Cenov ponuka
Zkaznk: Slovensk technick univerzita v Bratislave ELVAC SK s. r. o.Vazovova 5, 812 43 Bratislava Zlatovsk 27
911 01 TrennTel.: 032-640 1766Fax: 032-640 1766
Kalkulciu previedol: Peter Hladk Mail: [email protected]: 421 911 280 934Mail: [email protected] IO: 36 344 575
I DPH: SK2022007317
Poloka Nzov ks Kusov cena (EUR) Cena celkovo (EUR)
C.1.1.1. NI PXI-1042 8-slot 3U asi s univerzlnym AC napjacm adaptrom 1 1 922,00 1 922,00
C.1.1.2. Riadiaci pota NI PXI-8115 Core i5-2510E 2.5 GHz, Kontrolr, OS Win 7 32-bit 1 3 866,00 3 866,00
C.1.2.1. NI PXI-4072 6 Digit FlexDMM & LCR meter (1.8 MS/s Digitizr, 100nV-300V, 1 2 534,00 2 534,00
10nA-1A, 2-yr cal)
C.1.2.2. NI PXI-4071 7 Digit FlexDMM (1.8 MS/s Digitizr, 10nV-1000V, 1pA-3A, 2-yr cal) 1 2 821,00 2 821,00C.1.2.2. NI PXI-4071 7 Digit FlexDMM (1.8 MS/s Digitizr, 10nV-1000V, 1pA-3A, 2-yr cal) 1 2 821,00 2 821,00
C.1.2.3. NI PXI-6229, M sria DAQ (32 analgovch vstupov, 48 digitlnych I/O, 4 analgov 1 989,00 989,00
vstupy) s NI-DAQmx driver software
C.1.2.4. NI PXI-5152, 2 GS/s, 300 MHz Digitizr w/256 MB/ch pam na doske 1 9 615,00 9 615,00
C.1.2.5. NI PXI-5422, 200 MS/s signlny genertor W/LVDS vstup, 16-bit, 256MB 1 11 067,00 11 067,00
(32x dlh playback vs 8MB) vrtane NI Analog Waveform Editor
Cena bez DPH v EUR: 32 814,00
6 562,80
Cena s DPH v EUR: 39 376,80
Poznmka:Ceny s vrtane poplatku do RF a autorskho poplatku LITA. K danm produktom poskytujeme i technick support.
DPH 20%:
ELVAC SK s.r.o. Zlatovsk 27, 911 01 Trenn Slovensk republika
tel.: +421 32 640 1766 fax: +421 32 640 1766
I: 36344575 DI: SK2022007317 Bankov spojenie: 0275553333/0900 Oddiel: Sro, Sloka slo: 15689/R
Vec: estn prehlsenie
estne prehlasujeme e:
Nie je, ani nebol tatutrny orgn, ani len tatutrneho orgnu prvoplatne odsden za trestn in korupcie, za trestn in pokodzovania finannch zujmov Eurpskych spoloenstiev, za trestn in legalizcie prjmu z trestnej innosti alebo za trestn in zaloenia, zosnovania a podporovania zloineckej skupiny,
nie je, ani nebol tatutrny orgn, ani len tatutrneho orgnu prvoplatne odsden za trestn in, ktorho skutkov podstata svis s podnikanm,
nie je, ani nebolo voi nemu veden konkurzn konanie, nie je v konkurze, v likvidcii, ani nebol proti nemu zamietnut nvrh na vyhlsenie konkurzu pre nedostatok majetku,
nemme evidovan nedoplatky na zdravotn poistenie, socilne poistenie a prspevkov na starobn dchodkov sporenie, ktor sa vymhaj vkonom rozhodnutia,
nemme evidovan daov nedoplatky, ktor sa vymhaj vkonom rozhodnutia, sme oprvnen dodva tovar, poskytova slubu, neporuili sme v predchdzajcich piatich rokoch zkaz neleglneho zamestnvania poda osobitnho
predpisu, nedopustili sme sa zvanho poruenia odbornch povinnost v predchdzajcich piatich rokoch,
ktor vie verejn obstarvate a obstarvate preukza.
V Trenne da 12.06. 20113
Ing. Michal Gajdek konate
Podprahov zkazka obstarvan poda 99 zkona . 25/2006 Z.z. o verejnom obstarvan a o zmene a doplnen niektorch
zkonov v znen neskorch predpisov
Prloha .2.
Identifikan daje uchdzaa
(Dotaznk uchdzaa)
Zkazka
KPA MODULRNEHO MERACIEHO SYSTMU NA BZE PXIe/PXI
Obchodn meno/nzov: ELVAC SK s.r.o.
Adresa sdla uchdzaa: Zlatovsk 27, 911 01 Trenn
Zastpen3: Ing. Gajdek Michal
Registrovan: 23. 05. 2005
IO: 36344575
DI: 2022007317
I DPH: SK2022007317
Bankov spojenie: Slovensk sporitea, a. s.
slo tu: 0275553333/0900
ABO, IBAN + SWIFT4: GIBASKBX
Kontaktn osoba: Hladk Peter
Telefn: +4210326440766
Fax: +4210326440766
e-mail: [email protected]
V........Trenne...........da.......12.06. 2013 ______________________________________________
Meno, priezvisko a podpis tatutrneho zstupcu uchdzaa
_______________________________
3 tatutrny zstupca resp. zstupcovia
4 dopln uchdza so sdlom mimo zemia Slovenskej republiky
KPA MODULRNEHO MERACIEHO SYSTMU NA BZE PXIe/PXI
projekt: Zvyovanie energetickej bezpenosti SR, ITMS: 26220220077
Podprahov zkazka obstarvan poda 99 zkona . 25/2006 Z.z. o verejnom obstarvan a o zmene a doplnen niektorch
zkonov v znen neskorch predpisov
Prloha .1.
F. PRLOHY K SANM PODKLADOM
KRITRI NA VYHODNOTENIE PONK
zkazky KPA MODULRNEHO MERACIEHO SYSTMU NA BZE PXIe/PXI
(Formulr ponuky k dtumu predkladania ponk)
1. Zkladn daje
Nzov, obchodn meno uchdzaa (obchodn meno uvete rovnako vo vetkch formulroch)
ELVAC SK s.r.o.
Adresa sdla uchdzaa Ulica . Zlatovsk 27
Obec Trenn
PS 911 01
Kontaktn osoba uchdzaa (uvete kontaktn daje osoby poverenej zastupova uchdzaa)
Meno Peter
Priezvisko Hladk
Titul
Funkcia obchodnk
2. Cena obstarania predmetu zkazky v EUR
P. . Nzov poloky Kritrium
CENA v EUR bez DPH
Sadzba DPH platn pre
SR
Suma DPH v EUR
CENA v EUR s DPH
1.
Modulrny merac systm na bze PXI
Najniia cena v EUR bez DPH
32 814,00
20%
6 562,80
39 376,80
Cena celkom za cel predmet zkazky
Najniia cena v EUR bez DPH
32 814,00
20%
6 562,80
39 376,80
V Trenne da 12.06. 2013 ______________________________________________
Meno, priezvisko a podpis tatutrneho zstupcu uchdzaa
KPA MODULRNEHO MERACIEHO SYSTMU NA BZE PXIe/PXI
projekt: Zvyovanie energetickej bezpenosti SR, ITMS: 26220220077
ELVAC SK s.r.o.; Zlatovsk 27, 911 01 Trenn, Slovensk republika
Popis produkt: 1) 778636-01 NI PXI-1042 8-Slot 3U Chassis NI PXI-1042 je sk prmyslovho potae obsahujc 8 slot pro moduly uren k men, zen, i testovn. Skn NI PXI spluj bn PXI standard a obsahuj tak linky pro pokroilou synchronizaci, triggerovn a asovn. Na zkladn desce tto skn je generovn hodinov signl s frekvenc 10 MHz, kter me bt pouit pro synchronizaci pouitch modul. Sk PXI-1042 je napjena ze st pomoc vestavnho AC zdroje. Maximln propustnost PXI systmu je 132MB/s. 2) 763067-01 Power Cord, 240V, 10A, Euro, Right Angle Standardn napjec kabel pro sk PXI-1042. 3) 781860-04 NI PXI-8115 Core i5-2510E 2.5 GHz NI PXI-8115 je zsuvn modul slouc jako kontrolr pro PXI sk. Kontrolr a sk spolu tvo prmyslov pota splujc standardy PXI. PXI-8115 je pedinstalovn operanm systmem Windows 7 (32- bit) umoujcm jednoduch programovn pmo na kontrolru. NI PXI-8115 obsahuje vkonn procesor Intel Core i5-2510E s taktovac frekvenc 2.5 GHz. Tento kontrolr umouje krtkodob petaktovn jednoho jdra a na 3.1 GHz, a tedy dosaen vt rychlosti nap. pi zpracovn signlu. Kontrolr je tak vybaven 2GB operan pamt DDR3 1333 MHz. Na elnm panelu NI PXI-8115 jsou umstny porty pro komunikaci pes Ethernet, USB, ExpressCard/34, GPIB, sriovou linku a dal. 4) 778270-01NI PXI-5422 AWG NI PXI-5422 je zsuvn modul fungujc jako genertor uivatelem definovanch prbh, splujc standard PXI. Tento genertor je schopn generovat vzorky s frekvenc a 200MS/s s 16-ti bitovm rozlienm. Genertor obsahuje 256MB zabudovan pamti, co umouje rychl generovn velmi dlouhch prbh bez nutnosti poslat vzorky z kontrolru a vytovat tak processor v prbhu generovn. Genertor me bt synchronizovn prostednictvm PXI linek s ostatnmi PXI moduly, nap. dalmi genertory a vytvoit tak vcekanlov systm. 5) 781860-04 NI PXI-4072 6 1/2 Digit FlexDMM & LCR NI PXI-4072 je zsuvn PXI modul, kter spojuje funkcionalitu t zazen 6 slicov digitln multimetr, LCR metr a 1.8 MS/s digitizer (osciloskop). Tento modul roziuje monosti bnho multimetru o funkcionality bn pi komplexnm men i testovn, jako je men napt, proudu, inductance, teploty, odporu, atd..Integrovn tchto men do jednoho modulu zvyuje propustnost systmu a et msto v PXI skni pro dal moduly. 6) 778270-01 NI PXI-4071 7 1/2 Digit FlexDMM NI PXI-4071 je 7 mstn digitln multimetr pro platformu PXI umoujc mit napt v rozsahu +-1000V s citlivost 10 nV, proud v rozsahu +-3A s citlivost 1pA a odpor v rozsahu 10 uOhm 5 GOhm. Maximln rychlost men je 1.8 MS/s. Multimetr je jednodue pouiteln s pepnai NI PXI pro testovn a men vtho mnostv kanl. 7) 779630-01 NI PXI-6229, M Series DAQ Jedn se o multifunkn PXI modul obsahujc 32 analogovch vstup se sdlenm AD pevodnkem, 48 digitlnmi vstupy/vstupy, tymi analogovmi vstupy a vestavnmi tai. Analogov vstup m maximln agregovanou vzorkovac frekvenci 250 kS/s. Maximln mic vstupn rozsah je +- 10V a minimln +- 200mV. Karta je vhodn pro men s vtm potem kanl, i zen pomoc digitlnch linek. Karta je dodvna s driverem NI-DAQmx, kter lze programovat z prosted NI LabVIEW, NI Signal Express, i jinch vvojovch prosted umoujcch volat sdlen knihovny (DLL). Detailn popis v anglickm jazyce lze nalzt na konkrtn produktov strnce na webu www.ni.com.
OverviewThe National Instruments PXI-4072 FlexDMM, based on the
NI 4070 architecture, combines the functionality found in three
common test instruments digital multimeter, LCR meter, and
digitizer. This functionality provides engineers with the 20 most
common test functions in a compact 3U PXI module, including
voltage, current, capacitance, inductance, temperature, and
resistance. Integrating these measurements in a PXI module reduces
test system size and cost, increases throughput, and shortens test
development time, making it an excellent fit for use in automated
tests on both the production floor and in an R&D environment.
High-Speed Digital Multimeter
1.8 MS/s Flexible-Resolution Isolated Digitizer Users can vary the resolution of the PXI-4072 from 10 to 23 bits
by simply changing the sampling rate, as reflected in Figure 1.
Analyze transients, fly-back signals, or other a periodic high-
voltage AC waveforms in both the time and frequency domain.
Precision Inductance and Capacitance Measurements Delivers 0.15% + 0.1% basic accuracy for both inductance and
capacitance at measurement rates up to 40 S/s
Ideal for component screening, cable capacitance testing, wafer
level go/no-go, and automotive sensors
Built-In Self-Calibration and 2-Year Calibration Cycle Self-calibration (Self-Cal) improves accuracy by removing errors
due to temperature variation and long-term drift.
Self-cal ensures accuracy over entire 0 55 C operating range
2-year external calibration cycle reduces downtime and
maintenance costs
Software Ships with NI-DMM driver software which is an IVI-compliant
driver that provides access to the complete functionality of the DMM
through an easy-to-use application programming interface.
Includes the DMM Soft Front Panel for interactive control
612-Digit Digital Multimeter, 1.8 MS/s Isolated Digitizer, and LCR Meter
Table 1. NI 4072 FlexDMM
Max Sampling Rate1
Digits Resolution (bits) (DC Voltage and Current) Reading Rate2
7 23 5 S/s 5 S/s6 12 22 100 S/s 100 S/s5 12 18 5 kS/s 3 kS/s4 12 15 20 kS/s 10 kS/s3 10 1.8 MS/s 1Maximum sample rate refers to waveform acquisition 2Autozero disabled, except 7 digits, measured on a 10 V and 10 k range
71/2
7
R d i /
Digits
61/2
6
51/2
5
41/2
4
31/2
1 1 0 100 1 k 10 k 100 k 1 M 10 M
Reading Rate (DMM) Sampling Rate (Digitizer)
Figure 1. NI 4072 FlexDMMs Resolution Versus Sampling Rate
NI PXI-4072 FlexDMM Superior accuracy and
measurement rates Multifunction device
612-digit digital multimeter 1.8 MS/s isolated digitizer LCR meter (inductance,
capacitance, and resistance) 20 built-in measurements 10 to 23-bit flexible resolution Built-in self-calibration 300 VDC/Vrms isolation 420 Vp AC measurements
Calibration Gain, temperature, and
offset self-calibration 2-year external calibration cycle
Operating Systems Windows 2000/NT/XP
Recommended Software LabVIEW LabVIEW Real-Time LabWindows/CVI Measurement Studio
Driver Software (included) NI-DMM DMM Soft Front Panel
612-Digit Digital Multimeter, 1.8 MS/s Isolated Digitizer, and LCR Meter
2 National Instruments Tel: (800) 433-3488 Fax: (512) 683-9300 [email protected] ni.com
NI PXI-4072 ..................................................................778270-01Includes the probe set, NI-DMM, DMM Soft Front Panel, and calibration certificate.
Recommended Switching and AccessoriesPXI-2503 24x1 multiplexer switch ..............................777697-01PXI-2530 128x1 multiplexer switch ............................778660-01
Standard probe, P-1 probe set ......................................761000-01Additional probe, P-2 probe set ..................................184698-01Banana plug to bare wire, P-3 probe set ......................185692-0110 A current shunt, CSM-10A ....................................777488-02
Ordering Information
Typical for 0 to 55 C unless otherwise noted.Specifications subject to change without notice. For the most current specifications, visit ni.com/instruments
DC Functions
DC Voltage Maximum Reading Rate
DC System SpeedsRange or function changes .............................. 100 changes/sAutorange time, VDC and ADC........................ 5 msAutorange time, resistance.............................. 50 msTrigger latency.................................................. 2 sMaximum trigger rate ...................................... 6 kHz
DC Accuracy Specifications
DC Voltage (ppm1 of reading + ppm of range)
Specifications
DC Current1 (ppm of reading + ppm of range)
Resistance (4-Wire and 2-Wire1) (ppm of reading + ppm of range)
Diode Test1
Additional Noise Errors for DC Voltage, Current, Resistance
DC Functions GeneralEffective Common-Mode Rejection Ratio (CMRR) (1 k resistance in LO lead) ............................ >170 dB (DC, >46 Hz), with high-order DC noise rejection,
100 ms apertureMaximum 4-wire lead resistance .................... Use the lesser of 10% of range or 1 kOverrange ......................................................... 105% of range except 300 V and 1 A rangeDC voltage input bias current .......................... 10 G,10 M 10 + 10 30 + 20 40 + 20 4 + 5 0.3 + 0.3
1 V 1 V > 10 G,10 M 6 + 2 20 + 6 25 + 6 2 + 1 0.3 + 0.310 V 10 V > 10 G,10 M 4 + 2 20 + 6 25 + 6 1 + 1 0.3 + 0.3
100 V 100 V 10 M 6 + 2 30 + 6 35 + 6 4 + 1 0.3 + 0.3300 V 1 mV 10 M 6 + 6 30 + 20 35 + 20 4 + 3 0.3 + 0.3
1 1 ppm (part per million) = 0.0001% 2 Relative to external calibration source 3 Using internal self-calibration; specificationsvalid over the entire operating temperature range 4 With offset nulling and 100 ms aperture Tcal = temperature at which lastself-calibration or external calibration was performed Tempco = temperature coefficient
Burden Voltage 2 Year Tempco/CRange Resolution (Typical) Noise2 (0 - 55 C) (0-55 C)20 mA 10 nA < 20 mV 20 400 + 75 8 +1200 mA 100 nA < 200 mV 3 400 + 20 8 + 0.21 A 1 A < 800 mV 3 500 + 20 8 + 0.41Typical 24 hour accuracy (23 C 1 C) is (50 ppm of reading + 5 ppm of range) 2In ppm of range rms
Tempco = temperature coefficient
Tempco/C (0-55 C)Test Max Test 24 Hr3 90 Day4 2 Year4 Without With
Range Resolution Current2 Voltage Tcal 1 C Tcal 5 C Tcal 5 C Self-Cal Self-Cal100 5 100 1 mA 100 mV 15 + 10 50 + 10 80 + 10 8 + 1 0.8 + 1
1 k 1 m 1 mA 1 V 12 + 2 50 + 3 80 + 3 8 + 0.1 0.8 + 0.110 k 10 m 100 A 1 V 12 + 2 50 + 3 80 + 3 8 + 0.1 0.8 + 0.1100 k 100 m 10 A 1 V 15 + 2 50 + 6 80 + 6 8 + 0.5 0.8 + 0.5
1 M 1 10 A 10 V 20 + 2 60 + 10 90 + 10 8 + 1 0.8 + 110 M 10 1 A 10 V 100 + 2 200 + 10 400 + 10 30 + 3 30 + 3100 M 6 100 1A || 10 M 10 V 900 + 20 1,800 + 40 2,000 + 40 200 + 10 200 + 101Perform offset nulling or add 200 m to reading 2-10% to 0% tolerance 3Relative to external calibration source 4Usinginternal self-calibration; specifications valid over the entire operating temperature range 5With offset compensated ohms enabled6 2-wire ohms measurement only. Typical accuracy is 5% between 105 M and 1.05 G. Use tempco outside 18 C to 28 CTcal = temperature at which last self-calibration or external calibration was performed Tempco = temperature coefficient
Range Resolution Test Current2 Accuracy10 V 10 V 1 A, 10 A, 100 A, 1 mA3 Add 20 ppm of reading to 10 V
DC voltage specifications1 Can be used to test p-n junctions, LEDs, or zener diodes up to 10 V 2 -10% to 0% tolerance 3 Up to 4.5 V measurement for1 mA test current
Resolution Additional Noise Error512 digits 10 ppm of range5 digits 30 ppm of range412 digits 100 ppm of range
Readings/s NMRR Conditions10 >100 dB1 All noise sources >46 Hz50 (60) >60 dB2 50 (60) Hz 0.1%1 With high-order DC noise rejection, 100 ms aperture2 With normal DC noise rejection; 20 ms (16.67 ms) aperture
Digits Reading Rate Bandwidth612 0.25 S/s 1 Hz to 300 kHz612 2.5 S/s 10 Hz to 300 kHz612 25 S/s 100 Hz to 300 kHz612 100 S/s 400 Hz to 300 kHz512 1 kS/s 20 kHz to 300 kHz
71/2
7
R d i /
Digits
61/2
6
51/2
5
41/2
4
31/2
1 1 0 100 1 k 10 k 100 k 1 M 10 M
Reading Rate (DMM) Sampling Rate (Digitizer)
612-Digit Digital Multimeter, 1.8 MS/s Isolated Digitizer, and LCR Meter
3National Instruments Tel: (800) 433-3488 Fax: (512) 683-9300 [email protected] ni.com
AC Accuracy Specifications
AC Voltage1 2 Year (% of reading + % of range), 23 C 10 C
AC Current1 2 Year (% of reading + % of range), 0-55 C
No degradation in accuracy due to crest factor for signals up to the rated peak voltage/current orbandwidth occurs. For high crest factor signals, increase range. For example, for a 500 mVrms signal with a crest factor between 2 and 10, use the 5 V range.
AC Functions GeneralInput impedance............................................... 1 M in parallel with 150 pFInput coupling................................................... AC or DC couplingMaximum volt-hertz product............................ >8 x 107 V-HzMaximum DC voltage component.................... 250
CMRR(1 k resistance in LO lead) ............................ >70 dB (DC to 60 Hz)Overrange ......................................................... 105% of range except 300 V, 1 A range
Frequency and Period1
Capacitance and InductanceCapacitance and Inductance System SpeedsRange or function change ................................ 10/s
Capacitance Accuracy Specifications
Capacitance (% of reading + % of range), 23 C 10 C
Inductance Accuracy Specifications
Inductance (% of reading + % of range), 23 C 10 C
Capacitance and Inductance General Specifications
Capacitance underrange .................................. 5% of rangeInductance overrange....................................... 110% of rangeLead compensation .......................................... OPEN/SHORTExcitation technique1 ....................................... Multi-tone, constant currentMeasurement technique1................................. Measures fundamental and third harmonic of voltage
waveform, and calculates inductance or capacitance using FFT peak analysis
Measurement configuration ............................ 2-wire with lead compensationDC bias (capacitance only)............................... 0.46 V from H1 to 2.0, user selectable (off by default)
1Patents pending
Isolated DigitizerAcquisition SystemSampling rate and record duration
Available sample rates.............................. r =
where y=1, 2, 3,1.8 x 105
Minimum record duration.......................... 8.89 sMaximum record duration......................... 149 sRecord duration ......................................... n/r, where n = number of samples, r = sampling rate
Variable resolution ........................................... 10 to 23 bits; refer to the Digitizer Maximum SamplingRate graph
Available functions........................................... Voltage and currentVoltage ranges ................................................. 100 mV to 300 V
(DC or AC coupled)Current ranges.................................................. 20 mA to 1 ATimebase accuracy ........................................... 25 ppmInput Trigger
Latency....................................................... 1.8 sJitter .......................................................... 200 A. Tempco = temperature coefficient
2 Year Accuracy 2
Input Range Frequency Range Period Range Resolution 0 - 55 C % of reading50 mV to 300 V 1 Hz to 500 kHz 1 s to 2 s 612 digits 0.0112 second gate time; input signal must be >10% of AC voltage input range 20.0025% of reading typical
1.8 MS/sy
,
Range Peak 1 Hz to 40 Hz to 20 kHz to 50 kHz to 100 kHz to(rms) Voltage Resolution 40 Hz2 20 kHz 50 kHz 100 kHz 300 kHz50 mV3 105 mV 100 nV 0.1 + 0.04 0.05 + 0.04 0.09 + 0.04 0.5 + 0.08 3 + 0.1500 mV 1.05 V 1 V
5 V 10.5 V 10 V 0.1 + 0.01 0.05 + 0.02 0.09 + 0.02 0.5 + 0.02 3 + 0.0550 V 105 V 100 V300 V 450 V 1 mVTempco/C (0C-50 C) 0.001 + 0.001 0.001 + 0.001 0.001 + 0.001 0.001 + 0.001 0.01 + 0.011After self-calibration. Measurement aperture greater than 4/fL, where fL is the lowest frequency component of the signalbeing measured 2 Specification applies for DC coupling. 3 Applies to signals >2 mV. Tempco = temperature coefficient
Mode Ranges Reading RateCapacitance 300 pF, 1 nF, 10 nF, 100 nF, 1 F, 10 F 20 S/s
100 F, 1000 F, 10,000 F 3 S/sInductance 10 H, 100 H 40 S/s
1 mH, 10 mH 20 S/s100 mH, 1 H, 5 H 3 S/s
24
Samples/s
Bits
810 100 1 k 10 k 100 k 1 M 10 M
10
12
14
16
18
20
22
Flatness THD2 THD2
Input 2 Year Error 2 Bandwidth 2,3 1 kHz Signal, 20 kHz Signal, Tempco/C Range Impedance1 Tcal 5 C 20 kHz (-3 dB) -1 dBfs -1 dBfs (0 - 55 C)100 mV 4 >10 G,1 M 45 + 30 -0.03 dB 300 kHz -104 dB -78 dB 4 + 6
1 V >10 G,1 M 35 + 6 -0.03 dB 300 kHz -109 dB -83 dB 3 + 110 V >10 G,1 M 30 + 6 -0.03 dB 300 kHz -96 dB -70 dB 3 + 1
100 V 1 M 45 + 6 -0.03 dB 300 kHz -96 dB -70 dB 7 + 1300 V 1 M 45 + 30 -0.03 dB 300 kHz -98 dB -72 dB 7 + 31 Parallel with 150 pF. 2 Typical specification. 3 The AC coupling low frequency (-3 dB) point is 0.8 Hz. 4 With offset nulling.Tcal = temperature at which last self-calibration or external calibration was performed. Tempco = temperature coefficient.
Tempco/C Effective Effective DefaultRange Resolution 2 Year1 (0-55 C) Test Current2 Frequency2 Model300 pF 0.05 pF 0.15 + 0.5 0.01 + 0.025 160 nA 3 kHz Parallel1 nF 0.1 pF 0.15 + 0.5 0.01 + 0.003 330 nA 3 kHz Parallel10 nF 1 pF 0.15 + 0.5 0.01 + 0.001 330 nA 3 kHz Parallel100 nF 10 pF 0.15 + 0.5 0.01 + 0.001 3.3 A 3 kHz Parallel1 F 100 pF 0.18 + 0.1 0.01 + 0.001 100 A 1 kHz Series10 F 1 nF 0.18 + 0.1 0.01 + 0.001 1 mA 1 kHz Series100 F 10 nF 0.18 + 0.1 0.01 + 0.001 1 mA 91 Hz Series1,000 F 100 nF 0.18 + 0.1 0.01 + 0.001 1 mA 91 Hz Series10,000 F 1 F 0.18 + 0.1 0.01 + 0.001 1 mA 91 Hz Series
1Relative to external calibration source. After lead compensation with >3 meters of coaxial or shielded twisted-pair cabling.Specifications apply to >5% of range and
612-Digit Digital Multimeter, 1.8 MS/s Isolated Digitizer, and LCR Meter
4 National Instruments Tel: (800) 433-3488 Fax: (512) 683-9300 [email protected] ni.com
Current (ppm of reading + ppm of range)
GeneralSelf-calibration................................................. Calibrates the FlexDMM relative to high-precision internal
voltage and resistance standards. No external calibrationequipment required.
External calibration interval ............................. 2 year recommendedInput protection
Resistance, diode ...................................... Up to 300 V DCDC V, AC V ................................................. Up to 300 V DC, 300 V ACrms,450 V AC peakDC I and AC I ............................................. 1.25 A, 250 V fast-acting user replaceable fuse
Maximum common-mode voltage ................... 300 VInput terminals ................................................. Gold-plated low-thermal EMF solid copperTriggers
Measurement completetrigger pulse width .................................... 3 sInput trigger pulse width........................... 1 s, with
NI Services and SupportNI has the services and support to meet your
needs around the globe and through the
application life cycle from planning
and development through deployment
and ongoing maintenance. We offer
services and service levels to meet
customer requirements in research,
design, validation, and manufacturing.
Visit ni.com/services.
Training and CertificationNI training is the fastest, most certain route to productivity with our
products. NI training can shorten your learning curve, save
development time, and reduce maintenance costs over the
application life cycle. We schedule instructor-led courses in cities
worldwide, or we can hold a course at your facility. We also offer a
professional certification program that identifies individuals who
have high levels of skill and knowledge on using NI products.
Visit ni.com/training.
Professional ServicesOur Professional Services Team is comprised of NI applications
engineers, NI Consulting Services, and a worldwide NI Alliance
Partner Program of more than 600 independent consultants and
integrators. Services range
from start-up assistance to
turnkey system integration.
Visit ni.com/alliance.
OEM SupportWe offer design-in consulting and product integration assistance
if you want to use our products for OEM applications. For
information about special pricing and services for OEM customers,
visit ni.com/oem.
Local Sales and Technical SupportIn offices worldwide, our staff is local to the country, giving you
access to engineers who speak your language. NI delivers industry-
leading technical support through online knowledge bases, our
applications engineers, and access to 14,000 measurement and
automation professionals within NI Developer Exchange forums.
Find immediate answers to your questions at ni.com/support.
We also offer service programs that provide automatic upgrades to
your application development environment and higher levels of
technical support. Visit ni.com/ssp.
Hardware ServicesNI Factory Installation ServicesNI Factory Installation Services (FIS) is the fastest and easiest way to
use your PXI or PXI/SCXI combination systems right out of the
box. Trained NI technicians install the software and hardware and
configure the system to your specifications. NI extends the standard
warranty by one year on hardware components (controllers, chassis,
modules) purchased with FIS. To use FIS, simply configure your
system online with ni.com/pxiadvisor.
Calibration Services NI recognizes the need to maintain properly calibrated devices for
high-accuracy measurements. We provide manual calibration
procedures, services to recalibrate your products, and automated
calibration software specifically designed for use by metrology
laboratories. Visit ni.com/calibration.
Repair and Extended Warranty NI provides complete repair services for our products. Express repair
and advance replacement services are also available. We offer
extended warranties to help you meet project life-cycle requirements.
Visit ni.com/services.
SERVICE NEEDS
2004 National Instruments Corporation. All rights reserved. LabVIEW, CVI, Measurement Studio, and ni.com are trademarks of National Instruments. Product and company names listed are trademarks or trade names of their respective companies.
National Instruments Tel: (512) 683-0100 Fax: (512) 683-9300 [email protected]
ni.com (800) 433-3488
712-Digit, 26-Bit, 1000 V Digital Multimeter and 1.8 MS/s Isolated Digitizer
OverviewThe NI PXI-4071 712-digit FlexDMM is a high-performance, multifunction
3U PXI module that provides the measurement capability found in two
common test instruments a high-resolution digital multimeter (DMM)
and a digitizer. As a DMM, the PXI-4071 delivers fast, accurate voltage
measurements from 10 nV to 1000 V, current measurements from 1 pA
to 3 A, and resistance measurements from 10 to 5 G, as well astakes frequency/period and diode measurements. In the high-voltage,
isolated digitizer mode, the PXI-4071 can acquire DC-coupled waveforms
at sample rates up to 1.8 MS/s in all voltage and current modes. Using
the analysis functions in NI LabVIEW software, you can analyze these
waveforms in both the time and frequency domains. The PXI-4071 offers
superior speed, accuracy, and functionality, making it an excellent fit
for use in automated tests on both the production floor and in an
R&D environment.
High-Speed Digital MultimeterThe PXI-4071 surpasses conventional 712-digit DMM speed/performance
barriers by using a modern architecture that exploits the high-speed PXI
bus. At 712 digits, the PXI-4071 achieves DC reading rates of 7 S/s. For
applications requiring higher throughput, it has a maximum DC reading
rate of 10 kS/s at 412 digits, as depicted in Table 1. These rates are at
least five times faster than the traditional GPIB-controlled DMMs.
Wide Dynamic Range of MeasurementsThis FlexDMM can measure 1000 VDC and 700 Vrms at CAT I levels.
In addition, the PXI-4071 uses a novel solid-state current shunt
configuration, which delivers current sensitivity down to 1 pA, as
shown in Table 2.
This wide measurement range makes it ideal for applications
such as fuel cell testing, leakage measurements, current-voltage curve
tracing analysis, off-state semiconductor device measurements, and
battery testing.
Superior accuracy and measurement rates
10- to 26-bit flexible resolution Wide dynamic range of measurements 10 nV to 1000 VDC
(700 VAC) voltage 1 pA to 3 A current 10 to 5 G resistance 500 VDC/Vrms
common-mode isolation 1.8 MS/s isolated waveform acquisition Up to 1000 V and 3 A input
Calibration Gain and offset self-calibration 2-year external calibration cycle
Operating System Windows Vista/XP/2000 Linux
Recommended Software LabVIEW LabVIEW Real-Time Module LabWindows/CVI Measurement Studio LabVIEW SignalExpress
Software (included) NI-DMM driver LabVIEW Express VIs DMM Soft Front Panel
NI PXI-4071
Digits BitsMaximum Sampling
Rate (Digitizer)Reading Rate
(DMM)
712 26 7 S/s612 22 100 S/s 100 S/s512 18 5 kS/s 3 kS/s412 15 20 kS/s 10 kS/s3 10 1.8 MS/s
Table 1. PXI-4071 Sampling Rate
Fast, Accurate AC MeasurementsWith NI FlexDMM devices, slow AC measurements are a thing of
the past. FlexDMM devices achieve unprecedented AC measurement
speeds by solving a traditional analog problem, rms-to-DC conversion,
in the digital domain. They use a digital algorithm that requires only a
few cycles of a waveform to compute rms values, which dramatically
increases AC reading rates. The digital algorithm automatically rejects
the DC component of the signal, making it possible to bypass the slow-
settling input capacitor. To measure small AC voltages in the presence
of large DC offsets, such as ripple on a DC power supply, FlexDMM devices
offer the standard AC volts mode, which uses a coupling capacitor to
eliminate the offset so the FlexDMM can use the most sensitive range.
The digital approach to rms computation offers accuracy benefits as
well. The algorithm is completely insensitive to crest factor, and can
deliver exceptionally quiet and stable readings. The PXI-4071 guarantees
AC accuracy down to 1 percent of full scale, rather than the 10 percent
of full scale offered by traditional DMMs; it can achieve usable readings
even below 0.1 percent of full scale.
1.8 MS/s Flexible-Resolution Isolated DigitizerThe architectural design of the PXI-4071 incorporates a 1.8 MS/s
isolated digitizer. In the isolated digitizer mode, the PXI-4071 can acquire
DC-coupled waveforms in all voltage and current ranges, at a maximum
sampling rate of 1.8 MS/s. With isolation, you can measure differential
waveforms with high levels of common-mode voltage. By using LabVIEW
software with the isolated digitizer capability of FlexDMM devices, you
can analyze transients, fly-back signals, or other aperiodic high-voltage
AC waveforms in both the time and frequency domains. No other
712-digit DMM has this capability.
You can vary the resolution of the PXI-4071 from 10 to 23 bits
by simply changing the sampling rate, as reflected in Figure 1.
This unique multi-instrument functionality minimizes overall system costs
by eliminating the need to purchase a separate data acquisition device,
signal conditioning, and fixturing. The FlexDMM is entirely software
programmable and requires no external hardware intervention.
Built-In Self-Calibration and Two-Year Calibration CycleThe NI FlexDMM offers self-calibration, which is traditionally found in
only the highest-resolution DMMs costing thousands of dollars more.
Self-calibration corrects for all DC gain and offset drifts within the DMM
using a precision, high-stability internal voltage reference that has an
outstanding temperature coefficient and time drift. Self-calibration also
accounts for all resistance and current source drifts. In resistance, all
errors are corrected to a single internal high-stability foil resistor, stable
to within 0.8 ppm/C over the full operating range.
Self-calibration makes the FlexDMM highly accurate and very
stable at any operating temperature well outside of the traditional
18 to 28 C range. Self-calibration takes less than a minute to complete
and requires no external calibrator. With the self-calibration precision
circuitry, NI can offer a two-year external calibration cycle on the PXI-4071.
Tight Switch IntegrationThe PXI-4071 can import and export triggers, making it easy to integrate
them with any multiplexer/matrix switch modules. In particular, the
FlexDMM integrates seamlessly with National Instruments switch
offerings, such as the NI PXI-2530 multiplexer and the NI SCXI-1129
high-density matrix. When you use a PXI-4071 with these NI switch
modules and NI Switch Executive switch management software, you can
measure thousands of channels, consisting of voltages, thermocouples,
RTDs, and thermistors. You can also keep a firm control on the cost of
your system. For more details on NI switching, visit ni.com/switches.
712-Digit, 26-Bit, 1000 V Digital Multimeter and 1.8 MS/s Isolated Digitizer
2
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)
10 100 1 k 10 k 100 k 1 M 10 M8
10
12
14
16
18
20
24
22
Samples/s
Bits
Figure 1. PXI-4071 Frequency versus Resolution Flexibility
PXI-4071 PXI-4070Voltage Ranges (V)Maximum DC 1000 300DC sensitivity 10 n 100 nMaximum ACrms (peak) 700 rms (1000) 300 rms (425)Common mode 500 300Current Ranges (A)Maximum DC 3 1DC sensitivity 1 p 10 nMaximum ACrms (peak) 3 (4.2) 1 (2)ACrms sensitivity 100 p 10 nResistance Ranges ()Maximum 5 G 100 MSensitivity 10 100
Table 2. FlexDMM Input Range Comparison
CalibrationEach PXI-4071 is calibrated to NIST-traceable standards to the
levels detailed in the specifications. You can find the calibration
certificate at ni.com/calibration. You can return the FlexDMM devicesto National Instruments or to a qualified metrology lab for calibration.
SoftwareAll National Instruments DMMs are shipped with NI-DMM driver
software. NI-DMM is an IVI-compliant driver that provides numerous
example programs and access to the complete functionality of the DMM
through an easy-to-use application programming interface (API).
NI-DMM 2.4 or later contains the DMM Express VI, with which you
can quickly develop a FlexDMM application in LabVIEW or LabVIEW
SignalExpress through interactive configuration dialogs and can preview
measurement results immediately.
NI-DMM also includes the DMM Soft Front Panel (SFP). The DMM
SFP is an interactive executable that provides an easy way to test input
signals or debug your system. NI-DMM is optimized for use with
LabVIEW, LabWindows/CVI, Measurement Studio, and Microsoft Visual
Studio .NET.
712-Digit, 26-Bit, 1000 V Digital Multimeter and 1.8 MS/s Isolated Digitizer
3
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)
Ordering Information
NI PXI-4071............................................................................778271-01Includes the P-1 probe set, NI-DMM, and DMM Soft Front Panel.
Recommended Switching and AccessoriesNI PXI-2503 24x1 multiplexer switch....................................777697-01
NI PXI-2530 128x1 multiplexer switch..................................778660-01
NI SCXI-1127 250 V multiplexer switch................................776572-27
P-1 probe set (standard probe)..............................................761000-01
P-2 probe set (additional probe)............................................184698-01
P-3 probe set (banana plug to bare wire) ............................185692-01
10 A current shunt, CSM-10A ..............................................777488-02
BUY NOW!For complete product specifications, pricing, and accessory information, call 800 813 3693 (U.S.) or go to ni.com/dmm.
SpecificationsSpecifications are subject to change without notice. For the mostcomplete and current specifications, visit ni.com/modularinstruments.
DC Specifications
DC Voltage Maximum Reading Rate
DC Voltage (ppm1 of reading + ppm of range)
DC System SpeedsRange or function change................... 100/sAutorange time, DC V and DC I .......... 5 msAutorange time, resistance ................ 50 msTrigger latency..................................... 2 sMaximum trigger rate......................... 6 kHz
DC Accuracy SpecificationsNote: All DC voltage accuracy specifications apply to 712-digitresolution with Auto Zero and ADC calibration enabled.
Additional Noise Error
RMS Noise1
Note: All DC current specifications apply to 612-digitresolution with Auto Zero and ADC calibration enabled.
712-Digit, 26-Bit, 1000 V Digital Multimeter and 1.8 MS/s Isolated Digitizer
4
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)
Digits BitsMaximum Sampling
Rate (Digitizer)1Reading Rate
(DMM)2
712 26 7 S/s612 22 100 S/s 100 S/s512 18 5 kS/s 3 kS/s412 15 20 kS/s 10 kS/s3 10 1.8 MS/s 1Maximum sampling rates refer to waveform acquisition in digitizer mode.2Auto Zero disabled, except 712 digits; measured on a 10 V and 10 k range.
1 10010 1 k 10 k 100 k 1 M 10 M3
31/2
4
41/2
5
51/2
6
7
71/2
61/2
Reading/s
DMM (Reading Rate) Digitizer (Sample Rate)
Digi
ts
0.01 10.1 10 1000.01
1
10
0.1
Integration Time (NPLC)
RMS
Noi
se(p
pmof
rang
e)
Tempco/C 0 to 55 C90-Day3
18 to 28 C Tcal 1 C
2-Year3
18 to 28 C Tcal 1 C
2-Year3
0 to 55 C Tcal 5 C
Input Resistance
24-Hour2
Tcal 1 CWithout Self-Cal
With Self-CalRange Resolution
100 mV4 10 nV >10 G, 5 + 4 18 + 7 20 + 8 3 + 2 0.3 + 1 30 + 1010 M
1 V5 100 nV >10 G, 4 + 0.8 13 + 0.8 15 + 0.8 2 + 0.2 0.3 + 0.1 22 + 0.810 M
10 V 1 V >10 G, 2 + 0.5 9 + 0.5 12 + 0.5 0.3 + 0.02 0.3 + 0.01 15 + 0.510 M
100 V 10 V 10 M 5 + 2 18 + 2 20 + 2 4 + 0.2 0.3 + 0.1 32 + 21000 V6 100 V 10 M 4 + 0.5 18 + 0.5 20 + 0.5 3 + 0.02 0.3 + 0.01 32 + 0.511 ppm (part per million) = 0.0001%. 2Relative to external calibration source. 3Using internal self-calibration; specifications valid over the entire operating temperature range. 4With offset nulling and 100 ms aperture. 5With offset nulling; add 1.3 ppm of range for no offset nulling. 6For inputs above 300 V, add 25 ppm x (VIN/1000 V) ^2 to the 90-Day and 2-Year columns. Tcal = temperature at which last self-calibration or external calibration was performed. Tempco = temperature coefficient.
Range Multiplier100 mV X 151 V X 210 V X 1100 V X 61000 V X 11Multiply the RMS noise value from the graph above by the range-appropriate multiplier in this table. For the peak-to-peak noise error,multiply the RMS noise by 6.
DC Current (ppm of reading + ppm of range)
Additional Noise Errors for Current
Note: All resistance specifications apply to 712-digitresolution with Auto Zero and ADC calibration enabled.
Resistance (4- and 2-wire1) (ppm of reading + ppm of range)
712-Digit, 26-Bit, 1000 V Digital Multimeter and 1.8 MS/s Isolated Digitizer
5
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)
Resolution Additional Noise Error512 digits 10 ppm of range5 digits 30 ppm of range412 digits 100 ppm of range
0.01 10.1 10 1000.1
10
1
Integration Time (NPLC)
RMS
Noi
se(p
pmof
rang
e)
Tempco/C 0 to 55 CMax
Test Voltage
90-Day4
18 to 28 C Tcal 1 C
2-Year4
18 to 28 C Tcal 1 C
2-Year4
0 to 55 CTcal 5 C
TestCurrent2
24-Hour3
Tcal 1 CWithout Self-Cal
With Self-CalRange Resolution
100 5 10 1 mA 100 mV 8 + 2.5 31 + 4 56 + 4 6 + 0.12 0.8 + 0.12 60 + 51 k5 100 1 mA 1 V 5 + 0.5 26 + 0.5 48 + 0.5 5 + 0.05 0.8 + 0.05 55 + 110 k5 1 m 100 A 1 V 5 + 0.5 26 + 0.5 48 + 0.5 5 + 0.05 0.8 + 0.05 55 + 1100 k7 10 m 10 A 1 V 5 + 0.5 28 + 0.5 50 + 0.5 5 + 0.05 0.8 + 0.05 56 + 61 M 100 m 10 A 10 V 5 + 0.5 30 + 0.5 52 + 0.5 5 + 0.05 0.8 + 0.05 58 + 110 M 1 1 A 10 V 60 + 5 70 + 10 90 + 10 20 + 1 20 + 1 400 + 1030 M6 10 1 A
|| 10 M10 V 180 + 20 240 + 30 360 + 60 60 + 20 60 + 20
100 M8 10 1 A|| 10 M
10 V 500 + 6 1600 + 10 2000 + 20 250 + 6 250 + 6
5 G8 10 1 A|| 10 M
10 V 1% + 0.2 5% + 0.2 5% + 0.2 2500 + 0.2 2500 + 0.2
1Perform offset nulling. 2-10 to 0% tolerance. 3Relative to external calibration source. 4Using internal self-calibration; specifications valid over the entire operating temperature range. 5With offset compensated ohms enabled. For ADC calibration disabled, add 4 ppm of 100 range and 0.4 ppm of 1 k and 10 k range to the 90-Day and 2-Year columns. 6Applies to 100 M range up to 30 M. 2-wire resistance measurement only. Use tempco outside 18 to 28 C. 7Perform offset nulling or add 1 ppm of range to the 24-Hour column and add 5 ppm of range to 90-Day and 2-Year columns. 82-wire resistance measurement only. Use tempco outside 18 to 28 C. Tcal = temperature at which last self-calibration or external calibration was performed. Tempco = temperature coefficient.
Additional Noise Error
90-Day3
18 to 28 C Tcal 1 C
2-Year18 to 28 C Tcal 1 C
Burden Voltage
24-Hour1
Tcal 1 CTempco/C 0 to 55 CRange Resolution
1 A 1 pA
RMS Noise1
Note: All diode specifications apply to 612-digitresolution with Auto Zero and ADC calibration enabled.
Diode Test1
DC Function General SpecificationsEffective Common-Mode Rejection Ratio (CMRR)(1 k resistance in LO lead)............... >140 dB (DC), 100 ms aperture
>170 dB (>46 Hz) with high-orderDC noise rejection, 100 ms aperture
Maximum 4-wire lead resistance....... Use the lesser of 10% of rangeor 1 k
Overrange............................................ 105% of range except 1000 Vand 3 A range
DC voltage input bias current............. 1 mVrms.
Range Multiplier100 X 81 k X 110 k X 1100 k X 21 M X 3.510 M X 5100 M X 555 G X 25001Multiply the RMS noise value from the graph above by the range-appropriate multiplier in this table. For the peak-to-peak noise error,multiply the RMS noise by 6.
Range Resolution Test Current2 Accuracy10 V 10 V 1 A, 10 A, 100 A, 1 m3 Add 20 ppm of reading to
10 VDC voltage specification1Can be used to test p-n junctions, LEDs, or zener diodes up to 10 V. 2-10 to 0% tolerance. 3Up to 4.0 Vmeasurement for 1 mA test current.
Range Multiplier Conditions10 >100 dB1 All noise sources >46 Hz50 (60) >60 dB2 50 (60) Hz 0.1%1With high-order DC noise rejection; 100 ms aperture. 2With normal DC noise rejection; 20 ms (16.67 ms) aperture.
Digits Reading Rate Bandwidth612 0.25 S/s 1 Hz to 300 kHz612 2.5 S/s 10 Hz to 300 kHz612 25 S/s 100 Hz to 300 kHz612 100 S/s 400 Hz to 300 kHz512 1 kS/s 20 kHz to 300 kHz
Range(rms)
1 Hzto 40 Hz
40 Hzto 20 kHz
20 kHzto 50 kHz
50 kHzto 100 kHz
100 kHzto 300 kHz
50 mV500 mV5 V
0.001 + 0.0002 0.001 + 0.0002 0.001+ 0.001 0.001 + 0.001 0.01 + 0.01
50 V700 V
0.001 + 0.0002 0.003 + 0.0002 0.012 + 0.001 0.045 + 0.001 0.1 + 0.01
Tempco = temperature coefficient.
Range(rms)
PeakCurrent Resolution
Burden Voltage (rms)
1 Hz to 20 kHz2
Tempco/C 0 to 55 C
100 A3 200 A 100 pA 100 mV 0.03 + 0.02 0.002 + 0.00021 mA 2 mA 1 nA 100 mV 0.01 + 0.02 0.001 + 0.000110 mA 20 mA 10 nA 100 mV 0.011 + 0.02 0.002 + 0.0002100 mA 200 mA 100 nA 100 mV 0.02 + 0.02 0.001 + 0.00021 A 2 A 10 A 250 mV 0.04 + 0.02 0.002 + 0.00023 A 4.2 A4 10 A 700 mV 0.1 + 0.02 0.002 + 0.00011Measurement aperture greater than 4/L, where L is the lowest frequency component of the signal being measured. 2Only to 5 kHz for 100 A; specification is typical for the 5 to 20 kHz frequency range.3Applies to signals >9 Arms and
AC Functions General SpecificationsInput impedance ................................. 10 M in parallel with 90 pFInput coupling ..................................... AC or DC couplingMaximum Volt-Hertz product.............. >8 x 107 V-HzMaximum DC voltage component ...... 400 VCMRR
(1 k resistance in LO lead) .......... >70 dB (DC to 60 Hz)Overrange ....................................... 105% of range except 700 V,
3 A range
Frequency and Period1
Isolated Digitizer Specifications
Acquisition SystemSampling rate and record durationAvailable sampling rates .................... r = 1.8 MS/s ,
y
where y = 1, 2, 3,1.8 x 105Minimum record duration ................... 8.89 sMaximum record duration .................. 149 sRecord duration................................... n/r, where n = number of
samples, r = sampling rateVariable resolution.............................. 10 to 23 bits; refer to the
Digitizer Maximum SamplingRate graph
Available functions ............................. Voltage and currentVoltage ranges .................................... 100 mV to 1000 V (DC or
AC coupled)Current ranges .................................... 100 A to 3 ATimebase accuracy.............................. 25 ppmInput trigger
Latency1 .......................................... 3.6 sJitter ............................................... 10% of AC voltage input range. 20.0025% of reading typical.
10 100 1 k 10 k 100 k 1 M 10 M8
10
12
14
16
18
20
24
22
Samples/s
Bits
RangeInput
Impedance1Flatness Error
20 kHzBandwidth2, 3
(-3 dB)THD2 1 kHz
signal, -1 dBFSTHD2 20 kHz
signal, -1 dBFS
100 mV >10 G,10 M
-0.014 dB 340 kHz -108 dB -90 dB
1 V >10 G,10 M
-0.014 dB 336 kHz -110 dB -86 dB
10 V >10 G,10 M
-0.014 dB 345 kHz -90 dB -64 dB
100 V 10 M -0.05 dB 280 kHz -110 dB -92 dB1000 V 10 M -0.05 dB 245 kHz -89 dB -70 dB1In parallel with 90 pF. 2Typical specification. 3The AC coupling low frequency (-3 dB) point is 0.7 Hz.
RangeBurden Voltage
(typical)Flatness Error1
20 kHzBandwidth
(-3 dB)
100 A
General SpecificationsSelf-calibration.................................... Calibrates the FlexDMM
relative to high-precision internal voltage and resistancestandards. Requires no externalcalibration equipment.
External calibration interval................ 2-year recommendedInput protection
Resistance2-wire ......................................... Up to 1000 VDC4-wire ......................................... Up to 500 VDC
Diode............................................... Up to 1000 VDCDC V, AC V ...................................... Up to 1000 VDC, 700 VACrms,
1000 VAC peakDC I and AC I .................................. 3 A, 250 V fast-acting user
replaceable fuseMaximum common-mode voltage ...... 500 VInput terminals .................................... Gold-plated low-thermal EMF
solid copperTriggers
Measurement complete trigger pulse width ......................... 3 sInput trigger pulse width................ 1 s, with
NI Services and Support
NI has the services and support to meet
your needs around the globe and through
the application life cycle from planning
and development through deployment
and ongoing maintenance. We offer
services and service levels to meet
customer requirements in research,
design, validation, and manufacturing.
Visit ni.com/services.
Training and CertificationNI training is the fastest, most certain route to productivity with our
products. NI training can shorten your learning curve, save development
time, and reduce maintenance costs over the application life cycle. We
schedule instructor-led courses in cities worldwide, or we can hold a
course at your facility. We also offer a professional certification program
that identifies individuals who have high levels of skill and knowledge on
using NI products. Visit ni.com/training.
Professional ServicesOur NI Professional Services team is composed of NI applications and
systems engineers and a worldwide National Instruments Alliance
Partner program of more than 600 independent consultants and
integrators. Services range from
start-up assistance to turnkey
system integration.
Visit ni.com/alliance.
OEM SupportWe offer design-in consulting and product integration assistance if you
want to use our products for OEM applications. For information about
special pricing and services for OEM customers, visit ni.com/oem.
Local Sales and Technical SupportIn offices worldwide, our staff is local to the country, giving you access
to engineers who speak your language. NI delivers industry-leading
technical support through online knowledge bases, our applications
engineers, and access to 14,000 measurement and automation
professionals within NI Developer Exchange forums. Find immediate
answers to your questions at ni.com/support.We also offer service programs that provide automatic upgrades to
your application development environment and higher levels of technical
support. Visit ni.com/ssp.
Hardware Services
NI Factory Installation ServicesNI Factory Installation Services (FIS) is the fastest and easiest way to
use your PXI or PXI/SCXI combination systems right out of the box.
Trained NI technicians install the software and hardware and configure
the system to your specifications. NI extends the standard warranty by
one year on hardware components (controllers, chassis, modules)
purchased with FIS. To use FIS, simply configure your system online
with ni.com/pxiadvisor.
Calibration Services NI recognizes the need to maintain properly calibrated devices for
high-accuracy measurements. We provide manual calibration
procedures, services to recalibrate your products, and automated
calibration software specifically designed for use by metrology
laboratories. Visit ni.com/calibration.
Repair and Extended Warranty NI provides complete repair services for our products. Express repair
and advance replacement services are also available. We offer
extended warranties to help you meet project life-cycle requirements.
Visit ni.com/services.
SERVICENEEDS
MAI
NTAIN PLAN
DEVE
LOPDEPLOY
2008 National Instruments. All rights reserved. CVI, FlexDMM, LabVIEW, Measurement Studio, National Instruments, National Instruments Alliance Partner, NI, ni.com, SCXI, andSignalExpress are trademarks of National Instruments. The mark LabWindows is used under a license from Microsoft Corporation. Windows is a registered trademark of MicrosoftCorporation in the United States and other countries. Linux is the registered trademark of Linus Torvalds in the U.S. and other countries. Other product and company names listedare trademarks or trade names of their respective companies. A National Instruments Alliance Partner is a business entity independent from NI and has no agency, partnership, orjoint-venture relationship with NI.
National Instruments [email protected]
ni.com 800 813 3693 *351495D-01*351495D-01 2008-10025-101-D
1/19 www.ni.com
Back to Top
Back to Top
NI M Series low-cost multifunction data acquisition (DAQ) devices provide optimized functionality for cost-sensitive applications. They have up to 80 analog inputs, 48 digital I/O lines, four analogoutputs, two counter/timers, and digital triggering. Low-cost M Series devices have a one-year calibration interval. For better accuracy, faster speeds, and an extended two-year calibration service,consider high-speed and high-accuracy M Series devices.
Requirements and CompatibilityOS InformationLinuxMac OS XWindows 2000/XPWindows 7Windows Vista x64/x86
Driver InformationNI-DAQmxNI-DAQmx Base
Software CompatibilityANSI CLabVIEWLabWindows/CVIMeasurement StudioSignalExpressVisual BasicVisual Studio .NET
Comparison Tables
Family Bus AnalogInputsAnalog Input Resolution
(bits)Analog Outputs
(AO)AO Resolution
(bits)Max AO Rate
(kS/S)AO Range
(V)Digital
I/OCorrelated (clocked)
DIO
NI 6220 PCI, PXI 16 16 - - - - 24 8, up to 1 MHz
NI 6221 PCI, PXI,USB 16 16 2 16 833 10 24 8, up to 1 MHz
NI 6221(37-pin) PCI 16 16 2 16 833 10 10 2, up to 1 MHz
NI 6224 PCI, PXI 32 16 - - - - 48 32, up to 1 MHz
Technical Sales
(866) [email protected]
| | Print E-mail this Page Open Document as PDF
Last Revised: 2011-10-21 10:33:49.0
Low-Cost M Series Multifunction Data Acquisition - 16-Bit, 250 kS/s, up to 80 Analog Inputs
NI recommends high-speed M Series (NI 625x) for 5X faster sampling rates,high-accuracy M Series (NI 628x) for 4X higher resolution, or industrial M Series (NI623x) for 60 VDC isolation and superior noise rejection16, 32, or 80 analog inputs at 16 bits, 250 kS/sUp to 4 analog outputs at 16 bits, 833 kS/s (6 s full-scale settling time)Programmable input range (10, 5, 1, 0.2 V) per channel
Up to 48 TTL/CMOS digital I/O lines (up to 32 hardware-timed at 1 MHz)Two 32-bit, 80 MHz counter/timersDigital triggeringX1, X2, or X4 quadrature encoder inputs
Overview
| | | Requirements and Compatibility Ordering Information Detailed Specifications Pinouts/Front Panel ConnectionsFor user manuals and dimensional drawings, visit the product page resources tab on ni.com.
2/19 www.ni.com
Back to Top
Family Bus AnalogInputsAnalog Input Resolution
(bits)Analog Outputs
(AO)AO Resolution
(bits)Max AO Rate
(kS/S)AO Range
(V)Digital
I/OCorrelated (clocked)
DIO
NI 6225 PCI, PXI,USB 80 16 2 16 833 10 24 8, up to 1 MHz
NI 6229 PCI, PXI,USB 32 16 4 16 833 10 48 32, up to 1 MHz
Application and Technology
M Series for TestFor test, you can use 16-bit, 250 kS/s analog inputs and 1 MHz digital lines with NI signal conditioning for applications including data logging and sensor measurements. Low-cost M Series devicesare compatible with the NI SCC and SCXI signal conditioning platforms, which provide amplification, filtering, and power for virtually every type of sensor. These platforms also are compliant withIEEE 1451.4 smart transducer electronic data sheet (TEDS) sensors, which provide digital storage for sensor data sheet information.
M Series for ControlLow-cost M Series digital lines can drive 24 mA for relay and actuator control. With up to four analog outputs, two 80 MHz counter/timers, and six DMA channels, M Series devices can executemultiple control loops simultaneously. Low-cost M Series devices also have direct support for encoder measurements, protected digital lines, and digital debounce filters for control applications. Withup to 80 analog inputs, 32 clocked digital lines at rates of 1 MHz, and four analog outputs, you can execute multiple control loops with a single device. For higher-count control loops, you can use MSeries devices in conjunction and tightly synchronized with National Instruments analog output devices for 64 or more loops.
M Series for DesignYou can use the wide range of I/O from 80 analog inputs to 48 digital lines to measure and verify prototype designs. M Series devices and NI LabVIEW SignalExpress interactive measurementsoftware deliver benchtop measurements to the PC. With LabVIEW SignalExpress interactive configuration-based steps, you can quickly create design verification tests. The fast acquisition andgeneration rates of low-cost M Series devices along with LabVIEW SignalExpress provide on-the-fly design analysis. You can convert your tested and verified LabVIEW SignalExpress projects toLabVIEW applications for immediate M Series DAQ use and bridge the gap between test, control, and design applications.
Hybrid-Slot-Compatible PXI ModulesPXI M Series modules are hybrid-slot-compatible so that you can use them in both PXI slots and the hybrid slots found in new PXI Express chassis. The PXI Systems Alliance specifies thathybrid-slot-compatible PXI modules use modified slot connectors to mechanically fit in both PXI slots and hybrid slots. This mechanical change:
Provides compatibility with past, current, and future PXI chassisMaintains existing product specificationsRequires no software changes (application or driver)Maintains speed and capability of all PXI communication (PXI Express signaling is not provided)
However, hybrid-slot-compatible PXI modules do not include the pins used to implement PXI local bus communication, which is used for backplane SCXI control from the right-most PXI slot inPXI/SCXI combination chassis (NI PXI-1010, PXI-1011, PXI-1050, and PXI-1052). For these applications, NI provides unmodified PXI M Series modules that maintain the required local buscapabilities. Refer to the SCXI Control of PXI/SCXI Combination Chassis section in the Ordering Information section for part numbers.
Simultaneous and Intelligent Data AcquisitionWhen you need to obtain performance from a data acquisition device beyond the capabilities of a multifunction data acquisition device, National Instruments provides simultaneous sampling with NIS Series and intelligent data acquisition with NI R Series. The S Series architecture dedicates an analog-to-digital converter (ADC) per channel to provide higher aggregate sampling rates comparedto multiplexed devices. S Series devices are ideal for applications including IF digitization, transient recording, ultrasound and sonar testing, and high-energy physics. R Series multifunction DAQdevices contain a field-programmable gate array (FPGA) that is reconfigurable using the LabVIEW FPGA Module. R Series multifunction devices combine analog input, analog output, and digital I/Oon a single device. You can customize these devices to develop capabilities such as complete control over the synchronization and timing of all signals and operations; user-defined onboarddecision-making logic; and digital lines individually configurable as input, output, counter/timers, pulse-width modulation (PWM), flexible encoder inputs, or user-defined communication protocols.
Industrial M SeriesWhen you need performance and accuracy from a data acquisition device in an electrically noisy or harsh environment, consider industrial NI M Series devices. They offer a set of high-reliabilityfeatures, including isolation, 20 mA current I/O, 24 V digital logic levels, and digital debounce filters. Isolation prevents ground loops, rejects high common-mode voltages, and protects users andequipment from high-voltage transients. Four to 20 mA current loops are immune to most sources of electrical noise and voltage (IR) drops along extensive cable lengths. Sourcing or sinking 24 Vdigital I/O interfaces directly with pumps, valves, relays, and other industry-standard sensors and actuators; programmable debounce filters remove glitches and spikes from switches and relaysconnected to digital input lines.
Recommended AccessoriesSignal conditioning is required for sensor measurements or voltage inputs greater than 10 V. NI SCXI is a versatile, high-performance signal conditioning platform optimized for high-channel-countapplications. NI SCC provides portable, flexible signal conditioning options on a per-channel basis. Visit ni.com/sigcon for NI signal conditioning resources. The NI PCI-6221 (37-Pin) offers a 37-pinD-Sub connector that lowers connectivity costs by 80 percent. The D-Sub connector makes the PCI-6221 (37-Pin) ideal for OEM applications; however, its connector is not compatible with SCC orSCXI signal conditioning.
Recommended Driver SoftwareNational Instruments measurement services software, built around NI-DAQmx driver software, includes intuitive application programming interfaces, configuration tools, I/O assistants, and other toolsdesigned to reduce system setup, configuration, and development time. National Instruments recommends using the latest version of NI-DAQmx driver software for application development in NILabVIEW and LabWindows/CVI, ANSI C/C++, C#, Visual Basic .NET, and Visual Basic 6.0. To download the most recent version of NI-DAQmx software, visit ni.com/support/daq/versions. Linuxand Mac OS X users can program M Series devices with NI-DAQmx Base driver software. M Series devices are compatible with the following versions (or later) of NI application software LabVIEW,LabWindows/CVI, or Measurement Studio versions 7.x; LabVIEW SignalExpress 1.x; VI Logger 2.0; or LabVIEW with the LabVIEW Real-Time Module 7.1. M Series devices are not compatible withthe Traditional NI-DAQ (Legacy) driver.
NI measurement services software speeds up your development with features including the following:
A guide to create fast and accurate measurements with no programming using the DAQ AssistantAutomatic code generation to create your application in LabVIEW; LabWindows/CVI; LabVIEW SignalExpress; and C#, Visual Studio .NET, ANSI C/C++, or Visual Basic using Measurement StudioMultithreaded streaming technology for 1,000 times performance improvementsAutomatic timing, triggering, and synchronization routing to make advanced applications easyThousands of free software downloads available at ni.com/zone to jump-start your project
3/19 www.ni.com
Back to Top
Back to Top
Back to Top
Software configuration of all digital I/O features without hardware switches/jumpersSingle programming interface for analog input, analog output, digital I/O, and counters on hundreds of multifunction DAQ hardware devices
M Series devices are compatible with the following versions (or later) of NI application software LabVIEW, LabWindows/CVI, or Measurement Studio versions 7.x; and LabVIEW SignalExpress 2.x.
Ordering InformationFor a complete list of accessories, visit the product page on ni.com.
Software Recommendations
LabVIEW ProfessionalDevelopment System forWindows
Advanced software tools for large project developmentAutomatic code generation using DAQ Assistant andInstrument I/O AssistantTight integration with a wide range of hardwareAdvanced measurement analysis and digital signalprocessingOpen connectivity with DLLs, ActiveX, and .NET objectsCapability to build DLLs, executables, and MSI installers
NI LabVIEW SignalExpress forWindows
Quickly configure projects without programmingControl over 400 PC-based and stand-alone instrumentsLog data from more than 250 data acquisition devicesPerform basic signal processing, analysis, and file I/OScale your application with automatic LabVIEW codegenerationCreate custom reports or easily export data to LabVIEW,DIAdem or Microsoft Excel
NI LabWindows/CVI forWindows
Real-time advanced 2D graphs and chartsComplete hardware compatibility with IVI, VISA, DAQ,GPIB, and serialAnalysis tools for array manipulation, signal processingstatistics, and curve fittingSimplified cross-platform communication with networkvariablesMeasurement Studio .NET tools (included inLabWindows/CVI Full only)The mark LabWindows is used under a license fromMicrosoft Corporation.
NI Measurement StudioProfessional Edition
Customizable graphs and charts for WPF, WindowsForms, and ASP.NET Web Forms UI designAnalysis libraries for array operations, signal generation,windowing, filters, signal processingHardware integration support with native .NET dataacquisition and instrument control librariesAutomatic code generation for all NI-DAQmx dataacquisition hardwareIntelligent and efficient data-logging libraries forstreaming measurement data to diskSupport for Microsoft Visual Studio .NET 2012/2010/2008
Support and ServicesSystem Assurance Programs
NI system assurance programs are designed to make it even easier for you to own an NI system. These programs include configuration and deployment services for your NI PXI, CompactRIO, orCompact FieldPoint system. The NI Basic System Assurance Program provides a simple integration test and ensures that your system is delivered completely assembled in one box. When youconfigure your system with the NI Standard System Assurance Program, you can select from available NI system driver sets and application development environments to create customized,reorderable software configurations. Your system arrives fully assembled and tested in one box with your software preinstalled. When you order your system with the standard program, you alsoreceive system-specific documentation including a bill of materials, an integration test report, a recommended maintenance plan, and frequently asked question documents. Finally, the standardprogram reduces the total cost of owning an NI system by providing three years of warranty coverage and calibration service. Use the online product advisors at ni.com/advisor to find a systemassurance program to meet your needs.
Calibration
NI measurement hardware is calibrated to ensure measurement accuracy and verify that the device meets its published specifications. To ensure the ongoing accuracy of your measurementhardware, NI offers basic or detailed recalibration service that provides ongoing ISO 9001 audit compliance and confidence in your measurements. To learn more about NI calibration services or tolocate a qualified service center near you, contact your local sales office or visit ni.com/calibration.
Technical Support
Get answers to your technical questions using the following National Instruments resources.
Support - Visit ni.com/support to access the NI KnowledgeBase, example programs, and tutorials or to contact our applications engineers who are located in NI sales offices around the worldand speak the local language.Discussion Forums - Visit forums.ni.com for a diverse set of discussion boards on topics you care about.Online Community - Visit community.ni.com to find, contribute, or collaborate on customer-contributed technical content with users like you.
Repair
While you may never need your hardware repaired, NI understands that unexpected events may lead to necessary repairs. NI offers repair services performed by highly trained technicians whoquickly return your device with the guarantee that it will perform to factory specifications. For more information, visit ni.com/repair.
Training and Certifications
4/19 www.ni.com
Back to Top
The NI training and certification program delivers the fastest, most certain route to increased proficiency and productivity using NI software and hardware. Training builds the skills to more efficientlydevelop robust, maintainable applications, while certification validates your knowledge and ability.
Classroom training in cities worldwide - the most comprehensive hands-on training taught by engineers.On-site training at your facility - an excellent option to train multiple employees at the same time.Online instructor-led training - lower-cost, remote training if classroom or on-site courses are not possible.Course kits - lowest-cost, self-paced training that you can use as reference guides.Training memberships and training credits - to buy now and schedule training later.
Visit ni.com/training for more information.
Extended Warranty
NI offers options for extending the standard product warranty to meet the life-cycle requirements of your project. In addition, because NI understands that your requirements may change, theextended warranty is flexible in length and easily renewed. For more information, visit ni.com/warranty.
OEM
NI offers design-in consulting and product integration assistance if you need NI products for OEM applications. For information about special pricing and services for OEM customers, visitni.com/oem.
Alliance
Our Professional Services Team is comprised of NI applications engineers, NI Consulting Services, and a worldwide National Instruments Alliance Partner program of more than 700 independentconsultants and integrators. Services range from start-up assistance to turnkey system integration. Visit ni.com/alliance.
Detailed SpecificationsSpecifications listed below are typical at 25 C unless otherwise noted. Refer to the for more information about NI 622 devices.M Series User Manual x
Analog Input
Number of channels
NI 6220/6221 8 differential or 16 single ended
NI 6224/6229 16 differential or 32 single ended
NI 6225 40 differential or 80 single ended
ADC resolution 16 bits
DNL No missing codes guaranteed
INL Refer to the AI Absolute Accuracy Table
Sampling rate
Maximum 250 kS/s single channel,250 kS/s multi-channel (aggregate)
Minimum No minimum
Timing accuracy 50 ppm of sample rate
Timing resolution 50 ns
Input coupling DC
Input range 10 V, 5 V, 1 V, 0.2 V
Maximum working voltage for analog inputs (signal + common mode) 11 V of AI GND
CMRR (DC to 60 Hz) 92 dB
Input impedance
Device on
AI+ to AI GND >10 G in parallel with 100 pF
AI- to AI GND >10 G in parallel with 100 pF
Device off
AI+ to AI GND 820
AI- to AI GND 820
Input bias current 100 pA
Crosstalk (at 100 kHz)
Adjacent channels -75 dB
5/19 www.ni.com
Non-adjacent channels -90 dB1
Small signal bandwidth (-3 dB) 700 kHz
Input FIFO size 4,095 samples
Scan list memory 4,095 entries
Data transfers
PCI/PXI devices DMA (scatter-gather), interrupts, programmed I/O
USB devices USB Signal Stream, programmed I/O
Overvoltage protection (AI , AI SENSE, AI SENSE 2)
Device on 25 V for up to two AI pins
Device off 15 V for up to two AI pins
Input current during overvoltage condition 20 mA max/AI pin
1 For USB-6225 devices, channel AI crosstalk to channel AI is -71 dB; applies to channels with 64-channel separation, for example, AI ( ) and AI ( + 64).x x
Settling Time for Multichannel Measurements
Accuracy, full scale step, all ranges
90 ppm of step (6 LSB) 4 s convert interval
30 ppm of step (2 LSB) 5 s convert interval
15 ppm of step (1 LSB) 7 s convert interval
Typical Performance Graphs
Analog Output
Number of channels
NI 6220/6224 0
NI 6221/6225 2
NI 6229 4
6/19 www.ni.com
DAC resolution 16 bits
DNL 1 LSB
Monotonicity 16 bit guaranteed
Maximum update rate
1 channel 833 kS/s
2 channels 740 kS/s per channel
3 channels 666 kS/s per channel
4 channels 625 kS/s per channel
Timing accuracy 50 ppm of sample rate
Timing resolution 50 ns
Output range 10 V
Output coupling DC
Output impedance 0.2
Output current drive 5 mA
Overdrive protection 25 V
Overdrive current 10 mA
Power-on state 20 mV2
Power-on glitch 400 mV for 200 ms
Output FIFO size 8,191 samples shared among channels used
Data transfers
PCI/PXI devices DMA (scatter-gather), interrupts, programmed I/O
USB devices USB Signal Stream, programmed I/O
AO waveform modes:
Non-periodic waveformPeriodic waveform regeneration mode from onboard FIFOPeriodic waveform regeneration from host buffer including dynamic update
Settling time, full scale step 15 ppm (1 LSB) 6 s
Slew rate 15 V/s
Glitch energy
Magnitude 100 mV
Duration 2.6 s
2 For all USB-6221/6229 Screw Terminal devices, when powered on, the analog output signal is not defined until after USB configuration is complete.
Calibration (AI and AO)
Recommended warm-up time 15 minutes
Calibration interval 1 year
AI Absolute Accuracy Table
Nominal Range ResidualGainError
(ppm ofReading)
GainTempco(ppm/C)
ReferenceTempco
ResidualOffsetError
(ppm ofRange)
OffsetTempco(ppm of
Range/C)
INL Error(ppm ofRange)
RandomNoise,
(Vrms)
AbsoluteAccuracy
atFull
Scale (V)1
Sensitivity2
(V)
PositiveFull
Scale
NegativeFull
Scale
10 -10 75 25 5 20 57 76 244 3,100 97.65 -5 85 25 5 20 60 76 122 1,620 48.81 -1 95 25 5 25 79 76 30 360 12.0
0.2 -0.2 135 25 5 80 175 76 13 112 5.2
AbsoluteAccuracy = Reading (GainError) + Range (OffsetError) + NoiseUncertainty
GainError = ResidualAIGainError + GainTempco (TempChangeFromLastInternalCal) + ReferenceTempco (TempChangeFromLastExternalCal)
OffsetError = ResidualAIOffsetError + OffsetTempco (TempChangeFromLastInternalCal) + INL_Error
7/19 www.ni.com
1 Absolute accuracy at full scale on the analog input channels is determined using the following assumptions:
TempChangeFromLastExternalCal = 10 C
TempChangeFromLastInternalCal = 1 C
number_of_readings = 100
CoverageFactor = 3
For example, on the 10 V range, the absolute accuracy at full scale is as follows:
GainError = 75 ppm + 25 ppm 1 + 5 ppm 10 GainError = 150 ppm
OffsetError = 20 ppm + 57 ppm 1 + 76 ppm OffsetError = 153 ppm
AbsoluteAccuracy = 10 V (GainError) + 10 V (OffsetError) + NoiseUncertainty AbsoluteAccuracy = 3,100 V
2 Sensitivity is the smallest voltage change that can be detected. It is a function of noise.
Accuracies listed are valid for up to one year from the device external calibration.
AO Absolute Accuracy Table
Nominal RangeResidual
Gain Error(ppm of
Reading)
GainTempco(ppm/C)
ReferenceTempco
ResidualOffset Error
(ppm ofRange)
OffsetTempco(ppm of
Range/C)
INLError
(ppm ofRange)
AbsoluteAccuracy at
FullScale1
(V)
PositiveFull
Scale
NegativeFull
Scale
10 -10 90 10 5 40 5 128 3,230
1 Absolute Accuracy at full scale numbers is valid immediately following internal calibration and assumes the device is operating within 10 C of the last externalcalibration. Accuracies listed are valid for up to one year from the device external calibration.
AbsoluteAccuracy = OutputValue (GainError) + Range (OffsetError)
GainError = ResidualGainError + GainTempco (TempChangeFromLastInternalCal) + ReferenceTempco (TempChangeFromLastExternalCal)
OffsetError = ResidualOffsetError + AOOffsetTempco (TempChangeFromLastInternalCal) + INL_Error
Digital I/O/PFI
Static Characteristics
Number of channels
NI 6220/6221 (68-pin)/6225 24 total8 (P0.) 16 (PFI /P1, PFI /P2)
PCI-6221 (37-pin) 10 total2 (P0.) 8 (PFI /P1)
NI 6224/6229 48 total32 (P0.) 16 (PFI /P1, PFI /P2)
Ground reference D GND
Direction control Each terminal individually programmable as input or output
Pull-down resistor 50 k typical, 20 k minimum
Input voltage protection3 20 V on up to two pins
3 Stresses beyond those listed under may cause permanent damage to the device.Input voltage protection
Waveform Characteristics (Port 0 Only)
Terminals used
NI 6220/6221 (68-pin)/6225 Port 0 (P0.)
PCI-6221 (37-pin) Port 0 (P0.)
NI 6224/6229 Port 0 (P0.)
Port/sample size
NI 6220/6221 (68-pin)/6225 Up to 8 bits
8/19 www.ni.com
PCI-6221 (37-pin) Up to 2 bits
NI 6224/6229 Up to 32 bits
Waveform generation (DO) FIFO 2,047 samples
Waveform acquisition (DI) FIFO 2,047 samples
DI or DO Sample Clock frequency4 0 to 1 MHz
Data transfers
PCI/PXI devices DMA (scatter-gather), interrupts, programmed I/O
USB devices USB Signal Stream, programmed I/O
DO or DI Sample Clock source5 Any PFI, RTSI, AI Sample or Convert Clock, AO Sample Clock, Ctr Internal Output, andnmany other signals
4 Performance can be dependent on bus latency and volume of bus activity. The digital subsystem does not have its own dedicated internal timing engine. Therefore, a sample clock must be provided from another subsystem on the device or an external source.5
PFI/Port 1/Port 2 Functionality6
Functionality Static digital input, static digital output, timing input, timing output
Timing output sources Many AI, AO, counter, DI, DO timing signals
Debounce filter settings 125 ns, 6.425 s, 2.56 ms, disable; high and low transitions; selectable per input
6 Port 2 is not available on PCI-6221 (37-pin) devices.
Recommended Operation Conditions, PCI/PXI Devices
Level Min Max
Input high voltage (V )IH 2.2 V 5.25 VInput low voltage (V )IL 0 V 0.8 VOutput high current (I )OH P0. PFI /P1/P2
-24 mA-16 mA
Output low current (I )OL P0. PFI /P1/P2
24 mA16 mA
Recommended Operation Conditions, USB Devices
Level Min Max
Input high voltage (V )IH 2.2 V 5.25 VInput low voltage (V )IL 0 V 0.8 VOutput high current (I )OH P0. P0. PFI /P1/P2
-24 mA-16 mA-16 mA
Output low current (I )OL P0. P0. PFI /P1/P2
24 mA16 mA16 mA
Electrical Characteristics
Level Min Max
Positive-going threshold (VT+)Negative-going threshold (VT-)
0.8 V
2.2 V
Delta VT hysteresis (VT+ - VT-) 0.2 V
I input low current (V = 0 V)IL in
I input high current (V = 5 V)IH in
-10 A
250 A
Digital I/O Characteristics6
9/19 www.ni.com
General-Purpose Counter/Timers
Number of counter/timers 2
Resolution 32 bits
Counter measurements Edge counting, pulse, semi-period, period, two-edge separation
Position measurements X1, X2, X4 quadrature encoding with Channel Z reloading; two-pulse encoding
Output applications Pulse, pulse train with dynamic updates, frequency division, equivalent time sampling
Internal base clocks 80 MHz, 20 MHz, 0.1 MHz
External base clock frequency 0 MHz to 20 MHz
Base clock accuracy 50 ppm
Inputs Gate, Source, HW_Arm, Aux, A, B, Z, Up_Down
Routing options for inputs Any PFI, RTSI, PXI_TRIG, PXI_STAR, analog trigger, many internal signals
FIFO 2 samples
Data transfers
PCI/PCIe/PXI/PXIe devices Dedicated scatter-gather DMA controller for each counter/timer; interrupts, programmedI/O
USB devices USB Signal Stream, programmed I/O
Frequency Generator
Number of channels 1
Base clocks 10 MHz, 100 kHz
Divisors 1 to 16
Base clock accuracy 50 ppm
Output can be available on any PFI or RTSI terminal.
10/19 www.ni.com
Phase-Locked Loop (PLL)
Number of PLLs 1
Reference signal PXI_STAR, PXI_CLK10, RTSI
Output of PLL 80 MHz Timebase; other signals derived from 80 MHz Timebase including 20 MHz and100 kHz Timebases
External Digital Triggers
Source Any PFI, RTSI, PXI_TRIG, PXI_STAR
Polarity Software-selectable for most signals
Analog input function Start Trigger, Reference Trigger, Pause Trigger, Sample Clock, Convert Clock, SampleClock Timebase
Analog output function Start Trigger, Pause Trigger, Sample Clock, Sample Clock Timebase
Counter/timer functions Gate, Source, HW_Arm, Aux, A, B, Z, Up_Down
Digital waveform generation (DO) function Sample Clock
Digital waveform acquisition (DI) function Sample Clock
Device-To-Device Trigger Bus
PCI/PCIe devices RTSI 7
PXI/PXIe devices PXI_TRIG , PXI_STAR
USB devices None
Output selections 10 MHz Clock; frequency generator output; many internal signals
Debounce filter settings 125 ns, 6.425 s, 2.56 ms, disable; high and low transitions; selectable per input
7 In other sections of this document, refers to RTSI for PCI devices or PXI_TRIG for PXI devices.RTSI
Bus Interface
PCI/PXI devices 3.3 V or 5 V signal environment
USB devices USB 2.0 Hi-Speed or full-speed8
DMA channels (PCI/PXI devices) 6, analog input, analog output, digital input, digital output, counter/timer 0, counter/timer 1
USB Signal Stream (USB devices) 4, can be used for analog input, analog output, digital input, digital output, counter/timer 0,counter/timer 1
All PXI-625x devices support one of the following features:
May be installed in PXI Express hybrid slotsOr, may be used to control SCXI in PXI/SCXI combo chassis
8 If you are using a USB M Series device in full-speed mode, device performance will be lower and you will not be able to achieve maximum sampling/update rates.
Table 1. PXI/SCXI Combo and PXI Express Chassis CompatibilityM Series Device M Series Part Number SCXI Control in PXI/SCXI Combo Chassis PXI Express Hybrid Slot Compatible
PXI-6220 191332B-04 No Yes
PXI-6221191332B-03 No Yes191332B-13 Yes No
PXI-6224 191332B-02 No YesPXI-6225 192227A-01 No Yes
PXI-6229191332B-01 No Yes191332B-11 Yes No
Earlier versions of PXI-6220/6221/6224/6229 191332A-0x Yes No
Power Requirements
Current draw from bus during no-load condition9
PCI/PXI devices
+5 V 0.02 A10
+3.3 V 0.25 A10
+12 V 0.15 A
Current draw from bus during AI and AO overvoltage condition9
11/19 www.ni.com
PCI/PXI devices
+5 V 0.02 A10
+3.3 V 0.25 A10
+12 V 0.25 A
Caution USB-622 devices must be powered with NI offered AC adapter or a National Electric Code (NEC) Class 2 DC source that meets the power requirementsxfor the device and has appropriate safety certification marks for country of use.
USB power supply requirements 11 to 30 VDC, 20 W, locking or non-locking power jack with 0.080" diameter center pin,5/16-32 thread for locking collars
9 Does not include P0/PFI/P1/P2 and +5 V terminals. PCI-6221 (37-pin) devices do not use +3.3 V from the bus. The 3.3 V current draw, shown in the section, comes from the +5 V instead.10 Power Requirements
Power Limits
Caution Exceeding the power limits may cause unpredictable behavior by the device and/or PC/chassis.
PCI devices
+5 V terminal (connector 0) 1 A max11
+5 V terminal (connector 1) 1 A max11
PXI devices
+5 V terminal (connector 0) 1 A max11
+5 V terminal (connector 1) 1 A max11
P0/PFI/P1/P2 and +5 V terminals combined 2 A max
USB devices
+5 V terminal 1 A max11
P0/PFI/P1/P2 and +5 V terminals combined 2 A max
Power supply fuse 2 A, 250 V
11 Has a self-resetting fuse that opens when current exceeds this specification.
Physical Requirements
Printed circuit board dimensions
PCI-6220/6221/6224/6225/6229 9.7 x 15.5 cm (3.8 x 6.1 in.)
PXI-6220/6221/6224/6225/6229 Standard 3U PXI
Enclosure dimensions (includes connectors)
USB-6221/6225/6229 Screw Terminal 26.67 x 17.09 x 4.45 cm (10.5 x 6.73 x 1.75 in.)
USB-6221/6229 BNC 28.6 x 17 x 6.9 cm (11.25 x 6.7 x 2.7 in.)
USB-6225 Mass Termination 18.8 x 17.09 x 4.45 cm (7.4 x 6.73 x 1.75 in.)
USB-6221/6225/6229 OEM Refer to the NI USB-622x/625x OEM User Guide
Weight
PCI-6220 91 g (3.2 oz)
PCI-6221 (68-pin) 92 g (3.2 oz)
PCI-6221 (37-pin) 95 g (3.3 oz)
PCI-6224 99 g (3.5 oz)
PCI-6225 103 g (3.6 oz)
PCI-6229 101 g (3.5 oz)
PXI-6220 158 g (5.5 oz)
PXI-6221 162 g (5.7 oz)
PXI-6224 170 g (5.9 oz)
PXI-6225 174 g (6.1 oz)
PXI-6229 171 g (6.0 oz)
USB-6221 Screw Terminal 1.2 kg (2 lb 10 oz)
12/19 www.ni.com
USB-6225/6229 Screw Terminal 1.24 kg (2 lb 11 oz)
USB-6225 Mass Termination 907 g (2 lb)
USB-6221 OEM 131 g (4.6 oz)
USB-6225/6229 OEM 162 g (5.7 oz)
I/O connector
PCI/PXI-6220/6221 (68-pin) 1 68-pin VHDCI
PCI/PXI-6224/6225/6229 2 68-pin VHDCI
PCI-6221 (37-pin) 1 37-pin D-SUB
USB-6221 Screw Terminal 64 screw terminals
USB-6225/6229 Screw Terminal 128 screw terminals
USB-6221 BNC 21 BNCs and 30 screw terminals
USB-6229 BNC 32 BNCs and 60 screw terminals
USB-6225 Mass Termination 2 68-pin SCSI
USB-6221/6225/6229 Screw Terminal/USB-6221/6229 BNC screw terminal wiring 16-28 AWG
Maximum Working Voltage12
NI 6220/6221/6224/6225/6229 channel-to-earth 11 V, Measurement Category I
Caution Do use for measurements within Categories II, III, or IV.not
12 refers to the signal voltage plus the common-mode voltage.Maximum working voltage
Environmental
Operating temperature
PCI/PXI devices 0 to 55 C
USB devices 0 to 45 C
Storage temperature -20 to 70 C
Humidity 10 to 90% RH, noncondensing
Maximum altitude 2,000 m
Pollution Degree (indoor use only) 2
Shock and Vibration (PXI Devices Only)
Operational shock 30 g peak, half-sine, 11 ms pulse(Tested in accordance with IEC-60068-2-27. Test profile developed in accordance withMIL-PRF-28800F.)
Random vibration
Operating 5 to 500 Hz, 0.3 grms
Nonoperating 5 to 500 Hz, 2.4 grms(Tested in accordance with IEC-60068-2-64. Nonoperating test profile exceeds therequirements of MIL-PRF-28800F, Class 3.)
Safety
This product is designed to meet the requirements of the following standards of safety for electrical equipment for measurement, control, and laboratory use:
IEC 61010-1, EN 61010-1UL 61010-1, CSA 61010-1
Note For UL and other safety certifications, refer to the product label or visit ni.com/certification, search by model number or product line, and click the appropriate link in theCertification column.
Electromagnetic Compatibility
This product is designed to meet the requirements of the following standards of EMC for electrical equipment for measurement, control, and l