Industrial Pumps
SL 222 G
KL 5222 F
JL 5222 FV
Mechanical Seal, By-Pass Valve on the cover
Standard Construction, Packing Gland
Standard Construction, Mechanical Seal
N 222 FV
Coupled with gear box, VARMECA speed control unit
PROPERTIES
Inlet/OutletModel
A
GL
FL
B
CL
HL
JL
KL
S
SL
M
ML
N
NL
P
R
Z
ZL
½”
1”
1 ½”
1”
1”
1 ½”
2”
2”
2 ½”
2 ½”
3”
3"
4"
4"
5"
6"
8"
10"
MaximumCapacity
3(m/h)
3.4
7
13.5
25
30
40
45
68
90
125
135
250
340
MaximumSpeed(RPM)
MaximumPressure
(Bar)
1750
900
500
14
400
2.5
PERFORMANCE
1400 7
1
3
6
9300
2
PD Series Internal Gear Pumps
By-pass pressure relief valve can be supplied with•heating jacket for special applications.
Inlet/outlet can be supplied either 90° or 180°.•
www.versapump.comwww.versapump.com
Coupled belt-pulley, ex-proof electricmotor, by-pass valve on the cover
M 5222 FV
Explosed view of Standard Construction
By-pass valve with heating jacket / Cut-away view
GL 122
Direct coupled motor, packing gland
Double jacket, packing gland, by-pass fitted on casing
KL 5462 FW
www.petroland.com.tr3
www.versapump.comwww.versapump.com
VERSA PUMP)
Features :
Exceptional differantial pressure up to 35 bar•High pressure at low capasity•Ability to pump vapour laden liquides (up to 50%)•Low NPSH requirements to prevent cavitation•Self- priming•Modular construction with standardized parts•
Applications :
LPG transfer•LPG Auto Gas Station•Skid Systems•Cylinder filling•Refrigerants•Aerosol propellant•Low density hydrocarbons•Liquids with high vapour pressure•Liquefied gasses•
LPG 50-8 Underground Tank Application
Technical Data :3• Capasity: max. 35 m/h
• Head: max. 35 bar
• Casing pressure: max. 40 bar
• Speed: max. 1750 d/d
• Working temperature: max. 120C
• Flange connections: DIN2501 / Pn40
4
PSC & LPG Series Star Impeller Side Channel Pumps
Liquid List
Fluorocarbons
HCFC 141b
HCFC 142b
HCFC 22
HFC 245 FA
HFC 134 A
HFC 152 A
Isopentane
Cyclopentane
Pentane
Butane
Isobutane
Propan
Hydrocarbons
HFC-12
HFC-22
HFC-134A
HFC-410A
Dimetileter
CO2
Hekzan
Refrigerants Others
www.versapump.comwww.versapump.com
0.1 .2 .3 .4 .5 .6 .7 .8 .91.0 2 3 4 5 6 7 8 910 20 30 40 50 60 70
3M /hr
H(f
t)
H(m
)
1 2 3 4 5 10 20 30 40 50 75 100 125 150 200
350
300
250
200
150
100
50
1200
1100
1000
900
800
700
600
500
400
300
200
100
1000 2000 3000 4000 5000 6000
1450 RPM
GPM
H(f
t)
H(m
)
0.1 .2 .3 .4 .5 .6 .7.8 .91.0 2 3 4 5 6 7 8 9 10 20 30 40 50 60 70
1 2 3 4 5 10 20 30 40 50 75 100 125 150 200
350
300
250
200
150
100
50
1200
1100
1000
900
800
700
600
500
400
300
200
100
1000 2000 3000 4000 5000 6000
1750 RPM
3M /hr
GPM
SERIES 1000 2000 3000 4000 5000 6000
NPSHR ft (m)
Maximum cStViscosity (SSU)
1.6 (.5)– 2 (.6)– 1.6 (.5)– 1.3 (.4)– 1.3 (.4)– 4.6 (1.4)–
13 (4) 3.3 (1) 6.6 (2) 8.2 (2.5) 12 (3.5) 8.2 (2.5)
230 (1050)
Permissible max. vapourladen in the fluid
50%
40 580( )
Minimum Temperature ( )°C °F -40°(-40°)
220° 430°)(
Speed (50Hz)Speed (60Hz)
14501750
Maximum OperatingPressure Bar (psi)
Differantial Pressure ft (m) 50 (15)– 65 (20)– 30 (10)– 30 (10)– 30 (10)– 30 (10)–
690 (210) 1050 (320) 820 (250) 805 (245) 950 (290) 1150 (350)
Stages 1 - 8
Inlet flange size 1/2 (40) 21/2 (65) 21/2 (65) 3 (80) 4 (100) 4 (100)
Outlet flange size 3/4 (20) 1 1/4 (32) 1 1/4 (32) 1 1/2 (40) 2 (50) 2 1/2 (65)
1
Maximum Temperature °C (°F)
Options:
Casing Materials Bearing Materials• Cast Iron • Brass
• Ductile Iron • Bronze
• Stainless Steel • Stainless Steel
Sealing:
• Packing Gland
• Mechanical Seal
• Cartridge Mechanical Seal
• Cartridge Double Mechanical Seal
High Temperature Optionals
• Compensated Clearance
• Bearing material suitable at high
temperature
PSC 3008
Liquid Sensor
www.petroland.com.tr5
LPG 150-6
www.versapump.comwww.versapump.com
Electric motor coupled on base plate.
PM 50
Cartridge mechanical seal.
PM 40
6www.versapump.comwww.versapump.com
www.petroland.com.tr7
PL Series Lobe Pumps
VERSA PUMP PL SERIES pumps have been designed to suit all hygienic pumping
applications found in the food, diary, beverage, pharmaceutical another
places where stainless stell is resistant to liquids to be pumped.
0.05 1.10
0.12 2.64
0.21 4.61
0.41 9.01
0.62 13.63
1.32 25
3.17 40
5.54 50
10.81 50
16.35 65
1 20
1.5 12
2 8
2 12
2.5 8
300 1000
175 800
115 800
175 700
115 700
PLSeries
Model No.
Liters/rev INTGalon/100 rev
mm Inches BAR PSI Rev/min
MaximumSpeed
Standard ConnectionDiameter
Maximum PressureCapacity
2
1
USGalon/ 100 rev
PL 125
PL 140
PL 150
PL 250
PL 265
Double mechanical seal
Type of lobes
Heating jacket on the coverVertical connectionFlange Connection
PROPERTIES
• Unique front-loading product seal positioning gives
faster maintenance , easier cleaning, and less downtime.
• Superior seal cleanliness lengthens seal life and minimizes
seal flaking (product contaminations) and the forward-seal
position places the seals in direct contact with CIP fluids.
• By removing only the front cover, both rotors and product
seals can be fully accessed from the front of the pump
without disconnection the process line.
• Two kinds of gear boxes with three kinds of rotor housings.
• Heating/Cooling jackets easy to fit on the front cover and/or
rotor casing.
• Horizontal ports which can be fitted vertical simply.
• A single seal which can be modified to a double type with a
minimum of additional parts.
• DIN 11851, SMS, Clamp and Flange connection options.
• Handling liquids up to 1,000,000 centipoise , capacity range
up to 26m³/h and head up to 20 Bar.
www.versapump.comwww.versapump.com