8/7/2019 Broadband Communications over Power Lines
1/23
Broadband Communications
over Power Lines(PLC)
By Marc C. Tarplee, Ph.D. N4UFP
ARRL Technical CoordinatorSC Section
8/7/2019 Broadband Communications over Power Lines
2/23
What is PLC?
8/7/2019 Broadband Communications over Power Lines
3/23
PLC (also known as BPL) is a technique for
sending high speed data through the mediumvoltage power distribution network
The idea of sending data through the power
distribution network is not new
Utilities use LF for network control and telemetry(typically < 0.200 MHz)
Schools have used carrier current system for campus
radio systems that operate in the AM band (0.530
1.700 MHz) What makes BPL different is that it uses
frequencies between 2 and 80 MHz
8/7/2019 Broadband Communications over Power Lines
4/23
8/7/2019 Broadband Communications over Power Lines
5/23
2. Types of PLC
8/7/2019 Broadband Communications over Power Lines
6/23
There are three major categories of PLC:
Access PLC uses electrical distribution lines,overhead or underground, to provide broadbandInternet access to homes and businesses.
This is currently in the developmental stage
In-building PLC uses the electrical wiring within a
building to network computers. Most systems use the HomePlug standard which provides
protection for amateur frequencies
Control PLC operates below 500 kHz, and is usedby electric-utility companies to control their
equipment using the power-lines as transmissionlines.
These systems are not a problem, although it is interesting tonote that utilities successfully lobbied against an amateur VLFallocation, claiming that amateur transmissions could disrupttheir communications.
8/7/2019 Broadband Communications over Power Lines
7/23
3. PLC Modulation Techniques
8/7/2019 Broadband Communications over Power Lines
8/23
Access PLC Access PLC systems are presently under
development. Current systems use OFDM
(orthogonal frequency division multiplexing) in
combination with some type of PSK .
Carrier frequencies can be between 2 and 30
MHz.
No filtering provisions are made to protect otherusers of the HF/VHF spectrum
Data throughput > 10 Mb/sec
8/7/2019 Broadband Communications over Power Lines
9/23
HomePlug HomePlug uses a combination of OFDM
(orthogonal frequency division multiplexing) and
DQPSK (differential quadrature phase shift
keying) to send data through power lines within
the home.
Carrier frequencies are between 4.5 and 21 MHz.
The modem output has notches at 3.5, 7.0, 10.1,14.0, and 18.1 MHz to reduce interference to
amateurs.
Data throughput > 10 Mb/sec
8/7/2019 Broadband Communications over Power Lines
10/23
HomePlug Software in the receiver continuously determines
the transfer function of the medium and carrier
frequencies are changed to use the best available
spectrum.
HomePlug signal power is spread over the entire
4.5 21 MHz bandwidth as the carrier frequencies
are changed.
HomePlug signals can pass through a residential
service entry panel with less than 10 dB loss.
8/7/2019 Broadband Communications over Power Lines
11/23
8/7/2019 Broadband Communications over Power Lines
12/23
Control/Carrier Current PLC These use frequencies below 1.7 MHz.
Carrier current AM signals 0.53 1.70 MHz
LF telemetry/control signals used by utilities
8/7/2019 Broadband Communications over Power Lines
13/23
4. RFI from Access Line PLC
8/7/2019 Broadband Communications over Power Lines
14/23
Tests involving PLC systems in Japan and Europe
indicate that PLC can cause significantinterference to other users of the HF spectrum.
Medium voltage power distribution lines look verymuch like antennas at HF wavelengths.
The next slide shows the far-field pattern of a 328ft (100 m) segment of a typical MV distibutionline. The conductors are at a height of 10m (32 ft10 in) and they are spaced 1.5 m (4ft 5in) apart.
The load is assumed to be the primary of aneighborhood transformer, which is assumed tohave an impedance of 10 j25 ohms.
8/7/2019 Broadband Communications over Power Lines
15/23
Elevation patterns for radiation from MV Power Lines
Perpendicular to Lines Parallel to Lines
28 MHz
14 MHz
7 MHz
3.5 MHz
0.15 MHz
28 MHz
14 MHz
7 MHz
3.5 MHz
0.15 MHz
+9 dBi+5 dBi
8/7/2019 Broadband Communications over Power Lines
16/23
As might be expected, the power lines look like longwire antennas at HF, with some gain and a complexmulti-lobed radiation pattern
It is interesting to note that the signal transmitted fromthe power lines in the LF range (150 kHz) is less than 70 dbi in any direction.
Utilities RFI experience in the LF range is nopredictor of RFI problems in the HF range.
Because overhead power lines run in all directions, theresultant field produced by the entire powerdistribution system should be more or less isotropic inthe azimuthal plane.
ARRL simulations indicate that a fully-deployed accessline PLC system would raise the noise floor by 70 dB
(9 s-units + 16 dB)
8/7/2019 Broadband Communications over Power Lines
17/23
Japanese PLC RFI
Study
Noise Floor
These measurements were made at 7 MHz on a 96
km long path in Japan.
PLC signals raised the noise field strength by 25
dB
8/7/2019 Broadband Communications over Power Lines
18/23
Effect of PLC on HF Coverage
20 m Coverage under
normal conditions
20 m Coverage with access
PLC in neighborhood
> 75%
~ 50%
< 25%
8/7/2019 Broadband Communications over Power Lines
19/23
ARRL PLC Video
8/7/2019 Broadband Communications over Power Lines
20/23
5. RFI from HomePlug PLC
8/7/2019 Broadband Communications over Power Lines
21/23
HomePlug uses a spectral mask that provides 30dB of filtering in the amateur HF bands.
At current RF brightness levels of 80 dBm/Hz,
HomePlug signals can cause interference to
antennas (especially indoor) that run within 2 3
m of household power lines.
HomePlug signals can also leak into other
households with < 10 dB of attenuation, causingproblems for all homeowners sharing a common
transformer.
8/7/2019 Broadband Communications over Power Lines
22/23
6. What Can Be Done?
8/7/2019 Broadband Communications over Power Lines
23/23
The FCC recently closed off comment on the PLC
docket. Hundreds of amateurs did comment on theproblems with PLC during the comment period.
Measurements need to be made. If a utility isdeploying PLC in your area, please make
measurements of the noise. We need to show theFCC what the problems are.
It is very likely that some form of PLC will beimplemented the economic potential is to great.
It is important for amateurs to help steer theimplementation so that our frequencies areprotected