14
5/07/2017 zencontrol wiring and installation 1

zencontrol wiring and installation 5/07/2017 · zencontrol wiring and installation 5/07/2017 8 1 x RC = 64 luminaires(ECG), 63 DALI devices(ECD) Up to 10 rooms per RC Simple setup

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: zencontrol wiring and installation 5/07/2017 · zencontrol wiring and installation 5/07/2017 8 1 x RC = 64 luminaires(ECG), 63 DALI devices(ECD) Up to 10 rooms per RC Simple setup

5/07/2017zencontrol wiring and installation 1

Page 2: zencontrol wiring and installation 5/07/2017 · zencontrol wiring and installation 5/07/2017 8 1 x RC = 64 luminaires(ECG), 63 DALI devices(ECD) Up to 10 rooms per RC Simple setup

5/07/2017 2zencontrol wiring and installation

ComparisonControl system models and applications

Page 3: zencontrol wiring and installation 5/07/2017 · zencontrol wiring and installation 5/07/2017 8 1 x RC = 64 luminaires(ECG), 63 DALI devices(ECD) Up to 10 rooms per RC Simple setup

Traditional LCM method

5/07/2017 3zencontrol wiring and installation

Page 4: zencontrol wiring and installation 5/07/2017 · zencontrol wiring and installation 5/07/2017 8 1 x RC = 64 luminaires(ECG), 63 DALI devices(ECD) Up to 10 rooms per RC Simple setup

▪ Highest overall cost using LCM method

▪ One channel for each luminaire (some allow a few luminaires per channel but with many limitations)

▪ Many installs have custom wiring / lead lengths making installation harder and maintenance more expensive

▪ Higher commissioning cost

5/07/2017zencontrol introduction 4

Traditional LCM method

Page 5: zencontrol wiring and installation 5/07/2017 · zencontrol wiring and installation 5/07/2017 8 1 x RC = 64 luminaires(ECG), 63 DALI devices(ECD) Up to 10 rooms per RC Simple setup

55/07/2017zencontrol wiring and installation

Typical LCM layout

Page 6: zencontrol wiring and installation 5/07/2017 · zencontrol wiring and installation 5/07/2017 8 1 x RC = 64 luminaires(ECG), 63 DALI devices(ECD) Up to 10 rooms per RC Simple setup

Hybrid solutionRoom control and marshalling box, LCM replacement

5/07/2017 6zencontrol wiring and installation

Page 7: zencontrol wiring and installation 5/07/2017 · zencontrol wiring and installation 5/07/2017 8 1 x RC = 64 luminaires(ECG), 63 DALI devices(ECD) Up to 10 rooms per RC Simple setup

▪ Wired in a similar method to traditional LCM layouts

▪ Replaces the LCM with one or more marshalling boxes

▪ Replaces the area controller with a Room controller

▪ Reduced overall cost compared to the LCM method

▪ Reduced commissioning

▪ More advanced features possible

5/07/2017zencontrol introduction 7

Hybrid solution

Page 8: zencontrol wiring and installation 5/07/2017 · zencontrol wiring and installation 5/07/2017 8 1 x RC = 64 luminaires(ECG), 63 DALI devices(ECD) Up to 10 rooms per RC Simple setup

85/07/2017zencontrol wiring and installation

1 x RC = 64 luminaires(ECG), 63 DALI devices(ECD)

▪ Up to 10 rooms per RC

▪ Simple setup of controls across rooms and corridors

▪ Automatic setup of luminaires and controls connected to each output

▪ Cost savings, an inexpensive MB can replace a full featured controller per room

Typical LCM layout with Marshalling boxes

Page 9: zencontrol wiring and installation 5/07/2017 · zencontrol wiring and installation 5/07/2017 8 1 x RC = 64 luminaires(ECG), 63 DALI devices(ECD) Up to 10 rooms per RC Simple setup

Room controlfor simpler wiring and commissioning

5/07/2017 9zencontrol wiring and installation

Page 10: zencontrol wiring and installation 5/07/2017 · zencontrol wiring and installation 5/07/2017 8 1 x RC = 64 luminaires(ECG), 63 DALI devices(ECD) Up to 10 rooms per RC Simple setup

▪ Easiest commissioning

▪ Wire rooms together using soft wiring (normally standard cable lengths + t-pieces)

▪ One room controller can support 64 luminaires (ECG) and 63 DALI control devices (ECD)

▪ Less fit-off points

▪ Easier to expand

▪ Works out the box / with automatic commissioning of standard features

▪ Most features supported with room control

▪ Fastest to setup, operate and maintain

5/07/2017zencontrol introduction 10

Room control

Page 11: zencontrol wiring and installation 5/07/2017 · zencontrol wiring and installation 5/07/2017 8 1 x RC = 64 luminaires(ECG), 63 DALI devices(ECD) Up to 10 rooms per RC Simple setup

115/07/2017zencontrol wiring and installation

1 x RC + T - pieces = 64 luminaires(ECG), 63 DALI devices(ECD)

▪ Flexible installation

▪ Lowest overall cost

▪ Lowest commissioning time and maximum features

▪ T-piece / soft wiring removes the need for marshalling boxes

▪ Allocation of 64 devices can be split up in any combination with automatic setup of 10 rooms

Typical Room control layout

Page 12: zencontrol wiring and installation 5/07/2017 · zencontrol wiring and installation 5/07/2017 8 1 x RC = 64 luminaires(ECG), 63 DALI devices(ECD) Up to 10 rooms per RC Simple setup

Application controller

5/07/2017 12zencontrol wiring and installation

Page 13: zencontrol wiring and installation 5/07/2017 · zencontrol wiring and installation 5/07/2017 8 1 x RC = 64 luminaires(ECG), 63 DALI devices(ECD) Up to 10 rooms per RC Simple setup

▪ Fast

▪ Best used with stairwells / lobbies / carparks

▪ Suits exposed ceilings

▪ Supports 64 luminaires (ECG) and 63 DALI control devices (ECD)

▪ Manual commissioning of groups / rooms

▪ Auto replacement features found on Room control are not available on Application controllers

5/07/2017zencontrol introduction 13

Application controller

Page 14: zencontrol wiring and installation 5/07/2017 · zencontrol wiring and installation 5/07/2017 8 1 x RC = 64 luminaires(ECG), 63 DALI devices(ECD) Up to 10 rooms per RC Simple setup

145/07/2017zencontrol wiring and installation

Typical Application controller layout