Software rel. 2.3.x
FILLING CHECK VERSION WITH FLOWMETER
2
CONTENTS
● Legendofsymbols.....................................................................................................3INTRODUCTION ............................................................................................................4
Productdescription....................................................................................................4INTENDED USE .............................................................................................................4CONTENT OF THE PACKAGE .....................................................................................4PRECAUTIONS .............................................................................................................4RISKS AND PROTECTIONS BEFORE ASSEMBLY ....................................................5
Positioning..................................................................................................................5Powersupplyandsensorconnection........................................................................5
ASSEMBLY DIAGRAMS ...............................................................................................6CONTROLS IN THE MENU ...........................................................................................7
Firstswitchingon.......................................................................................................7Controlsinthemenu..................................................................................................8Workparameters........................................................................................................9
MENU STRUCTURE ....................................................................................................10PRELIMINARY SETUP FOR USE ............................................................................... 11
Flowratealarms........................................................................................................ 11Sensors....................................................................................................................12Flowmetercalibration...............................................................................................13Language.................................................................................................................15Unitsofmeasurement..............................................................................................16Displaycontrast........................................................................................................17Alarmtones..............................................................................................................18Keytones..................................................................................................................18Valveactivationtime................................................................................................19CANcommunication................................................................................................20Operatingmode.......................................................................................................21Setupmanagement..................................................................................................22Testmenu.................................................................................................................24
USE ..............................................................................................................................27MAINTENANCE / DIAGNOSTICS / REPAIRS ............................................................29
Troubleshooting........................................................................................................29END OF LIFE DISPOSAL ............................................................................................29TECHNICAL DATA ......................................................................................................30
Devicetechnicaldata...............................................................................................30Setupmenu..............................................................................................................31
GUARANTEE TERMS .................................................................................................32
3
● Legendofsymbols
= Genericdanger
= Warning
This manual is an integral part of the equipment to which it refers and must accompany the equipment in case of sale or change of ownership. Keep it for any future reference; ARAG reserves the right to modify product specifications and instructions at any moment and without notice.
4
INTRODUCTION
Productdescription
VISIOisaverycompactandaccuratetop-notchmultifunctiondisplay,abletodisplayanykindofinformationconcerningagriculturaltreatments.Operatorcanselecttherequiredfunctionviasoftware.Itcandisplayseveraltypesofvalues,whichchangeaccordingtosetoperatingmodeandtypeofconnectedsensors.
INTENDED USE
This device is designed towork onagriculturalmachinery for spraying and cropsprayingapplications.ThemachineisdesignedandbuiltincompliancewithENISO14982standard(Electromagneticcompatibility-Forestryandfarmingmachines),harmonizedwith2014/30/UEDirective.
CONTENT OF THE PACKAGE
ThetablebelowindicatesthecomponentsthatyouwillfindintheVISIOpackage:
Legend:
1 VISIO2 Fixingkit3 Instructionmanual (onCD-ROM)4 Installationsheet
PRECAUTIONS
•Donotaimwaterjetsattheequipment.•Donotusesolventsorfueltocleanthecaseoutersurface.•Donotcleanequipmentwithdirectwaterjets.•Complywiththespecifiedpowervoltage(12VDC).•Incaseofvoltaicarcwelding,removeconnectorsfromVISIOanddisconnectthepowercables.•OnlyuseARAGgenuinesparepartsandaccessories.
P o w e r c a b l e ,s e n s o r s a n dconnection cablesto be connectedto VISIO must beorderedseparately.
5
RISKS AND PROTECTIONS BEFORE ASSEMBLY
Allinstallationworksmustbedonewithbatterydisconnected,usingsuitabletoolsandanyindividualprotectionequipmentdeemednecessary.
Positioning
1) Set mounting rail in cabin and fasten it with the relevant screws (1), in a position where VISIO can be easily seen and at hands' reach, but away from any moving organs.2) Secure VISIO to rail and push down until locked in place.3) Fasten wiring so that it does not interfere with any moving parts.
Powersupplyandsensorconnection
Sensorsandpowersupplymustbeinstalledandconnectedbyqualifiedpersonnel.VISIOmustbeexclusivelyconnectedtoARAGequipment.WHENARCWELDINGISREQUIRED,MAKESURETHATEQUIPMENTPOWER IS SWITCHED OFF; DISCONNECT POWER CABLES IF NEEDED.ARAGisnotliablefordamagetothesystem,persons,animalsorpropertycausedbyVISIOwrongorunsuitableassembly.Failuretoobservetheaboveinstructionsautomaticallyvoidsthewarranty.
Wirecolor (powercable) Connectionof
red positive
black negative
green countingabort-groundconnection
yellow countingabort-connection+12VDC
power supplysensors
6
ASSEMBLY DIAGRAMS
+12Vdc
GND
3
1
2
Counting abortGround
connection(green wire)
Counting abortConnection
+12VDC
(yellow wire)
Legend:
1)Powercable2)Pumpstopkit3)Flowmeter4)Powercable-ConnectioncableforBravo300S/400S
STANDARD SYSTEM
SYSTEM WITH RCU
7
CONTROLS IN THE MENU
Firstswitchingon
Atfirstswitchingon,VISIOwillrunaguidedprocedureallowingusertosetthedevice'sbasicsettings.
Press toscrollthroughitems,OKtosaveandmoveontonextsetting,orESCtogobacktoprevioussetting.
WARNING:Beforechangingoperatingmode,makesurethatallsensors/flowmetersareDISCONNECTEDfromthedevice.
8
Controlsinthemenu
Inthefollowingpages,accordingtothesetoperatingmode,somemenuitemscouldslightlydifferfromtheshownones.
SWITCHING ONAPressfor1second;BPressthekeytoviewthevariousvaluesinextendedmode,inasequence(ondisplaycentralpart).Everytimethedeviceisswitchedon,itwillshortlyshowapagewiththenameofdeviceandsoftwareversion.
SWITCHING OFFAPressfor2seconds.
ACCESS TO SETUP MENUFromthemainpage,presskeysatthesametimefor2secondstoopentheSetupMenu.
SELECTION AND ACCESS TO MENU ITEMS
APressafewtimestoscrollthroughitems(selecteditemisindicatedbyablackline);BPresstoopentheselectedmenuitem.
Thethreedotsunderanitemindicatepresenceofanothersetupmenu.
9
EDITING A VALUEAPresstomovethroughdigits;BPressafewtimestoeditthehighlighteddigit;CPresstoconfirm.Thedisplaygoesbacktopreviouspage;DPresstoexitpagewithoutconfirmingmodification.
Editedvaluemustfallwithintherangeshown.
Workparameters
Start ¬
¬
1000.0o
Quantity ¬
¬
Fromthemainpage,presskeyfortwosecondstoopenWorkParametersmenu,andsetvaluesforFlowcorrection.
10
MENU STRUCTURE
Alarms
Min flowrateMax flowrate
Sensors
FlowmeterMan. calibrationAuto calibration
Options
Language
Units of measurem.
Flowrate
VolumelGalm
3
Display contrast
Alarm tones
Keytones
Valve activ. time
l/minGPMm
3/h
Operating mode
Setup management
Save setupLoad setup
Test
CAN communication
Start
Quantity
¬
¬
¬
¬
1000.0o
Firmware versionBattery voltageDisplayKeysSensorsCAN communication *
Fill control (F)
* Menu item active only if CAN communication is active.
11
PRELIMINARY SETUP FOR USE
Flowratealarms
Setminimumandmaximumflowratethresholdsforalarmmessage.
1)OpenAlarmmenu(Setupmenu>Alarms).
Minimumandmaximumflowratealarmsaresetinthesameway.
Thedisplaywillshowthecurrentsettingbelowtheselecteditem.Press OK toedittheselectedmenuitem.
2)Toactivatethealarm,press and
atthesametimeuntilmessage OFF
goesoffandratealarmvalueisdisplayedinstead.Carryoutthesameproceduretodisablealarmagain.3)Setalarmvalue:A)Presstomovethroughdigits.B)Pressafewtimestoeditthehighlighteddigit.C)Presstosavechanges,orD)Presstoquitthepagewithoutconfirmingchanges.
12
Sensors
1)OpenSensorsmenu(Setupmenu>Sensors).
Themenuitemsdisplayedbelowchangeaccordingtothesetoperationmode:whenmoreitemsareavailable,selectthedesiredoneandpressOKtoeditit.
13
Flowmetercalibration
Duetothedifferentsystemconfigurations(tubes,valves,etc.)ratereadingcouldnotbecorrect.Itisthereforerecommendedtoperformasprayingtest.Ifmeasuredvalueisdifferentfromactualvalue,changetherateconstantthroughanautomaticcalibrationprocedureormanuallycalculatetheconstant.
Automatic calibration
Letapreviouslymeasuredquantityoffluidgothroughthesystemoraquantitythatcouldbemeasuredthroughanothersystem.Thehigherthequantityoffluidusedtoperformthecalibrationprocedure,themoreaccuratethecalibration.
1)Openautomaticcalibrationmenu(Setupmenu>Sensors>Flowmeter>AutoCalibration).Assoonasmenuisopen,theequipmentisreadytostartmeasuringwithnofurthercontrolsbeingrequired.2)Startliquidflowinthesystem.Thedisplaywillstartshowingtheincreasingvalueofthemeasuredfluidquantity.Assoonasfluidflowisover,thedisplayedcounterwillstop.
3)NowpressOK.AtthebottomofthedisplayStabilization,messagewillturnonandequipmentwillthenshowthepageontheside.4)Enterpreviouslymeasuredquantityoffluid:A)Presstomovethroughdigits.B)Pressafewtimestoeditthehighlighteddigit.C)Presstocompletethecalibrationprocedure,orD)Pressfor1secondtocancelthecalibrationprocedure.
1 Setting the fluid quantity actually passed through flowmeter during the calibrationprocedure.2 Viewingthefluidquantityreadbyflowmeterduringthecalibrationprocedure.
14
Ifequipmentdoesnotdetectanyflowaftercalibrationisstarted(anddisplayedvalueremains0),pressOKtoquitthecalibrationprocedurewithoutsaving.IfthedevicecontinuestodetectflowafterOKwaspressed,theerrormessageStop flow!.willbedisplayedafterafewseconds.Assoonasflowisstopped,readingwillstabilize,asperstandardprocedure.IncaseVISIOcalculatesavalueoutoftherangethatcanbesetbymeansofthemanualcalibration,thecalculatedvaluewillnotbeset.
Manual calibration
Inordertomanuallysetrateconstant,calculateandsetsuitableconstantusingthefollowingformula:
1)Openmanualcalibrationmenu(Setupmenu>Sensors>Flowmeter>Man.calibration).UnderCalibrationmenu,selectMan.calibration,toviewcurrentlysetconstantvaluebelowtheitem.PressOKtoeditthevalue.
Forflowmeterconstantvalue,refertothecorrespondingmanual.
2)Setflowmeterconstantvalue:A)Presstomovethroughdigits.B)Pressafewtimestoeditthehighlighteddigit.C)Presstosavechanges,orD)Presstoquitthepagewithoutconfirmingchanges.
[quantity measured by equipment]
[actually sprayed quantity]x [constant indicated on flowmeter body]
15
Language
Setthedesiredlanguage.
Options
Language
English
Units of measurem.Display contrast
Openlanguagesettingmenu(Setupmenu>Options>Language).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.
PressOK toeditlanguage.
2 1
2
Language
English
ČeskDeutsch
Español
1)Selectalanguagethrough .
2)PressOK tosave,orESC toquitwithoutsaving.
16
Unitsofmeasurement
Setunitofmeasurementforthevaluesdetectedbythedevice.
Flowrate units of measurement
1)Openinstantrateunitofmeasurementsettingmenu(Setupmenu>Options>Unitsofmeasurem.>Flowrate).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.Press OK toselectflowrateunitofmeasurement.
1)Selectaunitthrough .
2) Press OK tosave,orESC toquitwithoutsaving.
Volume units of measurement
1)Openvolumeunitofmeasurementsettingmenu(Setupmenu>Options>Unitsofmeasurem.>Volume).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.Press OK toselectvolumeunitofmeasurement.
1)Selectaunitthrough .
2) Press OK tosave,orESC toquitwithoutsaving.
17
Displaycontrast
Setdisplaycontrast.
Opendisplaycontrastmenu(Setupmenu>Options>Displaycontrast).
Thedisplaywillshowthecurrentsettingbelowtheselecteditem.PressOK toedittheselectedmenuitem.
1)Setavaluethrough .Everytime
youpressit,valuewillincreaseby5%up
to100%.Usekey todecreasevalue
by5%.2) PressOK tosave,orESC toquitwithoutsaving.
18
Alarmtones
Enable/disablethealarmtones.
Openalarmtonesmenu(Setupmenu>Options>Alarmtones).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.PressOK toedittheselectedmenuitem.
1)Setstatusthrough .
2)PressOK tosave,orESC toquitwithoutsaving.
Keytones
Enable/disablekeytones.
1)Openkeytonesmenu(Setupmenu>Options>Keytones).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.PressOK toedittheselectedmenuitem.
1)Setstatusthrough .
2)PressOK tosave,orESC toquitwithoutsaving.
19
Valveactivationtime
Itispossibletosetfillingvalvetriptime,i.e.thetimefromwhenvalveclosingsignalisoutputandtheactualvalveclosing,sothatVISIOcanaccuratelycalculatetheexactsignaloutputmomentforamoreaccuratefilling.Thevaluetobeenteredisindicatedonthetechnicaldatasheetofthefillingvalveofthesystem.
1)Openvalveactivationtimemenu(Setupmenu>Options>Valveactiv.time).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.Press OK toedittheselectedmenuitem.
2)Setvalveactivationtime:A)Presstomovethroughdigits.B)Pressafewtimestoeditthehighlighteddigit.C)Presstosavechanges,orD)Presstoquitthepagewithoutconfirmingchanges.
20
CANcommunication
FlowrateorlevelvaluescanalsobemeasuredbyconnectingVISIOtoacomputeroftheBravo300SRCUorBravo400Sseries(ASSEMBLYDIAGRAMS).InthiscasedataaresenttoVISIOdirectlybythecomputerRCUthroughtheCANbusconnection.Activatethefunctionasfollows:
Valve activ. time
1)OpenCANcommunicationmenu(Setupmenu>Options>CANcommunication).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.Press OK toedittheselectedmenuitem.
1)Setstatusthrough .
2) Press OK tosave,orESC toquitwithoutsaving.
IfCANcommunicationisactive,thecorrespondingitemwillalsobedisplayedunderthe"Test"Menu.
21
Operatingmode
Setrequiredoperatingmode.
Openoperatingmodemenu(Setupmenu>Options>Operatingmode).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.PressOK tochangetheoperatingmode.
1)Selecttherequiredoperatingmode
through .
2)PressOK tosave,orESC toquitwithoutsaving.
WARNING:OnceOKispressed,thepageontwhesidewillbedisplayed.Beforechangingoperatingmode,makesurethatallsensorsareDISCONNECTEDfromthedevice.PressOKtoconfirmchanges.ConnectthesensorsREQUIREDFORTHE SET OPERATING MODE.
22
Setupmanagement
VISIOsettingscanbeloadedfromorsavedonaUSBpendriveinordertoreconfigureit ifrequired,fixproblemsorsetanotherVISIOwithnoneedtorepeatallmanualoperations.Onceinstallationiscompleted,andVISIOoperationhasbeenchecked,werecommendtosaveallsettingsontoaUSBpendrive.TobeabletousethefollowingfunctionsitisnecessarytoinsertaUSBpendriveintherelevantportatthebottomofVISIO.
1)OpenSetupmanagementmenu(Setupmenu>Setupmanagement).
PressOK toedittheselectedmenuitem.
Load setupAllowstoselectaconfigurationfilesavedintheUSBpendriveandtosetVISIOagain.WARNING:ByloadingtheSETUP.BIN filecontainedintheUSBpendriveontotheVISIO,allcurrentsettingswillbelost.
1)Selectthedesiredcontrolthrough key.2)PressOK toconfirmloading,orESC toquitwithoutsaving.
TheSETUP.BINfilecanbeloadedonlyifitissavedintheUSBpendriverootdirectory.Ifsetupdownloadinvolveschangingoperatingmodeandusingdifferentsensorsthantheonesinuse,makesurethatallsensorsareDISCONNECTEDfromthedevice.PressOKtoconfirmloading.Reconnectsensors.
23
Save setupAllowssavingVISIOconfigurationfileontheUSBpendrive:itwillbepossibletoloaditagainanytimethesamesettingsneedtoberetrieved.
1)Selectthedesiredcontrolthrough
key.2)PressOK toconfirmsaving,orESC toquitwithoutsaving.
IfaSETUP.BINfileisalreadypresentintheUSBpendriverootdirectory,thefilewillbeoverwritten.
24
Testmenu
ThismenuallowsusertoviewsomedataandcarryoutanoperationtestofVISIO:-Firmwareversion:thedisplayshowsthefirmwareversioninstalled.-Batteryvoltage:thedisplayshowsthepowervoltageofthedevice.
Display test
Displaytestchecksthedevicedisplaycorrectoperation.
1)Opendisplaytestmenu(Setupmenu>Test>Display).Press OK toperformthetest.
Allpixelsondisplayareturnedon.PressESCtogobacktopreviouspage.
Keys test
Keystestchecksthedevicekeyscorrectoperation.
Openkeystestmenu(Setupmenu>Test>Keys).
Press OK toperformthetest.
1)Pressanykeyandthecorrespondingdisplayareawillturnon.PressESC toquit:assoonasyouacknowledgetheswitch-ononofthecorrespondingareaonthedisplay,devicewillgobacktopreviouspage.
25
Sensors test
Sensorstestcheckscorrectoperationofthesensorsconnectedtothedevice.
Opensensorstestmenu(Setupmenu>Test>Sensors).
Press OK toperformthetest.
Thedisplaywillshowthecurrentsensorreadingbelowtheselecteditem.1)Severalsensorscouldbedisplayed,dependingonthesetoperatingmode.Inthiscase,selectrequiredsensor
through .
2)PressESCtoquit.
26
CANcommunicationtest
OpenCANcommunicationtest(Setupmenu>Test>CANcommunication).ThedisplayshowsCANcommunicationstatus.
TheCANdeviceshownisonlyanexample.
27
USE
Themainpageshowsthedisplaydividedintothreehorizontalparts:
-toppart:itemStartreferstothekeyonthesidewhichallowsusertostarttheprocedure
( key).
-centralpart:the value is the set filling quantity (in liters).On the side, the symbolois displayed.-bottompart:itemQuantityreferstothekeyonthesidewhichallowsusertosettankfilling
value( key).
1)Press keyfortwosecondstoopen
themenuforsettingthefillingquantity.
2)Setfillingquantity:A)Presstomovethroughdigits.B)Pressafewtimestoeditthehighlighteddigit.C)Presstosavechanges,orD)Presstoquitthepagewithoutconfirmingchanges.
3)Keep keypressedfortwoseconds.Fillingstarts.
28
Thedisplayshowsthefollowingdata:-toppart:setfillingquantity;-centralpart:partialtotalizer;-bottompart:instantflowrate.
Press keyseveraltimestoviewa
valueinextendedmodeuntilrequiredvalueisondisplaycentralpart.
Displayedvaluescannotbeedited.
TankfillingcanbeinterruptedatanytimebypressingESC.Pausemessagewillbeshownatthebottomofthedisplay.PressOKtoresumefilling;pressESCtofinallystopfillinganddisplaywillgobacktoinitialpage.
Whensetquantityisreached,fillingstopsautomatically.Completedmessagewillbeshownatthebottomofthedisplay.
29
MAINTENANCE / DIAGNOSTICS / REPAIRS
•Cleanonlywithasoftwetcloth.•Donotuseaggressivedetergentsorproducts.•Donotcleanequipmentwithdirectwaterjets.
Troubleshooting
FAULT CAUSE REMEDY
VISIOisoffordoesnotswitchon
Nopowersupply Checkpowercableconnections
DeviceisOFF PresstheONkey
VISIOshowswrongdata
Wrongsetup Checkdisplayeddatasetup
Sensorfault ContactthenearestAssistanceCenterVISIOfault
Fillingpump(ifany)doesnotstart
PumpStopModulenotpowered
Checkpowersupplyconnection
END OF LIFE DISPOSAL
Disposeofthesystemincompliancewiththeestablishedlegislationinthecountryofuse.
30
TECHNICAL DATA
Devicetechnicaldata
Description VISIO
Display GraphicLCD,128x64pixels,back-lighting
Powersupplyvoltage 9÷16Vdc
Protectionagainstshort-circuit •
Protectionagainstpolarityinversion •
Max.frequency 1.2KHz
Analoginputs 4÷20mA
Digitaloutput-Maxcurrent 100mA
Maximumpowerinput(withnosensorsconnected) 160mA
Operatingtemperature -20°C÷70°C-4°F÷+158°F
Storagetemperature -30°C÷80°C-22°F÷+176°F
Size 126x79x66mm
Weight 245g
31
Setupmenu
Data Min. Max. Default UoM Notes
Flowmeter Calibration 1 10000 OFF pls/l --
Alarms
Min.flowrate 0.1 1000 OFF l/min. Alarmcanbedisabledbysettingvalueto"OFF"
Max.flowrate 0.1 1000 OFF l/min. Alarmcanbedisabledbysettingvalueto"OFF"
Display Contrast 0 100 50 % --
Options
Language - - English -
Availablelanguages:Italiano,English,Español,Português,Français,Deutsch,Cesky,Polski,Русский,Magyar,ニホン .
Flowrateunitsofmeasurement - - l/min. l/min. Availableunitsofmeasurement:
l/min,GPM,m3/h
Volumeunitsofmeasurement - - l liters Availableunitsofmeasurement:
l,gal,m3
Valveactivationtime 0.0 10 1 sec. --
- Fillingquantity 0.1 50000 1000 l --
32
GUARANTEE TERMS
1. ARAGs.r.l.guaranteesthisapparatusforaperiodof360days(1year)fromthedateofsaletotheclientuser(dateofthegoodsdeliverynote).Thecomponentsoftheapparatus,thatintheunappealableopinionofARAGarefaultyduetoanoriginaldefectinthematerialorproductionprocess,willberepairedorreplacedfreeofchargeatthenearestAssistanceCenteroperatingatthemomenttherequestforinterventionismade.Thefollowingcostsareexcluded:
- disassemblyandreassemblyoftheapparatusfromtheoriginalsystem;- transportoftheapparatustotheAssistanceCenter.2. Thefollowingarenotcoveredbytheguarantee:- damagecausedbytransport(scratches,dentsandsimilar);- damageduetoincorrectinstallationortofaultsoriginatingfrominsufficientor
inadequatecharacteristicsoftheelectricalsystem,ortoalterationsresultingfromenvironmental,climaticorotherconditions;
- damageduetotheuseofunsuitablechemicalproducts,forspraying,watering,weedkillingoranyothercroptreatment,thatmaydamagetheapparatus;
- malfunctioningcausedbynegligence,mishandling,lackofknowhow,repairsormodificationscarriedoutbyunauthorizedpersonnel;
- incorrectinstallationandregulation;- damageormalfunctioncausedbythelackofordinarymaintenance,suchascleaning
offilters,nozzles,etc.;- anythingthatcanbeconsideredtobenormalwearandtear.3. Repairingtheapparatuswillbecarriedoutwithintimelimitscompatiblewiththe
organizationalneedsoftheAssistanceCenter.Noguaranteeconditionswillberecognizedforthoseunitsorcomponentsthathavenotbeenpreviouslywashedandcleanedtoremoveresidueoftheproductsused;
4. Repairscarriedoutunderguaranteeareguaranteedforoneyear(360days)fromthereplacementorrepairdate.
5. ARAGwillnotrecognizeanyfurtherexpressedorintendedguarantees,apartfromthoselistedhere.NorepresentativeorretailerisauthorizedtotakeonanyotherresponsibilityrelativetoARAGproducts.Theperiodoftheguaranteesrecognizedbylaw,includingthecommercialguaranteesandallowancesforspecialpurposesarelimited,inlengthoftime,tothevaliditiesgivenhere.InnocasewillARAGrecognizelossofprofits,eitherdirect,indirect,specialorsubsequenttoanydamage.
6. ThepartsreplacedunderguaranteeremainthepropertyofARAG.7. Allsafetyinformationpresentinthesalesdocumentsregardinglimitsinuse,
performanceandproductcharacteristicsmustbetransferredtotheenduserasaresponsibilityofthepurchaser.
8. AnycontroversymustbepresentedtotheReggioEmiliaLawCourt.
CONFORMITY DECLARATION
The declaration of conformity is available at www.aragnet.com, in the relevant section.
42048 RUBIERA (Reggio Emilia) - ITALYVia Palladio, 5/ATel. +39 0522 622011Fax +39 0522 [email protected]
Only use genuine ARAG accessories or spare parts to make sure manufacturer guaranteed safety conditions are maintained in time. Always refer to the internet address www.aragnet.com
D20
287_
GB
-m04
03/2
017