‘‘YGFC’ YGFC’ FAN COIL UNITSFAN COIL UNITS
NEW PRODUCTS - 2006NEW PRODUCTS - 2006
YGFC FAN COIL UNITYGFC FAN COIL UNIT• FACTORY LOCATED IN GUANGZHOU, CHINA
– CAPACITY = 300,000 UNITS/YEAR = 1,000 UNIT/DAY!
• CERTIFICATION– ISO 9001:2000, GB/T 19002:2000 CERTIFIED FACTORY
– GB/T 19232:2003 CERTIFIED TEST LAB (ONLY 2 IN CHINA)
FEATURESFEATURES
– CE (TUV) CERTIFIED
– CONFIGURATION: CONCEALED, CABINET, HORIZONTAL, VERTICAL
– COIL: 2 CHOICES, CONVENTIONAL OR DISTRICT COOLING
– 10 SIZES (70-600 L/S, 1-15KW COOLING)
– DRAIN PAN: DIE-FORMED, ANTI-RUST PAINTED, INSULATED
– MOTORS: DIRECT DRIVE, THERMAL PROTECTION, BALL BEARING• TESTING
– COIL PRESSURE TESTED AT 2400 KPA– MOTOR TESTED FOR EARTH LEAK AND CURRENT
YGFC FAN COIL UNITYGFC FAN COIL UNIT
YGFC FAN COIL UNITYGFC FAN COIL UNIT• SPECIFICATIONSPECIFICATION
– 3 OR 4 ROW COIL, WORKING PRESSURE 1600kPa
– FILTER: 6mm NYLON
– 1mm GALV.STEEL CASING FOR ADDED NOISE REDUCTION
– INSULATED PAINTED DRAIN PAN
– 10mm COATED FIBREGLASS INSULATED FAN DECK & COIL SECTION
YGFC FAN COIL UNITYGFC FAN COIL UNIT• OPTIONSOPTIONS
– CASING: FULLY POWDER COATED
– FILTER: 25 MM ALUMINUM
– FINS: HYDROPHILIC, EPOXY COAT, COPPER
– STAINLESS STEEL DRAIN PAN
– MOTORS: IP 23 AS STANDARD, 42 & 54 AS OPTION
– 6mm CLOSED CELL INSULATED RETURN PLENUM, ELECTRIC HEATER
YGFC FAN COIL UNITYGFC FAN COIL UNIT• ADVANTAGESADVANTAGES
– CHOOSE FROM 10 MODEL SIZES TO MATCH ROOM NEED
– LOW HEIGHT (250MM) SUITABLE FOR TOWER BLOCKS
– WHISPER-QUIET OPERATION
– RESISTANCE TO CORROSION
– ADAPTABILITY TO STANDARD OR DISTRICT COOLING APPLICATION
YGFC FAN COIL UNITYGFC FAN COIL UNIT
• ADVANTAGES
– EASE OF MAINTENANCE
– LOW RISK OF LEAKS FROM DRAIN PAN AND COIL CONNECTIONS
– LOW RISK OF BEARING WEAR
– LONGER MOTOR LIFE – LONGER UNIT LIFE!
– ECONOMICAL LIFE CYCLE
DISTRICT COOLINGDISTRICT COOLING• Definition
– Produce chilled water at a central plant
– Distribute to buildings for AC needs
– Charge subscribers based on actual usage
• Benefits– Diversity reduced capacity, reduced cost
– Large size $/Ton, 11kV, eff systems & eqpt, life
– Containment maintenance (AC vs WC), noise
– Cogeneration and use of waste energy
DISTRICT COOLINGDISTRICT COOLING• WHERE
– City Centers: large buildings & loads, premium space
– Airports: large buildings & loads, continuous operation
– Industrial Centers: many process loads, reliability
• DESIGN– Low flow (1.5 gpm/ton) high ΔT, small pipes & pumps
– Low supply chilled water temperature smaller AS
– Check for laminar flow in FCU poor cooling
– Reynolds number > 4000
– Ensure appropriate ΔT on airside of heat exchanger
YGFC FAN COIL UNITYGFC FAN COIL UNIT
• POINTS TO NOTE!
– THIS IS A ‘HIGH VOLUME’ PRODUCT - SIMPLE SPECIFICATION ALLOWS LOW COST & SPEEDS UP LEAD TIMES
– TARGET LOW END SPEC. PROJECTS, AND SALES TO DISTRIBUTORS AND END USERS
– LESS RANGE OF OPTIONS & SQ’S WHEN COMPARED TO ‘EUROPEAN’ FCU’S
– FCU CASING NOT THE MOST ATTRACTIVE!
– ARE YOU ABLE TO ORDER & HOLD STOCK UNITS??
YGFC FAN COIL UNITYGFC FAN COIL UNIT
• POINTS TO NOTE!
– THERMOSTATS & CONTROLS AVAILABLE FROM ASIA PACIFIC ARE NOT CE CERTIFIED
– VALVES ARE NOT FACTORY FITTED
– FILTER REMOVAL ON CEILING CONCEALED UNIT IS DIFFICULT AS IT REQUIRES SCREW REMOVAL
– EUROVENT CERTIFICATION WILL BE MADE LATE 2006
YGFC SOFTWAREYGFC SOFTWARE
YORK DESIGNED, INDEPENDENT OF YORKWORKS
YGFC SOFTWAREYGFC SOFTWARE
- GENERATES TECHNICAL SCHEDULES…
- GENERATES WORKS ORDER
YGFC SOFTWAREYGFC SOFTWARE
•ALSO GENERATES…ALSO GENERATES…
-OPTIMUM FCU CONTAINERISATION FOR SHIPPING
-CATALOGUE DATA SHEETS & TECHNICAL SPECIFICATIONS
-PRICE SUMMARY
WHO TO CONTACT….WHO TO CONTACT….TECHNICAL James Long ([email protected]),
DOCUMENTATION Alan Hinton ([email protected])
PRICING Alan Hinton ([email protected])
SQ’S & SQ PRICING
James Long ([email protected]), c.c. to Alan Hinton ([email protected])
ORDERS Jackey Que ([email protected]), c.c to James Long ([email protected])
SHIPPING Erica Wang ([email protected])
WARRANTY Ding yue ([email protected]), c.c to Kevin Lau ([email protected])
SOFTWARE Alan Hinton ([email protected])