Transcript
Page 1: 13010-02-104 C [Proposed First]€¦ · Wall Type 4 (W4) 158mm internal metal stud partition (to underside of roof soffit) Spec Ref: 25-15-25/135 NOTE: All metal stud partitions to

D102

D10

8D

101

D10

3D

104

D10

5

D10

6

D107

ATC - Office OCF01

StorageF04

StairwellF02

ATC - OrderlyF03

Classroom (ACF)F05

Classroom (shared)F06

Classroom (ATC)F07

Radio RoomF08

CorridorF09

W103W102

W101

W10

8

W107 W106

W10

5W

104

02 02

03 03

04 04

05 05

01 01

B

B

C

C

D

D

E

E

A

A

A:A108

B:B108

8600

mm

130m

m

130mm

130m

m13

0mm

130m

m

100mm

C:C109

D:D109

roof

pitc

h 25

deg

rees

roof

pitc

h 25

deg

rees

RWP

RWP

250m

m25

0mm

130m

m

5322mm

E:E110

RWP

RWP

RWP

01106

South Elevation

107

Eas

t Ele

vatio

n

02

North Elevation

01107

106

Wes

t Ele

vatio

n

02

540m

m15

00m

m45

60m

m14

0mm

140mm 864mm 625mm 490mm 2250mm 1360mm 140mm

140m

m15

00m

m14

0mm

861m

m15

00m

m

140mm

140m

m

140mm510mm1500mm2210mm140mm 2260mm 1500mm

140m

m14

0mm

140mm 1890mm 1500mm

1695mm

2679

mm

42mm

2682

mm

832m

m14

93m

m

750mm

3361

mm

2432mm

LIFT

1446

mm

130m

m

1493

mm

1500mm

6600

mm

1100

mm

4221

mm

4100

mm

5720mm 5280mm 4220mm 4100mm

140m

m

140m

m54

0mm

Clear

1615mm

Void

W1

W4

W3

Date: Scale:

Drawn by: Checked by:

Drawing title:

Client:

Project:

Notes:

ChkdByDateRev Notes

Proposed FirstFloor Layout

Reserve Forces &Cadets Association

Joint Cadet CentreTottenham

File Ref: (internal use only)

Drawing no: Rev:

13010-02-104 C

Do not scale dimensions from this drawing.Dimensions marked with an asterisk thus * are open sitedimensions to be confirmed on site.All given dimensions are to be checked on site when setting out and any discrepancy reported immediately.

03.02.14 1:50@A1

sa spc

c01

A 14/3/14 Design development sa spc

General updates to layout and lift specification

B 27/3/14 sa spc

Updates for tenderC 10/6/14 spc gdw

KEY:

Proposed First Floor Layout1:50@A11

Line to indicates external face of external wall below

NOTE:Drawings to be read in conjuntion with BPR specification 13010-02-sch03

NOTE:All setting out taken from gridline to:- Centreline of concrete infill to external walls.- Face of blockwork for internal partitions.

NOTE:For door and ironmongery schedule refer to BPR document 13010-02-sch06

13010-02 Hazard NotesPlease be aware of the following Hazards have been identifed in relation to the works shown on this drawing

ID Hazard Action1 Works at Height Principle Contractor to

ensure appropriate barriers, guarding are in place and minimise heavy lifting where possible. PC to provide method statement accordingly.

2 Access to roof Provide safe access to roof. Ensure appropriate barriers, guardings are in place to work safely. Principle contractor to provide method statement accordingly

3 Roof finish vunerable to damage during works

Protect roof finish at all times

Wall Type 1A (W1A)280mm ICF external wall construction with brick slips.Spec Ref: 25-15-35/140

20-00-75/185Pitched roof structure

Blue dashed line indicates structural gridlines

Wall Type 4 (W4)158mm internal metal stud partition (to underside of roof soffit)Spec Ref: 25-15-25/135

NOTE:All metal stud partitions to first floor are W4 type.

Rainwater pipeSpec Ref: 50-10-00/110

Indicates proposed location of steel beams. Refer to SE drawings and specification for details

Wall Type 3 (W3)106mm internal metal stud partitionSpec Ref: 25-15-25/135

NOTE:For full scope of internal finishes refer to BPR document 13010-02-sch07

Dashed line to indicate proposed location of steel supporting structure. Refer to SE drawings for details

Recommended