Comparison of 3D deforma ons measured by combined speckle metrology methods with results from numerical simula ons

M. Dekiff1, B. Kemper2, C. Denz3, D. Dirksen1 

1 Department of Prosthe c Den stry and Biomaterials, University of Münster, Waldeyerstr. 30, 48149 Münster, Germany, markus.dekiff@uni‐muenster.de 2 Biomedical Technology Center of the Medical Faculty, University of Münster 3 Ins tute of Applied Physics, University of Münster 

Introduc on Op cal measurement  techniques provide  the necessary  sensi vity  to determine microscopic deforma ons for non‐destruc ve analyses of the mechanical behavior of hard  ssue and bio‐materials.  

Such problems are usually  inves gated numerically by finite element analysis. However,  the valida on  and  op miza on  of  these  simula ons  require  a  comparison  of  numerical  results with measured data.  

The measurement system proposed for this task combines speckle metrology methods for the acquisi on of microscopic and macroscopic 3D deforma ons as well as of macroscopic shape.  

Applica on:  Comparison  of  the  simulated  deforma on  of  a mandible model  due  to mechanical  loading  of  an  inserted  dental  implant with measured data Measurement 

The mandible model is made of photopolymer (Young's modulus: approx 2.7 GPa) using a 3D printer 

The dental implant (diameter: 2.5 mm, length: 9 mm,  tanium, Young's modulus: 105 GPa) is  pro‐vided with a ball abutment.  

A load of 50 N is applied to the top of the implant with a force gauge mounted to a test stand.  

To achieve maximum sensi vity,  the deforma on measurement using ESPI and DSP  is carried out with homogenous  illumina on  (aperture of  the diaphragm  in  front of  camera C3: A1;  sub‐image size: 64 x 64 px; grid spacing: 64 px).  

For 3D shape acquisi on speckles with a diameter of 8.5 px are projected (apertures of cameras C1 and C2: f/4; sub‐image size: 53 x 53 px; grid spacing: 26 px). 

 

Simula on 

Transforma on of  the CAD models of  the mandible model and the implant into the coordinate system of the measure‐ment. This is achieved by best‐fit registra on on the surface determined by 3D shape acquisi on. 

Genera on of a  (second order) tetrahedral mesh using the finite element mesh generator GMSH. 

Finite element analysis (FEA) using the FEA appli‐ca on CalculiX: 

Displacement  boundary  condi on:  no  dis‐placements at the bo om of the model. 

Load: a  load of 50 N  is applied  to  the  top of  the implant (direc on determined photogram‐metrically  based  on  the  direc on  of  transla‐on of the force gauge). 

Projec on  of  the  surface  nodes  into  the  image plane of the camera used for ESPI (camera C3). 

Projec on of the deforma on vectors calculated by  FEA  on  the  direc on  of  the  op cal  axis  and the image plane of camera C3. 

 

 

Results and Discussion 

The method allows  for a direct 3D comparison of FE analysis and measurements and  reveals  the  discrepancies. 

While the shape of the predicted deforma on is in good agreement with observa on, quan ta ve values differ. 

A possible shortcoming of the simula on could be that  in reality,  implant and mandible model do not form a single body as it is assumed in the simula on. Furthermore, the assumed contact point between the  p of the force gauge and the ball abutment may be incorrect. 

Conclusion

The measurement system allows the simultaneous acquisi on of microscopic and macroscopic 3D deforma ons as well as of macroscopic shape. 

The size of speckles projected for simultaneous macroscopic shape and deforma on measurements shows an opposing effect on the performance of ESPI and DSP. Hence, their op mum size depends on the magnitude and direc on of the expected deforma ons. 

The observed differences between simulated and measured deforma ons prove the importance of compara ve measurements. 

References 

[1] M. Dekiff, P. Berssenbrügge, B. Kemper, C. Denz, D. Dirksen: Three‐dimensional data acquisi on by digital correla on of projected speckle pa erns. Applied Physics B, 99(3), 449‐456 (2010) 

[2] T. Fricke‐Begemann,  J. Burke: Speckle interferometry: three‐dimensional deforma on field meas‐urement with a single interferogram. Applied Op cs, 40, 5011–22 (2001)

Experimental Setup Combina on of: 

Photogrammetric  3D  shape  acquisi‐on by digital  image  correla on of a 

projected laser speckle pa ern [1] 

Macroscopic shape  

Macroscopic deforma ons 

Electronic speckle pa ern interferom‐etry  (ESPI) and digital  speckle photo‐graphy  (DSP),  reconstruc on  of  the object wave’s phase and intensity dis‐tribu ons by Fourier‐transform meth‐od [2] 

Microscopic 3D deforma ons  

All 3 methods can be applied simultaneously.  

Op miza on 3D shape acquisi on by digital image correla on of a projected speckle pa ern 

The  precision  is  quan fied  by  measuring  a spherical surface (radius: 15 mm) and determin‐ing  the mean distance of  the measured data  to reference data (best‐fit of 3D data acquired with a GOM Atos fringe projec on system).

Sub‐image  size  in  the  correla on  process: 33 x 33 pixels (px); sub‐image centers on a 10 px grid. 

F‐numbers from 4 to 5.6 and a speckle size of 7‐11 px offer the best compromise between pre‐cision and a high number of successfully  recon‐structed 3D points. 

ESPI 

The quality of the ESPI measurements is char‐acterized  by  the  noise  of  the  wrapped  phase difference distribu on obtained from a ver cally lted  painted metal  plate  (max.  displacement: 

6 µm; approx. 23 phase difference fringes modu‐

lo 2).   The  noise  is  quan fied  by  determining  the standard  devia on  of  the  original  phase  differ‐ence data to smoothed data (sin‐cos‐average fil‐ter with a kernel of 9 x 3 px, applied 30  mes). 

If  speckles  are  projected,  they  should  be small. 

A  large aperture of  the diaphragm  is prefera‐ble.   

 

DSP 

The precision is quan fied by the standard de‐via on  of measured  in‐plane‐displacements  for   a coated metal plate that is translated parallel to the image plane of camera C3. 

 Sub‐image  size  in  the  correla on  process: 64  x  64  px;  sub‐image  centers  on  a  64  px  grid (391 sub‐images per image). 

Larger measurement range  for  larger project‐ed speckles. 

The largest aperture inves gated and project‐ed  speckles  larger  than  5  px  yield  the  lowest standard devia ons. 

Higher  precision  and  larger  measurement range for homogenous illumina on. 

Mean devia on from reference measurement for different f‐numbers (cameras C1, C2) and average sizes of projected speckles.

ESPI phase noise for different average sizes of projected speckles and apertures of the diaphragm in front of camera C3 (for A1 the diameter of the sideband’s circumcircle amounts to nnyquist, for A2 to 0.8 nnyquist, for A3 to 0.6 nnyquist).

Standard devia on of the in‐plane displacement detected with DSP in dependence on the magnitude of the displace‐ment for different apertures (A1, A2, A3: for descrip on, see above) and sizes of projected speckles d.

0.1

1

10

100

1000

1 10 100

stan

dar

d d

evi

atio

n /

µm

displacement / µm

A1, d=3 px

A2, d=3 px

A3, d=3 px

A1, d=17 px

A2, d=17 px

A3, d=17 px

0.3

0.4

0.5

0.6

0.7

0.8

0.9

0 5 10 15 20 25 30

ph

ase

no

ise

/ r

ad

speckle size / px

A1

A2

A3

0.00

0.01

0.02

0.03

0.04

0.05

0 2.5 5 7.5 10 12.5 15

me

an d

evi

atio

n /

mm

speckle size / px

f/2.8

f/4

f/5.6

f/8

f/11

Tetrahedral mesh used for the finite element analysis.

Cross‐sec on through the tetrahedral mesh.

Results of finite element analysis. Results of measurement.