Notifier ONYX Fire Alarm SystemNotifier ONYX Fire Alarm System
2
AgendaAgenda
Company Profile Systems Construction NCS Network Control System NFS-3030 Fire Alarm System Family of Detectors & Modules Advantages features
3
A Company with an Outstanding Heritage and a Tradition of Leadership
1987
Founded 1851 Sold Honeywell
2003
Founded 1949 Sold to Pittway 1987
1984
Founded 1952
Sold to Pittway 1984
1998
Founded 1966
Sold to Pittway 1999
1999
Founded 1976 Sold to Pittway
1998
2003 Sold to Honeywell
Founded in 2003
2003
2000
History
1962
Founded
4
Seven Business Units
Worldwide
Worldwide Leading Commercial Fire Brands
MarketingOperationsEngineering
Customer OperationsCorporate
CommunicationsSix Sigma
Quality
5
EuropeNOTIFIER Burgess Hill, UKNOTIFIER Benelux, France NOTIFIER SwedenNOTIFIER Hilden, GermanyNOTIFIER Barcelona, SpainNOTIFIER Milan, ItalyNOTIFIER RussiaKAC Reddich, UKSSD Horsham, UKSSD Moscow, RussiaSSD Trieste, Italy
North AmericaNOTIFIER Vancouver NOTIFIER TorontoNOTIFIER QuebecNOTIFIER Northford, CTSSD TorontoSSD St. Charles, ILNESCO Atlanta, GAFire-Lite Northford, CTGamewell Northford, CTFCI Northford, CTSilent Knight Minneapolis, MN
Latin AmericaNOTIFIER Mexico
NOTIFER Brazil
NOTIFIER Chile
SSD Juarez, Mexico
Middle East/AfricaNOTIFIER Amman, JordanNOTIFIER South Africa
AustraliaNOTIFIER MelbourneNOTIFIER BrisbaneNOTIFIER Sydney
Far EastNOTIFIER BombayNOTIFIER BeijingNOTIFIER ShanghaiNOTIFIER Hong KongNOTIFIER SingaporeNOTIFIER TaiwanFCI ShanghaiSSD New DelhiSSD Xian, China
Worldwide Operations
6
Product Designed to Satisfy Local Requirements
Product Designed to Satisfy Local Requirements
UL, FM
ULC
CNTC
SSL
EN54, LPC, VDS⌠GOST
IRAM
KIS
CNS
Worldwide OperationsWorldwide Operations
7
Fire Contractor
User
Notifier
MainContractor
NotifierEngineered
SystemDistributors
O.E.M.Johnson Controls, Viking,
Chemetron, Ansual
Fire Contractor
MainContractor
User
8
NOTIâ˘FIREâ˘NET V.5NOTIâ˘FIREâ˘NET V.5
Support 103 Network Nodes
Nodes could be: - NFS-3030 NFS-640 NCA NCS And legacy product
Support 201,960 Addressable Points
9
NOTIâ˘FIREâ˘NET V.5NOTIâ˘FIREâ˘NET V.5
ARCNET Topology Token Passing Non-
collision Protocol Peer to Peer Network
Operation Communication
Speed 312.5 Kbps CCBE â Cooperative
Control by Event
10
NOTIâ˘FIREâ˘NET V.5NOTIâ˘FIREâ˘NET V.5
Support NFPA Network Style 4 and Style 7
Support wire, fiber and mixed wire and fiber communication
Node to node distance By Wire 914.4 m By Fiber 8 db loss (~2.2
km) Distance can be
extended by repeater RPT-W, -F, W/F
11
NCS Network Control SystemNCS Network Control System The Onyx SeriesThe Onyx Series
NCS Intelligent Fire Workstation Run on Windows 2000 operating
systems Traditional Chinese options 30,000+ floor plans graphics Key map Auto-vectoring
12
The Onyx SeriesThe Onyx Series
Full system information access
Operate systems devices, e.g. disable/enable devices, on/off devices
Upload and download panel database 5 panels each time
13
The Onyx SeriesThe Onyx Series
100 operators login, each with unique password and access level
History file filter Built in graphics icon Support Event printer
and graphic printer Support voice files
14
NFS-3030 Fire Alarm System NFS-3030 Fire Alarm System
NFS-3030 NFS-3030
Support 1 to 10 loops 159 intelligent detector
points & 159 module points per loop
Total 3180 points per panel
15
Software ZonesSoftware Zones
1000 General zones Simplified linking of inputs to outputs.
1000 Logic zones Allows conditional I/O linking such as
AND, OR, NOT, ANYx. 10 Releasing zones 100 Trouble zones
16
Traditional Chinese LCD DisplayTraditional Chinese LCD Display
Notifier Advantages Chinese operator interface Chinese event display (120
Chinese characters) Chinese printing direct
from panel Chinese custom action
message (100 messages)
17
ăä¸ć饯示ĺšďźŹďźŁďź¤ăä¸ć饯示ĺš
18
Active Event CountersActive Event CountersActive Event CountersActive Event Counters
確čŞçŤç˝čŚĺ ąäşć¨çĄĺĄľĺŽ¤ A ĺďźŚďźĄďź˘ćŁ Z005 ć˘ć¸Źĺ¨ ( ĺ éť ) 9:55:24A FRI SEP 06, 2002 L01D126 9:56:25A FRI SEP 06, 2002 çŤčŚ :001 é čŚ :000 ć é :005 çŁčŚ :000 äżĺŽ :000 çŚč˝ :000
ĺ śĺŽčłč¨çˇ¨ç¨ / çć ćščŽ 丝é¸ĺŽ Determine priorities and number of events at
a glance.
19
Custom Action MessageCustom Action MessageCustom Action MessageCustom Action Message
çŤčŚćčŤééŁçľĄĺ¤ĺä¸ĺż :2298-1234 ćśé˛é :2256-1119
Each device can be linked to 1 of 100 messages Each message allows up to 45 characters (3 rows x
15 characters) to provide clear instruction related to the event
20
Programming OptionsProgramming Options
Veri-Fire Tools. Create and
backup programs in the comfort of the office.
Test and compare programs.
Communicate with all network panels from any network location.
21
Advanced TechnologyAdvanced Technology
Flash memory...no need to change EPROM's. Customers can receive upgrades via
modem or web. Reduces cost of labor and parts.
Database signature protection. Prevents accidental data loss.
22
Family of Detectors & ModulesFamily of Detectors & Modules Advanced Detectors Advanced Detectors
Photoelectric Smoke Detector (FSP-851) Ionization Smoke Detector (FSI-851) Heat Detector (FST-851 / FST-851R / FST-851H) Acclimate PLUS TM Multi-sensor Detector (FAPT-851) High Sensitivity Laser Detector (FSL-751) HARSH Detector (FSH-751) Intrinsically Safe Smoke and Heat Detector (1151EIS and 5451EIS) Beam Detector (FSB-200)
23
Detector BaseDetector Base
B501 Detector Base 4â B501PB Detector Base 4âX 10 pcs B710LP Detector Base 6â B710LPPB Detector Base 6âX 10 pcs B224BI Isolator Base B224BH Sounder Base B224RB Relay Base B710HD Base for HARSH B401 Base for 1151EIS, 5451EIS
24
FlashScan⢠SpeedFlashScan⢠Speed
FlashScan Protocol Groups and Scans 10 Devices at a Time Significantly Improves Response
Time Reports an Alarm within 1 Second Turns on All Outputs within 2
Seconds
FlashScan Request D1 D2 D3 D5D4 D6 D7 D8 D9 D10
Analog data from 10 devices at a time
25
Includes FlashScanâ˘Includes FlashScanâ˘
26
Acclimate Plus Acclimate Plus TMTM
Microprocessor based Analog intelligent
design Dual bi-color LEDs
Flashes green when normal
Steady red on alarm Separate head and
base Multiple base options
(ISO / Relay / Sounder )
27
HARSH⢠HARSHâ˘
Standard commercial photoelectric sensor.
Integral fan to draw air into the sensing chamber.
Two 32 micron filters to filter out dust, lint, grime and steam.
Filters are supervised for loading and replaceable.
28
HarshHarshTMTM
29
30
VIEW⢠Very Early Warning VIEW⢠Very Early Warning DetectionDetection
Uses an extremely bright, controlled laser
Obscuration to .02%/ Ft. Light is transmitted
through the chamber When the light is
scattered (smoke) the light reflects
off the mirror to the photo diode
Application: Critical Environments
31
What are the best locations for the What are the best locations for the Beam?Beam?
Areas with high ceilings Atria Churches
Large open areas Warehouses Manufacturing
facilities Garages
Mount detector on stable mounting surface
32
Operating AdvantagesOperating Advantages
16 to 328 ft. protection range Accommodates both short- and
long-range applications Long-range reflector kit
available
12 & 24 V operating range
-22°F to 131°F operating temperature range Ideal for garages, warehouses,
barns, etc.
33
Intrinsically Safe DetectorIntrinsically Safe Detector
5451 EIS is UL approved as a heat detector 1451 EIS is UL approved as a smoke detector FM approved for use in
Class A,B,C,D hazardous (classified) locations BASEEFA approved for use in EEX ia IIC T5
hazardous locations Two LEDs provide 360o visibility Build-in tamper-resistant feature SEMS screws for easy wiring Low standby current
34
FMM-1 Class A/B Monitor Module
FMM-101 Class B Mini Monitor Module
FDM-1 Dual Monitor Module
FZM-1 Smoke Detector Interface Module
FCM-1 Class A/B Control Module
FRM-1 Relay Module ISO-X Isolator Module
FlashscanFlashscanÂŽÂŽ Modules Modules
35
New Multi-I/O ModulesNew Multi-I/O Modules
XP10-M Ten Class B circuits
36
New Multi-I/O ModulesNew Multi-I/O Modules
XP6-C Six Class B or three
Class A circuits
37
New Multi-I/O ModulesNew Multi-I/O Modules
XP6-R Six SPDT relays
2A @ 30Vdc
38
Advantages featuresAdvantages features
Flash Scan ModeFlash Scan Mode
Twice the Information LED Color Control Blink control and pattern generation
Walk Test indicates Device Address Address 23 = 2 Blinks, Pause, Three Blinks
Reverse Compatible Mix Previous Technology Sensors with
FlashScan Devices Entire Loop must be FlashScan to Benefit
from Protocol Advantages
39
AWACS⢠ApplicationAWACS⢠Application
Drift Compensation Maintenance Warning â Three Levels Detector Sensitivity Settings Cooperative Multi-Detector Sensing
40
AWACS⢠Software Algorithms AWACS⢠Software Algorithms Drift CompensationDrift Compensation
AnalogAnalogReadinReadingg
Time (Months)Time (Months)
with compensationwith compensation
without compensationwithout compensation
Alarm LevelAlarm Level
41
Three Maintenance AlertsThree Maintenance Alerts
0
0.005
0.01
0.015
0.02
0.025
0.03
0.035
0.04
0.045
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
Adjustment Periods
Ch
am
be
r V
alu
e
Upper Chamber Threshold
Lower Chamber Threshold
Maintenance Alert
Low Chamber Value
Maintenance Urgent
42
AWACS⢠Sensitivity LevelsAWACS⢠Sensitivity Levels
0.0%
0.5%
1.0%
1.5%
2.0%
2.5%
3.0%
3.5%
1 - (Hospital)2 - (Schools)
4 - (Office)
6 - (Mercantile)7 - (Industrial)
5 - (Residential)
8 - (Laundry)9 - (Process Plant)
3 - (Theater)CLEAN
DIRTY
Alarm Too Quickly
Alarm Too Slowly
âCleanâ vs. âDirtyâ Environments
43
AWACS⢠AlgorithmsAWACS⢠Algorithms
Self-Optimizing Pre-alarm. Reduces false pre-alarms due to
spikes. Patented Drift Compensation
algorithm (US patent 5,764,142). Meets the individual sensor
calibration testing requirements of NFPA-72.
44
AWACS⢠AlgorithmsAWACS⢠Algorithms
Exclusive cooperative multi-sensor. Allows the signals from up to three
sensors to be combined to make the fire decision.
Adds âdistanceâ to the equation.Smoke acts like a gas and will evenly
disperse. Increased response to uniformly
distributed smoke.Sampling over a wider area is more
stable.Reject isolated sources of false signals.
45
Application ChallengeApplication Challenge
An Elevator Lobby
D001 D002 D003D004D005
Group 1Group 1
Group 2
Very stable against spurious single source smoke, but reacts
almost twice as fast to uniform smoke from a real fire!
Group 1 Sensitivity = (D12+D22+D32)1/2 / 3
46
80% Alarm Level
Cooperative Sensor DetectionCooperative Sensor Detection
Photo Sees Smoke, but the IonsDo Not Due to the
Critical Element of Distance! The Spurious Alarm Is Avoided.
Ion Photo Ion
Cooperating Sensors
47
Incipient SmokeIncipient Smoke
Because Each Sensor Sees Uniform Distributionof Smoke an Alarm Is Generated, Even Though
There Is Not Enough Smoke to Set off Any Individual Sensor on its own!
Ion Photo Ion
Cooperating Sensors
58% Smoke
48
49
AWACS⢠AlgorithmsAWACS⢠Algorithms
Alarm Verification. Prevents false alarms by ignoring
momentary peak or spurious values. Insures the presence of a ârealâ
alarm by rechecking the chamber values.
50
Weekly Occupancy ScheduleWeekly Occupancy Schedule
Permits detector sensitivity change by time of day, day of week and/or preset holiday schedule. Enhances ability to avoid false
alarms based on occupancy. Provides ability to increase
sensitivity when building is not occupied.
51
Example: A Restaurant / BarExample: A Restaurant / Bar
0.0%
0.5%
1.0%
1.5%
2.0%
2.5%
12:0
0 A
M
1:00
AM
2:00
AM
3:00
AM
4:00
AM
5:00
AM
6:00
AM
7:00
AM
8:00
AM
9:00
AM
10:0
0 A
M
11:0
0 A
M
12:0
0 P
M
1:00
PM
2:00
PM
3:00
PM
4:00
PM
5:00
PM
6:00
PM
7:00
PM
8:00
PM
9:00
PM
10:0
0 P
M
11:0
0 P
M
Time of Day
Bac
k-G
rou
nd
Ob
scu
rati
on
The solution is to adjust the sensitivity based on occupancy