

as specified and as indicating on drawings, complete with bends, supports, connections,

fittings, splices and all accessories to complete the work.

Page 470: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

HEATING, VENTILATING, AND AIR CONDITIONING (Cont'd)

23 33 13.13 Volume-Control Dampers

All items described hereunder to be of type, kind, quality, size, method of fixing, specified

codes of practice, etc. as per the Drawings and Specification

Volume Dampers

1 Volume Damper ; 200 mm dia. circular damper nr 3

2 Volume Damper ; 300 mm dia. circular damper nr 3

3 Volume Damper ; 900x150 mm nr 6

23 33 46 Flexible Ducts

All items described hereunder to be of type, kind, quality, size, method of fixing, specified

codes of practice, etc. as per the Drawings and Specification

4 Supply and install flexible duct with insulation; size 200 mm dia. m 3

5 Supply and install flexible duct with insulation; size 300 mm dia. m 5

23 34 00 HVAC Fans

All items described hereunder to be of capacity, design, supply, execution, type, kind,

quality, size, method of fixing , specified codes of practice, etc. as per the Drawings and

Specification

Supply and install exhaust fan as specified and as indicated in drawing. Fan consists of

casing, fan, motor, control, filter, sand trap louver, all electrical works (components,

wiring, switches etc.) and all accessories. Electrical power supply 220/1/60.

Wall Mounted

6 Exhaust Fan (EF-01) 40 Pa with total air flow 50 L/S . nr 3

Ceiling Mounted

7 xhaust Fan (EF-02 to EF-07)) 100 Pa with total air flow 25 L/S nr 18

Page 471: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Range Hood Fan

8 Range Hood Fan (RH-01) ;150 Pa with total air flow 50 L/S . nr 3

HEATING, VENTILATING, AND AIR CONDITIONING (Cont'd)

23 37 00 Air outlets and Inlets

All items described hereunder to be of type, kind, quality, size, method of fixing, specified

codes of practice, etc. as per the Drawings and Specification

Supply and install painted supply linear bar air register with complete accessories as per

the Drawings and Specification

1 Size 600x150 mm ; 200 L/s . nr 3

2 Size 800x150 mm ; 235 L/s. nr 3

3 Size 800x150 mm ; 255 L/s. nr 3

4 Size 800x150 mm ; 260 L/s. nr 3

5 Size 900x150 mm ; 330 L/s. nr 3

Page 472: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

6 Size 1000x200 mm ; 510 L/s . nr 3

Supply and install painted return linear bar air grille with complete accessories as per the

Drawings and Specification.

7 Size 600x150 mm ; 200 L/s . nr 3

8 Size 800x150 mm ; 235 L/s. nr 3

9 Size 800x150 mm ; 255 L/s. nr 3

10 Size 800x150 mm ; 260 L/s. nr 3

11 Size 900x150 mm ; 330 L/s. nr 3

12 Size 1000x200 mm ; 510 L/s . nr 3

Supply and install 3 way Supply ceiling diffuser with complete accessories.as per the

Drawings and Specification.

13 Size 375X375 mm ; 100 L/s. nr 3

14 Size 450X450 mm ; 200 L/s. nr 3

Supply and install 4 way return ceiling diffuser with complete accessories as per the

Drawings and Specification.

15 Size 450X450 mm ; 200 L/s. nr 3

Exhaust air louver

16 Exhaust air louver (250X100)mm. nr 9

17 Exhaust air louver (250X150)mm. nr 12

Page 473: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

HEATING, VENTILATING, AND AIR CONDITIONING (Cont'd)

23 82 00 Convection Heating and Cooling Units

All items described hereunder to be of capacity, design, supply, execution, type, kind,

quality, size, method of fixing , specified codes of practice, etc. as per the Drawings and

Specification

Supply and install concealed fan coil unit as specified and as indicated in drawing. Unit to

be complete with air cooled condensing unit, fan, filter, valves, controls, thermostat, all

electrical works (components, wiring, switches etc.) and all accessories. Electrical power

supply 220/1/60.

1 (FCU-01) , 347 L / s , 50 Pa ; Electrical data power 4.5 KW . nr 3

2 (FCU-02) , 530 L / s , 50 Pa ; Electrical data power 4.5 KW . nr 3

3 (FCU-03) , 259 L / s , 50 Pa ; Electrical data power 3 KW . nr 3

4 (FCU-04) , 235 L / s , 50 Pa ; Electrical data power 3 KW nr 3

5 (FCU-05) , 197 L / s , 50 Pa ; Electrical data power 3 KW . nr 3

6 (FCU-06) , 509 L / s , 50 Pa ; Electrical data power 4.5 KW nr 3

23 05 93 Testing, Adjusting and Balancing for HVAC

All items described hereunder to be as required by type of installation, preparatory

operations, stages of test (nr), required attendance, applicable codes etc. as per the

Drawings and Specification).

7 Air balancing of the ducting network Item 1

8 Testing, balancing and commissioning of all the equipment Item 1

HEATING, VENTILATING, AND AIR CONDITIONING (Cont'd)

23 00 00 - Heating, Ventilating, and Air Conditioning (HVAC)

Page 474: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Additional Items

1 Marking the position of holes, mortices and chases in the structure Item 1

2 Identification; plates, discs, labels, tapes, bands, arrows, symbols, letters, numbers and Item 1

charts; as stated on drawings and in Specification

3 Testing and commissioning of entire installation Item 1

4 Preparation of as-built drawings Item 1

5 Preparation of operation and maintenance manuals Item 1

6 The Contractor is to list here and price any items shown on the Drawings, mentioned in Item

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Total for HVAC

CARRIED TO SUMMARY

26 00 00 - ELECTRICAL

Note: the measurement below is for a block of three Villa type A1

All works hereunder shall be completed as per the Drawings and Specification.

26 05 19 Low Voltage Electrical Power Conductors and cables

All items hereunder to be of type, kind, number of cores, armoring and sheathings,

method of fixing , specified codes of practice, etc. as per the Drawings and Specification).

Notwithstanding the Provisions of the method of measurement, cables have been

itemized and referenced to the circuit. The contractor is to make due reference to

drawings nrs E000, E001, E002, E003, EL201, EL202, EP201, EP202, LP201, LP202, LP203,

PS301, PS302 MD401, MD402 and MD403 for full details and is to allow for all cabling,

junctions, flexible connections, feeder units etc. required to complete the installation in

accordance with the drawings and Specification. No claim for want or lack of knowledge

will be entertained

1 Lighting circuits Item 1

2 Power circuits Item 1

Page 475: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3 Fire alarm circuits Item 1

4 Cooker circuits Item 1

5 Water heater circuits Item 1

6 Fan circuits Item 1

7 Outdoor lighting circuits Item 1

8 HVAC control circuits Item 1

ELECTRICAL (Cont'd)

Page 476: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

26 05 26 Grounding and Bonding for Electrical Systems

All items hereunder to be described with information such as type, kind, number of

cores, armoring and sheathings, method of fixing , specified codes of practice, etc. as per

the Drawings and Specification).

1 grounding system Item 1

26 05 33.13 Conduit for Electrical Systems

All items hereunder to be described with information such as type, kind, , method of

fixing , specified codes of practice, etc. as per the Drawings and Specification).

Notwithstanding the Provisions of the method of measurement, conduits have been

itemized and referenced to the circuit. The contractor is to make due reference to

drawings nrs E000, E001, E002, E003, EL201, EL202, EP201, EP202, LP201, LP202, LP203,

PS301, PS302 MD401, MD402 and MD403 for full details and is to allow for all tracking,

fixings, type, size, materials, boxes, connections etc. required to complete the installation

in accordance with the drawings and Specification. No claim for want or lack of

knowledge will be entertained

2 Lighting circuits Item 1

3 Power circuits Item 1

4 Fire alarm circuits Item 1

5 Cooker circuits Item 1

6 Water heater circuits Item 1

7 Fan circuits Item 1

8 Outdoor lighting circuits Item 1

9 HVAC control circuits Item 1

Page 477: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

ELECTRICAL (Cont'd)

26 24 13 Switchboards

1 All items hereunder to be described with information such as type, kind, rated capacity,

method of fixing, cores reference to Specification, fuses, background, specified codes of

practice, etc. as per the Drawings and Specification).

26 24 16 Panel boards

All items hereunder to be described with information such as type, kind, rated capacity,

method of fixing, cores reference to Specification, fuses, background, specified codes of

practice, etc. as per the Drawings and Specification).

2 Distribution and panel boards Item 1

26 27 13 Electricity Metering

3 All items hereunder to be described with information such as type, kind, rated capacity, Item 1

method of fixing, cores reference to Specification, fuses, background, specified codes of

practice, etc. as per the Drawings and Specification).

26 27 26 Wiring Devices

Notwithstanding the Provisions of the Method of Measurement, wiring devices shall Note

include final circuits. No claim for lack or want of knowledge shall be entertained

Switches & Push Buttons

Page 478: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

All items hereunder to be described with information such as appropriate to the

procurement , type, kind, quality, size, method of fixing , specified codes of practice, etc.

as per the Drawings and Specification).

4 One way one gang switch nr 18

ELECTRICAL (Cont'd)

1 One way two gang switch nr 27

2 One way three gang switch nr 9

3 Two way one gang switch nr 9

Power Outlets

4 Single outlet nr 45

5 Double outlet nr 45

6 1 way 20A 2P 230v switch with pilot light nr 18

7 Fusible disconnect switch, double poles, 20A, 230V, with lamp Indicator nr 18

8 Non-fusable disconnect switch, 1 phase nr 18

26 50 00 Lighting

Notwithstanding the Provisions of the Method of Measurement, lighting shall include Note

final circuits. No claim for lack or want of knowledge shall be entertained

All items hereunder to be described with information such as appropriate to the

procurement , type, kind, quality, size, method of fixing , specified codes of practice, etc.

as per the Drawings and Specification).

9 Luminaries, down light, multi-mounting, 1 x 26W CFL; type D1 nr 24

Page 479: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

ELECTRICAL (Cont'd)

1 Luminaries, down light, multi-mounting, 2 x 26W CFL; type D2 nr 42

2 Luminaries, down light, recessed-mounting, 2 x 26W CFL; compact lamp 220V, 60hz; type nr 12

D3

3 Luminaire, ceiling mounted, square shape; 4 x 18W, 220V, 60hz; type B2 nr 15

4 Luminaire, down light square shaped, 1 nr x 18W, 220V, 60hz; type S2 nr 18

5 Luminaire, ceiling mounted, round shaped; 1 x 18W, 220V, 60hz; type R2 nr 24

6 Luminaire, wall mounted, satin steel/nickel/plastic, white; 1 x 13W, 12V; type A1 nr 3

7 Luminaire, wall mounted, satin steel/nickel/plastic, white; 1 x 18W, CPL; type W2 nr 12

8 Luminaire, wall mounted, satin steel/nickel/plastic, white; 1 x 2W, CPL; type W3 nr 42

9 Luminaire, wall mounted, rectangular shape; 1 x 4W CPL, outdoor; type W6 nr 27

10 Luminaire, wall mounted; 1 x 26W CPL, outdoor; type W7 nr 6

11 Luminaire, bollard type including bollard; HPF, HF electronic ballast with opal plain glass nr 6

diffuser; 220V, outdoor; type LS2

Page 480: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

ELECTRICAL (Cont'd)

26 00 00 - Electrical

Additional Items

1 Marking the position of holes, mortices and chases in the structure Item 1

2 Identification; plates, discs, labels, tapes, bands, arrows, symbols, letters, numbers and Item 1

charts; as stated on drawings and in Specification

3 Testing and commissioning of entire installation Item 1

4 Preparation of as-built drawings Item 1

5 Preparation of operation and maintenance manuals Item 1

6 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

6.01 m 36

Total for ELECTRICAL

CARRIED TO SUMMARY

27 00 00 COMMUNICATIONS

4C 50mm² CU/XLPE/PVC+25mm² CU/PVC E (Cable from kWH meter to DB) (As per Q&A # 537)

Page 481: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Note: the measurement below is for a block of three Villa type V1 Note

STRUCTURED CABLING SYSTEM

Supply, Install, Test, connect and commission inclusive of all cabling, conduits and

containment, socket outlets, all in accordance with the relevant service provider regulations ,

rules, recommendation and requirements and in accordance with the specifications and

drawings.

1 Information Outlet, Flush Type 1 DATA, 1 Telephone 0.3 Meters A.F.F.L. nr 18

2 Telephone Outlet, Wall Mounted Flush Type, MTD 0.30m A.F.F.L nr 9

3 Telephone Outlet, Wall Mounted, Flush Type 1.2 Meters A.F.F.L. nr 3

4 TV outlet, wall mounted nr 15

5 9U Telecom Cabinet, Wall Mounted nr 3

6 Set Top Box nr 15

7 LED TV nr 15

8 CAT 6A, UTP Cable m 510

9 Single Mode Fiber Optic Cable - 1 x 4 Core m See Master plan BOQ

Video Entry System / Intercom

Supply, Install, Test, connect and commission inclusive of all cabling, conduits and

containment, socket outlets, all in accordance with the relevant service provider regulations ,

rules, recommendation and requirements and in accordance with the specifications and

Page 482: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

drawings.

1 Entrance Video Door Station nr 3

2 Residential Main Station nr 3

3 Door release 12V m 3

4 Wireless Handset nr 6

5 CAT 6A, UTP Cable m 30

Consumption Metering

Supply, Install, Test, connect and commission inclusive of all cabling, conduits and

containment, socket outlets, all in accordance with the relevant service provider regulations ,

rules, recommendation and requirements and in accordance with the specifications and

drawings.

6 Metering Receiver nr 3

7 M-bus Cable, 2 x 18AWG m 48

Fire Alarm System

Supply, install, connection, testing and commissioning of wiring and equipment for Fire

Alarm System including all necessary materials and accessories to reflect complete system

installation.

8 Addressable, smoke detector nr 18

9 Addressable, heat detector nr 3

10 Multisensor Detector nr 3

11 Addressable, Manual Pull Station nr 3

Fire Alarm System (cont'd)

1 Sounder / Fire Alarm Bell / Horn nr 9

Page 483: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2 Control Module nr 3

3 Fire Alarm Control Panel nr 3

4 Power Supply Unit, 24v nr 3

5 Loop Cable, 2x1.5mm2 Fire Resistant m 210

6 24V Cable, 2x2.5mm2 Fire Resistant m 81

Additional Items

7 Marking the position of holes, mortises and chases in the structure Item 1

8 Identification; plates, discs, labels, tapes, bands, arrows, symbols, letters, numbers and Item 1

charts; as stated on drawings and in Specification

9 Testing and commissioning of entire installation Item 1

10 Preparation of as-built drawings Item 1

11 Preparation of operation and maintenance manuals Item 1

12 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

ADDITIONAL (As per Q&A 487)

1 ACTIVE COMPONENTS (AS PER Q&A 487) DISTRIBUTION CABINET nr 3

Page 484: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for COMMUNICATIONS

CARRIED TO SUMMARY

31 00 00 EARTHWORK

All works herein shall be completed in full compliance with the Drawings nr V-S001,VS002,

V-S003,V-S004,V-S005,V-S401and Specification.

31 10 00 Site Clearing

1 Site preparation, clearing site vegetation m2 447

31 23 16 Excavation

2 Excavating top soil for preservation, average depth 150mm. m2 447

3 Excavating pits(26 nr), maximum depth ≤ 2.00m. m3 365

4 Excavating trenches for grade beams, width ≤ 0.3m m3 17

31 23 23 .13 Backfill

5 Filling to excavations, average thickness > 0.25 m, arising from excavated materials, all fill m3 279

shall be compacted to 75% relative density for cohesion-less soils as per ASTM

D4254/ASTM D4293 or 95% maximum density as determined by ASTM D698 for cohesive

material, as per the Drawings and Specifications).

31 23 23.23 Compaction

6 Surface treatments, compacting bottom of excavation, compaction to meet 85% of m2 548

relative density for cohesion-less soils or 95% maximum density as determined by ASTM

D1557 for cohesive materials per the Drawings and Specifications)

Page 485: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

31 23 16.26 Rock Removal

7 Disposal of excavated material, off site as stated in the Specification. m3 171

31 31 16 Termite Control

1 Termite control for the horizontal surface (method and type of treatment as per the m2 548

Drawings and Specifications)

2 Termite control for vertical surface (method and type of treatment as per the Drawings m2 594

and Specifications)

Additional Items

3 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Total for EARTHWORK

CARRIED TO SUMMARY

03 00 00 Concrete

04 00 00 Masonry

Page 486: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

05 00 00 Metal

06 00 00 Wood, Plastics and Composites

07 00 00 Thermal and Moisture Protection

08 00 00 Openings

09 00 00 Finishes

10 00 00 Specialties

11 00 00 Equipment

12 00 00 Furnishing

22 00 00 Plumbing

23 00 00 Heating, Ventilating and Air Conditioning (HVAC)

26 00 00 Electrical

27 00 00 Communications

31 00 00 Earthwork

SUBTOTAL

MULTIPLY BY 24 BLOCKS 24

Page 487: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

AMOUNT FOR VILLA V1 TO SUMMARY

Page 488: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Rate Amount

164.00 5,412.00

380.00 31,160.00

296.00 11,248.00

524160.00 524,160.00

25.00 20,575.00

17.00 4,182.00

376.00 1,128.00

17.00 9,809.00

32.00 1,344.00

11.00 418.00

21.00 126.00

Page 489: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 609,562.00

BF 609,562.00

US Dollar. 609,562.00

34.00 8,908.00

35.00 2,100.00

78.00 1,014.00

Page 490: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 12,022.00

US Dollar. 12,022.00

163.00 18,256.00

226.00 10,170.00

US Dollar. 28,426.00

Page 491: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

4982.00 14,946.00

904.00 2,712.00

1118.00 3,354.00

199.00 597.00

387.00 2,322.00

417.00 1,251.00

1159.00 3,477.00

CF 28,659.00

BF 28,659.00

152.00 456.00

190.00 570.00

Page 492: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

US Dollar. 29,685.00

5.00 1,530.00

5.00 1,070.00

2.00 806.00

22.00 4,356.00

22.00 2,156.00

37.00 9,213.00

3.00 747.00

CF 19,878.00

BF 19,878.00

Page 493: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

23.00 5,727.00

34.00 680.00

6,407.00

US Dollar. 26,285.00

2641.00 7,923.00

1564.00 4,692.00

953.00 11,436.00

Page 494: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

952.00 17,136.00

CF 41,187.00

BF 41,187.00

5972.00 17,916.00

6856.00 20,568.00

5312.00 15,936.00

3658.00 21,948.00

1547.00 4,641.00

640.00 1,920.00

1371.00 12,339.00

Page 495: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 95,268.00

BF 95,268.00

82.00 246.00

82.00 492.00

97.00 291.00

CF 1,029.00

BF 1,029.00

85.00 255.00

305.00 11,285.00

723.00 0.00

Page 496: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

580.00 1,740.00

796.00 2,388.00

864.00 2,592.00

18,260.00

US Dollar. 155,744.00

44.00 572.00

22.00 5,720.00

21.00 3,843.00

CF 10,135.00

BF 10,135.00

Page 497: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

55.00 30,855.00

24.00 2,640.00

51.00 5,661.00

32.00 4,384.00

53.00 4,399.00

72.00 18,288.00

CF 66,227.00

BF 66,227.00

17.00 6,409.00

19.00 665.00

19.00 1,406.00

19.00 1,121.00

24.00 3,504.00

20.00 2,640.00

Page 498: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

24.00 552.00

18.00 612.00

24.00 288.00

18.00 324.00

CF 17,521.00

BF 17,521.00

54.00 9,720.00

56.00 1,512.00

56.00 4,032.00

142.00 20,164.00

CF 35,428.00

BF 35,428.00

Page 499: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

11.00 12,342.00

11.00 3,729.00

11.00 2,750.00

11.00 1,001.00

11.00 3,058.00

102.00 14,484.00

CF 37,364.00

BF 37,364.00

US Dollar. 166,675.00

21.00 252.00

35.00 420.00

Page 500: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

17.00 204.00

31.00 279.00

54.00 162.00

76.00 228.00

1389.00 4,167.00

294.00 882.00

1311.00 3,933.00

1326.00 3,978.00

Page 501: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 14,505.00

BF 14,505.00

1239.00 3,717.00

22.00 198.00

17.00 153.00

4,068.00

US Dollar. 18,573.00

AS PER Q&A-77 NOT INCLUDED

IN THE SCOPE OF WORKS

465.00 1,395.00

AS PER Q&A-77 NOT INCLUDED

IN THE SCOPE OF WORKS

AS PER Q&A-77 NOT INCLUDED

IN THE SCOPE OF WORKS

Page 502: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836
Page 503: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

US Dollar. 1,395.00

Page 504: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

US Dollar. 0.00

20.00 180.00

25.00 600.00

48.00 144.00

Page 505: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

65.00 1,560.00

included in sanitary fixtures section 224000

included in sanitary fixtures section 224000

68.00 408.00

72.00 1,080.00

232.00 696.00

20.00 120.00

23.00 276.00

61.00 366.00

366.00 1,098.00

CF 6,528.00

BF 6,528.00

Page 506: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

42.00 4,410.00

31.00 930.00

18.00 3,780.00

15.00 2,925.00

16.00 2,640.00

29.00 174.00

1618.00 4,854.00

46.00 966.00

96.00 576.00

46.00 276.00

96.00 288.00

Page 507: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

11.00 396.00

17.00 1,020.00

29.00 2,349.00

29.00 2,610.00

CF 28,194.00

BF 28,194.00

27.00 648.00

36.00 1,080.00

36.00 1,944.00

17.00 1,122.00

Page 508: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

27.00 405.00

17.00 1,275.00

9.00 324.00

10.00 210.00

CF 7,008.00

BF 7,008.00

Page 509: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

275.00 1,650.00

322.00 1,932.00

300.00 1,800.00

192.00 3,456.00

38.00 456.00

313.00 3,756.00

202.00 2,424.00

171.00 1,539.00

43.00 129.00

769.00 2,307.00

As per the drawing it is integrated

with the Acrylic Countertop

41.00 123.00

292.00 1,752.00

As per Q&A-383, the sink bowl is

integrated with the Acrylic Countertop

166.00 1,992.00

425.00 1,275.00

Page 510: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 24,591.00

BF 24,591.00

636.00 1,908.00

11.00 99.00

1526.00 4,578.00

171.00 513.00

458.00 1,374.00

INCLUDED

614.00 614.00

3530.00 3,530.00

INCLUDED

INCLUDED

Page 511: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

12,616.00

US Dollar. 78,937.00

30.00 8,550.00

Page 512: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

12.00 11,160.00

Page 513: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 19,710.00

BF 19,710.00

66.00 198.00

85.00 255.00

88.00 528.00

23.00 69.00

26.00 130.00

133.00 399.00

162.00 2,916.00

Page 514: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

As per Q&A-361 item is deleted

CF 4,495.00

BF 4,495.00

60.00 180.00

74.00 222.00

74.00 222.00

74.00 222.00

78.00 234.00

Page 515: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

104.00 312.00

45.00 135.00

55.00 165.00

55.00 165.00

55.00 165.00

59.00 177.00

77.00 231.00

139.00 417.00

170.00 510.00

76.00 228.00

44.00 396.00

44.00 528.00

CF 4,509.00

Page 516: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

BF 4,509.00

2277.00 6,831.00

2971.00 8,913.00

2277.00 6,831.00

2277.00 6,831.00

1690.00 5,070.00

2680.00 8,040.00

2209.00 2,209.00

2209.00 2,209.00

CF 46,934.00

BF 46,934.00

Page 517: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

INCLUDED

614.00 614.00

INCLUDED

INCLUDED

INCLUDED

US Dollar. 76,262.00

6019.00 6,019.00

2339.00 2,339.00

Page 518: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

71.00 71.00

135.00 135.00

1235.00 1,235.00

967.00 967.00

580.00 580.00

1567.00 1,567.00

CF 12,913.00

BF 12,913.00

Page 519: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

8012.00 8,012.00

4026.00 4,026.00

2077.00 2,077.00

63.00 63.00

94.00 94.00

827.00 827.00

797.00 797.00

499.00 499.00

1040.00 1,040.00

Page 520: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 17,435.00

BF 17,435.00

3455.00 3,455.00

5815.00 5,815.00

Page 521: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

10.00 180.00

CF 9,450.00

BF 9,450.00

12.00 324.00

20.00 180.00

11.00 99.00

9.00 405.00

19.00 855.00

16.00 288.00

16.00 288.00

47.00 846.00

204.00 4,896.00

Page 522: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 8,181.00

BF 8,181.00

208.00 8,736.00

110.00 1,320.00

193.00 2,895.00

189.00 3,402.00

110.00 2,640.00

184.00 552.00

102.00 1,224.00

250.00 10,500.00

616.00 16,632.00

222.00 1,332.00

901.00 5,406.00

Page 523: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 54,639.00

BF 54,639.00

included

included

included

included

included

39.00 1,404.00

US Dollar. 104,022.00

Page 524: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

47.00 846.00

34.00 306.00

34.00 102.00

34.00 510.00

1736.00 5,208.00

AS PER Q&A # 317 NOT IN THE SCOPE

AS PER Q&A # 317 NOT IN THE SCOPE

10.00 5,100.00

See Master plan BOQ

CF 12,072.00

BF 12,072.00

Page 525: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

209.00 627.00

458.00 1,374.00

109.00 327.00

326.00 1,956.00

10.00 300.00

1084.00 3,252.00

10.00 480.00

68.00 1,224.00

62.00 186.00

97.00 291.00

68.00 204.00

CF 10,221.00

BF 10,221.00

80.00 720.00

Page 526: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

68.00 204.00

3047.00 9,141.00

included in the above

12.00 2,520.00

12.00 972.00

included

included

included

included

included

2914.00 8,742.00

Page 527: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

22,299.00

US Dollar. 44,592.00

2.00 894.00

3.00 1,341.00

8.00 2,920.00

10.00 170.00

12.00 3,348.00

3.00 1,644.00

Page 528: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

4.00 684.00

CF 11,001.00

BF 11,001.00

1.00 548.00

0.00 0.00

US Dollar 11,549.00

609,562.00

12,022.00

Page 529: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

28,426.00

29,685.00

26,285.00

155,744.00

166,675.00

18,573.00

1,395.00

0.00

78,937.00

76,262.00

104,022.00

44,592.00

11,549.00

1,363,729.00

###

Page 530: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

US Dollar ###

Page 531: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Item Nr. Description Unit Qty

03 00 00 - CONCRETE

03 11 13 Structural Cast-in-Place Concrete Forming

1 m3 43

03 31 00 Structural Concrete

2 Reinforced concrete 35Mpa for strip footing m3 106

3 Reinforce concrete 35MPa for slab on grade with 7Ø8 / Liner meter thickness 150mm m3 43

Precast Concrete

3 Precast Concrete for super structure item 1

Concrete Topping

4 Sand cement concrete screed with wire mesh thick 50mm for floors above m2 1097

hollow core slabs.

5 Sand cement foam concrete to slab at roof average 75mm thick m2 328

6 Sealed Concrete for beds at roof thick 350mm m3 3

7 Sand cement screed for floors to receive finishing thickness 50mm m2 769

03 30 53 - Miscellaneous Cast-in-situ Concrete

8 300mm wide x 200mm high reinforced concrete 35 Mpa for lintel m 55

9 100mm wide x 200mm thick reinforced concrete 35 Mpa for lintel m 50

10 200mm wide x 200mm thick reinforced concrete 35 Mpa for lintel m 8

Plain concrete 20MPa for blinding thickness 100mm for footing and 50mm under slab on grade

Page 532: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for CONCRETE

CARRIED TO SUMMARY

04 00 00 - Masonry

04 22 00 - Concrete Unit Masonry

Internal walls and Partitions

1 100mm thick CMU wall non fire rated m2 349

External walls

2 200mm thick 1150mm high parapet CMU parapet wall at ground floor, non fire rated m2 80

3 300mm thick 1150mm high parapet CMU parapet wall at ground floor, non fire rated m2 18

Total for MASONRY

CARRIED TO SUMMARY

05 00 00 METALS

All metalworks herein shall be completed full incompliance with the Drawings V1-A902

and Specification.

05 12 00 Structural Steel Framing

1 Supply and fix 200mm x 50mm rectangular hollow aluminum powder coated pergola, m2 150

wall mounted, kind, quality, fittings, fixtures, accessories as per Drawings and as per

Page 533: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Specifications.

05 70 00 Decorative Metal

2 Supply and fix 50mm x 50mm galvanized steel powder coated hand rails for staircase, m 59

side mounted to stair slab, kind, quality, fittings, fixtures, accessories as shown on

Drawings and as per Specification.

Additional Items

3 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Total for METALS

CARRIED TO SUMMARY

06 00 00 WOOD, PLASTICS, AND COMPOSITES

06 41 00 Architectural Wood Casework

As per Question and Answer No. (89) the kitchen cabinet changed to Aluminum

1 Supply and fix kitchen under counter & overhead cabinets (2350mm + 800mm + nr 4

1320mm) long 600mm wide (counter tops measured separately) at kitchen with wall

cabinet MDF melamine laminated with aluminum edge, base & overhead cabinets with

polished chrome cabinet pull handles and all other accessories as per the Drawing nr V1-

A905 and Specification.

2 Supply and fix kitchen under counter & overhead cabinets 784mm long 600mm wide nr 4

(counter tops measured separately) at kitchen with wall cabinet MDF melamine

laminated with aluminum edge, base & overhead cabinets with polished chrome cabinet

pull handles and all other accessories as per the Drawing nr V1-A905 and Specification.

3 Supply and fix kitchen under counter & overhead cabinets 980mm long 600mm wide nr 4

(counter tops measured separately) at kitchen with wall cabinet MDF melamine

laminated with aluminum edge, base & overhead cabinets with polished chrome cabinet

pull handles and all other accessories as per the Drawing nr V1-A905 and Specification.

06 61 16 Solid Surfacing Fabrications

4 Supply and fix solid acrylic counter top shaped 550mm long 330mm wide with opening nr 4

for wash basin as shown in the Drawing nr V1-A903 and Specification.

Page 534: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

5 Supply and fix solid acrylic counter top shaped 550mm long 1020mm wide with opening nr 8

for wash basin as shown in the Drawing nr V1-A903 and Specification.

6 Supply and fix solid acrylic counter top shaped 1185mm long 600mm wide with opening nr 4

for wash basin as shown in the Drawing nr V1-A903 and Specification.

7 Supply and fix Solid Acrylic counter top (2350mm + 800mm + 1320mm) long 600mm nr 4

wide with opening for double bowl kitchen sink including waste disposal unit, 100mm up

stand for counter top as shown in the Drawing nr V1-A903 and Specification.

Wood, Plastics, and Composites (Cont'd)

1 Supply and fix solid acrylic counter top 784mm long 600mm wide including 100mm nr 4

upstand for counter top as shown in the Drawing nr V1-A903 and Specification.

2 Supply and fix solid acrylic counter top 980mm long 600mm wide including 100mm up nr 4

stand for counter top as shown in the Drawing nr V1-A903 and Specification.

Additional Items

3 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Total

Page 535: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for WOOD, PLASTICS, AND COMPOSITES

CARRIED TO SUMMARY

07 00 00 THERMAL AND MOISTURE PROTECTION

07 10 00 Damp proofing and Waterproofing

Substructure Waterproofing

All works herein shall be completed in full incompliance with the Drawings nr V-S002, VS003,

V-S004, V-S005, V-S401 and Specification.

1 Two coats of bitumen paint for sub structure for vertical surface. m2 401

2 Ditto for horizontal surface m2 281

3 Waterproofing works for substructure with vapour barrier 250 microns, horizontal m2 538

surface, as per the Drawings and Specification.

Wet Area Waterproofing / Roof Waterproofing

All works herein shall be completed in full incompliance with the Drawings nr V1-A202,V1-

A203, V1-A204, V1-A205,V1-A903, V1-A907 and Specification.

4 Waterproofing works for wet area, vertical surface, as per the Drawings and Specification m2 262

5 Waterproofing works for wet area, horizontal surface as per the Drawings and Specification m2 130

6 Waterproofing membrane for roof and second floor terrace, horizontal surface, width > m2 332

300mm, (kind, quality, method of fixing, thickness as per the Drawings and Specification)

7 Geotextile layer for roof and second floor terrace water proofing works, horizontal m2 332

surface, width > 300mm, (kind, quality, method of fixing, thickness as per the Drawings

and Specification)

Page 536: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

THERMAL AND MOISTURE PROTECTION (Cont'd)

1 100mm thick insulation for water proofing works at roof and second floor terrace water m2 332

proofing works, horizontal surface, width > 300mm, (kind, quality, method of fixing,

thickness as per the Drawings and Specification)

07 21 13 Board Insulation

2 Anti-vibration insulation, thickness as per the manufacturers requirements at water tank m2 27

bearing at room as per the Drawing nr V-S401 and Specification.

Total for THERMAL AND MOISTURE PROTECTION

CARRIED TO SUMMARY

08 00 00 OPENINGS

All works herein shall be completed in full compliance with the Doors & Windows Note

Schedule Drawings V1-A801, V1-A802, V1-A803 and Specification.

Note: Notwithstanding the Provisions of the Standard Method of Measurement, door

sets including doors, frames, vision panels, decoration and ironmongery have been

measured as a composite item and the Contractor should make due reference to the

drawings and specification. No claim for lack or want of knowledge will be entertained

08 11 00 Metal Doors and Frames

As per Question and Answer No (420)

1 Supply and fix steel flush door, 50mm thick, 1450mm wide x 2700mm high with 6mm low nr 4

glass +16+6mm clear glass vision panel including frame, type D1, finished with and

including paint, all accessories and hardware including but not limited to hinges HDH

type, outside door lock, lever handle and latch, wall stop with roses and escutcheons as

stated in the Specification

2 Supply and fix steel flush door, 54mm thick, 1000mm wide x 2700mm high with 6mm low nr 4

glass +16+6mm clear glass vision panel including frame, type D2, finished with and

including paint all accessories and hardware including but not limited to hinges HDH

Page 537: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

type, door stopper, outside door lock, lever handle and latch, wall stop with roses and

escutcheons as stated in the Specification

08 14 00 - Wood Doors

3 Supply and fix wooden flush decorative veneer door, 44mm thick, 900mm wide x nr 16

2200mm high including frame, type D3, finished with and including paint, all accessories

and hardware including but not limited to hinges BBS type, inside door lock, lever handle

and latch, wall stop with roses and escutcheons as stated in the Specification.

4 Supply and fix wooden flush door, 44mm thick, 900mm wide x 2200mm high including nr 24

frame, type D4, finished with and including paint, all accessories and hardware including

but not limited to hinges BBS type, inside door lock, lever handle and latch, wall stop with

roses and escutcheons as stated in the Specification.

08 51 00 Aluminum Windows

1 Supply and fix aluminum double glazed window, 3250mm wide x 2700mm high, nr 4

glass panel with open glass door window including frame, type W1, finished, all

accessories and hardware including but not limited to hinges, handle, lock, weather tight

strip etc. as stated in the Drawings and Specification.

2 Supply and fix aluminum double glazed window, 3250mm wide x 2700mm high, nr 4

aluminum sliding shutters 1074mm x 2700mm, in front sliding glass panel including

frame, type W1a, finished, all accessories and hardware including but not limited to

hinges, handle, lock, weather tight strip etc. as stated in the Drawings and Specification.

3 Supply and fix aluminum double glazed window, 2700mm wide x 2700mm high, nr 4

aluminum sliding shutters 1130mm x 2700mm, in front sliding glass panel including

frame, type W2, finished , all accessories and hardware including but not limited to

hinges, handle, lock, weather tight strip etc. as stated in the Drawings and Specification.

4 Supply and fix aluminum double glazed window, 1500mm wide x 2700mm high, nr 8

aluminum sliding shutters 1130mm x 2700mm, in front sliding glass panel including

frame, type W3, finished, all accessories and hardware including but not limited to

hinges, handle, lock, weather tight strip etc. as stated in the Drawings and Specification.

5 Supply and fix aluminum double glazed window, 1500mm wide x 2700mm high including nr 4

frame, type W4, finished, all accessories and hardware including but not limited to

hinges, handle, lock, weather tight strip etc. as stated in the Drawings and Specification.

Page 538: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

6 Supply and fix aluminum double glazed window, 1500mm wide x 2700mm high including nr 4

frame, type W5, finished, all accessories and hardware including but not limited to

hinges, handle, lock, weather tight strip etc. as stated in the Drawings and Specification.

7 Supply and fix aluminum double glazed window, 1500mm wide x 2700mm high, nr 12

aluminum swinging shutters 500mm x 2700mm, in front of glass panel, including frame,

type W5a, finished, all accessories and hardware including but not limited to hinges,

handle, lock, weather tight strip etc. as stated in the Drawings and Specification.

OPENINGS (Cont'd)

08 83 00 Mirrors

1 Supply and fix fixed mirror 650mm width x 1050mm high for bathrooms ( size, kind, nr 4

quality, surface treatment, method of jointing, etc. as per the Drawings nr V1-903 and

Specification).

2 Supply and fix fixed mirror 1000mm width x 1050mm high for bathrooms ( size, kind, nr 8

quality, surface treatment, method of jointing, etc. as per the Drawings nr V1-903 and

Specification).

3 Supply and fix fixed mirror 1025m width x 1100mm high for bathrooms ( size, kind, nr 4

quality, surface treatment, method of jointing, etc. as per the Drawings nr V1-903 and

Specification).

08 00 00 Openings

Additional Items

4 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

4.1 Supply and fix fixed mirror 1080 x 1050mm high nr 4

4.2 lm 49

4.3 M²

GLASS SCREENSAs per Question and Answer No. (99)

4.4 8mm tempered glass door and partition size 840 x 2400 mm nr 4

As per Question and Answer No. (544) toughened laminated glass balustrade behind shutter where applicable

As per Question and Answer No. (531) Electrically Operated Sliding Shutter System (OPTIONAL)

Page 539: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

4.5 8mm tempered glass door and partition size 900 x 2000 mm nr 4

4.6 8mm tempered glass door and partition size 955 x 2000 mm nr 4

Total for OPENINGS

CARRIED TO SUMMARY

09 00 00 - FINISHES

09 23 00 Gypsum Board wall

1 Gypsum wall above wooden cabinet closet m2 17

09 24 00 Cement Plastering

2 15mm thick internal Plastering for block walls to receive paint m2 347

3 Ditto for walls to receive tiling at wet areas, m2 244

09 30 13 Ceramic Tiling

Floor Tiling

1 Porcelain tile flooring (type - FT1), size 600mm x 600mm, m2 745

2 Glazed porcelain stoneware tile flooring (type - FT5), size 600mm x 600mm m2 146

3 Procelain tiles (FT5), size 600mm x 600mm for balcony m2 148

4 Terrazzo tiles size 400x400mm (roof), m2 183

As per client Question and AnswerNo. 63, the balcony floor finish is changed to porcelain tiles FT5

Page 540: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Wall tiling

5 Mosaic tile (type WT4) 100mm x 300mm size for kitchen walls, m2 110

6 White body wall tile (type WT1) 325mm x 977mm size for toilets and bathroom walls, m2 340

FINISHES (Cont'd)

Skirting

As per client Question and Answer No 293, the height for skirting 100mm1

m 504

2 Porcelain tile skirting 100mm height (type - FT1) for kitchen and laundry area, fixed over m 47

cement sand plastering, thickness, method of construction, layout and treatments,

method of jointing, etc. as per the Drawing nr and Specification.

3 Terrazzo tile skirting 100mm height, vertical, fixed over cement sand plaster for second m 98

floor balcony (thickness, kind, quality, size, method of construction, layout and

treatments, moisture resistant treatment, method of jointing, etc. as per the Drawings

and Specification).

As per Client Q&A No. 63 the skirting for stair case to be porcelain

4 Poreclain Skirting 100 mm height m 78

Stair Finish

4 Porcelain tile tread (type - FT1), 280mm wide x 1100mm length, m 194

5 Porcelain tile for riser (type - FT1), 160mm high x 1100mm length, m 176

6 Glazed porcelain stoneware tile for tread (type - FT5), 280mm wide x 3715mm straight m 30

steps for exterior stairs,

As per client Question and Answer No. 89 wall finish at back of Kitchen Cabinets is Render

MDF skirting 100mm height, vertical, fixed over cement sand plaster (thickness, kind,quality, size, method of construction, layout and treatments, moisture resistant treatment, method of jointing, etc. as per the Drawings and Specification).

As per client Question and Answer No 76, the balcony skirting is changed to porcelain skirting 100mm high

Page 541: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

7 Glazed porcelain stoneware tile for riser (type - FT5), 150mm wide x 3715mm straight m 45

steps for exterior stairs,

8 Glazed porcelain stoneware tile for tread (type - FT5), 280mm wide x 2000mm straight m 16

steps for exterior stairs, including bullnose,

9 Glazed porcelain stoneware tile for riser (type - FT5), 150mm wide x 2000mm straight m 24

steps for exterior stairs,

FINISHES (Cont'd)

09 50 00 Ceilings

1 Supply and install gypsum ceiling, depth of suspension 500 - 1000 mm (thickness of lining m2 240

and method of fixing system to structure, kind, quality, size, nature of backgrounds,

insulation materials etc. as per the Drawings nr V1-A906,V1-A901 and Specification)

2 m2 35

3 Supply and install gypsum ceiling for toilets, laundry and baathrooms m2 95

09 75 13 Stone Wall Facing

3 Stone cladding for parapet walls at ground floor, m2 187

09 91 00 - Painting

Wall -Painting

4 Painting for internal walls, m2 1461

5 Painting for walls in staircases, m2 452

Ceiling -Painting

6 Painting for ceiling, m2 334

7 Painting for staircase ceiling, m2 121

Supply and install gypsum ceiling for kitchen area depth of suspension 500-1000mm as per drawing nr.V1-A905, V1-A901 and specs

Page 542: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

8 Painting for gypsum board ceiling m2 370

Total for FINISHES

CARRIED TO SUMMARY

10 00 00 SPECIALTIES

10 28 00 –Toilet, Bath and Laundry Accessories

Supply & install Plumbing Fixtures as shown in Drawing nr V1-A903 and Technical

Specification including all accessories, fittings , flexible connections etc.

1 Paper towel dispenser (PTD) nr 16

10 44 13.13 Portable Fire Extinguishers

All items hereunder to be described with kind, quality, size, method of fixing , etc. as per

the Drawings and Specification).

2 Supply & install Portable Fire Extinguishers nr 4

3 Supply & install fire blanket nr 4

10 57 00 Wardrobe and Closet Specialties

4 Supply and fix wardrobe 1985 mm length, 600mm wide, 2400mm high, with MDF nr 4

laminated dark wood veneer shelves, door with MDF white matt lacquer finish and

chromed stainless steel handles, and all other accessories as per the Drawing nr V1-A905

and Specification.

5 Supply and fix wardrobe 1260 mm length, 600mm wide, 800mm high, with MDF nr 4

laminated dark wood veneer shelves, door with MDF white matt lacquer finish and

chromed stainless steel handles, and all other accessories as per the Drawing nr V1-A905

and Specification.

6 Supply and fix wardrobe 1895 mm length, 600mm wide, 2400mm high, with MDF nr 4

laminated dark wood veneer shelves, door with MDF white matt lacquer finish and

chromed stainless steel handles, and all other accessories as per the Drawing nr V1-A905

and Specification.

Page 543: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

7 Supply and fix wardrobe 1875 mm length, 600mm wide, 2400mm high, with MDF nr 4

laminated dark wood veneer shelves, door with MDF white matt lacquer finish and

chromed stainless steel handles, and all other accessories as per the Drawing nr V1-A905

and Specification.

8 Supply and fix timber shelves nr 4

SPECIALTIES (Cont'd)

10 00 00 Specialties

Additional Items

1 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

1.01 Towel ring nr 12

1.02 Robe Hook nr 12

1.03 Towel Bar nr 12

1.04 Soap Dish nr 12

1.05 Towel Pin nr 12

Total for SPECIALTIES

CARRIED TO SUMMARY

11 00 00 EQUIPMENT

Page 544: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

All items hereunder to be described with information such as appropriate to the

procurement , design, supply, execution, type, kind, quality, size, method of fixing ,

specified codes of practice, etc. as per the Drawings and Specification).

11 30 00 Residential Equipment

AS PER Q&A-77 NOT INCLUDED

1 Refrigerator/freezer nr 1

2 Exhaust hoods nr 4

AS PER Q&A-77 NOT INCLUDED

3 Cooker nr 4

AS PER Q&A-77 NOT INCLUDED

4 Washing Machine nr 4

11 00 00 Equipment

Additional Items

5 The Contractor is to list here and price any items shown on the Drawings, mentioned in Item

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Page 545: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for EQUIPMENT

CARRIED TO SUMMARY

12 00 00 FURNISHING

All items hereunder to be described with information such as appropriate to the

procurement , design, supply, execution, type, kind, quality, size, method of fixing ,

specified codes of practice, etc. as per the Drawings and Specification).

12 00 00 Furnishing

Additional Items

1 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Page 546: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for FURNISHING

CARRIED TO SUMMARY

22 00 00 - PLUMBING

All items hereunder to be described specified code of practice and regulations, kind,

quality, size, method of fixing , finishes or surface treatments, etc. as per the Drawings

and Specification).

22 05 23 General-Duty Valves for Plumbing Piping

Page 547: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Valves

Valves are classified according to type . Material and/or size . Rates include furnishing

and installing of valves, testing at manufacturer's premises and on site; diameters of

valves and water meter according to pipe diameter which will be connected with it; as

per Drawings and Specification.

Gate Valve

1 20 mm diam. nr 12

2 25 mm diam. nr 32

3 40 mm diam. nr 4

4 50 mm diam. nr 32

Angle Valve

5 20 mm diam. nr 80

6 25 mm diam. nr 16

Globe Valve

7 20 mm diam. nr 8

8 25 mm diam. nr 20

9 50 mm diam. nr 4

Non-Return Valve

10 20 mm diam. nr 8

11 25 mm diam. nr 16

12 50 mm diam. nr 8

Pressure Reducing Valve

13 50 mm diam. nr 4

Page 548: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

22 11 16 Domestic Water Piping

Domestic water piping is classified by material and diameter. Rates include furnishing

and installing of pipes, fittings, accessories, fixing supports, joints, sleeves, special parts,

connections, hanger supports. Rates to include all works and materials necessary for

complete installation for piping system as per the Drawings and Specification.

Water Supply System

1-Cold Water Supply

1 50 mm diameter. m 140

2 40 mm diameter. m 40

3 25 mm diameter. m 280

4 20 mm diameter. m 260

2-Hot Water Supply

5 20 mm diameter. m 220

3 - Accessories

6 Hose Bibb 20mm . nr 8

7 Water Meter 50 mm. nr 4

8 Water Hammer Arrestor nr 28

9 Automatic Air Vent. nr 8

10 Pressure Gauge . nr 8

11 Strainer 50 mm. nr 4

Page 549: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

22 13 16 Sanitary Waste and Vent Piping

Sanitary Pipe Works

Sanitary pipe works is classified by material and diameter. Rates include furnishing and

installing of pipes, fittings, accessories, fixing support, joints, sleeves , special parts,

connections, hanger supports. Rates for pipework below ground also include excavation,

backfilling , civil work, trenches and any other accessories or fittings necessary for

complete installation of the piping system. Testing of pipes at the manufacturer's

premises is included. All as per the Drawings and Specification.

Pipes and fitting above ground

Waste Pipe

12 50 mm diameter. m 48

13 75 mm diameter. m 80

14 110 mm diameter. m 108

Soil Pipe

15 110 mm diameter. m 120

PLUMBING (Cont'd)

Pipes and fitting below ground

Waste pipe

1 75 mm diameter. m 32

2 110 mm diameter. m 40

Soil Pipe

3 110 mm diameter. m 72

Vent Pipe Works

Page 550: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Vent pipes are classified by material and diameter. Rates include furnishing and installing

of pipes, fittings, accessories, fixing support, joints, sleeves, special parts, connections,

hanger supports. Rates include furnishing and installing of pipes, fittings, accessories,

fixing support, joints, sleeves , special parts, connections, hanger supports. Rates for

pipework below ground also include excavation, backfilling , civil work, trenches and any

other accessories or fittings necessary for complete installation of the piping system.

Testing of pipes at the manufacturer's premises is included. All as per the Drawings and

Specification.

Pipes and fittings above ground

4 75 mm diameter. m 88

Pipes and fitting below ground

5 75 mm diameter. m 20

22 13 19.13 Sanitary Drains

Sanitary drains (to include rainwater pipework and condensate drain pipework) are

classified by material and diameter. Rates include furnishing and installing of pipes,

fittings, accessories, fixing supports, joints, sleeves, special parts, connections, hanger

supports. Rates also include testing of pipes at the manufacturer's premises. All as per

the Drawings and specification.

Rain water Pipe

6 75 mm diameter. m 100

Condensate Drain Pipe Works

7 20 mm diameter. m 48

8 25 mm diameter. m 28

Page 551: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

PLUMBING (Cont'd)

22 33 00 Electric Domestic Water Heaters

Electric domestic water heaters are classified according to capacity. Rates include

furnishing of heater complete with safety valves, air vent, pressure and temperature

relief gauges, drain valves, all valves set (angle, gate, non return, etc. .), thermostat,

heating element, contactors, switch, support, bolts, nuts, connection of pipes, testing on

site, commissioning and putting into service.

1 EWH-V1-01 with (30 liters / 1200 W) capacity. nr 8

2 EWH-V1-02 with (100 liters / 1500 W) capacity. nr 8

3 EWH-V1-03 with (80 liters / 1200 W) capacity. nr 8

22 40 00 Plumbing Fixtures

All items described hereunder to be of kind, quality, size, nature of base, method of

fixing, complete with accessories etc. as per the Drawings nr V1-903 and Specification

4 Floor Drain (FD) nr 24

5 Flexible Shower Hose nr 16

6 Water Closet nr 16

7 Floor clean out nr 16

8 Roof drain nr 12

9 Vent cap nr 4

10 Bath tub (BT) including taps, plug, accessories and fitting. nr 4

As per the drawing it is integrated

11 Wash basin (WB) nr 16

As per Q&A no. 358 clothes washing not in contract only connection

12 Washing machine connections (washing machine not in contract) nr 4

As per Q&A no. 360 shower channel to be used

13 Shower (SHO) including shower channel, mixer tap, fitting, spray and adjustable bar nr 8

Page 552: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

PLUMBING (Cont'd)

As per Q&A-383, the sink bowl is

1 Kitchen sink nr 4

2 Taps for wash basin including fittings , plugs, valves, connections and waste. nr 16

3 Mixer tap for kitchen sink including fitting, plugs, chrome plated pipes, valves and nr 4

waste

22 00 00 - Plumbing

Additional Items

4 Inspection chamber as per Drawings and Specification; connected directly to nr 4

sewer network.

5 Clean out (CO) nr 12

6 Roof Water tank as per Specification; rate shall be include supplying and installing, nr 4

all fittings, accessories, valves, pipework, vents etc. as per the Drawings and

Specification

7 Balcony Drain nr 4

8 Gully Trap nr 4

Additional Items

9 Marking the position of holes, mortices and chases in the structure Item 1

10 Identification; plates, discs, labels, tapes, bands, arrows, symbols, letters, numbers and Item 1

charts; as stated on drawings and in Specification

11 Testing and commissioning of entire installation Item 1

12 Preparation of as-built drawings Item 1

13 Preparation of operation and maintenance manuals Item 1

14 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Page 553: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for PLUMBING

CARRIED TO SUMMARY

23 00 00 - HEATING, VENTILATING, AND AIR CONDITIONING (HVAC)

All HVAC works shall be completed as per the Drawings and Specification.

23 23 00 Refrigerant Piping

Supply and fix refrigerant pipes for FCU from condensing units to indoor installed AC

units including fittings, sleeves and all accessories as per the Drawings and Specification

1 20 mm diameter with max liquid line 10 mm. m 380

23 31 00 HVAC Ducts and Casings

All items described hereunder to be of type, kind, quality, size, method of fixing, specified

codes of practice, method of fixing/supports, etc. as per the Drawings and Specification

Notwithstanding the provisions of the Standard Method of Measurement, internal Note

ductwork is to include insulation to the ductwork. No claim for additional cost due to lack

or want of knowledge will be entertained

2 Supply and fix insulated indoor galvanized steel sheet metal duct work for all HVAC work Kg 1240

Page 554: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

as specified and as indicating on drawings, complete with bends, supports, connections,

fittings, splices and all accessories to complete the work.

HEATING, VENTILATING, AND AIR CONDITIONING (Cont'd)

23 33 13.13 Volume-Control Dampers

All items described hereunder to be of type, kind, quality, size, method of fixing, specified

codes of practice, etc. as per the Drawings and Specification

Volume Dampers

1 Volume Damper ; 200 mm dia. circular damper nr 4

2 Volume Damper ; 300 mm dia. circular damper nr 4

3 Volume Damper ; 900x150 mm nr 8

23 33 46 Flexible Ducts

All items described hereunder to be of type, kind, quality, size, method of fixing, specified

codes of practice, etc. as per the Drawings and Specification

4 Supply and install flexible duct with insulation; size 200 mm dia. m 4

5 Supply and install flexible duct with insulation; size 300 mm dia. m 6

23 34 00 HVAC Fans

All items described hereunder to be of capacity, design, supply, execution, type, kind,

quality, size, method of fixing , specified codes of practice, etc. as per the Drawings and

Specification

Supply and install exhaust fan as specified and as indicated in drawing. Fan consists of

casing, fan, motor, control, filter, sand trap louver, all electrical works (components,

wiring, switches etc.) and all accessories. Electrical power supply 220/1/60.

Wall Mounted

Page 555: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

6 Exhaust Fan (EF-01) 40 Pa with total air flow 50 L/S . nr 4

Ceiling Mounted

7 xhaust Fan (EF-02 to EF-07)) 100 Pa with total air flow 25 L/S nr 24

Range Hood Fan

8 Range Hood Fan (RH-01) ;150 Pa with total air flow 50 L/S . nr 4

HEATING, VENTILATING, AND AIR CONDITIONING (Cont'd)

23 37 00 Air outlets and Inlets

All items described hereunder to be of type, kind, quality, size, method of fixing, specified

codes of practice, etc. as per the Drawings and Specification

Supply and install painted supply linear bar air register with complete accessories as per

the Drawings and Specification

1 Size 600x150 mm ; 200 L/s . nr 4

2 Size 800x150 mm ; 235 L/s. nr 4

3 Size 800x150 mm ; 255 L/s. nr 4

Page 556: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

4 Size 800x150 mm ; 260 L/s. nr 4

5 Size 900x150 mm ; 330 L/s. nr 4

6 Size 1000x200 mm ; 510 L/s . nr 4

Supply and install painted return linear bar air grille with complete accessories as per the

Drawings and Specification.

7 Size 600x150 mm ; 200 L/s . nr 4

8 Size 800x150 mm ; 235 L/s. nr 4

9 Size 800x150 mm ; 255 L/s. nr 4

10 Size 800x150 mm ; 260 L/s. nr 4

11 Size 900x150 mm ; 330 L/s. nr 4

12 Size 1000x200 mm ; 510 L/s . nr 4

Supply and install 3 way Supply ceiling diffuser with complete accessories.as per the

Drawings and Specification.

13 Size 375X375 mm ; 100 L/s. nr 4

14 Size 450X450 mm ; 200 L/s. nr 4

Supply and install 4 way return ceiling diffuser with complete accessories as per the

Drawings and Specification.

15 Size 450X450 mm ; 200 L/s. nr 4

Exhaust air louver

16 Exhaust air louver (250X100)mm. nr 12

17 Exhaust air louver (250X150)mm. nr 16

Page 557: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

HEATING, VENTILATING, AND AIR CONDITIONING (Cont'd)

23 82 00 Convection Heating and Cooling Units

All items described hereunder to be of capacity, design, supply, execution, type, kind,

quality, size, method of fixing , specified codes of practice, etc. as per the Drawings and

Specification

Supply and install concealed fan coil unit as specified and as indicated in drawing. Unit to

be complete with air cooled condensing unit, fan, filter, valves, controls, thermostat, all

electrical works (components, wiring, switches etc.) and all accessories. Electrical power

supply 220/1/60.

1 (FCU-01) , 347 L / s , 50 Pa ; Electrical data power 4.5 KW . nr 4

2 (FCU-02) , 530 L / s , 50 Pa ; Electrical data power 4.5 KW . nr 4

3 (FCU-03) , 259 L / s , 50 Pa ; Electrical data power 3 KW . nr 4

4 (FCU-04) , 235 L / s , 50 Pa ; Electrical data power 3 KW nr 4

5 (FCU-05) , 197 L / s , 50 Pa ; Electrical data power 3 KW . nr 4

6 (FCU-06) , 509 L / s , 50 Pa ; Electrical data power 4.5 KW nr 4

23 05 93 Testing, Adjusting and Balancing for HVAC

All items described hereunder to be as required by type of installation, preparatory

operations, stages of test (nr), required attendance, applicable codes etc. as per the

Drawings and Specification).

7 Air balancing of the ducting network Item 1

8 Testing, balancing and commissioning of all the equipment Item 1

Page 558: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

HEATING, VENTILATING, AND AIR CONDITIONING (Cont'd)

23 00 00 - Heating, Ventilating, and Air Conditioning (HVAC)

Additional Items

1 Marking the position of holes, mortices and chases in the structure Item 1

2 Identification; plates, discs, labels, tapes, bands, arrows, symbols, letters, numbers and Item 1

charts; as stated on drawings and in Specification

3 Testing and commissioning of entire installation Item 1

4 Preparation of as-built drawings Item 1

5 Preparation of operation and maintenance manuals Item 1

6 The Contractor is to list here and price any items shown on the Drawings, mentioned in Item

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Page 559: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for HVAC

CARRIED TO SUMMARY

26 00 00 - ELECTRICAL

Note: the measurement below is for a block of four Villa type A1

All works hereunder shall be completed as per the Drawings and Specification.

26 05 19 Low Voltage Electrical Power Conductors and cables

All items hereunder to be of type, kind, number of cores, armoring and sheathings,

method of fixing , specified codes of practice, etc. as per the Drawings and Specification).

Notwithstanding the Provisions of the method of measurement, cables have been

itemised and referenced to the circuit. The contractor is to make due reference to

drawings nrs E000, E001, E002, E003, EL201, EL202, EP201, EP202, LP201, LP202, LP203,

PS301, PS302 MD401, MD402 and MD403 for full details and is to allow for all cabling,

junctions, flexible connections, feeder units etc. required to complete the installation in Note

accordance with the drawings and Specification. No claim for want or lack of knowledge

will be entertained

1 Lighting circuits Item 1

2 Power circuits Item 1

3 Fire alarm circuits Item 1

4 Cooker circuits Item 1

5 Water heater circuits Item 1

6 Fan circuits Item 1

7 Outdoor lighting circuits Item 1

8 HVAC control circuits Item 1

Page 560: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

ELECTRICAL (Cont'd)

26 05 26 Grounding and Bonding for Electrical Systems

All items hereunder to be described with information such as type, kind, number of

cores, armoring and sheathings, method of fixing , specified codes of practice, etc. as per

the Drawings and Specification).

1 Grounding system Item 1

26 05 33.13 Conduit for Electrical Systems

All items hereunder to be described with information such as type, kind, , method of

fixing , specified codes of practice, etc. as per the Drawings and Specification).

Notwithstanding the Provisions of the method of measurement, conduits have been

itemised and referenced to the circuit. The contractor is to make due reference to

drawings nrs E000, E001, E002, E003, EL201, EL202, EP201, EP202, LP201, LP202, LP203,

PS301, PS302 MD401, MD402 and MD403 for full details and is to allow for all tracking,

fixings, type, size, materials, boxes, connections etc. required to complete the installation

in accordance with the drawings and Specification. No claim for want or lack of

knowledge will be entertained

2 Lighting circuits Item 1

3 Power circuits Item 1

4 Fire alarm circuits Item 1

5 Cooker circuits Item 1

6 Water heater circuits Item 1

7 Fan circuits Item 1

8 Outdoor lighting circuits Item 1

9 HVAC control circuits Item 1

Page 561: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

ELECTRICAL (Cont'd)

26 24 13 Switchboards

1 All items hereunder to be described with information such as type, kind, rated capacity,

method of fixing, cores reference to Specification, fuses, background, specified codes of

practice, etc. as per the Drawings and Specification).

26 24 16 Panel boards

All items hereunder to be described with information such as type, kind, rated capacity,

method of fixing, cores reference to Specification, fuses, background, specified codes of

practice, etc. as per the Drawings and Specification).

2 Distribution and panel boards Item 1

26 27 13 Electricity Metering

3 All items hereunder to be described with information such as type, kind, rated capacity, Item 1

method of fixing, cores reference to Specification, fuses, background, specified codes of

practice, etc. as per the Drawings and Specification).

26 27 26 Wiring Devices

Notwithstanding the Provisions of the Method of Measurement, wiring devices shall Note

include final circuits. No claim for lack or want of knowledge shall be entertained

Switches & Push Buttons

All items hereunder to be described with information such as appropriate to the

procurement , type, kind, quality, size, method of fixing , specified codes of practice, etc.

as per the Drawings and Specification).

4 One way one gang switch nr 24

Page 562: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

ELECTRICAL (Cont'd)

1 One way two gang switch nr 36

2 One way three gang switch nr 12

3 Two way one gang switch nr 12

Power Outlets

4 Single outlet nr 60

5 Double outlet nr 60

6 1 way 20A 2P 230v switch with pilot light nr 24

7 Fusible disconnect switch, double poles, 20A, 230V, with lamp Indicator nr 24

8 Non-fusable disconnect switch, 1 phase nr 24

26 50 00 Lighting

Notwithstanding the Provisions of the Method of Measurement, lighting shall include

final circuits. No claim for lack or want of knowledge shall be entertained

All items hereunder to be described with information such as appropriate to the

procurement , type, kind, quality, size, method of fixing , specified codes of practice, etc.

as per the Drawings and Specification).

9 Luminaries, down light, multi-mounting, 1 x 26W CFL; type D1 nr 32

Page 563: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

ELECTRICAL (Cont'd)

1 Luminaries, down light, multi-mounting, 2 x 26W CFL; type D2 nr 56

2 Luminaries, down light, recessed-mounting, 2 x 26W CFL; compact lamp 220V, 60hz; type nr 16

D3

3 Luminaire, ceiling mounted, square shape; 4 x 18W, 220V, 60hz; type B2 nr 20

4 Luminaire, down light square shaped, 1 nr x 18W, 220V, 60hz; type S2 nr 24

5 Luminaire, ceiling mounted, round shaped; 1 x 18W, 220V, 60hz; type R2 nr 32

6 Luminaire, wall mounted, satin steel/nickel/plastic, white; 1 x 13W, 12V; type A1 nr 4

7 Luminaire, wall mounted, satin steel/nickel/plastic, white; 1 x 18W, CPL; type W2 nr 16

8 Luminaire, wall mounted, satin steel/nickel/plastic, white; 1 x 2W, CPL; type W3 nr 56

9 Luminaire, wall mounted, rectangular shape; 1 x 4W CPL, outdoor; type W6 nr 36

10 Luminaire, wall mounted; 1 x 26W CPL, outdoor; type W7 nr 8

11 Luminaire, bollard type including bollard; HPF, HF electronic ballast with opal plain glass nr 8

diffuser; 220V, outdoor; type LS2

ELECTRICAL (Cont'd)

26 00 00 - Electrical

Additional Items

1 Marking the position of holes, mortices and chases in the structure Item 1

Page 564: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2 Identification; plates, discs, labels, tapes, bands, arrows, symbols, letters, numbers and Item 1

charts; as stated on drawings and in Specification

3 Testing and commissioning of entire installation Item 1

4 Preparation of as-built drawings Item 1

5 Preparation of operation and maintenance manuals Item 1

6 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

6.01 m 484C 50mm² CU/XLPE/PVC+25mm² CU/PVC E (Cable from kWH meter to DB) (As per Q&A # 537)

Page 565: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for ELECTRICAL

CARRIED TO SUMMARY

27 00 00 COMMUNICATIONS

Note: the measurement below is for a block of four Villa type V1 Note

STRUCTURED CABLING SYSTEM

Supply, Install, Test, connect and commission inclusive of all cabling, conduits and

containment, socket outlets, all in accordance with the relevant service provider regulations ,

rules, recommendation and requirements and in accordance with the specifications and

drawings.

1 Information Outlet, Flush Type 1 DATA, 1 Telephone 0.3 Meters A.F.F.L. nr 24

2 Telephone Outlet, Wall Mounted Flush Type, MTD 0.30m A.F.F.L nr 12

3 Telephone Outlet, Wall Mounted, Flush Type 1.2 Meters A.F.F.L. nr 4

4 TV outlet, wall mounted nr 20

5 9U Telecom Cabinet, Wall Mounted nr 4

6 Set Top Box nr 20

7 LED TV nr 20

8 CAT 6A, UTP Cable m 680

9 Single Mode Fiber Optic Cable - 1 x 4 Core m See Master plan BOQ

Page 566: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Video Entry System / Intercom

Supply, Install, Test, connect and commission inclusive of all cabling, conduits and

containment, socket outlets, all in accordance with the relevant service provider regulations ,

rules, recommendation and requirements and in accordance with the specifications and

drawings.

1 Entrance Video Door Station nr 4

2 Residential Main Station nr 4

3 Door release 12V nr 4

4 Wireless Handset nr 8

5 CAT 6A, UTP Cable m 40

Consumption Metering

Supply, Install, Test, connect and commission inclusive of all cabling, conduits and

containment, socket outlets, all in accordance with the relevant service provider regulations ,

rules, recommendation and requirements and in accordance with the specifications and

drawings.

6 Metering Receiver nr 4

7 M-bus Cable, 2 x 18AWG m 64

Fire Alarm System

Supply, install, connection, testing and commissioning of wiring and equipment for Fire

Alarm System including all necessary materials and accessories to reflect complete system

installation.

8 Addressable, smoke detector nr 24

9 Addressable, heat detector nr 4

10 Multisensor Detector nr 4

11 Addressable, Manual Pull Station nr 4

Page 567: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

12 Sounder / Fire Alarm Bell / Horn nr 12

Fire Alarm System (cont'd)

1 Control Module nr 4

2 Fire Alarm Control Panel nr 4

3 Power Supply Unit, 24v nr 4

4 Loop Cable, 2x1.5mm2 Fire Resistant nr 280

5 24V Cable, 2x2.5mm2 Fire Resistant m 108

Additional Items

6 Marking the position of holes, mortises and chases in the structure Item 1

7 Identification; plates, discs, labels, tapes, bands, arrows, symbols, letters, numbers and Item 1

charts; as stated on drawings and in Specification

8 Testing and commissioning of entire installation Item 1

Page 568: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

9 Preparation of as-built drawings Item 1

10 Preparation of operation and maintenance manuals Item 1

11 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

ADDITIONAL (As per Q&A 487)

1 ACTIVE COMPONENTS (AS PER Q&A 487) DISTRIBUTION CABINET nr 4

Total for COMMUNICATIONS

CARRIED TO SUMMARY

Page 569: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

31 00 00 EARTHWORK

All works herein shall be completed in full compliance with the Drawings nr V-S001,VS002,

V-S003,V-S004,V-S005,V-S401and Specification.

31 10 00 Site Clearing

1 Site preparation, clearing site vegetation m2 587

31 23 16 Excavation

2 Excavating top soil for preservation, average depth 150mm. m2 587

3 Excavating pits(33 nr), maximum depth ≤ 2.00m. m3 468

4 Excavating trenches for grade beams, width ≤ 0.3m m3 22

31 23 23 .13 Backfill

5 Filling to excavations, average thickness > 0.25 m, arising from excavated materials, all fill m3 356

shall be compacted to 75% relative density for cohesion-less soils as per ASTM

D4254/ASTM D4293 or 95% maximum density as determined by ASTM D698 for cohesive

material, as per the Drawings and Specifications).

31 23 23.23 Compaction

6 Surface treatments, compacting bottom of excavation, compaction to meet 85% of m2 721

relative density for cohesion-less soils or 95% maximum density as determined by ASTM

D1557 for cohesive materials per the Drawings and Specifications)

31 23 16.26 Rock Removal

7 Disposal of excavated material, off site as stated in the Specification. m3 222

31 31 16 Termite Control

Page 570: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1 Termite control for the horizontal surface (method and type of treatment as per the m2 721

Drawings and Specifications)

2 Termite control for vertical surface (method and type of treatment as per the Drawings m2 774

and Specifications)

Additional Items

3 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Total for EARTHWORK

CARRIED TO SUMMARY

03 00 00 Concrete

04 00 00 Masonry

05 00 00 Metal

06 00 00 Wood, Plastics and Composites

07 00 00 Thermal and Moisture Protection

08 00 00 Openings

09 00 00 Finishes

10 00 00 Specialties

11 00 00 Equipment

12 00 00 Furnishing

22 00 00 Plumbing

Page 571: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

23 00 00 Heating, Ventilating and Air Conditioning (HVAC)

26 00 00 Electrical

27 00 00 Communications

31 00 00 Earthwork

SUBTOTAL

38

AMOUNT FOR VILLA TYPE V2 TO SUMMARY

MULTIPLY BY 38 NR BLOCKS

Page 572: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Rate Amount

164.00 7,052.00

380.00 40,280.00

296.00 12,728.00

573251.00 573,251.00

25.00 27,425.00

17.00 5,576.00

376.00 1,128.00

17.00 13,073.00

32.00 1,760.00

11.00 550.00

21.00 168.00

Page 573: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 682,991.00

US Dollar. 682,991.00

34.00 11,866.00

35.00 2,800.00

78.00 1,404.00

US Dollar. 16,070.00

163.00 24,450.00

Page 574: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

226.00 13,334.00

US Dollar. 37,784.00

4982.00 19,928.00

904.00 3,616.00

1118.00 4,472.00

199.00 796.00

Page 575: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

387.00 3,096.00

417.00 1,668.00

1159.00 4,636.00

CF 38,212.00

BF 38,212.00

152.00 608.00

190.00 760.00

Page 576: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1,368.00

US Dollar. 39,580.00

5.00 2,005.00

5.00 1,405.00

2.00 1,076.00

22.00 5,764.00

22.00 2,860.00

37.00 12,284.00

3.00 996.00

Page 577: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 26,390.00

BF 26,390.00

23.00 7,636.00

34.00 918.00

US Dollar. 34,944.00

2641.00 10,564.00

1564.00 6,256.00

Page 578: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

953.00 15,248.00

952.00 22,848.00

CF 54,916.00

BF 54,916.00

5977.00 23,908.00

6856.00 27,424.00

5312.00 21,248.00

3658.00 29,264.00

1547.00 6,188.00

Page 579: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

640.00 2,560.00

1371.00 16,452.00

CF 127,044.00

BF 127,044.00

82.00 328.00

82.00 656.00

97.00 388.00

85.00 340.00

305.00 14,945.00

723.00 0.00

580.00 2,320.00

Page 580: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

796.00 3,184.00

864.00 3,456.00

25,617.00

US Dollar. 207,577.00

44.00 748.00

22.00 7,634.00

21.00 5,124.00

CF 13,506.00

BF 13,506.00

55.00 40,975.00

51.00 7,446.00

51.00 7,548.00

32.00 5,856.00

Page 581: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

53.00 5,830.00

72.00 24,480.00

CF 92,135.00

BF 92,135.00

17.00 8,568.00

19.00 893.00

19.00 1,862.00

19.00 1,482.00

17.00 3,298.00

19.00 3,344.00

24.00 720.00

Page 582: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

18.00 810.00

24.00 384.00

18.00 432.00

CF 21,793.00

BF 21,793.00

54.00 12,960.00

56.00 1,960.00

56.00 5,320.00

142.00 26,554.00

11.00 16,071.00

11.00 4,972.00

11.00 3,674.00

11.00 1,331.00

Page 583: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

11.00 4,070.00

CF 76,912.00

US Dollar. 204,346.00

21.00 336.00

54.00 216.00

76.00 304.00

1389.00 5,556.00

294.00 1,176.00

1326.00 5,304.00

Page 584: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1311.00 5,244.00

1239.00 4,956.00

CF 23,092.00

BF 23,092.00

35.00 420.00

17.00 204.00

31.00 372.00

22.00 264.00

17.00 204.00

1,464.00

US Dollar. 24,556.00

Page 585: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

AS PER Q&A-77 NOT INCLUDED

IN THE SCOPE OF WORKS

465.00 1,860.00

AS PER Q&A-77 NOT INCLUDED

IN THE SCOPE OF WORKS

AS PER Q&A-77 NOT INCLUDED

IN THE SCOPE OF WORKS

Page 586: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

US Dollar. 1,860.00

Page 587: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

US Dollar. 0.00

Page 588: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

20.00 240.00

25.00 800.00

48.00 192.00

65.00 2,080.00

inclucded in sanitary fixtures section 224000

inclucded in sanitary fixtures section 224000

68.00 544.00

72.00 1,440.00

232.00 928.00

20.00 160.00

23.00 368.00

61.00 488.00

366.00 1,464.00

Page 589: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 8,704.00

BF 8,704.00

40.00 5,600.00

30.00 1,200.00

17.00 4,760.00

14.00 3,640.00

16.00 3,520.00

29.00 232.00

1618.00 6,472.00

46.00 1,288.00

96.00 768.00

46.00 368.00

96.00 384.00

Page 590: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

11.00 528.00

17.00 1,360.00

29.00 3,132.00

29.00 3,480.00

CF 36,732.00

BF 36,732.00

27.00 864.00

36.00 1,440.00

36.00 2,592.00

Page 591: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

17.00 1,496.00

27.00 540.00

17.00 1,700.00

9.00 432.00

10.00 280.00

Page 592: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 9,344.00

BF 9,344.00

275.00 2,200.00

322.00 2,576.00

300.00 2,400.00

192.00 4,608.00

38.00 608.00

313.00 5,008.00

202.00 3,232.00

171.00 2,052.00

43.00 172.00

769.00 3,076.00

As per the drawing it is integrated

with the Acrylic Countertop

41.00 164.00

292.00 2,336.00

Page 593: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 28,432.00

BF 28,432.00

As per Q&A-383, the sink bowl is

integrated with the Acrylic Countertop

166.00 2,656.00

425.00 1,700.00

636.00 2,544.00

11.00 132.00

1526.00 6,104.00

171.00 684.00

458.00 1,832.00

INCLUDED

818.00 818.00

4706.00 4,706.00

INCLUDED

INCLUDED

Page 594: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

21,176.00

US Dollar. 104,388.00

30.00 11,400.00

12.00 14,880.00

Page 595: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 26,280.00

BF 26,280.00

66.00 264.00

85.00 340.00

88.00 704.00

23.00 92.00

26.00 156.00

Page 596: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

133.00 532.00

162.00 3,888.00

Included in Item-2, Section 113000

CF 5,976.00

BF 5,976.00

60.00 240.00

74.00 296.00

74.00 296.00

Page 597: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

74.00 296.00

78.00 312.00

104.00 416.00

45.00 180.00

55.00 220.00

55.00 220.00

55.00 220.00

59.00 236.00

77.00 308.00

139.00 556.00

170.00 680.00

76.00 304.00

44.00 528.00

44.00 704.00

Page 598: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 6,012.00

BF 6,012.00

2277.00 9,108.00

2971.00 11,884.00

2277.00 9,108.00

2277.00 9,108.00

1690.00 6,760.00

2680.00 10,720.00

2945.00 2,945.00

2945.00 2,945.00

Page 599: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 62,578.00

BF 62,578.00

INCLUDED

818.00 818.00

INCLUDED

INCLUDED

INCLUDED

Page 600: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

US Dollar. 101,664.00

9060.00 9,060.00

3118.00 3,118.00

95.00 95.00

180.00 180.00

1646.00 1,646.00

1289.00 1,289.00

773.00 773.00

2090.00 2,090.00

Page 601: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 18,251.00

BF 18,251.00

10209.00 10,209.00

6060.00 6,060.00

2769.00 2,769.00

84.00 84.00

125.00 125.00

1102.00 1,102.00

1063.00 1,063.00

665.00 665.00

1386.00 1,386.00

Page 602: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 23,463.00

BF 23,463.00

4607.00 4,607.00

7754.00 7,754.00

10.00 240.00

Page 603: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 12,601.00

BF 12,601.00

12.00 432.00

20.00 240.00

11.00 132.00

9.00 540.00

19.00 1,140.00

16.00 384.00

16.00 384.00

47.00 1,128.00

204.00 6,528.00

Page 604: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 10,908.00

BF 10,908.00

208.00 11,648.00

110.00 1,760.00

193.00 3,860.00

189.00 4,536.00

110.00 3,520.00

184.00 736.00

102.00 1,632.00

250.00 14,000.00

616.00 22,176.00

222.00 1,776.00

901.00 7,208.00

CF 72,852.00

BF 72,852.00

included

Page 605: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

included

included

included

included

39.00 1,872.00

Page 606: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

US Dollar. 139,947.00

47.00 1,128.00

34.00 408.00

34.00 136.00

34.00 680.00

1736.00 6,944.00

AS PER Q&A # 317 NOT IN THE SCOPE

AS PER Q&A # 317 NOT IN THE SCOPE

10.00 6,800.00

See Master plan BOQ

Page 607: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 16,096.00

BF 16,096.00

209.00 836.00

458.00 1,832.00

109.00 436.00

326.00 2,608.00

10.00 400.00

1084.00 4,336.00

10.00 640.00

68.00 1,632.00

62.00 248.00

97.00 388.00

68.00 272.00

Page 608: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

80.00 960.00

CF 14,588.00

BF 14,588.00

68.00 272.00

3047.00 12,188.00

included in the above

10.00 2,800.00

10.00 1,080.00

included

included

included

Page 609: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

included

included

2914.00 11,656.00

27,996.00

US Dollar. 58,680.00

Page 610: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2.00 1,174.00

3.00 1,761.00

8.00 3,744.00

10.00 220.00

12.00 4,272.00

3.00 2,163.00

4.00 888.00

CF 14,222.00

BF 14,222.00

Page 611: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1.00 721.00

0.00 0.00

721.00

US Dollar 14,943.00

682,991.00

16,070.00

37,784.00

39,580.00

34,944.00

207,577.00

204,346.00

24,556.00

1,860.00

0.00

104,388.00

Page 612: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

101,664.00

139,947.00

58,680.00

14,943.00

1,669,330.00

63,434,540.00

US Dollar 63,434,540.00

Page 613: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Item Nr. Description Unit Qty Rate

03 00 00 - CONCRETE

03 11 13 Structural Cast-in-Place Concrete Forming

1 m3 27 164.00

03 31 00 Structural Concrete

2 Reinforced concrete 35Mpa for strip footing m3 70 380.00

3 Reinforce concrete 35MPa for slab on grade with 7Ø8 / Liner meter thic m3 28 296.00

Precast Concrete

3 Precast Concrete for super structure item 1 348618.00

Concrete Topping

4 Sand cement concrete screed with wire mesh thick 50mm for floors above m2 591 25.00

hollow core slabs.

5 Sand cement foam concrete to slab at roof average 75mm thick m2 191 17.00

6 Sealed Concrete for beds at roof thick 350mm m3 3 376.00

7 Sand cement screed for floors to receive finishing thickness 50mm m2 400 17.00

03 30 53 - Miscellaneous Cast-in-situ Concrete

8 300mm wide x 200mm high reinforced concrete 35 Mpa for lintel m 28 32.00

9 100mm wide x 200mm thick reinforced concrete 35 Mpa for lintel m 18 11.00

Plain concrete 20MPa for blinding thickness 100mm for footing and 50mm under slab on grade

Page 614: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF

Total for CONCRETE

CARRIED TO SUMMARY US Dollar.

04 00 00 - Masonry

04 22 00 - Concrete Unit Masonry

Internal walls and Partitions

1 100mm thick CMU wall non fire rated m2 159 34.00

Total for MASONRY

CARRIED TO SUMMARY US Dollar.

05 00 00 METALS

All metalworks herein shall be completed full incompliance with the Drawings V1-A902

and Specification.

05 12 00 Structural Steel Framing

1 Supply and fix 200mm x 50mm rectangular hollow aluminium powder coate m2 166 163.00

fixed to beam, kind, quality, fittings, fixtures, accessories as per Drawings and as per

Specifications.

05 70 00 Decorative Metal

2 Supply and fix 50mm x 50mm galvanized steel powder coated hand rails fo m 26 226.00

Page 615: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

floor mounted, kind, quality, preservative treatment, fittings, fixtures, accessories,

painting etc. as shown on Drawings and as per specifications.

05 00 00 Metals

Additional Items

3 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Total for METALS

CARRIED TO SUMMARY US Dollar.

06 00 00 WOOD, PLASTICS, AND COMPOSITES

06 41 00 Architectural Wood Casework

1 Supply and fix kitchen under counter cabinets 2700mm long 600mm wide nr 2 3182.00

(counter tops measured separately) at kitchen MDF melamine laminated with aluminum

edge, base & overhead cabinets with polished chrome cabinet pull handles and all other

accessories as per the Drawing nr V2-A905 and Specification.

2 Supply and fix kitchen under counter cabinets 1200mm long 600mm wide nr 4 1420.00

(counter tops measured separately) at kitchen MDF melamine laminated with aluminum

edge, base & overhead cabinets with polished chrome cabinet pull handles and all other

accessories as per the Drawing nr V2-A905 and Specification.

3 Supply and fix laundry under counter cabinets 1200mm long 340mm wide nr 4 3212.00

(counter tops measured separately) at laundry MDF melamine laminated with aluminum

edge, base & overhead cabinets with polished chrome cabinet pull handles and all other

accessories as per the Drawing nr V2-A905 and Specification.

4 Supply and fix kitchen overhead cabinets 1200mm long 400mm wide 800 nr 2 Price Included

(counter tops measured separately) at kitchen MDF melamine laminated with aluminum

edge, base & overhead cabinets with polished chrome cabinet pull handles and all other

accessories as per the Drawing nr V2-A905 and Specification.

5 Supply and fix kitchen overhead cabinets 1900mm long 400mm wide 800 nr 2 Price Included

(counter tops measured separately) at kitchen MDF melamine laminated with aluminum

edge, wall cabinets with polished chrome cabinet pull handles and all other accessories

as per the Drawing nr V2-A905 and Specification

As per Question and Answer No. (89) the kitchen cabinet changed to Aluminum

Page 616: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF

BF

WOOD, PLASTICS, AND COMPOSITES (Cont'd)

06 61 16 Solid Surfacing Fabrications

1 Supply and fix Solid Acrylic counter top shaped 550mm long 420mm wide nr 2 234.00

for wash basin as shown in the Drawing nr V2-A903 and Specification.

2 Supply and fix Solid Acrylic counter top shaped 1520mm long 550mm wide nr 2 496.00

for wash basin as shown in the Drawing nr V2-A903 and Specification.

3 Supply and fix Solid Acrylic counter top shaped 1490mm long 550mm wide nr 2 489.00

for wash basin as shown in the Drawing nr V2-A903 and Specification.

4 Supply and fix Solid Acrylic counter top shaped 2700mm long 600mm wide nr 2 889.00

for kitchen sink as shown in the Drawing nr V2-A903 and Specification.

5 Supply and fix Solid Acrylic counter top shaped 1200mm long 600mm wide nr 4 265.00

shown in the Drawing nr V2-A903 and Specification.

6 Supply and fix Solid Acrylic counter top shaped 1200mm long 340mm wide nr 2 265.00

shown in the Drawing nr V2-A903 and Specification.

7 Supply and fix Solid Acrylic counter top shaped 1070mm long 430mm wide nr 2 335.00

as shown in the Drawing nr V2-A904 and Specification.

06 00 00 Wood, Plastics, and Composites

Additional Items

1 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Total for WOOD, PLASTICS, AND COMPOSITES

CARRIED TO SUMMARY US Dollar.

07 00 00 THERMAL AND MOISTURE PROTECTION

07 10 00 Damp proofing and Waterproofing

Page 617: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Substructure Waterproofing

All works herein shall be completed full incompliance with the Drawings nr V-S002, VS003,

V-S004, V-S005, V-S401 and Specification.

1 Two coats of bitumen paint for sub structure for vertical surface. m2 226 5.00

2 Ditto for horizontal surface m2 158 5.00

3 Waterproofing works for substructure with vapour barrier 250 microns, hori m2 226 2.00

surface as per the Drawings and Specification).

Wet Area Waterproofing / Roof Waterproofing

All works herein shall be completed in full compliance with the Drawings nr V2-A202,V2-

A203, V2-A204, V2-A205,V2-A903, V2-A907 and Specification.

4 m2 90 22.00

5 m2 52 22.00

6 Waterproofing membrane for roof and second floor terrace, horizontal surf m2 180 37.00

300mm, (kind, quality, method of fixing, thickness as per the Drawings and Specification)

7 Geotextile layer for roof and second floor terrace water proofing works, hor m2 180 3.00

surface, width > 300mm, (kind, quality, method of fixing, thickness as per the Drawings

and Specification)

CF

BF

THERMAL AND MOISTURE PROTECTION (Cont'd)

1 100mm thick insulation for water proofing works at roof and second floor t m2 180 23.00

proofing works, horizontal surface, width > 300mm, (kind, quality, method of fixing,

thickness as per the Drawings and Specification)

07 21 13 Board Insulation

2 Anti-vibration insulation, thickness as per the manufacturers requirements m2 9 34.00

bearing at room as per the Drawing nr V-S401 and Specification.

Waterproofing works for wet area, vertical surface, as per the Drawings and Specification

Waterproofing works for wet area, horizontal surface,as per the Drawings and Specification

Page 618: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for THERMAL AND MOISTURE PROTECTION

CARRIED TO SUMMARY US Dollar.

08 00 00 OPENINGS

All works herein shall be completed in full compliance with the Doors & W Note

Schedule Drawings V2-A801, V2-A802, V2-A803 and Specification.

08 13 00 - Metal Doors

As per Question and Answer No (420)

1 Supply and fix steel flush decorative veneer door, 50mm thick, 2360mm nr 2 3639.00

high with 6mm low glass +16+6mm clear glass vision panel including steel frame, type

D1, finished with and including paint, all accessories and hardware including but not

limited to hinges HDH type, outside door lock, lever handle and latch, wall stop, roses

and escutcheons as stated in the Specification.

08 14 00 - Wood Doors

2 Supply and fix wooden flush door, 44mm thick, 900mm wide x 2200mm hig nr 8 953.00

frame, type D2, finished with and including paint all accessories and hardware including

but not limited to hinges BBS type, door stopper, inside door lock, lever handle and latch,

wall stop, roses and escutcheons as stated in the Specification.

3 Supply and fix wooden flush door, 44mm thick, 800mm wide x 2200mm hig nr 8 952.00

frame, type D3, finished with and including paint all accessories and hardware including

but not limited to hinges BBS type, door stopper, outside door lock, lever handle and

latch, wall stop, roses and escutcheons as stated in the Specification.

08 51 00 Aluminum Windows

4 Supply and fix aluminium window, 4200mm wide x 2700mm high doubled nr 1 6660.00

with open glass door window including frame, type W1, all accessories and hardware

including but not limited to hinges, handle, lock,weather tight strip etc. as stated in the

Drawings and Specification.

Page 619: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF

BF

OPENINGS (Cont'd)

1 Supply and fix aluminium window, 2800mm wide x 2700mm high aluminium nr 2 5537.00

shutters 1385mm x 2700mm, in front sliding glass panel including frame, type W2, all

accessories and hardware including but not limited to hinges, handle, lock,weather tight

strip etc. as stated in the Drawings and Specification.

2 Supply and fix aluminium window, 4200mm wide x 750mm high, doubled nr 2 1940.00

including frame, type W3, all accessories and hardware including but not limited to

hinges, weather tight strip etc. as stated in the Drawings and Specification.

3 Supply and fix aluminium window, 600mm wide x 1500mm high doubled g nr 10 633.00

including frame, type W4, all accessories and hardware including but not limited to

hinges, handle, lock,weather tight strip etc. as stated in the Drawings and Specification.

hinges, handle, lock, weather tight strip etc. as stated in the Drawings and Specification.

5 Supply and fix aluminium window, 300mm wide x 2700mm high, doubled g nr 2 497.00

including frame, type W5, all accessories and hardware including but not limited to

hinges, weather tight strip etc. as stated in the Drawings and Specification.

6 Supply and fix aluminium window, 300mm wide x 2700mm high, doubled gl nr 2 565.00

type W5a, all accessories and hardware including but not limited to hinges, handle,

lock,weather tight strip etc. as stated in the Drawings and Specification.

Page 620: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

7 Supply and fix aluminium window, 4200mm wide x 2700mm high aluminium nr 2 8825.00

shutters 1365mm x 2700mm, in front sliding glass panel including frame, type W6, all

accessories and hardware including but not limited to hinges, handle, lock,weather tight

strip etc. as stated in the Drawings and Specification.

8 Supply and fix aluminium window, 4200mm wide x 2700mm high aluminium nr 2 8324.00

shutters 1950mm x 2700mm, in front sliding glass panel including frame, type W7, all

accessories and hardware including but not limited to hinges, handle, lock,weather tight

strip etc. as stated in the Drawings and Specification.

9 Supply and fix aluminium window, 2000mm wide x 2700mm high, doubled nr 2 1554.00

including frame, type W8, all accessories and hardware including but not limited to

hinges, weather tight strip etc. as stated in the Drawings and Specification.

CF

BF

OPENINGS (Cont'd)

1 Supply and fix aluminium window, 1220mm wide x 750mm high, doubled g nr 2 362.00

including frame, type W9, all accessories and hardware including but not limited to

hinges, weather tight strip etc. as stated in the Drawings and Specification.

Page 621: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2 Supply and fix aluminium window, 2000mm wide x 750mm high, doubled g nr 4 971.00

including frame, type W10, all accessories and hardware including but not limited to

hinges, handle, lock,weather tight strip etc. as stated in the Drawings and Specification.

08 83 00 Mirrors

3 Supply and fix fixed mirror 1465mm width x 1050mm high for bathrooms (si nr 2 132.00

quality, surface treatment, method of jointing etc. as per the Drawings nr V2-903 and

Specification).

4 Supply and fix fixed mirror 550mm width x 1050mm high for bathrooms ( si nr 2 82.00

quality, surface treatment, method of jointing, etc. as per the Drawings nr V2-903 and

Specification).

5 Supply and fix fixed mirror 1515mm width x 1050mm high for bathrooms ( s nr 2 137.00

quality, surface treatment, method of jointing, etc. as per the Drawings nr V2-903 and

Specification).

08 91 19 Fixed Louvers

6 Supply and fix fixed exhaust fan louver (size, kind, quality, preservative tr nr 6 626.00

surface treatment, method of jointing, etc. as per the Drawings and Specification).

CF

BF

OPENINGS (Cont'd)

08 00 00 Openings

Additional Items

1 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

1.1 lm 22 305.00

1.2 M² 723.00

As per Question and Answer No. (544) toughened laminated glass balustrade behind shutter where applicable

As per Question and Answer No. (531) Electrically Operated Sliding Shutter System (OPTIONAL)

Page 622: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for OPENINGS

CARRIED TO SUMMARY US Dollar.

09 00 00 - FINISHES

09 23 00 Gypsum Board wall

1 Gypsum wall above wooden cabinet closet m2 16 55.00

09 24 00 Cement Plastering

2 15mm thick internal Plastering for block walls to receive paint m2 421 22.00

3 Ditto for walls to receive tiling at wet areas, m2 93 21.00

CF

BF

FINISHES (Cont'd)

09 30 13 Ceramic Tiling

Floor Tiling

1 Porcelain tile flooring (type - FT1), size 600mm x 600mm, m2 364 55.00

2 Porcelain tiles(FT5), size 600 x 600mm for balcony m2 11 51.00

3 Terrazo tiles(FT9), size 400 x 400mm at roof and water tank area m2 164 32.00

Wall tiling

5 Mosaic tile (type WT4) 100mm x 300mm size for kitchen walls, m2 60 53.00

4 Porcelain tile (WT1), 325mm x 977mm size for toilets and bathrooms walls m2 122 72.00

As per client Question and Answer No. 63, the balcony floor finish is changed to porcelain tiles FT5

As per client Question and Answer No. 89 wall finish at back of Kitchen Cabinets is Render

Page 623: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Skirting

As per client Question and Answer No 293, the height for skirting 100mm

1 MDF skirting 100mm height, m 184 17.00

2 Pocelain tile skirting 100mm height, for kitchen and laundry, m 32 17.00

3 As per (Q&A) no. 63 the skirting for stair case changed to porcelain 100m m 81 19.00

Stair Finish

4 Porcelain tile tread including bull nose (type - FT1), 280mm wide x 1100m m 100 24.00

5 Porcelain tile for riser (type - FT1), 160mm high x 1100mm length, m 94 20.00

CF

BF

FINISHES (Cont'd)

09 50 00 Ceilings

1 Supply and install gypsum ceiling, depth of suspension 500 - 1000 mm m2 192 54.00

as per the Drawings nr V1-A906,V1-A901

2 m2 20 56.00

3 m2 30 56.00

09 91 00 - Painting

Wall -Painting

3 Painting for internal walls, m2 579 11.00

Supply and install 16mm thick gypsum ceiling for kitchen area depth of suspension 500-1000mm as per drawing nr. V2-A906, V2-A901

Supply and install 16mm thick moisture resistant gypsum ceiling for toilet and baathroom depth of suspension 500-1000mm as per drawing nr. V2-A906, V2-A901

Page 624: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

4 Painting for walls in staircases, m2 220 11.00

Ceiling -Painting

5 Painting for ceiling, m2 160 11.00

6 Painting for staircase ceiling, m2 70 11.00

.

7 Painting for gypsum board ceiling m2 242 11.00

CF

Total for FINISHES

CARRIED TO SUMMARY US Dollar.

10 00 00 SPECIALTIES

10 22 23 Portable Partitions, Screens, and Panels

1 Supply and fix shower screen 8mm thick tempered glass 1000mm x 2000 nr 2 582.00

partition, finished, all accessories and hardware including but not limited to hinges,

handle etc. as stated in the Drawing nr V2-A903 and Specification

2 Supply and fix shower screen 8mm thick tempered glass 870mm x 1600m nr 2 527.00

partition, finished, all accessories and hardware including but not limited to hinges,

handle, etc. as stated in the Drawing nr A2-A903 and Specification

10 28 00 –Toilet, Bath and Laundry Accessories

Supply & install Plumbing Fixtures as shown in Drawing nr V2-A903 and Technical

Specification including all accessories, fittings , flexible connections etc.

3 Tissue paper holder(TPH nr 6 21.00

4 Soap dispenser (SD) nr 6 22.00

5 Towel bar nr 6 31.00

6 Towel ring nr 6 35.00

7 Robe hook nr 6 17.00

Page 625: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF

BF

SPECIALTIES (Cont'd)

10 44 13.13 Portable Fire Extinguishers

All items hereunder to be described with , kind, quality, size, method of fixing , etc. as per

the Drawings and Specification).

1 Supply & install Portable Fire Extinguishers nr 2 54.00

2 Supply & install fire blanket nr 2 76.00

10 57 00 Wardrobe and Closet Specialties

3 Supply and fix wardrobe 3100 mm length, 600mm wide, 2400mm high, wi nr 4 2168.00

laminated dark wood veneer shelves, door with MDF white matt lacquer finish and

chromed stainless steel handles, and all other accessories as per the Drawing nr V2-A201,

A201B, A904 and Specification.

4 Supply and fix wardrobe 3700 mm length, 600mm wide, 2400mm high, wi nr 2 2588.00

laminated dark wood veneer shelves, door with MDF white matt lacquer finish and

chromed stainless steel handles, and all other accessories as per the Drawing nr V2-A201,

A201B, A904 and Specification.

5 Supply and fix closets 2100 mm length, 500mm depth, 2400mm high, wit nr 2 1469.00

laminated dark wood veneer shelves, door with MDF white matt lacquer finish and

chromed stainless steel handles, and all other accessories as per the Drawing nr V2-A201,

A201B, A905 and Specification.

6 Supply and fix pantry 1600 mm length, 600mm depth, 2400mm high, with nr 2 1119.00

laminated dark wood veneer shelves, door with MDF melamine laminated with

aluminium edge banding finish and polished chromed stainless steel handles, and all

other accessories at pantry as per the Drawing nr V2-A905 and Specification.

7 Supply and fix closets 2120 mm length, 600mm depth, 900mm high with b nr 2

MDF laminated, door with MDF melamine laminated with aluminium edge banding finish

and polished chromed stainless steel handles, and all other accessories at cloakroom as

per the Drawing nr V2-A905 and Specification

8 Supply and fix closets 1070 mm length, 550mm depth, 2400mm high with nr 2 749.00

MDF laminated, door with MDF melamine laminated with aluminium edge banding finish

and polished chromed stainless steel handles, and all other accessories at cloakroom as

per the Drawing nr V2-A201, A905 and Specification

9 Supply and fix under counter cabinet 1070 mm length, 430mm depth, 900 nr 2 included

Page 626: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

base cabinet MDF laminated, door with MDF melamine laminated with aluminium edge

banding finish and polished chromed stainless steel handles, and all other accessories at

cloakroom as per the Drawing nr V2-A201, A905 and Specification

10 Supply and fix library shelving unit, 1760 mm length, 340mm depth, 240 nr 2 1231.00

with white matt laquer finish, and all other accessories, as per the Drawing nr V2-A904

detail 5 and 6, and Specification

CF

BF

SPECIALTIES (Cont'd)

10 00 00 Specialties

Additional Items

1 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

1.01 Towel Pin nr 6 17.00

Page 627: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for SPECIALTIES

CARRIED TO SUMMARY US Dollar.

11 00 00 EQUIPMENT

All items hereunder to be described with information such as appropriate to the

procurement , design, supply, execution, type, kind, quality, size, method of fixing ,

specified codes of practice, etc. as per the Drawings and Specification).

11 30 00 Residential Equipment

AS PER Q&A-77 NOT INCLUDED

1 Refrigerator/freezer nr 2IN THE SCOPE OF WORKS

2 Exhaust hoods nr 2 465.00

AS PER Q&A-77 NOT INCLUDED

3 Cooker nr 2IN THE SCOPE OF WORKS

AS PER Q&A-77 NOT INCLUDED

4 Washing Machine nr 2IN THE SCOPE OF WORKS

11 00 00 Equipment

Additional Items

5 The Contractor is to list here and price any items shown on the Drawings, Item

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Total for EQUIPMENT

CARRIED TO SUMMARY US Dollar.

12 00 00 FURNISHING

All items hereunder to be described with information such as appropriate to the

procurement , design, supply, execution, type, kind, quality, size, method of fixing ,

specified codes of practice, etc. as per the Drawings and Specification).

12 00 00 Furnishing

Additional Items

1 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Page 628: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for FURNISHING

CARRIED TO SUMMARY US Dollar.

22 00 00 - PLUMBING

All items hereunder to be described specified code of practice and regulations, kind,

quality, size, method of fixing , finishes or surface treatments, etc. as per the Drawings

and Specification).

22 05 23 General-Duty Valves for Plumbing Piping

Valves

Valves are classified according to type . Material and/or size . Rates include furnishing

and installing of valves, testing at manufacturer's premises and on site; diameters of

valves and water meter according to pipe diameter which will be connected with it; as

per Drawings and Specfication.

Gate Valve

1 25 mm diam. nr 6 25.00

2 32 mm diam. nr 8 34.00

3 40 mm diam. nr 20 48.00

Angle Valve

4 20 mm diam. nr 20included in sanitary fixture section 224000

5 25 mm diam. nr 6included in sanitary fixture section 224000

Globe Valve

6 20 mm diam. nr 4 68.00

7 25 mm diam. nr 6 72.00

8 32 mm diam. nr 2 110.00

Non-Return Valve

9 20 mm diam. nr 4 20.00

10 25 mm diam. nr 6 23.00

11 40 mm diam. nr 4 50.00

Pressure Reducing Valve

Page 629: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

12 40 mm diam. nr 2 210.00

CF

BF

22 11 16 Domestic Water Piping

Domestic water piping is classified by material and diameter. Rates include furnishing

and installing of pipes, fittings, accessories, fixing supprts, joints, sleeves, special parts,

connections, hanger supports. Rates to include all works and materials necessary for

complete installation for piping system as per the Drawings and Specfication.

Water Supply System

1-Cold Water Supply

1 20 mm diameter. m 62 16.00

2 25 mm diameter. m 68 19.00

3 32 mm diameter. m 24 21.00

4 40 mm diameter. m 70 35.00

2-Hot Water Supply

5 20 mm diameter. m 80 19.00

3 - Accessories

6 Hose Bibb 20mm . nr 4 29.00

7 Water Meter 40 mm. nr 2 1576.00

8 Water Hammer Arrestor nr 8 46.00

Page 630: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

9 Automatic Air Vent. nr 4 96.00

10 Pressure Gauge . nr 4 46.00

11 Strainer 40 mm. nr 2 79.00

CF

BF

PLUMBING (Cont'd)

22 13 16 Sanitary Waste and Vent Piping

Sanitary Pipe Works

Sanitary pipe works is classified by material and diameter. Rates include furnishing and

installing of pipes, fittings, accessories, fixing supprt, joints, sleeves , special parts,

connections, hanger supports. Rates for pipework below ground also include excavation,

backfilling , civil work, trenches and any other accessories or fittings necessary for

complete installation of the piping system.Testing of pipes at the manufacturer's

premises is included.All as per the Drawings and Specfication.

Page 631: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Pipes and fitting above ground

Waste Pipe

1 50 mm diameter. m 20 11.00

2 75 mm diameter. m 24 17.00

3 110 mm diameter. m 30 29.00

Soil Pipe

4 110 mm diameter. m 20 29.00

Pipes and fitting below ground

5 75 mm diameter. m 16 27.00

6 110 mm diameter. m 28 36.00

Soil Pipe

7 110 mm diameter. m 12 36.00

Vent Pipe Works

Vent pipes are classified by material and diameter. Rates include furnishing and installing

of pipes, fittings, accessories, fixing supprt, joints, sleeves, special parts, connections,

hanger supports. Rates include furnishing and installing of pipes, fittings, accessories,

fixing supprt, joints, sleeves , special parts, connections, hanger supports. Rates for

pipework below ground also include excavation, backfilling , civil work, trenches and any

other accessories or fittings necessary for complete installation of the piping

system.Testing of pipes at the manufacturer's premises is included.All as per the

Drawings and Specfication.

Pipes and fittings above ground

8 75 mm diameter. m 50 17.00

Page 632: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF

BF

PLUMBING (Cont'd)

Pipes and fitting below ground

1 75 mm diameter. m 10 27.00

22 13 19.13 Sanitary Drains

Sanitary drains (to include rainwater pipework and condensate drain pipework) are

classified by material and diameter. Rates include furnishing and installing of pipes,

fittings, accessories, fixing supports, joints, sleeves, special parts, connections, hanger

supports. Rates also include testing of pipes at the manufacturer's premises. All as per

the Drawings and specfication.

Rain water Pipe

2 75 mm diameter. m 32 17.00

Condensate Drain Pipe Works

3 20 mm diameter. m 28 9.00

22 33 00 Electric Domestic Water Heaters

Electric domestic water heaters are classified according to capacity. Rates include

furnishing of heater complete with safety valves, air vent, pressure and tempearture

relief gauges, drain valves, all valves set (angle, gate, non return, etc .), thermostat,

heating element, contactors, switch, support, bolts, nuts, connection of pipes, testing on

site, commissioning and putting into service.

4 EWH-V2-01 with (30 liters / 1200 W) capacity. nr 4 275.00

5 EWH-V2-02 with (80 liters / 1200 W) capacity. nr 4 300.00

6 EWH-V2-03 with (100 liters / 1500 W) capacity. nr 2 322.00

22 40 00 Plumbing Fixtures

All items described hereunder to be of kind, quality, size, nature of base, method of

fixing, complete with accessories etc. as per the Drawings nr V2-903 and Specification

7 Floor Drain (FD) nr 10 192.00

8 Flexible Shower Hose nr 6 38.00

Page 633: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

9 Water Closet nr 6 313.00

CF

BF

PLUMBING (Cont'd)

1 Floor clean out nr 2 202.00

2 Roof drain nr 6 171.00

3 Vent cap nr 2 43.00

4 Bath tub (BT) including taps, plug, accessories and fitting. nr 2 769.00

As per the drawing it is integrated

5 Wash basin (WB) nr 6with the Acrylic Countertop

As per Q&A no. 358 clothes washer not in contract, only connections

6 Washing machine connections (washing machine not in contract) nr 2 41.00

As per Q&A no. 360 shower channel to be used

7 Shower (SHO) including shower channel, mixer tap, fitting, spray and adju nr 2 292.00

As per Q&A-383, the sink bowl is

8 Kitchen sink nr 2integrated with the Acrylic Countertop

9 Taps for wash basin including fittings , plugs, valves, connections and was nr 6 166.00

10 Mixer tap for kitchen sink including fitting, plugs, chrome plated pipes, val nr 2 425.00

waste

Page 634: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF

BF

PLUMBING (Cont'd)

22 00 00 - Plumbing

Additional Items

1 Inspection chamber as per Drawings and Specification; connected directly nr 2 636.00

sewer network.

2 Clean out (CO) nr 4 11.00

3 Roof Water tank as per Specification; rate shall be include supplying and in nr 2 1526.00

all fittings, accessories, valves, pipework, vents etc. as per the Drawings and

Specification

4 Gully Trap nr 2 458.00

The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Additional Items

5 Marking the position of holes, mortices and chases in the structure Item 1 included

6 Identification; plates, discs, labels, tapes, bands, arrows, symbols, letter Item 1 410.00

charts; as stated on drawings and in Specification

7 Testing and commissioning of entire installation Item 1 2048.00

8 Preparation of as-built drawings Item 1 included

9 Preparation of operation and maintenance manuals Item 1 included

10 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

10.1 Gate Valve, 20 mm diam. nr 4 20.00

Page 635: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for PLUMBING

CARRIED TO SUMMARY US Dollar.

23 00 00 - HEATING, VENTILATING, AND AIR CONDITIONING (HVAC)

All HVAC works shall be completed as per the Drawings and Specification.

23 23 00 Refrigerant Piping

Supply and fix refrigerant pipes for FCU from condensing units to indoor installed AC

units including fittings, sleeves and all accessories as per the Drawings and Specification

1 20 mm diameter with max liquid line 10 mm. m 130 30.00

23 31 00 HVAC Ducts and Casings

All items described hereunder to be of type, kind, quality, size, method of fixing, specified

codes of practice, method of fixing/supports, etc. as per the Drawings and Specification

Notwithstanding the provisions of the Standard Method of Measurement, in Note

ductwork is to include insulation to the ductwork. No claim for additional cost due to lack

or want of knowledge will be entertained

Page 636: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2 Supply and fix insulated indoor galvanized steel sheet metal duct work fo Kg 450 12.00

as specified and as indicating on drawings, complete with bends, supports, connections,

fittings, splices and all accessories to complete the work.

CF

BF

HEATING, VENTILATING, AND AIR CONDITIONING (Cont'd)

23 33 13.13 Volume-Control Dampers

All items described hereunder to be of type, kind, quality, size, method of fixing, specified

codes of practice, etc. as per the Drawings and Specification

Volume Dampers

1 Volume Damper ; 200 mm dia. circular damper nr 2 66.00

2 Volume Damper ; 250 mm dia. circular damper. nr 2 76.00

3 Volume Damper ; 300 mm dia. circular damper. nr 2 85.00

23 33 46 Flexible Ducts

All items described hereunder to be of type, kind, quality, size, method of fixing, specified

codes of practice, etc. as per the Drawings and Specification

4 Supply and install Flexible duct with insulation ; size 200 mm dia. m 4 23.00

5 Supply and install Flexible duct with insulation ; size 250 mm dia. m 2 25.00

6 Supply and install flexible duct with insulation; size 300 mm dia. m 2 26.00

23 34 00 HVAC Fans

All items described hereunder to be of capacity, design, supply, execution, type, kind,

quality, size, method of fixing , specified codes of practice, etc. as per the Drawings and

Specification

Supply and install exhaust fan as specified and as indicated in drawing. Fan consists of

casing, fan, motor, control, filter, sand trap louver, all electrical works (compenents,

wiring, switches etc.) and all accessories. Electrical power supply 220/1/60.

Wall Mounted

7 Exhaust Fan (EF-01) 40 Pa with total air flow 50 L/S . nr 2 133.00

Page 637: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Ceiling Mounted

8 Exhaust Fan (EF-02 to EF-06)) 100 Pa with total air flow 25 L/S . nr 10 162.00

Range Hood Fan

9 Range Hood Fan (RH-01) ;150 Pa with total air flow 50 L/S . nr 2As per Q&A-361 item is deleted

CF

BF

HEATING, VENTILATING, AND AIR CONDITIONING (Cont'd)

23 37 00 Air outlets and Inlets

All items described hereunder to be of type, kind, quality, size, method of fixing, specified

codes of practice, etc. as per the Drawings and Specification

Supply and install Painted Supply linear bar air Register with complete accessories.as per

the Drawings and Specification.

1 Size 700x150 mm ;260 L / s . nr 2 67.00

2 Size 700x150 mm ;265 L / s . nr 2 67.00

3 Size 800x150 mm ; 295 L / s. nr 2 74.00

4 Size 1000x150 mm ; 365 L / s. nr 4 101.00

Supply and install Painted Return linear bar air grille with complete accessories.as per the

Drawings and Specification.

Page 638: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

5 Size 700x150 mm ;260 L / s . nr 2 50.00

6 Size 700x150 mm ;265 L / s . nr 2 50.00

7 Size 800x150 mm ; 295 L / s. nr 2 55.00

8 Size 1000x150 mm ; 365 L / s. nr 2 75.00

Supply and install 3 way Supply ceiling diffuser with complete accessories.as per the

Drawings and Specification.

9 Size 375X375 mm ; 100 L/s. nr 2 139.00

10 Size 375X375 mm ; 115 L/s. nr 2 139.00

11 Size 450X450 mm ; 210 L / s. nr 2 170.00

Supply and install 4 way Return ceiling diffuser with complete accessories.as per the

Drawings and Specification.

12 Size 375X375 mm ; 115 L/s. nr 2 64.00

13 Size 375X375 mm . nr 2 64.00

14 Size 450X450 mm; 183 L/s. nr 4 76.00

15 Size 450X450 mm; 210 L/s. nr 2 76.00

Exhaust air louver

16 Exhaust air louver (250X100)mm. nr 2 44.00

17 Exhaust air louver (250X150)mm. nr 12 44.00

CF

BF

HEATING, VENTILATING, AND AIR CONDITIONING (Cont'd)

23 82 00 Convection Heating and Cooling Units

Page 639: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

All items described hereunder to be of capacity, design, supply, execution, type, kind,

quality, size, method of fixing , specified codes of practice, etc. as per the Drawings and

Specification

Supply and install concealed fan coil unit as specified and as indicated in drawing. Unit to

be complete with air cooled condensing unit, fan, filter, valves, controls, thermostat, all

electrical works (compenents, wiring, switches etc.) and all accessories. Electrical power

supply 220/1/60.

1 (FCU-01) , 570 L / s , 50 Pa ; Electrical data power 4.5 KW . nr 2 2971.00

2 (FCU-02) , 365 L / s , 50 Pa ; Electrical data power 4 KW . nr 2 2277.00

3 (FCU-03) , 295 L / s , 50 Pa ; Electrical data power 3 KW . nr 2 2277.00

4 (FCU-04) , 480 L / s , 50 Pa ; Electrical data power 4 KW . nr 2 2680.00

5 (FCU-05) , 265 L / s , 50 Pa ; Electrical data power 3 KW . nr 2 2277.00

23 05 93 Testing, Adjusting and Balancing for HVAC

All items hereunder to be described with type of installation, preparatory operations,

stages of test (nr), required attendance, applicable codes etc. as per the Drawings and

Specification).

6 Air balancing of the ducting network Item 1 1227.00

7 Testing, balancing and commissioning of all the equipment Item 1 1227.00

CF

BF

HEATING, VENTILATING, AND AIR CONDITIONING (Cont'd)

23 00 00 - Heating, Ventilating, and Air Conditioning (HVAC)

Additional Items

1 Marking the position of holes, mortices and chases in the structure Item 1 INCLUDED

2 Identification; plates, discs, labels, tapes, bands, arrows, symbols, letter Item 1 205.00

charts; as stated on drawings and in Specification

Page 640: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3 Testing and commissioning of entire installation Item 1 INCLUDED

4 Preparation of as-built drawings Item 1 INCLUDED

5 Preparation of operation and maintenance manuals Item 1 INCLUDED

6 The Contractor is to list here and price any items shown on the Drawings, Item

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Total for HVAC

CARRIED TO SUMMARY US Dollar.

26 00 00 - ELECTRICAL

All works hereunder shall be completed as per the Drawings and Specification.

26 05 19 Low Voltage Electrical Power Conductors and cables

All items hereunder to be of type, kind, number of cores, armoring and sheathings,

method of fixing , specified codes of practice, etc. as per the Drawings and Specification).

Notwithstanding the Provisions of the method of measurement, cables have been

itemised and referenced to the circuit. The contractor is to make due reference to

drawings nrs E000, E001, E002, E003, EL201, EL202, EP201, EP202, LP201, LP202, LP203,

PS301, PS302 MD401, MD402 and MD403 for full details and is to allow for all cabling,

junctions, flexible connections, feeder units etc. required to complete the in Note

accordance with the drawings and Specification. No claim for want or lack of knowledge

will be entertained

1 Lighting circuits Item 1 3581.00

2 Power circuits Item 1 1229.00

3 Fire alarm circuits Item 1 48.00

4 Cooker circuits Item 1 90.00

5 Water heater circuits Item 1 686.00

Page 641: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

6 Fan circuits Item 1 537.00

7 HVAC control circuits Item 1 871.00

CF

BF

ELECTRICAL (Cont'd)

26 05 26 Grounding and Bonding for Electrical Systems

All items hereunder to be described with information such as type, kind, number of

cores, armoring and sheathings, method of fixing , specified codes of practice, etc. as per

the Drawings and Specification).

1 grounding system Item 1 4353.00

26 05 33.13 Conduit for Electrical Systems

All items hereunder to be described with information such as type, kind, method of

fixing , specified codes of practice, etc. as per the Drawings and Specification).

Notwithstanding the Provisions of the method of measurement, conduits have been

itemised and referenced to the circuit. The contractor is to make due reference to

drawings nrs E000, E001, E002, E003, EL201, EL202, EP201, EP202, LP201, LP202, LP203,

PS301, PS302 MD401, MD402 and MD403 for full details and is to allow for all tracking,

fixings, type, size, materials, boxes, connections etc. required to complete the installation

in accordance with the drawings and Specification. No claim for want or lack of

knowledge will be entertained

2 Lighting circuits Item 1 2395.00

3 Power circuits Item 1 1091.00

4 Fire alarm circuits Item 1 42.00

5 Cooker circuits Item 1 63.00

6 Water heater circuits Item 1 460.00

7 Fan circuits Item 1 443.00

Page 642: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF

BF

ELECTRICAL (Cont'd)

1 HVAC control circuits Item 1 578.00

26 24 13 Switchboards

2 All items hereunder to be described with information such as type, kind, rated capacity,

method of fixing, cores reference to Specification, fuses, backgroung,specified codes of

practice, etc. as per the Drawings and Specification).

26 24 16 Panel boards

All items hereunder to be described with information such as type, kind, rated capacity,

method of fixing, cores reference to Specification, fuses, backgroung,specified codes of

practice, etc. as per the Drawings and Specification).

3 Distribution and panel boards Item 1 2304.00

26 27 13 Electricity Metering

4 All items hereunder to be described with information such as type, kind, ra Item 1 3325.00

method of fixing, cores reference to Specification, fuses, backgroung,specified codes of

practice, etc. as per the Drawings and Specification).

26 27 26 Wiring Devices

Notwithstanding the Provisions of the Method of Measurement, wiring devices shall

include final circuits. No claim for lack or want of knowledge shall be entertained

Page 643: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF

BF

ELECTRICAL (Cont'd)

Switches & Push Buttons

All items hereunder to be described with information such as appropriate to the

procurement , type, kind, quality, size, method of fixing , specified codes of practice, etc.

as per the Drawings and Specification).

1 One way one gang switch nr 18 10.00

2 One way two gang switch nr 4 12.00

4 Two way one gang switch nr 2 11.00

Power Outlets

5 Single receptacle 15A 220V 3-wire nr 14 9.00

6 Double receptacle 15A 220V 2 pole 3-wire nr 28 19.00

7 1 way 20A 2P 230v switch with pilot light nr 10 16.00

8 Fusible disconnect switch, double poles, 20A, 230V, with lamp Indicator nr 10 16.00

9 Non-fusable disconnect switch, 1 phase nr 10 47.00

26 50 00 Lighting

Notwithstanding the Provisions of the Method of Measurement, lighting sha Note

final circuits. No claim for lack or want of knowledge shall be entertained

All items hereunder to be described with information such as appropriate to the

procurement , type, kind, quality, size, method of fixing , specified codes of practice, etc.

as per the Drawings and Specification).

10 Luminaries, downlight, multi-mounting, 1 x 26W CFL; type D1 nr 18 204.00

Page 644: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF

BF

ELECTRICAL (Cont'd)

1 Luminaries, down light, multi-mounting, 2 x 26W CFL; type D2 nr 20 208.00

2 Luminaries, down light, recessed-mounting, 2 x 26W CFL; compact lamp 2 nr 24 110.00

D3

3 Luminaires, downlight recessed- mounting; 2 x 42W CFL nr 8 225.00

4 Luminaire, ceiling mounted, square shape; 4 x 18W, 220V, 60hz; type B2 nr 6 193.00

5 Luminaire, down light square shaped, 1 nr x 18W, 220V, 60hz; type S2 nr 6 189.00

6 Luminaire, ceiling mounted, round shaped; 1 x 18W, 220V, 60hz; type R2 nr 6 110.00

7 Luminaire, wall mounted, satin steel/nickel/plastic, white; 1 x 13W, 12V; t nr 4 184.00

8 Luminaire, wall mounted, satin steel/nickel/plastic, white; 1 x 18W, CPL; nr 6 102.00

9 Luminaire, wall mounted, satin steel/nickel/plastic, white; 1 x 2W, CPL; ty nr 32 250.00

10 Luminaire, wall mounted; 1 x 26W CPL, outdoor; type W7 nr 6 222.00

11 Luminaire, bollard type including bollard; HPF, HF electronic ballast with o nr 6 901.00

diffuser; 220V, outdoor; type LS2

CF

BF

ELECTRICAL (Cont'd)

26 00 00 - Electrical

Additional Items

1 Marking the position of holes, mortices and chases in the structure Item 1 included

2 Identification; plates, discs, labels, tapes, bands, arrows, symbols, letter Item 1 included

Page 645: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

charts; as stated on drawings and in Specification

3 Testing and commissioning of entire installation Item 1 included

4 Preparation of as-built drawings Item 1 included

5 Preparation of operation and maintenance manuals Item 1 included

6 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

6.01 Outdoor luminaire, rectangular shape, wall mounted, 1x4W CPL, type W6 nr 4 616.00

6.02 One way three gang switch nr 4 20.00

6.03 Shaver Outlet nr 2 92.00

6.04 Double receptacle 15A 220V 2 pole 3-wire WP nr 2 58.00

6.05 m 20 39.00

Total for ELECTRICAL

CARRIED TO SUMMARY US Dollar.

27 00 00 COMMUNICATIONS

Telecommunication / Low Current Note

STRUCTURED CABLING SYSTEM

Supply, Install, Test, connect and commission inclusive of all cabling, conduits and

containment, socket outlets, all in accordance with the relevant service provider regulations ,

rules, recommendation and requirements and in accordance with the specifications and

drawings.

4C 50mm² CU/XLPE/PVC+25mm² CU/PVC E (Cable from kWH meter to DB) (As per Q&A # 537)

Page 646: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1 Information Outlet, Flush Type 1 DATA, 1 Telephone 0.3 Meters A.F.F.L. nr 12 47.00

2 Telephone Outlet, Wall Mounted Flush Type, MTD 0.30m A.F.F.L nr 6 34.00

3 Telephone Outlet, Wall Mounted, Flush Type 1.2 Meters A.F.F.L. nr 2 34.00

4 TV outlet, wall mounted nr 10 34.00

5 9U Telecom Cabinet, Wall Mounted nr 2 1131.00

6 Set Top Box nr 10AS PER Q&A # 317 NOT IN THE SCOPE

7 LED TV nr 10AS PER Q&A # 317 NOT IN THE SCOPE

8 CAT 6A, UTP Cable m 340 10.00

9 Single Mode Fiber Optic Cable - 1 x 4 Core m See Master plan BOQ

CF

BF

Video Entry System / Intercom

Supply, Install, Test, connect and commission inclusive of all cabling, conduits and

containment, socket outlets, all in accordance with the relevant service provider regulations ,

rules, recommendation and requirements and in accordance with the specifications and

drawings.

1 Entrance Video Door Station nr 2 209.00

2 Residential Main Station nr 2 458.00

3 Door release 12V nr 2 109.00

4 Wireless Handset nr 4 326.00

5 CAT 6A, UTP Cable m 20 11.00

Consumption Metering

Supply, Install, Test, connect and commission inclusive of all cabling, conduits and

containment, socket outlets, all in accordance with the relevant service provider regulations ,

rules, recommendation and requirements and in accordance with the specifications and

drawings.

Page 647: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

6 Metering Receiver nr 2 1084.00

7 M-bus Cable, 2 x 18AWG m 32 9.00

Fire Alarm System

Supply, install, connection, testing and commisioning of wiring and equipment for Fire Alarm

System including all necessary materials and accessories to reflect complete system

installation as per the drawing and specification

8 Addressable, smoke detector nr 16 68.00

9 Addressable, heat detector nr 2 62.00

10 Multisensor Detector nr 2 97.00

11 Addressable, Manual Pull Station nr 2 68.00

12 Sounder / Fire Alarm Bell / Horn nr 6 80.00

CF

BF

1 Control Module nr 2 68.00

2 Fire Alarm Control Panel nr 2 3047.00

3 Power Supply Unit, 24v nr 2 included in the above

4 Loop Cable, 2x1.5mm2 Fire Resistant m 140 10.00

5 24V Cable, 2x2.5mm2 Fire Resistant m 54 10.00

Additional Items

6 Marking the position of holes, mortises and chases in the structure Item 1 included

7 Identification; plates, discs, labels, tapes, bands, arrows, symbols, letter Item 1 included

charts; as stated on drawings and in Specification

8 Testing and commissioning of entire installation Item 1 included

9 Preparation of as-built drawings Item 1 included

10 Preparation of operation and maintenance manuals Item 1 included

Page 648: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

11 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

ADDITIONAL (As per Q&A 487)

1 nr 2 2914.00

Total for COMMUNICATIONS

CARRIED TO SUMMARY US Dollar.

31 00 00 EARTHWORK

All works herein shall be completed in full compliance with the Drawings nr V2-S001,V2-

S002,V2-S003,V2-S004,V2-S005,V2-S2-401and Specification.

31 10 00 Site Clearing

1 Site preparation, clearing site vegetation m2 272 2.00

31 23 16 Excavation

2 Excavating top soil for preservation, average depth 150mm. m2 272 3.00

3 Excavating pits(11 nr), maximum depth ≤ 2.00m. m3 247 8.00

4 Excavating trenches for grade beams, width ≤ 0.3m m3 15 10.00

31 23 23 .13 Backfill

5 Filling to excavations, average thickness > 0.25 m, arising from excavated m3 202 12.00

fills shall be compacted to 75% relative density for cohesionless soils as per ASTM

D4254/ASTM D4293 or 95% maximum density as determined by ASTM D698 for cohesive

material, as per the Drawings and Specifications).

31 23 23.23 Compaction

6 Surface treatments, compacting bottom of excavation, compaction to mee m2 349 3.00

relative density for cohesionless soils or 95% maximum density as determined by ASTM

ACTIVE COMPONENTS (AS PER Q&A 487) DISTRIBUTION CABINET

Page 649: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

D1557 for cohesive materialas per the Drawings and Specifications)

31 23 16.26 Rock Removal

7 Disposal of excavated material, off site as stated in the Specification. m3 61 4.00

CF

BF

31 31 16 Termite Control

1 Termite control for the horizontal surface (method and type of treatment as m2 168 1.00

Drawings and Specifications)

2 Termite control for vertical surface (method and type of treatment as per m2 424 0.00

and Specifications)

Additional Items

3 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Total for EARTHWORK

CARRIED TO SUMMARY US Dollar

03 00 00 Concrete

Page 650: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

04 00 00 Masonry

05 00 00 Metal

06 00 00 Wood, Plastics and Composites

07 00 00 Thermal and Moisture Protection

08 00 00 Openings

09 00 00 Finishes

10 00 00 Specialties

11 00 00 Equipment

12 00 00 Furnishing

22 00 00 Plumbing

23 00 00 Heating, Ventilating and Air Conditioning (HVAC)

26 00 00 Electrical

27 00 00 Communications

31 00 00 Earthwork

SUBTOTAL

54

SUBTOTAL

MULTIPLY BY 54 NR VILLAS

Page 651: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

AMOUNT FOR VILLA TYPE V3 TO SUMMARY US Dollar

Page 652: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Amount

4,428.00

26,600.00

8,288.00

348,618.00

14,775.00

3,247.00

1,128.00

6,800.00

896.00

198.00

Page 653: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

414,978.00

414,978.00

5,406.00

5,406.00

27,058.00

5,876.00

Page 654: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

32,934.00

6,364.00

5,680.00

12,848.00

Price Included

Price Included

Page 655: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

24,892.00

24,892.00

468.00

992.00

978.00

1,778.00

1,060.00

530.00

670.00

6,476.00

31,368.00

Page 656: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1,130.00

790.00

452.00

1,980.00

1,144.00

6,660.00

540.00

12,696.00

12,696.00

4,140.00

306.00

Page 657: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

4,446.00

17,142.00

7,278.00

7,624.00

7,616.00

6,660.00

Page 658: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

29,178.00

29,178.00

11,074.00

3,880.00

6,330.00

994.00

1,130.00

Page 659: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

17,650.00

16,648.00

3,108.00

60,814.00

60,814.00

724.00

Page 660: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3,884.00

264.00

164.00

274.00

3,756.00

9,066.00

9,066.00

6,710.00

0.00

Page 661: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

105,768.00

880.00

9,262.00

1,953.00

12,095.00

12,095.00

20,020.00

561.00

5,248.00

3,180.00

8,784.00

Page 662: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3,128.00

544.00

1,539.00

2,400.00

1,880.00

47,284.00

47,284.00

10,368.00

1,120.00

1,680.00

6,369.00

Page 663: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2,420.00

1,760.00

770.00

2,662.00

27,149.00

86,528.00

1,164.00

1,054.00

126.00

132.00

186.00

210.00

102.00

Page 664: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2,974.00

2,974.00

108.00

152.00

8,672.00

5,176.00

2,938.00

2,238.00

1,498.00

Page 665: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2,462.00

23,244.00

23,244.00

102.00

102.00

Page 666: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

26,320.00

AS PER Q&A-77 NOT INCLUDED

IN THE SCOPE OF WORKS

930.00

AS PER Q&A-77 NOT INCLUDED

IN THE SCOPE OF WORKS

AS PER Q&A-77 NOT INCLUDED

IN THE SCOPE OF WORKS

930.00

Page 667: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

0.00

150.00

272.00

960.00

included in sanitary fixture section 224000

included in sanitary fixture section 224000

272.00

432.00

220.00

80.00

138.00

200.00

Page 668: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

420.00

3,144.00

3,144.00

992.00

1,292.00

504.00

2,450.00

1,520.00

116.00

3,152.00

368.00

Page 669: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

384.00

184.00

158.00

11,120.00

11,120.00

Page 670: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

220.00

408.00

870.00

580.00

432.00

1,008.00

432.00

850.00

Page 671: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

4,800.00

4,800.00

270.00

544.00

252.00

1,100.00

1,200.00

644.00

1,920.00

228.00

Page 672: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1,878.00

8,036.00

8,036.00

404.00

1,026.00

86.00

1,538.00

As per the drawing it is integrated

with the Acrylic Countertop

82.00

584.00

As per Q&A-383, the sink bowl is

integrated with the Acrylic Countertop

996.00

850.00

Page 673: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

5,566.00

5,566.00

1,272.00

44.00

3,052.00

916.00

410.00

2,048.00

80.00

Page 674: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

7822

40,488.00

3,900.00

Page 675: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

5,400.00

9,300.00

9,300.00

132.00

152.00

170.00

92.00

50.00

52.00

266.00

Page 676: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1,620.00

As per Q&A-361 item is deleted

2,534.00

2,534.00

134.00

134.00

148.00

404.00

Page 677: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

100.00

100.00

110.00

150.00

278.00

278.00

340.00

128.00

128.00

304.00

152.00

88.00

528.00

3,504.00

3,504.00

Page 678: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

5,942.00

4,554.00

4,554.00

5,360.00

4,554.00

1,227.00

1,227.00

27,418.00

27,418.00

205.00

Page 679: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

205.00

42,961.00

3,581.00

1,229.00

48.00

90.00

686.00

Page 680: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

537.00

871.00

7,042.00

7,042.00

4,353.00

2,395.00

1,091.00

42.00

63.00

460.00

443.00

Page 681: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

8,847.00

8,847.00

578.00

2,304.00

3,325.00

Page 682: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

6,207.00

6,207.00

180.00

48.00

22.00

126.00

532.00

160.00

160.00

470.00

3,672.00

Page 683: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

5,370.00

5,370.00

4,160.00

2,640.00

1,800.00

1,158.00

1,134.00

660.00

736.00

612.00

8,000.00

1,332.00

5,406.00

27,638.00

27,638.00

Page 684: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2,464.00

80.00

184.00

116.00

780.00

3624

58,728.00

Page 685: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

564.00

204.00

68.00

340.00

2,262.00

AS PER Q&A # 317 NOT IN THE SCOPE

AS PER Q&A # 317 NOT IN THE SCOPE

3,400.00

6,838.00

6,838.00

418.00

916.00

218.00

1,304.00

220.00

Page 686: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2,168.00

288.00

1,088.00

124.00

194.00

136.00

480.00

7,554.00

7,554.00

136.00

6,094.00

included in the above

1,400.00

540.00

Page 687: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

5,828.00

13,998.00

28,390.00

544.00

816.00

1,976.00

150.00

2,424.00

1,047.00

Page 688: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

244.00

7,201.00

7,201.00

168.00

0.00

7,369.00

414,978.00

Page 689: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

5,406.00

32,934.00

31,368.00

17,142.00

105,768.00

86,528.00

26,320.00

930.00

0.00

40,488.00

42,961.00

58,728.00

28,390.00

7,369.00

899,310.00

###

Page 690: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

###

Page 691: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Item Nr. Description Unit Qty

03 00 00 - CONCRETE

03 11 13 Structural Cast-in-Place Concrete Forming

1 m3 13

03 31 00 Structural Concrete

2 Reinforced concrete 35Mpa for strip footing m3 39

3 Reinforce concrete 35MPa for slab on grade with 7Ø8 / Liner meter thickness 150mm m3 27

Precast Concrete

4 Precast concrete for super structure item 1

Concrete Topping

5 Sand cement concrete screed with wire mesh thick 50mm for floors above m2 349

hollow core slabs.

6 Sand cement foam concrete to slab at roof average 75mm thick m2 149

7 Sealed Concrete for beds at roof thick 350mm m2 1

8 Sand cement screed for floors to receive finishing thickness 50mm m2 200

03 30 53 - Miscellaneous Cast-in-situ Concrete

9 300mm wide x 200mm high reinforced concrete 35 Mpa for lintel m 19

10 300mm wide x 400mm thick reinforced concrete 35 Mpa for lintel m 11

11 100mm wide x 200mm thick reinforced concrete 35 Mpa for lintel m 12

Plain concrete 20MPa for blinding thickness 100mm for footing and 50mm under slab on grade

Page 692: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for CONCRETE

CARRIED TO SUMMARY

04 00 00 - Masonry

04 22 00 - Concrete Unit Masonry

Internal walls and Partitions

1 100mm thick CMU wall non fire rated m2 115

Total for MASONRY

CARRIED TO SUMMARY

05 00 00 METALS

All metalworks herein shall be completed full incompliance with the Drawings V4-A902

and Specification.

05 12 00 Structural Steel Framing

1 Supply and fix 200mm x 50mm rectangular hollow aluminium powder coated pergola, m2 12

wall mounted, kind, quality, fittings, fixtures, accessories as per Drawings and as per

Specifications.

05 70 00 Decorative Metal

2 Supply and fix 50mm x 50mm galvanized steel powder coated hand rails for staircase side m 7

mounted to stair slab, kind, quality, fittings, fixtures, accessories as shown on Drawings

and as per Specification.

3 Supply and fix 50mm x 50mm galvanized steel powder coated hand rails for balcony, m 19

floor mounted, kind, quality, fittings, fixtures, accessories as shown on Drawings and as

per Specification.

As per Question and Answer No (144) balcony handrail changed to aluminum powder coated handrail

Page 693: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

05 00 00 Metals

Additional Items

4 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Total for METALS

CARRIED TO SUMMARY

06 00 00 WOOD, PLASTICS, AND COMPOSITES

06 41 00 Architectural Wood Casework

As per Question and Answer No. (89) the kitchen cabinet changed to Aluminum

1 Supply and fix kitchen under counter & overhead cabinets (4600mm + 650mm) long nr 1

600mm wide (counter tops measured separately) at kitchen with wall cabinet MDF

melamine laminated with aluminum edge, base & overhead cabinets with polished

chrome cabinet pull handles and all other accessories as per the Drawing nr V4-A905 and

Specification.

2 Supply and fix kitchen under counter & overhead cabinets 550mm long 600mm wide nr 1

(counter tops measured separately) at kitchen with wall cabinet MDF melamine

laminated with aluminum edge, base & overhead cabinets with polished chrome cabinet

pull handles and all other accessories as per the Drawing nr V4-A905 and Specification.

3 Supply and fix kitchen under counter & overhead cabinets 2000mm long 600mm wide nr 1

(counter tops measured separately) at kitchen with wall cabinet MDF melamine

laminated with aluminum edge, base cabinets with polished chrome cabinet pull

handlesand all other accessories as per the Drawing nr V4-A905 and Specification.

4 Supply and fix kitchen under counter & overhead cabinets 800mm long 600mm wide nr 1

(counter tops measured separately) at kitchen with wall cabinet MDF melamine

laminated with aluminum edge, base cabinets with polished chrome cabinet pull

Page 694: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

handlesand all other accessories as per the Drawing nr V4-A905 and Specification.

06 61 16 Solid Surfacing Fabrications

5 Supply and fix solid acrylic counter top shaped 1350 long 600mm wide with opening for nr 2

wash basin as shown in the Drawing nr V4-A903 and Specification.

6 Supply and fix solid acrylic counter top shaped 1200mm long 600mm wide with opening nr 1

for wash basin as shown in the Drawing nr V4-A903 and Specification.

7 Supply and fix solid acrylic counter top shaped 1700mm long 600mm wide with opening nr 1

for wash basin as shown in the Drawing nr V4-A903 and Specification.

Wood, Plastics, and Composites (Cont'd)

1 Supply and fix Solid Acrylic counter top shaped (4600mm+650mm) long 600mm wide nr 1

with opening for double bowl kitchen sink including, waste disposal unit, 100mm up

stand for counter top as shown in the Drawing nr V4-A903, V4-EP201 and Specification.

2 Supply and fix solid acrylic counter top 550mm long 600mm wide including 100mm nr 1

upstand for counter top as shown in the Drawing nr V4-A903 and Specification.

3 Supply and fix solid acrylic counter top 2000mm long 600mm wide including 100mm up nr 1

stand for counter top as shown in the Drawing nr V4-A903 and Specification.

4 Supply and fix solid acrylic counter top 1600mm long 600mm wide including 100mm up nr 1

stand for counter top as shown in the Drawing nr V4-A903 and Specification.

06 00 00 Wood, Plastics, and Composites

Additional Items

5 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Total

Page 695: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for WOOD, PLASTICS, AND COMPOSITES

CARRIED TO SUMMARY

07 00 00 THERMAL AND MOISTURE PROTECTION

07 10 00 Damp proofing and Waterproofing

Substructure Waterproofing

All works herein shall be completed in full incompliance with the Drawings nr V-S002, VS003,

V-S004, V-S005, V-S401 and Specification.

1 Two coats of bitumen paint for sub structure for vertical surface. m2 77

2 Ditto for horizontal surface m2 72

3 Waterproofing works for substructure with vapour barrier 250 microns, horizontal m2 168

surface as per the Drawings and Specification

Wet Area Waterproofing / Roof Waterproofing

All works herein shall be completed in full incompliance with the Drawings nr V4-A202,V4-

A203, V4-A204, V4-A205,V4-A903, V4-A907 and Specification.

4 Waterproofing works for wet area, vertical surface, as per the Drawings and Specification, m2 68

5 Waterproofing works for wet area, horizontal surface, as per the Drawings and Specification m2 41

Roof Waterproofing

6 Waterproofing membrane for roof and second floor terrace, horizontal surface, m2 152

as per the Drawings and Specification.

7 Geotextile layer for roof and second floor terrace water proofing works, horizontal m2 152

surface, as per the Drawings and Specification.

Page 696: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

THERMAL AND MOISTURE PROTECTION (Cont'd)

1 100mm thick insulation for water proofing works at roof and second floor terrace water m2 152

proofing works, horizontal surface, as per the Drawings and Specification.

07 21 13 Board Insulation

2 Anti-vibration insulation, thickness as per the manufacturers requirements at water tank m2 9

bearing at room as per the Drawing nr V-S401 and Specification.

Total for THERMAL AND MOISTURE PROTECTION

CARRIED TO SUMMARY

08 00 00 OPENINGS

All works herein shall be completed in full compliance with the Doors & Windows Note

Schedule Drawings V4-A801, V4-A802, V4-A803 and Specification.

Note: Notwithstanding the Provisions of the Standartd Method of Measurement, door

sets including doors, frames, vision panels, decoration and ironmongery have been

measured as a composite item and the Contractor should make due reference to the

drawings and specification. No claim for lack or want of knowledge will be entertained

08 11 00 Metal Doors and Frames

As per Question and Answer No (420)

1 Supply and steel flush door with fixed double glazed panel, 54mm thick, 1600mm wide x nr 1

2700mm high with 6mm low glass +16+6mm clear glass vision panel including frame,

type D1, finished with and including paint, all accessories and hardware including but not

limited to hinges HDH type, outside and inside door lock, lever handles and latch, wall

stop with roses and escutcheons as stated in the Specification.

08 14 00 - Wood Doors

2 Supply and fix wooden flush door, 44mm thick, 900mm wide x 2200mm high including nr 4

frame, type D2, finished with and including paint, all accessories and hardware including

Page 697: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

but not limited to hinges BBS type, inside door lock, lever handles and latch, wall stop

with roses and escutcheons as stated in the Specification.

3 Supply and fix wooden flush door, 44mm thick, 800mm wide x 2200mm high including nr 5

frame, type D3, finished with and including paint, all accessories and hardware including

but not limited to hinges BBS type, inside door lock, lever handles and latch, wall stop

with roses and escutcheons as stated in the Specification.

08 51 13 Aluminum Windows

4 Supply and fix aluminium double glazed window, 3000mm wide x 2200mm high, nr 1

glass panel with open glass door window including frame, type W1, finished, all

accessories and hardware including but not limited to hinges, handle, lock, weather tight

strip etc. as stated in the Drawings and Specification.

OPENINGS(Cont'd)

1 Supply and fix aluminium double glazed window, 3000mm wide x 2700mm high, nr 4

aluminium sliding shutters 1450mm x 2700mm, in front sliding glass panel including

frame, type W2, finished , all accessories and hardware including but not limited to

hinges, handle, lock, weather tight strip etc. as stated in the Drawings and Specification.

2 Supply and fix aluminium double glazed window, 2000mm wide x 2700mm high, nr 3

aluminium sliding shutters 950mm x 2700mm, in front sliding glass panel including

frame, type W3, finished, all accessories and hardware including but not limited to

hinges, handle, lock, weather tight strip etc. as stated in the Drawings and Specification.

3 Supply and fix aluminium double glazed window, 500mm wide x 1100mm high including nr 2

frame, type W4, finished, all accessories and hardware including but not limited to

hinges, handle, lock, weather tight strip etc. as stated in the Drawings and Specification.

08 62 00 Unit Skylights

4 Supply and fix skylight 600mm x 600mm ( size, kind, quality, surface treatment, method nr 3

of jointing/sealing, fixings finishing etc. as per the Drawings nr V4-903, V4-A907 and

Specification).

08 83 00 Mirrors

Page 698: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

5 Supply and fix fixed mirror 1350mm width x 1100mm high for bathrooms ( size, kind, nr 2

quality, surface treatment, method of jointing, etc. as per the Drawings nr V4-903 and

Specification).

6 Supply and fix fixed mirror 1200mm width x 1100mm high for bathrooms ( size, kind, nr 1

quality, surface treatment, method of jointing, etc. as per the Drawings nr V4-903 and

Specification).

7 Supply and fix fixed mirror 1700m width x 1100mm high for bathrooms ( size, kind, nr 1

quality, surface treatment, method of jointing, etc. as per the Drawings nr V4-903 and

Specification).

OPENINGS(Cont'd)

08 91 00 Louvers

1 Supply and fix louvers for water tanks at roof, 1600mm high kind, quality, fittings, fixings, m2 17

accessories, finishing etc. as shown on Drawing nr 501 and 902 and as per Specification.

08 00 00 Openings

Additional Items

2 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

As per Question and Answer No. (431)

2.1 Fixed louver window (W5) 350 x 300 mm as per dwg. (V4-A802) nr 2

2.2 lm 5

2.3 M²

As per Question and Answer No. (544) toughened laminated glass balustrade behind shutter where applicable

As per Question and Answer No. (531) Electrically Operated Sliding Shutter System (OPTIONAL)

Page 699: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for OPENINGS

CARRIED TO SUMMARY

09 00 00 - FINISHES

09 23 00 Gypsum Board wall

1 Gypsum wall above wooden cabinet closet m2 8

09 24 00 Cement Plastering

2 15mm thick internal plastering for block walls to receive paint m2 100

3 Ditto - for walls to receive tiling at wet areas, m2 119

FINISHES (Cont'd)

09 30 13 Ceramic Tiling

Floor Tiling

1 Porcelain tile flooring (type - FT1), size 600mm x 600mm, m2 195

2 Concrete pavers (FT9) at ground floor parking area, size 600mm x 600mm m2 72

3 Concrete pavers (FT9) at first floor terrrace, size 600mm x 600mm m2 42

4 Terrazo tiles, size 400x400mm at roof and water tank area m2 109

As per client Question and Answer No. 63, the balcony floor finish is changed to porcelain tiles FT5

Page 700: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Wall tiling

5 Mosaic tile (type WT4) 100mm x 300mm size for kitchen walls, m2 28

6 White body wall tile (type WT1) 325mm x 977mm size for toilets and bathroom walls, m2 108

Skirting

As per client Question and Answer No 293, the height for skirting 100mm

1 MDF skirting 100mm height, m 90

2 Porcelain tile skirting 100mm height (type - FT1) m 10

3 Porcelain tile skirting 100mm high typw FT1 forkitchen laundry m 22

As per Q&A No. 63 the skirting for stair case changed to porcelain

4 MDF Skirting 100mm high for stair case m 16

Stair Finish

5 Porcelain tile tread (type - FT1), 280mm wide x 1100mm length, m 21

6 Porcelain tile for riser (type - FT1), 160mm high x 1100mm length, m 24

FINISHES (Cont'd)

09 50 00 Ceilings

1 Supply and install gypsum ceiling, depth of suspension 500 - 1000 mm m2 197

as per the Drawings No V3-A905,V3-A901

As per client Question and Answer No 76, the skirting for balcony changed to porcelain

Page 701: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2 m2 11

3 m2 24

09 91 00 - Painting

Wall -Painting

3 Painting for internal walls, m2 270

4 Painting for walls in staircases, m2 75

Ceiling -Painting

5 Painting for staircase ceiling, m2 21

6 Painting for gypsum board ceiling m2 332

Total for FINISHES

Supply and install gypsum ceiling for kitchen area depth of suspension 500-1000mm as per drawimng nr. V4-A905 and V4-A901

Supply and install gypsum ceiling for toilets, laundry and baathroom depth of suspension 500-1000mm as per drawimng nr. V4-A905 and V4-A901

Page 702: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CARRIED TO SUMMARY

10 00 00 SPECIALTIES

10 28 00 –Toilet, Bath and Laundry Accessories

Supply & install Plumbing Fixtures as shown in Drawing nr V4-A903 and Technical

Specification including all accessories, fittings , flexible connections etc.

1 Paper towel dispenser (PTD) nr 4

2 Soap dispenser (SD) nr 4

3 Towel ring nr 4

4 Robe hook nr 4

5 Towel bar nr 4

10 44 13.13 Portable Fire Extinguishers

All items hereunder to be described with kind, quality, size, method of fixing , etc. as per

the Drawings and Specification).

6 Supply & install Portable Fire Extinguishers nr 1

7 Supply & install fire blanket nr 1

10 57 00 Wardrobe and Closet Specialties

8 Supply and fix wardrobe 2150 mm length, 600mm wide, 2400mm high, with MDF nr 2

laminated dark wood veneer shelves, door with MDF white matt lacquer finish and

chromed stainless steel handles, and all other accessories as per the Drawing nr V4-A905

and Specification.

9 Supply and fix wardrobe 2300 mm length, 600mm wide, 2400mm high, with MDF nr 1

laminated dark wood veneer shelves, door with MDF white matt lacquer finish and

chromed stainless steel handles, and all other accessories as per the Drawing nr V4-A905

and Specification.

SPECIALTIES (Cont'd)

Page 703: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1 Supply and fix wardrobe 2600 mm length, 600mm wide, 2400mm high, with MDF nr 1

laminated dark wood veneer shelves, door with MDF white matt lacquer finish and

chromed stainless steel handles, and all other accessories as per the Drawing nr V4-A905

and Specification.

2 Supply and fix 750mm wide, 2000mm high, 800mm depth , MDF laminated shelves at nr 1

bathroom FF05, 2400mm high, with MDF laminated dark wood veneer shelves, door with

MDF white matt lacquer finish and chromed stainless steel handles, and all other

accessories as per the Drawing nr V4-A903 and Specification.

10 22 23 Portable Partitions, Screens, and Panels

3 Supply and fix 8mm thick tempered glass 1120mm x 2400mm high partition with 700mm nr 1

x 2200mm door, finished, all accessories and hardware including but not limited to

hinges, handle, etc. as stated in the Drawing nr V4-A903 and Specification.

4 Supply and fix 8mm thick tempered glass 800mmx 2400mm high partition with 700mm x nr 1

2200mm door, finished, all accessories and hardware including but not limited to hinges,

handle, etc. as stated in the Drawing nr V4-A903 and Specification.

5 Supply and fix 8mm thick tempered glass 950mmx 2400mm high partition with 700mm x nr 1

2200mm door, finished, all accessories and hardware including but not limited to hinges,

handle, etc. as stated in the Drawing nr V4-A903 and Specification.

10 00 00 Specialties

Additional Items

6 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

6.01 Towel Pin nr 3

Total for SPECIALTIES

CARRIED TO SUMMARY

11 00 00 EQUIPMENT

All items hereunder to be described with information such as appropriate to the

procurement , design, supply, execution, type, kind, quality, size, method of fixing ,

specified codes of practice, etc. as per the Drawings and Specification).

Page 704: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

11 30 00 Residential Equipment

AS PER Q&A-77 NOT INCLUDED

1 Refrigerator/freezer nr 1

2 Exhaust hoods nr 1

AS PER Q&A-77 NOT INCLUDED

3 Cooker nr 1

AS PER Q&A-77 NOT INCLUDED

4 Washing Machine nr 1

11 00 00 Equipment

Additional Items

5 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Total for EQUIPMENT

CARRIED TO SUMMARY

12 00 00 FURNISHING

All items hereunder to be described with information such as appropriate to the

procurement , design, supply, execution, type, kind, quality, size, method of fixing ,

specified codes of practice, etc. as per the Drawings and Specification).

12 00 00 Furnishing

Additional Items

1 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Total for FURNISHING

CARRIED TO SUMMARY

Page 705: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

22 00 00 - PLUMBING

All items described hereunder to be of specified code of practice and regulations, kind,

quality, size, method of fixing , finishes or surface treatments, etc. as per the Drawings

and Specification

22 05 23 General-Duty Valves for Plumbing Piping

Valves

Valves are classified according to type . Material and/or size . Rates include furnishing

and installing of valves, testing at manufacturer's premises and on site; diameters of

valves and water meter according to pipe diameter which will be connected with it; as

per Drawings and Specfication.

Gate Valve

1 25 mm diam. nr 2

2 32 mm diam. nr 2

3 40 mm diam. nr 1

4 50 mm diam. nr 10

Angle Valve

5 20 mm diam. nr 24

6 25 mm diam. nr 4

Globe Valve

7 25 mm diam. nr 1

8 32 mm diam. nr 2

9 40 mm diam. nr 1

Non-Return Valve

10 20 mm diam. nr 2

11 25 mm diam. nr 5

12 50 mm diam. nr 2

Pressure Reducing Valve

Page 706: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

13 50 mm diam. nr 1

22 11 16 Domestic Water Piping

Domestic water piping is classified by material and diameter. Rates include furnishing

and installing of pipes, fittings, accessories, fixing supports, joints, sleeves, special parts,

connections, hanger supports. Rates to include all works and materials necessary for

complete installation for piping system as per the Drawings and Specification.

PLUMBING (Cont'd)

Water Supply System

1-Cold Water Supply

1 50 mm diameter. m 20

2 40 mm diameter. m 9

3 32 mm diameter. m 14

4 25 mm diameter. m 25

5 20 mm diameter. m 36

2-Hot Water Supply

6 20 mm diameter. m 55

3 - Accessories

7 Hose Bibb 20mm . nr 2

8 Water Meter 50 mm. nr 1

9 Water Hammer Arrestor nr 3

10 Automatic Air Vent. nr 3

Page 707: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

11 Pressure Gauge . nr 2

12 Strainer 50 mm. nr 1

22 13 16 Sanitary Waste and Vent Piping

Sanitary Pipe Works

Sanitary pipe works is classified by material and diameter. Rates include furnishing and

installing of pipes, fittings, accessories, fixing supprt, joints, sleeves , special parts,

connections, hanger supports. Rates for pipework below ground also include excavation,

backfilling , civil work, trenches and any other accessories or fittings necessary for

complete installation of the piping system.Testing of pipes at the manufacturer's

premises is included.All as per the Drawings and Specfication.

Pipes and fitting above ground

Waste Pipe

13 50 mm diameter. m 12

14 75 mm diameter. m 10

15 110 mm diameter. m 22

Soil Pipe

16 110 mm diameter. m 17

PLUMBING (Cont'd)

Pipes and fitting below ground

Waste pipe

1 75 mm diameter. m 4

Page 708: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2 110 mm diameter. m 12

Soil Pipe

3 110 mm diameter. m 10

Vent Pipe Works

Vent pipes are classified by material and diameter. Rates include furnishing and installing

of pipes, fittings, accessories, fixing supprt, joints, sleeves, special parts, connections,

hanger supports. Rates include furnishing and installing of pipes, fittings, accessories,

fixing supprt, joints, sleeves , special parts, connections, hanger supports. Rates for

pipework below ground also include excavation, backfilling , civil work, trenches and any

other accessories or fittings necessary for complete installation of the piping

system.Testing of pipes at the manufacturer's premises is included.All as per the

Drawings and Specfication.

Pipes and fittings above ground

4 75 mm diameter. m 35

Pipes and fitting below ground

5 75 mm diameter. m 5

22 13 19.13 Sanitary Drains

Sanitary drains (to include rainwater pipework and condensate drain pipework) are

classified by material and diameter. Rates include furnishing and installing of pipes,

fittings, accessories, fixing supports, joints, sleeves, special parts, connections, hanger

supports. Rates also include testing of pipes at the manufacturer's premises. All as per

the Drawings and specfication.

Rain water Pipe

6 75 mm diameter. m 14

Condensate Drain Pipe Works

7 20 mm diameter. m 22

8 25 mm diameter. m 8

PLUMBING (Cont'd)

Page 709: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

22 33 00 Electric Domestic Water Heaters

Electric domestic water heaters are classified according to capacity. Rates include

furnishing of heater complete with safety valves, air vent, pressure and tempearture

relief gauges, drain valves, all valves set (angle, gate, non return, etc .), thermostat,

heating element, contactors, switch, support, bolts, nuts, connection of pipes, testing on

site, commissioning and putting into service.

1 EWH-V4-01 with (30 liters / 1200 W) capacity. nr 2

2 EWH-V4-02 with (80 liters / 1200 W) capacity. nr 2

3 EWH-V4-03 with (100 liters / 1500 W) capacity. nr 2

22 40 00 Plumbing Fixtures

All items described hereunder to be of kind, quality, size, nature of base, method of

fixing, complete with accessories etc. as per the Drawings nr V1-903 and Specification

4 Floor Drain (FD) nr 6

5 Flexible Shower Hose nr 4

6 Water Closet nr 4

7 Floor clean out nr 2

8 Roof drain nr 4

9 Vent cap nr 1

10 Bath tub (BT) including taps, plug, accessories and fitting. nr 1

As per the drawing it is integrated

11 Wash basin (WB) nr 4

As per Q&A no. 358 colthes washing not in contract, only connections

12 Washing machine connections (washing machine not in contract) nr 1

As per Q&A no. 360 shower channel to be used

13 Shower (SHO) including shower channel, mixer tap, fitting, spray and adjustable bar nr 2

As per Q&A-383, the sink bowl is

14 Kitchen sink nr 1

Page 710: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

PLUMBING (Cont'd)

1 Taps for wash basin including fittings , plugs, valves, connections and waste. nr 4

2 Mixer tap for kitchen sink including fitting, plugs, chrome plated pipes, valves and nr 1

waste

22 00 00 - Plumbing

Additional Items

3 Inspection chamber as per Drawings and Specification; connected directly to nr 1

sewer network.

4 Clean out (CO) nr 5

5 Roof Water tank as per Specification; rate shall be include supplying and installing, nr 1

all fittings, accessories, valves, pipework, vents etc. as per the Drawings and

Specification

6 Gully Trap nr 1

Additional Items

7 Marking the position of holes, mortices and chases in the structure Item 1

8 Identification; plates, discs, labels, tapes, bands, arrows, symbols, letters, numbers and Item 1

charts; as stated on drawings and in Specification

9 Testing and commissioning of entire installation Item 1

10 Preparation of as-built drawings Item 1

11 Preparation of operation and maintenance manuals Item 1

12 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Page 711: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for PLUMBING

CARRIED TO SUMMARY

23 00 00 - HEATING, VENTILATING, AND AIR CONDITIONING (HVAC)

All HVAC works shall be completed as per the Drawings and Specification.

23 23 00 Refrigerant Piping

Supply and fix refrigerant pipes for FCU from condensing units to indoor installed AC

units including fittings, sleeves and all accessories as per the Drawings and Specification

1 20 mm diameter with max liquid line 10 mm. m 65

23 31 00 HVAC Ducts and Casings

All items described hereunder to be of type, kind, quality, size, method of fixing, specified

codes of practice, method of fixing/supports, etc. as per the Drawings and Specification

Notwithstanding the provisions of the Standard Method of Measurement, internal Note

ductwork is to include insulation to the ductwork. No claim for additional cost due to lack

or want of knowledge will be entertained

2 Supply and fix insulated indoor galvanized steel sheet metal duct work for all HVAC work Kg 517

as specified and as indicating on drawings, complete with bends, supports, connections,

fittings, splices and all accessories to complete the work.

Page 712: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

23 33 13.13 Volume-Control Dampers

All items described hereunder to be of type, kind, quality, size, method of fixing, specified

codes of practice, etc. as per the Drawings and Specification

Volume Dampers

3 Volume Damper ; 200 mm dia. circular damper. nr 1

4 Volume Damper ; 300 mm dia. circular damper. nr 3

5 Volume Damper ; 350 mm dia. circular damper. nr 1

HEATING, VENTILATING, AND AIR CONDITIONING (Cont'd)

23 33 46 Flexible Ducts

All items described hereunder to be of type, kind, quality, size, method of fixing, specified

codes of practice, etc. as per the Drawings and Specification

1 Supply and install Flexible duct with insulation ; size 200 mm dia. m 1

2 Supply and install Flexible duct with insulation ; size 300 mm dia. m 2

3 Supply and install Flexible duct with insulation ; size 350 mm dia. m 1

23 34 00 HVAC Fans

All items described hereunder to be of capacity, design, supply, execution, type, kind,

quality, size, method of fixing , specified codes of practice, etc. as per the Drawings and

Specification

Supply and install exhaust fan as specified and as indicated in drawing. Fan consists of

casing, fan, motor, control, filter, sand trap louver, all electrical works (compenents,

wiring, switches etc.) and all accessories. Electrical power supply 220/1/60.

Wall Mounted

4 Exhaust Fan (EF-01) ;40 Pa with total air flow 50 L/S . nr 1

Ceiling Mounted

5 Exhaust Fan (EF-02 to EF-06) ;100 Pa with total air flow 25 L/S . nr 5

Page 713: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Range Hood Fan

6 Range Hood Fan (RH-01) ;150 Pa with total air flow 50 L/S . nr 1

23 37 00 Air outlets and Inlets

All items described hereunder to be of type, kind, quality, size, method of fixing, specified

codes of practice, etc. as per the Drawings and Specification

Supply and install Painted Supply linear bar air Register with complete accessories.as per

the Drawings and Specification.

7 Size 700x150 mm ; 215 L/s. nr 1

8 Size 800x150 mm ; 300 L /s. nr 1

9 Size 900x150 mm ; 320 L/s. nr 1

10 Size 900x150 mm ; 335 L/s. nr 1

HEATING, VENTILATING, AND AIR CONDITIONING (Cont'd)

1 Size 1000x150 mm ; 270 L/s. nr 1

Supply and install Painted Return linear bar air grille with complete accessories.as per the

Drawings and Specification.

2 Size 700x150 mm ; 215 L/s. nr 1

Page 714: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3 Size 800x150 mm ; 300 L /s. nr 1

4 Size 900x150 mm ; 320 L/s. nr 1

5 Size 900x150 mm ; 335 L/s. nr 1

6 Size 1000x150 mm ; 270 L/s. nr 1

Supply and install 3 way Supply ceiling diffuser with complete accessories.as per the

Drawings and Specification.

7 Size 375X375 mm ; 100 L/s. nr 1

8 Size 450X450 mm ; 175 L/s. nr 3

9 Size 450X450 mm ; 250 L/s. nr 1

Supply and install 4 way Return ceiling diffuser with complete accessories.as per the

Drawings and Specification.

10 Size 450X450 mm ; 175 L/s. nr 3

11 Size 450X450 mm ; 250 L/s. nr 1

Exhaust air louver

12 Exhaust air louver (200X150)mm. nr 3

13 Exhaust air louver (250X150)mm. nr 3

23 82 00 Convection Heating and Cooling Units

All items described hereunder to be of capacity, design, supply, execution, type, kind,

quality, size, method of fixing , specified codes of practice, etc. as per the Drawings and

Specification

Supply and install concealed fan coil unit as specified and as indicated in drawing. Unit to

be complete with air cooled condensing unit, fan, filter, valves, controls, thermostat, all

electrical works (compenents, wiring, switches etc.) and all accessories. Electrical power

supply 220/1/60.

14 (FCU-01) , 620 L / s , 50 Pa ; Electrical data power 5 KW . nr 1

15 (FCU-02) , 525 L / s , 50 Pa ; Electrical data power 5 KW . nr 1

16 (FCU-03) , 320 L / s , 50 Pa ; Electrical data power 4 KW . nr 1

17 (FCU-04) , 300 L / s , 50 Pa ; Electrical data power 4 KW . nr 1

Page 715: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

18 (FCU-05) , 335 L / s , 50 Pa ; Electrical data power 4 KW . nr 1

19 (FCU-06) , 215 L / s , 50 Pa ; Electrical data power 3 KW . nr 1

HEATING, VENTILATING, AND AIR CONDITIONING (Cont'd)

23 05 93 Testing, Adjusting and Balancing for HVAC

All items hereunder to be described with type of installation, preparatory operations,

stages of test (nr), required attendance, applicable codes etc. as per the Drawings and

Specification).

1 Air balancing of the ducting network Item 1

2 Testing, balancing and commissioning of all the equipment Item 1

Additional Items

3 Marking the position of holes, mortices and chases in the structure Item 1

4 Identification; plates, discs, labels, tapes, bands, arrows, symbols, letters, numbers and Item 1

charts; as stated on drawings and in Specification

5 Testing and commissioning of entire installation Item 1

6 Preparation of as-built drawings Item 1

7 Preparation of operation and maintenance manuals Item 1

8 The Contractor is to list here and price any items shown on the Drawings, mentioned in Item

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Page 716: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for HVAC

CARRIED TO SUMMARY

26 00 00 - ELECTRICAL

All works hereunder shall be completed as per the Drawings and Specification.

26 05 19 Low Voltage Electrical Power Conductors and cables

All items hereunder to be of type, kind, number of cores, armoring and sheathings,

method of fixing , specified codes of practice, etc. as per the Drawings and Specification).

Notwithstanding the Provisions of the method of measurement, cables have been

itemised and referenced to the circuit. The contractor is to make due reference to

drawings nrs E000, E001, E002, E003, EL201, EL202, EP201, EP202, LP201, LP202, LP203,

PS301, PS302 MD401, MD402 and MD403 for full details and is to allow for all cabling,

junctions, flexible connections, feeder units etc. required to complete the installation in

accordance with the drawings and Specification. No claim for want or lack of knowledge

will be entertained

1 Lighting circuits Item 1

2 Power circuits Item 1

3 Fire alarm circuits Item 1

4 Cooker circuits Item 1

5 Water heater circuits Item 1

6 Fan circuits Item 1

7 Outdoor lighting circuits Item 1

8 HVAC control circuits Item 1

ELECTRICAL (Cont'd)

Page 717: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

26 05 26 Grounding and Bonding for Electrical Systems

All items hereunder to be described with information such as type, kind, number of

cores, armoring and sheathings, method of fixing , specified codes of practice, etc. as per

the Drawings and Specification).

1 Grounding system Item 1

26 05 33.13 Conduit for Electrical Systems

All items hereunder to be described with information such as type, kind, , method of

fixing , specified codes of practice, etc. as per the Drawings and Specification).

Notwithstanding the Provisions of the method of measurement, conduits have been

itemised and referenced to the circuit. The contractor is to make due reference to

drawings nrs E000, E001, E002, E003, EL201, EL202, EP201, EP202, LP201, LP202, LP203,

PS301, PS302 MD401, MD402 and MD403 for full details and is to allow for all tracking,

fixings, type, size, materials, boxes, connections etc. required to complete the installation

in accordance with the drawings and Specification. No claim for want or lack of

knowledge will be entertained

2 Lighting circuits Item 1

3 Power circuits Item 1

4 Fire alarm circuits Item 1

5 Cooker circuits Item 1

6 Water heater circuits Item 1

7 Fan circuits Item 1

8 Outdoor lighting circuits Item 1

9 HVAC control circuits Item 1

ELECTRICAL (Cont'd)

26 24 13 Switchboards

Page 718: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1 All items hereunder to be described with information such as type, kind, rated capacity,

method of fixing, cores reference to Specification, fuses, backgroung,specified codes of

practice, etc. as per the Drawings and Specification).

26 24 16 Panel boards

All items hereunder to be described with information such as type, kind, rated capacity,

method of fixing, cores reference to Specification, fuses, backgroung,specified codes of

practice, etc. as per the Drawings and Specification).

2 Distribution and panel boards Item 1

26 27 13 Electricity Metering

3 All items hereunder to be described with information such as type, kind, rated capacity, Item 1

method of fixing, cores reference to Specification, fuses, backgroung,specified codes of

practice, etc. as per the Drawings and Specification).

26 27 26 Wiring Devices

Notwithstanding the Provisions of the Method of Measurement, wiring devices shall Note

include final circuits. No claim for lack or want of knowledge shall be entertained

Switches & Push Buttons

All items hereunder to be described with information such as appropriate to the

procurement , type, kind, quality, size, method of fixing , specified codes of practice, etc.

as per the Drawings and Specification).

4 One way one gang switch nr 11

ELECTRICAL (Cont'd)

1 One way two gang switch nr 5

2 One way three gang switch nr 1

3 Two way one gang switch nr 5

Power Outlets

4 Single receptacle outlet 15A, 220V, 3 wire nr 10

Page 719: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

5 Duplex Recepacle outlet 15A, 220V, 2 pole, 3 wire nr 17

6 Double outlet; 15A 220V; 2 pole, 3 wire; floor mounted nr 3

7 1 way 20A 2P 230v switch with pilot light nr 6

8 Fusible disconnect switch, double poles, 20A, 230V, with lamp Indicator nr 3

9 Non-fusable disconnect switch, 1 phase nr 6

26 50 00 Lighting

Notwithstanding the Provisions of the Method of Measurement, lighting shall include Note

final circuits. No claim for lack or want of knowledge shall be entertained

All items hereunder to be described with information such as appropriate to the

procurement , type, kind, quality, size, method of fixing , specified codes of practice, etc.

as per the Drawings and Specification).

10 Luminaries, downlight, multi-mounting, 1 x 26W CFL; type D1 nr 11

ELECTRICAL (Cont'd)

1 Luminaries, downlight, multi-mounting, 2 x 26W CFL; type D2 nr 15

2 Luminaries, downlight, recessed-mounting, 2 x 26W CFL; compact lamp 220V, 60hz; type nr 13

D3

3 Luminaires, downlight recessed- mounting; 2 x 42W CFL; type D4 nr 4

4 Luminaire, downlight square shaped, 1 nx 50W, 220V, 60hz; type S2 nr 4

5 Luminaire, ceiling mounted, round shaped; 1 x 18W, 220V, 60hz; type R2 nr 2

6 Luminaire, wall mounted, satin steel/nickle/plastic, white; 1 x 13W, 12V; type A1 nr 3

7 Luminaire, wall mounted, satin steel/nickle/plastic, white; 1 x 18W, CPL; type W2 nr 4

8 Luminaire, wall mounted, satin steel/nickle/plastic, white; 1 x 2W, CPL; type W3 nr 8

9 Luminaire, wall mounted; 1 x 26W CPL, outdoor; type W7 nr 5

Page 720: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

ELECTRICAL (Cont'd)

26 00 00 - Electrical

Additional Items

1 Marking the position of holes, mortices and chases in the structure Item 1

2 Identification; plates, discs, labels, tapes, bands, arrows, symbols, letters, numbers and Item 1

charts; as stated on drawings and in Specification

3 Testing and commissioning of entire installation Item 1

4 Preparation of as-built drawings Item 1

5 Preparation of operation and maintenance manuals Item 1

6 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

6.01 Shaver Outlet nr 3

6.02 m 17

Total for ELECTRICAL

CARRIED TO SUMMARY

27 00 00 COMMUNICATIONS

STRUCTURED CABLING SYSTEM

4C 50mm² CU/XLPE/PVC+25mm² CU/PVC E (Cable from kWH meter to DB) (As per Q&A # 537)

Page 721: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Supply, Install, Test, connect and commission inclusive of all cabling, conduits and

containment, socket outlets, all in accordance with the relevant service provider

regulations , rules, recommendation and requirements and in accordance with the

specifications and drawings.

1 Information Outlet, Flush Type 1 DATA, 1 Telephone 0.3 Meters A.F.F.L. nr 6

2 Telephone Outlet, Wall Mounted Flush Type, MTD 0.30m A.F.F.L nr 4

3 Telephone Outlet, Wall Mounted, Flush Type 1.2 Meters A.F.F.L. nr 1

4 TV outlet, wall mounted nr 6

5 9U Telecom Cabinet, Wall Mounted nr 1

6 Set Top Box nr 6

7 LED TV nr 6

8 CAT 6A, UTP Cable m 160

9 Single Mode Fiber Optic Cable - 1 x 2 Core m See Master plan BOQ

Video Entry System / Intercom

Supply, Install, Test, connect and commission inclusive of all cabling, conduits and

containment, socket outlets, all in accordance with the relevant service provider

regulations , rules, recommendation and requirements and in accordance with the

specifications and drawings.

10 Entrance Video Door Station nr 1

11 Residential Main Station nr 1

Video Entry System / Intercom(cont'd)

1 Door release 12V nr 1

2 Wireless Handset nr 1

3 CAT 6A, UTP Cable m 20

Page 722: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Consumption Metering

Supply, Install, Test, connect and commission inclusive of all cabling, conduits and

containment, socket outlets, all in accordance with the relevant service provider

regulations , rules, recommendation and requirements and in accordance with the

specifications and drawings.

4 Metering Receiver nr 1

5 M-bus Cable, 2 x 18AWG m 22

Fire Alarm System

Supply, install, connection, testing and commisioning of wiring and equipment for Fire

Alarm System including all necessary materials and accessories to reflect complete

system installation.

6 Addressable, smoke detector nr 7

7 Addressable, heat detector nr 1

8 Multisensor Detector nr 1

9 Addressable, Manual Pull Station nr 1

10 Sounder / Fire Alarm Bell / Horn nr 2

11 Control Module nr 1

12 Fire Alarm Control Panel nr 1

13 Power Supply Unit, 24v nr 1

Fire Alarm System (cont'd)

1 Loop Cable, 2x1.5mm2 Fire Resistant m 60

2 24V Cable, 2x2.5mm2 Fire Resistant m 10

Additional Items

3 Marking the position of holes, mortises and chases in the structure Item 1

Page 723: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

4 Identification; plates, discs, labels, tapes, bands, arrows, symbols, letters, numbers and Item 1

charts; as stated on drawings and in Specification

5 Testing and commissioning of entire installation Item 1

6 Preparation of as-built drawings Item 1

7 Preparation of operation and maintenance manuals Item 1

8 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

ADDITIONAL (As per Q&A 487)

1 ACTIVE COMPONENTS (AS PER Q&A 487) DISTRIBUTION CABINET nr 1

Total for COMMUNICATIONS

CARRIED TO SUMMARY

31 00 00 EARTHWORK

All works herein shall be completed in full compliance with the Drawings nr V-S001,VS002,

V-S003,V-S004,V-S005,V-S401and Specification.

31 10 00 Site Clearing

1 Site preparation, clearing site vegetation m2 175

31 23 16 Excavation

2 Excavating top soil for preservation, average depth 150mm. m2 175

3 Excavating pits( 15 nr), maximum depth ≤ 2.00m. m3 167

4 Excavating trenches for grade beams, width ≤ 0.3m m3 11

31 23 23 .13 Backfill

5 Filling to excavations, average thickness > 0.25 m, arising from excavated materials, all fill m3 128

Page 724: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

shall be compacted to 75% relative density for cohesion-less soils as per ASTM

D4254/ASTM D4293 or 95% maximum density as determined by ASTM D698 for cohesive

material, as per the Drawings and Specifications).

31 23 23.23 Compaction

6 Surface treatments, compacting bottom of excavation, compaction to meet 85% of m2 265

relative density for cohesion-less soils or 95% maximum density as determined by ASTM

D1557 for cohesive materials per the Drawings and Specifications)

31 23 16.26 Rock Removal

7 Disposal of excavated material, off site as stated in the Specification. m3 77

31 31 16 Termite Control

1 Termite control for the horizontal surface (method and type of treatment as per the m2 265

Drawings and Specifications)

2 Termite control for vertical surface (method and type of treatment as per the Drawings m2 295

and Specifications)

Additional Items

3 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not Item

mentioned here. Any such items not listed below shall be deemed to be included.

Total for EARTHWORK

CARRIED TO SUMMARY

ADJUSTMENT TO VILLA TYPE 4 FOR STAGGERS

04 00 00 - Masonry

04 22 00 - Concrete Unit Masonry

External walls

Page 725: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Option A - Semi Attahced End Terrce

1 300mm thick CMU wall, vertical, comprised with 150mm block work external side,

50mm insulation, 100mm block work internal side, (kind, quality and size of blocks, type

of bond, mix of motar etc. to be included as per the details and Specification )

5 Units x 50m2 m2 250

2 200mm thick CMU wall reinforced, 1 hour fire rated, vertical, (kind, quality and size of

blocks, type of bond, mix of motar etc. to be included as per the Specification)

5 Units x (-32) m2 m2 (160)

3 200mm thick 400mm high parapet CMU parapet wall at roof and second floor, vertical,

(kind, quality and size of blocks, type of bond, mix of motar etc. to be included as per the

Specification)

5 Units x 2m2 m2 10

4 300mm thick CMU wall, vertical, comprised with 150mm block work external side,

50mm insulation, 100mm block work internal side, (kind, quality and size of blocks, type

of bond, mix of motar etc. to be included as per the details and Specification )

5 Units x 43m2 m2 215

5 200mm thick CMU wall reinforced, 1 hour fire rated, vertical, (kind, quality and size of

blocks, type of bond, mix of motar etc. to be included as per the Specification)

5 Units x (25)m2 m2 (125)

6 200mm thick 400mm high parapet CMU parapet wall at roof and second floor, vertical,

(kind, quality and size of blocks, type of bond, mix of motar etc. to be included as per the

Specification)

5 Units x (0.0)m2 m2 0

Page 726: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for MASONRY

CARRIED TO SUMMARY

09 00 00 - FINISHES

09 24 00 Cement Plastering

External walls

Option A - Semi Attahced End Terrce

1 Self coloured rendering ( pre coloured mineral wall coating) for external walls at second

floor, roof and water tank area, width > 300mm, (thickness, kind, quality,compasition,

mix materials, nature of base, method of construction, layout and treatments, thermal

insulation, moisture resistant treatment, method of jointing, etc. as per the Drawings nr

V4-A201, V4-A501, V4-A907) and Specification).

5 Units x 78m2 m2 390

2 Self coloured rendering ( pre coloured mineral wall coating) for parapet walls at roof and

water tank area, width > 300mm, (thickness, kind, quality,compasition, mix materials,

nature of base, method of construction, layout and treatments, thermal insulation,

moisture resistant treatment, method of jointing, etc. as per the Drawings nr V4-A201,

V4-A501, V4-A907) and Specification).

5 Units x 3m2 m2 15

Option C - Semi Attahced End Terrce

3 Self coloured rendering ( pre coloured mineral wall coating) for external walls at second

floor, roof and water tank area, width > 300mm, (thickness, kind, quality,compasition,

mix materials, nature of base, method of construction, layout and treatments, thermal

insulation, moisture resistant treatment, method of jointing, etc. as per the Drawings nr

V4-A201, V4-A501, V4-A907) and Specification).

5 Units x 63m2 m2 315

4 Self coloured rendering ( pre coloured mineral wall coating) for parapet walls at roof

Page 727: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

and water tank area, width > 300mm, (thickness, kind, quality,compasition, mix

materials, nature of base, method of construction, layout and treatments, thermal

insulation, moisture resistant treatment, method of jointing, etc. as per the Drawings nr

V4-A201, V4-A501, V4-A907) and Specification).

5 Units x 1m2 m2 5

Total for FINISHES

CARRIED TO SUMMARY

03 00 00 Concrete

04 00 00 Masonry

05 00 00 Metal

06 00 00 Wood, Plastics and Composites

07 00 00 Thermal and Moisture Protection

08 00 00 Openings

09 00 00 Finishes

10 00 00 Specialties

11 00 00 Equipment

12 00 00 Furnishing

22 00 00 Plumbing

23 00 00 Heating, Ventilating and Air Conditioning (HVAC)

26 00 00 Electrical

27 00 00 Communications

31 00 00 Earthwork

SUBTOTAL

Page 728: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

54

SUBTOTAL

ADD/DEDUCT FOR STAGGERS

04 00 00 Masonry

09 00 00 Finishes

AMOUNT FOR VILLA TYPE V4 CARRIED TO SUMMARY

MULTIPLY BY 54 NR UNITS

Page 729: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Amount

164.00 2,132.00

380.00 14,820.00

296.00 7,992.00

144705.00 144,705.00

25.00 8,725.00

17.00 2,533.00

311.00 311.00

17.00 3,400.00

32.00 608.00

63.00 693.00

11.00 132.00

Page 730: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

US Dollar. 186,051.00

34.00 3,910.00

US Dollar. 3,910.00

163.00 1,956.00

226.00 1,582.00

143.00 2,717.00

Page 731: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

US Dollar. 6,255.00

5655.00 5,655.00

629.00 629.00

2166.00 2,166.00

841.00 841.00

Page 732: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

460.00 920.00

438.00 438.00

570.00 570.00

CF 11,219.00

BF 11,219.00

1536.00 1,536.00

130.00 130.00

474.00 474.00

353.00 353.00

Page 733: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

US Dollar. 13,712.00

5.00 385.00

5.00 360.00

2.00 336.00

22.00 1,496.00

22.00 902.00

37.00 5,624.00

3.00 456.00

CF 9,559.00

Page 734: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

BF 9,559.00

23.00 3,496.00

34.00 306.00

3802

US Dollar. 17,163.00

2806.00 2,806.00

953.00 3,812.00

Page 735: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

952.00 4,760.00

5037.00 5,037.00

CF 16,415.00

BF 16,415.00

5905.00 23,620.00

3193.00 9,579.00

452.00 904.00

904.00 2,712.00

Page 736: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

128.00 256.00

114.00 114.00

161.00 161.00

CF 53,761.00

BF 53,761.00

271.00 4,607.00

204.00 408.00

305.00 1,525.00

723.00 Unit Rate Only-Optional

Page 737: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

US Dollar. 60,301.00

55.00 440.00

22.00 2,200.00

21.00 2,499.00

CF 5,139.00

BF 5,139.00

55.00 10,725.00

32.00 2,304.00

51.00 2,142.00

32.00 3,488.00

Page 738: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

53.00 1,484.00

72.00 7,776.00

17.00 1,530.00

17.00 170.00

19.00 418.00

19.00 304.00

24.00 504.00

20.00 480.00

CF 36,464.00

BF 36,464.00

54.00 10,638.00

Page 739: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

56.00 616.00

56.00 1,344.00

11.00 2,970.00

11.00 825.00

11.00 231.00

11.00 3,652.00

Page 740: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

US Dollar. 56,740.00

21.00 84.00

22.00 88.00

35.00 140.00

17.00 68.00

31.00 124.00

54.00 54.00

76.00 76.00

1504.00 3,008.00

1609.00 1,609.00

CF 5,251.00

BF 5,251.00

Page 741: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1819.00 1,819.00

525.00 525.00

759.00 759.00

703.00 703.00

781.00 781.00

17.00 51.00

US Dollar. 9,889.00

Page 742: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

AS PER Q&A-77 NOT INCLUDED

IN THE SCOPE OF WORKS

465.00 465.00

AS PER Q&A-77 NOT INCLUDED

IN THE SCOPE OF WORKS

AS PER Q&A-77 NOT INCLUDED

IN THE SCOPE OF WORKS

US Dollar. 465.00

US Dollar. 0.00

Page 743: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

25.00 50.00

34.00 68.00

48.00 48.00

65.00 650.00

included in sanitary fixtures section 224000

included in sanitary fixtures section 224000

72.00 72.00

110.00 220.00

159.00 159.00

20.00 40.00

23.00 115.00

50.00 100.00

Page 744: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

366.00 366.00

CF 1,888.00

BF 1,888.00

49.00 980.00

43.00 387.00

38.00 532.00

22.00 550.00

17.00 612.00

16.00 880.00

29.00 58.00

1618.00 1,618.00

46.00 138.00

96.00 288.00

Page 745: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

46.00 92.00

96.00 96.00

11.00 132.00

17.00 170.00

29.00 638.00

29.00 493.00

CF 9,552.00

BF 9,552.00

27.00 108.00

Page 746: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

36.00 432.00

36.00 360.00

17.00 595.00

27.00 135.00

17.00 238.00

9.00 198.00

10.00 80.00

CF 11,698.00

BF 11,698.00

Page 747: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

275.00 550.00

300.00 600.00

322.00 644.00

192.00 1,152.00

38.00 152.00

313.00 1,252.00

202.00 404.00

171.00 684.00

43.00 43.00

769.00 769.00

As per the drawing it is integrated

with the Acrylic Countertop

41.00 41.00

292.00 584.00

As per Q&A-383, the sink bowl is

integrated with the Acrylic Countertop

CF 18,573.00

BF 18,573.00

Page 748: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

166.00 664.00

425.00 425.00

648.00 648.00

11.00 55.00

1703.00 1,703.00

470.00 470.00

INCLUDED

205.00 205.00

1195.00 1,195.00

INCLUDED

INCLUDED

Page 749: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

US Dollar. 23,938.00

30.00 1,950.00

12.00 6,204.00

Page 750: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

66.00 66.00

85.00 255.00

95.00 95.00

CF 8,570.00

BF 8,570.00

23.00 23.00

26.00 52.00

28.00 28.00

133.00 133.00

162.00 810.00

Page 751: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

As per Q&A-361 item is deleted

67.00 67.00

74.00 74.00

78.00 78.00

78.00 78.00

CF 9,913.00

BF 9,913.00

101.00 101.00

54.00 54.00

Page 752: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

55.00 55.00

60.00 60.00

60.00 60.00

75.00 75.00

139.00 139.00

170.00 510.00

170.00 170.00

76.00 228.00

76.00 76.00

44.00 132.00

44.00 132.00

2971.00 2,971.00

2971.00 2,971.00

2277.00 2,277.00

2277.00 2,277.00

Page 753: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2277.00 2,277.00

1690.00 1,690.00

CF 26,168.00

BF 26,168.00

737.00 737.00

737.00 737.00

INCLUDED

205.00 205.00

INCLUDED

INCLUDED

INCLUDED

Page 754: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

US Dollar. 27,847.00

1877.00 1,877.00

638.00 638.00

24.00 24.00

45.00 45.00

412.00 412.00

322.00 322.00

129.00 129.00

523.00 523.00

CF 3,970.00

BF 3,970.00

Page 755: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2150.00 2,150.00

1256.00 1,256.00

567.00 567.00

21.00 21.00

32.00 32.00

276.00 276.00

266.00 266.00

111.00 111.00

347.00 347.00

CF 8,996.00

BF 8,996.00

Page 756: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1152.00 1,152.00

1939.00 1,939.00

10.00 110.00

CF 12,197.00

BF 12,197.00

12.00 60.00

20.00 20.00

11.00 55.00

9.00 90.00

Page 757: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

19.00 323.00

210.00 630.00

16.00 96.00

16.00 48.00

47.00 282.00

204.00 2,244.00

CF 16,045.00

BF 16,045.00

208.00 3,120.00

110.00 1,430.00

225.00 900.00

189.00 756.00

110.00 220.00

184.00 552.00

102.00 408.00

250.00 2,000.00

222.00 1,110.00

Page 758: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 26,541.00

BF 26,541.00

included

included

included

included

included

92.00 276.00

39.00 663.00

US Dollar. 27,480.00

Page 759: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

47.00 282.00

34.00 136.00

34.00 34.00

34.00 204.00

1576.00 1,576.00

AS PER Q&A # 317 NOT IN THE SCOPE

AS PER Q&A # 317 NOT IN THE SCOPE

9.00 1,440.00

See Master plan BOQ

209.00 209.00

458.00 458.00

CF 4,339.00

BF 4,339.00

109.00 109.00

326.00 326.00

9.00 180.00

Page 760: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1084.00 1,084.00

10.00 220.00

68.00 476.00

62.00 62.00

97.00 97.00

68.00 68.00

80.00 160.00

68.00 68.00

3047.00 3,047.00

included in the above

CF 10,236.00

BF 10,236.00

9.00 540.00

9.00 90.00

included

Page 761: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

included

included

included

included

2914.00 2,914.00

US Dollar. 13,780.00

2.00 350.00

3.00 525.00

8.00 1,336.00

10.00 110.00

12.00 1,536.00

Page 762: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3.00 795.00

4.00 308.00

CF 4,960.00

BF 4,960.00

1.00 265.00

0.00 0.00

US Dollar 5,225.00

Page 763: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

83.00 20,750.00

43.00 -6,880.00

35.00 350.00

83.00 17,845.00

43.00 -5,375.00

Page 764: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

US Dollar 26,690.00

29.00 11,310.00

29.00 435.00

29.00 9,135.00

Page 765: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

29.00 145.00

US Dollar 21,025.00

186,051.00

3,910.00

6,255.00

13,712.00

13,361.00

60,301.00

56,740.00

9,889.00

465.00

0.00

23,938.00

27,847.00

27,480.00

13,780.00

5,225.00

448,954.00

Page 766: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

###

###

0.00

0.00

US Dollar ###

Page 767: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Item Nr. Description Unit Qty

03 00 00 - CONCRETE

03 11 13 Structural Cast-in-Place Concrete Forming

1 Plain concrete 20MPa for blinding thickness 100mm for footing and 50mm under slab on grade m3 622

03 31 00 Structural Concrete

2 Reinforced concrete 35Mpa for strip footing m3 1156

3 Reinforce concrete 35MPa for slab on grade with 7Ø8 / Liner meter thickness 150mm m3 968

Precast Concrete

4 Precast concrete for super structure item 1

Concrete Topping

5 Sand cement concrete screed with wire mesh thick 50mm for floors above m2 12216

hollow core slabs.

6 Sand cement foam concrete to slab at roof average 75mm thick m2 6206

7 Sealed Concrete for beds at roof thick 350mm m3 24

8 Sealed Concrete for floors to receive finish thick 50mm m2 6010

03 30 53 - Miscellaneous Cast-in-situ Concrete

9 300mm wide x 200mm high reinforced concrete 35 Mpa for lintel m 397

10 Ditto - 200mm. m 66

11 Ditto - 100mm. m 108

Total for CONCRETE

CARRIED TO SUMMARY

04 00 00 - Masonry

04 22 00 - Concrete Unit Masonry

Page 768: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Internal walls and Partitions

1 250mm thick CMU wall , type 23, m2 211

2 250mm thick CMU wall , 2hr fire rated, rating Type 13 m2 325

3 200mm thick CMU wall , type 22, m2 662

4 200mm thick CMU wall , 2hr fire rated, type 12A m2 840

5 200mm thick CMU wall , 1hr fire rated, type 12A m2 2500

6 100mm thick CMU wall reinforced, type 2A, m2 302

7 100mm thick CMU wall reinforced, type 2, m2 9

8 100mm thick CMU wall reinforced, 1hr fire rated, m2 29

9 100mm thick CMU wall 2hr fire rated Type 12A m2 20

10 1150mm thick CMU wall 2hr fire rated Type 12A m2 24

Total for MASONRY

CARRIED TO SUMMARY

05 00 00 METALS

All metal works herein shall be completed in full compliance with the Drawings nr RBA401,

RB-A903 and Specification.

05 70 00 Decorative Metal

1 Supply and fix 50mm diameter stainless steel hand rails 1100mm high for staircase m 9

including but not limited to 12mm diameter stainless steel balustrade, 40mm square

stainless steel post with 50mm x 120mm base plate, floor mounted, kind, quality,

fittings, fixtures, accessories as shown on Drawings and as per Specification.

2 Supply and fix 50mm diameter stainless steel hand rails for staircase, wall mounted, m 13

kind, quality, fittings, fixtures, accessories as shown on Drawings and as per Specification.

3 Supply and fix toughened safety glass guard rail for staircase, 1100mm high, floor m 43

mounted, kind, quality, fittings, fixtures, accessories as shown on Drawings and as per

Specification.

05 00 00 Metals

Page 769: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Additional Items

4 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

As per Question and Answer No. (65)

4.1 Galvanized steel ladder at Elevator Pit, size 350 x 2500mm high nr 1

Total for METALS

CARRIED TO SUMMARY

06 00 00 WOOD, PLASTICS, AND COMPOSITES

06 61 16 Solid Surfacing Fabrications

1 Supply and fix solid acrylic counter top and shelves 7500mm length 750mm wide 900 nr 1

high including but not limited to recess grip profile coloured anodized silver, shelves,

doors, hardware sets and all other accessories as shown in the Drawing nr RB-A904 and

Specification.

2 Supply and fix solid acrylic counter top shaped 2655mm long 800mm wide with 3 nr of nr 2

opening for wash basin as shown in the Drawing nr RB-A909, RB-A910 and Specification.

3 Supply and fix solid acrylic counter top shaped 1800mm long 600mm wide with 2 nr of nr 2

opening for wash basin as shown in the Drawing nr RB-A909, RB-A910 and Specification.

4 Supply and fix solid acrylic counter top shaped 1900mm long 600mm wide with 3 nr of nr 2

opening for wash basin as shown in the Drawing nr RB-A909, RB-A910 and Specification.

5 Supply and fix solid acrylic counter top shaped 3750mm long 575mm wide with 4 nr of nr 2

opening for wash basin as shown in the Drawing nr RB-A909, RB-A910 and Specification.

6 Supply and fix solid acrylic counter top shaped 1850mm long 575mm wide with 2 nr of nr 2

opening for wash basin as shown in the Drawing nr RB-A909, RB-A910 and Specification.

7 Supply and fix solid acrylic counter top shaped 2100mm long 575mm wide with 2 nr of nr 1

opening for wash basin as shown in the Drawing nr RB-A909, RB-A910 and Specification.

Page 770: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

8 Supply and fix solid acrylic counter top shaped 2100mm long 575mm wide with 2 nr of nr 1

opening for wash basin as shown in the Drawing nr RB-A909, RB-A910 and Specification.

WOOD, PLASTICS, AND COMPOSITES (Cont'd)

06 00 00 Wood, Plastics, and Composites

Additional Items

1 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

As per Question and Answer No. (336)

Pantry at Room G36

1.1 Counter with basin (9300 x 600) nr 1

1.2 Counter (1700 x 600mm) nr 1

Total for WOOD, PLASTICS, AND COMPOSITES

CARRIED TO SUMMARY

07 00 00 THERMAL AND MOISTURE PROTECTION

07 10 00 Damp proofing and Waterproofing

Substructure Waterproofing

All works herein shall be completed in full incompliance with the Drawings nr RBS001,

RB-S002,RB-S003,RB-S101, RB-S102, RB-S201, RB-S202, RB-S203, RB-S204, RBS401,

RB-S402, RB-S501, RB-S502, RB-S801 and Specification.

Page 771: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1 Two coats of bitumen paint for sub structure including elevator pit walls for vertical surface. m2 3413

2 Ditto for horizontal surface m2 2383

3 Waterproofing works for substructure with vapour barrier 250 microns, horizontal m2 7042

surface as per the Drawings and Specification).

THERMAL AND MOISTURE PROTECTION (Cont'd)

Wet Area Waterproofing / Roof Waterproofing

All works herein shall be completed in full compliance with the Drawings nr RB-A909, RBA909

and Specification.

1 Waterproofing works for wet area, vertical surface m2 390

as per the Drawings and Specification.

2 Waterproofing works for wet area, horizontal surface, m2 197

as per the Drawings and Specification.

3 Waterproofing membrane for roof and balcony, horizontal surface, m2 6577

as per the Drawings and Specification.

4 Geotextile layer for roof and balcony water proofing works, horizontal surface, m2 6577

as per the Drawings and Specification.

5 100mm thick insulation for water proofing works at roof and balcony water proofing m2 6577

works, horizontal surface, as per the Drawings and Specification.

07 90 00 Thermal and Moisture Protection

6 Supply and execute expansion joint at sides of walls and columns as detailed in drawings m 2507

including flexcell sheets 18mm thick, mastic 20mm thick & cover the joints with

Aluminium strip size 75x6mm or Aluminium angle 57x57x6mm fixed to Aluminium strip

Page 772: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

37x6mm screwed to the walls or the soffits from one side, as per drawings,

specifications.

7 Supply and execute expansion joint on the floors as detailed in drawings including m 285

flexcell sheets 18mm thick, 20x30mm mastic, 2 Nos. of galvanized steel angle size

75x75x5mm & 1.0m wide strip of self adhesive membrane 4.0kg/m2 as per

specifications, and drawings.

THERMAL AND MOISTURE PROTECTION (Cont'd)

07 95 13 Expansion Joint Cover Assemblies

1 Supply and fix expansion joint cover 30mm wide, kind, quality, fittings, fixtures, m 270

accessories as shown on Drawings nr RB-A201, RB-A202, RB-A203 and as per

Specification.

Total for THERMAL AND MOISTURE PROTECTION

CARRIED TO SUMMARY

08 00 00 OPENINGS

All works herein shall be completed in full compliance with the Doors & Windows Note

Schedule Drawings nr RB-A801, RB-A802, RB-A803, and Specification.

Note: Notwithstanding the Provisions of the Standard Method of Measurement, door

Page 773: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

sets including doors, frames, vision panels, decoration and ironmongery have been

measured as a composite item and the Contractor should make due reference to the

drawings and specification. No claim for lack or want of knowledge will be entertained

08 11 00 Metal Doors and Frames

1 Supply and fix steel door, 1000mm wide x 2200mm high including frame, type D9, nr 4

finished with and including paint, all accessories and hardware including but not limited

to hinges BBS type, outside door lock, lever handles and latch, wall stop, roses and

escutcheons as stated on the drawings and in the Specification.

2 Supply and fix steel door, 1000mm wide x 2200mm high including frame, type D9A, nr 1

finished with and including paint, all accessories and hardware including but not limited

to hinges BBS type, outside door lock, lever handles and latch, wall stop, roses and

escutcheons as stated on the drawings and in the Specification.

3 Supply and fix steel door, 1500mm wide x 2200mm high including frame, type D15A, nr 1

finished with and including paint, all accessories and hardware including but not limited

to hinges BBS type, outside door lock, lever handles and latch, wall stop, roses and

escutcheons as stated on the drawings and in the Specification.

OPENINGS(Cont'd)

1 Supply and fix steel door, 2000mm wide x 2200mm high including frame, type D16, nr 1

finished with and including paint, all accessories and hardware including but not limited

to hinges BBS type, outside door lock, lever handles and latch, wall stop, roses and

escutcheons as stated on the drawings and in the Specification.

2 Supply and fix steel door, 1000mm wide x 2200mm high, type D18, finished with and nr 1

including paint, all accessories and hardware including but not limited to hinges BBS

type, inside door lock, lever handles and latch, wall stop, roses and escutcheons as

stated on the drawings and in the Specification.

3 Supply and fix steel door, 1000mm wide x 2200mm high, type D22, finished with and nr 4

including paint, all accessories and hardware including but not limited to hinges BBS

type, inside door lock, lever handles and latch, wall stop, roses and escutcheons as

stated on the drawings and in the Specification.

4 Supply and fix steel door, 1000mm wide x 2200mm high, type D22A, finished with and nr 1

including paint, all accessories and hardware including but not limited to hinges BBS

type, inside door lock, lever handles and latch, wall stop, roses and escutcheons as

stated on the drawings and in the Specification.

5 Supply and fix steel door, 800mm wide x 2200mm high, type D24, finished with and nr 1

Page 774: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

including paint, all accessories and hardware including but not limited to hinges BBS

type, outside door lock, lever handles and latch, wall stop, roses and escutcheons as

stated on the drawings and in the Specification.

6 Supply and fix steel door, 800mm wide x 2200mm high, type D24A, finished with and nr 1

including paint, all accessories and hardware including but not limited to hinges BBS

type, outside door lock, lever handles and latch, wall stop, roses and escutcheons as

stated on the drawings and in the Specification.

OPENINGS(Cont'd)

1 Supply and fix steel door, 800mm wide x 2200mm high, type D26, finished with and nr 2

including paint, all accessories and hardware including but not limited to hinges BBS

type, 10side door lock, lever handles and latch, wall stop, roses and escutcheons as

stated on the drawings and in the Specification.

08 11 16 Aluminum Doors and Frames

2 Supply and fix aluminium door with fixed glazed panel, 1000mm wide x 2500mm high nr 14

with 12mm laminated tempered glass including frame, type D6, finished with and

including paint, all accessories and hardware including but not limited to hinges BBS

type, outside and inside door lock, lever handles and latch, wall stop, roses, weather

stripping and escutcheons as stated on the drawings and in in the Specification.

3 Supply and fix glass door, 800mm wide x 2200mm high including frame, type D7, nr 6

finished with and including paint, all accessories and hardware including but not limited

to hinges BBS type, inside door lock, lever handles and latch, wall stop, roses and

escutcheons as stated on the drawings and in the Specification.

4 Supply and fix wooden door, 800mm wide x 2200mm high including frame, type D14, nr 4

finished with and including paint, all accessories and hardware including but not limited

to hinges BBS type, outside door lock, lever handles and latch, wall stop, roses and

escutcheons as stated on the drawings and in the Specification.

08 14 00 - Wood Doors

5 Supply and fix wooden and glass door (12mm laminated tempered glass) door, 1500mm nr 7

wide x 2200mm high including frame, type D1,20 minutes fire rated, finished with and

including paint, automatic flush bolt for inactive door leaf, all accessories and hardware

including but not limited to hinges BBS type, inside door lock, lever handles and latch,

wall stop, roses and escutcheons as stated on the drawings and in the Specification.

Page 775: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

OPENINGS(Cont'd)

1 Supply and fix wooden and glass door (12mm laminated tempered glass), 1500mm wide nr 24

x 2500mm high including frame, type D2, finished with and including paint, automatic

flush bolt for inactive door leaf, weather stripping, all accessories and hardware

including but not limited to hinges BBS type, outside door lock, lever handles and latch,

wall stop, roses and escutcheons as stated on the drawings and in the Specification.

2 Supply and fix wooden and glass door (12mm laminated tempered glass), 1500mm wide nr 5

x 2500mm high including frame, type D2A, finished with and including paint, automatic

flush bolt for inactive door leaf, weather stripping, all accessories and hardware

including but not limited to hinges BBS type, outside door lock, lever handles and latch,

wall stop, roses and escutcheons as stated on the drawings and in the Specification.

3 Supply and fix wooden and glass door (12mm laminated tempered glass), 1000mm wide nr 3

x 2500mm high including frame, type D3, finished with and including paint, all

accessories and hardware including but not limited to hinges BBS type, inside door lock,

lever handles and latch, wall stop, roses and escutcheons as stated on the drawings and

in the Specification.

4 Supply and fix wooden and glass door, 2000mm wide x 2500mm high including frame, nr 7

type D4, finished with and including paint, automatic flush bolt for inactive door leaf,

weather stripping, all accessories and hardware including but not limited to hinges BBS

type, outside door lock, lever handles and latch, wall stop, roses and escutcheons as

stated on the drawings and in the Specification.

5 Supply and fix wooden teak decorative veneered door, 1500mm wide x 2500mm high nr 2

including frame, type D5, finished with and including paint, automatic flush bolt for

inactive door leaf, weather stripping, all accessories and hardware including but not

limited to hinges BBS type, inside door lock, lever handles and latch, wall stop, roses and

escutcheons as stated on the drawings and in the Specification.

Page 776: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

OPENINGS(Cont'd)

1 Supply and fix wooden teak veneered door, 1500mm wide x 2500mm high nr 4

including frame, type D5A, finished with and including paint, automatic flush bolt for

inactive door leaf, weather stripping, all accessories and hardware including but not

limited to hinges BBS type, inside door lock, lever handles and latch, wall stop, roses and

escutcheons as stated on the drawings and in the Specification.

2 Supply and fix wooden teak veneered door, 1500mm wide x 2500mm high nr 2

including frame, type D5B, finished with and including paint, automatic flush bolt for

inactive door leaf, weather stripping, all accessories and hardware including but not

limited to hinges BBS type, inside door lock, lever handles and latch, wall stop, roses and

escutcheons as stated on the drawings and in the Specification.

4 Supply and fix wooden door, 800mm wide x 2200mm high including frame, type D8, nr 5

finished with and including paint, automatic flush bolt for inactive door leaf, weather

stripping, all accessories and hardware including but not limited to hinges BBS type,

outside door lock, lever handles and latch, wall stop, roses and escutcheons as stated on

the drawings and in the Specification.

5 Supply and fix wooden door, 800mm wide x 2200mm high including frame, type D8A, nr 2

finished with and including paint, automatic flush bolt for inactive door leaf, weather

stripping, all accessories and hardware including but not limited to hinges BBS type,

outside door lock, lever handles and latch, wall stop, roses and escutcheons as stated on

the drawings and in the Specification.

6 Supply and fix wooden door, 800mm wide x 2200mm high including frame, type D10, nr 7

finished with and including paint, automatic flush bolt for inactive door leaf, weather

stripping, all accessories and hardware including but not limited to hinges BBS type,

outside door lock, lever handles and latch, wall stop, roses and escutcheons as stated on

the drawings and in the Specification.

OPENINGS(Cont'd)

1 Supply and fix wooden door, 800mm wide x 2200mm high including frame, type D10A, nr 7

finished with and including paint, automatic flush bolt for inactive door leaf, weather

stripping, all accessories and hardware including but not limited to hinges BBS type,

outside door lock, lever handles and latch, wall stop, roses and escutcheons as stated on

the drawings and in the Specification.

Page 777: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2 Supply and fix wooden door, 800mm wide x 2200mm high including frame, type D10B, nr 1

finished with and including paint, automatic flush bolt for inactive door leaf, weather

stripping, all accessories and hardware including but not limited to hinges BBS type,

outside door lock, lever handles and latch, wall stop, roses and escutcheons as stated on

the drawings and in the Specification.

3 Supply and fix wooden door, 700mm+FB wide x 2200mm high including frame, type D11, nr 56

finished with and including paint, automatic flush bolt for inactive door leaf, weather

stripping, all accessories and hardware including but not limited to hinges BBS type,

inside door lock, lever handles and latch, wall stop, roses and escutcheons as stated on

the drawings and in the Specification.

4 Supply and fix wooden door, 1000mm wide x 2200mm high including frame, type D12, nr 6

finished with and including paint, automatic flush bolt for inactive door leaf, weather

stripping, all accessories and hardware including but not limited to hinges BBS type,

inside door lock, lever handles and latch, wall stop, roses and escutcheons as stated on

the drawings and in the Specification.

6 Supply and fix wooden door, 800mm wide x 2200mm high including frame, type D17, nr 1

finished with and including paint, all accessories and hardware including but not limited

to hinges BBS type, outside door lock, lever handles and latch, wall stop, roses and

escutcheons as stated on the drawings and in the Specification.

OPENINGS(Cont'd)

1 Supply and fix wooden door, 800mm wide x 2200mm high including frame, type D17A, nr 1

finished with and including paint, all accessories and hardware including but not limited

to hinges BBS type, outside door lock, lever handles and latch, wall stop, roses and

escutcheons as stated on the drawings and in the Specification.

2 Supply and fix wooden door, 800mm wide x 2200mm high including frame, type D19, nr 2

finished with and including paint, all accessories and hardware including but not limited

to hinges BBS type, outside door lock, lever handles and latch, wall stop, roses and

escutcheons as stated on the drawings and in the Specification.

3 Supply and fix wooden door, 800mm wide x 2200mm high including frame, type D20, nr 1

finished with and including paint, weather stripping, all accessories and hardware

including but not limited to hinges BBS type, outside door lock, lever handles and latch,

wall stop, roses and escutcheons as stated on the drawings and in the Specification.

4 Supply and fix wooden door, 1000mm wide x 2200mm high including frame, type D20A, nr 1

finished with and including paint, all accessories and hardware including but not limited

Page 778: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

to hinges BBS type, outside door lock, lever handles and latch, wall stop, roses and

escutcheons as stated on the drawings and in the Specification.

5 Supply and fix wooden door, 1000mm wide x 2200mm high including frame, type D21, nr 2

finished with and including paint, all accessories and hardware including but not limited

to hinges BBS type, outside door lock, lever handles and latch, wall stop, roses and

escutcheons as stated on the drawings and in the Specification.

6 Supply and fix wooden door, 1000mm wide x 2200mm high including frame, type D23, nr 2

finished with and including paint, all accessories and hardware including but not limited

to hinges BBS type, outside door lock, lever handles and latch, wall stop, roses and

escutcheons as stated on the drawings and in the Specification.

OPENINGS(Cont'd)

1 Supply and fix wooden door, 800mm wide x 2200mm high including frame, type D25, nr 1

finished with and including paint, all accessories and hardware including but not limited

to hinges BBS type, inside door lock, lever handles and latch, wall stop, roses and

escutcheons as stated on the drawings and in the Specification.

2 Supply and fix wooden door, 800mm wide x 2200mm high including frame, type D25A, nr 9

finished with and including paint, all accessories and hardware including but not limited

to hinges BBS type, inside door lock, lever handles and latch, wall stop, roses and

escutcheons as stated on the drawings and in the Specification.

08 33 23 Overhead Coiling Doors

3 Supply and fix rolling shutter door, 4500mm wide x 2900mm high including frame, nr 1

finished with and including paint, all accessories and hardware as stated on the drawings

and in the Specification.

08 51 13 Aluminum Windows

4 Supply and fix aluminium double glazed window, 1200mm wide x 3000mm high, type nr 1

W1, finished, all accessories and hardware including but not limited to hinges, handle,

lock, weather tight strip etc. as stated in the Drawings and Specification.

5 Supply and fix aluminium double glazed window, 5400mm wide x 3000mm high, type nr 2

W2, finished, all accessories and hardware including but not limited to hinges, handle,

lock, weather tight strip etc. as stated in the Drawings and Specification.

Page 779: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

6 Supply and fix aluminium double glazed window, 5500mm wide x 3000mm high, type nr 2

W3, finished, all accessories and hardware including but not limited to hinges, handle,

lock, weather tight strip etc. as stated in the Drawings and Specification.

7 Supply and fix aluminium double glazed window, 6000mm wide x 3000mm high, type nr 1

W4, finished, all accessories and hardware including but not limited to hinges, handle,

lock, weather tight strip etc. as stated in the Drawings and Specification.

OPENINGS(Cont'd)

1 Supply and fix aluminium double glazed window, 3600mm wide x 3000mm high, type nr 1

W5, finished, all accessories and hardware including but not limited to hinges, handle,

lock, weather tight strip etc. as stated in the Drawings and Specification.

2 Supply and fix aluminium double glazed window, 6000mm wide x 3000mm high, type nr 1

W6, finished, all accessories and hardware including but not limited to hinges, handle,

lock, weather tight strip etc. as stated in the Drawings and Specification.

3 Supply and fix aluminium double glazed window, 5800mm wide x 3000mm high, type nr 1

W7, finished, all accessories and hardware including but not limited to hinges, handle,

lock, weather tight strip etc. as stated in the Drawings and Specification.

4 Supply and fix aluminium double glazed window, 5300mm wide x 3000mm high, type nr 2

W8, finished, all accessories and hardware including but not limited to hinges, handle,

lock, weather tight strip etc. as stated in the Drawings and Specification.

5 Supply and fix aluminium double glazed window, 3000mm wide x 3000mm high, type nr 14

W9, finished, all accessories and hardware including but not limited to hinges, handle,

lock, weather tight strip etc. as stated in the Drawings and Specification.

6 Supply and fix aluminium double glazed window, 2000mm wide x 2000mm high, type nr 2

W10, finished, all accessories and hardware including but not limited to hinges, handle,

lock, weather tight strip etc. as stated in the Drawings and Specification.

7 Supply and fix aluminium double glazed window, 7750mm wide x 900mm high, type nr 1

W11, finished, all accessories and hardware including but not limited to hinges, handle,

lock, weather tight strip etc. as stated in the Drawings and Specification.

8 Supply and fix aluminium double glazed window, 1800mm wide x 1600mm high, type nr 2

W12, finished, all accessories and hardware including but not limited to hinges, handle,

lock, weather tight strip etc. as stated in the Drawings and Specification.

Page 780: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

OPENINGS(Cont'd)

1 Supply and fix aluminium double glazed window, 5175mm wide x 1600mm high, type nr 1

W13, finished, all accessories and hardware including but not limited to hinges, handle,

lock, weather tight strip etc. as stated in the Drawings and Specification.

2 Supply and fix aluminium double glazed window, 5200mm wide x 1600mm high, type nr 2

W14, finished, all accessories and hardware including but not limited to hinges, handle,

lock, weather tight strip etc. as stated in the Drawings and Specification.

3 Supply and fix aluminium double glazed window, 1500mm wide x 1500mm high, type nr 3

W15, finished, all accessories and hardware including but not limited to hinges, handle,

lock, weather tight strip etc. as stated in the Drawings and Specification.

4 Supply and fix aluminium double glazed window, 5400mm wide x 3000mm high, type nr 1

W16, finished, all accessories and hardware including but not limited to hinges, handle,

lock, weather tight strip etc. as stated in the Drawings and Specification.

5 Supply and fix aluminium double glazed window, 5400mm wide x 900mm high, type nr 1

W16, finished, all accessories and hardware including but not limited to hinges, handle,

lock, weather tight strip etc. as stated in the Drawings and Specification.

6 Supply and fix aluminium double glazed window, 5500mm wide x 3000mm high, type nr 1

W17, finished, all accessories and hardware including but not limited to hinges, handle,

lock, weather tight strip etc. as stated in the Drawings and Specification.

7 Supply and fix aluminium double glazed window, 5500mm wide x 900mm high, type nr 1

W17, finished, all accessories and hardware including but not limited to hinges, handle,

lock, weather tight strip etc. as stated in the Drawings and Specification.

OPENINGS(Cont'd)

1 Supply and fix aluminium double glazed window, 4600mm wide x 5000mm high, type nr 1

W18, finished, all accessories and hardware including but not limited to hinges, handle,

lock, weather tight strip etc. as stated in the Drawings and Specification.

2 Supply and fix aluminium double glazed window, 6200mm wide x 3000mm high, type nr 2

W19, finished, all accessories and hardware including but not limited to hinges, handle,

lock, weather tight strip etc. as stated in the Drawings and Specification.

Page 781: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3 Supply and fix aluminium double glazed window, 8250mm wide x 3000mm high, type nr 1

W20, finished, all accessories and hardware including but not limited to hinges, handle,

lock, weather tight strip etc. as stated in the Drawings and Specification.

4 Supply and fix aluminium double glazed window, 4500mm wide x 3000mm high, type nr 2

W21, finished, all accessories and hardware including but not limited to hinges, handle,

lock, weather tight strip etc. as stated in the Drawings and Specification.

5 Supply and fix aluminium double glazed window, 5500mm wide x 3000mm high, type nr 1

W22, finished, all accessories and hardware including but not limited to hinges, handle,

lock, weather tight strip etc. as stated in the Drawings and Specification.

6 Supply and fix aluminium double glazed window, 1300mm wide x 3000mm high, type nr 2

W23, finished, all accessories and hardware including but not limited to hinges, handle,

lock, weather tight strip etc. as stated in the Drawings and Specification.

7 Supply and fix aluminium double glazed window, 4950mm wide x 3000mm high, type nr 1

W24, finished, all accessories and hardware including but not limited to hinges, handle,

lock, weather tight strip etc. as stated in the Drawings and Specification.

8 Supply and fix aluminium double glazed window, 4925mm wide x 3000mm high, type nr 1

W25, finished, all accessories and hardware including but not limited to hinges, handle,

lock, weather tight strip etc. as stated in the Drawings and Specification.

OPENINGS(Cont'd)

1 Supply and fix aluminium double glazed window, 5500mm wide x 3000mm high, type nr 1

W26, finished, all accessories and hardware including but not limited to hinges, handle,

lock, weather tight strip etc. as stated in the Drawings and Specification.

2 Supply and fix aluminium double glazed window, 5200mm wide x 2800mm high, type nr 1

W27, finished, all accessories and hardware including but not limited to hinges, handle,

lock, weather tight strip etc. as stated in the Drawings and Specification.

3 Supply and fix aluminium double glazed window, 5175mm wide x 2800mm high, type nr 1

W28, finished, all accessories and hardware including but not limited to hinges, handle,

lock, weather tight strip etc. as stated in the Drawings and Specification.

4 Supply and fix aluminium double glazed window, 4950mm wide x 2800mm high, type nr 1

W29, finished, all accessories and hardware including but not limited to hinges, handle,

Page 782: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

lock, weather tight strip etc. as stated in the Drawings and Specification.

5 Supply and fix aluminium double glazed window, 4925mm wide x 2800mm high, type nr 1

W30, finished, all accessories and hardware including but not limited to hinges, handle,

lock, weather tight strip etc. as stated in the Drawings and Specification.

6 Supply and fix aluminium double glazed window, 5725mm wide x 3000mm high, type nr 2

W31, finished, all accessories and hardware including but not limited to hinges, handle,

lock, weather tight strip etc. as stated in the Drawings and Specification.

7 Supply and fix aluminium double glazed window, 7445mm wide x 3000mm high, type nr 2

W32, finished, all accessories and hardware including but not limited to hinges, handle,

lock, weather tight strip etc. as stated in the Drawings and Specification.

OPENINGS(Cont'd)

08 83 00 Mirrors

1 Supply and fix fixed mirror 600mm width x 900mm high for wet areas (size, kind, quality, nr 6

surface treatment, method of jointing, etc. as per the Drawings nr RB-A902, RB-A903 and

Specification).

2 Supply and fix fixed mirror 2655mm width x 1100mm high for wet areas (size, kind, nr 2

quality, surface treatment, method of jointing, etc. as per the Drawings nr RB-A902, RBA903

and Specification).

3 Supply and fix fixed mirror 1800mm width x 1100mm high for wet areas (size, kind, nr 2

quality, surface treatment, method of jointing, etc. as per the Drawings nr RB-A902, RBA903

and Specification).

4 Supply and fix fixed mirror 1900mm width x 1100mm high for wet areas (size, kind, nr 2

quality, surface treatment, method of jointing, etc. as per the Drawings nr RB-A902, RBA903

and Specification).

5 Supply and fix fixed mirror 3750mm width x 1100mm high for wet areas (size, kind, nr 2

quality, surface treatment, method of jointing, etc. as per the Drawings nr RB-A902, RBA903

and Specification).

6 Supply and fix fixed mirror 1850mm width x 1100mm high for wet areas (size, kind, nr 2

quality, surface treatment, method of jointing, etc. as per the Drawings nr RB-A902, RBA903

and Specification).

Page 783: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

7 Supply and fix fixed mirror 2100mm width x 1100mm high for wet areas (size, kind, nr 1

quality, surface treatment, method of jointing, etc. as per the Drawings nr RB-A902, RBA903

and Specification).

8 Supply and fix fixed mirror 1500mm width x 1100mm high for wet areas (size, kind, nr 1

quality, surface treatment, method of jointing, etc. as per the Drawings nr RB-A902, RBA903

and Specification).

OPENINGS(Cont'd)

08 60 00 Roof Windows and Skylights

1 Supply and fix skylight 12800mm length x 1300mm wide at roof (size, kind, quality, fixing nr 7

details, surface treatment, method of jointing, etc. as per the Drawings nr RB-A903, RBA302

and Specification).

2 Supply and fix skylight 11800mm length x 1300mm wide at roof (size, kind, quality, fixing nr 7

details, surface treatment, method of jointing, etc. as per the Drawings nr RB-A903, RBA302

and Specification).

3 Supply and fix skylight 1300mm length x 1300mm wide at roof (size, kind, quality, fixing nr 2

details, surface treatment, method of jointing, etc. as per the Drawings nr RB-A903, RBA302

and Specification).

4 Supply and fix skylight 2300mm length x 1300mm wide at roof (size, kind, quality, fixing nr 1

details, surface treatment, method of jointing, etc. as per the Drawings nr RB-A903, RBA302

and Specification).

08 00 00 Openings

Additional Items

5 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

As per Question and Answer No (337)

5.1 Folding Door at Room No. GF-77 & 78 nr 2

Page 784: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for OPENINGS

CARRIED TO SUMMARY

09 00 00 - FINISHES

09 24 00 Cement Plastering

1 15mm thick internal plastering for walls to receive paint m2 7363

2 Ditto - for walls to receive tiling at wet areas, m2 732

FINISHES (Cont'd)

09 30 13 Ceramic Tiling

Floor Tiling

1 Glazed porcelain stoneware tile flooring (type - FT4), size 600mm x 600mm, m2 3162

2 Glazed porcelain stoneware tile flooring (type - FT5), size 600mm x 600mm, m2 196

3 Colorbody fine porcelain stoneware tile flooring (type - FT6), size 600mm x 600mm, m2 194

4 Terrazo tile flooring (type - FT9), size 400mm x 400mm, m2 111

5 Terrazo tiles, 400x400mm at roof m2 6577

Wall tiling

6 Mosaic tile (type WT5) 100mm x 300mm size for walls, m2 680

7 Glazed porcelain stoneware tile (type WT6) size 325mm x 977mm size for toilets and m2 503

bathroom walls,

Page 785: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

FINISHES (Cont'd)

Skirting

1 MDF skirting 100mm height, m 1385

2 Porcelain skirting 100mm height, m 30

Stair Finish

3 Glazed porcelain stoneware tile tread (type - FT4), size 230mm wide x 1350mm length, m 60

4 Glazed porcelain stoneware tile for riser (type - F41), size 160mm high x 1350mm length, m 98

Threshold

5 Porcelain stoneware for riser (type - FT2), size 160mm high x 1100mm length, m 71

FINISHES (Cont'd)

09 50 00 Ceilings

1 Supply and install gypsum ceiling, depth of suspension 500 - 1000 mm m2 3387

as per the Drawings nr RB-A906,RB-A803

2 Supply and install Moisture resistant gypsum ceiling for toilets, bathrooms, and kitchen area, depth m2 823

as per the Drawings No RB-A905,RB-A803

09 75 13 Stone Wall Facing

Page 786: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3 Stone cladding for parapet walls at ground floor, width > 300mm, fixed over cement m2 497

sand render as per the Drawing no RB-A901

09 91 00 - Painting

Wall -Painting

4 Painting for plastered block walls, m2 8347

5 Painting for walls in staircases, m2 325

Ceiling -Painting

6 Painting for ceiling, m2 1390

7 Painting for staircase ceiling, m2 108

8 Painting for gypsum board Ceiling m2 4210

Total for FINISHES

CARRIED TO SUMMARY

10 00 00 SPECIALTIES

10 28 00 –Toilet, Bath and Laundry Accessories

Supply & install Plumbing Fixtures as shown in Drawing nr RB-A902, RB-A903 and

Technical Specification including all accessories, fittings , flexible connections etc.

1 Paper towel dispenser (PTD) nr 57

2 Soap dispenser (SD) nr 49

3 Towel ring nr 64

Page 787: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

4 Robe hook nr 64

5 Towel bar nr 64

10 44 13.13 Portable Fire Extinguishers

All items hereunder to be described with kind, quality, size, method of fixing , etc. as per

the Drawings and Specification).

6 Supply & install Portable Fire Extinguishers nr 30

7 Supply & install fire blanket nr 5

10 51 00 - Lockers

All items hereunder to be completed by specialist including but not limited to design,

supply, construction, completion, guarantee and maintenance through defect liability

period, specified codes of practice, etc. as per the Drawings and Specification).

8 Supply and fit factory made lockers 800mm high, 250mm wide 500mm depth with all nr 69

necessary accessories and manufacturers guarantees fully compliance with the project

requirement, Drawings and specification.

SPECIALTIES (Cont'd)

10 51 53 Locker Room Benches

All items hereunder to be completed by specialist including but not limited to design,

supply, construction, completion, guarantee and maintenance through defect liability

period, specified codes of practice, etc. as per the Drawings and Specification).

1 Supply and fix locker room benches (350+4130+1350) mm length 300mm wide 500mm nr 2

high

2 Supply and fix locker room benches 2500 mm length 450mm wide 500mm high nr 2

3 Supply and fix locker room benches 1750 mm length 300mm wide 500mm high nr 1

4 Supply and fix locker room benches 1300 mm length 450mm wide 500mm high nr 1

Page 788: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

10 00 00 Specialties

Additional Items

5 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

5.01 Grab Bar, 900mm Long nr 10

5.02 Grab Bar, 600mm Long nr 4

5.03 Shower Seat nr 2

5.04 Towel Pin nr 22

Total for SPECIALTIES

CARRIED TO SUMMARY

11 00 00 EQUIPMENT

All items hereunder to be described with information such as appropriate to the

procurement , design, supply, execution, type, kind, quality, size, method of fixing ,

specified codes of practice, etc. as per the Drawings and Specification).

11 30 00 Residential Equipment

1 Refrigerator/freezer nr N/A

2 Exhaust hoods nr N/A

3 Cooker nr N/A

4 Washing Machine nr N/A

11 00 00 Equipment

Additional Items

5 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Page 789: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for EQUIPMENT

CARRIED TO SUMMARY

12 00 00 FURNISHING

All items hereunder to be described with information such as appropriate to the

procurement , design, supply, execution, type, kind, quality, size, method of fixing ,

specified codes of practice, etc. as per the Drawings and Specification).

12 00 00 Furnishing

Additional Items

1 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Total for FURNISHING

CARRIED TO SUMMARY

13 00 00 SPECIAL CONSTRUCTION

All items hereunder to be completed by specialist including but not limited to design,

supply, construction, completion, guarantee and maintenance through defect liability

period, specified codes of practice, etc. as per the Drawings and Specification).

The Contractor is to engage a reputable Specialist Consultant to design the facilities

noted below. The Consultant is to provide collateral warranties to GOSI for the provision

of such services. The Contractor is to construct these items, including, but not limited to

excavation and disposal. concrete works including water stops, masonry, thermal and

moisture protection, finishes, equipment, plumbing including pump and filtering

mechanisms, heating, electrical and utilities. The Contractor is to also include for any

ancillary buildings associated with these items and is to include such spare parts as to

ensure quiet and unfettered enjoyment of these facilities.

13 24 00 Special Activity Rooms - Jacuzzi

1 The Contractor is to list here and price any items shown on the Drawings, mentioned in Item 1

Page 790: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

13 24 16 Saunas

2 The Contractor is to list here and price any items shown on the Drawings, mentioned in Item 1

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

SPECIAL CONSTRUCTION (Cont'd)

13 28 00 Athletic and Recreational Special Construction

1 Glass backed squash courts, 4 nr, (approximate size of each court 9700mm length x Item 1

6400mm width ) at ground floor including 4 nr of 12mm thick toughened safety glass

backs 6400mm length 3950mm high with opening (800mm x 2200mm) for and including

door type D14, timber sprung flooring, squash court plaster and paint to walls,

suspended ceiling, wall markings, floor markings, dead ball area in matal to front wall

etc. all in full compliance with the project requirement, Drawings and specification.

2 Climbing wall including hand/foot holes/projections, anchoring points, high platform m2 117

with all necessary accessories in full compliance with the project requirement, Drawings

and specification.

3 Supply and fix flooring type P2 absorption as per EN14904, at ground floor gymnasium, m2 1115

indoor court, aerobics and yoga area in full compliance with the project requirement,

Drawings and specification.

4 Floor marking for the following sports; vollyball, basketball, indoor soccer, badminton Item 1

5 Supply and fix ceiling for Aerobics and Yoga are, fully compliance with the project m2 277

requirement, Drawings and specification.

6 Wall finish for Aerobics and Yoga area, in full compliance with the project requirement, m2 332

Drawings and specification.

Equipment

7 Moveable vollyball nets nr 1

8 Set of 2 moveable basketball hoops including stands and backboards set 1

9 Set of 2 indoor soccer nets set 1

Page 791: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

SPECIAL CONSTRUCTION (Cont'd)

1 Moveable badminton net nr 1

13 00 00 SPECIAL CONSTRUCTION

Additional Items

2 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Total for SPECIAL CONSTRUCTION

CARRIED TO SUMMARY

14 00 00 - CONVEYING EQUIPMENT

14 10 10 - PASSENGER ELEVATORS

Contractor Designed Elevators

Supply and install 6 person passenger machine room less lift to serve three floors; refer

Specification for performance capacity, weight load, speed of travel, call system etc; car

to include floor finish to be as per entrance hallway, mirrored and hardwood ceiling with

recessed and emergency lighting, mirrored and hardwood wall finish, chromium plated

handrails, floor indicator, floor push buttons (including braille floor indicators),

emergency call button/alarm, emergency intercom; each floor to have call button and

floor indicator all as manufacturers recommendations

Page 792: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1 Elevator nr 1

Total for CONVEYING EQUIPMENT

CARRIED TO SUMMARY

21 00 00 FIRE SUPPRESSION

All Fire suppression works herein shall be completed full incompliance with the Drawings

nr SA-M011, SA-M012, SA-F201, SA-F202, SA-F203, SA-F204 and Specification

21 12 00 Fire Suppression Standpipes

Supply & Installtion testing and commissioning of steel pipes (painted). All fire fighting

pipes to be completed including but not limited to accessories,fittings,couplings

according to NFPA code/ local civil defence code. Including all kind of supports and

hangers all in accordance to the specificaJons and drawings.

1 Ditto, 65 mm diameter m 92

2 Ditto, 100 mm diameter m 16

3 Ditto, 150 mm diameter m 177

Drain Pipe

4 Ditto, 50 mm diameter m 11

21 11 19 Fire-Department Connection

5 Fire Connection Departement including Non- return Valve, 150 mm dia. nr 5

6 Fire Connection Departement including Non- return Valve, 100 mm dia. nr 1

21 12 13 Fire-Suppression Hoses and Nozzles

Fire hose reeel cabinet C/W 2-1/2" pressure restricted type landing valve 2-1/2"

synthetic hose, 1" automatic swinging hose reel, and multipurpose dry powder

extinguisher.The rate also shall be include all set of valves (landing , gate , angle,PRV etc)

Page 793: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

, Pressure gauges.

7 Surface/wall Double Fire Hose Reel Cabinet. nr 12

21 12 23 Fire-Suppression Hose Valves

Supply and installation valves complete and all necessary accessories, all in accordance

with the specifications and drawings.

8 Floor control valve assemply (FCVA) 75 mm .(Prv -OS&Y-gate) set 2

FIRE SUPPRESSION (Cont'd)

1 Floor control valve assemply (FCVA) 100 mm .(Prv -OS&Y-gate) Set 1

2 Alarm Check valve, 150mm diameter. nr 1

3 Gate Valve , 100mm diameter nr 1

4 Gate Valve , 150mm diameter nr 2

Automatic Air Vent

Supply and Installation of automatic air vent, all in accordance with the specifications

and drawings.

5 100 mm diameter. nr 2

21 13 00 Fire Suppression Sprinkler System

All Fire suppression works herein shall be completed full incompliance with the Drawings

nr SA-M011, SA-M012, SA-F201, SA-F202, SA-F203, SA-F204 and Specification.

21 13 13 Wet-Pipe Sprinkler System

Supply & Installtion testing and commissioning of steel pipes (painted). All fire fighting

pipes to be completed including but not limited to accessories,fittings,couplings

according to NFPA code/ local civil defence code. Including all kind of supports and

hangers all in accordance to the specificaJons and drawings.

6 Pipe, 25 mm diameter m 278

Page 794: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

7 Ditto, 32 mm diameter m 45

8 Ditto, 40 mm diameter m 58

9 Ditto, 50 mm diameter m 20

10 Ditto, 65 mm diameter m 81

11 Ditto, 75 mm diameter m 49

12 Ditto, 100 mm diameter m 21

FIRE SUPPRESSION (Cont'd)

1 Ditto, 150 mm diameter m 43

Sprinkler System

Supply and Installation of Sprinkler System, all in accordance with the specifications and

drawings.

2 Sprinkler head Pendent nr 106

21 22 00 Clean-Agent Fire -Extinguishing Systems

All Fire suppression works herein shall be completed full incompliance with the Drawings

nr RB-M011, RB-M012, RB-F201, RB-F202, RB-F203, RB-F204 and Specification.

21 22 13 Clean-Agent Fire -Extinguishing Piping

Supply & Installtion testing and commissioning of steel pipes (painted). All fire fighting

pipes to be completed including but not limited to accessories,fittings,couplings

according to NFPA code/ local civil defence code. Including all kind of supports and

hangers all in accordance to the specificaJons and drawings.

3 Ditto, 40 mm diameter m included in item 5 below

4 Ditto, 50 mm diameter m included in item 5 below

21 22 16 Clean-Agent Fire -Extinguishing Equipment

Supply & Installtion testing and commissioning of Clean - Agent system including

Page 795: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Cylinder , sprinkler . not limited to accessories,fittings,defence code. Including all kind

of supports and hangers all in accordance to the specifications and drawings.

5 Clean-Agent Cylinder (Novec 1230) with Sprinkler Capacity 100 Kg Set 1

21 24 00 Dry-Chemical Fire-Extinguishing Systems

6 Supply and installation of complete Automatic dry powder extinguisher with all nr 5

necessary accessories, all in accordance with the specifications and drawings.

FIRE SUPPRESSION (Cont'd)

GENERAL

TESTING, ADJUSTING, AND BALANCING OF MEP SYSTEMS

1 Allow for Starting up, pressure testing, complete testing and commissioning for all Fire Item 1

fighting system, including all necessary preparations and attendance for authority

approvals.

2 Allow for BMS system to interface with Fire fighting system. Item 1

2 Allow for drawing, manuals, approvals & instruction books. Item 1

3 Allow for protective and decorative painting Item 1

4 Allow for liaison and coordination with local authorities. Item 1

5 The contractor to list here and price any items shown in the drawings, mentioned in the

specifications or required for the satisfactory completion of this section as per the

relevant authority regulations, but not mentioned here. Any such item not listed is

deemed to be included.

21 00 00 Fire Suppression

Additional Items

6 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Page 796: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for FIRE SUPPRESSION

CARRIED TO SUMMARY

22 00 00 - PLUMBING

All items hereunder to be described specified code of practice and regulations, kind,

quality, size, method of fixing , finishes or surface treatments, etc. as per the Drawings

and Specification).

22 05 23 General-Duty Valves for Plumbing Piping

Valves

Valves are classified according to type . Material and/or size . Rates include furnishing

and installing of valves, testing at manufacturer's premises and on site; diameters of

valves and water meter according to pipe diameter which will be connected with it; as

per Drawings and Specfication.

Gate Valve

1 25 mm diam. nr 3

2 32 mm diam. nr 4

4 50 mm diam. nr 6

5 63 mm diam. nr 8

6 75 mm diam. nr 23

6 90 mm diam. nr 6

8 110 mm diam. nr 3

Angle Valve

9 20 mm diam. nr 82

Page 797: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Globe Valve

10 25 mm diam. nr 1

11 32 mm diam. nr 3

12 50 mm diam. nr 5

13 63 mm diam. nr 4

14 75 mm diam. nr 5

15 90 mm diam. nr 1

Pressure Reducing Valve

16 63 mm diam. nr 1

17 75 mm diam. nr 1

18 90 mm diam. nr 1

22 11 16 Domestic Water Piping

Domestic water piping is classified by material and diameter. Rates include furnishing

and installing of pipes, fittings, accessories, fixing supports, joints, sleeves, special parts,

connections, hanger supports. Rates to include all works and materials necessary for

complete installation for piping system as per the Drawings and Specification.

Water Supply System

1-Cold Water Supply

1 110 mm diameter. m 8

2 90 mm diameter. m 88

Page 798: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3 75 mm diameter. m 119

4 63 mm diameter. m 68

5 50 mm diameter. m 24

6 40 mm diameter. m 148

7 32 mm diameter. m 11

8 25 mm diameter. m 33

9 20 mm diameter. m 318

2-Hot Water Supply

10 20 mm diameter. m 292

3 - Accessories

11 Hose Bibb 20mm . nr 6

12 Water Meter 75 mm. nr 3

13 Water Meter 110 mm. nr 1

14 Water Hammer Arrestor nr 17

15 Automatic Air Vent. nr 6

16 Pressure Gauge . nr 6

17 Strainer 63 mm. nr 1

18 Strainer 75 mm. nr 1

19 Strainer 90 mm. nr 1

22 11 23 Domestic Water Pumps

Supply and install Domestic Water Booster pump as specified and according to drawing

Pump shall be complete with base, ,all sets of valves( gate , non return...) ,strainer,

suction diffuser control ,measuring devices control , all electric works (compenents ,

wiring , etc .) and all accessories. Electrical power supply 22/1/60.

20 Domestic water Booster Pump Set (1 Duty +1 Stand by) , 8.08 L/s Set 1

Page 799: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

21 Domestic water Booster Pump Set (1 Duty +1 Stand by) , 4.24 L/s . Set 2

22 Domestic water Booster Pump Set (1 Duty +1 Stand by) , 3.22 L/s . Set 1

23 Pressure Tank nr 4

22 13 16 Sanitary Waste and Vent Piping

Sanitary Pipe Works

Sanitary pipe works is classified by material and diameter. Rates include furnishing and

installing of pipes, fittings, accessories, fixing supprt, joints, sleeves , special parts,

connections, hanger supports. Rates for pipework below ground also include

excavation, backfilling , civil work, trenches and any other accessories or fittings

necessary for complete installation of the piping system.Testing of pipes at the

manufacturer's premises is included.All as per the Drawings and Specfication.

Pipes and fitting above ground

Waste Pipe

1 50 mm diameter. m 46

2 75 mm diameter. m 88

3 110 mm diameter. m 79

Soil Pipe

4 110 mm diameter. m 58

Pipes and fitting below ground

Waste pipe

5 75 mm diameter. m 5

6 110 mm diameter. m 63

Soil Pipe

7 110 mm diameter. m 64

Vent Pipe Works

Vent pipes are classified by material and diameter. Rates include furnishing and installing

of pipes, fittings, accessories, fixing supprt, joints, sleeves, special parts, connections,

Page 800: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

hanger supports. Rates include furnishing and installing of pipes, fittings, accessories,

fixing supprt, joints, sleeves , special parts, connections, hanger supports. Rates for

pipework below ground also include excavation, backfilling , civil work, trenches and any

other accessories or fittings necessary for complete installation of the piping

system.Testing of pipes at the manufacturer's premises is included.All as per the

Drawings and Specfication.

Pipes and fittings above ground

8 75 mm diameter. m 362

Pipes and fitting below ground

9 75 mm diameter. m 14

22 13 19.13 Sanitary Drains

Sanitary drains (to include rainwater pipework and condensate drain pipework) are

classified by material and diameter. Rates include furnishing and installing of pipes,

fittings, accessories, fixing supports, joints, sleeves, special parts, connections, hanger

supports. Rates also include testing of pipes at the manufacturer's premises. All as per

the Drawings and specfication.

Rain water Pipe

1 75 mm diameter. m 145

Condensate Drain Pipe Works

2 20 mm diameter. m 70

3 25 mm diameter. m 75

4 32 mm diameter. m 52

Page 801: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

5 40 mm diameter. m 12

6 50 mm diameter. m 13

22 33 00 Electric Domestic Water Heaters

Electric domestic water heaters are classified according to capacity. Rates include

furnishing of heater complete with safety valves, air vent, pressure and tempearture

relief gauges, drain valves, all valves set (angle, gate, non return, etc .), thermostat,

heating element, contactors, switch, support, bolts, nuts, connection of pipes, testing on

site, commissioning and putting into service.

7 EWH-RB-01 with (30 litres / 1200 W) capacity. nr 19

8 EWH-RB-02 with (100 litres / 1500 W) capacity. nr 4

9 EWH-RB-03 with (150 litres / 1500 W) capacity. nr 8

10 EWH-RB-04 with (50 litres / 1200 W) capacity. nr 1

22 40 00 Plumbing Fixtures

All items described hereunder to be of kind, quality, size, nature of base, method of

fixing, complete with accessories etc. as per the Drawings nr V1-903 and Specification

11 Floor Drain (FD) nr 79

12 Flexible Shower Hose (Sprayer , valves , etc….) nr 39

Page 802: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1 Wall mounted (Flush Valve) western water closet set (fitting , push button, flush nr 34

valve)

2 Floor mounted (Flush Valve) western water closet set (fitting, push button, flush nr 5

valve)

3 Floor clean out nr 24

4 Roof drain nr 5

5 Scupper drain nr 14

6 Vent cap nr 6

7 Jacuzzi including (taps, plug, accessories and fitting). nr 2

As per the drawing it is integrated

8 Wash basin (WB) nr 40

As per Q&A no. 358 clothes washing not in contract, only connection

9 Washing machine connections (washing machine measured elsewhere) nr 0

As per Q&A no. 360 shower channel to be used

10 Shower (SHO) including shower channel, mixer tap, fitting, spray and adjustable bar nr 22

setting

As per Q&A-383, the sink bowl is

11 Kitchen sink nr 1

12 Taps for wash basin including fittings , plugs, valves, connections and waste. nr 40

13 Mixer tap for kitchen sink including fitting, plugs, chrome plated pipes, valves and nr 1

waste

22 00 00 - Plumbing

Additional Items

10 Inspection chamber as per Drawings and Specification; connected directly to nr 6

sewer network.

11 Grease Interceptor as per Drawings and Specification nr 1

12 Pressure Breaking Manhole m 2

Page 803: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1 Clean out (CO) nr 2

2 Roof Water tank as per Specification; rate shall be include supplying and nr 4

installing, all fittings, accessories, valves, pipework, vents etc. as per the Drawings

and Specification

3 Gully Trap nr 6

Additional Items

4 Marking the position of holes, mortices and chases in the structure Item 1

5 Identification; plates, discs, labels, tapes, bands, arrows, symbols, letters, numbers and Item 1

charts; as stated on drawings and in Specification

6 Testing and commissioning of entire installation Item 1

7 Preparation of as-built drawings Item 1

8 Preparation of operation and maintenance manuals Item 1

9 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Total for PLUMBING

CARRIED TO SUMMARY

23 00 00 - HEATING, VENTILATING, AND AIR CONDITIONING (HVAC)

All HVAC works shall be completed as per the Drawings nr RB-M001, RB-M002, RBM003,

RB-M004, RB-M005, RB-M006, RB-M007, RB-M008, RB-M201, RB-M201A, RBM201B,

RB-M201C, RB-M202, RB-M202A, RB-M202B, RB-M202C, RB-M203, RB-M203A,

RB-M203B and Specification.

23 07 13 Duct Insulations

Page 804: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

All items described hereunder to be of type, kind, quality, thickness, method of fixing,

specified codes of practice, etc. as per the Drawings and Specification

1 Supply and fix ductwork insulations outdoor for (supply, return, fresh air, exhaust ,etc.); m2 1375

air duct to include fixing and accessories as per the Drawings and Specification

23 31 00 HVAC Ducts and Casings

All items described hereunder to be of type, kind, quality, size, method of fixing,

specified codes of practice, method of fixing/supports,necessary accessories etc. as per

the Drawings and Specification

Notwithstanding the provisions of the Standard Method of Measurement, internal Note

ductwork is to include insulation to the ductwork. No claim for additional cost due to

lack or want of knowledge will be entertained

Supply and fix insulated indoor galvanized steel sheet metal duct work for all HVAC work

as specified and as indicating on drawings, complete with bends, supports, connections,

fittings, splices and all accessories to complete the work.

2 Gauge 26 Kg 1402

As per Q&A no, 528, item no, 3 read as 24 Guage

3 Gauge 24 Kg 8146

As per Q&A no, 528, item no, 4 read as 22 Guage

4 Gauge 22 Kg 13953

HEATING, VENTILATING, AND AIR CONDITIONING (Cont'd)

23 33 13.13 Volume-Control Dampers

All items described hereunder to be of type, kind, quality, size, method of fixing,

specified codes of practice, etc. as per the Drawings and Specification

Volume Dampers

1 Volume Damper ; 150x150 mm. nr 11

Page 805: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2 Volume Damper ; 200x150 mm. nr 1

3 Volume Damper ; 200x200 mm. nr 3

4 Volume Damper ; 250x150 mm. nr 1

5 Volume Damper ; 250x200 mm. nr 1

6 Volume Damper ; 300x150 mm. nr 2

7 Volume Damper ; 300x250 mm. nr 1

8 Volume Damper ; 300x300mm. nr 1

9 Volume Damper ; 400x300 mm. nr 4

10 Volume Damper ; 500x200 mm. nr 1

11 Volume Damper ; 500x300 mm. nr 2

12 Volume Damper ; 500x350 mm. nr 2

13 Volume Damper ; 550x350 mm. nr 1

14 Volume Damper ; 600x300 mm. nr 9

15 Volume Damper ; 6000x350 mm. nr 2

16 Volume Damper ; 800x200 mm. nr 1

17 Volume Damper ; 850x600 mm. nr 1

18 Volume Damper ; 900x400 mm. nr 1

HEATING, VENTILATING, AND AIR CONDITIONING (Cont'd)

1 Volume Damper ; 1000x300 mm. nr 2

Page 806: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2 Volume Damper ; 1000x400 mm. nr 1

3 Volume Damper ; 1050x400 mm. nr 1

4 Volume Damper ; 1100x500 mm. nr 1

5 Volume Damper ; 125 mm dia. circular damper. nr 2

6 Volume Damper ; 150 mm dia. circular damper. nr 7

7 Volume Damper ; 200 mm dia. circular damper. nr 47

8 Volume Damper ; 250 mm dia. circular damper. nr 198

9 Volume Damper ; 275 mm dia. circular damper. nr 2

10 Volume Damper ; 300 mm dia. circular damper. nr 10

11 Volume Damper ; 600 mm dia. circular damper. nr 2

12 Volume Damper ; 700 mm dia. circular damper. nr 14

Splitter Dampers

13 Splitter Damper ; 400 x 250mm. nr 1

14 Splitter Damper ; 500 x 300mm. nr 1

15 Splitter Damper ; 600 x 250mm. nr 1

HEATING, VENTILATING, AND AIR CONDITIONING (Cont'd)

23 33 46 Flexible Ducts

All items described hereunder to be of type, kind, quality, size, method of fixing,

specified codes of practice, etc. as per the Drawings and Specification

Page 807: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1 Supply and install flexible duct with insulation; size 125 mm dia. m 2

2 Supply and install flexible duct with insulation; size 150 mm dia. m 6

3 Supply and install flexible duct with insulation; size 200 mm dia. m 38

4 Supply and install flexible duct with insulation; size 250 mm dia. m 155

5 Supply and install flexible duct with insulation; size 275 mm dia. m 2

6 Supply and install flexible duct with insulation; size 300 mm dia. m 8

23 34 00 HVAC Fans

All items described hereunder to be of capacity, design, supply, execution, type, kind,

quality, size, method of fixing , specified codes of practice, etc. as per the Drawings and

Specification

Supply and install exhaust fan as specified and as indicated in drawing. Fan consists of

casing, fan, motor, control, filter, sand trap louver, all electrical works (compenents,

wiring, switches etc.) and all accessories. Electrical power supply 220/1/60.

Ceiling Mounted Inline Cabinet type

7 Exhaust Fan (TEF-01), 75 Pa, with total air flow 105 L/S nr 1

Roof Mounted Centrifugal Inline Cabinet type

8 Exhaust Fan (TEF-04), 300 Pa with total air flow 1840 L/S . (1 Working +1 Stand by) Set 1

9 Exhaust Fan (GEF-01), 200 Pa with total air flow 870 L/S nr 1

10 Exhaust Fan (GEF-06), 200 Pa with total air flow 590 L/S nr 1

HEATING, VENTILATING, AND AIR CONDITIONING (Cont'd)

1 Exhaust Fan (GEF-07), 200 Pa with total air flow 1275 L/S nr 1

2 Exhaust Fan (GEF-08), 200 Pa with total air flow 205 L/S nr 1

Page 808: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3 Exhaust Fan (GEF-09), 200 Pa with total air flow 735 L/S nr 1

4 Exhaust Fan (GEF-10), 200 Pa with total air flow 485 L/S nr 1

Roof Mounted Centrifugal up blastType

5 Exhaust Fan (TEF-02)/(TEF-03), 100 Pa, with total air flow 245 L/S . nr 2

6 Exhaust Fan (TEF-05), 350 Pa, with total air flow 75 L/S . nr 1

7 Exhaust Fan (GEF-02 to GEF 05), 100 Pa, with total air flow 95 L/S . nr 4

8 Exhaust Fan (GEF-11, GEF 12), 100 Pa, with total air flow 555 L/S . nr 2

Roof Mounted Centrifugal up blastType

9 Exhaust Fan (SEF-01), 50 Pa, with total air flow 220 L/S . nr 1

10 Exhaust Fan (SEF-02), 50 Pa, with total air flow 355 L/S . nr 1

11 Exhaust Fan (FAF-01), 100 Pa, with total air flow 230 L/S . nr 1

23 36 16 Variable-Air-Volume Units

All items described hereunder to be of capacity, design, supply, execution, type, kind,

quality, size, method of fixing , specified codes of practice, etc. as per the Drawings and

Specification

Supply and install Variable-Air-Volume Units as specified and as indicated in drawing.

Units consists of casing, fan, motor, control, filter, sand trap louver, all electrical works

(compenents, wiring, switches etc.) and all accessories. Electrical power supply 220/1/60.

12 Variable air volume units (VAV-GF-01), 50Pa,design air flow 680 L/s, Heating capacity nr 1

1.9kW

Page 809: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

HEATING, VENTILATING, AND AIR CONDITIONING (Cont'd)

1 Variable air volume units (VAV-GF-02), 50Pa,design air flow 505 L/s, Heating capacity nr 1

1.1kW

2 Variable air volume units (VAV-GF-03)/(VAV-GF-04), 50Pa,design air flow 415L/s, Heating nr 2

capacity 0.5kW

3 Variable air volume units (VAV-GF-05), 50Pa,design air flow 100 L/s, Heating capacity nr 1

0.5kW

4 Variable air volume units (VAV-GF-06), 50Pa,design air flow 835 L/s, Heating capacity nr 1

1.2kW

5 Variable air volume units (VAV-GF-07)/(VAV-GF-08), 50Pa,design air flow 225 L/s, nr 2

Heating capacity 0.4kW

6 Variable air volume units (VAV-GF-09), 50Pa,design air flow 260 L/s, Heating capacity nr 1

1kW

7 Variable air volume units (VAV-GF-10), 50Pa,design air flow 340 L/s, Heating capacity nr 1

0.9kW

8 Variable air volume units (VAV-GF-11), 50Pa,design air flow 345 L/s, Heating capacity nr 1

1.4kW

9 Variable air volume units (VAV-GF-12), 50Pa,design air flow 50L/s nr 1

10 Variable air volume units (VAV-GF-13 to VAV-GF-16), 50Pa,design air flow 50L/s nr 4

11 Variable air volume units (VAV-GF-17), 50Pa,design air flow 170 L/s, Heating capacity nr 1

0.1kW

Page 810: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

12 Variable air volume units (VAV-GF-18), 50Pa,design air flow 345 L/s, Heating capacity nr 1

0.9kW

13 Variable air volume units (VAV-GF-19), 50Pa,design air flow 405 L/s, Heating capacity nr 1

1.4kW

14 Variable air volume units (VAV-GF-20), 50Pa,design air flow 1325 L/s, Heating capacity nr 1

4.8kW

15 Variable air volume units (VAV-FF-01), 50Pa,design air flow 1020 L/s, Heating capacity nr 1

1.8kW

16 Variable air volume units (VAV-FF-02), 50Pa,design air flow 165 L/s, Heating capacity nr 1

0.2kW

HEATING, VENTILATING, AND AIR CONDITIONING (Cont'd)

1 Variable air volume units (VAV-FF-03), 50Pa,design air flow 320 L/s, Heating capacity nr 1

0.3kW

2 Variable air volume units (VAV-FF-04), 50Pa,design air flow 185 L/s, Heating capacity nr 1

0.4kW

3 Variable air volume units (VAV-FF-05), 50Pa,design air flow 135 L/s, Heating capacity nr 1

0.3kW

4 Variable air volume units (VAV-FF-06), 50Pa,design air flow 135 L/s, Heating capacity nr 1

0.4kW

5 Variable air volume units (VAV-FF-07), 50Pa,design air flow 230L/s, Heating capacity nr 1

0.6kW

6 Variable air volume units (VAV-FF-08), 50Pa,design air flow 215L/s, Heating capacity nr 1

0.6kW

7 Variable air volume units (VAV-FF-09A), 50Pa,design air flow 770L/s, Heating capacity nr 1

2.2kW

8 Variable air volume units (VAV-FF-09B), 50Pa,design air flow 560L/s, Heating capacity nr 1

2kW

9 Variable air volume units (VAV-FF-10), 50Pa,design air flow 645L/s, Heating capacity nr 1

0.9kW

10 Variable air volume units (VAV-FF-11), 50Pa,design air flow 170L/s, Heating capacity nr 1

Page 811: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

0.4kW

11 Variable air volume units (VAV-FF-12), 50Pa,design air flow 185L/s, Heating capacity nr 1

0.3kW

12 Variable air volume units (VAV-FF-12), 50Pa,design air flow 425L/s, Heating capacity nr 1

0.8kW

23 37 00 Air outlets and Inlets

All items described hereunder to be of type, kind, quality, size, method of fixing,

specified codes of practice, etc. as per the Drawings and Specification

Supply and install painted supply linear bar air register with complete accessories as per

the Drawings and Specification

13 1000mm long 3 slot Supply linear bar grille nr 154

14 1000mm long 2 slot Supply linear bar grille nr 47

HEATING, VENTILATING, AND AIR CONDITIONING (Cont'd)

Supply and install painted return linear bar air grille with complete accessories as per the

Drawings and Specification.

1 1000mm long 3 slot return linear bar grille nr 164

2 1000mm long 2 slot return linear bar grille nr 34

Page 812: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Supply and install painted Jet nozzles with complete accessories as per the Drawings and

Specification.

3 Jet nozzles, 350 mm dia nr 28

4 Jet nozzles, 300 mm dia nr 24

Supply and install supply ceiling diffuser with complete accessories as per the Drawings

and Specification.

5 Supply ceiling diffuser, 300mm x 300mm nr 11

6 Supply ceiling diffuser, 375mm x 375mm nr 15

7 Supply ceiling diffuser, 450mm x 450mm nr 39

Supply and install return ceiling diffuser with complete accessories as per the Drawings

and Specification

8 Return ceiling diffuser, 300mm x 300mm nr 9

9 Return ceiling diffuser, 375mm x 375mm nr 11

10 Return ceiling diffuser, 450mm x 450mm nr 39

Exhaust air louver

11 Exhaust air louver ; (850X400)mm. nr 1

Fresh Air Sand Trap Louver

12 Fresh Air Sand Trap Louver with filter 1000mm x 200mm nr 1

HEATING, VENTILATING, AND AIR CONDITIONING (Cont'd)

Disk Valve

1 Disk Valve ; 150 mm dia . nr 63

23 82 00 Convection Heating and Cooling Units

Page 813: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

All items described hereunder to be of capacity, design, supply, execution, type, kind,

quality, size, method of fixing , specified codes of practice, etc. as per the Drawing nr RBM015

and Specification

Supply and install Package Unit (PACU)as specified and as indicated in drawing. Unit to

be complete with air cooled condensing unit , fan , pre filter ,bag filter,damper and sand

trap louver with filter , valves ,Sound attenuator,control , thermostat, all electrical

works (compenents , wiring , etc .) and all accessories. Electrical power supply 380/3/60.

2 (PACU-RF-01) , 3,434 L / s , 800 Pa ; Heating Capacity 10.8 kW . nr 1

3 (PACU-RF-02) , 3,283 L / s , 800 Pa ; Heating Capacity 9.7 kW . nr 1

4 (PACU-RF-03) , 2,117 L / s , 800 Pa ; nr 1

5 (PACU-RF-04), (PACU-RF-05) , 2,764 L / s , 800 Pa ; Heating Capacity 16.2 kW . nr 2

6 (PACU-RF-06) , 1,340 L / s , 800 Pa ; Heating Capacity 4.3 kW . nr 1

7 (PACU-RF-07) , 6,017 L / s , 800 Pa ; nr 1

8 (PACU-RF-08) , 3,130 L / s , 800 Pa ; Heating Capacity 11.1 kW . nr 1

9 (PACU-RF-09) , 2,626 L / s , 800 Pa ; Heating Capacity 14.5 kW . nr 1

10 (PACU-RF-10) , 1,304 L / s , 800 Pa ; Heating Capacity 10.0 kW . nr 1

11 (PACU-RF-11), (PACU-RF-12), 4,199 L / s , 800 Pa ; Heating Capacity 13.5 kW . nr 2

12 (PACU-RF-13) , 3,979 L / s , 800 Pa ; nr 1

HEATING, VENTILATING, AND AIR CONDITIONING (Cont'd)

Supply and install concealed fan coil unit as specified and as indicated in drawing. Unit to

be complete with air cooled condensing unit, fan, filter, valves, controls, thermostat, all

electrical works (compenents, wiring, switches etc.) and all accessories. Electrical power

supply 220/1/60.

1 (FCU-01/ACCU-01), 185 L / s ; Sensible Capacity 2 kW . nr 1

Page 814: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2 (FCU-02/ACCU-02), 150 L / s ; Sensible Capacity 1.3 kW . nr 1

3 (FCU-03/ACCU-03), 280 L / s ; Sensible Capacity 3 kW . nr 1

4 (FCU-04/ACCU-04), 435 L / s, 50 Pa ; Sensible Capacity 5.6 kW . nr 2

5 (FCU-05/ACCU-05), 525 L / s, 50 Pa ; Sensible Capacity 7 kW nr 1

6 (FCU-06/ACCU-06) , 725 L / s, 50 Pa ; Sensible Capacity 9.6 kW . nr 1

7 (FCU-07/ACCU-07) , 625 L / s, 50 Pa ; Sensible Capacity 7 kW . nr 1

8 (FCU-08/ACCU-08) , 235 L / s, 50 Pa ; Sensible Capacity 3.1 kW . nr 1

9 (FCU-09/ACCU-09) , 170 L / s, 50 Pa ; Sensible Capacity 2.3 kW . nr 1

10 (FCU-10/ACCU-10) , 125 L / s ; Sensible Capacity 1.1 kW . nr 1

11 (FCU-11/ACCU-11) , 195 L / s ; Sensible Capacity 2.1 kW . nr 1

Supply and install concealed Dehumidifier as specified and as indicated in drawing. Unit

to be complete with, fan, filter, valves, controls, thermostat, all electrical works

(compenents, wiring, switches etc.) and all accessories. Electrical power supply 220/1/60.

12 (DH-RF-01), 835 L/S, 100 Pa ; Heating Capacity 35 LW nr 2

23 05 93 Testing, Adjusting and Balancing for HVAC

All items described hereunder to be as required by type of installation, preparatory

operations, stages of test (nr), required attendance, applicable codes etc. as per the

Drawings and Specification).

1 Air balancing of the ducting network Item 1

2 Testing, balancing and commissioning of all the equipment Item 1

Page 815: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

23 00 00 - Heating, Ventilating, and Air Conditioning (HVAC)

Additional Items

1 Marking the position of holes, mortices and chases in the structure Item 1

2 Identification; plates, discs, labels, tapes, bands, arrows, symbols, letters, numbers and Item 1

charts; as stated on drawings and in Specification

3 Testing and commissioning of entire installation Item 1

4 Preparation of as-built drawings Item 1

5 Preparation of operation and maintenance manuals Item 1

6 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

6.01 Supply Air Register, 450 x 150 No. 1

6.02 Supply Air Register, 800 x 200 No. 1

6.03 Exhasut Air Grille, 150 x 100 No. 1

6.04 Circular Duct (indoor), Dia 400 LM 34

6.05 Circular Duct (indoor), Dia 500 LM 21

6.06 Circular Duct (indoor), Dia 600 LM 80

6.07 Circular Duct (outdoor), Dia 600 LM 12

6.08 Circular Duct (outdoor), Dia 700 LM 24

6.09 Circular Duct (outdoor), Dia 850 LM 36

6.10 Fire Damper, 1100 x 350 No. 1

6.11 Fire, Damper, 1000 x 400 No. 1

6.12 Fire Damper, 900 x 400 No. 1

6.13 Fire Damper, 600 x 300 No. 2

6.14 Fire Damper, 550 x 300 No. 2

6.15 Fire Damper, 500 x 200 No. 1

6.16 Fire Damper, 450 x 250 No. 1

6.17 Fire Damper, 300 x 200 No. 1

6.18 Fire Damper, 200 x 150 No. 1

6.19 Volume Damper, 1200 x 400 No. 1

6.20 Volume Damper, 1100 x 350 No. 1

6.21 Volume Damper, 900 x 300 No. 1

6.22 Volume Damper, 800 x 700 No. 3

Page 816: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

6.23 Volume Damper, 750 x 300 No. 1

6.24 Volume Damper, 600 x 400 No. 2

6.25 Volume Damper, 600 x 350 No. 2

6.26 Volume Damper, 550 x 200 No. 1

6.27 Volume Damper, 500 x 150 No. 2

6.28 Volume Damper, 400 x 200 No. 1

6.29 Volume Damper, 350 x 300 No. 1

6.30 Volume Damper, 350 x 200 No. 1

6.31 Volume Damper, 300 x 200 No. 1

6.32 Volume Damper, Dia 750 mm No. 8

6.33 Motorized Volume Damper, Dia 600 mm No. 2

6.34 Refrigerant piping, 20 mm diameter with max liquid line 10 mm. m 53

6.35 Building Management System Item 1

Total for HVAC

CARRIED TO SUMMARY

26 00 00 - ELECTRICAL

All works hereunder shall be completed as per the Drawings and Specification.

26 05 19 Low Voltage Electrical Power Conductors and cables

All items hereunder to be of type, kind, number of cores, armoring and sheathings,

method of fixing , specified codes of practice, etc. as per the Drawings and Specification).

Notwithstanding the Provisions of the method of measurement, cables have been

itemised and referenced to the circuit. The contractor is to make due reference to

drawings nrs E000, E001, E002, E003, EL201(A, B and C), EL202, EP201 (A, B and C),

EP202(A, B and C), MP201(A, B and C), MP202(A, B and C) MP203(A and B), CR301(A, B

and C), CR302(A, B and C), CR303(A and B), LP401(A, B and C), LP403(A, B and C), PS301,

PS302, PS303, PS304, MD401, MD402, MD403, MD404 for full details and is to allow for

all cabling, junctions, flexible connections, feeder units etc. required to complete the

installation in accordance with the drawings and Specification. No claim for want or lack

of knowledge will be entertained

1 Lighting circuits Item 1

2 Power circuits Item 1

3 Fire alarm circuits Item 1

4 Water heater circuits Item 1

Page 817: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

4 Fan circuits Item 1

5 Outdoor lighting circuits Item 1

6 HVAC control circuits Item 1

7 Emergency lighting circuits Item 1

8 Lift power circuits Item 1

9 Lightning protection Item 1

ELECTRICAL (Cont'd)

26 05 26 Grounding and Bonding for Electrical Systems

All items hereunder to be described with information such as type, kind, number of

cores, armoring and sheathings, method of fixing , specified codes of practice, etc. as per

the Drawings and Specification).

1 grounding system Item 1

26 05 33.13 Conduit for Electrical Systems

All items hereunder to be described with information such as type, kind, , method of

fixing , specified codes of practice, etc. as per the Drawings and Specification).

Notwithstanding the Provisions of the method of measurement, conduits have been

itemised and referenced to the circuit. The contractor is to make due reference to

drawings nrs E000, E001, E002, E003, EL201(A, B and C), EL202, EP201 (A, B and C),

EP202(A, B and C), MP201(A, B and C), MP202(A, B and C) MP203(A and B), CR301(A, B

and C), CR302(A, B and C), CR303(A and B), LP401(A, B and C), LP403(A, B and C), PS301,

PS302, PS303, PS304, MD401, MD402, MD403, MD404 for full details and is to allow for

all conduit, junctions, flexible connections, feeder units etc. required to complete the

installation in accordance with the drawings and Specification. No claim for want or lack

of knowledge will be entertained

Page 818: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2 Lighting circuits Item 1

3 Power circuits Item 1

4 Fire alarm circuits Item 1

5 Water heater circuits Item 1

6 Fan circuits Item 1

7 Outdoor lighting circuits Item 1

8 Emergency lighting circuits Item 1

ELECTRICAL (Cont'd)

1 Lift power circuits Item 1

2 Lightning protection Item 1

26 05 36 Cable Trays for Electrical Systems

All items hereunder to be described with information such as type, kind, , method of

fixing , specified codes of practice, etc. as per the Drawings and Specification).

Notwithstanding the Provisions of the method of measurement, cable trays have been

have been itemised and referenced to the cable tray size. The contractor is to make due

reference to drawings nrs E000, E001, E002, E003, EL201(A, B and C), EL202, EP201 (A, B

and C), EP202(A, B and C), MP201(A, B and C), MP202(A, B and C) MP203(A and B),

CR301(A, B and C), CR302(A, B and C), CR303(A and B), LP401(A, B and C), LP403(A, B and

C), PS301, PS302, PS303, PS304, MD401, MD402, MD403, MD404 for full details and is to

allow for all cable trays, junctions, flexible connections, feeder units etc. required to

complete the installation in accordance with the drawings and Specification. No claim for

want or lack of knowledge will be entertained

3 Galvanized steel cable tray 200 x 100 Item 1

4 Galvanized steel cable tray 400 x 100 Item 1

Page 819: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

5 Galvanized steel cable tray with cover 200 x 100 Item 1

6 Galvanized steel cable tray with cover 100 x 100 Item 1

7 Galvanized steel cable tray with cover 200 x 100 Item 1

8 Galvanized steel cable tray with cover 400 x 100 Item 1

9 Galvanized steel cable tray with cover 600 x 100 Item 1

ELECTRICAL (Cont'd)

26 24 13 Switchboards

1 All items hereunder to be described with information such as type, kind, rated capacity,

method of fixing, cores reference to Specification, fuses, background, specified codes of

practice, etc. as per the Drawings and Specification).

26 24 16 Panel boards

All items hereunder to be described with information such as type, kind, rated capacity,

method of fixing, cores reference to Specification, fuses, codes of practice, etc. as per

the Drawings and Specification).

2 Main distribution boards Item 1

3 Sub-main distribution boards Item 1

26 27 13 Electricity Metering

4 All items hereunder to be described with information such as type, kind, rated capacity,

method of fixing, cores reference to Specification, fuses, codes of practice, etc. as per

the Drawings and Specification). Item 1

26 27 26 Wiring Devices

Notwithstanding the Provisions of the Method of Measurement, wiring devices shall

include final circuits. No claim for lack or want of knowledge shall be entertained

Page 820: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Switches & Push Buttons

All items hereunder to be described with information such as appropriate to the

procurement , type, kind, quality, size, method of fixing , specified codes of practice, etc.

as per the Drawings and Specification).

5 One way one gang switch nr 47

6 One way two gang switch nr 14

7 One way three gang switch nr 3

8 Two way one gang switch nr 12

ELECTRICAL (Cont'd)

Power Outlets

1 Industrial type single outlet with dust proof cover nr 67

2 Industrial type double outlet with dust proof cover nr 51

Page 821: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3 Non fusable disconnect switch 2 pole with indicator nr 46

4 Non fusable disconnect switch nr 31

26 33 53 Static Uninterruptible Power Supply

All items hereunder to be described with information such as appropriate to the

procurement , type, kind, quality, size, method of fixing , specified codes of practice, etc.

as per the Drawings and Specification).

5 UPS with rating of a 40KVA Item 1

Section 26 41 13

Lighting Protection for Structures

Supply, installation, testing, for lighting protection system include detailing, roofmounted

air terminals, conductors, sleeves ,grounds rod assembly, complete with

equipment, furnishing all materials, and all associated civil works relevant to fixation and

installation as specified and shown on drawings for proper installation & operation.

6 Lighting Protection System Item 1

26 50 00 Lighting

All items hereunder to be described with information such as appropriate to the

procurement , type, kind, quality, size, method of fixing , specified codes of practice, etc.

as per the Drawings and Specification).

7 Luminaire, surface mounted flourescent lamp with diffuser, 2 x 36W; type A1 nr 16

ELECTRICAL (Cont'd)

1 Luminaire, recess mounted with diffuser in frame, 4 x 18W; type B1 nr 26

2 Luminaries,recess mounted downlight, compact flourescent lamp with closed dome nr 199

reflector, 2 x 26W CFL; type D1

3 Luminaries,recess mounted downlight, compact flourescent lamp with glass cover, 1 x nr 15

Page 822: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

26W CFL; type D3

4 Luminaire,LED downlight recessed mounted, round shape; 1 x 6W, 220V, 60hz; type R2 nr 183

5 Luminaire, recess mounted down light with closed dome reflector; type S2 nr 43

6 Luminaire, wall mounted 100W CFL with globe diffuser; type W1 nr 7

7 Luminaire, trim flourescent mirror light, die cast aliminium body, 18W 12V; type W2 nr 16

8 Luminaire, up/down wall mounted; 2 x 26W CDL; type W3 nr 82

9 Luminaire, wall mountedflourescent light; 2 x 36W with diffuser; type W4 nr 23

10 Luminaire, wall mounted CDL;125W die cast aluminium; type W5 nr 10

11 Luminaire, self contained exit light with directional arrow nr 11

12 Pole street lights with HPF ballast, metal diffuser cover, one arm, 250W, 6m including nr 9

excavation and concrete to base and pot; type P3

13 Pole street lights with HPF ballast, metal diffuser cover, two arms, 250W, 6m including nr 1

excavation and concrete to base and pot; type P4

ELECTRICAL (Cont'd)

26 00 00 - Electrical

Additional Items

1 Marking the position of holes, mortices and chases in the structure Item 1

2 Identification; plates, discs, labels, tapes, bands, arrows, symbols, letters, numbers and Item 1

charts; as stated on drawings and in Specification

3 Testing and commissioning of entire installation Item 1

4 Preparation of as-built drawings Item 1

5 Preparation of operation and maintenance manuals Item 1

Page 823: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

6 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

6.01 One Switch for Water Heater With pilot Lamp Nr 31

6.02 Galvanized steel cable tray with cover 1000 x 100 m 193

6.03 Feeder cable from Main distribution board to Distribution boards (As per Q&A # 537) Item 1

6.04 M 147

6.05 Swimming Pool Distribution Panel Nr 1

Total for ELECTRICAL

CARRIED TO SUMMARY

27 00 00 COMMUNICATIONS

Telecommunication / Low Current

STRUCTURED CABLING SYSTEM

Supply, Install, Test, connect and commission inclusive of all cabling, conduits and

containment, socket outlets, all in accordance with the relevant service provider

regulations , rules, recommendation and requirements and in accordance with the

specifications and drawings.

1 Information Outlet, Flush Type 1 DATA, 1 Telephone 0.3 Meters A.F.F.L. nr 33

2 Telephone Outlet, Wall Mounted Flush Type, MTD 0.30m A.F.F.L nr 11

Power Supply from MDB-RE2 to swimming pool, jacuzzi and Fountain DB in Recreation Building (4x50mm²+25mm².)

Page 824: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3 Data Outlet, Flush Type, 0.3 Meters A.F.F.L. nr 1

4 Fiber Terminal Box nr 11

5 15U Telecom Cabinet, Wall Mounted nr 3

6 CAT 6A, UTP Cable m 480

7 Single Mode Fiber Optic Cable - 4 x 2 Core m 350

Water Metering

Supply, Install, Test, connect and commission inclusive of all cabling, conduits and

containment, socket outlets, all in accordance with the relevant service provider

regulations , rules, recommendation and requirements and in accordance with the

specifications and drawings.

8 Water Metering Reciever nr 1

9 M-bus Cable, 2 x 18AWG m 100

Fire Alarm System

Supply, install, connection, testing and commisioning of wiring and equipment for Fire

Alarm System including all necessary materials and accessories to reflect complete

system installation.

1 Addressable, smoke detector nr 60

2 Addressable, heat detector nr 2

3 Smoke detector, Beam type - Transceiver nr 5

4 Beam type - Reflector nr 5

5 Addressable, Duct Detector nr 5

6 Addressable, Manual Pull Station nr 23

7 Sounder / Fire Alarm Bell / Horn nr 24

8 Multisensor Detector nr 10

Page 825: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

9 Fault Isolator nr 10

10 Control Module nr 15

11 Control Module for Tamper Switch nr 5

12 Control Module for Flow Switch nr 5

13 Fire Alarm Control Panel nr 2

14 Power Supply Unit, 24v nr 2

15 Loop Cable, 2x1.5mm2 Fire Resistant m 1000

16 24V Cable, 2x2.5mm2 Fire Resistant m 550

Additional Items

1 Marking the position of holes, mortises and chases in the structure Item 1

2 Identification; plates, discs, labels, tapes, bands, arrows, symbols, letters, numbers and Item 1

charts; as stated on drawings and in Specification

3 Testing and commissioning of entire installation Item 1

4 Preparation of as-built drawings Item 1

5 Preparation of operation and maintenance manuals Item 1

6 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

ADDITIONAL ACTIVE COMPONENTS AS PER Q & A NO. 487, 488, 489 & 490

6.01 Fire Alarm Repeater Panel nr 2

6.02 Main Fire Alarm Panel with Workstation nr 3

6.03 CCTV Main Equipment Item 1

Page 826: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

6.04 IP-TV Main Equipment Item 1

6.05 IP-PABX Main Equipment Item 1

6.06 DATA / INTERNET AND CORE SYSTEM Item 1

6.07 42U COMMUNICATION CABINET nr 12

6.08

ACTIVE COMPONENTS (AS PER Q&A 487) DISTRIBUTION CABINET

nr 3

Total for COMMUNICATIONS

CARRIED TO SUMMARY

31 00 00 EARTHWORK

All works herein shall be completed in full compliance with the Drawings nr RB-S001,RBS002,

RB-S003,RB-S004,RB-S005,RB-S401and Specification.

31 10 00 Site Clearing

1 Site preparation, clearing site vegetation m2 7279

31 23 16 Excavation

2 Excavating top soil for preservation, average depth 150mm. m2 7279

3 Excavating pits (203 nr), maximum depth ≤ 2.00m. m3 4115

4 Excavating pits (1 nr), maximum depth 2m - 4m for swimminpool m3 1033

5 Excavating trenches for grade beams, width > 0.3m m3 439

31 23 23 .13 Backfill

Page 827: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

6 Filling to excavations, average thickness > 0.25 m, arising from excavated materials, all m3 2988

fill shall be compacted to 75% relative density for cohesion-less soils as per ASTM

D4254/ASTM D4293 or 95% maximum density as determined by ASTM D698 for

cohesive material, as per the Drawings and Specifications).

31 23 23.23 Compaction

7 Surface treatments, compacting bottom of excavation, compaction to meet 85% of m2 9555

relative density for cohesion-less soils or 95% maximum density as determined by ASTM

D1557 for cohesive materials per the Drawings and Specifications)

31 23 16.26 Rock Removal

8 Disposal of excavated material, off site as stated in the Specification. m3 3690

31 31 16 Termite Control

1 Termite control for the horizontal surface (method and type of treatment as per the m2 9555

Drawings and Specifications)

2 Termite control for vertical surface (method and type of treatment as per the Drawings m2 8156

and Specifications)

Additional Items

3 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Total for EARTHWORK

CARRIED TO SUMMARY

Page 828: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

03 00 00 Concrete

04 00 00 Masonry

05 00 00 Metal

06 00 00 Wood, Plastics and Composites

07 00 00 Thermal and Moisture Protection

08 00 00 Openings

09 00 00 Finishes

10 00 00 Specialties

11 00 00 Equipment

12 00 00 Furnishing

13 00 00 Special Construction

14 00 00 Conveying Equipment

21 00 00 Fire Suppression

22 00 00 Plumbing

23 00 00 Heating, Ventilating and Air Conditioning (HVAC)

26 00 00 Electrical

27 00 00 Communications

31 00 00 Earthwork

SUBTOTAL

2

AMOUNT FOR RECREATION BUILDING FORWARD TO SUMMARY

MULTIPLY BY 2 NR UNITS

Page 829: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Rate Amount

164.00 102,008.00

380.00 439,280.00

296.00 286,528.00

5447549.00 5,447,549.00

25.00 305,400.00

17.00 105,502.00

372.00 8,928.00

17.00 102,170.00

32.00 12,704.00

21.00 1,386.00

11.00 1,188.00

US Dollar. 6,812,643.00

Page 830: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

42.00 8,862.00

50.00 16,250.00

39.00 25,818.00

55.00 46,200.00

39.00 97,500.00

34.00 10,268.00

34.00 306.00

34.00 986.00

42.00 840.00

44.00 1,056.00

US Dollar. 208,086.00

294.00 2,646.00

113.00 1,469.00

339.00 14,577.00

Page 831: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

346.00 346.00

US Dollar. 19,038.00

4404.00 4,404.00

1108.00 2,216.00

647.00 1,294.00

738.00 1,476.00

1269.00 2,538.00

645.00 1,290.00

590.00 590.00

Page 832: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

709.00 709.00

CF 14,517.00

BF 14,517.00

5460.00 5,460.00

712.00 712.00

6172

US Dollar. 20,689.00

Page 833: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

5.00 17,065.00

5.00 11,915.00

2.00 14,084.00

CF 43,064.00

BF 43,064.00

22.00 8,580.00

22.00 4,334.00

37.00 243,349.00

3.00 19,731.00

23.00 151,271.00

43.00 107,801.00

Page 834: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

134.00 38,190.00

CF 573,256.00

BF 573,256.00

134.00 36,180.00

US Dollar. 652,500.00

Page 835: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1503.00 6,012.00

1365.00 1,365.00

2667.00 2,667.00

CF 10,044.00

BF 10,044.00

2489.00 2,489.00

1430.00 1,430.00

2243.00 8,972.00

2243.00 2,243.00

1443.00 1,443.00

Page 836: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1420.00 1,420.00

CF 17,997.00

BF 17,997.00

1891.00 3,782.00

1355.00 18,970.00

3656.00 21,936.00

795.00 3,180.00

2896.00 20,272.00

Page 837: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 68,140.00

BF 68,140.00

2670.00 64,080.00

2670.00 13,350.00

1517.00 4,551.00

4370.00 30,590.00

4192.00 8,384.00

CF 120,955.00

BF 120,955.00

Page 838: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

4192.00 16,768.00

4192.00 8,384.00

1286.00 6,430.00

1286.00 2,572.00

1286.00 9,002.00

CF 43,156.00

BF 43,156.00

1286.00 9,002.00

Page 839: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1286.00 1,286.00

889.00 49,784.00

1181.00 7,086.00

1466.00 1,466.00

CF 68,624.00

BF 68,624.00

1466.00 1,466.00

665.00 1,330.00

2105.00 2,105.00

2105.00 2,105.00

Page 840: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2031.00 4,062.00

1467.00 2,934.00

CF 14,002.00

BF 14,002.00

1286.00 1,286.00

1286.00 11,574.00

5898.00 5,898.00

1464.00 1,464.00

6585.00 13,170.00

Page 841: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

6585.00 13,170.00

7317.00 7,317.00

CF 53,879.00

BF 53,879.00

6341.00 6,341.00

10568.00 10,568.00

10216.00 10,216.00

9335.00 18,670.00

5284.00 73,976.00

1084.00 2,168.00

3150.00 3,150.00

1692.00 3,384.00

Page 842: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 128,473.00

BF 128,473.00

4862.00 4,862.00

4885.00 9,770.00

610.00 1,830.00

9511.00 9,511.00

1317.00 1,317.00

9688.00 9,688.00

2012.00 2,012.00

CF 38,990.00

BF 38,990.00

13504.00 13,504.00

7560.00 15,120.00

Page 843: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

10060.00 10,060.00

7926.00 15,852.00

9688.00 9,688.00

1586.00 3,172.00

4024.00 4,024.00

8676.00 8,676.00

CF 80,096.00

BF 80,096.00

9688.00 9,688.00

3945.00 3,945.00

3927.00 3,927.00

3756.00 3,756.00

Page 844: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3738.00 3,738.00

4654.00 9,308.00

6052.00 12,104.00

CF 46,466.00

BF 46,466.00

82.00 492.00

251.00 502.00

170.00 340.00

180.00 360.00

354.00 708.00

175.00 350.00

Page 845: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

199.00 199.00

142.00 142.00

CF 3,093.00

BF 3,093.00

4510.00 31,570.00

4158.00 29,106.00

459.00 918.00

811.00 811.00

2880.00 5,760.00

Page 846: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

68165

US Dollar. 762,080.00

22.00 161,986.00

21.00 15,372.00

CF 177,358.00

BF 177,358.00

72.00 227,664.00

51.00 9,996.00

72.00 13,968.00

32.00 3,552.00

32.00 210,464.00

100.00 68,000.00

142.00 71,426.00

Page 847: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 605,070.00

BF 605,070.00

17.00 23,545.00

19.00 570.00

24.00 1,440.00

20.00 1,960.00

40.00 2,840.00

CF 30,355.00

BF 30,355.00

54.00 182,898.00

56.00 46,088.00

Page 848: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

219.00 108,843.00

11.00 91,817.00

11.00 3,575.00

11.00 15,290.00

11.00 1,188.00

11.00 46,310.00

CF 496,009.00

US Dollar. 1,308,792.00

74.00 4,218.00

33.00 1,617.00

35.00 2,240.00

Page 849: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

17.00 1,088.00

31.00 1,984.00

54.00 1,620.00

76.00 380.00

632.00 43,608.00

CF 56,755.00

BF 56,755.00

3210.00 6,420.00

1415.00 2,830.00

1012.00 1,012.00

749.00 749.00

Page 850: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

35.00 350.00

33.00 132.00

323.00 646.00

17.00 374.00

12513

US Dollar. 69,268.00

Page 851: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

US Dollar. 0.00

US Dollar. 0.00

154816.00 154,816.00

Page 852: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

41016.00 41,016.00

CF 195,832.00

BF 195,832.00

315078.00 315,078.00

NOT IN SCOPE - Provided by Client as per Specs Section 11 6733

89.00 99,235.00

48102.00 48,102.00

76.00 21,052.00

279.00 92,628.00

Provided by Client as per answer for question No (287) dated 23/10/2014

8792.00 8,792.00

4090.00 4,090.00

Page 853: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 588,977.00

BF 588,977.00

1227.00 1,227.00

US Dollar. 786,036.00

Page 854: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

50360.00 50,360.00

US Dollar. 50,360.00

52.00 4,784.00

86.00 1,376.00

193.00 34,161.00

37.00 407.00

1053.00 5,265.00

552.00 552.00

Page 855: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3082.00 36,984.00

1094.00 2,188.00

CF 85,717.00

BF 85,717.00

988.00 988.00

1698.00 1,698.00

461.00 461.00

632.00 1,264.00

96.00 192.00

22.00 6,116.00

Page 856: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

26.00 1,170.00

30.00 1,740.00

37.00 740.00

52.00 4,212.00

65.00 3,185.00

86.00 1,806.00

CF 23,572.00

BF 23,572.00

193.00 8,299.00

21.00 2,226.00

included in item 5 below

included in item 5 below

Page 857: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

61626.00 61,626.00

254.00 1,270.00

CF 73,421.00

BF 73,421.00

2045.00 2,045.00

2045.00 2,045.00

INCLUDED

INCLUDED

INCLUDED

Page 858: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

4,090.00

US Dollar. 186,800.00

25.00 75.00

34.00 136.00

65.00 390.00

96.00 768.00

191.00 4,393.00

235.00 1,410.00

310.00 930.00

included in sanitary fixtures section 224000

Page 859: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

72.00 72.00

110.00 330.00

220.00 1,100.00

263.00 1,052.00

332.00 1,660.00

344.00 344.00

446.00 446.00

1571.00 1,571.00

1640.00 1,640.00

CF 16,317.00

BF 16,317.00

150.00 1,200.00

124.00 10,912.00

Page 860: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

90.00 10,710.00

68.00 4,624.00

54.00 1,296.00

34.00 5,032.00

26.00 286.00

21.00 693.00

17.00 5,406.00

16.00 4,672.00

29.00 174.00

3479.00 10,437.00

4486.00 4,486.00

46.00 782.00

96.00 576.00

46.00 276.00

135.00 135.00

222.00 222.00

252.00 252.00

16843.00 16,843.00

Page 861: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

7561.00 15,122.00

7152.00 7,152.00

included in item 20 to 22 above

CF 101,288.00

BF 101,288.00

11.00 506.00

17.00 1,496.00

29.00 2,291.00

29.00 1,682.00

27.00 135.00

36.00 2,268.00

36.00 2,304.00

Page 862: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

17.00 6,154.00

27.00 378.00

CF 17,214.00

BF 17,214.00

17.00 2,465.00

9.00 630.00

10.00 750.00

12.00 624.00

Page 863: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

14.00 168.00

17.00 221.00

275.00 5,225.00

322.00 1,288.00

482.00 3,856.00

275.00 275.00

192.00 15,168.00

38.00 1,482.00

CF 32,152.00

Page 864: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

BF 32,152.00

666.00 22,644.00

442.00 2,210.00

202.00 4,848.00

171.00 855.00

140.00 1,960.00

43.00 258.00

0.00 0.00

As per the drawing it is integrated

with the Acrylic Countertop

292.00 6,424.00

As per Q&A-383, the sink bowl is

integrated with the Acrylic Countertop

166.00 6,640.00

425.00 425.00

636.00 3,816.00

2704.00 2,704.00

636.00 1,272.00

Page 865: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 54,056.00

BF 54,056.00

11.00 22.00

3151.00 12,604.00

458.00 2,748.00

included

818.00 818.00

7847.00 7,847.00

included

included

24,039.00

US Dollar. 245,066.00

Page 866: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

52.00 71,500.00

12.00 16,824.00

12.00 97,752.00

12.00 167,436.00

CF 353,512.00

BF 353,512.00

58.00 638.00

Page 867: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

60.00 60.00

62.00 186.00

62.00 62.00

64.00 64.00

64.00 128.00

70.00 70.00

70.00 70.00

74.00 296.00

77.00 77.00

78.00 156.00

95.00 190.00

96.00 96.00

82.00 738.00

96.00 192.00

119.00 119.00

145.00 145.00

128.00 128.00

CF 3,415.00

BF 3,415.00

120.00 240.00

Page 868: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

179.00 179.00

179.00 179.00

219.00 219.00

58.00 116.00

58.00 406.00

66.00 3,102.00

76.00 15,048.00

85.00 170.00

85.00 850.00

217.00 434.00

250.00 3,500.00

included in duct

included in duct

included in duct

CF 24,443.00

BF 24,443.00

Page 869: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

22.00 44.00

22.00 132.00

23.00 874.00

25.00 3,875.00

26.00 52.00

26.00 208.00

662.00 662.00

4118.00 4,118.00

1660.00 1,660.00

1505.00 1,505.00

CF 13,130.00

BF 13,130.00

1848.00 1,848.00

964.00 964.00

Page 870: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1632.00 1,632.00

1450.00 1,450.00

801.00 1,602.00

801.00 801.00

542.00 2,168.00

1077.00 2,154.00

606.00 606.00

801.00 801.00

801.00 801.00

1003.00 1,003.00

Page 871: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 15,830.00

BF 15,830.00

963.00 963.00

947.00 1,894.00

892.00 892.00

1028.00 1,028.00

908.00 1,816.00

908.00 908.00

947.00 947.00

947.00 947.00

403.00 403.00

403.00 1,612.00

908.00 908.00

Page 872: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

947.00 947.00

947.00 947.00

1093.00 1,093.00

1038.00 1,038.00

908.00 908.00

CF 17,251.00

BF 17,251.00

1028.00 1,028.00

908.00 908.00

892.00 892.00

892.00 892.00

908.00 908.00

908.00 908.00

1012.00 1,012.00

974.00 974.00

963.00 963.00

908.00 908.00

Page 873: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

908.00 908.00

947.00 947.00

211.00 32,494.00

189.00 8,883.00

CF 52,625.00

BF 52,625.00

115.00 18,860.00

100.00 3,400.00

Page 874: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

223.00 6,244.00

201.00 4,824.00

120.00 1,320.00

139.00 2,085.00

170.00 6,630.00

53.00 477.00

19.00 209.00

76.00 2,964.00

199.00 199.00

190.00 190.00

CF 47,402.00

BF 47,402.00

36.00 2,268.00

Page 875: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

30292.00 30,292.00

29285.00 29,285.00

23120.00 23,120.00

31296.00 62,592.00

15107.00 15,107.00

32795.00 32,795.00

28610.00 28,610.00

28610.00 28,610.00

18384.00 18,384.00

30542.00 61,084.00

29950.00 29,950.00

CF 362,097.00

BF 362,097.00

1913.00 1,913.00

Page 876: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1913.00 1,913.00

3011.00 3,011.00

3413.00 6,826.00

3705.00 3,705.00

4486.00 4,486.00

3705.00 3,705.00

3011.00 3,011.00

3011.00 3,011.00

1913.00 1,913.00

1913.00 1,913.00

18495.00 36,990.00

CF 72,397.00

BF 72,397.00

47231.00 47,231.00

6637.00 6,637.00

CF 53,868.00

Page 877: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

BF 53,868.00

INCLUDED

3272.00 3,272.00

INCLUDED

INCLUDED

INCLUDED

47.00 47.00

83.00 83.00

23.00 23.00

165.00 5,610.00

200.00 4,200.00

298.00 23,840.00

323.00 3,876.00

397.00 9,528.00

532.00 19,152.00

184.00 184.00

170.00 170.00

166.00 166.00

110.00 220.00

110.00 220.00

105.00 105.00

105.00 105.00

99.00 99.00

99.00 99.00

184.00 184.00

167.00 167.00

110.00 110.00

146.00 438.00

Page 878: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

135.00 135.00

98.00 196.00

96.00 192.00

76.00 76.00

73.00 146.00

70.00 70.00

82.00 82.00

70.00 70.00

66.00 66.00

263.00 2,104.00

910.00 1,820.00

32.00 1,696.00

333704.00 333,704.00

412,255.00

US Dollar. 1,428,225.00

22398.00 22,398.00

7926.00 7,926.00

55.00 55.00

4848.00 4,848.00

Page 879: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1082.00 1,082.00

325.00 325.00

27320.00 27,320.00

358.00 358.00

60.00 60.00

30421.00 30,421.00

CF 94,793.00

BF 94,793.00

22140.00 22,140.00

Page 880: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

9856.00 9,856.00

3432.00 3,432.00

25.00 25.00

1850.00 1,850.00

444.00 444.00

143.00 143.00

158.00 158.00

CF 38,048.00

BF 38,048.00

25.00 25.00

As per Q&A # 374 - Not Required

4989.00 4,989.00

26086.00 26,086.00

Page 881: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

20269.00 20,269.00

17737.00 17,737.00

5823.00 5,823.00

18294.00 18,294.00

31426.00 31,426.00

CF 124,649.00

BF 124,649.00

57596.00 57,596.00

65103.00 65,103.00

32682.00 32,682.00

Page 882: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

10.00 470.00

12.00 168.00

20.00 60.00

11.00 132.00

CF 156,211.00

BF 156,211.00

30.00 2,010.00

65.00 3,315.00

Page 883: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

19.00 874.00

1517.00 47,027.00

38971.00 38,971.00

30419.00 30,419.00

127.00 2,032.00

CF 124,648.00

BF 124,648.00

228.00 5,928.00

114.00 22,686.00

110.00 1,650.00

Page 884: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

124.00 22,692.00

114.00 4,902.00

521.00 3,647.00

321.00 5,136.00

260.00 21,320.00

127.00 2,921.00

406.00 4,060.00

129.00 1,419.00

1753.00 15,777.00

2646.00 2,646.00

CF 114,784.00

BF 114,784.00

included

included

included

included

included

Page 885: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

16.00 496.00

144.00 27,792.00

273863.00 273,863.00

39.00 5,733.00

961.00 961.00

308845

US Dollar. 961,978.00

47.00 1,551.00

34.00 374.00

Page 886: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

34.00 34.00

110.00 1,210.00

3611.00 10,833.00

36.00 17,280.00

8.00 2,800.00

1084.00 1,084.00

9.00 900.00

CF 36,066.00

BF 36,066.00

68.00 4,080.00

62.00 124.00

1155.00 5,775.00

1768.00 8,840.00

179.00 895.00

68.00 1,564.00

80.00 1,920.00

97.00 970.00

Page 887: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

76.00 760.00

68.00 1,020.00

68.00 340.00

68.00 340.00

7545.00 15,090.00

included in the above

10.00 10,000.00

10.00 5,500.00

CF 57,218.00

BF 57,218.00

included

included

included

included

included

920.00 1,840.00

32490.00 97,470.00

42914.00 42,914.00

Page 888: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

307579.00 307,579.00

132615.00 132,615.00

581245.00 581,245.00

53491.00 641,892.00

9670.00 29,010.00

1834565

US Dollar. 1,927,849.00

2.00 14,558.00

3.00 21,837.00

8.00 32,920.00

8.00 8,264.00

10.00 4,390.00

Page 889: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

12.00 35,856.00

3.00 28,665.00

4.00 14,760.00

CF 161,250.00

BF 161,250.00

1.00 9,555.00

0.00 0.00

9,555.00

US Dollar 170,805.00

Page 890: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

6,812,643.00

208,086.00

19,038.00

20,689.00

652,500.00

762,080.00

1,308,792.00

69,268.00

0.00

0.00

786,036.00

50,360.00

186,800.00

245,066.00

1,428,225.00

961,978.00

1,927,849.00

170,805.00

15,610,215.00

31,220,430.00

US Dollar 31,220,430.00

Page 891: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Item Nr. Description Unit Qty Rate

03 00 00 - CONCRETE

03 11 13 Structural Cast-in-Place Concrete Forming

1 m3 158 164.00

03 31 00 Structural Concrete

2 Reinforced concrete 35Mpa for strip footing m3 395 380.00

3 Reinforce concrete 35MPa for slab on grade with 7Ø8 / Liner meter thickness 150mm m3 312 296.00

Precast Concrete

4 Precast concrete for super structure item 1 1521618.00

Concrete Topping

5 Sand cement concrete screed with wire mesh thick 50mm for floors above m2 4480 25.00

hollow core slabs.

6 Sand cement foam concrete to slab at roof average 75mm thick m2 1496 17.00

7 Sealed Concrete for beds at roof thick 350mm m3 197 372.00

8 Sealed Concrete for floors to receive finish thick 50mm m2 2992 17.00

03 30 53 - Miscellaneous Cast-in-situ Concrete

9 300mm wide x 200mm high reinforced concrete 35 Mpa for lintel m 356 32.00

10 100mm/200mm wide x 200mm thick reinforced concrete 35 Mpa for lintel m 223 21.00

Total for CONCRETE

CARRIED TO SUMMARY US Dollar.

04 00 00 - Masonry

Plain concrete 20MPa for blinding thickness 100mm for footing and 50mm under slab on grade

Page 892: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

04 22 00 - Concrete Unit Masonry

Internal walls and Partitions

1 250mm thick CMU wall , type 23, m2 42 42.00

As per client answer for question No. 366 Wall type is 200mm thick Non-Fire Rated

2 200mm thick CMU wall reinforced, 1 hour fire rated, type 22A, m2 214 39.00

As per client answer for question No. 366 Wall type is 150mm thick 1 hour Fire Rated

3 150mm thick CMU wall , 2 hour fire rated, type 11A, m2 65 44.00

As per client answer for question No. 366 Wall type is 100mm thick 1 hour Fire Rated

4 150mm thick CMU wall ,1 hour fire rated, type 11, m2 1769 37.00

5 100mm thick CMU wall ,1 hour fire rated, type 1, m2 277 34.00

As per client answer for question No. 366 Wall type is 150mm thick 1 hour Fire Rated

6 100mm thick CMU wall , type 2, m2 659 34.00

7 100mm thick CMU wall reinforcedm vertical Type 1 non fire rated m2 59 37.00

Total for MASONRY

CARRIED TO SUMMARY US Dollar.

05 00 00 METALS

All metalworks herein shall be completed in full compliance with the Drawings SB-A201,

SB-A202, SB-A203,SB-A204,SB-A401 and Specification.

05 70 00 Decorative Metal

1 Supply and fix 50mm diameter stainless steel hand rails including but not limited to m 59 294.00

Page 893: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

12mm diameter stainless steel balustrade, 40mm square stainless steel post with 50mm

x 120mm base plate, for staircase, floor mounted, kind, quality, fittings, fixtures,

accessories as shown on Drawing nr SB-A401 and as per Specification.

2 Supply and fix 50mm diameter stainless steel hand rails for staircase, wall mounted, m 51 113.00

kind, quality, fittings, fixtures, accessories as shown on Drawing nr SB-A401 and as per

Specification.

05 00 00 Metals

Additional Items

3 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

As per Question and Answer No (65)

3.1 Galvanized steel ladder at Elevator Pit, size 350 x 2500mm high nr 2 283.00

Total for METALS

CARRIED TO SUMMARY US Dollar.

06 00 00 WOOD, PLASTICS, AND COMPOSITES

06 61 16 Solid Surfacing Fabrications

1 Supply and fix solid acrylic counter top shaped 2800mm long 550mm wide with 3 nr 12 935.00

opening for wash basin as shown in the Drawing nr SB-A901 and Specification.

2 Supply and fix solid acrylic counter top shaped 1500mm long 550mm wide with 2 nr 2 542.00

opening for wash basin as shown in the Drawing nr SB-A901 and Specification.

06 00 00 WOOD, PLASTICS, AND COMPOSITES

Additional Items

3 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

As per Question and Answer No. (514)

3.1 Aluminum Kitchen Base cabinet with counter top U Shape 18522 x 611 mm nr 1 10875.00

3.2 Counter Top on steel bracket support only at Laundry, Room # GF-58; Size 11500mm length nr 1 4550.00

Page 894: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for WOOD, PLASTICS, AND COMPOSITES

CARRIED TO SUMMARY US Dollar.

07 00 00 THERMAL AND MOISTURE PROTECTION

07 10 00 Damp proofing and Waterproofing

Substructure Waterproofing

All works herein shall be completed in full incompliance with the Drawings nr SB-S001,SBS002,

SB-S003,SB-S101, SB-S102, SB-S201, SB-S202, SB-S203, SB-S204, SB-S401, SB-S402,

SB-S501, SB-S502, SB-S801 and Specification.

1 m2 828 5.00

2 Ditto horizontal surface m2 522 5.00

3 Waterproofing works for substructure with vapour barrier 250 microns, horizontal m2 1626 2.00

surface, as per the Drawings and Specification).

CF

BF

THERMAL AND MOISTURE PROTECTION (Cont'd)

Wet Area Waterproofing / Roof Waterproofing

All works herein shall be completed in full compliance with the Drawings nr SB-A201,SBA202,

SB-A203, SB-A204, SB-A205,SB-SB-A902 and Specification.-

1 Waterproofing works for wet area, vertical surface, w, m2 647 22.00

as per the Drawings and Specification)

2 Waterproofing works for wet area, horizontal surface, m2 335 22.00

as per the Drawings and Specification)

Waterproofing works for substructure with two coats of bitumen paint including elevator pit walls for vertical surface.

Page 895: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3 Waterproofing membrane for roof, horizontal surface, m2 1472 37.00

as per the Drawings and Specification)

4 Geotextile layer for roof water proofing works, horizontal surface, , m2 1472 3.00

as per the Drawings and Specification)

5 100mm thick insulation for water proofing works at roof and balcony water proofing m2 1472 23.00

works, horizontal surface, as per the Drawings and Specification)

07 21 13 Board Insulation

6 Anti-vibration insulation, thickness as per the manufacturers requirements at water tank m2 110 34.00

bearing at room as per the Drawing nr SB-S401 and Specification.

07 72 33 Roof Hatches

7 Supply and fix roof access hatch 1100mm x 1100mm including the heavy-duty folding pull nr 2 514.00

down ladder with telescopic railing as per the manufacturers details, size, kind, quality,

fittings, fixtures, accessories as shown on Drawings nr SB-A934 and as per Specification.

CF

BF

THERMAL AND MOISTURE PROTECTION (Cont'd)

07 72 36 Smoke Vents

1 Supply and fit smoke vent, 1100mm x 1100mm size, kind, quality, fittings, fixtures, nr 2 2966.00

accessories as shown on Drawings nr SB-A934 and as per Specification.

07 00 00 Thermal and Moisture Protection

Additional Items

The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Expansion Joint

1 Walls m 74 43.00

Page 896: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2 Floor m 19 134.00

Total for THERMAL AND MOISTURE PROTECTION

CARRIED TO SUMMARY US Dollar.

08 00 00 OPENINGS

All works herein shall be completed in full compliance with the Doors & Windows Note

Schedule Drawings SB-A801 and Specification.

Note: Notwithstanding the Provisions of the Standard Method of Measurement, door

sets including doors, frames, vision panels, decoration and ironmongery have been

measured as a composite item and the Contractor should make due reference to the

drawings and specification. No claim for lack or want of knowledge will be entertained

08 11 00 Metal Doors and Frames

1 Supply and fix steel flush door, 45mm thick, 1000mm wide x 2200mm high including nr 1 1358.00

frame, type D5,120 minutes fire rated, finished with and including paint, all accessories

and hardware including but not limited to hinges HDH type, out side door lock, lever

handles and latch, wall stop, roses and escutcheons as stated on the drawings and in the

Specification.

08 14 00 - Wood Doors

2 Supply and fix wooden flush teak veneer door, 44mm thick, 1000mm wide x nr 80 1574.00

2200mm high including frame, type D1, 60 minutes fire rated, finished with and including

paint, all accessories and hardware including but not limited to hinges HDH type, inside

door lock, lever handles and latch, wall stop, roses and escutcheons as stated on the

drawings and in the Specification.

3 Supply and fix wooden double swing teak veneer door, 54mm thick, 1000mm nr 4 1753.00

wide x 2200mm high including frame, type D1A, 60 minutes fire rated, finished with and

including paint, all accessories and hardware including but not limited to 12mm thick

laminated tempered glass panel, hinges type, outside door lock, lever handles and latch,

wall stop, roses and escutcheons as stated on the drawings and in the Specification.

4 Supply and fix wooden flush teak veneer door, 44mm thick, 800mm wide x nr 24 952.00

2200mm high including frame, type D2, finished with and including paint, all accessories

and hardware including but not limited to hinges HDH type, inside door lock, lever

handles and latch, wall stop, roses and escutcheons as stated on the drawings and in the

Specification.

Page 897: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF

BF

OPENINGS(Confd)

1 Supply and fix wooden flush door, 54mm thick, 800mm wide x 2200mm high including nr 34 1800.00

frame, type D3, finished with and including paint, all accessories and hardware including

but not limited to hinges HDH type, inside door lock, lever handles and latch, wall stop,

roses and escutcheons as stated on the drawings and in the Specification.

2 Supply and fix wooden flush door with vision panel 200mm x 900mm 12mm laminated nr 16 2505.00

tempered glass, automatic flush bolt for inactive door leaf, 44mm thick, 1000mm wide x

2200mm high including frame, type D4, 120 minutes fire rated, finished with and

including paint, all accessories and hardware including but not limited to hinges HDH

type, inside door lock, lever handles and latch, wall stop, roses and escutcheons as stated

on the drawings and in the Specification.

3 Supply and fix wooden flush door, 54mm thick, 1500mm wide x 2200mm high including nr 3 0.00

frame, type D7, 60 minutes fire rated, finished with and including paint, all accessories

and hardware including but not limited to hinges HDH type, inside door lock, lever

handles and latch, wall stop, roses and escutcheons as stated on the drawings and in the

Specification.

4 Supply and fix wooden flush door, 54mm thick, 1500mm wide x 2200mm high including nr 1 0.00

frame, type D8, 60 minutes fire rated, finished with and including paint, all accessories

and hardware including but not limited to hinges HDH type, inside door lock, lever

handles and latch, wall stop, roses and escutcheons as stated on the drawings and in the

Specification.

08 51 13 Aluminum Windows

5 Supply and fix aluminum window 3150mm wide x 1200mm high, 6mm+ 12mm+6mm nr 72 2220.00

clear tempered glass operable/ fixed panel, including frame, type W1, finished, all

accessories and hardware including but not limited to hinges, handle, lock, weather tight

strip etc. as stated in the Drawings and Specification.

CF

BF

OPENINGS(Cont'd)

1 Supply and fix aluminum window 900mm wide x 1200mm high, 6mm+ 12mm+6mm clear nr 6 441.00

tempered glass fixed panel, including frame, type W2, finished, all accessories and

hardware including but not limited to hinges, handle, lock, weather tight strip etc. as

stated in the Drawings and Specification.

2 Supply and fix aluminum window 1250mm wide x 1200mm high, 6mm+ 12mm+6mm nr 24 881.00

clear tempered glass fixed panel (Frosted glass), including frame, type W3, finished, all

accessories and hardware including but not limited to hinges, handle, lock, weather tight

Page 898: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

strip etc. as stated in the Drawings and Specification.

3 Supply and fix aluminum window 600mm wide x 1200mm high, 6mm+ 12mm+6mm clear nr 24 588.00

tempered glass fixed panel (Frosted glass), including frame, type W4, finished, all

accessories and hardware including but not limited to hinges, handle, lock, weather tight

strip etc. as stated in the Drawings and Specification.

4 Supply and fix aluminum window 825mm wide x 1200mm high, operable metal louvers, nr 4 271.00

including frame, type W5, finished, all accessories and hardware including but not limited

to hinges, handle, lock, weather tight strip etc. as stated in the Drawings and

Specification.

5 Supply and fix aluminum window 6750mm wide x 1100mm high, 6mm+ 12mm+6mm nr 1 4361.00

clear tempered glass fixed panel (Frosted glass), including frame, type W4, finished, all

accessories and hardware including but not limited to hinges, handle, lock, weather tight

strip etc. as stated in the Drawings and Specification.

6 Supply and fix aluminum double glazed window, 6400mm wide x 3550mm high, glass nr 1 13339.00

panel with glass door 1000mm wide 2500mm high(1 nr) including frame, finished, all

accessories and hardware including but not limited to hinges, handle, lock, weather tight

strip etc. as stated in the Drawings and Specification.

7 Supply and fix aluminum double glazed window, 6400mm wide x 3550mm high, glass nr 1 13339.00

panel with glass door 1000mm wide 2500mm high(1 nr) including frame, finished, all

accessories and hardware including but not limited to hinges, handle, lock, weather tight

strip etc. as stated in the Drawings and Specification.

CF

BF

OPENINGS(Cont'd)

1 Supply and fix aluminum double glazed window, 6600mm wide x 3550mm high, glass nr 1 13757.00

panel with glass double door 1400mm wide 2500mm high(2 nr) including frame, type

W7, finished, all accessories and hardware including but not limited to hinges, handle,

lock, weather tight strip etc. as stated in the Drawings and Specification.

2 Supply and fix aluminum double glazed window, 19125mm wide x 3550mm high, glass nr 1 39860.00

panel with glass double door 1400mm wide 2500mm high(1 nr) including frame, type

W8, finished, all accessories and hardware including but not limited to hinges, handle,

lock, weather tight strip etc. as stated in the Drawings and Specification.

3 Supply and fix aluminum double glazed window, 6600mm wide x 3550mm high, glass nr 1 13757.00

panel with glass double door 1400mm wide 2500mm high(1 nr) including frame, type

W9, finished, all accessories and hardware including but not limited to hinges, handle,

lock, weather tight strip etc. as stated in the Drawings and Specification.

Page 899: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

4 Supply and fix aluminum double glazed window, 19100mm wide x 3550mm high, glass nr 1 39808.00

panel with glass double door 1400mm wide 2500mm high(1 nr) including frame, type

W10, finished, all accessories and hardware including but not limited to hinges, handle,

lock, weather tight strip etc. as stated in the Drawings and Specification.

08 83 00 Mirrors

5 Supply and fix fixed mirror 2800mm width x 900mm high for bathrooms (size, kind, nr 12 217.00

quality, surface treatment, method of jointing, etc. as per the Drawings nr SB-A901 and

Specification).

6 Supply and fix fixed mirror 1500mm width x 900mm high for bathrooms (size, kind, nr 2 116.00

quality, surface treatment, method of jointing, etc. as per the Drawings nr SB-A901 and

Specification).

7 Supply and fix fixed mirror 600mm width x 900mm high for bathrooms (size, kind, nr 24 82.00

quality, surface treatment, method of jointing, etc. as per the Drawings nr SB-A901 and

Specification).

CF

BF

OPENINGS(Cont'd)

08 00 00 Openings

Additional Items

1 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

As per Question and Answer No. (514)

1.1 D6 at TV Room / Kitchen / Canteen nr 4 2902.00

Total for OPENINGS

CARRIED TO SUMMARY US Dollar

09 00 00 - FINISHES

09 23 00 Gypsum Boarding, Studwork

Page 900: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1 Gypsum board walls, m2 165 55.00

09 24 00 Cement Plastering

2 15mm thick internal plastering for walls to receive paint m2 4330 22.00

3 Ditto - for walls to receive tiling at wet areas, m2 1300 21.00

CF

BF

FINISHES (Cont'd)

09 30 13 Ceramic Tiling

Floor Tiling

2 Porcelain tile flooring (type - FT7), size 600mm x 600mm, m2 2879 51.00

3 Terrazzo tiles size 400x400mm at roof, m2 1472 32.00

Wall tiling

4 White body wall tile (type WT1) 325mm x 977mm size for toilets and bathroom walls, m2 1081 72.00

Skirting

5 MDF skirting 100mm height, m 2387 17.00

6 Porcelain skirting 100mm height, m 91 19.00

7 Porcelain skirting for staircase 100mm high m 124 19.00

Page 901: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF

BF

FINISHES (Cont'd)

Stair Finish

1 Porcelain tile tread (type - FT7), 230mm wide x 1350mm length, m 166 22.00

2 Porcelain tile for riser (type - FT7), 160mm high x 1350mm length, m 175 16.00

Threshold

09 50 00 Ceilings

4 Supply and install gypsum ceiling, depth of suspension 500 - 1000 mm m2 1247 54.00

as per the drawing

5 Supply and install Moisture resistant gypsum board ceiling for wet areas, m2 349 56.00

09 91 00 - Painting

Wall -Painting

6 Painting for walls, m2 6002 11.00

7 Painting for walls in staircases, m2 752 11.00

Ceiling -Painting

8 Painting for ceiling, m2 1168 11.00

9 Painting for staircase ceiling, m2 191 11.00

10 Painting for ceiling,above gypsum board m2 1596 11.00

CF

Total for FINISHES

CARRIED TO SUMMARY US Dollar.

Page 902: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

` 10 00 00 SPECIALTIES

10 28 00 –Toilet, Bath and Laundry Accessories

Supply & install Plumbing Fixtures as shown in Drawing nr SB-A901 and Technical

Specification including all accessories, fittings , flexible connections etc.

1 Toilet paper holder (TPH) nr 66 21.00

2 Soap dispenser (SD) nr 98 22.00

3 Towel ring nr 98 35.00

4 Robe hook nr 100 17.00

5 Towel bar nr 98 31.00

6 Hook strip nr 12 194.00

10 44 13.13 Portable Fire Extinguishers

All items hereunder to be Supply and installed with all necessary accessories, all in

accordance with the specifications and drawings.

7 Supply & install Portable Fire Extinguishers nr 20 54.00

8 Supply & install fire blanket nr 5 76.00

10 44 13 Fire Protection Cabinets

All Fire suppression works herein shall be completed full incompliance with the Drawings

nr SB-M011, SB-M012, SB-F202, SA-F203 and Specification.

9 Fire hose reel cabinet C/W 2&1/2" pressure restricted type landing valve 2&1/2" nr 12 3082.00

synthetic hose, 1" automatic swinging hose reel, and multipurpose dry powder

extinguisher.

CF

Page 903: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

BF

SPECIALTIES (Cont'd)

10 51 53 Locker Room Benches

1 Supply and fix bench length , 1260mm length, 300mm wide, 400mm high kind and nr 12 748.00

quality and all other accessories as per the Drawing nr SB-A901 and Specification.

10 57 00 Wardrobe and Closet Specialties

2 Supply and fix wardrobe "L" shaped (1660mm + 1160mm) length , 600mm depth, nr 24 1947.00

2500mm high, with melamine laminated shelves, melamine laminated MDF door and

chromed stainless steel handles, and all other accessories as per the Drawing nr SB-A901

and Specification.

3 Supply and fix wardrobe 1500mm length , 600mm depth, 2500mm high, with melamine nr 48 1036.00

laminated shelves, melamine laminated MDF door and chromed stainless steel handles,

and all other accessories as per the Drawing nr SB-A901 and Specification.

4 Supply and fix wardrobe 1950mm length , 600mm depth, 2500mm high, with melamine nr 48 1346.00

laminated shelves, melamine laminated MDF door and chromed stainless steel handles,

and all other accessories as per the Drawing nr SB-A901 and Specification.

10 22 19.23 Demountable Wood Partitions

5 Supply and fix M.D.F laminated partitions, 1500mm length 2500mm high, finished, all nr 24 1994.00

accessories and hardware including but not limited to hinges, handle, etc. as stated in the

Drawing nr SB-A901 and Specification.

6 Supply and fix M.D.F laminated partitions, 1840mm length 2500mm high including 2 nr nr 24 2446.00

doors, finished, all accessories and hardware including but not limited to hinges, handle,

etc. as stated in the Drawing nr SB-A901 and Specification.

10 22 23 Portable Partitions, Screens, and Panels

7 Supply and fix shower screen 8mm thick tempered glass 750mm wide x 2100mm high nr 24 738.00

partition with 700mm x 2000mm flush door, finished, all accessories and hardware

including but not limited to hinges, handle, etc. as stated in the Drawing nr SB-A901 and

Specification.

CF

BF

Page 904: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

SPECIALTIES (Cont'd)

10 00 00 Specialties

Additional Items

1 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

As per Question and Answer No. 514

1.1 Supply and fix M.D.F laminated partitions, 1085mm length 2100mm high including 1 nr door nr 2 1212.00

1.2 Supply and fix M.D.F laminated partitions, 2000mm length 2100mm high including 1 nr door nr 1 2233.00

1.3 Supply and fix M.D.F laminated partitions, 1950mm length 2100mm high including 1 nr door nr 1 2178.00

1.4 MDF Workstation and Bench for Manager Bedroom, 1430 x 750 x 500 high nr 24 330.00

1.5 MDF Workstation and Bench for Staff Bedroom, 3260 x 600 x 800 high nr 48 600.00

1.6 Shelves and drawers, 500 x 600 x 2500 mm high nr 36 665.00

1.7 Towel Pin nr 78 17.00

Total for SPECIALTIES

CARRIED TO SUMMARY US Dollar.

11 00 00 EQUIPMENT

All items hereunder to be described with information such as appropriate to the

procurement , design, supply, execution, type, kind, quality, size, method of fixing ,

specified codes of practice, etc. as per the Drawings and Specification).

11 30 00 Residential Equipment

1 Refrigerator/freezer nr N/A

2 Exhaust hoods nr N/A

Page 905: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3 Cooker nr N/A

4 Washing Machine nr N/A

11 00 00 Equipment

Additional Items

5 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Total for EQUIPMENT

CARRIED TO SUMMARY US Dollar.

12 00 00 FURNISHING

All items hereunder to be described with information such as appropriate to the

procurement , design, supply, execution, type, kind, quality, size, method of fixing ,

specified codes of practice, etc. as per the Drawings and Specification).

12 00 00 Furnishing

Additional Items

1 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Page 906: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for FURNISHING

CARRIED TO SUMMARY US Dollar.

14 00 00 - CONVEYING EQUIPMENT

14 10 10 - PASSENGER ELEVATORS

Contractor Designed Elevators

Supply and install 6 person passenger machine room less lift to serve three floors; refer

Specification for performance capacity, weight load, speed of travel, call system etc.; car

to include floor finish to be as per entrance hallway, mirrored and hardwood ceiling with

recessed and emergency lighting, mirrored and hardwood wall finish, chromium plated

handrails, floor indicator, floor push buttons (including braille floor indicators),

emergency call button/alarm, emergency intercom; each floor to have call button and

floor indicator all as manufacturers recommendations

1 Elevator nr 2 43439.00

Total for CONVEYING EQUIPMENT

CARRIED TO SUMMARY US Dollar.

21 00 00 FIRE SUPPRESSION

All Fire suppression works herein shall be completed full incompliance with the Drawings

nr SA-M011, SA-M012, SA-F201, SA-F202, SA-F203, SA-F204 and Specification.

21 12 23 Fire-Suppression Hose Valves

Supply and installation valves complete and all necessary accessories, all in accordance

with the specifications and drawings.

1 Floor control valve assembly (FCVA) nr 5 1098.00

2 Alarm Check valve, 150mm diameter. nr 1 1698.00

Page 907: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3 OS & Y Valve, 150mm diameter. nr 1 632.00

21 12 00 Fire Suppression Standpipes

Supply & Installation testing and commissioning of steel pipes (painted). All fire fighting

pipes to be completed including but not limited to accessories, fittings, couplings

according to NFPA code/ local civil defence code. Including all kind of supports and

hangers all in accordance to the specifications and drawings.

4 Pipe, 25 mm diameter m 360 22.00

5 Ditto, 32 mm diameter m 22 26.00

6 Ditto, 40 mm diameter m 14 30.00

7 Ditto, 50 mm diameter m 58 37.00

8 Ditto, 65 mm diameter m 222 52.00

9 Ditto, 75 mm diameter m 58 65.00

10 Ditto, 80 mm diameter m 109 65.00

11 Ditto, 100 mm diameter m 227 86.00

12 Ditto, 150 mm diameter m 156 193.00

CF

BF

FIRE SUPPRESSION (Cont'd)

Automatic Air Vent

Supply and Installation of automatic air vent, all in accordance with the specifications and

drawings.

1 Valve, 100 mm diameter. nr 2 461.00

Page 908: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2 Valve, 150 mm diameter. nr 2 632.00

Sprinkler System

Supply and Installation of Sprinkler System, all in accordance with the specifications and

drawings.

3 Sprinkler head Pendent nr 156 35.00

4 Sprinkler head Upright nr 7 18.00

5 Side wall Sprinkler Head nr 72 24.00

21 24 00 Dry-Chemical Fire-Extinguishing Systems

6 Supply and installation of complete Automatic dry powder extinguisher with all nr 6 254.00

necessary accessories, all in accordance with the specifications and drawings.

CF

BF

FIRE SUPPRESSION (Cont'd)

GENERAL

TESTING, ADJUSTING, AND BALANCING OF MEP SYSTEMS

1 Allow for Starting up, pressure testing, complete testing and commissioning for all Fire Item 1 2045.00

fighting system, including all necessary preparations and attendance for authority

approvals.

2 Allow for BMS system to interface with Fire fighting system. Item 1 2045.00

3 Allow for drawing, manuals, approvals & instruction books. Item 1 INCLUDED

4 Allow for protective and decorative painting Item 1 INCLUDED

5 Allow for liaison and coordination with local authorities. Item 1 INCLUDED

6 The contractor to list here and price any items shown in the drawings, mentioned in the

specifications or required for the satisfactory completion of this section as per the

relevant authority regulations, but not mentioned here. Any such item not listed is

deemed to be included.

Page 909: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

21 00 00 Fire Suppression

Additional Items

7 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Total for FIRE SUPPRESSION

CARRIED TO SUMMARY US Dollar.

22 00 00 - PLUMBING

All items hereunder to be described specified code of practice and regulations, kind,

quality, size, method of fixing , finishes or surface treatments, etc. as per the Drawings

and Specification).

22 05 23 General-Duty Valves for Plumbing Piping

Valves

Valves are classified according to type . Material and/or size . Rates include furnishing

and installing of valves, testing at manufacturer's premises and on site; diameters of

valves and water meter according to pipe diameter which will be connected with it; as

per Drawings and Specification.

Gate Valve

1 20 mm diam. nr 24 20.00

1 25 mm diam. nr 27 25.00

2 32 mm diam. nr 24 34.00

3 40 mm diam. nr 50 48.00

4 50 mm diam. nr 12 65.00

5 63 mm diam. nr 8 96.00

5 75 mm diam. nr 4 191.00

6 110 mm diam. nr 8 310.00

Page 910: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Angle Valve

7 20 mm diam. nr 13included in sanitary fixtures section 224000

8 25 mm diam. nr 39included in sanitary fixtures section 224000

Globe Valve

9 63 mm diam. nr 17 263.00

10 50 mm diam. nr 15 220.00

11 40 mm diam. nr 29 159.00

Non-Return Valve

12 40 mm diam. nr 13 45.00

Pressure Reducing Valve

13 110 mm diam. nr 2 2041.00

CF

BF

PLUMBING (Cont'd)

22 11 16 Domestic Water Piping

Domestic water piping is classified by material and diameter. Rates include furnishing

and installing of pipes, fittings, accessories, fixing supports, joints, sleeves, special parts,

connections, hanger supports. Rates to include all works and materials necessary for

complete installation for piping system as per the Drawings and Specification.

Water Supply System

1-Cold Water Supply

Page 911: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1 110 mm diameter. m 26 147.00

2 90 mm diameter. m 167 115.00

3 75 mm diameter. m 68 97.00

4 63 mm diameter. m 20 63.00

5 40 mm diameter. m 221 34.00

6 32 mm diameter. m 48 26.00

7 25 mm diameter. m 218 21.00

8 20 mm diameter. m 312 17.00

2-Hot Water Supply

9 20 mm diameter. m 543 16.00

3 - Accessories

10 Hose Bibb 20mm . nr 13 29.00

11 Water Meter 110 mm. nr 2 4486.00

12 Water Hammer Arrestor nr 43 46.00

13 Automatic Air Vent. nr 8 96.00

14 Pressure Gauge . nr 4 46.00

15 Strainer 75 mm. nr 2 222.00

22 13 16 Sanitary Waste and Vent Piping

Sanitary Pipe Works

Sanitary pipe works is classified by material and diameter. Rates include furnishing and

installing of pipes, fittings, accessories, fixing support, joints, sleeves , special parts,

connections, hanger supports. Rates for pipework below ground also include

excavation, backfilling , civil work, trenches and any other accessories or fittings

necessary for complete installation of the piping system. Testing of pipes at the

manufacturer's premises is included. All as per the Drawings and Specification.

Page 912: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF

BF

PLUMBING (Cont'd)

Pipes and fitting above ground

Waste Pipe

1 50 mm diameter. m 124 11.00

2 75 mm diameter. m 118 17.00

3 110 mm diameter. m 159 29.00

Soil Pipe

4 110 mm diameter. m 259 29.00

Pipes and fitting below ground

Waste pipe

5 75 mm diameter. m 11 27.00

6 110 mm diameter. m 66 36.00

Soil Pipe

7 110 mm diameter. m 69 36.00

Vent Pipe Works

Vent pipes are classified by material and diameter. Rates include furnishing and installing

of pipes, fittings, accessories, fixing support, joints, sleeves, special parts, connections,

hanger supports. Rates include furnishing and installing of pipes, fittings, accessories,

fixing support, joints, sleeves , special parts, connections, hanger supports. Rates for

pipework below ground also include excavation, backfilling , civil work, trenches and any

other accessories or fittings necessary for complete installation of the piping system.

Testing of pipes at the manufacturer's premises is included. All as per the Drawings and

Specification.

Pipes and fittings above ground

Page 913: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

8 75 mm diameter. m 219 17.00

Pipes and fitting below ground

9 75 mm diameter. m 29 27.00

22 13 19.13 Sanitary Drains

Sanitary drains (to include rainwater pipework and condensate drain pipework) are

classified by material and diameter. Rates include furnishing and installing of pipes,

fittings, accessories, fixing supports, joints, sleeves, special parts, connections, hanger

supports. Rates also include testing of pipes at the manufacturer's premises. All as per

the Drawings and specification.

Rain water Pipe

10 75 mm diameter. m 144 17.00

CF

BF

PLUMBING (Cont'd)

Condensate Drain Pipe Works

1 20 mm diameter. m 28 9.00

2 25 mm diameter. m 242 10.00

3 32 mm diameter. m 179 12.00

4 40 mm diameter. m 0

22 33 00 Electric Domestic Water Heaters

Electric domestic water heaters are classified according to capacity. Rates include

furnishing of heater complete with safety valves, air vent, pressure and temperature

relief gauges, drain valves, all valves set (angle, gate, non return, etc. .), thermostat,

heating element, contactors, switch, support, bolts, nuts, connection of pipes, testing on

site, commissioning and putting into service.

Page 914: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

5 EWH-SB-01 with (30 liters / 1200 W) capacity. nr 14 275.00

6 EWH-SB-02 with (100 liters / 1200 W) capacity. nr 24 322.00

7 EWH-SB-03 with (150 liters / 1500 W) capacity. nr 12 482.00

22 40 00 Plumbing Fixtures

All items described hereunder to be of kind, quality, size, nature of base, method of

fixing, complete with accessories etc. as per the Drawings nr V1-903 and Specification

8 Floor Drain (FD) nr 121 192.00

9 Flexible Shower Hose(Sprayer ,valve , etc.) nr 52 38.00

10 Water Closet nr 52 313.00

11 Urinal including (fitting , valve, water and waste connection). nr 24 456.00

12 Floor clean out nr 52 202.00

13 Roof drain nr 5 171.00

14 Vent cap nr 4 43.00

15 Bath tub (BT) including taps, plug, accessories and fitting. nr 0

As per the drawing it is integrated

16 Wash basin (WB) nr 34with the Acrylic Countertop

Page 915: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF

BF

PLUMBING (Cont'd)

As per Q&A no. 358 colthes washing not in contract, only connections

1 Washing machine connections (washing machine not in contract) nr 1 41.00

As per Q&A no. 360 shower channel to be used

2 Shower (SHO) including shower channel, mixer tap, fitting, spray and adjustable bar nr 48 292.00

setting

3 Taps for wash basin including fittings , plugs, valves, connections and waste. nr 34 166.00

22 00 00 - Plumbing

Additional Items

4 Inspection chamber as per Drawings and Specification; connected directly to nr 4 636.00

sewer network.

5 Grease Interceptor as per Drawings and Specification nr 1 2704.00

6 Clean out (CO) nr 38 11.00

7 Roof Water tank as per Specification; rate shall be include supplying and installing, nr 4 8277.00

all fittings, accessories, valves, pipework, vents etc. as per the Drawings and

Specification

8 Gully Trap nr 6 470.00

Additional Items

9 Marking the position of holes, mortices and chases in the structure Item 1 INCLUDED

10 Identification; plates, discs, labels, tapes, bands, arrows, symbols, letters, numbers and Item 1 1227.00

charts; as stated on drawings and in Specification

11 Testing and commissioning of entire installation Item 1 13189.00

CF

BF

PLUMBING (Cont'd)

1 Preparation of as-built drawings Item 1 INCLUDED

Page 916: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2 Preparation of operation and maintenance manuals Item 1 INCLUDED

3 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

3.01 Gate Valve 90 mm Dia No. 12 247.00

3.02 Non-Return Valve 90 mm Dia No. 8 37.00

3.03 1-Cold Water Supply 50 mm Dia Lm. 179 47.00

3.04 Strainer 110 mm Dia 2 363.00

3.05 Scupper Drain 14 127.00

Total for PLUMBING

CARRIED TO SUMMARY US Dollar.

23 00 00 - HEATING, VENTILATING, AND AIR CONDITIONING (HVAC)

All HVAC works shall be completed as per the Drawings and Specification.

23 07 13 Duct Insulations

All items described hereunder to be of type, kind, quality, thickness, method of fixing,

specified codes of practice, etc. as per the Drawings and Specification

1 Supply and fix ductwork insulations outdoor for (supply, return, fresh air, exhaust ,etc.); m2 806 52.00

air duct to include fixing and accessories as per the Drawings and Specification

23 31 00 HVAC Ducts and Casings

All items described hereunder to be of type, kind, quality, size, method of fixing, specified

codes of practice, method of fixing/supports, etc. as per the Drawings and Specification

Notwithstanding the provisions of the Standard Method of Measurement, internal

Page 917: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

ductwork is to include insulation to the ductwork. No claim for additional cost due to lack

or want of knowledge will be entertained

2 Supply and fix insulated indoor galvanized steel sheet metal duct work for all HVAC work Kg 9058 12.00

as specified and as indicating on drawings, complete with bends, supports, connections,

fittings, splices and all accessories to complete the work.

23 33 13.13 Volume-Control Dampers

All items described hereunder to be of type, kind, quality, size, method of fixing, specified

codes of practice, etc. as per the Drawings and Specification

Volume Dampers

3 Volume Damper ; 100x100 mm. nr 110 54.00

4 Volume Damper ; 200x100 mm. nr 2 58.00

5 Volume Damper ; 200x150 mm. nr 1 60.00

CF

BF

23 33 13.13 Volume-Control Dampers

1 Volume Damper ; 250x100 mm. nr 6 60.00

2 Volume Damper ; 250x200 mm. nr 6 64.00

3 Volume Damper ; 300x200 mm. nr 6 66.00

4 Volume Damper ; 300x400 mm. nr 1 74.00

5 Volume Damper ; 500x300 mm. nr 6 78.00

6 Volume Damper ; 650x450 mm. nr 2 125.00

7 Volume Damper ; 250 mm dia. circular damper. nr 27 76.00

23 33 13.16 Fire Dampers

All items hereunder to be described with information such as type, kind, quality, size,

Page 918: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

method of fixing , specified codes of practice, etc. as per the Drawings and Specification).

8 Fire Damper ; Size 250 x 100 mm. nr 6 87.00

23 33 46 Flexible Ducts

All items described hereunder to be of type, kind, quality, size, method of fixing, specified

codes of practice, etc. as per the Drawings and Specification

9 Supply and install flexible duct with insulation; size 250 mm dia. m 49 25.00

23 34 00 HVAC Fans

All items described hereunder to be of capacity, design, supply, execution, type, kind,

quality, size, method of fixing , specified codes of practice, etc. as per the Drawings and

Specification

Supply and install exhaust fan as specified and as indicated in drawing. Fan consists of

casing, fan, motor, control, filter, sand trap louver, all electrical works (components,

wiring, switches etc.) and all accessories. Electrical power supply 220/1/60.

Wall Mounted

10 Exhaust Fan (SEF-B1-01) with total air flow 80 L/S . nr 3 280.00

11 Exhaust Fan (SEF-B2-01) with total air flow 80 L/S . nr 3 280.00

CF

BF

HEATING, VENTILATING, AND AIR CONDITIONING (Cont'd)

Centrifugal Inline Cabinet Type

1 Exhaust Fan (TEF-B1-01-04) with total air flow 600 L/S . (1 Working + 1 Standby) Set 2 3035.00

2 Exhaust Fan (TEF-RF-01) 250 Pa with total air flow 960 L/S . (1 Working +1 Stand by) Set 2 3035.00

Upblast Roof Curb mounted

3 Exhaust Fan (TEF-B3-01) with total air flow 100 L/S . nr 1 532.00

23 37 00 Air outlets and Inlets

All items described hereunder to be of type, kind, quality, size, method of fixing, specified

Page 919: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

codes of practice, etc. as per the Drawings and Specification

Supply and install painted supply linear bar air register with complete accessories as per

the Drawings and Specification

4 Size 2400x250 mm ; 365 L/s. nr 20 329.00

Fresh Air Grille

5 Fresh air grille ; (250X100)mm. nr 1 102.00

Disk Valve

6 Disk Valve ; 100 mm dia . nr 12 36.00

Supply and install roof top package units as specified and according to drawing having

a cooling coil section, supply air fan and air side. Standard mixing box section shall be

provided as well as built in duct heaters. Unit to be mounted on concrete pad with

spring isolators. Electrical power supply 400/3/60.

7 PACU-B3-01; 110 L/s (TV room) Unit 1 15228.00

8 PACU-B3-02; 110 L/s (Canteen) Unit 1 25999.00

CF

BF

HEATING, VENTILATING, AND AIR CONDITIONING (Cont'd)

Page 920: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

23 82 00 Convection Heating and Cooling Units

All items described hereunder to be of capacity, design, supply, execution, type, kind,

quality, size, method of fixing , specified codes of practice, etc. as per the Drawings and

Specification

Supply and install Fresh Air Handing unit as specified and as indicated in drawing. Unit

to be complete with air cooled condensing unit , fan , pre filter ,bag filter, damper and

sand trap louver with filter , valves ,Sound attenuator, control , all electrical works

(components , wiring , etc. .) and all accessories. Electrical power supply 380/3/60.

1 (FAHU-BH-01) , 2,525 L / s , 500 Pa ; Heating Capacity 27.7 KW . nr 1 37448.00

2 (FAHU-B2-01) , 2,460 L / s , 500 Pa ; Heating Capacity 27.0 KW . nr 1 43087.00

Supply and install concealed fan coil unit as specified and as indicated in drawing. Unit

to be complete with air cooled condensing unit, fan, filter, valves, controls, thermostat,

all electrical works (components, wiring, switches etc.) and all accessories. Electrical

power supply 220/1/60.

Ground Floor - Building-1

3 (FCU-B1GF1) , 216 L / s , 75 Pa ; Sensible Capacity 2.4 KW . nr 1 1625.00

4 (FCU-B1GF2) , 168 L / s , 75 Pa ; Sensible Capacity 1.9 KW . nr 1 1179.00

5 (FCU-B1GF3) , 168 L / s , 75 Pa ; Sensible Capacity 1.9 KW . nr 1 1179.00

6 (FCU-B1GF4) , 168 L / s , 75 Pa ; Sensible Capacity 1.9 KW . nr 1 1179.00

7 (FCU-B1GF5) , 168 L / s , 75 Pa ; Sensible Capacity 1.9 KW . nr 1 1179.00

8 (FCU-B1GF6) , 168 L / s , 75 Pa ; Sensible Capacity 1.9 KW . nr 1 1179.00

9 (FCU-B1GF7) , 168 L / s , 75 Pa ; Sensible Capacity 1.9 KW . nr 1 1179.00

10 (FCU-B1GF8) , 216 L / s , 75 Pa ; Sensible Capacity 2.4 KW . nr 1 1625.00

11 (FCU-B1GF9) , 274 L / s , 75 Pa ; Sensible Capacity 3.0 KW . nr 1 1625.00

12 (FCU-B1GF10) , 227 L / s , 75 Pa ; Sensible Capacity 2.5 KW . nr 1 1625.00

13 (FCU-B1GF11) , 227 L / s , 75 Pa ; Sensible Capacity 2.5 KW . nr 1 1625.00

14 (FCU-B1GF12) , 274 L / s , 75 Pa ; Sensible Capacity 3.0 KW . nr 1 1625.00

Ground Floor - Building-2

Page 921: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

15 (FCU-B2GF1) , 204 L / s , 75 Pa ; Sensible Capacity 2.3 KW . nr 1 1625.00

16 (FCU-B2GF2) , 154 L / s , 75 Pa ; Sensible Capacity 1.7 KW . nr 1 1179.00

17 (FCU-B2GF3) , 154 L / s , 75 Pa ; Sensible Capacity 1.7 KW . nr 1 1179.00

18 (FCU-B2GF4) , 154 L / s , 75 Pa ; Sensible Capacity 1.7 KW . nr 1 1179.00

19 (FCU-B2GF5) , 154 L / s , 75 Pa ; Sensible Capacity 1.7 KW . nr 1 1179.00

20 (FCU-B2GF6) , 154 L / s , 75 Pa ; Sensible Capacity 1.7 KW . nr 1 1179.00

21 (FCU-B2GF7) , 154 L / s , 75 Pa ; Sensible Capacity 1.7 KW . nr 1 1179.00

22 (FCU-B2GF8) , 204 L / s , 75 Pa ; Sensible Capacity 2.3 KW . nr 1 1625.00

CF

BF

HEATING, VENTILATING, AND AIR CONDITIONING (Cont'd)

1 (FCU-B2GF9) , 288 L / s , 75 Pa ; Sensible Capacity 3.2 KW . nr 1 1625.00

2 (FCU-B2GF10) , 241 L / s , 75 Pa ; Sensible Capacity 2.7 KW . nr 1 1625.00

3 (FCU-B2GF11) , 241 L / s , 75 Pa ; Sensible Capacity 2.7 KW . nr 1 1625.00

4 (FCU-B2GF12) , 288 L / s , 75 Pa ; Sensible Capacity 3.2 KW . nr 1 1625.00

Ground Floor - Building-3

5 (FCU-B3-01) , 269 L / s , 75 Pa ; Sensible Capacity 3.0 KW . nr 1 1625.00

6 (FCU-B3-02) , 197 L / s , 75 Pa ; Sensible Capacity 2.2 KW . nr 1 1625.00

First Floor - Building-1

(FCU-B1TGF1) , 216 L / s , 75 Pa ; Sensible Capacity 2.4 KW . nr 1 1625.00

7 (FCU-B1TGF2) , 168 L / s , 75 Pa ; Sensible Capacity 1.9 KW . nr 1 1179.00

8 (FCU-B1TGF3) , 168 L / s , 75 Pa ; Sensible Capacity 1.9 KW . nr 1 1179.00

9 (FCU-B1TGF4) , 168 L / s , 75 Pa ; Sensible Capacity 1.9 KW . nr 1 1179.00

10 (FCU-B1TGF5) , 168 L / s , 75 Pa ; Sensible Capacity 1.9 KW . nr 1 1179.00

11 (FCU-B1TGF6) , 168 L / s , 75 Pa ; Sensible Capacity 1.9 KW . nr 1 1179.00

Page 922: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

12 (FCU-B1TGF7) , 168 L / s , 75 Pa ; Sensible Capacity 1.9 KW . nr 1 1179.00

13 (FCU-B1TGF8) , 216 L / s , 75 Pa ; Sensible Capacity 2.4 KW . nr 1 1625.00

14 (FCU-B1TGF9) , 274 L / s , 75 Pa ; Sensible Capacity 3.0 KW . nr 1 1625.00

15 (FCU-B1TGF10) , 227 L / s , 75 Pa ; Sensible Capacity 2.5 KW . nr 1 1625.00

16 (FCU-B1TGF11) , 227 L / s , 75 Pa ; Sensible Capacity 2.5 KW . nr 1 1625.00

17 (FCU-B1TGF12) , 274 L / s , 75 Pa ; Sensible Capacity 3.0 KW . nr 1 1625.00

First Floor - Building-2

18 (FCU-B2TGF1) , 204 L / s , 75 Pa ; Sensible Capacity 2.3 KW . nr 1 1625.00

19 (FCU-B2TGF2) , 154 L / s , 75 Pa ; Sensible Capacity 1.7 KW . nr 1 1179.00

20 (FCU-B2TGF3) , 154 L / s , 75 Pa ; Sensible Capacity 1.7 KW . nr 1 1179.00

21 (FCU-B2TGF4) , 154 L / s , 75 Pa ; Sensible Capacity 1.7 KW . nr 1 1179.00

22 (FCU-B2TGF5) , 154 L / s , 75 Pa ; Sensible Capacity 1.7 KW . nr 1 1179.00

23 (FCU-B2TGF6) , 154 L / s , 75 Pa ; Sensible Capacity 1.7 KW . nr 1 1179.00

24 (FCU-B2TGF7) , 154 L / s , 75 Pa ; Sensible Capacity 1.7 KW . nr 1 1179.00

25 (FCU-B2TGF8) , 204 L / s , 75 Pa ; Sensible Capacity 2.3 KW . nr 1 1625.00

26 (FCU-B2TGF9) , 325 L / s , 75 Pa ; Sensible Capacity 3.7 KW . nr 1 1625.00

27 (FCU-B2TGF10) , 241 L / s , 75 Pa ; Sensible Capacity 2.7 KW . nr 1 1625.00

28 (FCU-B2TGF11) , 241 L / s , 75 Pa ; Sensible Capacity 2.7 KW . nr 1 1625.00

29 (FCU-B2TGF12) , 325 L / s , 75 Pa ; Sensible Capacity 3.7 KW . nr 1 1625.00

CF

BF

HEATING, VENTILATING, AND AIR CONDITIONING (Cont'd)

Second Floor - Building-1

1 (FCU-B1F1) , 253 L / s , 75 Pa ; Sensible Capacity 2.8 KW . nr 1 1625.00

2 (FCU-B1F2) , 206 L / s , 75 Pa ; Sensible Capacity 2.3 KW . nr 1 1625.00

Page 923: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3 (FCU-B1F3) , 206 L / s , 75 Pa ; Sensible Capacity 2.3 KW . nr 1 1625.00

4 (FCU-B1F4) , 206 L / s , 75 Pa ; Sensible Capacity 2.3 KW . nr 1 1625.00

5 (FCU-B1F5) , 206 L / s , 75 Pa ; Sensible Capacity 2.3 KW . nr 1 1625.00

6 (FCU-B1F6) , 206 L / s , 75 Pa ; Sensible Capacity 2.3 KW . nr 1 1625.00

7 (FCU-B1F7) , 206 L / s , 75 Pa ; Sensible Capacity 2.3 KW . nr 1 1625.00

8 (FCU-B1F8) , 253 L / s , 75 Pa ; Sensible Capacity 2.8 KW . nr 1 1625.00

9 (FCU-B1F9) , 310 L / s , 75 Pa ; Sensible Capacity 3.5 KW . nr 1 1625.00

10 (FCU-B1F10) , 263 L / s , 75 Pa ; Sensible Capacity 3.0 KW . nr 1 1625.00

11 (FCU-B1F11) , 263 L / s , 75 Pa ; Sensible Capacity 3.0 KW . nr 1 1625.00

12 (FCU-B1F12) , 310 L / s , 75 Pa ; Sensible Capacity 3.5 KW . nr 1 1625.00

Second Floor - Building-2

13 (FCU-B2LF1) , 239 L / s , 75 Pa ; Sensible Capacity 2.7 KW . nr 1 1625.00

14 (FCU-B2LF2) , 195 L / s , 75 Pa ; Sensible Capacity 2.2 KW . nr 1 1625.00

15 (FCU-B2LF3) , 195 L / s , 75 Pa ; Sensible Capacity 2.2 KW . nr 1 1625.00

16 (FCU-B2LF4) , 195 L / s , 75 Pa ; Sensible Capacity 2.2 KW . nr 1 1625.00

17 (FCU-B2LF5) , 195 L / s , 75 Pa ; Sensible Capacity 2.2 KW . nr 1 1625.00

18 (FCU-B2LF6) , 195 L / s , 75 Pa ; Sensible Capacity 2.2 KW . nr 1 1625.00

19 (FCU-B2LF7) , 195 L / s , 75 Pa ; Sensible Capacity 2.2 KW . nr 1 1625.00

20 (FCU-B2LF8) , 239 L / s , 75 Pa ; Sensible Capacity 2.7 KW . nr 1 1625.00

21 (FCU-B2LF9) , 325 L / s , 75 Pa ; Sensible Capacity 3.7 KW . nr 1 1625.00

22 (FCU-B2LF10) , 279 L / s , 75 Pa ; Sensible Capacity 3.1 KW . nr 1 1625.00

23 (FCU-B2LF11) , 279 L / s , 75 Pa ; Sensible Capacity 3.1 KW . nr 1 1625.00

24 (FCU-B2LF9) , 325 L / s , 75 Pa ; Sensible Capacity 3.7 KW . nr 1 1625.00

23 05 93 Testing, Adjusting and Balancing for HVAC

Page 924: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

All items hereunder to be described with type of installation, preparatory operations,

stages of test (nr), required attendance, applicable codes etc. as per the Drawings and

Specification).

25 Air balancing of the ducting network Item 1 4090.00

26 Testing, balancing and commissioning of all the equipment Item 1 11532.00

CF

BF

HEATING, VENTILATING, AND AIR CONDITIONING (Cont'd)

23 00 00 - Heating, Ventilating, and Air Conditioning (HVAC)

Additional Items

1 Marking the position of holes, mortices and chases in the structure Item 1 INCLUDED

2 Identification; plates, discs, labels, tapes, bands, arrows, symbols, letters, numbers and Item 1 614.00

charts; as stated on drawings and in Specification

3 Testing and commissioning of entire installation Item 1 INCLUDED

4 Preparation of as-built drawings Item 1 INCLUDED

5 Preparation of operation and maintenance manuals Item 1 INCLUDED

6 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

6.1 Fresh Air Grille, 100x100 nr. 78 39.00

6.2 Square supply ceiling diffuser, Size 450X450 mm ; 160 L/s. nr. 14 170.00

6.3 Fire Damper, 500 x 300 nr. 5 92.00

6.4 Fire Damper, 500 x 400 nr. 1 113.00

6.5 Fire Damper, 300 x 300 nr. 1 90.00

6.6 Fire Damper, 300 x 200 nr. 1 87.00

6.7 Fire Damper, 350 x 300 nr. 4 92.00

Page 925: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

6.8 Fire Damper, 450 x 300 nr. 4 95.00

6.9 Motorized Fire Damper, 250 x 100 nr 6 787.00

6.10 Refrigerant piping, 20 mm diameter with max liquid line 10 mm. m 878 31.00

6.11 Building Management System Item 1 189415.00

Total for HVAC

CARRIED TO SUMMARY US Dollar.

26 00 00 - ELECTRICAL

All works hereunder shall be completed as per the Drawings and Specification.

26 05 19 Low Voltage Electrical Power Conductors and cables

All items hereunder to be of type, kind, number of cores, armoring and sheathings,

method of fixing , specified codes of practice, etc. as per the Drawings and Specification).

Notwithstanding the Provisions of the method of measurement, cables have been

itemized and referenced to the circuit. The contractor is to make due reference to Staff

Building Electrical Drawings for full details and is to allow for all cabling, junctions,

flexible connections, feeder units etc. required to complete the installation in accordance

with the drawings and Specification. No claim for want or lack of knowledge will be

entertained

1 Lighting circuits Item 1 16362.00

2 Power circuits Item 1 9062.00

3 Fire alarm circuits Item 1 28.00

4 Water heater circuits Item 1 2706.00

5 Fan circuits Item 1 596.00

6 HVAC control circuits Item 1 15345.00

7 Emergency lighting circuits Item 1 701.00

Page 926: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

8 Lift power circuits Item 1 872.00

9 Lightning protection Item 1 13960.00

CF

BF

26 05 26 Grounding and Bonding for Electrical Systems

All items hereunder to be described with information such as type, kind, number of

cores, armoring and sheathings, method of fixing , specified codes of practice, etc. as per

the Drawings and Specification).

1 Grounding system Item 1 13634.00

26 05 33.13 Conduit for Electrical Systems

All items hereunder to be described with information such as type, kind, , method of

fixing , specified codes of practice, etc. as per the Drawings and Specification).

Notwithstanding the Provisions of the method of measurement, conduits have been

itemized and referenced to the circuit. The contractor is to make due reference to Staff

Building Electrical Drawing for full details and is to allow for all cabling, junctions, flexible

connections, feeder units etc. required to complete the installation in accordance with

the drawings and Specification. No claim for want or lack of knowledge will be

entertained

2 Lighting circuits Item 1 8067.00

3 Power circuits Item 1 4122.00

4 Fire alarm circuits Item 1 13.00

5 Water heater circuits Item 1 1110.00

6 Fan circuits Item 1 245.00

9 Emergency lighting circuits Item 1 346.00

10 Lift power circuits Item 1 121.00

Page 927: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF

BF

26 05 36 Cable Trays for Electrical Systems

All items hereunder to be described with information such as type, kind, , method of

fixing , specified codes of practice, etc. as per the Drawings and Specification).

Notwithstanding the Provisions of the method of measurement, cable trays have been

included as a lump sum and referenced to size. The contractor is to make due reference

to Staff Building Electrical Drawings for full details and is to allow for all cable trays,

junctions, flexible connections etc. required to complete the installation in accordance

with the drawings and Specification. No claim for want or lack of knowledge will be

entertained

1 Galvanized steel cable tray 200 x 100 Item 1 7656.00

2 Galvanized steel cable tray 400 x 100 Item 1 1546.00

3 Galvanized steel cable tray with cover 200 x 100 Item 1 4944.00

4 Galvanized steel cable tray with cover 100 x 100 Item 1 424.00

5 Galvanized steel cable tray with cover 400 x 100 Item 1 4602.00

6 Galvanized steel cable tray with cover 600 x 100 Item 1 3217.00

7 Cable ladders for electrical system Item 1 3169.00

26 24 13 Switchboards

5 All items hereunder to be described with information such as type, kind, rated capacity,

method of fixing, cores reference to Specification, fuses, background, specified codes of

practice, etc. as per the Drawings and Specification).

26 24 16 Panel boards

All items hereunder to be described with information such as type, kind, rated capacity,

method of fixing, cores reference to Specification, fuses, codes of practice, etc. as per

the Drawings and Specification).

Page 928: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF

BF

1 Main distribution boards Item 1 29205.00

2 Sub-main distribution boards Item 1 17920.00

26 27 13 Electricity Metering

3 All items hereunder to be described with information such as type, kind, rated capacity, Item 1 1939.00

method of fixing, cores reference to Specification, fuses, codes of practice, etc. as per

the Drawings and Specification).

26 27 26 Wiring Devices

Switches & Push Buttons

All items hereunder to be described with information such as appropriate to the

procurement , type, kind, quality, size, method of fixing , specified codes of practice, etc.

as per the Drawings and Specification).

4 One way one gang switch nr 173 10.00

5 One way two gang switch nr 73 12.00

Power Outlets

6 Single outlet nr 6 9.00

7 Double outlet nr 229 19.00

8 Double outlet; NEMA 5-18R; weather proof grounding type nr 6 58.00

9 Single point shaver outlet nr 30 92.00

Page 929: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF

BF

Power Outlets (cont'd)

1 Single point refrigerator outlet nr 24 9.00

2 Single point fire alarm control panel outlet nr 2 9.00

3 Fusible disconnect switch plate, double poles, 32A, 220V, 60HZ, with lamp Indicator for nr 50 19.00

water heater

4 Single point main telecom cabinet outlet nr 1 9.00

6 nr 25 9.00

7 Infusable disconnect switch 1 pole nr 79 47.00

8 Infusable disconnect switch 3 pole nr 4 1530.00

26 50 00 Lighting

All items hereunder to be described with information such as appropriate to the

procurement , type, kind, quality, size, method of fixing , specified codes of practice, etc.

as per the Drawings and Specification).

9 Luminaire, surface mounted fluorescent lamp with diffuser, 2 x 36W; type A1 nr 30 190.00

10 Luminaire, recess mounted with diffuser in frame, 4 x 18W; type B1 nr 10 228.00

11 Luminaries, recess mounted down light, compact fluorescent lamp with closed dome nr 77 114.00

reflector, 2 x 26W CFL; type D1

12 Luminaries, recess mounted down light, compact fluorescent lamp with closed dome nr 19 278.00

reflector, and battery back-up 2 x 26W CFL; type D1E

CF

BF

1 Luminaries, recess mounted down light, compact fluorescent lamp with reflector, 1 x nr 24 110.00

26W CFL; type D2

2 Luminaries, surface mounted down light, compact fluorescent lamp with opal wrap nr 195 419.00

around diffuser, 2 x 26W CFL; type D4

Fusible disconnect switch plate, double poles, 30A, 220V, 60HZ for TV (NORMAL SOCKET OUTLET AS PER Q&A # 539)

Page 930: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3 Luminaire, LED ceiling mounted, round shape; 1 x 21W, 220V, 60hz; type R2 nr 302 176.00

4 Luminaire, LED ceiling mounted, round shape with battery back-up; 1 x 21W, 220V, 60hz; nr 42 503.00

type R2E

5 Luminaire, wall mounted 1 x 26W CFL with glass cover; type W1 nr 5 370.00

6 Luminaire, wall mounted fluorescent, steel chrome/plastic, white 4 x 26W; type W2 nr 64 102.00

7 Luminaire, up/down wall mounted; 2 x 26W CDL; type W3 nr 102 260.00

8 Luminaire, wall mounted CDL; 2 x 18W with aluminum dome reflector; type W4 nr 12 222.00

9 Luminaire, wall mounted CDL; 2 x 18W with aluminum dome reflector and battery back nr 12 385.00

up; type W4E

10 Luminaire, self contained exit light with directional arrow nr 25 129.00

26 00 00 - Electrical

Additional Items

11 Marking the position of holes, mortices and chases in the structure Item 1 included

12 Identification; plates, discs, labels, tapes, bands, arrows, symbols, letters, numbers and Item 1 included

charts; as stated on drawings and in Specification

CF

BF

1 Testing and commissioning of entire installation Item 1 included

2 Preparation of as-built drawings Item 1 included

3 Preparation of operation and maintenance manuals Item 1 included

4 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Page 931: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

4.01 Feeder cable from Main distribution board to Distribution boards (As per Q&A # 537) Item 1 27520.00

Total for ELECTRICAL

CARRIED TO SUMMARY US Dollar.

27 00 00 COMMUNICATIONS

Telecommunication / Low Current

STRUCTURED CABLING SYSTEM

Supply, Install, Test, connect and commission inclusive of all cabling, conduits and

containment, socket outlets, all in accordance with the relevant service provider

regulations , rules, recommendation and requirements and in accordance with the

specifications and drawings.

1 Information Outlet, Flush Type 1 DATA, 1 Telephone 0.3 Meters A.F.F.L. nr 131 47.00

2 Telephone Outlet, Wall Mounted Flush Type, MTD 0.30m A.F.F.L nr 38 34.00

3 Telephone Outlet, Wall Mounted, Flush Type 1.2 Meters A.F.F.L. nr 10 34.00

4 TV outlet, wall mounted 0.3 meters A.F.F.L. nr 25 34.00

5 15U Telecom Cabinet, Wall Mounted nr 4 2561.00

6 Main Telecom Cabinet - 42U Free Standing Rack nr 1 6206.00

7 Set Top Box nr 25AS PER Q&A # 317 NOT IN THE SCOPE

8 LED TV nr 25AS PER Q&A # 317 NOT IN THE SCOPE

Page 932: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

9 CAT 6A, UTP Cable m 9295 10.00

10 Single Mode Fiber Optic Cable - 4 x 2 Core m 150 8.00

Consumption Metering

Supply, Install, Test, connect and commission inclusive of all cabling, conduits and

containment, socket outlets, all in accordance with the relevant service provider

regulations , rules, recommendation and requirements and in accordance with the

specifications and drawings.

11 Main Entrance Station nr 1 1084.00

12 M-bus Cable, 2 x 18AWG nr 120 10.00

CF

BF

Fire Alarm System

Supply, install, connection, testing and commissioning of wiring and equipment for Fire

Alarm System including all necessary materials and accessories to reflect complete

system installation.

1 Addressable, smoke detector nr 20 68.00

2 Addressable, smoke detector with sound base nr 97 85.00

3 Addressable, heat detector nr 1 62.00

4 Addressable, Manual Pull Station nr 18 68.00

5 Fire Alarm Horn With Strobe nr 29 80.00

6 MultiSensor Detector nr 13 97.00

7 Fault Isolator nr 13 76.00

8 Control Module nr 10 68.00

9 Control Module for Tamper Switch nr 5 68.00

10 Control Module for Flow Switch m 5 68.00

Page 933: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

11 Duct Smoke Detector m 6 179.00

12 Fire Alarm Control Panel nr 1 8424.00

13 Power Supply Unit, 24v nr 2 included in the above

14 Loop Cable, 2x1.5mm2 Fire Resistant m 881 10.00

15 24V Cable, 2x2.5mm2 Fire Resistant m 350 10.00

CF

BF

Additional Items

1 Marking the position of holes, mortises and chases in the structure Item 1 included

2 Identification; plates, discs, labels, tapes, bands, arrows, symbols, letters, numbers and Item 1 included

charts; as stated on drawings and in Specification

3 Testing and commissioning of entire installation Item 1 included

4 Preparation of as-built drawings Item 1 included

5 Preparation of operation and maintenance manuals Item 1 included

6 The Contractor is to list here and price any items shown on the Drawings, mentioned in

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

ADDITIONAL (As per Q&A 487)

1 ACTIVE COMPONENTS (AS PER Q&A 487) DISTRIBUTION CABINET nr 4 9670.00

2 ACTIVE COMPONENTS (AS PER Q&A 487) MAIN CABINET CABINET nr 1 21196.00

Total for COMMUNICATIONS

CARRIED TO SUMMARY US Dollar.

Page 934: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

31 00 00 EARTHWORK

All works herein shall be completed in full compliance with the Drawings nr SB-S001,SBS002,

SB-S003,SB-S004,SB-S005,SB-S401and Specification.

31 10 00 Site Clearing

1 Site preparation, clearing site vegetation m2 1750 2.00

31 23 16 Excavation

2 Excavating top soil for preservation, average depth 150mm. m2 1750 3.00

3 Excavating pits (49 nr), maximum depth ≤ 2.00m. m3 1512 8.00

4 Excavating trenches for grade beams, width ≤ 0.3m m3 130 10.00

31 23 23 .13 Backfill

5 Filling to excavations, average thickness > 0.25 m, arising from excavated materials, all fill m3 888 12.00

shall be compacted to 75% relative density for cohesion-less soils as per ASTM

D4254/ASTM D4293 or 95% maximum density as determined by ASTM D698 for cohesive

material, as per the Drawings and Specifications).

31 23 23.23 Compaction

6 Surface treatments, compacting bottom of excavation, compaction to meet 85% of m2 2675 3.00

relative density for cohesion-less soils or 95% maximum density as determined by ASTM

D1557 for cohesive materials per the Drawings and Specifications)

31 23 16.26 Rock Removal

7 Disposal of excavated material, off site as stated in the Specification. m3 1012 4.00

CF

BF

31 31 16 Termite Control

1 Termite control for the horizontal surface (method and type of treatment as per the m2 2674 1.00

Drawings and Specifications)

2 Termite control for vertical surface (method and type of treatment as per the Drawings m2 2730 0.00

and Specifications)

Page 935: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Additional Items

3 The Contractor is to list here and price any items shown on the Drawings, mentioned in Item

the Specifications or required for the satisfactory completion of this section, but not

mentioned here. Any such items not listed below shall be deemed to be included.

Total for EARTHWORK

CARRIED TO SUMMARY US Dollar

03 00 00 Concrete

04 00 00 Masonry

05 00 00 Metal

06 00 00 Wood, Plastics and Composites

07 00 00 Thermal and Moisture Protection

08 00 00 Openings

09 00 00 Finishes

10 00 00 Specialties

11 00 00 Equipment

12 00 00 Furnishing

14 00 00 Conveying Equipment

21 00 00 Fire Suppression

22 00 00 Plumbing

23 00 00 Heating, Ventilating and Air Conditioning (HVAC)

26 00 00 Electrical

27 00 00 Communications

31 00 00 Earthwork

Page 936: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

AMOUNT FOR STAFF BUILDING FORWARD TO SUMMARY US Dollar

Page 937: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Amount

25,912.00

150,100.00

92,352.00

1,521,618.00

112,000.00

25,432.00

73,284.00

50,864.00

11,392.00

4,683.00

2,067,637.00

Page 938: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1,764.00

8,346.00

2,860.00

65,453.00

9,418.00

22,406.00

2,183.00

112,430.00

17,346.00

Page 939: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

5,763.00

566.00

23,675.00

11,220.00

1,084.00

10,875.00

4,550.00

Page 940: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

27,729.00

4,140.00

2,610.00

3,252.00

10,002.00

10,002.00

14,234.00

7,370.00

Page 941: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

54,464.00

4,416.00

33,856.00

3,740.00

1,028.00

119,108.00

119,108.00

5,932.00

3,182.00

Page 942: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2,546.00

11660

140,770.00

1,358.00

125,920.00

7,012.00

22,848.00

Page 943: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

157,138.00

157,138.00

61,200.00

40,080.00

0.00

0.00

159,840.00

261,120.00

261,120.00

2,646.00

21,144.00

Page 944: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

14,112.00

1,084.00

4,361.00

13,339.00

13,339.00

70,025.00

70,025.00

13,757.00

39,860.00

13,757.00

Page 945: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

39,808.00

2,604.00

232.00

1,968.00

111,986.00

111,986.00

11,608.00

611,877.00

Page 946: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

9,075.00

95,260.00

27,300.00

131,635.00

131,635.00

146,829.00

47,104.00

77,832.00

40,579.00

1,729.00

2,356.00

Page 947: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

316,429.00

316,429.00

3,652.00

2,800.00

67,338.00

19,544.00

66,022.00

8,272.00

12,848.00

2,101.00

17,556.00

200,133.00

648,197.00

Page 948: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1,386.00

2,156.00

3,430.00

1,700.00

3,038.00

2,328.00

1,080.00

380.00

36,984.00

52,482.00

Page 949: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

52,482.00

8,976.00

46,728.00

49,728.00

64,608.00

47,856.00

58,704.00

17,712.00

294,312.00

294,312.00

Page 950: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2,424.00

2,233.00

2,178.00

7,920.00

28,800.00

23,940.00

1,326.00

68,821.00

415,615.00

Page 951: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

0.00

Page 952: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

0.00

86,878.00

86,878.00

5,490.00

1,698.00

Page 953: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

632.00

7,920.00

572.00

420.00

2,146.00

11,544.00

3,770.00

7,085.00

19,522.00

30,108.00

90,907.00

90,907.00

922.00

Page 954: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1,264.00

5,460.00

126.00

1,728.00

1,524.00

11,024.00

11,024.00

2,045.00

2,045.00

Page 955: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

4090

106,021.00

480.00

675.00

816.00

2,400.00

780.00

768.00

764.00

2,480.00

Page 956: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

included in sanitary fixtures section 224000

included in sanitary fixtures section 224000

4,471.00

3,300.00

4,611.00

585.00

4,082.00

26,212.00

26,212.00

Page 957: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3,822.00

19,205.00

6,596.00

1,260.00

7,514.00

1,248.00

4,578.00

5,304.00

8,688.00

377.00

8,972.00

1,978.00

768.00

184.00

444.00

Page 958: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

70,938.00

70,938.00

1,364.00

2,006.00

4,611.00

7,511.00

297.00

2,376.00

2,484.00

Page 959: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3,723.00

783.00

2,448.00

27,603.00

27,603.00

252.00

2,420.00

2,148.00

Page 960: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3,850.00

7,728.00

5,784.00

23,232.00

1,976.00

16,276.00

10,944.00

10,504.00

855.00

172.00

As per the drawing it is integrated

with the Acrylic Countertop

Page 961: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

86,141.00

86,141.00

41.00

14,016.00

5,644.00

2,544.00

2,704.00

418.00

33,108.00

2,820.00

1,227.00

13,189.00

75,711.00

75,711.00

Page 962: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2,964.00

296.00

8,413.00

726.00

1,778.00

14177

300,782.00

41,912.00

Page 963: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

108,696.00

5,940.00

116.00

60.00

156,724.00

156,724.00

360.00

384.00

396.00

74.00

468.00

250.00

2,052.00

Page 964: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

522.00

1,225.00

840.00

840.00

7,411.00

7,411.00

6,070.00

6,070.00

532.00

Page 965: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

6,580.00

102.00

432.00

15,228.00

25,999.00

61,013.00

61,013.00

Page 966: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

37,448.00

43,087.00

1,625.00

1,179.00

1,179.00

1,179.00

1,179.00

1,179.00

1,179.00

1,625.00

1,625.00

1,625.00

1,625.00

1,625.00

Page 967: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1,625.00

1,179.00

1,179.00

1,179.00

1,179.00

1,179.00

1,179.00

1,625.00

107,683.00

107,683.00

1,625.00

1,625.00

1,625.00

1,625.00

1,625.00

1,625.00

1,625.00

1,179.00

1,179.00

1,179.00

1,179.00

1,179.00

Page 968: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1,179.00

1,625.00

1,625.00

1,625.00

1,625.00

1,625.00

1,625.00

1,179.00

1,179.00

1,179.00

1,179.00

1,179.00

1,179.00

1,625.00

1,625.00

1,625.00

1,625.00

1,625.00

43,398.00

43,398.00

1,625.00

1,625.00

Page 969: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1,625.00

1,625.00

1,625.00

1,625.00

1,625.00

1,625.00

1,625.00

1,625.00

1,625.00

1,625.00

1,625.00

1,625.00

1,625.00

1,625.00

1,625.00

1,625.00

1,625.00

1,625.00

1,625.00

1,625.00

1,625.00

1,625.00

Page 970: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

4,090.00

11,532.00

54,622.00

54,622.00

614.00

3,042.00

2,380.00

460.00

113.00

90.00

87.00

368.00

Page 971: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

380.00

4,722.00

27,218.00

189,415.00

228889.00

659,740.00

16,362.00

9,062.00

28.00

2,706.00

596.00

15,345.00

701.00

Page 972: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

872.00

13,960.00

59,632.00

59,632.00

13,634.00

8,067.00

4,122.00

13.00

1,110.00

245.00

346.00

121.00

Page 973: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

27,658.00

27,658.00

7,656.00

1,546.00

4,944.00

424.00

4,602.00

3,217.00

3,169.00

Page 974: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

25,558.00

25,558.00

29,205.00

17,920.00

1,939.00

1,730.00

876.00

54.00

4,351.00

348.00

2,760.00

Page 975: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

59,183.00

59,183.00

216.00

18.00

950.00

9.00

225.00

3,713.00

6,120.00

5,700.00

2,280.00

8,778.00

5,282.00

33,291.00

33,291.00

2,640.00

81,705.00

Page 976: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

53,152.00

21,126.00

1,850.00

6,528.00

26,520.00

2,664.00

4,620.00

3,225.00

204,030.00

204,030.00

Page 977: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

27,520.00

27,520.00

436,872.00

6,157.00

1,292.00

340.00

850.00

10,244.00

6,206.00

AS PER Q&A # 317 NOT IN THE SCOPE

AS PER Q&A # 317 NOT IN THE SCOPE

Page 978: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

92,950.00

1,200.00

1,084.00

1,200.00

121,523.00

121,523.00

1,360.00

8,245.00

62.00

1,224.00

2,320.00

1,261.00

988.00

680.00

340.00

340.00

Page 979: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1,074.00

8,424.00

included in the above

8,810.00

3,500.00

38,628.00

38,628.00

38,680.00

21,196.00

59876

220,027.00

Page 980: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3,500.00

5,250.00

12,096.00

1,300.00

10,656.00

8,025.00

4,048.00

44,875.00

44,875.00

2,674.00

0.00

Page 981: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

47,549.00

2,067,637.00

112,430.00

23,675.00

27,729.00

140,770.00

611,877.00

648,197.00

415,615.00

0.00

0.00

86,878.00

106,021.00

300,782.00

659,740.00

436,872.00

220,027.00

47,549.00

Page 982: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

5,905,799.00

Page 983: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Item Nr. Description Unit Qty Rate

03 00 00 - CONCRETE

03 11 13 Structural Cast-in Place Concrete Forming

1 m³ 5 188.00

03 31 00 Structural Concrete

2 m³ 15 402.00

3 m³ 9 592.00

4 m³ 12 387.00

Notwithstanding the Provisions of the Standard Method of Measurement of Building Works Seventh Edition, 1988 (SMM7) the following,concrete works are measured m³/m including. reinforcement bars and formworks. The Contractor is to include for cost of reinforcement and formwork with concrete works. No additional charge or cost for reinforcement and formwork separately will be entertained due to lack or want of knowledge.

All concrete works herein shall be completed in full compliance with the Drawings and Specification.

Plain Concrete, 20 Mpa for blinding Beds, Thickness ≤ 150mm. Poured againts the compacted soil, as the Structural Notes and Specification.

Reinforced concrete 35 Mpa, foundations ( footings): kind,quality, curing details etc. as stated in the Structural Notes and Specification.

Reinforced concrete 35 Mpa for ground beams; kind,quality, curing details etc. as stated in the Structural Notes and Specification.as stated in the Structural Notes and Specification.

Reinfoced concrete beds 35 Mpa for slab with A393 welded wire mesh, on grade; thickness ≤ 150mm, poured againts the compacted soil kind quality, curing details etc.as stated in the Structural Notes and Specification.

Page 984: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

5 m³ 2 684.00

6 m³ 12 614.00

7 m³ 18 636.00

8 m² 4 838.00

CF

BF

CONCRETE (Cont'd)

1 m³ 16 705.00

Reinforced concrete for substructure columns35 Mpa up to slab on grade; kind quality, curing details etc.as stated in the Structural Notes and Specification

Reinforced concrete 35 Mpa super structure slab, thickness 150mm, (kind,quality, curing details etc. as stated in the Structural Notes and Specification.

Reinforced concrete 35 Mpa for super structure slabs, thickness 200mm, (kind,quality, curing details etc. as stated in the Structural Notes and Specification.

Reinforced concrete parapet wall at roof, 200mm thick,vertical, (kind,quality, type of bond, mix of mortar etc. to be included as per the Specification.

Reinforced concrete 35 Mpa for superstructure beams, (kind quality, curing details etc. as stated in the Structural Notes and Specification.

Page 985: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2 m³ 7 1185.00

3 m³ 3 1051.00

03 30 53 - Miscellaneous Cast-in-Situ Concrete

4 200mm wide x 200mm high reinforced concrete 35 Mpa for lintel m 56 21.00

5 100mm wide x 200mm high reinforced concrete 35 Mpa for lintel m 56 11.00

03 53 00 Concrete Topping

6 m² 80 17.00

7 m 80 17.00

03 00 00 - Concrete

m 32 0.00

Additional Items

Reinforced concrete 35 Mpa for superstructure columns, (kind quality, curing details etc. as stated in the Structural Notes and Specification.

Reinforced concrete 35 Mpa for staircases, (kind,quality, curing details etc. as stated in the Structural Notes and Specification.

Sand cement/concrete screed for floors, width > 300mm, (thickness,kind quality,composition mix, nature of base method of construction. Layout and treatments,thermal insulation,moisture resistant treatment method of jointing, etc, as per the Drawings and Specification.

Sealed concrete for roof areas, width > 300mm, (thickness,kind qualityquality, composition mix, nature of base method of construction. Layout and treatments,thermal insulation,moisture resistant treatment method of jointing, etc, as per the Drawings and Specification.

Precast concrete sills, 300mm x 200mm sloping to 175mm; fair finished; bedding and pointing in cement mortar; all as drawing GH-801, detail 2

As per client answer for question No (283), the cost of precast sill to be added in masonry items

Page 986: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

8

AMOUNT FOR CONCRETE TO SUMMARY US Dollar

04 00 00 - Masonry

04 22 00 - Concrete Unit Masonry

Internal walls and Partitions

1 m² 34 34.00

External walls

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included

All Masonry works herein shall be completed full incompliance with the Drawings and Specification.

100mm thick CMU wall reinforced, vertical, (kind, quality and size of blocks,; type of bond, mix of motar etc. to be included as per the Specification).

Page 987: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2 m² 227 90.00

04 00 00 - Masonry

Additional Items

3

3.1 200 mm blocks at parapet m² 119.13 39.00

300mm thick CMU wall, vertical, comprised with 150mm block work external side, 50mm insulation, 100mm block work internal side, (kind, quality and size of blocks,; type of bond, mix of motar etc. to be included as per the Specification).

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section,but not mentioned here.Any such items not listed below shall be deemed to be included.

Page 988: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

AMOUNT FOR MANSORY TO SUMMARY US Dollar

05 00 00 METALS

05 70 00 - Decorative Metal

1 m 9 294.00

05 00 00 Metals

Additional Items

2

All metals works herein shall be completed in full compliance with the Drawin and Specification.

Supply and fix 50mm x 50mm galvanized steel 40 mm square stainless steel handrail post, W/50mm x 120mm base plate including 12mm ballustrade; powder coated hand rails for staircase, floor mounted, kind, quality, fittings, fixtures, accessories as shown on Drawings GH-A906 and as per Specification.

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section,but not mentioned here.Any such items not listed below shall be deemed to be included.

Page 989: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

AMOUNT FOR METAL TO SUMMARY US Dollar

06 00 00 WOOD, PLASTIC, AND COMPOSITES

06 41 00 - Architectural Wood Casework

1 nr 1 5420.00Supply and fix wasting area counter 2500mm long, 600mm wide with side wall 2400mm high and door, counter to be solid acrylic counter top, Base unit to have 2Nr 1000mm x 400mm deep shelves, side wall to be made of MDF both side on studs 100 x 50 at 400mm centres, Door to be solid core with hinges, lever handles and latch, the whole structure to be paint finished with primer, undercoat and matt finish.

Page 990: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2 nr 1 3388.00

06 61 16 Solid Surfacing Fabrications

3 nr 1 299.00

4 nr 1 514.00

5 nr 1 670.00

6 nr 1 432.00

06 00 00 Wood, Plastic, and Composites

Additional Items

7

As per Question and Answer question No (514)

7.1 Closet, 1450 x 600 x 3250 full height nr 1 1517.00

Supply and install free standing CCTV room control desk in hardwood including two sets of drawers on runners, U-shaped desk and executive chair.

Supply and fix solid acrylic counter top shaped 1450mm long 600mm wide on gallows brackets to guard room counter area as per the Drawing nr and Specification.

Supply and fix solid acrylic counter top shaped 2500mm long 600mm wide on gallows brackets to guard room counter area as per the Drawing nr and Specification.

Supply and fix solid acrylic counter top shaped 3800mm long 500mm wide on gallows brackets to guard room counter area as per the Drawing nr and Specification.

Supply and fix solid acrylic counter top shaped 2100mm long 600mm wide on gallows brackets to guard room counter area as per the Drawing nr and Specification.

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Page 991: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

AMOUNT FOR WOOD, PLASTIC, AND COMPOSITES TO SUMMARY US Dollar

07 00 00 THERMAL AND MOISTURE PROTECTION

07 10 00 Damp proofing and Waterproofing

Substructure Waterproofing

1 m² 106 5.00

2 m² 38 5.00

3 m² 139 2.00

Wet Area Waterproofing / Roof Waterproofing

All works herein shall be completed in full compliance with the Drawings and Specification.

Waterproofing works for substructure with two coast of bitumen paint, vertical surface, as per the Drawings and Specification)

Waterproofing works for substructure with two coast of bitumen paint, horizontal surface, per the Drawings and Specification)

Waterproofing works for substructure with vapour barrier 250 microns,horizontal surface, as per the Drawings and Specification)

Page 992: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

4 m² 12 22.00

5 m² 4 22.00

6 m² 80 37.00

7 m² 80 3.00

8 m² 80 23.00

CF

BF

Thermal and Moisture Protection (Cont'd)

07 72 33 Roof Hatches

All works herein shall be completed in full compliance with the Drawings and Specification.

Waterproofing works for wet area, vertical surface, as per the Drawings and Specification)

Waterproofing works for wet area, horizontal surface, as per the Drawings and Specification)

Waterproofing membrane for roof, horizontal surface, as per the Drawings and Specification)

Geotextile layer for roof area water proofing works, horizontal surface, as per the Drawings and Specification)

100mm thick insulation for water proofing works at roof terrace water proofing works horizontal surface, as per the Drawings and Specification)

Page 993: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1 nr 1 5030.00

07 72 33 Roof Hatches

Additional Items

2

Supply and fix roof access hatch 110mm x 1100mm size, including heavy duty folding pull down ladder with telescopic railing; kind quality, fittings, fixtures, accessories as shown on drawing nr GH-A903, GH-A906 and specification.

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Page 994: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

US Dollar

08 00 00 OPENINGS

Note

08 11 13 - Metal Doors and Frames

AMOUNT FOR THERMAL AND MOISTURE PROTECTION CARRIED TO SUMMARY

All works herein shall be completed in full compliance with the Doors & windows, Schedule Drawings and Specification.

Notwithstanding the Provisions of the Standard Method of Measurement, doors, frames, vision panels, decoration and ironmongery have been measured as a composite item and The Contractor should make due reference to the drawings and specification. No claim for lack or want of knoledge will be entertained.

Page 995: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1 nr 2 2935.00

2 nr 1 1576.00

08 14 00 - Wood Doors

3 nr 1 952.00

4 nr 1 2385.00

Supply and fix glazed steel door, 45mm thick, 1000mm wide x 2200mm high including steel frame type D1, 6mm tinted glass panel, 700mm x 1350mm fixed with steel glazing beads finished with and including including paint, all accessories and hardware including but not limited to hinges HDH type, MO closer, inside lock, lever handles and latch, wall stop roses as stated in the Specification.

Supply and fix glazed steel door, 45mm thick, 1000mm wide x 2200mm high including steel frame type D12 6mm tinted glass panel, 700mm x 1350mm and with view window frame fixed with steel glazing beads finished with and including including paint, all accessories and hardware including but not limited to hinges HDH type, MO closer, deadlock, lever handles and latch, door stopper, roses and escutheon as stated in the Specification. Window aluminum framed double glazed unit, 800mm x 1550mm high, type W5, finished fixed light as tated in the Drawings Specification

Supply and fix wooden flush door, 44mm thick, 800mm wide x 2200mm high including steel frame type D3, finished with and including including paint, all accessories and hardware including but not limited to hinges HDH type, thumb turn and indicator, lever handles and latch, wall stop as stated in the Specification.

Supply and fix solid phenolic door, frame and panel, 12.5mm thick,overall 1650mm wide x 2000mm high including frame type D4, self finished with including including all accessories and hardware including but not limited to lift off hinges door stopper, thumb turn and indicator, wall stop as stated in the Specification.

Page 996: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF

BF

OPENINGS (Cont'd)

08 51 13 Aluminum Windows

1 nr 7 2688.00

2 nr 6 2688.00

Supply and fix aluminum double glazed window (glazing to be ballistic resistant burglary resistant and blast resistant, 2000mm wide 1700mm high, fixed window including frame, type W1 powder coated finish, all accessories. and hardware including but not limited to weather tight strip etc; as stated in the Drawing and Specification.

Supply and fix aluminum double glazed window (glazing to be ballistic resistant burglary resistant and blast resistant, 1000mm wide 1700mm high, opening light including frame, type W2 powder coated finish, awning window, all accessories. and hardware including but not limited to weather tight strip etc; as stated in the Drawing and Specification.

Page 997: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3 nr 4 2688.00

4 nr 1 6860.00

5 nr 1 2688.00

6 nr 1 271.00

Supply and fix aluminum double glazed window (glazing to be ballistic resistant burglary resistant and blast resistant, 1000mm wide 1700mm high, opening light including frame, type W6 powder coated finish, awning window, all accessories. and hardware including but not limited to weather tight strip etc; as stated in the Drawing and Specification.

Supply and fix aluminum double glazed window (glazing to be ballistic resistant burglary resistant and blast resistant, 1000mm wide 1700mm high, opening light including frame, type W4 powder coated finish, awning window, all accessories. and hardware including but not limited to weather tight strip etc; as stated in the Drawing and Specification.

Supply and fix aluminum double glazed window (glazing to be ballistic resistant burglary resistant and blast resistant, 1000mm wide 1700mm high, fixed window including frame, type W5 powder coated finish, awning window, all accessories. and hardware including but not limited to weather tight strip etc; as stated in the Drawing and Specification.

Supply and fix aluminum double glazed window (glazing to be ballistic resistant burglary resistant and blast resistant, 4500mm wide x 1200mm high,in 5 fixed lights including frame, type W6 powder coated finish, all accessories. and hardware including but not limited to weather tight strip etc; as stated in the Drawing and Specification.

Page 998: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF

BF

Aluminum Windows (Cont'd)

08 83 00 Mirrors

1 nr 1 82.00

08 00 00 Openings

Additional Items

2

Supply and fix fixed mirror 650mm width x 1050mm high for bathrooms ( size, kind, quality, surface treatment, method of jointing, etc; as per the Drawings and Specification).

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Page 999: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

AMOUNT FOR OPENINGS TO SUMMARY US Dollar

09 00 00 - FINISHES

09 23 00 Gypsum Plastering

09 23 00 Gypsum Plastering

1 m² 96 0.00

2 m² 4 0.00

09 24 00 Cement Plastering

All works herein shall be completed in full compliance with the Schedule Drawings and Specification.

Note: Notwithstanding the provision of the Standard method of measurement, corner ans stop beads are deemed to included with plastering. The Contractor is to make all due allowance for these items and No. claim for want of knoledge will be entertained.

Gypsum plastering for ceiling to receive paint finish, width > 300mm, (thickness, kind quality, composition, mix materials, nature of base, method of construction layout and treatment, thermal insulation, moisture resistant treatment, method of jointing and joint reinforcement etc, as per the Drawings nr GH-A201, 501,701, 901 and Specification).

Gypsum plastering for ceiling to receive paint finish at toilets, laundry and bathrooms, width > 300mm, (thickness, kind quality, composition, mix materials, nature of base, method of construction layout and treatment, thermal insulation, moisture resistant treatment, method of jointing and joint reinforcement etc, as per the Drawings nr GH-A201, 501,701, 901 and Specification).

Page 1000: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3 m² 325 22.00

4 m² 98 22.00

5 m² 20 21.00

6 m² 282 29.00

Plastering for walls to receive paint finish, width > 300mm, (thickness, kind quality, composition, mix materials, nature of base, method of construction layout and treatment, thermal insulation, moisture resistant treatment, method of jointing etc; as per the Drawings GH-A901 and Specification).

Plastering for walls in stair areas, width > 300mm, (thickness, kind quality, composition, mix materials, nature of base, method of construction layout and treatment, thermal insulation, moisture resistant treatment, method of jointing and etc; as per the Drawings nr GH-A201, GH-A202 &GH-A901 and Specification).

Plastering for walls to receive tiling at wet areas, width > 300mm, (thickness, kind quality, composition, mix materials, nature of base, method of construction layout and treatment, thermal insulation, moisture resistant treatment, method of jointing and etc; as per the Drawings nr GH-A201, GH-A501, GH-A701 &GH-A901 and Specification).

Self coloured rendering ( pre coloured mineral wall coating ) for walls, external, width > 300mm, (thickness, kind, mix materials, nature of base, method of construction layout and treatment, thermal insulation, moisture resistant treatment, method of jointing, etc; as per the Drawings nr GH-A201, GH-A202 &GH-A901 and Specification).

Page 1001: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF

BF

FINISHES (Cont'd)

1 m² 61 29.00

09 30 13 Ceramic Tiling

Floor Tilling

2 m² 101 51.00

3 m² 4 51.00

Self coloured rendering ( pre coloured mineral wall coating ) for parapet walls, width > 300mm, (thickness, kind, mix materials, nature of base, method of construction layout and treatment, thermal insulation, moisture resistant treatment, method of jointing, etc; as per the Drawings nr GH-A201, GH-A202 &GH-A901 and Specification).

Porcelain tile flooring (type - F17) 600mm x 600mm, level or to falls only ≤ 15 * from horizontal, fixed over cement sand screed ( screed measured separately). selected colour, thickness, method of construction, layout and treatments, method of jointing and etc; as per the Drawings and Specification.

Porcelain tile flooring, slip resistant at wet area (type - F17) 300mm x 300mm, level or to falls only ≤ 15 * from horizontal, fixed over cement sand screed ( screed measured separately). selected colour, thickness, method of construction, layout and treatments, method of jointing and etc; as per the Drawings and Specification.

Page 1002: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

4 m² 80 32.00

Wall Tiling

5 m² 21 64.00

Skirting

6 m 46 17.00

Terrazzo tile flooring, level or to falls only ≤ 15 * from horizontal, fixed over 20mm mortar bed and 20mm layer sand at roof, thickness, kind quality, size, method of construction layout and treatment, method of jointing etc, as per the Drawings and Specification).

Wall tile fine porcelain (type - WT8) 300mm x 300mm size for toilet,width > 300mm, fixedover cement sand plaster, thickness, method of construction, layout and treatments, method of jointing and etc; as per the Drawings and Specification.

MDF skirting 150mm height, vertical, fixed over cement sand plaster (thickness , kind, quality, size,nature of base, method of construction, layout and treatment, method of jointing, etc, as per the Drawings and Specification).

Page 1003: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF

BF

FINISHES (Cont'd)

1 m 24 22.00

2 m 26 19.00

09 50 00 Ceilings

3 m² 101 54.00

4 m² 4 56.00

09 91 00 - Painting

Wall - Painting

5 m² 325 11.00

Porcelain tile skirting 150mm height (type - FT1) for CCTV control room area, fixed over cement sand plastering, thickness, method of construction, layout and treatments, method of jointing and etc; as per the Drawings and Specification.

MDF skirting 150mm height, vertical, fixed over cement sand plaster for staircase (thickness , kind, quality, size,nature of base, method of construction, layout and treatment, method of jointing, etc, as per the Drawings and Specification).

Supply and install gypsum ceiling, depth of suspension 500 - 1000 mm ( thickness of lining and method of fixing system to structure,kind, quality, size,nature of background, insulation materials etc, as per the Drawings nr GH-A501, GH-A901 and Specification)

Supply and install gypsum ceiling,for toilets, and wash room, depth of suspension 500 - 1000 mm ( thickness of lining and method of fixing system to structure,kind, quality, size,nature of background, insulation materials etc, as per the Drawings nr and Specification)

Painting for walls, girth > 300mm, (kind, quality of materials, painted on cement plastering, preparatory works, priming coat, undercoats, finishing coat method of application,etc, as per the Drawing and Specification.

Page 1004: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

6 m² 98 11.00

CF

BF

FINISHES (Cont'd)

Ceiling - Painting

1 m² 101 11.00

2 m² 4 11.00

09 00 00 - FINISHES

Additional Items

Painting for walls in staircases, girth > 300mm, (kind, quality of materials, nature of base, preparatory works, priming coat, undercoats, finishing coat method of application,etc, as per the Drawing and Specification.

Painting (type PT1) for ceiling, girth ≤ 300mm, (kind, quality of materials, painted on cement plastering, preparatory works, priming coat (1nr), undercoats (1nr), finishing coat (1nr) method of application,etc, as per the Drawing and Specification.

Painting (type PT1) for staircase ceiling, girth ≤ 300mm, (kind, quality of materials, painted on cement plastering, preparatory works, priming coat (1nr), undercoats (1nr), finishing coat (1nr) method of application,etc, as per the Drawing and Specification.

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Page 1005: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3

Stair Finishes

3.01 Treads, 280 mm wide LM 18.5 24.00

3.02 Risers, 170mm high LM 19 20.00

3.03 Porcelaiin tile skirting 100mm high LM 27.96 19.00

Painting for walls, girth > 300mm, (kind, quality of materials, painted on cement plastering, preparatory works, priming coat , undercoats, finishing coat method of application etc; as per the Drawings UB-CB-A204, UB-CB-A802 and Specification.

Page 1006: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

AMOUNT FOR FINISHES TO SUMMARY US Dollar

10 00 00 SPECIALTIES

10 28 00 - Toilet,Bath and Laundry Accessories

1 Paper towel dispenser (PTD) nr 1 21.00

2 Soap dispenser (SD) nr 1 22.00

3 Robe hook nr 1 17.00

10 44 13.13 Portable Fire Extinguishers

4 Supply & install Portable Fire Extiguesher nr 1 54.00

10 00 00 SPECIALTIES

Additional Items

5

Supply & install Plumbing Fixtures as shown in Drawing and Technical Specification including all accessories, fittings, flexible connection etc.

All Items hereunder to be described with kind, quality, size, method of fixing,etc, as per the Drawings and Specification.

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Page 1007: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

AMOUNT FOR SPECIATIES TO SUMMARY US Dollar

11 00 00 EQUIPMENT

Additional Items

1 The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Page 1008: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

AMOUNT FOR EQUIPMENT TO SUMMARY US Dollar

12 00 00 FURNISHING

Page 1009: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Additional Items

1 nr 1 2533.00

2 nr 1 0.00

All Items hereunder to be described with information such as appropriate to the procurement design supply, execution,type kind quality, size, method of fixing specified codes of practice ,etc, as per the Drawings and Specification)

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Supply and fix 3970mm long 450mm width bench: solid acrylic at waiting area as per the drawing nr GH-A201 and Specification.

Supply and install desk 600 + 2800 + 600 mm long 600mm width; solid acrylic at CCTV control room as per the drawing nr GH-A201 and Specification.

Page 1010: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

AMOUNT FOR FURNISHING TO SUMMARY US Dollar

22 00 00 - PLUMBING

22 05 23 General-Duty Valves for Plumbing Piping

Valves

Gate Valve

All Items hereunder to be described specified code of practice and regulation, kind quality, size method of fixing, finishes or surface treatments etc,as per the Drawings and Specification)

Valves are classified according to type. Material and/ or size. Rates include furnishing and installing of valves, testing at manufacturer's premises and on site: diameter of valves and water meter according to pipe diameter which will be connected with it; as per the Drawings and Specification)

Page 1011: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1 20 mm diam. nr 1 20.00

2 50 mm diam. nr 1 65.00

Angle Valve

3 20 mm diam. nr 2included in sanitary fixtures section 224000

Non- Return Valve

4 20 mm diam. nr 2 19.00

Pressure Reducing Valve

5 50 mm diam. nr 1 366.00

22 11 16 Domestic Water Piping

Water Supply System

1-Cold Water Supply

6 50 mm diameter. m 5 45.00

7 20 mm diameters m 5 16.00

2-Hot Water Supply

8 20mm diameter m 5 16.00

3 - Accessories

9 Water Meter 50 mm. nr 1 1618.00

10 Water Hammer Arrestor nr 1 45.00

11 Automatic Air Vent. nr 1 96.00

12 Strainer 50 mm. nr 1 96.00

Domestic water piping is classified by material and diameter, rates include furnishing and installing of pipe, fittings, accessories, fixing supports, joints, sleeves, special parts, connections, hanger supports, rates to include all works and materials necessary for complete installation for piping system as per the Drawings and Specification)

Page 1012: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF

BF

PLUMBING (Cont'd)

22 13 16 Sanitary Waste and Vent Piping

Sanitary Pipe Works

Pipes and Fittings above ground

Waste pipe

1 50 mm diameter. m 3 11.00

Soil pipe

2 110 mm diameter m 5 29.00

Pipes and Fittings below ground

Water pipe

3 75 mm diameter m 3 27.00

Vent pipes

Sanitary pipe works is classified by material and diameter, rates include furnishing and installing of pipe, fittings, accessories, fixing supports, joints, sleeves, special parts, connections, hanger supports, rates for pipework below ground also excavation, backfilling, civil work, trenches and any other accessories or fittings, necessary for complete installation for piping system as per the Drawings and Specification)

Page 1013: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Pipes and fittings above ground

4 75 mm diameter. m 8 17.00

Pipes and fittigns below ground

5 75 mm diameter m 4 27.00

CF

BF

PLUMBING (Cont'd)

22 13 16 Sanitary Waste and Vent Piping

Vent pipe are classified by material and diameter, rates include furnishing and installing of pipe, fittings, accessories, fixing supports, joints, sleeves, special parts, connections, hanger supports, rates for pipework below ground also excavation, backfilling, civil work, trenches and any other accessories or fittings, necessary for complete installation for piping system Testing of pipes at the manufacturer's premises in included, All as per the Drawings and Specification)

Sanitary drains ( to include rainwater pipework nd condensate drain pipework). Are classified by material and diameter, rates include furnishing and installing of pipe, fittings, accessories, fixing supports, joints, sleeves, special parts, connections, hanger supports, rates also include testing of pipes at manufacturer's premises. All as per the Drawings and Specification)

Page 1014: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Rain water Pipe

1 75 mm diameter. m 15 17.00

Condensate Drain Pipe Works

2 20 mm diameter. m 15 9.00

22 33 00 Electric Domestic Water Heaters

3 EWH-V1-01 with (150 liters / 1200W) capacity. nr 1 482.00

22 40 00 Plumbing Fixtures

4 Floor Drain (FD) nr 1 192.00

5 Flexible Shower Hose nr 1 38.00

6 Water closet nr 1 313.00

7 Floor clean out nr 1 202.00

8 Roof drain nr 1 171.00

9 Vent cap nr 1 43.00

10 Wash basin (WB) nr 1 171.00

11 Taps for wash basin including fittings, plugs, valves, connections and waste. nr 1 166.00

Electric domestic water heaters. Are classified according to capacity, Rates include furnishing of heater complete with safety valves, air vent, pressure and temperature relief gauges, drain vlaves, all valves set (angle, gate, non return, etc) thermonstant heating, element, contractors, switch, supports, bolts, nuts, connections,of pipes, testing on site commissioning and putting service.

All items described hereunder to be kind, quality, size, nature of base, method of fixing, complete with accssories etc; as per the Drawings and Specification.

Page 1015: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF

BF

PLUMBING (Cont'd)

22 00 00 - PLUMBING

Additional Items

1 nr 1 636.00

.

2 Clean out (CO) nr 1 202.00

3 Gully Trap nr 1 458.00

Additional Items

4 Marking the position of holes, mortises and chases in the structure Item 1 INCLUDED

5 Item 1 205.00

6 Testing and commissioning and maintenance manuals Item 1 205.00

7 Preparation of as-built drawings Item 1 818.00

8 Preparation of maintanance manuals Item 1 INCLUDED

Inspection chamber as per Drawings and Specification; connected directly to sewer network.

Identification; plates, dics, labels, tapes, bands, arrows; symbols, letters, numbers and charts; as stated on drawings and in Specification.

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Page 1016: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

AMOUNT FOR PLUMBING TO SUMMARY US Dollar

23 00 00 - HEATING, VENTILATING, AND AIR CONDITONING (HVAC)

All HVAC works shall be completed as per the Drawings and Specification

23 23 00 Refrigerant Piping

2 20 mm diameter with max liquid line 10 mm. m 6 33.00

Supply and fix refrigerant pipes for FCU from condensing units to indoor installed AC units including fittings, sleeves and all accessories as per the Drawings and Specification)

Page 1017: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF

BF

HVAC (Cont'd )

All Items hereunder to be described to be of capacity, design, supply, execution,type, kind quality, size, fixing specified codes of practice,etc, as per the Drawings and Specification)

Page 1018: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Wall Mounted

1 Exhaust fan (CF-01) 40 Pa with total air flow 25 L/S, 220/1/60Hz nr 1 133.00

23 82 00 Convection Heating and Cooling Units

2 (FCU-01) 445 L/S: Electrical data power 4.0 KW. nr 1 2680.00

3 (FCU-02) 305 L/S: Electrical data power 4.0 KW. nr 1 2277.00

4 (FCU-01) 450 L/S: Electrical data power 4.0 KW. nr 1 2680.00

23 05 93 Testing, adjusting and Balancing for HVAC

5 Air balancing of the ducting network Item 1 INCLUDED

6 Testing, balancing and commissioning of all equipment Item 1 205.00

Supply and install exhaust fan as specified and as indicated in drawing, fan consist of casing, fan, motor, control, filter, sand trap louver, all electrical works (componetns, wiring switches etc;) and all accessories, Electrical power supply 220 / 1 /60

All Items hereunder to be described with information such as type, kind quality, thickness,method of fixing, specified codes of practice,etc, as per the Drawings and Specification)

Supply and install concealed fan coil unit including units as specified and as indicated in drawing, fan consist of casing, fan, motor, control, filter, sand trap louver, all electrical works (componetns, wiring switches etc;) and all accessories, Electrical power supply 220 / 1 /60

All Items hereunder to be described to be of capacity, design, supply, execution,type, kind quality, size, fixing specified codes of practice,etc, as per the Drawings and Specification)

Page 1019: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF

BF

23 00 00 - Heating, Ventilating, and Air Conditioning (HVAC)

Additional Items

1 Marking the position of the holes, mortises and chases in the structure Item 1 INCLUDED

2 Item 1 INCLUDED

3 Testing and commissioning of entire installation Item 1 205.00

4 Preparation of as-built drawings Item 1 818.00

5 Preparation of operation and maintenance manuals Item 1 INCLUDED

Identification: plates,dics labes,tapes, bands, arrows, symbols, letters, numbers and charts: as stated on drawings and in Specification.

Page 1020: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Page 1021: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

AMOUNT FOR HVAC TO SUMMARY US Dollar

26 00 00 - ELECTRICAL

All works hereunder shall be completed as per the Drawings and Specification.

Note

1 Lighting circuits Item 1 997.00

2 Power circuits Item 1 409.00

3 Fire Alarm circuits Item 1 53.00

4 Water heaters circuits Item 1 64.00

5 Fan circuits Item 1 74.00

6 HVAC control circuits Item 1 374.00

26 05 26 Grounding and Bonding for Electrical System

All Items hereunder to be type, kind number of cores, armoring and sheathing, method of fixing, specified codes of practice, etc. as per the Drawings and Specification.

Notwithstanding the provision of the method of measurement, cables have been itemised and referenced to the circuit, the contractor is to make due reference to drawings nr SB-GE-EL001-00, E002-00, E003-00, EL010-01, EL051-00 for full details and is to allow for all cabling, juctions, flexible connections, feeder units etc; required to complete the installation in accordance with the drawings and Specification, No claim for want or lack of knowledge will be entertained.

All Items hereunder to be described with information such as type, kind number of cores, armoring and sheathing, method of fixing, specified codes of practice, etc. as per the Drawings and Specification.

Page 1022: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

7 Grounding system Item 1 2422.00

CF

BF

ELECTRICAL (Cont'd)

26 05 33.13 Conduit for Electrical System

All Items hereunder to be described with information such as type, kind, method of fixing,specified codes of practice ,etc, as per the Drawings and Specification)

Notwithstanding the provision of the method of measurement, cables have been itemised and referenced to the circuit, the contractor is to make due reference to drawings nr SB-GE-EL001-00, E002-00, E003-00, EL010-01, EL051-00 for full details and is to allow for all cabling, juctions, flexible connections, feeder units etc; required to complete the installation in accordance with the drawings and Specification, No claim for want or lack of knowledge will be entertained.

Page 1023: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1 Lighting circuits Item 1 679.00

2 Power circuits Item 1 370.00

3 Fire Alarm circuits Item 1 38.00

4 Water heaters circuits Item 1 45.00

5 Fan circuits Item 1 51.00

6 HVAC control circuits Item 1 402.00

26 24 16 Panel Boards

7 Distribution and Panel boards Item 1 844.00

All Items hereunder to be described with information such as type, kind rated capacity,method of fixing,cores reference to Specification, fuses, background specified codes of practice ,etc, as per the Drawings and Specification)

All Items hereunder to be described with information such as type, kind, rated capacity, method of fixing,cores reference to Specification, fuses, background, specified codes of practice ,etc, as per the Drawings and Specification)

Page 1024: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF

BF

ELECTRICAL (Cont'd)

26 27 13 Electricity Metering

26 27 26 Wiring Devices

Note

Switches & Push Buttons

1 One way one gang switch nr 3 10.00

2 One way one gang switch nr 2 10.00

3 One way two gang switch nr 3 12.00

Power Outlets

4 Double outlet nr 11 19.00

5 Double outlet in and including floor box, allow for forming sinking in slab/screed nr 3 210.00

6 Duplex receptacle outlet, 230V, 20A connectedto emergency power supply nr 3 19.00

All Items hereunder to be described with information such as type, kind rated capacity,method of fixing,cores reference to Specification, fuses, background specified codes of practice ,etc, as per the Drawings and Specification)

Notwithstanding the provision of the method of measurement, wiring devices shall include final circuits, No claim for lack or want of knoledge shall be entertained.

All Items hereunder to be described with information such as appropriate to the procurement , type, kind quality, size method of fixing, specified codes of practice,etc, as per the Drawings and Specification)

Page 1025: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

7 1 way 20A 2P 230V switch with pilot light nr 2 16.00

26 50 00 Lighting

8 nr 7 1471.00

9 nr 19 157.00

10 nr 3 114.00

11 nr 2 147.00

CF

BF

ELECTRICAL (Cont'd)

Additional Items

Notwithstanding the provision of the method of measurement, lighting shall include final circuits, No claim for lack or want of knoledge shall be entertained.

All Items hereunder to be described with information such as appropriate to the procurement , type, kind quality, size method of fixing, specified codes of practice,etc, as per the Drawings and Specification)

All Items hereunder to be described with information such as appropriate to the procurement , type, kind quality, size method of fixing, specified codes of practice,etc, as per the Drawings and Specification)

Luminaire wall mounted bulkhead outdoor landscape clear with a 100W mercury vapour elliptical lamp, prismatic pattern moulded polycarbonate diffuser cover; type BH2

Luminaire surface mounted industrial flourescent with wrap disffuser cover, 2 x 36W TB lamps; type LH2

Luminaires, down light, reccessed mounting 2 x 36W CFL; compact lamp 220V, 60Hz; type G1

Luminaire, direct wall mounted emergency exit sign with battery back up: type EX

Page 1026: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1 Marking the position of holes, mortises and chases in the structure Item 1 0.00

2 Item 1 0.00

3 Testing and commissioning and maintenance manuals Item 1 0.00

4 Preparation of as-built drawings Item 1 0.00

5 Preparation of maintanance manuals Item 1 0.00

26 00 00 - ELECTRICAL

6

6.1 Double outlet WP nr 1 58.00

6.2 Double outlet HD nr 1 19.00

6.3 Disconnect switch ,NEMA-4X nr 3 691.00

6.4 Two way one gang switch nr 2 7.00

6.5 Two way two gang switch nr 2 10.00

6.6 GATE BARRIER POWER SUPPLY nr 1 164.00

Identification; plates, dics, labels, tapes, bands, arrows; symbols, letters, numbers and charts; as stated on drawings and in Specification.

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Page 1027: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

AMOUNT FOR ELECTRICAL TO SUMMARY US Dollar

27 00 00 COMMUNICATIONS

Telecommunication / Low Current

STRUCTURED CABLING SYSTEM

1 Information Outlet, Flush Type 1 DATA 1 Telephone 0.3 Meters A.F.F.L nr 2 47.00

2 Telephone outlet, wall mounted, Flush Type 1.2 Meters A.F.F.L nr 1 34.00

3 Information Outlet, Floor mounted 1 data, 1 telephone nr 4 47.00

4 9U Telecom Cabinet, Wall mounted nr 1 1962.00

5 CAT 6A UTP Cable nr 252 8.00

6 Single Mode Fibre Optic Cable - 1 x 12 Core nr 250 10.00

Supply , Install Test, connect and commission inclusive of all cabling, conduits and containment, socket outlets, all in accordance with the relevant service provider regulations, rules, recommendation and requirements and in accordance with the specifications and drawings.

Page 1028: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

IP CCTV

7 P and T CCTV Camera nr 3 1505.00

8 IP Fixed type CCTV wall mounted Outdoor Camera nr 1 1505.00

9 IP Fixed type high Resolution Outdoor Camera (Plate Number Reader ) nr 4 4168.00

10 CAT 6A UTP Cable m 100 8.00

CF

BF

COMMUNICATION (Cont'd)

Parking Control System / Gate Barrier

Supply, install, test, connect and commission inclusive of all cabling, conduits and containment, socket outlet, all in accordance with the relevant sevice provider regulations, rules, recommendation and requirements and in accordance with the specifications and drawings.

Page 1029: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1 Card reader for Gate barrier nr 2 547.00

2 RFID reader nr 2 547.00

3 Gate barrier Control Panel nr 2 2750.00

4 Loop detector nr 4 929.00

5 Photo electric Cells nr 4 included in the above

6 Gate barrier and Arm nr 2 5315.00

7 Push button for Gate barrier nr 2 190.00

Fire Alarm System

8 Addressable, Smoke Detector nr 3 68.00

9 Addressable, Manual Pull Station nr 2 68.00

10 Sounder / Fire Alarm Bell / Horn nr 3 80.00

11 Fault Isolator nr 1 76.00

12 Control Module nr 1 68.00

13 Fire Alarm Control Panel nr 1 3047.00

14 Power Supply Unit, 24V nr 1 included in the above

15 Loop Cable, 2 x 1.5mm2 Fire Resistant nr 70 9.00

16 24V Cable, 2 x 2.5mm2 Fire Resistant nr 52 9.00

Supply, install, test, connect and commission inclusive of all cabling, conduits and containment, socket outlet, all in accordance with the relevant sevice provider regulations, rules, recommendation and requirements and in accordance with the specifications and drawings.

Supply, install, connection testing and commissioning of wiring and equipment for Fire Alarm System including all necessary material's and accessories to reflect complete system installation.

Page 1030: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF

BF

Access Control System

1 Card Reader nr 3 232.00

2 Push Button nr 3 306.00

3 Emergency Break Glass nr 3 134.00

4 Electromagnetic Door Lath nr 3 380.00

5 Control Panel nr 3 1739.00

6 Magnetic Door Contact Swicth nr 3 220.00

Additional Items

7 Marking the position of holes, mortises and chases in the structure Item 1 0.00

8 Item 1 0.00

Supply, install, connection testing and commissioning of wiring and equipment for Fire Alarm System including all necessary material's and accessories to reflect complete system installation.

Identification; plates, dics, labels, tapes, bands, arrows; symbols, letters, numbers and charts; as stated on drawings and in Specification.

Page 1031: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

9 Testing and commissioning and maintenance manuals Item 1 0.00

10 Preparation of as-built drawings Item 1 0.00

11 Preparation of maintanance manuals Item 1 0.00

12

ADDITIONAL

12.1 Fire Alarm Repeater Panel with Workstation nr 1 16460.00

12.2 CCTV Equipment Item 1 7452.00

12.03 ADDITIONAL (As per Q&A 487)

ACTIVE COMPONENTS (AS PER Q&A 487) DISTRIBUTION CABINETnr 1

4609.00

AMOUNT FOR COMMUNICATION TO SUMMARY US Dollar

31 00 00 EARTHWORK

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Page 1032: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

31 10 00 Site Clearing

1 Site preparation, clearing site vegetation 115 2.00

31 23 16 Excavation

2 Excavation top soil for preservation, average depth 150mm m³ 115 3.00

3 Excavating pits, depth of excavation not exceeding 2 m m³ 82 8.00

4 Excavating trenches for grade beams; width ≤ 0.3m m³ 8 10.00

31 23 16 Backfill

5 m³ 69 12.00

31 23 23.23 Compaction

6 m² 115 3.00

31 23 16.26 Rock Removal

7 Disposal of excavated material, off site as stated in the Specification. m³ 21 4.00

31 31 16 Termite Control

All works herein shall be comnpleted in full compliance with the Drawings nr SB-GH-S001, S002, S003, S004, S005 and Specification.

m3

Filling to excavations, average thickness > 0.25 m, arising from excavated materials, all fill shall be compacted to 75% relative density for cohesion-less soils as per ASTM D4254/ASTM D4293 or 95% maximum density as determined by ASTM D698 for cohesive material, as per the Drawings and Specifications).

Surface treatments, compacting bottom of excavation, compaction to meet 85% of relative density for cohesion-less soils or 95% maximum density as determined by ASTM D1557 for cohesive materials per the Drawings and Specifications)

Page 1033: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

8 m² 45 1.00

9 m² 132 0.00

CF

BF

31 00 00 EARTHWORK

Additional Items

1

Termite control for the horizontal surface (method and type of treatment as per the Drawings and Specifications)

Termite control for the vertical surface (method and type of treatment as per the Drawings and Specifications)

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included.

Page 1034: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836
Page 1035: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

AMOUNT FOR EARTH WORKS TO SUMMARY US Dollar

32 31 36 SECURITY FENCES, GATES AND BARRIERS

want of knowledge will be entertained.

1 Security fencing and gates all as drawing GH-A905 and Specification nr 1 84109.00

2 nr 2 7560.00

All work to be carried out in accordance with drawing Nr GH-A905 and Specification

Notwithstanding the provisions of the Method of Measurement, fencing and gates have

been measured as an item based on the drawing. The Contractor is to include for all

excavation, concrete, supply and fitting of gates and fencing including tracks, electrical

controls, wiring, motors etc. and all works to complete the gates. No claim for lack or

rising barrier all as drawing Nr GH-A905 and specification including all excavation, disposal concrete, electrics, motors, controls and all works to complete

Page 1036: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

AMOUNT FOR SECURITY FENCES, GATES AND BARRIERS TO SUMMARY US Dollar

03 00 00 Concrete

04 00 00 Masonry

05 00 00 Metal

06 00 00 Wood, plastic and composites

07 00 00 Thermal and Moisture Protection

08 00 00 Openings

09 00 00 Finishes

10 00 00 Specialties

Page 1037: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

11 00 00 Equipment

12 20 00 Furnishing

22 00 00 Plumbing

23 00 00 Heating, Ventilating and Air Conditioning ( HVAC )

26 00 00 Electrical

27 00 00 Communications

31 00 00 Earthwork

32 00 00 Security fences, gates and barriers

SUBTOTAL

MULTIPY BY 1 NR BLOCKS 1

SUBTOTAL

Page 1038: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

TOTAL FOR MAIN ENTRANCE GUARD HOUSE TO SUMMARY US Dollar

TYPICAL ENTRY/ EXIT GUARD HOUSE

03 00 00 - CONCRETE

1 m³ 7 188.00

03 31 00 Structural Concrete

2 m³ 16 442.00

3 m³ 7 698.00

Notwithstanding the Provisions of the Standard Method of Measurement of Building Works Seventh Edition, 1988 (SMM7) the following,concrete works are measured m³/m including. reinforcement bars and formworks. The Contractor is to include for cost of reinforcement and formwork with concrete works. No additional charge or cost for reinforcement and formwork separately will be entertained due to lack or want of knowledge.

All concrete works herein shall be completed in full compliance with the Drawings and Specification.

Plain Concrete 20 Mpa, for blinding Beds, Thickness ≤ 150mm, poured against the compacted soil, as stated in the Structural Notes and Specification.

Reinforced concrete 35 MPa, foundations (footings), (kind, quality, curing details etc. as stated in the Structural Notes and Specification.

Reinforced concrete 35 MPa for ground beams, (footings), (kind, quality, curing details etc. as stated in the Structural Notes and Specification.

Page 1039: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

4 m³ 10 391.00

5 m³ 1 705.00

6 m³ 2 805.00

7 m³ 18 804.00

Reinforced concrete beds 35 MPa for slab with A393 welded wire mesh, on grade thickness ≤ 150mm, poured against the compacted soil (kind, quality, curing details etc. as stated in the Structural Notes and Specification.

Reinforced concrete for substructure columns 35 MPa up to slab on grade, (kind, quality curing details etc. as stated in the Structural Notes and Specification.

Reinforced concrete 35 MPa for superstructure slabs, thickness 150mm, (kind, quality curing details etc. as stated in the Structural Notes and Specification.

Reinforced concrete parapet wall at roof, 200mm thick, vertical, (kind, quality, type of bond, mix of mortar etc. to be included as per the Specification)

Page 1040: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF

BF

CONCRETE (Cont'd)

1 m³ 13 666.00

2 m³ 5 1000.00

03 41 16 Precast Concrete Slabs

3 m² 87 115.00

03 30 53 - Miscellaneous Cast-in-situ Concrete

4 200mm wide x 200mm high reinforced concrete 35 Mpa for lintel m 13 21.00

03 53 00 Concrete Topping

5 m² 69 17.00

Reinforced concrete 35 MPa superstructure beams, (kind, quality, curing details etc. as stated in the Structural Notes and Specification.

Reinforced concrete 35 MPa superstructure columns, (kind, quality, curing details etc. as stated in the Structural Notes and Specification

Precast concrete hollow core slab 35 MPa for superstructure slabs, thickness 350mm (kind, quality, fixing, connection, including neoprene bearing pad and details etc. as stated in the Structural Notes and Specification.

Sand cement/concrete screed for floors, width > 300mm, (thickness,kind quality,composition mix, nature of base method of construction. Layout and treatments,thermal insulation,moisture resistant treatment method of jointing, etc, as per the Drawings and Specification).

Page 1041: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

6 m² 76 44.00

03 00 00 - Concrete

Additional Items

Structure screed concrete on roof, width > 300mm, (thickness,kind quality,composition mix, nature of base method of construction. Layout and treatments,thermal insulation,moisture resistant treatment method of jointing, etc, as per the Drawings and Specification).

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included

Page 1042: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

AMOUNT FOR CONCRETE TO SUMMARY US Dollar

04 00 00 - Masonry

External walls

1 m² 41 83.00

04 00 00 - Masonry

Additional Items

All Masonry works herein shall be completed full incompliance with the Drawings and Specification.

300mm thick CMU wall, vertical, comprised with 150mm block work external side, 50mm insulation, 100mm block work internal side, (kind, quality and size of blocks, type of bond, mix of mortar etc. to be included as per the details and Specification )

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included

Page 1043: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

AMOUNT FOR MASONRY TO SUMMARY US Dollar

07 00 00 THERMAL AND MOISTURE PROTECTION

07 10 00 Damp proofing and Waterproofing

Substructure Waterproofing

1 m² 80 5.00

2 m² 40 5.00

All works herein shall be completed in full incompliance with the Drawings and Specification.

Waterproofing works for substructure with two coats of bitumen paint, vertical surface as per the Drawings and Specification).

Waterproofing works for substructure with two coats of bitumen paint, horizontal surface, s as per the Drawings and Specification).

Page 1044: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3 m² 133 2.00

4 m² 76 39.00

5 m² 76 23.00

07 00 00 Thermal and Moisture Protection

Additional Items

6

Waterproofing works for substructure with vapour barrier 250 microns, horizontal surface, as per the Drawings and Specification).

All works herein shall be completed in full compliance with the Drawings and Specification.

Waterproofing membrane for roof, horizontal surface, as per the Drawings and Specification)

100mm thick insulation for water proofing works at roof, horizontal surface, as per the Drawings and Specification)

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included

Page 1045: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

AMOUNT FOR THERMAL AND MOISTURE PROTECTION TO SUMMARY US Dollar

08 00 00 OPENINGS

Note

08 11 13 Metal Doors and Frames

1 nr 1 2935.00

08 51 13 Aluminum Windows

All works herein shall be completed in full compliance with the Doors & Windows Schedule Drawings and Specification.

Note: Notwithstanding the Provisions of the Standard Method of Measurement, door sets including doors, frames, vision panels, decoration and ironmongery have been measured as a composite item and the Contractor should make due reference to the drawings and specification. No claim for lack or want of knowledge will be entertained

Supply and fix glazed steel door, 45mm thick, 1000mm wide x 2200mm high including steel frame, type D1; 6mm Georgian wired tinted glass panel, 700mm x 1350mm fixed with steel glazing beads finished with and including paint, all accessories and hardware including but not limited to hinges HDH type, MO closer, inside lock, lever handles and latch, wall stop, roses and escutcheons as stated in the Specification

Page 1046: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2 nr 1 8536.00

3 nr 1 2846.00

08 00 00 Openings

Additional Items

Supply and fix aluminum double glazed window (glazing to be ballistic resistant, burglary resistant and blast resistant), 4500mm wide x 1200mm high, fixed light including frame type W7, powder coated finish, all accessories and hardware including but not limited to handle, lock, weather tight strip etc. as stated in the Drawings and Specification.

Supply and fix aluminum double glazed window (glazing to be ballistic resistant, burglary resistant and blast resistant), 1500mm wide x 1200mm high, fixed light including frame type W8, powder coated finish, all accessories and hardware including but not limited to handle, lock, weather tight strip etc. as stated in the Drawings and Specification.

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included

Page 1047: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

AMOUNT FOR OPENINGS TO SUMMARY US Dollar

09 00 00 - FINISHES

09 23 00 Gypsum Plastering

1 m² 95 0.00

09 24 00 Cement Plastering

2 m² 21 22.00

All works herein shall be completed full incompliance with the schedule Drawings and Specification.

Note: Notwithstanding the Provisions of the Standard Method of Measurement, corner and stop beads are deemed to be included with plastering. The Contractor is to make all due allowance for these items and no claim for want or lack of information will be entertained.

Gypsum plastering for ceiling to receive paint finish, width > 300mm, (thickness, kind, quality, composition, mix materials, nature of base, method of construction, layout and treatments, thermal insulation, moisture resistant treatment, method of jointing and joint reinforcement, etc. as per the Drawings nr GH-A901 and Specification).

Plastering for walls to receive paint finish, width > 300mm, (thickness, kind, , mix materials, nature of base, method of construction, layout and treatments, thermal insulation, moisture resistant treatment, method of jointing, etc. as per the Drawings GH A901 and Specification).

Page 1048: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3 m² 36 29.00

4 m² 91 29.00

09 30 13 Ceramic Tiling

Floor Tiling

5 m² 83 51.00

Self coloured rendering (pre coloured mineral wall coating) for walls, External, width > 300mm, (thickness, kind, , mix materials, nature of base, method of construction, layout and treatments, thermal insulation, moisture resistant treatment, method of jointing, etc. as per the Drawings nr GH-A202, GH-A901 and Specification).

Self coloured rendering (pre coloured mineral wall coating) for parapet walls, roof area width > 300mm, (thickness, kind, , mix materials, nature of base, method of construction width > 300mm, (thickness, kind, , mix materials, nature of base, method of construction jointing, etc. as per the Drawings nr GH-A502, GH-A901 and Specification).

Porcelain tile flooring, guard office and waiting area (type - FT7), 600mm x 600mm, level or to falls only ≤ 15° from horizontal, fixed over cement sand screed (screed measured separately) selected colour, thickness, method of construction, layout and treatments, method of jointing, etc. as per the Drawings nr GH-A202,502,702,901 and Specification.

Page 1049: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF

BF

FINISHES (cont'd)

Skirting

1 m 11 19.00

09 50 00 Ceilings

2 m² 95 54.00

09 91 00 - Painting

Floor Painting

3 nr 2 121.00

Wall -Painting

MDF skirting 150mm height, vertical, fixed over cement sand plaster (thickness, kind quality, size, method of construction, layout and treatments, moisture resistant treatment, method of jointing, etc. as per the Drawings and Specification).

Supply and install gypsum ceiling, depth of suspension 500 - 1000 mm (thickness of lining and method of fixing system to structure, kind, quality, size, nature of backgrounds insulation materials etc. as per the Drawings nr GH-A202,502,702,901 and Specification.

Painting for floor, white reflectorized traffic paint girth > 300mm, (kind, quality of materials, painted on cement plastering, preparatory works, priming coat, undercoats, finishing coat method of application, etc. as per the Drawings and Specification).

Page 1050: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

4 m² 21 11.00

Ceiling -Painting

5 m² 95 11.00

Additional Items

AMOUNT FOR FINISHES TO SUMMARY US Dollar

10 00 00 SPECIALTIES

10 44 13.13 Portable Fire Extinguishers

Painting for internal walls, girth > 300mm, (kind, quality of materials, painted on cement plastering, preparatory works, priming coat, undercoats, finishing coat method of application, etc. as per the Drawings and Specification).

Painting for ceiling, girth ≤ 300mm, (kind, quality of materials, painted on cement plastering , preparatory works, priming coat (1nr), undercoats (1nr), finishing coat (1nr), method of application, etc. as per the Drawings and Specification).

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included

All items hereunder to be described with kind, quality, size, method of fixing , etc. as per the Drawings and Specification).

Page 1051: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1 Supply & install Portable Fire Extinguishers nr 1 54.00

2 Supply and emergency Fire blanket nr 1 76.00

10 00 00 Specialties

Additional Items

AMOUNT FOR SPECIALTIES TO SUMMARY US Dollar

22 00 00 - PLUMBING

22 13 19.13 Sanitary Drains

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included

All items hereunder to be describes specified code of practice and regulation, (kind, quality,size, method of fixing , finishes or surface treatments, etc. as per the Drawings and Specification).

Page 1052: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Rain water Pipe

1 75 mm diameter. m 10 17.00

Condensate Drain Pipe Works

2 20 mm diameter. m 5 9.00

22 40 00 Plumbing Fixtures

3 Roof drain; 75 mm diameter nr 2 171.00

22 00 00 - Plumbing

Additional Items

4 Marking the position of holes, mortises and chases in the structure Item 1 included

5 Item 1 included

6 Testing and commissioning and maintenance manuals Item 1 included

7 Preparation of as-built drawings Item 1 included

8 Preparation of maintanance manuals Item 1 included

Sanitary drains (to include rainwater pipework and condensate drain pipework) are classified by material and diameter. Rates include furnishing and installing of pipes, fittings, accessories, fixing supports, joints, sleeves, special parts, connections, hanger supports. Rates also include testing of pipes at the manufacturer's premises. All as per the Drawings and specification.

All items described hereunder to be of kind, quality, size, nature of base, method of fixing, complete with accessories etc. as per the Drawings and Specification

Identification; plates, dics, labels, tapes, bands, arrows; symbols, letters, numbers and charts; as stated on drawings and in Specification.

Page 1053: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

AMOUNT FOR PLUMBING TO SUMMARY US Dollar

23 00 00 - HEATING, VENTILATING, AND AIR CONDITIONING (HVAC)

All HVAC works shall be completed as per the Drawings and Specification.

23 82 00 Convection Heating and Cooling Units

1 nr 1 2072.00

All items described hereunder to be of capacity, design, supply, execution, type, kind, quality, size, method of fixing , specified codes of practice, etc. as per the Drawings and Specification.

Supply and install, test and commission concealed fan coil unit as specified and as indicated in drawing. Unit to be complete with air cooled condensing unit, fan, filter, valves, controls, thermostat, all electrical works (components, wiring, switches etc.) and all accessories. Electrical power supply 220/1/60.

(FCU-01), 175 L/s; Electrical data power 3.0 KW, 220/1/60 total load 2.1Kw, sensible load 2.0, heating load 0.6 kw, hi-wall decorative type.

Page 1054: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

23 00 00 - Heating, Ventilating, and Air Conditioning (HVAC)

Additional Items

2 The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included

Page 1055: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

AMOUNT FOR PLUMBING TO SUMMARY US Dollar

26 00 00 - ELECTRICAL

All works hereunder shall be completed as per the Drawings and Specification.

26 05 19 Low Voltage Electrical Power Conductors and cables

Note

1 Lighting circuits Item 1 522.00

2 Power circuits Item 1 86.00

26 05 26 Grounding and Bonding for Electrical Systems

All items hereunder to be of type, kind, number of cores, armouring and sheathings method of fixing , specified codes of practice, etc. as per the Drawings and Specification).

Notwithstanding the Provisions of the method of measurement, cables have been itemized and referenced to the circuit. The contractor is to make due reference to drawings nrs SB-GE-EL001-00,EL002-00,EL003-00,EL010-01,EL051-00,TE801-00 for full details and is to allow for all cabling, junctions, flexible connections, feeder units etc. required to complete the installation in accordance with the drawings and Specification No claim for want or lack of knowledge will be entertained.

All items hereunder to be described with information such as type, kind, number of cores, armouring and sheathings, method of fixing , specified codes of practice, etc. as per the Drawings and Specification).

Page 1056: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3 grounding system Item 1 2422.00

26 05 33.13 Conduit for Electrical Systems

All items hereunder to be described with information such as type, kind, , method of fixing , specified codes of practice, etc. as per the Drawings and Specification).

Notwithstanding the Provisions of the method of measurement, cables have been itemized and referenced to the circuit. The contractor is to make due reference to drawings nrs SB-GE-EL001-00,EL002-00,EL003-00,EL010-01,EL051-00,TE801-00 for full details and is to allow for all cabling, junctions, flexible connections, feeder units etc. required to complete the installation in accordance with the drawings and Specification No claim for want or lack of knowledge will be entertained.

Page 1057: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF

BF

ELECTRICAL (cont'd)

1 Lighting circuits Item 1 356.00

2 Power circuits Item 1 78.00

26 24 13 Switchboards

3 Item 1 0.00

4 Distribution and panel boards Item 1 756.00

26 27 13 Electricity Metering

5 Item 1 0.00

26 27 26 Wiring Devices

Note

Switches & Push Buttons

6 One way two gang switch nr 1 10.00

7 One way three gang switch nr 1 20.00

All items hereunder to be described with information such as type, kind, rated capacity, method of fixing, cores reference to Specification, fuses, codes of practice, etc. as per the Drawings and Specification).

All items hereunder to be described with information such as type, kind, rated capacity, method of fixing, cores reference to Specification, fuses, codes of practice, etc. as per the Drawings and Specification).

Notwithstanding the Provisions of the Method of Measurement, wiring devices shall include final circuits. No claim for lack or want of knowledge shall be entertained

All items hereunder to be described with information such as appropriate to the procurement , type, kind, quality, size, method of fixing , specified codes of practice, etc. as per the Drawings and Specification).

Page 1058: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF

BF

ELECTRICAL (cont'd)

Power Outlets

1 Double receptacle outlet, 230V, 20A normal power supply nr 4 19.00

2 Disconnection switch, NEMA-4X nr 1 691.00

26 50 00 Lighting

Note

3 nr 2 1471.00

4 nr 2 157.00

5 nr 12 369.00

6 nr 4 248.00

Notwithstanding the Provisions of the Method of Measurement, lighting shall include final circuits. No claim for lack or want of knowledge shall be entertained

All items hereunder to be described with information such as appropriate to the procurement , type, kind, quality, size, method of fixing , specified codes of practice, etc. as per the Drawings and Specification).

Wall mounted bulkhead outdoor landscape clear with a 100W,220V/60Hz mercury vapour elliptical lamp, prismatic pattern moulded polycarbonate diffuser cover of IP-65; type BH2

Surface mounted industrial fluorescent luminaire with wrap diffuser cover, installed with 2 x 36W T8 fluorescent lamps for conventional control gears; type LH2

Surface mounted IP-65 industrial fluorescent luminaire with symmetrical reflector installed with 2 x 36W T8 fluorescent lamps; type LM01

Bracket mounted asymmetrical flood light with100W metal halide lamps for conventional control gears; type FL03

Page 1059: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Additional Items

7 Marking the position of holes, mortises and chases in the structure Item 1 0.00

8 Item 1 0.00

9 Testing and commissioning of entire installation Item 1 0.00

10 Preparation of as-built drawings Item 1 0.00

11 Preparation of operation and maintanance manuals Item 1 0.00

CF

BF

ELECTRICAL (cont'd)

Identification; plates, dics, labels, tapes, bands, arrows; symbols, letters, numbers and charts; as stated on drawings and in Specification.

Page 1060: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included

Page 1061: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

AMOUNT FOR ELECTRICAL TO SUMMARY US Dollar

27 00 00 COMMUNICATIONS

27 00 00 COMMUNICATIONS

STRUCTURED CABLING SYSTEM

1 Telephone Outlet, Wall Mounted, Flush Type nr 1 30.00

2 Fibre converter nr 1 0.00

IP CCTV

Supply, Install, Test, connect and commission inclusive of all cabling, conduits and containment, socket outlets, all in accordance with the relevant service provider regulations , rules, recommendation and requirements and in accordance with the specifications and drawings.

Supply, Install, Test, connect and commission inclusive of all cabling, conduits and containment, socket outlets, all in accordance with the relevant service provider regulations , rules, recommendation and requirements and in accordance with the specifications and drawings.

Page 1062: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3 IP Fixed type High Resolution Outdoor Camera (Plate Number Reader) nr 2 4168.00

4 CAT 6A, UTP Cable m 15 7.00

Parking Control System / Gate Barrier

5 Gate Barrier Control Panel nr 1 2750.00

6 Gate Barrier and Arm nr 1 5315.00

7 Push Button for Gate Barrier nr 1 190.00

Supply, Install, Test, connect and commission inclusive of all cabling, conduits and containment, socket outlets, all in accordance with the relevant service provider regulations , rules, recommendation and requirements and in accordance with the specifications and drawings.

Page 1063: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF

BF

Additional Items

1 Marking the position of holes, mortises and chases in the structure Item 1 included

2 Item 1 included

3 Testing and commissioning of entire installation Item 1 included

4 Preparation of as-built drawings Item 1 included

5 Preparation of operation and maintanance manuals Item 1 included

Additional Items

Identification; plates, dics, labels, tapes, bands, arrows; symbols, letters, numbers and charts; as stated on drawings and in Specification.

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included

Page 1064: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

AMOUNT FOR COMMUNICATION TO SUMMARY US Dollar

31 00 00 EARTHWORK

31 10 00 Site Clearing

1 Site preparation, clearing site vegetation m² 95 2.00

31 23 16 Excavation

2 Excavation top soil for preservation, average depth 150mm m² 95 3.00

3 Excavating pits(9 nr), maximum depth ≤ 2.00m. m³ 88 8.00

All works herein shall be completed in full compliance with the Drawings nr V-S001,VS002 V-S003,V-S004,V-S005,V-S401and Specification.

Page 1065: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

4 Excavating trenches for grade beams, width ≤ 0.3m m³ 7 10.00

31 23 23.13 Backfill

5 m³ 65 12.00

31 23 23.23 Compaction

6 m² 85 3.00

31 23 16.26 Rock Removal

7 Disposal of excavated material, off site as stated in the Specification. m³ 30 4.00

31 31 16 Termite Control

8 m² 50 1.00

9 m² 160 0.00

Filling to excavation, average thickness > 0.25 m, arising from excavated materials, all fill shall be compacted to 75% relative density for cohesion-less soils as per ASTM D4254/ASTM D4293 or 95% maximum density as determined by ASTM D698 for cohesive material, as per the Drawings and Specifications).

Surface treatment, compacting bottom of excavation, compaction to meet 85% of relative density for cohesion-less or 95% maximum density as determined by ASTM D1557 for cohesive materials per the Drawings and Specification).

Termite control for the horizontal surface (method and type of treatment as per the Drawings and Specifications)

Termite control for vertical surface (method and type of treatment as per the Drawings and Specifications)

Page 1066: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

AMOUNT FOR EARTHWORK TO SUMMARY US Dollar

Additional Items

32 31 36 SECURITY FENCES, GATES AND BARRIERS

1 nr 2 7560.00

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included

All work to be carried out in accordance with drawing Nr GH-A202 and Specification

Notwithstanding the provisions of the Method of Measurement, fencing and gates have been measured as an item based on the drawing. The Contractor is to include for all excavation, concrete, supply and fitting of gates and fencing including tracks, electrical controls, wiring, motors etc. and all works to complete the gates. No claim for lack or want of knowledge will be entertained.

rising barrier all as drawing Nr GH-A202 and specification including all excavation, disposal concrete, electrics, motors, controls and all works to complete.

Page 1067: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

AMOUNT FOR SECURITY FENCES AND GATES TO SUMMARY US Dollar

03 00 00 Concrete

Page 1068: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

04 00 00 Masonry

07 00 00 Thermal and Moisture Protection

08 00 00 Openings

09 00 00 Finishes

10 00 00 Specialties

22 00 00 Plumbing

23 00 00 Heating, Ventilating and Air Conditioning ( HVAC )

26 00 00 Electrical

27 00 00 Communications

31 00 00 Earthwork

32 00 00 Security fences, gates

SUBTOTAL

Page 1069: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

TOTAL FOR ENTY/EXIT GUARD HOUSE TO SUMMARY US Dollar

Main Entrance Guard House

Typical Entry/ Exit Guard House

AMOUNT FOR SECURITY BUILDINGS TO SUMMARY US Dollar

Page 1070: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Amount

940.00

6,030.00

5,328.00

4,644.00

Page 1071: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1,368.00

7,368.00

11,448.00

3,352.00

40,478.00

40,478.00

11,280.00

Page 1072: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

8,295.00

3,153.00

1,176.00

616.00

1,360.00

1,360.00

0.00

Page 1073: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

67,718.00

1,156.00

Page 1074: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

20,430.00

4,646.07

Page 1075: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

26,232.07

2,646.00

Page 1076: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2,646.00

5,420.00

Page 1077: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3,388.00

299.00

514.00

670.00

432.00

1,517.00

Page 1078: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

12,240.00

530.00

190.00

278.00

Page 1079: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

264.00

88.00

2,960.00

240.00

1,840.00

6,390.00

6,390.00

Page 1080: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

5,030.00

Page 1081: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

11,420.00

Page 1082: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

5,870.00

1,576.00

952.00

2,385.00

Page 1083: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

10,783.00

10,783.00

18,816.00

16,128.00

Page 1084: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

10,752.00

6,860.00

2,688.00

271.00

Page 1085: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

66,298.00

66,298.00

82.00

Page 1086: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

66,380.00

0.00

0.00

Page 1087: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

7,150.00

2,156.00

420.00

8,178.00

Page 1088: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

17,904.00

17,904.00

1,769.00

5,151.00

204.00

Page 1089: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2,560.00

1,344.00

782.00

Page 1090: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

29,714.00

29,714.00

528.00

494.00

5,454.00

224.00

3,575.00

Page 1091: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1,078.00

41,067.00

41,067.00

1,111.00

44.00

Page 1092: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

444.00

380.00

531.24

Page 1093: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

43,577.24

21.00

22.00

17.00

54.00

Page 1094: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

114.00

Page 1095: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

0.00

Page 1096: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2,533.00

0.00

Page 1097: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2,533.00

Page 1098: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

20.00

65.00

included in sanitary fixtures section 224000

38.00

366.00

225.00

80.00

80.00

1,618.00

45.00

96.00

96.00

Page 1099: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2,729.00

2,729.00

33.00

145.00

81.00

Page 1100: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

136.00

108.00

3,232.00

3,232.00

Page 1101: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

255.00

135.00

482.00

192.00

38.00

313.00

202.00

171.00

43.00

171.00

166.00

Page 1102: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

5,400.00

5,400.00

636.00

202.00

458.00

205.00

205.00

818.00

Page 1103: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

7,924.00

198.00

Page 1104: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

198.00

198.00

Page 1105: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

133.00

2,680.00

2,277.00

2,680.00

205.00

Page 1106: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

8,173.00

8,173.00

205.00

818.00

Page 1107: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836
Page 1108: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

9,196.00

997.00

409.00

53.00

64.00

74.00

374.00

Page 1109: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2,422.00

4,393.00

4,393.00

Page 1110: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

679.00

370.00

38.00

45.00

51.00

402.00

844.00

Page 1111: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

6,822.00

6,822.00

30.00

20.00

36.00

209.00

630.00

57.00

Page 1112: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

32.00

10,297.00

2,983.00

342.00

294.00

21,752.00

21,752.00

Page 1113: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

0.00

0.00

0.00

0.00

0.00

58.00

19.00

2,073.00

14.00

20.00

164.00

Page 1114: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

24,100.00

94.00

34.00

188.00

1,962.00

2,016.00

2,500.00

Page 1115: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

4,515.00

1,505.00

16,672.00

800.00

30,286.00

30,286.00

Page 1116: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1,094.00

1,094.00

5,500.00

3,716.00

included in the above

10,630.00

380.00

204.00

136.00

240.00

76.00

68.00

3,047.00

included in the above

630.00

468.00

Page 1117: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

57,569.00

57,569.00

696.00

918.00

402.00

1,140.00

5,217.00

660.00

0.00

0.00

Page 1118: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

0.00

0.00

0.00

16,460.00

7,452.00

4,609.00

95,123.00

Page 1119: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

230.00

345.00

656.00

80.00

828.00

345.00

84.00

Page 1120: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

45.00

0.00

2,613.00

2,613.00

Page 1121: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836
Page 1122: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2,613.00

84,109.00

15,120.00

Page 1123: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

99,229.00

67,718.00

26,232.07

2,646.00

12,240.00

11,420.00

66,380.00

43,577.24

114.00

Page 1124: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

0.00

2,533.00

7,924.00

9,196.00

24,100.00

95,123.00

2,613.00

99,229.00

471,045.31

471,045.31

Page 1125: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

471,045.31

1,316.00

7,072.00

4,886.00

Page 1126: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3,910.00

705.00

1,610.00

14,472.00

Page 1127: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

33,971.00

33,971.00

8,658.00

5,000.00

10,005.00

273.00

1,173.00

Page 1128: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3,344.00

Page 1129: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

62,424.00

3,403.00

Page 1130: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3,403.00

400.00

200.00

Page 1131: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

266.00

2,964.00

1,748.00

Page 1132: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

5,578.00

2,935.00

Page 1133: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

8,536.00

2,846.00

Page 1134: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

14,317.00

0.00

462.00

Page 1135: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1,044.00

2,639.00

4,233.00

Page 1136: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

8,378.00

8,378.00

209.00

5,130.00

242.00

Page 1137: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

231.00

1,045.00

15,235.00

Page 1138: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

54.00

76.00

130.00

Page 1139: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

170.00

45.00

342.00

Page 1140: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

557.00

2,072.00

Page 1141: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836
Page 1142: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2,072.00

522.00

86.00

Page 1143: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2,422.00

Page 1144: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3,030.00

3,030.00

356.00

78.00

0.00

756.00

0.00

10.00

20.00

Page 1145: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

4,250.00

4,250.00

76.00

691.00

2,942.00

314.00

4,428.00

992.00

Page 1146: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

0.00

0.00

0.00

0.00

0.00

13,693.00

13,693.00

Page 1147: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836
Page 1148: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

13,693.00

30.00

0.00

Page 1149: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

8,336.00

105.00

2,750.00

5,315.00

190.00

Page 1150: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

16,726.00

16,726.00

Page 1151: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

16,726.00

190.00

285.00

704.00

Page 1152: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

70.00

780.00

255.00

120.00

50.00

0.00

Page 1153: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2,454.00

15,120.00

Page 1154: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

15,120.00

62,424.00

Page 1155: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3,403.00

5,578.00

14,317.00

15,235.00

130.00

557.00

2,072.00

13,693.00

16,726.00

2,454.00

15,120.00

151,709.00

Page 1156: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

151,709.00

471,045.31

151,709.00

622,754.31

Page 1157: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Item Nr. Description Unit Qty Rate Amount

MV SWITCHGEAR ROOM (ES)

03 00 00 - CONCRETE

03 11 13 Structural Cast-in Place Concrete Forming

1 m³ 19 188.00 3,572.00

03 31 00 Structural Concrete

2 m³ 27 354.00 9,558.00

3 m³ 16 720.00 11,520.00

4 m³ 66 348.00 22,968.00

5 m³ 3 664.00 1,992.00

6 m³ 270 546.00 147,420.00

7 m³ 25 542.00 13,550.00

Notwithstanding the Provisions of the Standard Method of Measurement of Building Works Seventh Edition, 1988 (SMM7) the following,concrete works are measured m³/m including. reinforcement bars and formworks. The Contractor is to include for cost of reinforcement and formwork separately will be entertained due to lack or want of knowledge.

All concrete works herein shall be completed in full compliance with the Drawings and Specification.

Plain Concrete, 20 Mpa for blinding Concrete 50mm thick for Grade Beams, 100mm thick for Blinding Concrete 100mm thick bellow footings and shear wall raft Foundation, poured against the compacted soil, as stated in the Structural notes and Specification.

Reinforced concrete 35 Mpa, foundations ( footings): kind,quality, curing details etc. as stated in the Structural Notes and Specification.

Reinforced concrete 35 Mpa for ground beams; kind,quality, curing details etc. as stated in the Structural Notes and Specification.

Reinfoced concrete beds 35 Mpa for slab with A393 welded wire mesh, on grade; thickness ≤ 150mm, poured againts the compacted soil kind quality, curing details etc.as stated in the Structural Notes and Specification.

Reinforced concrete for substructure columns35 Mpa up to slab on grade; kind quality, curing details etc.as stated in the Structural Notes and Specification

Reinforced concrete 35 Mpa super structure Hollow Core Slabs thick, = 300mm ,4% slope, (kind,quality, curing details etc. as stated in the Structural Notes and Specification.

Reinforced concrete 35 Mpa for super structure beams; kind, quality, curing details etc. as stated in the Structural Notes and Specification.

Page 1158: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

8 m³ 11 836.00 9,196.00

9 m² 273 17.00 4,641.00

CF 224,417.00

BF 224,417.00

CONCRETE (Cont'd)

03 00 00 - Concrete

Additional Items

1

Concrete Topping

1.1 Sand cement / concrete screed above roof 100mm thick m2 276 17.00 4,692.00

1.2 Columns m3 9.44 1035.00 9,770.40

Reinforced concrete 35 Mpa for upstand 150mm wide, 100mm high; kind, quality, curing details etc. as stated in the Structural Notes and Specification.

Sand cement/concrete screed for floors, width > 300mm, (thickness,kind quality,composition mix, nature of base method of construction. Layout and treatments,thermal insulation,moisture resistant treatment method of jointing, etc, as per the Drawings and S

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included

As per client answer for question No (280) dated 23/10/2014

Page 1159: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for CONCRETE

CARRIED TO SUMMARY US Dollar 238,879.40

04 00 00 - Masonry

04 22 00 - Concrete Unit Masonry

Internal walls and Partitions

1 m² 50 34.00 1,700.00

2 m² 90 35.00 3,150.00

External walls

3 m² 368 35.00 12,880.00

04 00 00 - Masonry

Additional Items

Total for Masonry

CARRIED TO SUMMARY US Dollar 17,730.00

05 00 00 METALS

05 53 00 Metal Gratings

1 Steel Grating 1185mm wide. m 20 242.00 4,840.00

All Masonry works herein shall be completed full incompliance with the Drawings and Specification.

100mm thick CMU wall reinforced, vertical, (kind, quality and size of blocks,; type of bond, mix of motar etc. to be included as per the Specification).

200mm thick CMU wall reinforced, vertical, (kind, quality and size of blocks, type of bond, mix of motar etc. to be included as per the Specification)

200mm thick CMU wall reinforced, vertical, (kind, quality and size of blocks, type of bond, mix of motar etc. to be included as per the Specification)

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section,but not mentioned here.Any such items not listed below shall be deemed to be included.

All metals works herein shall be completed in full compliance with the Drawin and Specification.

Page 1160: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2 Steel Grating 800mm wide. m 24 163.00 3,912.00

3 Steel Grating 600mm wide. m 8 122.00 976.00

Additional Items

4 Item

Total for METALS

CARRIED TO SUMMARY US Dollar 9,728.00

07 00 00 THERMAL AND MOISTURE PROTECTION

07 10 00 Damp proofing and Waterproofing

Substructure Waterproofing

1 m² 209 2.00 418.00

2 m² 136 5.00 680.00

3 Ditto - Horizontal surface. m² 75 5.00 375.00

4 m² 85 24.00 2,040.00

5 m² 85 7.00 595.00

6 m² 83 25.00 2,075.00

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section,but not mentioned here.Any such items not listed below shall be deemed to be included.

All works herein shall be completed in full compliance with the Drawings and Specification.

Waterproofing works for substructure with vapour barrier 250 microns,horizontal surface, as per the Drawings and Specification)

Waterproofing works for substructure with two layer of bitumen paint, vertical surface as per the Drawings and Specification.

Waterproofing works for substructure with two layers of approved water proofing membrane, vertical surface, as per the Drawings and Specification).

Protection board for substructure waterproofing works, vertical surface, as per the Drawings and Specification)

Waterproofing works for substructure with two layers of approved water proofing membrane, horizontal surface as per the Drawings and Specification).

Page 1161: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

7 m² 83 12.00 996.00

07 21 13 Board Insulation

8 m² 10 22.00 220.00

9m² 5 22.00 110.00

m² 276 39.00 10,764.00

10

m² 276 23.00 6,348.00

07 00 00 Thermal and Moisture Protection

Additional Items

11

Total for THERMAL AND MOISTURE PROTECTION

CARRIED TO SUMMARY US Dollar 24,621.00

08 00 00 OPENINGS

Note

08 11 13 - Metal Doors and Frames

50mm thick protection screed for water horizontal proofing works, as per the Drawings and Specification).

Waterproofing works for wet area, vertical surface, as per the Drawings and Specification)

Waterproofing works for wet area, horizontal surface as per the Drawings and Specification)

Waterproofing membrane for roof , horizontal surface as per the Drawings and Specification)

100mm thick insulation for water proofing works at roof and balcony water proofing works horizontal surface, as per the Drawings and Specification)

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

All works herein shall be completed in full compliance with the Doors & windows, Schedule Drawings and Specification.

Notwithstanding the Provisions of the Standard Method of Measurement, doors, frames, vision panels, decoration and ironmongery have been measured as a composite item and The Contractor should make due reference to the drawings and specification. No claim for lack or want of knowledge will be entertained.

Page 1162: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1 nr 2 2182.00 4,364.00

2 nr 1 2118.00 2,118.00

08 14 00 - Wood Doors

3 nr 3 1227.00 3,681.00

08 51 13 Aluminum Windows

4 nr 1 271.00 271.00

08 00 00 Openings

Additional Items

5

Supply and fix steel door, 2100mm wide x 2200mm high including H.M. steel frame, type D1, finished with and including paint, all accessories and hardware including but not limited to hinges HDH type, outside door lock SST, lever handles and latch, roses and escutcheons as stated on the drawings and in the Specification.

Supply and fix steel door, 2100mm wide x 2200mm high with louvers 500mm wide x 300mm height including H.M. steel frame, type D2, finished with and including paint, all accessories and hardware including but not limited to hinges HDH type, outside and inside door lock SST, lever handles and latch, roses and escutcheons as stated on the drawings and in the Specification.

Supply and fix wooden door, 900mm wide x 2200mm high including H.M. steel frame, type D3, finished with and including paint, automatic flush bolt for inactive door leaf, weather stripping, all accessories and hardware including but not limited to hinges SHP type, outside door lock DLH, lever handles and latch, wall stop, roses and escutcheons as stated on the drawings and in the Specification.

Supply and fix powder coated aluminum window, 600mm wide x 1000mm high, type W1, with fixed panel , 12mm. Clear tempered glass finished, all accessories and hardware including but not limited to hinges, handle, lock, weather tight strip etc. as stated in the Drawings and Specification.

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Page 1163: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for OPENINGS

CARRIED TO SUMMARY US Dollar 10,434.00

09 00 00 - FINISHES

09 24 00 Cement Plastering

1 m² 623 22.00 13,706.00

2 m² 268 0.00 0.00

External walls

3 Self colour rendering for external wall m² 542 29.00 15,718.00

4 Self colour rendering for Internal side of parapet wall m² 53 29.00 1,537.00

09 30 13 Ceramic Tiling

Floor Tiling

5 m² 5 55.00 275.00

6 m² 276 32.00 8,832.00

Wall tiling

All works herein shall be completed in full compliance with the Drawings and Specification.

Plastering for walls to receive paint finish, width > 300mm, (thickness, kind quality, composition, mix materials, nature of base, method of construction layout and treatment, thermal insulation, moisture resistant treatment, method of jointing etc; as pe

Plastering for ceiling to receive paint finish, width > 300mm, (thickness, kind, quality, composition, mix materials, nature of base, method of construction, layout and treatments, thermal insulation, moisture resistant treatment, method of jointing, etc. as per the Drawings and Specification).

Non Slip Porcelain Stoneware tile flooring, , level or to falls only ≤ 15° from horizontal, fixed over cement sand screed; standard quality, nature of base, method of construction, layout and treatments, thermal insulation, moisture resistant treatment, method of jointing, etc. as per the Drawing and Specification.

Terrazzo tiles on 20mm mortar bed and 20mm layers of sand for roof areas, level or to falls only ≤ 15° from horizontal, fixed over cement sand screed; kind, quality, size, nature of base, method of construction, layout and treatments, thermal insulation, moisture resistant treatment, method of jointing, etc. as per the Drawings and Specification.

Page 1164: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

7 m² 48 111.00 5,328.00

09 67 23 - Resinous Flooring

m² 349 44.00 15,356.00

CF 60,752.00

BF 60,752.00

FINISHES (Cont'd)

09 91 00 - Painting

Wall -Painting

1 m² 623 11.00 6,853.00

Ceiling -Painting

2 m2 268 11.00 2,948.00

09 00 00 Finishes

09 00 00 - FINISHES

Additional Items

Wall tile for toilets and bathrooms walls including plaster, width > 300mm, fixed over cement sand screed; quality, size, nature of base, method of construction, layout and treatments, thermal insulation, moisture resistant treatment, method of jointing, etc. as per the Drawings and Specification

Epoxy resin floor coating; including items mentioned in "Method of Measurements". as per the Drawings and Specification

Painting for walls, girth > 300mm, (kind, quality of materials, painted on cement plastering, preparatory works, priming coat, undercoats, finishing coat, method of application, etc. as per the Drawings No A1-A901 and Specification).

Painting for ceiling, girth > 300mm, (kind, quality of materials, painted on cement plastering, preparatory works, priming coat, undercoats, finishing coat, method of application, etc. as per the Drawings No A1-A905, A1-A901 and Specification).

Page 1165: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3 Item

Total for FINISHES

CARRIED TO SUMMARY US Dollar 70,553.00

21 00 00 FIRE SUPPRESSION

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

All Fire suppression works herein shall be completed full incompliance with the Drawings and Specification.

Page 1166: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

21 22 13 Clean-Agent Fire -Extinguishing Piping

1 Ditto, 40 mm diameter m 26 included in item 5 to 7 below

2 Ditto, 50 mm diameter m 27 included in item 5 to 7 below

3 Ditto, 80 mm diameter m 20 included in item 5 to 7 below

4 Ditto, 100 mm diameter m 8 included in item 5 to 7 below

21 22 16 Clean-Agent Fire -Extinguishing Equipment

5 Set 4 86856.00 347,424.00

6 Set 1 57639.00 57,639.00

7 Set 1 26654.00 26,654.00

21 24 00 Dry-Chemical Fire-Extinguishing Systems

8 nr 1 254.00 254.00

Novec Nozzle nr 13 included in item 5 to 7 above

GENERAL

9 Item 1 INCLUDED

Supply & Installation testing and commissioning of steel pipes (painted). All fire fighting pipes to be completed including but not limited to accessories, fittings, couplings according to NFPA code/ local civil defence code. Including all kind of supports and hangers all in accordance to the specificaHons and drawings.

Supply & Installation testing and commissioning of Clean - Agent system including Cylinder ,sprinkler . not limited to accessories, fittings, defence code. Including all kind of supports and hangers all in accordance to the specificaHons and drawings.

Clean-Agent Cylinder (Novec 1230) with Sprinkler Capacity 919 Kg

Clean-Agent Cylinder (Novec 1230) with Sprinkler Capacity 135 Kg

Clean-Agent Cylinder (Novec 1230) with Sprinkler Capacity 35 Kg

Supply and installation of complete Automatic dry powder (6kg) extinguisher with all necessary accessories, all in accordance with the specifications and drawings.

TESTING, ADJUSTING, AND BALANCING OF MEP SYSTEMS

Allow for Starting up, pressure testing, complete testing and commissioning for all Fire fighting system, including all necessary preparations and attendance for authority approvals.

Page 1167: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

10 Item 1 2045.00 2,045.00

11 Allow for drawing, manuals, approvals & instruction books. Item 1 INCLUDED

12 Allow for protective and decorative painting Item 1 INCLUDED

13 Allow for liaison and coordination with local authorities. Item 1 INCLUDED

CF 434,016.00

BF 434,016.00

FIRE SUPPRESSION (Cont'd)

21 00 00 Fire Suppression

Additional Items

1

Total for FIRE SUPPRESSION

CARRIED TO SUMMARY US Dollar 434,016.00

22 00 00 - PLUMBING

Allow for BMS system to interface with Fire fighting system.

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Page 1168: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

22 05 23 General-Duty Valves for Plumbing Piping

Valves

Isolating Valve

1 20 mm diam. nr 2 20.00 40.00

2 25mm diam. nr 5 25.00 125.00

Pressure Reducing Valve

3 25 mm diam. nr 1 107.00 107.00

22 11 16 Domestic Water Piping

Water Supply System

1-Cold Water Supply

4 20 mm diameter. m 24 16.00 384.00

5 25 mm diameter. m 4 21.00 84.00

2-Hot Water Supply

6 20mm diameter m 6 16.00 96.00

3 - Accessories

7 Hose Bibb 20mm . nr 1 43.00 43.00

8 Pressure Gauge . nr 2 45.00 90.00

9 Water Meter 25 mm. nr 1 1237.00 1,237.00

10 Strainer 25 mm. nr 1 86.00 86.00

22 13 16 Sanitary Waste and Vent Piping

All items hereunder to be described specified code of practice and regulations, kind, quality, size, method of fixing , finishes or surface treatments, etc. as per the Drawings and Specification).

Valves are classified according to type . Material and/or size . Rates include furnishing and installing of valves, testing at manufacturer's premises and on site; diameters of valves and water meter according to pipe diameter which will be connected with it; as per Drawings and Specification.

Domestic water piping is classified by material and diameter. Rates include furnishing and installing of pipes, fittings, accessories, fixing supports, joints, sleeves, special parts, connections, hanger supports. Rates to include all works and materials necessary for

Page 1169: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Sanitary Pipe Works

Pipes and fitting above ground

Waste pipe

11 50 mm diameter. m 12 11.00 132.00

12 75 mm diameter. m 32 17.00 544.00

Pipes and fitting below ground

Waste pipe

13 75 mm diameter. m 11 27.00 297.00

14 110 mm diameter. m 8 36.00 288.00

CF 3,553.00

BF 3,553.00

Plumbing (Cont'd)

22 33 00 Electric Domestic Water Heaters

1 EWH-MVS-01 with (50 litres / 1200 W) capacity. nr 1 275.00 275.00

22 40 00 Plumbing Fixtures

2 Floor Drain (FD) nr 2 192.00 384.00

Sanitary pipe works is classified by material and diameter. Rates include furnishing and installing of pipes, fittings, accessories, fixing support, joints, sleeves , special parts, connections, hanger supports. Rates for pipework below ground also include excavation, backfilling , civil work, trenches and any other accessories or fittings necessary for complete installation of the piping system. Testing of pipes at the manufacturer's premises is included. All as per the Drawings and Specification.

Electric domestic water heaters are classified according to capacity. Rates include furnishing of heater complete with safety valves, air vent, pressure and temperature relief gauges, drain valves, all valves set (angle, gate, non return, etc. .), thermostat, heating element, contactors, switch, support, bolts, nuts, connection of pipes, testing on site, commissioning and putting into service.

All items described hereunder to be of kind, quality, size, nature of base, method of fixing, complete with accessories etc. as per the Drawings nr V1-903 and Specification

Page 1170: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3 Flexible Shower Hose (Sprayer , valves , etc….) nr 1 38.00 38.00

4 Wash basin (WB) nr 1 171.00 171.00

5 nr 1 166.00 166.00

6 Water Closet nr 1 413.00 413.00

22 00 00 - Plumbing

Additional Items

7 nr 1 636.00 636.00

8 Acid Neutralization Pit nr 1 410.00 410.00

Additional Items

9 item 1 INCLUDED

10 item 1 INCLUDED

11 Testing and commissioning of entire installation item 1 INCLUDED

12 Preparation of as-built drawings item 1 INCLUDED

CF 6,046.00

BF 6,046.00

Plumbing (Cont'd)

1 Preparation of operation and maintenance manuals item 1 INCLUDED

2 item

Taps for wash basin including fittings , plugs, valves, connections and waste.

Inspection chamber as per Drawings and Specification; connected directly to sewer network.

Marking the position of holes, mortises and chases in the structure

Identification; plates, discs, labels, tapes, bands, arrows, symbols, letters, numbers and charts; as stated on drawings and in Specification

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Page 1171: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836
Page 1172: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for PLUMBING

CARRIED TO SUMMARY US Dollar 6,046.00

23 07 13 Duct Insulations

1 m² 255 52.00 13,260.00

23 31 00 HVAC Ducts and Casing

Note

2 Gauge 26 kg 77 12.00 924.00

3 Gauge 24 kg 377 12.00 4,524.00

4 Gauge 22 kg 1290 12.00 15,480.00

23 00 00 - HEATING, VENTILATING, AND AIR CONDITONING (HVAC)

All HVAC works shall be completed as per the Drawings and Specification

All Items hereunder to be described with in type, kind quality, thickness,method of fixing, specified codes of practice,etc, as per the Drawings and Specification)

Supply and fix ductwork insulations outdoor for (supply, return, fresh air, exhaust, etc;); , specified codes of practice,etc, as per the Drawings and Specification)

All Items hereunder to be described with in type, kind quality, thickness,method of fixing, specified codes of practice,etc, as per the Drawings and Specification)

Notwithstanding the Provisions of the Standard Method of Measurement internal ductwork is to include insulation to the ductwork. No claim for additional cost due to lack or want of knowledge will be entertained.

Supply and fix insulated indoor galvanized steel sheet metal duct work for all HVAC work as specified and as indicating on drawings, complete with bends, supports, connections, fittings, splices and all accessories to complete work.

Page 1173: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 34,188.00

BF 34,188.00

23 33 13.13 Volume-Control Dampers

Volume Dampers

1 Volume Damper ; 1000x200 mm. nr 9 120.00 1,080.00

2 Volume Damper ; 300x150 mm. nr 1 66.00 66.00

3 Volume Damper ; 300x100 mm. nr 2 62.00 124.00

Motorized Volume Dampers

Motorized Damper ; 700x300 mm. nr 2 817.00 1,634.00

Motorized Damper ; 300x100 mm. nr 2 766.00 1,532.00

23 33 13.16 Fire Dampers

HEATING, VENTILATING, AND AIR CONDITIONING (Cont'd)

All items described hereunder to be of type, kind, quality, size, method of fixing, specified codes of practice, etc. as per the Drawings and Specification

Page 1174: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

4 Motorized Fire / smoke Damper . nr 2 798.00 1,596.00

23 33 19 Duct Silencers

5 Sound Extenuator . nr 2 1470.00 2,940.00

23 34 00 HVAC Fans

Industrial Type Wall Mounted

6 Exhaust Fan (EAF-01) with total air flow 1860 L/S . nr 1 4522.00 4,522.00

7 Exhaust Fan (EAF-02) with total air flow 1860 L/S . nr 1 4522.00 4,522.00

8 Exhaust Fan (EAF-03) with total air flow 545 L/S . nr 1 2532.00 2,532.00

In line ducted

Exhaust Fan (EAF-04) with total air flow 170 L/S . nr 1 572.00 572.00

Wall Mounted

9 Exhaust Fan (EAF-05 ) with total air flow 45 L/S . nr 1 133.00 133.00

10 Exhaust Fan (EAF-06 ) with total air flow 35 L/S . nr 1 133.00 133.00

CF 55,574.00

BF 55,574.00

23 37 00 Air outlets and Inlets

All items hereunder to be described with information such as type, kind, quality, size, method of fixing , specified codes of practice, etc. as per the Drawings and Specification).

All items described hereunder to be of capacity, design, supply, execution, type, kind, quality, size, method of fixing , specified codes of practice, etc. as per the Drawings and Specification.

Supply and install exhaust fan as specified and as indicated in drawing. Fan consists of casing, fan, motor, control, filter, sand trap louver, all electrical works (components, wiring, switches etc.) and all accessories. Electrical power supply 220/1/60.

HEATING, VENTILATING, AND AIR CONDITIONING (Cont'd)

All items hereunder to be described with information such as type, kind, quality, size, method of fixing , specified codes of practice, etc. as per the Drawings and Specification).

Page 1175: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1 Size 1000x200 mm ; 2675 L/s . nr 9 104.00 936.00

2 Size 300x100 mm ; 215L/s . nr 2 40.00 80.00

3 Size 2500x100 mm ; 170 L/s . nr 1 301.00 301.00

4 Bell mouth with VCD and wire mesh ; 1205 L/S. nr 2 236.00 472.00

5 Exhaust air louver (300X100)mm . nr 1 44.00 44.00

6 Exhaust air grill (300X100)mm . nr 2 44.00 88.00

23 82 00 Convection Heating and Cooling Units

7 (PACU-MVS-01) , 3060 L / s , 650 Pa ; Total load 46.7 KW nr 1 24583.00 24,583.00

8 nr 1 24583.00 24,583.00

23 05 93 Testing, Adjusting and Balancing for HVAC

9 Air balancing of the ducting network Item 1 2045.00 2,045.00

Supply and install Painted Supply linear bar air grill with complete accessories.as per the Drawings and Specification.

Supply and install Bell Mouth with complete accessories.as per the Drawings and Specification.

Supply and install exhaust air louver with complete accessories as per the Drawings and Specification.

Supply and install exhaust Grilles with complete accessories as per the Drawings and Specification.

All items hereunder to be described with information such as appropriate to the procurement , capacity, design, supply, execution, type, kind, quality, size, method of fixing , specified codes of practice, etc. as per the Drawings and Specification).

Supply and install Roof Top Package unit specified and as indicated in drawing. Unit to be Supply and install Roof Top Package unit specified and as indicated in drawing. Unit to be louver with filter, valves, controls, all electrical works (components, wiring , etc.) and all accessories. Electrical power supply 400/3/60

(PACU-MVS-02) , 3060 L / s , 650 Pa ; Total load 46.7 KW .

All items hereunder to be described with type of installation, preparatory operations, stages of test (nr), required attendance, applicable codes etc. as per the Drawings and Specification).

Page 1176: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

10 Testing, balancing and commissioning of all the equipment Item 1 410.00 410.00

CF 109,116.00

BF 109,116.00

Additional Items

1 Item 1 INCLUDED

2 Item 1 205.00 205.00

3 Testing and commissioning of entire installation Item 1 INCLUDED

4 Preparation of as-built drawings Item 1 INCLUDED

5 Preparation of operation and maintenance manuals Item 1 INCLUDED

6

6.01 Building Management System Item 154179.00 54,179.00

Total for HVAC

CARRIED TO SUMMARY US Dollar 163,500.00

26 00 00 - ELECTRICAL

HEATING, VENTILATING, AND AIR CONDITIONING (Cont'd)

23 00 00 - Heating, Ventilating, and Air Conditioning (HVAC)

Marking the position of holes, mortises and chases in the structure

Identification; plates, discs, labels, tapes, bands, arrows, symbols, letters, numbers and charts; as stated on drawings and in Specification

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included.

All works hereunder shall be completed as per the Drawings and Specification.

Page 1177: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1 Lighting circuits Item 1 1204.00 1,204.00

2 Power circuits Item 1 475.00 475.00

3 Fire alarm circuits Item 1 45.00 45.00

4 Fan circuits Item 1 555.00 555.00

5 Outdoor lighting circuits Item 1 364.00 364.00

6 Emergency lighting circuits Item 1 27.00 27.00

7 grounding system Item 1 12386.00 12,386.00

CF 15,056.00

Note : the switchgear unit is mentioned in master plan electrical

26 05 19 Low Voltage Electrical Power Conductors and cables

All items hereunder to be of type, kind, number of cores, armoring and sheathings, method of fixing , specified codes of practice, etc. as per the Drawings and Specification).

Notwithstanding the Provisions of the method of measurement, cables have been itemized and referenced to the circuit. The contractor is to make due reference to drawings for full details and is to allow for all cabling, junctions, flexible connections, feeder units etc. required to complete the installation in accordance with the drawings and Specification. No claim for want or lack of knowledge will be entertaineD.

26 05 26 Grounding and Bonding for Electrical Systems

All items hereunder to be described with information such as type, kind, number of cores, armoring and sheathings, method of fixing , specified codes of practice, etc. as per the Drawings and Specification).

Page 1178: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

BF 15,056.00

ELECTRICAL (Cont'd)

26 05 33.13 Conduit for Electrical Systems

1 Lighting circuits Item 1 809.00 809.00

2 Power circuits Item 1 393.00 393.00

3 Fire alarm circuits Item 1 38.00 38.00

4 Fan circuits Item 1 447.00 447.00

5 Outdoor lighting circuits Item 1 311.00 311.00

6 Emergency lighting circuits Item 1 18.00 18.00

26 24 16 Panel boards

7 LLP Item 1 1275.00 1,275.00

26 27 13 Electricity Metering

8 Item

26 27 26 Wiring Devices

Switches & Push Buttons

All items hereunder to be described with information such as type, kind, , method of fixing , specified codes of practice, etc. as per the Drawings and Specification).

Notwithstanding the Provisions of the method of measurement, conduits have been itemized and referenced to the circuit. The contractor is to make due reference to drawings for full details and is to allow for all cabling, junctions, flexible connections, feeder units etc. required to complete the installation in accordance with the drawings and Specification. No claim for want or lack of knowledge will be entertained

All items hereunder to be described with information such as type, kind, rated capacity, method of fixing, cores reference to Specification, fuses, codes of practice, etc. as per the Drawings and Specification).

Page 1179: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

9 One way one gang switch nr 4 10.00 40.00

10 Two way one gang switch nr 2 11.00 22.00

Power Outlets

11 Duplex receptacle outlet, 230V, 20A normal power supply nr 10 19.00 190.00

12 Disconnect switch ,NEMA-4X nr 2 4863.00 9,726.00

CF 28,325.00

BF 28,325.00

ELECTRICAL (Cont'd)

LIGHTING PROTECTION FOR STRUCTURES

1 Lighting Protection System Item 1 7847.00 7,847.00

26 50 00 Lighting

2 nr 6 127.00 762.00

3 nr 32 415.00 13,280.00

4 Down light luminaire, Mounting 1x26W CFL ; type G1. nr 2 204.00 408.00

5 nr 10 294.00 2,940.00

26 00 00 - ELECTRICAL

All items hereunder to be described with information such as appropriate to the procurement , type, kind, quality, size, method of fixing , specified codes of practice, etc. as per the Drawings and Specification).

Supply, installation, testing, for lighting protection system include detailing, roof-mounted air terminals, conductors, sleeves ,grounds rod assembly, complete with equipment, furnishing all materials, and all associated civil works relevant to fixation and installation as specified and shown on drawings for proper installation & operation.

All items hereunder to be described with information such as appropriate to the procurement , type, kind, quality, size, method of fixing , specified codes of practice, etc. as per the Drawings and Specification).

Luminaire, with open end wrap around diffuser,2 no. of fluorescent lamps, electronic ballast & clear prismatic pattern; type C2

Ceiling bracketed explosion protection hazardous fluorescent luminaire installed with 2x36W T8 fluorescent lamp for ADB-f-F control gears; type C5

Luminaries, bracket mounted asymmetrical floodlight with 150W metal haylide lamp; type FL01

Page 1180: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Additional Items

6 Item 1 included

7 Item 1 included

8 Testing and commissioning of entire installation Item 1 included

9 Preparation of as-built drawings Item 1 included

10 Preparation of operation and maintenance manuals Item 1 included

11

11.1 EXIT SIGN nr 1 152.00 152.00

Total for ELECTRICAL

CARRIED TO SUMMARY US Dollar 53,714.00

27 00 00 COMMUNICATIONS

27 16 13 Communications Custom Cable Assemblies

1 Loop Cable and conduit Item 1 1240.00 1,240.00

27 21 29 Data Communication switches and Hubs

Marking the position of holes, mortises and chases in the structure

Identification; plates, discs, labels, tapes, bands, arrows, symbols, letters, numbers and charts; as stated on drawings and in Specification

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included.

All items hereunder to be described with information such as appropriate to the procurement , type, kind, quality, size, method of fixing , specified codes of practice, etc. as per the Drawings and Specification).

Page 1181: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2 Telephone outlet, wall mounted, flush type nr 1 34.00 34.00

3 9U nr 1 906.00 906.00

4 Card reader, smart card nr 3 232.00 696.00

5 Electromagnetic door latch nr 2 380.00 760.00

6 Magnetic door contact switch nr 6 220.00 1,320.00

7 Request to exit button nr 3 306.00 918.00

8 nr 4 1505.00 6,020.00

27 00 00 Communications

Additional Items

9

ADDITIONAL

9.1 Control Panel for Access Control nr 1 1739.00 1,739.00

27 21 33 Data Communications Wireless Access Points

IP fixed type CCTV, wall mounted outdoor camera (weather proof)

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included.

Page 1182: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for COMMUNICATIONS

CARRIED TO SUMMARY US Dollar 13,633.00

28 00 00 ELECTRONIC SAFETY AND SECURITY

28 31 00 Fire Detection and Alarm

1 Addressable, smoke detector nr 5 68.00 340.00

2 Addressable, Manual Pull Station nr 2 68.00 136.00

3 Fire Alarm Horn With Strobe nr 2 142.00 284.00

4 Control Module nr 1 68.00 68.00

5 Fire Alarm Control Panel nr 1 3047.00 3,047.00

6 Power Supply Unit, 24v nr 1 included in the above

7 Loop Cable, 2x1.5mm2 Fire Resistant m 80 9.00 720.00

8 24V Cable, 2x2.5mm2 Fire Resistant m 4 9.00 36.00

28 00 00 Electronic Safety and Security

Additional Items

9

ADDITIONAL (As per Q&A 487)1 nr 1 2299.00 2,299.00

All items hereunder to be described with information such as appropriate to the procurement , type, kind, quality, size, method of fixing , specified codes of practice, etc. as per the Drawings and Specification).

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included.

ACTIVE COMPONENTS (AS PER Q&A 487) DISTRIBUTION CABINET

Page 1183: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for Electronic Safety and Security

CARRIED TO SUMMARY US Dollar 6,930.00

31 00 00 EARTHWORK

31 10 00 Site Clearing

1 Site preparation, clearing site vegetation m² 415 2.00 830.00

31 23 16 Excavation

2 Excavation top soil for preservation, average depth 150mm m² 415 3.00 1,245.00

3 Excavating pits(9 nr), maximum depth ≤ 2.00m. m³ 153 8.00 1,224.00

4 Excavating trenches for grade beams, width ≤ 0.3m m³ 16 10.00 160.00

5 Excavating for trenches drain, width ≤ 0.3m m³ 83 8.00 664.00

31 23 23 .13 Backfill

6 m² 103 12.00 1,236.00

7 m² 265 3.00 795.00

31 23 16.26 Rock Removal

8 m³ 128 4.00 512.00

CF 6,666.00

BF 6,666.00

31 31 16 Termite Control

1 m² 265 1.00 265.00

All works herein shall be completed in full compliance with the Drawings and Specification.

Surface treatment, compacting bottom of excavation, compaction to meet 85% of relative density for cohesion-less or 95% maximum density as determined by ASTM D1557 for cohesive materials per the Drawings and Specification).

Surface treatments, compacting bottom of excavation (method of filling and compactions to be stated as per the Drawings and Specifications)

Disposal of excavated material, off site as stated in the Specification.

Termite control for the horizontal surface (method and type of treatment as per the Drawings and Specifications)

Page 1184: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2 m² 186 0.00 0.00

31 00 00 EARTHWORK

Additional Items

3

Total for EARTHWORK

CARRIED TO SUMMARY US Dollar 6,931.00

03 00 00 Concrete 238,879.40

04 00 00 Masonry 17,730.00

05 00 00 Metal 9,728.00

07 00 00 Thermal and Moisture Protection 24,621.00

08 00 00 Openings 10,434.00

09 00 00 Finishes 70,553.00

21 00 00 Fire Suppression 434,016.00

22 00 00 Plumbing 6,046.00

23 00 00 Heating, Ventilating and Air Conditioning ( HVAC )163,500.00

26 00 00 Electrical 53,714.00

27 00 00 Communications 13,633.00

28 00 00 Electronic Safety and Security 6,930.00

31 00 00 Earthwork 6,931.00

Termite control for vertical surface (method and type of treatment as per the Drawings and Specifications)

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included.

Page 1185: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

US Dollar 1,056,715.40AMOUNT FOR MV SWITCHGEAR ROOM (ES) TO SUMMARY

Page 1186: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Item Nr. Description Unit Qty Rate Amount

WAREHOUSE

03 00 00 - CONCRETE

03 11 13 Structural Cast-in Place Concrete Forming

1 m³ 4 188.00 752.00

03 31 00 Structural Concrete

2 m³ 27 469.00 12,663.00

3 m³ 23 684.00 15,732.00

4 m³ 201 472.00 94,872.00

5 m³ 8 717.00 5,736.00

03 00 00 - CONCRETE

Additional Items

Notwithstanding the Provisions of the Standard Method of Measurement of Building Works Seventh Edition, 1988 (SMM7) the following,concrete works are measured m³/m including. reinforcement bars and formworks. The Contractor is to include for cost of reinforcement and formwork with concrete works. No additional charge or cost for reinforcement and formwork separately will be entertained due to lack or want of knowledge.

All concrete works herein shall be completed in full compliance with the Drawings and Specification.

Plain Concrete 20 Mpa, for blinding Beds, Thickness ≤ 150mm, poured against the compacted soil, as stated in the Structural Notes and Specification.

Reinforced concrete 35 Mpa, foundations ( footings): kind,quality, curing details etc. as stated in the Structural Notes and Specification.

Reinforced concrete 35 Mpa for ground beams; kind,quality, curing details etc. as stated in the Structural Notes and Specification.

Reinfoced concrete beds 35 Mpa for slab with A393 welded wire mesh, on grade; thickness ≤ 150mm, poured againts the compacted soil kind quality, curing details etc.as stated in the Structural Notes and Specification.

Reinforced concrete for substructure columns35 Mpa up to slab on grade; kind quality, curing details etc.as stated in the Structural Notes and Specification

Page 1187: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

6 Item

Total for CONCRETE

CARRIED TO SUMMARY US Dollar 129,755.00

04 00 00 - Masonry

04 22 00 - Concrete Unit Masonry

Internal walls

1 m² 190 83.00 15,770.00

2 m² 48 35.00 1,680.00

04 00 00 - Masonry

Additional Items

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included

All Masonry works herein shall be completed full incompliance with the Drawings and Specification.

300mm thick CMU wall, vertical, comprised with 150mm block work external side, 50mm insulation, 100mm block work internal side, (kind, quality and size of blocks,; type of bond, mix of motar etc. to be included as per the Specification).

Extra over for shot fixing starters to steel at 1400mm centers

Page 1188: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3

As per client Question and Answer No. 296

Internal Walls

3.1 200mm thick CMU wall as per dwg No (SB-A205) m2 320 35.00 11,200.00

Total for Masonry

CARRIED TO SUMMARY US Dollar 28,650.00

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section,but not mentioned here.Any such items not listed below shall be deemed to be included.

Page 1189: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

05 00 00 METALS

05 12 33 STRUCTURAL STEEL FRAMING

1 Columns t 12

2 Beams t 232

3 m 303

4 m 446

5 Fittings t 25

6 Holding down bolts complete with toggle boxes nr 112

Framing, erection

7 Trial erection t 271 0.00 0.00

As per Question and Answer No. (377) Not Needed

8 Permanent erection on site t 271 0.00 0.00

9 Protective painting m² 510 12.00 6,120.00

05 00 00 Metals

Additional Items

10 Item

All metals works herein shall be completed in full compliance with the Drawin and Specification.

Framing fabrication including shop priming; all as drawings and specification

Bracings; L75 x 75 x 6 (measured in meters notwithstanding provisions of standard method of measurement)

Price included in Item 1 of

Division 13 Metal

Building System

Purlins and cladding rails (measured in meters notwithstanding provisions of standard method of measurement)

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section,but not mentioned here.Any such items not listed below shall be deemed to be included.

Page 1190: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for METALS

CARRIED TO SUMMARY US Dollar 6,120.00

07 00 00 THERMAL AND MOISTURE PROTECTION

07 10 00 Damp proofing and Waterproofing

Substructure Waterproofing

1 m² 72 5.00 360.00

2 m² 827 2.00 1,654.00

07 00 00 THERMAL AND MOISTURE PROTECTION

Additional Items

3

3.1 m² 100 5.00 500.00

All works herein shall be completed in full compliance with the Drawings and Specification.

Waterproofing works for substructure with two coats of bitumen paint, vertical surface, as per the Drawings and Specification).

Waterproofing works for substructure with vapour barrier 250 microns, horizontal surface, as per the Drawings and Specification).

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Waterproofing works for substructure with two coats of bitumen paint, horizontal surface,as per the Drawings and Specification).

Page 1191: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for THERMAL AND MOISTURE PROTECTION

CARRIED TO SUMMARY US Dollar 2,514.00

08 00 00 OPENINGS

Note

08 11 13 Metal Doors and Frames

1 nr 2 16572.00 33,144.00

2 nr 2 1839.00 3,678.00

08 00 00 Openings

Additional Items

3

Total for OPENINGS

All works herein shall be completed in full compliance with the Doors & Windows Schedule Drawings and Specification.

Notwithstanding the Provisions of the Standard Method of Measurement, doors, frames, vision panels, decoration and ironmongery have been measured as a composite item and The Contractor should make due reference to the drawings and specification. No claim for lack or want of knowledge will be entertained.

Supply and fix steel framed and cladded sliding door Thick = 45 mm including rails; door,5150mm wide x 3000mm high including steel frame, Type D8; all accessories and hardware including but not limited to hinges HDH type, rails, sliding gear pull handles lock as stated in the Specification.

Supply and fix steel door, 1500mm wide x 2200mm high , Thick = 45 mm including frame, type D7, finished with and including paint, all accessories and hardware including but not limited to hinges HDH type, outside door lock, lever handles and latch, wall stop, roses and escutcheons as stated on the drawings and in the Specification.

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Page 1192: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CARRIED TO SUMMARY US Dollar 36,822.00

09 00 00 - FINISHES

09 24 00 Cement Plastering

1 m² 190 22.00 4,180.00

2 m² 190 29.00 5,510.00

09 91 00 - Painting

Wall -Painting

3 m² 190 11.00 2,090.00

09 00 00 - FINISHES

Additional Items

4 Item

Flooring

4.1 Epoxy paint on flooring m2 635.13 44.00 27,945.72

All works herein shall be completed in full compliance with the Drawings and Specification.

Plastering for walls to receive paint finish, width > 300mm, (thickness, kind quality, composition, mix materials, nature of base, method of construction layout and treatment, thermal insulation, moisture resistant treatment, method of jointing etc; as per the Drawings V1-A901 and Specification).

Self coloured rendering (pre coloured mineral wall coating) for walls, External, width > 300mm, (thickness, kind, quality, composition, mix materials, nature of base, method of construction, layout and treatments, thermal insulation, moisture resistant treatment, method of jointing, etc. as per the Drawings nr V1-A201, V1-A501 and Specification).

Painting for walls, girth > 300mm, (kind, quality of materials, painted on cement plastering, preparatory works, priming coat, undercoats, finishing coat method of application, etc. as per the Drawings and Specification).

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

As per client answer for question No (297) dated 23/10/2014

Page 1193: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for FINISHES

CARRIED TO SUMMARY US Dollar 39,725.72

13 34 19 - METAL BUILDING SYSTEMS

1 Roof coverings; pitch as stated on drawings m² 760 304.00 231,040.00

2 Wall cladding. Vertical m² 781 Price Included in Item Above

3 Back sheeting to rear of parapet m² 113 Price Included in Item Above

4 eaves m 112 Price Included in Item Above

5 Vertical angles m 28 Price Included in Item Above

6 Back gutters and linings m 71 Price Included in Item Above

7 Jambs m 5 59.00 295.00

8 Filler pieces m 112 Price Included in Item Above

9 parapet capping m 112 Price Included in Item Above

10 m 6 1559.00 9,354.00

11 m 3 881.00 2,643.00

13 34 19 - METAL BUILDING SYSTEMS

Additional Items

12 Item

Insulated metal wall and roof cladding system all as per drawings nrs SB A205 and specification

Extra over roof coverings for roof platform refer drawing SB A205 detail 5; 1721mm x 1665mm

Extra over roof coverings for roof platform refer drawing SB A205 detail 5; 1249mm x 1291mm

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Page 1194: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for Metal Building Systems

CARRIED TO SUMMARY US Dollar 243,332.00

21 00 00 FIRE SUPPRESSION

21 11 19 Fire-Department Connection

1 nr 1 552.00 552.00

21 12 13 Fire-Suppression Hoses and Nozzles

2 Fire Hose Reel Cabinet. nr 2 3082.00 6,164.00

21 12 23 Fire-Suppression Hose Valves

3 set 1 1070.00 1,070.00

4 set 1 1094.00 1,094.00

All Fire suppression works herein shall be completed full incompliance with the Drawings and Specification.

Fire Connection Department including Non- return Valve, 100 mm dia.

Fire hose reel cabinet C/W 2-1/2" pressure restricted type landing valve 2-1/2" synthetic Fire hose reel cabinet C/W 2-1/2" pressure restricted type landing valve 2-1/2" synthetic rate also shall be include all set of valves (landing , gate , angle, PRV……,etc.) , Pressure gauges.

Supply and installation valves complete and all necesUS Dollary accessories, all in accordance with the specifications and drawings.

Floor control valve assembly (FCVA) 65 mm .(Prv -OS&Y-gate)

Floor control valve assembly (FCVA) 75 mm .(Prv -OS&Y-gate)

Page 1195: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

5 Alarm Check valve, 100mm diameter. nr 1 1616.00 1,616.00

21 13 00 Fire Suppression Sprinkler System

21 13 13 Wet-Pipe Sprinkler System

6 Pipe, 25 mm diameter m 65 22.00 1,430.00

7 Ditto, 32 mm diameter m 33 26.00 858.00

8 Ditto, 40 mm diameter m 33 30.00 990.00

9 Ditto, 50 mm diameter m 20 37.00 740.00

10 Ditto, 65 mm diameter m 20 52.00 1,040.00

11 Ditto, 75 mm diameter m 13 65.00 845.00

Sprinkler System

12 Sprinkler head (Upright) nr 40 18.00 720.00

CF 17,119.00

BF 17,119.00

FIRE SUPPRESSION (Cont'd)

GENERAL

1 Item 1 410.00 410.00

FIRE SUPPRESSION (Cont'd)

All Fire suppression works herein shall be completed full incompliance with the Drawings and Specification.

Supply & Installation testing and commissioning of steel pipes (painted). All fire fighting pipes to be completed including but not limited to accessories, fittings, couplings according to NFPA code/ local civil defense code. Including all kind of supports and hangers all in accordance to the specifications and drawings.

Supply and Installation of Sprinkler System, all in accordance with the specifications and drawings.

TESTING, ADJUSTING, AND BALANCING OF MEP SYSTEMS

Allow for Starting up, pressure testing, complete testing and commissioning for all Fire fighting system, including all necesUS Dollary preparations and attendance for authority approvals.

Page 1196: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2 Item 1 0.00 0.00

3 Allow for protective and decorative painting Item 1 0.00 0.00

4 Allow for liaison and coordination with local authorities. Item 1 0.00 0.00

21 00 00 Fire Suppression

Additional Items

5 Item

Allow for drawing, manuals, approvals & instruction books.

The contractor to list here and price any items shown in the drawings, mentioned in the specifications or required for the satisfactory completion of this section as per the relevant authority regulations, but not mentioned here. Any such item not listed is

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Page 1197: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for FIRE SUPPRESSION

CARRIED TO SUMMARY US Dollar 17,529.00

22 00 00 - PLUMBING

22 05 23 General-Duty Valves for Plumbing Piping

Valves

Isolating Valve

1 25mm diam. nr 2 20.00 40.00

Pressure Reducing Valve

2 25 mm diam. nr 2 334.00 668.00

22 11 16 Domestic Water Piping

Water Supply System

3 25 mm diameter. m 75 12.00 900.00

3 - Accessories

4 Hose Bibb 20mm . nr 9 43.00 387.00

Sanitary Pipe Works

All items hereunder to be described specified code of practice and regulations, kind, quality, size, method of fixing , finishes or surface treatments, etc. as per the Drawings and Specification).

Valves are classified according to type . Material and/or size . Rates include furnishing and installing of valves, testing at manufacturer's premises and on site; diameters of valves and water meter according to pipe diameter which will be connected with

Domestic water piping is classified by material and diameter. Rates include furnishing and installing of pipes, fittings, accessories, fixing supports, joints, sleeves, special parts, connections, hanger supports. Rates to include all works and materials

Page 1198: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Pipes and fitting below ground

Soil pipe

5 110 mm diameter. m 40 36.00 1,440.00

22 40 00 Plumbing Fixtures

6 Grating 250x250mm. nr 3 266.00 798.00

7 Floor clean out nr 1 202.00 202.00

8 Area drain (AD) nr 3 341.00 1,023.00

9 Oil interceptor nr 1 3229.00 3,229.00

CF 8,687.00

BF 8,687.00

Plumbing (Cont'd)

22 00 00 - Plumbing

Additional Items

Additional Items

1 item 1 INCLUDED

2 item 1 INCLUDED

3 Testing and commissioning of entire installation item 1 INCLUDED

4 Preparation of as-built drawings item 1 INCLUDED

5 Preparation of operation and maintenance manuals item 1 INCLUDED

Sanitary pipe works is classified by material and diameter. Rates include furnishing and installing of pipes, fittings, accessories, fixing support, joints, sleeves , special parts, connections, hanger supports. Rates for pipework below ground also include excavation, backfilling , civil work, trenches and any other accessories or fittings necesUS Dollary for complete installation of the piping system. Testing of pipes at the manufacturer's premises is included. All as per the Drawings and Specification.

All items described hereunder to be of kind, quality, size, nature of base, method of fixing, complete with accessories etc. as per the Drawings and Specification

Marking the position of holes, mortises and chases in the structure

Identification; plates, discs, labels, tapes, bands, arrows, symbols, letters, numbers and charts; as stated on drawings and in Specification

Page 1199: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

6 item

Total for PLUMBING

CARRIED TO SUMMARY US Dollar 8,687.00

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Page 1200: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

23 07 13 Duct Insulations

1 m² 100 52.00 5,200.00

23 23 00 Refrigerant Piping

2 20 mm diameter with max liquid line 10 mm. m 10 33.00 330.00

3 Gauge 20 kg 60 12.00 720.00

4 Gauge 22 kg 320 12.00 3,840.00

5 Gauge 24 kg 305 12.00 3,660.00

23 33 13.13 Volume-Control Dampers

23 00 00 - HEATING, VENTILATING, AND AIR CONDITONING (HVAC)

All HVAC works shall be completed as per the Drawings and Specification

All Items hereunder to be described with in type, kind quality, thickness,method of fixing, specified codes of practice,etc, as per the Drawings and Specification)

Supply and fix ductwork insulations outdoor for (supply, return, fresh air, exhaust, etc;); , specified codes of practice,etc, as per the Drawings and Specification)

Supply and fix refrigerant pipes for FCU from condensing units to indoor installed AC units including fittings, sleeves and all accessories as per the Drawings and Specification

All items hereunder to be described with in type, kind, quality, size, method of fixing , specified codes of practice, placing and method of fixing supports, etc. as per the Drawings and Specification).

Notwithstanding the Provisions of the Standard Method of Measurement internal ductwork is to include insulation to the ductwork. No claim for additional cost due to lack or want of knowledge will be entertained.

Supply and fix insulated indoor galvanized steel sheet metal duct work for all HVAC work as specified and as indicating on drawings, complete with bends, supports, connections, fittings, splices and all accessories to complete the work.

Page 1201: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Volume Dampers

6 Volume Damper ; 650x300 mm. nr 3 96.00 288.00

23 34 00 HVAC Fans

Roof mounted , Up Blast

7 Exhaust Fan (EAF01); NEMA 4X; 20A, 3P, 231V nr 1 3300.00 3,300.00

8 Exhaust Fan (EAF02); NEMA 4X; 20A, 3P, 231V nr 1 3300.00 3,300.00

9 Exhaust Fan (EAF03); NEMA 4X; 20A, 3P, 231V nr 1 3300.00 3,300.00

10 Exhaust Fan (EAF04); NEMA 4X; 20A, 3P, 231V nr 1 1498.00 1,498.00

11 Exhaust Fan (EAF05); NEMA 4X; 20A, 3P, 231V nr 1 1498.00 1,498.00

12 Exhaust Fan (EAF06); NEMA 4X; 20A, 3P, 231V nr 1 1498.00 1,498.00

CF 28,432.00

BF 28,432.00

Base mounted , Centrifugal Fan

1 FAF 01; NEMA 4X; 20A 3P 231V nr 1 2769.00 2,769.00

2 FAF 02; NEMA 4X; 20A 3P 231V nr 1 2769.00 2,769.00

3 FAF 03; NEMA 4X; 20A 3P 231V nr 1 2769.00 2,769.00

4 FAF 04; NEMA 4X; 20A 3P 231V nr 1 2769.00 2,769.00

All items described hereunder to be of type, kind, quality, size, method of fixing, specified codes of practice, etc. as per the Drawings and Specification

All items described hereunder to be of capacity, design, supply, execution, type, kind, quality, size, method of fixing , specified codes of practice, etc. as per the Drawings and Specification.

Supply and install exhaust fan as specified and as indicated in drawing. Fan consists of casing, fan, motor, control, filter, sand trap louver, all electrical works (components, wiring, switches etc.) and all accessories.

HEATING, VENTILATING, AND AIR CONDITIONING (Cont'd)

Supply and install Fresh Air Fan unit as specified and as indicated on drawings complete with fan, pre filter, bag filter, damper and sand trap louver with filter, valves, sound attenuator, controls, all electrical works (components, wiring etc. .) and all accessories.

Page 1202: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

5 FAF 05; NEMA 4X; 20A 3P 231V nr 1 2769.00 2,769.00

6 FAF 06; NEMA 4X; 20A 3P 231V nr 1 2769.00 2,769.00

7 FAF 07; NEMA 4X; 20A 3P 231V nr 1 2299.00 2,299.00

8 FAF 08; NEMA 4X; 20A 3P 231V nr 1 2299.00 2,299.00

9 FAF 08; NEMA 4X; 20A 3P 231V nr 1 2299.00 2,299.00

23 37 00 Air outlets and Inlets

Size 700x500 mm ; 1210 L/s . nr 6 88.00 528.00

Size 500x500 mm ; 800 L/s . nr 3 119.00 357.00

Size 600X600 mm ; 265 L/s. nr 6 245.00 1,470.00

10 nr 1 2971.00 2,971.00

11 nr 1 2971.00 2,971.00

12 nr 1 2971.00 2,971.00

CF 63,211.00

BF 63,211.00

23 05 93 Testing, Adjusting and Balancing for HVAC

All items hereunder to be described with information such as type, kind, quality, size, method of fixing , specified codes of practice, etc. as per the Drawings and Specification).

Supply and install Painted Supply linear bar air grille with complete accessories.as per the Drawings and Specification.

Supply and install 4 way Supply ceiling diffuser with complete accessories.as per the Drawings and Specification.

HEATING, VENTILATING, AND AIR CONDITIONING (Cont'd)

Supply and install concealed fan coil unit as specified and as indicated on drawings. Unit to be complete with air cooled condensing unit, fan, filter, valves, control, thermostat, all electrical works (components , wiring , etc. .) and all accessories. Electrical power supply 220/1/60.

(FCU-01) , 530 L / s , 50 Pa ; Electrical data power 1.8 KW .

(FCU-02) , 530 L / s , 50 Pa ; Electrical data power 1.8 KW .

(FCU-03) , 530 L / s , 50 Pa ; Electrical data power 1.8 KW .

Page 1203: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1 Air balancing of the ducting network Item 1 410.00 410.00

2 Item 1 205.00 205.00

Additional Items

3 Item 1 INCLUDED

4 Item 1 410.00 410.00

5 Testing and commissioning of entire installation Item 1 INCLUDED

6 Preparation of as-built drawings Item 1 INCLUDED

7 Preparation of operation and maintenance manuals Item 1 INCLUDED

8 Item

Total for HVAC

CARRIED TO SUMMARY US Dollar 64,236.00

26 00 00 - ELECTRICAL

All items hereunder to be described with type of installation, preparatory operations, stages of test (nr), required attendance, applicable codes etc. as per the Drawings and Specification).

Testing, balancing and commissioning of all the equipment

23 00 00 - Heating, Ventilating, and Air Conditioning (HVAC)

Marking the position of holes, mortises and chases in the structure

Identification; plates, discs, labels, tapes, bands, arrows, symbols, letters, numbers and charts; as stated on drawings and in Specification

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included.

All works hereunder shall be completed as per the Drawings and Specification.

26 05 19 Low Voltage Electrical Power Conductors and cables

Page 1204: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Note

1 Lighting circuits Item 1 3928.00 3,928.00

2 Power circuits Item 1 730.00 730.00

3 Fan circuits Item 1 2666.00 2,666.00

4 HVAC control circuits Item 1 387.00 387.00

5 grounding system Item 1 4421.00 4,421.00

26 05 33.13 Conduit for Electrical Systems

6 Lighting circuits Item 1 5222.00 5,222.00

7 Power circuits Item 1 620.00 620.00

8 Fan circuits Item 1 1490.00 1,490.00

9 HVAC control circuits Item 1 236.00 236.00

Notwithstanding the Provisions of the method of measurement, cables have been itemized and referenced to the circuit. The contractor is to make due reference to drawings for full details and is to allow for all cabling, junctions, flexible connections, feeder units etc. required to complete the installation in accordance with the drawings and Specification. No claim for want or lack of knowledge will be entertained

26 05 26 Grounding and Bonding for Electrical Systems

All items hereunder to be described with information such as type, kind, number of cores, armoring and sheathings, method of fixing , specified codes of practice, etc. as per the Drawings and Specification).

All items hereunder to be described with information such as type, kind, method of fixing , specified codes of practice, etc. as per the Drawings and Specification).

Notwithstanding the Provisions of the method of measurement, conduits have been itemized and referenced to the circuit. The contractor is to make due reference to drawings for full details and is to allow for all tracking, fixings, type, size, materials, boxes, connections etc. required to complete the installation in accordance with the drawings and Specification. No claim for want or lack of knowledge will be entertained

Page 1205: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

10 Main distribution board (MDB-WH) nr 1 3876.00 3,876.00

11 Lighting and power panel (LPP-WH) nr 1 1275.00 1,275.00

12 Lighting and power panel (LPP-WH) nr 1 2522.00 2,522.00

CF 27,373.00

BF 27,373.00

26 27 13 Electricity Metering

26 27 26 Wiring Devices

Note

Switches & Push Buttons

1 One way one gang switch nr 1 10.00 10.00

5 Two way one gang switch nr 3 11.00 33.00

3 One way two gang switch nr 1 12.00 12.00

4 One way three gang switch nr 1 20.00 20.00

Power Outlets

5 nr 20 19.00 380.00

6 Disconnect switch, NEMA - 4X nr 3 691.00 2,073.00

All items hereunder to be described with information such as type, kind, rated capacity, method of fixing, cores reference to Specification, fuses, background, specified codes of practice, etc. as per the Drawings and Specification).

All items hereunder to be described with information such as type, kind, rated capacity, method of fixing, cores reference to Specification, fuses, codes of practice, etc. as per the Drawings and Specification).

Notwithstanding the Provisions of the Method of Measurement, wiring devices shall include final circuits. No claim for lack or want of knowledge shall be entertained

All items hereunder to be described with information such as appropriate to the procurement , type, kind, quality, size, method of fixing , specified codes of practice, etc. as per the Drawings and Specification).

Duplex receptacle outlet, 230V, 20A normal power supply

Page 1206: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

7 Non-fusible disconnect switch , NEMA 4X ,15A,231V. nr 6 691.00 4,146.00

8 Non-fusible disconnect switch , NEMA 4X ,20A,231V. nr 9 691.00 6,219.00

26 50 00 Lighting

Note

9 nr 14 814.00 11,396.00

10 nr 18 327.00 5,886.00

11 nr 6 373.00 2,238.00

12 nr 10 704.00 7,040.00

13 nr 2 147.00 294.00

CF 67,120.00

BF 67,120.00

26 00 00 - Electrical

Additional Items

1 Item 1 included

2 Item 1 included

3 Testing and commissioning of entire installation Item 1 included

4 Preparation of as-built drawings Item 1 included

5 Preparation of operation and maintenance manuals Item 1 included

Notwithstanding the Provisions of the Method of Measurement, lighting shall include final circuits. No claim for lack or want of knowledge shall be entertained

All items hereunder to be described with information such as appropriate to the procurement , type, kind, quality, size, method of fixing , specified codes of practice, etc. as per the Drawings and Specification).

Luminaries, bracket mounted asymmetrical floodlight with 150W metal haylide lamp; type FL07

Luminaries, ceiling mounted industrial high bay installed with 17" open reflector and 250W MH; type HB2

Luminaries, wall mounted with 2nr fluorescent 36W lamps, electronic ballast; type WL01

Luminaries, ceiling mounted industrial low bay installed with moulded diffuser cover and 250W MH; type LB1

Luminaires; wall mounted emergency exit signs with 8W fluorescent lamp. Electronic ballast and battery backup; type EX

Marking the position of holes, mortises and chases in the structure

Identification; plates, discs, labels, tapes, bands, arrows, symbols, letters, numbers and charts; as stated on drawings and in Specification

Page 1207: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

6 ItemThe Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included.

Page 1208: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for ELECTRICAL

CARRIED TO SUMMARY US Dollar 67,120.00

27 00 00 COMMUNICATIONS

1 CAT6A UTP cables m 100 8.00 800.00

2 24V Loop cable, 2 x 25 mm2 (fire resistant cable) m 76 9.00 684.00

3 Loop cable, 2 x 1.5 mm2 (fire resistant cable) m 125 9.00 1,125.00

27 21 29 Data Communication switches and Hubs

4 Telephone outlet, wall mounted, flush type nr 4 34.00 136.00

5 9U nr 1 1451.00 1,451.00

6 Card reader, smart card nr 2 232.00 464.00

7 Electromagnetic door latch nr 2 380.00 760.00

8 Magnetic door contact switch nr 2 220.00 440.00

9 Request to exit button nr 4 306.00 1,224.00

10 nr 1

27 00 00 Communications

Additional Items

11

All items hereunder to be described with information such as appropriate to the procurement , type, kind, quality, size, method of fixing , specified codes of practice, etc. as per the Drawings and Specification).

27 16 13 Communications Custom Cable Assemblies

27 21 33 Data Communications Wireless Access Points

IP fixed type CCTV, wall mounted outdoor camera (weather proof)

Price included in siteworks

communicati

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included.

Page 1209: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

ADDITIONAL

1 Control Panel for Access Control nr 1 1739.00 1,739.00

Total for COMMUNICATIONS

CARRIED TO SUMMARY US Dollar 8,823.00

28 00 00 ELECTRONIC SAFETY AND SECURITY

28 31 00 Fire Detection and Alarm

1 Supply, install addressable smoke detector nr 8 67.00 536.00

2 nr 4 67.00 268.00

3 nr 4 79.00 316.00

4 Fault isolator - ceiling mounted or as per site situation. nr 1 75.00 75.00

5 nr 1 67.00 67.00

28 00 00 Electronic Safety and Security

Additional Items

All items hereunder to be described with information such as appropriate to the procurement , type, kind, quality, size, method of fixing , specified codes of practice, etc. procurement , type, kind, quality, size, method of fixing , specified codes of practice, etc.procurement , type, kind, quality, size, method of fixing , specified codes of practice, etc.as per the Drawings and Specification).

Manual pull station - 1.2 meters from FFL to the center of the device.

Sounder/fire alarm bell/horn -.3 meters below from ceiling line to the center of the device.

Control module - 0.20 meters below from ceiling line to the center of the device.

Page 1210: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

6

ADDITIONAL (As per Q&A 487)1 nr 1 2914.00 2,914.00

Total for Electronic Safety and Security

CARRIED TO SUMMARY US Dollar 4,176.00

31 00 00 EARTHWORK

31 10 00 Site Clearing

1 Site preparation, clearing site vegetation m² 670 2.00 1,340.00

31 23 16 Excavation

2 m² 670 3.00 2,010.00

3 Excavating pits(16 nr), maximum depth ≤ 2.00m. m³ 105 8.00 840.00

4 Excavating trenches for grade beams, width ≤ 0.3m m³ 24 10.00 240.00

31 23 23.13 Backfill

5 m³ 76 12.00 912.00

31 23 23.23 Compaction

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included.

ACTIVE COMPONENTS (AS PER Q&A 487) DISTRIBUTION CABINET

All works herein shall be completed in full compliance with the Drawings and Specification.

Excavation top soil for preservation, average depth 150mm

Filling to excavations, average thickness > 0.25 m, arising from excavated materials, all fill shall be compacted to 75% relative density for cohesion-less soils as per ASTM D4254/ASTM D4293 or 95% maximum density as determined by ASTM D698 for cohesive material, as per the Drawings and Specifications).

Page 1211: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

6 m² 670 3.00 2,010.00

31 23 16.26 Rock Removal

7 53 4.00 212.00

31 31 16 Termite Control

8 m² 670 1.00 670.00

9 m² 469 0.00 0.00

31 00 00 EARTHWORK

Additional Items

Total for EARTHWORK

CARRIED TO SUMMARY US Dollar 8,234.00

03 00 00 Concrete 129,755.00

04 00 00 Masonry 28,650.00

05 00 00 Metal 6120.00

07 00 00 Thermal and Moisture Protection 2,514.00

08 00 00 Openings 36,822.00

09 00 00 Finishes 39,725.72

13 00 00 Special Construction 243,332.00

21 00 00 Fire Suppression 17,529.00

Surface treatments, compacting bottom of excavation, compaction to meet 85% of relative density for cohesion-less soils or 95% maximum density as determined by ASTM D1557 for cohesive materials per the Drawings and Specifications)

Disposal of excavated material, off site as stated in the Specification

m3

Termite control for the horizontal surface (method and type of treatment as per the Drawings and Specifications)

Termite control for vertical surface (method and type of treatment as per the Drawings and Specifications)

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included.

Page 1212: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

22 00 00 Plumbing 8,687.00

23 00 00 Heating, Ventilating and Air Conditioning ( HVAC )64,236.00

26 00 00 Electrical 67,120.00

27 00 00 Communications 8,823.00

28 00 00 Electronic Safety and Security 4,176.00

31 00 00 Earthwork 8,234.00

AMOUNT FOR WAREHOUSE TO SUMMARY US Dollar 665,723.72

Page 1213: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Item Nr. Description Unit Qty Rate Amount

Medium Swimming Pool

1m3 602 60.00 36,120.00

2 Sand / Quarry Dust Filling m3 83 25.00 2,075.00

3m2 400 120.00 48,000.00

5 Supplying & Placing of Grade 15 Lean concrete m2 400 150.00 60,000.00

6

m3 260 180.00 46,800.00

Finishing Works

1m2 425 60.00 25,500.00

2Water proofing for the external surfaces and construction joints m2 425 70.00 29,750.00

3 Wall Tilling size 8" x 8" m2 425 200.00 85,000.00

4 Floor Tilling size 8" x 8" m2 483 200.00 96,600.00

5 Deck Tilling size 12" x 12" m2 382 250.00 95,500.00

6 Edge Tilling 8" Width m 126 50.00 6,300.00

7 Pool Equipments & Under Water Lighting

8Nr 4 150,000.00 600,000.00

9 63mm dia, water flow inlet , ABS plastic Nr 8 20,000.00 160,000.00

10Pool main drain, ABS plastic U.V.Threaded (345mm x 345mm) Nr 4 10,000.00 40,000.00

11 50mm vaccum suction with ABS Plastic UV Threaded Nr 4 200,000.00 800,000.00

12Nr 11 120,000.00 1,320,000.00

Excavation including removal of roots and growths, clearing the top soil.

Supplying & laying of 1000 gauge polythene / DPM, measured net area. Rate shall include for upturns & over laps.

Supply & Pour Grade 30 concrete (Maximum Aggregate Size is ¾") for rate including mixing, hoisting, placing in position and vibration with a mechanical vibrator, in all three pools including gutter & deck.

Water proofing for the internal surfaces and construction joints with plastering to make the surface fair, smooth and water tight.

Fiber glass and polyester resin , non corrosive fiber glass with U/V treated filter. with multiport valve valve , pressure guage and filter media

Unde water lights complete with 100w/12v. With step down transformer & wired to working order and according to the manufactures specification water seal.

Page 1214: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

13Nr 4 1,000.00 4,000.00

14Nr 4 1,000.00 4,000.00

15 18" Commercial vaccum head with inbuilt brush Nr 4 1,500.00 6,000.00

16 15m Flexible floating vaccum hose Nr 4 3,000.00 12,000.00

SUBTOTAL 3,477,645.00

MULTIPLY BY 1 Nr. 1 3,477,645.00

3,477,645.00

Two step ladder made of AISI 316 stainless steel inclusive of the treads

Three step ladder made of AISI 316 stainless steel inclusive of the treads

AMOUNT FOR Medium Swimming Pool FORWARD TO SUMMARY

Page 1215: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Item Nr. Description Unit Qty Rate Amount

Secondry Swimming Pool

1m3 334 60.00 20,040.00

2 Sand / Quarry Dust Filling m3 46 25.00 1,150.00

3m2 222 120.00 26,640.00

5 Supplying & Placing of Grade 15 Lean concrete m2 222 150.00 33,300.00

6

m3 144 180.00 25,920.00

Finishing Works

1m2 236 60.00 14,160.00

2Water proofing for the external surfaces and construction joints m2 236 70.00 16,520.00

3 Wall Tilling size 8" x 8" m2 236 200.00 47,200.00

4 Floor Tilling size 8" x 8" m2 268 200.00 53,600.00

5 Deck Tilling size 12" x 12" m2 212 250.00 53,000.00

6 Edge Tilling 8" Width m 70 50.00 3,500.00

7 Pool Equipments & Under Water Lighting

8Nr 2 150,000.00 300,000.00

9 63mm dia, water flow inlet , ABS plastic Nr 4 20,000.00 80,000.00

10Pool main drain, ABS plastic U.V.Threaded (345mm x 345mm) Nr 2 10,000.00 20,000.00

11 50mm vaccum suction with ABS Plastic UV Threaded Nr 2 200,000.00 400,000.00

12Nr 6 120,000.00 720,000.00

Excavation including removal of roots and growths, clearing the top soil.

Supplying & laying of 1000 gauge polythene / DPM, measured net area. Rate shall include for upturns & over laps.

Supply & Pour Grade 30 concrete (Maximum Aggregate Size is ¾") for rate including mixing, hoisting, placing in position and vibration with a mechanical vibrator, in all three pools including gutter & deck.

Water proofing for the internal surfaces and construction joints with plastering to make the surface fair, smooth and water tight.

Fiber glass and polyester resin , non corrosive fiber glass with U/V treated filter. with multiport valve valve , pressure guage and filter media

Unde water lights complete with 100w/12v. With step down transformer & wired to working order and according to the manufactures specification water seal.

Page 1216: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

13Nr 2 1,000.00 2,000.00

14Nr 2 1,000.00 2,000.00

15 18" Commercial vaccum head with inbuilt brush Nr 2 1,500.00 3,000.00

16 15m Flexible floating vaccum hose Nr 2 3,000.00 6,000.00

SUBTOTAL 1,828,030.00

MULTIPLY BY 2 Nr. 2 3,656,060.00

3,656,060.00

Two step ladder made of AISI 316 stainless steel inclusive of the treads

Three step ladder made of AISI 316 stainless steel inclusive of the treads

AMOUNT FOR Secondry Swimming Pool FORWARD TO SUMMARY

Page 1217: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Item Nr. Description Unit Qty Rate Amount

Children's Swimming Pool

1m3 167 60.00 10,020.00

2 Sand / Quarry Dust Filling m3 23 25.00 575.00

3m2 111 120.00 13,320.00

5 Supplying & Placing of Grade 15 Lean concrete m2 111 150.00 16,650.00

6

m3 72 180.00 12,960.00

Finishing Works

1m2 118 60.00 7,080.00

2Water proofing for the external surfaces and construction joints m2 118 70.00 8,260.00

3 Wall Tilling size 8" x 8" m2 118 200.00 23,600.00

4 Floor Tilling size 8" x 8" m2 134 200.00 26,800.00

5 Deck Tilling size 12" x 12" m2 106 250.00 26,500.00

6 Edge Tilling 8" Width m 35 50.00 1,750.00

7 Pool Equipments & Under Water Lighting

8Nr 1 150,000.00 150,000.00

9 63mm dia, water flow inlet , ABS plastic Nr 2 20,000.00 40,000.00

10Pool main drain, ABS plastic U.V.Threaded (345mm x 345mm) Nr 1 10,000.00 10,000.00

11 50mm vaccum suction with ABS Plastic UV Threaded Nr 1 200,000.00 200,000.00

12Nr 3 120,000.00 360,000.00

Excavation including removal of roots and growths, clearing the top soil.

Supplying & laying of 1000 gauge polythene / DPM, measured net area. Rate shall include for upturns & over laps.

Supply & Pour Grade 30 concrete (Maximum Aggregate Size is ¾") for rate including mixing, hoisting, placing in position and vibration with a mechanical vibrator, in all three pools including gutter & deck.

Water proofing for the internal surfaces and construction joints with plastering to make the surface fair, smooth and water tight.

Fiber glass and polyester resin , non corrosive fiber glass with U/V treated filter. with multiport valve valve , pressure guage and filter media

Unde water lights complete with 100w/12v. With step down transformer & wired to working order and according to the manufactures specification water seal.

Page 1218: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

13Nr 1 1,000.00 1,000.00

14Nr 1 1,000.00 1,000.00

15 18" Commercial vaccum head with inbuilt brush Nr 1 1,500.00 1,500.00

16 15m Flexible floating vaccum hose Nr 1 3,000.00 3,000.00

SUBTOTAL 914,015.00

MULTIPLY BY 2 Nr. 2 1,828,030.00

1,828,030.00

Two step ladder made of AISI 316 stainless steel inclusive of the treads

Three step ladder made of AISI 316 stainless steel inclusive of the treads

AMOUNT FOR Children's Swimming Pool FORWARD TO SUMMARY

Page 1219: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Item Nr. Description Unit Qty Rate Amount

SITE DEVELOPMENT

SITE WORKS

Excavation, Backfilling and Compacting to Finished Grade Level

1 General Excavation m3 76,688 6.00 460,128.00

Backfilling and Compaction

2 Backfilling from Excavated Material m3 76,688 13.00 996,944.00

3 Imported Backfilling m3 424,439 16.00 6,791,024.00

ROAD NETWORKS

4 Site Clearing m3 110,600 2.00 221,200.00

5 Excavating top soil for preservation, average depth 150mm. m2 110,600 3.00 331,800.00

6 Asphalt Concrete Wearing Course; 50 mm thickness m2 84,600 9.00 761,400.00

7 Asphalt Concrete Wearing Course; 70 mm thickness m2 18,750 13.00 243,750.00

8 Asphalt Concrete Base Course; 100 mm thickness m2 84,600 18.00 1,522,800.00

9 Aggregate Base Course; 250 mm thickness m2 84,600 11.00 930,600.00

10 Aggregate Base Course; 200 mm thickness m2 18,750 9.00 168,750.00

11 Compacted Sub-Grade m2 103,350 3.00 310,050.00

12 Tack coat m2 84,600 1.00 84,600.00

13 Prime Coat m2 103,350 1.00 103,350.00

Speed Bumps and Intersections

14 Interlock Tiles; 100 mm length x 200 mm width x 75 mm thickness m2 5,750 24.00 138,000.00

15 Sand Bedding; 25 mm thickness m2 5,750 7.00 40,250.00

16 Reinforced Concrete m3 1,600 222.00 355,200.00

17 Blinding Concrete, 50 mm thick m3 370 188.00 69,560.00

Page 1220: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

###

###

Road Markings

1 Center line marking; 120 mm width x 3,000 mm lengtth - L1 nr 800 8.00 6,400.00

2 No passing line marking; 120 mm width x 9,000 mm length - L2 nr 14 24.00 336.00

3 Stop line marking; 300 mm width - L3 m 100 13.00 1,300.00

4 Parking edge marking; 120 mm width x 1,000 mm length - L4 nr 5,415 4.00 21,660.00

5 Parking delineator marking; 120 mm width - L5 m 6,820 3.00 20,460.00

6 Pedestrian crossing marking; 500 mm width x 2,000 mm length - L nr 182 27.00 4,914.00

7 Edge line marking; 200 mm wide - L7 m 1,426 5.00 7,130.00

8 Channelizing line marking; 240 mm width - L9 m 267 9.00 2,403.00

9 Giveway line marking; 450 mm wide x 300 mm high - L10 nr 60 40.00 2,400.00

10 Straight Arrow; A1 nr 190 53.00 10,070.00

11 Combined Straight/Right and Straight/Left Arrow; A2 and A3 nr 89 68.00 6,052.00

Page 1221: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

12 Left Turn and Right Turn Arrow; A4 and A5 nr 41 68.00 2,788.00

13 Combined Left/Right Arrow; A6 nr 41 79.00 3,239.00

14 Combined Left/Right/Straight Arrow; A7 nr 8 89.00 712.00

15 Disabled Parking; D5 nr 23 183.00 4,209.00

Road Signs

16 R 1-1; Stop Sign nr 23 517.00 11,891.00

17 R 2-1; Give Way Sign nr 12 436.00 5,232.00

18 R 3-1 (30); Speed Limit Sign m 42 517.00 21,714.00

19 R 5-1; Entry Prohibited Sign nr 1 517.00 517.00

20 R 15-3; Pass Both Sides Sign m 2 517.00 1,034.00

21 R 17-1R; Mandatory Through Sign nr 2 517.00 1,034.00

22 R 17-6R; Mandatory Right Sign m 3 517.00 1,551.00

23 R 18-1; Traffic Rotary Sign m 11 517.00 5,687.00

24 I 9-1; Parking Sign nr 220 470.00 103,400.00

25 I 9-2L; Side Parking Left nr 3 470.00 1,410.00

26 I 9-2R; Side Parking Right nr 7 470.00 3,290.00

27 I 9-4; Handicapped Parking Sign nr 15 470.00 7,050.00

28 I 6-1; No Through Road Sign nr 1 470.00 470.00

29 W 1-1L; Left Bend Sign nr 12 436.00 5,232.00

30 W 1-1R; Right Bend Sign nr 14 436.00 6,104.00

31 W 6-1; Speed Bump Sign nr 102 436.00 44,472.00

32 W 11-2; Pedestrian Crossing Sign nr 40 436.00 17,440.00

331,601.00

331,601.00

Curb and Wheel Stopper

Page 1222: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1 Barrier Curb; 150 mm width x 300 mm height m 22,735 21.00 477,435.00

2 Edge Curb; 500 mm length x 100 mm width x 200 mm height m 790 21.00 16,590.00

3 Precast Concrete Wheel Stopper nr 212 75.00 15,900.00

509925

Page 1223: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

AMOUNT FOR SITEWORKS AND ROADS TO SUMMARY US Dollar. ###

Page 1224: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Item Nr. Description Unit Qty

SITE DEVELOPMENT

DOMESTIC AND FIRE WATER SUPPLY DISTRIBUTION SYSTEM

Trench Excavation

Trench excavation to a depth and the width as per specification and drawings. Works

include getting required permissions, secure safety guards, signboards, earthwork support,

consolidation of trench bottoms, trimming excavations, filling with compaction and filling

materials, disposal of surplus excavated materials and all requirements needed to complete

works of laying pipes. As indicated in the Contract drawings and Ministry of Water and

Electricity/ NWC Water network Specifications section 2.03mentioned in the Contract

documents.

1 Excavating trenches for pipe below ground level, pipe size ≤ 200 mm, average depth 1250 m 16,810

mm - 1500 mm

2 Excavating trenches for pipe below ground level, pipe nominal size 250 mm, average depth m 135

1500 mm - 1750 mm

3 Excavating trenches for pipe below ground level, pipe size nominal 300 mm, average depth m 139

1500 mm - 1750 mm

4 Excavating trenches for pipe below ground level, pipe size nominal 315 mm, average depth m 63

1500 mm - 1750 mm

Pipe Bedding

5 Granular bedding and initial backfill including supply and compaction with suitable m2 6,380

equipment's and all requirements to complete work as indicated in drawings and NWC

Water network Specifications section 2.04

6 Beds and surroundings width 650 mm for pipe 110 mm diameter nominal size m 7,404

7 Beds and surroundings width 650 mm for pipe 125 mm diameter nominal size m 74

8 Beds and surroundings width 650 mm for pipe 150 mm diameter nominal size m 7,768

9 Beds and surroundings width 700 mm for pipe 160 mm diameter nominal size m 531

10 Beds and surroundings width 700 mm for pipe 180 mm diameter nominal size m 132

11 Beds and surroundings width 700 mm for pipe 200 mm diameter nominal size m 161

12 Beds and surroundings width 750 mm for pipe 250 mm diameter nominal size m 58

Page 1225: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

13 Beds and surroundings width 850 mm for pipe 300 mm diameter nominal size m 139

14 Beds and surroundings width 850 mm for pipe 315 mm diameter nominal size m 63

Backfilling

1 Backfilling to finish ground level with approved selected excavated material from trench m3 7,900

excavation including supply, warning tape and well compacted to 95% of maximum dry

density with suitable equipment's and all requirements to complete work as shown on the

contract drawings and mentioned in the contract documents.

Disposal

2 Disposal of surplus material to authorised tipping or as directed by Engineer. m3 2,530

Valves

Supply and install butterfly valves with NP 16 bar on water mains and work shall include

supply and installation of all valve accessories, couplings, marker posts, concrete base below

the valve and all necessary according to specifications and drawings for the following

diameters. As indicated in drawings and NWC Water network Specifications section 4.04

3 300 mm diameter Ea. 3

Supply and install gate valves with NP 16 bars and work shall include supply and installation

of all valve accessories, surface box, stem, marker posts, couplings and concrete support

below the valve and according to specifications and drawings for the following diameters: As

indicated in drawings and NWC Water network Specifications section 4.04 (For HDPE pipes)

Page 1226: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

4 110 mm diameter Ea. 40

5 160 mm diameter Ea. 3

6 180 mm diameter Ea. 1

7 250 mm diameter Ea. 1

Supply and install gate valves with Class K9, PN-16 and work shall include supply and

installation of all valve accessories, surface box, stem, marker posts, couplings and concrete

support below the valve and according to specifications and drawings for the following

diameters: As indicated in drawings and NWC Water network Specifications section 4.04

(For DI pipes)

8 150 mm diameter Ea. 27

9 200 mm diameter Ea. 13

10 250 mm diameter Ea. 1

Presure Reducing Valve

11 150 mm diameter Ea. 4

12 200 mm diameter Ea. 1

Supply and install washout valves NP 16 bars and work shall include supply, installation, all

parts, couplings, valves accessories, marker posts and all what is needed according to

specifications and drawings on the water mains with the following diameters. As indicated

Page 1227: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

in drawings and NWC Water network Specifications section 4.04

1 100 mm diameter Ea. 2

Supply and install air release valves supplied with isolating valves and 16 bars pressure.

Works shall include supply and installation, all parts, couplings, valve accessories and marker

posts and all what is needed according to specifications and drawings on water mains with

the following diameters. As indicated in drawings and NWC Water network Specifications

section 4.04

2 40 mm diameter Ea. 2

Valve Chambers

Supply and Construct reinforced concrete chamber for Butterfly valves as shown on

drawings and in specifications. Work shall include excavation, backfilling, reinforced and

plain concrete works, insulation, supply and, installation of covers and steps and all

accessories and pipes needed to connect valves in addition to surface reinstatement and all

requirements needed to finish work as follows. As indicated in drawings and NWC Water

network Specifications section 4.06

3 Single Butterfly valve chamber Ea. 3

Supply and Construct reinforced concrete chamber for Washout valves as shown on

drawings and in specifications. Work shall include excavation, backfilling, reinforced and

plain concrete works, insulation, supply and, installation of covers and steps, all accessories

and pipes needed to connect valves in addition to surface reinstatement and all

requirements needed to finish work as follows. As indicated in drawings and NWC Water

network Specifications section 4.06

4 Washout Valve Chamber Ea. 2

Supply and Construct reinforced concrete chamber for Air valves as shown on drawings and

in specifications. Work shall include excavation, backfilling, reinforced and plain concrete

works, insulation, supply and, installation of covers and steps, all accessories and pipes

needed to connect valves in addition to surface reinstatement and all requirements needed

to finish work as follows. As indicated in drawings and NWC Water network Specifications

section 4.06

5 Air Valve Chamber Ea. 2

Supply and Construct reinforced concrete chamber for Pressure reducing valves as shown on

drawings and in specifications. Work shall include excavation, backfilling, reinforced and

plain concrete works, insulation, supply and, installation of covers and steps, all accessories

and pipes needed to connect valves in addition to surface reinstatement and all

requirements needed to finish work as follows. As indicated in drawings and NWC Water

network Specifications section 4.06

Page 1228: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

6 Pressure Reducing Valve Chamber Ea. 5

Distribution Pipes

Supply and install High Density Polyethylene (HDPE) pipe, NP 16 bars, and include supply,

installation and protection of pipes and accessories, thrust blocks pressure tests, cleaning

disinfection, surveying and all works needed to complete works as per specifications for the

following pipe diameters. As indicated in drawings and NWC Water network Specifications

section 4.02 and 4.03

1 110 mm diameter m 7,404

2 125 mm diameter m 74

3 160 mm diameter m 531

4 180 mm diameter m 132

5 200 mm diameter m 161

6 250 mm diameter m 77

8 315 mm diameter m 63

Supply and install Ductile Iron (DI) pipes, Class K9, PN-16 and Works shall include supply,

installation and protection of pipes and accessories and thrust blocks pressure tests,

cleaning disinfection, surveying and all works needed to complete works as per

specifications for the following pipe diameters. As indicated in drawings and NWC Water

network Specifications section 4.02 and 4.03

9 150 mm diameter m 7,768

10 200 mm diameter m 790

Page 1229: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

11 250 mm diameter m 58

12 300 mm diameter m 139

Fire Hydrant (FH)

13 Supply, installation and construction of dry barrel breakaway type fire hydrant including Ea. 74

isolation gate valves and associated pipes and fittings required to complete the work. Work

shall also include excavation, backfilling, reinstatement of surfaces, reinforced / plain

concrete works, insulation, protection, testing, connection and supply and installation of all

parts needed to complete the work as shown on the contract drawings and specified in the

contract documents.

Fire hose cabinet connection for DI pipes

14 100 mm diameter m 1,420

15 100 mm gate valve for fire hose cabinet connection Ea. 91

16 100 mm end cap for fire hose cabinet connection Ea. 91

House Service Connection

Supply and construct HDPE house connections according to specifications and drawings,

work shall include excavating, backfilling, bedding, surfaces reinstatement, removing

excavated material, obtaining permissions, secure the site with safety guards and supply

accessories and vertical and horizontal installation of HDPE pipes 16 bar including ferrule

cock, water meter, box connections, testing, disinfection, spindles and all the necessary

material or work to ensure the work completion. As indicated in drawings and NWC Water

network Specifications section 4.04

17 Single, Double H.C. as per drawings Ea. 292

18 Triple H.C. as per drawings Ea. 15

House connection for HDPE pipes

19 32 mm diameter m 3,412

20 50 mm diameter m 4,127

21 75 mm diameter m 173

22 End cap for a automatic sprinkler system Ea. 8

23 House connection for HDPE pipes, 63mm diameter m 193

24 House connection for HDPE pipes, 90mm diameter m 492

25 House connection for HDPE pipes, 110mm diameter m 43

Page 1230: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

AMOUNT FOR SITE WORKS - DOMESTIC AND FIRE WATER TO SUMMARY

Page 1231: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Rate Amount

11.00 184,910.00

14.00 1,890.00

16.00 2,224.00

17.00 1,071.00

0.00 0.00

12.00 88,848.00

12.00 888.00

12.00 93,216.00

13.00 6,903.00

14.00 1,848.00

14.00 2,254.00

16.00 928.00

Page 1232: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

20.00 2,780.00

20.00 1,260.00

CF 389,020.00

BF 389,020.00

13.00 102,700.00

6.00 15,180.00

1105.00 3,315.00

Page 1233: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

891.00 35,640.00

1373.00 4,119.00

1656.00 1,656.00

1830.00 1,830.00

1373.00 37,071.00

1656.00 21,528.00

1830.00 1,830.00

3704.00 14,816.00

4930.00 4,930.00

CF 244,615.00

BF 244,615.00

Page 1234: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

965.00 1,930.00

415.00 830.00

6309.00 18,927.00

5509.00 11,018.00

5034.00 10,068.00

Page 1235: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

9369.00 46,845.00

CF 89,618.00

BF 89,618.00

38.00 281,352.00

44.00 3,256.00

61.00 32,391.00

71.00 9,372.00

82.00 13,202.00

116.00 8,932.00

164.00 10,332.00

131.00 1,017,608.00

152.00 120,080.00

Page 1236: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

186.00 10,788.00

226.00 31,414.00

6169.00 456,506.00

101.00 143,420.00

891.00 81,081.00

included

1681.00 490,852.00

1821.00 27,315.00

35.00 119,420.00

38.00 156,826.00

43.00 7,439.00

included

40.00 7,720.00

48.00 23,616.00

52.00 2,236.00

Page 1237: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3055158

US Dollar. 3,778,411.00

Page 1238: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Item Nr. Description Unit Qty

SITE DEVELOPMENT

STORM DRAINAGE SYSTEM

Trench Excavation

Trench excavation to a depth and the width as per specification and drawings. Works

include getting required permissions, secure safety guards, signboards, earthwork support,

consolidation of trench bottoms, trimming excavations, filling with compaction and filling

materials, disposal of surplus excavated materials and all requirements needed to complete

works of laying pipes. As indicated in the Contract drawings and mentioned in the Contract

documents.

1 Excavating trenches, pipes ≤ 250mm diameter nominal size, average depth 1500mm - m 2,309

1750mm

2 Ditto for pipes 315mm diameter nominal size average depth 1750mm - 2000mm m 2,002

3 Ditto for pipes 400mm diameter nominal size average depth 1750mm - 2000mm m 733

4 Ditto for average depth 2000mm - 2250mm m 354

5 Ditto for average depth 2250mm - 2500mm m 243

6 Ditto for average depth 2500mm - 2750mm m 96

7 Ditto for average depth 3000mm - 3250mm m 36

8 Ditto for average depth 3250mm - 3500mm m 44

9 Ditto for average depth 3500mm - 4000mm m 106

10 Excavating trenches for pipes 500mm diameter nominal size average depth 1750mm - m 70

2000mm

11 Ditto for average depth 2000mm - 2250mm m 449

12 Ditto for average depth 2500mm - 2750mm m 295

13 Ditto for average depth 2750mm - 3000mm m 59

14 Excavating trenches for pipes 600mm diameter nominal size average depth 2250mm - m 596

2500mm

15 Ditto for average depth 2500mm - 2750mm m 186

Page 1239: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

16 Ditto for average depth 2750mm - 3000mm m 186

17 Ditto for average depth 3750mm - 4000mm m 22

Trench Excavation (cont'd)

1 Excavating trenches for pipes 700mm diameter nominal size average depth 2000mm - m 237

2250mm

2 Ditto for average depth 2250mm - 2500mm m 193

3 Ditto for average depth 3750mm - 4000mm m 149

4 Excavating trenches for pipes 800mm diameter nominal size average depth 2250mm - m 81

2500mm

5 Ditto for average depth 2500mm - 2750mm m 30

6 Ditto for average depth 2750mm - 3000mm m 121

7 Ditto for average depth 3000mm - 3250mm m 45

8 Ditto for average depth 3250mm - 3500mm m 45

9 Ditto for average depth 3750mm - 4000mm m 110

10 Excavating trenches for pipes 900mm diameter nominal size average depth 2500mm - m 114

2750mm

Page 1240: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

11 Ditto for average depth 3000mm - 3250mm m 30

12 Ditto for average depth 4000mm - 4250mm m 127

13 Excavating trenches for pipes 1000mm diameter nominal size average depth 3000mm - m 13

3250mm

14 Ditto for average depth 3750mm - 4000mm m 33

15 Ditto for average depth 4000mm - 4250mm m 184

16 Excavating trenches for pipes 1100mm diameter nominal size average depth 2750mm - m 112

3000mm

17 Excavating trenches for pipes 1200mm diameter nominal size average depth 2750mm - m 522

3000mm

18 Ditto for average depth 3000mm - 3250mm m 59

19 Ditto for average depth 3250mm - 3500mm m 266

20 Ditto for average depth 3500mm - 3750mm m 48

21 Ditto for average depth 3750mm - 4000mm m 48

Pipe Bedding and Surrounds

Beds and surrounds with compacted soil, 150mm thick bed and 300mm thick surround as

Page 1241: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

indicated in the Contract drawings and mentioned in the Contract documents.

1 Beds and surrounds width 750mm for pipes 250mm diameter nominal size m 2,309

2 Beds and surrounds width 850mm for pipes 315mm diameter nominal size m 2,002

3 Beds and surrounds width 950mm for pipes 400mm diameter nominal size m 1,612

4 Beds and surrounds width 1100mm for pipes 500mm diameter nominal size m 873

5 Beds and surrounds width 1250mm for pipes 600mm diameter nominal size m 990

6 Beds and surrounds width 1350mm for pipes 700mm diameter nominal size m 579

7 Beds and surrounds width 1500mm for pipes 800mm diameter nominal size m 432

8 Beds and surrounds width 1600mm for pipes 900mm diameter nominal size m 271

9 Beds and surrounds width 1750mm for pipes 1000mm diameter nominal size m 230

10 Beds and surrounds width 1900mm for pipes 1100mm diameter nominal size m 112

11 Beds and surrounds width 2000mm for pipes 1200mm diameter nominal size m 783

12 Beds and surrounds with concrete, 200mm thick bed and 200mm thick surround width m 160

1600mm for pipes 1200mm diameter nominal size, as indicated in the Contract drawings

and mentioned in the Contract documents.

Provisional Quantities

Provisional Quantities for beds and surrounds with concrete, 200mm thick bed and 200mm

thick surround as indicated in the Contract drawings and mentioned in the Contract

documents.

13 Beds and surrounds width 600mm for pipes 200mm diameter nominal size m 23

14 Beds and surrounds width 715mm for pipes 315mm diameter nominal size m 18

14 Beds and surrounds width 800mm for pipes 400mm diameter nominal size m 16

Page 1242: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Provisional Quantities (cont'd)

1 Beds and surrounds width 900mm for pipes 500mm diameter nominal size m 10

2 Beds and surrounds width 1000mm for pipes 600mm diameter nominal size m 10

3 Beds and surrounds width 1100mm for pipes 700mm diameter nominal size m 10

4 Beds and surrounds width 1200mm for pipes 800mm diameter nominal size m 10

5 Beds and surrounds width 1300mm for pipes 900mm diameter nominal size m 10

6 Beds and surrounds width 1400mm for pipes 1000mm diameter nominal size m 10

7 Beds and surrounds width 1500mm for pipes 1100mm diameter nominal size m 10

8 Beds and surrounds width 1600mm for pipes 1200mm diameter nominal size m 10

UPVC Pipe

Laying of UPVC gravity pipes in trenches including supply, installation and protection for

pipes and fittings, thrust blocks, leakage tests, operation surveying works and all necessary

works as per specifications for the following pipe diameters. As indicated in Contract

drawings and mentioned in the Contract documents.

9 UPVC pipes in trenches, 315 mm diameter nominal size m 2,002

Perforated UPVC Pipe

Laying of perforated UPVC pipes in trenches including supply, installation and protection

Page 1243: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

for pipes and fittings, thrust blocks, leakage tests, operation surveying works and all

necessary works as per specifications for the following pipe diameters. As indicated in

Contract drawings and mentioned in the Contract documents.

10 UPVC perforated pipes in trenches, 250 mm diameter nominal size m 2,309

Reinforced Concrete Pipe

Laying of reinforced concrete gravity pipes in trenches including supply, installation and

protection for pipes and fittings, thrust blocks, leakage tests, operation surveying works

and all necessary works as per specifications for the following pipe diameters. As indicated

in Contract drawings and mentioned in the Contract documents.

11 Reinforced concrete pipes in trenches, 400mm diameter nominal size m 1,612

12 Reinforced concrete pipes in trenches, 500mm diameter nominal size m 873

13 Reinforced concrete pipes in trenches, 600mm diameter nominal size m 990

14 Reinforced concrete pipes in trenches, 700mm diameter nominal size m 579

15 Reinforced concrete pipes in trenches, 800mm diameter nominal size m 432

Reinforced Concrete Pipe(cont'd)

1 Reinforced concrete pipes in trenches, 900mm diameter nominal size Ea 271

2 Reinforced concrete pipes in trenches, 1000mm diameter nominal size Ea 230

3 Reinforced concrete pipes in trenches, 1100mm diameter nominal size Ea 112

4 Reinforced concrete pipes in trenches, 1200mm diameter nominal size Ea 943

Page 1244: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Reinforced Concrete Manhole

Supply, installation and construction of reinforced concrete manholes including, but not

limited to excavation, backfilling, disposal of excavated materials, manhole covers, fittings

and accessories and all the necessary material needed to accomplish works according to

specifications and drawings for the following depth categories.

5 Depth to invert 1.5 m - 2 m Ea 27

6 Depth to invert 2 m - 2.5 m Ea 80

7 Depth to invert 2.5 m - 3 m Ea 51

8 Depth to invert 3 m - 3.5 m Ea 10

9 Depth to invert 3.5 m - 4 m Ea 16

10 Depth to invert 4 m - 4.5 m Ea 6

Catch Basin

Supply and construct reinforced concrete catch basins including excavation, backfilling,

disposal of excavated materials, concreting, waterproofing, frames and fittings and all the

necessary accessories for the following depth categories to complete the work as indicated

in the Contract drawings and mentioned in the Contract documents.

11 Depth to invert 1.5 m - 2 m Ea 409

Out fall

12 Construct reinforced concrete out fall including excavation, backfilling, disposal of Ea 2

excavated materials, concreting, waterproofing, frames and fittings and all the necessary

accessories for the following depth categories to complete the work as indicated in the

Contract drawings and mentioned in the Contract documents.

Page 1245: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Additional Items

The Contractor is to list here and price any items shown on the Drawings, mentioned in the

Specifications or required for the satisfactory completion of this section (Storm Drainage

System), but not mentioned here. Any such items not listed below shall be deemed to be

included

AMOUNT FOR STORM WATER DRAINAGE SYSTEM FORWARD TO SUMMARY

Page 1246: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Rate Amount

29.00 66,961.00

39.00 78,078.00

41.00 30,053.00

74.00 26,196.00

84.00 20,412.00

0.00 0.00

0.00 0.00

117.00 5,148.00

0.00 0.00

71.00 4,970.00

83.00 37,267.00

106.00 31,270.00

118.00 6,962.00

104.00 61,984.00

117.00 21,762.00

Page 1247: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

130.00 24,180.00

0.00 0.00

CF 415,243.00

BF 415,243.00

94.00 22,278.00

105.00 20,265.00

343.00 51,107.00

110.00 8,910.00

124.00 3,720.00

149.00 18,029.00

152.00 6,840.00

165.00 7,425.00

314.00 34,540.00

137.00 15,618.00

Page 1248: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

171.00 5,130.00

394.00 50,038.00

182.00 2,366.00

380.00 12,540.00

0.00 0.00

173.00 19,376.00

177.00 92,394.00

198.00 11,682.00

218.00 57,988.00

240.00 11,520.00

399.00 19,152.00

CF 470,918.00

BF 470,918.00

Page 1249: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

14.00 32,326.00

18.00 36,036.00

23.00 37,076.00

28.00 24,444.00

36.00 35,640.00

50.00 28,950.00

60.00 25,920.00

77.00 20,867.00

110.00 25,300.00

118.00 13,216.00

90.00 70,470.00

372.00 59,520.00

102.00 2,346.00

129.00 2,322.00

150.00 2,400.00

Page 1250: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 416,833.00

BF 416,833.00

174.00 1,740.00

200.00 2,000.00

227.00 2,270.00

254.00 2,540.00

282.00 2,820.00

311.00 3,110.00

341.00 3,410.00

372.00 3,720.00

85.00 170,170.00

Page 1251: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

65.00 150,085.00

105.00 169,260.00

122.00 106,506.00

147.00 145,530.00

169.00 97,851.00

186.00 80,352.00

CF 941,364.00

BF 941,364.00

225.00 60,975.00

290.00 66,700.00

336.00 37,632.00

381.00 359,283.00

Page 1252: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3542.00 95,634.00

4458.00 356,640.00

6431.00 327,981.00

7197.00 71,970.00

8457.00 135,312.00

10826.00 64,956.00

3348.00 1,369,332.00

3342.00 6,684.00

Page 1253: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 2,953,099.00

BF 2,953,099.00

US Dollar. 5,197,457.00

Page 1254: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Item Nr. Description Unit Qty

SITE DEVELOPMENT

SANITARY WASTE WATER COLLECTION SYSTEM

Trench Excavation

Trench excavation to a depth and the width as per specification and drawings. Works

include getting required permissions, secure safety guards, signboards, earthwork support,

consolidation of trench bottoms, trimming excavations, filling with compaction and filling

materials, disposal of surplus excavated materials and all requirements needed to complete

works of laying pipes. As indicated in the Contract drawings and mentioned in the Contract

documents.

1 Excavating trenches for pipe below ground level, pipe size ≤ 200 mm, average depth 1250 m 32

mm - 1500 mm

2 Ditto, for average depth 1500 mm - 1750 mm m 290

3 Ditto, for average depth 1750 mm - 2000 mm m 440

4 Ditto, for average depth 2000 mm - 2250 mm m 144

5 Ditto, for average depth 2250 mm - 2500 mm m 242

6 Ditto, for average depth 2500 mm - 2750 mm m 340

7 Ditto, for average depth 2750 mm - 3000 mm m 354

8 Ditto, for average depth 3000 mm - 3250 mm m 373

9 Ditto, for average depth 3250 mm - 3500 mm m 353

10 Ditto, for average depth 3500 mm - 3750 mm m 545

11 Ditto, for average depth 3750 mm - 4000 mm m 585

12 Ditto, for average depth 4000 mm - 4250 mm m 477

13 Ditto, for average depth 4250 mm - 4500 mm m 494

14 Ditto, for average depth 4500 mm - 4750 mm m 819

15 Ditto, for average depth 4750 mm - 5000 mm m 918

Page 1255: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Excavation (cont'd)

1 Ditto, for average depth 5000 mm - 5250 mm m 453

2 Ditto, for average depth 5250 mm - 5500 mm m 344

3 Excavating trenches for pipe below ground level, pipe nominal size 250 mm, average depth m 90

5250 mm - 5500 mm

4 Excavating trenches for pipe below ground level, pipe size nominal 300 mm, average depth m 8

5250 mm - 5500 mm

5 Ditto, for average depth 5500 mm - 5750 mm m 11

Pipe Bedding

Beds and surrounds with compacted soil, 150mm thick bed and 300mm thick surround as

indicated in the Contract drawings and mentioned in the Contract documents.

6 Beds and surroundings width 700 mm for pipe 200 mm diameter nominal size m 7,202

7 Beds and surroundings width 750 mm for pipe 250 mm diameter nominal size m 90

8 Beds and surroundings width 850 mm for pipe 300 mm diameter nominal size m 19

Page 1256: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Provisional quantities

Provisional quantities for beds and surrounding with concrete, 200 mm thick and 200mm

thick surround as indicated in the Contract drawings and mentioned in the Contract

documents.

9 Beds and surroundings width 700 mm for pipe 200 mm diameter nominal size m 720

10 Beds and surroundings width 750 mm for pipe 250 mm diameter nominal size m 9

11 Beds and surroundings width 850 mm for pipe 300 mm diameter nominal size m 2

Concrete Encasements

Concrete encasement for 160 mm uPVC diameter pipes including supply and compaction

with suitable equipment's and all requirements to complete work. As indicated in drawings

and Sewer network Specifications

12 Concrete encasements width 650 mm for pipe 160 mm diameter nominal size m 4,925

Additional Items

The Contractor is to list here and price any items shown on the Drawings, mentioned in the

Specifications or required for the satisfactory completion of this section, but not mentioned

here. Any such items not listed below shall be deemed to be included.

Distribution Pipes

Supply and installation of vitrified clay pipes with standard strength, Work includes supply,

Page 1257: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

installation and protection for pipes and fittings, thrust blocks, leakage tests, operation

surveying works and all necessary works as per specifications for the following pipe

diameters. As indicated in drawings and Sewer network Specifications

1 200 mm diameter m 7,202

2 250 mm diameter m 90

3 300 mm diameter m 19

Precast Concrete Manholes

Supply and construct circular type precast manholes with internal diameter of 1.2 m

including excavating backfilling, internal and external coating, steps and covers according to

specifications and drawings and surface reinstatement and all requirements to complete

the works for the following depth categories: As indicated in drawings and Sewer network

Specifications

4 Depth up to 3m Ea 41

5 Depth greater than 3m and less than or equal to 4m Ea 39

6 Depth greater than 4m and less than or equal to 5m Ea 72

7 Depth greater than 5m and less than or equal to 6m Ea 28

Supply and construct circular type precast backdrop manholes with depth up to 5.0 m and

the item shall include all works and necessary material needed to accomplish works

according to specifications and drawings for the following depth categories:

8 Depth up to 1.5m Ea 4

9 Depth greater than 1.5m Ea 5

Cleanouts

10 Supply and construct cleanouts from VC pipes and the item includes all works, material and Ea 2

necessary connections needed to finish work according to specifications and drawings for

the following diameters: As indicated in drawings and Sewer network Specifications

11 Supply and construct cleanouts from uPVC pipes (160mm) and the item includes all works, Ea 170

material and necessary connections needed to finish work according to specifications and

drawings for the following diameters: As indicated in drawings and Sewer network

Specifications

House Connections

Supply and construct sewer connections to the manholes according to specifications and

Page 1258: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

drawings. Work shall include direct connections to manholes excavating, backfilling,

bedding, surfaces reinstatement, removal of excavated material, getting the permissions,

secure the site with safety guards and to supply uPVC pipes, and accessories Class 5 with

NP16 bars including all connection works for the following diameters: As indicated in

drawings and Sewer network Specifications

12 160 mm diameter pipe Ea 170

Supply and construct sewer connections to the pipes including all works as mentioned in

the item no 12 for the following diameters:

13 160 mm diameter pipe Ea 170

Inspection Chambers

1 Supply and construct inspection chambers on sewer lines and work shall include all

excavation works, backfilling, concrete, connections and surfaces reinstatement as per

specifications and drawings and all requirements to finish work. As indicated in drawings

and Sewer network Specifications

160 mm diameter pipe Ea 388

Sewage Treatment Plant

Page 1259: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Wastewater Treatment Plant by biological membranes

Lump sum supply, construction and installation and commissioning of the sewage LS 1

treatment plant using biological membrane technology at average capacity 1109 m3/day

(peak flow 141.84 m3/h) .The item includes operation, maintenance and training of labour

for one year from the date of preliminary handover . The plant include but not limited to

inlet works (inlet chamber, fine screen and vortex grit chamber), aerated balance tank with

submerged aerator, aeration tank with biological membranes including modules

membranes and treated water pump system, backwash system and the excess sludge

withdrawal system, air blowers. The item also includes sludge holding tank and mixer,

mechanical sludge dewatering units complete with all necessary polymer feeding and

pumps, the supernatant drainage network to the inlet lift station, the treated water

chlorination system. The item includes chlorination building, administration building, etc....

The item also includes all the construction works, civil, electrical and mechanical plant with

supply and installation of all equipment, piping and pumps and valves and air blower,

and instrumentation as well as the motor control centre MCC and all the works of lighting

and wiring, cables and electrical equipment and fire alarm system. The works include all

plumbing and service networks (water - sewage - etc. ..), all necessary site works, and the

HVAC of buildings. The item includes all necessary works to complete the work according to

the performance specifications and drawings

SANITARY - LIFT STATION

03 00 00 - CONCRETE

Notwithstanding the Provisions of the Standard Method of Measurement of Building Works

Seventh Edition, 1988 (SMM7) the following concrete works are measured m3/m including

reinforcement bars and formworks. The Contractor is to include for costs of reinforcement

and formwork with concrete works. No additional charge or cost for reinforcement and

formwork separately will be entertained due to lack or want of knowledge.

All concrete works herein shall be completed in full compliance with the Drawings nr UBSTP-

S101, UB-STP-S401 and Specification.

03 11 13 Structural Cast-in-Place Concrete Forming

1 Plain Concrete 20 Mpa, for blinding Beds, Thickness ≤ 150mm, poured against the m3 4

compacted soil, as stated in the Structural Notes and Specification.

Page 1260: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

03 31 00 Structural Concrete

2 Reinforced concrete 35 MPa, foundations (Raft), 350mm thick including 200 x 200 x 200mm m3 14

sump pit (kind, quality, curing details etc. as stated in the Structural Notes and Specification.

3 Reinforced concrete 35 MPa substructure walls; kind, quality, curing details etc. as stated in m3 77

the Structural Notes and Specification.

4 Reinforced concrete 35 MPa for superstructure slabs, thickness 200mm, (kind, quality, m3 1

curing details etc. as stated in the Structural Notes and Specification.

03 37 13 Shotcrete / block wall

5 Shotcrete for substructure under ground pump room wall m2 205

(200mm thick Block CMU as per Dwg. No. UB-STP-S401).

03 53 00 Concrete Topping

1 Sand cement/concrete screed for protection screed for substructure, width > 300mm, m2 40

(thickness, kind, quality, composition, mix, materials, nature of base, method of

construction, layout and treatments, thermal insulation, moisture resistant treatment,

method of jointing, etc. as per the Drawings and Specification).

03 00 00 - Concrete

Additional Items

2 The Contractor is to list here and price any items shown on the Drawings, mentioned in the

Specifications or required for the satisfactory completion of this section, but not mentioned

here. Any such items not listed below shall be deemed to be included.

Page 1261: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

05 00 00 METALS

All metal works herein shall be completed full incompliance with the Drawings UB-STPS101,

UB-STP-S401 and Specification.

05 70 00 Decorative Metal

1 Supply and fix access opening with aluminium cover and frame, 1000mm x 900mm at wet nr 1

well, kind, quality, fittings, fixtures, accessories as shown on Drawings and as per

Specification.

2 Supply and fix access opening with aluminium cover and frame, 1200mm x 650mm at wet nr 1

well, kind, quality, fittings, fixtures, accessories as shown on Drawings and as per

Specification.

3 Supply and fix access opening with aluminium cover frame, 1000mm x 900mm at valve nr 1

chamber, kind, quality, fittings, fixtures, accessories as shown on Drawings and as per

Specification.

4 Supply and fix access opening with aluminium cover frame, 1000mm x 900mm at manhole, nr 1

kind, quality, fittings, fixtures, accessories as shown on Drawings and as per Specification.

5 Supply and fix access opening with aluminium multi sectional cover frame, 5800mm x nr 1

2100mm, kind, quality, fittings, fixtures, accessories as shown on Drawings and as per

Specification.

6 Supply and fixed GRP ladder rung 6000 mm height, 300mm spacing including mechanical nr 1

support as per the Drawing and Specification

7 Supply and fix 50mm x 50mm, stainless steel guide rails, kind, quality, fittings, fixtures, nr 4

accessories as shown on Drawings and as per Specification.

05 00 00 Metals

Additional Items

8 The Contractor is to list here and price any items shown on the Drawings, mentioned in the

Specifications or required for the satisfactory completion of this section, but not mentioned

here. Any such items not listed below shall be deemed to be included.

Page 1262: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

07 00 00 THERMAL AND MOISTURE PROTECTION

07 10 00 Damp proofing and Waterproofing

Substructure Waterproofing

All works herein shall be completed in full incompliance with the Drawings nr UB-STP-S101,

UB-STP-S401 and Specification.

1 Waterproofing works for substructure 250mm PVC water stop, vertical surface, width > m 34

300mm(kind, quality, method of application, thickness as per the Drawings and

Specification).

2 Waterproofing works for substructure with two 4 mm layer of water proofing membrane, m2 244

horizontal surface, width > 300mm(kind, quality, method of application, thickness as per

the Drawings and Specification).

07 00 00 Thermal and Moisture Protection

Additional Items

3 The Contractor is to list here and price any items shown on the Drawings, mentioned in the

Specifications or required for the satisfactory completion of this section, but not mentioned

here. Any such items not listed below shall be deemed to be included.

26 00 00 - ELECTRICAL

All items hereunder to be described with information such as appropriate to the

procurement , type, kind, quality, size, method of fixing , specified codes of practice

Page 1263: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

26 05 19 Low Voltage Electrical Power Conductors and cables

All items hereunder to be described with information such as type, kind, number of cores,

armoring and sheathings, method of fixing, specified codes of practice, etc. as per the

Drawings and Specification).

1 3C 16mm² + 16mm² CU/XLPE/PVC + CU/PVC for submersible pump 1 & 2 m 30

2 3C 10mm² + 10mm² CU/XLPE/PVC + CU/PVC for odour control unit m 15

3 3C 6mm² + 6mm² CU/XLPE/PVC + CU/PVC for lighting power panel m 15

4 3C 4mm² + 4mm² CU/XLPE/PVC + CU/PVC for lighting and power at control room m 18

Wiring Devices

5 One way one gang switch nr 1

Power Outlets

6 Duplex receptacle outlet, 230V, 20A normal power supply nr 2

7 Disconnection switch, NEMA-4X nr 4

Lighting

8 Pendant mounted with a suspended rod luminare with open end wrap around diffuser, 2 No nr 1

of flourescent 36W/220V60Hz lamps, electric ballast & clear prismatic patteren (C2 type)

Panel boards

All items hereunder to be described with information such as type, kind, rated capacity,

method of fixing, cores reference to Specification, fuses, backgroung,specified codes of

practice, etc. as per the Drawings and Specification).

Programmable Logic Control Unit (PLC)

1 Supply and install control panel system (KIOSK) for sanitary lift station system as per the Item 1

drawing and Engineer's specification

Page 1264: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Submersible Sump Pumps

2 Submersible sewage pump set, pump capacity 47 L/s, pump head 20 m, 15 Kw Set 2

power, including cable strapped with stainless steel chain as per the drawing and

Engineer's specification

26 00 00 - Electrical

Additional Items

3 The Contractor is to list here and price any items shown on the Drawings, mentioned in the

Specifications or required for the satisfactory completion of this section (Storm Drainage

System), but not mentioned here. Any such items not listed below shall be deemed to be

included

31 00 00 EARTHWORK

All works herein shall be completed in full compliance with the Drawings nr UB-STP-S101,

UB-STP-S401 and Specification.

31 10 00 Site Clearing

1 Site preparation, clearing site vegetation m2 90

31 23 16 Excavation

2 Excavating top soil for preservation, average depth 150mm. m2 40

3 Excavating pits for valve chamber, depth of excavation from 2 - 4m m3 42

4 Excavating pits for man hole, depth of excavation from 6 - 8m m3 43

Page 1265: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

5 Excavating pits for wet well, depth of excavation from 8 - 10m m3 137

31 23 23.13 Backfill

6 Filling to excavations, average thickness > 0.25 m, arising from excavated materials, all fill m3 24

shall be compacted to 75% relative density for cohesion-less soils as per ASTM D4254/ASTM

D4293 or 95% maximum density as determined by ASTM D698 for cohesive material, as per

the Drawings and Specifications).

31 23 23.23 Compaction

7 Surface treatments, compacting bottom of excavation, compaction to meet 85% of relative m2 40

density for cohesion-less soils or 95% maximum density as determined by ASTM D1557 for

cohesive materials per the Drawings and Specifications)

31 23 16.26 Rock Removal

8 Disposal of excavated material, off site as stated in the Specification. m3 198 m3 198

31 31 16 Termite Control

10 Termite control for the horizontal surface (method and type of treatment as per the m2 40

Drawings and Specifications)

11 Termite control for vertical surface (method and type of treatment as per the Drawings and m2 237

Specifications)

Additional Items

The Contractor is to list here and price any items shown on the Drawings, mentioned in the

Specifications or required for the satisfactory completion of this section (Storm Drainage

System), but not mentioned here. Any such items not listed below shall be deemed to be

included

Page 1266: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

32 00 00 EXTERIOR IMPROVEMENTS

32 14 13 Precast Concrete Unit Paving

1 Precast Concrete Unit Paving for external floor, level or to falls only ≤ 15° from horizontal, m2 62

fixed compacted soil (thickness, kind, quality, size, nature of base, method of construction

etc. as per the Drawings and Specification).

2 Chain link fence; consisting of metal post and pvc coated wire mesh; the height to be m 39

detemined on site as per Engineer's specification

3 Double leaf chain link gate to the fence; the height to be detemined on site as per nr 1

Engineer's specification

Additional Items

The Contractor is to list here and price any items shown on the Drawings, mentioned in the

Specifications or required for the satisfactory completion of this section, but not mentioned

here. Any such items not listed below shall be deemed to be included.

33 00 00 UTILITIES

33 30 00 Sanitary Sewerage Utilities

1 Ductile iron pipe; 200 mm m 35

2 Ductile iron pipe; 150 mm m 3

3 Gate valve; 200 mm nr 4

Page 1267: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

4 Non return valve; 200 mm nr 2

5 Flange adaptor; 200 mm nr 3

6 Flexible coupling; 200 mm nr 8

7 Dismantling joint; 200 mm nr 1

8 Quick release fit hose connection; 100 mm nr 1

9 Quick release coupler; 200 mm nr 1

10 Flow meter; 200 mm nr 1

11 100mm dia UPVC drain pipe m 6

12 100mm vent pipe with vent cap nr 2

13 Motorized penstock; 200mm x 200 mm nr 1

14 Supply, installation, testing, adjusting, balancing, and guarantee Activated Carbon odour Item 1

system including operation, maintenance, tools & spare parts as per the specification, all

piping works inside the System , valves, tees, elbows, flexible connections, control panel,

electrical connections, fittings, Fan, Instrumentation and all necessary to complete the work

as per the specification, drawings and Engineer's instructions.

Additional Items

15 The Contractor is to list here and price any items shown on the Drawings, mentioned in the

Specifications or required for the satisfactory completion of this section, but not mentioned

here. Any such items not listed below shall be deemed to be included.

Total for SANITARY SEWAGE SYSTEM TO SUMMARY

Page 1268: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Amount

23.00 736.00

27.00 7,830.00

31.00 13,640.00

58.00 8,352.00

66.00 15,972.00

73.00 24,820.00

80.00 28,320.00

88.00 32,824.00

95.00 33,535.00

103.00 56,135.00

266.00 155,610.00

283.00 134,991.00

300.00 148,200.00

314.00 257,166.00

334.00 306,612.00

Page 1269: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 1,224,743.00

BF 1,224,743.00

351.00 159,003.00

369.00 126,936.00

378.00 34,020.00

398.00 3,184.00

417.00 4,587.00

24.00 172,848.00

36.00 3,240.00

40.00 760.00

Page 1270: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

113.00 81,360.00

125.00 1,125.00

144.00 288.00

102.00 502,350.00

CF 2,314,444.00

BF 2,314,444.00

Page 1271: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

46.00 331,292.00

60.00 5,400.00

135.00 2,565.00

4662.00 191,142.00

5551.00 216,489.00

6389.00 460,008.00

7807.00 218,596.00

3748.00 14,992.00

4390.00 21,950.00

331.00 662.00

331.00 56,270.00

Page 1272: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

189.00 32,130.00

189.00 32,130.00

CF 3,898,070.00

BF 3,898,070.00

1771.00 687,148.00

CF 4,585,218.00

BF 4,585,218.00

Page 1273: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2040134.00 2,040,134.00

CF 6,625,352.00

BF 6,625,352.00

188.00 752.00

Page 1274: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

434.00 6,076.00

695.00 53,515.00

648.00 648.00

47.00 9,635.00

CF 6,695,978.00

BF 6,695,978.00

17.00 680.00

Page 1275: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 6,696,658.00

BF 6,696,658.00

493.00 493.00

583.00 583.00

493.00 493.00

493.00 493.00

5054.00 5,054.00

1355.00 1,355.00

678.00 2,712.00

Page 1276: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 6,707,841.00

BF 6,707,841.00

16.00 544.00

36.00 8,784.00

CF 6,717,169.00

BF 6,717,169.00

Page 1277: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

15.00 450.00

12.00 180.00

8.00 120.00

6.00 108.00

10.00 10.00

19.00 38.00

685.00 2,740.00

128.00 128.00

CF 6,720,943.00

BF 6,720,943.00

included in item 2 below

Page 1278: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

48517.00 97,034.00

CF 6,817,977.00

BF 6,817,977.00

2.00 180.00

3.00 120.00

8.00 336.00

8.00 344.00

Page 1279: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

8.00 1,096.00

12.00 288.00

3.00 120.00

4.00 792.00

1.00 40.00

1.00 237.00

Page 1280: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 6,821,530.00

BF 6,821,530.00

26.00 1,612.00

120.00 4,680.00

2591.00 2,591.00

CF 6,830,413.00

BF 6,830,413.00

818.00 28,630.00

805.00 2,415.00

1642.00 6,568.00

Page 1281: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1558.00 3,116.00

393.00 1,179.00

558.00 4,464.00

393.00 393.00

682.00 682.00

1095.00 1,095.00

1920.00 1,920.00

29.00 174.00

331.00 662.00

3097.00 3,097.00

2065.00 2,065.00

6,886,873.00

Page 1282: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Item Nr. Description Unit

SITE DEVELOPMENT

IRRIGATION WATER SYSTEM

Trench Excavation

1 Trench excavation to a depth of 1.5 m and the width as per specification and drawings. m3

Works include getting required permissions, secure safety guards, signboards, excavating,

soil support dewatering and removing excavated material and all requirements needed to

complete works of laying pipes. As indicated in the Contract drawings and mentioned in the

Contract documents.

Pipe Bedding

2 2 Granular bedding and initial backfill including supply, and compaction with suitable m3

equipment's and all requirements to complete work. As indicated in the Contract drawings

and mentioned in the Contract documents.

Backfilling

3 3 Backfilling to finish ground level with approved selected excavated material from trench or m3

borrowed from outside including supply, warning tape and compaction with suitable

equipment's and all requirements to complete work. As indicated in Contract drawings and

mentioned in the Contract documents

Disposal

4 Disposal of surplus material to authorised tipping or as directed by Engineer or Sewer m3

network Specifications

Valves and Accessories

Supply and installation of solenoid valves including supply and installation of all valve

accessories, fittings, excavations, backfilling, disposal of excavated materials and concrete

supports to complete the work as indicated in the Contract drawings and mentioned in the

Contract documents

5 Solenoid valve; 25 mm with pressure regulator Ea

6 Solenoid valve; 40 mm with pressure regulator Ea

7 Solenoid valve;50 mm with pressure regulator Ea

Supply and installation of isolation gate valves including supply and installation of all valve

accessories, fittings, excavations, backfilling, disposal of excavated materials and concrete

supports to complete the work as indicated in the Contract drawings and mentioned in the

Contract documents

8 Isolation Gate Valve; 100 mm Ea

Page 1283: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

9 Isolation Gate Valve; 150 mm Ea

10 Isolation Gate Valve; 200 mm Ea

11 Isolation Gate Valve; 250 mm Ea

Supply and installation of brass gate valves including supply and installation of all valve

accessories, fittings, excavations, backfilling, disposal of excavated materials and concrete

supports to complete the work as indicated in the Contract drawings and mentioned in the

Contract documents

12 Brass gate valve; 25 mm Ea

13 Brass gate valve; 40 mm Ea

14 Brass gate valve; 50 mm Ea

IRRIGATION WATER SYSTEM (Cont'd)

Supply and installation of quick coupling valve including supply and installation of all valve

accessories, fittings, excavations, backfilling, disposal of excavated materials and concrete

supports to complete the work as indicated in the Contract drawings and mentioned in the

Contract documents

1 Quick coupling valve; 20 mm Ea

2 Quick coupling key Ea

3 Supply and installation of air vents (50 mm) including all necessary fittings and accessories Ea

to complete the work as indicated in the contract drawings nr RGC_IR_C915and mentioned

in the contract documents

4 Supply and installation of decode Controller with cabinet and pedestal 200 station including Ea

all necessary fittings and accessories to complete the work as indicated in the contract

drawings and mentioned in the contract documents

5 Supply and installation of Valve boxes rectangular including all necessary fittings and Ea

accessories to complete the work as indicated in the contract drawings and mentioned in

the contract documents

6 Supply and installation of Valve box round including all necessary fittings and accessories to Ea

complete the work as indicated in the contract drawings and mentioned in the contract

documents

7 Supply and installation of field decoder including all necessary fittings and accessories to Ea

Page 1284: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

complete the work as indicated in the contract drawings and mentioned in the contract

documents

8 Supply and installation of pop-up spray sprinkler 1.2 m radius, 12 mm inlet including all Ea

necessary fittings and accessories to complete the work as indicated in the contract

drawings and mentioned in the contract documents

9 Supply and installation of pop-up spray sprinkler 1.8 m radius, 12 mm inlet including all Ea

necessary fittings and accessories to complete the work as indicated in the contract

drawings and mentioned in the contract documents

10 Supply and installation of pop-up spray sprinkler 2.4 m radius, 12 mm inlet including all Ea

necessary fittings and accessories to complete the work as indicated in the contract

drawings and mentioned in the contract documents

11 Supply and installation of pop-up spray sprinkler 3.0 m radius, 12 mm inlet including all Ea

necessary fittings and accessories to complete the work as indicated in the contract

drawings and mentioned in the contract documents

12 Supply and installation of pop-up spray sprinkler 3.5 m radius, 12 mm inlet including all Ea

necessary fittings and accessories to complete the work as indicated in the contract

drawings and mentioned in the contract documents

13 Supply and installation of pop-up spray sprinkler 4.5 m radius, 12 mm inlet including all Ea

necessary fittings and accessories to complete the work as indicated in the contract

drawings and mentioned in the contract documents

14 Supply and installation of pop-up spray sprinkler 5.5 m radius, 12 mm inlet including all Ea

necessary fittings and accessories to complete the work as indicated in the contract

drawings and mentioned in the contract documents

15 Supply and installation of pop-up rotor sprinkler 11 m radius, 20 mm inlet including all Ea

necessary fittings and accessories to complete the work as indicated in the contract

drawings and mentioned in the contract documents

16 Supply and installation of pop-up rotor sprinkler 13.5 m radius, 20 mm inlet including all Ea

necessary fittings and accessories to complete the work as indicated in the contract

drawings and mentioned in the contract documents

IRRIGATION WATER SYSTEM (Cont'd)

Supply and installation of swing joint including all necessary fittings and accessories to

Page 1285: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

complete the work as indicated in the contract drawings and mentioned in the contract

documents

1 12 mm diameter Ea

2 20 mm diameter Ea

3 Supply and installation of PC bubbler, 1 GPM including all necessary fittings and accessories Ea

to complete the work as indicated in the contract drawings and mentioned in the contract

documents

4 Supply and laying of drip line, 0.9 GPH flow, 450 mm spacing including all necessary m

accessories to complete the work as indicated in the contract drawings and mentioned in

the contract documents

5 Supply and laying of irrigation decoder cable including all necessary accessories to complete m

the work as indicated in the contract drawings and mentioned in the contract documents

6 Supply and installation of wire connector including all necessary accessories to complete the Ea

work as indicated in the contract drawings and mentioned in the contract documents

Distribution Pipes

Laying of Unplasticized polyvinyl Chloride Pipe (uPVC), Class IV in trenches including supply

of pipes, pipe fittings and accessories, installation, and protection for pipes and fittings,

thrust blocks, leakage tests, operation surveying works and all necessary works as per

specifications for the following pipe diameters. As indicated in Contract drawings and

mentioned in the Contract documents

7 25 mm diameter m

8 32 mm diameter m

9 50 mm diameter m

10 63 mm diameter m

11 75 mm diameter m

Laying of Unplasticized polyvinyl Chloride Pipe (uPVC), Class V in trenches including supply of

pipes, pipe fittings and accessories, installation, and protection for pipes and fittings, thrust

blocks, leakage tests, operation surveying works and all necessary works as per

specifications for the following pipe diameters. As indicated in Contract drawings and

mentioned in the Contract documents

12 75 mm diameter m

13 110 mm diameter m

Page 1286: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

14 160 mm diameter m

15 200 mm diameter m

16 280 mm diameter m

17 Supply and fix 100 mm uPVC washout including all necessary accessories to complete the Ea

work as indicated in the contract drawings nr RGC_IR_C916 and mentioned in the contract

documents

AMOUNT FOR IRRIGATION SYSTEM TO SUMMARY

IRRIGATION WATER STORAGE TANK AND PUMP HOUSE

03 00 00 - CONCRETE

Notwithstanding the Provisions of the Standard Method of Measurement of Building Works

Seventh Edition, 1988 (SMM7) the following concrete works are measured m3/m including

reinforcement bars and formworks. The Contractor is to include for costs of reinforcement

and formwork with concrete works. No additional charge or cost for reinforcement and

formwork separately will be entertained due to lack or want of knowledge.

All concrete works herein shall be completed in full compliance with Contract drawings nr

UB-RP-S101,S201, S401 and Specification.

03 11 13 Structural Cast-in-Place Concrete Forming

1 Plain Concrete 20 Mpa, for blinding Beds, Thickness ≤ 150mm, poured against the m3

compacted soil, as stated in the Structural Notes and Specification.

03 31 00 Structural Concrete

2 Reinforced concrete 35 MPa, foundations (footings); kind, quality, curing details etc. as m3

stated in the Structural Notes and Specification.

3 Reinforced concrete 35 MPa, foundations (raft); kind, quality, curing details etc. as stated in m3

the Structural Notes and Specification.

4 Reinforced concrete 35 MPa for ground beams; kind, quality, curing details etc. as stated in m3

the Structural Notes and Specification.

5 Reinforced concrete 35 MPa for slab on grade; thickness 200 mm, poured against the m3

Page 1287: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

compacted soil; kind, quality, curing details etc. as stated in the Structural Notes and

Specification.

6 Reinforced concrete for substructure columns, 35 MPa up to slab on grade and top slab; m3

kind, quality, curing details etc. as stated in the Structural Notes and Specification.

7 Reinforced concrete for substructure walls, 35 MPa up to top slab; kind, quality, curing m3

details etc. as stated in the Structural Notes and Specification.

1 Reinforced concrete 35 MPa for substructure top slab, thickness 300mm; kind, quality, m3

curing details etc. as stated in the Structural Notes and Specification.

2 Reinforced concrete 35 MPa for superstructure slabs, thickness 250mm; kind, quality, curing m3

details etc. as stated in the Structural Notes and Specification.

2 Reinforced concrete 35 MPa for superstructure for generator pad, thickness 250mm; kind, m3

quality, curing details etc. as stated in the Structural Notes and Specification.

3 Reinforced concrete 35 MPa superstructure beams; kind, quality, curing details etc. as m3

stated in the Structural Notes and Specification.

4 Reinforced concrete 35 MPa superstructure columns; kind, quality, curing details etc. as m3

stated in the Structural Notes and Specification.

5 Reinforced concrete 35 Mpa for parapet walls 200mm thickness; kind, quality, curing details m3

etc. as stated in the Structural Notes and Specification.

03 30 53 - Miscellaneous Cast-in-situ Concrete

1 200mm wide x 200mm high reinforced concrete 35 Mpa for lintel m 20 m

03 53 00 Concrete Topping

2 Sand cement/concrete screed for floors, width > 300mm, (thickness, kind, quality, m2

composition, mix, materials, nature of base, method of construction, layout and treatments,

thermal insulation, moisture resistant treatment, method of jointing, etc. as per the

Page 1288: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Drawings and Specification).

3 Sand cement/concrete screed for roof with A 252 mesh, width > 300mm, (thickness, kind, m2

quality, composition, mix, materials, nature of base, method of construction, layout and

treatments, thermal insulation, moisture resistant treatment, method of jointing, etc. as per

the Drawings and Specification).

Additional Items

4 The Contractor is to list here and price any items shown on the Drawings, mentioned in the

Specifications or required for the satisfactory completion of this section, but not mentioned

here. Any such items not listed below shall be deemed to be included.

04 00 00 - Masonry

All Masonry works herein shall be completed full incompliance with the Drawings nr UB-IRRA00,

A001,A002,A101,A201,A202,A501,A701,A801,A901 and Specification.

04 22 00 - Concrete Unit Masonry

Internal walls

1 200 mm thick brick wall, internal vertical brick work (kind, quality and size of blocks, type of m2

bond, mix of mortar etc. to be included as per the details and Specification )

External walls

2 200 mm thick brick wall, external vertical brick work (kind, quality and size of blocks, type of m2

bond, mix of mortar etc. to be included as per the details and Specification )

04 00 00 - Masonry

Additional Items

3 The Contractor is to list here and price any items shown on the Drawings, mentioned in the

Specifications or required for the satisfactory completion of this section, but not mentioned

here. Any such items not listed below shall be deemed to be included.

Page 1289: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

05 00 00 METALS

All metal works herein shall be completed full incompliance with Contract drawings and

Specification.

05 70 00 Decorative Metal

1 Supply and fix galvanized steel ladder 6,400 mm high 475 mm width with safety cage nr

including mechanical support as per the Drawing and Specification

2 Supply and fix stainless steel steps, 400 mm width including mechanical support as per the nr

Drawings and Specifications

3 Supply and fix 900 mm x 900 mm steel cover and frame for opening at irrigation water nr

storage tank, kind, quality, fittings, fixtures, accessories as shown on Drawings and as per

Specification.

4 Supply and fix 2,000 mm x 800 mm steel cover and frame for opening at irrigation water nr

storage tank, kind, quality, fittings, fixtures, accessories as shown on Drawings and as per

Specification.

5 Supply and fix 1,200 mm x 1,200 mm steel cover and frame for opening at sump pit, kind, nr

quality, fittings, fixtures, accessories as shown on Drawings and as per Specification.

05 00 00 Metals

Additional Items

6 The Contractor is to list here and price any items shown on the Drawings, mentioned in the

Specifications or required for the satisfactory completion of this section, but not mentioned

here. Any such items not listed below shall be deemed to be included.

As per Question and Answer No (393)

6.1 Heavy duty steel frame & cover for fuel tank 600 x 600 mm nr

07 00 00 THERMAL AND MOISTURE PROTECTION

Page 1290: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

07 10 00 Damp proofing and Waterproofing

Substructure Waterproofing

All works herein shall be completed in full incompliance with the Drawings and

Specification.

1 Waterproofing works for substructure with two layers of approved waterproofing m2

membrane for horizontal surface, width > 300mm, (kind, quality, method of fixing, thickness

as per the Drawings and Specification).

2 Waterproofing works for substructure with two layers of approved waterproofing m2

membrane for vertical surface, width > 300mm, (kind, quality, method of fixing, thickness as

per the Drawings and Specification).

3 Waterproofing works for substructure with two coats of bitumen paint, vertical surface, m2

width > 300mm(kind, quality, method of application, thickness as per the Drawings and

Specification).

4 Waterproofing works for substructure with two coats of bitumen paint, horizontal surface, m2

width > 300mm, (kind, quality, method of fixing, thickness as per the Drawings and

Specification).

5 Waterproofing works for substructure with non-toxic 1000 micron thick epoxy polysulphide m2

coat tank for vertical surface, width > 300mm, (kind, quality, method of fixing, thickness as

per the Drawings and Specification).

6 Waterproofing works for substructure with non-toxic 1000 micron thick epoxy polysulphide m2

coat tank for horizontal surface, width > 300mm, (kind, quality, method of fixing, thickness

All works herein shall be completed in full incompliance with the Drawings and Specification.

7 Waterproofing membrane with geotextile layer on top for roof horizontal surface, width > m2

300mm, (kind, quality, method of fixing, thickness as per the Drawings and Specification) -

Roof

8 100mm thick rigid insulation for water proofing works at roof, horizontal surface, width > m2

300mm, (kind, quality, method of fixing, thickness as per the Drawings and Specification)

Additional Items

9 The Contractor is to list here and price any items shown on the Drawings, mentioned in the

Specifications or required for the satisfactory completion of this section, but not mentioned

here. Any such items not listed below shall be deemed to be included.

Page 1291: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

08 00 00 OPENINGS

All works herein shall be completed in full compliance with the Doors & Windows Schedule

Drawings nr UB-IRR-A101,201,202,501,701,801,901 and Specification.

Note: Notwithstanding the Provisions of the Standard Method of Measurement, door sets Note

including doors, frames, vision panels, decoration and ironmongery have been measured as

a composite item and the Contractor should make due reference to the drawings and

specification. No claim for lack or want of knowledge will be entertained

08 13 00 - Metal Doors

1 D1; 2000 mm width x 2,200 mm height 2 Hr. fire rated, hollow core double steel door and nr

metal frame, painted , stainless steel lock, heavy duty door hinges; as shown in the contract

drawings, specification and mentioned in the contract documents

2 D2; 2,300 mm width x 2,200 mm height 2 Hr. fire rated, louver steel door and metal frame; nr

painted, stainless steel lock, heavy duty door hinges ;as shown in the Contract drawings and

mentioned in the Contract documents

3 D3; 1000 mm width x 2,200 mm height 2 Hr. fire rated, single steel door and metal frame; nr

painted, stainless steel lock, heavy duty door hinges ;as shown in the Contract drawings and

mentioned in the Contract documents

08 51 13 Aluminium Windows

4 W1; 2000 mm width x 600 mm height Powder coated aluminium frame awning window nr

including 12 mm thick tinted tempered glass and weather tight strip to complete the work

as shown on the Contract drawings and mentioned in the Contract documents

5 W2; 4,100 mm width x 3,200 mm height aluminium frame exhaust grille window with nr

movable aluminium louver as shown on the Contract drawings and mentioned in the

Contract documents

Page 1292: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

OPENINGS (Cont'd)

08 00 00 Openings

Additional Items

1 The Contractor is to list here and price any items shown on the Drawings, mentioned in the

Specifications or required for the satisfactory completion of this section, but not mentioned

here. Any such items not listed below shall be deemed to be included.

09 00 00 - FINISHES

All works herein shall be completed full incompliance with the schedule Drawings nr UB-IRR-

A101,201,202,501,701,801,901 and Specification.

09 24 00 Cement Plastering

Internal walls

1 Plastering for internal walls to receive paint finish, width > 300mm, (thickness, kind, quality, m2

composition, mix materials, nature of base, method of construction, layout and

treatments, thermal insulation, moisture resistant treatment, method of jointing, etc. as per

Page 1293: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

the Drawings and Specification).

External walls

2 Self coloured rendering ( pre coloured mineral wall coating) for external walls, width > m2

300mm, (thickness, kind, quality, composition, mix materials, nature of base, method of

construction, layout and treatments, thermal insulation, moisture resistant treatment,

method of jointing, etc. as per the Drawings nr UB-IRR-A201,202,501,,701,801,901 and

Specification.

09 30 13 Ceramic Tiling

Floor Tiling

3 Slip resistant epoxy flooring, level or to falls only ≤ 15° from horizontal, fixed over cement m2

sand screed (screed measured separately), thickness, method of construction, layout and

treatments, method of jointing, etc. as per the Drawings nr UB-IRRA201,

A202,A501,701,801,901 and Specification.

Skirting

4 Terrazzo tile skirting 150mm height for roof, vertical, fixed over cement sand screed m

(thickness, kind, quality, size, nature of base, method of construction, layout and

treatments, thermal insulation, moisture resistant treatment, method of jointing etc. as per

the Drawings and Specification)

FINISHES (Cont'd)

09 50 00 Ceilings

Ceiling -Painting

1 Painting on exposed for ceiling, girth ≤ 300mm, (kind, quality of materials, preparatory m2

works, priming coat (1nr), undercoats (1nr), finishing coat (1nr), method of application, etc.

as per the Drawings and Specification).

2 Emulsion painting on exposed for ceiling, girth ≤ 300mm, (kind, quality of materials, m2

preparatory works, priming coat (1nr), undercoats (1nr), finishing coat (1nr), method of

application, etc. as per the Drawings and Specification).

Roof painting

Page 1294: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3 Thermoplastic polyolefin on exposed for roof slab, girth ≤ 300mm, (kind, quality of m2

materials, preparatory works, method of application, etc. as per the Drawings and

Specification).

09 91 00 - Painting

Wall -Painting

4 Painting for walls, girth > 300mm, (kind, quality of materials, painted on cement plastering, m2

preparatory works, priming coat, undercoats, finishing coat method of application, etc. as

per the Drawings nr UB-IRR-A201, 501,701,801,901 and Specification).

5 Painting on exposed for roof parapet wall, girth ≤ 300mm, (kind, quality of materials, m2

preparatory works, method of application, etc. as per the Drawings and Specification).

Additional Items

6 The Contractor is to list here and price any items shown on

the Drawings, mentioned in the Specifications or required for

the satisfactory completion of this section, but not mentioned

here. Any such items not listed below shall be deemed to be

included.

10 00 00 SPECIALTIES

10 44 16.13 Portable Fire Extinguishers

All items hereunder to be described with kind, quality, size, method of fixing , etc. as per the

Drawings nr UB-STP-M201,M202 and Specification).

1 Supply & install Portable Fire Extinguishers (10 Kg CO₂) nr

10 00 00 Specialties

Additional Items

2 The Contractor is to list here and price any items shown on the Drawings, mentioned in the

Specifications or required for the satisfactory completion of this section, but not mentioned

here. Any such items not listed below shall be deemed to be included.

Page 1295: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

21 00 00 Fire Suppression

All items hereunder to be described specified code of practice and regulations, kind, quality,

size, method of fixing , finishes or surface treatments, etc. as per the Drawings nr UB-STP-

21 12 00 Fire Suppression Standpipes

Supply & Installation testing and commissioning of steel pipes (painted). All fire fighting

pipes to be completed including but not limited to accessories, fittings, couplings according

to NFPA code/ local civil defence code. Including all kind of supports and hangers all in

accordance to the specifications and drawings.

1 Fire main pipes, 50mm dia straight, (Type, nominal size, method of jointing, spacing and m

method of fixing supports, etc. as per the Drawings and Specification.

2 Fire main pipes, 40mm dia straight, (Type, nominal size, method of jointing, spacing and m

method of fixing supports, etc. as per the Drawings and Specification.

3 Supply & install NOVEC 1230 nozzle nr

4 Supply & install 22 Kg NOVEC 1230 cylinder nr

5 Supply & install foam chemical sprinkler nr

6 Supply, install, test and commission foam chemical tank 750 x 500 x 1200 (100 litres) set

including proportioning controller, fill cap for the functional and operational installation as

Additional Items

7 The Contractor is to list here and price any items shown on the Drawings, mentioned in the

Specifications or required for the satisfactory completion of this section, but not mentioned

here. Any such items not listed below shall be deemed to be included.

22 00 00 - PLUMBING

All items hereunder to be described specified code of practice and regulations, kind, quality,

size, method of fixing , finishes or surface treatments, etc. as per the Drawings nr UB-STPM201,

202 and Specification).

22 13 16 Sanitary Waste and Vent Piping

Page 1296: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Roof drain system

1 Roof drain pipes 110 mm diameter, straight, (Type, nominal size, method of jointing, spacing m

and method of fixing supports, etc. as per the Drawings and Specification.

Condensate Drain Pipe Works

2 Condensate drain pipes 20 mm diameter, straight, (Type, nominal size, method of jointing, m

spacing and method of fixing supports, etc. as per the Drawings and Specification.

22 40 00 Plumbing Fixtures

All items hereunder to be described with , kind, quality, size, nature of base, method of

fixing, etc. as per the Drawings nr UB-STP-M201,202,P301,302,F201 and Specification).

3 Floor Drain (FD) 75mm nr

4 Area drain, 75mm nr

5 Roof drain (75 dia) nr

6 Oil interceptor nr

7 Soak pit nr

22 00 00 - Plumbing

Additional Items

8 The Contractor is to list here and price any items shown on the Drawings, mentioned in the

Specifications or required for the satisfactory completion of this section, but not mentioned

here. Any such items not listed below shall be deemed to be included.

23 00 00 - HEATING, VENTILATING, AND AIR CONDITIONING (HVAC)

All HVAC works shall be completed as per the Drawings nr UB-STP-M201,M202 and

Specification.

23 07 13 Duct Insulations

All items hereunder to be described with in type, kind, quality, thickness, method of fixing ,

specified codes of practice, etc. as per the Drawings and Specification).

1 Ductwork Insulations including fixing accessories as per the Drawings nr UB-STP-M201, 202 m2

and Specification.

Page 1297: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

23 31 00 HVAC Ducts and Casings

All items hereunder to be described with in type, kind, quality, size, method of fixing ,

specified codes of practice, placing and method of fixing supports, etc. as

2 Fresh air duct per the Drawings m2

23 34 00 HVAC Fans

All items hereunder to be described with information such as appropriate to the

3 Exhaust Fan; 900 L/s, 1.2 Kw, 400/3/60 roof mounted, Up blast nr

4 Exhaust Fan; 170 L/s, 0.2 Kw, 220/1/60 wall mounted nr

5 Exhaust Fan; 225 L/s, 0.25 Kw, 220/1/60 wall mounted Up blast nr

23 37 00 Air outlets and Inlets

All items hereunder to be described with information such as type, kind, quality, size,

method of fixing , specified codes of practice, etc. as per the Drawings and Specification).

6 Supply and install air grille 500mm x 200mm nr

7 Fresh air sand trap louver 1500mm x 300mm nr

HVAC (Cont'd)

Generator radiator exhaust air louver 300mm nr

23 82 00 Convection Heating and Cooling Units

All items hereunder to be described with information such as appropriate to the

procurement , capacity, design, supply, execution, type, kind, quality, size, method of fixing ,

1 Supply and install FCU/ACCU; 335 L/s, 220/1/60 power supply, 309 total load, 3.7 sensible nr

load, Hi-wall deco split

Supply and install Fresh air fan; 900 L/s, 400/3/60 power supply, 1.2 Kw, roof mounted nr

centrifugal fan

23 05 93 Testing, Adjusting and Balancing for HVAC

Page 1298: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

All items hereunder to be described with type of installation, preparatory operations, stages

of test (nr), required attendance, applicable codes etc. as per the Drawings and

Specification).

2 Air balancing of the ducting network Item

3 Testing, balancing and commissioning of all the equipment's Item

Additional Items

4 The Contractor is to list here and price any items shown on the Drawings, mentioned in the

Specifications or required for the satisfactory completion of this section, but not mentioned

here. Any such items not listed below shall be deemed to be included.

26 00 00 - ELECTRICAL

All works hereunder shall be completed as per the Drawings nr STP-IB-EL101-00,201-00,301-

00,302-00601-00,701-00 and Specification.

26 05 19 Low Voltage Electrical Power Conductors and cables

All items hereunder to be described with information such as type, kind, number of cores,

armouring and sheathings, method of fixing , specified codes of practice, etc. as per the

Drawings and Specification).

1 Feeder cables, CU/XLPE/PVC + CU/PVC type, 3 (4C 300 mm2 + 150 mm2 (E)) m

2 Feeder cables, CU/XLPE/PVC + CU/PVC type, 2 (4C 300 mm2 + 150 mm2 (E)) m

3 4C-35mm² + 16mm² E m

4 3C - 185mm² + 95mm² E m

5 3C 16mm² + 16mm² m

6 3C 10mm² + 10mm² m

7 3 X 6mm², CU/XLPE/PVC + CU/PVC m

Page 1299: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

8 Forming and fix hand hole for electricity cabling and routing from the cable trench Item

for operational and functional installation as per drawing and specification

9 Forming and fix cable trench 500mm wide 13 m long for electricity cabling and nr

routing from the cable trench for operational and functional installation as per

ELECTRICAL (Cont'd)

26 05 26 Grounding and Bonding for Electrical Systems

All items hereunder to be described with information such as type, kind, number of cores,

armouring and sheathings, method of fixing , specified codes of practice, etc. as per the

Drawings and Specification).

1 grounding system; 95 mm² bare copper tinned wire nr

2 70 mm² bare copper down conductor nr

3 70 mm² CU/PVC bonding conductor nr

4 Earthling concrete test pit, 350x350mm with cover nr

5 Earthling copper rod, 20mm ø x 3000 nr

6 Bonding of earthing conductor to steel structural columns nr

7 Copper bus bar 610x6x50mm Ea

26 41 13.13 Lightning Protection for Buildings

8 Lightning arrester Ea

9 Lightning down conductor Ea

10 Flat copper conductor m

26 05 33.13 Conduit for Electrical Systems

All items hereunder to be described with information such as type, kind, , method of fixing ,

specified codes of practice, etc. as per the Drawings and Specification).

Page 1300: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

11 Cables and conduits in final circuits, cable installation, size, type and description of final Item

circuit (sockets, switch etc.)

26 24 13 Switchboards

All items hereunder to be described with information such as type, kind, rated capacity,

method of fixing, cores reference to Specification, fuses, background, specified codes of

practice, etc. as per the Drawings and Specification).

ELECTRICAL (Cont'd)

Automatic transfer switch (ATS) nr 1 nr

1 Supply, install, test and commission capacitor bank 150 KVA as per the drawing and nr

specification

26 24 16 Panel boards

All items hereunder to be described with information such as type, kind, rated capacity,

method of fixing, cores reference to Specification, fuses, background, specified codes of

practice, etc. as per the Drawings and Specification).

2 Lighting and power panel (LPP-IB) nr

3 Main Distribution Board (MDB-IB) nr

4 Motor control centre MCC-IB nr

5 Capacitor bank 150KVAR nr

26 27 13 Electricity Metering

6 All items hereunder to be described with information such as type, kind, rated capacity, Item

method of fixing, cores reference to Specification, fuses, background, specified codes of

practice, etc. as per the Drawings and Specification).

26 27 26 Wiring Devices

Switches & Push Buttons

All items hereunder to be described with information such as appropriate to the

procurement , type, kind, quality, size, method of fixing , specified codes of practice, etc. as

per the Drawings and Specification).

Page 1301: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

7 One way one gang switch 15A nr

8 One way two gang switch, 15A nr

9 One way three gang switch, 15A nr

10 Two way one gang switch, 15A nr

Power Outlets

11 Duplex receptacle outlet, 230V, 20A normal power supply nr

ELECTRICAL (Cont'd)

Duplex receptacle outlet, 230V, 20A power supply with water proof cover nr

1 Non-fusible disconnect switch. single pole NEMA 4X nr

2 Non-fusible disconnect switch. three pole NEMA 4X nr

26 28 16.13 Enclosed Circuit Breakers

All items hereunder to be described with information such as type, kind, rated capacity,

method of fixing, cores reference to Specification, fuses, background, specified codes of

practice, etc. as per the Drawings and Specification).

3 Supply, install, test, and commission circuit breaker 100A nr

26 50 00 Lighting

All items hereunder to be described with information such as appropriate to the

procurement , type, kind, quality, size, method of fixing , specified codes of practice, etc. as

per the Drawings and Specification).

4 Luminaire with open end trap around diffuser, 2 No of fluorescent 36W/220V/60Hz lamps, nr

electronic ballast, and clear prismatic pattern (C2 type)

5 Surface mounted industrial fluorescent luminaire with reflector and moulded diffuser cover nr

installed with 2x36W T8 fluorescent lamp for electronic control gears (E1 type)

6 Wall mounted bulkhead outdoor landscape clear with a 100W/220V/60Hz mercury vapour nr

elliptical lamp prismatic pattern moulded polycarbonate diffuser cover of IP-65

Page 1302: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

7 Direct wall mounted single face emergency exit sign, indoor luminaire with a fluorescent nr

8W/220V/60Hz lamp electronic ballast, maintained emergency backup of 3 hours duration &

opal sheet diffuser with sign (exit Arabic & English, up and down in white text & green

background)

26 32 13 Engine Generators

1 Supply, install, test and commission diesel engine generator; 400KVA, 3ph, 400/231V, 60Hz Item

for irrigation water pumping system (kind, size, fitting details, connections, power, head,

accessories, warranty) for operational and functional installation as per the drawing and

equipment schedule and specification

Additional Items

2 The Contractor is to list here and price any items shown on the Drawings, mentioned in the

Specifications or required for the satisfactory completion of this section, but not mentioned

here. Any such items not listed below shall be deemed to be included.

2.1 3C 25mm² + 16mm² CABLE FOR (vertial turbines pumps-1& 4) m

31 00 00 EARTHWORK

All works herein shall be completed in full compliance with the Drawings nr UB-RP-S101,RPS201,

RP-S401 and Specification.

31 10 00 Site Clearing

1 Site preparation, clearing site vegetation m2

31 23 16 Excavation

2 Excavating top soil for preservation, average depth 150mm. m2

3 Excavating pits, depth of excavation not exceeding 2 - 4 m m3

31 23 23.13 Backfill

4 Filling to excavations, average thickness > 0.25 m, arising from excavated materials, all fill m3

shall be compacted to 75% relative density for cohesion-less soils as per ASTM D4254/ASTM

Page 1303: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

D4293 or 95% maximum density as determined by ASTM D698 for cohesive material, as per

the Drawings and Specifications).

31 23 23.23 Compaction

5 Surface treatments, compacting bottom of excavation, compaction to meet 85% of relative m2

density for cohesion-less soils or 95% maximum density as determined by ASTM D1557 for

cohesive materials per the Drawings and Specifications)

31 23 16.26 Rock Removal

6 Disposal of excavated material, off site as stated in the Specification. m3

31 31 16 Termite Control

7 Termite control for the horizontal surface (method and type of treatment as per the m2

Drawings and Specifications)

8 Termite control for vertical surface (method and type of treatment as per the Drawings and m2

Specifications)

EARTHWORK (Cont'd)

Additional Items

1 The Contractor is to list here and price any items shown on the Drawings, mentioned in the

Specifications or required for the satisfactory completion of this section, but not mentioned

here. Any such items not listed below shall be deemed to be included.

32 30 00 SITE IMPROVEMENTS

All works herein shall be completed in full compliance with the Drawings nr RGC-IR-C900,

C901,C902,C903,C904, C910,C911,C915,C916,C922,C923,C930,C931,C932 and Specification.

32 82 00 Irrigation Pumps

Page 1304: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Supply, install, test and commission Vertical turbine pumps (kind, size, fitting details,

connections, power, head, accessories, warranty) for irrigation water pumping system for

operational and functional installation as per the drawing nr RGC_IR_C932 and equipment

schedule and specification

1 VTP pumps, flow rate 68 m³/Hr, 55 m head, 18 Kw ( 2 duty + 2 standby) nr

2 Sump pump; flow rate 20 m³/Hr, 12 m head, 3 Kw ( 1 duty + 1 standby) nr

3 Supply, installation, testing, commissioning, adjusting, balancing, and guarantee including Item

operation, maintenance, tools & spare parts, all mechanical fittings including but not limited

to piping works inside the irrigation pump room, dosing pump, valves, tees, flanges, elbows,

joints, air vent pipes, pressure gauges, pressure switches, flow switches, balancing valves,

flexible connections, rubber isolators, concrete bases, control panel, electrical agitator

connections, fittings, and all necessary to complete the work as per the drawings and

specification and Engineer's instructions

33 00 00 UTILITIES

33 56 00 Fuel-Storage Tanks

As per Q&A no. 365 the word 'fiber glass' to be replace by steel

1 Supply and install steel bulk fuel storage tank 1200ø capacity including all accessories Item

but not limited to piping works for functional and complete operation as per the Drawings

and specification

Additional Items

2 The Contractor is to list here and price any items shown on the Drawings, mentioned in the

Specifications or required for the satisfactory completion of this section, but not mentioned

here. Any such items not listed below shall be deemed to be included.

Total for IRRIGATION WATER STORAGE TANK AND PUMP HOUSE

CARRIED TO SUMMARY

Irriggation System

Irriggation Water Storage Tank and Pump House

Page 1305: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836
Page 1306: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

AMOUNT FOR IRRIGATION SYSTEM, TANK AND PUMP HOUSE TO

SUMMARY

Page 1307: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Qty Rate Amount

11,827 12.00 141,924.00

4,432 27.00 119,664.00

7,324 14.00 102,536.00

4,502 6.00 27,012.00

22 465.00 10,230.00

176 543.00 95,568.00

293 620.00 181,660.00

45 659.00 29,655.00

Page 1308: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

16 1043.00 16,688.00

15 1410.00 21,150.00

1 1962.00 1,962.00

22 114.00 2,508.00

176 187.00 32,912.00

293 272.00 79,696.00

CF 863,165.00

BF 863,165.00

46 81.00 3,726.00

10 55.00 550.00

5 79.00 395.00

5 3689.00 18,445.00

491 66.00 32,406.00

51 45.00 2,295.00

491 218.00 107,038.00

Page 1309: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

13 7.00 91.00

177 7.00 1,239.00

358 7.00 2,506.00

305 7.00 2,135.00

842 7.00 5,894.00

249 7.00 1,743.00

118 7.00 826.00

28 20.00 560.00

37 20.00 740.00

CF 1,043,754.00

BF 1,043,754.00

Page 1310: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2,062 4.00 8,248.00

65 6.00 390.00

4,859 4.00 19,436.00

466,044 2.00 932,088.00

14,425 5.00 72,125.00

1,983 4.00 7,932.00

40,844 6.00 245,064.00

12,846 6.00 77,076.00

23,133 10.00 231,330.00

6,858 12.00 82,296.00

1,981 16.00 31,696.00

1,529 16.00 24,464.00

5,409 26.00 140,634.00

Page 1311: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1,554 50.00 77,700.00

1,973 71.00 140,083.00

60 130.00 7,800.00

1 1590.00 1,590.00

US Dollar. 3,143,706.00

62 188.00 11,656.00

6 449.00 2,694.00

195 426.00 83,070.00

5 744.00 3,720.00

23 557.00 12,811.00

Page 1312: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

7 1004.00 7,028.00

182 755.00 137,410.00

123 511.00 62,853.00

37 677.00 25,049.00

2 543.00 1,086.00

10 738.00 7,380.00

9 1101.00 9,909.00

13 696.00 9,048.00

CF 373,714.00

BF 373,714.00

20 45.00 900.00

590 17.00 10,030.00

Page 1313: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

153 37.00 5,661.00

CF 390,305.00

BF 390,305.00

36 39.00 1,404.00

224 35.00 7,840.00

Page 1314: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 399,549.00

BF 399,549.00

1 1012.00 1,012.00

108 84.00 9,072.00

6 588.00 3,528.00

1 868.00 868.00

1 781.00 781.00

2 452.00 904.00

CF 415,714.00

BF 415,714.00

Page 1315: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

632 36.00 22,752.00

422 31.00 13,082.00

30 5.00 150.00

17 5.00 85.00

930 43.00 39,990.00

1,115 43.00 47,945.00

91 39.00 3,549.00

91 23.00 2,093.00

Page 1316: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 545,360.00

BF 545,360.00

1 2403.00 2,403.00

1 3929.00 3,929.00

2 1254.00 2,508.00

3 326.00 978.00

1 3556.00 3,556.00

Page 1317: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 558,734.00

BF 558,734.00

CF 558,734.00

BF 558,734.00

360 22.00 7,920.00

Page 1318: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

299 29.00 8,671.00

159 44.00 6,996.00

63 19.00 1,197.00

CF 583,518.00

BF 583,518.00

49 11.00 539.00

101 11.00 1,111.00

Page 1319: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

91 44.00 4,004.00

360 11.00 3,960.00

114 12.00 1,368.00

CF 594,500.00

BF 594,500.00

1 116.00 116.00

Page 1320: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 594,616.00

BF 594,616.00

20 0.00 0.00

6 0.00 0.00

1 0.00 0.00

1 0.00 0.00

2 0.00 0.00

1 38306.00 38,306.00

CF 632,922.00

BF 632,922.00

Page 1321: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

20 173.00 3,460.00

15 9.00 135.00

1 193.00 193.00

2 345.00 690.00

3 173.00 519.00

1 19407.00 19,407.00

1 413.00 413.00

CF 657,739.00

BF 657,739.00

20 52.00 1,040.00

Page 1322: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

20 66.00 1,320.00

1 1513.00 1,513.00

1 491.00 491.00

2 615.00 1,230.00

3 64.00 192.00

1 1570.00 1,570.00

CF 665,095.00

BF 665,095.00

1 11800.00 11,800.00

1 1843.00 1,843.00

1 3038.00 3,038.00

Page 1323: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1 207.00 207.00

1 744.00 744.00

CF 682,727.00

BF 682,727.00

20 627.00 12,540.00

15 418.00 6,270.00

15 29.00 435.00

15 113.00 1,695.00

30 15.00 450.00

25 10.00 250.00

30 8.00 240.00

Page 1324: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1 3232.00 3,232.00

2 8056.00 16,112.00

CF 723,951.00

BF 723,951.00

115 17.00 1,955.00

25 13.00 325.00

170 13.00 2,210.00

8 50.00 400.00

4 88.00 352.00

11 70.00 770.00

3 330.00 990.00

12 64.00 768.00

7 77.00 539.00

61 21.00 1,281.00

Page 1325: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1 6246.00 6,246.00

CF 739,787.00

BF 739,787.00

1 33466.00 33,466.00

1 16950.00 16,950.00

1 1342.00 1,342.00

1 16533.00 16,533.00

1 17359.00 17,359.00

1 16950.00 16,950.00

1 0.00 0.00

Page 1326: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2 10.00 20.00

2 12.00 24.00

1 20.00 20.00

2 11.00 22.00

5 19.00 95.00

CF 842,568.00

BF 842,568.00

5 58.00 290.00

2 796.00 1,592.00

5 796.00 3,980.00

1 0.00 0.00

12 128.00 1,536.00

20 128.00 2,560.00

10 410.00 4,100.00

Page 1327: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3 149.00 447.00

CF 857,073.00

BF 857,073.00

1 86371.00 86,371.00

47 21.00 987.00

CF 944,431.00

BF 944,431.00

535 2.00 1,070.00

535 3.00 1,605.00

2,787 8.00 22,296.00

260 12.00 3,120.00

Page 1328: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

535 3.00 1,605.00

2,527 4.00 10,108.00

455 1.00 455.00

525 0.00 0.00

CF 984,690.00

BF 984,690.00

CF 984,690.00

BF 984,690.00

Page 1329: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

4 27917.00 111,668.00

2 6284.00 12,568.00

1 2065.00 2,065.00

CF 1,110,991.00

BF 1,110,991.00

1 17278.00 17,278.00

US Dollar. 1,128,269.00

3,143,706.00

1,128,269.00

Page 1330: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836
Page 1331: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

US Dollar. 4,271,975.00

Page 1332: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Description Unit Qty Rate

ELECTRICAL POWER DISTRIBUTION SYSTEM

MV Power Distribution System

Notwithstanding the provisions of the Standard Method of Measurement, cabling has been

itemized according to size. The Contractor is to make all allowances for the length of cable

required and is to make particular reference to drawing nr MP-EL608. No claim for lack or

want of knowlege will be entertained

1 Medium voltage switchgear Item 1 1194117.00

Package Substation

2 1,000 kVA 3ph 13.8/0.4-0.23KV 60Hz with suitable RMU nr 34 102614.00

3 1,500 kVA 3ph 13.8/0.4-0.23KV 60Hz with suitable RMU nr 4 123259.00

Medium Voltage Power Cable

4 3C x 300 mm² AL/XLPE/TAPE ARMOURED/PVC (COPPER AS PER Q&A 441) m 13,005 209.00

5 3 x 1C x 630 mm² AL/XLPE/TAPE ARMOURED/PVC (COPPER AS PER Q&A 441) m 100 370.00

6 Fiber Optic Cable, 12 mm diameter m 12,773 10.00

Medium Voltage Reinforced Concrete Encased uPVC Ductbank

7 2 x 3x 160 mm m 16 269.00

8 2 x 160 mm m 23 151.00

9 2 x 4 x 160 mm m 35 423.00

10 3 x 160 mm m 298 198.00

11 4 x 160 mm m 13 236.00

Item Nr.

Page 1333: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF

BF

LV Power Distribution System

Notwithstanding the provisions of the Standard method of Measurement, cabling has been

itemized according to size. The Contractor is to make all allowances for the length of cable

required and is to make particular reference to drawing nr MP-EL301 & MP-EL608. No claim

for lack or want of knowledge will be entertained

Low Voltage Cable

1 4C x 300 mm² AL/XLPE/ARMOURED/PVC m 25,792 64.00

2 4C x 70 mm² AL/XLPE/ARMOURED/PVC m 22,445 35.00

3 Low Voltage Distribution Piller nr 326 1625.00

Low Voltage Reinforced Concrete Encased uPVC Ductbank

4 2 x 110 mm m 56 87.00

5 4 x 110 mm m 22 142.00

Page 1334: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

6 6 x 110 mm m 15 193.00

7 2 x 3 x 110 mm m 13 193.00

8 5 x 110 mm m 29 172.00

9 3 x 110 mm m 18 115.00

10 SEC Power Connection and Metering Charges Item 1not in the scope, will be paid by the Client

Additional Items

11 The Contractor is to list here and price any items shown on the Drawings, mentioned in th Item

Specifications or required for the satisfactory completion of this section, but not mentioned

here. Any such items not listed below shall be deemed to be included. item

11.1 M 357 170.00

11.2 M 90 39.00

Total for LOW AND MEDIUM VOLTAGE POWER DISTRIBUTION

CARRIED TO SUMMARY US Dollar.

4CX240mm² CU/PXLPE/PVC+120mm² CU/PVC(E) (Staff Building) (From S/S to MDBs) (As per Q&A # 537)

4CX50MM² CU/SWA/PVC+1x25mm² (From kWH meter to external ltg panel) (As per Q&A # 537)

Page 1335: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Amount

1,194,117.00

3,488,876.00

493,036.00

2,718,045.00

37,000.00

127,730.00

4,304.00

3,473.00

14,805.00

59,004.00

3,068.00

Page 1336: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

8,143,458.00

8,143,458.00

1,650,688.00

785,575.00

529,750.00

4,872.00

3,124.00

Page 1337: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2,895.00

2,509.00

4,988.00

2,070.00

not in the scope, will be paid by the Client

60,690.00

3,510.00

###

Page 1338: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Item Nr. Description Unit Qty

SITE DEVELOPMENT

ELECTRICAL POWER DISTRIBUTION SYSTEM

LV Power Distribution System

Notwithstanding the provisions of the Standard method of Measurement, cabling has been

itemized according to size. The Contractor is to make all allowances for the length of cable

required and is to make particular reference to drawing nrsMP-PS701, 702, 703, 704, 705,

706, 707, 708, 709, 710 No claim for lack or want of knowledge will be entertained

LV Cable

1 4C x 25 mm² Cu/XLPE/SWA/PVC Item 1

2 4C x 10 mm² Cu/XLPE/SWA/PVC Item 1

Grounding Cable

3 1C x 16 mm² Cu/PVC Item 1

STREET LIGHTING SYSTEM

Supply and Install street lighting poles and fittings; including lamp; Allow for all cables and

conduits, including trenching and backfilling as per Engineer's Instruction

4 Street Lighting Panels (SLP) Ea 9

5 Lighting pole; 10 m height with one arm; 150W MH. Lamp Ea 280

6 Lighting pole; 10 m height with two arms; 150W MH. Lamp Ea 22

Low Voltage Reinforced Concrete Encased uPVC Duct bank

7 2 x 110 mm dia. m 153

Supply and Install landscape lighting poles and fittings; including lamp; Allow for all cables

and conduits, including trenching and backfilling as per Engineer's Instruction

8 Bollard compact fluorescent lighting luminaire with electronic power supply; 26W, 230V, 6 Ea 1,036

Hz

9 Bollard compact fluorescent lighting luminaire with electronic power supply; 21W, 230V, 6 Ea 1,606

Hz

10 Floodlight, lighting luminaire in 1000W, 230V metal halide lamp Ea 33

Page 1339: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

11 Floodlight, lighting luminaire in 2000W, 230V metal halide lamp Ea 19

Ea.

12 Landscape upright luminaire 1x35W, 220V, 90Hz Ea 248

13 LED compact recessed under water projector lighting 1x12W, 230V, 60Hz Ea 128

14 LED C-Splash2 tri-colour under water lamp 1x18W, 230V, 24V, 60Hz Ea 34

15 Panel board with lighting control Ea 30

ADDITIONAL (AS PER Q&A # 496)

16 Lighting poles with double arms, 12 meters height. Ea 40

17 Lighting poles with single arms, 12 meters height. Ea 111

Total for STREET LIGHTING

CARRIED TO SUMMARY

Removal and deportation of the existing Lighting Poles of the project site to the location specified by the Owner within the City of Rityadh:

Page 1340: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Rate Amount

396143.00 396,143.00

649336.00 649,336.00

34461.00 34,461.00

3070.00 27,630.00

1904.00 533,120.00

2646.00 58,212.00

162.00 24,786.00

952.00 986,272.00

842.00 1,352,252.00

1808.00 59,664.00

Page 1341: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2401.00 45,619.00

822.00 203,856.00

2850.00 364,800.00

3984.00 135,456.00

3070.00 92,100.00

104.00 4,160.00

104.00 11,544.00

US Dollar. 4,979,411.00

Page 1342: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Item Nr. Description Unit Qty Amount

04 00 00 MASONRY

04 20 00 Unit Masonry

Notwithstanding the Provisions of the Standard Method of

Measurement of Building Works Seventh Edition, 1988 (SMM7) the

following unit masonry walls & fences are measured in "m" and

referenced to wall type as stated in the Drawings. The contractor is

to make due reference to Drawings for full details and allow for all

associated works including but not limited to excavation,

foundation, finishes etc. required to complete the works in

accordance with the Drawings and Specification. No claim for want

or lack of knowledge will be entertained

LS-HP124 and Specifications.

1 Supply and construct screen wall between apartment buildings, , m 564 498.00 280,872.00

type W-1, 200 mm width x 1,500 mm height CMU, rendered finish,

as per the Drawings and Specification

2 m 63 565.00 35,595.00

height wall, rendered finish, Pot pedestal 600mm height x 300mm

thick rendered finish with Granite cap, as per the Drawings and

Specification

3 Supply and construct playground wall with writing wall and learning m 18 853.00 15,354.00

tiles, type W-3, 200 mm thick x 1600 mm height, including 12mm

thick chalk writing surface attached to CMU writing wall, smooth

finish, 500mmx500mmx40mm thick sandstone learning tiles, CMU

Screen wall 1800mm height 400mm, rendered finish with granite

cap, CMU Seat wall 400mm height 400 thick, rendered finish with

All works hereunder to be completed as per the Drawings nr LSHP002,

LS-HP100, LS-HP101, LS-HP102, LS-HP103, LS-HP104, LSHP105,

LS-HP106, LS-HP107, LS-HP108, LS-HP109, LS-HP110, LSHP111,

LS-HP112, LS-HP113, LS-HP114, LS-HP115, LS-HP116, LSHP117,

LS-HP118, LS-HP119, LS-HP120, LS-HP121, LS-HP122, LSHP123,

Supply and construct pool wall, type W-2, including 400m - 1800mm

Page 1343: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

granite cap, as per the Drawings and Specification

4 m 42 573.00 24,066.00

x 400 mm height, rendered finish with granite cap, as per the

Drawings and Specification

5 Supply and construct CMU seat wall, type W-5, 400 mm thick x 450 m 9 576.00 5,184.00

Specification

CF 361,071.00BF 361,071.00

Masonry Cont'd

1 m 34 811.00 27,574.00

mm thick x 900 mm height screen wall, rendered finish , 300mm

thick x 1,000 mm height pot pedestal, rendered finish with granite

cap, as per the Drawings and Specification

2 Supply and construct CMU retaining wall, type W-7, 300 mm thick x m 62 599.00 37,138.00

700-2,000 mm height, rendered finish, as per the Drawings and

Specification

3 Supply and construct CMU screen wall, type W-8, 300 mm thick x m 10 589.00 5,890.00

Supply and construct CMU planter seat wall, type W-4, 400 mm thick

mm height, rendered finish with granite cap, as per the Drawings and

Supply and construct CMU playground wall, type W-6, including 400

Page 1344: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

700-2,000 mm height, rendered finish, as per the Drawings and

Specification

4 Supply and construct CMU retaining wall, type W-9, 300 mm thick x m 23 589.00 13,547.00

1500mm height, rendered finish, as per the Drawings and

Specification

5 Supply and construct CMU planter seat wall, type W-10, 300 mm m 161 516.00 83,076.00

thick x 450 mm height, rendered finish with granite cap, as per the

Drawings and Specification

6 Supply and construct CMU pool screen/planter wall, type W-11, m 13 568.00 7,384.00

including 200 mm thick x 1,800 mm height screen wall rendered

finish, 200 mm thick x 450 mm height planter wall rendered finish,

500 mm thick x 450 mm height planter seat wall, rendered finish

with granite cap, as per the Drawings and Specification

7 Supply and construct CMU planter seat wall, type W-12, 300 mm m 289 526.00 152,014.00

thick x 450 mm height, rendered finish with granite cap, as per the

Drawings and Specification

8 Supply and construct CMU planter wall, type W- 13, 200 mm thick x m 29 404.00 11,716.00

300 mm height, rendered finish, as per the Drawings and

Specification

9 Supply and construct CMU planter wall, type W- 14, 200 mm thick x m 150 401.00 60,150.00

800 mm height, rendered finish, as per the Drawings and

Specification

10 m 35 878.00 30,730.00

finish including 800mm x 1400mm x 100mm thick window sills with

granite, as per the Drawings and Specification

Supply and construct screen wall with windows, type W-15, rendered

Page 1345: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 790,290.00BF 790,290.00

Masonry Cont'd

1 Supply and construct tapered screen wall, type W-16, 600mm - m 15 408.00 6,120.00

1500mm height, rendered finish as per the Drawings and

Specification

2 m 30 525.00 15,750.00

height, rendered finish, as per the Drawings and Specification

3 Supply and construct CMU planter seat wall, type W-18, 300 mm m 10 524.00 5,240.00

thick x 450 mm height, rendered finish with granite cap, as per the

Drawings and Specification

4 Supply and construct CMU planter seat wall, type W-19, 300 mm m 15 523.00 7,845.00

thick x 450 mm height, rendered finish with granite cap, as per the

Drawings and Specification

5 m 10 676.00 6,760.00

600mm thick low wall, rendered finish, 2000mm height x500mm

500mm tall columns rendered finish, as per the Drawings and

Specification

6 Supply and construct CMU planter seat wall, type W-21, 400 mm m 24 559.00 13,416.00

thick x 400 mm height, rendered finish with granite cap, as per the

Drawings and Specification

7 Supply and construct CMU planter wall, type W- 22, 300 mm thick x m 76 396.00 30,096.00

500 mm height, rendered finish, as per the Drawings and

Specification

8 Supply and construct pool wall, type W-23, including wall height m 40 621.00 24,840.00

Supply and construct screen wall, type W-17, 200mm thick 1800mm

Supply and construct screen wall, typeW-20, including 800mm height

400m - 1800m, rendered finish, Pot pedestal 600mm height, 300mm

Page 1346: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

thick with Granite cap, as per the Drawings and Specification

9 Supply and construct pool screen wall, type W-24, 200 mm thick x m 10 514.00 5,140.00

1700 mm height, rendered finish, as per the Drawings and

Specification

10 m 15 494.00 7,410.00

height, rendered finish, as per the Drawings and Specification

CF 912,907.00BF 912,907.00

Masonry Cont'd

1 Supply and construct pool wall, type W-26, 200 mm thick x 600 mm m 45 386.00 17,370.00

height, rendered finish, as per the Drawings and Specification

2 Supply and construct CMU planter seat wall, type W-27, 300 mm m 16 502.00 8,032.00

thick x 450 mm height, rendered finish with granite cap, as per the

Drawings and Specification

3 m 23 513.00 11,799.00

type W-28, including 300mm thick 300mm - 800mm height variable

propane tank (400mm diameterx500mm high tank) storage cabinet

Supply and construct pool wall, type W-25, 200 mm thick x 1500 mm

Supply and construct variable height wall with propane tank storage,

wall, rendered finish, 1000mm wide x 1200mm deep x 1000mm High

Page 1347: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

with lockable ventilated steel access door, , rendered finish with

granite cap, as per the Drawings and Specification

4 Supply and construct CMU planter seat wall, type W-29, 400 mm m 15 556.00 8,340.00

thick x 450 mm height, rendered finish with granite cap, as per the

Drawings and Specification

5 Supply and construct tapered retaining screen wall, type W-30, m 65 663.00 43,095.00

rendered finish, as per the Drawings and Specification

6 Supply and construct CMU planter / seat wall, type W-31, 300 mm m 98 502.00 49,196.00

thick x 450 mm height, rendered finish with granite cap, as per the

Drawings and Specification

7 Supply and construct entry courtyard wall, type W-32, including m 59 613.00 36,167.00

screen wall with windows, 400mm thick x 1800 height, rendered

finish, screen wall, 200mm thick 2200mm height, rendered finish,

seat wall 400mm thick x 400mm height, rendered finish with granite

cap, planter seat wall, 300mm thick x 450mm height rendered finish

with granite cap, as per the Drawings and Specification

8 m 136 499.00 67,864.00

450mm height CMU wall, rendered finish with 80mm thick wood

cap, as per the Drawings and Specification

9 Supply and construct screen wall between staff building and water m 40 600.00 24,000.00

finish, as per the Drawings and Specification

CF 1,178,770.00BF 1,178,770.00

Masonry Cont'd

1 Supply and construct screen wall in front of staff building, type W- m 74 525.00 38,850.00

the Drawings and Specification

Supply and construct garden planter wall, type W-33, 200mm thick x

tank, type W-34, 300mm thick x 2100mm height CMU wall, rendered

35, 200mm thick x 1800mm height CMU wall, rendered finish, as per

Page 1348: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2 Supply and construct screen wall in front of maintenance, water m 30 525.00 15,750.00

height CMU wall, rendered finish, as per the Drawings and

Specification

3 Supply and construct seat wall in front of staff building, type W-37, m 39 915.00 35,685.00

cap, including tubular steel fence with 50mm sq. posts equally

spaced at 1500mm o.c. maximum, 50mmx35mm top and bottom

rails and 30mmx100mm vertical pickets at 130mm o.c.,1300mm

height, as per the Drawings and Specification

4 Supply and construct seat wall in front of staff building, type W-38, m 75 683.00 51,225.00

cap, including tubular steel fence with 50mm sq. posts equally

spaced at 1500mm o.c. maximum, 50mmx35mm top and bottom

rails and 30mmx100mm vertical pickets at 130mm o.c.,1300mm

height, as per the Drawings and Specification

5 m 80 523.00 41,840.00

200mm thick x 1800mm height CMU wall, as per the Drawings and

Specification

6 Supply and construct planter wall at main pool , type W-40, 250mm m 175 478.00 83,650.00

thick x 200mm - 400mm height, rendered finish with granite cap

(white colour with tam/brown specks), as per the Drawings and

Specification

7 Supply and construct Planter wall at Banquet Room Courtyard, type m 24 393.00 9,432.00

W-41, 250mm thick x 300mm height CMU wall, rendered finish, as

per the Drawings and Specification

8 Supply and construct Planter/seat wall at Banquet Room Courtyard, m 47 737.00 34,639.00

type W-42, 550mm thick x 450mm - 400mm height, rendered finish

with granite cap (white colour with tam/brown specks), as per the

Drawings and Specification

storage tanks and STP building, type W-36, 200mm thick x 1800mm

600mm thick x 450mm height CMU wall, rendered finish with granite

400mm thick x 450mm height CMU wall, rendered finish with granite

Supply and construct screen wall at serviced apartments, type W-39,

Page 1349: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 1,489,841.00BF 1,489,841.00

Masonry Cont'd

1 Supply and construct decorative panel fence outside of indoor pool, m 40 1450.00 58,000.00

type W-43, including Perforated metal panels

CMU planter wall 250mm thick x 450mm height . rendered finish

with granite cap (white colour with tam/brown specks), as per the

Drawings and Specification

2 Supply and construct screen wall at screen wall in front of showers, m 10 620.00 6,200.00

type W-44, 250mm thick x 2400mm height CMU wall, rendered

finish, as per the Drawings and Specification

3 Supply and construct at Screen wall at loading dock m 55 620.00 34,100.00

, type W-45, 250mm thick x 2200mm height CMU wall, rendered

finish, as per the Drawings and Specification

4 m 28 720.00 20,160.00

the Drawings and Specification

5 Supply and construct Screen wall behind showers, type W-47, m 29 783.00 22,707.00

250mm thick x 2200mm height CMU wall, rendered finish/ tiles for

SF-14, as per the Drawings and Specification

6 Supply and construct Pool equipment wall at loading dock, type W- m 25 559.00 13,975.00

thick 180mm height metal door with lockable latch, as per the

Drawings and Specification

7 Supply and construct Planter/retaining wall at main pool, type W-49, m 13 504.00 6,552.00

250mm thick x 200mm-400mm height CMU wall, rendered finish

with granite cap (white colour with tam/brown specks), as per the

Drawings and Specification.

7mm thick with variable heights, metal posts 80mm x 80mm x 7mm,

Supply and construct Radiused screen wall at loading dock, type W-

46, 350mm thick x 2400mm height CMU wall, rendered finish, as per

48, 250mm thick x 2000mm height CMU wall, rendered finish,38mm

Page 1350: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

8 Supply and construct Planter/retaining wall at main pool, type W-50, m 8 524.00 4,192.00

250/350mm thick x 200mm-400mm height CMU wall, rendered

finish with granite cap (white colour with tam/brown specks), as per

the Drawings and Specification.

9 Supply and construct Planter/retaining wall at main pool, type W-51, m 23 583.00 13,409.00

250/350mm thick x 1000mm height CMU wall, rendered finish with

granite cap (white colour with tam/brown specks), as per the

Drawings and Specification.

CF 1,669,136.00BF 1,669,136.00

Masonry Cont'd

1 Supply and construct Planter/seat wall at Tropical Island Pool, type m 14 668.00 9,352.00

W-52, 450mm thick x 300mm height CMU wall, rendered finish with

granite cap (white colour with tam/brown specks), as per the

Drawings and Specification.

2 m 14 760.00 10,640.00

53, 550mm thick x 450mm height CMU wall, rendered finish with

granite cap (white colour with tam/brown specks), as per the

Drawings and Specification.

3 m 30 756.00 22,680.00

54, 550mm thick x 450mm height CMU wall, rendered finish with

granite cap (white colour with tam/brown specks), as per the

Drawings and Specification.

4 m 15 492.00 7,380.00

55, 350mm thick x 600mm height CMU wall, rendered finish, as per

the Drawings and Specification.

5 Supply and construct Planter/seat wall at Tropical Island pool, type m 53 704.00 37,312.00

W-56, 600mm thick x 350mm height CMU wall, rendered finish with

granite cap (white colour with tam/brown specks), as per the

Drawings and Specification.

Supply and construct Planter/seat wall at Triangular pergola, type W-

Supply and construct Planter/seat wall at Triangular pergola, type W-

Supply and construct Planter/seat wall at Triangular pergola, type W-

Page 1351: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

6 Supply and construct Tree screen wall, type W-57, 350mm thick x m 17 624.00 10,608.00

1800mm height CMU wall, rendered finish, as per the Drawings and

Specification.

7 Supply and construct Seat /screen wall, type W-58, 450mm thick x m 80 636.00 50,880.00

450mm height CMU seat wall, rendered finish, 350mm thick x

1500mm height CMU screen wall, rendered finishes per the

Drawings and Specification.

8 Supply and construct Screen wall between seating area and loading m 30 519.00 15,570.00

dock in front of staff building, type W-36, 1700mm height, 200mm

thick CMU wall as per the Drawings and Specification.

9 Supply and construct Heavy gauge galvanized chain link fence with m 39 120.00 4,680.00

75mm dia. posts at max. 2400mm o.c., 50mm dia, top and bottom

rails. Type W-37, as per the Drawings and Specification

CF 1,838,238.00BF 1,838,238.00

Masonry Cont'd

1 Supply and construct metal screen fence with steel tube posts and m 75 1060.00 79,500.00

metal panels, type W-38, 2840mm height, including steel tubing

posts, horizontal rails and vertical rails, natural light sandstone,

natural dark sandstone, granite, steel panels/sheets as per the

Drawings and Specification

2 Supply and construct Screen wall with large pot, type W-46, m 28 555.00 15,540.00

including Wall tapers from 500mm-2400mm height, 250mm thick,

rendered finish, pot pedestal, 700mm height, CMU wall, as per the

Drawings and Specification

3 Supply and construct low wall with built in pot, type W-47, 900mm m 29 661.00 19,169.00

CMU wall height , 300mm thick, concrete Pot set into wall 250mm,

as per the Drawings and Specification.

4 Supply and construct Planter/seat wall, type W-48, 400mm height x m 25 474.00 11,850.00

Page 1352: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

350mm thick CMU wall, as per the Drawings and Specification.

5 Supply and construct screen wall at play area, type W-49, 1600mm m 13 601.00 7,813.00

height x 250mm thick CMU wall, as per the Drawings and

Specification.

6 Supply and construct high screen wall at play area, type W-50, m 8 596.00 4,768.00

1800mm height x 250mm thick CMU wall, as per the Drawings and

Specification.

7 Supply and construct planter/seat wall at Tropical Island Pool, type m 23 507.00 11,661.00

and Specification.

Total for Masonry

CARRIED TO SUMMARY US Dollar 1,988,539.00

11 00 00 EQUIPMENT

11 68 16 Play Structures

Following Play Structures to be supplied and installed by the

contractor as per the selections and requirements of the

management company in accordance with the Drawings and

Specification. The contractor is to make due reference to Drawings

for full details and is to allow cost for necessary works required to

complete the installation in accordance with the Drawings,

Specification and satisfaction of the management company . No

claim for want or lack of knowledge will be entertained.

W-51, 300mm height x 350mm thick CMU wall, as per the Drawings

All play structures hereunder to be read with the Drawings nr LSHP002,

LS-HP100, LS-HP101, LS-HP102, LS-HP103, LS-HP104, LSHP105,

LS-HP106, LS-HP107, LS-HP108, LS-HP109, LS-HP110, LSHP111,

LS-HP112, LS-HP113, LS-HP114, LS-HP115, LS-HP116, LSHP117,

LS-HP118, LS-HP119, LS-HP120, LS-HP121, LS-HP122, LSHP123,

LS-HP124, LS-HP201, LS-HP202, LS-HP203, LS-HP204, LSHP205,

LS-HP206, LS-HP207, LS-HP208, LS-HP209, LS-HP210, LSHP211,

Page 1353: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

LS-HP218, LS-HP219, LS-HP220, LS-HP221, LS-HP222,

pipe with wood Yellow pipe with wood Red pipe with wood to be

chosen by management company.

1 Type FT-1, Pipeline fitness route - Instructions Sign - 9700S, nr 1 3970.00 3,970.00

2 Type FT-2, Pipeline fitness route -Heel - Flex - 9701 nr 1 3363.00 3,363.00

3 Type FT-3, Pipeline fitness route - Toe - Reach - 9702 nr 1 14932.00 14,932.00

4 Type FT-4, Pipeline fitness route - Toe - Touch - 9703 nr 1 3970.00 3,970.00

5 Type FT-5, Pipeline fitness route - Knee - Grip - 9704 nr 2 3973.00 7,946.00

6 Type FT-6, Pipeline fitness route - Straddle - Jump - 9705 nr 1 3473.00 3,473.00

7 Type FT-7, Pipeline fitness route - Hop -Over - 9706 nr 1 2964.00 2,964.00

8 Type FT-8, Pipeline fitness route - Leg - Flex - 9707 nr 1 4218.00 4,218.00

9 Type FT-9, Pipeline fitness route - Arm - Stretch - 9708 nr 1 9521.00 9,521.00

CF 54,357.00BF 54,357.00

Equipment Cont'd

1 Type FT-10, Pipeline fitness route - Body - Tuck - 9709 nr 1 15030.00 15,030.00

2 Type FT-11, Pipeline fitness route - Body - Pull - 9710 nr 1 3744.00 3,744.00

3 nr 1 9719.00 9,719.00

4 Type FT-13, Pipeline fitness route - Leg - Kick - 9711 nr 1 3508.00 3,508.00

5 Type FT-14, Pipeline fitness route - Vault - Over - 9712 nr 1 3017.00 3,017.00

6 Type FT-15, Pipeline fitness route - Sit - Up - 9713 nr 1 8071.00 8,071.00

7 Type FT-16, Pipeline fitness route - Push - Off - 9714 nr 1 3660.00 3,660.00

8 Type FT-17, Pipeline fitness route - Leg - Over - 9715 nr 1 4849.00 4,849.00

LS-HP212, LS-HP213, LS-HP214, LS-HP215, LS-HP216, LSHP217,

For all pipeline fitness Route colors to be :Green pipe with wood Blue

Type FT-12, Military Fitness - P-14048-10 foot Rope Climb - Two Boys

Page 1354: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

9 Type FT-18, Pipeline fitness route - Arm - Walk - 9716 nr 1 3687.00 3,687.00

10 Type FT-19, Pipeline fitness route - Hip -Flex - 9717 nr 1 3291.00 3,291.00

11 Type FT-20, Pipeline fitness route - Beam - Walk - 9718 nr 1 4307.00 4,307.00

12 Type FT-21, Military Fitness - P-14048-Chin - up Apparatus - Four nr 1 4244.00 4,244.00

Boys

For all Health beat for Age 13 plus colour to be Demin + Silver

13 Type FT-22, Health beat - Welcome intro sign ages 13+, 161437 nr 1 2764.00 2,764.00

14 Type FT-23, Health beat - Chest and back press ages 13+, 161309 nr 1 6755.00 6,755.00

15 Type FT-24, Health beat - Plyometrics ages 13+, 161317 nr 1 4342.00 4,342.00

16 Type FT-25, Health beat - Squat press, ages 13+, 161310 nr 1 7043.00 7,043.00

17 nr 1 7017.00 7,017.00

CF 149,405.00BF 149,405.00

Equipment Cont'd

1 Type FT-27, Health beat - Pull up and dip, ages 13+, 161313 nr 1 7005.00 7,005.00

2 Type FT-28, Health beat - Cardio stepper, ages 13+, 161313 nr 1 7970.00 7,970.00

3 Type PS-1, Weevos ages 2-5 - 3067 nr 1 41129.00 41,129.00

4 Type PS-2, Evos for ages 5-12 - 1904 nr 1 49859.00 49,859.00

5 Type PS-3, Rhino - Dino for ages 2-12 – 1068 nr 1 2473.00 2,473.00

6 Type PS-4, Play Shaper ages 6-23 months - 3577 nr 1 17050.00 17,050.00

Type FT-26, Health beat - Abs crunch and leg lift, ages 13+, 161314

Page 1355: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

7 Type PS-5, Toddler picnic table for ages 2-5 – 3278 nr 1 1153.00 1,153.00

8 Type PS-6, 3-Panel Mobius Climber nr 1 9227.00 9,227.00

9 Type PS-7, Weevos for ages 2-5 - 3013 nr 1 87879.00 87,879.00

10 Type PS-8, Tuffriders 2 seat Airplane for ages 2-12 – 1056 nr 1 1814.00 1,814.00

11 Type PS-9, Tuffriders fire horse for ages 2-12 – 1064 nr 1 2270.00 2,270.00

12 Type PS-10, Play Shaper ages 6-23 months - 3793-Modified nr 1 31443.00 31,443.00

13 Type PS-11, Sensory play center ages 2-5 –2711 nr 1 15419.00 15,419.00

14 Type PS-12, Double post swing for ages 2-12 – 3408 nr 1 5114.00 5,114.00

15 Type PS-13, Zipkrooz 66 for ages 5-12 - 3878 nr 1 12772.00 12,772.00

16 Type PS-14, Adventurescapes for ages 5-12 - 2699 nr 1 17506.00 17,506.00

17 Type PS-15, Playbooster ages 5-12 - 3881 nr 1 107369.00 107,369.00

18 Type PS-16, Tuffriders fire Engine for ages 2-12 – 126378 nr 1 1792.00 1,792.00

19 Type PS-17, Weevos ages 5-12 - 3799 nr 1 67838.00 67,838.00

CF 636,487.00BF 636,487.00

Equipment Cont'd

1 Type PS-18, Evos for ages 5-12 - 3731 nr 1 56286.00 56,286.00

2 Type PS-19, Omnispin spinner for ages 5-12 – 3039 nr 1 11091.00 11,091.00

3 Type PS-20, Eclipse Net Climber ages 5-12 - 3028 nr 1 24833.00 24,833.00

4 Type PS-21, Smart play motion playhouse ages 2-5 - 3882 nr 2 34983.00 69,966.00

5 nr 2 40936.00 81,872.00

6 Type PS-23, Columbia Cascade timberform for ages 2-5 – 4803-TF nr 2 35766.00 71,532.00

7 nr 1 84050.00 84,050.00

Type PS-22, Columbia Cascade timberform for ages 5-12 – 4816-TF

Type PS-24, Columbia Cascade timberform for ages 5-12 – 4846-TF

Page 1356: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

8 Type PS-25, Columbia Cascade timberform for ages 2-5 – 4801-TF nr 1 29349.00 29,349.00

9 Type PS-26, Sensory play center for ages 2-5 –2709 nr 1 19950.00 19,950.00

10 nr 1 96449.00 96,449.00

11 Type PS-28, Weevos ages 2-5 - 3801 nr 1 53167.00 53,167.00

12 Type PS-29, Evos for ages 5-12 - 3761 nr 1 71591.00 71,591.00

13 Type PS-30, Adventurescapes for ages 5-12 - 2690 nr 1 59607.00 59,607.00

14 Type PS-31, Playshaper for ages 2-5 – 2180 nr 1 31494.00 31,494.00

15 Type PS-32, Play Shaper ages 6-23 months - 3577 nr 1 17050.00 17,050.00

Total for Equipment

CARRIED TO SUMMARY US Dollar 1,414,774.00

12 00 00 FURNISHINGS

12 50 00 Furniture

Following Furnitures hereunder to be supplied and installed by the

contractor as per the selections and requirements of the

management company in accordance with the Drawings and

Specification. The contractor is to make due reference to Drawings

for full details and is to allow cost for necessary works required to

complete the installation in accordance with the Drawings,

Specification and satisfaction of the management company . No

claim for want or lack of knowledge will be entertained.

Type PS-27, Columbia Cascade timberform for ages 5-12 – 4820-TF

All items hereunder to be read with the Drawings nr LS-HP002, LSHP100,

LS-HP101, LS-HP102, LS-HP103, LS-HP104, LS-HP105, LSHP106,

LS-HP107, LS-HP108, LS-HP109, LS-HP110, LS-HP111, LSHP112,

LS-HP113, LS-HP114, LS-HP115, LS-HP116, LS-HP117, LSHP118,

LS-HP119, LS-HP120, LS-HP121, LS-HP122, LS-HP123, LSHP124,

LS-HP201, LS-HP202, LS-HP203, LS-HP204, LS-HP205, LSHP206,

Page 1357: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

LS-HP219, LS-HP220, LS-HP221, LS-HP222,

1 nr 206 186.00 38,316.00

2 Poolside table with umbrella and chairs, type FU-2, as per the nr 85 570.00 48,450.00

Drawings and Specification

3 Bench, type FU-3, as per the Drawings and Specification nr 101 136.00 13,736.00

4 Trash receptacle, FU-4, as per the Drawings and Specification Item 1 2684.00 2,684.00

5 Covered seating area, type FU-5, including metal framed pergola Item 1 0.00

6 Type FU-6, indicated space for wheelchair, no painting or extra nr 11 207.00 2,277.00

materials required, as per the Drawings and Specification

7 Table with umbrella and chairs, type FU-7, as per the Drawings and nr 18 570.00 10,260.00

Specification

CF 115,723.00BF 115,723.00

FURNISHINGS Cont'd

12 93 00 Site Features & Furnishings

Following Site Features & Furnishings items to be supplied and

installed by the contractor as per the selections and requirements of

the management company in accordance with the Drawings and

Specification. The contractor is to make due reference to Drawings

for full details and is to allow cost for necessary works required to

complete the installation in accordance with the Drawings,

Specification and satisfaction of the management company . No

claim for want or lack of knowledge will be entertained.

LS-HP207, LS-HP208, LS-HP209, LS-HP210, LS-HP211, LSHP212,

LS-HP213, LS-HP214, LS-HP215, LS-HP216, LS-HP217, LSHP218,

Pool chaise lounge, type FU-1, as per the Drawings and Specification

with geotextile frabric covering as per the Drawings and Specification

All items hereunder to be read with the Drawings nr LS-HP002, LSHP100,

Page 1358: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

LS-HP219, LS-HP220, LS-HP221, LS-HP222,

8 nr 91 380.00 34,580.00

and Specification

9 Pot on pedestal, type SF-2 as per the Drawings and Specification nr 11 1487.00 16,357.00

10 Sculpture / fire ring area, type SF-3, including but not limited to nr 1 38936.00 38,936.00

(1) 1000mmx1000mmx2500mm tall rounded and (1)

2600mmx1200mmx1000mm tall rounded. (Height indicated is the

minimum above grade dimension), 1000m diameter stainless steel

fire ring with remote propane gas tank, key operated automatic

ignition and automatic timer shut-off, 50mm thick layer of heat

wide seat wall, 1400mmx900mmx1000mm High propane tank

(400mm diameterx500mm high tank) storage cabinet with lockable

per the Drawings and Specification

11 nr 6 8259.00 49,554.00

as per the Drawings and Specification

CF 255,150.00BF 255,150.00

FURNISHINGS Cont'd

1 nr 2 1487.00 2,974.00

Specification

LS-HP101, LS-HP102, LS-HP103, LS-HP104, LS-HP105, LSHP106,

LS-HP107, LS-HP108, LS-HP109, LS-HP110, LS-HP111, LSHP112,

LS-HP113, LS-HP114, LS-HP115, LS-HP116, LS-HP117, LSHP118,

LS-HP119, LS-HP120, LS-HP121, LS-HP122, LS-HP123, LSHP124,

LS-HP201, LS-HP202, LS-HP203, LS-HP204, LS-HP205, LSHP206,

LS-HP207, LS-HP208, LS-HP209, LS-HP210, LS-HP211, LSHP212,

LS-HP213, LS-HP214, LS-HP215, LS-HP216, LS-HP217, LSHP218,

Tree grate, type SF-1, 1000mm x 1000mm size, as per the Drawings

natural stone boulders. (1) 2400mmx2400mmx3200mm tall angular,

resistant gravel / glass nuggets over fire rings, 400mm Highx500mm

ventilated steel access door, pot on propane tank storage cabinet, as

Large outdoor chess set (Plastic), type SF-5, size 2400mm x 2400mm

Pre-cast concrete pot on pedestal, type SF-7, as per the Drawings and

Page 1359: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2 Fire ring/seating area, type SF-8, including but not limited to natural nr 2 6094.00 12,188.00

stone boulders. (3) boulders ranging from 300mmx300mmx200mm

high to 500mmx300mmx600mm high. (Height indicated is the

minimum above grade dimension). minimum 1/3 of boulder to be

buried, 1000mm diameter stainless steel fire ring with remote

propane gas tank, key operated automatic ignition and automatic

timer shut-off, 50mm thick layer of heat resistant gravel/glass

nuggets over fire rings, 400mm highx300mm wide seat wall, as per

the Drawings and Specification.

3 nr 2 1487.00 2,974.00

Specification

4 Pre-cast concrete children's play table, type SF-10 as per the nr 5 682.00 3,410.00

Drawings and Specification

5 Approximately 1000mm diameter x 2000mm tall modern sculpture nr 1 24775.00 24,775.00

per the Drawings and Specification

6 Approximately 1000mmx1000mmx3000m tall natural stone leasing nr 1 37162.00 37,162.00

office sign column with metal or stone, type SF-12, as per the

Drawings and Specification.

7 Concrete steps, type SF-13, as per the Drawings and Specification. nr 3 5132.00 15,396.00

8 Outdoor shower area, type SF-14, including but not limited to nr 1 9868.00 9,868.00

outdoor rated shower unit with shower head and controls, shower

floor tile with slip resistant ceramic tile, shower wall tile

with smooth ceramic tile, 400mm highx590mm wide seat wall with

flamed granite seat, smooth ceramic tile face, as per the Drawings

and Specification

CF 363,897.00BF 363,897.00

FURNISHINGS Cont'd

Pre-cast concrete pot on pedestal, type SF-9 as per the Drawings and

centered on doorway across pool with metal or stone, type SF-11, as

Page 1360: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1 nr 1 10323.00 10,323.00

15, including but not limited to 60mm square metal frame, 3mm

thick Decorative metal grill work as per the Drawings and

Specification.

2 nr 1 1900.00 1,900.00

Drawings and Specification.

3 Tubular steel "A" shaped vine trellis sitting on planter wall, type SF- nr 2 19920.00 39,840.00

17, including but not limited to tubular steel "A" shaped vine trellis,

CMU Vine trellis base, 400mm highx300mm wide CMU planter/seat

wall as per the Drawings and Specification.

4 Three tiered planter/sculpture, type SF-18, including but not limited nr 1 3799.00 3,799.00

to 1500mm diameter pre-cast concrete bowl set on gravel, 1000mm

5 Family sculpture, type SF-19, including but not limited to Item 1 5253.00 5,253.00

100mmx200mm x 5mm thick steel tubing, 5mm Thick steel plate,

600mmx500mmx400mm steel Base plate, as per the Drawings and

Specification.

6 Bus stop, type BS-1, including but not limited to overhead structure nr 48 14178.00 680,544.00

with metal, bench, precast concrete trash receptacle as per the

Drawings and Specification.

7 nr 6 57754.00 346,524.00

door for propane tank and automatic timer shut-off, stainless steel

professional-grade gas grill that also cooks with charcoal and wood.

cast brass dragon burners with a cooking heat at 25,000 btus each,

1000mm widex1200mm deepx1000mm High propane tank (400mm

steel access door, as per the Drawings and Specification.

Egg shaped metal screen/sculpture notched to fit over wall, type SF-

Pre-cast concrete large pot/bowl on pedestal, type SF-16, as per the

diameter clay bowl set on 500mm diameter concrete base, 1250mm

diameter stainless steel bowl set on 750mm diameter concrete base,

20mm-100mm diameter gravel as per the Drawings and Specification.

9600mm diameter round pergola with BBQ, type BS-2, including but

not limited to barbecue counter with lockable ventilated steel access

diameterx500mm high tank) storage cabinet with lockable ventilated

Page 1361: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 1,452,080.00BF 1,452,080.00

FURNISHINGS Cont'd

1 Round pergola with BBQ, type BS-3, including but not limited to nr 1 57754.00 57,754.00

barbecue counter with lockable ventilated steel access door for

propane tank and automatic timer shut-off, stainless steel

professional-grade gas grill that also cooks with charcoal and wood,

cast brass dragon burners with a cooking heat at 25,000 btus each,

1000mm widex1200mm deepx1000mm High propane tank (400mm

steel access door, as per the Drawings and Specification.

2 nr 1 407660.00 407,660.00

BS-4, including but not limited to barbecue counter with lockable

ventilated steel access door for propane tank and automatic timer

shut-off, stainless steel professional-grade gas grill that also cooks

with charcoal and wood. cast brass dragon burners with a cooking

heat at 25,000 btus each. 1000mm widex1200mm deepx1000mm

High propane tank (400mm diameterx500mm high tank) storage

cabinet with lockable ventilated steel access door, as per the

diameterx500mm high tank) storage cabinet with lockable ventilated

Rectilinear pergola with BBQ and separate counter seating area, type

Page 1362: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Drawings and Specification.

3 nr 4 0.00

per the Drawings and SpecificaKon.

4 Small restroom, shower and pool equipment building, type BS-6, as nr 6 0.00

per the Drawings and SpecificaKon.

5 Large rectalinear pergola with BBQ, type BS-7, including but not nr 1 69211.00 69,211.00

limited to concrete column, steel beams, steel lattice, steel mesh,

steel ring, barbecue countertop, barbecue counter with lockable

ventilated steel access door for propane tank and automatic timer

shut-off, stainless steel professional-grade gas grill that also cooks

with charcoal and wood. cast brass dragon burners with a cooking

heat at 25,000 btus each, 1000mm widex1200mm deepx1000mm

High propane tank (400mm diameterx500mm high tank) storage

cabinet with lockable ventilated steel access door, as per the

Drawings and Specification.

CF 1,986,705.00BF 1,986,705.00

FURNISHINGS Cont'd

1 Small rectalinear pergola with BBQ, type BS-8, including but not nr 1 67949.00 67,949.00

limited to concrete column, steel beams, steel lattice, steel mesh,

steel ring, barbecue countertop, barbecue counter with lockable

ventilated steel access door for propane tank and automatic timer

shut-off, stainless steel professional-grade gas grill that also cooks

with charcoal and wood. cast brass dragon burners with a cooking

heat at 25,000 btus each, 1000mm widex1200mm deepx1000mm

High propane tank (400mm diameterx500mm high tank) storage

cabinet with lockable ventilated steel access door, as per the

Drawings and Specification.

2 9600mm diameter round pergola with Ppopane BBQ at palm court, nr 4 57754.00 231,016.00

type BS-9, including but not limited to barbecue counter with

Large restroom, Shower and pool equipment building, type BS-5, as

Page 1363: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

lockable ventilated steel access door for Propane tank and

automatic timer shut-off, stainless steel professional-grade gas grill

that also cooks with charcoal and wood. cast brass dragon burners

with a cooking heat at 25,000 btus each, 1000mm widex1200mm

deepx1000mm High propane tank (400mm diameterx500mm high

tank) storage cabinet with lockable ventilated steel access door, as

per the Drawings and Specification.

3 12600mm diameter round pergola at palm court, type BS-10, as per nr 1 85847.00 85,847.00

the Drawings and Specification.

4 9600mm diameter round pergola with BBQ, type BS-11, including nr 1 57754.00 57,754.00

but not limited to barbecue counter with lockable ventilated steel

access door for propane tank (400mm diameterx500mm high tank)

and automatic timer shut-off, stainless steel professional-grade gas

grill that also cooks with charcoal and wood. cast brass dragon

burners with a cooking heat at 25,000 btus each, as per the

Drawings and Specification.

5 11600mm diameter round pergola with BBQ, type BS-12, including nr 1 66004.00 66,004.00

but not limited to barbecue counter with lockable ventilated steel

steel professional-grade gas grill that also cooks with charcoal and

wood. cast brass dragon burners with a cooking heat at 25,000 btus

each, as per the Drawings and Specification.

CF 2,495,275.00BF 2,495,275.00

FURNISHINGS Cont'd

1 Large rectalinear pergola with BBQ, type BS-13, including but not nr 1 69211.00 69,211.00

limited to concrete column, steel beams, steel lattice, steel mesh,

steel ring, barbecue countertop, barbecue counter with lockable

ventilated steel access door for Propane tank and automatic timer

shut-off, stainless steel professional-grade gas grill that also cooks

with charcoal and wood. cast brass dragon burners with a cooking

access door for propane tank and automatic timer shut-off, stainless

Page 1364: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

heat at 25,000 btus each, as per the Drawings and Specification.

2 9600mm diameter round pergola with BBQ, type BS-14, including nr 1 57754.00 57,754.00

but not limited to barbecue counter with lockable ventilated steel

access door for propane tank (400mm diameterx500mm high tank)

and automatic timer shut-off, stainless steel professional-grade gas

grill that also cooks with charcoal and wood. cast brass dragon

and Specification.

3 11600mm diameter round pergola with BBQ, type BS-15, including nr 1 66004.00 66,004.00

but not limited to barbecue counter with lockable ventilated steel

steel professional-grade gas grill that also cooks with charcoal and

wood. cast brass dragon burners with a cooking heat at 25,000 btus

each, as per the Drawings and Specification.

4 Entry drop-off pavillion, type BS-16, including but not limited to nr 1 11149.00 11,149.00

and Specification.

5 Entry waiting area pavillion, type BS-17, including but not limited to nr 1 11149.00 11,149.00

steel poles, shade fabric with geo-textile fabric, as per the Drawings

and Specification

6 Entry waiting area pavillion, type BS-18, including but not limited to Item 1 11149.00 11,149.00

and Specification

7 13400mm diameter round pergola with BBQ, type BS-19, barbecue nr 2 73429.00 146,858.00

counter with lockable ventilated steel access door for propane tank

and automatic timer shut-off, stainless steel professional-grade gas

grill that also cooks with charcoal and wood. cast brass dragon

burners with a cooking heat at 25,000 btus each, as per the

Drawings and Specification.

8 Pergola at tennis courts, type BS-19, as per the Drawings and nr 1 161547.00 161,547.00

burners with a cooking heat at 25,000 btus each, as per the Drawings

access door for propane tank and automatic timer shut-off, stainless

Steel poles, shade fabric with geo-textile fabric, as per the Drawings

Steel poles, shade fabric with geo-textile fabric, as per the Drawings

Page 1365: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Specification.

CF 3,030,096.00BF 3,030,096.00

FURNISHINGS Cont'd

1 11600mm diameter round pergola with BBQ, type BS-21, including nr 3 66004.00 198,012.00

but not limited to barbecue counter with lockable ventilated steel

steel professional-grade gas grill that also cooks with charcoal and

wood. cast brass dragon burners with a cooking heat at 25,000 btus

each, as per the Drawings and Specification.

2 nr 4 97917.00 391,668.00

barbecue counter with lockable ventilated steel access door for

propane tank and automatic timer shut-off, stainless steel

professional-grade gas grill that also cooks with charcoal and wood.

cast brass dragon burners with a cooking heat at 25,000 btus each,

as per the Drawings and Specification.

3 Pergola in lounge area at hyper mart, type BS-23, including but not nr 1 53127.00 53,127.00

limited to 100mm thick granite cap at fireplace hearth, 30mm thick

sandstone cladding at fireplace hearth, concrete fire box, sandstone

column cladding - light color, sandstone column cladding - dark

in place concrete seat wall, water fountain, shade material

geotextile, as per the Drawings and Specification.

4 nr 2 24141.00 48,282.00

to metal frame with steel tubing, colorful metal pannels, tensile

shade material, as per the Drawings and Specification.

5 nr 2 40684.00 81,368.00

concrete seat wall, steel pergola, geotextile shade material, as per

the Drawings and Specification.

6 9600mm diameter round pergola with BBQ, type BS-26, including nr 5 60178.00 300,890.00

access door for propane tank and automatic timer shut-off, stainless

Rectlinear pergola with BBQ, type BS-22, including but not limited to

color, reinforced concrete column, CMU tapered screen wall, poured

Colorful play area screen walls, type BS-24, including but not limited

Outdoor fitness area, type BS-25, CMU screen walls, poured in place

Page 1366: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

but not limited to barbecue counter with lockable ventilated steel

access door for propane tank (40cm diameterx50cm high tank) and

automatic timer shut-off, stainless steel professional-grade gas grill

that also cooks with charcoal and wood. cast brass dragon burners

screen CMU wall, 450mm highx450mm wide CMU planter/seat wall

with granite cap, as per the Drawings and Specification.

CF 4,103,443.00BF 4,103,443.00

FURNISHINGS Cont'd

1 9600mm diameter round pergola with BBQ, type BS-27, including nr 2 57754.00 115,508.00

but not limited to barbecue counter with lockable ventilated steel

access door for propane tank (400mm diameterx500mm high tank)

and automatic timer Shut-off, stainless steel Professional-grade gas

grill that also cooks with charcoal and wood. cast brass dragon

burners with a cooking heat at 25,000 btus each, as per the

Drawings and Specification.

2 Two tiered round pergola with BBQ, type BS-28, including but not nr 1 86355.00 86,355.00

limited to barbecue counter with lockable ventilated steel access

door for propane tank (400mm diameterx500mm high tank) and

automatic timer shut-off, stainless steel, professional-grade gas grill

that also cooks with charcoal and wood. cast brass dragon burners

with a cooking heat at 25,000 btus each, 450mm highx450mm wide

seat CMU wall, as per the Drawings and Specification.

3 Triangular shaped shade pergola, type BS-29, as per the Drawings nr 1 101858.00 101,858.00

and Specification.

4 9600mm diameter round pergola with BBQ, type BS-30, including nr 1 57754.00 57,754.00

but not limited to barbecue counter with lockable ventilated steel

access door for propane tank (400mm diameterx500mm high tank)

and automatic timer shut-off, stainless steel professional-grade gas

grill that also cooks with charcoal and wood. cast brass dragon

with a cooking heat at 25,000 btus each, 1600mm highx200mm wide

Page 1367: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

burners with a cooking heat at 25,000 btus each, as per the

Drawings and Specification.

5 Type BS-31, as per the Drawings and Specification. nr 1 59243.00 59,243.00

Total for FURNISHING

CARRIED TO SUMMARY US Dollar 4,524,161.00

13 00 00 SPECIAL CONSTRUCTION

13 12 00 Fountains

Notwithstanding the provisions of the Standard Method of

giving the plan area and the depth variation. The Contractor is to

include all costs for the provision of such pools including warranties.

No claim for lack or want of information shall be entertained

As per GOSI approval, all swimming pools, jacuzzis and water

features including adjacent walls and perimeter drains are to be

designed by Holdenwater. Contractors are to contact Holdenwater

at ([email protected]) prior to submitting bids, to obtain

projected materials costs. The Consultant is to provide collateral

limited to excavation and disposal. concrete works including water

stops, masonry, thermal and moisture protection, finishes,

equipment, plumbing including pump and filtering mechanisms,

heating, electrical and utilities. The Contractor is to also include for

any ancillary buildings associated with the swimming pools and

jacuzzis and is to include such spare parts as to ensure quiet and

unfettered enjoyment of the swimming pools and jacuzzis facilities.

Measurement, swimming pools and jacuzzis have been enumerated

warranties to GOSI por the provision of such services. The Contractor

is to construct these swimming pools and jacuzzis, including, but not

All items hereunder to be completed as per the Drawings nr LSHP003,

LS-HP100, LS-HP101, LS-HP102, LS-HP103, LS-HP104, LSHP105,

LS-HP106, LS-HP107, LS-HP108, LS-HP109, LS-HP110, LSHP111,

LS-HP112, LS-HP113, LS-HP114, LS-HP115, LS-HP116, LSHP117,

Page 1368: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

LS-HP218, LS-HP219, LS-HP220, LS-HP221, LS-HP222, and

Specification.

1 Design, supply, construct, test and commission the water feature at nr 1 72950.00 72,950.00

Palm court, type WF-8, including but limited to fountain exterior

as per the Drawings and Specification.

2 Design, supply, construct, test and commission the water feature at nr 1 82795.00 82,795.00

recreation building courtyard, type WF-13, including but not limited

to fountain wall, seat wall, fountain tile with ceramic tiles, fountain

boulders, as per the Drawings and Specification.

CF 155,745.00BF 155,745.00

SPECIAL CONSTRUCTION Cont'd

1 Design, supply, construct, test and commission the main entry nr 2 88424.00 176,848.00

fountain, type WF-16, including but limited to 45cm high seat wall

with rendered exterior finish, granite cap, central fountain

wall/spillway with glass tiles, granite cap, as per the Drawings and

Specification.

2 Design, supply, construct, test and commission the side entry nr 2 64855.00 129,710.00

LS-HP118, LS-HP119, LS-HP120, LS-HP121, LS-HP122, LSHP123,

LS-HP124, LS-HP201, LS-HP202, LS-HP203, LS-HP204, LSHP205,

LS-HP206, LS-HP207, LS-HP208, LS-HP209, LS-HP210, LSHP211,

LS-HP212, LS-HP213, LS-HP214, LS-HP215, LS-HP216, LSHP217,

rendered finish, granite Fountain cap, fountain tile with ceramic tiles,

Page 1369: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

fountain, type WF-17, including but limited to 45cm High seat wall

with rendered exterior finish, granite cap, Central fountain

wall/spillway with glass tiles, granite cap, high back fountain wall

with glass tile as per the Drawings and Specification.

3 Design, supply, construct, test and commission the fountain at nr 2 105171.00 210,342.00

serviced apartments, type WF-18, including but limited to glazed

ceramic fountain tile, planter wall/ fountain back wall with glazed

ceramic tile and granite cap, as per the Drawings and Specification.

Total for SPECIAL CONSTRUCTION

CARRIED TO SUMMARY US Dollar 672,645.00

32 00 00 EXTERIOR IMPROVEMENTS

and Specification.

32 14 00 Unit Paving

1 P-1; Random shaped, light beige color, semi polished, 60 mm thick m2 2,209 339.00 748,851.00

sandstone with 10 - 15 mm diameter white pebbles in between

stone as per Contract Drawings and Specifications

2 P-2; 800 mm x 200 mm x 40 mm thick light brown color polished m2 617 529.00 326,393.00

finish burned granite tiles/frey color honed finish glazed granite tiles

as per Contract Drawings and Specifications

3 P-3; Mixed color, solid pattern PU Tartan at playgrounds as per m2 136 0.00

All items hereunder to be completed as per the Drawings nr LSHP001,

LS-HP002, LS-HP100, LS-HP101, LS-HP102, LS-HP103, LSHP104,

LS-HP105, LS-HP106, LS-HP107, LS-HP108, LS-HP109, LSHP110,

LS-HP111, LS-HP112, LS-HP113, LS-HP114, LS-HP115, LSHP116,

LS-HP117, LS-HP118, LS-HP119, LS-HP120, LS-HP121, LSHP122,

LS-HP123, LS-HP124, LS-HP201, LS-HP202, LS-HP203, LSHP204,

LS-HP205, LS-HP206, LS-HP207, LS-HP208, LS-HP209, LSHP210,

LS-HP211, LS-HP212, LS-HP213, LS-HP214, LS-HP215, LSHP216,

LS-HP217, LS-HP218, LS-HP219, LS-HP220, LS-HP221, LSHP222

Page 1370: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Contract Drawings and Specifications

4 P-4; Dark orange color, solid pattern PU Tartan at sport courts area m2 3,316 0.00

as per Contract Drawings and Specifications

5 P-5; 150 mm thick, retardant finish, natural color, rectilinear tiles as m2 51,273 59.00 3,025,107.00

per Contract Drawings and Specifications

6 m2 7,790 59.00 459,610.00

Contract Drawings and Specifications

7 P-7; 50 mm thick, retardant finish, dark brown color, hexagonal m2 3,376 50.00 168,800.00

interlocking pavers set on 70 mm thick compact sand leveling bed

over 350 mm thick compacted aggregate crushed stone on

compacted soil as per Contract Drawings and Specifications

8 m2 12,910 48.00 619,680.00

various colors, artificial wood planks coated with a transparent matt

weather proof coating as per Contract Drawings and Specifications

9 P-9; 300 mm - 590 mm thick clean sand for playground area as per m2 2,512 42.00 105,504.00

Contract Drawings and Specifications

CF 5,453,945.00BF 5,453,945.00

Exterior Improvements Cont'd

10 P-10; 200 mm x 90 mm x 60 mm thick Herringbone pattern, brown m2 9,677 48.00 464,496.00

color, retardant finish rectangular interlocking pavers set on 70 mm

thick compact sand leveling bed 350 mm thick over compacted

and Specifications

11 P-11; 100 mm x 100 mm x 40 mm thick linear pattern, dark brown nr 36,033 6.00 216,198.00

Contract Drawings and Specifications

1 P-12; 200 mm x 100 mm x 40 mm thick linear pattern, light beige nr 32,762 2.00 65,524.00

P-6; 150 mm thick, retardant finish, gray color, rectilinear tiles as per

As per Q&A No. 385, we consider precast concrete paver similar to P-10)P-8; 100 mm x 150 mm x 40 mm thick running bond, retardant finish,

aggregate crushed stone on compacted soil as per Contract Drawings

color, honed finish local stone laid on 40 mm thick mortar bed as per

Page 1371: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

bed as per Contract Drawings and Specifications

2 P-13; 150 mm thick natural colour, broom finish/ retardant finish, m2 1,062 59.00 62,658.00

3 m2 140 59.00 8,260.00

32 18 00 Athletic and Recreational Surfacing

5 Bocce court, type SF-4, as per the Drawings and Specification nr 2 28087.00 56,174.00

6 Tennis court (2nr) with chain link fence and gates per International nr 1 206119.00 206,119.00

tennis association standards. provide wind screens on (3) exposed

sides, type BS-20, including but not limited to chain link fence set in

continuous concrete footing, galvanised chain on broom finish curb,

as per the Drawings and Specification.

7 Basketball court, type SF-6, including but not limited to chain link nr 2 115455.00 230,910.00

fence, concrete curb/continuous fence footing, bench, as per the

Drawings and Specification

8 Football pitch, grass including drainage, line marking and nets; nr 1 178240.00 178,240.00

overall area as per the Drawings & Specification.

CF 6,942,524.00BF 6,942,524.00

Exterior Improvements Cont'd

color, retardant finish interlocking pavers laid on 40 mm thick mortar

slab on grade concrete as per Contract Drawings and Specifications

P-14; 200 mm x 100 mm x 150 mm thick gray color, retardant finish,

concrete stepping stones as per Contract Drawings and Specifications

(As per Q&A no. 438 refer to specification section 321800 used sandfill not grass)

Page 1372: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

32 31 00 Fences and Gates

2 nr 1 51515.00 51,515.00

and Specification.

3 Swing gates with lockable latch and cane bolts on each gate to hold nr 2 11104.00 22,208.00

open and secure closed, type G-2, as per the Drawings and

Specification.

4 nr 1 51515.00 51,515.00

and Specification.

32 93 43 Trees

LS-PP124 and Specifications.

5 Bauhinia purpurea / Purple bauhinia, total height 4m, branching nr 219 501.00 109,719.00

height 2.25m, spread radius 2.5m, code - T1

6 Brachychiton discolor / Lacebark Tre, total height 4m, branching nr 42 501.00 21,042.00

height 2.5 - 3.0m, spread radius 1.5m, code - T2

7 Ficus lyrata / The fiddle-leaf fig, total height 3.5m, branching height nr 90 460.00 41,400.00

2.25m, spread radius 1.5m, code - T3

8 Prosopis alba / algarrobo blanco, total height 3m, spread radius nr 84 390.00 32,760.00

1.5m, code - T4

9 nr 206 390.00 80,340.00

2.25m, spread radius 1.5m, code - T5

10 Ficus infectoria/ Latin ficus, total height 4m, branching height nr 234 596.00 139,464.00

2.25m, spread radius 2m, code - T6

11 Ficus irregularis/ Ficus amstel queen, total height 3m, spread radius nr 166 557.00 92,462.00

Sliding metal gate with lockable latch, type G-1, as per the Drawings

Sliding metal gate with lockable latch, type G-3, as per the Drawings

All planting (Trees & palms) works hereunder to be completed as per

the Drawings nr LS-PP001, LS-PP100, LS-PP101, LS-PP102, LS-PP103,

LS-PP104, LS-PP105, LS-PP106, LS-PP107, LS-PP108, LS-PP109, LSPP110,

LS-PP111, LS-PP112, LS-PP113, LS-PP114, LS-PP115, LS-PP116,

LS-PP117, LS-PP118, LS-PP119, LS-PP120, LS-PP121, LS-PP122, LSPP123,

Pongamia pinnata / Karam Oiltree, total height 3m, branching height

Page 1373: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1.5m, code - T7

12 Grevillea robusta / Silky oak, total height 3m, branching height 2m, nr 163 557.00 90,791.00

spread radius 1.5m, code - T8

CF 7,675,740.00BF 7,675,740.00

Exterior Improvements Cont'd

1 Albizia julibrissin / Persian silk, total height 4m, branching height nr 125 501.00 62,625.00

2.25m, spread radius 2m, code - T9

2 Bombax ceiba / Cotton tree, total height 5m, branching height 2.5 - nr 80 836.00 66,880.00

3m, spread radius 2.5m, code - T10

3 Callistemon viminalis / Weeping Bottlebrush, total height 2m, nr 171 429.00 73,359.00

spread radius 1.25m, code - T11

4 Erythrina crista-galli / Cockspur Coral Tree, total height 4m, nr 155 429.00 66,495.00

branching height 2.5m, spread radius 2m, code - T12

5 Ficus Benjamina / Weeping fig, total height 3m, branching height nr 77 501.00 38,577.00

0.5m, spread radius 0.75m, code - T13

6 Koelreuteria paniculata / Goldenrain tree, total height 3m, nr 45 501.00 22,545.00

branching height 2m, spread radius 2m, code - T14

7 Punica granatum / The pomegranate, total height 3m, branching nr 104 431.00 44,824.00

height 2m, spread radius 1.5m, code - T15

8 Schinus molle / American pepper, total height 2.5m, spread radius nr 142 431.00 61,202.00

1.25m, code - T16

9 Acacia farnesiana / Needle bush, total height 2.5m, spread radius nr 112 431.00 48,272.00

Page 1374: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1.5m, code - T17

10 Cassia fistula / Golden Shower Tree, total height 4m, branching nr 191 524.00 100,084.00

height 2.25m, spread radius 2m, code - T18

11 Ceratonia siliqua / Carob Tree, total height 2.5m, branching height nr 76 516.00 39,216.00

1m, spread radius 1m, code - T19

12 Conocarpus erectus / Silver-leaved Buttonwood, total height 4m, nr 50 298.00 14,900.00

spread radius 2m, code - T20

13 nr 72 390.00 28,080.00

spread radius 2m code - T21

14 Ficus microcarpa hawaii / Ficus hawaii, total height 2.5m, branching nr 156 390.00 60,840.00

height 1.5m, spread radius 0.75m, code - T22

CF 8,403,639.00BF 8,403,639.00

Exterior Improvements Cont'd

1 Markhamia stipulata, total height 3.5m, branching height 2.25m, nr 171 412.00 70,452.00

spread radius 2m, code - T23

2 Parkinsonia aculeata / palo verde, total height 3m, spread radius nr 39 404.00 15,756.00

2m, code - T24

3 Tabebuia argentea, total height 3m, spread radius 2m, code - T25 nr 167 446.00 74,482.00

4 Citrus limon / Lemon Tree, total height 3.5m, spread radius 2.5m, nr 5 725.00 3,625.00

code - T26

5 nr 12 557.00 6,684.00

2.5-3m, spread radius 2m, code - T27

6 Hibiscus tilliaceus / Sea Hibiscus, total height 4m, branching height nr 25 390.00 9,750.00

2m, spread radius 2m, code - T28

7 Khaya senegalensis/ African mahogany, total height 3m, branching nr 13 640.00 8,320.00

height 2.25m, spread radius 2m, code - T29

Ficus religiosa / Bo-Tree, total height 3.5m, branching height 2.25m,

Chorisia speciosa \ Ceiba speciosa, total height 4m, branching height

Page 1375: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

8 Plumeria obtusa / white frangipani, total height 1.5m, spread radius nr 8 318.00 2,544.00

1m, code - T30

9 Spathodea campanulata / Fountain Tree, total height 4m, branching nr 7 696.00 4,872.00

height 2.5m, spread radius 2.5m, code - T31

10 Terminalia catappa / Bengal almond, total height 4m, branching nr 10 446.00 4,460.00

height 2.5m, spread radius 2.5m, code - T32

11 Thespesia populnea / Portia Tree, total height 4m, branching height nr 15 446.00 6,690.00

2.5m, spread radius 2.5m, code - T33

12 Thevetia peruviana / Yellow Oleander, total height 2.5m, spread nr 19 446.00 8,474.00

radius 1.5m, code - T34

13 Olea europaea / Olive Tree, total height 3m, spread radius 2.5m, nr 5 1617.00 8,085.00

code - T35

14 Pinus halepensis / Aleppo Pine, total height 2.5m, spread radius nr 9 418.00 3,762.00

1.5m, code - T36

CF 8,631,595.00BF 8,631,595.00

Exterior Improvements Cont'd

Page 1376: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1 Ziziphus spina-christi / Christ's Thorn Jujube, total height 3.5m, nr 9 407.00 3,663.00

branching height 2m, spread radius 2m, code - T37

Palms

2 Phoenix dactylifera / Date Palm, trunk height 4m, code - P1 nr 461 1840.00 848,240.00

3 Oreodoxa regia / Roystonea regia, trunk height 4m, code - P2 nr 73 1986.00 144,978.00

4 Washingtonia filifera / California Fan Palm, trunk height 4m, code - nr 131 2444.00 320,164.00

P3

5 nr 29 3936.00 114,144.00

- P4

6 nr 12 1261.00 15,132.00

7 Cycas revoluta / Sago Palm, trunk height 0.5m, code - P6 nr 30 1010.00 30,300.00

8 Pandanus veitchii / Thatch Screwpine, total height 1m, code - P7 nr 13 1010.00 13,130.00

9 nr 24 1010.00 24,240.00

10 Dasylirion serratifolium / Taxonomies, total height 1m, code - P9 nr 8 1819.00 14,552.00

11 Yucca aloifolia / Spanish bayonet, total height 1.5m, code - P10 nr 4 1261.00 5,044.00

CF 10,165,182.00BF 10,165,182.00

Exterior Improvements Cont'd

32 93 33 Shrubs

LS-PP300 and Specifications.

Phoenix canariensis / Canary Island Date Palm, trunk height 2m, code

Chrysalidocarpus lutescens / Areca Palm, total height 2m, code - P5

Dracena draco/The Canary Islands dragon, total height 2m, code - P8

All planting works hereunder to be completed as per the Drawings nr

LS-PP001, LS-PP200, LS-PP201, LS-PP202, LS-PP203, LS-PP204, LSPP205,

LS-PP206, LS-PP207, LS-PP208, LS-PP209, LS-PP210, LS-PP211,

LS-PP212, LS-PP213, LS-PP214, LS-PP215, LS-PP216, LS-PP217, LSPP218,

LS-PP219, LS-PP220, LS-PP221, LS-PP222, LS-PP223, LS-PP224,

Page 1377: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1 Acocanthera spectabilis, total height 500mm, spread 500mm, pot nr 18,112 23.00 416,576.00

size 25, 4 nr/Sqm

2 Atriplex halimus / Mediterranean Saltbush, total height 600mm, nr 3,914 20.00 78,280.00

spread 400mm, pot size 25, 4 nr/Sqm

3 Bougainvillea glabra, total height 400mm, spread 500mm, pot size nr 35,242 23.00 810,566.00

25, 4 nr/Sqm

4 Breynia nivosa, total height 500mm, spread 300mm, 4 nr/Sqm nr 13,842 22.00 304,524.00

5 Brunfelsia pauciflora, total height 600mm, spread 400mm, 1 nr/Sqm nr 352 21.00 7,392.00

6 Cestrum nocturnum / Raatraani, total height 1000mm, spread nr 3,236 22.00 71,192.00

500mm, pot size 30, 2 nr/Sqm

7 Crinum asiaticum / Spider Lily, total height 750mm, spread 600mm, nr 1,371 55.00 75,405.00

pot size 40, 2 nr/Sqm

8 Cuphea hyssopifolia, total height 600mm, spread 400mm, pot size nr 1,790 26.00 46,540.00

30, 4 nr/Sqm

9 Hibiscus syriacus, total height 500mm, spread 400mm, 4 nr/Sqm nr 14,039 21.00 294,819.00

10 nr 1,374 23.00 31,602.00

400mm, 2 nr/Sqm

11 Nerium oleander / Oleander, total height 750mm, spread 500mm, 1 nr 920 22.00 20,240.00

nr/Sqm

CF 12,322,318.00BF 12,322,318.00

Exterior Improvements Cont'd

1 Polygala myrtifolia, total height 400mm, spread 200mm, 4 nr/Sqm nr 6,568 26.00 170,768.00

2 nr 1,120 20.00 22,400.00

3 nr 6,928 23.00 159,344.00

Leucophyllum frutescens / Texas Ranger, total height 600mm, spread

Solanum rantonnetii, total height 1000mm, spread 400mm, 4 nr/Sqm

Acalypha welkesiana, total height 800mm, spread 400mm, 4 nr/Sqm

Page 1378: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

4 Amaranthus tricolor, total height 800mm, spread 400mm, 1 nr/Sqm nr 1,158 20.00 23,160.00

5 nr 1,406 24.00 33,744.00

25, 0.5 nr/Sqm

6 nr 3,753 20.00 75,060.00

7 nr 1,996 23.00 45,908.00

2 nr/Sqm

8 nr 5,064 23.00 116,472.00

30, 4 nr/Sqm

9 nr 1,655 22.00 36,410.00

1 nr/Sqm

10 Jatropha integerrina, total height 800mm, spread 400mm, pot size nr 863 24.00 20,712.00

20, 1 nr/Sqm

11 Lantana camara red, total height 200mm, spread 200mm, pot size nr 10,986 22.00 241,692.00

20, 4 nr/Sqm

12 Malvaviscus arboreus, total height 500mm, spread 400mm, pot size nr 1,131 23.00 26,013.00

30, 2 nr/Sqm

13 nr 6,662 21.00 139,902.00

2 nr/Sqm

14 nr 1,496 20.00 29,920.00

20, 4 nr/Sqm

CF 13,463,823.00BF 13,463,823.00

Exterior Improvements Cont'd

1 nr 18,908 20.00 378,160.00

2 nr/Sqm

2 nr 10,899 23.00 250,677.00

nr/Sqm

Caesalpinia pulcherima, total height 500mm, spread 500mm, pot siz

Calliandra californica, total height 400mm, spread 400mm, 4 nr/Sqm

Cestrum elegans, total height 1000mm, spread 500mm, pot size 30,

Hibiscus rosa-sinensis, total height 500mm, spread 400mm, pot size

Ixora coccinea red, total height 400mm, spread 400mm, pot size 20,

Muraya paniculata, total height 400mm, spread 500mm, pot size 20,

Russelia equisetiformis, total height 400mm, spread 400mm, pot size

Carissa grandiflora, total height 600mm, spread 600mm, pot size 40,

Cestrum parqui, total height 1000mm, spread 500mm, pot size 30, 2

Page 1379: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3 nr 288 26.00 7,488.00

nr/Sqm

4 Duranta repens, total height 300mm, spread 300mm, pot size 20, 6 nr 2,604 21.00 54,684.00

nr/Sqm

5 Euonymus japonicus, total height 300mm, spread 300mm, pot size nr 5,669 26.00 147,394.00

20, 6 nr/Sqm

6 nr 12,079 23.00 277,817.00

nr/Sqm

7 nr 6,074 23.00 139,702.00

nr/Sqm

8 nr 315 24.00 7,560.00

1 nr/Sqm

9 nr 1,294 24.00 31,056.00

2 nr/Sqm

10 Tecoma stans, total height 1000mm, spread 700mm, pot size 40, 1 nr 2,646 22.00 58,212.00

nr/Sqm

11 Alcea rosea, total height 300mm, spread 300mm, pot size 20, 6 nr 2,372 22.00 52,184.00

nr/Sqm

12 Myrtus communis, total height 500mm, spread 300mm, pot size 20, nr 231 23.00 5,313.00

1 nr/Sqm

13 Strelitzia riginae, total height 800mm, spread 800mm, pot size 50, 1 nr 562 55.00 30,910.00

nr/Sqm

14 nr 222 55.00 12,210.00

nr/Sqm

CF 14,917,190.00BF 14,917,190.00

Exterior Improvements Cont'd

Datura arborea, total height 1000mm, spread 600mm, pot size 40, 1

Euryops acraeus, total height 300mm, spread 300mm, pot size 20, 6

Euryops pectnatus, total height 300mm, spread 300mm, pot size 20, 6

Jasminum sambac, total height 600mm, spread 400mm, pot size 30,

Pittosporum tobira, total height 400mm, spread 400mm, pot size 30,

Taberna montana, total height 500mm, spread 500mm, pot size 30, 1

Page 1380: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1 nr 2,187 22.00 48,114.00

2 nr/Sqm

2 Pennisetum rubrum, total height 400mm, spread 400mm, pot size nr 14,118 20.00 282,360.00

25, 6 nr/Sqm

32 93 13 Ground Covers

LS-PP300 and Specifications.

3 Asparagus densiflorus / Foxtail Fern, total height 300mm, spread nr 21,207 12.00 254,484.00

300mm, pot size 20, 8 nr/Sqm

4 Aptenia cordifolia, total height 200mm, spread 300mm, pot size 20, nr 23,624 12.00 283,488.00

8 nr/Sqm

5 Coleus punilus, total height 300mm, spread 200mm, pot size 20, 8 nr 9,619 13.00 125,047.00

nr/Sqm

6 Agapanthus africanus, total height 500mm, spread 300mm, pot size nr 2,290 13.00 29,770.00

20, 2 nr/Sqm

7 Heliotropium arboresens, total height 200mm, spread 200mm, pot nr 21,427 12.00 257,124.00

size 20, 8 nr/Sqm

8 Hymenocallis festalis, total height 500mm, spread 300mm, pot size nr 1,503 12.00 18,036.00

20, 2 nr/Sqm

9 nr 84,988 13.00 1,104,844.00

20, 8 nr/Sqm

10 Lantana montevedensis, total height 200mm, spread 200mm, pot nr 13,813 13.00 179,569.00

size 20, 8 nr/Sqm

11 nr 20,368 13.00 264,784.00

Tecomaria capensis, total height 300mm, spread 300mm, pot size 20,

All planting works hereunder to be completed as per the Drawings nr

LS-PP001, LS-PP200, LS-PP201, LS-PP202, LS-PP203, LS-PP204, LSPP205,

LS-PP206, LS-PP207, LS-PP208, LS-PP209, LS-PP210, LS-PP211,

LS-PP212, LS-PP213, LS-PP214, LS-PP215, LS-PP216, LS-PP217, LSPP218,

LS-PP219, LS-PP220, LS-PP221, LS-PP222, LS-PP223, LS-PP224,

Lavandula atriplicifolia, total height 300mm, spread 200mm, pot size

Plumbago capensis, total height 300mm, spread 200mm, pot size 20,

Page 1381: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

8 nr/Sqm

CF 17,764,810.00BF 17,764,810.00

Exterior Improvements Cont'd

1 Rhoeo discolor, total height 100mm, spread 200mm, pot size 20, 8 nr 6,543 12.00 78,516.00

nr/Sqm

2 nr 10,101 12.00 121,212.00

nr/Sqm

3 nr 4,119 13.00 53,547.00

pot size 20, 8 nr/Sqm

4 nr 10,138 11.00 111,518.00

8 nr/Sqm

5 nr 14,574 13.00 189,462.00

20, 8 nr/Sqm

6 nr 4,573 11.00 50,303.00

20, 8 nr/Sqm

7 Hippeastrumx john sonii, total height 300mm, spread 200mm, pot nr 5,906 12.00 70,872.00

size 20, 8 nr/Sqm

8 Irsine herbstii, total height 300mm, spread 200mm, pot size 20, 8 nr 6,968 12.00 83,616.00

nr/Sqm

9 Catharanthus roseus, total height 300mm, spread 200mm, pot size nr 30,981 11.00 340,791.00

20, 8 nr/Sqm

10 nr 15,415 11.00 169,565.00

nr/Sqm

12 Pentas lanceolata red, total height 200mm, spread 200mm, pot size nr 23,681 12.00 284,172.00

20, 8 nr/Sqm

13 Pelargonium grandiflorum, total height 300mm, spread 200mm, pot nr 12,645 12.00 151,740.00

size 20, 8 nr/Sqm

Verbena hybrida, total height 100mm, spread 200mm, pot size 20, 8

Scaevola aemula / blue wonder, total height 100mm, spread 200mm,

Setcresea purpurea, total height 100mm, spread 200mm, pot size 20,

Rosmarinus officinallis, total height 300mm, spread 200mm, pot size

Althernathera arnoena, total height 300mm, spread 200mm, pot size

Lampranthus red, total height 300mm, spread 200mm, pot size 20, 8

Page 1382: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

14 Pelargonium zonale, total height 300mm, spread 200mm, pot size nr 47,714 12.00 572,568.00

20, 8 nr/Sqm

15 Arcotits hybrids red, total height 300mm, spread 200mm, pot size nr 8,475 12.00 101,700.00

20, 8 nr/Sqm

CF 20,144,392.00BF 20,144,392.00

Exterior Improvements Cont'd

1 nr 4,886 12.00 58,632.00

8 nr/Sqm

2 Achillea bibersteinii, total height 300mm, spread 200mm, pot size nr 23,838 12.00 286,056.00

20, 8 nr/Sqm

3 Abutilon pannosum, total height 300mm, spread 200mm, pot size nr 23,747 12.00 284,964.00

20, 8 nr/Sqm

4 nr 14,058 12.00 168,696.00

20, 8 nr/Sqm

5 nr 39,168 12.00 470,016.00

8 nr/Sqm

6 nr 13,149 12.00 157,788.00

20, 8 nr/Sqm

7 Anthemis spp. Yellow, total height 300mm, spread 200mm, pot size nr 16,107 13.00 209,391.00

20, 8 nr/Sqm

Desert planting Areas

8 m2 5,280 34.00 179,520.00

Sensevieria trifasciata / Snake Plant fully compliance with the

Drawings and Specification

Lawn Areas

Clianthus formosus, total height 300mm, spread 200mm, pot size 20,

Arctotis hybrids yellow, total height 300mm, spread 200mm, pot size

Gazania splendens, total height 100mm, spread 200mm, pot size 20,

Sanvitalia Procumbens, total height 100mm, spread 200mm, pot size

Desert planting with Euphorbia milli, Echino cactus, Agave attenuata

/ Agave, Agave attenuata / Agave, Pedilanthus tithymaloides / Buckthorn,

Page 1383: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

9 Bouteloua dactyloides / American Buffalo grass for Lawn Areas m2 19,706 31.00 610,886.00

Gravel

10 m2 15,838 5.00 79,190.00

thick layed on a min. of 300mm depth of sand in all desert/succlent

planting area

Total for EXTERIOR IMPROVEMENTS

CARRIED TO SUMMARY US Dollar 22,649,531.00

POOL HOUSES (10nr)

03 00 00 CONCRETE

Notwithstanding the Provisions of the Standard Method of

Measurement of Building Works Seventh Edition, 1988 (SMM7) the

following concrete works are measured m3/m including

reinforcement bars and formworks. The Contractor is to include for

costs of reinforcement and formwork with concrete works. No

additional charge or cost for reinforcement and formwork separately

will be entertained due to lack or want of knowledge.

All concrete works herein shall be completed in full compliance with

the Drawings and Specification.

03 11 13 Structural Cast-in-Place Concrete Forming

1 Plain Concrete 20 Mpa, for blinding Beds, Thickness ≤ 150mm, m3 84 188.00 15,792.00

poured against the compacted soil, as stated in the Structural Notes

and Specification.

03 31 00 Structural Concrete

2 Reinforced concrete beds 35 MPa for slab with A393 welded wire m3 508 458.00 232,664.00

and Specification.

75% Gravel, 30:50 mm dim. Decorative gravel mulch layer of 100 mm

mesh, on grade; thickness ≤ 150mm, poured against the compacted

soil; kind, quality, curing details etc. as stated in the Structural Notes

Page 1384: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3 Reinforced concrete 35 MPa for superstructure slabs, thickness m3 581 734.00 426,454.00

250mm; kind, quality, curing details etc. as stated in the Structural

Notes and Specification.

03 30 53 - Miscellaneous Cast-in-situ Concrete

4 300mm wide x 200mm high reinforced concrete 35 Mpa for lintel m 168 32.00 5,376.00

CF 680,286.00BF 680,286.00

Pool Houses (10nr) Cont'd

03 53 00 Concrete Topping

1 m2 1,394 17.00 23,698.00

kind, quality, composition, mix, materials, nature of base, method of

construction, layout and treatments, thermal insulation, moisture

resistant treatment, method of jointing, etc. as per the Drawings and

Specification).

2 Sealed concrete for roof and water tank areas, width > 300mm, m2 1,394 17.00 23,698.00

(thickness, kind, quality, composition, mix materials, nature of base,

Sand cement/concrete screed for floors, width > 300mm, (thickness,

Page 1385: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

method of construction, layout and treatments, thermal insulation,

moisture resistant treatment, method of jointing, etc. as per the

Drawings and Specification).

04 00 00 - Masonry

All Masonry works herein shall be completed full incompliance with

the Drawings and Specification.

04 22 00 - Concrete Unit Masonry

Internal walls and Partitions

3 200mm thick CMU wall reinforced, vertical, (kind, quality and size of m2 338 39.00 13,182.00

blocks, type of bond, mix of motar etc. to be included as per the

Specification)

4 100mm thick CMU wall reinforced, vertical, (kind, quality and size of m2 635 34.00 21,590.00

blocks, type of bond, mix of motar etc. to be included as per the

Specification)

External walls

5 300mm thick CMU wall, vertical, comprised with 150mm block work m2 1,064 83.00 88,312.00

external side, 50mm insulation, 100mm block work internal side,

included as per the details and Specification )

Additional Items

6 The Contractor is to list here and price any items shown on the Drawings, mentioned in the

Specifications or required for the satisfactory completion of this section, but not mentioned

here. Any such items not listed below shall be deemed to be included. item

05 00 00 METALS

6.1 Aluminium powder coated pergola m2 672 181.00 121,632.00

(kind, quality and size of blocks, type of bond, mix of motar etc. to be

Page 1386: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 972,398.00BF 972,398.00

Pool Houses (10nr) Cont'd

06 00 00 WOOD, PLASTICS, AND COMPOSITES

06 61 16 Solid Surfacing Fabrications

1 Supply and fix solid acrylic counter top shaped 2150 long 575mm m2 20 722.00 14,440.00

wide with openings for 2nr wash basins

2 Supply and fix solid acrylic counter top shaped 1500 long 575mm m2 10 487.00 4,870.00

wide with opening for 1nr wash basins

07 00 00 THERMAL AND MOISTURE PROTECTION

07 10 00 Damp proofing and Waterproofing

Substructure Waterproofing

All works herein shall be completed in full compliance with the

Drawings and Specification.

3 Waterproofing works for substructure with two coats of bitumen m2 171 5.00 855.00

paint, vertical surface, width > 300mm(kind, quality, method of

application, thickness as per the Drawings and Specification).

4 Waterproofing works for substructure with vapour barrier 250 m2 1,452 2.00 2,904.00

microns, horizontal surface, width > 300mm, (kind, quality, method

of fixing, thickness as per the Drawings and Specification).

5 50mm thick protection screed for water horizontal proofing works, m2 1,452 12.00 17,424.00

Drawings and Specification).

Wet Area Waterproofing / Roof Waterproofing

6 Waterproofing works for wet area, vertical surface, width > 300mm, m2 1,341 22.00 29,502.00

1200mm high, (kind, quality, method of fixing, thickness as per the

Drawings and Specification)

width > 300mm, (kind, quality, method of fixing, thickness as per the

Page 1387: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 1,042,393.00BF 1,042,393.00

Pool Houses (10nr) Cont'd

1 Waterproofing works for wet area, horizontal surface, width > m2 640 22.00 14,080.00

300mm (kind, quality, method of fixing, thickness as per the

Drawings and Specification)

2 Waterproofing membrane for roof and balcony, horizontal surface, m2 1,452 37.00 53,724.00

Drawings and Specification)

3 Geotextile layer for roof and balcony water proofing works, m2 1,452 3.00 4,356.00

horizontal surface, width > 300mm, (kind, quality, method of fixing,

thickness as per the Drawings and Specification)

4 100mm thick insulation for water proofing works at roof and balcony m2 1,452 23.00 33,396.00

water proofing works, horizontal surface, width > 300mm, (kind,

quality, method of fixing, thickness as per the Drawings and

Specification)

08 00 00 OPENINGS

& Windows Schedule Drawings A0-A801, A0-A802, A0-A803 and

Specification.

Note: Notwithstanding the Provisions of the Standard Method of

Measurement, door sets including doors, frames, vision panels,

decoration and ironmongery have been measured as a composite

and Specification. No claim for lack or want of knowledge will be

entertained

08 14 00 - Wood Doors

5 Supply and fix wooden flush decorative teak veneer door, 44mm nr 90 1012.00 91,080.00

thick, 900mm wide x 2200mm high including frame, type D2,

finished with and including paint, all accessories and hardware

including but not limited to hinges BBS type,thumbturn and

width > 300mm, (kind, quality, method of fixing, thickness as per the

All works herein shall be completed in full compliance with the Doors

item and the Contractor should make due reference to the Drawings

Page 1388: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

indicator, lever handles and latch, wall stop, roses as stated on the

Drawings and in the Specification.

08 51 13 Aluminum Windows

6 Supply and fix aluminium double glazed window, 1400mm wide x nr 140 304.00 42,560.00

limited to hinges, handle, lock, weather tight strip etc. as stated in

the Drawings and Specification.

CF 1,281,589.00BF 1,281,589.00

Pool Houses (10nr) Cont'd

08 83 00 Mirrors

1 Supply and fix fixed mirror 900mm width x 1725mm high for nr 50 197.00 9,850.00

bathrooms (size, kind, quality, surface treatment, method of jointing,

etc. as per the Drawings and Specification).

09 00 00 - FINISHES

All works herein shall be completed in full compliance with the

schedule Drawings and Specification.

09 24 00 Cement Plastering

2 Plastering for walls to receive tiling at wet areas, width > 300mm, m2 11,794 21.00 247,674.00

(thickness, kind, quality, composition, mix materials, nature of base,

method of construction, layout and treatments, thermal insulation,

moisture resistant treatment, method of jointing, etc. as per the

Drawings and Specification).

External walls

3 Self coloured rendering (pre coloured mineral wall coating) for m2 1,064 29.00 30,856.00

external walls, width > 300mm, (thickness, kind, quality,

composition, mix materials, nature of base, method of construction,

layout and treatments, thermal insulation, moisture resistant

treatment, method of jointing, etc. as per the Drawings nr A0-A933

800mm high, finished, all accessories and hardware including but not

Page 1389: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

and Specification).

4 m2 640 55.00 35,200.00

only ≤ 15° from horizontal, fixed over cement sand screed (screed

treatments, method of jointing, etc. as per the Drawings and

Specification.

Wall tiling

5 White body wall tile (typeWT1) 325mm x 977mm size for toilets and m2 8,845 72.00 636,840.00

bathroom walls, width > 300mm, fixed over cement sand plaster,

White colour, thickness, method of construction, layout and

treatments, method of jointing, etc. as per the Drawings and

Specification.

Additional Items

6 The Contractor is to list here and price any items shown on the Drawings, mentioned in the

Specifications or required for the satisfactory completion of this section, but not mentioned

here. Any such items not listed below shall be deemed to be included. item

6.1 Mirrors with size 1500 x 1125mm nr 10 138.00 1,380.00

CF 2,243,389.00BF 2,243,389.00

Pool Houses (10nr) Cont'd

09 91 00 - Painting

Wall -Painting

1 Painting for walls, girth > 300mm, (kind, quality of materials, painted m2 2,948 11.00 32,428.00

on cement plastering, preparatory works, priming coat, undercoats,

finishing coat method of application, etc. as per the Drawings nr A0-

A821and Specification).

Ceiling -Painting

2 Painting (type PT1) for ceiling, girth > 300mm, (kind, quality of m2 640 11.00 7,040.00

materials, painted on cement plastering, preparatory works, priming

coat (1nr), undercoats (1nr), finishing coat (1nr), method of

application, etc. as per the Drawings nr A0-A821 and Specification).

Porcelain tile flooring (type - FT1), 600mm x 600mm, level or to falls

measured separately), thickness, method of construction, layout and

Page 1390: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

10 00 00 SPECIALTIES

10 28 00 –Toilet, Bath and Laundry Accessories

Supply & install Plumbing Fixtures as shown in Drawings and

Technical Specification including all accessories, fittings , flexible

connections etc.

3 Tissue paper holder (TPH) nr 50 21.00 1,050.00

4 Soap dispenser (SD) nr 50 35.00 1,750.00

5 Mixer tap W/shower head (MTFS) nr 40 171.00 6,840.00

6 Towel ring nr 40 35.00 1,400.00

7 Robe hook nr 90 17.00 1,530.00

22 00 00 - PLUMBING

All items hereunder to be described specified code of practice and

8 regulations, kind, quality, size, method of fixing , finishes or surface

treatments, etc. as per the Drawings and Specification).

8.01 Towel Pin nr 32 17.00 544.00

8.02 Towel Bar nr 32 31.00 992.00

CF 2,296,963.00BF 2,296,963.00

Pool Houses (10nr) Cont'd

22 05 23 General-Duty Valves for Plumbing Piping

Valves

Valves are classified according to type . Material and/or size . Rates

include furnishing and installing of valves, testing at manufacturer's

to pipe diameter which will be connected with it; as per Drawings

and Specification.

premises and on site; diameters of valves and water meter according

Page 1391: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Gate Valve

1 75 mm diam. nr 40 193.00 7,720.00

Angle Valve

2 20 mm diam. nr 180 0.00

3 25 mm diam. nr 50 0.00

Pressure Reducing Valve

4 75 mm diam. nr 10 1546.00 15,460.00

22 11 16 Domestic Water Piping

Domestic water piping is classified by material and diameter. Rates

include furnishing and installing of pipes, fittings, accessories, fixing

supports, joints, sleeves, special parts, connections, hanger

supports. Rates to include all works and materials necessary for

complete installation for piping system as per the Drawings and

Specification.

Water Supply System

1-Cold Water Supply

5 75 mm diameter. m 90 84.00 7,560.00

6 50 mm diameter. m 220 45.00 9,900.00

7 40 mm diameter. m 50 34.00 1,700.00

8 25 mm diameter. m 120 21.00 2,520.00

CF 2,341,823.00BF 2,341,823.00

Pool Houses (10nr) Cont'd

1 20 mm diameter. m 290 14.00 4,060.00

2-Hot Water Supply

Page 1392: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2 20mm diameter m 210 14.00 2,940.00

3 - Accessories

3 Water Hammer Arrestor m 20 45.00 900.00

4 Pressure Gauge m 20 46.00 920.00

5 Strainer 75 mm. m 10 193.00 1,930.00

22 13 16 Sanitary Waste and Vent Piping

Sanitary Pipe Works

Sanitary pipe works is classified by material and diameter. Rates

include furnishing and installing of pipes, fittings, accessories, fixing

manufacturer's premises is included. All as per the Drawings and

Specification.

Pipes and fitting above ground

Waste pipe

6 50 mm diameter. m 140 12.00 1,680.00

Pipes and fitting below ground

Waste pipe

7 75 mm diameter. m 50 29.00 1,450.00

8 110 mm diameter. m 140 38.00 5,320.00

Soil pipe

9 160 mm diameter. m 170 38.00 6,460.00

support, joints, sleeves , special parts, connections, hanger supports.

Rates for pipework below ground also include excavation, backfilling

, civil work, trenches and any other accessories or fittings necessary

for complete installation of the piping system. Testing of pipes at the

Page 1393: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 2,367,483.00BF 2,367,483.00

Pool Houses (10nr) Cont'd

Vent Pipe Works

Vent pipes are classified by material and diameter. Rates include

joints, sleeves, special parts, connections, hanger supports. Rates

include furnishing and installing of pipes, fittings, accessories, fixing

manufacturer's premises is included. All as per the Drawings and

Specification.

Pipes and fittings above ground

1 75 mm diameter. m 70 17.00 1,190.00

Pipes and fitting below ground

2 75 mm diameter. m 50 29.00 1,450.00

22 13 19.13 Sanitary Drains

pipework) are classified by material and diameter. Rates include

furnishing and installing of pipes, fittings, accessories, fixing

furnishing and installing of pipes, fittings, accessories, fixing support,

support, joints, sleeves , special parts, connections, hanger supports.

Rates for pipework below ground also include excavation, backfilling

, civil work, trenches and any other accessories or fittings necessary

for complete installation of the piping system. Testing of pipes at the

Sanitary drains (to include rainwater pipework and condensate drain

supports, joints, sleeves, special parts, connections, hanger supports.

Page 1394: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Rates also include testing of pipes at the manufacturer's premises.

All as per the Drawings and Specification.

Rain water Pipe

3 75 mm diameter. m 70 17.00 1,190.00

22 33 00 Electric Domestic Water Heaters

Electric domestic water heaters are classified according to capacity.

Rates include furnishing of heater complete with safety valves, air

set (angle, gate, non return, etc. .), thermostat, heating element,

contactors, switch, support, bolts, nuts, connection of pipes, testing

on site, commissioning and putting into service.

4 EWH-PTS-01 with (100 liters / 1500 W) capacity. nr 40 326.00 13,040.00

5 EWH-PTS-02 with (50 liters / 1200 W) capacity. nr 20 278.00 5,560.00

CF 2,389,913.00BF 2,389,913.00

Pool Houses (10nr) Cont'd

22 40 00 Plumbing Fixtures

All items described hereunder to be of kind, quality, size, nature of

base, method of fixing, complete with accessories etc. as per the

Drawings nr V1-903 and Specification

1 Floor Drain (FD) nr 110 193.00 21,230.00

2 Flexible Shower Hose (Sprayer , valves , etc….) nr 50 39.00 1,950.00

3 Floor mounted (Flush Valve) western water closet set (fitting, nr 50 417.00 20,850.00

push button, flush valve)

4 Floor clean out nr 20 204.00 4,080.00

5 Roof drain nr 20 173.00 3,460.00

vent, pressure and temperature relief gauges, drain valves, all valves

Page 1395: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

6 Vent cap nr 20 44.00 880.00

As per the drawing it is integrated

7 Lavatory nr 50 with the Acrylic Countertop

8 Shower (SHO) nr 4 923.00 3,692.00

9 Taps for Lavatory including fittings , plugs, valves, connections nr 50 169.00 8,450.00

and waste.

22 00 00 - Plumbing

Additional Items

10 Inspection chamber as per Drawings and Specification; nr 10 642.00 6,420.00

connected directly to sewer network.

11 Marking the position of holes, mortices and chases in the structure Item 1 0.00

12 Identification; plates, discs, lables, tapes, bands, arrows, symbols, Item 1 826.00 826.00

letters, numbers and charts; as stated on Drawings and in

13 Testing and commissioning of entire installation Item 1 8465.00 8,465.00

13.1 Urinal including (fitting, valve, cistern, constant flush valve, water and waste

connection, chrome spreader pipe) nr 6 461.00 2,766.00

CF 2,472,982.00BF 2,472,982.00

Pool Houses (10nr) Cont'd

Additional Items

1 Preparation of as-built Drawings Item 1 0.00

2 Preparation of operation and maintenance manuals Item 1 0.00

3 The Contractor is to list here and price any items shown on the Item 1 0.00

Drawings, mentioned in the Specifications or required for the

26 00 00 - ELECTRICAL

4 Supply and install complete Electrical works full incompliance with Item 1 181656.00 181,656.00

the Drawings and Specifications

Page 1396: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

23 00 00 - HEATING, VENTILATING, AND AIR

CONDITIONING (HVAC)

5 Item 1 0.00

Drawings and Specifications.

31 00 00 EARTHWORK

All works herein shall be completed in full compliance with the

Drawings and Specification

31 23 16 Excavation

6 Excavating top soil for preservation, average depth 150mm. m2 1,452 3.00 4,356.00

7 Excavating pits, maximum depth ≤0.50m. m3 653 8.00 5,224.00

31 23 23.13 Backfill

8 Filling to excavations, average thickness > 0.25 m, imported m3 363 12.00 4,356.00

hardcore, all fill shall be compacted to 75% relative density for

cohesion-less soils as per ASTM D4254/ASTM D4293 or 95%

maximum density as determined by ASTM D698 for cohesive

material, as per the Drawings and Specifications).

31 23 23.23 Compaction

9 Surface treatments, compacting bottom of excavation, compaction m2 1,452 3.00 4,356.00

to meet 85% of relative density for cohesion-less soils or 95%

maximum density as determined by ASTM D1557 for cohesive

materials per the Drawings and Specifications)

CF 2,672,930.00BF 2,672,930.00

Pool Houses (10nr) Cont'd

31 23 16.26 Rock Removal

1 m3 653 4.00 2,612.00

31 31 16 Termite Control

Supply and install complete HVAC system full incompliance with the

Disposal of excavated material, off site as stated in the Specification.

Page 1397: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2 Termite control for the horizontal surface (method and type of m2 1,452 1.00 1,452.00

treatment as per the Drawings and Specifications)

3 Termite control for vertical surface (method and type of treatment m2 171 1.00 171.00

as per the Drawings and Specifications)

Total for Pool Houses (10nr)

CARRIED TO SUMMARY US Dollar 2,677,165.00

04 00 00 Masonry 1,988,539.00

11 00 00 Equipment 1,414,774.00

12 00 00 Furnishings 4,524,161.00

13 00 00 Special Construction 672,645.00

32 00 00 Exterior Improvements 22,649,531.00

Pool Houses (10nr) 2,677,165.00

TOTAL FOR LANDSCAPING TO SUMMARY US Dollar 33,926,815.00

Page 1398: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

As per the drawing it is integrated

Page 1399: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Item Nr. Description Unit Qty Rate

Telecommunication / Low Current

Infrastructure - Civil Works

1 Distribution Duct, 12 x 50mm PVC m 10,015 174.00

2 Drop Duct, 2 x 32mm HDPE m 19,000 15.00

Excavate pits and backfill in accordance with Engineer's specification.

3 Small Man hole nr 2 2689.00

4 Hand Hole nr 84 1107.00

FTTH

Single Mode Fiber Optic Cable

5 Core specification to be verified on site by Engineer m 19,515 19.00

IP CCTV

6 Fixed Dome Type Camera - Ceiling Mounted (At Serviced Apartments) nr 22 included in service aprtment

7 IP PTZ Dome Camera - Pan 0 -360, Tilt 0-90 nr 2 6652.00

8 Panoramic Dome Type Color IP Camera nr 7 773.00

Excavate trenches to receive ductwork and cabling as per drawings; and backfill as per Engineer's Instruction; Supply, Install, Test, connect and commission inclusive of all cabling, conduits and containment, all in accordance with the relevant service provider regulations ,rules, recommendation and requirements and in accordance with the specifications and drawings.

Excavate trenches to receive ductwork and cabling as per drawings; and backfill as per Engineer's Instruction; Supply, Install, Test, connect and commission inclusive of all cabling, conduits and containment, all in accordance with the relevant service provider regulations ,rules, recommendation and requirements and in accordance with the specifications and drawings.

Supply, Install, Test, connect and commission inclusive of all cabling, conduits and containment, socket outlets, all in accordance with the relevant regulations , rules, recommendation and requirements and in accordance with the specifications and drawings.

Page 1400: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

9 IP Fixed Type, Outdoor Camera nr 24 1520.00

10 IP Fixed Type, Outdoor Camera (At Utility Buildings) nr 13 included in utility bldg

11 IP Fixed Type, Outdoor Camera (At Security Building) nr 1 included in security bldg

12 IP Fixed Type, Outdoor Camera nr 1 1520.00

13 IP Fixed Type, Outdoor Camera (At MVSG) nr 4 1520.00

14 nr 6 included in security bldg

15 nr 47 1041.00

16 32" LED Monitor nr 6 1245.00

17 Hand Hole nr 34 481.00

18 2 core Single Mode Fiber Optic Cable m 29,540 5.00

19 50mm HDPE pipe m 3,387 7.00

CF

BF

Fire Alarm System Network

1 Communication Cable m 24,320 6.00

2 Entry Box nr 519 481.00

3 Hand Hole nr see infrastructure - civil work

IP Fixed Type, High Resolution Outdoor Camera, Plate Number Reader, (At Security Building)

POE Media Converter (Installed Near the Camera) With 220V UPS Power Supply

Supply, install, connection, testing and commissioning of wiring and equipment for Fire Alarm System including all necessary materials and accessories to reflect complete system installation.

Page 1401: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

AMOUNT FOR SITEWORKS - TELECOMMUNICATIONS TO SUMMARY US Dollar

Page 1402: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Amount

1,742,610.00

285,000.00

5,378.00

92,988.00

370,785.00

included in service aprtment

13,304.00

5,411.00

Page 1403: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

36,480.00

included in utility bldg

included in security bldg

1,520.00

6,080.00

included in security bldg

48,927.00

7,470.00

16,354.00

147,700.00

23,709.00

2,803,716.00

2,803,716.00

145,920.00

249,639.00

see infrastructure - civil work

Page 1404: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3,199,275.00

Page 1405: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Item Nr. Description Unit Qty Rate Amount

DOMESTIC AND FIRE WATER - CHLORINATION BUILDING

03 00 00 - CONCRETE

03 11 13 Structural Cast-in Place Concrete Forming

1 m³ 2 188.00 376.00

03 31 00 Structural Concrete

2 m³ 5 504.00 2,520.00

3 m³ 3 838.00 2,514.00

4 m³ 5 780.00 3,900.00

5 m³ 7 372.00 2,604.00

6 m³ 1 748.00 748.00

7 m³ 9 645.00 5,805.00

8 m² 5 912.00 4,560.00

Notwithstanding the Provisions of the Standard Method of Measurement of Building Works Seventh Edition, 1988 (SMM7) the following,concrete works are measured m³/m including. reinforcement bars and formworks. The Contractor is to include for cost of reinforcement and formwork with concrete works. No additional charge or cost for reinforcement and formwork separately will be entertained due to lack or want of knowledge.

All concrete works herein shall be completed in full compliance with the Drawings nr UI CB - S101 and Specification.

Plain Concrete, 20 Mpa for blinding Beds, Thickness ≤ 150mm. Poured againts the compacted soil, as the Structural Notes and Specification.

Reinforced concrete 35 Mpa, foundations ( footings): kind,quality, curing details etc. as stated in the Structural Notes and Specification.

Reinforced concrete 35 Mpa for ground beams; kind,quality, curing details etc. as stated in the Structural Notes and Specification.as stated in the Structural Notes and Specification.

Reinfoced concrete beds 35 Mpa for slab with A393 welded wire mesh, on grade; thickness ≤ 150mm, poured againts the compacted soil kind quality, curing details etc.as stated in the Structural Notes and Specification.

Reinforced concrete for substructure columns35 Mpa up to slab on grade; kind quality, curing details etc.as stated in the Structural Notes and Specification.as stated in the Structural Notes and Specification.

Reinforced concrete 35 Mpa in first floor and roof level, 250mm thk, slab as stated in the Structural Notes and Specification.

Reinforced concrete 35 Mpa for super structure slabs, thickness 250mm, (kind,quality, curing details etc. as stated in the Structural Notes and Specification.

Reinforced concrete 35 Mpa for super structure beams. (kind,quality, curing details etc. as stated in the Structural Notes and Specification.

Page 1406: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 23,027.00

BF 23,027.00

CONCRETE (Cont'd)

1 m³ 3 1260.00 3,780.00

2 m³ 3 358.00 1,074.00

03 53 00 Concrete Topping

3 250mm wide x 200mm high reinforced concrete 35 Mpa for lintel. m 35 27.00 945.00

4 m 42 17.00 714.00

5 m 60 37.00 2,220.00

Additional Items

Reinforced concrete 35 Mpa for superstructure columns, (kind quality, curing details etc. as stated in the Structural Notes and Specification.

Reinforced concrete 35 Mpa for steps, (kind,quality, curing details etc. as stated in the Structural Notes and Specification.

Sand cement/concrete screed for floors, width > 300mm, (thickness,kind quality,composition mix, nature of base method of construction. Layout and treatments,thermal insulation,moisture resistant treatment method of jointing, etc, as per the Drawings and S

Sand cement/concrete screed for roof with A 252 mesh, width > 300mm, (thickness,kind quality,composition mix, nature of base method of construction. Layout and treatments,thermal insulation,moisture resistant treatment method of jointing, etc, as per the Drawings and Specification.

Page 1407: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

6

CF 31,760.00

BF 31,760.00

04 00 00 - Masonry

04 22 00 - Concrete Unit Masonry

Internal walls and Partitions

1 m² 59 37.00 2,183.00

External walls

2 m² 116 42.00 4,872.00

04 00 00 - Masonry

Additional Items

3

05 00 00 METALS

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included

All Masonry works herein shall be completed full incompliance with the Drawings nr UB-CB-A204, UB-CB-A704, UB-CB-A802 and Specification.

150mm thick CMU wall, internal vertical block work (kind, quality and size of blocks,; type of bond, mix of motar etc. to be included as per the Specification).

250mm thick CMU wall, external, vertical block work, (kind, quality and size of blocks,; type of bond, mix of motar etc. to be included as per the Specification).

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section,but not mentioned here.Any such items not listed below shall be deemed to be included.

All metals works herein shall be completed in full compliance with the Drawings UB-CB- A204, A504, A704, A802 and Specification.

Page 1408: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

05 70 00 - Decorative Metal

4 nr 1 1010.00 1,010.00

5 nr 1 1897.00 1,897.00

6 Ditto 3850mm lenght nr 1 2530.00 2,530.00

7 Ditto 1600mm lenght nr 1 1247.00 1,247.00

CF 45,499.00

BF 45,499.00

05 00 00 Metals

Additional Items

1

CF 45,499.00

BF 45,499.00

06 00 00 WOOD, PLASTIC, AND COMPOSITES

1 nr 1 485.00 485.00

06 00 00 Wood, Plastic, and Composites

Additional Items

2

Supply and fix Galvanized steel ladder 6400 mm high 475 width with safety cage including mechanical as per Drawings and as per Specification.

Supply and fix floor drain including steel grating 2975 mm leght 500 mm with support, accessories as per Drawings and as per Specification.

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section,but not mentioned here.Any such items not listed below shall be deemed to be included.

Supply and fix solid acrylic counter top shaped 1300mm long 533mm wide oval shape with opening for single wash basin as shown in the Drawing nr UB-CB-A204 and Specification.

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Page 1409: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 45,984.00

BF 45,984.00

07 00 00 THERMAL AND MOISTURE PROTECTION

07 10 00 Damp proofing and Waterproofing

Substructure Waterproofing

1 m² 37 5.00 185.00

2 m² 74 2.00 148.00

3 m² 33 5.00 165.00

Wet Area Waterproofing / Roof Waterproofing

4 m² 9 22.00 198.00

5 m² 3 22.00 66.00

6 m² 60 39.00 2,340.00

7 m² 60 23.00 1,380.00

All works herein shall be completed in full compliance with the Drawings nr UB-CB-S101, UB-CB-A204, UB-CB-A504, UB-CB-A704, UB-CB-A802 and Specification.

Waterproofing works for substructure with two coast of bitumen paint, vertical surface, width > 300mm (kind, quality, method of application, thickness as per the Drawings and Specification)

Waterproofing works for substructure with vapour barrier 250 microns, horizontal surface, width > 300mm (kind, quality, method of application, thickness as per the Drawings and Specification)

Waterproofing works for substructure with two coast of bitumen paint, vertical surface, width > 300mm (kind, quality, method of application, thickness as per the Drawings and Specification)

All works herein shall be completed in full compliance with the Drawings nr UB-CB-S101, UB-CB-A204, UB-CB-A504, UB-CB-A704, UB-CB-A802 and Specification.

Waterproofing works for wet area, vertical surface, width > 300mm 1200mm high (kind, quality, method of application, thickness as per the Drawings and Specification)

Waterproofing works for wet area, horizontal surface, width > 300mm 1200mm high (kind, quality, method of application, thickness as per the Drawings and Specification)

Waterproofing membrane with geotextile layer on top for roof, horizontal surface, width > 300mm (kind, quality, method of application, thickness as per the Drawings and Specification)

100mm thick rigid insulation for water proofing works at roof horizontal surface, width > 300mm (kind, quality, method of application, thickness as per the Drawings and Specification)

Page 1410: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 50,466.00

BF 50,466.00

07 00 00 Thermal and Moisture Protection

Additional Items

3

CF 50,466.00

BF 50,466.00

08 00 00 OPENINGS

08 14 00 - Wood Doors

1 nr 3 1227.00 3,681.00

2 nr 2 2234.00 4,468.00

08 51 13 Aluminum Windows

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

All works herein shall be completed in full compliance with the Drawings nr UB-CB-A204, UB-CB-A504, UB-CB-A704, UB-CB-A802 and Specification.

Notwithstanding the Provisions of the Standard Method of Measurement, doors, frames, vision panels, decoration and ironmongery have been measured as a composite item and The Contractor should make due reference to the drawings and specification. No claim for lack or want of knoledge will be entertained.

Supply and fix steel door, 900mm wide x 2200mm high with louver including HM steel frame type d1,including paint, all accessories and hardware including but not limited to hinges HDH type, SST outside door lock with adjustable hydraulic closing back check and latching control, lever handles and latch, wall stop with roses and escutheon as stated in the Drawings and Specification.

Supply and fix steel door, 00mm wide x 2200mm high with louver including HM steel frame type d1,including paint, all accessories and hardware including but not limited to hinges HDH type, SST outside door lock with adjustable hydraulic closing back check and latching control, lever handles and latch, wall stop with roses and escutheon as stated in the Drawings and Specification.

Page 1411: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3 nr 1 271.00 271.00

4 nr 4 651.00 2,604.00

5 nr 1 488.00 488.00

CF 61,978.00

BF 61,978.00

Aluminum Windows (Cont'd)

1 nr 4 271.00 1,084.00

08 83 00 Mirrors

2 nr 1 91.00 91.00

08 00 00 Openings

Additional Items

3

As per Question and Answer question No (267)

Doors

3.01 nr 2 949.00 1,898.00

CF 65,051.00

BF 65,051.00

09 00 00 - FINISHES

Supply and fix aluminum 12mm thck clear tempered glass window 600mm wide 1000mm high, with fixed panel including frame, type W1 finished powder coated, all accessories. and hardware including but not limited to hinges handle, lock, weather tight strip etc; as stated in the Drawings and Specification.

Supply and fix aluminum window 1000mm wide x 1000mm high, with fixed louver including frame, type W2 finished powder coated, all accessories. and hardware including but not limited to hinges handle, lock, weather tight strip etc; as stated in the Drawings and Specification.

Supply and fix aluminum window 1800mm wide x 1000mm high, with fixed louver including frame, type W3 finished powder coated, all accessories. and hardware including but not limited to hinges handle, lock, weather tight strip etc; as stated in the Drawings and Specification.

Supply and fix aluminum windo, 1000mm wide x 600mm high, with fixed louver including frame, type W4 finished powder coated, all accessories. and hardware including but not limited to hinges handle, lock, weather tight strip etc; as stated in the Drawings and Specification.

Supply and fix fixed mirror 600mm width x 900mm high ( size, kind, quality, surface treatment, method of jointing, etc; as per the Drawings and Specification).

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Folded doors at Shower and Eye Wash including frame and accessories

Page 1412: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

09 24 00 Cement Plastering

1 m² 206 22.00 4,532.00

2 m² 41 11.00 451.00

External Walls

3 m² 163 29.00 4,727.00

4 m² 44 29.00 1,276.00

CF 76,037.00

BF 76,037.00

09 30 13 Ceramic Tiling

Floor Tilling

1 m² 4 31.00 124.00

All works herein shall be completed in full compliance with the Drawings nr UB-CB-A204, UB-CB-A504, UB-CB-A704, UB-CB-A802 and Specification.

Plastering for walls to receive paint finish, width > 300mm, (thickness, kind quality, composition, mix materials, nature of base, method of construction layout and treatment, thermal insulation, moisture resistant treatment, method of jointing and jointing, etc; as per the Drawings UB-CB-A204, UB-CB-A504, UB-CB-A704, UB-CB-A802 and Specification.

Plastering for walls in stair areas, width > 300mm, (thickness, kind quality, composition, mix materials, nature of base, method of construction layout and treatment, thermal insulation, moisture resistant treatment, method of jointing and etc; as per the Drawings UB-CB-A204, UB-CB-A504, UB-CB-A704, UB-CB-A802 and Specification.

Self coloured rendering ( pre coloured mineral wall coating ) for external walls at second floor, roof and water tank area, width > 300mm, (thickness, kind quality, composition, mix materials, nature of base, method of construction layout and treatment, thermal insulation, moisture resistant treatment, method of jointing and etc; as per the Drawings UB-CB-A204, UB-CB-A504, UB-CB-A704, UB-CB-A802 and Specification.

Self coloured rendering ( pre coloured mineral wall coating ) for parapet, walls at roof area, width > 300mm, (thickness, kind quality, composition, mix materials, nature of base, method of construction layout and treatment, thermal insulation, moisture resistant treatment, method of jointing and etc; as per the Drawings UB-CB-A204, UB-CB-A504, UB-CB-A704, UB-CB-A802 and Specification.

Unglazed ceramic tile flooring at eye wash and shower, level or to falls onlys only ≤ 15 * from horizontal, fixed over cement sand screed ( screed measured separately). thickness, method of construction, layout and treatments, method of jointing and etc; as per the Drawings UB-CB-A204, UB-CB-A504, UB-CB-A704, UB-CB-A802 and Specification.

Page 1413: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2 m² 38 44.00 1,672.00

Wall Tiling

3 m² 41 37.00 1,517.00

09 50 00 Ceilings

Ceiling - Painting

4 m² 41 11.00 451.00

5 m² 206 11.00 2,266.00

CF 82,067.00

BF 82,067.00

09 00 00 - FINISHES

Additional Items

1

CF 82,067.00

BF 82,067.00

10 00 00 SPECIALTIES

10 28 00 - Toilet,Bath and Laundry Accessories

1 Paper towel dispenser (PTD) nr 1 30.00 30.00

Slip resistant epoxy flooring, level or to falls only ≤ 15 * from horizontal, fixed over cement sand screed ( screed measured separately). thickness, method of construction, layout and treatments, method of jointing and etc; as per the Drawings UB-CB-A204, UB-CB-A504, UB-CB-A704, UB-CB-A802 and Specification.

Glazed ceramic tile for walls. Width > 300mm, (kind, quality of materials, nature of base, preparatory works, priming coat ( 1nr ), undercoats, finishing coat (1nr) method of application etc; as per the Drawings UB-CB-A204, UB-CB-A802 and Specification.

Emulsion painting on exposed for ceiling, girth > 300mm, fixed over cement sand plaster, thickness, method of construction, layout and treatments, method of jointing and etc; as per the Drawings UB-CB-A204, UB-CB-A802 and Specification.

Painting for walls, girth > 300mm, (kind, quality of materials, painted on cement plastering, preparatory works, priming coat , undercoats, finishing coat method of application etc; as per the Drawings UB-CB-A204, UB-CB-A802 and Specification.

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Supply & install Plumbing Fixtures as shown in Drawing nr UB-CB-A204, UB-CB-A504, UB-CB-A704, UB-CB-A802 and Specification.

Page 1414: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2 Soap dispenser (SD) nr 1 22.00 22.00

3 Towel ring nr 1 35.00 35.00

4 Robe hook nr 1 17.00 17.00

5 Towel bar nr 1 31.00 31.00

6 Hand dryer nr 1 1155.00 1,155.00

10 44 13.13 Portable Fire Extinguishers

7 nr 1 54.00 54.00

10 00 00 SPECIALTIES

Additional Items

8

CF 83,411.00

BF 83,411.00

11 00 00 EQUIPMENT

11 00 00 Residential Equipment

Additional Items

1

All Items hereunder to be described with kind, quality, size, method of fixing,etc, as per the Drawings nr UB-CB-M201 and Specification.

Supply & install Portable Fire Extiguesher (5 kg multipurpose dry chemical)

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

All Items hereunder to be described with information such as appropriate to the procurement , design supply, execution, type, kind quality, size method of fixing, specified codes of practice,etc, as per the Drawings and Specification)

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Page 1415: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836
Page 1416: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 83,411.00

BF 83,411.00

12 00 00 FIRE SUPPRESSION

Additional Items

1

Fire Protection Pipe Works

2 m 2 Included in Item-5 below

3 m 2 Included in Item-5 below

21 13 00 FIRE SUPPRESSION SPRINKLE SYSTEM

4 Supply & install NOVEC 1230 nozzle nr 1 Included in Item-5 below

5 Supply & install 22 kg NOVEC 1230 cylinder nr 1 26674.00 26,674.00

CF 110,085.00

BF 110,085.00

22 00 00 - PLUMBING

All Items hereunder to be described specified codes of practice and regulations kind quality, size, method of fixing, finisher or surface treatments ,etc, as per the Drawings nr UB-CB-M201 and Specification)

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Fire main pipes, 50mm dia straight, (Type, nominal size, method of jointing, spacing and method of fixing supports, etc; as per the Drawings and Specification.

Fire main pipes, 40mm dia straight, (Type, nominal size, method of jointing, spacing and method of fixing supports, etc; as per the Drawings and Specification.

All Items hereunder to be described specified code of practice and regulation, kind quality, size method of fixing, finishes or surface treatments etc,as per the Drawings nr UB-CB-M201 and Specification)

Page 1417: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

22 05 23 General-Duty Valves for Plumbing Piping

1 Pressure reducing valve assembly nr 1 337.00 337.00

22 11 16 DOMESTIC WATER PIPING

2 m 10 12.00 120.00

3 m 5 19.00 95.00

22 13 16 Sanitary Waste and Vent Piping

Sanitary Pipe Works

4 m 5 29.00 145.00

5 m 12 17.00 204.00

6 m 9 17.00 153.00

7 m 3 12.00 36.00

Condensate Drain Pipe Works

8 m 12 9.00 108.00

CF 111,283.00

BF 111,283.00

22 33 00 Electric Domestic Water Heaters

Cold water supply pipes 25 mm diameter, straight, (Type, nominal size, method of jointing, spacing and method of fixing supports, etc; as per the Drawings and Specification.

Hot water supply 25 mm diameter, straight, (Type, nominal size, method of jointing, spacing and method of fixing supports, etc; as per the Drawings and Specification.

Waste water pipes 110 mm diameter, straight, (Type, nominal size, method of jointing, spacing and method of fixing supports, etc; as per the Drawings and Specification.

Waste water pipes 75 mm diameter, straight, (Type, nominal size, method of jointing, spacing and method of fixing supports, etc; as per the Drawings and Specification.

Waste water pipes 75 mm diameter, for roof drain straight, (Type, nominal size, method of jointing, spacing and method of fixing supports, etc; as per the Drawings and Specification.

Waste water pipes 50 mm diameter, straight, (Type, nominal size, method of jointing, spacing and method of fixing supports, etc; as per the Drawings and Specification.

Condensate drain pipes 20 mm diameter, straight, (Type, nominal size, method of jointing, spacing and method of fixing supports, etc; as per the Drawings and Specification.

Page 1418: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1 nr 1 326.00 326.00

22 40 00 Plumbing Fixtures

2 Floor Drain (FD) 75mm nr 3 345.00 1,035.00

3 Floor drain (FD) 50mm nr 2 172.00 344.00

4 Floor clean out 50mm nr 1 204.00 204.00

5 Roof drain nr 2 173.00 346.00

6 Wash basin ( WB ) oval shape nr 1 705.00 705.00

22 00 00 - Plumbing

Additional Items

7

23 07 13 Duct Insulations

8 m² 2 52.00 104.00

CF 114,347.00

BF 114,347.00

23 31 00 HVAC Ducts and Casting

Supply and install electric water heaters 100L/S, 1500W. 220/1/60 item to be described with information such as appropriate to the procurement, design supply execution, type, kind, quality, size method of fixing, specified codes of practice, etc; as per the Equipment schedule, Drawings nr UB-CB-M201 and Specification.

All Items described hereunder to be of kind, quality,, size, nature of base, method of fixing, etc,as per the Drawings nr UB-CB-M201 and Specification.

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

23 00 00 - HEATING, VENTILATING, AND AIR CONDITONING (HVAC)

All HVAC works shall be completed as per the Drawings and Specification

All Items hereunder to be described with in type, kind quality, thickness,method of fixing, specified codes of practice,etc, as per the Drawings and Specification)

Ductwork insulation including fixing accessories as per the Drawings nr UB-PA-M201, 202 and Specification.

Page 1419: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1 Exhaust air duct m² 2 66.00 132.00

23 34 00 HVAC FANS

2 Exhaust Fan: 355 L/S, 0.5 kw, 220 /1 /60 in-line cabinet centrifugal nr 1 1451.00 1,451.00

3 Exhaust Fan: 185 L/S, 0.25 kw, 220 /1 /60 wall mounted nr 1 516.00 516.00

4 Exhaust Fan: 70 L/S, 0.10 kw, 220 /1 /60 wall mounted nr 1 504.00 504.00

5 Exhaust Fan: 30 L/S, 0.30 kw, 220 /1 /60 wall mounted nr 1 504.00 504.00

23 37 00 Air outlets and inlets

6 Exhaust air grille 500mm x 300mm nr 1 47.00 47.00

7 Exhaust air louver 600mm x 300mm nr 1 57.00 57.00

CF 117,558.00

BF 117,558.00

23 82 00 Convection Heating and Cooling Units

23 33 13.13 Volume-Control Dampers

1 nr 1 1191.00 1,191.00

2 nr 1 1191.00 1,191.00

All Items hereunder to be described with in type, kind quality, thickness,method of fixing, specified codes of practice,etc, as per the Drawings nr UB-CB-M201 and Specification)

All items hereunder to be described with, information such as appropriate to the procurement capacity, design, supply, execution, type kind,quality,size, method of fixing,specified codes of practice,etc,as per the Drawings and Specification

All Items hereunder to be described with information such as type, kind quality, thickness,method of fixing, specified codes of practice,etc, as per the Drawings and Specification)

All items hereunder to be described with, information such as appropriate to the procurement capacity, design, supply, execution, type kind,quality,size, method of fixing,specified codes of practice,etc,as per the Drawings nr UB-CB-M201 and Specification

Supply and install FCU/ACCU: 185 L/S, 2.8 kw, total load 1.8 sensible load 1.8, supply power 220/1/60 Hi-wall deco split.

Supply and install FCU/ACCU: 200 L/S, 2.8 kw, total load 2.0 sensible load 2.0, supply power 220/1/60 Hi-wall deco split.

Page 1420: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3 nr 1 1191.00 1,191.00

4 nr 1 1191.00 1,191.00

5 Air balancing of the ducting network Item 1 INCLUDED

6 Testing balancing and commissioning of all the equipments Item 1 496.00 496.00

Additional Items

7

CF 122,818.00

BF 122,818.00

26 00 00 - ELECTRICAL

26 05 19 Low Voltage Electrical Power Conductors and Cables

1 Lighting circuits Item 1 863.00 863.00

2 Power circuits Item 1 501.00 501.00

Supply and install FCU/ACCU: 150 L/S, 2.8 kw, total load 1.5 sensible load 1.5, supply power 220/1/60 Hi-wall deco split.

Supply and install FCU/ACCU: 145 L/S, 2.8 kw, total load 1.6 sensible load 1.4, supply power 220/1/60 Hi-wall deco split.

All Items hereunder to be deUS Dollaribed with type of installation preparatory operations, stages of test required attendance applicable codes etc, as per the Drawings and Specification)

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

All works hereunder shall be completed as per the Drawings and Specification.

All Items hereunder to be described with information such as type, kind number of cores, armoring and sheathing, method of fixing, specified codes of practice, etc. as per the Drawings and Specification.

Notwithstanding the provision of the method of measurement, cables have been itemised and referenced to the circuit, the contractor is to make due reference to drawings nrs UB-GE-EL020, GE-EL040-00, EL050-00, UB-GE-EL051-01, EL051-02, EL05-03,UB-CB-EL101-00,UB-CB-EL201-00, EL301-00, EL-701-00, for full details and is to allow for all cabling juctions, flexible connections, feeder units etc; required to complete the installation in accordance with the drawings and Specification, No claim for want or lack of knoledge will be entertained.

Page 1421: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3 Pumps circuits Item 1 247.00 247.00

4 Water heaters circuits Item 1 83.00 83.00

5 Fan circuits Item 1 148.00 148.00

6 HVAC control circuits Item 1 416.00 416.00

7 Lightning protection Item 1 4836.00 4,836.00

26 05 26 Grounding and Bonding for Electrical System

8 Grounding system Item 1 3793.00 3,793.00

CF 133,705.00

BF 133,705.00

26 41 13.13 Lightning Protection for Buildings

1 Lightning system Item 1 1136.00 1,136.00

26 05 33.13 Conduit for Electrical System

2 Item 1 1608.00 1,608.00

26 24 13 Switchboards

3

4 Programmable logic control (PLC) nr 1included in mech equipment

26 24 16 Panel Boards

5 Lightning and power panel ( LPP-CB ) nr 1 1294.00 1,294.00

26 27 13 Electricity Metering

All Items hereunder to be described with information such as type, kind, method of fixing,specified codes of practice ,etc, as per the Drawings and Specification)

Cables and conduits in final circuits, cable installation, size type and description of final circuits(sockets, switch etc;)

All Items hereunder to be described with information such as type, kind rated capacity,method of fixing,cores reference to Specification, fuses, background specified codes of practice ,etc, as per the Drawings and Specification)

All Items hereunder to be described with information such as type, kind, rated capacity, method of fixing,cores reference to Specification, fuses, background, specified codes of practice ,etc, as per the Drawings and Specification)

Page 1422: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

6

CF 137,743.00

BF 137,743.00

26 27 26 Wiring Devices

Switches & Push Buttons

1 One way one gang switch 15A nr 3 10.00 30.00

2 One way two gang switch 15A nr 2 12.00 24.00

Power Outlets

3 Duplex receptacle outlet, 230V, 20A normal power supply nr 9 19.00 171.00

4Duplex receptacle outlet, 230V, 20A power supply with waterproof

nr 1 58.00 58.00

5 nr 3 19.00 57.00

6 nr 1 212.00 212.00

7 nr 1 16.00 16.00

8 Non-fusible disconnect switch, single pole NEMA 4x nr 8 697.00 5,576.00

26 28 16.13 Enclosed Circuit Breakers

9 Supply, install, test, and commission circuit breaker 100A nr 1 0.00 0.00

All Items hereunder to be described with information such as type, kind, rated capacity, method of fixing,cores reference to Specification, fuses, background, specified codes of practice ,etc, as per the Drawings and Specification)

All Items hereunder to be described with information such as appropriate to the procurement , type, kind quality, size method of fixing, specified codes of practice,etc, as per the Drawings and Specification)

Duplex receptacle outlet, 230V, 20A connectedto emergency power supply

Duplex receptacle outlet, 230V, 20A floor box, connectedto emergency power supply

Water heater receptacle outlet, 230V, 20A normal emergency power supply with fuse

All Items hereunder to be described with information such as appropriate to the procurement , type, kind quality, size method of fixing, specified codes of practice,etc, as per the Drawings and Specification)

Page 1423: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 143,887.00

BF 143,887.00

26 50 00 Lighting

1 nr 10 330.00 3,300.00

2 Down light luminaire, mounting 1 x 26W CFL nr 3 206.00 618.00

3 nr 9 410.00 3,690.00

Chlorine Dosing Pumps

4 nr 2 82581.00 165,162.00

5 item 1 2065.00 2,065.00

Additional Items

6

All Items hereunder to be described with information such as appropriate to the procurement ,capacity design supply, execution, type, kind quality, size method of fixing, specified codes of practice,etc, as per the Drawings and Specification)

Pendant mounted with a suspended rod highbay, heavy duty, indoor industrial luminaire with metal halide elliptical 250w/220w/60hz lamps, electronic ballast, symmentrical aluminum reflector & glass protection of ip-65 (C2 type )

Wall mounted bulkhead outdoor landscape clear with a 100w/220w/60hz mercury vapour elliptical lamp, prismatic pattern moulded polycarbonate; diffuser cover of ip-65 (BH1 type )

Supply install, test and commission horizontal chlorine pumps (1 duty + 1 standby). 2 L/S flow, 10m head, 1 kw for dosing system at chlorination room for operational and functional installation as per the drawing, equipment schedule and Specification.

Supply, installation, testing, commissioning, adjusting, balancing and guarantee including operation, maintenance, tools & spare parts, all mechanical fittings including but not limited to piping works at the chlorination room, valves, tees, flarges, elbows, joints, air vent pipes, pressure gauges, pressure switches, balancing valves, flexible connections, rubber isolators, concrete bases, control panel, electrical connections, fitting, and all necessary to complete the work as per the drawings and specification and Engineer's instructions.

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Page 1424: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 318,722.00

BF 318,722.00

27 00 00 COMMUNICATIONS

Telecommunication / Low Current

STRUCTURED CABLING SYSTEM

Item 1 6219.00 6,219.00

27 21 29 Data Communications switches and Hubs

27 21 33 Data Communications Wireless Access Points

1 Information Outlet, Flush Type 1 DATA 1 Telephone nr 4 48.00 192.00

2 IP fixed type CCTV, wall mounted outdoor camera (weather proof ) nr 2 1520.00 3,040.00

3 Card reader, smart card nr 4 235.00 940.00

4 Electromagnetic door latch nr 4 383.00 1,532.00

5 Magnetic door contact switch nr 4 222.00 888.00

All Items hereunder to be described with information such as appropriate to the procurement ,type, kind quality, size method of fixing, specified codes of practice,etc, as per the Drawings nr UB-CB-T201, UB-CB-T301 and Specification)

Supply , Install Test, connect and commission inclusive of all cabling, conduits and containment, socket outlets, all in accordance with the relevant service provider regulations, rules, recommendation and requirements and in accordance with the specification and drawings.

Page 1425: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

6 Request to exit button nr 4 309.00 1,236.00

7 Pull box nr 1 included in the above

27 00 00 Communications

Additional Items

8

ADDITIONAL

8.1 Control Panel for Access Control nr 1 1779.00 1,779.00

CF 334,548.00

BF 334,548.00

28 00 00 ELECTRONIC SAFETY AND SECURITY

28 31 00 Fire Detection and Alarm

1 Supply, install smoke detector nr 4 110.00 440.00

2 Supply, install heat detector nr 2 104.00 208.00

3 Manual pull station - 1.2 meters from FFL to the centre of the device. nr 3 110.00 330.00

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

All Items hereunder to be described with information such as appropriate to the procurement ,type, kind quality, size method of fixing, specified codes of practice,etc, as per the Drawings and Specification)

Page 1426: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

4 nr 1 123.00 123.00

5 Fault insulator - ceiling mounted or as per site situation. nr 1 110.00 110.00

6 nr 1 110.00 110.00

28 00 00 Electronic Safety and Security

7

CF 335,869.00

BF 335,869.00

31 00 00 EARTHWORK

31 10 00 Site Clearing

1 Site preparation, clearing site vegetation 50 2.00 100.00

31 23 16 Excavation

2 Excavation top soil for preservation, average depth 150mm m³ 50 3.00 150.00

3 Excavating pits, depth of excavation not exceeding 2 m m³ 21 8.00 168.00

31 23 16 Backfill

4 m³ 14 12.00 168.00

31 23 23.23 Compaction

Sounder/fire alarm bell/horn - 0.30 meters below from ceiling line to the centre of the device.

Control module - 0.20 meters below from ceiling line to the centre ot the device

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

All works herein shall be comnpleted in full compliance with the Drawings nr UB-CB-S101 and Specification.

m3

Filling to excavation, average thickness > 0.25 m, arising from excavated materials, all fill shall be compacted to 75% relative density for cohesion-less soils as per ASTM D4254/ASTM D4293 or 95% maximum density as determined by ASTM D698 for cohesive material, as per the Drawings and sPECIFICATION.

Page 1427: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

5 m² 20 3.00 60.00

31 23 23.23 Rock Removal

6 Disposal of excavated material, off site as stated in the Specification. nr 7 4.00 28.00

31 31 16 Termite Control

7 m² 15 1.00 15.00

8 m³ 17 0.00 0.00

CF 336,558.00

BF 336,558.00

Additional Items

1

Surface treatment, compacting bottom of excavation, compaction to meet 85% of relative density for cohesion-less or 95% maximum density as determined by ASTM D1557 for cohesive materials per the Drawings and Specification).

Termite control for the horizontal surface ( method and type of treatment as per the Drawings and Specification.

Termite control for the vertical surface ( method and type of treatment and as per the Drawings and Specification.

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Page 1428: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CARRIED TO SUMMARY US Dollar 336,558.00

DOMESTIC AND FIRE WATER - WATER TANK

Total for DOMESTIC AND FIRE WATER - CHLORINATION BUILDING

Page 1429: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

03 00 00 - CONCRETE

03 11 13 Structural Cast-in-Place Concrete Forming

1 m³ 257 188.00 48,316.00

2 Ditto bypasses m³ 10 188.00 1,880.00

3 Ditto Inlet m³ 2 188.00 376.00

4 Ditto manholes m³ 1 188.00 188.00

03 31 00 Structural Concrete

5 m³ 1767 534.00 943,578.00

6 Ditto bypasses; 300 mm thick m³ 21 479.00 10,059.00

7 Ditto Inlet; 300 mm thick m³ 7 529.00 3,703.00

8 Ditto manholes; 300 mm thick m³ 3 609.00 1,827.00

9 m³ 1515 542.00 821,130.00

10 Ditto bypasses; 250 mm thick m³ 38 772.00 29,336.00

11 Ditto Inlet; 250 mm thick m³ 11 770.00 8,470.00

12 Ditto manholes; 250 mm thick m³ 13 841.00 10,933.00

Notwithstanding the Provisions of the Standard Method of Measurement, doors, frames, vision panels, decoration and ironmongery have been measured as a composite item and The Contractor should make due reference to the drawings and specification. No claim for lack or want of knoledge will be entertained.

All concrete works herein shall be completed in full compliance with the Drawings nr UB-CB-WT- S101, UB-WT-S201, UB-WT-S401, UB-WT-S402, UB-WT-S403, UB-WT-S404, UB-WT-S405 and Specification.

Plain concrete 20 Mpa, for blinding Beds, thickness ≤ 150mm, poured againts the compacted soil, as in the Structural Notes and Specification.

Reinforce concrete 35 Mpa, raft foundation for water tank, 700mm thick including sump pit (kind, quality, curing details etc; as stated in the Structural Notes and Specification.

Reinforce concrete 35 Mpa, substructure; 700mm thick; kind, quality, curing details etc; as stated in the Structural Notes and Specification.

Page 1430: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 1,879,796.00

BF 1,879,796.00

Concrete ( Cont'd )

1 m³ 7 746.00 5,222.00

2 Ditto bypasses; m³ 2 718.00 1,436.00

3 m³ 13 947.00 12,311.00

4 m³ 680 572.00 388,960.00

5 Ditto manholes; 300 mm thick m³ 4 519.00 2,076.00

6 Ditto bypasses; 250 mm thick m³ 17 572.00 9,724.00

03 41 00 Precast Structural Concrete

7

8 1600 mm x 3650 mm nr 2 787.00 1,574.00

9 790 mm x 3650 mm nr 1 389.00 389.00

Reinforce concrete 35 Mpa, substructure; 700mm thick; kind, quality, curing details etc; as stated in the Structural Notes and Specification.

Reinforce concrete 35 Mpa, tank cover slab thickness 300mm ( kind, quality, curing details etc; as stated in the Structural Notes and Specification.

Reinforce concrete 35 Mpa, tank cover slab thickness 300mm ( kind, quality, curing details etc; as stated in the Structural Notes and Specification.

Supply and fix removable multi span cover (Gatic or equalvalent) and frame 200 mm thick at reservoir inlet chamber.

Page 1431: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

10 790 mm x 2800 mm nr 1 299.00 299.00

11 nr 1 87.00 87.00

03 37 13 Shot Crete/ masonry wall

12 Shot Crete for substructure under ground tank wall m² 808 47.00 37,976.00

(200mm thick Block CMU as per Dwg No. UB-WT-S401)

CF 2,339,850.00

BF 2,339,850.00

Concrete ( Cont'd )

03 53 00 Concrete Topping

Supply and fix access cover and frame 800 mm x 800 mm at reservoir inlet chamber.

Page 1432: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1 m² 2570 17.00 43,690.00

2 Ditto bypasses m² 97 17.00 1,649.00

3 Ditto Inlet m² 25 17.00 425.00

4 Ditto manholes m² 12 17.00 204.00

03 00 00 - CONCRETE

Additional Items

5

Sand cement/concrete screed for floors, width > 300mm, (thickness,kind quality,composition mix, nature of base method of construction. Layout and treatments,thermal insulation,moisture resistant treatment method of jointing, etc, as per the Drawings and Specification).

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Page 1433: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 2,385,818.00

BF 2,385,818.00

05 00 00 METALS

05 70 00 Decorative Metal

1 nr 6 2455.00 14,730.00

2 nr 6 2484.00 14,904.00

As per Question and Answer No (533) include in scope3 nr 2 483.00 966.00

4 nr 2 904.00 1,808.00

nr 1 904.00 904.00

nr 2 904.00 1,808.00

5 nr 5 813.00 4,065.00

05 00 00 Metals

All metals works herein shall be completed in full compliance with the Drawings UB-WT- S201 and Specification.

Supply and fix 1900 x 2200mm stainless steel cover for inlet opening for sum pit,kind quality, fittings, fixtures, accessories as shown on Drawings and as per Specification.

Forming and fixed stainless steel steps with safety cage, 6500 mm height 475 mm switch including mechanical support as per the Drawing and Specification.

Supply and fix steel accessladder 3050 mm high 475 mm width with safety cage including mechanical support as per the Drawing and Specification.

Supply and fix steel access steps 20 mm dia at 300mm, 2360mm depth including mechanical support as per the Drawing and Specification.

Supply and fix steel access steps 20 mm dia at 300mm, 2360mm depth including mechanical support as per the Drawing and Specification.

Supply and fix steel access steps 20 mm dia at 300mm, 2360mm depth including mechanical support as per the Drawing and Specification.

Supply and fix 600mm dia heavy duty lockable cast iron cover and frame for manhole and bypasses

Page 1434: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Additional Items

6

As per Question and Answer No (514)6.1 Access cover 800 x 800mm nr 1 542.00 542.00

CF 2,425,545.00

BF 2,425,545.00

07 00 00 THERMAL AND MOISTURE PROTECTION

07 10 00 Damp proofing and Waterproofing

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

All works herein shall be completed in full compliance with the Drawings nr UB-CB-WT- S101, UB-WT-S201, UB-WT-S401, UB-WT-S402, UB-WT-S403, UB-WT-S404, UB-WT-S405 and Specification.

Page 1435: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1 m 278 41.00 11,398.00

2 Ditto bypasses; 250 mm thick m 63 16.00 1,008.00

3 Ditto Inlet; 250 mm thick m 20 16.00 320.00

4 Ditto manholes; 250 mm thick m 16 16.00 256.00

5 m² 574 5.00 2,870.00

6 m² 5296 37.00 195,952.00

7 m² 1087 31.00 33,697.00

8 m² 135 31.00 4,185.00

9 m² 8449 43.00 363,307.00

10 m² 61 43.00 2,623.00

Water stop for waterproofing works foe substructure 700mm width PVC water stop, vertical surface as concrete tank wall, width > 300mm (kind, quality, method of application, thickness as per the Drawings and Specification)

Waterproofing works for substructure with two coast of bitumen paint, vertical surface,as per the Drawings and Specification)

Waterproofing works for substructure with two layer of water proffing membrane, horizontal surface including top of slab width, by passes inlet. Manholes as per the Drawings and Specification)

Waterproofing works for substructure with two layer of water proffing membrane, horizontal surface including top of slab width, by passes inlet. Manholes as per the Drawings and Specification)

Waterproofing works for substructure with joint sealant, vertical surface, as per the Drawings and Specification)

Waterproofing works for tank, non toxic 1000 micron thick epoxy polysuphide coat, vertical and horizontal surface water tank, as per the Drawings and Specification)

Waterproofing works for tank, non toxic 1000 micron thick epoxy polysuphide coat, vertical and horizontal surface water tank, s as per the Drawings and Specification)

Page 1436: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 3,041,161.00

BF 3,041,161.00

07 00 00 Thermal and Moisture Protection

Additional Items

1

All works herein shall be completed in full compliance with the Drawings nr UB-CB-WT- S101, UB-WT-S201, UB-WT-S401, UB-WT-S402, UB-WT-S403, UB-WT-S404, UB-WT-S405 and Specification.

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Page 1437: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 3,041,161.00

BF 3,041,161.00

22 00 00 - PLUMBING

Vent Pipe Works

1 nr 66 475.00 31,350.00

2 nr 8 269.00 2,152.00

3 nr 1 228.00 228.00

All items hereunder to be describes specified code of practice and regulation, (kind, quality, method of application, thickness as per the Drawings nr UB-CB-WT- S101, UB-WT-S201, UB-WT-S401, UB-WT-S402, UB-WT-S403, UB-WT-S404, UB-WT-S405 and Specification.

Vent caps 300 mm diameter, galvanized, ( Type, nominal size, method of jointing, spacing and method of fixing supports, etc; as per the Drawings and Specification).

Air Vent caps 100 mm diameter, galvanized, ( Type, nominal size, method of jointing, spacing and method of fixing supports, etc; as per the Drawings and Specification).

Vent caps 80 mm diameter, aluminum with insect screen at inlet, ( Type, nominal size, method of jointing, spacing and method of fixing supports, etc; as per the Drawings and Specification).

Page 1438: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

4 nr 2 4377.00 8,754.00

5 nr 2 12473.00 24,946.00

Additional Items

6

Supply and fix electrically controlled level indicator ( Type, nominal size, method of fixing supports, etc; as per the Drawings and Specification).

Supply and install float valves 200 mm diameter with bell mount end (Type, nominal size, method of fixing supports, etc; as per the Drawings and Specification).

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Page 1439: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 3,108,591.00

BF 3,108,591.00

31 00 00 EARTHWORK

31 10 00 Site Clearing

1 Site preparation, clearing site vegetation 2639 2.00 5,278.00

31 23 16 Excavation

2 Excavation top soil for preservation, average depth 150mm m³ 2639 3.00 7,917.00

3 Excavating pits for tank depth excavation from 2 - 4m m³ 10,153 8.00 81,224.00

4 Ditto bypasses m² 333 8.00 2,664.00

5 Ditto Inlet m² 63 8.00 504.00

6 Ditto manholes m² 39 8.00 312.00

31 23 16 Backfill

7 m² 340 12.00 4,080.00

31 23 23.23 Compaction

8 m² 2703 3.00 8,109.00

31 23 16.26 Rock Removal

9 Disposal of excavated material, off site as stated in the Specification m² 10,247 4.00 40,988.00

All works herein shall be completed in full compliance with the Drawings nr UB-CB-WT- S101, UB-WT-S201, UB-WT-S401, UB-WT-S402, UB-WT-S403, UB-WT-S404, UB-WT-S405 and Specification.

m3

Filling to excavation, average thickness > 0.25 m, arising from excavated materials, all fill shall be compacted to 75% relative density for cohesion-less soils as per ASTM D4254/ASTM D4293 or 95% maximum density as determined by ASTM D698 for cohesive material, as per the Drawings and Specifications).

Surface treatment, compacting bottom of excavation, compaction to meet 85% of relative density for cohesion-less or 95% maximum density as determined by ASTM D1557 for cohesive materials per the Drawings and Specification).

Page 1440: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 3,259,667.00

BF 3,259,667.00

31 31 16 Termite Control

1 m² 2703 1.00 2,703.00

2 m² 1207 0.00 0.00

Additional Items

3

Termite control for the horizontal surface for tank and associate structures ( method and type of treatment as per he Drawings and Specification).

Termite control for vertical surface tank and associate structures ( method and type of treatment as per he Drawings and Specification).

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Page 1441: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for DOMESTIC AND FIRE WATER - WATER TANK

Page 1442: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CARRIED TO SUMMARY US Dollar 3,262,370.00

DOMESTIC AND FIRE WATER - GUARD HOUSE

03 00 00 - CONCRETE

03 11 13 Structural Cast-in Place Concrete Forming

1 m³ 1 188.00 188.00

03 31 00 Structural Concrete

2 m³ 1 434.00 434.00

3 m³ 1 797.00 797.00

4 m³ 3 383.00 1,149.00

5 m³ 0.5 838.00 419.00

6 m³ 5 680.00 3,400.00

7 mý 2 864.00 1,728.00

8 m³ 1 1198.00 1,198.00

Notwithstanding the Provisions of the Standard Method of Measurement, doors, frames, vision panels, decoration and ironmongery have been measured as a composite item and The Contractor should make due reference to the drawings and specification. No claim for lack or want of knoledge.

All concrete works herein shall be completed in full compliance with the Drawings nr UB-GH-S101 and Specification.

Plain Concrete, for blinding Beds, Thickness ≤ 150mm. Poured againts the compacted soil, as the Structural Notes and Specification.

Reinforced concrete 35 Mpa, foundations ( footings) (kind,quality, curing details etc. as stated in the Structural Notes and Specification.

Reinforced concrete 35 Mpa, for ground beams (kind,quality, curing details etc. as stated in the Structural Notes and Specification.

Reinfoced concrete beds 35 Mpa for slab with A393 welded wire mesh, on grade; thickness ≤ 150mm, poured againts the compacted soil kind quality, curing details etc.as stated in the Structural Notes and Specification.

Reinforced concrete for substructure columns 35 Mpa up to slab on grade; kind quality, curing details etc.as stated in the Structural Notes and Specification.

Reinforced concrete 35 Mpa for super structure, thickness 150mm, (kind,quality, curing details etc. as stated in the Structural Notes and Specification.

Reinforced concrete 35 Mpa for superstructure beams, (kind,quality, curing details etc. as stated in the Structural Notes and Specification.

Reinforced concrete for 35 Mpa substructure columns; kind quality, curing details etc.as stated in the Structural Notes and Specification.

Page 1443: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 9,313.00

BF 9,313.00

03 30 53 - Miscellaneous Cast-in-situ Cocrete

1 200mm wide x 200mm high reinforce concrete 35 Mpa lintel m 10 21.00 210.00

03 53 00 Concrete Topping

2 m² 28 17.00 476.00

3 m² 20 37.00 740.00

03 00 00 - CONCRETE

4

Sand cement/concrete screed for floors, width > 300mm, (thickness,kind quality,composition mix, nature of base method of construction. Layout and treatments,thermal insulation,moisture resistant treatment method of jointing, etc, as per the Drawings and Specification).

Sand cement/concrete screed for roof with A 252 mesh, width > 300mm, (thickness,kind quality,composition mix, nature of base method of construction. Layout and treatments,thermal insulation,moisture resistant treatment method of jointing, etc, as per the Drawings and Specification).

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Page 1444: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 10,739.00

BF 10,739.00

04 00 00 - Masonry

Page 1445: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

04 22 00 - Concrete Unit Masonry

Internal walls and Partitions

1 m² 9 39.00 351.00

External Walls

2 m² 9 37.00 333.00

3 m² 47 42.00 1,974.00

04 00 00 - Masonry

Additional Items

4

All Masonry works herein shall be completed in full compliance with the Drawings nr UB-GH-S101, UB-GH-A205, UB-GH-A506, UB-GH-A706 and Specification.

200mm thick CMU wall, internal vertical block work (kind, quality and size of blocks,; type of bond, mix of motar etc. to be included as per the details and Specification).

150mm thick CMU wall, parapet vertical block wall (kind, quality and size of blocks,; type of bond, mix of motar etc. to be included as per the details and Specification).

250mm thick CMU wall, external vertical block work (kind, quality and size of blocks,; type of bond, mix of motar etc. to be included as per the details and Specification).

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Page 1446: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 13,397.00

BF 13,397.00

06 00 00 WOOD, PLASTIC AND COMPOSITES

06 61 16 Solid Surfacing Fabrications

1 nr 1 2668.00 2,668.00

2 nr 1Price Included Above Item

06 00 00 Wood, Plastic,and Composites

Additional Items

Supply and fix solid acrylic counter top 1790mm long 600mm wide 1100 high including sink opening at kitchen as shown in the Drawings nr UB-GH-A206 and Specification.

Supply and fix solid acrylic counter top 1200mm long 150mm wide at guard house as shown in the Drawings nr UB-GH-A206 and Specification.

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Page 1447: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 16,065.00

BF 16,065.00

07 00 00 THERMAL AND MOISTURE PROTECTION

07 10 00 Damp proofing and Waterproofing

Page 1448: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Substructure Waterproofing

1 m² 6 5.00 30.00

2 m² 14 5.00 70.00

3 m² 27 2.00 54.00

Wet Area Waterproofing / Roof Waterproofing

4 m² 15 22.00 330.00

5 m² 6 22.00 132.00

6 m² 32 3.00 96.00

7 m² 32 23.00 736.00

All works herein shall be completed in full compliance with the Drawings UB-GH-AS206, and Specification.

Waterproofing works for substructure with two coast of bitumen paint, vertical surface,as per the Drawings and Specification)

Waterproofing works for substructure with two coast of bitumen paint, horizontal surface, as per the Drawings and Specification)

Waterproofing works for substructure with vapour barrier 250 microns, horizontal surface, as per the Drawings and Specification)

All works herein shall be completed in full compliance with the Drawings nr UB-GH-S101, UB-GH-AS206, and Specification.

Waterproofing works for wet area, vertical surface, s as per the Drawings and Specification)

Waterproofing works for wet area, horizontal surface, as per the Drawings and Specification)

Waterproofing membrane with geotextile layer on top for roof, horizontal surface, as per the Drawings and Specification)

100mm thick rigid insulation for water proofing works at roof, horizontal surface, as per the Drawings and Specification)

Page 1449: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 17,513.00

BF 17,513.00

07 00 00 THERMAL AND MOISTURE PROTECTION

Additional Items

1 The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Page 1450: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 17,513.00

BF 17,513.00

08 00 00 OPENINGS

Note

All works herein shall be completed in full compliance with the Doors & Windows Shcedule Drawings nr UB-GH-A206, UB-HG-A506, UB-HG-A705, UB-GH-A804 and Specification.

Notwithstanding the Provisions of the Standard Method of Measurement, doors, frames, vision panels, decoration and ironmongery have been measured as a composite item and The Contractor should make due reference to the drawings and specification. No claim for lack or want of knoledge will be entertained.

Page 1451: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1 nr 1 1338.00 1,338.00

2 nr 1 1227.00 1,227.00

Supply and fix wooden door, 1100mm wide x 2200mm high withl including wood frame, type D1, including paint all accessories and hardware including but not limited to hinges SHP type, DLH outside door lock with adjustable hydraulic closing back check and latching control , lever handles and latch, wall stop with roses and escutheons as stated in the Specification.

Supply and fix wooden door, 900mm wide x 2200mm high withl including wood frame, type D2, including paint all accessories and hardware including but not limited to hinges SHP type, DLH outside door lock with adjustable hydraulic closing back check and latching control , lever handles and latch, wall stop with roses and escutheons as stated in the Specification.

Page 1452: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 20,078.00

BF 20,078.00

08 51 13 Aluminum Windows

1 nr 2 976.00 1,952.00

2 nr 2 271.00 542.00

3 nr 1 542.00 542.00

08 83 00 Mirrors

4 nr 1 91.00 91.00

08 00 00 Openings

Additional Items

5

Supply and fix aluminum 12mm thick, clear tempered glass window, 1500mm wide x 2200mm high including frame, type W1, finished powder coated, all accessories and hardware including but not limited to hinges, handle lock weather tight strip etc; as stated in the Drawings and Specification.

Supply and fix aluminum glass window, 745mm wide x 1000mm high, 6 + 12 + 6mm clear tempered glass with fixed panel including frame, type W2, finished powder coated, all accessories and hardware including but not limited to hinges, handle lock weather tight strip etc; as stated in the Drawings and Specification.

Supply and fix aluminum 12mm thick, clear tempered glass window, 1000mm wide x 2200mm high including frame, type W1, finished powder coated, all accessories and hardware including but not limited to hinges, handle lock weather tight strip etc; as stated in the Drawings and Specification.

Supply and fix fixed mirror 500mm width x 900mm high (kind, quality, surface treatment, method of jointing, etc; as per the Drawings nr V4-903, and Specification)

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Page 1453: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 23,205.00

BF 23,205.00

09 00 00 - FINISHES

1 m² 33 22.00 726.00

2 m² 27 21.00 567.00

All works herein shall be completed in full compliance with the Schedule Drawings nr UB-GH-A206, UB-HG-A506, UB-HG-A705, UB-GH-A804 and Specification.

Plastering for walls to receive paint finish, width > 300mm. (thickness, kind quality, composition, mix materials, nature of base, method of construction layout and treatment, thermal insulation, moisture resistant treatment, method of jointing and joint reinforcement etc, as per the Drawings nr UB-GH-A206, UB-HG-A506, UB-HG-A705, UB-GH-A804 and Specification.

Plastering for walls to receive tiling, width > 300mm. (thickness, kind quality, composition, mix materials, nature of base, method of construction layout and treatment, thermal insulation, moisture resistant treatment, method of jointing and joint reinforcement etc, as per the Drawings nr UB-GH-A206, UB-HG-A506, UB-HG-A705, UB-GH-A804 and Specification.

Page 1454: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

External Walls

3 m² 28 29.00 812.00

4 m² 25 29.00 725.00

09 30 13 Ceramic Tiling

Floor Tiling

5 m² 3 34.00 102.00

Self coloured rendering ( pre coloured mineral wall coating ) for external walls at second floor, roof and water tank area, width > 300mm, (thickness, kind quality, composition, mix materials, nature of base, method of construction layout and treatment, thermal insulation, moisture resistant treatment, method of jointing and joint reinforcement etc, as per the Drawings nr UB-GH-A206, UB-HG-A506, UB-HG-A705, UB-GH-A804 and Specification.

Self coloured rendering ( pre coloured mineral wall coating ) for parapet area, width > 300mm, (thickness, kind quality, composition, mix materials, nature of base, method of construction layout and treatment, thermal insulation, moisture resistant treatment, method of jointing and joint reinforcement etc, as per the Drawings nr UB-GH-A206, UB-HG-A506, UB-HG-A705, UB-GH-A804 and Specification.

Unglazed ceramic tile flooring at toilet, level or to falls ≤ 15 from horizontal, fixed over cement sand screed ( screed measured separately). Thickness, method of construction, layout and treatment, method of jointing, etc; as per the Drawings nr UB-GH-A206, UB-GH-A804 and Specification.

Page 1455: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 26,137.00

BF 26,137.00

Floor Tiling

1 m² 16 55.00 880.00

Threshold

2 1100mm x 200mm width threshold nr 1 55.00 55.00

3 900mm x 200mm width threshold nr 1 44.00 44.00

Wall tiling

4 m² 27 37.00 999.00

09 50 00 Ceilings

Ceiling - Painting

5 m² 19 11.00 209.00

09 91 00 - Painting

Wall - Painting

6 m² 29 12.00 348.00

7 m² 4 11.00 44.00

Non-slip porcelain, level or to falls only ≤ 15 from horizontal, fixed over cement sand screed ( screed measured separately). Thickness, method of construction, layout and treatment, method of jointing, etc; as per the Drawings nr UB-GH-A506, UB-GH-A706 and Specification.

Glazed ceramic tile for wallsl width > 300mm, fixed over cement sand plaster, Thickness, method of construction, layout and treatment, method of jointing, etc; as per the Drawings and Specification.

Emulsion painting on exposed for ceiling, girth ≤ 300mm, (kind, quality of materials, prepatory works, priming coat (1nr), finishing coat (1nr), method of application, etc; as per the Drawings and Specification.

Fine textured painting for walls, girth > 300mm, (kind, quality of materials, prepatory works, priming coat, finishing coat, method of application, etc; as per the Drawings and Specification.

Painting for walls, girth > 300mm, (kind, quality of materials, prepatory works, priming coat, finishing coat, method of application, etc; as per the Drawings and Specification.

Page 1456: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 28,716.00

BF 28,716.00

09 00 00 - FINISHES

Additional Items

1

As per client answer for question No 282

Floor Tiling

1.1 m2 31 32.00 992.00

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Terrazzo tiles at Roof, size 400x400mm as per dwg No (UB-GWH-A804)

Page 1457: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 29,708.00

BF 29,708.00

Page 1458: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

10 00 00 - SPECIALTIES

10 28 00 - Toilet, Bath and Laundry Accessories

1 Paper towel dispenser (PTD) nr 1 21.00 21.00

2 Soap dispenser (SD) nr 1 22.00 22.00

3 Mixer tap for wash basin nr 1 167.00 167.00

4 Towel ring nr 1 35.00 35.00

5 Robe hook nr 1 17.00 17.00

6 Towel bar nr 1 31.00 31.00

7 Hand dryer nr 1 1155.00 1,155.00

10 44 16.13 Portable Fire Extinguishers

8 nr 1 54.00 54.00

Supply & install Plumbing Fixture as shown in Drawings nr UB-GH-A206, UB-HG-A506, UB-HG-A705, UB-GH-A804 and Specification.

All items hereunder to be described with kind, quality, size, method of fixing, etc; as per the Drawings nr SB-GH-M201 and Specification.

Supply & install portable fire extinguisher (6 Kg multipurpose dry chemical)

Page 1459: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 31,210.00

BF 31,210.00

22 00 00 PLUMBING

22 05 23 General-Duty Valves for Plumbing Piping

1 Pressure reducing valve nr 1 337.00 337.00

2 Isolating valve nr 1 26.00 26.00

22 11 16 Domestic Water Piping

3 m 10 19.00 190.00

4 m 6 14.00 84.00

22 13 16 Sanitary Waste and Vent Piping

Sanitary Pipe Works

All Items hereunder to be described specified code of practice and regulation, kind quality, size method of fixing, finishes or surface treatments etc,as per the Drawings nr SB-GH-M203 and Specification)

Cold water supply pipes 25 mm diameter, straight, ( Type, nominal size, method of jointing, spacing and method of fixing supports, etc, as per the Drawings and Specification.

Hot water supply pipes 25 mm diameter, straight, ( Type, nominal size, method of jointing, spacing and method of fixing supports, etc, as per the Drawings and Specification.

Page 1460: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

5 m 8 29.00 232.00

6 m 1 12.00 12.00

7 m 1 10.00 10.00

8

9 m 8 12.00 96.00

Condensate Drain Pipe Work

10 m 3 9.00 27.00

CF 32,224.00

BF 32,224.00

22 33 00 Electric Domestic Water Heaters

Waste water pipes 110 mm diameter, straight, ( Type, nominal size, method of jointing, spacing and method of fixing supports, etc, as per the Drawings and Specification.

Waste water pipes 50 mm diameter, straight, ( Type, nominal size, method of jointing, spacing and method of fixing supports, etc, as per the Drawings and Specification.

Waste water pipes 40 mm diameter, straight, ( Type, nominal size, method of jointing, spacing and method of fixing supports, etc, as per the Drawings and Specification.

Soil pipes 110 mm diameter for roof drain. straight, ( Type, nominal size, method of jointing, spacing and method of fixing supports, etc, as per the Drawings and Specification.

Vent pipes 50 mm diameter. straight, ( Type, nominal size, method of jointing, spacing and method of fixing supports, etc, as per the Drawings and Specification.

Condensate drain pipes 20 mm diameter. straight, ( Type, nominal size, method of jointing, spacing and method of fixing supports, etc, as per the Drawings and Specification.

Page 1461: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1 nr 1 278.00 278.00

22 40 00 Plumbing Fixtures

2 Floor Drain (FD) 50mm nr 1 193.00 193.00

3 Floor Drain (FD) 40mm nr 1 193.00 193.00

4 Floor clean out nr 1 204.00 204.00

5 Roof drain (75 dia) nr 2 173.00 346.00

6 Wash basin (WB) oval shape nr 1 136.00 136.00

7 Perennial spray nr 1 39.00 39.00

8 WC (Arabian) nr 1 462.00 462.00

Additional Items

9

Supply and install electric water heater. 50L, 1200W, 220/1/060Hz horizontal type (item to be described with information such as appropriate to the procurement, design, supply, execution, type, kind, quality, size method of fixing, specified codes of practice, etc; as per the Equipment schedule, Drawings nr SB-GH-M203 and Specification.

All items hereunder to be described with, kind, quality, size, natur of base, method of fixing, etc; as per the Drawings nr SB-GH-M203 and Specification.

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Page 1462: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 34,075.00

BF 34,075.00

23 34 00 HVAC Fans

1 Exhaust Fan; 25 L/S, 0.05KW 220/1/60Hz wall mounted nr 1 134.00 134.00

2 Exhaust Fan; 50 L/S, 0.05KW 220/1/60Hz wall mounted nr 1 134.00 134.00

3 nr 1 1191.00 1,191.00

Additional Items

4

23 00 00 - HEATING, VENTILATING, AND AIR CONDITONING (HVAC)

All HVAC works shall be completed as per the Drawings and Specification

All Items described hereunder to be capacity,design, supply, execution, type, kind quality, size,,method of fixing, specified codes of practice,etc, as per the Drawings and Specification)

All Items hereunder to be described with information such as appropriate to the procurement, capacity,design, supply, execution, type, kind quality, size,,method of fixing, specified codes of practice,etc, as per the Drawings and Specification)

Supply ans install FCU/ACCU; 265L/S. 3.5 Kw, 220/1/60Hz 2.6 total load, 2.6 sensible load DB" C13.6/13.4, Hi deco split.

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Page 1463: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 35,534.00

BF 35,534.00

26 00 00 - ELECTRICAL

All works hereunder shall be completed as per the Drawings and Specification)

Page 1464: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

26 05 19 Low Voltage Electrical power Conductors and Cables

1 m 47 23.00 1,081.00

26 05 26 Grounding and Bonding for Electrical System

2 Grounding System Item 1 1411.00 1,411.00

26 41 13.13 Lightning Protection for Building

3 Lightning system Item 1As per Q&A # 374 - Not Required

26 05 33.13 Conduit for Electrical Systems

4 Item 1 740.00 740.00

26 24 16 Panel Boards

5 Lightning and power panel nr 1 897.00 897.00

All Items hereunder to be described with information such as appropriate to the procurement, capacity,design, supply, execution, type, kind quality, size,,method of fixing, specified codes of practice,etc, as per the Drawings and Specification)

Feeder cables, CU/XLPE/PVC + CU/PVC type, 1 (4C 25mm² + 16mm² (E)

All Items hereunder to be described with information such as appropriate to the procurement, capacity,design, supply, execution, type, kind quality, size,,method of fixing, specified codes of practice,etc, as per the Drawings and Specification)

All Items hereunder to be described with information such as type, kind quality, size,,method of fixing, specified codes of practice,etc, as per the Drawings and Specification)

Cables and conduits in final circuits, cable installation, size, type and description of final circuits ( sockets, switch etc;)

All Items hereunder to be described with information such as type, kind quality, size,,method of fixing, specified codes of practice,etc, as per the Drawings and Specification)

Page 1465: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 39,663.00

BF 39,663.00

26 27 13 Electricity Metering

1

26 27 26 Wiring Devices

Switches & Push Buttons

2 One way one gang switch 15A nr 2 10.00 20.00

3 One way two gang switch, 15 A nr 1 12.00 12.00

Power Outlets

4 Duplex receptable outlet, 230V, 20A normal power supply nr 4 19.00 76.00

5 Duplex receptable outlet, 230V, 20A power supply with water proof nr 3 58.00 174.00

6 nr 1 19.00 19.00

7 Non-fusible disconnect switch, single pole nr 1 697.00 697.00

26 28 16.13 Enclosed Circuit Breakers

All Items hereunder to be described with information such as type, kind, rated capacity, method of fixing,cores reference to Specification, fuses, background, specified codes of practice ,etc, as per the Drawings and Specification)

All Items hereunder to be described with information such as appropriate to the procurement, type, kind quality, size,,method of fixing, specified codes of practice,etc, as per the Drawings and Specification)

Duplex receptable outlet, 230V, 20A connected to emergency power supply

Page 1466: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 40,661.00

BF 40,661.00

26 50 00 Lighting

1 nr 2 427.00 854.00

All Items hereunder to be described with information such as type, kind quality, size,,method of fixing, specified codes of practice,etc, as per the Drawings and Specification)

All Items hereunder to be described with information such as type, kind quality, size,,method of fixing, specified codes of practice,etc, as per the Drawings nr UB-GH-EL-801 and Specification)

Recess mounted drawn modular luminaire with frame diffuser or louvers is held by means of hinges & twist locks, And installed with 2 x 36 W 18 lamp for electronic control gears.(LH1)

Page 1467: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2 nr 2 210.00 420.00

3 nr 3 1485.00 4,455.00

Additional Items

4

4.1 nr 2 64.00 128.00

4.2 nr 1 28.00 28.00

4.3 Power for FCU nr 1 100.00 100.00

Recessed mounted CFL down light installed with 2 x 26 CFL for electronic control gears (G1 )

Wall mounted bulkhead outdoor landscape clear with a 100W/220/60Hz mercury vapour elliptical lamp, prismatic pattern mouled polycarbonate diffuser cover of ip-65 (BH2)

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Fusible disconnect switch plate, double poles, 30A, 220V, 60HZ for wall mounted exhaust fan

Water heater receptable outlet with single pole switch 230V, 20A normal supply

Page 1468: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 46,646.00

BF 46,646.00

27 00 00 COMMUNICATIONS

Telecommunication / Low Current

STRUCTURED CABLING SYSTEM

27 21 29 Data Communication switches and Hubs

27 21 33 Data Communication Wireless Access Points

1 Information outlet, flush type, 1 data, 1 talephone nr 1 48.00 48.00

2 IP fixed type cctv, wall mounted outdoor camera ( weather proof ) nr 1 1520.00 1,520.00

3 Card reader, amart card nr 1 235.00 235.00

4 Electronetic door latch nr 1 383.00 383.00

5 Magnetic door contact switch nr 1 222.00 222.00

6 Request to exit button nr 1 309.00 309.00

7 Pull box nr 1 included in the above

27 00 00 Communications

All Items hereunder to be described with information such as type, kind quality, size,,method of fixing, specified codes of practice,etc, as per the Drawings nr UB-GH & YR-T201, T301 and Specification)

Supply, Install, test connect and commission inclusive of all cabling, conduits and containment, socket outlets, all in accordance with the relevant service provider regulations, rules recommendation and requirements and in accordance with the Specifications and drawings.

Page 1469: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Additional Items

8

ADDITIONAL

8.1 Control Panel for Access Control nr 1 1779.00 1,779.00

CF 51,142.00

BF 51,142.00

28 00 00 ELECTRONIC SAFETY AND SECURITY

28 31 00 Fire Detection and Alarm

1 Supply, install smoke detector nr 1 110.00 110.00

2 Supply, install smoke and heat detector nr 1 139.00 139.00

3 Multisensor detector nr 1 127.00 127.00

4 Manual pull station - 1.2 meters from FFL to the centre of the device nr 1 110.00 110.00

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Page 1470: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

5 nr 1 123.00 123.00

6 Fault islator - ceiling mounted or as per site situation nr 1 110.00 110.00

7 nr 1 110.00 110.00

28 00 00 Electronic Safety and Security

Additional Items

8

Sounder/fire alarm, bel/horn - 0.30 meters below from ceiling line to the centre of the device.

Control module - 0.20 meters below from ceiling line to the centre of the device

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Page 1471: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 51,971.00

BF 51,971.00

31 00 00 EARTHWORK

31 10 00 Site Clearing

1 Site preparation, clearing site vegetation m² 25 2.00 50.00

31 23 16 Excavation

2 Excavating top soil for preservation, average depth 150mm. m² 25 3.00 75.00

3 Excavating pits,depth excavation not exceeding 2 m. m³ 15 8.00 120.00

31 23 23.13 Backfill

4 m³ 10 12.00 120.00

31 23 23.23 Compaction

5 m² 27 3.00 81.00

31 31 16.26 Rock Removal

6 Disposal of excavated material, off site as stated in the Specification m³ 5 4.00 20.00

31 31 16 Termote Control

7 m² 32 1.00 32.00

All works herein shall be completed in full compliance with the Drawings nr UB-GH-S101 and Specification.

Filling to excavation, average thickness > 0.25 m, arising from excavated materials, all fill shall be compacted to 75% relative density for cohesion-less soils as per ASTM D4254/ASTM D4293 or 95% maximum density as determined by ASTM D698 for cohesive materials, as per the Drawings and Specification.

Surface treatment, compacting bottom of excavation, compaction to meet 85% of relative density for cohesion-less or 95% maximum density as determined by ASTM D1557 for cohesive materials per the Drawings and Specification).

Termite control for the horizontal surface (method and type of treatment as per the Drawings and Specification)

Page 1472: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

8 m² 36 1.00 36.00

CF 52,505.00

BF 52,505.00

31 00 00 EARTHWORK

Additional Items

1

Termite control for the vertical surface (method and type of treatment as per the Drawings and Specification)

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Page 1473: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836
Page 1474: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 52,505.00

BF 52,505.00

33 00 00 UTILITIES

1 nr 1 1249.00 1,249.00

Additional Items

2

Supply and install water meter as per the Drawings Number and Specification.

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Page 1475: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for DOMESTIC AND FIRE WATER - GUARD HOUSE

CARRIED TO SUMMARY US Dollar 53,754.00

DOMESTIC AND FIRE WATER - PUMP HOUSE AND ANNEX

03 11 13 Structural Cast-in Place Concrete Forming

1 m³ 24 188.00 4,512.00

03 31 00 Structural Concrete

Notwithstanding the Provisions of the Standard Method of Measurement of Building Works Seventh Edition, 1988 (SMM7) the following,concrete works are measured m³/m including. reinforcement bars and formworks. The Contractor is to include for cost of reinforcement and formwork with concrete works. No additional charge or cost for reinforcement and formwork separately will be entertained due to lack or want of knowledge.

All concrete works herein shall be completed in full compliance with the Drawings nr UB-PA-S101, UB-PA-S201, UB-PA-S401, UB-PA-S402 and Specification.

Plain Concrete, 20 Mpa for blinding Beds, Thickness ≤ 150mm. Poured againts the compacted soil, as the Structural Notes and Specification.

Page 1476: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2 m³ 17 376.00 6,392.00

3 m³ 80 450.00 36,000.00

4 m³ 106 648.00 68,688.00

5 m³ 18 687.00 12,366.00

6 m³ 15 772.00 11,580.00

7 m³ 33 501.00 16,533.00

Reinforced concrete 35 Mpa, foundations ( footings):kind,quality, curing details etc. as stated in the Structural Notes and Specification.

Reinforced concrete 35 Mpa, foundations ( Raft ) :kind,quality, curing details etc. as stated in the Structural Notes and Specification.

Reinforced concrete 35 Mpa for superstructure retaining walls, (kind quality, curing details etc. as stated in the Structural Notes and Specification.

Reinforced concrete 35 Mpa for superstructure parapet walls on roof 200mm thickness, (kind quality, curing details etc. as stated in the Structural Notes and Specification.

Reinforced concrete 35 Mpa for ground beams; kind,quality, curing details etc. as stated in the Structural Notes and Specification.

Reinfoced concrete beds 35 Mpa for slab with A393 welded wire mesh, on grade; thickness ≤ 150mm, poured againts the compacted soil kind quality, curing details etc.as stated in the Structural Notes and Specification.

Page 1477: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 156,071.00

BF 156,071.00

Structural Concrete ( Cont'd )

1 m³ 2 742.00 1,484.00

2 m³ 34 650.00 22,100.00

3 m³ 5 608.00 3,040.00

4 m³ 1 445.00 445.00

5 m³ 25 831.00 20,775.00

6 m³ 12 1035.00 12,420.00

7 m³ 7 750.00 5,250.00

03 41 00 Precast Structural Concrete

8 m³ 137 105.00 14,385.00

03 37 13 Shot Crete

9 m³ 275 47.00 12,925.00

03 30 53 - Miscellaneous Cast-in-situ Concrete

10 250mm wide x 200mm high reinforced concrete 35 Mpa for lintel m 15 27.00 405.00

11 150mm wide x 200mm high reinforced concrete 35 Mpa for lintel m 10 16.00 160.00

Reinforced concrete for superstructure columns 35 Mpa up to slab on grade, (kind quality, curing details etc. as stated in the Structural Notes and Specification.

Reinforced concrete 35 Mpa for superstructure slab, thickness, 200mm (kind quality, curing details etc. as stated in the Structural Notes and Specification.

Reinforced concrete 35 Mpa for superstructure slab, thickness, 250mm (kind quality, curing details etc. as stated in the Structural Notes and Specification.

Reinforced concrete 35 Mpa for concrete pads at roof slab. thickness, 100mm (kind quality, curing details etc. as stated in the Structural Notes and Specification.

Reinforced concrete 35 Mpa superstructure beams . (kind quality, curing details etc. as stated in the Structural Notes and Specification.

Reinforced concrete 35 Mpa for superstructure columns , (kind quality, curing details etc. as stated in the Structural Notes and Specification.

Reinforced concrete 35 Mpa for steps. thickness, 100mm (kind quality, curing details etc. as stated in the Structural Notes and Specification.

Reinforced precast HCS 320 slab for superstructure roof slabs, thickness, 100mm (kind quality, curing details etc. as stated in the Structural Notes and Specification.

Shot Crete for substructure underground pump room wall (200mm thick Block CMU as per Dwg No. UB-WT-S401)

Page 1478: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 249,460.00

BF 249,460.00

03 53 00 Concrete Topping

1 m² 135 17.00 2,295.00

2 m² 250 17.00 4,250.00

3 m² 300 37.00 11,100.00

Additional Items

Sand cement/concrete screed for floors, width > 300mm, (thickness,kind quality,composition mix, nature of base method of construction. Layout and treatments,thermal insulation,moisture resistant treatment method of jointing, etc, as per the Drawings and Specification).

Sand cement/concrete screed for protection screed for substructure, width > 300mm, (thickness,kind quality,composition mix, nature of base method of construction. Layout and treatments,thermal insulation,moisture resistant treatment method of jointing, etc, as per the Drawings and Specification).

Sand cement/concrete screed for roof with A 252 mesh, width > 300mm, (thickness,kind quality,composition mix, nature of base method of construction. Layout and treatments,thermal insulation,moisture resistant treatment method of jointing, etc, as per the Drawings and Specification).

Page 1479: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

4

CF 267,105.00

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Page 1480: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

BF 267,105.00

04 22 00 - Masonry

04 22 00 - Concrete Unit Masonry

Internal walls and Partitions

1 m² 174 37.00 6,438.00

External walls

2 m² 375 42.00 15,750.00

Additional Items

3

All Masonry works herein shall be completed in full compliance with the Drawings nr UB-A001, UB-A002, UB-PA-A201, UB-PA-A202, UB-PA-A501, UB-PA-A502, UB-PA-A503, UB-PA-A701, UB-PA-A702, UB-PA-A703, UB-PA-A801 and Specification.

150mm thick CMU wall, internal vertical block work, (kind, quality and size of blocks,; type of bond, mix of motar etc. to be included as per the Specification).

250mm thick CMU wall, external vertical block work, (kind, quality and size of blocks,; type of bond, mix of motar etc. to be included as per the Specification).

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Page 1481: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 289,293.00

BF 289,293.00

05 00 00 METALS

05 70 00 Decorative Metal

1 m 16 294.00 4,704.00

2 nr 1 1269.00 1,269.00

3 nr 1 474.00 474.00

4 nr 1 702.00 702.00

All metal works herein shall be completed full incompliance with the Drawings UB-PA-A701 and Specification.

Supply and fix 50mm x 50mm 1.1 high stainless steel guard rails for loading bay, floorl mounted, kind, quality, fittings, fixtures, accessories as per Drawings and as per Specification.

Supply and fixed galvanized steel ladder 8025 mm high 475 width with safety cage including mechanical coated hand rails for balcony, floor mounted, kind, quality, fittings, fixtures, accessories as per Drawings and as per Specification.

Supply and fixed galvanized steel ladder 3000 mm high 475 width with safety cage including mechanical supports as per Drawings and as per Specification.

Supply and fixed galvanized steel ladder 4450 mm high 475 width with safety cage including mechanical supports as per Drawings and as per Specification.

Page 1482: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

5 m 25 204.00 5,100.00

6 m 23 122.00 2,806.00

7 m 11 159.00 1,749.00

05 00 00 METALS

Additional Items

8

As per Question and Answer No (272)

8.1 Sump pit cover 1500 x 1500 nr 1 813.00 813.00

8.2 Sump pit cover 1000 x 1450 nr 2 524.00 1,048.00

8.3 Steel stair including handrail, 7200mm high x 1200mm wide nr 1 12357.00 12,357.00

8.4 Steel stair including handrail, 3700mm high x 900mm wide nr 2 6350.00 12,700.00

Supply and fixed steel granting for floor drain at pump room kind, quaity, fittings, fixtures, accessories as shown on Drawing and Specification.

Forming and fixing 600mm width cable trench heavy duty, ductile iron checker plate as per the Drawing and Specification.

Forming and fixing 780mm width cable trench heavy duty, ductile iron checker plate as per the Drawing and Specification.

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Page 1483: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 333,015.00

BF 333,015.00

06 00 00 WOOD, PLASTIC, AND COMPOSITES

06 41 00 Architectural Wood Casework

1 nr 1 6045.00 6,045.00

06 61 16 Solid Surfacing Fabrications

2 nr 1 1325.00 1,325.00

Additional Items

3

Supply and fix kitchen under counter cabinets ( 2680mm + 2620mm) long 600mm wide ( counter tops measured separately) at kitchen with wall cabinet MDF melamine laminated with aluminum edge, base & overhead cabinets with polished chrome cabinet pull handles; and all accessories, as per the Drawing nr UB-PA-A202 and Specification.

Supply and fix solid acrylic counter top shaped (2680 + 2620mm) long 600mm wide with opening for wash basin as shown in the Drawing nr UB-PA-A200, A202 and Specification.

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Page 1484: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 340,385.00

BF 340,385.00

07 00 00 THERMAL AND MOISTURE PROTECTION

07 10 00 Damp proofing and Waterproofing

Substructure Waterproofing

1 m 47 16.00 752.00

2 m² 225 5.00 1,125.00

3 m² 175 2.00 350.00

4 m² 40 5.00 200.00

All works herein shall be completed in full compliance with the Drawings nr UB-PA-S101, UB-PA-S201 UB-PA-S202, UB-PA-S401, UB-PA-S402, and Specification.

Waterproofing works for substructure 250mm PVC water stop, vertical surface at retaining wall, as per the Drawings and Specification)

Waterproofing works for substructure with two coast of bitumen paint, vertical surface,s as per the Drawings and Specification)

Waterproofing works for substructure with vapor barrier 250 microns, horizontal surface as per the Drawings and Specification)

Waterproofing works for substructure with two coast of bitumen paint, horizontal surface, as per the Drawings and Specification)

Page 1485: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

5 m² 230 36.00 8,280.00

6 m² 105 30.00 3,150.00

7 m² 285 30.00 8,550.00

CF 362,792.00

BF 362,792.00

Wet Area Waterproofing / Roof Waterproofing

Waterproofing works for substructure with two layer of water proofing membrane,horizontal surface, as per the Drawings and Specification)

Waterproofing works for substructure with two layer of water proofing membrane,vertical surface, as per the Drawings and Specification)

Waterproofing works for substructure with two layer of water proofing membrane with protected board, vertical surface, width > 300mm (kind, quality, method of application, thickness as per the Drawings and Specification)

All works herein shall be completed in full compliance with the Drawings nr UB-PA-S101, UB-PA-S201 UB-PA-S202, UB-PA-S401, UB-PA-S402, and Specification.

Page 1486: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1 m² 11 22.00 242.00

2 m² 6 22.00 132.00

3 m² 300 39.00 11,700.00

4 m² 300 23.00 6,900.00

5 m 83 32.00 2,656.00

6 m 30 396.00 11,880.00

07 00 00 Thermal and Moisture Protection

Additional Items

7

Waterproofing works for wet area, vertical surface, width > 300mm 1200mm high (kind, quality, method of application, thickness as per the Drawings and Specification)

Waterproofing works for wet area, horizontal surface, width > 300mm (kind, quality, method of application, thickness as per the Drawings and Specification)

Waterpoofing membrane with geotextile layer on top for roof, horizontal surface, width > 300mm (kind, quality, method of application, thickness as per the Drawings and Specification)

100mm thick rigid insulation for water proofing works at roof, horizontal surface, width > 300mm (kind, quality, method of application, thickness as per the Drawings and Specification)

Supply and fix mastic sealant for vertical surface wide ≤ 200 mm at cable trench and external steps as per the Drawings and Specification)

Supply and fix neoprene bearing pad for horizontal surface, s as per the Drawings and Specification)

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Page 1487: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 396,302.00

BF 396,302.00

08 00 00 OPENINGS

Note

08 13 00 - METAL DOORS

1 nr 1 2183.00 2,183.00

2 nr 2 1839.00 3,678.00

All works herein shall be completed in full compliance with the Doors & Windows Schedule Drawings nr UB-PA-2000, UB-PA-201 UB-PA-203, UB-PA-801,and Specification.and Specification.

Notwithstanding the Provisions of the Standard Method of Measurement, doors, frames, vision panels, decoration and ironmongery have been measured including. reinforcement bars and formworks. The Contractor is to include for cost of reinforcement and formwork with concrete works. No additional charge or cost for reinforcement and formwork separately will be entertained due to lack or want of knowledge.

Supply and fix steel door 2000mm wide x 2200mm high with 875 wide x 850 high louver including steel frame, type D1 including paint, all accessories and hardware including but not limited to hinges HDH type. SST door lock with adjustable hydraulic closing back check and latching control, outside and inside door lock, lever handles and latch, wall stop with roses and escutheons as stated in the Drawings and Specification)

Supply and fix steel door 1600mm wide x 2200mm high with 675 wide x 850 high louver including steel frame, type D2 including paint, all accessories and hardware including but not limited to hinges HDH type. SST door lock with adjustable hydraulic closing back check and latching control, outside and inside door lock, lever handles and latch, wall stop with roses and escutheons as stated in the Drawings and Specification)

Page 1488: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3 nr 3 1576.00 4,728.00

08 14 00 - Wood Doors

4 nr 6 1227.00 7,362.00

5 nr 1 1226.00 1,226.00

CF 415,479.00

BF 415,479.00

OPENINGS (Cont'd )

1 nr 1 3568.00 3,568.00

08 51 13 Aluminum Windows

Supply and fix steel door 900mm wide x 2200mm high with 800 wide x 850 high louver including steel frame, type D3 including paint, all accessories and hardware including but not limited to hinges HDH type. SST door lock with adjustable hydraulic closing back check and latching control, outside and inside door lock, lever handles and latch, wall stop with roses and escutheons as stated in the Drawings and Specification)

Supply and fix wooden flush door, 900mm wide x 2200mm high including frame, type D4, including paint all accessories and hardware including but not limited to hinges SHP type, DLH door lock with adjustable hydraulic closing back check and latching control, outside and inside door lock, lever handles and latch, wall stop with roses and escutheons as stated in the Drawings and Specification)

Supply and fix wooden flush door, 800mm wide x 2200mm high including frame, type D5, including paint all accessories and hardware including but not limited to hinges SHP type, DLH door lock with adjustable hydraulic closing back check and latching control, outside and inside door lock, lever handles and latch, wall stop with roses and escutheons as stated in the Drawings and Specification)

Supply and fix steel rolling shutter, 3000mm wide x 2500mm high including steel frame, type D6 including paint, all accessories. and hardware including but not limited to door lock outside, lever handles as stated in the drawings and specifications.

Page 1489: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2 nr 3 326.00 978.00

08 00 00 OPENINGS

Additional Items

3

As per Question and Answer No (271)

Aluminum Windows

3.01 nr 2 271.00 542.00

3.02 Ditto, size 600 x 1000 mm high Type (W3) nr 2 217.00 434.00

3.03 Mirror nr 1 82.00 82.00

Supply and fix aluminum 6 + 12 + 6mm clear tempered glass window, 2000mm wide x 600mm high, with open glass door window fixed panel including frame, type W1, finished, all accessories. and hardware including but not limited to hinges handle, lock weather tight strip etc; as stated in the drawings and specifications.

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Supply and fix aluminum 6 + 12 + 6mm clean tempered glass window 800 x 1000 mm high Type (W2) as per dwg No (UB-PA-A801)

Page 1490: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 421,083.00

BF 421,083.00

09 00 00 - FINISHES

09 23 00 - Gypsum Plastering

1 m² 6 0.00 0.00

09 24 00 Cement Plastering

2 m² 978 22.00 21,516.00

3 m² 38 21.00 798.00

All works herein shall be completed in full compliance with the Schedule Drawings nr UB-A001, UB-PA-A200 UB-PA-A201, UB-PA-A202 UB-PA-A203, UB-PA-A501,, UB-PA-A502, UB-PAA503, UB-PA-A701, UB-PA-A702, UB-PA-703, UB-PA-A801 and Specification.and Specification.

Note: Notwithstanding the provision in the method of measurement Gypsum Boarding, Plastering and Studwork is deemed to include 50 x 50 studs at minimum 400 centres, 12.5mm gypsum board, scrimming skim finish, stop and angle beads, The Contractor is to include for all works to complete No. claim for want of knoledge will be entertained.

Gypsum plastering for ceiling to receive paint finish at toilets, width > 300mm, (thickness, kind quality, composition, mix materials, nature of base, method of construction layout and treatment, thermal insulation, moisture resistant treatment, method of jointing and joint reinforcement etc, as per the Drawings nr UB-PA-A202, UB-PA-A801 and Specification).

Plastering for walls to receive paint finish, width > 300mm, (thickness, kind quality, composition, mix materials, nature of base, method of construction layout and treatment, thermal insulation, moisture resistant treatment, method of jointing and joint reinforcement etc, as per the Drawings UB-PA-A202, UB-PA-A801 and Specification).

Plastering for walls to receive tiling at wet areas, width > 300mm, (thickness, kind quality, composition, mix materials, nature of base, method of construction layout and treatment, thermal insulation, moisture resistant treatment, method of jointing and joint reinforcement etc, as per the Drawings nr UB-PA-A202, UB-PA-A801 and Specification).

Page 1491: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

External Walls

4 m² 375 29.00 10,875.00

CF 454,272.00

BF 454,272.00

FINISHES (Cont'd )

1 m² 176 29.00 5,104.00

09 30 13 Ceramic Tiling

Floor Tiling

Self coloured rendering ( pre coloured mineral wall coating ) for external walls width > 300mm, (thickness, kind quality, composition, mix materials, nature construction layout and treatment, thermal insulation, moisture resistant treatment, method of jointing etc, as per the Drawings nr UB-PA-A202, UB-PA-A801 and Specification).

Self coloured rendering ( pre coloured mineral wall coating ) for parapet walls at roof area, width > 300mm, (thickness, kind quality, composition, mix materials, nature construction layout and treatment, thermal insulation, moisture resistant treatment, method of jointing etc, as per the Drawings nr UB-PA-A202, UB-PA-A801 and Specification).

Page 1492: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2 m² 92 33.00 3,036.00

3 m² 17 32.00 544.00

4 m² 20 31.00 620.00

5 m² 6 31.00 186.00

6 m² 300 33.00 9,900.00

7 m² 18 203.00 3,654.00

8 m² 17 45.00 765.00

Terrazo tile flooring, level or to falls only ≤ 15 * from horizontal, fixed over cement sand screed (screed measured seaparately). Thickness, method of construction, layout and treatments, method of jointing etc, as per the Drawings nr UB-PA-A202, UB-PA-A801 and Specification).

Concrete tiles at loading bay, levels to falls only ≤ 15 * from horizontal, fixed over cement sand screed (screed measured seaparately). Thickness, method of construction, layout and treatments, method of jointing etc, as per the Drawings nr UB-PA-A202, UB-PA-A801 and Specification).

Unglazed ceramic tile flooring, level or to falls only ≤ 15 * from horizontal, fixed over cement sand screed (screed measured seaparately). Thickness, method of construction, layout and treatments, method of jointing etc, as per the Drawings nr UB-PA-A202, UB-PA-A801 and Specification).

Unglazed ceramic tile flooring at toilets, level or to falls only ≤ 15 * from horizontal, fixed over cement sand screed (screed measured seaparately). Thickness, method of construction, layout and treatments, method of jointing etc, as per the Drawings nr UB-PA-A202, UB-PA-A801 and Specification).

Terrazzo tiles, level or to falls only ≤ 15 * from horizontal, fixed over 20mm mortar bed and 20mm layer sand at roof Thickness kind, quality size, method of jointing etc, as per the Drawings nr UB-PA-A202, UB-PA-A801 and Specification).

Carpet on raised floor at control and telecom room, level to falls only ≤ 15 * from horizontal, fixed over over cement sand screed (thickness, kind quality, size, method of construction, layout and treatments, method of jointing etc, as per the Drawings nr UB-PA-A202, UB-PA-A801 and Specification).

Harden concrete with water proofing at pump house, level to falls only ≤ 15 * from horizontal, fixed over over cement sand screed (thickness, kind quality, size, method of construction, layout and treatments, method of jointing etc, as per the Drawings nr UB-PA-A202, UB-PA-A801 and Specification).

Page 1493: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 478,081.00

BF 478,081.00

FINISHES (Cont'd )

Wall tiling

1 m² 89 37.00 3,293.00

Skirting

2 m 110 19.00 2,090.00

3 m 24 18.00 432.00

4 m 17 25.00 425.00

09 50 00 Ceilings

5 m² 6 38.00 228.00

6 m² 18 48.00 864.00

Glazed ceramic tile for pantry and toilet walls width > 300mm, fixed over cement sand plaster (thickness, kind, quality size, method of construction, layout and treatments, moisture resistant treatment, method of jointing etc, as per the Drawings nr UB-PA-A202, UB-PA-A801 and Specification).

As per client answer No (243) the skirting height changed to 100mm high

Terrazzo tile skirting 100mm height, vertical, fixed over cement sand plaster (thickness, kind, quality size, method of construction, layout and treatments, moisture resistant treatment, method of jointing etc, as per the Drawings nr UB-PA-A202, UB-PA-A801 and Specification).

Unglazed ceramic tile skirting 100mm height, vertical, fixed over cement sand plaster at office and pantry area ((thickness, kind, quality size, method of construction, layout and treatments, moisture resistant treatment, method of jointing etc, as per the Drawings nr UB-PA-A202, UB-PA-A801 and Specification).

Coved ceramic tile skirting 100mm height, vertical, fixed over cement sand plaster at control and telecom area (thickness, kind, quality, size, method of construction, layout and treatment, moisture resistant treatment, method of jointing, etc; as per the Drawings nr UB-PA-A202, UB-PA-A801 and Specification).

Supply and install 600mm x 600mm moisture resistant gypsum ceiling for toilets, depth of suspension 500 - 1000 mm (thickness, kind, quality, size, method of construction, layout and treatment, moisture resistant treatment, method of jointing, etc; as per the Drawings nr UB-PA-A202, UB-PA-A801 and Specification).

Supply and install 600mm x 600mm acoustic tiles on rigid suspension ceiling for control and telecom room. (thickness, of lining and method of fixing system to structure, kind, quality, size, nature of background, insulation materials etc; as per the Drawings nr UB-PA-A202, UB-PA-A801 and Specification).

Page 1494: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

09 91 00 - Painting

Wall - Painting

7 m² 978 11.00 10,758.00

CF 496,171.00

BF 496,171.00

Ceiling - Painting

1 m² 268 11.00 2,948.00

2 m² 6 11.00 66.00

Additional Items

Painting for walls, girth > 300mm, (kind, quality of materials, painted on cement plastering, preparatory works, priming coat, undercoats, finishing coat method of application,etc, as per the Drawing nr UB-PA-A202, UB-PA-A801 and Specification).

Emulsion painting on exposed for ceiling, girth ≤ 300mm, (kind, quality of materials, painted on cement plastering, preparatory works, priming coat , undercoats finishing coat, method of application, etc, as per the Drawings nr UB-PA-A202, UB-PA-A801 and Specification).

Painting for gypsum ceiling, girth ≤ 300mm, (kind, quality of materials, painting on gypsum plaster, preparatory works, priming coat , undercoats finishing coat, method of application, etc, as per the Drawings nr UB-PA-A202, UB-PA-A801 and Specification).

Page 1495: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3 The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Page 1496: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 499,185.00

BF 499,185.00

10 00 00 SPECIALTIES

10 28 00 - Toilet, Bath and Laundry Accessories

1 Paper towel dispenser (PTD) nr 1 21.00 21.00

2 Soap dispenser (SD) nr 1 22.00 22.00

3 Mixer tap for wash basin nr 1 167.00 167.00

4 Towel ring nr 1 35.00 35.00

5 Robe hook nr 1 17.00 17.00

6 Towel bar nr 1 31.00 31.00

7 Hand dryer nr 1 1155.00 1,155.00

10 44 16.13 Potable Fire Extinguishers

8 Supply & install Portable Fire Extinguisher nr 4 54.00 216.00

Supply & install Plumbing Fixtures as shown in Drawing nr UB-PA-A202, 202 and Technical Specification including all accessories, fittings, flexible connections etc.

Page 1497: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 500,849.00

BF 500,849.00

11 00 00 EQUIPMENT

11 30 00 Residential Equipment

AS PER Q&A-77 NOT INCLUDED

1 Refrigerator / Freezer nr 1IN THE SCOPE OF WORKS

11 00 00 Equipment

Additional Items

2

All Items hereunder to be described with information such as appropriate to the procurement , design supply, execution, type, kind quality, size method of fixing, specified codes of practice,etc, as per the Drawings and Specification)

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Page 1498: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836
Page 1499: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 500,849.00

BF 500,849.00

12 00 00 FURNISHING

12 00 00 FURNISHING

Additional Items

1

All Items hereunder to be described with information such as appropriate to the procurement , design supply, execution, type, kind quality, size method of fixing, specified codes of practice,etc, as per the Drawings and Specification)

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Page 1500: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 500,849.00

BF 500,849.00

21 00 00 Fire Suppression

Additional Items

1

21 05 23 General-Duty valves for water based Fire-Suppression

2 nr 1 1002.00 1,002.00

Fire protection pipe work

3 m 4 inluded in item 8 below

All Items hereunder to be described specified code of practice and regulations, kind quality, size method of fixing, finishes or surface treatments,etc, as per the Drawings nr UB-PA-F201 and Specification)

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Supply and install floor control valve assembly 50mm diameter as per the Drawing nr UB-PA-F201

Fire main pipes, 50mm dia straight.(Type, nominal size, method of jointing, spacing and method of fixing supports, etc; as per the Drawings and Specification.

Page 1501: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

4 m 3 inluded in item 8 below

5 m 4 inluded in item 8 below

6 m 13 inluded in item 8 below

7 Supply & install NOVEC 1230 nozzle nr 4 inluded in item 8 below

8 Supply & install NOVEC 1230 cylinder nr 2 44460.00 88,920.00

CF 590,771.00

Fire main pipes, 40mm dia straight.(Type, nominal size, method of jointing, spacing and method of fixing supports, etc; as per the Drawings and Specification.

Fire main pipes, 32mm dia straight.(Type, nominal size, method of jointing, spacing and method of fixing supports, etc; as per the Drawings and Specification.

Sprinkler head,, 25mm dia straight.(Type, nominal size, method of jointing, spacing and method of fixing supports, etc; as per the Drawings and Specification.

Page 1502: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

BF 590,771.00

22 00 00 - PLUMBING

22 05 23 General-Duty Valves for Plumbing Piping

8 Gate valve, 40mm diameter nr 1 49.00 49.00

9 Gate valve, 32mm diameter nr 1 34.00 34.00

10 Angle valve, 25mm diameter nr 1included in sanitaru fixture section 22400

11 Pressure reducing valve assembly nr 1 753.00 753.00

22 11 16 Domestic Water Piping

1 m 42 19.00 798.00

2 m 2 23.00 46.00

3 m 2 31.00 62.00

4 m 3 41.00 123.00

All Items hereunder to be described specified code of practice and regulations, kind quality, size method of fixing, finishes or surface treatments,etc, as per the Drawings nr UB-PA-201, 202 and Specification)

Cold water pipes 25 mm diameter, straight, ( Type, nominal size, method of jointing, spacing and method of fixing supports, etc; as per the Drawings and Specification.

Cold water pipes 32 mm diameter, straight, ( Type, nominal size, method of jointing, spacing and method of fixing supports, etc; as per the Drawings and Specification.

Cold water pipes 40 mm diameter, straight, ( Type, nominal size, method of jointing, spacing and method of fixing supports, etc; as per the Drawings and Specification.

Cold water pipes 50 mm diameter, straight, ( Type, nominal size, method of jointing, spacing and method of fixing supports, etc; as per the Drawings and Specification.

Page 1503: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 592,636.00

BF 592,636.00

22 13 16 Sanitary Waste and Vent Piping

Sanitary Pipe Works

1 m 4 29.00 116.00

2 m 27 17.00 459.00

3 m 9 12.00 108.00

Vent Pipe Works

4 m 7 12.00 84.00

22 11 23 Domestic Water Pumps

5 nr 3 22583.00 67,749.00

Waste water pipes 110 mm diameter, straight, ( Type, nominal size, method of jointing, spacing and method of fixing supports, etc; as per the Drawings and Specification.

Waste water pipes 75 mm diameter, straight, ( Type, nominal size, method of jointing, spacing and method of fixing supports, etc; as per the Drawings and Specification.

Waste water pipes 50 mm diameter, straight, ( Type, nominal size, method of jointing, spacing and method of fixing supports, etc; as per the Drawings and Specification.

Vent pipes 50 mm diameter, straight, ( Type, nominal size, method of jointing, spacing and method of fixing supports, etc; as per the Drawings and Specification.

Supply, install, test and commission horizontal split case centrifugal pumps (2 duty + 1 standby), 32 L/S flow, 52m head, 23 kw for domestic water pumping system for operational and fuctional installation as per the Drawing nr RGC_DW_C754 and equipment schedule and Specification.

Page 1504: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

22 14 29 Submersible Sump Pumps

6 nr 2 6160.00 12,320.00

7 nr 2 6160.00 12,320.00

8 nr 1 4930.00 4,930.00

CF 690,722.00

BF 690,722.00

Fire water pumps

1 nr 2 125017.00 250,034.00

Supply, install, test and commission submersible pumps for sump pump (1 duty + 1 standby), 10 L/S flow, 10m head, 3 kw for domestic water pumping system for operational and fuctional installation as per the Drawing nr RGC_DW_C754 and equipment schedule and Specification.

Supply, install, test and commission submersible pumps for washing pump (1 duty + 1 standby), 10 L/S flow, 10m head, 3 kw for domestic water pumping system for operational and fuctional installation as per the Drawing nr RGC_DW_C754 and equipment schedule and Specification.

Supply, install, test and commission domestic water jockey pumps 6.4 L/S flow, 52m head, 5 kw for domestic water pumping system for operational and fuctional installation as per the Drawing nr RGC_DW_C754 and equipment schedule and Specification.

Supply, install, test and commission horizontal split case centrifugal pumps (1 duty + 1 standby), 126 L/S flow, 120m head, 201 kw for water domestic water pumping system for operational and fuctional installation as per the Drawing nr RGC_DW_C754 and equipment schedule and Specification.

Page 1505: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2 nr 1 included in item 1 above

3 Item 1 4130.00 4,130.00

4 Item 1 2891.00 2,891.00

5 Ea 2 9188.00 18,376.00

Additional Items

6

Supply, install, test and commission fire water jockey pumps 12.6 L/S flow, 120m head, 21 kw for fire water at domestic water pumping system for operational and fuctional installation as per the Drawing nr RGC_DW_C754 and equipment schedule and Specification.

Supply, installing, testing, commissioning, adjusting, balancing, and guarantee including operation, maintenance, tools & spare parts, all Mechanical fittings including but not limited to piping works inside the pump station, valves tees, flanges, elbows, joints, air vent pipes, pressure gauges, pressure switches flow switches, balancing valves, flexible connectionsn rubber isolators, concrete bases, control panel, electrical connections, fittings, and all necessary to complete the works as per the drawings and specification and Engineer's instructions.

Supply, installing, testing, commissioning, adjusting, balancing, and guarantee including operation, maintenance, tools & spare parts, all Mechanical fittings including but not limited to piping works for surge tank for water hammer arrest system as per the drawings, and specification and Engineer's instructions.

Supply, install, test commission flow meter supplied with isolating valves and 16 bars pressure, and but limited to including all parts coupling, valves accessoriesand marker posts on water mains with 300 mm diameter as per the drawings, and specification as indicated NWC water networks specification 4.04

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Page 1506: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 966,153.00

BF 966,153.00

PLUMBING ( Cont'd )

22 13 19.13 Sanitary Drains

1 m 4 29.00 116.00

2 m 2 12.00 24.00

Condensate Drain Pipe Works

3 m 29 9.00 261.00

4 m 25 11.00 275.00

22 33 00 Electric Domestic Water Heaters

5 nr 2 278.00 556.00

22 40 00 Plumbing Fixtures

Soil pipes 110 mm diameter, straight, ( Type, nominal size, method of jointing, spacing and method of fixing supports, etc; as per the Drawings and Specification.

Soil pipes 50 mm diameter, straight, ( Type, nominal size, method of jointing, spacing and method of fixing supports, etc; as per the Drawings and Specification.

Condensate drain pipes 20 mm diameter, straight ( Type, nominal size, method of jointing, spacing and method of fixing supports, etc; as per the Drawings and Specification.

Condensate drain pipes 25 mm diameter, straight ( Type, nominal size, method of jointing, spacing and method of fixing supports, etc; as per the Drawings and Specification.

Supply and install electric water heaters, 30L, 1200W. 220V / 1 / 60 Item to be described with information such as appropriate to the procurement, design, supply, execution, type kind quality, size, method of fixing, specified codes of practice, etc; as per the Drawings nr UB-PA-P201, UB-PA-M201, M202 and Specification).

All Items hereunder to be described with, kind quality, size method of fixing, etc, as per the Drawings nr UB-PA-201, and Specification)

Page 1507: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

6 Floor Drain (FD) and trap 75mm nr 3 193.00 579.00

7 Flexible Shower Hose nr 1 39.00 39.00

8 Water closet nr 1 316.00 316.00

9 Floor clean out 75 mm nr 1 204.00 204.00

10 Roof drain nr 4 173.00 692.00

11 Vent cap 50mm dia nr 1 44.00 44.00

CF 969,259.00

BF 969,259.00

PLUMBING ( Cont'd )

1 Urinal nr 1 461.00 461.00

2 Wash basin (WB) nr 1 136.00 136.00

3 Hose Bib 25mm diameter nr 4 44.00 176.00

4 Kitchen sink nr 1 191.00 191.00

Page 1508: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Additional Items

5 The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Page 1509: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 970,223.00

BF 970,223.00

23 07 13 Duct Insulations

1 m² 80 52.00 4,160.00

23 31 00 HVAC Ducts and Casing

2 Fresh air duct 24 gauge m² 74 66.00 4,884.00

3 Fresh air duct 26 gauge m² 6 66.00 396.00

23 33 13.13 Volume-Control Dampers

4 Volume Control Dampers 600mm x 200mm (VCD) nr 8 81.00 648.00

23 33 13.16 Fire Dampers

5 Motorized Fire Dampers (MFD) nr 3 635.00 1,905.00

23 00 00 - HEATING, VENTILATING, AND AIR CONDITONING (HVAC)

All HVAC works shall be completed as per the Drawings and Specification

All Items hereunder to be described with in type, kind quality, thickness,method of fixing, specified codes of practice,etc, as per the Drawings and Specification)

Ductwork Insulations including fixing accessories as per the Drawing nr UB-PA-M201, 202 and Specification.

All Items hereunder to be described with in type, kind quality, thickness,method of fixing, specified codes of practice,etc, as per the Drawings and Specification)

All items hereunder to be described with, type kind,quality,size, method of fixing,specified codes of practice,etc,as per the Drawings and Specification

All items hereunder to be described with, type kind,quality,size, method of fixing,specified codes of practice,etc,as per the Drawings and Specification

Page 1510: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 982,216.00

BF 982,216.00

23 34 00 HVAC Fans

1 nr 2 2708.00 5,416.00

2 nr 2 3481.00 6,962.00

3 Exhaust fan: 100 L/S, O.1 Kw, 220/1/60 wall mounted nr 3 480.00 1,440.00

All items hereunder to be described with,information such as appropriate to the procurement, capacity design supply, execution type kind,quality,size, method of fixing,specified codes of practice,etc,as per the Drawings UB-PA-M201 and Specification

Fresh air fan 1250L/S, 1.5 kw, 400/3/60, base mounted centrifugal fan ( FAF 01 & FAF 02)

Exhaust Fan: 1800/3600 L/S, 2.OKW, 400/3/60 Roof mounted up blast dual speed

Page 1511: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

4 Exhaust fan: 70 L/S, O.08 Kw, 220/1/60 wall mounted nr 1 480.00 480.00

5 Exhaust fan: 35 L/S, O.05 Kw, 220/1/60 wall mounted nr 1 480.00 480.00

6 Exhaust fan: 225 L/S, O.20 Kw, 220/1/60 wall mounted nr 1 491.00 491.00

23 37 00 Air outlets and inlets

7 600 x 200mm Fresh air grille nr 8 64.00 512.00

All items hereunder to be described with, information such as type kind,quality,size, method of fixing,specified codes of practice,etc,as per the Drawings and Specification

Page 1512: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 997,997.00

BF 997,997.00

23 82 00 Convection Heating and Cooling Units

1 nr 1 1843.00 1,843.00

2 nr 1 1843.00 1,843.00

3 nr 1 1641.00 1,641.00

4 nr 1 1191.00 1,191.00

23 05 93 Testing, Adjusting and Balancing for HVAC

5 Air balancing of the ducting network Item 1 207.00 207.00

6 Testing, balancing and commissioning of all the equipments Item 1 207.00 207.00

Additional Items

7

7.1 Building Management System Item 1 141800.00 141,800.00

All items hereunder to be described with,information such as appropriate to the procurement, capacity design supply, execution type kind,quality,size, method of fixing,specified codes of practice,etc,as per the Drawings UB-PA-M201 and Specification

Supply and install FCU/ACCU: 500L/s, 4.5Kw, 220/1/60, 5.0Kw total load, HI wall deco split.

Supply and install FCU/ACCU: 540L/s, 4.5Kw, 220/1/60, 5.4Kw total load, HI wall deco split.

Supply and install FCU/ACCU: 330L/s, 4.5Kw, 220/1/60, 3.4Kw total load, HI wall deco split.

Supply and install FCU/ACCU: 200L/s, 3.5Kw, 220/1/60, 2.1Kw total load, HI wall deco split.

All items hereunder to be described with, information such as type kind,quality,size, method of fixing,specified codes of practice,etc,as per the Drawings and Specification

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Page 1513: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 1,146,729.00

BF 1,146,729.00

26 00 00 - ELECTRICAL

26 05 19 Low Voltage Electrical Power Conductors and Cables

1 Lighting circuits Item 1 3350.00 3,350.00

2 Power circuits Item 1 1895.00 1,895.00

3 Fire Alarm circuits Item 1 24.00 24.00

All works hereunder shall be completed as per the Drawings and Specification

Notwithstanding the provision of the method of measurement, conduits have been itemised and referenced to the circuit, the contractor is to make due reference to drawings nr UB-GE-EL051-01, UB-GE-EL051-02, UB-GE-EL051-03, EL101-01, EL101-02, EL201-00, EL201-01, EL201-02, EL301-00, EL301-01, EL301-02, EL302-00, EL302-01, EL302-02, EL402-00,EL402-01, EL402-02, EL501-00, EL501-01, EL501-02, EL601-00, EL601-01, EL601-02,EL602-00, EL602-01, EL602-02, EL701-00, EL701-01, EL701-02 for full details and is to allow for all cabling, juctions, flexible connections, feeder units etc; required to complete the installation in accordance with the drawings and Specification. No claim for want or lack of knowledge will be entertained.

Page 1514: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

4 Pumps circuits Item 1 333.00 333.00

5 Water heater circuits Item 1 91.00 91.00

6 Fan circuits Item 1 1815.00 1,815.00

7 HVAC control circuits Item 1 584.00 584.00

8 Lightning protection Item 1 2823.00 2,823.00

26 05 26 Grounding and Bonding for Electrical System

9 grounding system Item 1 8712.00 8,712.00

CF 1,166,356.00

BF 1,166,356.00

26 41 13.13 Lightning Protection for Buildings

All items hereunder to be described with information such as type. Number of cores, amouring and sheathings. Method of fixing, specified codes of practice, etc; as per the Drawings and Specification.

Page 1515: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1 Lightning system Item 1 1136.00 1,136.00

26 05 33.13 Conduit for Electrical System

2 Lighting circuits Item 1 2330.00 2,330.00

3 Power circuits Item 1 1600.00 1,600.00

4 Fire Alarm circuits Item 1 22.00 22.00

5 Water heaters circuits Item 1 185.00 185.00

6 Fan circuits Item 1 77.00 77.00

7 Pumps circuits Item 1 1475.00 1,475.00

8 FCU/ACU control circuits Item 1 278.00 278.00

26 05 36 Cable Trays for Electrical System

9 m 55 45.00 2,475.00

10 Ditto but 100 mm x 200mm m 15 45.00 675.00

11 Ditto but 100 mm x 300mm m 15 52.00 780.00

12 Ditto but 100 mm x 400mm m 10 65.00 650.00

All Items hereunder to be deUS Dollaribed with information such as type, kind. Method of fixing, specified codes of practice,etc; as per the Drawings and Specification).

Notwithstanding the provision of the method of measurement, conduits have been itemised and referenced to the circuit, the contractor is to make due reference to drawings nr UB-GE-EL051-01, UB-GE-EL051-02, UB-GE-EL051-03, EL101-01, EL101-02, EL201-00, EL201-01, EL201-02, EL301-00, EL301-01, EL301-02, EL302-00, EL302-01, EL302-02, EL402-00,EL402-01, EL402-02, EL501-00, EL501-01, EL501-02, EL601-00, EL601-01, EL601-02,EL602-00, EL602-01, EL602-02, EL701-00, EL701-01, EL701-02 for full details and is to allow for all cabling, juctions, flexible connections, feeder units etc; required to complete the installation in accordance with the drawings and Specification. No claim for want or lack of knowledge will be entertained.

Supply and install cable trays 100mm x 100mm galvanized including cover, mechanical supports as per the Drawing nr UB-PH-EL402-00, 402-01, 402-02 and Specification.

Page 1516: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 1,178,039.00

BF 1,178,039.00

26 24 13 Switchboards

1 Automatic transfer switch (ATS) nr 1 51666.00 51,666.00

2 Programmble logic control (PLC) nr 1INCLUDED IN MECHANICAL EQUIPMENT

3 nr 1 23440.00 23,440.00

4 nr 1 39412.00 39,412.00

26 24 16 Panel Boards

5 Motor control centre (MCC-PS) nr 1 48431.00 48,431.00

6 Main distribution board (MDB-PS) nr 1 25902.00 25,902.00

7 Lightning and power panel (LPP-UPS) nr 1 1074.00 1,074.00

8 Lightning and power panel (LPP-PS) nr 1 991.00 991.00

All Items hereunder to be deUS Dollaribed with information such as type, kind.rated, capacity, Method of fixing,cores reference to Specification, fuses, background specified codes of practice,etc; as per the Drawings and Specification).

Supply, install, test and commission capacity bank as per the drawing and Specification

Supply, install, test and commission UPS, 50KVA as per the drawing and Specification

All Items hereunder to be deUS Dollaribed with information such as type, kind.rated, capacity, Method of fixing,cores reference to Specification, fuses, background specified codes of practice,etc; as per the Drawings and Specification).

Page 1517: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

26 27 13 Electricty Metering

CF 1,368,955.00

BF 1,368,955.00

26 27 26 Wiring Devices

1 One way one gang switch 15A nr 6 10.00 60.00

All Items hereunder to be deUS Dollaribed with information such as type, kind.rated, capacity, Method of fixing,cores reference to Specification, fuses, background specified codes of practice,etc; as per the Drawings and Specification).

All Items hereunder to be described with information such as appropriate to the procurement ,capacity design supply, execution, type, kind quality, size method of fixing, specified codes of practice,etc, as per the Drawings and Specification)

Page 1518: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2 One way two gang switch 15A nr 1 12.00 12.00

3 One way one gang switch 15A nr 8 11.00 88.00

Power outlets

4 Push button for ON and Off nr 3 7.00 21.00

5 Duplex receptable outlet, 230V, 20A, normal power supply nr 30 19.00 570.00

6 nr 1 19.00 19.00

7 Duplex receptable outlet, 230V, 20A, weather proof nr 1 58.00 58.00

8 nr 6 212.00 1,272.00

9 nr 1 28.00 28.00

10 Non-fusible disconnect switch, single pole nr 4 839.00 3,356.00

11 Non-fusible disconnect switch. Three poles nr 10 697.00 6,970.00

12 Duplex receptable outlet, 230V, 20A for hand dryer nr 1 19.00 19.00

Duplex receptable outlet, 230V, 20A, connected to emergency power supply

Duplex receptable outlet, 230V, 20A,floor box, connected to emergency power supply

Water heater receptable outlet with single pole switch, 230V, 20A normal power supply with fusible fuse.

All Items hereunder to be deUS Dollaribed with information such as type, kind.rated, capacity, Method of fixing,cores reference to Specification, fuses, background specified codes of practice,etc; as per the Drawings and Specification).

Page 1519: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 1,381,428.00

BF 1,381,428.00

26 50 00 Lightning

1 nr 15 195.00 2,925.00

2 nr 8 330.00 2,640.00

3 nr 8 128.00 1,024.00

4 nr 12 213.00 2,556.00

5 nr 4 128.00 512.00

6 nr 14 410.00 5,740.00

7 nr 6 130.00 780.00

8 nr 2 210.00 420.00

All Items hereunder to be described with information such as appropriate to the procurement ,capacity design supply, execution, type, kind quality, size method of fixing, specified codes of practice,etc, as per the Drawings and Specification)

Recessed mounted ceiling indoor luminaire with diffuser sheet, 4 no. of flourescent 14W/220V/60Hz lamps, electronic ballast & clear prismatic pattern (B2 type )

Pendant mounted with a suspended rod highbay, heavy duty, indoor industrial luminaire with metal halide elliptical 250W/220V/60Hz lamps, electronic ballast, symmetrical aluminum reflector & glass protection of ip-65 (HB1 type)

Luminaire with open end wrap around diffuser. 2 no. of flourescent 36W/220V/60Hz lamps, electronic ballast & clear prismatic pattern (C2 type )

Recess mounted drawn in modular luminaire with louver and installed with 2 x 36w 18 lamp for electronic control gears, 2 no. of flourescent 36W/220v/60Hz lamps, electronic ballast (C3 type )

Surface mounted industrial flourescent luminaire with reflector and moulded diffuser cover installed with 2 x 36w 18 flourescent lamps for electronic control gears ( E1 type )

Wall mounted bulkhead outdoor landscape clear with a 100w/220/60Hz mercury vapour elliptical lamp, prismatic pattern moulded polycarbonate diffuser cover of ip-65 (BH1- type)

Direct wall mounted single face emergency exit sign, indoor luminaire with a flourescent 8W/220/60Hz lamp, electronic ballast, maintained emergency backup of 3 hours duration & opal sheet diffuser with sign ( EX type )

Recessed mounted CFL down light installed with 2 x 26w CFL for electronic control gears (G1 type )

Page 1520: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

26 00 00 - Electrical

Additional Items

9

9.1 Item 1 1944577.00 1,944,577.00

9.2 Feeder cable from Main distribution board to Distribution boards Item 1 218529.00 218,529.00

CF 3,561,131.00

BF 3,561,131.00

27 00 00 COMMUNICATIONS

Telecommunication / Low Current

STRUCTURED CABLING SYSTEM

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Central Control and Monitoring System (CCMS) (As per Q&A No.346)

All Items hereunder to be described with information such as appropriate to the procurement ,capacity design supply, execution, type, kind quality, size method of fixing, specified codes of practice,etc, as per the Drawings nr UB-PH-T201, 202 and Specification)

Page 1521: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Item 1 2639.00 2,639.00

27 21 29 Data Communivation switches and Hubs

27 21 29 Data Communivation Wireless Access Points

1 Information outlet, flush type, 1 data, 1 telephone nr 7 48.00 336.00

2 Telephone outlet, wall mounted, flush type nr 6 34.00 204.00

3 Telecom cabinet nr 1 3251.00 3,251.00

4 Card reader, smart card nr 8 235.00 1,880.00

5 Electromagnetic door latch nr 8 383.00 3,064.00

6 Magnetic door contact switch nr 9 222.00 1,998.00

7 Request to exit button nr 8 309.00 2,472.00

8 IP fixed type CCTV, wal mounted outdoor camera (weather proof) nr 4 1520.00 6,080.00

27 00 00 Communications

Additional Items

9

ADDITIONAL

9.1 Control Panel for Access Control nr 1 1779.00 1,779.00

9.2 CCTV Equipment Item 1 7424.00 7,424.00

ADDITIONAL (As per Q&A 487)9.3 nr 1 10791.00 10,791.00

Supply, install, test connect and commission inclusive of all cabling, conduits and containment, socket outlets, all in accordance with the relevant service provider regulations, rules, recommendation and requirements and in accordance with the specifications and drawings.

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

ACTIVE COMPONENTS (AS PER Q&A 487) DISTRIBUTION CABINET

Page 1522: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 3,603,049.00

BF 3,603,049.00

28 00 00 ELECTRONIC SAFETY AND SECURITY

28 31 00 Fire Detection and Alarm

1 Supply, install smoke detector nr 6 110.00 660.00

2 Supply, install heat detector nr 1 104.00 104.00

3 Multisensor detector nr 1 139.00 139.00

4 Smoke detector, beam type-transceiver nr 1 1204.00 1,204.00

5 Manual pull station - 1.2 meters from FFL to the centre of the device. nr 5 110.00 550.00

6 Horn strobe, top even with the top of door bucks nr 2 185.00 370.00

7 nr 3 123.00 369.00

8 Fault isolator - ceiling mounted or as per site situation nr 2 110.00 220.00

9 nr 14 110.00 1,540.00

10 Fire alarm control panel nr 1 8444.00 8,444.00

11 Power supply unit, 24V nr 1 included in the above

28 00 00 Electronic Safety and Security

Additional Items

All Items hereunder to be described with information such as appropriate to the procurement ,type, kind quality, size method of fixing, specified codes of practice,etc, as per the Drawings and Specification)

Sounder/fire alarm bell/horn - 0.30 meters below from ceiling line to the centre of the device.

Control module - 0.20 meters below from ceiling line to the centre of the device

Page 1523: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

12

CF 3,616,649.00

BF 3,616,649.00

31 00 00 EARTHWORK

31 10 00 Site Cearing

1 Site preparation, clearing site vegetation m² 322 2.00 644.00

31 23 16 Excavation

2 Excavating top soil for preservation, average depth 150mm m² 322 3.00 966.00

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

All works herein shall be comnpleted in full compliance with the Drawings nr UB-PA-S101, UB-PA-S201, UB-PA-S202, UB-PA-401, UB-PA-S402 and Specification

Page 1524: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

3 Excavating pits depth of excavation not exceeding 2 m m³ 290 8.00 2,320.00

4 Excavating pits depth of excavation from 2-4m m³ 290 8.00 2,320.00

5 Excavating pits depth of excavation from 4-6m m³ 232 8.00 1,856.00

6 Excavating pits (11 nr) maximum depth ≤ 2.00 m m³ 89 8.00 712.00

7 Excavating trenches for grade beams, width s.0.5m m³ 16 10.00 160.00

31 23 23.13 BACKFILL

8 m³ 60 12.00 720.00

31 23 23.23 Compaction

9 m² 410 3.00 1,230.00

10 Disposal of excavated material, off site as stated in the Specification m³ 753 4.00 3,012.00

Filling to excavation, average thickness > 0.25 m, arising from excavated materials, all fill shall be compacted to 75% relative density for cohesion-less soils as per ASTM D4254/ASTM D4293 or 95% maximum density as determined by ASTM D698 for cohesive materials

Surface treatment, compacting bottom of excavation, compaction to meet 85% of relative density for cohesion-less or 95% maximum density as determined by ASTM D1557 for cohesive materials per the Drawings and Specification).

Page 1525: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 3,630,589.00

BF 3,630,589.00

31 31 16 Termite Control

1 m² 410 1.00 410.00

2 m² 450 0.00 0.00

Additional Items

33 00 00 UTILITIES

3 nr 1 0.00 0.00

Additional Items

41 22 00 Cranes and Hoists

4 nr 1 49797.00 49,797.00

Additional Items

5

Termite control for the horizontal surface (method and type of treatment as per the Drawings and Specification).

Termite control for the vertical surface (method and type of treatment as per the Drawings and Specification).

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Suppply and install water meter as per the Drawings nr and Specification

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Supply and install Electrical Overhead transfer Crane ( Single ginder ) as per the Drawings Number and Specification.

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included.

Page 1526: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for DOMESTIC AND FIRE WATER - PUMP HOUSE AND ANNEX

CARRIED TO SUMMARY US Dollar. 3,680,796.00

DOMESTIC AND FIRE WATER - TRANSFORMER ROOM

03 00 00 - CONCRETE

Notwithstanding the Provisions of the Standard Method of Measurement of Building Works Seventh Edition, 1988 (SMM7) the following,concrete works are measured m³/m including. reinforcement bars and formworks. The Contractor is to include for cost of reinforcement and formwork with concrete works. No additional charge or cost for reinforcement and formwork separately will be entertained due to lack or want of knowledge.

All concrete works herein shall be completed in full compliance with the Drawings nr UB-TR2-S101 and Specification

Page 1527: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

03 11 13 Structural Cast-in Place Concrete Forming

1 m³ 0.25 188.00 47.00

03 31 00 Structural Concrete

2 m³ 1 468.00 468.00

3 m³ 4 942.00 3,768.00

4 m³ 5 366.00 1,830.00

5 m³ 0.25 571.00 142.75

6 m³ 10 647.00 6,470.00

7 m³ 4 1064.00 4,256.00

8 m³ 1 1153.00 1,153.00

9 m³ 2 904.00 1,808.00

Plain Concrete 20 MPa, for blinding Beds, Thickness ≤ 150mm. Poured againts the compacted soil, as the Structural Notes and Specification.

Reinforced concrete 35 Mpa, foundations ( footings):kind,quality, curing details etc. as stated in the Structural Notes and Specification.

Reinforced concrete 35 Mpa for ground beams; kind,quality, curing details etc. as stated in the Structural Notes and Specification.as stated in the Structural Notes and Specification.

Reinfoced concrete beds 35 Mpa for slab with A393 welded wire mesh, on grade; 150mm thick poured againts the compacted soil including cable trench kind quality, curing details etc.as stated in the Structural Notes and Specification.

Reinforced concrete for substructure columns 35 Mpa up to slab on grade; kind quality, curing details etc.as stated in the Structural

Reinforced concrete 35 Mpa for substructure slab, thickness 150mm (kind quality, curing details etc.as stated in the Structural Notes and Specification.

Reinforced concrete 35 Mpa for super structure beams, (kind,quality, curing details etc. as stated in the Structural Notes and Specification.

Reinforced concrete 35 Mpa for super structure columns, (kind,quality, curing details etc. as stated in the Structural Notes and Specification.

Reinforced concrete 35 Mpa for super structure parapet, (kind,quality, curing details etc. as stated in the Structural Notes and Specification.

Page 1528: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 19,942.75

BF 19,942.75

03 30 53 - Miscellaneous Cast-in-situ Concrete

1 200mm wide x 200mm high reinforced concrete 35 Mpa for lintel m 10 21.00 210.00

03 53 00 Concrete Topping

2 m² 40 17.00 680.00

3 m² 44 44.00 1,936.00

03 00 00 - CONCRETE

4

Sand cement/concrete screed for floors, width > 300mm, (thickness,kind quality,composition mix, nature of base method of construction. Layout and treatments,thermal insulation,moisture resistant treatment method of jointing, etc, as per the Drawings and Specification).

Sand cement/concrete screed for roof with A 393, width > 300mm, (thickness,kind quality,composition mix, nature of base method of construction. Layout and treatments,thermal insulation,moisture resistant treatment method of jointing, etc, as per the Drawings and Specification).

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included

Page 1529: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 22,768.75

BF 22,768.75

04 00 00 - Masonry

04 22 00 - Concrete Unit Masonry

External walls

1 m² 57 39.00 2,223.00

04 00 00 - Masonry

Additional Items

All Masonry works herein shall be completed full incompliance with the Drawings nr UB-TR-S101, UB-TR-A207, UB-TR-A507, UB-TR-A805 and Specification.

200mm thick CMU wall, external vertical block work, (kind, quality and size of blocks,; type of bond, mix of motar etc. to be included as per the Specification).

Page 1530: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2 The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included

Page 1531: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 24,991.75

BF 24,991.75

07 00 00 THERMAL AND MOISTURE PROTECTION

07 10 00 Damp proofing and Waterproofing

Substructure Waterproofing

1 m² 7 5.00 35.00

2 m² 49 2.00 98.00

3 m² 24 31.00 744.00

Wet Area Waterproofing / Roof Waterproofing

4 m² 40 43.00 1,720.00

5 m² 40 23.00 920.00

Additional Items

6

6.1 m² 8 5.00 40.00

All works herein shall be completed in full compliance with the Drawings nr UB-TR-S101, UB-TR-A207, UB-TR-A507, UB-TR-A707, UB-TR-A805 and Specification.

Waterproofing works for substructure with two coast of bitumen paint, vertical surface, as per the Drawings and Specification)

Waterproofing works for substructure with vapour barrier 250 microns, horizontal surface, as per the Drawings and Specification)

Waterproofing works for substructure with mastic sealant, vertical surface as per the Drawings and Specification)

All works herein shall be completed in full compliance with the Drawings nr UB-TR-S101, UB-TR-A207 and Specification)

Waterproofing membrane with geotextile layer on top for roof horizontal surface as per the Drawings and Specification)

100mm thick rigid insulation for water proofing works at roof, horizontal surface, as per the Drawings and Specification)

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included

Waterproofing works for substructure with two coast of bitumen paint, horizontal surface, width > 300mm (kind, quality, method of application, thickness as per the Drawings and Specification)

Page 1532: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 28,548.75

BF 28,548.75

08 00 00 - OPENINGS

Note

08 11 00 - Metal Doors

1 nr 1 3317.00 3,317.00

08 51 13 Aluminum Windows

All works herein shall be completed in full compliance with the Doors & Windows schedule Drawings nr UB-TR-S101, UB-TR-A207, UB-TR-A507, UB-TR-A707, UB-TR-A805 and Specification.

Notwithstanding the Provisions of the Standard Method of Measurement, doors, frames, vision panels, decoration and ironmongery have been measured including. reinforcement bars and formworks. The Contractor is to include for cost of reinforcement and formwork with concrete works. No additional charge or cost for reinforcement and formwork separately will be entertained due to lack or want of knowledge.

Supply and fix steel door, 3000mm wide x 2200mm high with including hollow metal frame, type D1, including paint, all accessories and hardware including but not limited hinges HDH type, SST outside and door lock with adjustable hydraulic closing back check and latching control, lever handles and latch, wall stop with roses and escutcheons as stated in the Drawing Specification.

Page 1533: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2 nr 3 1718.00 5,154.00

08 00 00 OPENINGS

Additional Items

3

CF 37,019.75

BF 37,019.75

Supply and fix aluminium window, 1600mm wide x 1600mm high, including frame, type W1, finished powder coated, all accessories and hardware including but not limited to hinges, handle, lock, weather tight strip etc. as stated in the Drawings and Specification.

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included

Page 1534: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

09 00 00 - FINISHES

09 24 00 Cement Plastering

1 m² 55 22.00 1,210.00

External Walls

2 m² 59 29.00 1,711.00

3 m² 30 29.00 870.00

09 30 13 Ceramic Tiling

Floor Tilling

4 m² 34 33.00 1,122.00

Skirting

5 m 21 19.00 399.00

All works herein shall be completed in full compliance with the schedule Drawings nr UB-TR-S101, UB-TR-A207, UB-TR-A507, UB-TR-A707, UB-TR-A805 and Specification.

Plastering for internal walls to receive paint finish, width > 300mm, (thickness, kind quality, composition, mix materials, nature of base, method of construction layout and treatment, thermal insulation, moisture resistant treatment, method of jointing etc, as per the Drawings nr UB-TR-A207, UB-TR-A507, UB-TR-A707 and Specification).

Self coloured rendering ( pre coloured mineral wall coating ) for external walls width > 300mm, (thickness, kind quality, composition, mix materials, nature of base, method of construction layout and treatment, thermal insulation, moisture resistant treatment, method of jointing etc, as per the Drawings nr UB-TR-A207, UB-TR-A507, UB-TR-A707 and Specification).

Self coloured rendering ( pre coloured mineral wall coating ) for parapet at roof area width > 300mm, (thickness, kind quality, composition, mix materials, nature of base, method of construction layout and treatment, thermal insulation, moisture resistant treatment, method of jointing etc, as per the Drawings nr UB-TR-A207, UB-TR-A507, UB-TR-A707 and Specification).

Terrazzo tile flooring, level or to falls only ≤ 15 * from horizontal, fixed over cement sand screed ( screed measured separately ) thickness, method of construction layout and treatment, method of jointing etc, as per the Drawings nr UB-TR-A207, UB-TR-A507, UB-TR-A707 and Specification).

Terrazzo tile skirting 150mm height, vertical, fixed over cement sand plaster (thickness , kind, quality, size,nature of base, method of construction, layout and treatments,thermal insulation, moisture resistant treatment, method of jointing, etc, as per the Drawings nr UB-TR-A207, UB-TR-A507, UB-TR-A707 and Specification).

Page 1535: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 42,331.75

BF 42,331.75

09 50 00 Ceilings

Ceiling-Painting

1 m² 34 11.00 374.00

09 91 00 - Painting

Wall - Painting

2 m² 55 11.00 605.00

09 00 00 FINISHES

Additional Items

3

Emulsion Painting on exposed for ceiling, girth ≤ 300mm, ( kind, quality, of materials, painted on cement plaster, preparatory works, priming coat, undercoats, finishing coat method of application etc; as per the Drawings and Specification).

Painting for walls internal surface, girth > 300mm, (kind, quality of materials, painted on cement plastering, preparatory works, priming coat, undercoats, finishing coat method of application,etc, as per the Drawing and Specification.

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included

Page 1536: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 43,310.75

BF 43,310.75

21 00 00 Fire Suppression

Page 1537: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Additional Items

1

21 13 26 Deluge Fire-Suppression Sprinkler System

2 Item 1 36094.00 36,094.00

Fire Protection Pipe Works

3 m 7 38.00 266.00

4 m 2 30.00 60.00

5 m 5 26.00 130.00

6 m 9 22.00 198.00

7 nr 6included in item 2 abbove

All Items hereunder to be described specified code of practice and regulations, kind quality, size method of fixing, finishes or surface treatments,etc, as per the Drawings nr UB-TR-M201, M202 and Specification)

The Contractor is to list here any price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here .Any such items not listed below shall be deemed to be included. and complete and fuctional operation.

Supply and install DELUGE system as per the Drawing nr UB-TR-M201

Fire water pipes, 50mm dia straight, (Type, nominal size, method of jpinting, spacing and method of fixing supports, etc; as per the Drawing and Specification.

Fire water pipes, 40mm dia straight, (Type, nominal size, method of jpinting, spacing and method of fixing supports, etc; as per the Drawing and Specification.

Fire water pipes, 32mm dia straight, (Type, nominal size, method of jpinting, spacing and method of fixing supports, etc; as per the Drawing and Specification.

Fire water pipes, 25mm dia straight, (Type, nominal size, method of jpinting, spacing and method of fixing supports, etc; as per the Drawing and Specification.

Supply and fix open sprinkler head (Type, nominal size, method of jpinting, spacing and method of fixing supports, etc; as per the Drawing and Specification.

Page 1538: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 80,058.75

BF 80,058.75

22 00 00 - PLUMBING

22 13 16 Sanitary Waste and Vent Piping

Rain Water Pipe Works

1 m 7 17.00 119.00

22 40 00 Plumbing Fixtures

2 Roof drain (75 dia) nr 2 173.00 346.00

Additional Items

3

All Items hereunder to be described specified code of practice and regulations, kind quality, size method of fixing, finishes or surface treatments,etc, as per the Drawings nr UB-TR-M201,and Specification)

Rain water pipes 75 mm diameter, straight,(Type, nominal size, method of jpinting, spacing and method of fixing supports, etc; as per the Drawing and Specification.

All items hereunder to be described with, kind quality, size nature of base method of fixing, etc; as per the Drawings nr UB-TR-M202 and Specification.

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included.

Page 1539: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 80,523.75

BF 80,523.75

23 00 00 - HEATING, VENTILATING, AND AIR CONDITIONING (HVAC)

All HVAC works shall be completed as per the Drawings and Specification

Page 1540: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

23 34 00 HVAC Fans

1 Exhaust Fan: 125 L/S. 0.03KW 220/1/60Hz wall mounted nr 2 480.00 960.00

Additional Items

2

All Items hereunder to be described with information such as approriate to the procurement, capacity design, supply, execution type, kind quality,size, method of fixing, specified codes of practice,etc, as per the Drawings and Specification)

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included.

Page 1541: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 81,483.75

BF 81,483.75

26 00 00 - ELECTRICAL

26 12 00 Medium-Voltage Transformers

1 Included Electrical power B0Q

26 05 26 Grounding and Bonding for Electrical System

2 Grounding system Item 1 1757.00 1,757.00

26 41 13.13 Lightning Protection for Buildings

3 Lightning system Item 1As per Q&A # 374 - Not Required

26 27 26 Wiring Devices

4 One way two gang switch. 15A nr 1 10.00 10.00

All works hereunder shall be completed as per the Drawings nr UB-TR-EL801-00 and Specification

Supply, installation, testing, commissioning, adjusting, balancing, package transformer 1000KVA and guarantee including operation, maintenance, and all electrical fittings including but not limited to cabling as per the drawings, specification and Engineer's instruction.

All Items hereunder to be described with information such as type, kind number of cores, armouring and sheating, method of fixing, specified codes of practice,etc, as per the Drawings and Specification)

All Items hereunder to be described with information such as approriate to the procurement, type, kind quality,size, method of fixing, specified codes of practice,etc, as per the Drawings and Specification)

Page 1542: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Power Outlets

5 Duplex receptable outlet, 230V, 20A normal power supply nr 2 19.00 38.00

CF 83,288.75

BF 83,288.75

26 50 00 lighting

1 nr 4 128.00 512.00

All Items hereunder to be described with information such as appropriate to the procurement , type, kind quality, size method of fixing, specified codes of practice,etc, as per the Drawings nr UB-TR-EL801-00 and Specification)

Direct surface mounted (ceiling mounted) with open end wrap around diffuser, 2 no. of flourescent 36w/220V/60Hz lamps, electronic ballast & clear prismatic pattern (C2 type)

Page 1543: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2 nr 2 1485.00 2,970.00

26 00 00 - Electrical

Additional Items

3

Wall mounted bulkhead outdoor and landscape clear with a 100W/220V/60Hz mercury vapour elliptical lamp, prismatic pattern moulded polycarbonate diffuser cover of ip-65 (BH2 )

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included.

Page 1544: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 86,770.75

BF 86,770.75

27 00 00 COMMUNICATIONS

27 16 13 Communication Custom Cable Assemblies

1 Loop cables, 2 x 1.5 mm2 (Fire resistant cable ) m 5 9.00 45.00

27 21 29 Data Communication switches and Hubs

27 21 29 Data Communication Wireless Access Points

2 Information outlet, flush type, 1 data, 1 telephone nr 1 48.00 48.00

3 IP fixed type CCTV, wall mounted outdoor camera (weather proof) nr 1 1520.00 1,520.00

4 Card reader, smart card nr 1 235.00 235.00

5 Electromagnetic door latch nr 1 383.00 383.00

6 Magnetic door contacts switch nr 1 222.00 222.00

7 Request to exit button nr 1 309.00 309.00

8 Pull box nr 1 110.00 110.00

27 00 00 Communications

Additional Items

9

All Items hereunder to be described with information such as appropriate to the procurement , type, kind quality, size method of fixing, specified codes of practice,etc, as per the Drawings nr UB-GH & TR-T201, T301 and Specification)

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included.

Page 1545: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

ADDITIONAL

9.1 Control Panel for Access Control nr 1 1779.00 1,779.00

CF 91,421.75

BF 91,421.75

28 00 00 ELECTRONIC SAFETY AND SECURITY

28 31 00 Fire Detection and Alarm

1 Supply, install smoke detector nr 1 69.00 69.00

2 Supply, install smoke and heat detector nr 1 98.00 98.00

3 Multisensor detector nr 1 98.00 98.00

All Items hereunder to be described with information such as appropriate to the procurement , type, kind quality, size method of fixing, specified codes of practice,etc, as per the Drawings and Specification)

Page 1546: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

4 Manual pull station - 1.2 meters from FFL to the centre of the device nr 1 69.00 69.00

5 nr 1 81.00 81.00

6 Fault isolator - ceiling mounted or as per site situation. nr 1 77.00 77.00

7 nr 1 69.00 69.00

28 00 00 Electronic Safety and Security

Additional Items

8

Sounder/fire alarm bell/horn - 0.30 meters below from ceiling line to the centre of the device.

Control module - 0.20 meters below from ceiling line to the centre of the device.

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included.

Page 1547: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 91,982.75

BF 91,982.75

31 00 00 EARTHWORK

1 Site preparation, clearing site vegetation m² 54 2.00 108.00

31 23 16 Excavation

2 Excavation top soil for preservation, average depth 150mm m² 54 3.00 162.00

3 Excavating pits depth excavation not exceeding 2m m³ 19 8.00 152.00

31 23 16 Backfill

4 m³ 14 12.00 168.00

31 23 23.23 Compaction

5 m² 45 3.00 135.00

31 23 16.26 Rock Removal

6 Disposal of excavated material, off site as stated in the Specification. m³ 5 4.00 20.00

31 31 16 Termite Control

7 m² 45 1.00 45.00

8 m² 50 0.00 0.00

All works herein shall be comnpleted in full compliance with the Drawings nr UB-TR2-S101 and Specification.

Filling to excavation, average thickness > 0.25 m, arising from excavated materials, all fill shall be compacted to 75% relative density for cohesion-less soils as per ASTM D4254/ASTM D4293 or 95% maximum density as determined by ASTM D698 for cohesive materials

Surface treatment, compacting bottom of excavation, compaction to meet 85% of relative density for cohesion-less or 95% maximum density as determined by ASTM D1557 for cohesive materials per the Drawings and Specification).

Termite control for the horizontal surface ( method and type of treatment and compactions to be started as per the Drawings and Specification.

Termite control for the vertical surface ( method and type of treatment and compactions to be started as per the Drawings and Specification.

Page 1548: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 92,772.75

BF 92,772.75

31 00 00 EARTHWORK

Additional Items

1 The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included.

Page 1549: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836
Page 1550: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CARRIED TO SUMMARY US Dollar 92,772.75

DOMESTIC AND FIRE WATER - GENERATOR ROOM

03 00 00 - CONCRETE

03 11 13 Structural Cast-in Place Concrete Forming

1 m³ 5 188.00 940.00

03 31 00 Structural Concrete

2 m³ 10 521.00 5,210.00

3 m³ 5 399.00 1,995.00

4 m³ 12 653.00 7,836.00

5 m³ 3 789.00 2,367.00

6 m³ 1 436.00 436.00

7 m³ 2 863.00 1,726.00

Total for DOMESTIC AND FIRE WATER - TRANSFORMER ROOM

Notwithstanding the Provisions of the Standard Method of Measurement of Building Works Seventh Edition, 1988 (SMM7) the following,concrete works are measured m³/m including. reinforcement bars and formworks. The Contractor is to include for cost of reinforcement and formwork with concrete works. No additional charge or cost for reinforcement and formwork separately will be entertained due to lack or want of knowledge.

All concrete works herein shall be completed in full compliance with the Drawings nr UB-GR-S101, UB-GR-S401 and Specification.

Plain Concrete, 20 Mpa, for blinding Beds, Thickness ≤ 150mm. Poured againts the compacted soil, as the Structural Notes and Specification.

Reinforced concrete 35 Mpa, foundations ( footings):kind,quality, curing details etc. as stated in the Structural Notes and Specification.

Reinforced concrete 35 Mpa foundation (Raft), 300mm thick including sump pit at fuel tank, kind,quality, curing details etc. as stated in the Structural Notes and Specification.

Reinforced concrete 35 Mpa substructure walls 300mm width: kind quality, curing details etc.as stated in the Structural Notes and Specification.

Reinforced concrete 35 Mpa substructure trech walls 200mm width: kind quality, curing details etc.as stated in the Structural Notes and Specification.

Reinforced concrete 35 Mpa substructure trech slab 200mm width: kind quality, curing details etc.as stated in the Structural Notes and Specification.

Reinforced concrete 35 Mpa for ground beams; kind,quality, curing details etc. as stated in the Structural Notes and Specification.

Page 1551: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

8 m³ 8 512.00 4,096.00

CF 24,606.00

BF 24,606.00

CONCRETE (Cont'd )

1 m³ 1 959.00 959.00

2 m³ 9 650.00 5,850.00

3 m³ 3 983.00 2,949.00

4 m³ 2 904.00 1,808.00

5 m³ 6 1483.00 8,898.00

Reinfoced concrete beds 35 Mpa for slab with A393 welded wire mesh, on grade; thickness ≤ 150mm, poured againts the compacted soil kind quality, curing details etc.as stated in the Structural Notes and Specification.

Reinforced concrete substructure columns 35 Mpa up to slab on grade: kind quality, curing details etc.as stated in the Structural Notes and Specification.

Reinforced concrete 35 Mpa substructure slab, thickness 200mm, (kind quality, curing details etc.as stated in the Structural Notes and Specification.

Reinforced concrete 35 Mpa superstructure for roof beams; kind,quality, curing details etc. as stated in the Structural Notes and Specification.

Reinforced concrete 35 Mpa superstructure for parapet walls on roof 200mm thickness; kind,quality, curing details etc. as stated in the Structural Notes and Specification.

Reinforced concrete 35 Mpa superstructure columns, (kind,quality, curing details etc. as stated in the Structural Notes and Specification.

Page 1552: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

6 m³ 3 394.00 1,182.00

7 nr 3 349.00 1,047.00

03 41 00 Precast Structural Concrete

8 m² 12 135.00 1,620.00

03 30 53 - Miscellaneous Cast-in-situ Concrete

9 200mm wide x 200mm high reinforced concrete 35 Mpa for lintel m 9 21.00 189.00

Reinforced concrete 35 Mpa platform pad, thickness 400mm at generator room, (kind,quality, curing details etc. as stated in the Structural Notes and Specification.

Reinforced concrete 35 Mpa for saddle support at diesel tank, (kind,quality, curing details etc. as stated in the Structural Notes and Specification.

Reinforced precast concrete cover slab, 200mm thickness at diesel tank, (kind,quality, curing details etc. as stated in the Structural Notes and Specification.

Page 1553: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 49,108.00

BF 49,108.00

CONCRETE (Cont'd )

03 53 00 Concrete Topping

1 m² 23 17.00 391.00

2 m² 41 22.00 902.00

03 00 00 - CONCRETE

Additional Items

3

Sand cement/concrete screed for protection screed for substructure, width > 300mm,50mm thick (thickness,kind quality,composition mix,material nature of base method of construction. Layout and treatments,thermal insulation,moisture resistant treatment method of jointing, etc, as per the Drawings and Specification).

Sand cement/concrete screed for roof, width > 300mm, (thickness,kind quality,composition mix,material nature of base method of construction. Layout and treatments,thermal insulation,moisture resistant treatment method of jointing, etc, as per the Drawings and Specification).

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included.

Page 1554: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 50,401.00

BF 50,401.00

04 00 00 - Masonry

04 22 00 - Concrete Unit Masonry

External Walls

1 m² 141 39.00 5,499.00

04 00 00 - MASONRY

Additional Items

2

All Masonry works herein shall be completed full incompliance with the Drawings nr UB-GEH-A205, UB-GEH-A505, UB-GEH-A705, UB-GEH-A803 and Specification.

200mm thick CMU wall, external vertical block work, (kind, quality and size of blocks,; type of bond, mix of motar etc. to be included as per the Specification).

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included.

Page 1555: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836
Page 1556: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 55,900.00

BF 55,900.00

05 00 00 - METALS

05 00 00 METALS

1 nr 9 57.00 513.00

2 nr 2 542.00 1,084.00

05 00 00 METALS

Additional Items

3

As per Question and Answer No (514)3.1 Trench cover, 610mm wide LM 4 122.00 488.00

3.2 Pit cover, 1000 x 860mm nr 1 384.00 384.00

All metals works herein shall be completed in full compliance with the Drawings nr UB-GR-S101, UB-GR-S401 and Specification.

Supply and fixed lifting hook including mechanical support as per Drawings and per Specification.

Supply and fix 500mm x 500mm heavy duty steel cover and frame in at diesel tank, kind, quality, fittings, fixtures, accessories as per Drawings and as per Specification.

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included.

Page 1557: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 58,369.00

BF 58,369.00

07 00 00 THERMAL AND MOISTURE PROTECTION

07 10 00 Damp proofing and Waterproofing

Substructure Waterproofing

1 m 16 16.00 256.00

2 m² 85 5.00 425.00

3 m² 25 5.00 125.00

4 m² 66 2.00 132.00

All works herein shall be completed in full compliance with the Drawings nr UB-GR-S101, UB-GR-S401, UB-GEH-A205, UB-GEHA505, UB-GEH-A705, UB-GEH-A803 and Specification.

Waterproofing works for substructure 250mm PVC water stop (approved). vertical surface at retaining wall, as per the Drawings and Specification)

Waterproofing works for substructure with two coast of bitumen paint, vertical surface, as per the Drawings and Specification)

Waterproofing works for substructure with two coast of bitumen paint, horizontal surface, as per the Drawings and Specification)

Waterproofing works for substructure with vapour barrier 250 microns, horizontal surface, as per the Drawings and Specification)

Page 1558: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

5 m² 46 36.00 1,656.00

6 m² 54 30.00 1,620.00

7 m² 10 30.00 300.00

8 m² 39 61.00 2,379.00

9 m 47 21.00 987.00

CF 66,249.00

BF 66,249.00

THERMAL AND MOISTURE PROTECTION (Cont'd)

Wet Area Waterproffing / Roof Waterproofing

Waterproofing works for substructure with two layer of water proofing membrane horizontal surface, as per the Drawings and Specification)

Waterproofing works for substructure with two layer of water proofing membrane vertical surface, as per the Drawings and Specification)

Waterproofing works for substructure with two layer of water proofing membrane with protection board, vertical surface trech wall, as per the Drawings and Specification)

Waterproofing mebrane with geotextile layer on top for roof, horizontal surface, as per the Drawings and Specification)

Supply and fix mastic sealant for vertical surface wide ≤ 200mm at cable trench as per the Drawing and Specification.

All works herein shall be completed in full compliance with the Drawings nr UB-GR-S101, UB-GR-S401, UB-GEH-A205, UB-GEHA505, UB-GEH-A705, UB-GEH-A803 and Specification.

Page 1559: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1 m 16 21.00 336.00

2 m² 11 62.00 682.00

3 m² 29 62.00 1,798.00

07 00 00 Thermal and Moisture Protection

Additional Items

4

Supply and fix joint sealant for vertical wide ≤ 200 mm at diesel tank as per the Drawing and Specification.

Waterproofing works, diesel resistant lining for diesel tank, horizontal surface, as per the Drawings and Specification)

Waterproofing works, diesel resistant lining for diesel tank, vertical surface, as per the Drawings and Specification)

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included.

Page 1560: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 69,065.00

BF 69,065.00

08 00 00 OPENINGS

Note

08 11 00 - Metal Doors

1 nr 1 2788.00 2,788.00

08 51 13 Aluminum Windows

2 nr 1 925.00 925.00

3 nr 1 2110.00 2,110.00

08 00 00 OPENINGS

Additional Items

All works herein shall be completed in full compliance with the Doors & Windows schedule Drawings nr UB-GR-S101, UB-GR-S401, UB-GEH-A205, UB-GEHA505, UB-GEH-A705, UB-GEH-A803 and Specification.

Notwithstanding the Provisions of the Standard Method of Measurement, doors, frames, vision panels, decoration and ironmongery have been measured including. reinforcement bars and formworks. The Contractor is to include for cost of reinforcement and formwork with concrete works. No additional charge or cost for reinforcement and formwork separately will be entertained due to lack or want of knowledge.

Supply and fix steel door, 2300mm wide x 2200mm high with including hollow metal frame, type D1, including paint all accessories and hardware including but not limited to hinges HDH type, SST outside and door lock with adjustable hyrraulic, lclosing back check and latch, wall stop with louver as stated in the Specification.

Supply and fix aluminum window, powder coated 1600mm wide x 1600mm high with including frame, type W1, with fresh air grille with sand trap louver, all accessories and hardware including but not limited to hinges handle, lock, weather tight strip etc; as stated in the Drawings and Specification.

Supply and fix aluminum window, powder coated 3650mm wide x 1600mm high including frame, type W1, with fresh air grille with sand trap louver, all accessories and hardware including but not limited to hinges handle, lock, weather tight strip etc; as stated in the Drawings and Specification.

Page 1561: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

4

CF 74,888.00

BF 74,888.00

09 00 00 - FINISHES

09 24 00 Cement Plastering

1 m² 142 22.00 3,124.00

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included.

All works herein shall be completed in full compliance with the schedule Drawings nr UB-GR-S101, UB-GR-S401, UB-GEH-A205, UB-GEHA505, UB-GEH-A705, UB-GEH-A803 and Specification.

Plastering for walls to receive paint finish, width > 300mm, (thickness, kind quality, composition, mix materials, nature of base, method of construction layout and treatment, thermal insulation, moisture resistant treatment, method of jointing and joint reinforcement etc, as per the Drawings UB-GEH-A803 and Specification).

Page 1562: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

External Walls

2 m² 145 29.00 4,205.00

3 m² 35 29.00 1,015.00

Floor Finishes

4 m² 39 48.00 1,872.00

09 91 00 - Painting

Wall - Painting

5 m² 142 11.00 1,562.00

Self coloured rendering ( pre coloured mineral wall coating ) for external walls width > 300mm, (thickness, kind quality, composition, mix materials, nature of base, method of construction layout and treatment, thermal insulation, moisture resistant treatment, method of jointing etc, as per the Drawings nr UB-GR-S101, UB-GR-S401, UB-GEH-A205, UB-GEHA505, UB-GEH-A705, UB-GEH-A803 and Specification.

Self coloured rendering ( pre coloured mineral wall coating ) for parapet walls at roof area width > 300mm, (thickness, kind quality, composition, mix materials, nature of base, method of construction layout and treatment, thermal insulation, moisture resistant treatment, method of jointing etc, as per the Drawings and Specification).

Harden concrete with water proofing at generator room, levels to falls only ≤ 15 from horizontal, fixed over cement sand screed (thickness, kind, quality, size, method of construction layout and treatment, method of jointing etc, as per the Drawings and Specification).

Painting for walls internal surface, girth > 300mm ( kind quality of material, painted on cement plastering, preparatory works, priming coat, undercoats, finishing coat method of application etc; as per the Drawings and Specification.

Page 1563: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 86,666.00

BF 86,666.00

FINISHES ( Cont'd )

Ceiling - Painting

1 m² 39 11.00 429.00

09 00 00 Finishes

Additional Items

2

Emulsion Painting on exposed for ceiling, girth ≤ 300mm, ( kind, quality, of materials, painted on cement plaster, preparatory works, priming coat, undercoats, finishing coat method of application etc; as per the Drawings and Specification).

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included.

Page 1564: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 87,095.00

BF 87,095.00

10 00 00 SPECIALTIES

10 44 13.13 Portable Fire Extinguishers

1 Supply & install Portable Fire Extinguisher, 10 Kg CO2 nr 1 272.00 272.00

21 00 00 Fire Suppression

Supply & install Plumbing Fixtures as shown in Drawing nr UB-GEH-M201 and Technical Specification including all accessories, fittings, flexible connections etc.

All Items hereunder to be described with kind, quality, size, method of fixing,etc, as per the Drawings and Specification.

Page 1565: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Additional Items

2

21 13 39 Foam-Water System

3 nr 1 37925.00 37,925.00

Fire protection pipe works

4 m 11 38.00 418.00

5 m 5 38.00 190.00

6 nr 3 38.00 114.00

All Items hereunder to be described specified code of practice and regulations, kind quality, size method of fixing, finishes or surface treatments, etc; as per the Drawings nr UB-GEH-M201 and Specification.

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included.

Supply and install foam chemical tank 750 x 500 x 1200 (100L) for fuctional and complete operation as per the Drawing nr UB-GEH-M201.

Fire foam pipes, 50mm dia straight, (Type, nominal size, method of jointing, spacing and method of fixing supports, etc; as per the Drawings and Specification.

Fire main pipes, 50mm dia straight, (Type, nominal size, method of jointing, spacing and method of fixing supports, etc; as per the Drawings and Specification

Sprinkler head, 50mm dia straight. (Type, nominal size, method of jointing, spacing and method of fixing supports, etc; as per the Drawings and Specification

Page 1566: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 126,014.00

BF 126,014.00

22 00 00 - PLUMBING

22 05 23 General-Duty Valves for Plumbing Piping

1 Gate valve, 50mm diameter nr 1 68.00 68.00

22 13 16 Sanitary Waste and Vent Piping

2 m 6 17.00 102.00

22 40 00 Plumbing Fixtures

3 Floor Drain (FD) and trap 75mm nr 1 193.00 193.00

22 00 00 - PLUMBING

Additional Items

4

All Items hereunder to be described specified code of practice and regulations, kind quality, size method of fixing, finishes or surface treatments, etc; as per the Drawings nr UB-GEH-M201 and Specification.

Waste water pipes, 75 mm diameter, straight. (Type, nominal size, method of jointing, spacing and method of fixing supports, etc; as per the Drawings and Specification

All Items hereunder to be described with, kind quality, size nature of base method of fixing, etc; as per the Drawings nr UB-GEH-M201 and Specification.

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included.

Page 1567: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 126,377.00

BF 126,377.00

1 Exhaust Fan, 300 L/s. 0.3 KW. 220/1/60Hz wall mounted heavy duty nr 1 523.00 523.00

2 nr 1 2065.00 2,065.00

23 00 00 - Heating, Ventilating, and Air Conditioning (HVAC)

23 00 00 - HEATING, VENTILATING, AND AIR CONDITONING (HVAC)

All HVAC works shall be completed as per the Drawings and Specification.

All Items hereunder to be described with information such as appropriate to the procurement,capacity, design supply, execution, type, kind quality,size ,method of fixing, specified codes of practice,etc, as per the Drawings and Specification)

Supply and fix 200 mm dia muffler exhaust, fix to generator for complete and fuctional operation

Page 1568: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Additional Items

3

3.01 Generator Exhaust Louver nr 1 9704.00 9,704.00

3.02 Oil interceptor nr 1 3260.00 3,260.00

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included.

Page 1569: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 141,929.00

BF 141,929.00

26 00 00 - ELECTRICAL

26 05 26 Grounding and bonding for Electrical Systems

1 Grounding system Item 1 2535.00 2,535.00

26 41 13.13 Ligthning Protection for Buildings

2 Lightning system Item 1 0.00 0.00

26 24 16 Panel Boards

3 Fuel pump control panel (FPCP) nr 1 8981.00 8,981.00

4 Lightning and power panel (LPP-GR) nr 1 853.00 853.00

All works hereunder shall be completed as per the Drawings nr UB-GR-EL101-00, UB-GR-EL201-00 and Specification.

All Items hereunder to be described with information such as type, kind, number of cores, armoring and sheathing ,method of fixing,specified codes of practice ,etc, as per the Drawings and Specification)

All Items hereunder to be described with information such as type, kind, rated capacity, method of fixing, cores refrence to Specification, fuses, background,,specified codes of practice ,etc, as per the Drawings and Specification)

Page 1570: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 154,298.00

BF 154,298.00

ELECTRICAL (Cont'd)

26 27 26 Wiring Devices

Switches & Push Buttons

1 One way one gang switch 15A nr 1 10.00 10.00

2 One way two gang switch 15A nr 1 12.00 12.00

Power Outlets

3 Duplex receptable outlet, 230V, 20A normal power supply nr 4 19.00 76.00

4 Non-fusible disconnect switch, single pole, NEMA 4X nr 1 697.00 697.00

26 32 13 Engine Generators

All Items hereunder to be described with information such as appropriate to the procurement,capacity, design supply, execution, type, kind quality,size ,method of fixing, specified codes of practice,etc, as per the Drawings and Specification)

Page 1571: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

5 Item 1 181998.00 181,998.00

26 50 00 Lightning

6 nr 3 128.00 384.00

7 nr 4 128.00 512.00

8 nr 6 410.00 2,460.00

CF 340,447.00

BF 340,447.00

Supply, install, test and commissioning generator, for fuel tank generator room, 813KVA, 400V/231V. 60Hz (kind, size, fitting details, connections, power, head, accessories, cables, warranty) for operational and fuctional installation as per the Drawings and Specification.

All Items hereunder to be described with information such as appropriate to the procurement, type, kind quality,size ,method of fixing, specified codes of practice,etc, as per the Drawings and Specification)

Luminaire with open end wrap around diffuser, 2 no. of flourescent 36W/220V/60Hz lamps, electronic ballast & clear prismatic pattern (C2 type )

Surface mounted with a suspended rod luminaire, dust & water proof indoor industrial luminaire with moulded diffuser, double flourescent 36W/220V/60Hz lamps, electronic ballast & clear moulded polycarbonate diffuser of ip-65 (BH1- type )

Wall mounted bulkhead outdoor landscape clear wirh a 100W/220V/60Hz mercury vapour elliptical lamp, prismatic pattern mouleded polycarbonate diffuser of ip-65 (BH1- type )

Page 1572: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

ELECTRICAL (Cont'd )

26 00 00 - ELECTRICAL

Additional Items

1 The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included.

Page 1573: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 340,447.00

BF 340,447.00

27 00 00 COMMUNICATIONS

27 21 29 Data Communication switches and Hubs

27 21 29 Data Communication Wireless Access Points

1 Information outlet, flush type, 1 data, 1 telephone nr 1 48.00 48.00

2 Telephone outlet, wall mounted, flush type nr 1 34.00 34.00

3 Card reader, smart card nr 1 235.00 235.00

4 Electromagnetic door latch nr 1 383.00 383.00

5 Magnetic door contact switch nr 1 222.00 222.00

6 Request to exit button nr 1 309.00 309.00

7 IP fixed type CCTV, wal mounted outdoor camera (weather proof) nr 1 1520.00 1,520.00

27 15 00 Communications Horizontal Cabling

All Items hereunder to be described with information such as appropriate to the procurement, type, kind quality,size ,method of fixing, specified codes of practice,etc, as per the Drawings nr UB-GR-T201, 202 and Specification)

Page 1574: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

8 2 x CAT6A UTP cables m 15 12.00 180.00

9 24V loop cable, 2 x 25 mm² (fire resistant cable) m 21 11.00 231.00

27 00 00 Communications

Additional Items

10

ADDITIONAL

10.1 Control Panel for Access Control nr 1 1779.00 1,779.00

CF 345,388.00

BF 345,388.00

28 00 00 ELECTRONIC SAFETY AND SECURITY

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included.

Page 1575: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

28 31 00 Fire Detection and Alarm

1 Supply, install smoke detector nr 1 69.00 69.00

2 Supply, install heat detector nr 1 63.00 63.00

3 Multisensor detector nr 1 98.00 98.00

4 Manual pull station - 1.2 meters from FFL to the centre of the device. nr 1 69.00 69.00

5 nr 1 81.00 81.00

6 Fault isolator - ceiling mounted or as per site situation nr 1 77.00 77.00

7 nr 1 69.00 69.00

8 Fire alarm control panel nr 1 3077.00 3,077.00

28 00 00 ELECTRONIC SAFETY AND SECURITY

Additional Items

9

All Items hereunder to be described with information such as appropriate to the procurement ,type, kind quality, size method of fixing, specified codes of practice,etc, as per the Drawings and Specification)

Sounder/fire alarm bell/horn - 0.30 meters below from ceiling line to the centre of the device.

Control module - 0.20 meters below from ceiling line to the centre of the device

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included.

Page 1576: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 348,991.00

BF 348,991.00

31 00 00 EARTHWORK

31 10 00 Site Clearing

1 Site preparation, clearing site vegetation m² 63 2.00 126.00

31 23 16 Excavation

2 Excavation top soil for preservation, average depth 150mm m² 63 3.00 189.00

3 Excavating pits , depth excavation not exceeding 2 m m³ 65 8.00 520.00

31 23 16 Backfill

4 m³ 37 12.00 444.00

31 23 23.23 Compaction

5 m² 70 3.00 210.00

All works herein shall be completed in full compliance with the Drawings nr UB-GR-S101, UB-GR-S401.

Filling to excavation, average thickness > 0.25 m, arising from excavated materials, all fill shall be compacted to 75% relative density for cohesion-less soils as per ASTM D4254/ASTM D4293 or 95% maximum density as determined by ASTM D698 for cohesive materials

Surface treatment, compacting bottom of excavation, compaction to meet 85% of relative density for cohesion-less or 95% maximum density as determined by ASTM D1557 for cohesive materials per the Drawings and Specification).

Page 1577: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

31 31 16.26 Rock Removal

6 Disposal of excavated material, off site as stated in the Specification m³ 28 4.00 112.00

31 31 16 Termote Control

7 m² 65 1.00 65.00

8 m² 73 0.00 0.00

CF 350,657.00

BF 350,657.00

31 00 00 EARTHWORK

Additional Items

Termite control for the horizontal surface (method and type of treatment as per the Drawings and Specification)

Termite control for the vertical surface (method and type of treatment as per the Drawings and Specification)

Page 1578: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

1 The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included.

Page 1579: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 350,657.00

BF 350,657.00

33 00 00 UTILITIES

33 56 00 Fuel-Storage Tanks

As per Q&A no. 362 the word 'fiber glass' to be replaced by steel

1 Item 1 17278.00 17,278.00

2 Item 1 413.00 413.00

Additional Items

3

Supply and install buried steel fuel storage tank 1200, capacity including all accessories but not limited to piping works for fuctional and complete operation aas per the Drawings and Specification.

Supply, installing, testing, commissioning, adjusting, balancing, and guarantee including operation, maintenance, tools & spare parts, all Mechanical fittings including but not limited to piping works inside the pump station, valves tees, flanges, elbows, joints, air vent pipes, pressure gauges, pressure switches flow switches, balancing valves, flexible connectionsn rubber isolators, concrete bases, control panel, electrical connections, fittings, and all necessary to complete the works as per the drawings and specification and Engineer's instructions.

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included.

Page 1580: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CF 368,348.00

BF 368,348.00

41 00 00 Material Processing and Handling Equipment

41 22 00 Cranes and Hoist

1 nr 1 N/A

Additional Items

Supply and Install Electrical Overhead transfer Crane (single girder) as per the Drawings Number and Specification.

Page 1581: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2 The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included.

Page 1582: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for DOMESTIC AND FIRE WATER GENERATOR ROOM

CARRIED TO SUMMARY US Dollar 368,348.00

Page No

Domestic and Fire Water - Chlorination Building 27 336,558.00

Domestic and Fire Water - Water Tank 36 3,262,370.00

Domestic and Fire Water - Guard House 62 53,754.00

Domestic and Fire Water - Pump House and Annex 97 3,680,796.00

Domestic and Fire Water - Transformer Room 113 92,772.75

Domestic and Fire Water - Generator Room 135 368,348.00

Page 1583: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

US Dollar 7,794,598.75AMOUNT FOR SERVICES BUILDINGS FORWARD TO SUMMARY

Page 1584: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

INCLUDED IN MECHANICAL EQUIPMENT

Page 1585: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Item Nr. Description Unit Qty Rate Amount

BOUNDARY WALL

Wall 1 -With Retaining

03 00 00 - CONCRETE

03 11 13 Structural Cast-in Place Concrete Forming

1 m2 8020 27.00 216,540.00

03 31 00 Structural Concrete

2 m³ 2410 452.00 1,089,320.00

3 m³ 2750 685.00 1,883,750.00

03 41 00 - PRECAST CONCRETE

4 Wall panelling , size 5000mm x 3600mm. nr 549 3899.00 2,140,551.00

5 Barriers nr 925 339.00 313,575.00

32 31 36 SECURITY FENCES, GATES AND BARRIERS

Notwithstanding the Provisions of the Standard Method of Measurement of Building Works Seventh Edition, 1988 (SMM7) the following,concrete works are measured m³/m including. reinforcement bars and formworks. The Contractor is to include for cost of reinforcement and formwork with concrete works. . No additional charge or cost for reinforcement and formworks separately will be entertained due to lack or want of knowledge.

All concrete works herein shall be completed in full compliance with the Drawings and Specification.

Plain Concrete for blinding Beds 20 Mpa , Thickness ≤ 150mm, poured against the compacted soil, as stated in the Structural notes and Specification.

Reinforced concrete 35 Mpa, foundations ( footings): kind,quality, curing details etc. as stated in the Structural Notes and Specification.

Reinforced concrete 35 MPa, Walls , (kind, quality, curing details etc. as stated in the Structural notes and Specification).

Precast concrete panel wall including Column supports at 5000mm centres; precast concrete wall panels, stone effect both sides.

Precast concrete barriers; 3000 x 1000 x 1000, fair face all round; setting in position all as drawing and specification

High density high tensile mesh fence; including posts, end posts and strainer posts, excavation and concrete at 3380 centres; overall height 3000mm, in accordance with drawing and specification

Page 1586: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

6 Fencing m 2750 119.00 327,250.00

03 00 00 - CONCRETE

Additional Items

7 Item

Total for CONCRETE

CARRIED TO SUMMARY US Dollar 5,970,986.00

07 00 00 THERMAL AND MOISTURE PROTECTION

07 10 00 Damp proofing and Waterproofing

Substructure Waterproofing

1 m² 8020 2.00 16,040.00

2 m² 15270 5.00 76,350.00

3 Ditto - Horizontal surface. m² 5090 5.00 25,450.00

07 00 00 Thermal and Moisture Protection

Additional Items

4

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section, but not mentioned here. Any such items not listed below shall be deemed to be included

All metalworks herein shall be completed in full compliance with the Drawings and Specification.

Waterproofing works for substructure with vapour barrier 250 microns, horizontal surface, width > 300mm, as per the Drawings and Specification.

Waterproofing works for substructure with two layer of bitumen paint, vertical surface, width > 300mm as per the Drawings and Specification.

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section,but not mentioned here.Any such items not listed below shall be deemed to be included.

Page 1587: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for THERMAL AND MOISTURE PROTECTION

CARRIED TO SUMMARY US Dollar 117,840.00

31 00 00 EARTHWORK

31 10 00 Site Clearing

1 Site preparation, clearing site vegetation m² 8020 2.00 16,040.00

31 23 16 Excavation

2 Excavation top soil for preservation, average depth 150mm m² 8020 3.00 24,060.00

3 Excavating pits(16 nr), maximum depth ≤ 2.00m. m³ 26052 12.00 312,624.00

31 23 23.13 Backfill

4 m³ 20095 12.00 241,140.00

31 23 23.23 Compaction

5 m² 8020 3.00 24,060.00

31 23 16.26 Rock Removal

6 m² 5965 4.00 23,860.00

CF 641,784.00

BF 641,784.00

31 31 16 Termite Control

1 m² 8020 1.00 8,020.00

2 m² 4812 1.00 4,812.00

All works herein shall be completed in full compliance with the Drawings and Specification.

Filling to excavations, average thickness > 0.25 m, arising from excavated materials, all fill shall be compacted to 75% relative density for cohesion-less soils as per ASTM D4254/ASTM D4293 or 95% maximum density as determined by ASTM D698 for cohesive m

Surface treatments, compacting bottom of excavation, compaction to meet 85% of relative density for cohesion-less soils or 95% maximum density as determined by ASTM D1557 for cohesive materials per the Drawings and Specifications)

Disposal of excavated material, off site as stated in the Specification

Termite control for the horizontal surface (method and type of treatment as per the Drawings and Specifications)

Termite control for vertical surface (method and type of treatment as per the Drawings and Specifications)

Page 1588: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

31 00 00 EARTHWORK

Additional Items

3

Total for EARTHWORK

CARRIED TO SUMMARY US Dollar 654,616.00

03 00 00 Concrete 5,970,986.00

07 00 00 Thermal and Moisture Protection 117,840.00

31 00 00 Earthwork 654,616.00

AMOUNT FOR WALL 1 TO SUMMARY US Dollar 6,743,442.00

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section,but not mentioned here.Any such items not listed below shall be deemed to be included.

Page 1589: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

03 00 00 - CONCRETE

03 11 13 Structural Cast-in-Place Concrete Forming

1 m² 1245 27.00 33,615.00

03 31 00 Structural Concrete

2 m³ 1155 420.00 485,100.00

3 m³ 695 251.00 174,445.00

03 00 00 - Concrete

Additional Items

4

Wall 3 - Anti Blast (As per client answer for question No (321) Wall (2) replaced by Wall (3)

Notwithstanding the conditions in the Standard Method of Measurement of Building Works Seventh Edition, 1988 (SMM7) the following concrete works are measured m3/m2 including reinforcement bars and formworks. The Contractor is to include for costs of reinforcement and formwork with concrete works. . No additional charge or cost for reinforcement and formworks separately will be entertained due to lack or want of knowledge.

All concrete works herein shall be completed full incompliance with the Drawings and Specification.

Plain Concrete for blinding Beds 20 Mpa , Thickness ≤ 150mm, poured against the compacted soil, as stated in the Structural notes and Specification.

Reinforced concrete 35 MPa, foundations ( Strip Footing), (kind, quality, curing details etc. as stated in the Structural notes and Specification).

Reinforced concrete 35 MPa, foundations ( Neck), (kind, quality, curing details etc. as stated in the Structural notes and Specification).

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section,but not mentioned here.Any such items not listed below shall be deemed to be included.

Page 1590: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for CONCRETE

CARRIED TO SUMMARY US Dollar 693,160.00

04 00 00 - Masonry

04 22 00 - Concrete Unit Masonry

External walls

1 m² 1656 230.00 380,880.00

04 00 00 - Masonry

Additional Items

2

All Masonry works herein shall be completed full incompliance with the Drawings and Specification.

1500mm thick CMU wall, vertical, comprised with 500mm block work external side, 100mm sand filled cavity, 500mm block work internal side, (kind, quality and size of blocks, type of bond, mix of motar etc. to be included as per the details and Specification )

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section,but not mentioned here.Any such items not listed below shall be deemed to be included.

Page 1591: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

Total for Masonry

CARRIED TO SUMMARY US Dollar 380,880.00

07 00 00 THERMAL AND MOISTURE PROTECTION

07 10 00 Damp proofing and Waterproofing

Substructure Waterproofing

1 m2 1245 2.00 2,490.00

All metalworks herein shall be completed in full compliance with the Drawings and Specification.

Waterproofing works for substructure with vapour barrier 250 microns, horizontal surface, as per the Drawings and Specification.

Page 1592: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

2 m2 1840 5.00 9,200.00

3 Ditto - Horizontal surface. m2 460 5.00 2,300.00

07 00 00 Thermal and Moisture Protection

Additional Items

4 Item

Total for THERMAL AND MOISTURE PROTECTION

CARRIED TO SUMMARY US Dollar 13,990.00

09 00 00 - FINISHES

09 24 00 Cement Plastering

1 m² 3315 29.00 96,135.00

09 00 00 Finishes

Additional Items

2

Total for FINISHES

Waterproofing works for substructure with two layer of bitumen paint, vertical surface, as per the Drawings and Specification.

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section,but not mentioned here.Any such items not listed below shall be deemed to be included.

All metalworks herein shall be completed in full compliance with the Drawings and Specification.

Self coloured rendering (pre coloured mineral wall coating) for walls, External, width > 300mm, (thickness, kind, quality, composition, mix materials, nature of base, method of construction, layout and treatments, thermal insulation, moisture resistant treatment, method of jointing, etc. as per the Drawings nr A0-A933 and Specification).

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section,but not mentioned here.Any such items not listed below shall be deemed to be included.

Page 1593: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

CARRIED TO SUMMARY US Dollar 96,135.00

31 00 00 EARTHWORK

31 10 00 Site Clearing

1 Site preparation, clearing site vegetation m² 1245 2.00 2,490.00

31 23 16 Excavation

2 Excavation top soil for preservation, average depth 200mm m² 1245 3.00 3,735.00

3 Excavating pits(16 nr), maximum depth ≤ 2.00m. m³ 8950 12.00 107,400.00

31 23 23.13 Backfill

4 m³ 6980 12.00 83,760.00

31 23 23.23 Compaction

5 m² 1245 3.00 3,735.00

31 23 16.26 Rock Removal

6 m² 1970 4.00 7,880.00

31 31 16 Termite Control

7 m² 1245 1.00 1,245.00

8 m² 747 1.00 747.00

31 00 00 EARTHWORK

Additional Items

All works herein shall be completed in full compliance with the Drawings and Specification

Filling to excavations, average thickness > 0.25 m, arising from excavated materials, all fill shall be compacted to 75% relative density for cohesion-less soils as per ASTM D4254/ASTM D4293 or 95% maximum density as determined by ASTM D698 for cohesive material, as per the Drawings and Specifications

Surface treatments, compacting bottom of excavation (method of filling and compactions to be stated as per the Drawings and Specifications)

Disposal of excavated material, off site as stated in the Specification.

Termite control for the horizontal surface (method and type of treatment as per the Drawings and Specifications)

Termite control for vertical surface (method and type of treatment as per the Drawings and Specifications)

Page 1594: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

9

Total for EARTHWORK

CARRIED TO SUMMARY US Dollar 210,992.00

03 00 00 Concrete 693,160.00

04 00 00 Masonry 380,880.00

07 00 00 Thermal and Moisture Protection 13,990.00

09 00 00 Finishes 96,135.00

31 00 00 Earthwork 210,992.00

AMOUNT FOR WALL 3 TO SUMMARY US Dollar 1,395,157.00

03 41 00 - PRECAST CONCRETE

1 Precast Boundary Wall Panel m 202 940.00 189,880.00

03 41 00 - PRECAST CONCRETE

Additional Items

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section,but not mentioned here.Any such items not listed below shall be deemed to be included.

Wall 2 - without Retaining (As per client answer for question No (321) dated 23/10/2014 Wall (3) replaced by Wall (2)

All works herein shall be completed in full compliance with the Drawings and Specification.

Precast concrete panel wall including supports and foundation ; excavate pits for footing; Back filling and compaction ,precast footing; precast wall pedestal; precast boundary wall panel ; Isolation Joint , precast panel supports at 5000mm centres precast concrete wall panels, stone effect both sides, panel size 5000mm x 3600mm.

Page 1595: [XLS] · Web view36 164 5904 103 380 39140 4 656 2624 64 296 18944 1 538070 538070 1303 25 32575 363 17 6171 8 310 2480 940 17 15980 57 15 855 23 10 230 662973 662973 554 34 18836

AMOUNT FOR WALL 2 TO SUMMARY US Dollar 189,880.00

Wall Type 1 - With Retaining 6,743,442.00

Wall Type 3 - Antiblast 1,395,157.00

Wall Type 2 - With out Retaining 189,880.00

AMOUNT FOR Boundary Wall TO SUMMARY US Dollar 8,328,479.00

The Contractor is to list here and price any items shown on the Drawings, mentioned in the Specifications or required for the satisfactory completion of this section,but not mentioned here.Any such items not listed below shall be deemed to be included.