GE Power SystemsGenerator
Reformatted, February 1999 with2500INSPMG
Permission of Electric Machinery
These instructions do not purport to cover all details or variations in equipment nor to provide for every possiblecontingency to be met in connection with installation, operation or maintenance. Should further information be desired orshould particular problems arise which are not covered sufficiently for the purchasers purposes the matter should bereferred to the GE Company.
Electric MachineryPMG Instruction Manual
2500INSPMG Electric Machinery
2
I. CONSTRUCTION
The PMG stator has a single phase winding in a laminated core. The rotor contains 12 strong permanent mag-nets. The PMG is coated with a fungus and moisture resistant varnish. The PMG is bolted to the end of themain generator shaft, outboard of the diode wheel and exciter.
With reasonable care the PMG will give years of trouble-free service. It is not adversely affected by a deadshort at its terminals for a short time. Prolonged overloads or short circuits can damage the windings.
CAUTION
Do not apply ac or dc voltage to the winding of the PMG that will cause currentto flow through the winding.
II. DESCRIPTION OF OPERATION
The brushless excitation system with a PMG is an independent, reliable device for providing dc excitationcurrent to the main generator. Rotation of the permanent magnet furnishes ac power which is rectified andcontrolled by the voltage regulator for excitation of the exciter field. Alternating current is produced by theexciter and rectified by the diode assembly. The output of the diode assembly is fed directly to the main gener-ator field.
The PMG is self-ventilated by the inherent fan action of the diode wheel. Air is drawn in through the exciterassembly and passes over the PMG.
III. INITIAL INSPECTION AND STORAGE
If not mounted on the main generator, the PMG parts are shipped in a foam sealed container. Desiccant isincluded and unpainted surfaces are rust protected. This provides adequate protection for indoor storage of3 to 6 months. Inspect for shipping damage.
The PMG motor is a strong magnet. It should be covered to keep it from picking up iron filings. Large ironmasses should not touch the rotor as this could demagnetize the rotor.
Rotor Stator
Electric Machinery 2500INSPMG
3
IV. ASSEMBLY
Follow the instructions and drawings supplied with the exciter.
The PMG stator weight is 32 pounds. The rotor weight is 31 pounds.
After mounting the PMG stator and rotor, measure the PMG air gap (0.0880.083 inches) at 4 positions 90apart. Center the PMG rotor so that the air gaps are whin 5% of the average. Tighten the mounting bolts.
Check to make sure that all bolts are torqued as required. Bend all lockplates and install lock wires to securethe critical bolts.
V. PERIODIC MAINTENANCE
The PMG should be cleaned with the same regularity and tin the same manner as the main generator. All leadwires should be in good condition and tightly fastened. The corrosion resistant coating should not be dam-aged. Any connections removed and replaced should be sprayed with a good quality, air drying insulatingvarnish.
WARNING
Adequate cleaning requires solvent use. Provide adequate ventilation andavoid contact with skin. Use extreme caution with petroleum solvents, astheir fumes are highly flammable.
For best results, apply solvents under pressure using an aspirator or similar device with a clean, dry com-pressed air supply. Less efficient, but acceptable means of applying solvent include self-contained (garden-type) sprayers, vacuum cleaner with spray attachment, portable sprayers and so forth.
Initial cleaning should be done with a slow drying solvent having good oil and dirt cutting properties. Thisshould wash out most of the dirt, oil and soot. Use Stoddard solvent, mineral spirits or alcohol. This shouldbe followed by a quick drying solvent, such as Freon-TF, which finish-cleans and leaves the wheel dry.
VI. INSULATION RESISTANCE
The PMG stator insulation resistance should be over 50 Megohms when tested with a 1,500 volt megger.
A low megger reading can be caused by dirt, moisture, or insulation damage (usually at some terminal).Cleaning and drying is recommended.
VII. LOSS OF EXCITATION
If the PMG is suspected, disconnect the PMG from the regulator and check for winding continuity. The nor-mal resistance of the PMG is 0.1 ohm. If the unit is running the open circuit voltage should be 100 to 150volts ac.
If the problem still cannot be corrected, then thoroughly examine the main generator and control circuitry.At this time contact the nearest Service Office for assistance.
Reference:Electric MachineryPMG Instruction Manual 9/81
General Electric CompanyOne River Road, Schenectady, NY 12345518 385 2211 TX: 145354
GE Power Systems
HomeGE Power.comMain Table Of ContentsTab 1. IntroductionLM6000-Title PageLM6000-Table of ContentsLM6000-Front Matter
Tab 2. LM6000 System PackagesTab 2.01 GTG Gas Turbine Generator PackageLM6000_SP-D-GTGLM6000_SP-M-GTGLM6000_SP-O-GTG
Tab 2.02 GTE Gas Turbine EngineLM6000_SP-D-GTELM6000_SP-M-GTELM6000_SP-O-GTE
Tab 2.03 HVE Generator and High Voltage Electrical SystemsLM6000_SP-D-HVELM6000_SP-M-HVELM6000_SP-O-HVE
Tab 2.04 TLS Turbine Lube Oil SystemLM6000_SP-D-TLSLM6000_SP-M-TLSLM6000_SP-O-TLS
Tab 2.05 GLS Generator Lube Oil SystemLM6000_SP-D-GLS-60LM6000_SP-M-GLSLM6000_SP-O-GLS
Tab 2.06 HSS Hydraulic Start SystemLM6000_SP-D-HSSLM6000_SP-M-HSSLM6000_SP-O-HSS
Tab 2.07 FS Fuel SystemTab Gas Turbine DescriptionLM6000_SP-D-G-FS
Tab Gas Turbine Maintenence DescriptionLM6000_SP-M-G-FS
Tab Gas Turbine Operational InformationLM6000_SP-O-G-FS
Tab 2.08 WIS Water Injection SystemLM6000_SP-D-WISLM6000_SP-M-WISLM6000_SP-O-WIS
Tab 2.09 WWS Water Wash SystemLM6000_SP-D-WWSLM6000_SP-M-WWSLM6000_SP-O-WWS
Tab 2.10 CDP Purge SystemSection Not Applicable to this Project
Tab 2.11 VCA Ventilation and Combustion Air SystemLM6000_SP-D-VCALM6000_SP-M-VCALM6000_SP-O-VCA
Tab 2.12 SS Sprint SystemLM6000_SP-D-SSLM6000_SP-M-SSLM6000_SP-0-SS
Tab 2.13 FDS Fire and Gas Detection SystemLM6000_SP-D-FDSLM6000_SP-M-FDSLM6000_SP-O-FDS
Tab 2.14 TAS Turbine Auxiliary SystemLM6000_SP-TAS
Tab 2.15 AI Anti-IcingLM6000_SP-AI
Tab 2.16 CS Control SystemLM6000_SP-D-CSLM6000_SP-M-CSLM6000_SP-O-CS
Tab 2.17 LVS Low Voltage AC and DC SystemsLM6000_SP-D-LVSLM6000_SP-M-LVSLM6000_SP-O-LVS
Tab 3. LM6000 Specifications, Maintenance, and Technical ProceduresTab 3.01 Gas Turbine Generator PackageHS_TP5128HS_TP7100HS_TP7101HS_TP7102HS_TP7103HS_TP7104HS_TP7105HS_TP7106HS_TP7107HS_TP7108HS_TP7109HS_TP7110HS_TP7112HS_TP7113HS_TP7114
Tab 3.02 Gas Turbine EngineHS_TP7200
Tab 3.03 Generator and High Voltage Electrical SystemsHS_TP7300HS_TP7302
Tab 3.04 Turbine Lube Oil SystemHS_TP5803HS_TP5804HS_TP7701HS_TP7709
Tab 3.05 Generator Lube Oil SystemHS_TP7702HS_TP7703HS_TP7704HS_TP7705HS_TP7707HS_TP7708HS_TPXXXX
Tab 3.06 Hydraulic Start SystemHS_TP6002HS_TP7800
Tab 3.07 Fuel SystemsHS_TP5604HS_TP5609HS_TP7503
Tab 3.08 Water Injection SystemHS_TP5703HS_TP5704HS_TP5702
Tab 3.09 Water Wash SystemHS_TP6403HS_TP6404HS_TP7900HS_TP7901HS_TP7902
Tab 3.10 CDP Purge SystemSection Not Applicable to this Project
Tab 3.11 Ventilation and Combustion Air SystemsHS_TP7400
Tab 3.12 Sprint SystemHS_TP-SS
Tab 3.13 Fire and Gas Protection SystemHS_TP7600
Tab 3.14 Turbine Auxiliary SystemHS_TP-TAS
Tab 3.15 Anti-IcingHS_TP-AI
Tab 3.16 Control SystemHS_TP6501HS_TP8001HS_TP8002HS_TP8004HS_TP8005
Tab 3.17 Low Voltage AC and DC SystemsHS_TP6601HS_TP6602HS_TP6603HS_TP6604HS_TP6605
Tab 4. DrawingsTab 4.01 GA or Foundation674204674218674284674201674200674209674290674224
Tab 4.02 Flow and Instrument Diagram674254674260674248674232674268674270674244674239674269674262674272674051
Tab 4.03 One-Line or Plan and Elevation674031674018674022674023674014674032
Tab 4.04 Interconnect Diagrams674009674006674007
Tab 4.05 Schematics674035674048674049674041674047674044674934674931674037674930674932
Tab 4.06 Wiring Diagrams674084674077674088674057674058674091
Tab 4.07 Worksheets674965674962674794674145674964674292674293674147674148674143674146
Tab 4.08 Lifting and Shipping674225674226
Tab 4.09 Symbols and Misc674005674231674013
Tab 5. Vendor DocumentationTab Air Technologieshs_780-1812
Tab Allen Bradleyhs_abr30-5mmpbhs_abrbull800ehs_bulletin800h-800t
Tab Amot Controls Corporationhs_ac936A971modelb
Tab API Heat Transferapi-schmidt_brettenhs_bascowhitlock
Tab Ashcrofths_1112sdsnubberhs_250-1997-bhs_achgaugetemphs_1279hs_model1377hs_achbullentindu-1hs_1377_iomhs_drawingngp70hs_250-1068e_bimetalhs_aspuldam1106hs_ach1279-1379hs_bulletinoh-1
Tab Atkomatichs_ak15830serieshs_15000serieshs_32800serieshs_15800specshs_15800manualhs_31800serieshs_ak30800serieshs_akc30000series
Tab AWV Inc.hs_drawing31577hs_drawing31578hs_drawing24471hs_awv43528hs_drawing24473hs_drawing24475
Tab Barton Instrument Systemhs_tmssec03
Tab Beckwith Electric Co. Inchs_be3425ib
Tab Bently NevadaAC-DC Power Supplies Operation and Maintenance Manual (3500 Monitor Manuals)128158-01129766-01129767-01129768-01129770-01129771-01129772-01129773-01129774-01129777-01130432-01134542-01134938-01134939-01135545-01136973-01137412-01138629-01141706-01142836-01143488-01143489-01143490-01146282-01146479-01148636-01161580-01162291-01163860-01
Tab Brennan Industries Inchs_biseries64
Tab Bruninghs_thseries
Tab Brushhs_hb959200900ghs_hb959200900f
Tab CCI Thermal - Caloritechhs_datasheetsiomhs_xbhs_cci509124
Tab Check Allhs_checkallcat-03
Tab Chromaloxhs_chxpf490b-cehs_pd408-13hs_pd408-16hs_pd448hs_chxarmto3hs_chxpd419-9hs_b-107_tmo3_mo
Tab Dollinger Corporationhs_dolae-229hs_ae-229
Tab Donaldsonhs_hmk04-24p165354hs_f112074hs_hmk05-25hs_f112075
Tab Durabla Fluid Technology, Inc.hs_dftdr_cataloginletvalvehs_durablafluidglchs_inlinecheckvalveshs_dft_imm
Tab Dwyer Instruments, Inc.hs_2000_caths_e-571950g_iom
Tab Eaton - Tedecohs_tdc3e8501-10hs_tdc3e8501hs_tdcmf9639lkpss
Tab Edward Vogt Valve Companyhs_seriess74
Tab Emerson - Danielhs_dnlcat1200
Tab Emerson - Fisher Controlshs_efc67c5469hs_efcbull71195hs_fcdesignez5118hs_dwgaj3324hs_form1570hs_form1292hs_form5050hs_form1151
Tab Emerson - Rosemounths_rosemount3051hs_00809-0100-4001hs_drawing00078-0240hs_rm3051shs_ero813-100-2654
Tab Ernsths_e54524
Tab Falk Couplinghs_458-830hs_458-110
Tab Flow Technologyhs_tm-86675hs_fchft01
Tab Fluid Comphs_doc06en003246
Tab GE EnergyGENERATOR (336-670, -673, -674, -677)I. GENERALGEK 95149GEK 95153
II. OPERATIONA. ProtectionGEI 85803GEK 75512
B. GeneralGEK 46135GEK 95161A
C. MonitoringGEK 95168
III. MAINTENANCEA. GeneralGEI 58519GEI 85802GEK 103566GEK 103672GEK 103731GEK 46117GEK 95156GEK 95157
B. RotorGEK 103667
C. StatorGEK 7613
D. BearingsGEK 95124GEK 95150
IV. DRAWINGSA. Drawings194D8464118E4329114E3607585A1353361B9400111E5593111E5593114E3601363A1756
B. Excitation2100-INS-324A2500-INS-4022500-INS-PMG
LM6000 INLET AIR FILTER HOUSEhs_geaep_af-iomDrawingshs_geaep_af-dwghs_geaep_571204hs_geaep_969200hs_geaep_571225hs_geaep_969225hs_geaep_571226hs_geaep_969226hs_geaep_571239hs_geaep_969239
Vendor Documentationhs_geaep_af-manhs_geaep_tp01hs_dnstgS409hs_geaep_tp02hs_dragonvalves1.3hs_geaep_tp03dwyer1950_1950g_caths_geaep_tp04hs_im018r04hs_geaep_tp05hs_ssvim02000hs_geaep_tp06hs_ssv7-1997hs_geaep_tp07hs_muntershs_geaep_tp08hs_rcm7000-8000hs_geaep_tp09hs_ero71-400hs_geaep_tp10hs_ero71-5081hs_geaep_tp11hs_ero813-100-4001hs_geaep_tp12hs_series78hs_geaep_tp13hs_vicstyle75-77
Tab GE Packaged Power L.P.hs_dwg289174hs_drawing289188deh40472hs_drawing287705gei100600hs_geh-6721hs_gemotor5kehs_gesgfk-1055ahs_gesgfk-0448ehs_geh4961
Tab GHX Incorporatedhs_ghxhos-Fit-cat
Tab Goulds Pumps, Inc.hs_rssvhs_ssvhs_ssvseries
Tab Gulton Stathamhs_pa3000
Tab Hansen Technologieshs_hansenstseries
Tab Hartzell Fan Inc.hs_hlla-156dr1hs_drawinghdd-20085-1hs_man-iom
Tab Hayden Industrial Productshs_drawing019802hs_iommanualhayden
Tab Hilliardhs_hilfs15b150p-001hs_hilfs20b150p-002hs_hiliom01
Tab Hoke, Int.hs_hok79002-06
Tab Hydraquip Corporationhs_ipv-dbv-10hs_hydpllg05ths_rcn2026
Tab ITT - Neo-Dynhs_nd162phs_nd132phs_nd100t-chs_nd180phs_nd132t-chs_nd100phs_catalog37-nhs_suppinstructions
Tab Kencohs_99m50-99m75
Tab Kepner Products Companyhs_kep-o-sealhs_kp1912f18hs_kp5900
Tab KF Industrieshs_kffiom3-00iomhs_db-15b
Tab Kitz Corporationhs_k-150uoamhs_catalogsteel
Tab Linc Manufacturinghs_lnc800-455-linc
Tab Lovejoy, Inc. / Magnaloyhs_techdatacat
Tab Magnaloyhs_ap9911
Tab Marathonhs_sb300hs_sb181_iom
Tab Marshall J. Brownhs_mjb1220
Tab Marvel Engineering Companyhs_nols-101
Tab Master Lockhs_msl7000-0031
Tab Meriamhs_mrm951-2
Tab Mincohs_s19350pdhs_rtd-2
Tab Mueller Steam Specialityhs_c18-c19_761-762-764-sshs_185-186-sshs_c30-c31_861-862-sshs_mllgencaths_mueller303ht
Tab Opw Engineered Systemshs_opw2726hs_sightflow
Tab Orange Researchhs_gn128-1201hs_series1502-1505
Tab Pall Industrialhs_8640serieshs_pll9850hs_0937servicehs_aab24424d2y1ahs_acpadb24424y1hs_pihcsi-864
Tab Protecto Sealhs_psldrw6672hs_plsimi6670hs_v670_v6670hs_pls860series
Tab Rexnord -Thomas Couplinghs_tcflexdisc
Tab Roto Jet Pumphs_jetroiii3x2hs_jetiom12-02hs_jetrjos1hs_rj-iom12-02
Tab Sauer Danfosshs_bln09949hs_bln09947hs_bln10029hs_blnycseries
Tab Sun Hydraulicshs_rpec-qbn
Tab TCF Aerovenths_d-29597-00hs_r-25766-00hs_c-29592-00hs_d-31014-00hs_im1005-00hs_im1656-97hs_im1601-00hs_tfces-191hs_avbu476hs_tfcbulletin456hs_avbu466
Tab Thermal & Mechanical Equip.hs_tme1572-06-048-000hs_tme198029
Tab Tuthill Corporationhs_tut22-1
Tab Tyco - Anderson, Greenwoodhs_05-9040-087hs_form05-9040-071hs_datasheetd-series
Tab Vaw Systemshs_ss6625d2hs_vws61002
Tab Velanhs_vel-te-2001
Tab Voithhs_g818ehs_dbv-1092hs_inst_ope_comm
Tab Watts Regulatorhs_isb6000hs_is-c7350-1hs_iom-15002500hs_iom-18002800hs_wwtballvalves
Tab Weed Instrumenths_0015-001-0001hs_305rtd
Tab Wilson Fire EquipmentO&M MANUAL: FIRE & GAS PROTECTION SYSTEM LM6000hs_wfelm6000_sheeths_wfelm6000_faultshs_wfelm66creqxls
Sec.01 General Overviewhs_wfelm6000_over
Sec.02 Allestec Fire Panelhs_alle800systembhs_alle800-1537hs_alle800systemf
Sec.03 Gas Detectorshs_det958382hs_det95-8472hs_wfe90-1151hs_wfeeq3700dciohs_wfe90-1118hs_wfe95-8533hs_det901138hs_wfeq900hs_wfe95-8526hs_wfe95-8440-01hs_wfe90-1041-03hs_wfeeq2200dcuhs_wfe95-8521hs_fwl27100
Sec.04 Flame Detectorshs_wfe95-8554
Sec.05 Thermal Detectorshs_wfe6ds116hs_wfe6dsus24
Sec.06 C02 Equipmenths_kiddehs_wfep-4574-g
Sec.07 Manual Pull Stationshs_wfemvc-0095hs_wfem-27hs_wfej-11hs_wfem-29hs_mdcbgpb
Sec.08 Strobeshs_mdcxb11hs_wfe6ds096
Sec.09 Hornshs_mdcdb3hs_wfe6ds094
Sec.10 Misc Equipmenths_wfegua-guf-eahfhs_abt1718503hs_wfeabt-0708464hs_abtzaghs_wfe05-0003hs_wfe60947-3hs_wfea200866hs_cmpt3cds-pbhs_wfeil60077hs_wferfoup1p8hs_wferfoup5p12hs_ftkmpt100mpt98hs_ftkim-mpt100hs_wfehw151hs_wfe33jhs_wfep105075hs_wfep105076hs_wfefs8499hs_wfe6ps-108hs_wfersserieshs_wfequartzhs_wfets32ha_wfeiso12cylhs_wfemfld14hs_wferack14hs_wfemfld2-12hs_wfewfco2ps-a39khs_wferm100lbhs_wfewilson05
Tab Woodward Governor Co.hs_woo40156hs_woo03209hs_woo85586v1ghs_woo85586v2ghs_woo03213hs_woo03253hs_woo26229hs_woo40154hs_woo40185hs_woo40181
Tab Yokogawa Industrial Automationhs_1c21d1-01e-ycahs_yf100im1f2b401yia
Tab Zokhs_imwashlm6000
On-line HelpSearch HelpNavigate HelpZoom Help