OPERATION OF SINGLE ACTING CYLINDER
OPERATION OF SINGLE ACTING CYLINDER
AIM
To operate single acting cylinder using pneumatic.
APPARATUS REQUIRED
1. Single acting cylinder
2. FRL unit
3. Junction box with slide valve
4. 5/2 hand lever operated spring return valve
PROCEDURE
1. Connect FRL to main air supply
2. The various components are connected as per the circuits
3. Block the valve openings if necessary
4. Check the leakage of air and correct it
5. Open the valve and operate cylinder
RESULT
Thus the single acting cylinder is operated.
OPERATION OF DOUBLE ACTING CYLINDER
OPERATION OF DOUBLE ACTING CYLINDER
AIM
To operate double acting cylinder using pneumatic.
APPARATUS REQUIRED
1. Single acting cylinder
2. FRL unit
3. Junction box with slide valve
4.5/2 hand lever operated spring return valve
PROCEDURE
1. Connect FRL to main air supply
2. The various components are connected as per the circuits
3. Block the valve openings if necessary
4. Check the leakage of air and correct it
5. Open the valve and operate cylinder
RESULT
Thus the double acting cylinder is operated.
IMPULSE PILOT OPERATION OF SINGLE ACTING CYLINDER
IMPULSE PILOT OPERATION OF SINGLE ACTING CYLINDER
AIM
To operate a single acting cylinder using pilot operation.
APPARATUS REQUIRED
1. Single acting cylinder
2. FRL unit
3. Junction box with slide valve
4.5/2 external pilot operated spring return valve
5. Push button valve
PROCEDURE
1. Connect FRL to main air supply
2. The various components are connected as per the circuits
3. Block the valve openings if necessary
4. Check the leakage of air and correct it
5. Open the valve and operate cylinder
RESULT
Thus the impulse pilot operation of single acting cylinder is operated.
OPERATION OF SINGLE ACTING CYLINDER CONTROLLED FROM DIFFERENT POSITIONS USING SHUTTLE VALVE
OPERATION OF SINGLE ACTING CYLINDER CONTROLLED FROM DIFFERENT POSITIONS USING SHUTTLE VALVE
AIM
To operate a single acting cylinder controlled from different positions using shuttle valve.
APPARATUS REQUIRED
1. Single acting cylinder
2. FRL unit
3. Junction box with slide valve
4.5/2 external pilot operated spring return valve
5. Push button valve
6. Shuttle valve
PROCEDURE
1. Connect FRL to main air supply
2. The various components are connected as per the circuits
3. Block the valve openings if necessary
4. Check the leakage of air and correct it
5. Open the valve and operate cylinder
RESULT
Thus the single acting cylinder is controlled from different positions using shuttle valve.
OPERATION OF DOUBLE ACTING CYLINDER USING MEMORY VALVE
OPERATION OF DOUBLE ACTING CYLINDER USING MEMORY VALVE
AIM
To operate a double acting cylinder using memory valve
APPARATUS REQUIRED
1. Double acting cylinder
2. FRL unit
3. Junction box with slide valve
4.5/2 external pilot operated spring return valve
5. Push button valve
6. Flow control valve
PROCEDURE
1. Connect FRL to main air supply
2. The various components are connected as per the circuits
3. Block the valve openings if necessary
4. Check the leakage of air and correct it
5. Open the valve and operate cylinder
RESULT
Thus the to operate a double acting cylinder using memory valve
CONTROLLING THE SPEED OF DAC USING METERING IN VALVE
CONTROLLING THE SPEED OF DAC USING METERING IN VALVE
AIM
To control the speed of DAC using METERING IN valve
APPARATUS REQUIRED
1. FRL unit
2. Junction box with slide valve
3. 5/2 hand lever operated spring return valve
4. Double acting cylinder end position cushioning adjustable on one end
5. Flow control valve
PROCEDURE
1. Connect FRL to main air supply
2. The various components are connected as per the circuits
3. Block the valve openings if necessary
4. Check the leakage of air and correct it
5. Open the valve and operate cylinder
RESULT
Thus the speed of DAC using METERING IN valve is controlled
AUTOMATIC OPERATION OF DOUBLE ACTING CYLINDER IN SINGLE CYCLE USING LIMIT SWITCH AND MEMORY VALVE
AUTOMATIC OPERATION OF DOUBLE ACTING CYLINDER IN SINGLE CYCLE USING LIMIT SWITCH AND MEMORY VALVE
AIM
To operate automatic operation of double acting cylinder in single cycle using limit switch and memory valve.
APPARATUS REQUIRED
1. Double acting cylinder
2. FRL unit
3. Junction box with slide valve
4. 5/2 double external pilot operated valve
5. 3/2 roller lever operated valve with spring return
6. Limit switch
7. Memory valve
PROCEDURE
1. Connect FRL to main air supply
2. The various components are connected as per the circuits
3. Block the valve openings if necessary
4. Check the leakage of air and correct it
5. Open the valve and operate cylinder
RESULT
Thus the double acting cylinder in single cycle using limit switch and memory valve is operated automatically
AUTOMATIC OPERATION OF DOUBLE ACTING CYLINDER IN MULTI CYCLE USING LIMIT SWITCH AND MEMORY VALVE
AUTOMATIC OPERATION OF DOUBLE ACTING CYLINDER IN MULTI CYCLE USING LIMIT SWITCH AND MEMORY VALVE
AIM
To operate automatic operation of double acting cylinder in multi cycle using limit switch and memory valve.
APPARATUS REQUIRED
1. Double acting cylinder
2. FRL unit
3. Junction box with slide valve
4. 5/2 double external pilot operated valve
5. 3/2 roller lever operated valve with spring return
6. Limit switch
7. Memory valve
PROCEDURE
1. Connect FRL to main air supply
2. The various components are connected as per the circuits
3. Block the valve openings if necessary
4. Check the leakage of air and correct it
5. Open the valve and operate cylinder
RESULT
Thus the double acting cylinder in single cycle using limit switch and memory valve is operated automatically
PNEUMATIC SEQUENTIAL OPERATION A+B+A-B-
PNEUMATIC SEQUENTIAL OPERATION A+B+A-B-
AIM
To operate DAC in A+ B+A-B- sequence using pneumatic
APPARATUS REQUIRED
1. Double acting cylinder
2. FRL unit
3. Junction box with slide valve
4. Double solenoid pilot operated valve
5. Switch mode power supply
6. Flow control valve
PROCEDURE
1. Connect FRL to main air supply
2. The various components are connected as per the circuits
3. Block the valve openings if necessary
4. Check the leakage of air and correct it
5. Connect as per the circuits
6. Open the valve and operate cylinder
RESULT
Thus the DAC in A+B+A-B- sequence is operated using pneumatic unit
PNEUMATIC SEQUENTIAL OPERATION A+B+B-A-
PNEUMATIC SEQUENTIAL OPERATION A+B+B-A-
AIM
To operate DAC in A+ B+B-A- sequence using pneumatic
APPARATUS REQUIRED
1. Double acting cylinder
2. FRL unit
3. Junction box with slide valve
4. Double solenoid pilot operated valve
5. Switch mode power supply
6. Flow control valve
PROCEDURE
1. Connect FRL to main air supply
2. The various components are connected as per the circuits
3. Block the valve openings if necessary
4. Check the leakage of air and correct it
5. Connect as per the circuits
6. Open the valve and operate cylinder
RESULT
Thus the DAC in A+B+B-A- sequence is operated using pneumatic unit
OPERATION OF DOUBLE ACTING CYLINDER USING SINGLE SOLENOID VALVE
OPERATION OF DOUBLE ACTING CYLINDER USING SINGLE SOLENOID VALVE
AIM
To operate double acting cylinder using single solenoid valve .
APPARATUS REQUIRED
1. Double acting cylinder
2. FRL unit
3. Junction box with slide valve
4. 5/2 way single solenoid pilot operated valve with spring return valve
5. Flow control valve
PROCEDURE
1. Connect FRL to main air supply
2. The various components are connected as per the circuits
3. Block the valve openings if necessary
4. Check the leakage of air and correct it
5. Open the valve and operate cylinder
RESULT
Thus the double acting cylinder using solenoid valve is operated.
OPERATION OF DOUBLE ACTING CYLINDER USING DOUBLE SOLENOID VALVE
OPERATION OF DOUBLE ACTING CYLINDER USING DOUBLE SOLENOID VALVE
AIM
To operate double acting cylinder using double solenoid valve .
APPARATUS REQUIRED
1. Double acting cylinder
2. FRL unit
3. Junction box with slide valve
4. 5/2 way double solenoid pilot operated valve with spring return valve
5. Flow control valve
PROCEDURE
1. Connect FRL to main air supply
2. The various components are connected as per the circuits
3. Block the valve openings if necessary
4. Check the leakage of air and correct it
5. Open the valve and operate cylinder
RESULT
Thus the double acting cylinder using double solenoid valve is operated.
MULTI CYCLE OPERATION OF DOUBLE ACTING CYLINDER
MULTI CYCLE OPERATION OF DOUBLE ACTING CYLINDER
AIM
To operate double acting cylinder by multi cycle operation.
APPARATUS REQUIRED
1. Single acting cylinder
2. FRL unit
3. Junction box with slide valve
4.5/2 hand lever operated spring return valve
PROCEDURE
1. Connect FRL to main air supply
2. The various components are connected as per the circuits
3. Block the valve openings if necessary
4. Check the leakage of air and correct it
5. Open the valve and operate cylinder
RESULT
Thus the double acting cylinder is operated.
OPERATION OF SINGLE ACTING CYLINDER USING PLC
OPERATION OF SINGLE ACTING CYLINDER USING PLC
AIM
To operate single acting cylinder using pneumatic.
APPARATUS REQUIRED
5. Single acting cylinder
6. FRL unit
7. Junction box with slide valve
8. 5/2 hand lever operated spring return valve
PROCEDURE
6. Connect FRL to main air supply
7. The various components are connected as per the circuits
8. Block the valve openings if necessary
9. Check the leakage of air and correct it
10.Open the valve and operate cylinder
RESULT
Thus the single acting cylinder is operated.
OPERATION OF DOUBLE ACTING CYLINDER USING PLC
OPERATION OF DOUBLE ACTING CYLINDER USING PLC
AIM
To operate double acting cylinder using pneumatic.
APPARATUS REQUIRED
1. Single acting cylinder
2. FRL unit
3. Junction box with slide valve
4.5/2 hand lever operated spring return valve
PROCEDURE
1. Connect FRL to main air supply
2. The various components are connected as per the circuits
3. Block the valve openings if necessary
4. Check the leakage of air and correct it
5. Open the valve and operate cylinder
RESULT
Thus the double acting cylinder is operated.