UPS
MaintenancesUPS
650VA - 260kVA
Batteries 12V
7.2AH - 260AH
UPS Rental
1kVA -300kVA UPS
Repair
An introduction of our company -Monster UPS, who we are & what we do for you.
2
COMPANY DETAILS
MONSTER UPS ENTERPRISECo Reg No: JM0797063-HGST Reg No: 000451112960Co Reg Address: 25.03A, Level 25,
Johor Bahru City Square Office Tower106-108, Jalan Wong Ah Fook80000 Johor Bahru,MalaysiaTel: 07-208 7447Fax: 07-208 7401
DIRECTORMr.Loke Yew SengExperiences in UPS and Battery Industry for over 10 years Contact: 016-3856 [email protected]
KEY PERSONNEL
Malaysia -Co. Reg. JM0797063-HMONSTER UPS ENTERPRISE 25.03A, Level 25,JB City Square Office Tower106-108, Jalan Wong Ah Fook80000 Johor Bahru, Malaysia
Singapore -Co. Reg. 2017020477EMONSTER UPS PTE LTD10 Anson Road #10-11, International Plaza 079903 Singapore
Mickey LokeContact: 016-3856 [email protected]
3
FFEATURES :
● Absorbent Glass Mat (AGM) technology for
efficient gas recombination of up to 99%
and freedom from electrolyte maintenance.
● Robust plate for extended life span.
● Can be used in any orientation and none
Spillable.
● Designed Life 10 years @ 25°C
● Not restricted for air transport
Complies with IATA/ICAO requirement
● APPLICATION STANDARD
● UL- recognized component
● ISO 9001 -2000 / KS A9001-2001
ISO 14001-2004 / KS A14001-2004
VVT 12 - 100 - Specifications
Headquarters : 84-11, Namdaemunno 5-ga, Jung-gu , Seoul . 100-753 C.P.O Box 2810 Seoul . South Korea.
Valve Regulated Battery Designed for Uninterruptable Power Supply (UPS) , Communication Emergency Lighting , Security System , Standby Power and Other General Purpose.
VT12V - 100 VALVE REGULATED LEAD ACID BATTERY FOR STANDBY POWER APPLICATIONS 12V 100AH @ 10HR RATE
AApprox WWeight VVoltage Per Unit EElectrolyte IInternal Resistance MMax Disc. Amp
30.2 kg 12.85 AGM Starved 3.5 m Ohms 750 Amps (5 sec)
Deep Cycle AGM Range VRLA
UPS BRAND WE CARRY
BATTERY BRAND WE CARRY
VRLA BATTERY12V 4.5AH to 260AH
NICAD BATTERY12V 4.5AH to 260AH
DEEP CYCLE BATTERY12V 4.5AH to 260AH
UPS / Instrumentation ControlTelecommunication / PA / PABX SystemEmergency Lighting / SolarFire Alarm / IntercomEngine Starting / Signaling (Railway)Switch Tripping And ClosingPortable Power Packs
SINGAPOREFIDA INTERNATIONAL (S) PTE LTDBlock 16 Kallang Place#06-02, Singapore 339156Tel: (65) 6357 0668
MALAYSIAFIDA SYSTEMS (M) SDN BHDTel: (60) 3 8024 9151
INDONESIAPROLiNK INDONESIATel: (62) 21 3483 1777
Technical Support Hotline:Singapore (65) 6357 0666Malaysia (60) 3 8023 9151Indonesia (62) 21 3482 1717
Operating HoursMonday - Friday: 9.00am - 6.00pm
CATALOGUE
UNINTERRUPTIBLEPOWER SUPPLY (UPS)
Protecting Your Data
Your Inspirations. Our Innovations.
High End UPS Brand: APC, VERTIV (Liebert Emerson), REILLO, MGE, MERLIN GERIN
Affordable UPS Brand: PROLiNK, INVT
Battery Brand: MSB, ALCAD, POWERBATT, DEAWOO, RITTAR, LEOCH, YUASA etc
Server andNetwork Power SolutionsSmart-UPS®
Performance power protectionfor servers and networks
120V/208V
BasicProtection
99.999%Availability
GXT4™
700VA - 3kVA
Fully Digital Dual DSP Controlled
Transformer Based UPS
Liebert®
GENERAL CATALOGUE
Relia
ble
pow
er fo
r a
sust
aina
ble
wor
ld
4
2) UiTM RembauProject: Delivery & Installation of UPS to UiTM Rembau, Seremban
1) POS MALAYSIAProject: Delivery & Installation of UPSto Pos Malaysia HQ, Daya Bumi,Kuala Lumpur
SERVICES EXPERIENCES
5
3) IKEA, CherasProject: Delivery & Installation of UPS to IKEA Cheras,Kuala Lumpur
4) MyTown, CherasProject: UPS & Installation work to MyTown Shopping Mall, Kuala Lumpur
SERVICES EXPERIENCES
6
5) SPLASHProject: Delivery of UPS & Battery for PLC Controller,Selangor
6) Klinik KesihatanProject: UPS & Installation in Klinik Kesihatan Jenis KK3,Kota Damansara
SERVICES EXPERIENCES
7
8) Kolej Sains Kesihatan Bersekutu Project: Repair and Replace of UPS to Kolej Sains Kesihatan Bersekutu, Johor
7) Melawati MallProject: Delivery of UPS to Melawati Mall, Kuala Lumpur
SERVICES EXPERIENCES
8
9) Hospital Sultan Ismail Project: Delivery and Installation of UPS to HISPAC, Johor
10) CLARIANTProject: Installation of UPS to CLARIANT Factory, Shah Alam
SERVICES EXPERIENCES
9
12) PINEWOOD STUDIO Project: Delivery of Batteries to Iskandar Malaysia Studios Sdn Bhd, Johor
11) MINDEFProject: Delivery of MSB Batteries Jalan Padang Tembak, Kuala Lumpur
SERVICES EXPERIENCES
10
SCHEMATIC DRAWING FOR
PENGURUSAN ASET AIR BERHAD
PROJECT
OWNER
SIGNATURE / CHOP
CONTRACTOR
TITLE
Design By:
Date:
Drawn By:
Checked By:
Approved By:
Drawing No:
SCALE: N.T.S. Sheet No:
30KVA UPSELCB 40A
30A MCCB30A MCCB
30A MCCB
MAINTENANCE BYPASS
250A TPN
MCCB 25KA
R Y B N R Y B N
TN
B S
UP
PLY
Commando Plug
2unit 16A & 2unit 32A
ELCB 40A
Commando Plug
2unit 16A & 2unit 32A
ELCB 40A
Commando Plug
2unit 16A & 2unit 32A
BD
C
A
A. To pull new cable for incoming supply to UPS from existing MCCB input (if necessary)
B. To supply Maintenance Bypass Switch
C. To SUPPLY new-sub DB outgoing supply from 3 phase supply to 1 phase supply
D. To supply new-sub DB for outgoing supply to existing rack system
(via commando socket as stated in Single Line Drawing.pdf)
OUTPUT CableSingle Phase 230V
Commando Cable 32A
Single Phase 230V
Commando Cable 32A
16nos of 12V26AH
Batteries
Extended Battery
Cabinet for 30min
Backup TimeUPS
FRONTUPS BACK
Proposed Rackmount Model PRO806ERLCapacity: 6,000VA/6,000Watts
Single Phase In/ Single Phase Out
Backup Time: 30minutes
6KVA UPS
90
0m
m
60
0m
m
470mm
88mm
780mm
438mm
Sub Distribution Box
3P
MC
CB
/ELR
30
A
3 x
25
mm
2
Backup Formula Sizing
16 x 12 x 26 x 0.5Nos of
BatteriesBatteryAmpere
BatteryRating
BatteryPower Factor
Minutes Backup Time
Equipment Loads4,612Watts
x 60 = 32min
1
2
3
4
5
6
Setting up battery cabinet
Laying batteries
Laying battery cable
Connecting battery bank into UPS
Finish work for batteries cabinet
Overview of UPS with externalbatteries cabinet
+
-
12V 26AH
+
-
12V 26AH
+
-
12V 26AH
+
-
12V 26AH
+
-
12V 26AH
+
-
12V 26AH
+
-
12V 26AH
+
-
12V 26AH
+
-
12V 26AH
+
-
12V 26AH
+
-
12V 26AH
+
-
12V 26AH
+
-
12V 26AH
+
-
12V 26AH
+
-
12V 26AH
+
-
12V 26AH
1ST TIE
R2N
D TIE
R3R
D TIE
R4TH
TIER
BATTE
RY M
CB
60A
42U
41U
40U
39U
38U
37U
36U
35U
34U
33U
32U
31U
30U
29U
28U
27U
26U
25U
24U
23U
22U
21U
20U
19U
18U
17U
16U
15U
14U
13U
12U
11U
10U
09U
08U
07U
06U
05U
03U
04U
02U
01U
UPS FRONT UPS BACK
STANDALONE UPSTotal Loads: 1115Watts & 2012Watts
To proposed Tower type UPS: PRO903WS / 2400WattsCapacity: 3KVA
INP
UT
Ca
ble O
UT
PU
T C
ab
le
Backup Formula
6 x 12 x 9 x 0.6Nos of
BatteriesBatteryAmpere
BatteryRating
BatteryPower Factor
Minutes Backup Time
Equipment Loads2012Watts
x 60 =11min
PROJECT
OWNER
SIGNATURE / CHOP
CONTRACTOR
TITLE
Design By:
Date:
Drawn By:
Checked By:
Approved By:
Drawing No:
SCALE: N.T.S. Sheet No:
Extended
Battery
Cabinet
3 Phase+E 415V
Commando Cable 32A
To Your Load
3 Phase+E 415V
Commando Cable 32A Commando Plug Can Connect Direct
For Future UPS Replacement/Repair/Services
UPS FRONT UPS BACK
External Battery Cabinet
L1L2 L3 N L1 L2 L3 N L1L2 L3 N
Output LineInput
BypassInput
62
0m
m
82
6m
m
470mm
250mm
780mm
592mm
4P ELCB 100A
4 x 25mm2 +16mm2 Ground
4P ELCB 100A
4 x 25mm2 +16mm2 GroundMAINTENANCE
BYPASS SWITCH
OFF
BYPA
SS
UPS Model: PRO83310EL
Capacity: 10,000VA/9,000Watts
3 Phase In/ 3 Phase Out
External Batteries: 20nos 12V26AH
Backup Time: 10mins
10kVA 3/3ph 10 mins backup at full load. Backup Time Formula
20 x 12 x 26 x 0.5
Nos of Batteries
BatteryVolt
BatteryAmpere
Hour
BatteryPower Factor
Minutes Backup Time
Equipment Loads
9,000Watts x 60 = 20min
1ST TIE
R2N
D TIE
R3R
D TIE
R4TH
TIER
BATTE
RY M
CB
60A
+
-
12V 26AH
+
-
12V 26AH
+
-
12V 26AH
+
-
12V 26AH
+
-
12V 26AH
+
-
12V 26AH
+
-
12V 26AH
+
-
12V 26AH
+
-
12V 26AH
+
-
12V 26AH
+
-
12V 26AH
+
-
12V 26AH
+
-
12V 26AH
+
-
12V 26AH
+
-
12V 26AH
+
-
12V 26AH
+
-
12V 26AH
+
-
12V 26AH
+
-
12V 26AH
+
-
12V 26AH
UPS DRAWING/PROPOSAL
PROJECT
OWNER
SIGNATURE / CHOP
CONTRACTOR
TITLE
Design By:
Date:
Drawn By:
Checked By:
Approved By:
Drawing No:
SCALE: N.T.S. Sheet No:
BA
TT
ER
Y
BA
NK
42U
41U
40U
39U
38U
37U
36U
35U
34U
33U
32U
31U
30U
29U
28U
27U
26U
25U
24U
23U
22U
21U
20U
19U
18U
17U
16U
15U
14U
13U
12U
11U
10U
09U
08U
07U
06U
05U
03U
04U
02U
01U
UPS Front42U
41U
40U
39U
38U
37U
36U
35U
34U
33U
32U
31U
30U
29U
28U
27U
26U
25U
24U
23U
22U
21U
20U
19U
18U
17U
16U
15U
14U
13U
12U
11U
10U
09U
08U
07U
06U
05U
03U
04U
02U
01U
UPS System
Battery Pack
INP
UT
Ca
ble
OU
TP
UT
Ca
ble
UPS Back
Proposed UPS Model: PRO801ERL
Capacity: 1,000VA/900Watts
Single Phase In/ Single Phase Out
Backup Time: 30minutes
1KVA UPS RACKMOUNT (30mins)Backup Formula Si�ing
10 x 12 x 9 x 0.5Nos of
BatteriesBatteryAmpere
BatteryRating
BatteryPower Factor
Minutes Backup Time
Equipment Loads900Watts
x 60 = 36min
OUTPUT CableINPUT Cable
20nos of 12V26AH
Batteries
Extended Battery
Cabinet for 30min
Backup Time
UPS FRONT
UPS BACK
Proposed Rackmount Model PRO810ERLCapacity: 10,000VA/9,000Watts
Single Phase In/ Single Phase Out
Backup Time: 30minutes
10KVA rack mountable (Input/output 230V, extended runtime)
90
0m
m
470mm 780mm
Sub Distribution Box
Backup Formula Si�ing
20 x 12 x 40 x 0.5Nos of
BatteriesBatteryAmpere
BatteryRating
BatteryPower Factor
Minutes Backup Time
Equipment Loads9,000Watts
x 60 = 31min
1
2
3
4
5
6
Setting up battery cabinet
Laying batteries
Laying battery cable
Connecting battery bank into UPS
Finish work for batteries cabinet
Overview of UPS with externalbatteries cabinet
1
3
5
7
9
11
13
15
17
19
21
23
25
27
24 port utp patch panel
27U rack
24 portnetwork switch
24 port utp patch panel
cable management
cable management
cable management
cable management
8 port ber patch panel
cable management24 portnetwork switch
24 portnetwork switch
cable management
cable management
24 port utp patch panel
24 port utp patch panel
24 portnetwork switch
cable management
cable management
1ST TIE
R2N
D TIE
R3R
D TIE
R4TH
TIER
BATTE
RY M
CB
60A
+
-
12V 26AH
+
-
12V 26AH
+
-
12V 26AH
+
-
12V 26AH
+
-
12V 26AH
+
-
12V 26AH
+
-
12V 26AH
+
-
12V 26AH
+
-
12V 26AH
+
-
12V 26AH
+
-
12V 26AH
+
-
12V 26AH
+
-
12V 26AH
+
-
12V 26AH
+
-
12V 26AH
+
-
12V 26AH
+
-
12V 26AH
+
-
12V 26AH
+
-
12V 26AH
+
-
12V 26AH